Sunteți pe pagina 1din 354

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


5/4 ET 200S 5/226 ET 200M

5/65

Fail-safe modules

5/235 F Digital/Analog Modules

5/75

IQ-Sense Modules and Sensors

5/248 Digital Modules

5/77

Technology modules

5/269 Analog Modules

5/104 Motor Starter and Frequency Converter 5/120 Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe 5/145 Software

5/285 Analog Modules with HART 5/295 Ex Digital Modules

5/299 Ex Analog Modules

5/303 Function modules 5/148 ET 200iSP 5/331 IQ Sense Modules and Sensors 5/336 Special modules 5/201 RFID systems 5/338 Communication 5/208 Motor Starters and Frequency Converters 5/342 Power Supplies 5/220 Software 5/346 ET 200eco 5/221 ET 200L 5/353 ET 200R

5/173 ET 200pro

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


Overview of contents
Motor Starter and Frequency Converter Introduction ET 200S motor starters ET 200S FC frequency converter Power modules for ET 200S motor starters and frequency converters Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe Introduction ET 200S Failsafe motor starters ET 200S FC fail-safe frequency converter Safety modules local Safety Modules PROFIsafe Terminal modules for ET 200S motor starters and frequency converters Accessories for motor starters and frequency converters Software Motor Starter ES STARTER commissioning tool ET 200iSP Overview IM 152-1 interface module ET 200iSP digital electronic modules and terminal modules ET 200iSP analog electronic modules and terminal modules ET 200iSP watchdog module and terminal modules ET 200iSP reserve module and terminal modules ET 200iSP supply unit RS 485-IS Coupler ET 200pro Introduction IM 154-1 and IM 154-2 interface modules IM 154-4 PN interface modules IM 154-8 PN/DP CPU interface modules EM 141, EM 142 digital expansion modules EM 144, EM 145 analog expansion modules Failsafe digital expansion modules PM-E power module PM-O power module ET 200pro pneumatic interface RFID systems SIMATIC RF180C SIMATIC RF170C

5/4 5/4 5/6 5/12 5/13 5/15 5/16 5/21 5/22 5/23 5/27 5/28 5/29 5/32

5/33 5/34 5/35 5/45 5/47 5/64

5/65 5/66 5/67 5/70 5/71 5/73 5/75 5/76 5/77 5/78 5/80 5/82 5/84 5/86 5/89

5/90 5/93 5/95 5/98 5/100 5/102


Siemens IK PI 2009

ET 200S Introduction IM 151-1 interface module SIPLUS IM 151-1 interface module (extended temperature range) IM 151-3PN interface modules SIPLUS IM 151-3PN interface module (extended temperature range) IM 151-7 interface modules CPU IM 151-8 PN/DP CPU interface module Master interface module for IM 151-7(8) CPU/F-CPU IM 151-7 F CPU interface module SIPLUS IM 151-7 F-CPU interface module (extended temperature range) IM 151-8F PN/DP CPU interface module Power modules for PM-E electronic modules Power modules for PM-E SIPLUS electronics modules (extended temperature range) Reserve module Potential isolation module Digital electronic modules SIPLUS digital electronics modules (extended temperature range) Analog electronic modules SIPLUS analog electronic modules (extended temperature range) Fail-safe modules Overview PM-E F PROFIsafe F power module F electronic modules SIPLUS fail-safe electronics modules (extended temperature range) F electronic modules RELAY F terminal modules IQ-Sense Modules and Sensors 4 IQ-Sense and 8 IQ-Sense sensor modules IQ-Sense proximity switches Technology modules Overview SSI module 2 PULSE pulse generator 1 STEP step module 1 POS U positioning module 1 COUNT 24 V/100 kHz counter module SIPLUS 1 COUNT 24 V/100 kHz counter module (extended temperature range) 1 COUNT 5 V/500 kHz counter module 1SI interface module SIWAREX CS SIWAREX CF Terminal modules for power and electronic modules Terminal modules for power and electronic modules (extended temperature range)

5/104 5/105 5/110 5/118

5/120 5/121 5/123 5/131 5/136 5/139 5/142

5/145 5/146 5/148 5/148 5/151 5/154 5/160 5/165 5/167 5/169 5/171 5/173 5/173 5/175 5/178 5/181 5/186 5/190 5/196 5/197 5/199 5/200 5/201 5/205

Siemens AG 2008

5/208 5/210 5/211 5/215 5/217

5/220 5/221 5/226 5/227 5/231 5/233 5/235 5/238 5/239 5/242 5/243 5/246 5/247

Motor Starters and Frequency Converters ET 200pro Motor Starters ET 200pro motor starters ET 200pro isolator modules ET 200pro FC frequency converters ET 200pro Motor Starters Safety Modules Accessories for ET 200pro motor starters Software Motor Starter ES ET 200L ET 200M IM 153-1/153-2 SIPLUS IM 153-1/153-2 (extended temperature range) IM 153-4 PN F Digital/Analog Modules SM 326 F digital input module Safety Integrated SIPLUS SM 326 F digital input module Safety Integrated SM 326 F digital output module Safety Integrated SIPLUS SM 326 F digital output Safety Integrated SM 336 F analog input module Safety Integrated Isolation module SIPLUS isolating module (extended temperature range) Digital Modules SM321 digital input module SIPLUS SM 321 digital input module (extended temperature range) SM322 digital output module SIPLUS SM 322 digital output module (extended temperature range) SM 323/SM 327 digital input/output module SIPLUS SM 323 digital input/output module (extended temperature range) Analog Modules SM331 analog input module SIPLUS SM 331 analog input module (extended temperature range) SM 332 analog output module SIPLUS SM 332 analog output module (extended temperature range) SM 334 analog input/output module SIPLUS SM 334 analog input/output module (extended temperature range)

5/285 5/287 5/288 5/290 5/292 5/295 5/297 5/299 5/301 5/303 5/305 5/307 5/310 5/312 5/314 5/318 5/320 5/323 5/326 5/329 5/331 5/333 5/335

5/248 5/254 5/255 5/262 5/264 5/268

5/336 5/337 5/338 5/340 5/342 5/346 5/353

Analog Modules with HART Analog input module with HART SIPLUS SM 331 HART analog input module Analog output module with HART Ex-analog input module with HART Ex-analog output module with HART Ex Digital Modules Ex digital input modules Ex digital output modules Ex Analog Modules Ex analog input modules Ex analog output modules Function modules Introduction FM 350-1 counter module FM 350-2 counter module FM 351 positioning module FM 352 cam controller FM 352-5 high-speed Boolean processor FM 353 positioning module FM 354 positioning module FM 355 controller module FM355-2 temperature controller module SM 338 POS input module IQ Sense Modules and Sensors IQ-Sense sensor module SIMATIC PXO opto proximity switches with IQ-Sense SIMATIC PXS sonar proximity switches with IQ-Sense Special modules SM 374 simulator DM 370 dummy module Communication CP 340 CP 341 Power Supplies 2 A, 5 A, 10 A load power supplies ET 200eco ET 200R

5/269 5/276 5/277 5/280 5/281 5/284

Siemens IK PI 2009

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

Introduction

SIMATIC ET 200S Distributed I/O system to degree of protection IP20 with minimal wiring outlay, also for extremely time-critical tasks such as high-speed closed-loop controls Can be used with integrated S7-CPU as mini PLC: - also available as fail-safe PROFIsafe version - with optional lower-level PROFIBUS DP Bit-modular design for exact adaptation to the automation task in hand. Interface modules available with PROFIBUS DP or PROFINET interfaces Can be combined from digital and analog in/output modules, technology modules, motor starters and frequency converters for the control of drives up to 7.5 or 4 kW. Exchange of modules during operation (hot swapping), permanent wiring with multi-conductor connection Channel-specific diagnostics for high availability Can be supplied with integrated fiber optic interface if required Transmission rates up to 12 Mbit/s FastConnect using unstripped quick connection technology, screw or spring-loaded terminals Ex approval to Cat. 3 for Zone 2 acc. to ATEX100 a Slot reservation with spare modules Failsafe DI modules with safety-related signal processing according to PROFIsafe Option handling for simplest management of machine options

