U N I N T E RRU P T I B L E P O W E R SU P P L I E S (U P S) + L I G H T I N G F L O W D I M M E R- S TA B I L I SE R S + V O LTAG E S TA B I L I SE R S & P O W E R L I N E C O N D I T I O N E R S + D C P O W E R S Y S T E M S + S TAT I C I N V E R T E R S + P H O T O V O LTA I C I N V E R T E R S

PRODUCT RANGE CATALOGUE


MARCH 2011

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

CONTINUOUS, CLEAN AND RELIABLE ELECTRICAL POWER SUPPLY


Electronics and telecommunications are more and more present in our daily lives, on both the professional and personal level. The fact of having a quality electrical power supply will therefore be essential in any of the areas of activity, above all considering that in such a competitive world as this, total availability will be essential for the success of any business. We must as well further environment-respectful electricity generation, promoting energy efciency, via energy saving plus renewable energy solving. SALICRUs job is to assure this energy availability with maximum quality and reliability.

QUALITY AS A STANDARD
The SALICRU Quality and Environmental System is structured and adapted to assure that the manufactured products and services offered adapt to the legal and regulatory requirements and meet the clients needs and expectations and all environmental requirements. Quality, prevention of pollution and respect for the environment are a common objective of all SALICRU staff. SALICRU is concerned with the continuous improvement of environmental management, and with minimising and suitably managing waste and energy consumption and promoting recycling.

UNIVERSAL SOLUTIONS
According to different studies, 40% of faults occurring in computer systems are caused by disturbances in the electrical power supply (far more than those caused by computer viruses) also affecting productivity losses derived from inactivity and the resources needed for restoring the damage caused.

Types of electrical disturbances


Transitory. Micro cuts voltage downtimes. Surges. Troughs. Gradual low voltage. Power supply failure. Harmonics. High frequency interferences. Frequency variations.

Types of applications
We can also nd unending other applications liable to be affected, just like the computer environments, by electrical disturbance on all areas of professional and personal life. So, on the other hand, we also avail solutions within energy efciency -public lighting energy saving- along with renewable energy range -photovoltaic solar energy-. Domestic use: PC, peripherals, modem-fax-telephone, TV/LCD, domotics, HDD-external, DVD, etc. Small trades/ofces: PC/MAC, fax-copiers-scanners, SPT, telesurveillance, hubs, routers, etc. Medium and large companies: Servers, work stations, telephonyVOIP, internetworking, data storage, data processing centres, calculation centres, etc. Industrial activity: Monitoring, handling, telecontrol, safety, alarm, process control, continuous production lines, analysis, laboratory, numerical control, etc. Telecommunications: Data centres, internet centres, land line telephony infrastructure, mobile telephony switching stations, radiotelevision broadcasters, transmission-reception equipment, etc. Lighting: Public lighting, car parks, tunnels, motorways-freeways, shopping centres, industrial estates, etc. Infrastructures: Electro medicine, emergency lighting-ventilation, military applications, security, transport, electrical stations and sub-stations, etc. Photovoltaic Solar Energy: Residential, commercial, industrial, big centrals, etc.

SALICRU

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

WE OFFER ALL OF OUR RESOURCES TO YOU


The accumulated experience of more than 45 years, with more than 600,000 units in operation, facing innumerable professional challenges, have allowed SALICRU to acquire the experience and knowledge that guarantee the solutions in the forms of advisory, support, manufacture and management. NATIONAL PRESENCE: Delegations and Service & Technical Support BARCELONA BILBAO GIJN LA CORUA LAS PALMAS DE G. CANARIA MADRID MLAGA MURCIA PALMA DE MALLORCA PAMPLONA SAN SEBASTIN SEVILLA VALENCIA VALLADOLID ZARAGOZA

INTERNATIONAL PRESENCE: Branches and Distributors, with Sales, Service & Technical support. CHINA FRANCE HUNGARY MEXICO ALGERIA ARGENTINA BELGIUM BRAZIL CHILE COLOMBIA CUBA CZECH REPUBLIC DENMARK ECUADOR EGYPT GERMANY HOLLAND INDONESIA IRELAND JORDAN KUWAIT MALAYSIA MOROCCO PERU PHILIPPINES POLAND RUSSIA SAUDI ARABIA SWEDEN SWITZERLAND THAILAND TUNISIA UAE URUGUAY VENEZUELA VIETNAM PORTUGAL SINGAPORE UNITED KINGDOM

UNINTERRUPTIBLE POWER SUPPLIES (UPS)

LIGHTING FLOW DIMMER-STABILISERS

VOLTAGE STABILISERS AND

DOMESTIC USE SMALL OFFICES


APPLICATIONS INTERFERENCES SOLUTIONS APPLICATIONS

SME / BIG CORPORATIONS


INTERFERENCES SOLUTIONS APPLICATIONS

INDUSTRY
INTERFERENCES SOLUTIONS APPLICATIONS

TEL
EMi/RE

INTER

CAR HOME CINEMA TV PHOTOCOPIER PHONE/FAX PERIPHERALS PC/SERVER SWITCH/ROUTER

DC/AC ENERGY CONVERSION VOLTAGE PEAKS VOLTAGE PEAKS + MAINS FAILURES VOLTAGE PEAKS + MAINS FAILURES + OVER/UNDERVOLTAGES

SPS AUTO SPS SAFE SPS HOME SPS SOHO SPS ADVANCE

WORKSTATIONS INTERNETWORKING PERIPHERALS SERVERS

VOLTAGE PEAKS + MAINS FAILURES + OVER/UNDERVOLTAGES + BLACKOUTS + FREQUENCY VARIATIONS VOLTAGE PEAKS + MAINS FAILURES + OVER/UNDERVOLTAGES

SLC TWIN SLC CUBE3 SLC ELITE SLC ELITEMAX

TOOL MACHINE

VOLTAGE PEAKS + OVER/UNDERVOLTAGES

PROCESS CONTROL VOLTAGE PEAKS + MAINS FAILURES + OVER/UNDERVOLTAGES MANOEUVRING AND TELEMANAGEMENT CONTINUOUS PRODUCTION LINE

SPS SOHO SPS ADVANCE

SWITCHBOARD INTERNET

SPS HOME

VOLTAGE PEAKS + SLC TWIN MAINS FAILURES + SLC CUBE3 OVER/UNDERVOLTAGES + SLC ELITE BLACKOUTS + FREQUENCY VARIATIONS SLC ELITEMAX

TRANSMISSION AND COMMUNICATION EQUIPMENT TELEPHONY RADIO AND TV SYSTEMS VoIP

VOLTA MAINS OVER/UND BLA ENERGY (AC/D

5 3 1 6 4

SPS AUTO/SAFE

SLC TWIN

SLC CUBE3

DC/AC CONVERTER 150 W ACTIVE PROTECTOR 2.300 W

OFF-LINE UPS 400 VA - 600 VA

LINE-INTERACTIVE UPS 400 VA - 2000 VA

SINEWAVE LINE-INTERACTIVE UPS 750 VA - 3000 VA

SINGLE PHASE PARALLELABLE ON-LINE DOUBLE CONVERSION UPS 700 VA - 20 kVA

THREE PHASE ON-LINE UPS 7,5 kVA - 80 kVA

SLC ELITE/ELITE MAX

SPS HOME

SPS SOHO

SPS ADVANCE

THREE PHASE ON-LINE UPS 60 kVA - 300 kVA

D POWER LINE CONDITIONERS

DC POWER SYSTEMS

STATIC INVERTERS

PHOTOVOLTAIC INVERTERS

LECOM
SOLUTIONS APPLICATIONS

INFRASTRUCTURES
INTERFERENCES SOLUTIONS

ENERGY EFFICIENCY
APPLICATIONS PROFITS SOLUTIONS APPLICATIONS

RENEWABLE ENERGY
PROFITS SOLUTIONS

RFERENCES

AGE PEAKS + S FAILURES + DERVOLTAGES + CKOUTS + CONVERSION DC - DC/AC)

OPTIMUS FAC P CS-IS CS-WAVE MDL

AIRPORTS SEAPORTS TUNNELS HOSPITALS RAILWAYS ROADWAYS

VOLTAGE PEAKS + MAINS FAILURES + OVER/UNDERVOLTAGES + BLACKOUTS + FREQUENCY VARIATIONS

SLC TWIN SLC CUBE3 SLC ELITE SLC ELITE MAX

STREET LIGHTING AIRPORTS SEAPORTS CAR PARKS TUNNELS SHOPPING CENTERS MOTORWAYS

LIGHTING ENERGY SAVING

ILUEST ILUEST+

RESIDENTIAL COMMERCIAL INDUSTRIAL

PHOTOVOLTAIC ENERGY

EQUINOX

7 1

2 6 5

6
ILUEST+
CS-IS/WAVE MDL
OPTIMUS/FAC P

EMi2

RE

DC POWER SYSTEMS 300 W - 170 kW

DC/AC INVERTER 500 VA - 20 kVA

SERVOMOTOR VOLTAGE STABILISER 5 kVA - 330 kVA

LIGHTING FLOW DIMMERSTABILISER 7,5 kVA - 45 kVA

LIGHTING FLOW DIMMERSTABILISER 3,5 kVA - 120 kVA

WWW.SALICRU.COM

EQUINOX

ILUEST

ELECTRONIC VOLTAGE STABILISER 300 VA - 250 kVA

PHOTOVOLTAIC INVERTER 2,8 kW - 10 kW

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SPS AUTO
SPS AUTO: In the car as at home
The SALICRU SPS AUTO is an inverter that gives alternating voltage of 230 volts / 50 Hz starting with direct voltage of 12 volts provided by a car or boat battery. Moreover, ts USB port for 5 Vdc direct little device feed. It combines a small size, identical to that of a refreshment can, aluminium surround and a power adapted to the most common portable units. The input connection is lighter type and the output euro plug / american to be able to connect any load. It is the ideal companion for any trip or daily work, taking away the concern with having the batteries of the different portable devices always loaded.

APPLICATIONS: Availability of alternating current in any place


Enjoy your trip by car or boat without worrying about the state of the your mobile battery or the charge in your digital camera. With an SPS AUTO you will always have a power supply available through your vehicle battery. You can supply or charge: Digital cameras, video cameras, video consoles, laptop PCs, PDAs, iPods, mobile phone chargers, battery chargers, portable refrigerators, GPSs, small electrical appliances such as epilators, shavers, sterilisers, food heaters, videos, DVDs, small TVs, lamps, fans, etc.
Data may change without previous notice (*) Spain only (**) Rest of World

USB connection detail

TECHNICAL SPECIFICATIONS
MODEL
TECHNOLOGY CONTROL INPUT OUTPUT DC Input Voltage Maximum consumption Voltage Wave shape Frequency Power Cont. output / instant. max. power OUTPUT DC ALARMS PROTECTION Low battery shutdown Output short-circuit Input reverse polarity Fuse Thermal protection GENERALS Cooling Consumption without load Efciency Input connection Enclosure Outlet type STANDARDS Safety Electromagnetic Compatibility (EMC) Marking Quality and Environmental management Voltage Intensity

ASK FOR LOCAL CONDITIONS

YEARS

SPS.AUTO
High frequency inverter (HF) By microprocessor 10 15 V 15 A 230 V 5% Simulated sinewave 50 Hz 5% 150 W (30 minutes) 100 W / 200 W 5V 500 mA Low battery, low input voltage, overvoltage, overload and overtemperature. 10 Vdc 0.5% By microprocessor By means of fuse 15 A (spare part included) 50 C 0.5% Air natural 250 mA 90% Lighter connector / 12 Vdc Aluminium Schuko (4 & 6 mm) / American 5-15P EN-60950-1 EN-55022; EN-61000-6-1 CE ISO 9001 and ISO 14001 TV

SPS AUTO

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM609C01 CODE 401AB000501 ED. JANUARY 2011
STATIC INVERTERS

WARRANTY

UNIN T E RRUP T IBL E P OW E R SUP P L IES (UP S) + L IG H T ING F L OW DIM M E R - S TA B IL ISE RS

+ VOLTAGE S TA B IL ISERS & P OW E R L INE C ONDI T IONERS + DC P OW E R S Y S T E MS + S TAT IC IN V E R T E RS + P HO T O VOLTA IC IN V E R T E RS

SPS SAFE
SPS SAFE: Overload, surge and atmosphere discharge electric protect
SALICRUs SPS.SAFE electric active protector range optimum overload solving, surges, electric parasites and lightning side-effects. Full range ts following advantages: overload protect, EMI/RFI lter, phone / data line protect, all mains duly xed for easy connection and include shutter for kid protect, all models include cable-marking plus cable-tie for greater comfort, all models include on indicators and overload control, plus all models include all-connect guarantee insurance up to 60,000. SALICRUs SPS.SAFE series models are the best allies for office and home electronic protect: PC, printer, scanner, photocopier, router, hub/switch, external HDD, fax, modem, phone, TV/LCD, home cinema, Hi-Fi, DVD, SAT, TDT, domotics, videoconsole, electric home appliances, .

SPS.SAFE 6+
6 schuko mains with EMI/RFI lter. Overload + phone protect. Extra space for great dimension mains. Electric equipment guarantee: 30,000.

SPS.SAFE BOOK
6 schuko mains with EMI/RFI lter. Overload + phone protect. Folding design for connection ease. USB 2.0 double charger (1A). Electric equipment guarantee: 50,000.

SPS.SAFE 7+
7 schuko mains with EMI/RFI lter. Overload + phone protect. Cable wrap-organizer device. Extra space for great dimension mains. Electric equipment guarantee:40,000.

TECHNICAL SPECIFICATIONS
MODEL
Nominal current

YEARS
ASK FOR LOCAL CONDITIONS

SPS.SAFE6+ SPS.SAFE7+

SPS.SAFE BOOK

SPS.SAFE MASTER

10 A (2,300 W) 230 V AC 50 / 60 Hz 775 V 918 Joules between Ph-N, N-T and Ph-T 36,000 A 6,000 V < 1 ns Frequency range 150 kHz - 100 MHz / Reduction till 40 dB Yes Yes Yes Yes Yes Yes Yes
RJ-11 160 Joules RJ-11 160 Joules Combo RJ-45/RJ-11 RJ-11 160 Joules

SPS.MASTER
Master / Slave intelligent electric protect. 5 schuko mains (1 Master + 4 Slave). Connected equipment automatic on / off. EMI/RFI lter. Overload + phone protect. Hub USB 2.0 (1 in / 4 out). Electirc equipment guarantee:60,000.

