This document and the software described herein are the property of Ascential Software Corporation and its licensors and contain confidential trade secrets. All rights to this publication are reserved. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language, in any form or by any means, without prior permission from Ascential Software Corporation. Copyright 2002 Ascential Software Corporation. All rights Reserved Ascential Software Corporation reserves the right to make changes to this document and the software described herein at any time and without notice. No warranty is expressed or implied other than any contained in the terms and conditions of sale. Ascential Software Corporation 50 Washington Street Westboro, MA 01581-1021 USA Phone: (508) 366-3888 Fax: (508) 389-8749 Ardent, Axielle, DataStage, Iterations, MetaBroker, MetaStage, and uniVerse are registered trademarks of Ascential Software Corporation. Pick is a registered trademark of Pick Systems. Ascential Software is not a licensee of Pick Systems. Other trademarks and registered trademarks are the property of the respective trademark holder. 09-01-2002

Contents - 3

Contents - 4 Copyright 2002 Ascential Software Corporation Version 6.0: 09/01/02

Table of Contents
Module 1: Introduction to DataStage ............................ 1-01 Module 2: Installing DataStage ..................................... 2-01 Module 3: Configuring Projects ..................................... 3-01 Module 4: Designing and Running Jobs ........................ 4-01 Module 5: Working with Metadata................................. 5-01 Module 6: Working with Relational Data ....................... 6-01 Module 7: Constraints and Derivations .......................... 7-01 Module 8: Creating BASIC Expressions ........................ 8-01 Module 9: Troubleshooting ............................................ 9-01 Module 10: Defining Lookups ...................................... 10-01 Module 11: Aggregating Data ...................................... 11-01 Module 12: Job Control................................................ 12-01 Module 13: Working with Plug-Ins ............................... 13-01 Module 14: Scheduling and Reporting ........................ 14-01 Module 15: Optimizing Job Performance .................... 15-01 Module 16: Putting It All Together .............................. 16-01

Contents - 5

Contents - 6 Copyright 2002 Ascential Software Corporation Version 6.0: 09/01/02

Module 1

Introduction to DataStage

Module 1 Introduction to DataStage

DataStage 314Svr

Ascential software provides the enterprise with a full featured data integration platform that can take data from any source and load it into any target. Sources can range from customer relationship systems to legacy systems to data warehouses -- in fact, any system that houses data. Target systems, likewise, can consist of data in warehouses, real-time systems, Web services -- any application that houses data. Depending on your needs, source data can undergo scrutiny and transformation through several stages: 1. Data profiling -- a discovery process where relevant information for target enterprise applications is gathered 2. Data quality -- a preparation process where data can be cleansed and corrected 3. Extract, Transform, Load -- a transformation process where data is enriched and loaded into the target Underlying these processes is an application framework that allows you to 1. Utilize parallel processing for maximum performance 2. Manage and share metadata amongst all the stages Overlaying all of this is a command and control structure that allows you to tailor your environment to your specific needs.
1-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

1-3

Module 1 Introduction to DataStage

DataStage 314Svr

A data warehouse is a central database that integrates data from many operational sources within an organization. The data is transformed, summarized, and organized to support business analysis and report generation. Repository of data Optimized for analysis Supports business: Projections Comparisons Assessments Extracted from operational sources Integrated Summarized Filtered Cleansed Denormalized Historical
1-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

Data marts are like data warehouses but smaller in scope. Frequently an organization will have both an enterprise-wide data warehouse and data marts that extract data from it for specialized purposes. Like data warehouses but smaller in scope Organize data from a single subject area or department Solve a small set of business requirements Are cheaper and faster to build than a data warehouse Distribute data away from the data warehouse

1-5

Module 1 Introduction to DataStage

DataStage 314Svr

DataStage is a comprehensive tool for the fast, easy creation and maintenance of data marts and data warehouses. It provides the tools you need to build, manage, and expand them. With DataStage, you can build solutions faster and give users access to the data and reports they need. With DataStage you can: Design the jobs that extract, integrate, aggregate, load, and transform the data for your data warehouse or data mart. Create and reuse metadata and job components. Run, monitor, and schedule these jobs. Administer your development and execution environments.

1-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

DataStage is client/server software. The server stores all DataStage objects and metadata in a repository, which consists of the UniVerse RDBMS. The clients interface with the server. The clients run on Windows 95 or later (Windows 98, NT, 2000). The server runs on Windows NT 4.0 and Windows 2000. Most versions of UNIX are supported. See the installation release notes for details. The DataStage client components are: Component Administrator Designer Director Manager Description Administers DataStage projects and conducts housekeeping on the server Creates DataStage jobs that are compiled into executable programs Used to run and monitor the DataStage jobs Allows you to view and edit the contents of the repository

1-7

Module 1 Introduction to DataStage

DataStage 314Svr

True or False? The DataStage Server and clients must be running on the same machine. True: Incorrect. Typically, there are many client machines each accessing the same DataStage Server running on a separate machine. The Server can be running on Windows NT or UNIX. The clients can be running on a variety of Windows platforms. False: Correct! Typically, there are many client machines each accessing the same DataStage Server running on a separate machine. The Server can be running on Windows NT or UNIX. The clients can be running on a variety of Windows platforms.

1-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

Use the Administrator to specify general server defaults, add and delete projects, and to set project properties. The Administrator also provides a command interface to the UniVerse repository. Use the Administrator Project Properties window to: Set job monitoring limits and other Director defaults on the General tab. Set user group privileges on the Permissions tab. Enable or disable server-side tracing on the Tracing tab. Specify a user name and password for scheduling jobs on the Schedule tab. Specify hashed file stage read and write cache sizes on the Tunables tab.

General server defaults can be set on the Administrator DataStage Administration window (not shown): Change license information. Set server connection timeout.

The DataStage Administrator is discussed in detail in a later module.

1-9

Module 1 Introduction to DataStage

DataStage 314Svr

Use the Manager to store and manage reusable metadata for the jobs you define in the Designer. This metadata includes table and file layouts and routines for transforming extracted data. Manager is also the primary interface to the DataStage repository. In addition to table and file layouts, it displays the routines, transforms, and jobs that are defined in the project. Custom routines and transforms can also be created in Manager.

1 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

The DataStage Designer allows you to use familiar graphical point-and-click techniques to develop processes for extracting, cleansing, transforming, integrating and loading data into warehouse tables. The Designer provides a visual data flow method to easily interconnect and configure reusable components. Use Designer to: Specify how the data is extracted. Specify data transformations. Decode (denormalize) data going into the data mart using reference lookups. For example, if the sales order records contain customer IDs, you can look up the name of the customer in the CustomerMaster table. This avoids the need for a join when users query the data mart, thereby speeding up the access. Aggregate data. Split data into multiple outputs on the basis of defined constraints.

You can easily move between the Director, Designer, and Manager by selecting commands in the Tools menu.

1 - 11

Module 1 Introduction to DataStage

DataStage 314Svr

Use the Director to validate, run, schedule, and monitor your DataStage jobs. You can also gather statistics as the job runs.

1 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

Define your projects properties: Administrator Open (attach to) your project Import metadata that defines the format of data stores your jobs will read from or write to: Manager Design the job: Designer Define data extractions (reads) Define data flows Define data integration Define data transformations Define data constraints Define data loads (writes) Define data aggregations

Compile and debug the job: Designer Run and monitor the job: Director

1 - 13

Module 1 Introduction to DataStage

DataStage 314Svr

All your work is done in a DataStage project. Before you can do anything, other than some general administration, you must open (attach to) a project. Projects are created during and after the installation process. You can add projects after installation on the Projects tab of Administrator. A project is associated with a directory. The project directory is used by DataStage to store your jobs and other DataStage objects and metadata. You must open (attach to) a project before you can do any work in it. Projects are self-contained. Although multiple projects can be open at the same time, they are separate environments. You can, however, import and export objects between them. Multiple users can be working in the same project at the same time. However, DataStage will prevent multiple users from accessing the same job at the same time.

1 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

DataStage Designer is used to build and compile your Extraction, Transformation, and Load (ETL) jobs. True: Correct! With Designer you can graphically build your job by placing graphical components (called "stages") on a canvas. After you build it, your job is compiled in Designer. False: Incorrect. With Designer you can graphically build your job by placing graphical components (called "stages") on a canvas. After you build it, your job is compiled in Designer. DataStage Manager is used to execute your jobs after you build them. True: Incorrect. DataStage Manager is your primary interface to the DataStage repository. Use Manager to manage metadata and other DataStage objects. False: Correct! DataStage Manager is your primary interface to the DataStage repository. Use Manager to manage metadata and other DataStage objects.

1 - 15

Module 1 Introduction to DataStage

DataStage 314Svr

DataStage Director is used to execute your jobs after they have been built. True: Correct! Use Director to validate and run your jobs. You can also monitor the job while it is running. False: Incorrect. Use Director to validate and run your jobs. You can also monitor the job while it is running. DataStage Administrator is used to set global and project properties. True: Correct! You can set some global properties such as connection timeout, as well as project properties, such as permissions. False: Incorrect. You can set some global properties such as connection timeout, as well as project properties, such as permissions.

1 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 1 Introduction to DataStage

1 - 17

Module 2

Installing DataStage

Module 2 Installing DataStage

DataStage 314Svr

2-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Installing DataStage

The DataStage server should be installed before the DataStage clients are installed. The server can be installed on Windows NT (including Workstation and Server), Windows 2000, or UNIX. This module describes the Windows NT installation. The exact system requirements depend on your version of DataStage. See the installation CD for the latest system requirements. To install the server you will need the installation CD and a license for the DataStage server. The license contains the following information: Serial number Project count The maximum number of projects you can have installed on the server. This includes new projects as well as previously created projects to be upgraded. Expiration date Authorization code This information must be entered exactly as written in the license.

2-3

Module 2 Installing DataStage

DataStage 314Svr

The installation wizard guides you through the following steps: Enter license information Specify server directories Select program folder Create new projects and/or upgrade existing projects

2-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Installing DataStage

2-5

Module 2 Installing DataStage

DataStage 314Svr

2-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Installing DataStage

The DataStage services must be running on the server machine in order to run any DataStage client applications. To start or stop the DataStage services in Windows 2000, open the DataStage Control Panel window in the Windows 2000 Control Panel. Then click Start All Services (or Stop All Services). These services must be stopped when installing or reinstalling DataStage. UNIX note: In UNIX, these services are started and stopped using the uv.rc script with the stop or start command options. The exact name varies by platform. For SUN Solaris, it is /etc/rc2.d/S99uv.rc.

