Documente Academic
Documente Profesional
Documente Cultură
Product Description
Issue Date
02 2008-08-30
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.
Website: Email:
Copyright Huawei Technologies Co., Ltd. 2008. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but the statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Contents
Contents
About This Document.....................................................................................................................1 1 Overall Structure of the DBS3900...........................................................................................1-1
1.1 Physical Structure of the DBS3900.................................................................................................................1-4 1.2 Physical Ports of the DBS3900.......................................................................................................................1-7 1.2.1 Physical Ports of the BBU3900..............................................................................................................1-7 1.2.2 Physical Ports of the RRU3606..............................................................................................................1-9 1.2.3 Physical Ports of the ODU3601CE......................................................................................................1-10 1.3 Logical Structure of the DBS3900................................................................................................................1-11 1.3.1 Logical Structure of the BBU3900.......................................................................................................1-11 1.3.2 Logical Structure of the RRU3606.......................................................................................................1-14 1.3.3 Logical Structure of the ODU3601CE.................................................................................................1-14 1.4 Software Structure of the BTS......................................................................................................................1-15
Contents
ii
Issue 02 (2008-08-30)
Figures
Figures
Figure 1-1 Hardware structure of the DBS3900...................................................................................................1-1 Figure 1-2 Major functional modules of the DBS3900........................................................................................1-4 Figure 1-3 BBU3900............................................................................................................................................1-4 Figure 1-4 Configuration of the BBU3900..........................................................................................................1-4 Figure 1-5 RRU3606 without its shell.................................................................................................................1-6 Figure 1-6 RRU3606 with its shell.......................................................................................................................1-6 Figure 1-7 ODU3601CE......................................................................................................................................1-7 Figure 1-8 Logical structure of the BBU3900 configured with the UELP/UFLP.............................................1-12 Figure 1-9 Logical structure of the BBU3900 configured with the UTRP........................................................1-13 Figure 1-10 Logical structure of the RRU3606..................................................................................................1-14 Figure 1-11 Logical structure of the ODU3601CE............................................................................................1-15 Figure 1-12 Software structure of the BTS........................................................................................................1-16 Figure 2-1 Indoor centralized installation of the DBS3900.................................................................................2-3 Figure 2-2 Indoor distributed installation of the DBS3900 (1)............................................................................2-4 Figure 2-3 Indoor distributed installation of the DBS3900 (2)............................................................................2-5 Figure 2-4 Outdoor centralized installation of the DBS3900...............................................................................2-6 Figure 2-5 Outdoor distributed installation of the DBS3900 (1).........................................................................2-8 Figure 2-6 Outdoor distributed installation of the DBS3900 (2).........................................................................2-9 Figure 4-1 Star networking mode.........................................................................................................................4-2 Figure 4-2 Chain networking mode......................................................................................................................4-3 Figure 4-3 Tree networking mode........................................................................................................................4-3 Figure 5-1 Networking of the operation and maintenance system.......................................................................5-2 Figure 6-1 Dimensions of the BBU3900..............................................................................................................6-7
Issue 02 (2008-08-30)
iii
Tables
Tables
Table 1-1 Boards in the BBU3900.......................................................................................................................1-5 Table 1-2 Physical ports of the RRU3606............................................................................................................1-9 Table 1-3 Physical ports of the ODU3601CE....................................................................................................1-10 Table 2-1 Indoor centralized installation of the DBS3900...................................................................................2-3 Table 2-2 Auxiliary devices used in the indoor distributed installation of the DBS3900....................................2-5 Table 2-3 Auxiliary devices used in the outdoor centralized installation of the DBS3900.................................2-6 Table 2-4 Auxiliary devices used in the outdoor distributed installation of the DBS3900..................................2-9 Table 3-1 Power supply configuration in indoor installation...............................................................................3-4 Table 3-2 Power supply configuration in outdoor installation.............................................................................3-4 Table 6-1 Transmit specifications in band class 0 (800 MHz).............................................................................6-2 Table 6-2 Receive specifications in band class 0 (800 MHz)..............................................................................6-2 Table 6-3 Transmit specifications in band class 1 (1900 MHz)...........................................................................6-3 Table 6-4 Receive specifications in band class 1 (1900 MHz)............................................................................6-3 Table 6-5 Transmit specifications in band class 5 (450 MHz).............................................................................6-3 Table 6-6 Receive specifications in band class 5 (450 MHz)..............................................................................6-4 Table 6-7 Transmit specifications in band class 6 (2100 MHz)...........................................................................6-4 Table 6-8 Receive specifications in band class 6 (2100 MHz)............................................................................6-4 Table 6-9 Transmit specifications in band class 14 (1900 MHz).........................................................................6-5 Table 6-10 Receive specifications in band class 14 (1900 MHz)........................................................................6-5 Table 6-11 Transmit specifications in band class 15 (AWS)...............................................................................6-5 Table 6-12 Receive specifications in band class 15 (AWS).................................................................................6-6 Table 6-13 RRU3606 cascading specifications of the DBS3900.........................................................................6-6 Table 6-14 BER threshold specifications of the DBS3900 on the transmission links.........................................6-6 Table 6-15 Input power supply of the BBU3900.................................................................................................6-7 Table 6-16 Technical specifications of the RRU3606..........................................................................................6-8 Table 6-17 Technical specifications of the ODU3601CE....................................................................................6-9 Table 6-18 Reliability specifications of the DBS3900.........................................................................................6-9 Table 6-19 Lightning protection specifications of the DBS3900.......................................................................6-10 Table 6-20 Climatic requirements for the storage environment of the equipment.............................................6-12 Table 6-21 Requirements for the concentration of mechanically active substances in the storage environment of the equipment......................................................................................................................................................6-14 Table 6-22 Requirements for the concentration of chemically active substances in the storage environment of the equipment............................................................................................................................................................6-14 Table 6-23 Requirements for the mechanical stress in the storage environment of the BBU............................6-15 Issue 02 (2008-08-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd v
Tables
Airbridge DBS3900 CDMA Distribution Base Station Product Description Table 6-24 Requirements for the mechanical stress in the storage environment of the RRU............................6-15 Table 6-25 Climatic requirements for the transportation environment of the equipment..................................6-16 Table 6-26 Requirements for the concentration of mechanically active substances in the transportation environment of the equipment..................................................................................................................................................6-17 Table 6-27 Requirements for the concentration of chemically active substances in the transportation environment of the equipment..................................................................................................................................................6-17 Table 6-28 Requirements for the mechanical stress in the transportation environment of the BBU.................6-18 Table 6-29 Requirements for the mechanical stress in the transportation environment of the RRU.................6-18 Table 6-30 Climatic requirements for the running environment of the equipment............................................6-19 Table 6-31 Requirements for the concentration of mechanically active substances in the running environment of the BBU...............................................................................................................................................................6-20 Table 6-32 Requirements for the concentration of chemically active substances in the running environment of the BBU.....................................................................................................................................................................6-20 Table 6-33 Requirements for the concentration of chemically active substances in the running environment of the RRU.....................................................................................................................................................................6-20 Table 6-34 Requirements for the mechanical stress in the running environment of the BBU...........................6-21 Table 6-35 Requirements for the mechanical stress in the running environment of the RRU...........................6-21
vi
Issue 02 (2008-08-30)
Product Version
The following table lists the product version related to this document. Product Name DBS3900 CDMA Product Version V400R006
Intended Audience
This document is intended for:
l l
Change History
For details, see Change History of the DBS3900 Product Description.