Nominal voltage Maximum voltage Maximum energy dispersion Maximum voltage Maximum current peak Response time EMI/RFI lter Re-arm switch On/Off switch Overload control indicator On indicator Wall x option Socket kid-protect Phone / fax / modem protect Mains tted for connection ease Safety Marking Quality and Environmental Management

No

Yes

Yes IEC-60884-1;EN-61643-11;EN-61643-21 CE ISO 9001 and ISO 14001 TV


(*) Spain only (**) Rest of World

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM609C01 CODE 401AB000501 ED. JANUARY 2011
VOLTAGE STABILISERS

Data may change without previous notice

WARRANTY

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SPS HOME

OFF-LINE UPS 400 VA & 600 VA SPS HOME: Full protection for ofce and domestic units

The numerous types of electrical disturbances (e.g. mains failures, power cuts, blackouts, over-voltages,) arising from the various causes (e.g. storms, lightning, excessive demand, natural disasters, accidents etc...) present problems to all electricity users, and a constant challenge to all computer users who depend on a correct and stable power supply to be able to work safely and efciently. Electrical problems are responsible for the largest number of faults in computer systems, far more even than those caused by computer viruses. The best solution is therefore to seek protection with an Uninterruptible Power Supply. The SALICRU SPS HOME series Uninterruptible Power Supply, with off-line technology, come in power ratings of 400VA and 600 VA and are the best possible protection for both domestic and professional single-post computer environments. Each UPS provides 6 output sockets with sufcient capacity for the central unit and all of the associated peripherals. In order to achieve greater total protection, telephone/ADSL protection is provided, preventing the entry of over-voltages and/or electrical noise through the telephone line. Completing the overall protection, the UPS units come complete with monitoring and le closing software to facilitate orderly shutdowns in the event of extended power cuts. The SALICRU SPS HOME series UPS are also recommended for multimedia audio-visual environments for entertainment and domestic leisure.

PERFORMANCE
Off-line technology. Multiple base design with 6 schuko sockets. 4 sockets with UPS protection; all sockets with over-voltage protection. On/Off multifunction pushbutton. Self-detection of 50 or 60 Hz frequency. LEDs indicating mains, battery mode and battery failure. USB port for monitoring and le closing software. Telephone/ADSL line protection by RJ-45 port. Batteries user replaceable. Cold Start function. Autotest every start up Anchoring for wall xture. Automatic restart after each power cut and at the end of autonomy. Economic guarantee for connected units up to 70,000.

SPS HOME equipment

APPLICATIONS: Versatile protection for single-post environments


Designed in multiple base format, the SPS HOME series UPS have 6 schuko bases duly turned to enable trafo connections and with child protection by obturators, with a capacity in computer systems to protect both the PC and all of its associated peripherals (screen, printer, external hard disk, router, ) and TV and other components in multimedia systems (decoder, DVD, home cinema, Hi-Fi, TDT, ).

UNINTERRUPTIBLE POWER SUPPLIES (UPS)

SPS HOME
DESCRIPTION
1. 2. 3. 4. 5. 6. 7. 8. 9. 4 x UPS sockets. 2 x over-voltage protection sockets. On/Off multifunction pushbutton. LED indicators. AC input. USB port. RJ-45 telephone/ADSL protection. Protection breaker. Anchoring for wall xture.

OFF-LINE UPS 400 VA & 600 VA


YEARS
ASK FOR LOCAL CONDITIONS

TECHNICAL CHARACTERISTICS
MODEL
TECHNOLOGY INPUT
Nominal voltage Voltage range Nominal frequency Frequency range Frequency self-detection

SPS HOME
Off-line 230 V Up to 170V 265V 50 or 60 Hz 10% Yes 230 V 10% 50 or 60 Hz 1% Pseudo sinusoidal Schuko 4 2 2/6 ms Breaker, user-resettable AC mode and battery mode Immediate interruption 480 joules, 2 ms Tel / Fax, modem, ADSL internet + Ethernet 10/100 Mb Sealed, lead-calcium, free-maintenance, useful life 3-5 years 8 hours Up to 20 minutes By the user Against deep discharge Fuse against short-circuit Yes Every start up Yes Green LED Yellow LED Red LED Audible alarm every 5 seconds Audible alarm every second Permanent alarm USB Monitoring and management for the Windows, Linux, Unix and Mac Up to 95% without condensing 0C +40C <40 dB EN-62040-1-1; EN-60950-1 EN-62040-2 CE ISO 9001 and ISO 14001 TV
Data liable to changes without prior notice

OUTPUT

Voltage Voltage precision (1) Frequency (1) Frequency precision (1)

9 2 1 3 4
PROTECTION

Wave form (1) Socket type No. sockets with autonomy + protection No. sockets with protection Transfer time Input Overload Short-circuit Protection against peaks Data line

8 7 6 5

BATTERY

Type Recharging time Autonomy Replacement Protection

WINPOWER software
UPS monitoring and management software for closing les/applications. Supports Windows, Linux, Unix and Mac.
FUNCTIONS

Cold Start Autotest Automatic restart

INDICATIONS

Mains present Battery mode Battery failure

ALARMS

Battery mode output Low battery (end of autonomy) Inverter failure

COMMUNICATION Port
Software

GENERALS

Maximum altitude Relative humidity Temperature Acoustic noise @ 1 metre

3,500 m.a.s.l.

STANDARDS

Safety Electromagnetic compatibility (EMC) Marking Quality and Environmental Management

(1) Battery mode.

COMPLETE solution
SPS HOME series UPS.
UPS/PC USB connection wire. WinPower software CD. Instructions manual. Warranty certicate. Economic guarantee.

RANGE
MODEL
SPS.400.HOME SPS.600.HOME

UPS POWER
(VA / W)
400 / 200 600 / 300

TOTAL POWER
(VA / W)
1.150 / 1.150 1.150 / 1.150

DIMENSIONS
(D x W x H mm.)
295 x 120 x 85 295 x 120 x 85

WEIGHT
(Kg)
3,2 3,5

SALICRU warranty
On-line registry at www.salicru.com. 2-year warranty. Batteries covered by the warranty.
(*) Spain only (**) Rest of World

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM773A01 CODE 401AB000563 ED. JANUARY 2011 UNINTERRUPTIBLE POWER SUPPLIES (UPS)

WARRANTY

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SPS SOHO

LINE-INTERACTIVE UPS 400 VA - 2000 VA SPS SOHO: The best electrical protection for information systems

The SALICRU SPS SOHO series includes all the necessary performance for improved protection of computer equipment. The SPS SOHO series are uninterruptible power supply systems (UPS) with line-interactive technology available in 400, 600, 800, 1000, 1400 and 2000 VA. The permanent stabilisation of the input voltage causes less use of the batteries to achieve maximum autonomy if necessary. For better integration in the protected environment, they also include USB communication with complete monitoring and control software capable of automatically turning off the systems in the event of long cuts. They also include as standard a powerful display with information on the input voltage, output voltage, charge level, battery level and operation status. And for complete protection, they include a lter for the data/modem/ADSL line. All of these features make them the UPS solution with the best quality/price ratio on the market.

SPS SOHO models

LCD Display

PERFORMANCES
A complete display with all of the necessary information. Line-interactive, microprocessor-controlled technology. Permanent stabilisation with Boost / Buck technology. Cold Start function. Battery can be changed by the user, HotSwap function. USB communications port. Monitoring and management software included. Protection of RJ-45 data / modem line. Automatic restart function after a mains cut. Load connection by schuko-type sockets. Protection against overloads, short-circuits and transients.

APPLICATIONS: The best ally of information technologies


The high value of the information stored and managed by computer systems and the high indexes of disturbance in the electrical supply (cuts, micro cuts, uctuations,...) make the SPS SOHO series UPS an essential element in protecting your computer systems. Your PCs, servers and other peripherals can offer you maximum output if they are well protected.

UNINTERRUPTIBLE POWER SUPPLIES (UPS)

SPS SOHO
DESCRIPTION
1. 2. 3. 4. 5. AC input. Output bases. USB communication port. Data/ADSL line protection. Thermal input protection.

LINE-INTERACTIVE UPS 400 VA - 2000 VA


YEARS
ASK FOR LOCAL CONDITIONS

TECHNICAL SPECIFICATIONS
MODEL
TECHNOLOGY INPUT
Nominal voltage Voltage range Nominal frequency Frequency auto-sensing Stabilization

SPS 400 / 600 / 800 SOHO SPS 1000 / 1400 / 2000 SOHO
Line - interactive 220 V, 230 V, 240 V Up to 162 V 290 V 50 / 60 Hz Yes Buck / Boost 230 V 10% 50 / 60 Hz 1 Hz Simulated sinewave Schuko 2 2 / 6 ms. Rearm thermal AC and battery modes Immediate shutdown Tel / fax, modem, ADSL internet + Ethernet network 10 / 100 Mb Sealed lead acid batteries, maintenance free, average life 3-5 years 6 - 10 hours up to 90% Up to 20 minutes Up to 40 minutes By user Against deep discharge against short-circuit through fuses Yes Yes, after end of autonomy Yes Input voltage / output voltage Connected load / overload / battery capacity Normal / Battery / AVR (stabiliser) Beep every 10 seconds Beep every second Beep every 2 seconds Beep continuously Beep every 0.5 seconds USB 2400 m.a.s.l. Up to 95%, non-condensing 0 C +40 C <40 dB <45 dB EN-62040-1-1; EN-60950-1 EN-62040-2 EN-62040-3 CE ISO 9001 and ISO 14001 TV
Data liable to changes without prior notice.

OUTPUT

Voltage Voltage accuracy (1) Frequency


(1)

5% for load < 50% (2)

Frequency accuracy (1) Wave shape (1) Outlet type Outlet quantity Transfer time

PROTECTION
400 / 600 / 800 models

Input Overload Short-circuit Data line (RJ-45)

BATTERY

Type Recharge time Autonomy (3) Replacement Protection

FUNCTIONS INDICATORS

Cold Start Automatic restart LCD multifunction Displayed values Levels

1000 / 1400 / 2000 models

Operating modes

ALARMS

Battery mode output Low battery (end of autonomy) Battery replacement Fault Overload

CONTROL software
UPS monitoring and management software. Supplied on CD and valid for the Windows, Linux and Mac families.
COMMUNICATION GENERALS

Port Software Maximum altitude Relative humidity Temperature Acoustic noise at 1 metre Safety Electromagnetic Compatibility (EMC) Operating Marking Quality and Environmental management

Monitoring and management for Windows family, Linux and Mac

STANDARDS

Flow diagram

(1) Battery mode (2) 10% for SPS.1000.SOHO (3) PC + LCD 15

COMPLETE solution
SPS SOHO series UPS. UPS / PC USB communication cable. Monitoring software CD. Data line / modem / ADSL cable. Instructions manual. Warranty certicate.

RANGE
MODEL
SPS.400.SOHO SPS.600.SOHO SPS.800.SOHO SPS.1000.SOHO SPS.1400.SOHO SPS.2000.SOHO

POWER
(VA / W) 400 / 240 600 / 360 800 / 480 1000 / 600 1400 / 840 2000 / 1200

DIMENSIONS
(D x W x H mm.) 330 x 100 x 140 330 x 100 x 140 330 x 100 x 140 405 x 145 x 205 405 x 145 x 205 405 x 145 x 205

WEIGHT
(Kg) 5 6 6,5 9 9,5 10

SALICRU warranty
2-year warranty. Batteries covered by the warranty. Possible extension of the warranty.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM606A01 CODE 401AB000381 ED. JANUARY 2011 UNINTERRUPTIBLE POWER SUPPLY (UPS)

(*) Spain only (**) Rest of World

WARRANTY

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SPS ADVANCE

LINE-INTERACTIVE UPS 750 VA - 3000 VA SPS ADVANCE: Flexibility at the service of electrical protection

The SALICRU SPS ADVANCE series is a line-interactive UPS with pure sinusoidal output, available in 750, 1000, 1500, 2000 and 3000 VA and designed for easy conguration by the user in tower and 19 rack format. The front panel includes LCD display and four pushbuttons for easy monitoring, and ve measurers, three status indications and 9 alarms.

LCD panel

SPS ADVANCE models

PERFORMANCES
Control by high-reliability microprocessor. Sinusoidal output. High frequency design. Stabiliser with boost and buck technology. Extendable autonomy for the 1500, 2000 and 3000 VA models. Battery charging depending on temperature, ABM function. Batteries can be replaced by the user. Selectable output range and line sensitivity. Cold Start function. Potential-free contacts / RS-232 / USB port. Monitoring software for Windows, Linux and Mac. RJ-11 / RJ-45 Data line protector. Management by SNMP protocol with remote monitoring by web browser. Protection against overloads, short-circuits and overheating. 2 in 1 Rack / Tower design for all models.

Battery replacement

Assembling conversion design for rack

APPLICATIONS: Computer environments always safe


The SPS ADVANCE series will provide high level protection for computer environments for small and medium sized enterprises: PCs, servers, work stations and other network equipment. This series protects your most sensitive electronic units against problems in the electrical supply, including surges and troughs, peaks, prolonged voltage downtimes, and faults in the electrical network.

UNINTERRUPTIBLE POWER SUPPLIES (UPS)

LINE-INTERACTIVE UPS 750 VA - 3000 VA


ASK REPOSICIN POR FOR LOCAL CONDITIONS DEL PRODUCTO

EQUIPMENT connectivity
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Modem / Transitory protection. RS-232 / Optocouplers. USB port. AC protection. AC IEC-type output. Slot SNMP / AS-400. Emergency stop (E.P .O.). Input magnetic thermal switch. AC output. AC input. External battery connector. Output thermal protection.

AO R Y E AS S

VLIDO EN ESPAA Y PORTUGAL

TECHNICAL SPECIFICATIONS
MODEL
POWER (W) INPUT
Voltage Volatge range Acceptable voltage range Transference to batteries due to low mains (Wide mode) Transference to batteries due to high mains Stabiliser mode Boost Buck

750 / 1000 VA 1500 / 2000 VA


500 / 700 1050 / 1340

3000 VA
2100

220 / 230 / 240 V 0 300 V 154 / 161 / 168 V 4% 264 / 276 / 288 V 2% If the input V decreases more than 10%, the output V is increased 12% If the input V increased more than 10%, the output V is decreased 11% 50/60Hz 5Hz on normal mode; >40Hz on Generator mode 230 Joules 250 Joules 220 / 230 / 240 V 5% RMS 50 / 60 Hz 0.1 Hz Pure sinewave 110% shutdown after 3 minutes; 150% shutdown after 5 cycles 110% shutdown after 30 seconds; 120% shutdown after 5 cycles 2 4 ms AGM sealed, and maintenance free 10 minutes 3 hours at 90% LCD panel Beep every 4 seconds Beep every second Continuous beep Beep every second Beep every second 0 C +40 C Up to 45%, non-condensing <40 dB <45 dB Windows family, Linux and Mac platforms Yes Yes Optional N/A EN-62040-2 EN-62040-3 CE ISO 9001 and ISO 14001 TV Yes EN-62040-1-1; EN-60950-1
Data may change without previous notice.

