Sunteți pe pagina 1din 8

30 BAR. DIA. 40 30 BAR. DIA.

CONSTRUCTION NOTES
CONSTRUCTION NOTES ARE SUPPLEMENTAL TO AND FORM PART OF THE PLANS, C. CONCRETE SLABS F. CONCRETE COLUMNS & PEDESTALS I. CONCRETE SLAB OPENINGS

D/3 D/3
DRAWINGS & SPECIFICATIONS. WHERE DETAILS OR REQUIREMENTS ARE NOT
COVERED BY THE PLANS OR SPECIFICATIONS, THESE GENERAL CONSTRUCTION 1. ALL SLAB REINFORCEMENT SHALL BE 20mm CLEAR MINIMUM FROM BOTTOM AND FROM 1. OTHERWISE SPECIFIED, OPENINGS ON SUSPENDED SLABS SHALL HAVE ADDITIONAL

D/3
1. FOR ALL TIED COLUMNS AND PEDESTALS, PROVIDE EXTRA 4 SETS OF TIES AT 100 mm O.C.

D
NOTES SHALL BE USED INSOFAR AS THEY ARE APPLICABLE TO SATISFY REQUIRE- TOP OF SLAB. FOR COLUMN REINFORCEMENTS JUST ABOVE THE FLOOR, JUST BELOW THE GIRDER AND REINFORCEMENT AS SHOWN BELOW:
MENTS OF GOOD CONSTRUCTION PRACTICE. IN CASE OF QUESTIONS ARISING FROM 2. UNLESS OTHERWISE DETAILED, IN CONTINUOUS SLABS HAVING SAME REINFORCEMENT AT CONSTRUCTION JOINTS.
THE INTERPRETATION OF OR CONFLICT WITH OTHER DOCUMENTS, THE ATTENTION RUNNING IN ONE DIRECTION, REINFORCING BARS SHALL BE BENT UP, EXTENDED, OR CUT 12mmØ x 1.00 m LONG DIAGONAL BAR
OF THE OWNER/ENGINEERS MUST BE CALLED IN WRITING. 2. COLUMN AND PEDESTAL TIES SHALL BE PROTECTED BY A COVERING OF CONCRETE CAST @ MID-DEPTH OF SLAB AT ALL CORNERS
AS FOLLOWS:
MONOLITHICALLY WITH THE CORE WITH MINIMUM THICKNESS OF 38 mm AND NOT LESS THAN

(TYPICAL)
MAIN REINFORCEMENTS WHERE JOINT IS AT POINT OF

400mm
A. GENERAL L1/3 L1/3 L2/4 L2/4 L3/4 L3/2 1-1/3 TIMES MAXIMUM SIZE OF COARSE AGGREGATE. TO BE CONTINUOUS STRESS, PROVIDE SHEAR RODS
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS (TOP & BOT. BARS) BEAM WITH ENGINEERS APPROVAL
OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET G. BEAMS AND GIRDERS LONGITUDINAL TRIMMER BAR 25
SPECIAL CONDITIONS. (TOP & BOTTOM)

VERIFY
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL 1. TYPICAL BAR BENDING AND CUTTING DETAILS FOR BEAMS AND GIRDERS SHALL BE AS SHOWN

t/3 t/3
STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED IN FIGURE BELOW:

