Sunteți pe pagina 1din 100

All rights reserved.

Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

Site LANNION

TECHNICAL DEPARTMENT

Originators Lahay J.M

CATALOG OF MESSAGES SRFIL RECSRFIL

Domain Division Rubric Type Distribution Codes

: : : :

ALCATEL E10B Operating document Catalog Internal :

External

PREDISTRIBUTION

ABSTRACT
The document describes all the messages listed by SRFIL.

Approvals Name App.

Name App.

REVIEW
None

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04

VALIDATED 3BW 60437 AAAA RKAHA 2 Y 1/ 2

CIT

HISTORY
01 dated 010315 Creation based on AAC026321400UG Ed. 01 Review report: SSD/TD/DLO/DNE/LBB/00.322 02 dated 010531 Notices 03 dated 010828 RT 01E101002600 Notices 04 dated 030428 Notices

END OF DOCUMENT

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04

VALIDATED 3BW 60437 AAAA RKAHA 2 Y 2/ 2

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

CATALOG

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

TABLE OF CONTENTS
HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INTERPRETATION OF DEPENDABILITY OBSERVATION MESSAGES . . . . . . . . . . . . . . . . . . . 1.1 What is dependability observation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 When to use SRFIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 How to use SRFIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.1 Online help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.2 Criteria for searching the log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.3 Outputting additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.4 List of events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 How to interpret the results of SRFIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.1 Standard format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.2 Format with the DBG=H1 option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.3 Interpreting an SRFIL event . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.4 Station, ML state codes (pe_se) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.5 System state codes (es_ni) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DETAILED ANALYSIS OF THE INFORMATION OUTPUT BY SRFIL DBG=H1 . . . . . . . . . . . . 2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.1 System address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.2 Station identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.3 Archive identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.4 Board or applique identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.5 ML component identification (subaddress) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 CODM=0000 (XDRQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 CODM=AC11 (DPOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 CODM=AE11 (FPOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 5 5 5 5 5 6 7 7 9 9 9 10 12 13 14 15 15 15 16 17 18 20 20 20 21 21 21 23 23 23

04 01
1AA 00014 0004 (9007) A4 ALICE 04.10

030428 010315 DATE CHANGE NOTE DSYS/DEV APPRAISAL AUTHORITY

DVI/DEX/PRX DSYS/DEV/DNE ORIGINATOR

ED

CATALOG OF MESSAGES SRFIL RECSRFIL

ED

04 3BW 60437 AAAA RKAHA 97 1 / 97

CIT

1AA 00014 0004 (9007) A4 ALICE 04.10

2.5 CODM=AE91 (FTEST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 CODM=AF10 (OTOPH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 CODM=AF16 (OGADI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7.3 Translation of sfadrgad on a board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 CODM=AF20 (OINET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9 CODM=AF23 (ODICH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9.3 Load state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10 CODM=AF30 (OINCI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11 CODM=AF40 (ORIPO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12 CODM=AF41 (OSETA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13 CODM=AF44 (OSETE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14 CODM=AF61 (ORPOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15 CODM=AF63 (OTECH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15.3 Detection point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16 CODM=AF71 (OPOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17 CODM=AF73 (OETER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.3 Positioning by operator command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.4 Switchover to standby TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.5 Return to normal TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17.6 Switchover to standby TU failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.18 CODM=AF80 (OIDEF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.18.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.18.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19 CODM=AF82 (OSYNP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.20 CODM=AF90 (OMIDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.20.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

25 25 26 28 28 28 28 29 29 29 30 30 30 31 31 31 34 34 34 35 35 35 36 37 37 37 38 38 38 39 39 40 47 47 47 48 50 50 50 50 50 52 58 59 59 59 59 60 60 60 61 61 61 61

ED

04 3BW 60437 AAAA RKAHA 97 2 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.20.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.21 CODM=AFA1 (OMCOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.21.1 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.21.2 Coding of the additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX A LIST OF SYSTEM AS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.1 List of system AS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX B FAILURE CAUSES (INITIALIZATION AND POSITIONING) . . . . . . . . . . . . . . . . . . . B.1 Common . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.2 SMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.3 ML TR, TX, MQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.4 ML COM1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.5 MLGX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.6 ML COM2G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.7 ML HD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.8 ML PC, ML PUPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.9 ML MR, CC, GS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.10 ML URM2G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.11 ML URM1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.12 ML AN, MGI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.13 ML ETA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX C PDIA : LOCAVAR DIAGNOSTIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C.1 Station Locavar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C.2 ETU Locavar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX D LIST OF ANOMALIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX E MAIN MLSM NUMANO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61 63 63 64 67 67 68 68 70 73 74 75 76 76 77 81 81 83 83 88 89 89 91 92 95

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 3 / 97

CIT

HISTORY
01 dated 010315 Creation. 02 dated 010531 Notices 03 dated 010828 RT 01E101002600 04 dated 030428 Notices

PREFACE
This document provides the information needed to analyze the events reported and output by the dependability observation function (restricted use command SRFIL).

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 4 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

1 INTERPRETATION OF DEPENDABILITY OBSERVATION MESSAGES 1.1 What is dependability observation


Dependability observation provides a log of all the systems defense actions. This function is handled by central defense which records the information relating to the systems defense actions. For each defense action, central defense records one or more events so that the source of the action can be stored and the procedure monitored. Each basic event contains the following information: Event number: characterizes the defense action. Date and time. Identification of the item concerned, usually a station. The state of the item before the defense action. Additional information: usually this is the message originating the defense action. The events are stored in an OM file. This is a circular file, with new events overwriting the oldest ones. The file is used to keep a record of one or more months. This log is operated using the SRFIL command. SRFIL parameters define the criteria for searching the log. You can therefore search for a type of event, events occurring in a particular timeband, or events relating to a station.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

1.2 When to use SRFIL


To analyze the stability of a site This way, you can ascertain the number of station crashes in a given period, the type of station concerned, and the origin and you can generate statistics and check whether the system complies with operating standards. This information may also be useful before extending a site or installing a new version. To analyze a site incident After the fact, you can reconstruct the scenario of the incident, determine its origin and duration and establish a correlation between the events and other manifestations of the incident (alarms, etc). To send information to the manufacturer When an incident requires the manufacturers intervention, the log provides the basic information sent to the manufacturer for analysis.

1.3 How to use SRFIL


1.3.1 Online help The SRFIL command provides a minimal online help facility which gives the general syntax of the command and the event codes. To obtain help, execute the SRFIL command (see FOP <SRFIL>) before the HELP parameter.

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 5 / 97

CIT

1.3.2 Criteria for searching the log The SRFIL parameters are used to search for events that match one or more criteria. PARAMETER EVT Event number Arithmetical list Hardware address Arithmetical list ML functional address Arithmetical list Timeband start date In the form yymmdd If DD is omitted and HD is present, DD automatically takes the current date HD Timeband start time In the form hhmm If HD is omitted and DD is present, HD automatically takes the value 0H00 DF Timeband end date In the form yymmdd If DF is omitted and HF is present, DF automatically takes the current date HF Timeband end time In the form hhmm If HF is omitted and DF is present, HF automatically takes the value 23H59 For listing events occurring before the specified time For listing events occurring before the specified date For listing events occurring after the specified time MEANING USE For listing the events that have one of the specified numbers For listing the events concerning the specified SMs For listing the events relating to the stations supporting the specified MLs For listing the events occurring after the specified date
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

AM

AF

DD

If you want to... search in a timeband search for events by number search for events concerning a station search for events supporting an ML concerning the

then... enter the DD, HD, DF and HF parameters enter the EVT parameter enter the AM parameter station enter the AF parameter

1AA 00014 0004 (9007) A4 ALICE 04.10

search according to several criteria (timeband, enter the timeband parameters (DD, HD, DF, HF) event, etc) and/or the event number parameters (EVT) and/or station parameters (AM or AF) stop a listing that is too big enter CTRLA

ED

04 3BW 60437 AAAA RKAHA 97 6 / 97

CIT

1.3.3 Outputting additional information When the log is interrogated, all events matching the criteria specified in the SRFIL parameters are listed in a format which gives the date and time, the number and description of the event, the address of the station concerned, its state and the list of MLs assigned to it. If you enter DBG=H1 as an SRFIL command option, you also obtain the events output header in hexadecimal code. You can then access the manufacturers additional information. 1.3.4 List of events 0 Station taken out of service on fault. Indicates that a station has been automatically taken out of service. Station out of service before reconfiguration. Indicates that a standby station has been set to BLO ready for reconfiguration. Start of station initialization. Indicates the start of initialization of a station. End of station initialization. Indicates the end of initialization of a station. Start of automatic LOCAVAR. Indicates the start of an automatic LOCAVAR routine. End of automatic LOCAVAR. Indicates the end of an automatic LOCAVAR routine. Source reconfiguration. Indicates that the stations reconfigurable MLs have been transferred to another station. Destination reconfiguration. Indicates that the station has taken the reconfigurable MLs from another station. Initialization failure. Indicates a station initialization failure. Operator command positioning failure. Indicates the failure of a station positioning by an operator command. Start of positioning by operator command. Indicates that a positioning by operator command has been accepted. End of positioning by operator command. Indicates that a positioning by operator command has finished executing. Start of LOCAVAR by operator command. Indicates the start of a LOCAVAR routine by operator command. End of LOCAVAR by operator command. Indicates the end of a LOCAVAR routine by operator command. Start of DUMP. Indicates the start of a stations memory dump.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

10

11

12

13

1AA 00014 0004 (9007) A4 ALICE 04.10

14

ED

04 3BW 60437 AAAA RKAHA 97 7 / 97

CIT

15

End of DUMP. Indicates the end of a stations memory dump.


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

16

SM disconnected from communication multiplex. Indicates that a station has been disconnected from the multiplexes. Occurs when positioning the station to BLO fails. Activation of general reinitialization. Indicates automatic activation of the systems general initialization function. SMM switchover. Indicates an active SMM is out of service or an initialization failure. End of central defense initialization. Indicates the end of central defense initialization. General restart activation. Indicates the automatic activation of the systems general restart function. Positioning message transmission. Indicates the transmission of a station positioning message. SM creation. Indicates the creation of a station by an extension operator command. SM deletion. Indicates the deletion of a station by extension operator command. System status broadcast. Indicates that the systems state or level is being broadcast; the broadcast reflects a change of state or system level during general initialization, general restart, change of release or rebroadcast procedures during central defense initialization. ML switchover. Indicates that a duplex ML is switching from standby to active. Overload event. Indicates a change of overload state, plots an overload event. ETP automatically out of service on fault. Indicates that an ETP has been taken out of service automatically due to a fault. End of automatic LOCAVAR of ETP with failure. Indicates the end of an automatic LOCAVAR routine on an ETP with the ETP having failed. ETU positioning by operator command. Indicates the positioning of an ETU by operator command. End of automatic ETP initialization. Indicates the end of automatic initialization of an ETP. Switchover to standby ETU. Indicates switchover from an ETU to the standby ETU. Return to normal ETU. Indicates switchover from a standby ETU to the normal ETU.

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31
1AA 00014 0004 (9007) A4 ALICE 04.10

32

ED

04 3BW 60437 AAAA RKAHA 97 8 / 97

CIT

33

Switchover to standby ETU failed. Indicates the failure of a switchover from an ETU to the standby ETU. External server instance state transition. Indicates the change of state of one or more instances of an external server.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

34

1.4 How to interpret the results of SRFIL


1.4.1 Standard format 1) General case yymmdd/hh H mn MN ss EVT=ee :lllllllllllllllllll /AM=am STT.=etat AF=af 2) Event 24 yymmdd/hh H mn MN ss EVT=24 :DIFF.SYS STAT. etasnivs 3) Event 34 yymmdd/hh H mn MN ss EVT=34 :SER. EXT. STT. MOD. yymmdd hh H mn MN ss Date Hour, minute and second

ee :llllllllllllllllll Number and description of the event etasnivs am etat System state and operating level Station hardware address Station state The state of the station before the event occurred Functional address of the MLs assigned to the station These are the MLs assigned to the SM before the event occurred

af

Example: 001024/16 H 31 MN 11 EVT=00 :SET TO OOS (FAULT) /AM = SMC6 STT.=ES AF=TX2+PCB

1.4.2 Format with the DBG=H1 option 1)


1AA 00014 0004 (9007) A4 ALICE 04.10

General case yymmdd/hh H mn MN ss EVT=ee :lllllllllllllllllll /AM=am STT.=etat AF=af / 02ee yymm ddhh mnss lim0 lim1 lim2 lim3 lim4 lim5 lim6 lim7 / peco dmii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii

ED

04 3BW 60437 AAAA RKAHA 97 9 / 97

CIT

/ iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii / iiii iiii iiii iiii iiii iiii iiii iiii iiii ii
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2)

Event 24 yymmdd/hh H / 02ee yymm / esco dmii / iiii iiii / iiii iiii mn MN ss EVT=24 :DIFF.SYS STAT. etasnivs ddhh mnss 0000 0000 0000 0000 0000 0000 0000 00ni iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii ii

3)

Event 34 yymmdd/hh H / 02ee yymm / esco dmii / iiii iiii / iiii iiii yymmdd mn MN ss EVT=34 :SER. EXT. STT. MOD ddhh mnss 0000 0000 0000 0000 0000 0000 0000 00ni iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii iiii ii Date Hour, minute and second

hh H mn MN ss

ee :llllllllllllllllll Number and description of the event etasnivs System state and operating level The system state is given for event 24 only es, ni (see 1.4.4 page 12) Station hardware address lim0 Station state The state of the station before the event occurred pe (see 1.4.4 page 12) Functional address of the MLs assigned to the station These are the MLs assigned to the SM before the event occurred lim1, lim2, lim3,lim4,lim5, lim6,lim7 When the station supports more than 8 MLs, lim2 is in the form 1nnn and the list of MLs is then given by record nnn of the FELML file in the ZSM archive Message class and code This field is for decoding the additional information Additional information in hexadecimal The length and structure of the information depends on codm

am

etat

af

codm

iiii

1.4.3 Interpreting an SRFIL event


1AA 00014 0004 (9007) A4 ALICE 04.10

Usually, an SRFIL event should be read as follows

ED

04 3BW 60437 AAAA RKAHA 97 10 / 97

CIT

On yymmdd at hh H mn MN ss, the codm message generated event evt on station am which was in the etat state.
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

Example: 001024/16 H 31 MN 11 EVT=00 :SET TO OOS (FAULT) /AM = SMC6 STT.=ES AF=TX2+PCB / 0200 0010 2416 3111 0309 010B 0151 0000 0000 0000 0000 0000 / 11AF 6100 0009 0800 0000 0000 0000 0000 0500 FF00 0000 0000 / 0000 00

In the above example, read: on 001024 at 16 H 31 MN 11, the message AF61 generated event EVT=00 :SET TO OOS (FAULT)on station SMC6 supporting ML TX2 +PCB which was ES. When interpreting SRFIL, be careful because the message that generated the event may not concern the station specified. Example: 001013/17 H 50 MN 02 EVT=02 :START INITIALIZAT. /AM = SMC2 STT.=BLOS AF=TR2+MQ2+GX2+PCB+MR2+CC2+GS2 / 0202 0010 1317 5002 0305 010A 0109 017D 0151 010C 02A9 02C9 / 12AE 1100 0003 0812 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00 In the above example, read on: 001013 at 17 H 50 MN 02, the message AE11 generated event EVT=02 :START INITIALIZAT. on station SMC2 supporting ML TR2 +MQ2 +GX2 +PCB +MR2 +CC2 +GS2 which was BLOS; the message AE11 relates to a station other than SMC2.

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 11 / 97

CIT

1.4.4 Station, ML state codes (pe_se) symbol pe structure posp : 4 code Primary positioning; for an ML SM, it is the operator state 0 Not equipped (NEQ) 1 In service (ES) 2 Manually blocked (BLOM) 3 Unavailable (INDL) Primary positioning; for an application ML, it is not used 0 Current state; for an ML SM 0 Not equipped 1 In service 2 Blocked 3 Unavailable busy 4 Unavailable free 5 Initializing 6 Loading 7 Under test 8 Failed Current state; for an application ML 0 Not in service 1 In service 3 Unavailable busy 4 Unavailable free 5 Initializing 6 Loading Standby indicator, for an application ML 00 Active 80 Standby
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

etac : 4

se

sec : 8

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 12 / 97

CIT

1.4.5 System state codes (es_ni) symbol


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

code System state 1 In service 2 General initialization 3 General restart 8 In change of release

es

etas : 4

(ES) (INIGi) (REGEi) (CDPC, CDPIi)

iac : 4

Progress indicator, general initialization 0 OM initializing 1 Command functions initializing 2 Network functions, auxiliary equipment and terminations initializing 3 Initialization time, LD, N7 Progress indicator, general restart 0 OM initializing 1 Command functions initializing 2 Auxiliary functions initializing 3 N7 initializing Progress indicator, incompatible change of release 1 Initializing subsystem A 2 Switching over to new release System operation level 00 Operational 01 Filtering active in incompatible change of release 10 Network initialized 20 Network ML initialized 30 Command initialized 40 OM initialized 80 OM initializing

ni

nivs : 8

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 13 / 97

CIT

2 DETAILED ANALYSIS OF THE INFORMATION OUTPUT BY SRFIL DBG=H1


For a detailed analysis of the events the additional information must be decoded. The additional information usually comes from an OCB283 message received or sent by central defense. The table below gives the codm codes of the messages stored. It is from codm that the additional information can be analyzed. CODM 0000 Name XDRQ Purpose of message Command request Relating to the ESMMO, SMTL and CHNMO commands. SM state positioning request Used to initialize, position a system, activate locavar tests. This is a message sent by central defense. End of positioning deferred message Signals the end of station initialization or positioning. Deferred response to a test positioning request Indicates the end of the locavar tests. Timeout Adapter out of service diagnostic message Take out of service request sent by the ring manager at the end of testing a ring using AMXMO. Inconsistent state signal Take out of service request sent by the MLOC when a stations internal state does not match the state given in the FTET file. Load state broadcast Indicates a change in the systems load state. Internal inconsistency signal Request to take the active SMM out of service. This message may come from the LCC in the absence of a message (serious coupler fault) or from the ML OC when it detects a large number of state inconsistencies or SM inaccessible occurrences. SM positioning internal request This message is used: By the anomaly statistics handling process to indicate that the statistics counters have overflowed. By an ML to ask for another ML to be taken out of service (eg: PUPE penalty posting by the PC). By the MLOC to indicate that a station is inaccessible; usually this involves a serious fault, not indicated by the station, or a main coupler failure (power supply, etc). Change of state indication Message sent every time an ML changes state. Service instance state change Message sent every time a server instance changes state.