Organization
1 Overall Structure of the DBS3900 This describes the overall structure of the DBS3900. The DBS3900 consists of the BBU3900, RRU3606, ODU3601CE, cables, antenna system, and auxiliary devices. 2 Solutions for the Auxiliary Devices of the DBS3900 This describes the solutions for the auxiliary devices of the DBS3900. The DBS3900 uses a modular structure. The basic modules of the DBS3900 are the BBU3900 and RRU3606, and the auxiliary devices of the DBS3900 include the indoor centralized installation rack, APM, storage battery cabinet, DCDU, EMUA, SLPU, ODF, DDF, DC power system, and AC power system. The basic modules and auxiliary devices can be flexibly configured to form proper site solutions.
Issue 02 (2008-08-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 1
3 Configuration Principles of the DBS3900 This describes the configuration principles of the DBS3900. 4 Transmission and Networking of the BTS This describes the transmission and networking of the BTS. The networking modes supported by the BTS are the start networking mode, chain networking mode, and tree networking mode. 5 Operation and Maintenance of the BTS This describes the operation and maintenance of the BTS. The operation and maintenance of the BTS refers to the management, monitoring, and maintenance of the BTS. The DBS3900 provides various methods and platforms for operation and maintenance to cater to different scenarios. 6 Technical Specifications of the DBS3900 This describes the technical specifications of the DBS3900.
Conventions
1. Symbol Conventions The following symbols may be found in this document. They are defined as follows Symbol Description Indicates a hazard with a high level of risk that, if not avoided, will result in death or serious injury. Indicates a hazard with a medium or low level of risk which, if not avoided, could result in minor or moderate injury. Indicates a potentially hazardous situation that, if not avoided, could cause equipment damage, data loss, and performance degradation, or unexpected results. Indicates a tip that may help you solve a problem or save your time. Provides additional information to emphasize or supplement important points of the main text.
DANGER
WARNING
CAUTION
TIP
NOTE
Description Normal paragraphs are in Times New Roman. Names of files,directories,folders,and users are in boldface. For example,log in as user root . Book titles are in italics.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd Issue 02 (2008-08-30)
Convention Courier New 3. Command Conventions Convention Boldface Italic [] {x | y | ...} [ x | y | ... ] { x | y | ... } * [ x | y | ... ] *
Description The keywords of a command line are in boldface. Command arguments are in italic. Items (keywords or arguments) in square brackets [ ] are optional. Alternative items are grouped in braces and separated by vertical bars.One is selected. Optional alternative items are grouped in square brackets and separated by vertical bars.One or none is selected. Alternative items are grouped in braces and separated by vertical bars.A minimum of one or a maximum of all can be selected. Alternative items are grouped in braces and separated by vertical bars.A minimum of zero or a maximum of all can be selected.
4. GUI Conventions Convention Boldface > Description Buttons,menus,parameters,tabs,window,and dialog titles are in boldface. For example,click OK. Multi-level menus are in boldface and separated by the ">" signs. For example,choose File > Create > Folder .
5. Keyboard Operation Convention Key Key1+Key2 Key1,Key2 Description Press the key.For example,press Enter and press Tab. Press the keys concurrently.For example,pressing Ctrl+Alt+A means the three keys should be pressed concurrently. Press the keys in turn.For example,pressing Alt,A means the two keys should be pressed in turn.
6. Mouse Operation
Issue 02 (2008-08-30)
Description Select and release the primary mouse button without moving the pointer. Press the primary mouse button twice continuously and quickly without moving the pointer. Press and hold the primary mouse button and move the pointer to a certain position.
Issue 02 (2008-08-30)
RRU3606
Issue 02 (2008-08-30)
Description As the remote RF module unit of the DBS3900, this component is responsible for transmitting and receiving radio signals to realize the communication between the wireless network and MSs.
NOTE
The RRU3606 and ODU3601CE differ in that the RRU3606 supports the 800 MHz, 1900 MHz, and 2100 MHz band classes and band class 15 (AWS) whereas the ODU3601CE supports the 450 MHz band class.
Supporting -48 V DC and 110/220 V AC power supply Providing at most 12 U [21.00 in.] space for user equipment when not configured with additional devices Supporting internal storage batteries in the case of AC input Supporting stack installation with the storage battery cabinet, which is optional
l l
DCDU EMUA
The DCDU is a DC power distribution box and supports one -48 V power input and multiple -48 V outputs. The EMUA is an environment monitoring unit and implements monitoring for the site environment and user equipment. For details about the functions of the EMUA, see the EMUA User Guide.
SLPU
The SLPU is a lightning protection unit. It holds the UELP and UFLP and implements lightning protection for E1/T1 and FE/ GE signals for the BBU3900. DDFs are classified into two types, which are used for coaxial cables and twisted-pair cables respectively. A DDF is required when the transmission equipment and BBU3900 are configured in the same cabinet. Made up of PSUDC/DC modules, the DC power system converts +24 V DC input to -48 V DC output. Made up of PSUAC/DC modules and PMU modules, the AC power system converts 220/110 V AC input to -48 V DC output.
DDF
This describes the physical structure of the DBS3900, which consists of the BBU3900, RRU3606, ODU3601CE, and auxiliary devices. 1.2 Physical Ports of the DBS3900 This describes the physical ports of the DBS3900. 1.3 Logical Structure of the DBS3900 This describes the logical structure of the DBS3900. 1.4 Software Structure of the BTS This describes the software structure of the BTS. The BTS software consists of the platform software, signaling protocol software, operation and maintenance software, and data center.
Issue 02 (2008-08-30)
1-3
NOTE
In the 450 MHz band class, the major functional modules of the DBS3900 are the BBU3900 and ODU3601CE.
Figure 1-4 shows the configuration of the BBU3900. Figure 1-4 Configuration of the BBU3900
1-4
Issue 02 (2008-08-30)
Table 1-1 Boards in the BBU3900 Board CMPT Full Name CDMA Main Processing&Transmission Unit Function
l
It processes and transmits data between the BTS and the BSC, controls and manages the entire BTS, and provides clock signals for the BTS system. It supports E1, T1, and FE links and supports IP transmission.