t/3
FOR ENGINEER'S APPROVAL BEFORE FABRICATION.
L1/5 L2/5 L2/5 L3/5 L3/3 2/3 L4 L1/5 L1/4 L2/4 L2/4 L3/4 L3/4 3/4 EMBEDMENT LENGTH
TRANSVERSE TRIMMER BAR
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN. LENGTH IN TABLE 'A' (TOP & BOTTOM)
L1 L2 L3 L4 30mm CLEAR
CHECK WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE SEE TABLE 'A' 10mmØ x 1m LONG @ 300 O.C.
SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE. INDICATED DIMENSIONS SHALL (ALL AROUND) OPENING NOTE:
FOR LENGTH
GOVERN AND DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION OF EMBEDMENT OMIT TRIMMER BARS WHERE MAIN REINFORCEMENTS
PURPOSES. 3. IF SLABS ARE REINFORCED BOTHWAYS, BARS ALONG THE SHORTER SPAN SHALL BE PLACED OPENING IS FRAMED BY BEAM. TO BE CONTINUOUS
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE BELOW THOSE ALONG THE LONG SPAN AT THE CENTER AND OVER AT THE SUPPORTS. FOR
SLAB
SHORINGS AND BRACING TO THE STRUCTURE FOR ALL LOADS THAT MAYBE THE REINFORCING BARS NEAR THE SUPPORTS, THE SPACING OF THE BARS AT THE COLUMN
IMPOSED DURING CONSTRUCTION. STRIPS SHALL BE APPROXIMATELY ONE AND A HALF (1-1/2) THAT IN THE MIDDLE STRIPS BUT SEE TABLE 'B' WHEN COUNTED FOR
IN NO CASE GREATER THAN TWO AND A HALF (2-1/2) TIMES THE SLAB THICKNESS NOR 450mm. FOR LENGTH COMPRESSION EXTEND IN TWO WAY SLABS, EXTEND TYPICAL SLAB AND BEAM
5. IN REFERENCE TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR OF EMBEDMENT BARS UP TO BEAM SUPPORT
DEPRESSIONS IN FLOOR SLABS, OPENINGS IN WALLS AND SLABS, INTERIOR 4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN TENSION
L1 L2 L3 20xDIA. BEYOND OPPOSITE
FACE OF SUPPORT
CONSTRUCTION JOINT DETAIL
PARTITIONS, LOCATION OF DRAINS, ETC. AND SHALL NOT BE LESS THAN 0.0025xBT, AND AS FOLLOWS: EXTERIOR COLUMN INTERIOR COLUMN EXTERIOR GIRDER
SUPPORT SUPPORT SUPPORT
6. IN CASE OF DISCREPANCIES AS TO THE LAYOUT DIMENSIONS AND ELEVATIONS
BETWEEN THE STRUCTURAL PLANS AND OTHER DRAWINGS. THE CONTRACTOR
SEE TABLE 'B' FOR
LENGTH OF LAPPED SPLICE
J. EMBEDDED PIPES IN CONCRETE
SCHEDULE OF MINIMUM SLAB REINFORCEMENT
SHALL NOTIFY BOTH THE STRUCTURAL ENGINEERS AND THE OWNER'S REPRESENT-
ATIVE OR SITE ENGINER IN WRITING BEFORE PROCEEDING WITH AFFECTED WORK.
2. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN 1. ALL EMBEDDED PIPES FOR UTILITIES, ETC. SHALL BE MAXIMUM 100mm DIAMETER SINGLE 40 BAR DIA 40 BAR DIA
THICKNESS MINIMUM TEMPERATURE BARS ACCORDANCE WITH TABLE-A OR B. RIGID GALVANIZED IRON PIPE UNLESS OTHERWISE SPECIFIED OR APPROVED IN WRITING

BEAM
BY THE STRUCTURAL ENGINEER.

DEPRESSION
100 mm 10mmØ @ 275mm O.C. EACH WAY
B. CONCRETE AND REINFORCEMENT TABLE - A

t=FOR SLAB

VERIFY
2. SUCH PIPES WHEN SO EMBEDDED SHALL NOT TAKE UP MORE THAN FOUR (4) PERCENT
112.5 mm 10mmØ @ 238mm O.C. EACH WAY TENSION BARS EMBEDMENT LENGTH & LAP SPLICES (IN CENTIMETERS) OF THE GROSS AREA OF THE CONCRETE MEMBER.
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING
125 mm 10mmØ @ 212mm O.C. EACH WAY

D=FOR
CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318) FOR REINFORCED CONCRETE 3. TYPICAL DETAIL OF PIPE SLEEVES THROUGH CONCRETE IS SHOWN AS FOLLOWS:
BAR SIZES fc'= 20.7 MPa (3000 psi) fc' = 17.2 MPa (2500 psi)
& STRUCTURAL STEEL WORK SHALL CONFORM WITH THE LATEST EDITION OF THE 137.5 mm 10mmØ @ 188mm O.C. EACH WAY (mm) EMBEDMENT LAPPED EMBEDMENT LAPPED
A.I.S.C. SPECIFICATIONS IN SO FAR AS THEY DO NOT CONFLICT WITH THE REQUIRE-
150 mm 10mmØ @ 175mm O.C. EACH WAY
MENTS OF THE NATIONAL STRUCTURAL CODE FOR BUILDINGS AND LOCAL CODES. 30 30 30 30 STIRRUPS
Ø10
5. UNLESS OTHERWISE NOTED IN THE PLANS, ALL BEDDED SLABS SHALL BE REINFORCED WITH Ø12 30 36 30 30
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE DIAGONAL
10mmØ REBAR AT 250 mm O.C. EACH WAYAT CENTER OF SLAB, AND CONSTRUCTION JOINTS HORIZONTAL
2t=FOR SLAB
END OF TWENTY EIGHT (28) DAYS WITH CORRESPONDING MAXIMUM SIZE
AGGREGATE AND SLUMPS AS FOLLOWS:
FOR SAME SHALL NOT BE MORE THAN 8 METERS APART. Ø16 36 45 30 43
D=FOR BEAM
6. PROVIDE EXTRA REINFORCEMENTS FOR CORNER SLAB (TWO ADJACENT DISCONTINUOUS Ø20 36 55 39 61
EDGES AS SHOWN BELOW). 40 BAR DIA.