AC11

DPOS

AE11

FPOS

AE91

FTEST

AF10 AF16

OTOPH OGADI

AF20

OINET

AF23

ODICH

AF30

OINCI

AF40

ORIPO

AF41
1AA 00014 0004 (9007) A4 ALICE 04.10

OSETA

AF44

OSETE

ED

04 3BW 60437 AAAA RKAHA 97 14 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

CODM AF61
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

Name ORPOS

Purpose of message SM positioning request This message is sent by a stations local defense to indicate: A serious fault (selfpositioning). A soft fault. A permanent abnormal overload. Load event trace SM system blocked transition signal This message indicates the end of an SM returning to PROM. If the station was in service, it is a serious fault not indicated by the station. Terminationrelated event This message is used by the ETU handler to indicate events relating to the ETUs. Central defense initializing This message appears every time the active SMM is initialized; it follows an SMM switchover on an operator request or a fault. Synchronization This message indicates the end of network initialization. Central defense internal message Used for a dump, change of release or change of system state. Configuration modification indication Indicates a reconfiguration on a standby station, a creation or deletion of an SM.

AF63 AF71

OTECH OPOS

AF73

OETER

AF80

OIDEF

AF82

OSYNP

AF90

OMIDC

AFA1

OMCOS

2.1 General
2.1.1 System address All elements of the system are identified internally by a system address (as) on 12 bits. Appendix A page 67, lists the system addresses and their associated external elements. The name of an element can be read by interrogating the BKOR file with the as number. 2.1.2 Station identification A station is identified externally by a name (eg: SMB1) and internally by a physical address (apsm) and one or two system addresses (assm). A pair of stations operating in duplex mode is also identified externally by a name (eg: SMT1); each pair of stations supporting ETUs has a group system address.

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 15 / 97

CIT

AS 302303 30433F 340341 ..... 34E34F 36039F 3E03E1 .... 41E41F 420421 .... 45E45F 460461 .... 47E47F 4804D7 54D56C 56D58C

AS (*)

AP 002003 00403F 040041 ..... 04E04F 06009F 0E00E1 .... 11E11F 120121 .... 15E15F 160161 .... 17E17F 1801D7

Station SMMASMMB SMC1SMC60 SMXA1SMXB1 .... SMXA8SMXB8 SMA1SMA64 SMTA1SMTB1 .... SMTA32SMTB32 SMBA1SMBB1 .... SMBA32SMBB32 SCHA1SCHB1 .... SCHA16SCHB16 SMB1SMB88 SMT1SMT32 SMBD1SMBD32

C20C21 .... C5EC5F

C80CD7

(*) SMBs have a second internal system address used for addressing components 16 to 31 of the station. 2.1.3 Archive identification An archive is identified on the operator interface by a name (eg: ZSM) which corresponds internally to a type of ML (tyml) and a type of archive (sarc).

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 16 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

tyml 01
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

ML MQ PUPE MR TX TR PC OC ETA COM1G URM1G GX SM

sarc 0 1 0 1 0 1 0 1 0 1 1 1 1 1 0 1 2 1 1 1 1 1 1 1 1 1 1

archive XAMQ ZMQ XUTC ZMR XATX ZTX XATR ZTR XUTC ZOC ZETA ZCOM ZURM ZGX XASM ZSM ZLO ZURM2 ZSABA ZLI ZCC ZGS ZCOM2 ZAN ZHD ZGW ZMGI

02 03 04 05 06 07 08 09 0A 0E 0F

10 12 14 15 16 17 18 19 1A 1B

URM2G SABA ZLI CC GS COM2G AN HD GW MGI

2.1.4 Board or applique identification Each of the stations boards or appliques is identified physically by a board number (rgca) and functionally by a function (sfca) and a number in the function (rgsf). The SMIL command lists a stations configuration. A software map describes a software components assignment to a sfcargsf pair. In non HC technology, a software map describes the assignment of a software component to a sfcargsf pair. On an SMB, a board or applique has several identifiable hardware elements. A hardware element is identified physically by the rgca and an element number on the board or applique (rgem) and functionally by a hardware function (sfem) and a number in the function (rgfm). A software map describes the assignment of a software component to a sfemrgfm pair. Within a station, each hardware element has an identifier (fmid) on 32 bits which is structured as follows: 31 rgca
1AA 00014 0004 (9007) A4 ALICE 04.10

24 27 rgem

16 15 idl

Only the following boards or appliques have more than one rgem:

ED

04 3BW 60437 AAAA RKAHA 97 17 / 97

CIT

board/applique AATRA

rgem 00 = Adapter A 01 = Adapter B 00=PPC 01=PQUICC A (MPRQT) 02=PQUICC B (MPRQT) 03=PQUICC C (MPRQ) 00=PQUICC 0 (AUXQ3I) 01=PQUICC 1 (AUXQ2I) 02=PQUICC 2 (AUXQAH)

ACMPR

ACAUX

The MAPIL command with AM=<am> and NIV=1 is used to list a stations hardware elements. 2.1.5 ML component identification (subaddress) On a station, an ML is made up of components. A component is defined by a tyml and a component type (tyco). A station may support several components of the same type. Each ML component has a 16bit address that consists of the 12 bits of the MLs as and four subaddress bits (sad). 15 14 13 sad 12 11 10 9 8 7 6 5 asml 4 3 2 1 0

Example: 310C

subaddress=3 and as ml=10C

On an SMB, there may be 32 MLSM components for each station; each mslm has two asml, the first to address components 0 to 15 and the second to address components 16 to 31. Example: 4481 8C81 subaddress=4, as ml=481 subaddress=18, as ml=481

2.1.5.1 Old technology The subaddress of an MLSM component identifies its function. sad 0 1 2 3 4 to 7 8 to B C to F function and number in the function Main coupler (CMP) Main processor (PUP) ETU manager Debug support Secondary coupler 03 (CMS 03,MAS14) Secondary processor 03 (PUS 03) Achill coupler 03 (CSS7 03)

1AA 00014 0004 (9007) A4 ALICE 04.10

The ARCIN command with, AM=<am>,ARCH=ZSM, NFIC=69, NUM=0<31, CHSE=ASML+TYML+TYCO+NAGT+SFCA: lists a stations software configuration.

ED

04 3BW 60437 AAAA RKAHA 97 18 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.1.5.2 SMB The subaddress of an MLSM component does not identify its function.
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

subaddress 0 2 3 1,4 to 1F

function and number in the function Main coupler (CMP) ETU manager Troubleshooting Dependent on software configuration

The ARCIN command with AM=<am>,ARCH=ZSM, NFIC=419, NUM=0<63, CHSE=ASML+TYML+TYCO+FMIDL+SFCA+RGSF; lists a stations software configuration. 2.1.5.3 Application ML tyml MQ PUPE subaddress 0 0 1 2 to 5 0 1 to 4 0 1 to 4 0 0 1 0 0 0 0 0 0 1 0 1 to 4 0 1 to 4 0 component MQ PUPEN PUPEI PUPEL MRP MRM TXP TXM TR PCN PCI OC ETA COM URM GX URM2GP URM2GS CCP CCS GSP GSS COM2G

MR

TX

TR PC

OC ETA COM1G URM1G GX URM2G

CC

1AA 00014 0004 (9007) A4 ALICE 04.10

GS

COM2G

ED

04 3BW 60437 AAAA RKAHA 97 19 / 97

CIT

tyml AN

subaddress 0 1 to 4 0 0 0 1 to 4

component ANP ANL HD GW GI_P GI_S

HD GW MGI

2.2 CODM=0000 (XDRQ)


Request from an operator command. 2.2.1 Example 001102/18 H 21 MN 16 EVT=10 :START OF POSIT(MMC) /AM = SMBA1 STT.=ES AF=COMA1+URMA1+HDA1 / 020A 0011 0218 2116 0420 0120 0200 0CD8 0000 0000 0000 0000 / 1100 0000 0104 2001 00FF 00 2.2.2 Coding of the additional information / 1100 0000 0104 2001 00FF 00 tyrq : 16 Request type 1 Change state (ESMMO, CHNMO) 4 Locavar (SMTL) 5 Create SM (SMCR, SMBCR) 6 Delete SM (SMSU, SMBSU) 8 Change release (CDPLA)

/ 1100 0000 0104 2001 00FF 00 assm : 16 SM system address (see Appendix A.1 page 67)

/ 1100 0000 0104 2001 00FF 00 etad : 8 Requested state 01 BLOM 02 INDL 03 ES

/ 1100 0000 0104 2001 00FF 00

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 20 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

tych : 8

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

For changing state, loading type 00 Counterpart 01 OM 02 Change of release 03 No loading 04 Reconfigure catalogs FF No meaning For locavar, locavar type 00 Normal 01 Complete locavar (duplex ETU) 02 Factory locavar 03 01 +0 2

/ 1100 0000 0104 2001 00FF 00 conf : 8 Confirmation 00 Confirmed 01 To be confirmed

2.3 CODM=AC11 (DPOS)


The positioning message sent by central defense to a station. This event usually follows a 2, 4, 10, 12 or 0 event. Located after an SMM switchover, this event tells whether a station was HS before the SMM switchover or had gone HS while the SMM was absent. 2.3.1 Example 001103/16 H /AM = SMBB1 / 0215 0011 / 12AC 1100 19 MN 00 EVT=21 :REQUEST FOR POSIT. STT.=BLOS AF=COMB1+URMB1+HDB1 0316 1900 0421 0130 0240 0CF8 0000 0000 0000 0000 0210 0000 0000 0101 2004 2002 0010 0001 2004 20

2.3.2 Coding of the additional information / 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 tyac : 16 Type of action 0 Read state 1 Position to blocked 2 Position to in service 3 Position to unavailable 4 Position to system unavailable 5 Position to test 6 Position reconfigurable MLs to in service

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 posp : 4
1AA 00014 0004 (9007) A4 ALICE 04.10

Primary positioning 0 Not equipped 1 In service 2 Manually blocked 3 Unavailable

(NEQ) (ES) (BLOM) (INDL)

ED

04 3BW 60437 AAAA RKAHA 97 21 / 97

CIT

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 ctrr : 8 For read state 00 No resource check 10 Resource check For positioning to blocked 00 Insertion on ring A and B 04 Insertion on ring B only 08 Insertion on ring A only For positioning to test 00 Normal (duplex ETUs are not tested) 02 Normal, factory mode 04 Complete (duplex ETUs are tested) 06 Complete, factory mode / 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 tych : 16 Loading type 0 Counterpart 1 OM 2 Change of release 3 No loading 4 Catalog reconfiguration

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 vrsy : 16 System data version 0001 Reference 0065 Working

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 apso : 16 Physical address of loading source

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 asso : 16 System address of loading source (see Appendix A.1 page 67)

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 nofb : 16 Number of BOOT file to be loaded

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 etas : 4 iac : 4 nivs : 8 System state Progress indicator, general initialization System operation level

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20
1AA 00014 0004 (9007) A4 ALICE 04.10

apho : 16

Counterpart physical address

ED

04 3BW 60437 AAAA RKAHA 97 22 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 12AC 1100 0210 0000 0000 0101 2004 2002 0010 0001 2004 20 asho : 16
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

Counterpart system address (see Appendix A.1 page 67)

2.4 CODM=AE11 (FPOS)


Message sent by a station at the end of execution of a blocked, in service or unavailable positioning request. This message exists in two forms depending on whether it conveys the states of eight MLs or more. 2.4.1 Example a) Standard format 001025/11 H /AM = SMBA1 / 0208 0010 / 16AE 1100 / 0000 0000 b) 52 MN 19 EVT=08 :INIT SAMPLE:FPOS KO STT.=INIT AF=COMURMHDA1+PUPE1+TRTXMQGXMRCCGS1+PCA 2511 5219 0420 1004 0000 0000 0000 0000 0000 0000 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03

Format for more than 8 MLs 001030/11 H /AM = SMBA1 / 0208 0010 / 16AE 1100 / 0000 0000 / 0001 2000 / 0001 0100 / 0000 0000 44 MN 55 EVT=08 :INIT SAMPLE:FPOS KO STT.=INIT AF=COMURMHDA1+PUPE1+TRTXMQGXMRCCGS1+PCA 3011 4455 0420 1004 0000 0000 0000 0000 0000 0000 0110 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 8204 2000 0004 C204 2016 0002 0000 000C D800 0001 5200 0001 0200 0001 0300 0001 7C00 0001 0400 0002 A800 0002 C800 0001 5000 0000 0000 0000 0000 00

2.4.2 Coding of the additional information a) Standard format / 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 crdp : 16 Report 0 Successful 1 Failed

/ 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 tyfm : 4
1AA 00014 0004 (9007) A4 ALICE 04.10

Message format 0 Standard

/ 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 tabet(0:7) State of MLs 1 to 8

ED

04 3BW 60437 AAAA RKAHA 97 23 / 97

CIT

.asml : 16 .posp : 4 .etac : 4 .sec : 8

ML system address Primary positioning Current state, for an ML SM Standby indicator, for an application ML
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 caus : 16 Cause of positioning failure

/ 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 asmc : 16 Address of the ML causing the failure

/ 16AE 1100 0104 2016 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0404 2013 0004 03 pare(0:1) : 16 Failure parameters

b)

Format for more than eight MLs / / / / / 16AE 0000 0001 0001 0000 1100 0000 2000 0100 0000 0110 0000 0002 0001 0000 0000 0000 0000 7C00 0000 0000 0000 000C 0001 0000 0000 0000 D800 0400 0000 0000 0000 0001 0002 00 0000 8204 5200 A800 0000 2000 0001 0002 0000 0004 0200 C800 0000 C204 0001 0001 0000 2016 0300 5000

crdp : 16

Report 0 Successful 1 Failed 1100 0000 2000 0100 0000 0110 0000 0002 0001 0000 0000 0000 0000 7C00 0000 0000 0000 000C 0001 0000 0000 0000 D800 0400 0000 0000 0000 0001 0002 00 0000 8204 5200 A800 0000 2000 0001 0002 0000 0004 0200 C800 0000 C204 0001 0001 0000 2016 0300 5000

/ / / / /

16AE 0000 0001 0001 0000

tyfm : 4

Message format 1 More than eight MLs 1100 0000 2000 0100 0000 0110 0000 0002 0001 0000 0000 0000 0000 7C00 0000 0000 0000 000C 0001 0000 0000 0000 D800 0400 0000 0000 0000 0001 0002 00 0000 8204 5200 A800 0000 2000 0001 0002 0000 0004 0200 C800 0000 C204 0001 0001 0000 2016 0300 5000

/ / / / /

16AE 0000 0001 0001 0000

caus : 16
1AA 00014 0004 (9007) A4 ALICE 04.10

Cause of positioning failure

ED

04 3BW 60437 AAAA RKAHA 97 24 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ / / / /

16AE 0000 0001 0001 0000

1100 0000 2000 0100 0000

0110 0000 0002 0001 0000

0000 0000 0000 7C00 0000

0000 0000 000C 0001 0000

0000 0000 D800 0400 0000

0000 0000 0001 0002 00

0000 8204 5200 A800

0000 2000 0001 0002

0000 0004 0200 C800

0000 C204 0001 0001

0000 2016 0300 5000

asmc : 16 / / / / / 16AE 0000 0001 0001 0000

Address of ML causing the failure 1100 0000 2000 0100 0000 0110 0000 0002 0001 0000 0000 0000 0000 7C00 0000 0000 0000 000C 0001 0000 0000 0000 D800 0400 0000 0000 0000 0001 0002 00 0000 8204 5200 A800 0000 2000 0001 0002 0000 0004 0200 C800 0000 C204 0001 0001 0000 2016 0300 5000

pare(0:1) : 16 Failure parameter / / / / / 16AE 0000 0001 0001 0000 1100 0000 2000 0100 0000 0110 0000 0002 0001 0000 0000 0000 0000 7C00 0000 0000 0000 000C 0001 0000 0000 0000 D800 0400 0000 0000 0000 0001 0002 00 0000 8204 5200 A800 0000 2000 0001 0002 0000 0004 0200 C800 0000 C204 0001 0001 0000 2016 0300 5000

tmlse(0:15) .asml : 16 .posp : 4 .etac : 4 .sec : 8

State of MLs 1 to 16 ML system address Primary positioning Current state for an ML SM Standby indicator for an application ML

Appendix B page 68 can be used to interpret the caus and pare fields; before referring to that appendix, use asmc to determine the type of ML causing the failure.