HCPM
HERT channel processing module HERT Enhance Channel Processing Module Universal Extension Transmission Processing Unit Universal E1/T1 Lighting Protection Unit Universal FE Lighting Protection Unit FAN Unit Universal Power and Environment Interface Unit
It processes the CDMA2000 1X service data on forward and reverse channels. It processes the CDMA2000 1xEV-DO service data on forward and reverse channels. It provides connection between the BBU3900 and the BSC, and supports E1/T1 and IP transmission. It provides lightning protection for E1/T1 signals. It provides lightning protection for FE signals. It provides heat dissipation for the BBU3900. It converts 48 V or +24 V DC power into +12 V DC power and provides environment monitoring signal ports. It provides the input port for external signals (including satellite clock signals) and provides synchronization clock signals for the BBU3900 and the RF modules connected to the BBU3900.
HECM
UTRP
USCU
Issue 02 (2008-08-30)
1-5
1-6
Issue 02 (2008-08-30)
Issue 02 (2008-08-30)
Board
Ports
Quantit y
Function Transmission port that connects to the BSC. Each port provides one FE link. l FE electric port, supporting electric cable l SFP interface, supporting SFP electric cable/optical cable (optical module required) Reserved Clock test port Commissioning port, which can be used for local maintenance Input port for GPS signals Compliable with the CPRI/GIGA protocol, connected to the RF unit Used for the DC power input Providing dry contact connections to two external alarm devices Providing dry contact connections to eight external alarm devices
1 1 1
1 3
SMA SFP
1 1 1 1 1
1-8
Issue 02 (2008-08-30)
Board
Ports OUTSIDE
Quantit y 1
Function Four E1/T1 signal interfaces, connected to the external equipment Connected to the CMPT Connected to external devices Connected to the RGPS signal cable Connected to the BITS clock Output port for test clock signals Input port for RF signals of the satellite card Supporting eight E1/T1 links
UFLP
FE0 and FE1 ports (INSIDE) FE0 and FE1 ports (OUTSIDE)
2 2
RJ45 RJ45
USCU
RGPS port BITS port Test clock port Satellite antenna port
3 1 1 1 2
UTRP
E1/T1 port
1 1 1 4
Issue 02 (2008-08-30)
1-9
Type RF port
Port ANT_TX/RXA
Description Main transmitting/ receiving port Diversity receiving port Used to share main received signals with other RRU3606s port Reserved
Quantity 1
Connector Type Round and waterproof DIN connector Round and waterproof DIN connector 2W2 connector
ANT_RXB
RX_IN/OUT
Reserved port
RET/ PWR_SRXU
NOTE
The specifications for the RRU3606 alarm port are: 0.2 kohm for the closed resistance; 51 kohms for the open resistance.
Connector Type DLC connector 3-pin aerial female connector 3-pin aerial female connector
RF port
1-10
Type
Quantity 1
Connector Type Round and waterproof DIN connector 3-pin aerial female connector
The MAPM provides the storage battery port. The silkscreen BATTERY. Silkscreen on the MAPM: ALARM INPUT Silkscreen on the MDPM: ALARM INPUT
Alarms port
Four dry contact outputs Four dry contact outputs and one dry contact ground
Issue 02 (2008-08-30)
1-11
Figure 1-8 Logical structure of the BBU3900 configured with the UELP/UFLP
HCPM: HERT channel processing module UPEU: universal power and environment interface unit UELP: universal E1/T1 lighting protection unit
HECM: HERT enhanced channel CMPT: main control and processing module transmission unit FAN: fan box UFLP: universal FE/GE lighting protection unit USCU: universal satellite card and clock unit
1-12
Issue 02 (2008-08-30)
Figure 1-9 Logical structure of the BBU3900 configured with the UTRP
l l
The UELP/UFLP or the UTRP cannot be simultaneously configured in the BBU3900. When the UTRP is configured, the SLPU, which is independent of the BBU3900, provides lightning protection for the external signal cables of the BBU3900.
Providing the Abis interface and implementing protocol processing over the Abis interface Providing the interface between the BBU3900 and the RF subsystem Implementing protocol processing for the physical layer of the Um interface and the MAC layer of the common channel Connecting the DBS3900 to the transmission system and BSC through the E1/T1/FE ports provided by the transmission boards Connecting the baseband service processing boards to the RF modules through the SFP ports provided by the channel boards
Modulating and demodulating baseband data for CDMA2000 1X and CDMA2000 1xEVDO services Performing encoding and decoding for CDMA channels Providing clock signals for system synchronization Implementing resource management, operation and maintenance, and environment monitoring
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 1-13
l l l
Issue 02 (2008-08-30)
On the forward link, implementing up-conversion and power amplification for modulated transmitted signals and filtering the transmitted signals to make them meet the requirements of the air interface protocol On the reverse link, filtering the signals received by the antenna to suppress out-band interference and then performing low noise amplification, channel division, downconversion, and channel-selective filtering.
1-14
Issue 02 (2008-08-30)
OMTR: outdoor multi-carrier transceiver module OMPA: Outdoor multi-carrier power amplifier MDFU: micro-BTS duplexer and filter unit MAPM/MDPM: micro-BTS AC-DC power supply module/ micro-BTS DC-DC power supply module
On the forward links, implementing power-adjustable up-conversion and power amplification for modulated transmitted signals and filtering the transmitted signals to make them meet the requirements of the air interface protocol On the reverse link, filtering the signals received by the antenna to suppress out-band interference and then performing low noise amplification, channel division, downconversion, and channel-selective filtering.
Issue 02 (2008-08-30)
1-15
Platform Software
The major functions of the platform software are as follows:
l l l
Data Center
The data center stores the configuration data of each module.
Radio network layer protocol processing Transport network layer protocol processing Managing the internal logical resources of the BTS, for example, cells and channels, and implementing mapping between physical resources and logical resources
Equipment management Data configuration Performance management Commissioning management Alarm management
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd Issue 02 (2008-08-30)
1-16
Software management Tracing management Security management Backup management Log management
Issue 02 (2008-08-30)
1-17
ODU3601CE can be installed on a wall or pole close to the RF antenna. In this way, the costs of network construction are reduced.
2-2
Issue 02 (2008-08-30)
Installation Scenarios
Figure 2-1 shows the indoor centralized installation of the DBS3900. Figure 2-1 Indoor centralized installation of the DBS3900
Auxiliary Devices
Table 2-1 lists the auxiliary devices used in the indoor centralized installation of the DBS3900. Table 2-1 Indoor centralized installation of the DBS3900 Device Indoor centralized installation rack Description Two types of indoor centralized installation racks are available and used for the BBU3900 and RRU3606 respectively. Indoor centralized installation racks can be installed on the ground, on a wall, or in a stack way.
2-3
Issue 02 (2008-08-30)
Device DCDU
Description The DCDU is a DC power distribution box and supports one -48 V power input and multiple -48 V outputs.