a
LOCATION 28 DAYS STRENGTH MAX. AGGREGATE SIZE MAX. SLUMP Ø22 52.5 62.5 57.5 65
(MIN)
Ø25 56 95 62 105
FOUNDATION & 3000 psi (20.7 MPa) 5 in. (130 mm)
1 in. (25 mm) Ø28 71 121 77 131
RETAINING WALLS
5-10mmØ BOTTOM BARS SP. @ 200mm O.C.
TYPICAL DETAIL FOR BEAM
Ø32 93 158 101 172
COLUMNS & BEAMS
3000 psi (20.7 MPa) 3/4 in. (19 mm) 5 in. (130 mm) OR SLAB CHANGE SOFFIT
ON GROUND Ø36 151 179 128 218 VERTICAL STIRRUPS
SUSPENDED BEAMS 3000 psi (20.7 MPa) 3/4 in. (19 mm) 5 in. (130 mm) SLEEVE
TABLE - B b 12mm THK. EXPANSION JOINT
SUSPENDED SLABS 3000 psi (20.7 MPa) 3/8 in. (10 mm) 5 in. (130 mm)
5-10mmØ TOP BARS SP. @ 200mm O.C. COMPRESSION BARS EMBEDMENT LENGTH & LAP SPLICES (IN CM) MAIN REINFORCEMENT WITH MASTIC FILLER
CURBS AND SLAB 2500 psi (17.2 MPa) 4 in. (100 mm) 7. ON SLABS ON GRADE:
1 in. (25 mm)
ON GRADE BAR SIZES fc'= 20.7 MPa (3000 psi) fc' = 17.2 MPa (2500 psi)
a. ALL SLABS ON GRADE SHALL BE DESIGNED WITH A MINIMUM WATER CEMENT RATIO OF (mm)
3/8 in. (10 mm) 5 in. (130 mm)

t
MOULDINGS 3000 psi (20.7 MPa) EMBEDMENT LAPPED EMBEDMENT LAPPED

t OR 1/4D
OF 0.42. ANY DECREASE IN WORKABILITY SHALL BE COMPENSATED USING A PLASTICIZER.

(DOWEL)
400
b. ALL SLOPES SHALL BE POURED INTEGRAL WITH SLAB OVERLAYS & TOPPING SHALL NOT Ø10 20 30 20 30
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615. USE GRADE40 FOR Ø16mm BE ALLOWED UNLESS APPROVED OR SPECIFIED BY ENGINEER.
& SMALLER, GRADE 60 FOR REBARS Ø20mm & BIGGER. Ø12 20 30 21 34 1-Ø16mm VERT. BARS

