2010 UTC Fire & Security. All rights reserved. The AL-1809 / CA1809 / ATS1809 Universal Interface name and logo are trademarks of UTC Fire & Security. GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065 Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Manufacturer
UTC Fire & Security Americas Corporation, Inc. 1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands
FCC compliance
AL-1809 Universal Interface complies with part 15 of the FCC rules. Operation is subject to the following conditions: This device may not cause harmful interference This device must accept any interference received, including interference that may cause undesired operation.
Certification European Union directives 1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Contact information For contact information see our Web site: www.utcfireandsecurity.com.
Content
Product overview 1 Main features 2 Web interface 2 Installer and cabling requirements 3 Installation 5 Overview 5 Setting up the control panel 5 Setting up the installation computer 5 Installing the Universal Interface 6 Programming 9 Logging in 10 User name and password 10 Network settings 10 ATS panel options 12 Firewall rules 13 Email/TFTP parameters 14 Network Receiver parameters 15 Message format 16 Finishing the installation 17 After a full installation 17 Reference section 18 Additional programming 18 RAS keystrokes to program the computer address 19 RAS keystrokes to program the security password 19 RAS keystrokes to program central station parameters 19 Using the default jumper 20 LED indication 21 Universal Interface utilities 21 Sample network diagram 22 Specifications 24 Software 24 Network primitive frame size (bytes) 24 Hardware 24 Installation worksheet 26
ii
Product overview
The AL-1809/CA1809/ATS1809 Universal Interface (Universal Interface) acts as a gateway between an ATS alarm panel and the outside world. It includes an embedded web server to enable the installation technician to program all the necessary configuration options of the Universal Interface by means of a web browser on a computer. The Universal Interface enables an ATS control panel to communicate with security management systems via Internet protocol (IP).
Figure 1: Typical system layout for IP communication
1
IP aaa.aaa.aaa.aaa 2 3 4 6 5 IP bbb.bbb.bbb.bbb 7
1. SecureStream* or UTC Fire & Security Network Receiver, IP aaa.aaa.aaa.aaa 2. UTC Fire & Security Network Receiver, IP bbb.bbb.bbb.bbb 3. ATS Control Panel 3. UTC Fire & Security Network Receiver, IP ccc.ccc.ccc.ccc 4. Universal Interface 5. LAN or WAN 6. Computer and Printer Interface 8. PC with web-browser, IP eee.eee.eee.eee (used to program the Universal Interface during installation) 9. ATS8300, IP ddd.ddd.ddd.ddd * SecureStream is only used in Australia.
Tx1 Rx1
CON3
CON4
GND-LNK
TX OUT
EA RTH
RX IN
+12V
GND
GND
CTS
RTS
1. 2. 3. 4.
5. 6. 7. 8.
Note: The ground jumper (GDN-LNK) is used only if GND is set to Earth on the control panel.
Main features
Main features of the Universal Interface: May be mounted in an ATS control panel enclosure. Acts as a gateway between the control panel and multiple management systems including ATS8000/ATS8300, SecureStream, and the UTC Fire & Security Network Receiver. Transmits Contact ID (CID Large) and Security Industry Association (SIA) data via Internet protocol (IP) connection. Communicates with management systems across the WAN or LAN. Uses negligible network bandwidth. Supports encrypted communications. Supports TCP/IP and UDP/IP protocols. Initial programming by web interface on installers PC. Firewall can be easily set up for ports to allow or deny IP protocols. The ATS control panel must be fitted with an ATS1801 Computer & Printer Interface. The ATS1809 supports both 10 Mb/s and 100 Mb/s Ethernet connections.
Notes
Web interface
The Universal Interface has a built-in web server that is used to program, check status, update the firmware, and restart the Universal Interface.
The installation technician initially opens the programming web pages at the Universal Interfaces default IP address (http://192.168.0.100) using a web browser on an installation computer. In order to do so: The installation computer must be temporarily assigned an IP address within the 192.168.0.0 subnet, which permits the installation computer access to the address http://192.168.0.100. It is recommended to connect the Ethernet ports of the installation computer and the Universal Interface by means of a UTP cross over lead (it is possible that the clients network will not permit communication within the 192.168.0.0 subnet).