SIMATIC ET 200S COMPACT Block I/O to degree of protection IP20 with 32 channels, comprising terminal block and electronic block Discretely modular expansion to maximum of 128 channels or 12 modules The complete ET 200S module spectrum can be used (with the exception of PROFIsafe modules) Separation of terminal connections and electronics with permanent wiring Screw-type and spring-loaded terminal connections Standard terminal block with 2-wire connection system; 3-wire and 4-wire systems available using additional terminals Mounting on standard rail Hot swapping of expansion modules Communication via PROFIBUS Up to 100 byte inputs and outputs (address space)

5/4

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Introduction

General technical specifications


Degree of protection Ambient temperature Vibration resistance Maximum configuration (none of the limits listed below must be exceeded) Number of modules per IM 151, max. IM 151-1 BASIC: Up to 12 modules IM 151-1 COMPACT: Up to 12 modules IM 151-1 STANDARD: Up to 63 modules IM 151-1 HIGH-FEATURE: Up to 63 modules IM 151-7 CPU: Up to 63 modules IM 151-3 PN: Up to 63 modules IM 151-1 BASIC: Up to 2 m IM 151-1 COMPACT: Up to 2 m IM 151-1 STANDARD: Up to 2 m IM 151-1 HIGH-FEATURE: Up to 2 m IM 151-7 CPU: Up to 1 m IM 151-3 PN: Up to 2 m Depending on the number and type of connected modules IM 151-1 BASIC: Up to 88 byte for inputs and outputs IM 151-1 COMPACT: Up to 100 byte for inputs and outputs IM 151-1 STANDARD: Up to 244 byte for inputs and outputs IM 151-1 HIGH-FEATURE: Up to 244 byte for inputs and outputs IM 151-7 CPU: Not relevant IM 151-3 PN: 256 byte Depending on the number and type of connected modules IM 151-1 BASIC: 198 byte IM 151-1 COMPACT: 218 byte IM 151-1 STANDARD: Up to 244 byte IM 151-1 HIGH-FEATURE: Up to 244 byte IM 151-7 CPU: Not relevant IM 151-3 PN: Not relevant IP20 0 60 C 2 g continuously, 5 g temporarily (motor starter max. 2 g) Requirements of the DP master system PROFIBUS DP master Parameter length In accordance with EN 50170 >32 byte, depending on the number and type of connected modules Depending on the number and type of connected modules 17 64 byte (adjustable) EN 50170, Volume 2 IEC 1131, Part 2 acc. to UL508 standard, File No. E 116536/E 75310 (AC modules) AS/NZS 2064 (Class A) acc. to standard C22.2 No. 142, File No. LR 48323/LR 44226 (AC modules) acc. to UL 508 standard, File No. E 116536 acc. to hazardous locations UL 1604, File no. E 222109 acc. to CSA C22.2 standard, No. 142 Standard Class No. 3611, Class I, Division 2, Group A, B, C, D, Class I, Zone 2, Group IIC (without motor starter and frequency converter) American Bureau of Shipping Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyds Register of Shipping Nippon Kaiji Kyokai (without motor starters and frequency converters) EN 50021 (without frequency converters)

User data length Diagnostics length Standards and approvals PROFIBUS IEC 1131 UL C-Tick CSA

Line width, max.

cULus for hazardous locations

User data length

FM

Shipbuilding

Parameter length

Ex approval Cat. 3 (for Zone 2 acc. to ATEX100a)

Within the context of converting SIMATIC from UL / CSA to cULus, the ET 200S modules will also be converted

Dimensions
Dimensions in mm

Siemens IK PI 2009

5/5

G_IK10_EN_50071

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

IM 151-1 interface module

Interface module for linking the ET 200S to PROFIBUS DP Handles all data exchange with the PROFIBUS DP master 6 variants: - IM 151-1 BASIC (RS485) - IM 151-1 COMPACT 32DI DC24V (RS485) - IM 151-1 COMPACT 16DI DC24V / 16DO DC24V/0.5A (RS485) - IM 151-1 STANDARD (RS485) - IM 151-1 STANDARD (FO) - IM 151-1 HIGH FEATURE (RS485) Delivery including connecting module

The main differences between the IM 151-1 variants:

IM 151-1 BASIC Order No.: 6ES7 151Integral I/O Maximal number of I/O modules Maximum station width Maximal number of parameters Maximum address space for inputs and outputs Maximum diagnostics length Protocol DP connection type Firmware update Option handling Isochronous mode Maximum address volume per module Identification data Use of fail-safe modules (PROFIsafe) I-slave-to-slave communication 1CA00-0AB0 12 2m 198 byte 88 byte each

IM 151-1 COMPACT 1CA00-1BL00 1CA00-3BL00 32 DI 16DI / 16 DO 12 2m 218 byte 100 byte each

IM 151-1 STANDARD 1AA04-0AB0 63 2m 244 byte 244 byte

IM 151-1 FO STANDARD 1AB02-0AB0 63 1m 244 byte 128 byte

IM 151-1 HIGH FEATURE 1BA02-0AB0 63 2m 244 byte Depending on the DP master: 244 byte or not relevant 6 128 byte DP V0 and DP V1 RS485 Yes Yes Yes 32 byte Yes Yes Yes

6 43 byte DP V0 RS485 No No No 8 byte No No No

6 44 byte DP V0 RS485 No No No 8 byte No No No

6 122 byte DP V0 and DP V1 RS485 Yes Yes No 32 byte Yes No No

6 64 byte DP V0 Fiber-optic cable No Yes No 8 byte No No No

5/6

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

IM 151-1 interface module

Technical specifications
Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Voltages and currents Mains/voltage failure jumpering, min. Current consumption from supply voltage 1L+, max. Power loss, typ. Current output to backplane bus (DC 5 V), max. Address area Adressing volume Outputs Inputs interfaces PROFIBUS DP, Output current, max. 80 mA interface physics, RS 485 interface physics, LWL Protocols PROFIBUS DP protocol PROFIBUS DP Transmission speed, max. 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 1 200 m Yes Yes Yes No 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 12 Mbit/s 2m Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No 12 MBit/s 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s Yes Yes Yes Yes Yes; 9-pin Sub-D socket Yes; 4x Simplex socket Yes 80 mA Yes; 9-pin Sub-D socket 244 Byte 244 Byte 128 Byte 128 Byte 244 Byte 244 Byte 88 Byte 88 Byte 200 mA 3.3 W 200 mA 3.3 W 700 mA 200 mA 3.3 W 70 mA 1.5 W 20 ms 20 ms 20 ms 24 V Yes 24 V Yes 24 V Yes 24 V Yes 6ES7 151-1AA04-0AB0 6ES7 151-1AB02-0AB0 6ES7 151-1BA02-0AB0 6ES7 151-1CA00-0AB0

Cable length, max. SYNC capability FREECE capability direct data exchange (cross traffic) Isochronous mode Isochronouos mode Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Bus error BF (red) Collective error SF (red)

Yes Yes Yes Yes

No Yes Yes Yes Yes

Yes Yes Yes Yes Yes

No Yes Yes Yes Yes

Monitoring 24 V voltage supply ON Yes (green)

Siemens IK PI 2009

5/7

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

IM 151-1 interface module

Technical specifications (continued)


