Documente Academic
Documente Profesional
Documente Cultură
12-41
This section describes how to connect the PanelView 300 Micro terminal. Refer to the following topics in this section: RS-232 communications port Connecting to a MicroLogix Controller Connecting to a SLC, PLC-5, ControlLogix, MicroLogix, CompactLogix, or FlexLogix Controller Connecting to a DH-485 Network Connecting to a DeviceNet Network Connecting to a personal computer
1761-CBL-HM02 2711-CBL-HMxx
1761-CBL-AM00
Publication 2711-UM014E-EN-P
12-42
Terminal Connections
1761-CBL-PM02 2711-CBL-PMxx
ControlLogix Module
Cable, Catalog No. 1761-CBL-AP00, Series C (.5 m, 1.5ft) Cable, Catalog No. 1761-CBL-PM02, Series C (2 m, 6.5 ft) Cable, Catalog No. 2711-CBL-PM05, Series C (5m, 15 ft) Cable, Catalog No. 2711-CBL-PM10, Series C (10m, 30ft) Cable Connector Pin # 1 24V 2 GND 3 RTS 6 CTS 5 DCD 4 RXD 7 TXD 8 GND Cable Connector Pin # 9 RI 5 GND 7 RTS 8 CTS 1 DCD 2 RXD 3 TXD 4 DTR 6 DSR
Publication 2711-UM014E-EN-P
Terminal Connections
12-43
1761-CBL-AP00 1761-CBL-AM00 RS-232 Communications Port (to Port 1) (to Port 2) 1 2 Cable, Catalog No. 1761-CBL-AM00, Series C (.5 m, 1.5ft) 5 3 Cable, Catalog No. 1761-CBL-HM02, Series C (2 m, 6.5 ft) 4 Cable, Catalog No. 2711-CBL-HM05, Series C (5m, 15 ft) Cable, Catalog No. 2711-CBL-HM10, Series C (10m, 30ft) 8 7 6 Cable, Catalog No. 1761-CBL-AP00, Series C (.5 m, 1.5ft) Cable, Catalog No. 1761-CBL-PM02, Series C (2 m, 6.5 ft) Cable, Catalog No. 2711-CBL-PM05, Series C (5m, 15 ft) Cable, Catalog No. 2711-CBL-PM10, Series C (10m, 30ft)
5 9 Port 1
1 6
2 5 4 8 7 6 Port 2
1 3
NE T
D V+
MOD
NODE
1761-CBL-HM02 2711-CBL-HMxx
TX /RX
1761-CBL-AM00 RS-232 Communications Port 1 2 5 4 8 7 6 3 Cable, Catalog No. 1761-CBL-AM00, Series C (.5 m, 1.5ft) Cable, Catalog No. 1761-CBL-HM02, Series C (2 m, 6.5 ft) Cable, Catalog No. 2711-CBL-HM05, Series C (5m, 15 ft) Cable, Catalog No. 2711-CBL-HM10, Series C (10m, 30ft) Cable Connector Cable Connector Pin # Pin # 1 24V 24V 1 2 GND GND 2 3 RTS RTS 3 6 CTS CTS 6 5 DCD DCD 5 4 RXD RXD 4 7 TXD TXD 7 8 GND GND 8 RS-232 Comm Port 2 5 4 8 7 6 1 3
Publication 2711-UM014E-EN-P
12-44
Terminal Connections
TIP
Applications for the PanelView 300 Micro terminal are developed using PanelBuilder32 Software (Catalog No. 2711-ND3, V3.60 or later).
RS-232 Communications Port 1 2 Cable, Catalog No. 1761-CBL-PM02, Series C (2 m, 6.5 ft) Cable, Catalog No. 2711-CBL-PM05, Series C (5m, 15 ft) 5 3 Cable, Catalog No. 2711-CBL-PM10, Series C (10m, 30ft) 4 8 7 6 Cable Connector Pin # 24V 1 GND 2 RTS 3 CTS 6 DCD 5 RXD 4 TXD 7 GND 8 Cable Connector Pin # 9 RI 5 GND 7 RTS 8 CTS 1 DCD 2 RXD 3 TXD 4 DTR 6 DSR
RS-232 Connector 5 1
Refer to the PanelBuilder32 Software user manual for application download instructions. Heres a short summary of the methods that can be used to transfer files to a PanelView 300 Micro:
Publication 2711-UM014E-EN-P