Frequency range Transient absorption capacity

OUTPUT

Voltage Voltage accurancy (Bat. mode) Frequency Frequency accurancy (Bat. mode) Wave shape Overload Line mode Battery mode

750 / 1000 VA models

1500 / 2000 VA models

TRANSFER TIME Inverter-mains BATTERY


Battery type Typical back up time (2) Recharge time

INDICATORS AUDIBLE ALARMS

Autonomy mode Low battery UPS fault Overload Battery replacement

ENVIRONMENT

Operating temperature Relative humidity Acoustic noise at 1 metre Monitoring Software RS-232 Optoacouplers USB SNMP E.P.O.

INTERFACE
3000 VA model

Yes

SPS.16.STS
BBM (Break Before Make) static transfer system for power supply redundancy. Priority net select. Software conguration (RS-232 + relays). 1U rack format.
STANDARDS

Safety Electromagnetic Compatibility (CEM) Operating Marking Quality and Environmental managament

OPTIONS
External battery charger for extended autonomy (1500 / 2000 VA). 19 rack assembly kit. Temperature + humidity measurer for units with internal SNMP. (1) Temperature measurer for units with internal SNMP. (1)

RANGE
MODEL
SPS.750.ADV SPS.1000.ADV SPS.1500.ADV SPS.2000.ADV SPS.3000.ADV
(3) Dimension per module

POWER
(VA / W) 750 / 500 1000 / 700 1500 / 1050 2000 / 1340 3000 / 2100

DIMENSIONS
(D x W x H mm.) 386 x 86 x 235 386 x 86 x 235 414 x 86 x 217 (x 2) (3) 414 x 86 x 217 (x 2) (3) 582 x 86 x 438

WEIGHT
(Kg) 10,5 10.5 21 21 33

COMMUNICATIONS
Internal SNMP card. (1) External SNMP external card. AS-400 card. (1)
(1) Above 1500 VA.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM576A01 CODE 401AB000357 ED. JANUARY 2011
UNINTERRUPTIBLE POWER SUPPLIES (UPS)

(*) Spain only (**) Rest of World

WARRANTY GARANTA

SPS ADVANCE

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SLC TWIN

ON-LINE DOUBLE CONVERSION UPS 700 VA - 20 kVA SLC TWIN: Parallel supply for single phase loads

The SALICRU SLC TWIN series has been conceived to provide the necessary exibility to the range of medium power UPS, as it is here where it is necessary to combine leading protection with the capacity to adapt to the different applications. Therefore the most important services of the SLC TWIN series is its capacity to grow in parallel up to 3 units, with or without redundancy, in order to achieve real upgrading and thus avoid having to change the UPS in greater qualitative and quantitative demands from the different consumers. The range is made up of units with single phase input from 700 VA to 10 kVA or three-phase from 8 to 20 kVA , always with single phase output. Moreover, amongst many other advantages, the series includes a rectier with Soft Start, working at inaudible switching frequency at 20 kHz, power factor > 0.98 (1) and output precision better than 1%. (1)

PERFORMANCES
On-line double conversion technology. Parallel operation without any need for centralised bypass. (1) Parallel capacity up to 3 units. (1) Parallel cable, standard. (1) Possible extended autonomies. Battery test, standard. Rectier with PFC (power factor corrector) and Soft Start. Power factor > 0.98. (1) Manual bypass interruption-free. (1) Separator transformer. (2) PWM inverters and IGBT transistors. Control panel with block diagram, LCD display and keyboard. Communications extended with RS-232 (standard), USB (2), SNMP (2) and AS-400 (2) ports. MODBUS communications protocol. (2) Standard monitoring software. Models in 19 rack up to 6 kVA.

SLC TWIN

SLC TWIN RACK 19

APPLICATIONS: High line power supply for medium powers


Information losses in computer environments are caused in 45% of cases by problems in the electrical supply, without counting the losses in productivity derived from the inactivity and the resources needed to restore the damage caused. All processes that require a reliable, continuous, quality power supply are protected and supplied by a SALICRU SLC TWIN series UPS. Especially conceived to protect departmental networks, work stations and their associated peripherals, servers, VOIP telephony, industrial processes, medical equipment, etc.

(1) Depending on the model (2) Optional

UNINTERRUPTIBLE POWER SUPPLY (UPS)

SLC TWIN
DESCRIPTION
1. 2. 3. 4. 5. 6. 7. 8. 9. AC input. AC output. Maintenance bypass. RS-232 interface. Intelligent slot (SNMP USB, AS-400). , Data line protection RJ-11/RJ-45. Battery module connection. Input protection. Parallel port.

ON-LINE DOUBLE CONVERSION UPS 700 VA - 20 kVA


TECHNICAL SPECIFICATIONS
MODEL
FORMAT TECHNOLOGY INPUT
Nominal voltage Voltage range Frequency Frequency range Power factor Rectier structure 0,98 (2) PFC with Soft Start 220 / 230 / 240 V 1% steady state; 2% transient state 1 Hz / s Mains present 4 Hz; free running 0,05 Hz (2) > 88% at full load 2% (linear load) ; 6% with non-linear load (in accordance with EN 62040-3) Up to 130% for 10 minutes; >130% for 1 second 3 to 1 220 / 230 / 240 V 15% 50 / 60 Hz 4 Hz Up to 130% permanently; >130% for 1 second Sealed, maintenance free Against overvoltages, under voltages and alternating current component PWM P/U (Constant power - Constant voltage) 7 hours up to 90% RS-232 0 C +40 C Up to 95%, non-condensing 2400 m.a.s.l. <60 dB <45 dB(2) EN 62040-1; EN 60950-1; EN 60529 EN 62040-2 VFI in accordance with EN 62040-3 CE ISO 9001 and ISO 14001 TV
(4) On-line mode (3) Voltage availability of 110 / 115 / 120 / 127 V

YEARS
ASK FOR LOCAL CONDITIONS

SLC TWIN 700 VA - 10kVA SLC TWIN/3 8 kVA - 20kVA


Tower or rack (2) 220 / 230 / 240 V (3) 176 276 V 50 / 60 Hz 4 Hz 0,95 Tower 3 x 380 / 400 / 415 V 3 x 304 478 V On-line, double conversion, PFC, double DC bus

OUTPUT

Nominal voltage Voltage accuracy Maximum slew rate Synchronisation Efciency Total harmonic distortion (THDv) Permissible overloads Crest factor

BYPASS

Nominal voltage Permissible voltage range Permissible frequency range Overload

BATTERIES CHARGER

Battery type Protection Technology Charge type Recharging time Ports Monitoring software Operating temperature Relative humidity Operating altitude Acoustic noise level at 1metre Safety Electromagnetic compatibility (EMC) Operating Marking Quality and environmental management

8 hours up to 90%
Data may change without previous notice.

6 kVA tower model

COMMUNICATION GENERALS

For platforms Windows, Linux and Mac

2 kVA tower model

STANDARDS

(2) Depending on the model 1 kVA rack model

RANGE
TOWER MODEL
SLC - 700 - TWIN SLC - 1000 - TWIN SLC - 1500 - TWIN SLC - 2000 - TWIN SLC - 3000 - TWIN SLC - 4000 - TWIN SLC - 5000 - TWIN SLC - 6000 - TWIN SLC - 8000 - TWIN SLC - 10000 - TWIN SLC - 12000 - TWIN SLC - 15000 - TWIN SLC - 20000 - TWIN

ADAPTABILITY
Extended autonomies. (1) Galvanic isolation. (1) Other input / output voltages. (1) Tower or 19 rack format. Single or three-phase input. Redundant parallel system 4 kVA.

POWER
(VA / W)

DIMENSIONS
(D x W x H mm)

WEIGHT
(Kg)

INPUT/OUTPUT
II / II II / II II / II II / II II / II II / II II / II II / II II III / II II III / II III / II III / II III / II

COMMUNICATIONS
RS-232 interface. Monitoring software. SNMP adapter / Web. (1) AS-400 card. USB port card. (1) MODBUS protocol. (1) Temperature-humidity sensor. (1)

700 / 490 1000 / 700 1500 / 1050 2000 / 1400 3000 / 2100 4000 / 2800 5000 / 3500 6000 / 4200 8000 / 5600 10000 / 7000 12000 / 8400 15000 / 10500 20000 / 14000

410 x 145 x 220 410 x 145 x 220 470 x 195 x 347 470 x 195 x 347 470 x 195 x 347 575 x 260 x 717 575 x 260 x 717 575 x 260 x 717 575 x 260 x 717 575 x 260 x 717 575 x 260 x 717 (x 2) 575 x 260 x 717 (x 2) 575 x 260 x 717 (x 2)

13 14 30 31 32 84 87 90 92 93 48 + 131 49 + 131 50 + 131

RACK 19 MODEL
SLC - 700 - TWIN R SLC - 1000 - TWIN R SLC - 1500 - TWIN R SLC - 2000 - TWIN R SLC - 3000 - TWIN R SLC - 4000 - TWIN R SLC - 5000 - TWIN R SLC - 6000 - TWIN R
Values for standard autonomies.

POWER
(VA / W)

DIMENSIONS
(D x W x H mm)

WEIGHT
(Kg)

INPUT/OUTPUT
II / II II / II II / II II / II II / II II / II II / II II / II

SERVICES
Pre-sale and after sale advisory service. Multiple formulae for maintenance and telemaintenance (SICRES).
(1) Optional

For other congurations, consult dimensions and weights.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM629B01 CODE 401AB000403 ED. JANUARY 2011 UNINTERRUPTIBLE POWER SUPPLY (UPS)

(*) Spain only (**) Rest of World

700 / 490 1000 / 700 1500 / 1050 2000 / 1400 3000 / 2100 4000 / 2800 5000 / 3500 6000 / 4200

450 x 483 x 87 (2U) 450 x 483 x 87 (2U) 450 x 483 x 87 (2U) (x 2) 450 x 483 x 87 (2U) (x 2) 450 x 483 x 87 (2U) (x 2) 600 x 483 x 132 (3U) (x 2) 600 x 483 x 132 (3U) (x 2) 600 x 483 x 132 (3U) (x 2)

16 17 10 + 28 11 + 28 12 + 28 14 + 64 14,5 + 64 15 + 64

WARRANTY

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SLC CUBE3

UNINTERRUPTIBLE POWER SUPPLY FROM 7,5 TO 80 kVA SLC CUBE3 : The most versatile solution in electrical protection

SALICRU, always faithful and committed to technological developments, has gone one step further and conceived a unit which, by bringing in state-of-the-art PWM-transformerless technology, can easily adapt to the most diverse and complicated loads, such as the non-linear systems (IT systems), strongly inductive or capacitive loads, discharge lamps, induction motors, , and gives numerous benets at the same time, such as: improving reliability and tolerance to failure, being totally exible and adaptable to any working environment, giving greater security to the supplied loads, extending the life span of the batteries, enhancing considerable savings in consumed energy, in operating costs and temperature control needs, and being more respectful of the environment. The SLC CUBE3 range, conceived with criteria of maximum efciency and energy savings, covers power ratings from 7.5 to 80 kVA in a highly compact format making it easy to install and uses more than 60% recyclable materials. For highly critical installations or others in need of growth, the units can also be set up in parallel-redundant systems without any need for additional hardware, and each unit also has a wide range of communication possibilities and a large variety of options.

PERFORMANCES
On-line double conversion technology with DSP (Digital Signal Processor) control. Efciency up to 95%. Adaptive Feed forward Cancellation advanced control. Very low input current distortion (THDi up to < 1%). Unity input power factor (PF=1.0). Control designed to withstand any kind of load. Parallel/redundant set-up up to 8 units. Eco-Mode function to increase energy savings. Batt-Watch battery monitoring and care. Calculation of the back-up available for lengthy power cuts. Space-saving compact format. Wide control and monitoring options. Total exibility in single phase / three-phase input set-ups. Large variety of options available. Materials over 60% recyclable. SLC Greenergy solution.

SLC CUBE3 equipment

SLC CUBE3 display

APPLICATIONS: The best protection for critical systems


The great exibility and adaptability of the SALICRU SLC CUBE3 series make it the best option for protection and security for a wide range of installations: data centres (computing centres, centralised sales/distribution systems, hosting, housing,), IT-networks (server farms, local computer networks, network switches and hubs,), nancial services (bank ofces, automatic cash dispensers, card payment authorisation systems,), industrial processes (productive and control systems, industrial machinery, emergency and lighting systems,), telecommunications (voice and data networks, radio and TV systems, repeater stations,) and infrastructures (hospitals, airports, tunnels,).

