SL1500 Wind Turbine Technical Data Sheet

TYPE Wind turbine class Rated powerkW Cut-in wind speedm/s Rated wind speedm/s Cut-out wind speedm/s Survival wind speedm/s Operation Operating temperature range SL1500/70 IEC //S 1500 3 12 25 59.5/52.5 Normal temperature type -15~+45 Survival temperature () Longevity of design (year) Averaged availability of wind farm (%) Rotor Rotor diameterm Swept aream Rated rotational rpm Number of blades Rotational direction (from up wind) speed/range
2

SL1500/77 IEC 1500 3 11 20 59.5/52.5 Low temperature type -30~+45 -45~+45 Normal temperature type -15~+45 -25~+45 20 95 77.4 4657 17.4/9.7~19 3 clockwise Low temperatur e type -30~+45 -45~+45

SL1500/82 IEC / 1500 3 10.5 20 59.5/52.5 Normal temperature type -15~+45 -25~+45 20 95 82.9 5398 17.4/9.7~19 3 clockwise Low temperature type -30~+45 -45~+45

-25~+45 20 95 70.4 3892.5 20.1/11.5~21.2 3 Clockwise

PROPRIETARY INFORMATION

For use pursuant to the terms of the applicable Sinovel Agreement

Cone angle ( Tilt angle ( Power Regulation Blade length (m) Blades Material Type Number of Phase Rated powerkW Rated output voltageV FrequencyHz Rated rotational rpm Power factor Protection level Insulation level Generator Step-up transformer data Transformer rating Number transformer Winding PROPRIETARY INFORMATION of speed/range

0 4.5 pitch 34 GRP (glass plastic) reinforced

0 4.5 Pitch 37.5 GRP (glass plastic) reinforced

0 4.5 pitch 40.25 GRP (glass plastic) reinforced

Generator

Double-fed induction

Double-fed induction

Double-fed induction

generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV

generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV

generator
3 1520 690 60 2096/1200~2400 Capacitive 0.95 inductive 0.9 Rated: 1 IP54 F 35kV/0.69kV

1 Dyn11

1 Dyn11

1 Dyn11

For use pursuant to the terms of the applicable Sinovel Agreement

Connection Impedance Drive stage Gearbox Drive ratio Rated power (kW) Brake system Control system Major brake system Minor brake system Type Capacity (KVA) input/output voltage (VAC) Converter Input/output current (A) Range of input/output frequency (Hz) Tower type Hub height m Type/design Yaw system Drive Range of yaw speed Pitch system Pitch bearing type Pitch drive (/min) 7% 3 1:104 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020 7% 3 1:120 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020 7% 3 1:120 1700 Air-braking mechanical braking PLC 500 690/0~700 200/500 601% / 020

tubular steel tower


65/70/80 Active Sliding bearing pre-friction with

tubular steel tower


65/70/80/100 Active Sliding bearing pre-friction with

tubular steel tower


70/80 Active Sliding bearing pre-friction with

Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points contact ball bearing Multistage planetary gear

Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points bearing contact ball

Multistage planetary gear driven by conversion asynchronous motor 18.3~23.2 4 points bearing contact ball

Multistage planetary gear

Multistage planetary gear

PROPRIETARY INFORMATION

For use pursuant to the terms of the applicable Sinovel Agreement

driven by conversion asynchronous motor Lightning protection Design standard Resistance of earthing Nacelle Weight Rotor Blades kg kg kg IEC61024 ambient 4 55614 16462 35500 and local

driven by conversion asynchronous motor IEC61024 ambient 4 55614 16462 35900 and local

driven by conversion asynchronous motor IEC61024 ambient 4 55614 16462 36300 and local

If annual mean wind speed is about 6 to 7 m/s in local wind farm, we suggest that SL1500/77 or SL1500/82 wind turbines may be installed here. Especially, the later one is a better choice.

PROPRIETARY INFORMATION

For use pursuant to the terms of the applicable Sinovel Agreement