D
c. CONTINUOUS WET CURING OF CONCRETE BY PONDING SHALL BE DONE FOR AT LEAST
ALL BARS 12mmØ AND BIGGER SHALL BE DEFORMED. BARS SMALLER THAN 12mmØ
14 DAYS UNLESS OTHERWISE SPECIFIED. Ø16 23 32.5 26 42.5 CHB WALL
MAY BE PLAIN BARS.
4. BARS OF REINFORCED CONCRETE EXPOSED TO THE WEATHER SHALL PREFERABLE BE Ø20 28 37.5 31 50 FOR SIZE AND SPACING
PROTECTED AT LEAST 38mm AND IN NO CASE LESS THAN 25mm CONCRETE COVER. THIS D. FOUNDATION AND FOOTINGS Ø22 25 45 27.5 57.5 SLEEVES FOR UTILITY
OF HOR. & VERT. BARS
PROVISION MAY BE WAIVED WHEN ADEQUATE WATERPROOFING IS PROVIDED BUT SHALL SEE CONSTRUCTION NOTES
1. FOOTINGS WERE DESIGNED FOR A SOIL BEARING CAPACITY OF 2000 psf FOR AN EMBEDMENT PIPES MAX. 1/3D
IN NO CASE BE LESS THAN 20mm. Ø25 37 51 41 67.5
OF 2 METERS & 1470 psf FOR AN EMBEDMENT OF 1.5 METERS OR LESS.
Ø28 42 57.5 77 75 PROVIDE 3-Ø10 EXTRA STIRR. CORNER WALL
5. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE 2. FOOTINGS SHALL REST ON NATURAL SOIL 1.50 METERS BELOW GRADE LINE, UNLESS
Ø32 46 64 52 85 EACH SIDE OF SLEEVES.
DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS OTHERWISE INDICATED BY THE ENGINEER. NO PART OF THE FOUNDATION SHALL REST
OTHERWISE SHOWN OR NOTED. ON FILL UNLESS REPLACED WITH 1.0 m DEEP WELL-COMPACTED CRUSHED ROCK FILL..
Ø36 51 72 - - 12mm THK. EXPANSION JOINT
COMPACTION OF ALL SUBGRADE SHALL BE AT 95% OF MDD BASED ON ASTM D698. REINFORCING BAR FOR SLEEVES
6. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS. WITH MASTIC FILLER
3. IF BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE
3. THE CONTRACTOR SHALL NOTIFY IN WRITING THE ENGINEER AFTER FOOTING
FARTHER FACE OF THE WALL SHALL NOT BE LESS THAN 25mm. EMDEDMENT LENGTH SHALL OPENING REINFORCING BARS
SUSPENDED SLABS 3/4 in. (19mm) EXCAVATION HAS BEEN COMPLETED AND PRIOR TO CONCRETING TO CONFIRM
BE AS SHOWN IN TABLE-A & TABLE-B ACCORDINGLY. DIAMETER HORIZONTAL STIRRUP
1 1/2 in. (38mm) THE DESIGN SOIL BEARING CAPACITY AND IF ACTUAL SOIL PROPERTY APPEARS DIAGONAL VERTICAL
SLAB ON GRADE WEAKER THAN ASSUMED.

(DOWEL)
4. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mm DIAMETER BAR
Ø< 2 - Ø12 2 - Ø12

400
WALLS ABOVE GRADE 1 in. (25mm) = 100 - -
4. THE CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO DEVISE & IMPLEMENT SEPARATORS SPACED ABOUT 90 cm ON CENTER. IN NO CASE SHALL THERE BE LESS THAN
BEAM STIRRUPS AND COLUMN TIES 1 1/2 in. (38mm) EXCAVATION PROCEDURES THAT WILL ENSURE SAFETY OF LIFE & PROPERTY. TWO (2) SEPARATORS BETWEEN LAYERS OF BARS. < 2 - Ø12 2 - Ø12 2 - Ø12 Ø12 - @50
150 < Ø = 150 1-Ø16mm VERT. BARS
WHERE CONCRETE IS EXPOSED TO EARTH CONTRACTOR SHALL ENSURE THAT ALL EXISTING STRUCTURES ARE PROPERLY AND <
2 in. (50mm) 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS SHALL BE 18.75mm CLEAR FOR 150 < Ø = 200 2 - Ø16 2 - Ø16 2 - Ø16 Ø12 - @50
BUT POURED AGAINST FORMS ADEQUATELY SUPPORTED AGAINST SETTLEMENT OR MOVEMENT DURING CONSTRUCTION.
JOISTS & 37.50mm CLEAR FOR BEAMS AND GIRDERS.
5. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 75 mm CLEAR < 250
200< Ø = 2 - Ø20 2 - Ø16 2 - Ø16 Ø12 - @50
WHERE CONCRETE IS DEPOSITED FOR SIZE AND SPACING
3 in (75mm) FOR CONCRETE DEPOSITED AGAINST THE GROUND AND 50 mm CLEAR IF DEPOSITED 6. GENERALLY NO SPLICE SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES
DIRECTLY AGAINST EARTH OF HOR. & VERT. BARS
AGAINST A FORMWORK. OCCUR. SPLICES WHERE SO PERMITTED SHALL BE AS INDICATED IN TABLES A & B. WELDED SPLICES SEE CONSTRUCTION NOTES
SHALL DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR.
8. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY
POSITIONED AND SECURED IN PLACE PRIOR TO PLACING OF CONCRETE.
6. FILL AND SUBGRADE UNDER SLABS AND FOOTINGS SHALL BE COMPACTED TO A MINIMUM
95% OF MDD (MAXIMUM DRY DENSITY) BASED ON ASTM D698. NO MORE THAN 50% OF THE BARS AT ANY ONE SECTION SHALL BE ALLOWED TO BE SPLICED THEREIN.
K. STRUCTURAL STEEL CHB WALL