2-7

Module 2 Installing DataStage

DataStage 314Svr

The DataStage clients should be installed after the DataStage server is installed. The clients can be installed on Windows 95, Windows 98, Windows NT, or Windows 2000. There are two editions of DataStage. The Developers edition contains all the client applications (in addition to the server). The Operators edition contains just the client applications needed to run and monitor DataStage jobs (in addition to the server), namely, the Director and Administrator.

To install the Developers edition you need a license for DataStage Developer. To install the Operators edition you need a license for DataStage Director. The license contains the following information: Serial number User limit Expiration date Authorization code This information must be entered exactly as written in the license.

2-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Installing DataStage

2-9

Module 2 Installing DataStage

DataStage 314Svr

2 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

Module 3

Configuring Projects

Module 3 Configuring Projects

DataStage 314Svr

3-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 3 Configuring Projects

In DataStage all development work is done within a project. Projects are created during installation and after installation using Administrator. Each project is associated with a directory. The directory stores the objects (jobs, metadata, custom routines, etc.) created in the project. Before you can work in a project you must attach to it (open it). You can set the default properties of a project using DataStage Administrator.

3-3

Module 3 Configuring Projects

DataStage 314Svr

3-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 3 Configuring Projects

Click Properties on the DataStage Administration window to open the Project Properties window. There are five active tabs. (The Mainframe tab is only enabled if your license supports mainframe jobs.) The default is the General tab. If you select the Enable job administration in Director box, you can perform some administrative functions in Director without opening Administrator. When a job is run in Director, events are logged describing the progress of the job. For example, events are logged when a job starts, when it stops, and when it aborts. The number of logged events can grow very large. The Auto-purge of job log box tab allows you to specify conditions for purging these events. You can limit the logged events either by number of days or number of job runs.

3-5

Module 3 Configuring Projects

DataStage 314Svr

Use this page to set user group permissions for accessing and using DataStage. All DataStage users must belong to a recognized user role before they can log on to DataStage. This helps to prevent unauthorized access to DataStage projects. There are three roles of DataStage user: DataStage Developer, who has full access to all areas of a DataStage project. DataStage Operator, who can run and manage released DataStage jobs. <None>, who does not have permission to log on to DataStage.

UNIX note: In UNIX, the groups displayed are defined in /etc/group.

3-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 3 Configuring Projects

This tab is used to enable and disable server-side tracing. The default is for server-side tracing to be disabled. When you enable it, information about server activity is recorded for any clients that subsequently attach to the project. This information is written to trace files. Users with in-depth knowledge of the system software can use it to help identify the cause of a client problem. If tracing is enabled, users receive a warning message whenever they invoke a DataStage client. Warning: Tracing causes a lot of server system overhead. This should only be used to diagnose serious problems.

3-7

Module 3 Configuring Projects

DataStage 314Svr

Use the Schedule tab to specify a user name and password for running scheduled jobs in the selected project. If no user is specified here, the job runs under the same user name as the system scheduler.

3-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 3 Configuring Projects

On the Tunables tab, you can specify the sizes of the memory caches used when reading rows in hashed files and when writing rows to hashed files. Hashed files are mainly used for lookups and are discussed in a later module. Active-to-Active link performance settings will be covered in detail in a later module in this course.

3-9

Module 3 Configuring Projects

DataStage 314Svr

3 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

Module 4

Designing and Running Jobs

Module 4 Designing and Running Jobs

DataStage 314Svr

4-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

A job is an executable DataStage program. In DataStage, you can design and run jobs that perform many useful data warehouse tasks, including data extraction, data conversion, data aggregation, data loading, etc. DataStage jobs are: Designed and built in Designer. Scheduled, invoked, and monitored in Director. Executed under the control of DataStage.

4-3

Module 4 Designing and Running Jobs

DataStage 314Svr

In this module, you will go through the whole process with a simple job, except for the first bullet. In this module you will manually define the metadata.

4-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

In the center right is the Designer canvas. On it you place stages and links from the Tools Palette on the right. On the bottom left is the Repository window, which displays the branches in Manager. Items in Manager, such as jobs and table definitions can be dragged to the canvas area. Click View>Repository to display the Repository window. Click View>Property Browser to display the Property Broswer window. This window displays the properties of objects selected on the canvas.

4-5

Module 4 Designing and Running Jobs

DataStage 314Svr

The toolbar at the top contains quick access to the main functions of Designer.

4-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

The tool palette contains icons that represent the components you can add to your job design. Most of the stages shown here are automatically installed when you install DataStage. You can also install additional stages called plug-ins for special purposes. For example, there is a plug-in called sort that can be used to sort data. Plug-ins are discussed in a later module.

4-7

Module 4 Designing and Running Jobs

DataStage 314Svr

There are two kinds of stages: Passive stages define read and write access to data sources and repositories. Sequential ODBC Hashed Transformer Aggregator Sort plug-in

Active stages define how data is filtered and transformed.

4-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

True or False? The Sequential stage is an active stage. True: Incorrect. The Sequential stage is considered a passive stage because it is used to extract or load sequential data from a file. It is not used to transform or modify data. False: Correct! The Sequential stage is considered a passive stage because it is used to extract or load sequential data from a file. It is not used to transform or modify data.

4-9

Module 4 Designing and Running Jobs

DataStage 314Svr

4 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

The Sequential stage is used to extract data from a sequential file or to load data into a sequential file. The main things you need to specify when editing the sequential file stage are the following: Path and name of file File format Column definitions If the sequential stage is being used as a target, specify the write action: Overwrite the existing file or append to it.

4 - 11

Module 4 Designing and Running Jobs

DataStage 314Svr

4 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

Defining a sequential target stage is similar to defining a sequential source stage. You are defining the format of the data flowing into the stage, that is, from the input links. Define each input link listed in the Input name box. You are defining the file the job will write to. If the file doesnt exist, it will be created. Specify whether to overwrite or append the data in the Update action set of buttons. General Tab Filter command. Here you can specify a filter program for processing the file you are extracting data from. This feature can be used, for example, to unzip a compressed file before reading it. You can type in or browse for the filter program, and specify any command line arguments it requires in the text box. This text box is enabled only if you have selected the Stage uses filter commands checkbox on the Stage page General tab. Note that, if you specify a filter command, data browsing is not available so the View Data button is disabled. On the Format tab, you can specify a different format for the target file than you specified for the source file. If the target file doesnt exist, you will not (of course!) be able to view its data until after the job runs. If you click the View data button, DataStage will return a Failed to open error.

4 - 13

Module 4 Designing and Running Jobs

DataStage 314Svr

The column definitions you defined in the source stage for a given (output) link will appear already defined in the target stage for the corresponding (input) link. Think of a link as like a pipe. What flows in one end flows out the other end. The format going in is the same as the format going out.

4 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

The Transformer stage is the primary active stage. Other active stages perform more specialized types of transformations. In the Transformer stage you can specify: Column mappings Derivations Constraints

A column mapping maps an input column to an output column. Values are passed directly from the input column to the output column. Derivations calculate the values to go into output columns based on values in zero or more input columns. Constraints specify the conditions under which incoming rows will be written to output links.

4 - 15

Module 4 Designing and Running Jobs

DataStage 314Svr

Notice the following elements of the transformer: The top, left pane displays the columns of the input links. If there are multiple input links, multiple sets of columns are displayed. The top, right pane displays the contents of the output links. We havent defined any fields here yet. If there are multiple output links, multiple sets of columns are displayed. For now, ignore the Stage Variables window in the top, right pane. This will be discussed in a later module. The bottom area shows the column definitions (metadata) for the input and output links. If there are multiple input and/or output links, there will be multiple tabs.

4 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

4 - 17

Module 4 Designing and Running Jobs

DataStage 314Svr

Add one or more Annotation stages to the canvas to document your job. An Annotation stage works like a text box with various formatting options. You can optionally show or hide the Annotation stages by pressing a button on the toolbar. There are two Annotation stages. The Description Annotation stage is discussed in a later module.

4 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

Type the text in the box. Then specify the various options including: Text font and color Text box color Vertical and horizontal text justification

4 - 19

Module 4 Designing and Running Jobs

DataStage 314Svr

Before you can run your job, you must compile it. This generates executable code that can be run by the DataStage Server engine. To compile a job, click File>Compile or click the Compile button on the toolbar. The Compile Job window displays the status of the compile. If an error occurs: Click Show Error to identify the stage where the error occurred. Click More to retrieve more information about the error.

4 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

As you know, you run your jobs in Director. You can open Director from within Designer by clicking Tools>Run Director. In a similar way, you can move between Director, Manager, and Designer. There are two methods for running a job: Run it immediately. Schedule it to run at a later time or date. Select the job in the Job Status view. The job must have been compiled. Click Job>Run Now or click the Run Now button in the toolbar. The Job Run Options window is displayed.

To run a job immediately:

4 - 21

Module 4 Designing and Running Jobs

DataStage 314Svr

This shows the Director Job Status view. To run a job, select it and then click Job>Run Now. Other views available: Job log view messages from job run Schedule view dates and times job is scheduled to run

4 - 22 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

The Job Run Options window is displayed when you click Job>Run Now. This window allows you to stop the job after: A certain number of rows. A certain number of warning messages.

You can validate your job before you run it. Validation performs some checks that are necessary in order for your job to run successfully. These include: Verifying that connections to data sources can be made. Verifying that files can be opened. Verifying that SQL statements used to select data can be prepared.

Click Run to run the job after it is validated. The Status column displays the status of the job run.

4 - 23

Module 4 Designing and Running Jobs

DataStage 314Svr

Click the Log button in the toolbar to view the job log. The job log records events that occur during the execution of a job. These events include control events, such as the starting, finishing, and aborting of a job; informational messages; warning messages; error messages; and program-generated messages.

4 - 24 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

4 - 25

Module 4 Designing and Running Jobs

DataStage 314Svr

4 - 26 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 4 Designing and Running Jobs

4 - 27

Module 5

Working with Meta Data

Module 5 Working with Meta Data

DataStage 314Svr

5-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

DataStage Manager is a graphical tool for managing the contents of your DataStage project repository, which contains metadata and other DataStage components such as jobs and routines. Metadata is data about data that describes the formats of sources and targets. This includes general format information such as whether the record columns are delimited and, if so, the delimiting character. It also includes the specific column definitions.

5-3

Module 5 Working with Meta Data

DataStage 314Svr

5-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

The left pane contains the project tree. There are eight main branches, but you can create subfolders under each. Select a folder in the project tree to display its contents. In this example, a folder named DS304 has been created that contains some of the jobs in the project. Data Elements branch: Lists the built-in and custom data elements. (Data elements are extensions of data types, and are discussed in a later module.) Jobs branch: Lists the jobs in the current project. Routines branch: Lists the built-in and custom routines. Routines are blocks of DataStage BASIC code that can be called within a job. (Routines are discussed in a later module.) Shared Containers branch: Shared Containers encapsulate sets of DataStage components into a single stage. (Shared Containers are discussed in a later module.) Stage Types branch: Lists the types of stages that are available within a job. Built-in stages include the sequential and transformer stages you used in Designer. Table Definitions branch: Lists the table definitions available for loading into a job.