UNINTERRUPTIBLE POWER SUPPLIES (UPS)

SLC CUBE3
BENEFITS
High power factor (FP=1.0)
INPUT POWER FACTOR
1,20 1,00 0,80

UNINTERRUPTIBLE POWER SUPPLIES FROM 7,5 TO 80 kVA


TECHNICAL CHARACTERISTICS
MODEL
TECHNOLOGY INPUT
Nominal voltage Voltage margin Frequency Total harmonic distortion (THDi) Power factor 7,5 20 kVA 30 80 kVA

SLC CUBE 3
On-line, double conversion, HF, DSP control Single phase 220 / 230 / 240 V Three-phase 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N) +15% / -20 % (@ 3x400 V / 230 V Ph-N) 50 / 60 Hz 100% load: <1.5% / 50% load: <2.5% / 10% load: <6.0% 100% load: <1.0% / 50% load: <2.0% / 10% load: <5.0% >0.99 (above 10% load) Single phase 220 / 230 / 240 V Three-phase 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N) Steady state Dynamic state Frequency Synchronised Free running Max. synchronisation speed Total harmonic distortion (THDi) Admissible overload Admissible crest factor Admissible power factor Linerar load Non-linear load 1% 2% (load variations 100% - 0% - 100%) 50 / 60 Hz 4% 50 / 60 Hz 0.05% From 1 Hz/s to 10 Hz/s (programmable) <0.5% <1.5% (EN-62040-3) 125% for 10 min. / 150% for 60 s. 3.4:1 (7.520 kVA) / 3.2:1 (3060 kVA) / 2.8:1 (80 kVA) 0.5 inductive to 0.5 capacitive (Totally capacitive or totally inductive in a single phase) 92.0% 95.0% Solid state, microprocessor controlled Single phase 220 / 230 / 240 V Three-phase 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N) 50 / 60 Hz Nil Immediate for overloads of over 150% Automatic after alarm disappearance Without interruption Single phase 220 / 230 / 240 V Three-phase 3 x 380 / 3 x 400 / 3 x 415 V (3Ph + N) 50 / 60 Hz Three-phase IGBT complete wave, soft start and PFC Against transitory over-voltages Acid lead, sealed, maintenance free 4 hours to 80% of capacity Against over-voltages and under-voltages Batt-Watch RS-232 / 485 AC failure, by-pass, low battery 0 C +40 C Up to 95% non-condensing 2,400 m.a.s.l. <52 dB (1) EN-62040-1-2; EN-60950-1 EN-62040-2 VFI-SS-111 according to EN-62040-3 CE ISO 9001 and ISO 14001 TV
Data liable to changes without prior notice

FPin

0,60 0,40 0,20 0,00 0% 25% 50% 75% 100%

LOAD

High output (>95%)


SERIES TIPICAL EFFICIENCY

OUTPUT

Nominal voltage Precision

100%

75%

EFFICIENCY

50%

25%

0% 0% 25% 50% 75% 100%

LOAD

COMMUNICATIONS
Interface to relays. RS-232/485 port. 1 x free slot. MODBUS/SEC protocol. 2 x connectors for parallel connection.

Efciency

STATIC BYPASS

Type and activation criteria Voltage Frequency Transfer time Transfer to by-pass Retransfer

MANUAL BYPASS Type


Voltage

OPTIONS
Extended autonomies. Separator transformer. SICRES adapter for remote telemanagement. WEB/SNMP or GPRS adapter. Monitoring and management software. Shutdown software. 1 x additional RS-232/485 serial port. Temperature and humidity sensors. External display. External manual Bypass. Frequency converter function. BACSII, monitoring, regulation and alarms for batteries.

Frequency

RECTIFIER BATTERIES

Structure Protection Type Recharging time Protection Charge voltage regulation

COMMUNICATION Ports
Interface to relays

GENERALS

Operating temperature Relative humidity Operating altitude Acoustic noise at 1 metre

STANDARDS

Safety Electromagnetic Compatibility (CEM) Operating Marking Quality and Environmental Management

(1) < 65 dB for the 80 kVA model

SERVICE & technical support


Advisory service before and after the sale. Start up. Telephone technical support. Preventive / corrective interventions. Maintenance contracts. Tele-maintenance contracts (SICRES). Training courses.

RANGE
MODEL
SLC-7,5-CUBE3 SLC-10-CUBE3 SLC-15-CUBE3 SLC-20-CUBE3 SLC-30-CUBE3 SLC-40-CUBE3 SLC-50-CUBE3 SLC-60-CUBE3 SLC-80-CUBE3

POWER CABINETS No. UPS DIMENSIONS WEIGHT


(kVA / kW) 7,5 / 6 10 / 8 15 / 12 20 / 16 30 / 24 40 / 32 50 / 40 60 / 48 80 / 64 (UPS + BAT) 1+1+1+1+1+1+1+1 1+1 1+1 (D x W x H mm.) 700 x 450 x 1100 700 x 450 x 1100 700 x 450 x 1100 700 x 450 x 1100 805 x 590 x 1320 805 x 590 x 1320 805 x 590 x 1320 805 x 590 x 1320 805 x 590 x 1320 (Kg) 246 248 250 252 469 573 200 200 300

BAT DIMENSIONS WEIGHT


(D x W x H mm.) 980 x 650 x 1320 980 x 650 x 1320 980 x 650 x 1320 (Kg) 710 710 1020

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM763A01 CODE 401AB000562 ED. JANUARY 2011 UNINTERRUPTIBLE POWER SUPPLIES (UPS)

(*) Spain only (**) Rest of World

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SLC ELITE / SLC ELITE MAX


UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FROM 60 TO 300 kVA SLC ELITE / SLC ELITE MAX: New solutions in high performance protection
The SLC ELITE and SLC ELITE MAX series On-line double conversion with THF (Transformerless High Frequency) technology, in a power range between 60 and 300 kVAs, are at the top of the SALICRU UPS range and are a further step in protecting and supplying high output three-phase power supply. The premises in designing these series were to have an end product that gathered the maximum performance with regard to exibility, operability, reliability and the lowest possible operating cost, amply achieved thanks to its characteristics of modularity, parallel capacity, tolerance to failure, high output, easy operation and adaptability to the different working environments. All of this makes them the ideal protection system for computer environments, telecommunications and critical process systems and infrastructures.

SLC ELITE model

PERFORMANCES
On-line double conversion with PLD control. Walk-in or soft start rectier. Input power factor > 0.95. Growth in parallel up to 8 units (standard parallel kit). Ring topology in redundant congurations. THF technology inverter in all models. Batt-Watch control of the batteries for fast charging, surveillance and extreme care. AGM batteries with a life span of 10 years, standard. Static and maintenance bypass in all equipment, standard. User interface by alphanumerical display programmable in several languages. Fluid-Cooling heat dissipation system. (1) Operation selectable inverter / EcoMode. THDi < 5%, with harmonicless. The best ratio between power/occupied surface. FP admissible up to 0.8 both with inductive and capacitive loads.
SLC ELITE MAX model

APPLICATIONS: Ideal for all environments


Data centre: Data are currently the most powerful value in business, making the hourly cost of network downtime astronomical applications servers, communication servers, data storage bases, active network elements, etc.. Telecommunications: The telecommunications era brings forth the need to avoid failures in supply that could cut off the communication between subscribers internet centres, land line telephony infrastructure, mobile switching centre, radio/television broadcasters, etc.. Industrial processes: Electrically complicated environments, contaminated environments and special mechanical requirements are some of the industrial work scenarios where the purpose is to supply safe energy in difcult environments continuous critical processes, monitoring, instrumentation, security systems, etc..

(1) SLC ELITE MAX models

UNINTERRUPTIBLE POWER SUPPLY (UPS)

SLC ELITE SLC ELITE MAX


PARALLEL architecture
To reply to larger requests for availability and the need for growth and evolution in the installations, the SLC ELITE and SLC ELITE MAX series allow for the parallel operation of up to 8 units.

UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FROM 60 TO 300 KVA


TECHNICAL SPECIFICATIONS
MODEL
TECHNOLOGY INPUT
Voltage Voltage range Frequency range Rectier Total harmonic distortion (THDi) Power factor > 0.99 (2) 3 x 380 / 400 / 415 V Steady state Dynamic state with load steps Frequency Maximum slew rate Efciency Total harmonic distortion (THDv) Dynamic response time Permissible overload 125% 150% 5 seconds Nil 3 x 380 / 400 / 415 V 50 / 60 Hz Automatic after alarm disappearance 1000% for 100 ms Immediate for overloads higher than 150% Manual 3 x 380 / 400 / 415 V 50 / 60 Hz Pb-Ca, maintenance free, gas recombination From end of autonomy till 80% of the capacity, 4 hours Batt-Watch 0 C + 40 C Up to 95%, non-condensing 2400 m.a.s.l. EN-62040-1-2 / EN-60950-1 EN-62040-2 VFI segn EN-62040-3 CE ISO 9001 and ISO 14001 TV
Data liable to changes without prior notice.
(*) Spain only (**) Rest of World

SLC ELITE

SLC ELITE MAX

On-line, double conversion, PLD control

3 x 380 / 400 / 415 V 3 x 330 480 V 3 x 320 480 V 40 70 Hz Walk-in type < 5% (2) > 0.96 1% 4% 50% 0.005% 1 Hz / s > 92% < 2% 50 ms 10 minutes Immediate Solid state, PLD control > 95% 5% 100% 0.0001%

OUTPUT

Voltage Accuracy

Synchronised Free running

Selectable 1%, 2%, 5% and 10%

Ring topology

FLUID-COOLING
Innovative heat dissipation system consisting of circulating high output transport uid.

STATIC BYPASS

Type and activation criteria Transfer time Voltage Frequency Re-transference Permissible overload Transfer to Bypass

MANUAL BYPASS BATTERIES

Transfer type Voltage Frequency Type Recharge time Protection Charge voltage control

Against overvoltage, undervoltage and alternating current

GENERALS

Operating temperature Relative humidity Maximum operating altitude Safety Electromagnetic Compatibility (EMC) Operating Marking Quality and Environmental management

STANDARDS

(2) Harmonicless solution

Fluid-Cooling system

COMMUNICATIONS
RS-232, AS-400 and relay interfaces standard. Monitoring and le closing software.(1) Remote control.(1) SNMP adapter.(1) SICRES telemanagement software.(1) MODBUS protocol.(1) RS-485 protocol.(1) 2nd RS-232 port.(1)

SLC ELITE RANGE


MODEL
SLC-60-EL SLC-80-EL SLC-100-EL SLC-120-EL

POWER
(kVA / kW)

Nr. UPS + BAT CABINETS


1+1 1+1 1+1 1+1

UPS DIMENSIONS
(D x W x H mm)

WEIGHT
(Kg)(3)

BAT DIMENSIONS
(D x W x H mm)

WEIGHT
(Kg) (3)

60 / 48 80 / 64 100 / 80 120 / 100

730 x 710 x 1800 730 x 710 x 1800 730 x 710 x 1800 730 x 710 x 1800

295 330 370 450

830 x 790 x 1800 830 x 790 x 1800 830 x 790 x 1800 830 x 790 x 1800

547 726 726 870

SLC ELITE MAX RANGE


MODEL
SLC-160-ELM SLC-200-ELM SLC-250-ELM SLC-300-ELM

POWER
(kVA / kW)

Nr. UPS + BAT CABINETS


1+1 1+1 1+1 1+1

UPS DIMENSIONS WEIGHT


(D x W x H mm.) (Kg)(3)

BAT DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg) (3)

TOTAL availability
Harmonicless solutions.(1) Extended autonomies.(1) External manual bypass.(1) Galvanic isolation in the bypass line.(1) Non-standard frequencies and voltages.(1) Independent bypass and rectier inputs.(1)
(1) Option

160 / 128 200 / 160 250 / 200 300 / 240

800 x 1240 x 1800 800 x 1240 x 1800 800 x 1240 x 1800 800 x 1240 x 1800

570 600 630 630

830 x 790 x 1800 830 x 1400 x 1800 830 x 1400 x 1800 830 x 1400 x 1800

1190 1640 1640 1776

(3) Estimated autonomy between 4 and 8 minutes, with 3 x 400 V input / output voltages. For other congurations, dimensions and weights consult.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM583A01 CODE 401AB000353 ED. JANUARY 2011 UNINTERRUPTIBLE POWER SUPPLY (UPS)

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

OPTIMUS

COMPACT DC POWER SYSTEMS OPTIMUS: Compact DC Power Systems for Telecommunications

The DC Power Systems SALICRU OPTIMUS series are rectiers especially designed for supplying small and medium power telecommunications equipment. Produced in versions of 300 and 700 W per module, they can be congured both in the number of rectiers and battery breakers or distribution in order to adapt to the most varied power supply requirements. They are conceived to be included in 19 racks or ETSI, and 2 sub-racks can be connected in parallel in applications with larger power demands. The main sub-rack, in its maximum conguration, has 3 plug-in type rectiers, monitoring and control unit. MS-100 current distribution unit with capacity for up to 8 breakers of different calibres, alarm card and 2 breakers for connecting 2 sets of batteries. All of the system values and parameters, and the alarm category, may be modied by an LCD display or software for PC (optional).

Optimus 300 W

Optimus 700 W

PERFORMANCES
Suitable for single phase or three-phase supplies. Great power density. Easy installation and maintenance. High MTBF. High efciency. Low cost operation and maintenance. Battery charging current limitation. Plug-in type output distribution unit (8 breakers). Plug-in type battery unit (2 breakers). Suitable for connecting any type of battery. Front input/output and connectors. Alarm card. Breaker calibre up to 30 A (Optimus 300) or 60 A (Optimus 700). Modularity: up to 3 plug-in type rectiers per sub-rack. Power factor close to the unit.

LCD panel

MS-100 control

Supply and alarm unit. Optimus 700 W.

APPLICATIONS: Telecommunications systems always operative


The SALICRU OPTIMUS DC Power Systems provide high level supply to the always critical telecommunications systems, guaranteeing their perfect operation without unexpected cuts. Due to their modular nature, they can also be expanded according to needs, thus optimising the investment.

DC POWER SYSTEMS

OPTIMUS
UNIT connectivity
1. RJ-45 connector optional for LCD display or PC. 2. 10 plug and play type connections (8 for output distribution and 2 for batteries). 3. AC power supply connectors. 4. Urgent alarm outputs, Not urgent and informative. 5. Alarm outputs trigger distribution magnetic thermal and trigger battery magnetic thermal. 6. Temperature probe. 7. Reading of maximum/minimum input voltage. 8. RS-232 and RS-485 ports. 9. Outputs 1 to 8. 10. Battery connectors.

COMPACT DC POWER SYSTEMS

TECHNICAL SPECIFICATIONS
MODEL
INPUT
AC voltage Voltage range Power factor Nominal current Maximum current Efciency Frequency Protection > 0.86 1.43 A 2.09 A 50 / 60 Hz Input fuse 10 A and overtemperature - 48 V - 48 V - 60 V 0.1% (with battery full charged) 300 W 900 W 5.5 A Output fuse 25 A 50 mVpp Active Power Factor Correction (PFC) Against 5 kV transients (8 / 20 impulses s) 1500 Vac, 1 minute, input 800 Vac, 1 minute, output IP20 > 10 M < 2 mV < 40 dB Natural - 10 C a + 45 C - 20 C a + 70 C Up to 95%, non-condensing 2400 m.a.s.l. 250,000 hours On / Rectier fault On, Alarm, Alarm A1, Alarm A2, End of autonomy, Alarm 01, TX, RX RS-485 or RS-232 through RJ45 connector MODBUS, as standard EN 60950-1 ETS 300386-2 CE ISO 9001 and ISO 14001 TV
Data may change without previous notice. (*) Spain only (**) Rest of World

OPTIMUS 300
230 V 15%

OPTIMUS 700
> 0.95 3.55 A 6.41 A

> 85% (50% to 100% of the load) > 90% (10% to 100% of the load)

OUTPUT

DC voltage Volatge adjustment Accurancy Nominal power Maximum subrack power Nominal current (per module) Response time Protection Maximum ripple Single or three phase Protection Dielectric strenght Protection degree in a/ with standards Isolation Pshophometric noise Acoustic noise at 1 metre Cooling Operating temperature

700 W 2100 W 13 A

0.1% (10% a 100% load steps)

STRUCTURE GENERALS

Optimus 300 W

Storage temperature Relative humidity Maximum operating altitude Mean Time Between Failures (MTBF) Mean Time To repair (MTTR) Optical module indicators INDICATORS & COMMUNICATION Optical control MS-100 indicators Communication ports

15 minutes

STANDARDS

Protocol Safety Electromagnetic Compatibility (CEM) Marking Quality and Environmental management

RANGE
Optimus 700 W

MODULE
OPTIMUS 300 OPTIMUS 700
(1) Complete subrack

POWER / MODULE
(W)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg) (1)

300 700

260 x 483 x 133 260 x 483 x 267

13 17

OPTIONS
LCD display. Monitoring software for Windows. RS-485 to TCP-IP converter.