2.5 CODM=AE91 (FTEST)


The FTEST message is sent when a LOCAVAR routine has finished. 2.5.1 Example 010313/11 H 47 MN 09 EVT=13 :END OF LOCAVAR (MMC) /AM = SMBB2 STT.=TEST AF=COMB2+URMB3+HDB2 / 020D 0103 1311 4709 0423 0131 0242 0CF9 0000 0000 / 27AE 9101 0106 0000 0000 0000 0000 0000 0000 0000 / 2400 5300 0000 0000 01FE FEB0 0880 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000

0000 0000 0000 0000

0000 0003 0000 0000

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 25 / 97

CIT

2.5.2 Coding of the additional information / / / / 27AE 2400 0000 0000 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

pdia : 8

Diagnostic message present (see Appendix C.1 page 89) 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

/ / / /

27AE 2400 0000 0000

nbcac : 8 / / / / 27AE 2400 0000 0000

Number of boards penalty posted 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

rgca(0:7) : 8 / / / / nglr .itype : 2 27AE 2400 0000 0000

List of boards penalty posted (rgca) 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

Group of LRs penalty posted (MCX network) Type of LR group penalty posted 0 GLR SMX Network branch 0 No GLR penalty posted 1 GLR branch A 2 GLR branch B Number of LR group Group of LR penalty posted (RCH network) Type of LR group penalty posted 1 GLR RCH Network branch 0 No GLR penalty posted 1 GLR branch A 2 GLR branch B Number of LR group 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

.nbra : 6

.nglr : 8 nglr .itype : 2

.nbrah : 2

.nglrh : 12
1AA 00014 0004 (9007) A4 ALICE 04.10

/ / / /

27AE 2400 0000 0000

ED

04 3BW 60437 AAAA RKAHA 97 26 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

elac : 8 / / / / 27AE 2400 0000 0000

Element penalty posted 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

lgid : 8 / / / / 27AE 2400 0000 0000

Length of additional information 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

idia(0:35) : 8

Additional information

Non HC technology .nstr : 4 .nbstr : 4 .ntst : 7 *:1 .icmat : 8 .nseq : 8 .iddi(0:7) :32 SMB .ntst : 16 .icmat : 8 .nseq : 8 .iddi(0:7) :32 / / / / 27AE 2400 0000 0000 Test number icmat register Sequence number Diagnostic message identification 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Strategy number Number of strategies Test number Not used icmat register Sequence number Diagnostic message identification

9101 5300 0000 0000

nbcae : 8 / / / / 27AE 2400 0000 0000

Numbers of external boards penalty posted 9101 5300 0000 0000 0106 0000 0000 0000 0000 0000 0000 0000 0000 0003 0000 0000 01FE FEB0 0880 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

idcae(0:3)
1AA 00014 0004 (9007) A4 ALICE 04.10

Identification of external boards apsm of supporting station

.apsm : 16

ED

04 3BW 60437 AAAA RKAHA 97 27 / 97

CIT

.sfca : 8 .rgsf : 8

sfca of external board rgsf of external board


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.6 CODM=AF10 (OTOPH)


The message indicates a central defense timeout. The timer that has timed out is associated with the event it caused. A central defense timer is associated with: monitoring of an action (initialization, LOCAVAR, positioning, etc), periodic functions (standby station locavar, total failure supervision, etc), execution of the general procedure (general initialization, general restart, broadcast, etc).

2.6.1 Example 001027/10 H 53 MN 06 EVT=09 :POS. SAMPLE (FPOS KO) /AM = SMB3 STT.=INDO AF=PUPE3 / 0209 0010 2710 5306 0482 0154 0000 0000 0000 0000 0000 0000 / 13AF 10 001031/11 H 02 MN 00 EVT=08 :INIT SAMPLE:FPOS KO /AM = SMB1 STT.=ES AF=TR1+MQ1+GX1+PCA+MR1+CC1+GS1+TX1+PUPE1 / 0208 0010 3111 0200 0480 1002 0000 0000 0000 0000 0000 0000 / 11AF 10 030313/05 H 38 MN 25 EVT=17 :ACTIVATION REINIT. /AM = SMMB STT.=ES AF=OCB / 0211 0303 1305 3825 0303 017F 0000 0000 0000 0000 0000 0000 / 11AF 10FF FF 2.6.2 Coding of the additional information / 0211 0303 1305 3825 0303 017F 0000 0000 0000 0000 0000 0000 / 11AF 10FF FF info1 : 16 Cause of general initialization FFFF GLR 0 and 1 on branch A and B 0000 ML ETA1 and ETA2 autres type of ml

2.7 CODM=AF16 (OGADI)


This message tells central defense that the ring manager has located a fault on a stations adapter. This message is a request to take the adapter out of service (soft) following a ring test.
1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 28 / 97

CIT

2.7.1 Example 001109/14 H /AM = SMBA2 / 0200 0011 / 11AF 160A 30 MN 12 EVT=00 :SET TO OOS (FAULT) STT.=ES AF=COMA2+URMA3+HDA2 0914 3012 0422 0121 0202 0CD9 0000 0000 0000 0000 8200 2100 00

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.7.2 Coding of the additional information / 11AF 160A 8204 2200 2100 00 amring : 16 Ring AS (see Appendix A.1 page 67)

/ 11AF 160A 8204 2200 2100 00 assm : 16 Station AS (see Appendix A.1 page 67)

/ 11AF 160A 8204 2200 2100 00 sfad : 16 Functional specification of the board supporting the adapter

/ 11AF 160A 8204 2200 2100 00 rgad : 16 Number of the board supporting the adapter

2.7.3 Translation of sfadrgad on a board sfad rgad NON HC sfca 0003 0021 0004 0022 0004 0022 0004 0022 0004 0022 0000 0000 0000 0000 0001 0001 0002 0002 0003 0003 CMPA CMPB CMSA CMSB CMSA CMSB CMSA CMSB CMSA CMSB rgsf 0 0 0 0 1 1 2 2 3 3 sfca CMPHA CMPHB SCH rgsf 0 0 sfca CAGTR CAGTR CAGTR CAGTR CAGTR CAGTR CAGTR CAGTR SMB rgsf 0 0 2 2 1 1 3 3

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 29 / 97

CIT

2.8 CODM=AF20 (OINET)


This message tells central defense that the ML OC has detected a discrepancy between the station state given in the FTET file and the internal state read in the station by the DPOS read message. This message is a request to take the station out of service. 2.8.1 Example a) Standard format

001120/16 H 31 MN 31 EVT=00 :SET TO OOS (FAULT) /AM = SMA2 STT.=ES AF=ETA2 / 0200 0011 2016 3131 0361 0181 0000 0000 0000 0000 0000 0000 / 11AF 2003 6103 6111 0001 8101 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 00

b)

Format for more than eight MLs

001120/16 H 37 MN 04 EVT=00 :SET TO OOS (FAULT) /AM = SMBB1 STT.=ES AF=COMURMHDB1+PUPE2+TRTXMQGXMRCCGS2+PCB / 0200 0011 2016 3704 0421 1005 0000 0000 0000 0000 0000 0000 / 11AF 2010 0004 2111 0001 3001 0002 4001 800C F801 8001 5301 / 8001 0A01 0001 0B01 0001 0901 0001 7D01 0001 0C01 0002 A901 / 0002 C901 0001 5101 8000 0000 0000 0000 0000 0000 00 2.8.2 Coding of the additional information a) Standard format / 11AF 2003 6103 6111 0001 8101 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 00 tyfm : 4 Message format 0 Standard

/ 11AF 2003 6103 6111 0001 8101 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 00 tabet(0:7) .asml : 16 .posp : 4 .etac : 4 .sec : 8 State of MLs 1 to 8 (read in the station) ML system address Primary positioning Current state for an ML SM Standby indicator for an application ML

b)
1AA 00014 0004 (9007) A4 ALICE 04.10

Format for more than eight MLs

ED

04 3BW 60437 AAAA RKAHA 97 30 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 11AF 2010 0004 2111 0001 3001 0002 4001 800C F801 8001 5301 / 8001 0A01 0001 0B01 0001 0901 0001 7D01 0001 0C01 0002 A901 / 0002 C901 0001 5101 8000 0000 0000 0000 0000 0000 00
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

tyfm : 4

Message format 1 More than eight MLs

/ 11AF 2010 0004 2111 0001 3001 0002 4001 800C F801 8001 5301 / 8001 0A01 0001 0B01 0001 0901 0001 7D01 0001 0C01 0002 A901 / 0002 C901 0001 5101 8000 0000 0000 0000 0000 0000 00 tmlse(0:15) .asml : 16 .posp : 4 .etac : 4 .sec : 8 State of MLs 1 to 16 (read in the station) ML system address Primary positioning Current state for an ML SM Standby indicator for an application ML

2.9 CODM=AF23 (ODICH)


This message indicates a change of a stations loading state. The ODICH and OTECH messages are numbered when they pass through the SMMs MIS coupler but are not all registered. Consequently, only the start of an overload can normally be determined. When analyzing the message, the number of each message must be taken into account. The OTECH messages give additional information on the source of the overload. 2.9.1 Example a) Standard format

001122/11 H 19 MN 20 EVT=26 :LOAD MODIFICATION /AM = SMC2 STT.=ES AF=TR2+MQ2+GX2+PCB / 021A 0011 2211 1920 0305 010A 0109 017D 0151 0000 0000 0000 / 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94 b) Format for more than eight MLs

001005/12 H 27 MN 38 EVT=26 :LOAD MODIFICATION /AM = SMC1 STT.=ES AF=TR1+MQ1+GX1+PCA+MR1+CC1+GS1+TX1 / 021A 0010 0512 2738 0304 1000 0000 0000 0000 0000 0000 / 11AF 2303 0410 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0003 0400 0001 / 0001 0100 0001 7C00 0001 5000 0001 0400 0002 A803 0302 / 0001 0300 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 10
1AA 00014 0004 (9007) A4 ALICE 04.10

0000 0000 0200 C800 0000

2.9.2 Coding of the additional information a) Standard format

ED

04 3BW 60437 AAAA RKAHA 97 31 / 97

CIT

/ 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

assm : 8

Stations system address

/ 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94 tyfm : 4 Message format 0 Standard

/ 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94 chml(0:7) .asml : 16 .etch : 8 Load state of MLs 1 to 8 ML system address Load state (see section 2.9.3 page 34) 03 0500 00 03 0500 00

/ 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94 rafr : 8 Refresh indicator 00 Change of state Other Refresh

/ 11AF 2303 0503 0500 0001 0A00 0001 0900 0001 7D00 0001 5101 / 0200 0000 0000 0000 0000 0000 0000 0000 0000 94 nmes : 16 Message number (circular)

b)

Format for more than eight MLs / / / / / 11AF 0000 0001 0001 0000 2303 0000 0100 0300 0000 0410 0000 0001 0000 0000 0000 0000 7C00 0000 0000 0000 0000 0001 0000 0000 0000 0000 5000 0000 10 0000 0000 0001 0000 0000 0000 0400 0000 0000 0003 0002 0000 0000 0400 A803 0000 0000 0001 0302 0000 0000 0200 C800 0000

assm : 16 / / / / / tyfm : 4 11AF 0000 0001 0001 0000

Stations system address 2303 0000 0100 0300 0000 0410 0000 0001 0000 0000 0000 0000 7C00 0000 0000 0000 0000 0001 0000 0000 0000 0000 5000 0000 10 0000 0000 0001 0000 0000 0000 0400 0000 0000 0003 0002 0000 0000 0400 A803 0000 0000 0001 0302 0000 0000 0200 C800 0000

Message format 1 More than eight MLs

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 32 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ / / / / rafr : 8

11AF 0000 0001 0001 0000

2303 0000 0100 0300 0000

0410 0000 0001 0000 0000

0000 0000 7C00 0000 0000

0000 0000 0001 0000 0000

0000 0000 5000 0000 10

0000 0000 0001 0000

0000 0000 0400 0000

0000 0003 0002 0000

0000 0400 A803 0000

0000 0001 0302 0000

0000 0200 C800 0000

Refresh indicator 00 Change of state Other Refresh 11AF 0000 0001 0001 0000 2303 0000 0100 0300 0000 0410 0000 0001 0000 0000 0000 0000 7C00 0000 0000 0000 0000 0001 0000 0000 0000 0000 5000 0000 10 0000 0000 0001 0000 0000 0000 0400 0000 0000 0003 0002 0000 0000 0400 A803 0000 0000 0001 0302 0000 0000 0200 C800 0000

/ / / / /

chml(0:15) .asml : 16 .etch : 8

Load state of MLs 1 to 15 ML system address Load state (see section 2.9.3 page 34) 2303 0000 0100 0300 0000 0410 0000 0001 0000 0000 0000 0000 7C00 0000 0000 0000 0000 0001 0000 0000 0000 0000 5000 0000 10 0000 0000 0001 0000 0000 0000 0400 0000 03 0400 00 03 0400 00

/ / / / /

11AF 0000 0001 0001 0000

0000 0003 0002 0000

0000 0400 A803 0000

0000 0001 0302 0000

0000 0200 C800 0000

nmes : 16

Message number (circular)

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 33 / 97

CIT

2.9.3 Load state etch 00 01 call types rejected No rejection originating calls from mobile subscriber terminating calls to mobile subscriber IN access originating calls from fixed subscriber non urgent and non LSS originating calls from fixed subscriber non LSS, originating calls from mobile subscriber originating calls from fixed subscriber, non LSS originating calls from mobile subscriber No 7 terminating calls, non priority and non CP originating calls from fixed subscriber, non LSS originating calls from mobile subscriber No 7 terminating calls, non priority and non CP channel associated terminating calls, non CP originating calls from fixed subscriber, non LSS originating calls from mobile subscriber No 7 terminating calls, non CP channel associated terminating calls, non CP originating calls from fixed subscriber, non LSS for CSN or AN originating calls from mobile subscriber No 7 terminating calls channel associated terminating calls originating calls from fixed subscriber originating calls from mobile subscriber No 7 terminating calls channel associated terminating calls type of detection Normal load Server resources
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

02 03 04

Site dimensioning resources (threshold 1 traffic) Site dimensioning resources (threshold 2 traffic, RF) ML CC resources

05

Site dimensioning resources (threshold 3 traffic, RF, AN channels)

06

Processor load

07

Queue load

0F

DHA server unavailable

2.10 CODM=AF30 (OINCI)


This message is from the LCC or MLOC. It identifies the active SMM. 2.10.1 Example 001121/20 H 04 MN 26 EVT=18 :SMM SWITCHOVER /AM = SMMA STT.=ES AF=OCA / 0212 0011 2120 0426 0302 017E 0000 0000 0000 0000 0000 0000 / 11AF 3001 0F00 00

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 34 / 97

CIT

2.10.2 Coding of the additional information / 11AF 3001 0F00 00


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

asor : 16

System address of sender (OM or MLOC) OM origin (LCC on absence of messages from coupler) This is usually a selfpositioning of the active SMMs MIS coupler. MLOC origin (routine station state check) This is usually a fault in the active SMM coupler or a cascade of station selfpositionings.

/ 11AF 3001 0F00 00 causi : 16 Switchover cause (for MLOC origin) 0001 State inconsistency threshold violation 0002 No reply on MIS threshold violation 0003 No reply on MAS threshold violation

2.11 CODM=AF40 (ORIPO)


This message is a take out of service request due to: Penalty posting by the anomaly statistics process Penalty posting by an application ML Inaccessibility of a station The station is no longer responding to the routine read status message (selfpositioning not indicated, power supply outage).