A new IP address is assigned to the Universal Interface by the clients network administrator. When the Universal Interface is restarted or reset (and the default jumper is not fitted) the assigned IP address takes effect and is used for any subsequent programming.
Figure 3: Simplified wiring diagram for Universal Interface to ATS control panel
1
CON4
2
TX OUT EARTH RX IN +12V GND GND CTS RTS
1. ATS1809 Universal Interface 2. To ATS panel 3. Battery Table 1: Connection AL-1809/CA1809/ATS1809 GND TX OUT RX IN RTS CTS EARTH Connections
ATS3000 / 4000
-----------------------------------------------------------------------------------------------------------------------------------------------------------------
GND +12V
-----------------------------------------------------------------------------------------------------------
Installation
Overview
In order for you to install and program a Universal Interface, you must first: Use an LCD RAS on the control panels LAN to obtain (or program) the panels computer address and security password, and to program central station reporting (if required). See Setting up the control panel below. Set up the installation computer on which you will use a web browser to program the Universal Interfaces configuration options. See Setting up the installation computer below. Obtain a number of details about the installation from various sources. These details are listed on a blank installation worksheet on page 26 that you can copy for reuse.
The overall process of installing a Universal Interface consists of the following tasks. Setting up the control panel described below Setting up the installation computer described below Installing the Universal Interface described on page 6 Programming described on page 9 Finishing the installation described on page 17
The following example is for Internet Explorer 5. Use the correct procedure for your particular web browser. To configure the proxy: 1. Start the web browser (Internet Explorer). 2. In Internet Explorer, select Tools > Internet Options > Connections > LAN Settings > Advanced. 3. In the Exceptions window, type the default static IP address of the Universal Interface, followed by a semi-colon, followed by the assigned static IP address (provided by the local network administrator). For example, type 192.168.0.100;10.203.0.15 (where 10.203.0.15 is the IP address for the Universal Interface, as provided by the local network administrator), and click OK (see Figure 4 below).
Figure 4: Example of proxy settings for bypassing specific addresses
2. If not already done so, install a ATS1801 Computer and Printer Interface (not supplied) on the control panel, following the instructions contained in the ATS1801 Installation Guide. The ATS1801 Computer and Printer Interface provides an RS232 connection between the control panel and the Universal Interface. 3. Mount the Universal Interface in the ATS control panel enclosure. Note: The distance from the ATS control panel to the Universal Interface must not exceed 1 meter. 4. Connect the ATS1801 Computer & Printer Interface Computer port to the Universal Interface, using the supplied plug-on screw terminals. See the simplified wiring diagram in Figure 3 on page 4 for details. 5. Connect GND to Earth using jumper GDN-LNK. See Figure 2 on page 2 for the location of GDN-LNK. Note: This step applies only if GND is set to Earth on the control panel. Configuration This procedure may be used for all ATS control panels and must be used in all cases where the Universal Interface does not have the factory-default settings (e.g. a previously-fitted unit). Note: The installation computer must be temporarily assigned an IP address within the 192.168.0.0 subnet, which permits the installation computer access to the address http://192.168.0.100. To configure the universal interface: 1. Change the installation computers IP address settings to be within the 192.168.0.0 subnet, i.e. 192.168.0.X, where X is any number from 1-254 (do not use 192.168.0.100 as the Universal Interface uses this). Record the installation computers original settings so that you can restore them after programming the Universal Interface at the default address. 2. Fit the Universal Interfaces default jumper (DEF) to default the Universal Interface to the factory settings. See Using the default jumper on page 20 for details. 3. Attach power cables between the Universal Interface, and battery wires and the auxiliary power terminals on the ATS control panel (or other 12 VDC power source), using the taps from the accessory bag. See also Figure 3 on page 4. 4. Connect the Ethernet ports of the installation computer and the Universal Interface by means of a UTP cross over lead. Alternatively, connect the Internet/Ethernet cable from the Universal Interface to your network IP connection point (however, it is possible that the clients network will not permit communication within the 192.168.0.0 subnet). 5. Re-power the ATS control panel (or other 12 VDC power source) to power the Universal Interface.