COMMUNICATIONS & services


MS-100 Monitoring and Control Unit. RS-232 and RS-485 serial ports. Pre-sale and after-sale advisory service. Multiple formulae for maintenance and telemaintenance (SICRES).

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM585A01 CODE 401AB000366 ED. JANUARY 2011 DC POWER SYSTEMS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

FAC P

DC POWER SYSTEMS FAC P: DC Power Systems for medium and high powers

The SALICRU FAC P series DC Power Systems are rectiers especially designed to supply the most varied medium and high power equipment in DC. Made in powers of 1000, 2000, 2700 and 5000 W, they can be connected in parallel and form part of 19 cabinets, where each cabinet can also include the monitoring and control unit (MS-102), batteries and DC output distribution, and a load priority system. Each rectier module is also prepared for hot swapping, with all of the advantages that this involves for the system operation. On the other hand, the large amount of rectier modules that can be connected in a single system will allow a power concentration of over 170 kW. The Monitoring and Control Unit (MS-102) controls the whole system, stores and manages input, output and battery data and all of the parameters are programmed here. Through the RS-485 port, there is communication with the rectier modules, controlling at all times the output voltage, the current spreads between modules, the battery loading current, the control of the priority and non-priority load contactors, the ends of autonomy, etc. Exterior communication may be in local or remote mode (GSM / TCP-IP).

FAC 1000 P FAC 2700 P

FAC 2000 P

PERFORMANCES
Suitable for single phase or three-phase supplies. Great power density. Easy installation and maintenance. Low cost operation and maintenance. High MTBF. High efciency. Battery charging current limitation. Unit power factor. Hot swapping modules. Monitoring and Control Unit (MS-102).

MS-102

APPLICATIONS: DC power systems always available


The SALICRU FAC P series DC Power Systems provide high level supply to the always critical telecommunications systems, guaranteeing their perfect operation without unexpected cuts. Due to their modular nature, they can also be expanded according to needs, thus optimising the investment.

DC POWER SYSTEMS

FAC P
UNIT connectivity
1. 2. 3. 4. 5. 6. 7. 8. Output distribution. Input protection. MS-102. FAC P modules. Slots for increasing power. Battery protection. Batteries. Cable input.

DC POWER SYSTEMS

TECHNICAL SPECIFICATIONS
MODEL
INPUT
Ac voltage Volatge range Power factor Nominal current Maximum current Efciency Frequency Protection 5.0 A 5.9 A > 87% 10.7 A 12.6 A > 82% 50 / 60 Hz Electronic 12, 24, 36, 48, 60, 110, 125, 216, 220 V 48, 110, 125 V - 15% + 25% 0.1% (with charged batteries) 1000 W (2) 2000 W (3) 2700 W 49, 22, 20 A < 1 mV Active parallel Yes (1) Against 5 kV peaks ( 8 / 20 s ) Pb-Ca or Ni-Cd I / U constant 0.1 a 0.3 C adjustable Up to 80% in 4 hours (0.2 C) Against overvoltages and undervoltages 2000 V @ 1 minute IP20 > 20 M < 50 dB Forced Controlled and forced 0 C + 40 C - 20 C + 70 C Up to 95%, non-condensing 2400 m.a.s.l. 100,000 hours Yes Yes Yes Yes NA RS-232 / RS-485 / relays EN 60950-1 EN 61204-3; ETS 300 386-2 CE ISO 9001 e ISO 14001 TV Yes 150,000 hours 15 minutes NA Yes 100,000 hours
Data may change without previous notice. (*) Spain only (**) Rest of World

FAC 1000P FAC 2000P FAC 2700P FAC 5000P


230 V 15% > 0.99 (1) 13.5 A 15.8 A > 90% 24.8 A 29.2 A 230 V or 3 x 400 V

OUTPUT

DC nominal volatge Voltage adjustment range Accurancy Nominal power Nominal current Psophometric noise

12, 24, 36, 48, 60, 110, 125, 216, 220 V

5000 W (3) 181, 181, 121, 91, 72, 40, 36, 20, 20 A < 3 mV

25, 25, 24, 18, 75, 75, 48, 36, 14, 8, 7, 4, 4 A 29, 16, 14, 8, 8 A < 3 mV

STRUCTURE BATTERIES

Load sharing Power factor corrector (PFC) Protection Type Charging curve Charging current Recharging time Protections

GENERALS

Dielectric strenght Protection degree according with the standards Insulation Acoustic noise at 1 metre Cooling Operating temperature Storage temperature (4) Relative humidity Maximum operating altitude Mean Time Between Failures (MTBF) Mean Time To Repair (MTTR)

Forced

INDICATORS

Display LCD General alarm Equipment On

OPTIONS
MS-102 Monitoring and Control Unit. Output distribution. Positive, negative or oating output voltages. Ground failure detector. Any type of battery: Sealed, Ni-Cd, open, etc. Atmospheric discharger. Output voltage reducer. Other IP.

Batteries on discharge / oat COMMUNICATIONS Ports Safety STANDARDS Electromagnetic Compatibility (CEM) Marking Quality and Environmental management
(1) Single phase input only. (2) Except 12 V and 24 V output voltages. (3) Except 12 V output voltage. (4) No batteries.

RANGE
RECTIFIER MODULE
DIMENSIONS (D x H x W mm.)
425 x 483 x 2U 525 x 483 x 3U (5) 450 x 73 x 6U 525 x 483 x 4U

WEIGHT (Kg)
12 15 6 28

COMMUNICATIONS & services


RS-232 and RS-485 serial ports. Relay interface. MODBUS communications protocol. Pre-sale and after-sale advisory service. Multiple formulae for maintenance and telemaintenance.

FAC 1000P FAC 2000P FAC 2700P FAC 5000P


(5) 2U for 48V models.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM581A01 CODE 401AB000392 ED. JANUARY 2011 DC POWER SYSTEMS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

CS-IS

DC POWER CONVERTERS CS IS: High performance DC/AC industrial converters

SALICRUs CS IS series DC/AC converters are based on technically advanced solutions such as PWM technology and digitally controlled servo systems so as to obtain: high performance, low distortion (THDv < 2%) and elevated stability. Moreover, they offer excellent tolerance to short-circuits, polarity inversion protection and the possibility of operating in Eco-mode. The line is available in power ranges between 1000 and 6000 VA, with admissible continuous incoming voltage from 48 Vdc to 220 Vdc nominal input.

PERFORMANCES
Availability in a wide range of voltages and outgoing power. Broad range of input voltage variation. LCD display comes standard. Communication through relay interface or RS-232/RS-485. Excellent dynamic behavior. Automatic restart to re-establish incoming power. Ramp start. 19 rack or box casing.

APPLICATIONS: Energy conversion for industrial plants


SALICRUs CS IS series provides quality AC power from a DC power asuch as cogeneration and biomass plants, gas generators, water distributors, power stations and substations, telecommunications, etc.

TECHNICAL SPECIFICATIONS
MODEL
INPUT OUTPUT
DC nominal voltage Voltage range AC nominal voltage Accuracy Frequency Frequency range Synchronization speed Admissible overload Efciency Synchronized Unsynchronized

CS IS
48 V, 110 V, 120 V, 125 V, 220 V - 17%, + 20% 120 V, 220 V, 230 V, 240 V 2% 50 / 60 Hz 0.1 Hz 9.9 Hz in increments of 0.1 Hz 0.05% 1 Hz/s 150% for 30 seconds / 125% for 45 seconds Up to 92% - 10 C + 40 C Forced Up to 95%, non-condensing 2400 m.a.s.l. EN 60950-1 EN 61000-6-3; EN 61000-6-1 CE ISO 9001 and ISO 14001 TV

GENERALS

Operating temperature Cooling Relative humidity

CS 4000-IS model

Maximum operating altitude

STANDARDS

Safety Electromagnetic Compatibility (EMC) Marking

OPTIONS
Static bypass. EMI lters. Separation transformer on the bypass line. Psofometric lter. Anti-harmonic lter.

Quality and Environmental management

RANGE
MODEL POWER (VA)
CS 1000-IS CS 2000-IS CS 3000-IS CS 4000-IS CS 5000-IS CS 6000-IS
1000 2000 3000 4000 5000 6000

INPUT VOLTAGE
(Vdc) 48 110 120 125 220

DIMENSIONS
(D x W x H mm) BOX
(1)

WEIGHT
(Kg)
(1)

RACK

385 x 440 x 180

385 x 483 x 4U

36 49 57 63 68 84

385 x 440 x 180 (1) 385 x 483 x 4U (1) 385 x 440 x 180 (1) 385 x 483 x 4U (1) 600 x 440 x 270 600 x 440 x 270 725 x 440 x 270 600 x 483 x 6U 600 x 483 x 6U -

SERVICES
Pre-sales and post-sales consultation service. Several maintenance and remote maintenance methods.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM673C01 CODE 401AB000466 ED. JANUARY 2011
STATIC INVERTERS

(*) Spain only (**) Rest of World

Dimensions and weights for models without bypass nor lters. Ask for another power needs and/or congurations. (1) For voltages 110 Vdc.

Data liable to changes without prior notice.

UNIN T ERRUP T IBL E P OW ER SUP P L IES (UP S) + L IGH T ING F LOW DIMMER- S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE C ONDI T IONERS + DC P OW ER S Y S T EMS + S TAT IC IN V ER T ERS + P HO T OVOLTA IC IN V ER T ERS

CS WAVE MDL
48 VDC POWER CONVERTERS CS WAVE MDL: DC/AC converters for telecommunications
Todays telecommunications systems include a large variety of critical loads that must be correctly powered and protected. SALICRUs CS WAVE MDL is based on the modular architecture that can be adapted to any growth and/or redundancy needs. The maximum congurations allows up to 24 kVA in models with 1 or 1.5 kVA, which are supplemented by the modules: static bypass (STS), LCD display, communications and/or manual bypass with distribution

PERFORMANCES
DSP Design (Digital Signal Processor). Back-feed protection standard (in congurations with STS). All Master technology for better reliability. Senoidal output. Hot-Swap. High density power. Polarity inversion protection. Smart ventilation control.

APPLICATIONS: AC power for Telecom systems


Normally for mobile or land-line telecommunications systems not able to connect to the mains, that need autonomous solutions providing power from back-up elements (batteries, fuel-cell,...).

TECHNICAL SPECIFICATIONS
MODEL
INVERTER
Technology Modular power Maximum no. models x system Input voltage Output voltage Output frequency Psofometric noise Efciency Admissible overload

CS WAVE MDL
DSP; All Master 1000 VA / 800 W and 1500 VA / 1200 W 15 x 1500 VA or 24 x 1000 VA 40.5 Vdc 58 Vdc 230 Vac 50 / 60 Hz # 1 mV > 89% 150% for 20 seconds 12 kVA < 5 ms Input / Output / Alarms / General RS-232, RS-485, USB and free contacts CANBUS 2 x 20 A + 1 x 32 A + 1 x 50 A Combined Inverter - STS - Manual bypass EN 60950-1 EN 61000-6-3; EN 61000-6-1 CE ISO 9001 and ISO 14001 TV
Data liable to changes without prior notice.
(*) Spain only (**) Rest of World

STATIC BYPASS (STS) LCD DISPLAY INTERFACE MANUAL BYPASS


CS WAVE MDL model

Power Transfer time Synchronism Settings Ports Protocol Distribution 5 position selector Safety Electromagnetic Compatibility (EMC) Marking Quality and Environmental management

2.5%

STANDARDS

OPTIONS
Static bypass up to 12 kVA. LCD display. Communications interface. Manual bypass with distribution.

RANGE
MODEL
CS 1000-WAVE MDL 48/230 CS 1500-WAVE MDL 48/230 STS-WAVE MDL LCD-WAVE MDL COM-WAVE MDL BM+DIS-WAVE MDL

DESCRIPTION
Inverter 1000 VA Inverter 1500 VA Static bypass (STS) Display LCD Communications Manual bypass + distribution

DIMENSIONS
(D x W x H mm)

WEIGHT
(Kg)

270 x 215 x 1U 270 x 215 x 1U 270 x 215 x 1U 270 x 90 x 1U 270 x 180 x 1U 270 x 483 x 2U

2.5 3 3 1 0.5 4

SERVICES
Pre-sales and post-sales consultation service. Several maintenance and remote maintenance methods.

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM673C01 CODE 401AB000466 ED. JANUARY 2011
STATIC INVERTERS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

RE

ELECTRONIC VOLTAGE STABILISERS RE: The fastest and the most accurate electronic regulation system of the market

In todays electronic environment, saturated and highly unstable, where uctuations in the power supply voltage are more than frequent, voltage stabilisers play a very important role in guaranteeing stable voltage to loads more sensitive to such variations. The SALICRU RE series of electronic stabilisers, based on a completely static structure of high efciency, fast reply speed and excellent output precision, are made in single phase or three-phase conguration and in a range of powers from 300 VA to 150 kVA. The three-phase units are conceived with a completely phase-independent regulation in order to avoid possible regulation problems due to imbalance in the loads. Moreover, the units include a static bypass (1) to guarantee the power supply in the event of a possible fault.