2.11.1 Example a) Penalty posting by the anomaly statistics process

001218/16 H 23 MN 32 EVT=00 :SET TO OOS (FAULT) /AM = SMB4 STT.=ES AF=TR1+MQ1+GX1+PCA / 0200 0012 1816 2332 0483 0102 0101 017C 0150 0000 0000 0000 / 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 b) Penalty posting by an application ML

001207/16 H 25 MN 02 EVT=00 :SET TO OOS (FAULT) /AM = SMB11 STT.=ES AF=PUPE3 / 0200 0012 0716 2502 048A 0154 0000 0000 0000 0000 0000 0000 / 11AF 4000 0001 5401 50 c)
1AA 00014 0004 (9007) A4 ALICE 04.10

Inaccessibility of a station

001027/17 H 51 MN 19 EVT=00 :SET TO OOS (FAULT) /AM = SMA1 STT.=ES AF=ETA1 / 0200 0010 2717 5119 0360 0180 0000 0000 0000 0000 0000 0000 / 11AF 4000 0103 6001 7F

ED

04 3BW 60437 AAAA RKAHA 97 35 / 97

CIT

2.11.2 Coding of the additional information a) Penalty posting by the anomaly statistics process / 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 typa : 16 Type of penalty posting 0000 Statistics indication
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 asml : 16 Penalty posted system address

/ 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 asem : 16 System address of the sender of the anomaly

/ 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 .info(0:8) : 16 Word 0 to 8 of the anomaly / 11AF 4000 0004 8304 8500 0100 0501 8300 0001 D500 0004 8300 / 0000 0F0D C3 .ft : 8 Function and type of the anomaly message (see Appendix D page 92)

b)

Penalty posting by an application ML / 11AF 4000 0001 5401 50

typa : 16

Type of penalty posting 0000 Statistical posting

/ 11AF 4000 0001 5401 50 asml : 16 Penalty posted system address

/ 11AF 4000 0001 5401 50 asem : 16 System address of the sender of the penalty posting PC Ratio of channels HS per MSU exceeded HD No response to update request DMJDO GETU IAILA fault

c)

Station inaccessibility / 11AF 4000 0103 6001 7F

1AA 00014 0004 (9007) A4 ALICE 04.10

typa : 16

Type of penalty posting 0001 Inaccessible

ED

04 3BW 60437 AAAA RKAHA 97 36 / 97

CIT

/ 11AF 4000 0103 6001 7F asml : 16


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

System address of the station

/ 11AF 4000 0103 6001 7F asem : 16 System address of the sender of the accusation 017E017F MLOC, no answer to the routine read status message 030204FF System address of the station that has detected the inaccessibility (station inaccessible by one multiplex OINAS)

2.12 CODM=AF41 (OSETA)


This message is sent by a station to indicate a change of ML state. 2.12.1 Example a) Standard format

001207/02 H 20 MN 06 EVT=25 :ML SWITCHOVER /AM = SMBB1 STT.=ES AF=COMB1+URMB1+HDB1 / 0219 0012 0702 2006 0421 0130 0240 0CF8 0000 0000 0000 0000 / 11AF 4104 2104 2111 0001 3001 0002 4001 000C F801 0000 0010 / 0000 0010 0000 0010 0000 0010 00 b) Format for more than eight MLs

001129/04 H 47 MN 04 EVT=02 :START INITIALIZAT. /AM = SMB2 STT.=BLOS AF=TR2+MQ2+GX2+PCB+MR2+CC2+GS2+TX2+PUPE2 / 0202 0011 2904 4704 0481 1003 0000 0000 0000 0000 0000 0000 / 12AF 411F FF04 8011 0001 0201 0001 0101 0001 7C01 0001 5005 / 0001 0405 0002 A805 0002 C805 0001 0301 0001 5206 0000 0021 / 0000 0021 0000 0021 0000 0021 0000 0021 0000 0021 00 2.12.2 Coding of the additional information a) Standard format / 11AF 4104 2104 2111 0001 3001 0002 4001 000C F801 0000 0010 / 0000 0010 0000 0010 0000 0010 00 tyfm : 4 Message format 0 Standard

/ 11AF 4104 2104 2111 0001 3001 0002 4001 000C F801 0000 0010 / 0000 0010 0000 0010 0000 0010 00 tabet(0:7)
1AA 00014 0004 (9007) A4 ALICE 04.10

State of MLs 1 to 8 ML system address Primary positioning

.asml : 16 .posp : 4

ED

04 3BW 60437 AAAA RKAHA 97 37 / 97

CIT

.etac : 4 .sec : 8

Current state for an ML SM Standby indicator for an application ML


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

b)

Format for more than eight MLs / 12AF 411F FF04 8011 0001 0201 0001 0101 0001 7C01 0001 5005 / 0001 0405 0002 A805 0002 C805 0001 0301 0001 5206 0000 0021 / 0000 0021 0000 0021 0000 0021 0000 0021 0000 0021 00

tyfm : 4

Message format 1 More than eight MLs

/ 12AF 411F FF04 8011 0001 0201 0001 0101 0001 7C01 0001 5005 / 0001 0405 0002 A805 0002 C805 0001 0301 0001 5206 0000 0021 / 0000 0021 0000 0021 0000 0021 0000 0021 0000 0021 00 tmlse(0:15) .asml : 16 .posp : 4 .etac : 4 .sec : 8 State of MLs 1 to 16 ML system address Primary positioning Current state, for an ML SM Standby indicator for an application ML

2.13 CODM=AF44 (OSETE)


This message is sent by a gateway station. It indicates the change of state of an external server instance. 2.13.1 Example 001030/16 H 35 MN / 021F 0010 3016 / 10AF 440A FE9C / 0000 0000 0000 47 EVT=31 3547 0000 4800 0000 0000 0000 :SER. EXT. STT. MOD 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 00

2.13.2 Coding of the additional information / 10AF 440A FE9C 4800 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 00 tmlse(0:3) .asmle : 16 State of 1 to 4 instances Instance system address 0A FE9C 4800 0000 00

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 38 / 97

CIT

.port : 16

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

Port number 0014 FTP 0015 FTP 2B03 CDRA 9C48 TRSV 9C4E SU2A01, SU2A02, UMTS 9C4D DMODI System state (not used) Current state 0 Not in service 1 In service 4 Unavailable Substate TRSV 1 Nominal 2 Read 4 Degradated Progress indicator (not used)

0A FE9C 4800 0000 00

.etas : 4 .etace:4

0A FE9C 4800 0000 00 0A FE9C 4800 0000 00

.setat:4

0A FE9C 4800 0000 00

.iac:4

0A FE9C 4800 0000 00

2.14 CODM=AF61 (ORPOS)


This message is sent by the ML SM to central defense to indicate a serious or soft fault in the station. For a serious fault, the station returns to prom. This is a selfpositioning. For a soft fault, central defense stops the station by positioning it to INDL and then BLO. Message AF61 originates from a hardware fault, software fault or an event outside the station. To determine the origin of the station shutdown: analyze the result of the LOCAVAR tests, correlate the shutdown with an external event (converters, multiplex, network fault), collect the information if it is a software fault (use the DPMIL command; on SMB, the SITSFG area (FZDEF file of ZSM) of the dump gives the context of the shutdown).

2.14.1 Example 001027/13 H /AM = SMBA1 / 0200 0010 / 11AF 6100 / 0500 BC 59 MN 20 EVT=00 :SET TO OOS (FAULT) STT.=ES AF=COMURMHDA1+PUPE1+TRTXMQGXMRCCGS1+PCA 2713 5920 0420 1004 0000 0000 0000 0000 0000 0000 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749

1AA 00014 0004 (9007) A4 ALICE 04.10

001027/13 H 59 MN 30 EVT=00 :SET TO OOS (FAULT) /AM = SMA1 STT.=ES AF=ETA1 / 0200 0010 2713 5930 0360 0180 0000 0000 0000 0000 0000 0000 / 11AF 6100 0000 0000 0000 0180 004A 0E08 0100 4000 0000 0000 / 0000 00

ED

04 3BW 60437 AAAA RKAHA 97 39 / 97

CIT

2.14.2 Coding of the additional information / 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC tyre : 16 Type of request 0000 Serious fault 0001 Adapter failure 0002 Noncompelled fault 0003 Permanent abnormal overload 0004 Serious software fault (no locavar) 0006 Soft software fault (no locavar)

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC rgca : 8 rgca of the faulty board or applique

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC icmat : 8 Hardware fault register If icmat is not 00, it is a hardware fault (see 2.14.2.2 and 2.14.2.3)

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC iclog : 8 Software fault register If iclog is not 00, it is a software fault transmitted by the SFG mechanism (communication with the CMP was not possible) On SMB, the software fault register has 16 bits and the iclog field contains the registers eight high order bits

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC idmu : 8 Multiplex identification (form=02) 00 MISA 01 MAS1 02 MAS2 03 MAS3 04 MAS4

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC idad : 8 Adapter identification (form=02) even Adapter A odd Adapter B

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC
1AA 00014 0004 (9007) A4 ALICE 04.10

asml : 16

System address of the active component at the time of the fault (not necessarily the origin of the fault)

ED

04 3BW 60437 AAAA RKAHA 97 40 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

inf8(0:3) : 8

Additional information (according to form and numano)

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC form : 8 Message format 01 ML fault 02 Adapter failure 03 Minor fault counter overflow 04 Fault transmission from local defense to central defense 05 Hardware fault or bus error

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC numano : 16 Anomaly number

/ 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC diapr : 8 Old technology PROM diagnostic On SMB rgem of the hardware element rgem specifies the faulty element on the board or applique / 11AF 6100 000A 0000 0000 0420 0505 000F 0500 BC00 5346 4749 / 0500 BC infs(0:6) : 8 Additional information (according to numano)

2.14.2.1 Additional information (inf8) 2.14.2.1.1 ML fault (form=01) / 11AF 6100 0000 0000 0000 0181 004A 0E08 0100 4000 0000 0000 / 0000 00 sens3 Subset 3 (according to tyml and numano)

/ 11AF 6100 0000 0000 0000 0181 004A 0E08 0100 4000 0000 0000 / 0000 00 sens2 Subset 2 (according to tyml and numano)

/ 11AF 6100 0000 0000 0000 0181 004A 0E08 0100 4000 0000 0000 / 0000 00 sens1
1AA 00014 0004 (9007) A4 ALICE 04.10

Subset 1 (according to tyml and numano)

ED

04 3BW 60437 AAAA RKAHA 97 41 / 97

CIT

/ 11AF 6100 0000 0000 0000 0181 004A 0E08 0100 4000 0000 0000 / 0000 00
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

tyml

Type of ml

2.14.2.1.2 Adapter fault (form=02) / 34AF 6100 0100 0000 02CC 0362 04CC 0006 0200 5000 0000 0211 / 0000 00 cinc Cause of channel unavailability 04 Adapter failure / 34AF 6100 0100 0000 02CC 0362 04CC 0006 0200 5000 0000 0211 / 0000 00 ran Adapter number even=A, odd=B / 34AF 6100 0100 0000 02CC 0362 04CC 0006 0200 5000 0000 0211 / 0000 00 cmde Command

/ 34AF 6100 0100 0000 02CC 0362 04CC 0006 0200 5000 0000 0211 / 0000 00 caus Cause of failure (see 2.14.2.4 page 45)

2.14.2.1.3 Minor fault counter overflow (form=03) / 11AF 6100 0200 0000 0000 0150 4100 0106 0300 4200 0000 0000 / 0000 00 sens3 Subset 3 (according to tyml and numano) / 11AF 6100 0200 0000 0000 0150 4100 0106 0300 4200 0000 0000 / 0000 00 sens2 Subset 2 (according to tyml and numano) / 11AF 6100 0200 0000 0000 0150 4100 0106 0300 4200 0000 0000 / 0000 00 sad Component subaddress / 11AF 6100 0200 0000 0000 0150 4100 0106 0300 4200 0000 0000 / 0000 00 tyml
1AA 00014 0004 (9007) A4 ALICE 04.10

Type of ml

ED

04 3BW 60437 AAAA RKAHA 97 42 / 97

CIT

2.14.2.1.4 Local defense to central defense transmission fault (form=04) / 11AF 6100 0000 0000 0000 0150 0000 FFFE 0400 4200 0000 0000 / 0000 00 crt Transmission failure report

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.14.2.1.5 Hardware fault or bus error on main coupler (form=05, numano=00BC) / 11AF 6100 000A 0000 0000 048A 0505 000F 0500 BC00 5346 4749 / 0500 BC vect Interrupt vector (see 2.14.2.5 page 46) / 11AF 6100 000A 0000 0000 048A 0505 000F 0500 BC00 5346 4749 / 0500 BC sad Component subaddress / 11AF 6100 000A 0000 0000 048A 0505 000F 0500 BC00 5346 4749 / 0500 BC tyml Type of ml / 11AF 6100 000A 0000 0000 048A 0505 000F 0500 BC00 5346 4749 / 0500 BC exlo If SMB, Logic exception in ASCII (SMB) SFGI Undefined serious fault SFGD Remote serious fault SFGL Local serious fault MEMO Memory fault (ECC) Else, Programm Counter

5346 5346 5346 4D45

4749 4744 474C 4D4F

pc

2.14.2.1.6 Hardware fault or bus error in prom or boot (form=05, numano=00FE) / 15AF 6100 0004 0800 0000 0305 0025 0840 0500 FE00 0000 0000 / 0000 00 pc Program counter

2.14.2.1.7 Hardware fault or bus error on secondary agent (form=05, numano=00FF) / 15AF 6100 0004 0800 0000 0420 0000 0000 0500 FF02 5346 4744 / 0500 FF icloge Extended software fault register (SMB) 0000 Not significant Type of fault (0=serious, 1=minor) Type of ml Anomaly number

1AA 00014 0004 (9007) A4 ALICE 04.10

.typf : 1 .tyml : 5 .nano :10

ED

04 3BW 60437 AAAA RKAHA 97 43 / 97

CIT

/ 15AF 6100 0004 0800 0000 0420 0000 0000 0500 FF02 5346 4744 / 0500 FF
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

exlo

Logical exception in ASCII (SMB)

2.14.2.2 Old technology ICMAT 80 LMER ADB 40 LBE ADA 20 10 08 04 02 01 DBE WDP WDCY RBE XMER XBE Memory error on local bus access (ACUTR) Memory access by adapter B (ACAJ) Program watchdog Memory access by adapter A (ACAJ) Bus error on illegal DMA access (ACAJ) Program watchdog Bus error on triggering of watchdog cycle Bus error on parity fault in private memory Memory error from BSM (XBE is always accompanied by XMER) Bus error from BSM

2.14.2.3 SMB ICMAT 80 ACPWU ACMPR ACAUX 40 ACPWU ACMPR AAETH ACAUX AATAD 20 ACPWU ACMPR ACAUX 10
1AA 00014 0004 (9007) A4 ALICE 04.10

Hardware watchdog Hardware watchdog Fault from module 2 (FMOD2) Double machine check Double machine check POSFGD fault for defense self test POSFGD signal fault ICMAT fault simulation by positioning Serious fault detected by AGMMB Defined serious fault, ADSMO module C (AGMPA, PQUICC) ACAUX Fault from module 1 (FMOD1)

ACPWU ACMPR AAETH ACAUX

Serious fault detected by AGQBI Defined serious fault, ADSMO module B (AGMPA, PQUICC) Parity fault detected by the PQUICC Fault from module 0 (FMOD0)

ED

04 3BW 60437 AAAA RKAHA 97 44 / 97

CIT

08

ACPWU ACMPR

Serious fault detected by AGSDC Defined serious fault, ADSMO module A (AGMPA, PQUICC) Serious fault on common part (AGTRA internal) Type TEA defined serious fault Type TEA defined serious fault Serious fault detected by AGIOB Defined serious fault, AGLAX, AGSDC or AGIOB Adapter B serious fault Hard reset defined serious fault Hard reset defined serious fault Serious fault detected by AGLAB Defined serious fault, AGQBI, AGLAB or AGMMB Adapter A serious fault Soft reset defined serious fault Soft reset defined serious fault Power supply fault

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

AATRA AAETH ACAUX 04 ACPWU ACMPR AATRA AAETH ACAUX 02 ACPWU ACMPR AATRA AAETH ACAUX 01

2.14.2.4 Cause of adapter failure caus 01 02 meaning Ring status IT Command rejected additional information infs(01) Status infs(01) Status nfs(23) Ring number

03 04

Command timeout Check IT infs(01) Adapter check status infs(23) Current command infs(01) Status infs(01) Status infs(25) Next RL address infs(2) infs(3) Open status Open error code

05

SSB error on receive IT

06

Open command failure

07
1AA 00014 0004 (9007) A4 ALICE 04.10

SSB incorrect on transmit IT

infs(01) Status infs(23) Cstat of the TL

ED

04 3BW 60437 AAAA RKAHA 97 45 / 97

CIT

08

Unknown command acknowledge

infs(01) Status infs(23) Status continued


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

09

Transmit stop without switchover requested

infs(01) Status infs(23) Cstat of the TL

2.14.2.5 Exception vectors 68K 0208 030C 0410 0514 0820 1438 0501 0502 0503 0505 0507 0508 0509 0510 0511 0513 0514 0200 0300 0300 0400 0600 0700 0800 0D00 1300 1400 1700 Bus error Address error Illegal instruction Division by 0 Privilege violation Format error SFGL MMB SFGI LAB SFGD OUT SFGI OUT Watchdog FEVT SDC FEVT IOB FEVT MMB SFGI LAB SFGI QBI FEVT LAX Machine check or memory fault EMMU instruction Traces EMMU data Program alignment Program (illegal instruction, division by 0) Floating point Traces Traces System management Thermal management

PPC

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 46 / 97

CIT

PQUICC

0100 0101 0210 0211 0300 0400 0510 0520 0551 0568 0569 0570 0600 0700 0D00 1000 1C00 1D00

Watchdog External reset Machine check Memory fault MMU data EMMU instruction SFGI LAB FEVT LAB SFGL ethernet 100 M LETH1 fault (change of transceiver state) LETH1 fault (transceiver fault) LETH0 fault (change of transceiver state) Program (alignment) Program (illegal instruction, division by 0) Traces Program (illegal instruction) Traces Traces

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.15 CODM=AF63 (OTECH)