5-5

Module 5 Working with Meta Data

DataStage 314Svr

Transforms branch: Lists the built-in and custom transforms. Transforms are functions you can use within a job for data conversion. Transforms are discussed in a later module.

5-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

DataStage Manager manages two different types of objects: Metadata describing sources and targets: Called table definitions in Manager. These are not to be confused with relational tables. DataStage table definitions are used to describe the format and column definitions of any type of source: sequential, relational, hashed file, etc. Table definitions can be created in Manager or Designer and they can also be imported from the sources or targets they describe. DataStage components Every object in DataStage (jobs, routines, table definitions, etc.) is stored in the DataStage repository. Manager is the interface to this repository. DataStage components, including whole projects, can be exported from and imported into Manager.

5-7

Module 5 Working with Meta Data

DataStage 314Svr

Any set of DataStage objects, including whole projects, which are stored in the Manager Repository, can be exported to a file. This export file can then be imported back into DataStage. Import and export can be used for many purposes, including: Backing up jobs and projects. Maintaining different versions of a job or project. Moving DataStage objects from one project to another. Just export the objects, move to the other project, then re-import them into the new project. Sharing jobs and projects between developers. The export files, when zipped, are small and can be easily emailed from one developer to another.

5-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

Click Export>DataStage Components in Manager to begin the export process. Any object in Manager can be exported to a file. Use this procedure to backup your work or to move DataStage objects from one project to another. Select the types of components to export. You can select either the whole project or select a portion of the objects in the project. Specify the name and path of the file to export to. By default, objects are exported to a text file in a special format. By default, the extension is dsx. Alternatively, you can export the objects to an XML document. The directory you export to is on the DataStage client, not the server.

5-9

Module 5 Working with Meta Data

DataStage 314Svr

True or False? You can export DataStage objects such as jobs, but you can't export metadata, such as field definitions of a sequential file. True: Incorrect. Metadata describing files and relational tables are stored as "Table Definitions". Table definitions can be exported and imported as any DataStage objects can. False: Correct! Metadata describing files and relational tables are stored as "Table Definitions". Table definitions can be exported and imported as any DataStage objects can.

5 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

True or False? The directory you export to is on the DataStage client machine, not on the DataStage server machine. True: Correct! The directory you select for export must be addressible by your client machine. False: Incorrect. The directory you select for export must be addressible by your client machine.

5 - 11

Module 5 Working with Meta Data

DataStage 314Svr

5 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

To import DataStage components, click Import>DataStage Components. Select the file to import. Click Import all to begin the import process or Import selected to view a list of the objects in the import file. You can import selected objects from the list. Select the Overwrite without query button to overwrite objects with the same name without warning.

5 - 13

Module 5 Working with Meta Data

DataStage 314Svr

5 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

5 - 15

Module 5 Working with Meta Data

DataStage 314Svr

Table definitions define the formats of a variety of data files and tables. These definitions can then be used and reused in your jobs to specify the formats of data stores. For example, you can import the format and column definitions of the Customers.txt file. You can then load this into the sequential source stage of a job that extracts data from the Customers.txt file. You can load this same metadata into other stages that access data with the same format. In this sense the metadata is reusable. It can be used with any file or data store with the same format. If the column definitions are similar to what you need you can modify the definitions and save the table definition under a new name. You can also use the same table definition for different types of data stores with the same format. For example, you can import a table definition from a sequential file and use it to specify the format for an ODBC table. In this sense the metadata is loosely coupled with the data whose format it defines. You can import and define several different kinds of table definitions including: Sequential files, ODBC data sources, UniVerse tables, hashed files.

5 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

To start the import, click Import>Table Definitions>Sequential File Definitions. The Import Meta Data (Sequential) window is displayed. Select the directory containing the sequential files. The Files box is then populated with the files you can import. Select the file to import. Select or specify a category (folder) to import into. The format is: <Category>\<Sub-category> <Category> is the first-level sub-folder under Table Definitions. <Sub-category> is (or becomes) a sub-folder under the type.

5 - 17

Module 5 Working with Meta Data

DataStage 314Svr

In Manager, select the category (folder) that contains the table definition. Double-click the table definition to open the Table Definition window. Click the Columns tab to view and modify any column definitions. Select the Format tab to edit the file format specification.

5 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

5 - 19

Module 5 Working with Meta Data

DataStage 314Svr

5 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 5 Working with Meta Data

5 - 21

Module 5 Working with Meta Data

DataStage 314Svr

5 - 22 Copyright 2002 Ascential Software Corporation 09/01/02

Module 6

Working with Relational Data

Module 6 Working with Relational Data

DataStage 314Svr

6-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

You can perform the same tasks with relational data that you can with sequential data. You can extract, filter, and transform data from relational tables. You can also load data into relational tables. Although you can work with many relational databases through native drivers (including UniVerse, UniData, and Oracle), you can access many more relational databases using ODBC. In the ODBC stage, you can either specify your query to one or more tables in the database interactively or you can type the query or you can paste in an existing query.

6-3

Module 6 Working with Relational Data

DataStage 314Svr

Before you can access data through ODBC you must define an ODBC data source. In Windows NT, this can be done using the (32 bit) ODBC Data Source Administrator in the Control Panel. The ODBC Data Source Administrator has several tabs. For use with DataStage, you should define your data sources on the System DSN tab (not User DSN). You can install drivers for most of the common relational database systems from the DataStage installation CD. Click Add to define a new data source. When you click Add a list of available drivers is displayed. Select the appropriate driver and then click Finish. Different relational databases have different requirements. As an example, we will define a Microsoft Access data source. Type the name of the data source in the Data Source Name box. Click Select to define a connection to an existing database. Type the name and location of the database. Click Create to define a connection to a new database.

6-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

6-5

Module 6 Working with Relational Data

DataStage 314Svr

Importing table definitions from ODBC databases is similar to importing sequential file definitions. Click Import>Table Definitions>ODBC Table Definitions in Manager to start the process. The DSN list displays the data sources that are defined for the DataStage Server. Select the data source you want to import from and, if necessary, provide a user name and password. The Import Metadata window is displayed. It lists all tables in the database that are available for import. Select one or more tables and a category to import to, and then click OK.

6-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

Extracting data from a relational table is similar to extracting data from a sequential file except that you use an ODBC stage instead of a sequential stage. In this example, well extract data from a relational table and load it into a sequential file.

6-7

Module 6 Working with Relational Data

DataStage 314Svr

Specify the ODBC data source name in the Data source name box on the General tab of the ODBC stage. You can click the Get SQLInfo button to retrieve the quote character and schema delimiters from the ODBC database.

6-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

Specify the table name on the General tab of the Outputs tab. Select Generated query to define the SQL SELECT statement interactively using the Columns and Selection tabs. Select User-defined SQL query to write your own SQL SELECT statement to send to database.

6-9

Module 6 Working with Relational Data

DataStage 314Svr

Load the table definitions from Manager on the Columns tab. The procedure is the same as for sequential files. When you click Load, the Select Columns window is displayed. Select the columns data is to be extracted from.

6 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

Optionally, specify a WHERE clause and other additional SQL clauses on the Selection tab. Other clauses can be anything else you wish to add to the Select clause, such as ORDER BY.

6 - 11

Module 6 Working with Relational Data

DataStage 314Svr

The View SQL tab enables you to view the SELECT statement that will be used to select the data from the table. The SQL displayed in read-only. Click View Data to test the SQL statement against the database.

6 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

If you want to define your own SQL query, click User-defined SQL query on the General tab and then write or paste the query into the SQL for primary inputs box on the SQL Query tab.

6 - 13

Module 6 Working with Relational Data

DataStage 314Svr

6 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

Editing an ODBC target stage is similar to editing an ODBC source stage. It includes the following tasks: Specify the data source containing the target table. Specify the name of the table. Select the update action. You can choose from a variety of INSERT and/or UPDATE actions. Optionally, create the table. Load the column definitions from the Manager table definition.

6 - 15

Module 6 Working with Relational Data

DataStage 314Svr

Some of the options are different in the ODBC stage when it is used as a target. Select the type of action to perform from the Update action list. You can optionally have DataStage create the target table or you can load to an existing table. On the View SQL tab you can view the SQL statement used to insert the data into the target table.

6 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

On the Edit DDL tab you can generate and modify the CREATE TABLE statement used to create the target table. If you make any changes to column definitions, you need to regenerate the CREATE TABLE statement by clicking the Create DDL button.

6 - 17

Module 6 Working with Relational Data

DataStage 314Svr

Transaction Handling: Allows you to specify a transaction isolation level for read data. The isolation level specifies how potential conflicts between transactions (i.e., dirty read, nonrepeatable reads, and phantom reads) are handled. By default, all the rows are written to the target table before a COMMIT. In the Rows per transaction box, you can specify a specific number of rows to write before the COMMIT.

6 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

6 - 19

Module 6 Working with Relational Data

DataStage 314Svr

True or False? Using a single ODBC stage, you can only extract data from a single table. True: Incorrect. You can join data from multiple tables within a single data source. False: Correct! You can join data from multiple tables within a single data source.

6 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

6 - 21

Module 6 Working with Relational Data

DataStage 314Svr

6 - 22 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

The ORAOCI8 plug-in lets you rapidly and efficiently prepare and load streams of tabular data from any DataStage stage (for example, the ODBC stage, the Sequential File stage, and so forth) to and from tables of the target Oracle database. The Oracle client on Windows NT or UNIX uses SQL*Net to access an Oracle server on Windows NT or UNIX.

6 - 23

Module 6 Working with Relational Data

DataStage 314Svr

The plug-in appears as any other stage on the designer work area. It can extract or write data contained in Oracle tables. Features: Each ORAOCI8 plug-in stage is a passive stage that can have any number of input, output, and reference output links. Input links specify the data you are writing, which is a stream of rows to be loaded into an Oracle database. You can specify the data on an input link using an SQL statement constructed by DataStage or a user-defined SQL statement. Output links specify the data you are extracting, which is a stream of rowsto be read from an Oracle database. You can also specify the data on an output link using an SQL statement constructed by DataStage or a userdefined SQL statement. Each reference output link represents a row that is key read from an Oracle database (that is, it reads the record using the key field in the WHERE clause of the SQL SELECT statement).