PERFORMANCES
Ultra-fast regulation: reply speed under 100 ms. Control and test of all parameters by one microprocessor per phase. Entirely static structure, without moving elements, greater reliability. Static bypass (1), loads always supplied. In three-phase units, independent regulation per phase, immune to imbalances. Output precision better than 2%. 15% input regulation margins standard. Efciency > 97%. Voltmeter standard above 6 kVA-threephase or 15 kVA-single phase. Voltmeter switch standard in three-phase units. Separator transformer or ultra-isolation on unit output. (2) Relay interface. (2) Maximum and minimum voltage protections. (2)

RE unit

APPLICATIONS: Assured industrial processes


Many are the industrial processes where voltage stability is essential: from a wide range of applications where the numerical control processors and automatons are entrusted with guaranteeing the nal result, up to all kinds of calculation centres, computer peripherals, transmission and communications equipment, laboratory equipment, etc.

(1) Models 1 kVA (2) Optional

VOLTAGE STABILISERS

RE
DESCRIPTION
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Output voltmeter. Voltmeter switch (three-phase units). Synoptic. Start / Stop switch. Transient protection. Input terminals. Output terminals. Ventilation grilles. Cable input / output. General input magnetic thermal switch.

ELECTRONIC VOLTAGE STABILISERS

TECHNICAL SPECIFICATIONS
MODEL
INPUT
Single phase voltage Three phase voltage Regulation range Frequency Power Factor

RE
120 V, 220 V, 230 V, 240 V 3 x 208 V, 3 x 220 V, 3 x 380 V, 3 x 400 V, 3 x 415 V 15% (1) 48 63 Hz > 0.95 120 V, 220 V, 230 V, 240 V 3 x 208 V, 3 x 220 V, 3 x 380 V, 3 x 400 V, 3 x 415 V Better than 2% 48 63 Hz Nil 100 ms > 97% 200% for 1 minute Static (2) - 10 C + 45 C Up to 95%, non-condensing 2400 m.a.s.l. 30 minutes < 35 dB Natural or forced depending on power rate With isolation transformer > 40 dB With ultra-isolation transformer > 120 dB EN 60950-1 EN 61000-6-3; EN 61000-6-2 CE ISO 9001 and ISO 14001 TV
(2) Standard from 1 kVA and above Data liable to changes without prior notice.
(*) Spain only (**) Rest of World

OUTPUT

Single phase voltage Three phase voltage Accuracy Frequency Harmonic distortion Response time Efciency Permissible overload Type Ambient operating temperature Relative humidity Maximum operating altitude Mean Time Between Failures (MTBF) Mean Time To Repair (MTTR) Acoustic noise level at 1 metre Cooling Electrical noise attenuation on common mode

BYPASS GENERALS

60,000 hours

STANDARDS

Safety Electromagnetic Compatibility (EMC) Marking Quality and Environmental management

Exterior view of RE unit

(1) Other ranges under request

RANGE(3)
MODEL
RE-309-2 RE-609-2 RE-1009-2 RE-2009-2 RE-3009-2 RE-4509-2 RE-6009-2 RE-9009-2 RE-12009-2 RE-15009-2 RE-20009-2 RE-25009-2 RE-30009-2 RE-40009-2 RE-50009-2
Connection view of the RE unit

POWER
(kVA / kW)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

0.3 0.6 1 2 3 4.5 6 9 12 15 20 25 30 40 50

280 x 210 x 185 280 x 210 x 185 280 x 210 x 185 390 x 250 x 195 390 x 250 x 195 460 x 300 x 220 570 x 317 x 237 570 x 317 x 237 680 x 340 x 240 680 x 340 x 240 740 x 350 x 675 740 x 350 x 675 740 x 350 x 675 740 x 350 x 675 740 x 350 x 675

6 6 9 19 22 35 44 58 67 69 103 127 154 170 186

Nomenclature, dimensions and weight for models: 230 V 50 Hz input / 230 V 50 Hz output and 15% input range

OPTIONS available
Relay interface. Manual maintenance bypass. Maximum-minimum voltage protections with manual or automatic reset. Output magnetic thermal protection. Gas discharger. Input/output ammeter. Separator transformer (T). Ultra-isolation transformer (NS).

MODEL
RET 3-4 RET 6-4 RET 9-4 RET 15-4 RET 20-4 RET 30-4 RET 45-4 RET 60-4 RET 75-4 RET 100-4 RET 125-4 RET 150-4 RET 200-4 RET 250-4

POWER
(kVA / kW)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

SERVICES
Pre-sale and after-sale advisory service. Multiple formulae of maintenance and telemaintenance.

3 6 9 15 20 30 45 60 75 100 125 150 200 250

680 x 340 x 240 680 x 340 x 240 630 x 390 x 520 725 x 350 x 625 725 x 350 x 625 725 x 350 x 625 725 x 350 x 625 925 x 425 x 640 925 X 425 X 640 838 x 616 x 1318 838 x 616 x 1318 838 x 616 x 1318 810 x 640 x 1530 810 x 640 x 1530

32 61 68 80 117 164 225 260 317 343 438 650 850 925

Nomenclature, dimensions and weight for models: 3 x 400 V 50 Hz input / 3 x 400 V 50 Hz output and 15% input range (3) For models with isolation transformer and other congurations, consult

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM600C01 CODE 401AB000390 ED. JANUARY 2011 VOLTAGE STABILISERS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

EMi2

SERVOMOTOR VOLTAGE STABILISER EMi2: A great classic update

Servomotor voltage stabilisers do have accumulated great experience, for they plenty years service in all of those appliances which a perfect voltage supply stabilisation is a must within complex critical loads: high start-up inrush currents, strongly reactive power behaviour, great power, etc. Notwithstanding and because of it, instead of disuse positioning, they do still enjoy prestige given to all dutyful industry appliances. Therefore SALICRU, faithful to its duty with quality electric supply, has chosen to review plus update such long lasting equipments. EMi2, as true afore series descending, keeping up high current handling capacity, a great stoutness for lasting overvoltages plus output voltag high accuracy (up to 1%), overall forwarding a new facement, more compact and up to date. As improvements related to aforesaid range, they do have, series-built with toroidal self-transformers use for all power range, leading to a better performance plus response speed, having maintenance bypass and independent regulation per phase.

PERFORMANCES
Toroidal self-transformers for all power range, faster plus more efcient. Independent phase regulation as standard. Manual bypass as standard. Input regulation margins 15% as standard (25% on demand). Output accuracy better than 1% (adjustable). Greater performance, up to 97%. High speed regulation, up to 80 V/sec. Control synoptic phase-independent with 7 segment display. Output digital amperimetre applyable within display. (1) Output voltage max-min protection. (1) Output stability guaranteed via thyristors servo-control. Relay interface. Null harmonic distortion. Simplied mechanical system, simpler maintenance. Overload tolerance up to 1000% nominal. Great reliability (great MTBF). Wide power range. Silent running.
(1) Optional

EMi2 models

Display for EMi2

APPLIANCES: Difcult loads always under control


Within a great industrial process variety high sensitive voltage variation machinery is employed. Such loads, power-going and strongly reactive-wise, need to be supplied by voltage regulators able to meet such demands. Among others, we could name: milling cutters, grinders, machine-presses, lathes, polishers, electrical discharge machines, etc. as well as gearing and electric manouvering, numercial controls, electric ovens or telecom repeaters.

VOLTAGE STABILISERS & POWER LINE CONDITIONERS

EMi2
CONNECTIVITY
1. Phase synoptic. 2. Manouver switch Line-O-Regulator. 3. R,S,T, input terminals (terminals + protections). 4. U,V,W output terminals (terminals + protections). 5. Variacs magnetothermic protection. 6. I/O neutral terminals. 7. Ground terminal.

SERVOMOTOR VOLTAGE STABILISER

TECHNICAL SPECIFICATIONS
MODEL
INPUT
Voltage Input margin Frequency Power factor Normal (standard) Extended (optional)

EMi2
Single phase 220 / 230 / 240 V, Three-phase 3x380 / 400 / 415 V 15% 25% 48 63 Hz > 0.99 Single phase 230 V, three-phase 3x400 V 1% Adjustable between 200 - 240 Vac 48 63 Hz 2-15kVA single / 6-45kVA three >15kVA single / >45kVA three Efciency Power factor Crest factor Harmonic distortion Independent phase regulation Manual bypass Front panel 80 V/sec. 40 V/sec. > 96% > 0.99 3a1 Null As standard in three-phase models As standard Input/Output voltage, output current (optional), output frequency. Indicators on: operation stabiliser, high/low output voltage True output / operating stabilise (NO, C, NC); High / low output voltage warning (NO, C, NC) < 45 dB (A) - 5C + 55C - 30C + 70C Up to 95%, non-condensing 2400 m.a.s.l. 60,000 hours 30 minutes EN 61000-6-4; EN 61000-6-2 IEC 60950-1; IEC 61558-1 CE ISO-9001 and ISO-14001 TV
Data may change without previous notice. (*) Spain only (**) Rest of World

OUTPUT

Voltage Accuracy (1) Disconnect voltage value (2) Frequency Regulation speed

BYPASS INDICATIONS

Relay interface

GENERAL

Acoustic noise level at 1 metre Working temperature Storage temperature Relative humidity Maximum altitude Mean time between failures (MTBF) Mean time to repair (MTTR)

STANDARDS

Electromagnetic compatibility (EMC) Safety Marking Quality and Environmental management

(1) Adjustable on demand

(2) Optional

MAXIMUM speed
V/s 80

RANGE
MODEL
EMi2 M 5-2BM EMi2 M 7,5-2BM EMi2 M 10-2BM EMi2 M 15-2BM EMi2 M 20-2BM EMi2 M 25-2BM EMi2 M 30-2BM

POWER
(kVA)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

5 7.5 10 15 20 25 30

367 x 508 x 356 367 x 508 x 356 423 x 538 x 418 593 x 365 x 716 693 x 495 x 815 693 x 495 x 815 693 x 495 x 815

42 50 58 120 127 132 138

40

Lexicon, dimensions and weights for models: 3 x 400 V 50 Hz input / 3 x 400 V 50 Hz outpout and 15% entry margins.

SALICRUs EMi2 Regulation speed comparison

Other

MODEL
EMi2 T 15-4FBM EMi2 T 20-4FBM EMi2 T 30-4FBM EMi2 T 45-4FBM EMi2 T 60-4FBM EMi2 T 75-4FBM EMi2 T 90-4FBM EMi2 T 110-4FBM EMi2 T 140-4FBM EMi2 T 160-4FBM EMi2 T 220-4FBM EMi2 T 275-4FBM EMi2 T 330-4FBM

POWER
(kVA)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

15 20 30 45 60 75 90 110 140 160 220 275 330

645 x 445 x 1066 645 x 445 x 1066 645 x 445 x 1066 645 x 445 x 1066 1002 x 548 x 1329 1002 x 548 x 1329 1002 x 548 x 1329 1082 x 616 x 1529 1082 x 616 x 1529 1731 x 887 x 1432 1731 x 887 x 1432 1731 x 887 x 1432 1736 x 887 x 1728

190 206 248 270 360 420 550 624 750 875 1000 1200 1500

AVAILABLE options
Output voltage max-min protection with manual or automatic reload. Output amperimetre. 25% regulation margins.

SERVICES
Pre-Sales & After-Sales assessment service. Maintenance plus telemaintenance several formulae.

Lexicon, dimensions and weights for models: 3 x 400 V 50 Hz input / 3 x 400 V 50 Hz output, independent phase regulation and 15% entry margins.

WWW.SALICRU.COM
REF. JM721A01 CODE 401B000532

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


ED. JANUARY 2011 VOLTAGE STABILISERS & POWER LINE CONDITIONERS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

ILUEST+

LIGHTING FLOW DIMMER-STABILISERS ILUEST+: Regulation + Control = Saving

The days of employing simple voltage dimmers or dual-level voltage regulation to decrease lighting consumption, methods which were perfectly valid before, are long over. Today, it is not sufcient just to stabilise and dim the voltage power supply to lightings to bring about important energy savings. Through the use of advanced technology available, the various lighting equipment installed can be remotely monitored, measured and quantied, thus enabling the sustainability of the lighting installation. The ILUEST+ series of advanced lighting ow dimmer stabilisers from SALICRU, takes over from its highly successful and eld-tested predecessor, has vast improvements in critical aspects of modularity, power density, protection and telemanagement. As a result, greater exibility in areas of power growth, maintenance, commissioning and equipment integration can be better realized along with superior reliability and shorter payback periods. The ILUEST+ series is available in a wide range of powers, has 3 implementation variants - indoor, outdoor and OEM Kit - and 2 monitoring versions. Used in conjunction with our powerful telemanagement SICRES technology, the ILUEST+ is now the state-of-the-art reference in lighting regulation and control.

PERFORMANCES
Bi-directional Buck converter with IGBTs, electronic, static and transformerless. Continuous regulation of the output voltage, no voltage steps; higher lamp lifetime. Lineal and programming ramps. High response time. Stabilisation better than 1% + saving voltage periods = savings > 40%. Protections with automatic programming rearm due to overload and overtemperature. Protections with fuses (1) and against lightning arrestors. (2) Automatic bypass per phase, independent operating, manual operating (3), active by default and make before break. RS-232 and RS-485 ports + MODBUS protocol, as standard. SICRES telemanagement card built in completely. (4) Duty cycle adapted to the warm up curve of the lamp. Programming of two saving levels and start voltage via software. (4) Average payback of the investment between 6 and 24 months. Low weight and dimensions, higher power density. No harmonic injection to mains.

ILUEST+ model

ILUEST+ module

APPLICATIONS: Better management of lightings


The ILUEST+ is suitable for use in many areas, both industrial and commercial e.g. roads and highways, road bridges & tunnels, airports, hospitals, commercial centres, ports, railroads, car parks and many more. The superior supervisory and remote control capability of the ILUEST+ will result in the better and more efcient management of lightings, regardless of their applications. As an example, our studies have shown that a town of 10,000 inhabitants with 1700 public lighting points would consume an average of 1,210 MW of electricity per year. By using just 13 units of the ILUEST+ rated 30 KVA each, potential annual savings of 490 MW can be realized, translated to 270 Tm less CO2 to the atmosphere.
(1) In the equipment. (2) MOV (Metal Oxid Vasistor). (3) Through stated input or keypad. (4) In COM version.

LIGHTING FLOW DIMMER STABILISER

ILUEST+
MONITORING
LCD version: Stabiliser equipment with LCD synoptic for local communication. Based on: LCD panel: It provides input / output voltages, frequency, load and saving percentage levels, output currents, power factor, load type and temperature. It includes timer, astronomical clock and event data logger.

