Sunteți pe pagina 1din 11

Laundry Design The laundry is designed to cater to 240 rooms and other allied services Shift- 2 Shift Basis

General Laundry Scope Room Linen F&B Staff Uniforms Guest Linen TECHNICAL SPECIFICATION GENERAL AND SPECIFIC Washer Extractors The washer extractors shall be heavy duty industrial design for long life. All parts in connection with water must be of minimum SS304 grade stainless steel like cylinder shell, shell door, basket, shaft etc. The basic design of machines shall be of SOFT MOUNT having either suspended or shocker/ air float based drum design to eliminate maximum vibration, the maximum permissible vibration to pass to the ground is not more than 5%. The machine shall have HIGH G Force of 300 plus The minimum number of wash/extract speed is 5 and machine should have possibility of intermediate extract. Machine shall minimum 3 or 5 ( depending upon capacity of machine) flushing supply injection system combined with manual hoppers and facility for minimum of 5 outer signal for liquid dosing The machine shall have single motor AC drive only The machine should have minimum 3 water level control, preferably 5 level The machine should have self diagnostic and emergency stop button The machine shall have pneumatic door interlock to prevent accidental start of machine unless the door is closed and also facility of no door opening unless inner drum has come to an complete halt The machine shall have automatic temp control, water control through pneumatic valves The machine should have large inlet and drain for water for quick filling and discharge, all automatically controlled The machine should have possibly a security code system to prevent unauthorised access to control panel The loading door must be adequately sized as per BOQ for easy unloading and loading

Specific Technical Details for washer extractor 225 WASHER EXTRACTOR- preferred make Edro Dyna Wash or equivalent Model- CSl225 or equivalent Front end loading and unloading Washer extractor with large door, open pocket, option of one way tilting, PLC control ; single motor inverter drive with field Programmable speeds; 380-4400/3/50 electrical; 5-compartment flushing supply with 5 liquid signals; stainless steel panels and trim standard commercial packaging SPECS Dry Weight Capacity: Cylinder Dimensions: Cylinder Volume: Door Opening: Water Inlets (H&C): Steam Inlet: Motor Rating Drain Pipe: Circuit Breaker @ 480/3/60 Frequency Drive: Speeds: G-Force (at high extract): 225 lbs. / 103 kg. 49 in. x 33 in. 35.9 ft.3 / 1016 liters 25 in. diameter 2 in. NPT 1-1/2 in. NPT 20 hp 2 @ 5 in. Diameter 50 amp single motor 6 up to 300

110 WASHER EXTRACTOR- preferred make Edro Dyna Wash or equivalent Model- CSl110 or equivalent Front end loading and unloading Washer extractor with large door, open pocket, option of one way tilting, PLC control ; single motor inverter drive with field Programmable speeds; 380-4400/3/50 electrical; 5-compartment flushing supply with 5 liquid signals; stainless steel panels and trim standard commercial packaging SPECS Dry Weight Capacity: Cylinder Dimensions: Cylinder Volume: Door Opening: Water Inlets (H&C): Steam Inlet: Drain Pipe: Motor RATING Circuit Breaker @ 480/3/60 Frequency Drive: 110 lbs. / 50 kg. 39 in. x 26 in. 17.9 ft.3 / 506 liters 20-1/4 in. diameter 2 in. NPT 1-1/2 in. NPT 2 @ 5 in. diameter 1O HP 50 amp single motor

Speed G Force

6 up to 300

60 WASHER EXTRACTOR- preferred make Edro Dyna Wash or equivalent Model- CSL-60 or equivalent Front end loading and unloading Washer extractor with large door, open pocket, option of one way tilting, PLC control ; single motor inverter drive with field Programmable speeds; 380-4400/3/50 electrical; 3-compartment flushing supply with 5 liquid signals; stainless steel panels and trim standard commercial packaging SPECS Dry Weight Capacity: Cylinder Dimensions: Cylinder Volume: Door Opening: Water Inlets (H&C): Steam Inlet: Drain Pipe: Motor Rating Circuit Breaker @ 480/3/60 Frequency Drive: Speeds: G-Force (at high extract): 60 lbs. / 103 kg. 32 in. x 20 in. 9.3 ft.3 / 265 liters 17 in. diameter . NPT 1-1/2 in. NPT 1 @ 4 in. diameter 7.5 hp 50 amp single motor 6 up to 300