Order No. Isolation Isolation checked with Isolation between backplane bus and electronics between electronic block and PROFIBUS DP between supply voltage and electronics Permissible potential difference between different circuits General information Vendor identification (VendorID) Dimensions Dimensions Width 45 mm 119.5 mm 75 mm 150 g 6ES7 1511CA00-1BL0 45 mm 119.5 mm 75 mm 150 g 6ES7 1511CA00-3BL0 Order No. PROFIBUS DP Transmission procedure 24 V Yes 100 mA 24 V Yes 100 mA Cable length, max. direct data exchange (cross traffic) PROFINET IO Transmission speed, max. Isochronous mode Isochronouos mode 100 Byte 100 Byte 100 Byte 100 Byte 80 mA Yes No Yes No Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection Yes Yes No No Digital inputs Number of digital inputs Cable length Cable length unshielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. 3 ms 3 ms 3 ms 3 ms 4 mA; at 24 V min. 2 mA 3 mA 24 V -30 to +5 V 13 to 30 V 24 V -30 to +5 V 13 to 30 V 1 000 m 1 000 m 32 16 No No 12 MBit/s RS 485 1 200 m Yes RS 485 1 200 m Yes 45 mm 119.5 mm 75 mm 150 g 45 mm 119.5 mm 75 mm 150 g 6ES7 1511CA00-1BL0 6ES7 1511CA00-3BL0 806Ah 806Bh 80F3h 75 VDC / 60 VAC 500 V DC 75 VDC / 60 VAC 75 VDC / 60 VAC No Yes No No No No Yes No No Yes No 500 VDC 57 V DC / 60 V AC 500 VDC 500 VDC 6ES7 151-1AA04-0AB0 6ES7 151-1AB02-0AB0 6ES7 151-1BA02-0AB0 6ES7 151-1CA00-0AB0

Height Depth Weights Weight, approx. Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Current consumption from supply voltage 1L+, max. Address area Adressing volume Outputs Inputs interfaces PROFIBUS DP, Output current, max. interface physics, RS 485 interface physics, LWL Connection point Inputs/outputs

Protocols PROFIBUS DP protocol TCP/IP protocol PROFINET IO

5/8

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

IM 151-1 interface module

Technical specifications (continued)


Order No. Digital outputs Number of digital outputs Cable length unshielded, max. Short-circuit protection of the output Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output current for signal "1" permissible range for 0 to 60 C, min. for signal "0" residual current, max. Output delay with resistive load "0" to "1", max. "1" to "0", max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) up to 60 C, max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Run mode RUN (green) Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green) Monitoring 24 V voltage supply ON Yes (green) Connection to network LINK (green) Transmit/receive RX/TX (yellow) Yes Yes Yes Yes Yes Yes No No Yes Yes No No Yes 1.5 mA 2A 100 Hz 2 Hz 10 Hz 0.5 ms 1.3 ms 0.6 A 7 mA 16 1 000 m Yes L+ (-55 to -60 V) 5W Yes 6ES7 1511CA00-1BL0 6ES7 1511CA00-3BL0 Order No. Isolation Isolation checked with Isolation between backplane bus and electronics between supply voltage and electronics Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation, digital outputs Galvanic isolation, digital outputs Environmental requirements Degree and class of protection IP 20 General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx. 230 g 120 mm 81 mm 758 mm; 58 120 mm 81 mm 58 mm 8200H Yes Yes Yes No No No 500 VDC 500 VDC 6ES7 1511CA00-1BL0 6ES7 1511CA00-3BL0

Siemens IK PI 2009

5/9

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

IM 151-1 interface module

Ordering data
IM 151-1 BASIC interface module for ET 200S; transfer rates up to 12 Mbit/s; max. 12 power, electronic and motor start modules can be connected; bus connection via 9-pin Sub-D incl. termination module IM 151-1 COMPACT 32 DI 24 V DC interface module for ET 200S; transfer rates up to 12 Mbit/s; max. 32 digital inputs, can be expanded by max. 12 power, electronic and motor start modules; bus connection via 9-pin Sub-D incl. termination module IM 151-1 COMPACT 16 DI 24 V DC / 16 DO 24 V/0.5 A interface module for ET 200S; transfer rates up to 12 Mbit/s; max. 16 digital inputs and 16 digital outputs, can be expanded by max. 12 power, electronic and motor start modules; bus connection via 9-pin Sub-D incl. termination module IM 151-1 STANDARD interface module for ET 200S; transfer rates up to 12 Mbit/s; data volumes 244 byte each for inputs and outputs, max. 63 power, electronic and motor start modules can be connected; bus connection via 9-pin Sub-D incl. termination module IM 151-1 FO STANDARD interface module for ET 200S; transfer rates up to 12 Mbit/s; data volumes 128 byte each for inputs and outputs, max. 63 power, electronic and motor start modules can be connected; bus connection via integrated fiber-optic cable incl. termination module IM 151-1 HIGH FEATURE interface module for ET 200S; transfer rate up to 12 Mbit/s; data volumes 244 byte each for I/O, up to 63 modules can be connected; connection of PROFIsafe modules, isochronous mode; bus connection via 9-pin Sub-D incl. terminating module

Order No. 6ES7151-1CA00-0AB0 Accessories TM-C120S terminal module Terminal module for ET 200S COMPACT, screw-type terminals TM-C120C terminal module Terminal module for ET 200S COMPACT, spring-loaded terminals TE-U120S4x10 add-on terminal Add-on terminal for TM-C120x terminal modules of ET 200S COMPACT; screw-type terminals for 3-wire connection; please order two for 4-wire connection Can also be attached to TM-E/ TM-P, provided at least 120 mm of the construction width attains the same overall height as the terminal module TE-U120C4x10 add-on terminal Add-on terminal for TM-C120x terminal modules of ET 200S COMPACT; spring-loaded terminals for 3-wire connection; please order two for 4-wire connection Can also be attached to TM-E/ TM-P, provided at least 120 mm of the construction width attains the same overall height as the terminal module ET 200S distributed I/O system manuals are available on the Internet as PDF files: 6ES7151-1AB02-0AB0 SIMATIC Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) 6ES7151-1BA02-0AB0 SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates PROFIBUS DP bus connector RS 485 With 90 cable outlet for FastConnect connection system, max. transfer rate 12 Mbit/s Without PG interface With PG interface 100 Simplex connectors For plastic fiber-optic cable incl. 5 polishing sets 50 plug adapters For 2 Simplex connectors each

Order No.

6ES7 193-4DL10-0AA0

6ES7 193-4DL00-0AA0

6ES7151-1CA00-1BL0

6ES7 193-4FL10-0AA0

6ES7151-1CA00-3BL0

6ES7 193-4FL00-0AA0

6ES7151-1AA04-0AB0

http://www.siemens.com/ simatic-docu 6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

6ES7 972-0BA51-0XA0 6ES7 972-0BB51-0XA0 6GK1 901-0FB00-0AA0

6ES7 195-1BE00-0XA0

5/10

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

IM 151-1 interface module

Ordering data
Label sheets DIN A4 (10 units) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige Label sheets DIN A4 (10 units) Can be used for ET 200S COMPACT. Each sheet has 10 label strips beige yellow red petrol

Order No. Termination module as spare part for ET 200S SIMATIC S5, 35 mm DIN rail 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 Length: 483 mm for 19" cabinets Length: 530 mm for 600 mm cabinets Length: 830 mm for 900 mm cabinets Length: 2 m

Order No. 6ES7 193-4JA00-0AA0

6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41

6ES7 193-4BA10-0AA0 6ES7 193-4BB10-0AA0 6ES7 193-4BD10-0AA0 6ES7 193-4BH10-0AA0

More information
Terminal module selection aid
Power modules Screw-type terminal Order No. 6ES7 193... Spring-loaded terminal Order No. 6ES7 193... FastConnect Order No. 6ES7 193... PM-E DC 24 V PM-E 24 to 48 V DC PM-E 24 V DC/120/230V AC PM-E F 24 V DC PROFIsafe TM-P terminal modules for power modules 15S23-A1 4CC20-0AA0 15C23-A1 4CC30-0AA0 15N23-A1 4CC70-0AA0
n n n

5
15S23-A0 4CD20-0AA0 15C23-A0 4CD30-0AA0 15N23-A0 4CD70-0AA0
n n n

15S22-01 4CE00-0AA0 15C22-01 4CE10-0AA0 15N22-01 4CE60-0AA0


n n n

30S44-A0 4CK20-0AA0 30C44-A0 4CK30-0AA0 Available soon

Siemens IK PI 2009

5/11

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

SIPLUS IM 151-1 interface module (extended temperature range)

