Documente Academic
Documente Profesional
Documente Cultură
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
The heat transfer coefficient, in thermodynamics and in mechanical and chemical engineering, is used in calculating the heat transfer, typically by convection or phase change between a fluid and a solid:
where Q = heat input or heat lost, J h = heat transfer coefficient, W/(m2K) A = heat transfer surface area, m2
T = difference in temperature between the solid surface and surrounding fluid area, K t = time period, s
From the above equation, the heat transfer coefficient is the proportionality coefficient between the heat flux, Q/(At), and the thermodynamic driving force for the flow of heat (i.e., the temperature difference, T). The heat transfer coefficient has SI units in watts per meter squared-kelvin [W/(m2K)]. Heat transfer coefficient is the inverse of thermal insulance. There are numerous methods for calculating the heat transfer coefficient in different heat transfer modes, different fluids, flow regimes, and under different thermohydraulic conditions. Often it can be estimated by dividing the thermal conductivity of the convection fluid by a length scale. The heat transfer coefficient is often calculated from the Nusselt number (a dimensionless number).
Contents
1 DittusBoelter correlation (forced convection) 2 Thom correlation 3 Heat transfer coefficient of pipe wall 4 Combining heat transfer coefficients 5 Overall heat transfer coefficient 6 Thermal resistance due to fouling deposits 7 References 8 See also 9 External links
1 de 6
12/04/2010 8:30
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
only mode of heat transfer; i.e., there is no boiling, condensation, significant radiation, etc. The accuracy of this correlation is anticipated to be 15%. For a liquid flowing in a straight circular pipe with a Reynolds number between 10 000 and 120 000 (in the turbulent pipe flow range), when the liquid's Prandtl number is between 0.7 and 120, for a location far from the pipe entrance (more than 10 pipe diameters; more than 50 diameters according to many authors[1]) or other flow disturbances, and when the pipe surface is hydraulically smooth, the heat transfer coefficient between the bulk of the fluid and the pipe surface can be expressed as:
where
Thom correlation
There exist simple fluid-specific correlations for heat transfer coefficient in boiling. The Thom correlation is for flow boiling of water (subcooled or saturated at pressures up to about 20 MPa) under conditions where the nucleate boiling contribution predominates over forced convection. This correlation is useful for rough estimation of expected temperature difference given the heat flux:[3]
where:
2 de 6
12/04/2010 8:30
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
where k is the effective thermal conductivity of the wall material and x is the wall thickness. If the above assumption does not hold, then the wall heat transfer coefficient can be calculated using the following expression:
where di and do are the inner and outer diameters of the pipe, respectively. The thermal conductivity of the tube material usually depends on temperature; the mean thermal conductivity is often used.
For two or more heat transfer processes connected in series, heat transfer coefficients add inversely:[4]
For example, consider a pipe with a fluid flowing inside. The rate of heat transfer between the bulk of the fluid inside the pipe and the pipe external surface is:
where Q = heat transfer rate (W) h = heat transfer coefficient (W/(m2K)) t = wall thickness (m) k = wall thermal conductivity (W/mK) A = area (m2)
T = difference in temperature.
3 de 6
12/04/2010 8:30
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
For the case of a heat exchanger, U can be used to determine the total heat transfer between the two streams in the heat exchanger by the following relationship:
Q = UATLM
where
Q = heat transfer rate (W) U = overall heat transfer coefficient (W/(mK)) A = heat transfer surface area (m2) TLM = log mean temperature difference (K)
The overall heat transfer coefficient takes into account the individual heat transfer coefficients of each stream and the resistance of the pipe material. It can be calculated as the reciprocal of the sum of a series of thermal resistances (but more complex relationships exist, for example when heat transfer takes place by different routes in parallel):
where R = Resistance(s) to heat flow in pipe wall (K/W) Other parameters are as above.[5] The heat transfer coefficient is the heat transferred per unit area per kelvin. Thus area is included in the equation as it represents the area over which the transfer of heat takes place. The areas for each flow will be different as they represent the contact area for each fluid side. The thermal resistance due to the pipe wall is calculated by the following relationship:
where x = the wall thickness (m) k = the thermal conductivity of the material (W/(mK)) A = the total area of the heat exchanger (m2) This represents the heat transfer by conduction in the pipe. The thermal conductivity is a characteristic of the particular material. Values of thermal conductivities for various materials are listed in the list of thermal conductivities. As mentioned earlier in the article the convection heat transfer coefficient for each stream depends on the type of fluid, flow properties and temperature properties. Some typical heat transfer coefficients include: Air - h = 10 to 100 W/(m2K) Water - h = 500 to 10,000 W/(m2K)
4 de 6
12/04/2010 8:30
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
Uexp = overall heat transfer coefficient based on experimental data for the heat exchanger in the
"fouled" state,
Upre = overall heat transfer coefficient based on calculated or measured ("clean heat exchanger")
data,
References
1. 2. 3. 4. ^ S.S. Kutateladze and V.M. Borishanskii, A Concise Encyclopedia of Heat Transfer, Pergamon Press, 1966. ^ F.Kreith (editor), "The CRC Handbook of Thermal Engineering", CRC Press, 2000. ^ W.Rohsenow, J.Hartnet, Y.Cho, "Handbook of Heat Transfer", 3rd edition, McGraw-Hill, 1998. ^ This relationship is similar to the harmonic mean; however, note that it is not multiplied with the number n of terms. 5. ^ Coulson and Richardson, "Chemical Engineering", Volume 1,Elsevier, 2000 6. ^ Turner C.W.; Klimas S.J.; Bbrideau M.G., "Thermal resistance of steam-generator tube deposits under single-phase forced convection and flow-boiling heat transfer", Canadian Journal of Chemical Engineering, 2000, vol. 78, No 1, pp. 53-60
See also
Thermal conductivity Heat Heat pump Thermal-hydraulics Churchill-Bernstein Equation
External links
Overall Heat Transfer Coefficients (http://www.cheresources.com/uexchangers.shtml) Correlations for Convective Heat Transfer (http://www.cheresources.com/convection.shtml)
5 de 6
12/04/2010 8:30
http://en.wikipedia.org/wiki/Heat_transfer_coefficient
Heat Transfer fundamentals (http://www.hrs-spiratube.com/en/resources /heat_transfer_fundamentals_01_05.aspx) Retrieved from "http://en.wikipedia.org/wiki/Heat_transfer_coefficient" Categories: Convection | Heat transfer | Heat conduction This page was last modified on 3 March 2010 at 13:53. Text is available under the Creative Commons Attribution-ShareAlike License; additional terms may apply. See Terms of Use for details. Wikipedia is a registered trademark of the Wikimedia Foundation, Inc., a non-profit organization.
6 de 6
12/04/2010 8:30