6. Go to Programming on page 9 to program the static address parameters and all remaining options via the default IP address. 7. Follow the appropriate procedures in Finishing the installation on page 17 to complete the installation.
Programming
When you perform an installation, use the default IP address (http://192.168.0.100) to open the Universal Interfaces programming web pages. Program all required options including the static address parameters. See Configuration on page 7 for details. The Universal Interface welcome screen displays.
Figure 5: Universal Interface displayed in web browser
The Universal Interface web pages display a menu on the left-hand side of the window that you will use to access various programming options. In this section you will program the following options: User name and password on page 10 Network settings on page 10 ATS panel options on page 12 Firewall rules on page 13 Optional Email/TFTP parameters on page 14 Network Receiver parameters on page 15
Program the options using the information that you recorded on the Installation worksheet on page 26.
Logging in
Click Login in the User Authentication section of the Universal Interface menu to display the login window. Use the default user name ADVISOR MASTER (case sensitive), and password 998765, to log in to the Universal Interface and begin a session. It is important to note that: Login sessions automatically terminate after five minutes. If you need more than 5 minutes to complete your work, logout and login again to begin a new 5-minute session. If an incorrect user name/password is entered more than five times, more attempts to log in will be delayed by about 60 seconds. After about 60 seconds, logins are allowed as usual. When programming the Universal Interface, you must save your changes using the Submit button on each page before you refresh the web browser or logout, otherwise your changes will be lost. You may need to refresh the web browser in order to see the latest data from the Universal Interface.
Network settings
To set up the network: 1. Click Static Address Parameters in the Network Setup section of the Universal Interface menu to display the network parameters setup window. Type the new IP address, net mask and gateway address (provided by the local network administrator) for the Universal Interface and click Submit. 2. The Universal Interface should be configured to communicate with central station reporting and/or management software. Click Central Station Parameters in the Network Setup section of the Universal Interface menu and type the IP addresses for any CID site or management software site collecting ATS panel events via IP. Three entries are available for reporting to a UTC Fire & Security Network Receiver (listed under Alarm Reporting Central Station), and twelve are available for communication to management applications (listed as entry 4 15 under Management Central Stations): Alarm Reporting Central Station 1 is the main UTC Fire & Security Network Receiver
AL-1809 / CA1809 / ATS1809 Universal Interface Installation and Programming Guide
10
Alarm Reporting Central Station 2 is the backup UTC Fire & Security Network Receiver Alarm Reporting Central Station 3 is the disaster UTC Fire & Security Network Receiver Management Central Station 4 to 15 are for ATS8000/ATS8300 management software
For each IP address, select the options for Protocol, Port, Event type, and Encryption. See Figure 6 on page 12 for details, and Table 2 below for allowable settings. Click Submit. 3. Network probing is an additional feature that will send a message using TCP port 22222 to all programmed IP addresses in Central Station parameters. The first to return an answer will prevent the Universal Interface from generating a Line fault with Universal E-Link error. When enabled, firewall rules should be setup such that they do not block this message (this includes the Windows XP firewall). At least one PC in the programmed list should remain active. When disabled, no network probing is performed. Normal polling mechanisms however remain in operation. This test is performed every 12 seconds. Note: When finished programming the Universal Interface, click Restart Communications in the Utilities section of the main menu to update the system data.
Table 2: Allowable central station parameters Allowable settings Protocol Data type Event type Encryption UTC Fire & Security Network Receiver TCP Event CID, SIA, or XSIA Triple DES SecureStream UDP Event CID only ATS8000/ATS8300 UDP Event Computer event only
11
Note: Management software (ATS8300) must not use the same port number as SecureStream.