Ordering data
SIPLUS IM 151-1 STANDARD interface module (extended temperature range and medium load) For ET 200S; Transfer rates up to 12 Mbit/s; Data volumes 244 bytes each for inputs and outputs, max. 63 power-, electronic and motor start modules can be connected; bus connection via 9-pin Sub-D incl. termination module SIPLUS IM 151-1 HIGH FEATURE interface module (extended temperature range and medium load) For ET 200S; transfer rate up to 12 Mbit/s; data volumes 244 bytes each for inputs and outputs, up to 63 modules can be connected; connection of PROFIsafe modules, isochronous mode (clock synchronization); bus connection via 9-pin Sub-D incl. terminating module Accessories

Order No. 6AG1 151-1AA04-2AB0

6AG1 151-1BA02-2AB0

Interface module for linking the ET 200S to PROFIBUS DP Handles all data exchange with the PROFIBUS DP master

5
Order No. Order No. based on Ambient temperature range Environmental conditions

SIPLUS IM 151-1 Standard 6AG1 151-1AA04-2AB0 6ES7 151-1AA04-0AB0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

see IM 151-1 ordering data

Technical data

SIPLUS IM 151-1 High Feature Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 151-1BA02-2AB0 6ES7 151-1BA02-0AB0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

Note: For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

5/12

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

IM 151-3PN interface modules

Overview

Technical specifications
Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Voltages and currents Mains/voltage failure jumpering, min. Current consumption from supply voltage 1L+, max. Power loss, typ. Address area Adressing volume Outputs 256 Byte 256 Byte Yes Yes 100 Mbit/s Yes 256 Byte 256 Byte Yes Yes 100 Mbit/s Yes 250 mA 2.5 W 250 mA 2.5 W 20 ms 20 ms 24 V Yes 24 V Yes 6ES7 1513AA22-0AB0 6ES7 1513BA22-0AB0

Interface module for linking the ET 200S to PROFINET Handles all data exchange with the PROFINET I/O Controller 3 versions: - IM151-3 PN STANDARD - IM151-3 PN HIGH FEATURE and IM 151-3 PN FO: supports, in contrast to the STANDARD version, the operation of PROFIsafe F modules - with integrated 2-port switch for line topology Delivery including connecting module Note: Micro Memory Card required for operation of the IM 152-3 PN FO.

Inputs Connection point RJ45 Protocols PROFINET IO PROFINET IO Transmission speed, max. automatic detection of transmission speed Isochronous mode Isochronouos mode Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Bus error BF (red) Collective error SF (red)

No

No

Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes No Yes No

Monitoring 24 V voltage supply ON Yes (green) Connection to network LINK (green) Transmit/receive RX/TX (yellow) Isolation between backplane bus and electronics between Ethernet and electronics between supply voltage and electronics General information Vendor identification (VendorID) Device identifier (DeviceID) Dimensions Width Height Depth Weights Weight, approx. 120 g 60 mm 119.5 mm 75 mm 002AH 0301 No Yes No Yes Yes

002AH 0301H 60 mm 119.5 mm 75 mm 135 g

Siemens IK PI 2009

5/13

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

IM 151-3PN interface modules

Ordering data
IM 151-3 PN interface module for ET 200S; data transmission rates up to 100 Mbit/s; data volume depends on the number of modules inserted, up to 63 modules can be connected, bus connection through RJ45 IM 151-3 PN PROFINET High Feature interface module for ET 200S; data transmission rate up to 100 Mbit/s; max. 63 modules up to 2 m wide can be connected; bus connection via RJ45, incl. terminating module IM 151-3 FO interface module for ET 200S; with 2 PROFINET FO-interfaces and integrated 2-port switch, max. 63 modules up to 2 m wide can be connected, incl. terminating module Accessories Industrial Ethernet FC RJ45 Plug 90 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 90 cable outlet 1 unit 10 units 50 units Industrial Ethernet FastConnect installation cables Fast Connect standard cable Fast Connect trailing cable Fast Connect marine cable Termination Kits SC RJ POF Plug Assembly case for on-site assembly of SC RJ plugs consisting of stripping tool, kevlar cutter, microscope, abrasive paper, grinding support IE SC RJ POF Plug Screw-in plug for on-site assembly to POF fiber optic cable (1 pack = 20 units) IE SC RJ Refill Set POF Refill set for Termination Kit SC RJ POF Plug, consisting of abrasive paper and grinding plate (set of 5) SC RJ POF Plug Assembly case for on-site assembly of SC RJ plugs consisting of stripping tool, buffer stripping tool, kevlar cutter, fiber breaking tool, microscope Industrial Ethernet SC RJ PCF Plug Screw-in plug for on-site assembly to PCF fiber optic cable (1 pack = 10 units) Industrial Ethernet Fast Connect stripping tool MMC 64 KB 1) for storing the device name

Order No. 6ES7 151-3AA23-0AB0 MMC 128 KB 1) for storing the device name MMC 512 KB 1) for storing the device name MMC 2 MB 1) 6ES7 151-3BA23-0AB0 for storing the device name and/or firmware update MMC 4 MB 1) for storing the device name and/or firmware update MMC 8 MB 1) 6ES7 151-3BB22-0AB0 for storing the device name and/or firmware update ET 200S distributed I/O system manuals are available in the Internet as PDF files: SIMATIC Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) 6GK1 901-1BB20-2AA0 6GK1 901-1BB20-2AB0 6GK1 901-1BB20-2AE0 SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates Label sheets DIN A4 (10 units) 6XV1 840-2AH10 6XV1 840-3AH10 6XV1 840-4AH10 6GK1 900-0ML00-0AA0 Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige Terminating module as spare part for ET 200S 6GK1 900-0MB00-0AC0 DIN rail 35 mm Length: 483 mm for 19'' cabinets 6GK1 900-0MN00-0AA0 Length: 530 mm for 600 mm cabinets Length: 830 mm for 900 mm cabinets Length: 2 m 6GK1 900-0NL00-0AA0 Industrial Ethernet Switches Managed Industrial Ethernet Switches; Isochronous real time, LED diagnostics, fault signaling contact with SET button, redundant power supply 6GK1 900-0NB00-0AC0 SCALANCE X202-2P IRT; 2 x 10/100 Mbit/s RJ45 ports, 2 x 100 Mbit/s POF/PCF SC RJ SCALANCE X201-3P IRT; 1 x 10/100 Mbit/s RJ45 ports, 3 x 100 Mbit/s POF/PCF SC RJ SCALANCE X200-4P IRT; 4 x 100 Mbit/s POF/PCF SC RJ
1)

Order No. 6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0

6ES7 953-8LM20-0AA0

6ES7 953-8LP20-0AA0

http://www.siemens.com/ simatic-docu

6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 6ES7 193-4JA00-0AA0

6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41

6GK5 202-2BH00-2BA3

6GK5 201-3BH00-2BA3

6GK1 901-1GA00 6ES7 953-8LF20-0AA0

6GK5 200-4AH00-2BA3

For operating the IM 151-3, an MMC is essential

5/14

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

SIPLUS IM 151-3PN interface module (extended temperature range)

Overview

Ordering data
SIPLUS IM 151-3 PN interface module (extended temperature range and medial exposure) For ET 200S; transfer rates up to 100 Mbit/s; data volume depends on the number of modules inserted, up to 63 modules can be connected, bus connection through RJ45 Accessories

Order No.

6AG1 151-3AA22-2AB0

see IM 151-3PN ordering data

Interface module for interface to ET 200S PROFINET Handles all data exchange with the PROFINET I/O Controller IM151-3 PN STANDARD With integrated 2-port switch for line topology

Note: Micro Memory Card required for operation of CPU.