This message is a trace of a change of load state. The ODICH and OTECH messages are numbered when they pass through the SMMs MIS coupler but are not all registered. Consequently, only the start of an overload can normally be determined. When analyzing the message, the number of each message must be taken into account. The OTECH messages give additional information on the origin of the overload. 2.15.1 Example 001122/11 H 19 MN 19 EVT=26 :LOAD MODIFICATION /AM = SMC2 STT.=ES AF=TR2+MQ2+GX2+PCB / 021A 0011 2211 1919 0305 010A 0109 017D 0151 0000 0000 0000 / 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 2.15.2 Coding of the additional information / 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 asml : 8 System address of the overloaded ML TSAP of the overloaded TCA (for ndch ETU) apsm (9), rgtu (7) SMB group (5) rgtu (7) rget (4)

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 ndch : 8 Detection point number (see section 2.15.3 page 48)

1AA 00014 0004 (9007) A4 ALICE 04.10

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 etch : 8 Load state (see section 2.9.3 page 34)

ED

04 3BW 60437 AAAA RKAHA 97 47 / 97

CIT

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 evch : 8 Load event 0 Return to normal load 1 Start of abnormal load

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 infc(0:1) : 32 Additional information

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 asmla : 16 System address of the standalone ML

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 etcha : 8 Resultant load state for the standalone ML (see section 2.9.3 page 34)

/ 11AF 6301 5101 0201 0100 01C9 9C00 242D 0151 02C9 0093 nmes Message number (circular)

2.15.3 Detection point MLs concerned All MLs 00 01 02 02 03 04 02 03 02 03 02 03 04 05 06 07 08 09 0A 0B detection point (ndch) Processor load Standard receive queues AiPj receive queues BLG system contexts BML system contexts Process contexts LVS receive queues ET receive queues PHDLC rate LVS receive queues MQ1 buffer Aux A MQ2 buffer Aux A MQ1 buffer Aux B MQ2 buffer Aux B MQ1 queue Aux A MQ2 queue Aux A MQ1 queue Aux B MQ2 queue Aux B Aux A channel associated activity Aux B channel associated activity

MLSM coupler MLGS, PUPEI, PCI

MLURMS

PHDLC

MLURM1G

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 48 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

MLCC

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

02 03 04 05 06 07 02 04 05 02 03 04 02 02 03 04 01 02 04 05

Global count threshold 1 Global count threshold 2 Global count threshold 3 Operations global count System context pool Process context pool TTM load RF traffic threshold 1 RF traffic threshold 2 Macro > interchange unit queue Number of extensions seized TTM context pool Macro > interchange unit queue Macro > BMR queue BMR system context pool BMR process context pool Message I3 receive queues Ai,Pj MLSMPH queue PHDLC rate PHDLC receive queue (or 08) (or 07) (or 06)

MLMQ

MLTX

MLMRP MLMRS

MLSMPH

ETU

3D TCCX receive queue 3E TCCX load 3F Main TCA load

MLAN

02 MLANL receive queue 03 MLANL rate 04 AN connection channels threshold 1 05 AN connection channels threshold 2 06 AN connection channels threshold 3 0817 lev2 FCTX transmit queues (1 / TH) 1827 lev2 receive buffer pools (1 / TH) 02 03 04 05 06 02 03 04 05 06 07 02 03 04 05 SST receive queue (in ME) SST rate D1/Pj queues D2/Pj queues Extended domains/Pj queues HDLC receive queue Global rate Bus ICL1 rate Bus ICL2 rate Bus ICL3 rate ICL FRHDLC queue Ethernet receive queue Global rate Sending stack Receiving stack

MLSM (SST) on SMB

MLSM (HDLC) on SMB

MLSM (Ethernet) on SMB


1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 49 / 97

CIT

PUPEL

MLGX, MLSM agent, MLCOM MLPUPEN, MLHD

02

Process context pool

2.16 CODM=AF71 (OPOS)


This message indicates the end of execution of a stations return to PROM. The station is accessible. If OPOS is received from a station in service, it means a station shutdown that could not be indicated (ORPOS cannot be transmitted). 2.16.1 Example 001204/17 H /AM = SMBA1 / 0204 0012 / 17AF 7102 20 MN 08 EVT=04 :START AUTOM.LOCAVAR STT.=TEST AF=COMA1+URMA1+HDA1 0417 2008 0420 0120 0200 0CD8 0000 0000 0000 0000 00

2.16.2 Coding of the additional information / 17AF 7102 00 etac : 4 Current state 2 Blocked by system

2.17 CODM=AF73 (OETER)


The OETER message is sent by a station to indicate an event relating to the ETUs. OETER is used to indicate: Taking an ETP out of service on a fault The failure of an ETU (end of LOCAVAR ETP KO) Execution of a positioning by operator command End of initialization of an ETP Switchover to standby ETU Return to normal ETU Failure of switchover to standby ETU

2.17.1 Example
1AA 00014 0004 (9007) A4 ALICE 04.10

a)

Taking an ETU out of service on a fault

ED

04 3BW 60437 AAAA RKAHA 97 50 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

03 04 05 06 07 08 09

Global rate Pquicc1 rate Pquicc2 rate Pquicc3 rate Pquicc1 FREC Pquicc2 FREC Pquicc3 FREC

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

010121/12 H 41 MN 35 EVT=27 :ETP SET OOS (FAULT) /AM = SMBB3 STT.=ES AF=COMB3 / 021B 0101 2112 4135 0425 0132 0000 0000 0000 0000 0000 0000 / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 b) Failure of an ETU (end of LOCAVAR ETP KO) 010121/11 H /AM = SMBA1 / 021C 0101 / 11AF 730C / 8001 B800 c) 48 MN 39 EVT=28 :ETP LOCAVAR END NOK STT.=ES AF=COMA1+URMA33+HDA1 2111 4839 0420 0120 0220 0CD8 0000 0000 0000 0000 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 A001

Positioning by operator command 010122/09 H /AM = SMBA1 / 021D 0101 / 11AF 7300 / 0000 0000 54 MN 28 EVT=29 :ETU POSIT. BY MMC STT.=ES AF=COMA1+URMA33+HDA1 2209 5428 0420 0120 0220 0CD8 0000 0000 0000 0000 2103 11FF 0701 0000 0000 0000 0000 0000 0000 0000 0000

d)

End of initialization of an ETP 010121/11 H /AM = SMBA2 / 021E 0101 / 11AF 7300 / 0000 0000 42 MN 50 EVT=30 :END OF ETP INIT. STT.=ES AF=COMA2+URMA34+HDA2 2111 4250 0422 0121 0221 0CD9 0000 0000 0000 0000 4104 1100 FF00 0000 0000 0000 0000 0000 0000 0000 0000

e)

Switchover to standby ETU 030222/15 H 09 MN 10 EVT=31 :ETU SWITCHOVER OK /AM = SMBA2 STT.=ES AF=COMA2+URMA2+HDA2 / 021F 0302 2215 0910 0422 0121 0201 0CD9 0000 0000 0000 0000 / 11AF 7302 6105 11FF 0012 0901 0000 0000 0000 0000 0000 0000 / 0000 0000 0000

f)

Return to normal ETU 030331/20 H 36 MN 00 EVT=32 :RETURN TO INIT. ETU /AM = SMBA1 STT.=ES AF=COMA1+URMA1+HDA1 / 0220 0303 3120 3600 0420 0120 0200 0CD8 0000 0000 0000 0000 / 11AF 7302 6106 11FF 0012 0603 0000 0000 0000 0000 0000 0000 / 0000 0000 0000

g)

Failure of switchover to standby ETU 021023/14 H /AM = SMBA1 / 0221 0210 / 11AF 7301 / 0000 0000 55 MN 22 EVT=33 :ETU SWITCHOVER FAIL ETAT=ES AF=COMA1+URMA1+HDA1 2314 5522 0420 0120 0200 0CD8 0000 0000 0000 0000 2107 21FF 0308 0701 0000 0000 0000 0000 0000 0000 0000

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 51 / 97

CIT

2.17.2 Coding of the additional information 2.17.2.1 Standard information / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 adetp : 16 Address of the ETP tyro (2 bits) Type of routing rgtu (9 bits) ETU number (1 to 128) rget (5 bits) Number of the first ET of the ETP (1 to 31) 01 61 ETU=11 ET=1
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 cetu : 8 Event number 01 Taking an ETP out of service on fault 02 End of LOCAVAR ETP KO 03 Positioning by operator command 04 End of initialization of an ETP 05 Switchover to standby ETU 06 Return to normal ETU 07 Failure of switchover to standby ETU

/ 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 posptu : 4 Primary positioning of the ETU 0 Not equipped 1 In service 2 Manual blocked 3 Unavailable

/ 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 etatpu : 4 Current state of the ETU 0 Not equipped 1 In service 2 Blocked 3 Unavailable busy 4 Unavailable free 5 Initializing 6 Loading 7 Testing

2.17.2.2 Taking an ETP out of service on fault / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 type Type of event 01 Soft positioning request FF Hard positioning request 04 3BW 60437 AAAA RKAHA 97 52 / 97

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

CIT

/ 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

asml

System address of the ML reporting the penalty posting (See A.1 page 67 and 2.1.5 page 18) / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000

mpcc

Penalty posting message code class AF87 OFETP AF97 OFET

/ 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 inf1 Additional information / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 inf2 Additional information / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 inf3 Additional information / 11AF 7301 6101 1101 FF01 7DAF 9700 46BB 1D13 0000 0000 0000 / 0000 0000 0000 mpccu If the MLSMU is indicated, penalty posting message code class AB18 OACLA LAP fault AB28 ODELA LAP fault AB38 OFOLA LAP fault AF17 ONRTP ETP abort B914 RCHET Loading failure BB10 No ETP response BB20 No ETP response BB30 No ETP response

2.17.2.2.1 MLSMU penalty posting inf1 00pp pp Process number inf2 Service number / service state rtu : ETU slot Slot=20+(rtu*6) ALS range (0, 1) inf3 Message received internal code rtuCause

FF01

RAB bus audit (standby ETU) RAB bus audit (ALS) Time out (GETU) RAB bus audit (GETU)

FF02
1AA 00014 0004 (9007) A4 ALICE 04.10

alsCause

FF03 FF04

OEITPI cause

ED

04 3BW 60437 AAAA RKAHA 97 53 / 97

CIT

FF05

Switchover activation failure (GETU)


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

FF06 FF07

Switchover failure (GETU) Switchover failure (ALS accusation) Switchover failure (standby ETU accusation) Switchover failure (ALS accusation) Switchover failure (standby ETU accusation) Switchover failure (standby ETU accusation) tuCause / rtuCause alsCause[0]

FF08

tuCause / rtuCause

alsCause[0]

FF09

tuCause / rtuCause

alsCause[1]

FF0A

tuCause / rtuCause

alsCause[1]

FF0B

tuCause / rtuCause

2.17.2.2.1.1 tuCause values tuCause 00 01 02 03 04 05 06 07 FF Local TU cause (stand by ETU) Every thing is ok Not significant Applique not present Not a spare ETU Erroneous spare ETU Protection already active Protection not active RAB unavailable Undefined cause

2.17.2.2.1.2 rtuCause values rtuCause Distant TU cause (ETU to back up)

1AA 00014 0004 (9007) A4 ALICE 04.10

00 01 02 03 04 05 06 07 08 09 FF

Every thing is ok Not significant Invalid RTU Applique not present Unknown RTU applique RAB taking unsuccessful Sent cell not received Received cell mismatch LBS do not succeed ACS do not succeed Undefined cause

ED

04 3BW 60437 AAAA RKAHA 97 54 / 97

CIT

2.17.2.2.1.3 alsCause values alsCause


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

ALS TU cause Every thing is ok Not significant Invalid ALS ALS not responding SwStMism LpStMism Sent pattern not received Received pattern mismatch ALS switch fail ALS loop fail Invalid spare TU identification Invalid primary TU identification Invalid kind of LA LA configuration is not valid ALS init is not complete The max number of loops is reached ALS resource error Command has not been refreshed Communication unavailable with ALS Incompatible TU state Undefined cause

00 01 02 03 04 05 06 07 08 09 51 52 53 54 55 56 57 58 59 71 FF

2.17.2.2.2 MLSMP penalty posting inf1 inf2 inf3

This is a penalty posting sent by the ET. The information depends on the type of ETU.

2.17.2.2.3 MLGX penalty posting (simplex ETU) inf3 111B 50 51 52 Process number No TCA response Input FNC fault branch A/B Output FNC fault branch A/B ETU/GLR indication ETU indication GLR indication OFGLR on GLR not equipped OFGLR type invalid TCA penalty posting on IPP fault inf2 Classcodm crt RIPA2 / RCOC2 crt RCOC2 0000 inf1 Anomaly number GLR GLR GLRS

60 61 62
1AA 00014 0004 (9007) A4 ALICE 04.10

FTAC2 access index FTAC2 access index FTAC2 access index Classcodm Classcodm 0000

GLR numbers GLR numbers GLR numbers GLR Fault type 0000

70 71 72

ED

04 3BW 60437 AAAA RKAHA 97 55 / 97

CIT

808F

Penalty posting on port or board fault Penalty posting on AAL fault No response to reconfiguration request from GT to TCAt Restart without loading

bit field indicating faults found

A0

codm RRCG2

class RRCG2

B0

7777

7777

2.17.2.2.4 MLGX penalty posting (duplex (ETU) inf3 Double LA fault GLR number LA state URM group AS inf2 inf1

2.17.2.2.5 MLHD penalty posting inf2 0504 Fault subscription Administrative state configuration Administrative state configuration Read of all faults Read of PM faults Read of LT faults 1 line profile configuration 1 line data write APS configuration APS positioning APS read Path fault read 1 path data write Trace path write On line test 050A inf3 No ETU response 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F inf1

Incorrect characteristics (FICLIN, FICPG) Line configuration Creation of protection groups Path configuration Line set ES 01 02 03 04 status procedure report status procedure report status procedure report status procedure report

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 56 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

909F

ADETU

0000

050B On OFLTE message On OFLIE message On OFPME message On OFTPE message 050C 050C

Line or path does not exist 01 02 03 04 OFLTE InkNb field OFLIE InkNb field OFPME InkNb field OFPTE InkNb field

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

LOAM rejected on alarm state audit On DFPM message On DGF message On module read On J1 and C2 read 01 02 03 04 RFPMR message cause RGFR message cause state procedure report state procedure report

050D 050C 050F 050F

Protection group does not exist On OCAPS message 01 OCAPS InkNb field

Board fault (loss of two clocks or of applique) Loss of two clocks Loss of redundant applique Loss of primary applique 01 02 03

2.17.2.2.6 MLURM2G penalty posting inf1 Duplex reference inf2 Anomaly number/process number inf3 Service/state

2.17.2.3 End of locavar ETP KO / 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001 phad Diagnostic phase 00 LOCAVAR loading failure 01 LOCAVAR activation failure 02 LOCAVAR diagnostic 03 Failure to load operating software after locavar OK 04 Failure to activate operating software after locavar OK 08 Maximum number of successive OK locavars reached

For phad=00, 01, 03, 04, 08 / 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001
1AA 00014 0004 (9007) A4 ALICE 04.10

npro

Process number

ED

04 3BW 60437 AAAA RKAHA 97 57 / 97

CIT

/ 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

nlds

Service number/service state / 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001

ci

Internal code of message received / 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001

mpcc For phad=2

Class and codm of message originating the failure

/ 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001 pdia Diagnostic (see Appendix C.2 page 91) / 11AF 730C 2102 1100 0800 0200 2001 0101 0202 0102 0102 F400 / 8001 B800 A001 lddi(0:18) Diagnostic information For SMT2G iddi(0) Penalty posted element iddi(1) Test number iddi(2) Sequence number iddi(3) Length of information iddi(418) Diagnostic information For SCH, SMB iddi(0) Test number iddi(118) Diagnostic information

2.17.3 Positioning by operator command / 11AF 7300 2103 11FF 0701 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 coco Command code 00 Interrogate state 01 Create 02 Delete 03 Start locavar tests 04 Position to IND 05 Position to BLOM 06 Position to ES 07 Position to BLOM confirmed 08 Position to IND confirmed

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 58 / 97

CIT

2.17.4 Switchover to standby TU / 11AF 7302 6105 11FF 0012 0901 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 icom icom(0) 00 icom(1) RGTU of stanby TU icom(2) RGTU of backed up TU

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.17.5 Return to normal TU / 11AF 7302 6106 11FF 0012 0603 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 icom icom(0) Error code 00 Succes 02 Negative response from stand by TU 03 No response from standby TU icom(1) RGTU of standby TU icom(2) RGTU of backed up TU

2.17.6 Switchover to standby TU failure / 11AF 7301 2107 21FF 0308 0701 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 icom icom(0) Code derreur 01 Negative response from standby TU (RAB used by another TU of the same type) 03 Non response from standby TU 05 Return to normal TU request for a not backed up TU 06 Internal message inconsistency 07 Programm inconsistency 08 Switch over request on a free standby TU 09 Programm inconsistency 10 Blocking in BASC status (WDOG) 11 RAB bus used by a standby icom(1) RGTU of standby TU icom(2) RGTU of backed up TU icom(3) RTU of standby TU (slot in the rack) Si icom(0)=01,11 icom(4) tuCause (see 2.17.2.2.1.1) icom(5) rtuCause (see 2.17.2.2.1.2) icom(6) alsCause(0) (see 2.17.2.2.1.3) icom(7) alsCause(1) (see 2.17.2.2.1.3)

1AA 00014 0004 (9007) A4 ALICE 04.10

2.18 CODM=AF80 (OIDEF)


This message is sent to central defense when the OM is initialized (complete initialization of the SMM or switchover of the SMM).