12
To set the panel options: 1. Click Panel Physical Address in the Panel Setup section of the Universal Interface menu. Type the correct computer address (Installer menu 19 29 in the control panel) and click Submit. The value may not be 0. 2. Click Panel Security Password in the Panel Setup section of the Universal Interface menu. Type the 10-digit password and click Submit. This password must match the security password that was keyed in the ATS panel at menu 19 29 during installation. Tip: As a precaution, delete any temporary files your browser creates each time the security password is submitted. Tip: The security password can also be changed using Titan Advanced or Alliance 8300 once connection is established. 3. Click Twofish Encryption Key in the Panel Setup section of the Universal Interface menu. Typing in all zeros disables encryption, even if enable is selected. Accepts up to 16 numbers, each three-digit number in each field can be from 0 to 255. Keep a record of your encryption key. Click Enable and Submit. Tip: As a precaution, delete any temporary files your browser creates each time encryption is submitted. Note: When finished programming the Universal Interface, click Restart Communications in the Utilities section of the main menu to update the system data.
Firewall rules
Firewall rules allow you to accept or deny one or more selected communication protocols and associated data. Adding a new rule to accept a protocol doesnt stop communication with other protocols. To deny a protocol you need to either set up a specific rule, or use the option Set default rule to deny all connections. The Show all rules and Delete a Rule functions are self-explanatory and are not explained here. The system diagram depicted in Figure 7 on page 22 shows several system components (UTC Fire & Security Network Receiver, ATS8000/ATS8300, and a computer with a web browser). Table 6 on page 23 summarizes the firewall rules for the sample system. To configure the firewall: 1. Add a rule so that the computer with the web browser can access the Universal Interface. Click Add a new rule in the Firewall Setup section of the Universal Interface menu. Type the IP address of the computer with the web browser, type port number 80, select TCP, select Accept, and click Submit.
AL-1809 / CA1809 / ATS1809 Universal Interface Installation and Programming Guide 13
Note: Setting the port number to 0 (zero), allows all port numbers. Repeat this step for any other computers requiring web access to the Universal Interface. 2. Add a rule for each CID station or ATS8000/ATS8300 management software station that requires access via the Universal Interface. Click Add a new rule in the Firewall Setup section of the Universal Interface menu. Type the IP address of the CID station or ATS8000/ATS8300 management software station, type port number 3001, select UDP, select Accept, and click Submit. Note: Setting the port number to 0 (zero), allows all port numbers. Repeat this step for each CID station or ATS8000/ATS8300 management software station that requires access via the Universal Interface. 3. Add a rule to enable a ping test, if required. Click Add a new rule in the Firewall Setup section of the Universal Interface menu. Type the IP address of the computer from which you want to perform a ping test, select ICMP, select Accept, and click Submit. We recommend that ICMP is normally disabled, and only used temporarily for testing. 4. Click Set default rule to deny all connections in the Firewall Setup section of the Universal Interface menu to exclude any other connections than the ones that you created rules for, and click Submit. Notes The Universal Interface uses a mechanism (Network Probing) where it can transmit a message using TCP port 22222 to check if a network is present (if enabled, see Network Setup > Network Probing). It will try to send this message to every central station programmed. The first to return an answer (Acknowledge or Reject) will stop further testing until the next test (12 second intervals). The usage of the firewall should be limited, as routers and firewalls in normal cases already provide the same security levels and are managed and updated by IT departments. If the PC at the receiving end has a firewall running (like Windows XP firewall) this also requires to be setup such that the ports are opened.
Email/TFTP parameters
As an alternative to connecting a printer to the Computer & Printer Interface (fitted to the control panel) and printing events, you can program the Universal Interface to output the printer events as data files and to send the files to email addresses or to a TFTP (Trivial File Transfer Protocol) server address. Note: Setting up email addresses, email servers, or TFTP servers is not described in this document.