NOTE
The RRU3606 uses different duplexers for the A and AB sub-band classes of the 800 MHz band class. When working in the AB sub-band class of the 800 MHz band class, the RRU3606 does not support installation on the centralized installation rack. If the cabinet in the equipment room has enough free space, the BBU3900 can be installed in the cabinet, and the RRU3606 can be installed on a wall. In this case, the indoor centralized installation rack is not required, and therefore the space in the equipment room is saved. The auxiliary devices should be configured according to the actual situation in the equipment room.
Installation Scenarios
l
Figure 2-2 shows the indoor distributed installation of the BBU3900 and RRU3606. Figure 2-2 Indoor distributed installation of the DBS3900 (1)
Figure 2-3 shows the indoor distributed installation of the BBU3900 and ODU3601CE.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd Issue 02 (2008-08-30)
2-4
Auxiliary Devices
Table 2-2 lists the auxiliary devices used in the indoor distributed installation of the DBS3900. Table 2-2 Auxiliary devices used in the indoor distributed installation of the DBS3900 Device Indoor centralized installation rack Description Two types of indoor centralized installation racks are available and used for the BBU3900 and RRU3606 respectively. Indoor centralized installation racks can be installed on the ground, on a wall, or in a stack way. The DCDU is a DC power distribution box and supports one -48 V power input and multiple -48 V outputs.
DCDU
NOTE
l l
If the distance between the RRU3606 and the BBU3900 exceeds 50 m [164.04 ft], independent power supply equipment needs to be configured for the RRU3606. The auxiliary devices should be configured according to the actual situation in the equipment room.
Installation Scenarios
Figure 2-4 shows the outdoor centralized installation of the DBS3900. Figure 2-4 Outdoor centralized installation of the DBS3900
Auxiliary Devices
Table 2-3 lists the auxiliary devices used in the outdoor centralized installation of the DBS3900. Table 2-3 Auxiliary devices used in the outdoor centralized installation of the DBS3900 Device APM30 (220/110 V AC type) APM30 (-48 V DC type) Description The APM30 of the 220/110 V AC type is an integrated power system that is used for outdoor applications and supports 220/110 V AC power input. The APM30 of the -48 V DC type is an integrated power backup system that is used for outdoor applications and supports -48 V DC power input.
Issue 02 (2008-08-30)
2-6
Description The storage battery cabinet is optional and used for power backup. When the mains supply fails, the storage battery cabinet powers the equipment.
NOTE
l l
If the distance between the RRU3606 and the BBU3900 exceeds 50 m [164.04 ft], independent power supply equipment needs to be configured for the RRU3606. The auxiliary devices should be configured according to the actual situation and power input mode.
Installation Scenarios
l
Figure 2-5 shows the outdoor distributed installation of the BBU3900 and RRU3606.
Issue 02 (2008-08-30)
2-7
Figure 2-6 shows the outdoor distributed installation of the BBU3900 and ODU3601CE.
2-8
Issue 02 (2008-08-30)
Auxiliary Devices
Table 2-4 lists the auxiliary devices used in the outdoor distributed installation of the DBS3900. Table 2-4 Auxiliary devices used in the outdoor distributed installation of the DBS3900 Device APM30 (220/110 V AC type) Description The APM30 of the 220/110 V AC type is an integrated power backup system that is used for outdoor applications and supports 220/110 V AC power input. The APM30 of the -48 V DC type is an integrated power backup system that is used for outdoor applications and supports -48 V DC power input. The storage battery cabinet is optional and used for power backup. When the mains supply fails, the storage battery cabinet powers the equipment.
Issue 02 (2008-08-30)
2-9
l l
If the distance between the RRU3606 and the BBU3900 exceeds 50 m [164.04 ft], independent power supply equipment needs to be configured for the RRU3606. The auxiliary devices should be configured according to the actual situation and power input mode.
2-10
Issue 02 (2008-08-30)
Issue 02 (2008-08-30)
3-1
CMPT configuration
A maximum of two CMPTs working in 1+1 backup mode can be configured. Each CMPT provides four E1/T1 ports and two FE ports. You can configure the CMPTs based on capacity requirements and service types. A maximum of six HCMPs can be configured. An HCPM reserves three SFP ports and supports removable optical modules. An HCPM is configured with only one CSM6700 chip. The chip processes 285 forward channels and 256 reverse channels. A maximum of six HECMs can be configured. An HECM reserves three SFP ports and supports removable optical modules. An HECM is configured with only one CSM6800 chip, which supports 192 subscribers. A maximum of two UTRPs working in load sharing mode or 1+1 backup mode can be configured. Each UTRP provides eight E1/T1 ports.
HPCM configuration
HECM configuration
UTRP configuration
FAN configuration A maximum of one FAN can be configured. UPEU configuration A maximum of two UPEUs working in 1+1 backup mode can be configured. USCU configuration A maximum of two USCUs can be configured. The USCU supports GPS or GPS/ GLONASS satellite card and RGPS signals.
UELP configuration A maximum of two UELPs can be configured. A UELP provides lightning protection for four E1/T1 links.
UFLP configuration A maximum of two UELPs can be configured. A UELP provides lightning protection for FE signals and supports two Ethernet connections.
3-2
Issue 02 (2008-08-30)
l l
With hybrid configuration of HCPMs and HECMs, the BBU3900 supports CDMA2000 1X and 1xEVDO services. The BBU3900 supports hybrid configuration of UELPs and UFLPs.
l l l
The UELP/UFLP or the UTRP cannot be simultaneously configured in the BBU3900. When the BBU3900 is configured with the UTRP, the SLPU can be used to provide lightning protection. The SLPU is an external universal lightning protection unit. It can house the UELP/UFLP. It is used for the lightning protection of the E1/T1/FE cables. The SLPU supports mixed configuration of the UELP and the UFLP. A maximum of four lightning protection boards can be configured. If a new site requires more than four E1/T1 links, Huawei recommends that you use the E1/T1 resources on the UTRP directly. If an expanded site requires more than four E1/T1 links, Huawei recommends that you use the E1/ T1 resources provided by the extended transmission board, apart from the four E1/T1 links on the main control transmission board.
The BBU3900 can be configured with the CMPT and UTRP at the same time.
l l
Configuration Principle
l l
One RRU3606/ODU3601CE supports one sector. The RRU3606 supports the 800 MHz, 1900 MHz, and 2100 MHz band classes and band class 15 (AWS). The ODU3601CE supports the 450 MHz band class. Generally, three to six RRU3606s/ODU3601CEs are configured for each DBS3900.
l l
Issue 02 (2008-08-30)
3-3
Table 3-1 Power supply configuration in indoor installation Power Input Method -48 V DC Power Supply Configuration DCDU
For omni-directional cells, use omni-directional antennas. For directional cells, use directional bi-polarization antennas or directional uni-polarization antennas according to the actual situation. For a large coverage area, use antennas with a great amount of gain (for omni-directional cells or directional cells). For sector antenna configuration, use directional antennas or omni-directional antennas according to the sector design in the network planning solution. For omni-directional cells, use two omni-directional uni-polarization antennas that work in duplex mode.
