The COBAS TaqMan 48 instrument is a fully automated, closed-tube system that makes molecular testing practical for everyday lab use. This real-time PCR analyzer is compact and robust with a broad linear range, and integrates easily into your lab.
Features and benefits Real-time TaqMan PCR methodology provides unmatched accuracy, superior linear range, and the potential to run one test for quantitative and qualitative requirements Run sizes of 6 to 48 samples provide flexibility and maximum efficiency Two independently operating thermal cyclers with approximate run times of 90 to 120 minutes increases workflow flexibility and minimizes the need for multiple platforms AMPLILINK software is Windows driven for easy navigation, and provides the security of positive sample ID throughout the run, as well as enhanced LIS capabilities The utility channel adds flexibility and cost effectiveness by allowing the laboratory to run IVD and user-defined assays on one fast, easy, and accurate platform
Physical Dimensions Weight Technology Software Host Interfaces Printer Interfaces Data Station
18" x 30" x 20" (W x D x H) 121 lbs. Fully automated amplification and detection analyzer for homogenous 5' nuclease assays AMPLILINK software is a Windowsbased, LIS-compatible user interface that manages up to 3 COBAS TaqMan 48 instruments RS232 or LAN connections using ASTM protocol interface to the laboratory host computer LPT interface via parallel port or LAN for remote printing Custom-built PC supplied with the COBAS TaqMan 48 instrument; data station runs Microsoft Windows XP Professional operating system and AMPLILINK software UL, IEC, CSA, UL 61010A-1, EN/IEC 61010-1, CAN/CSA C22.2 No. 1010.1 Line voltage: 120 or 240 VAC Frequency: 50 or 60 Hz Power Consumption: 600 VA (analyzer); 200 VA (data station) 2 segments x 24 tests Up to 2 different tests on board simultaneously; each thermal cycler can run individual PCR profiles PCR-ready set-up samples 70 L 100 L Up to 10 different PCR profiles (methods) can be stored and protected from unintentional modifications 40C 98C 1C over the range of 40C 98C Up to 4 different wavelength combinations are supported (filterwheel) Filter Set 1 Set 2 Set 3 Set 4 Excitation Filter 485 nm 540 nm 485 nm 485 nm Emission Filter 520 nm 575 nm 645 nm 725 nm
Thermal Cycler Segments Loading Capacity Samples Sample Volumes Utility Channel Definitions Temperature Control Range Temperature Accuracy Number of Color Detections Filter Specifications
For more information, contact your Roche Diagnostics representative or call 1-800-428-5074.