6 - 24 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

General Tab
This tab is displayed by default. It contains the following fields: Table name. This required field is editable when the update action is not Userdefined SQL (otherwise, it is read-only). It is the name of the target Oracle table the data is written to, and the table must exist or be created by choosing generate DDL from the Create table action list. You must have insert, update, or delete privileges, depending on input mode. You must specify Table name if you do not specify User-defined SQL. There is no default. Click (Browse button) to browse the Repository to select the table. Update action. Specifies which SQL statements are used to update the target table. Some update actions require key columns to update or delete rows. There is no default. Choose the option you want from the list. Clear table then insert rows. Deletes the contents of the table and adds the new rows, with slower performance because of transaction logging. Truncate table then insert rows. Truncates the table with no transaction logging and faster performance.

6 - 25

Module 6 Working with Relational Data

DataStage 314Svr

Insert rows without clearing. Inserts the new rows in the table. Delete existing rows only. Deletes existing rows in the target table that have identical keys in the source files. Replace existing rows completely. Deletes the existing rows, then adds the new rows to the table. Update existing rows only. Updates the existing data rows. Any rows in the data that do not exist in the table are ignored. Update existing rows or insert new rows. Updates the existing data rows before adding new rows. It is faster to update first when you have a large number of records. Insert new rows or update existing rows. Inserts the new rows before updating existing rows. It is faster to insert first if you have only a few records. User-defined SQL. Writes the data using a user-defined SQL statement, which overrides the default SQL statement generated by the stage. If you choose this option, you enter the SQL statement on the SQL tab. User-defined SQL file. Reads the contents of the specified file to write the data. Transaction Isolation. Provides the necessary concurrency control between transactions in the job and other transactions. Use one of the following transaction isolation levels: Read committed. Takes exclusive locks on modified data and sharable locks on all other data. Each query executed by a transaction sees only data that was committed before the query (not the transaction) began. Oracle queries never read dirty (uncommitted) data. This is the default. Serializable. Takes exclusive locks on modified data and sharable locks on all other data. Serializable transactions see only the changes that were committed at the time the transaction began. Note: If Enable transaction grouping is selected on the Transaction Handling tab, only the Transaction Isolation value for the first link is used for the entire group. Array size. Specifies the number of rows to be transferred in one call between DataStage and Oracle before they are written. Enter a positive integer to indicate how often Oracle performs writes at a time to the database. The default value is 1, that is, each row is written in a separate statement. Larger numbers use more memory on the client to cache the
6 - 26 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 6 Working with Relational Data

rows. This minimizes server round trips and maximizes performance by executingfewer statements. If this number is too large, the client may run out of memory. Transaction size. This field exists for backward compatibility, but it is ignored for version 3.0 and later of the plug-in. The transaction size for new jobs is now handled by Rows per transaction on the Transaction Handling tab. Create table action. Creates the target table in the specified database if Generate DDL is selected. It uses the column definitions in the Columns tab and the table name and the TABLESPACE and STORAGE properties for the target table. The generated Create Table statement includes the TABLESPACE and STORAGE keywords, which indicate the location where the table is created and the storage expression for the Oracle storage_clause. You must have CREATE TABLE privileges on your schema. You can also specify your own CREATE TABLE SQL statement. You must enter the storage clause in Oracle format. (Use the User-defined DDL tab on the SQL tab for a complex statement.)

6 - 27

Module 7

Constraints and Derivations

Module 7 Constraints and Derivations

DataStage 314Svr

7-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

A constraint specifies the condition under which data flows through a link. For example, suppose you want to split the data in the jobs file into separate files based on the job level. We need to define a constraint on each link so that only jobs within a certain level range are written to each file.

7-3

Module 7 Constraints and Derivations

DataStage 314Svr

Click the Constraints button in the toolbar at the top of the Transformer Stage window to open the Transformer Stage Contraints window. The Transformer Stage Contraints window lists all the links out of the transformer. Double-click on the cell next to a link to create the constraint. Rows that are not written out to previous rows are written to a rejects link. A row of data is sent down all the links it satisfies. If there is no constraint on a (non-rejects) link, all rows will be sent down the link.

7-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

This shows the Constraints window. Constraints are defined for each of the top three links. The Reject Row box is selected for the last link. All rows that fail to satisfy the top three links will be sent down this link.

7-5

Module 7 Constraints and Derivations

DataStage 314Svr

True or False? A constraint specifies a condition under which incoming rows of data will be written to an output link True: Correct! You can separately define a constraint for each output link. If no constraint is written for a particular output link, then all rows will be written to that link. False: Incorrect. You can separately define a constraint for each output link. If no constraint is written for a particular output link, then all rows will be written to that link.

7-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

True or False? A Rejects link can be placed anywhere in the link ordering. True: Incorrect. A Rejects link should be placed last in the link ordering, if it is to get every row that doesn't satisfy any of the other constraints. False: Correct! A Rejects link should be placed last in the link ordering, if it is to get every row that doesn't satisfy any of the other constraints.

7-7

Module 7 Constraints and Derivations

DataStage 314Svr

7-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

A derivation is an expression that specifies the value to be moved into a target column (field). Every target column must have a derivation. The simplest derivation is an input column. The value in the input column is moved to the target column. To construct a derivation for a target column double-click on the derivation cell next to the target column. Derivations are constructed in the same way that constraints are constructed: Type constants. Type or enter operators from Operator shortcut menu. Type or enter operands from Operand shortcut menu. Constraints apply to links; derivations apply to columns. Constraints are conditions, either true or false; derivations specify a value to go into a target column.

Whats the difference between derivations and constraints?

7-9

Module 7 Constraints and Derivations

DataStage 314Svr

In this example the concatenation of several fields is moved into the FullName target field. The colon (:) is the concatenation operator. You can insert this from the Operator menu or type it in.

7 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

True or False? If the constraint for a particular link is not satisified, then the derivations defined for that link are not executed. True: Correct! Constraints have precedence over derivations. Derivations in an output link are only executed if the constraint is satisfied. False: Incorrect. Constraints have precedence over derivations. Derivations in an output link are only executed if the constraint is satisfied.

7 - 11

Module 7 Constraints and Derivations

DataStage 314Svr

7 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

You can create stage variables for use in your column derivations and constraints. Stage variables store values without writing them out to a target file or table. They can be used in expressions just like constants, input columns, and other operands. Stage variables retain their values across reads. This allows them to be used as counters and accumulators. You can also use them to compare a current input value to a previous input value. To create a new stage variable, click the right mouse button over the Stage Variables window and then click Append New Stage Variable (or Insert New Stage Variable). After you create it, you specify a derivation for it in the same way as for columns.

7 - 13

Module 7 Constraints and Derivations

DataStage 314Svr

This lists the execution order: Derivations in stage variables are executed before constraints. This allows them to be used in constraints. Next constraints are executed. Then column derivations are executed. Derivations in higher columns are executed before lower columns.

7 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

Note the output link reordering icon available on the toolbar from within the Transformer stage.

7 - 15

Module 7 Constraints and Derivations

DataStage 314Svr

To get to the link ordering screen, open the transformer stage, then click on the output link execution order icon. The above screen will appear. Select a link and use the arrow buttons to reposition a link in the execution order.

7 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

Derivations for stage variables are executed before derivations for any output link columns. True: Correct! So you can be sure that the derivations for any of the stage variables referenced in column derivations will have already been executed. False: Incorrect. The derivations for stage variables are executed first. So you can be sure that the derivations for any of the stage variables referenced in column derivations will have already been executed.

7 - 17

Module 7 Constraints and Derivations

DataStage 314Svr

7 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 7 Constraints and Derivations

7 - 19

Module 7 Constraints and Derivations

DataStage 314Svr

7 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

Module 8

Creating Basic Expressions

Module 8 Creating Basic Expressions

DataStage 304

8-2 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

DataStage BASIC is a form of BASIC that has been customized to work with DataStage. In the previous module you learned how to define constraints and derivations. Derivations and constraints are written using DataStage BASIC. Job control routines, which are discussed in a later module, are also written in DataStage BASIC. This module will not attempt to teach you BASIC programming. Our focus is on what you need to know in order to construct complex DataStage constraints and derivations.

8-3

Module 8 Creating Basic Expressions

DataStage 304

For more information about BASIC operators than is provided here, search for BASIC Operators in Help. You can insert these operators from the Operators menu (except for the IF operator, which is on the Operands menu). Arithmetic operators: -, +, *, / Relational operators: =, <, >, <=, >= Logical operators: AND, OR, NOT IF operator: IF min_lvl < 0 THEN Out of Range ELSE In Range Concatenation operator (:) The employees name is : lname : , : fname Substring operator ([start, length]). First character is 1 (not 0). APPL3245[1, 4] APPL APPL3245[5, 2] 32

8-4 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

For more information about BASIC functions than is provided here, look up Alphabetical List BASIC Functions and Statements in Help. BASIC functions include the standard Pick BASIC functions. Click Function from the Operands menu to insert a function. Here are a few of the more common functions: TRIM(string), TRIM(string, character), TRIMF, TRIMB TRIM( xyz LEN(string) UPCASE(string), DOWNCASE(string) ICONV, OCONV ICONV is used to convert values to an internal format OCONV is used to convert values from an internal format Very powerful functions. Often used for date and time conversions and manipulations. These functions are discussed later in the module. ) xyz

8-5

Module 8 Creating Basic Expressions

DataStage 304

For more information about BASIC system variables than is provided here, look up System Variables in Help. Click System Variable from the Operands menu to insert a system variable. @DATE, @TIME @INROWNUM @OUTROWNUM @LOGNAME @NULL @TRUE, @FALSE @WHO Name of current project Date/time job started Extracted from @DATE row counter - incoming link row counter - outgoing link User logon name NULL value @YEAR, @MONTH, @DAY

8-6 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

True or False? TRIM is a system variable. True: Incorrect. TRIM is a DataStage function that removes surrounding spaces in a character string. False: Correct! TRIM is a DataStage function that removes surrounding spaces in a character string.

8-7

Module 8 Creating Basic Expressions

DataStage 304

True or False? @INROWNUM is a DataStage function. True: Incorrect. System variables all begin with the @-sign. @INROWNUM is a system variable that contains the number of the last row read from the input link. False: Correct! System variables all begin with the @-sign. @INROWNUM is a system variable that contains the number of the last row read from the input link.

8-8 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

DataStage is supplied with a number of functions you can use to obtain information about your jobs and projects. You can insert these functions into derivations. DS functions and macros are discussed in a later module.

8-9

Module 8 Creating Basic Expressions

DataStage 304

DS (DataStage) routines are defined in DataStage Manager. There are several types of DS routines. The type you can insert into your derivations and constraints are of the Transform Function type. A DS Transform Function Routine consists of a predefined block of BASIC statements that takes one or more arguments and returns a single value. DS routines are defined in DataStage Manager. You can define your own routines, but there are also a number of pre-built routines that are supplied with DataStage. The pre-built routines include a number of routines for manipulating dates, such as ConvertMonth, QuarterTag, and Timestamp.