Generally, one DBS3900 requires only one set of satellite synchronization antenna equipment. When the DBS3900 is configured with only the CMPT, the system can receive only GPS signals. When the DBS3900 is configured with the USCU, the system supports GPS satellite cards, GLONASS cards and mainstream cards. In such cases, the system supports the RGPS signal port. The USCU supports GPS/GLONASS satellite cards. When the USCU is configured, the CMPT does not support satellite cards.
l l
The following configuration examples apply when the band class is 800 MHz, the power supply is 220 V AC, and the equipment is installed outdoors in distributed mode. In the 450 MHz band class, the ODU3601CE functions as the RF module.
O(1) Configuration
In the O(1) configuration (one carrier, one omni-directional cell), the following components are configured:
l l l l l
One BBU3900 APM30 Storage battery cabinet (optional) Two omni-directional antennas One RRU3606
S(4/4/4) Configuration
In the S(4/4/4) configuration (three sectors, four carriers per sector), the following components are configured:
l l l l
One BBU3900 APM30 Storage battery cabinet (optional) For each sector, two directional uni-polarization antennas or one directional bi-polarization antenna Three RRU3606s
Issue 02 (2008-08-30)
3-5
The BBU3900 and RRU3606/ODU3601CE form a BTS. For convenience and clarification, the BBU3900 and RRU3606/ODU3601CE are collectively referred to as the BTS.
4.1 Star Networking Mode This describes the application scenarios, advantages, and disadvantages of the star networking mode. 4.2 Chain Networking Mode This topic describes the application scenarios, advantages, and disadvantages of the chain networking mode. 4.3 Tree Networking Mode This describes the application scenarios, advantages, and disadvantages of the tree networking mode.
Issue 02 (2008-08-30)
4-1
Application Scenarios
As the most commonly used networking mode, the star networking mode is especially applicable to densely populated areas. Figure 4-1 shows the star networking mode. Figure 4-1 Star networking mode
Advantages
l
The BTS is directly connected to the BSC, thus guaranteeing simplicity in networking and convenience in engineering, maintenance, and capacity expansion. Data transmission is implemented directly between the BTS and the BSC, and therefore signals do not have to go through many nodes. In this way, the reliability of the line is high.
Disadvantages
The star networking modes requires more transmission resources than other networking modes.
Application Scenarios
The chain networking mode is applicable to sparsely populated strip areas, for example, areas along superhighways and railways. Figure 4-2 shows the chain networking mode.
4-2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd Issue 02 (2008-08-30)
Advantages
The chain networking mode helps reduce the costs of transmission equipment, of engineering construction, and of transmission link rental.
Disadvantages
l l l
Signals go through a large number of nodes, and therefore the line reliability is low. Faults in upper-level BTSs may affect the normal operation of lower-level BTSs. The number of chain levels cannot exceed three.
Application Scenarios
The tree networking mode is applicable to areas where network structures, site distribution, and subscriber distribution are complicated, for example, areas where subscribers are widely distributed and hot spots gather. Figure 4-3 shows the tree networking mode. Figure 4-3 Tree networking mode
Issue 02 (2008-08-30)
4-3
Advantages
The transmission cable loss in tree networking mode is less than that in star networking mode.
Disadvantages
l
Signals travel through many nodes, which cause low transmission reliability and construction and maintenance difficulties. Faults in upper-level BTSs may affect the normal operation of lower-level BTSs. Capacity expansion is difficult because it may require extensive network reconstruction. The number of tree levels cannot exceed three.
l l l
4-4
Issue 02 (2008-08-30)
Issue 02 (2008-08-30)
5-1
Maintenance through the centralized network management system: The M2000, Huawei's centralized management system for wireless networks, can be used to maintain BTSs through the operation and maintenance network. The M2000 supports the operation and maintenance of sites, cells, carriers, channels, and boards. Centralized network management is used for the maintenance of multiple BTSs. Maintenance through the LMT: The LMT can be used to maintain the BTS through the operation and maintenance link provided by the Abis interface between the BSC and the BTS. The LMT communicates with the BSC through a LAN. Through the LMT, you can perform operation and maintenance for the sites, cells, carriers, channels, and boards. The LMT is used to configure and adjust the data of the BSC and BTS. Local maintenance: The maintenance terminal of the BTS is used to maintain the BTS locally through Ethernet. Through the maintenance terminal of the BTS, you can perform operation and maintenance for the sites, cells, carriers, baseband, channels, and boards. The maintenance terminal is used to maintain multiple BTSs.
5-2
Issue 02 (2008-08-30)
Equipment Management
Equipment management refers to equipment maintenance and data configuration. The detailed equipment management functions are as follows:
l
Equipment maintenance: board resetting, equipment status management, equipment selftesting, active/standby switchovers, and time calibration Data configuration: configuration, querying, and backup of equipment parameters, for example, configurations of the hardware, clock parameters, algorithm parameters, and RF parameters
Software Management
The detailed software management functions are as follows:
l l l l
Software activation Checking the consistency between software and hardware versions Querying hardware and software versions Upgrading the software version
Configuration Management
The detailed configuration management functions are as follows:
l l l
Checking data consistency in the addition, deletion, and modification of the BTS data Supporting automatic data backup Supporting dynamic data configuration, which enables the data to take effect immediately, and static data configuration, which requires the BTS to be reset for the data to take effect
Service Management
The detailed service management functions are as follows:
l
Supporting service operation and maintenance functions, such as parameter setting and alarm querying, for the equipment, such as baseband boards and environment monitoring device Supporting complete self-checks for hardware installation
Performance Management
The detailed performance management functions are as follows:
l
Monitoring the performance of the internal and external communication networks and generating alarms when the performance deteriorates.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 5-3
Issue 02 (2008-08-30)
Monitoring the running of the system, for example, monitoring of the traffic over each port and statistics of technical data during running Monitoring of the usage of key components such as the CPUs of boards
Security Management
The BTS supports the management of connection between the BTS software and the OMC, subscriber authentication and encryption, and forward and reverse resolution of interface messages.
Alarm Management
Alarm management refers to equipment alarm management and environment alarm management.
l
Equipment alarm management The equipment is monitored in real time. When a fault or exception occurs, an alarm is reported, and the alarm management function of the LMT or M2000 is used to display the alarm information and give suggestions for handling the alarm. The alarm management system of the M2000 is connected to an alarm box through the serial port and supports both audible and visual alarms. The user can subscribe to the alarms. When an alarm is generated, it is sent to the mobile phones or pagers of maintenance personnel so that the maintenance personnel can obtain the information of the fault or exception in time.