LIGHTING FLOW DIMMER-STABILISERS

TECHNICAL SPECIFICATIONS
MODEL
TECHNOLOGY INPUT
Voltage Voltage range

ILUEST+
Bidirectional Buck converter with IGBTs, electronic, static and transformerless Single phase: 230 V / Three-phase: 3 x 400 V + 25% / - 7% nominal voltage +25% / - 17% saving voltage HPSV +25% / - 10% saving voltage MV 40 65 Hz Input / output fuses ; electronic for temperature, overload, fault and varistors Switch Ajustable from 215 V to 230 V (220 V as standard) Better than 1% Preset and adjustable Adjustable from 180V to 210V / No lower limit From 1 V/minute to 6 V/minute < 40 ms Lineal and independent per phase 96% 98% 100% permissible Through LCD panel or RS-232 port 150% for 30 seconds; 120% for >1 minute No-break Automatic, reversible, independent per phase, independent operating, input for manual activation Overtemperature, overload, fault, output fault, manual activation Automatic by alarm cancelling. Quantity of retries:10; time between retries: 8 seconds RS-232 and RS-485 SICRES system (COM version) 20 C + 55 C (2) Up to 95%, non-condensing 2,400 m.a.s.l. 50,000 hours 30 minutes Modules built in assembling base (chassis of sheeted steel at carbon cold) with drills to x to the wall Indoor built in a poylester cabinet IP54 Modules + Supports + Control wiring + Power Supply EN 60950-1; UNE AENOR EA 0032-2007 EN 61000-6-2; EN 61000-6-3 UNE AENOR EA 0033-2007 CE ISO 9001 and ISO 14001 TV
(2) 4% power derating per each degree over 45C

Frequency Module protection Equipment protection per phase

OUTPUT

Voltage Accuracy inside voltage range Soft start voltage Saving voltage Speed ramp setting Response time

LCD version

Control Efciency Phase unbalancing Selectable saving voltage 1 or 2 Permissible overload

COM version: Stabiliser module LCD version with SICRES card for remote communication. SICRES card: Interface for Ethernet networks with TCP-IP and SNMP protocols and GSM / GPRS modems and RTC.
BYPASS

Technology Features Activation criteria Rearm

IMPLEMENTATIONS

COMMUNICATION GENERALS

Ports Monitoring Operating temperature Relative humidity Maximum altitude Mean Time Between Failures Mean Time To Repair Acoustic noise at 1 metre

IMPLEMENTATIONS

Indoor Outdoor OEM Kit

Vertical Horizontal

STANDARDS
Indoor horizontal format Outdoor version

Safety Electromagnetic compatibility (EMC) Operating Marking Quality and environmental management

(1) Depending on type of lamp

RANGE
MODEL
OEM kit

POWER
(kVA)
7.5 10 15 20 25 30 45

KIT OEM
QUANTITY OF

MODULES

DIMESNSIONS PER MODULE (D x W x H mm)

WEIGHT (Kg) 11 11 12 12 19 20 20

KIT NET+7.5-4-LCD KIT NET+10-4-LCD KIT NET+15-4-LCD KIT NET+20-4-LCD KIT NET+25-4-LCD KIT NET+30-4-LCD KIT NET+45-4-LCD

3 3 3 3 3 3 3

200 x 172 x 310 200 x 172 x 310 200 x 172 x 310 200 x 172 x 310 200 x 172 x 470 200 x 172 x 470 200 x 172 x 470
(3)

AVAILABLE options
External or internal manual bypass. GSM and GPRS modem. SICRES (converts LCD version to COM). Digital I/O (digital inputs and outputs). Lightning arrestor.

MODEL
NET+ 7.5-4 NET+ 10-4 NET+ 15-4 NET+ 20-4 NET+ 25-4 NET+ 30-4 NET+ 45-4
(3) Horizontal

POWER
(kVA)
7.5 10 15 20 25 30 45

INDOOR IMPLEMENTATION
DIMENSIONS (D x W x H mm)

OUTDOOR IMPLEMENTATION
DIMENSIONS (D x W x H mm) WEIGHT (Kg)

WEIGHT (Kg)

240 x 520 x 610 240 x 520 x 610 240 x 520 x 610 240 x 520 x 610 240 x 520 x 770 240 x 520 x 770 240 x 520 x 770

29 30 31 33 55 56 57

320 x 750 x 1105 320 x 750 x 1105 320 x 750 x 1105 320 x 750 x 1105 320 x 750 x 1105 320 x 750 x 1105 320 x 750 x 1105

64 65 66 68 89 91
(*) Spain only (**) Rest of World

SERVICES
Customized studies and simulations of the saving and payback. Extended warranties (under request). Multiple formulae of maintenance and telemaintenance (SICRES).

90

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


REF. JM638C01 CODE 401AB000416 ED. JANUARY 2011 LIGHTING FLOW DIMMER STABILISER

Data may change without previous notice.

48 dBA (at typical load)

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

ILUEST

LIGHTING FLOW DIMMER STABILISERS ILUEST: Energy savings in outdoor lighting


Current lighting systems, though more and more optimised and more efcient, are also larger in the number of light points and are therefore a larger and larger burden for the public of private entities that deal with its management. The SALICRU ILUEST series is a lighting ow dimmer stabiliser conceived to maximise energy savings in outdoor lighting installations, considerably reducing the electricity bill and at the same time protecting and looking after the lamps to give them a longer life and therefore reduce the critical maintenance costs. Available in a wide range of powers, both in single phase and three-phase, they are made in three different versions and several options, particularly including the remote GSM/GPRS communication, due to its important role in efciently managing the lighting.

OPTIMISED PERFORMANCES
Electronic lighting ow adjustment by static elements and microprocessor control. Entirely independent adjustment per phase. Independent static bypass per phase. Magnetic thermal protection and protection against atmospheric discharges integrated per phase. Efciency > 97%. It does not bring in harmonics or alter the power factor of the installation. Instantaneous stabilisation in all operating states. Work cycle adapted to the initial heating phase of the lamps. Suitable for all kinds of discharge lamps (including metal halogen). Soft transitions between the nominal and reduced ow states. Fine adjustments of all voltage levels and output precision improved by 2%. Selectable start-up voltage. Two saving levels software-adjustable.(1) Additional energy savings through the complete elimination of the night-time overloading.

ILUEST units

Protection with automatic rearmament, overload and over temperature programming. (2) Signicant increase in the life span of the lamps. Monitoring through LED/LCD panel (2) and remote telemanagement, by GSM/GPRS modem (1). Savings of over 40%. Easy installation alongside the control centre or inside it. Average repayment of the investment between 6 and 24 months. Optimised maintenance of the unit.

APPLICATIONS: More efcient outdoor lighting


All of these, from urban public lighting (avenues, streets, roads, ring roads, roundabouts, bridges, etc.) to lighting in industrial areas, shopping centres, car parks, hospitals, ports, railway stations or airports, can benet from the advantages given by the ILUEST in such important aspects as rationality in light levels, maintenance of the installations and electrical consumption.

(1) Optional (2) Depending on the model

LIGHTING FLOW DIMMER STABILISERS

ILUEST
SICRES: total control
SICRES is an electronic card of communication that makes possible the telemaintenance service trough Internet connection. Available for versions with communications.

LIGHTING FLOW DIMMER-STABILISERS


TECHNICAL SPECIFICATIONS
MODEL
INPUT Single phase voltage Three phase voltage Voltage range

ILUEST
120 V, 220 V, 230 V, 240 V 3 x 208 V, 3 x 220 V, 3 x 380 V, 3 x 400 V, 3 x 415 V + 15% / - 8% nominal voltage + 4% / - 29% saving voltage 1 + 10% / - 24% saving voltage 2 48 63 Hz Single pole circuit breaker 120 V, 220 V, 230 V, 240 V 3 x 208 V, 3 x 220 V, 3 x 380 V, 3 x 400 V, 3 x 415 V Better than 2 % Nominal or 210 V (Selectable) 180 V (phase to neutral) adjustable for MV, HPSV, MH and uorescent Independent per phase Nil > 97% From 0.5 lagging to 0.7 leading Permissible 100% Through LCD panel or PC software Automatic static solid built in and independent per phase Operating temperature Relative humidity Maximum altitude Mean Time Between Failures (MTBF) Mean Time To Repair (MTTR) Acoustic noise at 1 metre - 40 C + 45 C Up to 95%, non-condensing 2400 m.a.s.l. 60,000 hours 30 minutes < 35 dB
Data liable to changes without prior notice.
(*) Spain only (**) Rest of World

Frequency Protection per phase OUTPUT Single phase voltage Three phase voltage Accuracy Warm up start voltage
Cartographic map of a park of equipments with SICRES system.

Minimum saving voltage Regulation Harmonic distortion Efciency Permissible power factor Unbalancing between phases Saving voltage selection 1 or 2 (3) BYPASS ENVIRONMENTS

The functions of the system include: Interface for Ethernet networks with TCP-IP and SNMP protocols and GPRS and RTC modems. 10 digital measurements and 17 analogical measurements (12 of voltage, 3 of output current and 2 of temperature). Multiple measurements are available: Active and apparent powers, power factor, load level, etc. Multiple programming and setting parameters: Time, current day and month, selection of two types of lamp, start voltage, nominal and saving. Calibrations. Programming and automatic SMS and email sending. 7 week days + 10 special days time scheduler. Astronomical clock selection and programming is included.
INDICATORS (3)

Optical (per phase) Acoustic (per phase) Monitoring

Process mode, activated saving order Saving On, selected tap, automatic bypass, automatic bypass alarm Automatic bypass alarm LCD display Horizontal Vertical Made of sheeted steel at carbon cold, with holes to be xed to the oor or wall Cabinets made of polyester or metallic of steel at carbon EN-60950-1 EN-61000-6-2; EN-61000-6-3 CE ISO 9001 and ISO 14001 TV

IMPLEMENTATION Indoor version Outdoor version STANDARDS Safety

Electromagnetic Compatibility (EMC) Marking Quality and Environmental management


(3) Depending on the model

RANGE
1 2 3 4 5

Input / Output 230 V

Alarm situation. Information sending / reception. Information analysis / diagnostic. Intervention in-situ from STS (Service & Technical Support). Report sending.
SICRES system operation ow

MODEL
NE 3,5-2 NE 5-2 NE 7,5-2 NE10-2 NE 15-2 NE 20-2

POWER
(kVA) 3.5 5 7.5 10 15 20

INDOOR VERSION
DIMENSIONS
(D x W x H mm.)

OUTDOOR VERSION
WEIGHT
(Kg)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

220 x 270 x 550 220 x 270 x 550 220 x 270 x 550 220 x 270 x 550 220 x 270 x 550 220 x 270 x 650

42 43 45 46 50 67

320 x 500 x 860 320 x 500 x 860 320 x 500 x 860 320 x 500 x 860 320 x 500 x 860 320 x 500 x 860

72 73 75 76 80 105

AVAILABLE options
Manual bypass to electrically isolate the unit during maintenance work. Automatic bypass to contactors, per phase or common. Astronomic clock for better control of sunrise and sunset. (1) Atmospheric gas discharger. Control card to provide digital and analogical input/outputs. (2)

Input / Output 3 x 400 V

MODEL
NET 7,5-4 NET 10-4 NET 15-4 NET 20-4 NET 25-4 NET 30-4 NET 45-4 NET 60-4 NET 80-4 NET 100-4 NET 120-4

POWER
(kVA) 7.5 10 15 20 25 30 45 60 80 100 120

INDOOR VERSION
HORIZONTAL DIM.
(D x W x H mm.)

OUTDOOR VERSION
WEIGHT
(Kg)

VERTICAL DIM.
(D x W x H mm.)

DIMENSIONS
(D x W x H mm.)

WEIGHT
(Kg)

235 x 653 x 840 235 x 653 x 840 235 x 653 x 840 235 x 653 x 840 235 x 653 x 840 235 x 653 x 840 235 x 653 x 840 260 x 653 x 1070 350 x 653 x 1070 350 x 653 x 1070 350 x 800 x 1070

275 x 350 x 800 275 x 350 x 800 275 x 350 x 800 275 x 350 x 800 275 x 350 x 800 275 x 350 x 800 275 x 350 x 800 -

60 80 81 82 90 95 139 181 204 214 225

320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1098 320 x 770 x 1348 420 x 770 x 1348 420 x 770 x 1348 420 x 1020 x 1348

94 116 117 118 125 130 173 221 244 254 265

SERVICES
Studies and personalised saving and repayment simulations. Extended warranties (to be consulted). Multiple formulae of maintenance and telemaintenance (SICRES).
(1) Included in communication equipment. (2) Only for communications equipment.

WWW.SALICRU.COM
REF. JM610C01 CODE 401B000469

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


ED. JANUARY 2011 LIGHTING FLOW DIMMER STABILISERS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

EQUINOX

PHOTOVOLTAIC INVERTERS 2,8 kW - 4 kW - 5 kW - 10 kW EQUINOX: New solutions in solar inverters for net connection

SALICRUs EQUINOX series being solar inverters without transformer feature being light, dimension reduced and with high reliability. Due to its novel technology, backep by SALICRUs wide experience within power electronics world, they offer low power set-up high performance, as well as a wide range communication capacity. Moreover, set-up and use maximum ease for a greater working out comfort. Full range covers 2,8, 4, 5 and 10 kW power, connected to single-phase or 3-phase net either for indoor or outdoor set-up. All have LCD and/or graph screen to ease set-up data look on, as well as local or remote communication feasability.

PERFORMANCES
PWM technology with transformerless electronic insulation. Maximum Power Point Tracker system (MPPT). High conversion efcieny > 97%. Multi-string connection choice: 1 to 3 MPPT. Power factor > 0,99. Plug & Play connect. Indoor and outdoor introduction. GFCI (Ground Fault Circuit Interruptor) so as to avail grounding leak advanced control. Simple set-up via light and manyfold assembly bracket included. LCD display with all needed information; graph screen for 10 kW model. RS-232 and RS-485 (1) ports . Datalogger for data pick-up up to 100 inverters (2). Acoustic noise decrease via natural airing. IP65 protect (3).

Equinox 5000-3M

Equinox 10000

(1) Optional

(2) Except 2,8 kW model


Equinox 4000 Equinox 2800

APPLICATIONS: Manyford maximum performance


SALICRUs EQUINOX series inverters indoor and outdoor tting-wise, ranging from little power to great ones via parallel inverters, achieving congurations which target a greater level of realiability due to modular outlook. Moreover, maximum exibility offered being single phase of three-phase connect inverters. Plus multistring - Equinox 5000-3M & Equinox 10000 models - topology set-up connect suitable, allowing photovoltaic eld Design & Planning maximum tting.