8 - 10 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

8 - 11

Module 8 Creating Basic Expressions

DataStage 304

Data elements are extended data types. For example, a phone number is a kind of string. You could define a data element called PHONE.NUMBER to precisely define this type. Data elements are defined in DataStage Manager. A number of built-in types are supplied with DataStage. For example MONTH.TAG represents a string of the form YYYY-MM.

8 - 12 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

8 - 13

Module 8 Creating Basic Expressions

DataStage 304

DS Transforms are similar to DS Transform Function routines. They take one or more arguments and return a single value. There are two primary differences: The argument(s) and return value have specific data elements associated with them. In this sense, they transform data from one data element type to another data element type. Unlike DS routines, they do not consist of blocks of BASIC statements. Rather, they consist of a single (though possibly very complex) BASIC expression.

You can define your own DS Transforms, but there are also a number of pre-built transforms that are supplied with DataStage. The pre-built transforms include a number of routines for manipulating strings and dates.

8 - 14 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

8 - 15

Module 8 Creating Basic Expressions

DataStage 304

8 - 16 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

8 - 17

Module 8 Creating Basic Expressions

DataStage 304

Date manipulation in DataStage can be done in several ways: Using the Iconv and Oconv functions using the D conversion code. Using the built-in date Transforms. Using the built-in date routines. Using routines in the DataStage Software Development Kit (SDK)

Using routines in the DataStage Software Development Kit (SDK) is covered in another DataStage course. Your instructor can provide further details. The SDK routines are installed in the Manager Routines\sdk folder.

8 - 18 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

For detailed help on Iconv and Oconv, see their entries in the Alphabetical List of BASIC Functions and Statements in Help. Use Iconv to convert a string date in a variety of formats to the internal DataStage integer format. Use Oconv to convert an internal date to a string date in a variety of formats. Use these two functions together to covert a string date from one format to another. The internal format for a date is based on a reference date of December 31, 1967, which is day 0. Dates before are negative integers; dates after are positive integers. Use the D conversion code to specify the format of the date to be converted to an internal date by Iconv or the format of the date to be output by Oconv.

8 - 19

Module 8 Creating Basic Expressions

DataStage 304

For detailed help (more than you probably want), see D Code under Iconv or Oconv in Help. D4-MDY[2,2,4] D 4 MDY [2,2,4] Date conversion code Number of digits in year Separator Ordering is month, day, year Number of digits for M,D,Y, respectively

Note: The number in brackets for Y (namely 4) overrides the number following D. Iconv ignores some of the characters. Any separator will do. Number of characters is ignored if there are separators.

8 - 20 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

Iconv(12-31-67, D2-MDY[2,2,2]) Iconv(12311967, D MDY[2,2,4]) Oconv(0, D2-MDY[2,2,4]) Oconv(0, D2/DMY[2,2,2]) Oconv(10, D/YDM[4,2,A10])

0 0 12-31-1967 31/12/67 1968/10/JANUARY

Iconv(31-12-1967, D-DMY[2,2,4]) 0

This example illustrates the use of an additional formatting option. The A10 options says to alphabetically express the name, length 10 characters. Oconv( Iconv(12-31-67, D2-MDY[2,2,2]), D/YDM[4,2,A10]) 1967/31/DECEMBER This example shows how to convert from one string representation to another.

8 - 21

Module 8 Creating Basic Expressions

DataStage 304

8 - 22 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

DataStage provides a number of built-in transforms you can use for date conversions. The following data elements are used with the built-in transforms: Data element DATE.TAG WEEK.TAG MONTH.TAG QUARTER.TAG YEAR.TAG String format YYYY-MM-DD YYYYWnn YYYY-MM YYYYQn YYYY Example 1999-02-24 1999W06 1999-02 1999Q4 1999

8 - 23

Module 8 Creating Basic Expressions

DataStage 304

True or False? You can use Oconv to convert a string date from one format to another. True: Incorrect. Oconv by itself can't do this. You would first use Iconv to convert the input string into a day integer. Then you can use Oconv to convert the day integer into the output string. False: Correct! Oconv by itself can't do this. You would first use Iconv to convert the input string into a day integer. Then you can use Oconv to convert the day integer into the output string.

8 - 24 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

The transforms can be grouped into the following categories: String to day number Formatted string internal date integer Day number to date string Internal date integer formatted string Date string to date string DATE.TAG string formatted string

8 - 25

Module 8 Creating Basic Expressions

DataStage 304

The following transforms convert strings of the specified format (MONTH.TAG, QUARTER.TAG, ) to an internal date representing the first or last day of the period. Function MONTH.FIRST MONTH.LAST QUARTER.FIRST QUARTER.LAST WEEK.FIRST WEEK.LAST YEAR.FIRST YEAR.LAST YEAR.TAG WEEK.TAG QUARTER.TAG Tag MONTH.TAG Description Returns a numeric internal date corresponding to the first/last day of a month Returns a numeric internal date corresponding to the first/last day of a quarter Returns a numeric internal date corresponding to the first day (Monday) / last day (Sunday) of a week Returns a numeric internal date corresponding to the first/last day of a year

8 - 26 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

Examples: MONTH.FIRST(1993-02) 9164 MONTH.LAST(1993-02) 9191

8 - 27

Module 8 Creating Basic Expressions

DataStage 304

The following functions convert internal dates to strings in various formats (DATE.TAG, MONTH.TAG, ). Function DATE.TAG MONTH.TAG QUARTER.TAG WEEK.TAG Argument type Internal date Internal date Internal date Internal date Description Converts internal date to string in DATE.TAG format Converts internal date to string in MONTH.TAG format Converts internal date to string in QUARTER.TAG format Converts internal date to string in WEEK.TAG format

Examples: MONTH.TAG(9177) 1993-02 DATE.TAG(9177) 1993-02-14

8 - 28 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

The following functions convert strings in DATE.TAG format to strings in various other formats (DAY.TAG, MONTH.TAG, ). Function TAG.TO.MONTH TAG.TO.QUARTER TAG.TO.WEEK TAG.TO.DAY Tag DATE.TAG DATE.TAG DATE.TAG DATE.TAG Description Convert DATE.TAG to MONTH.TAG Convert DATE.TAG to QUARTER.TAG Convert DATE.TAG to WEEK.TAG Convert DATE.TAG to DAY.TAG

Examples: TAG.TO.MONTH(1993-02-14) 1993-02 TAG.TO.QUARTER(1993-02-14) 1993Q1

8 - 29

Module 8 Creating Basic Expressions

DataStage 304

8 - 30 Copyright 2002 Ascential Software Corporation 03/01/02

DataStage Essentials

Module 8 Creating Basic Expressions

8 - 31

Module 8 Creating Basic Expressions

DataStage 304

8 - 32 Copyright 2002 Ascential Software Corporation 03/01/02

Module 9

Troubleshooting

Module 9 Troubleshooting

DataStage 314Svr

9-2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

Events are logged to the job log file when a job is validated, run, or reset. You can use the log file to troubleshoot jobs that fail during validation or a run. Various entries are written to the log, including when: The job starts The job finishes An active stage starts An active stage finishes Rows are rejected (yellow icons) Errors occur (red icons) DataStage informational reports are logged User-invoked messages are displayed

09 - 3

Module 9 Troubleshooting

DataStage 314Svr

The event window shows the events that are logged for a job during its run. The job log contains the following information: Column Name Occurred On date Type Description Time the event occurred Date the event occurred Info Informational. No action required. Warning An error occurred. Investigate the cause of the warning, as this may indicate a serious error. Fatal A fatal error occurred. Control The job starts and finishes. Reject Rejected rows are output. Reset A job or the log is reset. Event A message describing the event. The system displays the first line of the message. If a message has an ellipsis () at the end, it contains more than one line. You can view the full message in the Event Detail window.

9-4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

Clearing the log


To clear the log, click Job>Clear Log.

09 - 5

Module 9 Troubleshooting

DataStage 314Svr

Double-click on an event to open the Event Detail window. This window gives you more information. When an active stage finishes, DataStage logs an informational message that describes how many rows were read in to the stage and how many were written. This provides you with valuable information that can indicate possible errors.

9-6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

The Monitor can be used to display information about a job while it is running. To start the Monitor, click Tools>New Monitor. Once in Monitor, click the right mouse button and then select Show links to display information about each of the input and output links.

09 - 7

Module 9 Troubleshooting

DataStage 314Svr

When you are testing a job, you can save time by limiting the number of rows and warnings.

9-8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

Server side tracing is enabled in Administrator. It is designed to be used to help customer support analysts troubleshoot serious problems. When enabled, it logs a record to a trace file whenever DataStage clients interact with the server. Caution: Because of the overhead caused by server side tracing it should only be used when working with customer support.

09 - 9

Module 9 Troubleshooting

DataStage 314Svr

9 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

DataStage provides a debugger for testing and debugging your job designs. The debugger runs within Designer. With the DataStage debugger you can: Set breakpoints on job links, including conditional breakpoints. Step through your job link-by-link or row-by-row. Watch the values going into link columns.

09 - 11

Module 9 Troubleshooting

DataStage 314Svr

To begin debugging a program, click View>Debug Bar to display the debug toolbar. The toolbar provides access to all of the debugging functions.
Stop Next link Debug job parameters Toggle breakpoint View job log

Clear breakpoints Go Next row Edit breakpoints Debug window

Button Go Next Link Next Row

Description Start/continue debugging. The job continues until the next action occurs on the link. The job continues until the next row is processed or ntil another link ith a breakpoint is

9 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

or until another link with a breakpoint is encountered. Stop Job Job Parameters Edit Breakpoints Toggle Breakpoint Clear All Breakpoints View job log Debug Window Stops the job at the point it is at. Click Go to continue. Set limits on rows and warnings. Displays the Edit Breakpoints window, in which you can edit existing breakpoints. Set or clear a breakpoint on a selected link. Removes breakpoints from all links. Open Director and view the job log. Show/hide the Debug Window, which displays link column values.

09 - 13

Module 9 Troubleshooting

DataStage 314Svr

To set a breakpoint on a link, select the link and then click the Toggle Breakpoint button. A black circle appears on the link.

9 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

Click the Edit Breakpoints button to open the Edit Breakpoints window. Existing breakpoints are listed in the lower pane. To set a condition for a breakpoint, select the breakpoint and then specify the condition in the above pane. You can either specify the number of rows before breaking or specify an expression to break upon when its true.

09 - 15

Module 9 Troubleshooting

DataStage 314Svr

Click the Debug Window button to open the Debug Window. The top pane lists all the columns defined for all links. The Local Data column lists the data currently in the column. The Current Break box at the top of the window lists the link where execution stopped. To add a column to the lower pane (where it is isolated), select the column and then click Add Watch. If a breakpoint is set, execution stops at that link when a row is written to the link.