ED

04 3BW 60437 AAAA RKAHA 97 59 / 97

CIT

2.18.1 Example 010116/18 H 59 MN 05 EVT=19 :SECUR. INITIALIZAT. /AM = SMMA STT.=ES AF=OCA / 0213 0101 1618 5905 0302 017E 0000 0000 0000 0000 0000 0000 / 11AF 8000 0120 5000 0001 00 2.18.2 Coding of the additional information / 11AF 8000 0120 5000 0001 00 opti : 16 Central defense initialization option 00 NORON System in operation, retrieving station states 01 INION System general initialization 02 MANON All stations set to BLOM Manual operation (initg/redgen disabled) 03 USINE All stations set to BLOM Factory operation (locavar specifics) 05 ICDCN System switchover to new release

/ 11AF 8000 0120 5000 0001 00 etas : 4 iac : 4 nivs : 8 System state Progress indicator, general initialization System operating level

/ 11AF 8000 0120 5000 0001 00 swidft : 16 Switchover origin 0000 Not known (manual reset, RTOS defense) 0001 Soft, operator (CTIBSC) 0002 Hard, after CTIAR 0004 Soft, SUP ASP defense 0005 Soft, OM defense (application IME) 0006 Soft, OM defense (OMAP component) 0007 CTILA failure 0100 Switchover for general initialization 0101 SMMs MIS coupler initialization failure 0102 MIS coupler failure 0103 Software level changing

2.19 CODM=AF82 (OSYNP)


1AA 00014 0004 (9007) A4 ALICE 04.10

This message is sent on general initialization by the ML GX; it indicates the end of switching network initialization.

ED

04 3BW 60437 AAAA RKAHA 97 60 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.19.1 Example 010124/11 H 00 MN 47 EVT=24 :DIFF.SYS STAT. INIG2016 / 0218 0101 2411 0047 0000 0000 0000 0000 0000 0000 0000 0010 / 22AF 8200 00 2.19.2 Coding of the additional information None.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.20 CODM=AF90 (OMIDC)


This message is used inside the OM on: Modification of the system state by operator command. End of a station dump. Software broadcast by operator command. 2.20.1 Example a) System state modification, end of dump 010116/17 H 31 MN 37 EVT=24 :DIFF.SYS STAT. CDPC / 0218 0101 1617 3137 0000 0000 0000 0000 0000 0000 0000 0000 / 80AF 9000 0200 0000 0000 1080 0000 00 b) Software broadcast 010124/15 H 40 MN 56 EVT=10 :START OF /AM = SMTA1 STT.=ES AF=URMA1 / 020A 0101 2415 4056 03E0 0200 0000 / 11AF 9002 00FF 0100 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 / 0000 0060 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 / 0000 00 2.20.2 Coding of the additional information a) System state modification, end of dump / 80AF 9000 0200 0000 0000 1080 0000 00 codi : 16 Internal code 0001 End of memory dump 0002 System state modification by operator command POSIT (MMC) 0000 000E 0000 0000 0000 0000 0000 0000 1000 0000 0000 0000 0000 0000 0000 0A00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

/ 80AF 9000 0200 0000 0000 1080 0000 00


1AA 00014 0004 (9007) A4 ALICE 04.10

For codi=0001 / 80AF 9000 0200 0000 0000 1080 0000 00

ED

04 3BW 60437 AAAA RKAHA 97 61 / 97

CIT

assm : 16 For codi=0002

Station system address

/ 80AF 9000 0200 0000 0000 1080 0000 00 cchg : 16 Change code 0010 System state modification

/ 80AF 9000 0200 0000 0000 1080 0000 00 etas : 4 iac : 4 nivs : 8 System state Progress indicator, general initialization System operating level

b)

Software broadcast / 11AF 9002 00FF 0100 0000 0000 0000 000E 1000 0A00 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0060 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 00

tindl : 16

Release timer

/ 11AF 9002 00FF 0100 0000 0000 0000 000E 1000 0A00 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0060 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 00 nbcc : 16 Number of ML TX contexts enabling the BLOM positioning

/ 11AF 9002 00FF 0100 0000 0000 0000 000E 1000 0A00 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0060 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 / 0000 00 lsta(0:511) : 2 List of stations (two bits per station) 0 Station not concerned 1 Stage upgrade subsystem A 2 Stage upgrade subsystem B excluding PUPE 3 Stage upgrade subsystem B PUPE

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 62 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

2.21 CODM=AFA1 (OMCOS)


This message is broadcast to update FCSM and FCAS in all the SMs. It indicates an extension operation or a reconfiguration. 2.21.1 Example a) Standard format 010124/10 H 55 MN 07 EVT=06 /AM = SMB2 STT.=BLOS / 0206 0101 2410 5507 0481 / 18AF A100 0000 0201 81FF / 0000 0000 0000 0000 C900 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0801 0260 0204 0501 8201 / 8201 5060 0204 0601 8201 / 8202 C860 0204 1601 8201 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 0000 / 0000 0000 0000 0000 00 a) Reduced format When the same OMCOS message generates several events, the first message is complete and subsequent messages are in reduced format. 010124/10 H 55 MN 07 EVT=07 :DEST. RECONFIGURAT. /AM = SMB3 STT.=BLOS AF=TR1+MQ1+GX1+PCA+MR1+CC1+GS1+TX1 / 0207 0101 2410 5507 0482 1000 0000 0000 0000 0000 0000 0000 / 12AF A1 :SOURCE RECONFIGUR. 0000 0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000 0000 0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000 0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000 0000 8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000 0000 0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

1AA 00014 0004 (9007) A4 ALICE 04.10

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

ED

04 3BW 60437 AAAA RKAHA 97 63 / 97

CIT

2.21.2 Coding of the additional information / / / / / / / / / / / / / / / typt : 16 18AF 0000 0000 0000 0000 0000 0000 0000 0000 0801 8201 8202 0000 0000 0000 A100 0000 0000 0000 0000 0000 0000 0000 0000 0260 5060 C860 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000 0201 0000 0000 0000 0000 0000 0000 0000 0000 0501 0601 1601 0000 0000 0000 81FF C900 0000 0000 0000 0000 0000 0000 0000 8201 8201 8201 0000 0000 00 0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000 0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000 8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000 0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

Type of process 0000 Transition to standby station 0001 Reverse procedure 0002 Modification of a stations characteristics Modification of the FCSM and/or FCAS file 0003 Creation of a station 0004 Deletion of a station 18AF 0000 0000 0000 0000 0000 0000 0000 0000 0801 8201 8202 0000 0000 0000 A100 0000 0000 0000 0000 0000 0000 0000 0000 0260 5060 C860 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000 0201 0000 0000 0000 0000 0000 0000 0000 0000 0501 0601 1601 0000 0000 0000 81FF C900 0000 0000 0000 0000 0000 0000 0000 8201 8201 8201 0000 0000 00 0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000 0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000 8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000 0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

/ / / / / / / / / / / / / / /

nfcsm : 16

Number of record items modified in the FCSM file (0 to 4)

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 64 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ / / / / / / / / / / / / / /

18AF 0000 0000 0000 0000 0000 0000 0000 0000 0801 8201 8202 0000 0000 0000

A100 0000 0000 0000 0000 0000 0000 0000 0000 0260 5060 C860 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000

0201 0000 0000 0000 0000 0000 0000 0000 0000 0501 0601 1601 0000 0000 0000

81FF C900 0000 0000 0000 0000 0000 0000 0000 8201 8201 8201 0000 0000 00

0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000

0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000

0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000

8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000

0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000

0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

lfcsm(0:3) .apsm : 16

Number and content of the modified FCSM items Station system address

.fcsm(0:49):8 Content of the FCSM item / / / / / / / / / / / / / / / 18AF 0000 0000 0000 0000 0000 0000 0000 0000 0801 8201 8202 0000 0000 0000 A100 0000 0000 0000 0000 0000 0000 0000 0000 0260 5060 C860 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000 0201 0000 0000 0000 0000 0000 0000 0000 0000 0501 0601 1601 0000 0000 0000 81FF C900 0000 0000 0000 0000 0000 0000 0000 8201 8201 8201 0000 0000 00 0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000 0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000 8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000 0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000 0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

nfcas : 16

Number of record items modified in the FCAS file (0 to 16)

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 65 / 97

CIT

lfcas(0:15) .asml : 16 .fcas(0:5) :8

Number and content of the modified FCAS items Station system address Content of the FCAS item

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 66 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

/ / / / / / / / / / / / / / /

18AF 0000 0000 0000 0000 0000 0000 0000 0000 0801 8201 8202 0000 0000 0000

A100 0000 0000 0000 0000 0000 0000 0000 0000 0260 5060 C860 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000 0000

0201 0000 0000 0000 0000 0000 0000 0000 0000 0501 0601 1601 0000 0000 0000

81FF C900 0000 0000 0000 0000 0000 0000 0000 8201 8201 8201 0000 0000 00

0000 0100 0001 0000 0000 0000 0000 0000 0000 0160 0460 0360 0000 0000

0001 0100 82FF C800 0000 0000 0000 0000 0000 0204 0204 0204 0000 0000

0204 0000 0100 0200 0000 0000 0000 0000 0000 0101 0301 0401 0000 0000

8100 0000 0001 0900 0000 0000 0000 0000 0000 8201 8202 8200 0000 0000

0000 0000 0004 0000 0000 0000 0000 0000 0000 7C60 A860 0000 0000 0000

0000 0000 8210 0000 0000 0000 0000 0000 0000 0204 0204 0000 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0E01 1501 0000 0000 0000

APPENDIX A LIST OF SYSTEM AS

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

A.1 List of system AS


VALUE 0010DF 0DE0FE 102 103 104 105 106 107 108 109 10A 10B 10C 10D 10E 10F 110 111 112 113 114 115 116 117 118 119 11A 11B 11C 11D 11E 11F 12012F 13013F 14014F 150 151 152171 172 173 174 175 176 177 AS UR UR ETA31 ETA1 TR1 TX1 MR1 MR3 MR5 MR7 PUPE MQ2 TR2 TX2 MR2 MR4 MR6 OM OC MQ TR TX MR CC PC GX ETA SM GS MIS MAS1 MAS2 MAS3 MAS4 COMA1COMA16 COMB1COMB16 COM1COM16 PCA PCB PUPE1PUPE32 DIF_SM DIF_GX DIF_DRSAC DIF_DRSTF DIF_OCOCA GR_PUPE VALUE 178 17C 17D 17E 17F 18019F 1C01FF 20023F 24027F 281 282 284 286 287 288 289 28A 28B 28C 2A82AF 2B82BF 2C82CF 2D42DB 2E02E1 2E22E3 2E42E5 2E62E7 2E82E9 302303 30433F 340341 ..... 34E34F 36039F 3E03E1 .... 41E41F 420421 .... 45E45F 460461 .... 47E47F 4804D7 AS DIF_MLCOM GX1 GX2 OCA OCB ETA1ETA32 URM1URM64 URMA1URMA64 URMB1URMB64 HD URM AN COM RCH.BRA RCH.BRB DOM_TR.AB DOM_TR.FSC DOM_TR.AN DOM_TR.EA CC1CC8 CCC1CCC8 GS1GS8 CGS1CGS8 MISAMISB MASA1MASB1 MASA2MASB2 MASA3MASB3 MASA4MASB4 SMMASMMB SMC1SMC60 SMXA1SMXB1 .... SMXA8SMXB8 SMA1SMA64 SMTA1SMTB1 .... SMTA32SMTB32 SMBA1SMBB1 .... SMBA32SMBB32 SCHA1SCHB1 .... SCHA16SCHB16 SMB1SMB88 VALUE 500503 504507 532535 54D56C 56D58C 58E594 5955A4 5A55B4 5B55C4 5C55D4 A80A81 A82A83 A84A85 A86A87 A88A89 AEDAEE AEF AF0AF3 AF6AF7 AF8AFF B01 B02 B03 B04 B05 B06 B07 B08 C20C21 .... C5EC5F C60C7F C80CD7 CD8CF7 CF8D17 D18D27 D28D37 D38D47 D48D57 AS GWA1GWA4 GWB1GWB4 GW1GW4 SMT1SMT32 SMBD1SMBD32 CMR1CMR7 ANA1ANA16 ANB1ANB16 ANAB1ANAB16 ANBA1ANBA16 MISAMISB MAS1AMAS1B MASA2MASB2 MASA3MASB3 MASA4MASB4 FTP1FTP2 DMODI SU2A1SU2A4 CDRA2CDRA1 TRSV8TRSV1 TRSV CDRA SU2A01 UMTS DMODI FTP FTP SU2A02 SMBA1SMBB1 .... SMBA32SMBB32 HD1HD32 SMB1SMB88 HDA1HDA32 HDB1HDB32 MGIA1MGIA16 MGIB1MGIB16 MGIAB1MGIAB1 6 MGIBA1MGIBA1 6

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 67 / 97

CIT

APPENDIX B FAILURE CAUSES (INITIALIZATION AND POSITIONING)

B.1 Common
cause 0001 0002 meaning Negative selftest Transfer fault (DLECM, RLECM) pare(0) rgca Loading source AS Memory area concerned rgca File N pare(1)

0003

Insufficient memory space

rgca

0004

Inconsistent configuration

Memory configuration saved value (ACUTR5) rgsf

0005

MC to private memory transfer error (or incorrect file checksum) Internal error (no response from agent) Error of interchange with the loader

sfca

0006 0007

sfca Loading source AS Loading source AS File N File N

rgsf File N

Error of interchange with loader

0008 0009 000A 000B

Archive inconsistency Incorrect checksum No standby station available for the ML Failure of SOFT switchover causing the ML to be unoperational No response to DPML

tyml / sarc tyml / sarc

000C

Table of expected responses 1 bit per internal ML Destination AS Allocation failure file N mpcc

000D

SM internal transmission failure

000E

Files with fixed addresses overlaid

1AA 00014 0004 (9007) A4 ALICE 04.10

Internal ML number (site) Internal ML number + 16 (system)

ED

04 3BW 60437 AAAA RKAHA 97 68 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

cause 000F
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning No response to DSYNP

pare(0) Table of expected responses 1 bit per component tyml Station register read Anomaly location index Destination AS

pare(1)

0010 0011

Site archive size inconsistent (TX,TR,MQ) Station register KO (=> ACAJB absent)

0012

Anomalies in SM BOOT (equivalent of PFANO)

primitive report mpcc

0013

Transmission on ring failed

0014 0015

Positioning not possible (ML being released) Inconsistent FCDP file Record N tyml / type of fault

001E 001F 0028 0032 0033

Anomaly in MLhypervisor dialog Incorrect DPOS action type Anomaly initializing a PUS by PUP Connection failure No response to DPRS expected from CLTH BY GETU (SMT2G) No response from MASTER GETU to DMAJ message (SMT2G) State of SMT2G switchover controler inconsistent IOS NECTAR link activation failed Sampling test anomaly Hard positioning of the counterpart SMT detected during initialization phase No response to a request ML state transition not possible Incorrect regeneration on counterpart Data inconsistent in second SMe Analysis fault or operating site data inconsistent (URM2G) Inconsistent NCODE for an equipment (URM2G) mpcc tyac

0034

0035 0036 003C 0050

0051 0052 0053 0054


1AA 00014 0004 (9007) A4 ALICE 04.10

0055

0056

ED

04 3BW 60437 AAAA RKAHA 97 69 / 97

CIT

B.2 SMB
cause 0001 meaning Negative selftest pare(0) rgca / rgen pare(1) Cause of OCRAU message File N
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

0002 0004

Transfer fault (DLECM, RLECM) Configuration inconsistent Size of FDVMC file incorrect Index number exceeded in FDVMC file Too many boards Board missing, not supplied Incorrect board (Remote Inventory) MMB bus connection error (FDBSM) Error on number of MMB master (FDBSM) LAB bus connection error (FDBSM) Error on Fmid of active LAB Hardware function error on board Function Prid error, active processor Error finding local FCMAB descriptor Erreur driver ISL (Supply, RI not programmed, RI CHCK, board missing) Board missing, not supplied Too many boards Incorrect board type (tyca) Incorrect upgrade index (ielm) Incorrect hardware variant (varm) Incorrect control mode

tyml / sarc

rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / tgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca

0400 0401 0402 0403 0404 0405 0406 0407 0408 0409 040A 040B 04C2

rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca rgca / rgca Destination reference

0500 0501 0502 0503 0504 0505 Transmitting AS

0005

Transfer error (incorrect RTRAN)

0006
1AA 00014 0004 (9007) A4 ALICE 04.10

No response from agent Selftest report not received (OCRAU) No response to transfer request (DTRAN) No response to DGO (agent activation) rgca / rgem rgca / rgem rgca / rgem 0001 0002 0003