PHOTOVOLTAIC INVERTERS

EQUINOX
EASY installation
As low frequency heavy parts have been removed, it is achieved a very slight inverter that facilitates maximum its installation. It includes support for easy and versatile assembling that simplies the installation.

PHOTOVOLTAIC INVERTERS

TECHNICAL CHARACTERISTICS
MODEL
INPUT
Nominal voltage Open circuit maximum voltage MPPT rank (1) Working-out ranck Nr. MPP trackers Input maximum current per traker
Maxumum DC input power per tracker

EQX 2800
360 VDC 500 VDC 250 - 450 VDC 100 - 500 VDC 1 13 A 3,250 W 3,000 W

EQX 4000
360 VDC 500 VDC 250 - 450 VDC 100 - 500 VDC 1 20 A 5,000 W 4,400 W Single phase 230 VAC

EQX 5000-3M
600 VDC 750 VDC 450 - 750 VDC 100 - 700 VDC 3 8.5 A 3,825 W 5,000 W

EQX 10000
640 VDC 800 VDC 320 - 720 VDC 280 - 800 VDC 3 13 A 5,500 W 11,000 W Three-phase 3 x 400 VAC

OUTPUT

Maximum power Network voltage Nominal voltage

MONITORING
EQUINOX inverters have, as standard, RS-232 communication. Also, there are several optionals to make easy its monitoring and communication: - RS-485 card: it allows connecting with the SolarLog dataloggers, or monitoring through the Procontrol software directly.

Voltage margins Frequency AC maximum current THDi harmony distortion Power factor Maximum efciency 14.3 A

+ 10% / - 15% 50 Hz 2% 20 A < 3% > 0,99 > 96% > 95% Transformerless - 20 C +55 C Up to 95%, non-condensing IP43 < 35 dB <7W < 0.1 W Natural 5 years RS-232 and RS-485 (2) Open SALICRU and Modbus RTU (2) Data pick-up upp to 100 inverters 2 lines x 16 characters IEC 62103 / EN 50178 EN 61000 CE ISO 9001 and ISO 14001 TV 128 x 64 graph screen
Data may change without previous notice. (*) Spain only (**) Rest of World

24 A

18.7 A

> 96.5%

GENERALS

EU efciency Topology Room temperature Relative humidity Closure Acoustic sound level Non-use consumption Stand-by consumption Cooling

IP65 < 45 dB < 30 W < 3.5 W Forcing

WARRANTY

Warranty

COMMUNICATION Ports Protocol Datalogger (2) Display LCD

- MODBUS RTU RS-485 card: enables to monitor the inverters with a SCADA system. - Data Logger: which monitors data of all EQUINOX inverters that are connected in the installation and concentrates and stores all information for its later consultation via Ethernet or GPRS.

STANDARDS

Safety Electromagnetic Compatibility (CEM) Marking Quality and Environmental management

(1) 100% energy re-injection (2) Optional

RANGE
MODEL
EQX 2800 EQX 4000 EQX 5000-3M EQX 10000

DIMENSIONS
(D x W x H mm.)
135 x 350 x 302 136 x 386 x 434 130 x 430 x 531 155 x 455 x 585

WEIGHT
(Kg)

12.5 19.7 27 35

- ProControl software: it allows monitoring the operating and any parameter from EQUINOX inverters, by means of the communications RS-232 and RS-485 options.

WWW.SALICRU.COM
REF. JM687B01 CODE 401B000513

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX +34 93 848 11 51


ED. JANUARY 2011 PHOTOVOLTAIC INVERTERS

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SICRES

TELEMAINTENANCE SERVICE SICRES: Complete surveillance of your equipment

The units for protecting and controlling critical loads are normally installed in locations away from the passing or working areas, which prevents information from being obtained on the state and alarms without sending a technician to the place of the installation. Sometimes this lack of information means not having the protection equipment in the best state, causing considerable losses of data, production line downtimes, etc. To be informed at all times of the state and even anticipate possible faults in the equipment, SALICRU offers the SICRES solution; the internet telemaintenance service with different forms: BASIC, MEDIUM, PREMIUM and PREMIUM PLUS, which will allow the customer to be advised in the event of a fault, the equipment to be monitored via web and to be accessed for control, amongst other things, thus avoiding the unnecessary movement of maintenance personnel and reporting and solving problems before the user notices them.

Normal status

NON urgent alarm

URGENT alarm

3
SICRES operating ow Alarm location. Sending/reception of information. Analysis/diagnosis of information. In-situ intervention of our STS (Service & Technical Support). 5 Report sending.
1 2 3 4

4 5

ADVANTAGES & SERVICES


With the SICRES system, you can concentrate entirely on your business and forget about the surveillance and management of your SALICRU protection systems. Leave this responsibility in our hands, and work peacefully. The SICRES telemaintenance allows monitoring, analysis and technical support in real time, 24/7 by SALICRU professionals, thus reducing the MTTR (mean time to repair) in any unexpected event. During the monitoring, an events and alarms log is created that allows exhaustive analysis of the equipment, providing valuable information on the operating tendency and thus identifying potential future problems. Likewise, every month a detailed report is sent on the state of the customers equipment. For events and/or alarms that the customer considers more important SICRES will send electronic mails and SMS messages to instantly report the incident and start the suitable corrective action at the same time.

SERVICE & TECHINCAL SUPPORT

SICRES
MONITORING & control
Personalised screens for perfect unit localisation.

TELEMAINTENANCE SERVICE

FORMS
MODEL
Monitoring from SALICRU Web Monitoring Telephone support Monthly reports Remote access to the unit Customer-owned system

BASIC

MEDIUM

PREMIUM PREMIUM+

(1)

(1)


(1)


Data may change without previous notice. (*) Spain only (**) Rest of World

Equipment location

SMS sending Electronic mail

Unit alarms and measurements in real time.

Technical support on location Maintenance contract Unit parameter adjustment


(1) Consult kinds of maintenance contract.

REQUIREMENTS
Have a maintenance contract.
Equipment data

SICRES SNMP/WEB ADAPTER compatible with the unit. Internet connection.

VERSIONS
To perfectly integrate SICRES in all products of the SALICRU range, both current equipment and the previous series, there are two versions: SICRES CARD: For product ranges with a slot for the SICRES card. This avoids having small units around the equipment. SICRES BOX: When the unit does not have a slot, the SICRES adapter can be installed externally.

COMPATIBILITY
SERIES
SPS.ADVANCE SPS.TOP SLC LINK SLC TWIN UPS NX SLC NEXT UPS DL SLC CUBE SLC CUBE STR SLC CUBE 3 SLC ELITE SLC ELITE MAX ILUEST ILUEST+ CS IS OPTIMUS
(2) Equipment 1500 VA

SICRES CARD

SICRES BOX

SICRES + SNMP TH GX

(2)

SICRES CARD

SICRES BOX

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


REF. JM658A01 CODE 401AB000456 ED. JANUARY 2011 SERVICE & TECHNICAL SUPPORT

UNIN T ERRUP T IBL E P OW ER SUP PL IES (UP S) + L IGH T ING FLOW DIMMER-S TA BIL ISERS + VOLTAGE S TA BIL ISERS & P OW ER L INE CONDI T IONERS + DC P OW ER SYS T EMS + S TAT IC IN V ER T ERS + P HOTOVOLTA IC IN V ER T ERS

SOFTWARE - ADAPTERS
MANAGEMENT & MONITORING SOFTWARE - ADAPTERS: The best complements for a ful protected installation
An Uninterruptible Power Supply (UPS) is needed to protect electrical installations from disturbance and avoid damage to the loads or losse of data. However, this protection will not be complete until the user has a completely autonomous system that informs them of the status of the UPS and proceeds to perform precongured actions. This system consists of the management and monitoring of the UPS in real time, to allow full remote control of it all times by means of software installed in a PC/Server and/or Ethernet/SNMP Web adapter. SALICRU offers this complete solution with the: UNMS II, RCCMD, WINPOWER and VIEWPOWER softwares and the different Ethernet/SNMP Web adapter available for each of the UPS series.

ETHERNET/SNMP Adapters: IP network integration


For the perfect integration of the UPS in the computer network, the best thing is not to depend exclusively on a computer, which is why the Ethernet/SNMP Web adapter (Single Network Management Protocol)enables the UPS to be completely independent without any need to have a PC or server associated. BOX and CARD versions: Allowing the UPS to be integrated in the computer network. Available in box and insertable card version for the intelligent slots of the SALICRU equipment. There is also the possibility of connecting temperature and humidity sensors and TCP RS-232 and RS-485 communication with , Modbus protocol.

RCCMD: Remote shutdown application


It becomes virtually impossible to manage and monitor a UPS in heterogeneous computer networks where different system converge, for the less common operating system on the market do not have this software. The RCCMD is an application that allows the simultaneous and secure shutdown of the different servers or Workstations of 95% of the existing platforms. Like the most complete monitoring softwares, the RCCMD is capable of launching messages or commands to the diferent clients of the network. Different actions are executed by customized scripts, when the order from the SNMP Web adapter is received. Compatible with all operating systems, even with virtual systems.

Highlighted functionalities
Web monitoring of main parameters and status of each equipment (mains failure, mains restored , inverter fault, bypass transference,...). Warning electronic mail or SMS sending (depending on the availability of the IT environment). Capacity to be integrated in SNMP platforms (Nagios). Closing les and servers arranging by means of RCCMD software. MODBUS protocol included to be integrated in industrial applications; available by means of TCP RS-232 or , RS-485. v

UNMS II: Unlimited UPS management


For networks with more than one UPS to feed the and which require monitoring concentration from a single control post, the UNMS II (UPS Network Managament System) software is the ideal solution. The UNMS II allows the management of multiple installations of all devices that have an Ethernet/SNMP Web adapter and/or sensors. The UNMS II has different levels or licences, which depend on the number of UPS to be managed. Except for the basic level, when the UNMS II licence is acquired, a screen can be personalised to make the management of all the UPS much easier and intuitive.

SERVICE & TECHNICAL SUPPORT

ADAPTER SOFTWARE
WINPOWER & UPSMON: The best UPS control
When you have a single work station of a small computer network, the UPS used for their protection are single phase low or medium power, which means they have to be implemented in the system management. The WINPOWER and VIEWPOWER softwares allow shutdowns to be monitored and controlled in the PCs where they are installed, and electronic mails, SMS messages or broadcasts to be sent, amongst other functions.

MANAGEMENT & MONITORING

TECHNICAL CHARACTERISTICS
SOFTWARE
RCCMD WINPOWER VIEWPOWER

ETHERNET/SNMP ADAPTERS
SNMP/WEB ADAPTER TH BOX GX5 TH CARD GX5 BOX GX5 CARD GX5

Monitoring (software installed in PC) Web Browser viewing RS-232 Communication port USB Communication port Ethernet TCP/IP Port Ordened shutdown of the PC /server Sending electronic mails MODBUS Protocol (RS-232 port) MODBUS Protocol (TCP) Software UPS shutdown Location in UPS slot Monitoring of the main parameters of the UPS Broadcast (window) of warning in the event of alarm

Winpower

Different user/administrator levels Time synchronisation Event log Value log Temperature and humidity sensor connection

Viewpower

COMPATIBILITY
SOFTWARE SERIES
SPS.HOME SPS.HOME 2011 SPS.ONE SPS.SOHO SPS.PRO SPS.ADVANCE SPS.TOP SLC LINK SLC TWIN UPS NX
RCCMD WINPOWER VIEWPOWER UPSMON

ETHERNET/SNMP ADAPTERS
SNMP/WEB ADAPTER TH BOX GX5 TH CARD GX5 BOX GX5 CARD GX5

OPTIONAL
SENSORS: For cases where it is essential to have all the environmental data of the room where the UPS is located, there is a temperature and humidity sensor that allows these data to be included from the monitoring software without resorting to a totally external system. The sensor includes communication cable with the Ethernet/SNMP Web adapter. DISPLAY: The perfect view of the parameters of the UPS from a distance by means of a display that shows any parameter from the Ethernet/ SNMP Web adapter or RCCMD software.

SLC NEXT UPS DL SLC CUBE SLC CUBE STR SLC CUBE3 SLC ELITE SLC ELITE MAX
(1) Equipments 1500VA

(1)

(1)

Display size 400 mm x 110 mm.

Display size 1300 mm x 110 mm.

WWW.SALICRU.COM
REF. JM653B01 CODE 401AB000457

AVDA. DE LA SERRA 100 08460 PALAUTORDERA SPAIN FAX 93 848 11 51


ED. JANUARY 2011 SERVICE & TECHNICAL SUPPORT

(*) Spain only (**) Rest of World

Data may change without previous notice.

U N I N T E RRU P T I B L E P O W E R SU P P L I E S (U P S) + L I G H T I N G F L O W D I M M E R- S TA B I L I SE R S + V O LTAG E S TA B I L I SE R S & P O W E R L I N E C O N D I T I O N E R S + D C P O W E R S Y S T E M S + S TAT I C I N V E R T E R S + P H O T O V O LTA I C I N V E R T E R S

Avda. de la Serra 100 08460 Palautordera BARCELONA. Spain Tel. +34 93 848 24 00 Fax +34 93 848 11 51 comercial@salicru.com SALICRU.COM

DELEGATIONS and SERVICE & TECHNICAL SUPPORT (STS) BARCELONA BILBAO GIJN LA CORUA LAS PALMAS DE G. CANARIA MADRID MLAGA MURCIA PALMA DE MALLORCA PAMPLONA SAN SEBASTIN SEVILLA VALENCIA VALLADOLID ZARAGOZA

SUBSIDIARIES CHINA FRANCE HUNGARY MEXICO PORTUGAL SINGAPORE UNITED KINGDOM

REST OF WORLD ALGERIA ARGENTINA BELGIUM BRAZIL CHILE COLOMBIA CUBA CZECH REPUBLIC DENMARK ECUADOR EGYPT GERMANY HOLLAND INDONESIA IRELAND JORDAN KUWAIT MALAYSIA MOROCCO PERU PHILIPPINES POLAND RUSSIA SAUDI ARABIA SWEDEN SWITZERLAND THAILAND
NB: Salicru can offer other power electronics solutions depending on the specications of the application or the technical requests.

TUNISIA UAE URUGUAY VENEZUELA VIETNAM

Product Range Uninterruptible Power Supplies (UPS) Lighting Flow Dimmer Stabilisers Voltage Stabilisers & Power Line Conditioners DC Power Systems Static Inverters Photovoltaic Inverters

SALICRU

REF. JM639E01

CODE 401AB000418

ED. MARCH 2011

PRODUCT RANGE CATALOGUE - MARCH 2011