9 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 9 Troubleshooting

You can step through row-by-row or step-by-step. Next Row extracts a row of data and stops at the next link with a breakpoint that the row is written to. For example, if a breakpoint is set on the MexicoCustomersOut link, execution stops at the MexicoCustomersOut link when a Mexican customer is read. If a breakpoint is not set on the MexicoCustomersOut link, execution will not stop at the MexicoCustomersOut link when a Mexican customer is read. Execution will stop at the CustomersIn link (even if there is no breakpoint set on it) because all rows are read through that link. Next Link stops at the next link that data is written to.

09 - 17

Module 9 Troubleshooting

DataStage 314Svr

9 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

Module 10

Defining Lookups

Module 10 Defining Lookups

DataStage 314Svr

10 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

A hashed file is a file that distributes records in one or more evenly-sized groups based on a primary key. The primary key value is processed by a "hashing algorithm" to determine the location of the record. The number of groups in the file is referred to as its modulus. In this example, there are 5 groups (modulus 5). Hashed files are used for reference lookups in DataStage because of their fast performance. The hashing algorithm determines the group the record is in. The groups contain a small number of records, so the record can be quickly located within the group. If write caching is enabled, DataStage does not write hashed file records directly to disk. Instead it caches the records in memory, and writes the cached records to disk when the cache is full. This improved performance. You can specify the size of the cache on the Tunables tab in Administrator.

10 - 3

Module 10 Defining Lookups

DataStage 314Svr

To create and load a hashed file, create a job that has the hashed file stage as a target. For example, heres a simple job that will create and load the StoresHashed hashed file, which will contain a list of stores and their addresses keyed by stor_id. Loading a hashed file with data is similar to loading a sequential file with data.

10 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

Properties for the hashed file stage are used to provide the physical location for the hashed file. If you use the Use account name checkbox and leave the account name box blank, the hashed file will be created in the same project in which the job creating it is executed. This provides flexibility for jobs that are moved from development to production environment. Alternatively, you can opt to specify the exact directory in which the hashed file will be created; however, if you place the file outside the area controlled by the DataStage engine (the project) you will not be able to backup the file using the DataStage Manager export project function.

10 - 5

Module 10 Defining Lookups

DataStage 314Svr

You should use the Key checkboxes to identify the keycolumns. If you dont, the first column definition is taken as the hashed files key field. The remaining columns dictate the order in which data will be written to the hashed file. Do not reorder the column definitions in the grid unless you are certain you understand the consequences of your action.

10 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

Once you have created a hashed file (using Director) you may want to import that hashed files meta data. Like all meta data imports, this is performed in DataStage Manager (import>table definitions>Universe File Definitions). Note that hashed files are known as Universe File Definitions.

10 - 7

Module 10 Defining Lookups

DataStage 314Svr

10 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

You can extract data from a hashed file: As a stream. As a lookup.

The process of extracting data from a hashed file as a stream is similar to extracting data from a sequential file. A hashed file stage used as a source has an additional tab called the Selection tab. Use it to specify a condition for filtering the data from the hashed file.

10 - 9

Module 10 Defining Lookups

DataStage 314Svr

10 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

Your job can delete a hashed file and then recreate it. To delete the file and then recreate it, select the Delete file before create box in the Create file options window on the hashed file target stage. To delete a hashed file without recreating it in a job, you can execute the DELETE.FILE command. To execute this command, log onto Administrator, select the project (account) containing the hashed file, and then click Command to open the Command Interface window. In the Command box, type DELETE.FILE followed by the name of the hashed file. Then click Execute. The DELETE.FILE command can also be executed in a Before/After Routine. (Before/After Routines are discussed in a later module.)

10 - 11

Module 10 Defining Lookups

DataStage 314Svr

Extracting data from a hashed file as a lookup involves several steps. The dashed line indicates reference input as opposed to stream input. Keep the following in mind: Reference lookups from hashed files must go into a Transformer stage. Multiple lookups can be done at the same Transformer. To specify an ordering, open the transformer and then click the Input Link Execution Order icon at the top. The procedure is the same as defining target link execution order. Lookups cannot be done from sequential files. Lookups can also be done from relational (ODBC) tables.

10 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

The lookup expression or join is defined in the transformer stage.

Click the right mouse button over the hashed file key column and select Edit Key Expression. This defines the value to look up in the hashed file.

10 - 13

Module 10 Defining Lookups

DataStage 314Svr

Any valid expression can be specified (not just a column mapping). You can drag input columns to the key column like when defining derivations for target columns.

Output from the lookup file is mapped to fields in the target link. If the lookup fails (the result of the expression is not found in the hashed file), NULLs are returned in all the lookup link columns. You can test for NULLs in a derivation to determine whether the lookup succeeded.

10 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

10 - 15

Module 10 Defining Lookups

DataStage 314Svr

10 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 10 Defining Lookups

10 - 17

Module 11

Aggregating Data

Module 11 Aggregating Data

DataStage 314Svr

11 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

The data sources youre extracting data from can contain many thousands of rows of data. You can summarize groups of data in each column using the functions listed below. Function Minimum Maximum Count Sum Average Standard deviation Description Returns the lowest value in the column. Returns the highest value in the column. Counts the number of values in the column. Sums the values in the column. Returns the average of the values in the column. Returns the standard deviation for the values in the column.

The first three functions (minimum, maximum, count) apply to non-numeric as well as numeric data. The last three only make sense when applied to numeric data.

11 - 3

Module 11 Aggregating Data

DataStage 314Svr

Heres an example of some data you might want to summarize. The Sales file contains a list of sales. You may want the following aggregations, for example: Total sales amount by store (by product, by year, by month, etc.) Average sales amount by store (by product, etc.) Total (average) quantity sold by product

11 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

In this example, we will determine the average sales amount for each product sold. The Sales stage is used to read the data. The transformer performs some initial calculations on the data. For instance, the sales amount for each order (qty * price) is calculated. Calculations cant be defined in the aggregator stage. The aggregator stage can have at most one input link and it cant be a reference link. In this example, the columns coming in include the product ID (product_id) and the sales amount (sales_amount) for each order. The output link will define the aggregations.

11 - 5

Module 11 Aggregating Data

DataStage 314Svr

This lists the main tasks in defining aggregations.

11 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

True or False? Suppose you want to aggregate over derived values. For example, you want to SUM(qty * unit_price). You can perform this derivation within the Aggregator True: Incorrect. You cannot perform derivations within the Aggregator stage. If you want to aggregate derived values, perform the the derivation in an output column in a prior Transformer stage. Then Aggegate over that incoming column in the Aggregator stage. False: Correct! You cannot perform derivations within the Aggregator stage. If you want to aggregate derived values, perform the the derivation in an output column in a prior Transformer stage. Then Aggegate over that incoming column in the Aggregator stage.

11 - 7

Module 11 Aggregating Data

DataStage 314Svr

The Inputs Columns tab specifies the incoming columns. Aggregations are performed in memory. If the data is presorted before it is aggregated, this can greatly improve the way in which the Aggregator stage handles the data. Use the Sort and Sort Order columns to specify whether and how the data is sorted. The Sort column is used to specify which columns are sorted and their order. For example, if the incoming data is sorted by stor_id and product_id, in that order, then stor_id would be column 1 and product_id would be column 2. In the Sort Order column specify the sort order, that is, whether the data is sorted in ascending or descending order or some other more complex ordering. The aggregator stage does not itself sort the data. Sorting must be performed in an earlier stage, for example, using an ODBC stage or sort plug-in.

11 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

Define the aggregation for each output column. Select the column(s) to group by. You will not be able to specify an aggregate function for the group by column(s).

11 - 9

Module 11 Aggregating Data

DataStage 314Svr

Double-click on the Derivation cell to open the Derivation window. This window is special in the aggregator stage. It allows you to select a column and an aggregate function for the column.

11 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

11 - 11

Module 11 Aggregating Data

DataStage 314Svr

11 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 11 Aggregating Data

11 - 13

Module 12

Job Control

Module 12 Job Control

DataStage 314Svr

12 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

Job parameters allow you to design flexible, reusable jobs. If you want to process data based on a particular file, file location, time period, or product, you can include these settings as part of your job design. However, if you do this, when you want to use the job again for a different file, file location, time period, or product, you must edit the design and recompile the job. Instead of entering inherently variable factors as part of the job design, you can set up parameters which represent processing variables. When you run or schedule a job with parameters, DataStage prompts for the required information before continuing. Job parameters can be used in many places in DataStage Designer, including: Passive stage file and table names. Passive stage directory paths. Account names for hashed files. Transformer stage constraints. Transformer stage derivations.

12 - 3

Module 12 Job Control

DataStage 314Svr

Recall this job. Customers from different countries are written out to separate files. The problem here is that the countries are hard-coded into the job design. What if we want a file containing, for example, Canadian customers? We can add a new output stage from the transformer and define a new constraint. Then recompile and run the job. A more flexible method is to use a parameter in the constraint in place of a specific country string such as USA. Then during runtime, the user can specify the particular country.

12 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

To define job parameters for a job, open the job in Designer and then click Edit>Job Properties. Click the Parameters tab on the Job Properties window.

12 - 5

Module 12 Job Control

DataStage 314Svr

Once a job parameter has been defined it can be used in various components of a job design to add flexibility. Candidate uses for a parameter are enumerated on this slide. To reference a job parameter two methods are used. If the value will be used in DataStage specific functions (such as value used with a constraint or derivation), simply supply the name of the parameter. If the value will be used in system functions (such as the location of file) the name of the parameter should be enclosed in # marks.

12 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

Since the file name is a value that is passed to the operating system for handling, the parameter is enclosed within # marks.

12 - 7

Module 12 Job Control

DataStage 314Svr

Since the value of the parameter will be used within a DataStage function (a constraint), the parameter name is used without enclosing # marks. In this example the developer simply right-clicked where the parameter should be placed, chose Job parameter, and will select from the dropdown list of parameters available in this job.

12 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

True or False? When job parameters are used in passive stages such as Sequential File stages, they must be surrounded with pound (#) signs. True: Correct! You must surround the name of the job parameter with pound signs. Otherwise, DataStage won't recognize it as a job parameter. False: Incorrect. You must surround the name of the job parameter with pound signs. Otherwise, DataStage won't recognize it as a job parameter.

12 - 9

Module 12 Job Control

DataStage 314Svr

12 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

Before and after routines are DS routines that run before or after a job and before or after a transformer. DS Before/After routines are defined in Manager. Three built-in Before/After routines are supplied with DataStage: ExecDOS, ExecSH, ExecTCL. These routines can be used to execute Windows DOS, UNIX, and UniVerse commands, respectively. The command, together with any output, is added to the job log as an informational message. You can also define custom Before/After routines. They are similar to other routines except that they have only two arguments: an input argument, an error code argument.