ED

04 3BW 60437 AAAA RKAHA 97 70 / 97

CIT

cause 0008
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Inconsistent archive (file does not exist or not big enough) Incorrect checksum Boot file incorrect checksum

pare(0) tyml / sarc

pare(1) File N

0009

tyml / sarc 0000 Destination AS tyml / sarc tyml / sarc

File N 0000 mpcc

0013

Transmission failure on ring

0015 0080

FCDP file inconsistent No room in interchange memory to transfer a file/no room in private memory to load a configuration file

File N File N

0081

Software configuration inconsistent Incorrect SMB logical number (FCSM, FDCSM) Incorrect EDBSM index (FDTSB, FDBSM) apsm higher than NBE in FCSM Incorrect software map (0 or higher than NBE in FICOB) Incorrect ML list extension (FCSM, FELML) Incorrect component descriptor index (FICOB, FDCOB) Incorrect component type (FICOB) ML present and not described in FICOB map Processor not described in FICOB map Incorrect basic software type (FICOB) Type of software incorrect or not described (FICOB, FPLB) Incorrect TYSMB (FCSM, FDTSB) Incorrect SMB logical number (FCNFA) 0000 0001 0002 0003 0000 0000 0000 0000

0004 0005 0006 0007 0008 0009 000A

0000 0000 0000 0000 0000 0000 0000

000B 000C

0000 0000

0082

Handler call negative report Fmid activation (hlcf_fm_act) Group activation (hlpl_megr_act) Message transmission (hlcm_mes_emi) Message receipt (hlcm_mes_rec) 0000 0001 0002 0003 report report report report

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 71 / 97

CIT

cause 0083

meaning Primitive call negative report Message transmission (Phemsg) Message reception (Phdmsg)

pare(0)

pare(1)

0000 0001 tyml / sarc tyml / sarc

report report File N File N

0084 0086

Bootsm data file not in FCMAB Incorrect file base address (0 or greater than space allocated) Incorrect first free address (ADB0 greater than space allocated) Insufficient memory allocation file size (FZMA, FDFMI, FMAP, FCATB) Incorrect file existence criterion (FIDL lcrit) Incorrect file dimensioning law (FIDL loi2) File allocation law incorrect or incompatible with logical segment (FIDL ss and loi1) Logical group incorrect or does not exist (FIDL ngrl, FICOB) Logical segment not described in FMAP or not described in FPLB

0087

tyml / sarc

File N

0088

tyml / sarc

File N

0089 008A 008B

tyml / sarc tyml / sarc tyml / sarc

File N File N File N

008C

tyml / sarc

File N

008D

tyml / sarc

Segment N/component or TYML or group File N File N

008E 008F

Fixed address does not exist or is incorrect Cannot allocate memory (insufficient size) (since allocation performed by logic segment enter segments first file Id) Cannot allocate pagetables No memory space to calculate pagetable No memory space for pagetables

tyml / sarc tyml / sarc

0090

0000 Map N in FDFMI tyml / sarc

RGCA/RGEM RGCA/RGEM

0091

Memory allocation failure at fixed address (since allocation is by logic segment, give the identification of the segments first file) SST initialization timeout

File N

00B0

Number of media to be initialized Domain N

Number of media replied

1AA 00014 0004 (9007) A4 ALICE 04.10

00B1

Insufficient media to go in service

Number of media in service

ED

04 3BW 60437 AAAA RKAHA 97 72 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

cause 00B2
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Insufficient links to go in service

pare(0) rgca AAETH

pare(1) N of external domain Link N (1 / 2) Response table 1 bit / agent Response table 1 bit / agent Response table 1 bit / agent

00B3 00B4

Negative selftest on ethernet link No response to DGO message

rgca AAETH Response table 1 bit / agent Response table 1 bit / agent Response table 1 bit / agent

00B5

No response to DINIT message

00B6

No response to DSYNE message

B.3 ML TR, TX, MQ


cause 0002 meaning Transfer fault (DLECM, RLECM) (transmission failure, no response) Archive inconsistent (file does not exist, FIEXT inconsistent, FICVMR inconsistent) Site archive site inconsistent (TX,TR,MQ) (address outside allocated space) Inconsistent FCDP file (FCDP and FIAF inconsistent) Anomaly in MLhypervisor dialog Incorrect DPOS action type Anomaly when processing DPML (INDL cannot be positioned) Anomaly initializing a PUS by PUP (DSYNP/RSYNP failure) No response to a request (no response to DPSP) Incorrect FIAF (site archive) cannot load (ADBF to 0) mpcc.clas mpcc.codm tyac / tych pare(0) Loading source AS File N pare(1) File N

0008

tyml or loading source AS

0010

Loading source AS Record N

File N

0015

tyml / type of fault

001E 001F 0023

0028

0051

0064
1AA 00014 0004 (9007) A4 ALICE 04.10

File N

Loading source AS

ED

04 3BW 60437 AAAA RKAHA 97 73 / 97

CIT

cause 0065

meaning CDC and TRSV server version inconsistency (DVERS/RVERS interchange) No TRSV (TCP/IP connection opening failed) (OIASE KO)

pare(0)

pare(1)

0066

B.4 ML COM1G
cause 0002 meaning Transfer fault (FETLR initialization on counterpart) Transfer fault (FDILR initialization) Transfer fault (FETLR initialization on MLGX) 0004 0008 000A 001E Configuration inconsistency Archive inconsistency No standby station for FETLR initialization Incorrect positioning message File open failure Message transmission anomaly pare(0) 0010 0011 000F rgca / rgca 0014 0000 0 report report pare(1) A831 A831 A831 report rgca 0000 40 / tyac File N mpcc AD21 DPML AFE1 OPRAP A0C9 DLRMO 00FF FOTCP AF31 OPML A09A DMAJX A831

Message transmission anomaly (FETLR on counterpart) Message transmission anomaly (FDILR) Message transmission anomaly (FETLR on GX) 0032 Connection failure Incorrect LR number received in RMAJX Return on connection failure

0010

0011 000F

A831 A831

LR received VT

LR expected report

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 74 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

cause 003C
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Anomaly in sampling test RGTR module of RCMT set to locavar Connection in RCMT Sampling in RGID Test pattern Disconnection in RCMT Connection failed (RCMT locavar deleted in basic subrack) RCMT in extension rack set to locavar RCMT in extension rack locavar deleted

pare(0)

pare(1)

0000 NRCSM/01 NRCSM/02 NRCSM/03 NRCSM/04 NRCSM/05

report report report pattern report report

NRCSM/06 NRCSM/07

report report

B.5 MLGX
cause 0004 meaning Type of place in service action incompatible with state Type of set to unavailable action incompatible with state File read failed (DLECF/RLECF) Destination AS File N tyac File N pare(0) pare(1)

0014

001E

0052

File open failure Inconsistent action type

0053

Incorrect regeneration on counterpart RCOPF timeout RCOPF KO FCOPF timeout FCOPF KO 0001 0002 0003 0004 0000 report 0000 report

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 75 / 97

CIT

B.6 ML COM2G
cause 0004 meaning Incorrect response to RCCFG network configuration request No response to RCCFG network configuration request Inconsistent action type pare(0) report pare(1) ETU address
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

0051 0052

mpcc

B.7 ML HD
cause 0002 000D 0014 001A 001F meaning Data regeneration from counterpart unit failure OABAS timeout Positioning to unavailable rejected by active Positioning to unavailable rejected by standby Fault on audit of counterpart (standby unavailable and active not in service) pare(0) Proccess n pare(1) Fault n

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 76 / 97

CIT

B.8 ML PC, ML PUPE


cause
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning

pare(0)

pare(1)

0004

PC/PUPE software initialization stoppage (same as cause 0067) MLPUPE soft switchover failure on receipt of EPTRA KO st Station N us Usi N cr Message report For the TMRT Usi Transfer in progress (CSEC message) Partition to be transferred not ES or circuit group transfer in progress on partition Transfer in progress, TAPP partition failure (CBLOP message) Transfer in progress, TRPPA or TCEPA timeout MLPUPE soft switchover failure on no CTRAP or CTRAA response uuuu List of messages expected (1 bit / USI) st Station N MLPC soft switchover failure on receipt of ECTRA KO st Station N us Usi N cr Message report MLPC soft switchover failure on no CTRAC response st Station N uuuu List of messages expected (1 bit / USI) ML soft switchover failure on deferred restart following ML PC switchover st Station N ML PUPE soft switchover failure following receipt of EATRA KO st Station N cr Message report us Usi N 9st0 crus

000B

01us 02us 03us 04us

Astu

uuu0

Bst0

crus

Cstu

uuu0

Dst0

0000

Est0

crus

000C

ML PC or PUPE initialization failure (same as cause 0069) PC/PUPE software initialization stoppage EPARI KO received on active PC st Station N 1 PCA, 2 PCB, 3 to 31 PUPE1 to PUPE29 ex Exception N us Usi N 1st0 exus

0067

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 77 / 97

CIT

cause

meaning EPARI KO received on standby PC or PUPE No response to CIPAR on active PC uuuu List of messages expected (1 bit / USI) PC PUPE 8000 ZELM 4000 EXCE 2000 EOBL 1000 RGTR 0800 TMRT RURE 0400 RUGR TDIS 0200 RSDT RUCN 0100 STSC RUDT 0080 XFOC TSIG 0040 NGMT TAPP 0020 EOBC RSAS 0010 STPC STSR 0008 AGCA 0004 RGTS 0002 EGES NTRF 0001 SPDA No response to CIPAR on standby PC or PUPE No response to CFINI on active PC Initialization stopped on end of reduced UTC loading following detection of ML UTC subsystem A out of service Initialization stopped on end of UTC initialization following detection of ML UTC out of service No RMOTR message received (ML TR) No RSYNP received from ACMPR sa List of messages expected (1 bit / coupler) 20 coupler subaddress 2 10 coupler subaddress 3 08 coupler subaddress 4 04 coupler subaddress 5 02 coupler subaddress 6 01 coupler subaddress 7

pare(0) 2st0 3stu

pare(1) exus uuu0


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

4stu 5stu 6st0

uuu0 uuu0 0000

7st0

0000

8000 9st0

0000 00sa

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 78 / 97

CIT

cause

meaning Receipt of RSYNP KO message from ACMPR s ACMPR subaddress (2 to 7) cr Cause File open failure Process initialization Context seizure Component initialization Interface 2.1 initialization Incorrect TDM test (AGLAX loopback) Watchdog timeout Register initialization in AGLAX No channel assigned to PQUICC Error in RVTM file c Cause t TSM l LR Negative report (Phaslr) Null coupler address Incorrect coupler address (station) Incorrect coupler subaddress No coupler address in the file No response to EPPIL on active PC EPPIL KO received on active PC

pare(0) Ascr

pare(1) PUPEL information File N Process N Process N

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

As01 As02 As03 As04 As05 As06 As07 As08 As09 Bctl

information

B1tl B2tl B3tl B4tl B5tl Estu Fst0

report

uuu0 exus

0068 0069

No standby station available for ML ML PC or PUPE initialization failed

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 79 / 97

CIT

cause 0069

meaning EPARI KO received st Station N ex Message exception N us Usi N Watchdog timeout for updating replicated and semipermanent data of the preloaded SMBs ML PC st Station N No response to CIPAR st Station N uuuu List of expected messages (1 bit / USI) Watchdog timeout for data broadcast st Station N Call to file broadcast (EXREDIF) during CIPAR / EPARI interchanges stu Station N and USI N 10 NGMT 08 TMRT 04 RUGR 02 EGES 01 EDEF nf Total number of files buffered na Number of calls No RSYNP received from ACMPR coupler st Station N sa List of expected messages (1 bit / coupler) RSYNP KO message received from ACMPR s Subaddress of ACMPR (2 to 7) cr Cause File open failure Process initialization Context seizure Component initialization Interface 2.1 initialization Incorrect TDM test (AGLAX loopback) Watchdog timeout Register initialization in AGLAX No channel assigned to PQUICC

pare(0) 2st0

pare(1) exus
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

3st0

0000

4stu

uuu0

5st0

0000

8stu

nfna

9st0

00sa

Ascr

PUPEL information File N Process N Process N

As01 As02 As03 As04 As05 As06 As07 As08 As09

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 80 / 97

CIT

B.9 ML MR, CC, GS


cause
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning No response to request for synchronization between components (DSYNT, RSYNT) Site data initialization failure DIDOT/RIDOT interchange failure with the GES process (GES / GFIC process incorrectly initialized, no TR, TX loading source) DMOTR/RMOTR interchange failure with ML SM DFIDF/RFIDF interchange failure with ML TR Site data upload failure

pare(0)

pare(1)

005A

005B

0000

FFFF FFFE File N tyml / sarc

005C

Context regeneration failure (CONFL inconsistencies, no counterpart ML response) Interchanger synchronization KO (no response to DSYNC message)

005D

B.10 ML URM2G
cause 0002 meaning Transfer fault (DLECM, RLECM) pare(0) Loading source AS File N pare(1) File N

0008 0050

Archive inconsistency Hard positioning of counterpart SMT detected during init phase No response to a request Cannot switch to ML state (eg: BLOM > INDL for active SMT) Incorrect regeneration on counterpart Second SMe data inconsistency

0051 0052

MPCC

0053 0054 0055

UR ALR

IT NCODE

Analysis fault or site data inconsistency detected by URM2G operating software CMIC inconsistent PCM type inconsistent with its UR type Equipment extension request on nonIRM PCM 0100 0200 0300 04it rgmi rgmi FCAIT rec. N FCAIT rec. N

1AA 00014 0004 (9007) A4 ALICE 04.10

Channel associated TS creation, ABO or TDAF on PCM link without signaling it TS N

ED

04 3BW 60437 AAAA RKAHA 97 81 / 97

CIT

cause

meaning TS0 or TS16 of a PCM link used with signaling for channel associated TS ABO or TDAF CAREQ TS inconsistent or NCODE inconsistent FIMIC variation other than PIMI on modifying PCM UR, ALR or ADET inconsistent (values outside limits) Inconsistency detected in FIMIC: two different RGMI with the same URALR pair Inconsistency detected in FIMIC: two different RGMI with the same ADET CSE or URA2G active PCM link described in FIMIC with ALR other than 0 or 1 al ALR N CSE or URA2G passive PCM link described in FIMIC with ALR other than 2 or 3 al ALR N Request to create a CSE or URA2G passive PCM link when no active PCM link is declared on the UR ur UR N Tex supporting two PCM links of a CSE or URA2G UR are not managed by the same secondary component Tex supporting two ACTIVE PCM links of a CSE or URA2G UR are on the same ETU File overflow during a write access File open error by PHOPEN PCM context inconsistent with counterpart Creation of equipment on extension rejected because the PCM link is inconsistent with the site data To correct the fault, delete the PCM link and its equipment and then recreate the PCM link and the equipment with consistent data ti Type of inconsistency (1=PCM, 2=TS) Modification of a PCM link on extension rejected because the PCM link is inconsistent with the site data To correct the fault, delete the PCM link and its equipment and then recreate the PCM link and its equipment with consistent data

pare(0) 05it

pare(1) FCAIT rec. N


All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

06it 0700 0800 0900

FCAIT rec. N rgmi rgmi rgmi

0A00

rgmi

0Bal

rgmi

0Cal

rgmi

0Dur

rgmi

0Eur

rgmi

0Fur

rgmi

1000 1100 1200 13ti

File N File N rgmi rgmi

14ti

rgmi

1AA 00014 0004 (9007) A4 ALICE 04.10

Software inconsistency 0056 NCODE inconsistent for one equipment

FF00 UR ALR IT NCODE

ED

04 3BW 60437 AAAA RKAHA 97 82 / 97

CIT

cause 0057
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Insufficient size for the context POOL (review LGE and LGA of FCTXi) CDL not possible because of the new software index ii Software index before CDL jj Software index after CDL

pare(0) Process FCTX N Process FCTX N

pare(1) LGE required in FIAF iijj

B.11 ML URM1G
cause 0004 meaning Configuration inconsistency Main load (ICPRO PRI) Aux. A load (ICPRO AUX A) Aux. B load (ICPRO AUX B) TTC load (ICCTM) Module 0 load (ICMOD 0) Module 1 load (ICMOD 1) Module 2 load (ICMOD 2) Module 3 load (ICMOD 3) Module 4 load (ICMOD 4) Module 5 load (ICMOD 5) Module 6 load (ICMOD 6) Module 7 load (ICMOD 7) Process activation Loading FSM No LOGUR response (ICPRO PRI) pare(0) 0003 0001 0002 0003 0004 0005 0006 0007 0008 0009 000A 000B 000C 000D 000E 0002 0003 pare(1)

0006

B.12 ML AN, MGI


cause 0002 nnnn tt 0004 meaning Transfer fault (DLECM, RLECM) File n Ml type pare(0) 00nn pare(1) nntt

ML component configuration inconsistency More than eight MLANI secondary components More than eight MLAN_L components 01xx 02xx

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 83 / 97

CIT

cause 0008

meaning Archive inconsistency Not enough record numbers File N Record not long enough Record not long enough Item not long enough Invalid chaining type Chaining type Null file number

pare(0)

pare(1)

01nn

nnxx

nnnn

02nn 03nn 04nn 05nn

nnxx nnxx nnxx nncc

cc

06xx

0050

Hard positioning of counterpart SM detected during initialization phase No response to a request No response to DGO AS of component that has not responded Number of responses received No response to DSYCS No response to DIDOS No response to DIRST Receipt of RIDOS KO response Crt. RIDOS Receipt of RIRST KO response Crt. RIRST 01aa aann