1. ALL STRUCTURAL STEEL TO BE USED FOR FABRICATION AND ERECTION SHALL


9. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, H. LINTEL BEAMS IN CHB WALLS COMPLY WITH ALL THE PERTINENT PROVISIONS OF AISC. INTERSECTION WALL
TOOLS, EQUIPMENTS AND MECHANICAL BASES THAT ARE REQUIRED BY THE
ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. E. MASONRY AND CONCRETE BLOCKS 1. REINFORCEMENTS FOR CONCRETE LINTEL BEAMS FOR OPENINGS (DOORS & WINDOWS) SHALL BE 2. ALL STRUCTURAL STEEL SHAPES & PLATES SHALL CONFORM TO STD. REQUIREMENTS
1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT AS FOLLOWS: OF AISC FOR ASTM A36 STEEL. MIN. YIELD STRENGTH = 248 MPa OR 36000 psi. DOWEL BARS TO MATCH
10. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CHB HOR. BARS
NOT TO EXCEED 80 PCF. 3. ALL COLD FORMED STEEL SHAPES SHALL CONFORM TO STD. REQUIREMENTS
CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP, LINTEL IN BLOCK WALLS (PER 100mm THICKNESS)
FOR LOAD BEARING TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE OF AISC FOR JIS G3141 SPCC. MIN. YIELD STRENGTH = 227 MPa OR 33000 psi. 12mm THK. EXPANSION JOINT
FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. WITH MASTIC FILLER
STRENGTH OF 6.90 MPa SHALL BE DEVELOPED. CLEAR SPAN 'L' TOTAL LENGTH MIN. fc' HEIGHT OF REINFORCEMENT
4. ALL PIPES & TUBES SHALL CONFORM TO STD. REQUIREMENTS OF ASTM A53.
11. STRIPPING OF FORMS AND SHORES SHALL BE DONE AFTER A MINIMUM AMOUNT OF (m) (L + 0.40 , m) MPa LINTEL (cm) BOTTOM
2. PROVIDE 1-Ø10mm VERTICAL BAR AT CORNERS, INTERSECTIONS, END OF TOP MIN. YIELD STRENGTH = 248 MPa OR 36000 psi.
LOCATION TIME WALLS AND EACH SIDE OF OPENINGS. 1.20 1.80 13.80 20 1-10mmØ 1-10mmØ
5. ALL SHOP AND FIELD WELDS SHALL CONFORM WITH AWS STRUCTURAL WELD CODE D1-1.
3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200 mm) ON EACH SIDE OF 1.50 1.90 13.80 20 1-10mmØ 1-10mmØ USE E60XX ELECTRODE. WELDING SHALL BE PERFORMED BY QUALIFIED WELDERS.
FOUNDATION 24 HRS.
MASONRY WALL OPENING. 1.80 2.20 13.80 20 1-10mmØ 1-10mmØ 6. ALL BOLTS, NUTS AND WASHERS SHALL BE HIGH-STRENGTH & CONFORM TO A307
SUSPENDED SLABS EXCEPT WHEN
8 DAYS 4. MASONRY WALL REINFORCEMENTS SHALL BE AS FOLLOWS, UNLESS NOTED: 2.10 2.50 17.20 20 1-16mmØ 1-10mmØ OR A325 UNLESS OTHERWISE INDICATED. ANCHOR BOLTS SHALL LIKEWISE BE OF
ADDITIONAL LOADS ARE IMPOSED R.C. COLUMN OR WALL
2.40 2.80 17.20 20 1-16mmØ 1-10mmØ EQUAL STRENGTH AS A325 BOLT OF THE SAME SIZE .
WALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT INTERSECTING R.C. COLUMN OR WALL
WALLS 18 HRS.
8" (200 mm) 2.70 3.10 17.20 20 1-20mmØ 1-10mmØ
Ø12 @ 400 mm Ø10 @ 600 mm (3 LAYERS)
BEAMS 14 DAYS 3.00 3.40 17.20 30 1-16mmØ 1-10mmØ
6" (150 mm) Ø10 @ 600 mm Ø10 @ 600 mm (3 LAYERS) 1-Ø16mm VERT. BARS
COLUMNS 3 DAYS 3.30 3.70 17.20 30 1-16mmØ 1-10mmØ
4" (100 mm) Ø10 @ 600 mm Ø10 @ 600 mm (3 LAYERS)
12. ON LAP SPLICE AND HOOKS: 3.60 4.00 17.20 30 1-16mmØ 1-10mmØ
a. ALL BARS FOR BEAMS AND COLUMNS SHALL BE LAPPED WITH A MIN. LENGTH 5. REINFORCING BARS SHALL BE LAPPED WITH A MINIMUM OF 30 BAR DIAMETERS
NOTE : USE 10mmØ STIRRUPS SPACED @ 200mm O.C.
OF 30 x BAR DIAMETER. WHERE SPLICED DOWELS FROM CONCRETE FOOTINGS OR SLABS SHALL EXTEND INTO
b. ALL BARS FOR SUSPENDED SLABS SHALLE BE SPLICED WITH A MIN. LENGTH THE BLOCK WALL AT A MINIMUM OF 30 BAR DIAMETERS. REBARS TO BE TIED PROPERLY 'L' 'L'
WITH G.I. WIRES. FOR SIZE AND SPACING
OF 40 x BAR DIAMETER.
c. NO MORE THAN 50% OF THE BARS SHALL BE SPLICED WITHIN THE REQUIRED 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY
0.20 0.20 0.20 0.20 OF HOR. & VERT. BARS
LAP LENGTH. FILLED WITH CONCRETE GROUT (REFER TO SPECIFICATIONS ). SEE CONSTRUCTION NOTES
d. 90° HOOKS WITH 12 x BAR DIAMETER EXTENSION (SPECIFICALLY FOR BEAMS) 7. WELD HORIZONTAL BARS FOR CHB WALL TO STEEL COLUMNS WHERE APPLICABLE. OPENING OR END WALL
SHALL BE ANCHORED INTO THE FAR FACE OF THE COLUMN.
13. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION,
REHANDLING OR FLOWING. ADEQUATE VIBRATION OR APPROVED EQUAL METHOD
TYPICAL MASONRY WALL
10mmØ BAR AROUND
SHALL BE DONE DURING DEPOSITION OF CONCRETE.
12mmØ BARS ON SIDES WINDOW OPENING (TYP.)
OPENING CONNECTION DETAILS
14. SAMPLING FOR COMPRESSIVE STRENGTH TESTS SHALL BE MADE IN ACCORDANCE OPENING
OF DOOR OPENING
WITH SPECIFICATIONS.