SIPLUS IM 151-3 PN Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 151-3AA22-2AB0 6ES7 151-3AA22-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Siemens IK PI 2009

5/15

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 interface modules CPU

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Product status associated programming package STEP7 V5.2 SP1 or higher + HW update 5 ms 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0

Voltages and currents Mains/voltage failure jumpering, min. Load voltage L+ Rated value (DC) Short-circuit protection reverse polarity protection permissible range, lower limit (DC) permissible range, upper limit (DC) 24 V Yes Yes 20.4 V 28.8 V

Interface module for SIMATIC ET 200S with integrated S7-CPU 314 For high-performance control solutions in ET 200S Increases the availability of plants and machinery Programming via PROFIBUS DP Compact SIMATIC Micro Memory Card (MMC) Integrated 12 Mbit/s PROFIBUS DP slave/MPI interface in copper design Integrated CPU based on CPU S7-314 IM 151-7 CPU FO available Fail-safe IM 151-7 F-CPU PROFIsafe available Also available as IM 151-8(F) PN/DP CPU with PROFINET interface Note: Micro Memory Card required for operation of CPU.

Current consumption Inrush current, max. from supply voltage 1L+, max. 3.5 A 250 mA; 280 mA with DP master module 3.3 W 700 mA

Power loss, typ. Current output to backplane bus (DC 5 V), max. Memory Type of storage RAM - integrated 48 KByte; as of FW V1.13 48 KB; previously 24 KB

96 KByte; For program and data No Yes 8 MByte 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

- expandable Load memory - pluggable (MMC) - pluggable (MMC), max. CPU/blocks Number of blocks (total)

DB Number, max. 127 511; Number range: 1 to 511 16 KByte 128 1 024; Number range: 0 to 2047 16 KByte 128 1 024; Number range: 0 to 2047 16 KByte 16 KByte

Size, max. FB Number, max.

Size, max. FC Number, max.

Size, max. OB Size, max.

5/16

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 interface modules CPU

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Nesting depth per priority class additional within an error OB CPU/processing times for bit operations, min. for word operations, min. for fixed point arithmetic, min. for floating point arithmetic, min. Times/counters and their remanence S7 counter Number Remanence - adjustable - lower limit - upper limit - preset Counting range - adjustable - lower limit - upper limit IEC counter Type Number SFB Unlimited (limited only by RAM capacity) 256 256 Yes 0 255 No retentivity 10 ms 9 990 s 10 ms 9 990 s SFB Unlimited (limited only by RAM capacity) 4 KByte 64 KByte Deviation per day, max. Operating hours counter 256 Byte 256 Byte Yes MB 0 to MB 15 8; 1 memory byte Granularity remanent Number Number/Number range Range of values 1 0 0 to 2^31 hours (when using SFC 101) 1 hour Yes; Must be restarted at each restart Time Clock Hardware clock (real-time clock) buffered and synchronizable Backup time Yes Yes 6 Weeks; At 40 C ambient temperature, typically 10 s Yes 1 999 Yes 0 999 Yes 0 255 From Z 0 to Z 7 Outputs Digital channels Inputs Outputs Inputs, of which central Outputs, of which central Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Adressing volume Outputs Inputs Hardware config. Number of modules per system, max. Connectable programming devices/PCs 63 PGs/OPs with STEP 7 connectable via PROFIBUS interface 63; Centralized 244 Byte 244 Byte 1 021 1 021 124 124 16 336 16 336 248 248 256 256 0.1 s 1 s 2 s 20 s 0.1 s 0.2 s 2 s 3 s 8 8 4 Size, max. Local data per priority class, max. Address area I/O address area Inputs Outputs Process image Inputs 128 Byte; Not adjustable 128 Byte; Not adjustable 2 048 Byte 2 048 Byte 510 Byte 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0 Order No. Data blocks Number, max. 511; Number range: 1 to 511 16 KByte 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0

S7 times Number Remanence - adjustable - lower limit - upper limit - preset Time range - lower limit - upper limit IEC timer Type Number

Data areas and their remanence Retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Remanence available Remanence preset Number of clock memories

Siemens IK PI 2009

5/17

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 interface modules CPU

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Clock synchronization supports to MPI, Master to MPI, Slave to DP, Master to DP, Slave in AS, Master in AS, Slave S7 message functions Number of login stations for message functions, max. Process diagnostic messages 12 Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ 40 Yes Yes Yes Yes Yes No No S7 communication supported as server as client Useful data per job, max. Useful data per job, of which consistent, max. S5-compatible communication supported Standard communication (FMS) supported Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 Yes Inputs, outputs 10 Yes Yes 2 Yes 100 Yes 100 No Yes Yes 4 4 4 22 Byte 22 Byte 1st interface Type of interface Physics isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master DP slave Point-to-point coupling Yes Yes No Yes No Integral RS 485 interface RS 485 Yes 80 mA Number of connections overall usable for PG communication reserved for PG communication usable for OP communication reserved for OP communication usable for S7 basic communication reserved for S7-Basic communication usable for routing 12 11 1 11 1 10 0 4; As slave only with active interface, with IM 151-7 CPU as DP master No No Yes Yes No 180 Byte 64 Byte 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0 Order No. S7 basic communication supported Useful data per job, max. Useful data per job (of which consistent) max. Yes 76 Byte 76 Byte; 76 bytes (XSEND/XRCV), 64 bytes (XPUT/XGET) as server 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0

simultaneously active Alarm-S blocks, max. Test commissioning functions Status/control Status/control variable Variables

Number of variables, max. of which status variable, max. of which control variable, max. Forcing Forcing Force, variables Number of variables, max. Status block Single step Number of breakpoints Diagnostic buffer present Number of entries, max. adjustable Communication functions PG/OP communication Global data communication supported Number of GD packets, max. Number of GD packets, transmitter, max. Number of GD packets, receiver, max. Size of GD packets, max. Size of GD packet (of which consistent), max.

5/18

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 interface modules CPU

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. MPI Number of connections 12; Notice: 12 connections per CPU, not per interface Yes Yes; With master module Yes Yes Yes No Yes 12 MBit/s 11 12; Notice: 12 connections per CPU, not per interface Yes; Only when interface active and in master mode Yes Yes No http://www. siemens.de/ profibus-gsd 12 MBit/s http://www. siemens.de/ profibus-gsd 12 MBit/s Yes; only with passive interface 244 Byte 244 Byte 32 32 Byte; Up to max. size of the transfer memory External interface via master module 6ES71384HA00-0AB0 RS 485 Yes No - S7 communication - S7 communication, as client - S7 communication, as server - equidistance support - SYNC/FREEZE - Activation/deactivation of DP slaves - direct data exchange (cross traffic) - DPV1 Transmission speeds, max. Number of DP slaves, max. Address area - Inputs, max. - Outputs, max. Useful data per DP slave - Inputs, max. - Outputs, max. Isochronous mode Isochronouos mode CPU/programming Programming language STEP 7 LAD FUP AWL SCL GRAPH Operational stocks Yes Yes Yes Yes Yes Yes; Optional Yes; Optional Binary logic See instruction operations, list bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions No 244 Byte 244 Byte 2 KByte 2 KByte 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0 Order No. DP master Number of connections, max. 12; Notice: 12 connections per CPU, not per interface Yes Yes No Yes; I blocks only Yes No Yes Yes Yes Yes Yes Yes 12 MBit/s 32; Per station 6ES7 1517AB00-0AB0 6ES7 1517AA20-0AB0

Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server Transmission speeds, max. DP slave Number of connections

Services - PG/OP communication - Routing - Global data communication - S7 basic communication

Services - Routing

- direct data exchange (cross traffic) - DPV1 GSD file

Transmission speeds, max. automatic baud rate search

Transfer memory - Inputs - Outputs Address area, max. Useful data per address area, max.