Dryer The dryer should be of industrial design The inner drum must be of stainless steel of 304 grade The inner drum should have a loading ratio of minimum 1:20 The heat exchanger must have robust and strong construction The machine should have PLC control with facility for flexible programming for cycle time, temp and residual moisture The machine should have pneumatic flap for cool down cycle to allow only ambient air to flow in dryer drum The drive system of dryer must be of robust construction and heavy duty , shall have minimum 5 year warranty of frame and drum, drum shaft The dryer should have option of heat recovery system for the exhaust hot air

The motors of dryer must have thermal over load protection as standard

120 Lbs Dryer Model- CRT-120 or equivalent Capacity120 lbs 1181 mm 1651 mm 2172mm 1041 mm 1118 mm 1041 liters 683 mm 1:20- 50 Kg 1600

Width - in (mm)Depth - in (mm)Height - in (mm)Cylinder Depth Cylinder Diameter Cylinder Volume Door Opening Dry Capacity FillingAirflow cfm/liters-

Water Inlet Size in-CARE/SAFEElectrical Specs- 380-440/50/3 Plumbing connections- NPT 75 Lbs Dryer Model- CRT 75 or equivalent Capacity75 lbs 981 mm

Width - in (mm)-

Depth - in (mm)Height - in (mm)Cylinder Depth Cylinder Diameter Cylinder Volume Door Opening Dry Capacity FillingAirflow cfm/liters-

1346 mm 1946 mm 914 mm 939 mm 690 liters 683 mm 1:20- 35 Kg 920

Water Inlet Size in-CARE/SAFEElectrical Specs- 380-440/50/3 Plumbing connections- NPT

Flat work Ironer- preferred make- Kannegiesser Model- SHM8-33-2 or equivalent The flat work ironer shall be of industrial design use The flat work Ironer shall following general features The roller is of 800 mm diameter and roller length is 3300 mm and number of roller -2 Nos The chest of the ironer must be designed to provide continuous stable support to the rollers The chest should have reinforced ribs The chest must be highly polished with roughness value up to 2 um for high quality linen finish and better heat transfer ratio The rollers must be almost completely perforated

The roller must raise and lower vertically exactly in the chest to get perfect and uniform pressure all over the pressing area The drive should be variable drive with three phase supply The steam and condensate pipes must be properly insulated There should be a central exhaust pump The ironer must have over head canopy which must be heat proof to avoid heat loss The ironer must have temperature regulation system The Ironer should have heat recovery system in the exhaust The ironer should have a display of all working conditions to the operator The ironer should have manual over ride in case of emergency The ironer must have a safety lock switch for maintenance job and also rollers must be locked physically while in raised position while doing ay repair job on ironer and it should have finger safety guard for feeding side The ironer should have 4 emergency stops at four corners of the ironer

2 Roller Ironer Specs working width: 3300 mm no. of rolls: 2 diameter of rolls: 800 mm Standard: - Chest roll unit with direct control of rolls - Two lever support of rolls for even ironing pressure on the complete chest surface for high evaporation capacity - Automatic torque compensation for consistent roll pressure independent from drive torque - Steam heated bridge - Service Lifting device each roll for maintenance - outlet plate - ironer tape guidance - emergency stop buttons (2 on feeding and 2 on outlet side) - railing over walk way and bridge roll padding: galvanized round spring with polyester needle felt - Steam heated drive: AC motor with frequency converte

Dry Cleaning Machine

Dry Cleaning Machine shall be PERC basedThe machine shall have a three self cleaning solvent tank system with 2 Nylon filters The machine shall have inbuilt high speed extraction The machine shall be PLC operated The machine shall have inbuilt refrigeration unit with water The machine shall have a solvent safety trough Button trap All important parts made of SS 304 TECHNICAL INFORMATION WORKING MACHINE WITH SOLVENT: PERCHLORETHYLENE MACHINE CAPACITY (RATIO 1:20) Model- RS15 or equivalent => BASKET Diameter 800 Depth 400 Wash speed rpm 40 Extract speed rpm 385 Door opening mm 500 => SOLVENT TANKS Useful volume tank 1 Lt 275 Useful volume tank 2 Lt 145 Useful volume tank 3 Volume Lt 200 => FLOOR SAFETY TANK CAPACITY => DESTILLATOR Useful volume at half inspection Lt 145 Total volume Lt 180 Boiler water capacity 5.5 Lt => ELECTRIC POWER (400 V - 50 Hz) Wash motor- .3 Kw Extract motor- 1.3 Kw Solvent pump motor-.5 kw Fan motor-.75 kw