FIN. FLR.

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-1
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 01 08
B E B E B E
A C D A C D A C D
4000 4000 4000 4000 4000 4000

3375 3375 3375 3375 3375 3375


RB RB

RBCB

RBCB
FTB FTB B1 B1 RB RB
4 C1 C1 C1
4 4
S1 S2
WF-2

WF-2
F2 F2 F2
B2 B2
WF-2 WF-2
4000

4000

4000
FTB

FTB

FTB

RB

RB

RB
B1

B1

B1
S3 S4 S5 S6

B3

B3
FTB FTB B1 B1 RB RB
3 C1 C1 C1
3 3
1325

1325

1325
FTB

FTB

RB

RB
B1

B1
F1
S7 S8
10mØ DRSB @ 300mm O.C.
2 2 2
FTB

RB
BOTH WAYS FOR ALL SLABS

B3

B1

B3
CF1 C1 CF1 ON FILL CF1 C1

RBCB
1675

1675

1675

RBCB
CB
CB
FTB

FTB

FTB FTB B1 B1 RB RB
1 C1 C1 C1
1 1

RBCB
RBCB
RBCB
CB
S9 S10

CB
CB
F1 F1 F1
B3 B3 RB B3

FOUNDATION PLAN 2ND FLOOR FRAMING PLAN ROOF FRAMING PLAN


SCALE 1:100 SCALE 1:100 SCALE 1:100

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-2
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 02 08
FOOTING SECTION PLAN VIEW
SCALE DNTS SCALE DNTS

SCHEDULE OF REINFORCED CONCRETE BEAMS @ FOUNDATION LEVEL


BEAM SECTION LONGITUDINAL REINFORCEMENTS
MARK BAR Ø STIRRUPS
WIDTH DEPTH LOCATION LEFT END MIDSPAN RIGHT END
(B) (H) SECTION SECTION SECTION
TOP BARS 3 - 16mmØ 2 - 16mmØ 3 - 16mmØ
FTB 200mm 400mm 10mm :1@50mm 12@100mm 5@150mm REST @ 250mm O.C. TO C.L.
BOTTOM BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ

SEE CONSTRUCTION NOTES


FOR MASONRY WALL REIN-
FORCEMENTS (TYPICAL)
COMBINE DOWEL TO MATCH
CHB VERT. BARS
DOWEL TO MATCH
CHB VERT. BARS

FOOTING SECTION PLAN VIEW

(DOWEL)
FFL (TYP) (TYP) WHERE SLAB
SCALE DNTS SCALE DNTS DEPRESSION OCCURS
DOWEL BARS TO MATCH
CHB VERT. BARS
FIN. FLR. LVL.
NGL

SCHEDULE OF ISOLATED FOOTING REINFORCEMENT 30 BAR


DIAMETER

DIMENSION
X Y 6-Ø10 BARS (AS SHOWN)
FOOTING THICKNESS RSB SIZE REMARKS REMARKS
LENGTH DIRECTION DIRECTION 3-Ø10 BOT. BARS
MARK WIDTH Ø12 BOT. BARS @ 300 O.C.