14
To configure Email/TFTP: 1. Click Email/TFTP Parameters in the Network Setup section of the Universal Interface menu. 2. To use email, type at least one email address. Use additional email addresses if you want to send email to more than one recipient. Leave all email addresses blank if you do not want to send email. 3. Type the IP address for the mail server or TFTP (Trivial File Transfer Protocol) server, as required. Leave the server address blank if you do not want to send email or TFTP. 4. Type the Maximum number of events before sending to use the number of logged events as a trigger for sending email or TFTP. The value 0 (zero) disables this function. In addition to using a value greater than zero to trigger email or TFTP, you can also schedule email or TFTP by using the time settings, below. 5. Use the Time to send scheduled email fields in hours, minutes, and AM / PM to schedule daily email or TFTP transmissions. If used in conjunction with a Maximum number of events before sending value, the scheduling function will send email or TFTP even if the number of logged events has not reached the specified (non-zero) value. 6. When finished programming the required email or TFTP options, click Submit. Note: When finished programming the Universal Interface, click Restart Communications in the Utilities section of the main menu to update the system data.
15
The heartbeat interval defines the interval between heartbeats in seconds. 0255 seconds are valid. Note: The heartbeats in this case are sent by the Universal Interface to the UTC Fire & Security Network Receiver. If the heartbeat fails, an alarm event is created at the Network Receiver end. 5. Select the Network Receiver version. Version V1.9.4 (or higher) is recommended. Network Receiver versions V1.9.4 and higher are backwards compatible (auto-detect) with all existing formats. 6. When finished programming the required Network Receiver options, click Submit. Note: When finished programming the Universal Interface, click Restart Communications in the Utilities section of the main menu to update the system data.
Message format
Messages sent from the security panel to the monitoring station contain the UTC Fire & Security Network Receiver number, line number, account code/circuit number (normally four digits), and the event message. The format is: Rrrr Llll AAAA Eeee XX Cccc where: rrr is a Network Receiver number* lll is a line number* AAAA is a four-digit account code/circuit* Eeee XX Cxxx is an event message.
16
17
Reference section
Additional programming
Some of the items that you programmed in the Universal Interface as a result of following the procedures in this manual also need to be programmed in the ATS panel using an LCD RAS, and in other applications such as the management software and/or the central station software (as applicable). The following sections list the items that need to be programmed in addition to the Universal Interface programming. Refer to the programming instructions for the management software and/or the central station software (as applicable) for complete details. If central station reporting is used The following items must be programmed for each central station via RAS menu 19-14: Reporting format - CID Large events for SecureStream; CID, SIA, or XSIA for UTC Fire & Security Network Receiver. System and area account numbers (these items are not programmed via the Universal Interface).
The following items must be programmed for each central station via the central station software: CID Large events for SecureStream; CID, SIA, or XSIA for UTC Fire & Security Network Receiver. ATS panel security password. Protocol, data type, event type, and encryption type as required (refer to Table 2 on page 11). Encryption key (special rules apply for SecureStream, refer to the SecureStream manual).
If ATS8000/ATS8300 management software is used The following items must be programmed in ATS8000/ATS8300 for the ATS panel: ATS panels IP address (the Universals assigned IP address is not used for this purpose). Encryption key (if used). ATS panel physical (computer) address (requires a unique number for every panel in one system). ATS panel security password.
18
If ATS8000/ATS8300 management software and central station reporting are used In addition to the two lists (above), you must create a Central Station record ATS8000/ATS8300 for each of the ATS panels central stations (main, backup, and disaster), as applicable. Refer to ATS8000/ATS8300 on-line help for details. The items required to program a Central Station record in ATS8000/ATS8300 (including system and area account numbers) are not programmed via the Universal Interface.
Type the area 1 account number (four-digit number identifying an alarm area), and press Enter to confirm. Press Enter until the RAS screen displays Conn Type (default is PSTN). Press 4 to select Universal Interface, and then press Enter to confirm. Press Enter repeatedly to return to the menus top level where you can program any subsequent central stations.
* Temporarily means until the jumper on DEF is removed and the board is reset or powered has been applied again.
20
LED indication
The LEDs on the mainboard are listed in Table 3 below.