Environment alarm management Generally, the equipment room of the BTS are sparsely distributed and not attended. Compared with the equipment room of an exchange, the equipment room of the BTS has fewer and simpler facilities, and the equipment runs in harsh environments. Besides, accidents such as water damage and fire may occur in the equipment room. The BTS has a powerful environment monitoring subsystem, which guarantees the normal running of equipment and helps you deal with emergencies.
Alarm detection Alarm reporting Alarm masking Alarm confirmation Alarm pre-processing Alarm correlation processing Help information for alarm handling
Environment Monitoring
The detailed environment monitoring functions are as follows:
l
5-4
Issue 02 (2008-08-30)
Issue 02 (2008-08-30)
6-1
l l l l
The transmit power is the maximum value measured at the RF port of the cabinet. The multi-carrier transmit power refers to the total power instead of the power of each carrier. The signal receive sensitivity is the main and diversity receive sensitivity at RC3. Support for band class 5 is realized through the ODU3601CE, and support for the other band classes are realized through the RRU3606.
Receive and transmit specifications in band class 0 Table 6-1 and Table 6-2 list the performance specifications in band class 0 (800 MHz). Table 6-1 Transmit specifications in band class 0 (800 MHz) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 869 MHz to 894 MHz 1.2288 MHz 30 kHz 0.05 ppm 60 W
Table 6-2 Receive specifications in band class 0 (800 MHz) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 824 MHz to 849 MHz 1.2288 MHz 30 kHz Better than -128 dBm (main and diversity receiving at RC3)
6-2
Table 6-3 and Table 6-4 list the performance specifications in band class 1 (1900 MHz). Table 6-3 Transmit specifications in band class 1 (1900 MHz) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 1930 MHz to 1990 MHz 1.2288 MHz 50 kHz 0.05 ppm 60 W
Table 6-4 Receive specifications in band class 1 (1900 MHz) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 1850 MHz to 1910 MHz 1.2288 MHz 50 kHz Better than -127 dBm (main and diversity receiving at RC3)
Receive and transmit specifications in band class 5 Table 6-5 and Table 6-6 list the performance specifications in band class 5 (450 MHz). Table 6-5 Transmit specifications in band class 5 (450 MHz) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 460 MHz to 470 MHz 1.2288 MHz 25 kHz, 20 kHz 0.05 ppm 60 W
Issue 02 (2008-08-30)
6-3
Table 6-6 Receive specifications in band class 5 (450 MHz) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 450 MHz to 460 MHz 1.2288 MHz 25 kHz, 20 kHz Better than -127 dBm (main and diversity receiving at RC3)
Receive and transmit specifications in band class 6 Table 6-7 and Table 6-8 list the performance specifications in band class 6 (2100 MHz). Table 6-7 Transmit specifications in band class 6 (2100 MHz) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 2110 MHz to 2170 MHz 1.2288 MHz 50 kHz 0.05 ppm 60 W
Table 6-8 Receive specifications in band class 6 (2100 MHz) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 1920 MHz to 1980 MHz 1.2288 MHz 50 kHz Better than -127 dBm (main and diversity receiving at RC3)
Receive and transmit specifications in band class 14 Table 6-9 and Table 6-10 list the performance specifications in band class 14 (1900 MHz).
6-4
Issue 02 (2008-08-30)
Table 6-9 Transmit specifications in band class 14 (1900 MHz) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 1930 MHz to 1995 MHz 1.2288 MHz 50 kHz 0.05 ppm 60 W
Table 6-10 Receive specifications in band class 14 (1900 MHz) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 1850 MHz to 1915 MHz 1.2288 MHz 50 kHz Better than -127 dBm (main and diversity receiving at RC3)
Receive and transmit specifications in band class 15 (AWS) Table 6-11 and Table 6-12 list the performance specifications in band class 15 (AWS). Table 6-11 Transmit specifications in band class 15 (AWS) Item Working frequency band Channel bandwidth Channel precision Frequency tolerance Transmit power Specification 2110 MHz to 2155 MHz 1.2288 MHz 50 kHz 0.05 ppm 60 W
Issue 02 (2008-08-30)
6-5
Table 6-12 Receive specifications in band class 15 (AWS) Item Working frequency band Channel bandwidth Channel precision Signal receiving sensitivity Specification 1710 MHz to 1755 MHz 1.2288 MHz 50 kHz Better than -127 dBm (main and diversity receiving at RC3)
This describes the technical specifications of the BBU3900. 6.2.2 Technical Specifications of the RRU3606 This describes the technical specifications of the RRU3606. 6.2.3 Technical Specifications of the ODU3601CE The technical specifications of the ODU3601CE consist of the voltage, power consumption, weight, and dimensions.
Dimensions
The dimensions (height x width x depth) of the BBU3900 are 86 mm [3.39 in.] x 442 mm [17.40 in.] x 310 mm [12.20 in.], as shown in Figure 6-1. Figure 6-1 Dimensions of the BBU3900
Weight
l l
Empty cabinet (including the FAN and UPEU): 8 kg [17.64 lb] Fully-configured cabinet: 12 kg [26.46 lb]
NOTE
The UPEU is of two types, namely the UPEA and the UPEB. They support 48 V DC and +24 V DC power input respectively
Power Consumption
Power consumption of a fully-configured BBU3900: 250 W
Issue 02 (2008-08-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 6-7
Operation Environment
l
Ambient temperature -10 to +55 Relative humidity of the operating environment 5%RH to 95%RH
485 mm [19.21 in.] x 285 mm [11.02 in.] x 170 mm [6.10 in.] (with the shell) 480 mm [18.90 in.] x 270 mm [10.03 in.] x 140 mm [5.51 in.] (without the shell)
6-8
Issue 02 (2008-08-30)
110 V AC (dual-phase) voltage range: 90 V AC to 135 V AC 220 V AC (single-phase) voltage range: 176 V AC to 290 V AC
Power consumption Weight Cabinet dimensions (height x width x depth) Temperature Relative humidity
< 570 W 45 kg [99.23 lb] 620 mm [24.41 in.] x 400 mm [15.75 in.] x 405 mm [15.95 in.] -40 [-40] to +52 [+125.6] (solar radiation not considered) 5% to 100%
Issue 02 (2008-08-30)
6-9
Table 6-19 Lightning protection specifications of the DBS3900 Item AC power input port Specification Differential mode: 40 kA, 8/20 us Common mode: 40 kA, 8/20 us DC power input port Differential mode: 1 kA, 8/20 us Common mode: 2 kA, 8/20 us T1/E1 input port Differential mode: 3 kA, 8/20 us Common mode: 5 kA, 8/20 us GPS RF signal input port Differential mode: 8 kA, 8/20 us Common mode: 40 kA, 8/20 us Dry contact port Differential mode: 250 A, 8/20 us Common mode: 500 A, 8/20 us DC power input port of the RRU3606 Differential mode: 10 kA, 8/20 us Common mode: 15 kA, 8/20 us RF antenna port Differential mode: 8 kA, 8/20 us Common mode: 40 kA, 8/20 us
GB4943-2000: Safety of information technology equipment. IEC60950 Safety of information technology equipment Including Electrical Business Equipment. IEC60215 Safety requirement for radio transmitting equipment. CAN/CSA-C22.2 No 1-M94 Audio, Video and Similar Electronic Equipment. CAN/CSA-C22.2 No 950-95 Safety of Information Technology Equipment Including Electrical Business Equipment. UL 1419 Standard for Professional Video and Audio Equipment. 73/23/EEC Low Voltage Directive. UL 1950 Safety of information technology equipment Including Electrical Business Equipment. IEC60529 Classification of degrees of protection provided by enclosure. (IP Code). GOST 30631-99. General Requirements to machines, instruments and other industrial articles on stability to external mechanical impacts while operating. GOST R 50829-95. Safety of radio stations, radio electronic equipment using transceivers and their components. The general requirements and test methods.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd Issue 02 (2008-08-30)