@ DEPTH OF 1.50m
F1 1700 1700 350 16mm 9-16mm 9-16mm ISOLATED FOOTING Ø12 BOT. BARS
FROM N.G.L. @ 300 O.C. WF-2 WF-3
WF-1 AT INTERIOR WALLS WITH
@ DEPTH OF 1.50m
F2 1800 2400 450 16mm 17-16mm 12-16mm ISOLATED FOOTING AT EDGE / PERIMETER CHB WALL AT INTERIOR CHB WALLS SLAB ELEVATION DIFFERENCE
FROM N.G.L.

WALL FOOTING DETAILS


SCHEDULE OF COMBINE FOOTING REINFORCEMENT SCALE NTS
DIMENSION
X Y
FOOTING THICKNESS LOCATION REMARKS REMARKS
LENGTH DIRECTION DIRECTION
MARK WIDTH

TOP 16-16mm 7-16mm @ DEPTH OF 1.50m


CF1 1500 2000 300 COMBINE FOOTING FROM N.G.L.
BOTTOM 16-16mm 7-16mm

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA PINE'S RESIDENCE


2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-3
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
LAKEWOOD
D.S. GARCIA,SUBD.
CABANATUAN
CABANATUAN
CITY N.E.
CITY N.E. 03 08
L/4
WALL REINFORCING AT WALL REINFORCING WALL BASE REINFORCING
R.C. COLUMN AT CORNER AT INTERSECTION

LAT. TIES

0.165L

0.22LSPLICE 400

GIRDER TO COLUMN
CHB STIFFENER BEAM DETAILS SECTION STIFFENER COLUMN DETAILS
CONNECTION DETAIL ON CHB WALLS
SCALE NTS

COLUMN ELEVATION SHOWING


DOWELS AND TIES SPACING DETAILS
SCALE NTS

150mm THK. CONCRETE SLAB-ON-GRADE


FFL - 2F

2F - RF
F - FFL

10mmØ DRSB @ 300mm O.C. BOTH WAYS


C1

C1

C1

TOP OF SLAB

75
100 150
SIZE 250 mm x250 mm SIZE 250 mm x250 mm SIZE 250 mm x250 mm

VERT. BARS 8pcs - Ø16mm VERT. BARS 8pcs - Ø16mm VERT. BARS 8pcs - Ø16mm

CONF. REINF. 3 Sets - 6pcs - Ø10mm @ 75mm CONF. REINF. 3 Sets - 8pcs - Ø10mm @ 75mm CONF. REINF. 3 Sets - 7pcs - Ø10mm @ 75mm

JOINT REINF. 3 Sets - Ø10mm @ 100mm JOINT REINF. 3 Sets - Ø10mm @ 100mm JOINT REINF. 3 Sets - Ø10mm @ 100mm

3 Sets - Ø10mm @ 100mm 3 Sets - Ø10mm @ 100mm 3 Sets - Ø10mm @ 100mm


TIES / SPIRAL TIES / SPIRAL TIES / SPIRAL

SUBGRADE COMPACTED TO 95% MDD


BASED ON ASTM D-698
50mm THK. GRAVEL BED COMPACTED TO
95% MDD BASED ON ASTM D-698
SLAB ON GRADE DETAILS
SCALE NTS

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-4
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 04 08
ELEVATION

ELEVATION

SECTION SECTION SECTION OF 3 SETS STIRRUPS

TYPICAL DUCTILE MOMENT TYPICAL GRAVITY REINFORCED


FRAME BEAM DETAIL CONCRETE BEAM DETAIL
SCALE NTS SCALE NTS

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-5
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 05 08
SCHEDULE OF REINFORCED CONCRETE BEAMS @ 2NDLEVEL
BEAM SECTION LONGITUDINAL REINFORCEMENTS
MARK BAR Ø STIRRUPS TYPE
WIDTH DEPTH LOCATION LEFT END MIDSPAN RIGHT END
(B) (H) SECTION SECTION SECTION
TOP BARS 5 - 16mmØ 3 - 16mmØ 5 - 16mmØ
B1 200mm 400mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 3 - 16mmØ 5 - 16mmØ 3 - 16mmØ
TOP BARS 3 - 16mmØ 2 - 16mmØ 3 - 16mmØ
B2 200mm 350mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 2 - 16mmØ 3 - 16mmØ 2 - 16mmØ
TOP BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ
B3 200mm 350mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ
TOP BARS 4 - 16mmØ 4 - 16mmØ 4 - 16mmØ
CB 200mm 400mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ

SCHEDULE OF REINFORCED CONCRETE BEAMS @ ROOF LEVEL


TOP BARS 3 - 16mmØ 2 - 16mmØ 3 - 16mmØ
RB 200mm 350mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ
TOP BARS 3 - 16mmØ 3 - 16mmØ 3 - 16mmØ
RBCB 200mm 350mm 10mm :1@50mm 12@100mm 5@150mm REST @ 200mm O.C. TO C.L. A
BOTTOM BARS 2 - 16mmØ 2 - 16mmØ 2 - 16mmØ

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-6
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 06 08
SCHEDULE OF SLAB REINFORCEMENT
SLAB BOTTOM REINFORCEMENT TOP REINFORCEMENT
NUMBERS THK TYPE DISTRIBUTION
SHORT SPAN LONG SPAN SS CONT. LS CONT.
(BENT UP) (BENT UP)
S1 115 1-Way #10 @ 180 -- #10 @ 180 -- #10 @ 180

S2 115 1-Way #10 @ 180 -- #10 @ 180 -- #10 @ 180

S3 115 2-Way #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180

S4 115 2-Way #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180

S5 115 2-Way #10 @ 180 #10 @ 180 #10 @ 180 -- #10 @ 180

S6 115 2-Way #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180 #10 @ 180

S7 115 2-Way #10 @ 180 #10 @ 180 -- #10 @ 180 #10 @ 180

S8 115 2-Way #10 @ 180 #10 @ 180 -- #10 @ 180 #10 @ 180

S9 115 1-Way #10 @ 180 -- #10 @ 180 -- #10 @ 180

S10 115 1-Way #10 @ 180 -- #10 @ 180 -- #10 @ 180

L/4 Ld

L/4

L/4

250
400 400

STAIR DETAILS
SCALE NTS

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-7
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 07 08
FULLY WELD

TRUSS
2" x 4" x 3 16 " C - PURLINS BOTTOM CHORD

RAFTERS SPACED @ 500mm O.C.


PARAPET WALL 200mm x 250mm x
12mm
FLASHING

B E THK. BASE PLATE


4 - 12mm Ø x 350mm
LONG SPAN RIB TYPE
ANCHOR BOLT
A C D W/ NUT & WASHER
ROOF

B PLAN DOUBLE STAINLESS


GUTTER
S-1 1
4" BASE PLATE

12mm Ø BAR 3" DIA. PVC PIPE


ANCHOR BOLT DOWN SPOUT

CONCRETE BEAM METAL FURRING,


(SEE STRUCTURAL CEILING JOIST and
DETAILS) CEILING HANGER
4 AIR VENTILLATION

2" x 4" x 3 16 "


C - PURLINS

12mm Ø SAG ROD

A DETAILS
S-1
1
4" MS PLATE

3
TRUSS

TRUSS

TRUSS

TRUSS

TRUSS

TRUSS
2L 4 " x 3 21 " x 1 4"
ANGLE BAR

1 A
S-1

2L 2 21 " x 2 21 " x 1 4"


ANGLE BAR

HEIGHT
ROOF FRAMING PLAN B
S-1
800 1275
SCALE 1:100 LENGTH
TRUSS MEMBERS

TOP CHORD 2L 2 21" x 2 21 " x 41 "

TYPICAL TRUSS DETAILS BOTTOM CHORD 2L 2 21" x 2 21 " x 41 "

SCALE NTS WEB MEMBERS 2L 2 21" x 2 21 " x 41 "

KING POST 2L 2 21" x 2 21 " x 41 "

PROJECT TITLE : OWNER : SHEET NO. :

MARK CHRISTIAN D. ESGUERRA 2-STOREY DUPLEX RESIDENCE AAA PRIME PROPERTY MANAGEMENT INC S-8
CIVIL/STRUCTURAL ENGINEER
PRC REG NO.: 0164558 EXPIRATION.: MARCH 21, 1997 LOCATION : CAD BY : CHECKED BY : REVISION :
PTR NO.: 7387127
ISSUED AT: STA ROSA N.E.
DATE.: JANUARY 07, 2022
D.S. GARCIA, CABANATUAN CITY N.E. 08 08

S-ar putea să vă placă și