12 - 11

Module 12 Job Control

DataStage 314Svr

Click Edit>Job Properties on the Designer window or the Stage Properties button in a transformer or other active stage. In either case, a window is displayed in which you can select a Before/After routine and specify an input parameter. Input parameters can contain job parameters. In this example, the target file is copied to a temporary directory after the job runs using the standard Windows DOS copy command.

12 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

DataStage is supplied with a number of functions you can use to control jobs and obtain information about jobs. For detailed information about these functions, see Job Control in Help. These functions can be executed in the Job control tab of the Job Properties window, within DS routines, and within column derivations.

12 - 13

Module 12 Job Control

DataStage 314Svr

Here are some of the job control functions. BASIC Function DSAttachJob DSSetParam DSSetJobLimit DSRunJob DSWaitForJob DSGetProjectInfo DSGetJobInfo DSGetStageInfo Description Specify the job you want to control Set parameters for the job you want to control Set limits for the job you want to control Request that a job is run Wait for a called job to finish Get information about the current project Get information about the controlled job or current job Get information about a stage in the controlled job or current job

12 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

DSGetLinkInfo DSGetParamInfo DSGetLogEntry DSGetLogSummary DSGetNewestLogId DSLogEvent DSLogInfo DSStopJob DSDetachJob DSSetUserStatus

Get information about a link in a controlled job or current job Get information about a controlled jobs parameters Get the log event from the job log Get a number of log events on the specified subject from the job log Get the newest log event, of a specified type, from the job log Log an event to the job log of a different job Log an informatory message to the job log Stop a controlled job Return a job handle previously obtained from DSAttachJob Set a status message to return as a termination message when it finishes

12 - 15

Module 12 Job Control

DataStage 314Svr

The job control routines and other BASIC statements written in the Job control tab are executed after the job in which they are defined runs. This enables you to run a job that controls other jobs. In fact this can be all the job does. For example, suppose you want a job that first loads a hashed file and then uses that hashed file in a lookup. You can define this as a single job. Alternatively, you can define this as two separate jobs (as we did earlier) and then define a master controlling job that first runs the load and then runs the lookup.

12 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

Create an empty job and then click Edit>Job Properties. Click the Job control tab. Select the jobs you want to run one at a time in the Add Job box and then click Add. The job control functions and other BASIC statements are added to the edit box. Add and modify the statements as necessary. In this example: DSRunJob is used to run the load job. DSWaitForJob waits for the job to finish. You dont want the lookup to be performed until the hashed file is fully loaded. DSGetJobInfo gets information about the status of the job. If an error occurs the job is aborted before the lookup job is run.

12 - 17

Module 12 Job Control

DataStage 314Svr

12 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

The Job Sequencer enables you to graphically create controlling jobs, without using the job control functions. Job control code is automatically generated from your graphical design. Job Sequences resemble standard DataStage jobs. They consist of stages and links, like DataStage jobs. However, it is a different set of stages and links. Among the stages are Job Activity stages, which are used to run DataStage jobs. Links are used to specify the sequence of execution. Triggers can be defined on these links to specify the condition under which control passes through the link. There are other Activity stages, including: Routine Activity stages for execution a DataStage Routine. Execute Command stages for executing Windows, UNIX, or DataStage commands. Notification stages for sending email notifications.

12 - 19

Module 12 Job Control

DataStage 314Svr

Here is an example of a Job Sequence. The stages are Job Activity stages. The stage validates a job that loads a lookup hashed file. The second stage runs the job, if the validation succeeded. The third stage runs a job that does a lookup from the hashed file. The links execute these three stages in sequence. Triggers are defined on each of the links, so that control is passed to the next stage only if the previous stage executed without errors. To create a new Job Sequence click the New button and then select Job Sequence.

12 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

This shows a Job Activity stage. Select the job to run in the Job name box. Select how you want to run it in the Execution action box. The Parameters box lists all the parameters defined for the job. Select a parameter and then click Insert Parameter Value to specify a value to be passed to the parameter.

12 - 21

Module 12 Job Control

DataStage 314Svr

Triggers specify the condition under which control passes through a link. Select the type of trigger in the Expression Type. The types include: Unconditional: Pass control unconditionally. Otherwise: Pass control if none of the triggers on the links are executed. OK: Pass control if the job ran without errors or warnings. Failed: Pass control if the job failed. Warning: Pass control if the job ran with warnings. UserStatus: Pass control if the User Status variable contains the specified value. The User Status variable can be set in a job or Routine using the DSSetUserStatus job control function. Custom: Specify your own condition in DataStage Basic.

12 - 22 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

True or False? Triggers can be defined on the Job Activity Triggers tab for each Input link. True: Incorrect. Triggers are defined on Output links. They determine whether execution will continue down the link. False: Correct! Triggers are defined on Output links. They determine whether execution will continue down the link.

12 - 23

Module 12 Job Control

DataStage 314Svr

12 - 24 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

12 - 25

Module 12 Job Control

DataStage 314Svr

DataStage Containers encapsulate a set of job design components (stages and links) into a single stage icon. There are two kinds of Containers: Local and Shared. Local Containers only exist within the single job they are used. Use Shared Containers to simplify complex job designs. Shared Containers exist outside of any specific job. They are listed in the Shared Containers branch in Manager. These Shared Containers can be added to any job. Shared containers are frequently used to share a commonly used set of job components. A Job Container contains two unique stages. The Container Input stage is used to pass data into the Container. The Container Output stage is used to pass data out of the Container.

12 - 26 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

This shows the components that make up a example Container. The same job components are used with the exception of the Container Input stage, shown on the left, and the Container Output stage, shown on the right.

12 - 27

Module 12 Job Control

DataStage 314Svr

12 - 28 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

This shows a job with a Job Container (the stage in the middle). Data is passed into the Container from the link on the left. Data is retrieved from the Container in the link on the right. The Container processes the data using the set of stages and links it is designed with.

12 - 29

Module 12 Job Control

DataStage 314Svr

12 - 30 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 12 Job Control

12 - 31

Module 13

Working with Plug-Ins

Module 13 Working with Plug-Ins

DataStage 314Svr

13 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

A plug-in is a custom-built stage (active or passive) that you can install and use in DataStage in addition to the built-in stages. Plug-ins provide additional functionality without the need for new versions of DataStage to be released. Plug-ins can be written in either C or C++. Sample code is loaded in the /sample directory when DataStage is installed. A number of plug-ins are provided by Ascential. These include: Plug-in stages pre-installed with DataStage Found in Stage Types/PlugIn branch in Manager. Includes the Oracle bulk loader. Plug-in stages on the installation CD. These include: Additional bulk loaders. An ftp plug-in for accessing data using the ftp protocol. A sort plug-in for sorting data. A merge plug-in for integrating data. Plug-ins for accessing RDBMs, such as Oracle, through native drivers. Chargeable plug-in stages available from Ascential. These include:

13 - 3

Module 13 Working with Plug-Ins

DataStage 314Svr

External Data Access (EDA) for access to mainframe systems. Change Data Capture (CDC) for obtaining only changed records. Plug-in stages written to the DataStage C API may also be available from third-party vendors. Once a plug-in is installed you can use it in your jobs just as you can the builtin stages.

13 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

13 - 5

Module 13 Working with Plug-Ins

DataStage 314Svr

You can view installed plug-ins for a project in Manager.

13 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

Documentation for the plug-ins that come with DataStage is provided in PDF format on the DataStage installation CD. In addition, open the plug-in in Manager. The Stage Type window provides a variety of information in the four tabs: A description of the plug-in. Plug-in creator information. Plug-in dependencies. Plug-in properties.

Most of what you need to do when you use a plug-in in a job is to set its properties correctly. Plug-ins provide online documentation for each property when you open the Properties tab in Designer. The sort plug-in can have one input link and one output link. The input link specifies the records of data to be sorted. The output link outputs the data in sorted order.

13 - 7

Module 13 Working with Plug-Ins

DataStage 314Svr

13 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

This lists the main tasks involved in defining a sort using the DataStage Sort plugin.

13 - 9

Module 13 Working with Plug-Ins

DataStage 314Svr

The sort stage has three tabs: Inputs tab: Stage tab: sort. Specify the format of the data to be sorted. On the Properties sub-tab, you set the properties that define the Outputs tab: Specify the format of the data after its sorted.

13 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

True or False? Job parameters can be used in the Sort plug-in stage. True: Correct! Like when using job parameters in sequential stages, surround job parameters with # signs. False: Incorrect. Like when using job parameters in sequential stages, surround job parameters with # signs.

13 - 11

Module 13 Working with Plug-Ins

DataStage 314Svr

13 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 2 Working with Plug-Ins

13 - 13

Module 13 Working with Plug-Ins

DataStage 314Svr

13 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

Module 14

Scheduling and Reporting

Module 14 Scheduling and Reporting

DataStage 314Svr

14 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

Jobs are scheduled in Director. A job can be scheduled to run in a number of different ways: Once today at a specified time. Once tomorrow at a specified time. On a specific day and at a particular time. Daily at a particular time. On the next occurrence of a particular date and time.

Each job can be scheduled to run on any number of occasions and can be run with different job parameter values on the different occasions. Jobs run on the DataStage server under the user name specified on the Schedule tab in Administrator. If no user name is specified, it runs under the same name as the Windows NT Schedule service. If DataStage is running on Windows NT, DataStage uses the Windows NT Schedule service to schedule jobs. If you intend to use the DataStage scheduler, be sure to start or verify that the Windows NT Scheduler service is running. To start the NT Scheduler, open the Windows NT Control Panel and then open the Services icon. You can then manually start the service or set the service to

14 - 3

Module 14 Scheduling and Reporting

DataStage 314Svr

start automatically each time the computer is started.

14 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

True or False? When a scheduled job runs, it runs under the user ID of the person who scheduled it. True: Incorrect. When a user manually runs a job in Director, the job runs under the user ID of the person who manually started it. When a scheduled job runs, it runs under the user ID specified in Administrator. False: Correct! When a user manually runs a job in Director, the job runs under the user ID of the person who manually started it. When a scheduled job runs, it runs under the user ID specified in Administrator.

14 - 5

Module 14 Scheduling and Reporting

DataStage 314Svr

14 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

In addition to simple reports you can generate in Designer and Director using File>Print, DataStage provides a flexible and powerful reporting tool. The DataStage Reporting Assistant is invoked from DataStage Manager. You can generate reports at various levels within a project, including: Entire project Selected jobs Selected table definitions Selected routines and transforms Selected plug-in stages

Information generated for reporting purposes is stored in an ODBC database on the DataStage client. You can use this information for printing a report, writing a report to a file, or for browsing. By default, DataStage stores the reporting information in a Microsoft Access data source named DSReporting that is defined when the Reporting Assistant is installed.