Table 3: Mainboard LEDs LED TX1 RX1 Color Red Green Description Indicates RS232 data transmission to Computer and Printer Interface Indicates RS232 data reception from Computer and Printer Interface
Refer to Figure 2 on page 2 for locations of LEDs. The LEDs on the SIMM are listed in Table 4 below
Table 4: SIMM LEDs LED LED2 Color Yellow Description Network speed: On: 100 Mbps Off: 10 Mbps LED3 Red Network mode: On: Full duplex Off: Half duplex LED4 LED1 Red Green On: Collision Network activity: On: Link activity present Off: No link activity present Flash: Network activity detected
21
Utility CPU Load System Uptime Flash ROM Version Reboot CPU
Function This displays the CPU and operating system parameters to assist when requesting technical support. Displays the time that it has been powered up in days, hours, minutes, and seconds. Use this to check the version of the software that the Universal Interface is running. Restarts the CPU (momentarily replacing the reset jumper performs the same task). The only data lost is the current information in the local event log. Allows upgrading the firmware inside the Universal Interface from a ROM image file.
10 204.18.63.19
11
204.18.63.15
1. UTC Fire & Security Network Receiver, Central Station 1 2. UTC Fire & Security Network Receiver, Central Station 2 3. ATS Control Panel 4. Universal Interface 5. Local Area Network 6. Gateway, IP 204.18.63.1
7. Router: Port: 9999 Port: 55555 8. External network 9. Computer and Printer Interface 10. PC with web-browser, used initially to program the Universal Interface during installation 11. Central Stations 4 to 10, ATS8000 or ATS8300
22
Table 6: Universal Interface settings for the sample network in Figure 7 Component IP Mask Gateway Central Station 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 204.18.63.15 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 UDP 3001 Event Computer [1] Network parameters 204.18.63.5 255.255.255.0 204.18.63.1 Network parameters 204.18.63.7 204.10.104.8 Protocol TCP TCP Port 9999 9999 Connect type Event Event Event type CID CID Encryption [1] [1]
[1] ATS8000/ATS8300 uses Twofish Encryption (optional). Network Receiver uses Triple DES encryption (required). Firewall Rules Rule Type Allow Allow Allow Allow Deny IP 204.18.63.7 204.10.104.8 204.18.63.15 204.18.63.19 All Protocol TCP TCP UDP TCP Port 0 0 0 80
23
Specifications
Software
Configuration Reporting format Mainly web browser after initial installation CID (Ademco Contact ID) CID, SIA, or XSIA using UTC Fire & Security Network Receiver Software upgrade paths Reporting options Upgradeable software obtainable from UTC Fire & Security Upload to ATS8000/ATS8300 software management site Reporting to up to three SecureStream Receivers for CID only or Reporting to one UTC Fire & Security Network Receiver for CID, SIA, or XSIA Reporting backup Encryption PSTN dialler backup from ATS panel for alarm events to central monitoring station 128-bit Twofish data encryption (SecureStream) Triple DES encryption (UTC Fire & Security Network Receiver)
Hardware
Dimensions Power supply Backup power Current consumption Onboard status indicators 50 x 170 mm 12 VDC direct from battery or other 12 VDC source. Directly connected to battery (deep discharge protected). 145 mA typical LED indicators for: Data connection from panel to Universal Interface Board size Ethernet link and activity. RS232 data transmit and receive.
RS232 connection from Universal Interface to Computer and Printer Interface board on ATS panel. UTC Fire & Security board size BB.
24
CPU reset via browser (Reboot CPU). Data reset to factory defaults via jumper (DEF). Restart Communications via browser.
25
Installation worksheet
Use this worksheet to record the details of the Universal Interface (UI), as applicable to the particular installation. Universal Interface parameters
Panel description UI user name Network: Static IP Address Net mask Net mask host bits Gateway address Panel location UI password From network administrator
Panel Setup
Event ACK interval Heartbeat Interval Panel physical (Computer) address Panel security password Twofish encryption key
Network Receiver
Receiver number Line number Heartbeat Interval
26
Email/TFTP Parameters
Email address 1 Email address 2 Email address 3 Server IP address Max number of events Time to send email Network Probing
Firewall parameters
Default firewall rule Individual firewall rules (up to 20 permitted) Number IP address 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Port Protocol Rule Type
27
28