Refrigerator motor- 2.5 kw Nylon filter motor- .55 kw Exsaust fan motor- .14 kw Air motor compressor- .37 kw

Presses- preferred make- Unipress or equivalent The presses are an important aspect of high quality guest garment and uniform finishing Dry-cleaning Utility Press- the DC press should have Durable construction Made for automatic/Manual operation Two button control PLC and timer control Single Action cylinders Finger tip pressure High quality Mesh and padding Buck size of 46 inches length 46 inch DC Utility Legger- Preferred make Unipress or equivalent Model- 46X or equivalent 19 inch DC Mushroom Utility Press- Preferred make Unipress or equivalent Model- 19MX or equivalent Form Finisher- Preferred make Unipress or equivalent Model- ASF or equivalent Spotting Machine- Preferred make- Unipress or equivalent Model- SST Specifications

Drycleaning Press Specifications


Air Steam Steam Steam Vacuum Air Air Volume Ship Heat Heat Model BHP Electrical Supply Inlet Outlet Outlet Inlet Supply Per Wt. BTU Rad. Cycle 46X 85 psi 1/2" 1/2" (2) 1/2" (2) 1 1/4" 1 1/4" 3/8" 85 psi 1/2 cu. ft. 1 1 115/1/60 825 5000 1.5 lbs.

19MX 85 psi

3/8" 85 PSI 1/2 cu.

115/1/60 675 2850 0.8

1/2" ASF SST 85 psi 85 psi 1/2" 1/2" 1/2" 1/2" N/A 1 1/4" N/A N/A

ft. N/A N/A

lbs. 280 2 115/1/60 lbs. 3500 1.0 1 N/A 280 2500 0.7 lbs.

1/2" 80 PSI

Cotton Hot Head presses- Preferred make Unipress or equivalent Highly Polished Plated Head. Smooth Operation. Microprocessor Controls with Self Diagnostics. High Pressure Squeeze Cylinder. Rugged construction. Two Hand Safety Control. 51 inch Cotton Hot Head press- Preferred make Unipress or equivalent Model- SLZ or equivalent 19 inch Cotton Hot Head Press- Preferred make Unipress or equivalent Model- FMT or equivalent Collar and Cuff press- Preferred make Unipress or equivalent Model F3T or equivalent

Laundry Press Specifications


Air Steam Steam Steam Air Air Volume Ship Heat Heat Model BHP Electrical Supply Inlet Outlet Inlet Supply Per Wt. BTU Rad. Cycle SLZ 125 psi 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 85 psi 3/8" 85 psi 3/8" 85 psi 1.75 cu. 1100 .75 115/1/60 8535 ft. lbs. 1.75 cu. 1050 .75 115/1/60 7875 ft lbs. 1cu. ft .25 115/1/60 115/1/60 580 1700 lbs. 2.5 2.3 0.5 1.3

WAZ 125 psi FMT 125 psi

F3T 125 psi 3/8" (2) 3/8" 3/8" 85 psi 1 cu. ft. .75

800 lbs. 4750

Laundry Shelves: Mobile linen shelves shall be 550 wide with 4 nos fixed shelves at 30 mm. The stand shall be fabricated from tubular stainless steel with 125-150 dia swivelling wheels. Each shelf shall be capable of carrying a load of 250 kg.. Shelves shall be of stainless steel to SS 304 Quality. Storage shelves shall be 500mm wide made of stainless steel tubular with 4 nos shelves at about 330 mm centre to centre. Shelves shall be capable of carrying 400 kg every 1250 mm length. All storage shelves and stand shall be of stainless steel to SS 304 Quality. Laundry Trolleys: Dry linen trolleys shall be of fibre reinforced plastic with side and bottom openings for breathing. The trolleys shall be approximately 850 x 600 x 550 with four swivelling wheels Wet linen trolleys shall be approximately 800 x 600 x 750 with four swivelling wheels on a stainless steel frame with fibre reinforced plastic container. Hand Irons: Hand irons shall be hand operated electric irons. . The ironing boards shall be portable and complete with 1100 x 550 x 850 table with 2 nos 250 x 400 x 250 shelves with hinged shutter.

Installation Installation of piping shall be carried out in a professional manner, all installation ,material must be quoted by vendor giving complete BOQ with make of material and rate on prorate basis with warranty for workmanship and for material both, we will provide only services required to the point of consumption. The work must be done in a tidy manner with no loose end sand vendor is responsible for safety of their workman