2nd interface Type of interface

Physics isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master Point-to-point coupling

No Yes No

Siemens IK PI 2009

5/19

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 interface modules CPU

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Nesting levels User program protection/password protection System functions (SFC) 6ES7 1517AB00-0AB0 8 Yes Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions 6ES7 1517AA20-0AB0 8 Yes See instruction list

Ordering data
IM 151-7 CPU FO interface module (48 K) Including termination module IM 151-7 CPU interface module (96 K) Including termination module Accessories MMC 64 KB 1) for program backup MMC 128 KB 1) for program backup MMC 512 KB 1) See instruction list 500 VDC Yes Yes for program backup MMC 2 MB 1) for program backup and/or firmware update MMC 4 MB 1) for program backup MMC 8 MB 1) for program backup External prommer 75 VDC / 60 VAC for e.g. MMC with USB interface PG with integrated MMC interface Label sheets DIN A4 (10 units)

Order No. 6ES7 151-7AB00-0AB0

6ES7 151-7AA20-0AB0

6ES7 953-8LF20-0AA0 6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0

System function blocks (SFB) Isolation Isolation checked with Isolation between load voltage and all other switching components between PROFIBUS DP all all other circuits Permissible potential difference between different circuits Environmental requirements Operating termperature min. max. Dimensions Width 60 mm 0 C 60 C

6ES7 953-8LM20-0AA0 6ES7 953-8LP20-0AA0 6ES7 792-0AA00-0XA0 upon request

Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules 60 mm; DP master module: 35 mm 119.5 mm 75 mm 200 g; DP master module: Approx. 100 g petrol red yellow light beige ET 200S distributed I/O system manuals are available in the Internet as PDF files: Terminating module as spare part for ET 200S SIMATIC S5, 35 mm DIN rail Length: 483 mm for 19'' cabinets Length: 530 mm for 600 mm cabinets Length: 830 mm for 900 mm cabinets Length: 2 m 6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41 6ES7 193-4JA00-0AA0 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 http://www.siemens.com/ simatic-docu

Height Depth Weights Weight, approx.

119.5 mm 75 mm 200 g

1)

For operating the CPU, an MMC is essential

5/20

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-8 PN/DP CPU interface module

SIMATIC ET 200 distributed I/Os

Overview
Interface module for SIMATIC ET 200S with integrated CPU S7-314 For high-performance control solutions in ET 200S Increase of the availability of systems and machines PROFINET IO-Controller for up to 128 IO-Devices PROFINET interface with integrated 3-port switch With many communication options: PG/OP communication, PROFINET IO, PROFINET CBA, open IE communication (TCP, ISO-on-TCP and UDP), web server and S7-communication (with loadable FBs) Fast, simple and end-to-end programming of a system with modular programs via STEP 7 Compact SIMATIC Micro Memory Card (MMC) Optional PROFIBUS master for 32 PROFIBUS DP slaves (with master interface 6ES7138-4HA00-0AB0) Fail-safe IM 151-8F PN/DP CPU PROFIsafe available Note: SIMATIC Micro Memory Card required for operation of CPU.

Ordering data
IM 151-8 PN/DP CPU interface module (128 K) IM 151-8F PN/DP CPU interface module (192 K) Including termination module Accessories MMC 64 KB 1) for program backup MMC 128 KB
1)

Order No. 6ES7 151-8AB00-0AB0 6ES7 151-8FB00-0AB0 Accessories (continued) ET 200S distributed I/O system manuals are available in the Internet as PDF files: Termination module 6ES7 953-8LF20-0AA0 6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0 as spare part for ET 200S SIMATIC S5, 35 mm DIN rail Length: 483 mm for 19" cabinets Length: 530 mm for 600 mm cabinets Length: 830 mm for 900 mm cabinets Length: 2 m Industrial Ethernet FC RJ45 Plug 180 6ES7 953-8LM20-0AA0 6ES7 953-8LP20-0AA0 6ES7 792-0AA00-0XA0 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 90 cable 1 unit On request 10 units 50 units Industrial Ethernet FastConnect Installation cables FastConnect Standard Cable FastConnect Trailing Cable 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 FastConnect Marine Cable Industrial Ethernet FastConnect Stripping Tool

Order No.

www.siemens.com/simatic-docu 6ES7 193-4JA00-0AA0

6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41

for program backup MMC 512 KB 1) for program backup MMC 2 MB 1) for program backup and/or firmware update MMC 4 MB 1) for program backup MMC 8 MB 1) for program backup External prommer for MMC, among others, with USB interface PG with integrated MMC interface Label sheets DIN A4 (10 units) Each sheet contains 60 labeling strips for peripheral modules and 20 labeling strips for interface modules petrol red yellow light beige
1)

6GK1 901-1BB10-2AA0 6GK1 901-1BB10-2AB0 6GK1 901-1BB10-2AE0

6XV1 840-2AH10 6XV1 840-3AH10 6XV1 840-4AH10 6GK1 901-1GA00

An MMC is essential to operate the CPU

Siemens IK PI 2009

5/21

Siemens AG 2008

ET 200S Interface module with integrated CPU


Master interface module for IM 151-7(8) CPU/F-CPU

SIMATIC ET 200 distributed I/Os

Overview

Ordering data
Master interface module for IM 151-7 CPU / IM 151-7 F-CPU interface modules Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige ET 200S distributed I/O system manuals are available in the Internet as PDF files:

Order No. 6ES7 138-4HA00-0AB0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 http://www.siemens.com/ simatic-docu

PROFIBUS DP master interface module for IM 151-7(F) CPU/IM 151-8(F) PN/DP CPU interface modules Integrated 12 Mbit/s PROFIBUS DP master interface in copper design Facilitates parallel operation of two PROFIBUS DP interfaces on one IM 151-7 CPU Enables operation of a PROFIBUS DP interface on an IM 151-8(F) PN/DP CPU Increases the availability of plants and machinery Functionality corresponds to the interface of an S7-314 CPU configured as DP master Programming is with STEP 7 from Version V5.2 with Service Pack 1.

Technical specifications
Order No. Hardware config. Number of modules per CPU Dimensions Dimensions Width Height Depth Weights Weight, approx. 100 g 35 mm 119.5 mm 75 mm 1 6ES7 138-4HA00-0AB0

5/22

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 F CPU interface module

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Product status associated programming package Voltages and currents Mains/voltage failure jumpering, min. Load voltage L+ Rated value (DC) Short-circuit protection reverse polarity protection permissible range, upper limit (DC) Current consumption from supply voltage 1L+, max. Power loss, typ. Current output to backplane bus (DC 5 V), max. Memory Type of storage RAM - integrated - expandable Load memory - pluggable (MMC) - pluggable (MMC), max. CPU/blocks Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. 511; Number range: 1 to 511 16 KByte 1 024; Number range: 0 to 2047 16 KByte 1 024; Number range: 0 to 2047 16 KByte 16 KByte 8 4 0.1 s 0.2 s 2 s 3 s Yes 8 MByte 128 KByte; For program and data No 24 V Yes Yes 28.8 V 5 ms STEP7 V5.2 SP1 or higher + HW update 6ES7 151-7FA20-0AB0

permissible range, lower limit (DC) 20.4 V

Interface module with integrated fail-safe CPU for SIMATIC ET 200S With DP/MPI interface For design of a fail-safe automation system for plants with increased safety requirements Complies with safety requirements up to SIL 3 according to IEC 61508, IEC 62061 and Cat. 4 according to EN 954-1 Fail-safe I/O modules can be connected in a distributed configuration through DP master modules (PROFIsafe) The fail-safe I/O modules of ET200S PROFIsafe can be connected in a centralized configuration Standard modules can be used for non-safety-relevant applications Note: Micro Memory Card required for operation of CPU.

250 mA; 280 mA with DP master module 3.3 W 700 mA

DB Number, max. Size, max. FB Number, max. Size, max. FC Number, max. Size, max. OB Size, max. Nesting depth per priority class additional within an error OB CPU/processing times for bit operations, min. for word operations, min. for fixed point arithmetic, min. for floating point arithmetic, min.