0051

aaaa nn

02aa 03xx 04xx 05cc

aann

cc

06cc

cc

No response to the request to regenerate contexts 0052 Cannot switch to ML state (Eg: BLOM >INDL if counterpart ML is not ES) Crash following general restart Station number: 1 or 2 INDL positioning by operator INDL positioning by system 0053 0056 Regeneration failed

07xx

01ss

ss

02ss 03ss

Station or archive configuration inconsistency No ML AN_L component 01xx 02xx 03xx

1AA 00014 0004 (9007) A4 ALICE 04.10

Duplex reference does not exist Null site data file address

ED

04 3BW 60437 AAAA RKAHA 97 84 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

cause 0057
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Process initialization fault ASML inconsistent (secondary component) pp Processor number ss Subaddress Primitive call inconsistent Parameter number inconsistent Context file open failure Process context too big Application context too big Number of FGPRO file records inconsistent Problem initializing the application context file Call to PSCPRO error FGPRO file already initialized FGREF file already initialized Switchover number too high Max size of FODIF file Switchover number FODIF file already completed Switchover number Reduced resource type Reduced resource type in FODIF

pare(0)

pare(1)

01pp

ssxx

02pp

rrxx

rr

03pp 04pp 05pp 06pp 07pp 08pp 09pp 0App 0Btt rrxx

tt rr

0Crr

aabb

rr aa bb

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 85 / 97

CIT

cause 0058

meaning Incorrect file initialization Problem initializing a buffer file File N Problem opening a file (PHOPEN) Problem with size of an application system management file Problem with size of FADAC file Inconsistent number of records in files FSGAN and FGRAN Inconsistent number of records in files FSCMI and FCXMI Inconsistent number of records in files FSCUP and FRCXU Phldon failure for FADAC initialization FANUR file undersized FINST file undersized

pare(0)

pare(1)

01nn

nnxx

nnnn

02nn 03nn

nnxx nnxx

04nn 05xx

nnxx

06xx

07xx

08xx 09xx 0Axx

0059

Anomaly, HARD SMe switchover request after counterpart switched to NES Serious anomaly in switchover phase ML AN release failed because simplex context unstable or instability counters not valid nnnn Number of simplex process types blocking release Awaiting AN switchover authorization criteria aaaa Number of ANs still to be switched over Switchover failure Double AN switchover during instantaneous switchover rrrr Type of resource during instantaneous switchover Double AN switchover during single switchover rrrr REFSSU of TAP resource during single switchover 01nn nnxx

005A

02aa

aaxx

03aa 04rr

aaxx rrxx

05rr

rrxx

005B

Incorrect site data initialization (no TRAD response, file size or content incorrect) RLECF message timeout while loading site data on counterpart nnnn File N 01nn nnxx

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 86 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

cause

meaning RLECF or RTNAN message timeout while loading site data on translator RMLLR message timeout while loading MQ data aa Number of timeouts FAFCH file read problem Detection point number

pare(0) 02nn

pare(1) nnxx

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

03aa

04aa

aa

VERSI not found in FPAAN when generating the AN parameters file (FPAUR) aa VERSI sought VERSP not found in FPAAN when generating parameter file aa VERSP sought Operation requested on unknown site data aa Operation code bb Operation type cc Pattern : 0 : global, 1 : single Unauthorized operation requested on site data ACHILL characteristics read problem No ACHILL coupler configured RLECF KO received File N Record N Item N RTNAN KO received Entity RTNAN report File full aa File N Version (VERSI) inconsistent Identifier Entity Inconsistent file size File N

05aa

06aa

07aa

bbcc

08xx 09xx 0Axx 0Baa bbcc

aa bb cc

0Caa

bbxx

aa bb

0Daa

0Eaa

aabb

aaaa bb

0Fnn

nnxx

nnnn

Problem processing an RLECF by counterpart aa File N bb Record N cc Item N


1AA 00014 0004 (9007) A4 ALICE 04.10

10aa

bbcc

Counterpart ML AN dialog error FKPAD file not long enough

11xx 12xx

ED

04 3BW 60437 AAAA RKAHA 97 87 / 97

CIT

cause 005C nnnn

meaning File sizing error File n

pare(0) 00nn

pare(1) nnxx
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

B.13 ML ETA
cause 0008 0060 0061 0062 0063 0064 meaning Archive inconsistency PHLDON failure Configuration inconsistency : more than PQUICC AS Configuration consistency : no Pquicc AS Configuration inconsistency : FTRFsize DSP process initialization failure 0001 : Phopen 0002 : Pscpri 0003 : Psipro LA n File n Pscpri RC Psipro RC crdsp AS MLSM pare(0) File n pare(1)

0065 crdsp 0001 0002 0003 0004 0004 0005 0006 0007 0008 0009 0066 cc ff

Serious LA fault Error cause no FTEST response FTEST KO response RCHECK no FCHECK response software checksum KO country data checksum KO parameters checksum KO overwriting counter overflow interface test KO non FINIT response

RIDSP KO 16*ODBT1 counter + RIDSP KO counter NFONC

ccff

AS ULI Eta

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 88 / 97

CIT

APPENDIX C PDIA : LOCAVAR DIAGNOSTIC

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

C.1 Station Locavar


pdia 00 01 02 03 04 06 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 20 23 24 26 28 29 2A 2B 2C 2D 2E 2F meaning No diagnostic Board, applique or SAB fault Locavar loading error BSM bus fault Multiple fault Configuration fault BSM fault with priority penalty posting Doubt concerning each RCMT of the SMX Doubt concerning each RCID of the SMX Doubt concerning clocks from STS Doubt concerning RAID adapter (plug) Doubt concerning LCXE cable and on RAMT adapter board Doubt concerning each odd numbered RCMT Doubt concerning each even numbered RCMT Problem on SMT interlogic link Doubt concerning clocks from SMX Doubt concerning ring connected to penalty posted coupler Doubt concerning ICID mutual backup links Doubt concerning AAISM board of penalty posted coupler Crossover on token ring wiring Doubt concerning RSIMT board Doubt concerning boards connected to the BETP bus (ICTSM, ETU, ISTHE1, ISTHR1 boards) Fault on ISL link ACAUX mod 0 (ISL00, ISL01, ISL02) Fault on ISL link ACAUX mod 1 (ISL10, ISL11) Doubt concerning boards connected to the BETP bus (ICTSM(s), ETU, ISTHE1, ISTHR1) Fault in applique behind ETU board Fault on one of the penalty posted boards, one of the appliques behind the boards or the GLR cable (if the SAB board is indicated) Fault on one of the penalty posted boards, an applique behind the boards or the AEI cable AEI cable position fault Fault on one of the boards connected to the ISL00 bus (basic shelf) Fault on one of the boards connected to the ISL01 bus (extension shelf, subrack 4) Fault on one of the boards connected to the ISL02 bus (extension shelf, subrack 3) Fault on one of the boards connected to the ICL00 bus (basic shelf)

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 89 / 97

CIT

pdia 30 31 32 33 34 35 36 37 38 3A 3B 3C 3D 3E 3F 40 41 42 44 45 74

meaning Fault on one of the boards connected to the ICL01 bus (extension shelf, subrack 4) Fault on one of the boards connected to the ICL02 bus (extension shelf, subrack 3) Fault on one of the boards connected to the ISL10 bus (extension shelf, subrack 2) Fault on one of the boards connected to the ISL11 bus (extension shelf, subrack 1) Fault on one of the boards connected to the ICL10 bus (extension shelf, subrack 2) Fault on one of the boards connected to the ICL11 bus (extension shelf, subrack 1) Fault on LAHA or LAHqA link of an ETU Fault on LAHB or LAHqB link of an ETU Fault on standby ICL Fault on LAH0 link seen from network Fault on LAH1 link seen from network LAH fault downstream or at loop seen from an ALS ETU LAH fault upstream seen from an ALS ETU Top module fault Bottom module fault RAB bus fault SMBA 24M clock fault (fault on SMBA IAILA applique or ETU) SMBB 24M clock fault (fault on SMBB IAILA applique or ETU) SAB function mutual backup fault seen from control function Alarm on non ETU element Fault on one of the boards penalty posted or one of the other appliques connected to the LAB bus

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 90 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

C.2 ETU Locavar


pdia
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Fault on board or applique or GLR Configuration fault Timebase fault SAB function mutual backup fault seen from network ETU or ICIDS A fault ETU or ICIDS B fault ETU or ISTHE1 SMTA fault ETU or ISTHE1 SMTB fault ETU fault on standby side or associated CLTH ETU applique fault ETU or GLR board or applique fault GLR subsystem fault (SMB) Fault, no AEI response AEI wiring fault LAHA or LAHqA link fault seen from a parent ETU LAHB or LAHqB link fault seen from a parent ETU Standby ICL fault LAH0 link fault seen from network LAH1 link fault seen from network LAH fault downstream or in loop seen from ALS ETU LAH fault upstream seen from ALS ETU Top module fault Bottom module fault RAB bus fault Standby faulty, ALS fault Standby faulty, RAB fault Standby faulty Standby not available

01 06 13 1B 21 22 23 24 25 28 29 2A 2B 36 37 38 3A 3B 3C 3D 3E 3F 40 F0 F1 F2 F3

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 91 / 97

CIT

APPENDIX D LIST OF ANOMALIES

FT 00 40 90 12 22 32 52 62 72 92 B2 D2 23 53 63 73 A3 64 35 45 55 65 06 16 26 36 46 56 66 76 B6 C6 D6 E6 F6

Name NONREC OANAU OANAX ODETA OFIPR ORINA OFORG OFANA OFNRM OFACO OFNDE ODTET OFTES OFINT OFCHO OFLTT OFBOU OFDTX ODIVC ODIVE OFSUC OFFIC OCAMA OPSEA OFSEA OMSEA OFSLA OFIPA OPLIA OPLGA OPSLA OMSLA OFURA OFSPR OCLIX

Anomaly Message not recognized by OM UR message inconsistent GX message inconsistent Buffer timeout Program inconsistent Unexpected response Unit not accessible Message incorrect No response to request No correspondent Exclusivity not available ML TR timeout TESO fault Table inconsistent Time inconsistent Charge rate read File loop Observation task overflow Divergences in extensions taken Charge count divergences Connection supervision FICLX file Timeout incoming No incoming interregister signaling Terminating equipment interregister signaling Inconsistent incoming interregister signaling Incoming line signaling Permanent pulse incoming No release incoming No release guard incoming No line signaling incoming Inconsistent incoming line signaling Signaling on UR incoming Signaling on calling line PO Operator signaling fault port

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 92 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

FT 07 17 27 37 47 57 67 77 87 97 A7 B7 C7 D7 E7 F7 08 18 28 38 48 58 68 78 88 98 A8 D8 E8 F8 69 79 F9 0A 1A 3A 4A 5A 6A 7A BA FA

Name OCAMD OPSED OFSED OMSED OFSLD OFIPD OPLID OPLGD OPITM OPCDP OPITL OPSLD OMSLD OFURD OFSPE OCLIC OFIDT OFTIN OPTEC OPTEX OPTEN OPREN OMMEX OMMIN OMMES OPMES OFOMI OFSCS OFSUT OFSTM OTRAC OMAPE OCOLA OFEXT OFRMQ OFHAM OFMES OFDTS OFTTS OFREM OSIGN OFIS

Anomaly Timeout outgoing No outgoing interregister signaling Outgoing interregister signaling Outgoing interregister signaling inconsistent Outgoing line signaling Permanent pulse outgoing No release outgoing No release guard outgoing No proceedtosend No seizure check outgoing No proceedtosend on line No line signaling outgoing Inconsistent outgoing line signaling Signaling on UR outgoing Called line PO signaling anomaly Manufacturer signaling fault report ML TX identification Macro internal fault No buffer to interchange unit No buffer to ocx No buffer to register No register response Inconsistent message received from ocx Inconsistent message received from MR Inconsistent message received from MR No message Interpreter software CSN dialog anomaly TUP anomaly MTP anomaly Debug trace Debug trace LA link fault URA2G interchange fault MQ receive fault Hamming code fault No signaling message received Signaling timeout with switchover Signaling table process No periodic message Signaling table fault Isolation fault

1AA 00014 0004 (9007) A4 ALICE 04.10

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

ED

04 3BW 60437 AAAA RKAHA 97 93 / 97

CIT

FT 0B 1B AB CB DB EB EF 0C 1C 3C 3C 4C 5C 6C BC CC DC EC 0D 1D 2D 3D 4D 5D 6D 7D 8D 9D

Name ODPTE ODIAG ONOBA ODORA ODDQS ODCAB ODCOR OFANO OFROC OFOIN OFILO OFIFI OFRIN OFNRD OFTMS OFTRA OFIDO OFDUR OFTSM OFFML OFAML OFEXP OFTAN OFSIG OFTER OFSGT OFINA OFPV5

Anomaly URA2G fault with test request URA2G unsolicited diagnostic message No switchover Associated unit failure Service quality failure Complete subscriber failure Complete unit failure URA2G anomaly No periodic PC message received Incorrect message Software inconsistency File inconsistency File inconsistency No response to request Signaling message transport Frame service Cannot transfer data Manufacturer maintenance Transport with SM penalty posting ML fault without penalty posting ML fault with penalty posting Operation Transport with ring penalty posting Signaling table fault Termination fault trace TCAP anomaly INAP anomaly V5.2 or ISDN anomaly

1AA 00014 0004 (9007) A4 ALICE 04.10

ED

04 3BW 60437 AAAA RKAHA 97 94 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

APPENDIX E MAIN MLSM NUMANO

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

numano 0006 002A

meaning Destination AS does not exist Change of ISL alarm state (01) (01) (23) (45)

infs(06) Destination AS 0001 FFF5 rgca

003D

Software exception

Use the results of DMPIL For SMB, analyze SITSFG Use the results of DMPIL For SMB, use SITSFG

003E

Software watchdog

0041 0047

OPEN command failed on two adapters Double ring switchover (multiplex out of service) Traffic switchover following adapter failure Adapter initialization failed LA link out of service Difference between internal date and broadcast date Incorrect file checksum (1) Memory type 01 Common memory 02 Private memory tyml sarc File N Number of MLs on overload ndch etch asml of the first ML overloaded rgca rgca Counter penalty posted asml rgca

0050

0054 0071 0084

0092

(2) (3) (45) 009A Permanent overload (0) (1) (2) (34) (01) (01) (23) (01) (6)

009B 009C

Missing board Audit of single fault counters

009E

Audit of agents

009F
1AA 00014 0004 (9007) A4 ALICE 04.10

Audit of interrupt vectors Audit of routing tables Audit of component descriptors

00A000A2 00A300A9

ED

04 3BW 60437 AAAA RKAHA 97 95 / 97

CIT

numano 00BC

meaning Hardware fault or bus error on main coupler One ring HS and the other BLOM Data rate on one ring incorrect Data rate on two rings incorrect File open failed (ETU software) Mapping impossible in ETP memory BETP audit BETP / ISL multiple fault BETP / ICL / ISL fault ETP catalog construction error Serious fault in Prom or BootSm Serious fault on secondary agent (0)

infs(06) Use the results of DMPIL For SMB, analyze SITSFG

00C0 00C5 00C6 00E0

Ring number (0=A,1=B)

00E3 00E4 00E8 00EB 00EC 00FE 00FF

Use the results of DMPIL Analyze icmat and iclog For SMB, analyze SITSFG

0104 0105 0106

68302 / 68360 watchdog Buffer memory parity fault Hard switchover IT received on active SMT Memory parity fault detected by audit (0) (1) (2) (4) (56) sens2 tyml sarc rgca icmat (04) nfic Token ring number x0=MISA x1=MISB x2=MASA1 x3=MASB1 x4=MASA2 x5=MASB2 x6=MASA3 x7=MASB3 Token ring number Token ring number

0192

01C1

Limit of HS channels exceeded

01C3
1AA 00014 0004 (9007) A4 ALICE 04.10

Token ring adapter insertion failure Token ring adapter unsolicited deinsertion

sens2 sens2

01D0

ED

04 3BW 60437 AAAA RKAHA 97 96 / 97

CIT

All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

numano 01D2
All rights reserved. Passing on and copying of this document, use and communication of its contents not permitted without written authorization from Alcatel.

meaning Token ring data rate inconsistent Multiple out of service Adapter failure (IT check) Adapter failure (lobe wire fault) Adapter failure (Scb Clear) Command failure on adapter Initialization failure sens2 sens2 sens2 sens2 sens2 sens2 infs(01) B4 B5 infs(23)

infs(06) Token ring number Token ring number Token ring number Token ring number Token ring number Token ring number Cause No RGO response No RINIT received asml

01D7 01D8 01D9 01DA 01DD 01FA

0200207 0208 020920A 0219 021A 021B 021C 021D221 0222 0230 0233 0237 0238 0239

Psos fault Pna+ configuration failed Ethernet driver fault Pna configuration does not exist FCPLE inconsistent Ni OCB installation IP routing Ethernet ULI fault Ntp ULI fault Nma initialization error Station cannot be inserted Ethernet address duplication IP address duplication SNMA frame inconsistent

END OF DOCUMENT