l l l
l l l
l l
6-10
Council Directive 1999/5/EC: Commission communication in the framework of the implementation of Council Directive 1999/5/EC. Council directive 2004/108/EC: DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004. CISPR 22: "Limits and methods of measurement of radio disturbance characteristics of information technology equipment". IEC 61000-6-1: "Electromagnetic compatibility (EMC) Part 6: Generic standards Section 1: Immunity for residential, commercial and light-industrial environments". IEC 61000-6-3: "Electromagnetic compatibility (EMC) Part 6: Generic standards Section 3: mission standard for residential, commercial and light industrial environments". IEC 61000-3-2: "Electromagnetic compatibility (EMC) - Part 3: Limits Section 2: Limits for harmonic current emissions (equipment input current = 16 A) ". IEC 61000-3-3: "Electromagnetic compatibility (EMC) - Part 3: Limits Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current = 16 A". IEC 61000-4-2: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 2: Electrostatic discharge immunity test". IEC 61000-4-3: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 3: Radiated, radio-frequency electromagnetic field immunity test". IEC 61000-4-4: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 4: Electrical fast transient/burst immunity test". IEC 61000-4-5: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 5: Surge immunity test". IEC 61000-4-6: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 6: Immunity to contacted disturbances, induced by radio frequency fields". IEC 61000-4-11: " Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques Section 11: Voltage dips, short interruptions and voltage variations. Immunity tests". IEC61000-3-2: Electromagnetic compatibility: Part3: limits Section2: limits for harmonic current emissions(equipment input current less than or equal to 16A per phase). IEC61000-3-3: Electromagnetic compatibility: Part3: limits Section3: limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current less than or equal to 16A. ETSI 301 489-1: Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements. ETSI 301 489-26: ElectroMagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 26:
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 6-11
Issue 02 (2008-08-30)
Specific conditions for IMT-2000 CDMA Multi-carrier Base Stations and ancillary equipment.
l l l l
CFR 47, FCC Part 15-Radio Frequency Device. ITU-R Rec. SM.329-10: "Spurious emissions". IEC 61024-1: Protection of structures against lightning. IEC 61312-1: Protection Against Lightning Electromagnetic Impulse Part I: General Principles. ITU-T K.27(1996): Bonding Configurations and Earthing Inside a Telecommunication Building. ITU-T K.44 (2003): SERIES K: PROTECTION AGAINST INTERFERENCE Resistibility test for telecommunication equipment exposed to overvoltages and overcurrents - Basic recommendation. ETS 300 253(1995) Equipment Engineering; Earthing and bonding of telecommunication equipment in telecommunication centres. YD/T5098-2005: Design specifications about the overvoltage protection engineering of the telecommunications office.
ETSI EN 300 019-1-1 Class1.2 ETSI EN 300 019-1-2 Class2.3 ETSI EN 300 019-1-4 Class4.1
6.7.1 Storage environment This describes the requirements for the storage environment of the DBS3900. 6.7.2 Transportation Environment This describes the requirements for the transportation environment of the DBS3900. 6.7.3 Running Environment This describes the requirements for the running environment of the DBS3900.
Climatic Requirements
Table 6-20 lists the climatic requirements for the storage environment of the equipment. Table 6-20 Climatic requirements for the storage environment of the equipment Item Temperature
6-12
5000 m [16,404.2 ft] 70 kPa to 106 kPa 1120 W/m2 600 W/m2 BBU: 30 m/s RRU: 50 m/s
Waterproofing Requirements
The waterproofing requirements for the storage environment of the equipment are as follows:
l
No water accumulates on the ground or may drop onto the package of the equipment. The equipment is kept away from devices that may leak water, for example, automatic fire-fighting devices and heating devices. The package is intact. Appropriate waterproofing measures are taken to prevent rainwater from entering the package. No water accumulates on the ground or may drop onto the package of the equipment. The package is not exposed directly to sunlight.
Biological Requirements
The biological requirements for the storage environment of the equipment are as follows:
l l
The environment is not conducive to the growth of microorganisms, such as fungi. The equipment is protected from rodents, such as mice.
The air is free from explosive, electroconductive, magnetoconductive, and corrosive dust. The concentration of mechanically active substances complies with the requirements listed in Table 6-21.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 6-13
Issue 02 (2008-08-30)
Table 6-21 Requirements for the concentration of mechanically active substances in the storage environment of the equipment Mechanically Active Substance Suspended dust Precipitable dust Grit
NOTE
l The diameter of a suspended dust particle is not greater than 75 m. l The diameter of a precipitable dust particle is not smaller than 75 m and not greater than 150
Concentration Unit mg/m3 mg/m2h mg/m3 BBU 5 20 300 RRU 5 500 300
m.
l The diameter of a piece of grit is not smaller than 150 m and not greater than 1000 m.
The concentration of chemically active substances complies with the requirements listed in Table 6-22. Table 6-22 Requirements for the concentration of chemically active substances in the storage environment of the equipment Chemically Active Substance SO2 H2S NO2 Unit mg/m3 mg/m3 mg/m3 Concentration 0.30 0.10 BBU: 0.50 RRU: 0.05 NH3 Cl2 HCl HF O3 mg/m3 mg/m3 mg/m3 mg/m3 mg/m3 1.00 0.10 0.10 0.01 0.05
6-14
Issue 02 (2008-08-30)
Table 6-23 Requirements for the mechanical stress in the storage environment of the BBU Item Sinusoidal vibration Sub-item Offset Acceleration Frequency range Unsteady impact Impact response spectrum II Static payload
NOTE
l The impact response spectrum refers to the maximum acceleration response curve generated by the
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
Table 6-24 Requirements for the mechanical stress in the storage environment of the RRU Item Sinusoidal vibration Sub-item Offset Acceleration Frequency range Unsteady impact Impact response spectrum II Static payload
NOTE
l The impact response spectrum refers to the maximum acceleration response curve generated by the
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
Climatic Requirements
Table 6-25 lists the climatic requirements for the transportation environment of the equipment.