14 - 7

Module 14 Scheduling and Reporting

DataStage 314Svr

This shows an example of a report created for a job.

14 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

This lists the main tasks involved in generating a report.

14 - 9

Module 14 Scheduling and Reporting

DataStage 314Svr

True or False? The DataStage Reporting Assistant stores the data it uses in its reports in an ODBC database. True: Correct! This data source is set up on your client machine when the DataStage clients are installed on your machine. False: Incorrect. This data source is set up on your client machine when the DataStage clients are installed on your machine.

14 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

14 - 11

Module 14 Scheduling and Reporting

DataStage 314Svr

14 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 14 Scheduling and Reporting

14 - 13

Module 14 Scheduling and Reporting

DataStage 314Svr

14 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

Module 15

Optimizing Job Performance

Module 15 Optimizing Performance

DataStage 314Svr

15 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

14 - 3

Module 15 Optimizing Performance

DataStage 314Svr

Collection of performance statistics for a particular job run is controlled from the DataStage Director client. Some overhead is consumed by the collection; therefore, job component percentages may not sum to 100% for every job run. Statistics are written to the job log and may be viewed as long as that log is preserved.

15 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

The collection of performance statistics can be turned on and off for each active stage in a DataStage job. This is done via the Tracing tab of the Job Run Options dialog box, select the stage you want to monitor and select the Performance statistics check box. Use shift-click to select multiple active stages to monitor from the list.

14 - 5

Module 15 Optimizing Performance

DataStage 314Svr

The first pane of the above frame contains a sample of a job log. When performance tracing is turned on a special log entry is generated immediately after the stage completion message. This is identified by the first line job.stage.DSD.StageRun Performance statistics. The second pane contains the detailed view of the statistics message; it is displayed in a tabular form. You can cut these and paste them into a spreadsheet if required to make further analysis possible. The performance statistics relate to the per-row processing cycle of an active stage, and of each of its input and output links. The information shown is: Percent. The percentage of overall execution time that this part of the process used. Count. The number of times this part of the process was executed. Minimum. The minimum elapsed time in microseconds that this part of the process took for any of the rows processed. Average. The average elapsed time in microseconds that this part of the process took for the rows processed.

You need to take care interpreting these figures. For example, when inprocess active stage to active stage links are used the percent column will not add up to 100%. Also be aware that, in these circumstances, if you collect statistics for the
15 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

first active stage the entire cost of the downstream active stage is included in the active-to-active link (as shown in our example diagram). This distortion remains even where you are running the active stages in different processes (by having inter-process row buffering enabled) unless you are actually running on a multiprocessor system.

14 - 7

Module 15 Optimizing Performance

DataStage 314Svr

You can improve the performance of most DataStage jobs by turning inprocess row buffering on and recompiling the job. This allows connected active stages to pass data via buffers rather than row by row. You can turn in-process row buffering on for the whole project using the DataStage Administrator. Alternatively, you can turn it on for individual jobs via the Performance tab of the Job Properties dialog box. Note: You cannot use in-process row-buffering if your job uses COMMON blocks in transform functions to pass data between stages. This is not recommended practice, and it is advisable to redesign your job to use row buffering rather than COMMON blocks.

15 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

Row buffering can be turned on in DataStage Administrator -- either as in process or inter process. Using Administrator to perform this function will set up row buffering as the project default. However, this can be overridden at the individual job level.

14 - 9

Module 15 Optimizing Performance

DataStage 314Svr

15 - 10 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

14 - 11

Module 15 Optimizing Performance

DataStage 314Svr

When you design a job you see it in terms of stages and links. When it is compiled, the DataStage engine sees it in terms of processes that are subsequently run on the server. How does the DataStage engine define a process? It is here that the distinction between active and passive stages becomes important. Actives stages, such as the Transformer and Aggregator, perform processing tasks, while passive stages, such as Sequential file stage and ODBC stage, are reading or writing data sources and provide services to the active stages. At its simplest, active stages become processes. But the situation becomes more complicated where you connect active stages together, and passive stages together.

15 - 12 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

What happens when you have a job that links two passive stages together? Obviously there is some processing going on. Under the covers DataStage inserts a cut-down transformer stage between the passive stages, which just passes data straight from one stage to the other, and becomes a process when the job is run. What happens where you have a job that links two or more active stages together? By default this will all be run in a single process. Passive stages mark the process boundaries, all adjacent active stages between them being run in a single process.

14 - 13

Module 15 Optimizing Performance

DataStage 314Svr

This job is comprised of two processes because of the second sequential stage.

15 - 14 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

14 - 15

Module 15 Optimizing Performance

DataStage 314Svr

SMP Symmetric Multi-Processors, multiple CPUs with single shared operating system and shared memory. Examples: Sun Starfire, IBM S80, Compaq GS Series, HP Superdome MPP multiple independent systems connected by a high-speed network, some nodes may be SMP. Each node has dedicated resources. Clusters a group of connected computers NUMA Non Uniform Memory Access, tightly coupled cluster which uses shared memory and local memory To achieve muli-processing you not only need multi-processing hardware but you also need applications that were built to multi-process.

15 - 16 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

Data pipelining requires the same transform on all partitions; this can be easily accomplished using containers. Data pipelining and data partitioning can occur simultaneously within a job.

14 - 17

Module 15 Optimizing Performance

DataStage 314Svr

If you split processes in your job design by writing data to a Sequential file and then reading it back again, you can use an Inter Process (IPC) stage in place of the Sequential stage. This will split the process and reduce I/O and elapsed time as the reading process can start reading data as soon as it is available rather than waiting for writing process to finish.

15 - 18 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

Normally this would be a single process but with the introduction of the IPC stage this job will split the read operation into one process and the transform and write into another process. Meta data must be the same on both the input and output links to the IPC stage.

14 - 19

Module 15 Optimizing Performance

DataStage 314Svr

The Properties tab allows you to specify two properties for the IPC stage: Buffer Size. Defaults to 128 Kb. The IPC stage uses two blocks of memory; one block can be written to while the other is read. This property defines the size of each block, so that by default 256 Kb is allocated in total. Timeout. Defaults to 10 seconds. This specifies a time limit for how long the stage will wait for a process to connect to it before timing out. This normally will not need changing, but may be important where you are prototyping multiprocessor jobs on single processor platforms and there are likely to be delays.

15 - 20 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

14 - 21

Module 15 Optimizing Performance

DataStage 314Svr

With the introduction of the enhanced multi-processor support at Release 6, there are opportunities to further enhance the performance of server jobs by partitioning data. The Partitioner stage allows you to partition data you are reading so it can be processed by individual processors running on multiple processors. The Collector stage (appears to the right of this diagram) allows you to collect partitioned data together again for writing to a single data target. Inter-process row buffering should be turned on.

15 - 22 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

This example shows the partitioner stage depicted in the previous frame. Note: meta data on the output and input links must be identical.

14 - 23

Module 15 Optimizing Performance

DataStage 314Svr

Algorithms: Round-Robin. This is the default method. Using the round-robin method the stage will write each incoming row to one of its output links in turn. Random. Using this method the stage will use a random number generator to distribute incoming rows evenly across all output links. Hash. Using this method the stage applies a hash function to one or more input column values to determine which output link the row is passed to. Modulus. Using this method the stage applies a modulus function to an integer input column value to determine which output link the row is passed to. Partitioning Key. This property is only significant where you have chosen a partitioning algorithm of Hash or Modulus. For the Hash algorithm, specify one or more column names separated by commas. These keys are concatenated and a hash function applied to determine the destination output link. For the Modulus algorithm, specify a single column name which identifies an integer numeric column. The value of this column value determines the destination output link.

15 - 24 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

The Collector stage is an active stage, which takes up to 64 inputs and allows you to collect data from these links and route it along a single output link. The stage expects the output link to use the same meta data as the input links. The Collector stage can be used in conjunction with a Partitioner stage to enable you to take advantage of a multi-processor system and have data processed in parallel. The Partitioner stage partitions data, it is processed in parallel, then the Collector stage collects it together again before writing it to a single target.

14 - 25

Module 15 Optimizing Performance

DataStage 314Svr

The Properties tab allows you to specify two properties for the Collector stage: Collection Algorithm. Use this property to specify the method the stage uses to collect data. Choose from: oRound-Robin. This is the default method. Using the round-robin method the stage will read a row from each input link in turn. oSort/Merge. Using the sort/merge method the stage reads multiple sorted inputs and writes one sorted output. Sort Key. This property is only significant where you have chosen a collecting algorithm of Sort/Merge. It defines how each of the partitioned data sets are known to be sorted and how the merged output will be sorted.

15 - 26 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 15 Optimizing Job Performance

The partitioner stage can support up to 64 output links and the collector can support up to 64 input links. Meta data should be identical on input and output links to the partitioner; similarly for the collector stage. This configuration can also use a container in place of the transformer.

14 - 27

Module 15 Optimizing Performance

DataStage 314Svr

15 - 28 Copyright 2002 Ascential Software Corporation 09/01/02

Module 16

Putting It All Together

Module 16 Putting It All Together

DataStage 314Svr

16 - 2 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 16 Putting It All Together

16 - 3

Module 16 Putting It All Together

DataStage 314Svr

Our final application will use a business data mart for source data. Data will be extracted, go through little or no data transformation, get summarized and loaded into a target database. The reason that little or no data transformation will occur is that the data has already been cleaned before being loaded into the data mart.

16 - 4 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 16 Putting It All Together

The existing data mart consists of a star schema structure comprised of a sales fact table surrounded by promotion, store, product, and time dimensions. The time dimension has been renamed to timex because of naming convention limitations within Microsoft Access; similarly be date field has been renamed to datex. A star schema, such as the one depicted above, is an ideal data structure for ad hoc queries. Many vendor tools are available in the marketplace to support this type of query building. Note that the dimensions are linked to the fact table by surrogate keys. We will use the surrogate keys to build DataStage jobs that denormalize the data.

16 - 5

Module 16 Putting It All Together

DataStage 314Svr

The desired result from end-users is a table, or set of tables, get summarized the data by specific dimensions. This video will briefly demonstrate the actions a typical end-user might employ with the summary tables. Be

16 - 6 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 16 Putting It All Together

16 - 7

Module 16 Putting It All Together

DataStage 314Svr

16 - 8 Copyright 2002 Ascential Software Corporation 09/01/02

DataStage Essentials

Module 16 Putting It All Together

16 - 9

Module 16 Putting It All Together

DataStage 314Svr

16 - 10 Copyright 2002 Ascential Software Corporation 09/01/02