Siemens IK PI 2009

5/23

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 F CPU interface module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Times/counters and their remanence S7 counter Number Remanence - adjustable - lower limit - upper limit - preset Counting range - adjustable - lower limit - upper limit IEC counter Type Number SFB Unlimited (limited only by RAM capacity) 256 Yes 0 255 No retentivity 10 ms 9 990 s SFB Unlimited (limited only by RAM capacity) 64 KByte Granularity remanent Clock synchronization supports to MPI, Master to MPI, Slave in AS, Master in AS, Slave 256 Byte Yes MB 0 to MB 15 8; 1 memory byte 511; Number range: 1 to 511 16 KByte 510 Byte S7 message functions Number of login stations for message functions, max. Process diagnostic messages 12 Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ 40 Yes Yes Yes No No Yes 0 999 Yes 0 255 From Z 0 to Z 7 256 6ES7 151-7FA20-0AB0 Order No. Digital channels Inputs Outputs Inputs, of which central Outputs, of which central Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Hardware config. Number of modules per system, max. Time Clock Hardware clock (real-time clock) buffered and synchronizable Backup time Deviation per day, max. Operating hours counter Number Number/Number range Range of values 1 0 0 to 2^31 hours (when using SFC 101) 1 hour Yes; Must be restarted at each restart Yes Yes 6 Weeks; At 40 C ambient temperature, typically 10 s 63; Centralized 1 021 1 021 124 124 16 336 16 336 248 248 6ES7 151-7FA20-0AB0

S7 times Number Remanence - adjustable - lower limit - upper limit - preset Time range - lower limit - upper limit IEC timer Type Number Data areas and their remanence Retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Remanence available Remanence preset Number of clock memories Data blocks Number, max. Size, max. Local data per priority class, max. Address area I/O address area Inputs Outputs Process image Inputs Outputs 128 Byte; Not adjustable 128 Byte; Not adjustable 2 048 Byte 2 048 Byte

simultaneously active Alarm-S blocks, max. Test commissioning functions Status/control Status/control variable Variables Number of variables, max. of which status variable, max. of which control variable, max. Forcing Forcing Force, variables Number of variables, max.

Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 Yes Inputs, outputs 10

5/24

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 F CPU interface module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Status block Single step Number of breakpoints Diagnostic buffer present Number of entries, max. adjustable Communication functions PG/OP communication Global data communication supported Number of GD packets, max. Number of GD packets, transmitter, max. Number of GD packets, receiver, max. Size of GD packets, max. Size of GD packet (of which consistent), max. S7 basic communication supported Useful data per job, max. Useful data per job (of which consistent) max. S7 communication supported as server as client Useful data per job, max. Useful data per job, of which consistent, max. S5-compatible communication supported Standard communication (FMS) supported Number of connections overall usable for PG communication reserved for PG communication usable for OP communication reserved for OP communication usable for S7 basic communication reserved for S7-Basic communication usable for routing 12 11 1 11 1 10 0 4; As slave only with active interface, with IM 151-7 CPU as DP master No No Transmission speeds, max. automatic baud rate search Transfer memory - Inputs - Outputs Address area, max. Useful data per address area, max. 2nd interface Type of interface Physics isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master Point-to-point coupling No Yes No External interface via master module 6ES7138-4HA00-0AB0 RS 485 Yes No 244 Byte 244 Byte 32 32 Byte; Up to max. size of the transfer memory Yes Yes No 180 Byte 64 Byte Services - Routing - direct data exchange (cross traffic) - DPV1 GSD file Yes; Only when interface active and in master mode Yes No http://www.siemens.de/ profibus-gsd 12 MBit/s Yes; only with passive interface Yes 76 Byte 76 Byte; 76 bytes (XSEND/XRCV), 64 bytes (XPUT/XGET) as server Yes 4 4 4 22 Byte 22 Byte Yes Yes 100 No 6ES7 151-7FA20-0AB0 Yes Yes 2 Order No. 1st interface Type of interface Physics isolated Power supply to interface (15 to 30 V DC), max. Functionality MPI DP master DP slave Point-to-point coupling MPI Number of connections Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server Transmission speeds, max. DP slave Number of connections 12; Notice: 12 connections per CPU, not per interface Yes Yes; With master module Yes Yes Yes No Yes 12 MBit/s 12; Notice: 12 connections per CPU, not per interface Yes No Yes No Integral RS 485 interface RS 485 Yes 80 mA 6ES7 151-7FA20-0AB0

Siemens IK PI 2009

5/25

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-7 F CPU interface module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. DP master Number of connections, max. Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - equidistance support - SYNC/FREEZE - Activation/deactivation of DP slaves - direct data exchange (cross traffic) Yes Yes No Yes; I blocks only Yes No Yes Yes Yes Yes Yes Yes 12 MBit/s 32; Per station 2 KByte 2 KByte 244 Byte 244 Byte No 12; Notice: 12 connections per CPU, not per interface 6ES7 151-7FA20-0AB0 Order No. CPU/programming Programming language STEP 7 LAD FUP AWL SCL GRAPH Operational stocks Nesting levels User program protection/ password protection System functions (SFC) System function blocks (SFB) Isolation Isolation checked with Isolation between load voltage and all other switching components between PROFIBUS DP all all other circuits Permissible potential difference between different circuits Dimensions Width Height Depth Weights Weight, approx. 200 g; DP master module: Approx. 100 g 60 mm; DP master module: 35 mm 119.5 mm 75 mm 75 VDC / 60 VAC Yes Yes 500 VDC Yes Yes Yes Yes Yes; Optional Yes; Optional See instruction list 8 Yes See instruction list See instruction list 6ES7 151-7FA20-0AB0

- DPV1 Transmission speeds, max. Number of DP slaves, max. Address area - Inputs, max. - Outputs, max. Useful data per DP slave - Inputs, max. - Outputs, max. Isochronous mode Isochronouos mode

Ordering data
IM 151-7 F-CPU interface module for configuring a fail-safe automation system Accessories Distributed Safety V5.4 programming tool Task: Software for configuring fail-safe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade from V5.x to V5.3; Floating license for 1 user MMC 64 kbyte for program backup MMC 128 kbyte for program backup

Order No. 6ES7 151-7FA20-0AB0 MMC 512 kbyte for program backup MMC 2 Mbyte for program backup and/or firmware update MMC 4 Mbyte for program backup External prommer for MMC with USB interface Terminating module 6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5 as spare part for ET 200S SIMATIC S5, 35 mm DIN rail Length: 483 mm for 19'' cabinets Length: 530 mm for 600 mm cabinets 6ES7 953-8LF20-0AA0 6ES7 953-8LG11-0AA0 Length: 830 mm for 900 mm cabinets Length: 2 m

Order No. 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0

6ES7 953-8LM20-0AA0 6ES7 792-0AA00-0XA0 6ES7 193-4JA00-0AA0

6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41

5/26

Siemens IK PI 2009

Siemens AG 2008

ET 200S Interface module with integrated CPU


SIPLUS IM 151-7 F-CPU interface module (extended temperature range)

SIMATIC ET 200 distributed I/Os

Overview

Ordering data
SIPLUS IM 151-7 F-CPU interface module For configuring a fail-safe automation system (extended temperature range and medium load) Accessories

Order No. 6AG1 151-7FA20-2AB0

see IM 151-7 F-CPU ordering data

More information
For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Interface module with integrated fail-safe CPU for SIMATIC ET 200S With DP/MPI interface For constructing a fail-safe automation system for plants with increased safety requirements Complies with safety requirements up to SIL 3 according to IEC 61508, IEC 62061 and Cat. 4 according to EN 954-1 Fail-safe I/O modules can be connected in a distributed configuration through DP master modules (PROFIsafe) The fail-safe I/O modules of ET 200S PROFIsafe can be connected in a centralized configuration Note: Micro Memory Card required for operation of CPU.
SIPLUS IM 151-7 F-CPU Standard interface module Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 151-7FA20-2AB0 6ES7 151-7FA20-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Siemens IK PI 2009