Issue 02 (2008-08-30)
6-15
Table 6-25 Climatic requirements for the transportation environment of the equipment Item Temperature Temperature change rate Relative humidity Altitude Air pressure Solar radiation Thermal radiation Wind speed Range -40oC [-40oF] to +70oC [+158oF] 3oC/min 5% RH to 95% RH 5000 m [16,404.2 ft] 70 kPa to 106 kPa 1120 W/m2 600 W/m2 BBU: 30 m/s RRU: 50 m/s
Waterproofing Requirements
The waterproofing requirements for the transportation environment of the equipment are as follows:
l l
The package is intact. Appropriate waterproofing measures are taken to prevent rainwater from entering the package. No water accumulates in the vehicle.
Biological Requirements
The biological requirements for the transportation environment of the equipment are as follows:
l l
The environment is not conducive to the growth of microorganisms, such as fungi. The equipment is protected from rodents, such as mice.
The air is free from explosive, electroconductive, magnetoconductive, and corrosive dust. The concentration of mechanically active substances complies with the requirements listed in Table 6-26.
6-16
Issue 02 (2008-08-30)
Table 6-26 Requirements for the concentration of mechanically active substances in the transportation environment of the equipment Mechanically Active Substance Suspended dust Precipitable dust Grit
NOTE
l The diameter of a suspended dust particle is not greater than 75 m. l The diameter of a precipitable dust particle is not smaller than 75 m and not greater than 150
Concentration Unit mg/m3 mg/m2h mg/m3 BBU No requirement 3.0 100 RRU 35 0.2 30
m.
l The diameter of a piece of grit is not smaller than 150 m and not greater than 1000 m.
The concentration of chemically active substances complies with the requirements listed in Table 6-27. Table 6-27 Requirements for the concentration of chemically active substances in the transportation environment of the equipment Chemically Active Substance SO2 H2S NO2 Unit mg/m3 mg/m3 mg/m3 Concentration 0.30 0.10 BBU: 0.50 RRU: 0.05 NH3 Cl2 HCl HF O3 mg/m3 mg/m3 mg/m3 mg/m3 mg/m3 1.00 0.10 0.10 0.01 0.05
Issue 02 (2008-08-30)
6-17
Table 6-28 Requirements for the mechanical stress in the transportation environment of the BBU Item Sinusoidal vibration Sub-item Offset Acceleration Frequency range Random vibration Acceleration spectral density Frequency range Unsteady impact Impact response spectrum II Static payload
NOTE
l The impact response spectrum refers to the maximum acceleration response curve generated by the
Range 7.5 mm [0.30 in.] 2 Hz to 9 Hz 10 m2/s3 2 Hz to 9 Hz 300 m/s2 10 kPa 20.0 m/s2 9 Hz to 200 Hz 3 m2/s3 9 Hz to 200 Hz 40. 0 m/s2 200 Hz to 500 Hz 1 m2/s3 200 Hz to 500 Hz
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
Table 6-29 Requirements for the mechanical stress in the transportation environment of the RRU Item Sinusoidal vibration Sub-item Offset Acceleration Frequency range Random vibration Acceleration spectral density Frequency range Unsteady impact Impact response spectrum II Static payload Range 3.5 mm [0.14 in.] 2 Hz to 9 Hz 30 m2/s3 2 Hz to 10 Hz 250 m/s2 10 kPa 10 m/s2 9 Hz to 200 Hz 3 m2/s3 10 Hz to 200 Hz 15 m/s2 200 Hz to 500 Hz 1 m2/s3 200 Hz to 500 Hz
6-18
Issue 02 (2008-08-30)
Item
NOTE
Sub-item
Range
l The impact response spectrum refers to the maximum acceleration response curve generated by the
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
Climatic Requirements
Table 6-30 lists the climatic requirements for the running environment of the equipment. Table 6-30 Climatic requirements for the running environment of the equipment Item Temperature Range BBU: -10oC [+14oC] to +55oC [+131oC] RRU: -40oC [-40oF] to +52C [+125.6oF] (solar radiation not considered) Temperature change rate Relative humidity 3oC/min BBU: 5%RH to 95%RH RRU: 5%RH to 100%RH Altitude Air pressure Solar radiation 4000 m [13,123.36 ft] 70 kPa to 106 kPa BBU: 700 W/m2 RRU: 1120 W/m2 Thermal radiation Wind speed 600 W/m2 BBU: 1 m/s RRU: 67 m/s
NOTE The temperature and humidity should be measured 1.5 m [4.92 ft] above the ground and 0.4 m [1.31 ft] away from the front of the cabinet when no protective board is installed at the front and rear of the cabinet.
Biological Requirements
The biological requirements for the running environment of the equipment are as follows:
Issue 02 (2008-08-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 6-19
The environment is not conducive to the growth of microorganisms, such as fungi. The equipment is protected from rodents, such as mice.
The air is free from explosive, electroconductive, magnetoconductive, and corrosive dust. The concentration of mechanically active substances complies with the requirements (for the BBU only) listed in Table 6-31. Table 6-31 Requirements for the concentration of mechanically active substances in the running environment of the BBU Mechanically Active Substance Dust particles Unit Particles/m3 Concentration 3 x 104 (no visible dust accumulated on desktops within three days) Note: The diameter of a dust particle is not smaller than 5 m.
The concentration of chemically active substances complies with the requirements listed in Table 6-32 and Table 6-33. Table 6-32 Requirements for the concentration of chemically active substances in the running environment of the BBU Chemically Active Substance SO2 H2S NH3 Cl2 Unit mg/m3 mg/m3 mg/m3 mg/m3 Concentration 0.20 0.006 0.05 0.01
Table 6-33 Requirements for the concentration of chemically active substances in the running environment of the RRU Chemically Active Substance SO2 H2S
6-20
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
Table 6-35 Requirements for the mechanical stress in the running environment of the RRU Item Sinusoidal vibration Sub-item Offset Acceleration Frequency range Range 3 mm [0.12 in.] 2 Hz to 9 Hz 10.0 m/s2 9 Hz to 200 Hz
Issue 02 (2008-08-30)
6-21
NOTE
l The impact response spectrum refers to the maximum acceleration response curve generated by the
equipment under specified impact excitation. Impact response spectrum II means that the duration of semi-sine impact response spectrum is 6 ms.
l The static payload refers to the capability of the packed equipment to bear the weight from above in
6-22
Issue 02 (2008-08-30)