5/27

Siemens AG 2008

ET 200S Interface module with integrated CPU


IM 151-8F PN/DP CPU interface module

SIMATIC ET 200 distributed I/Os

Overview
Interface module for SIMATIC ET 200S with integrated fail-safe CPU For constructing a fail-safe automation system for plants with increased safety requirements Complies with safety requirements up to SIL 3 according to IEC 61508, IEC 62061, up to PLe according to ISO 13849-1:2006 and Cat. 4 according to EN 954-1 For high-performance control solutions in ET 200S Increase of the availability of systems and machines PROFINET IO-Controller for up to 128 IO-Devices PROFINET interface with integrated 3-port switch With many communication options: PG/OP communication, PROFINET IO, PROFINET CBA, open IE communication (TCP, ISO-on-TCP and UDP), web server and S7-communication (with loadable FBs) Fast, simple and end-to-end programming of a system with modular programs via STEP 7 Compact SIMATIC Micro Memory Card (MMC) Optional PROFIBUS master for 32 PROFIBUS DP slaves (with master interface 6ES7138-4HA00-0AB0)
Order No. Label sheets DIN A4 (10 units) Each sheet contains 60 labeling strips for peripheral modules and 20 labeling strips for interface modules petrol red yellow light beige ET 200S distributed I/O system manuals are available in the Internet as PDF files: Termination module as spare part for ET 200S SIMATIC S5, 35 mm DIN rail Length: 483 mm for 19" cabinets 6ES7 953-8LF20-0AA0 6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0 Length: 530 mm for 600 mm cabinets Length: 830 mm for 900 mm cabinets Length: 2 m Industrial Ethernet FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 90 cable 1 unit 6ES7 953-8LP20-0AA0 6ES7 792-0AA00-0XA0 10 units 50 units Industrial Ethernet FastConnect Installation cables FastConnect Standard Cable On request FastConnect Trailing Cable FastConnect Marine Cable Industrial Ethernet FastConnect Stripping Tool
1)

Note: SIMATIC Micro Memory Card required for operation of CPU.

Ordering data
IM 151-8F PN/DP CPU interface module (192 K) Including termination module Distributed Safety V5.4 programming tool Task: Software for configuring fail-safe application programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating License Software Update Service Distributed Safety Upgrade From V5.3 to V5.4; Floating license for 1 user Accessories MMC 64 KB 1) for program backup MMC KB1) for program backup MMC 512 KB 1) for program backup MMC 2 MB 1) for program backup and/or firmware update MMC 4 MB 1) for program backup MMC 8 MB 1) for program backup External prommer for MMC, among others, with USB interface PG with integrated MMC interface

Order No. 6ES7 151-8FB00-0AB0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

www.siemens.com/simatic-docu 6ES7 193-4JA00-0AA0

6ES5 710-8MA11 6ES5 710-8MA21 6ES5 710-8MA31 6ES5 710-8MA41

6ES7 953-8LM20-0AA0

6GK1 901-1BB10-2AA0 6GK1 901-1BB10-2AB0 6GK1 901-1BB10-2AE0

6XV1 840-2AH10 6XV1 840-3AH10 6XV1 840-4AH10 6GK1 901-1GA00

An MMC is essential to operate the CPU

5/28

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Power modules for PM-E electronic modules

Overview
For monitoring and, depending on the version, fusing the load and sensor supply voltage Can be plugged onto TM-P terminal modules with automatic coding. Diagnostics message for voltage and blown fuse (can be switched off via configuration) Fail-safe PM-E F PROFIsafe power module for safe switching off of sequentially plugged-in 24 V DC to 10 A digital output modules or external loads; 3 additional integrated fail-safe 24 V DC / 2 A outputs 24 to 48 V DC PM-E power module - With status information and diagnosis "Load voltage present - For option handling PM-E 24 V DC to 230 V AC power module - Power module for universal use - For option handling

Design
PM-E power modules are plugged into the TM-P terminal modules provided for the purpose. The first module after the IM 151-3 must be a power module. The version for fusing has a fusible link (5 x 20 mm). Up to 6 replacement fuses can be stored in the terminating module (see IM 151).

Possible combinations of the TM-E terminal modules and power modules


Power modules Screw-type terminal Order No. 6ES7 193 Spring-loaded terminal Order No. 6ES7 193 Fast Connect Order No. 6ES7 193 PM-E 24 V DC PM-E 24 48 V DC PM-E 24 ... 48 V DC/24 ... 230 V AC PM-E F 24 V DC PROFIsafe PM-D F 24 V DC PROFIsafe TM-P terminal modules for power modules 15S23-A1 4CC20-0AA0 15C23-A1 4CC30-0AA0 15N23-A1 4CC70-0AA0
n n n

15S23-A0 4CD20-0AA0 15C23-A0 4CD30-0AA0 15N23-A0 4CD70-0AA0


n n n

15S22-01 4CE00-0AA0 15C22-01 4CE10-0AA0 15N22-01 4CE60-0AA0


n n n

30S44-A0 4CK20-0AA0 30C44-A0 4CK30-0AA0 -

F30S47-F0 3RK1903-3AA0 -

n n

Possible combinations of the electronics modules and power modules


Power modules PM-E DC 24 V Electronic modules Can be used for all electronics modules except 2 DI 120 V AC ST, 2 DI 230 V AC ST and 2 DO 120/230 V AC Can be used for all 15 mm-wide electronics modules except 2 DI 120 V AC ST, 2 DI 230 V AC ST and 2 DO 120/230 V AC as well as for 4 DI 24 48 V UC in AC operation Can be used with all 15 mm-wide electronic modules See Manual "ET 200S fail-safe modules" in the documentation packages "S7 F Systems" and "S7 Distributed Safety"

PM-E DC 24 ... 48 V

PM-E DC 24 ... 48 V/AC 24 ... 230 V PM-E F pp DC 24 V PROFIsafe PM-D F pm DC 24 V PROFIsafe

Siemens IK PI 2009

5/29

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Power modules for PM-E electronic modules

Technical specifications
Order No. Power supply Current carrying capacity Current carrying capacity to 60 C, 10 A max. Voltages and currents Load voltage L+ Rated value (DC) Short-circuit protection 24 V No; external (e.g. automatic circuit breaker), tripping characteristic C Yes 4 mA 0.1 W 3 bytes 6ES7 138-4CA01-0AA0 Order No. Power supply Current carrying capacity Current carrying capacity to 60 C, 10 A max. Voltages and currents Load voltage L+ Rated values Short-circuit protection 24 to 48 V DC No; external (e.g. automatic circuit breaker), tripping characteristic B, C Yes 12 mA 500 W; mW 3 bytes 6ES7 138-4CA50-0AB0

reverse polarity protection Current consumption from load voltage 1L+ (without load), max. Power loss, typ. Parameter Remark Status information/ alarms/diagnostics Diagnoses Diagnostics missing load voltage Diagnostics indication LED Rated load voltage PWR (green) Collective error SF (red) Isolation Isolation checked with Isolation primary/secondary

reverse polarity protection Current consumption from load voltage 1L+ (without load), max. Power loss, typ. Parameter Remark Status information/alarms/diagnostics Diagnoses

Yes Yes Yes Yes 500 VDC Yes; between rated load voltage and backplane bus, between power modules

Diagnostics missing load voltage Diagnostics indication LED Rated load voltage PWR (green) Collective error SF (red) Isolation Isolation checked with Isolation primary/secondary

Yes Yes Yes Yes 500 VDC Yes; between rated load voltage and backplane bus, between power modules

Dimensions Dimensions Width Height Depth Weights Weight, approx. 35 g 15 mm 81 mm 52 mm

Dimensions Dimensions Width Weights Weight, approx. 35 g 15 mm

5/30

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Power modules for PM-E electronic modules

Ordering data
PM-E 24 V DC power module 1) for electronic modules; with diagnostics 24 48 V DC PM-E power module for electronic modules; with diagnostics, with status bit "load voltage" present Power module PM-E 24 48 V, 42 230 V AC for electronic modules; with diagnostics and fuse

Order No. 6ES7 138-4CA01-0AA0 Accessories Label sheets DIN A4 (10 pieces) 6ES7 138-4CA50-0AB0 Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red 6ES7 138-4CB11-0AB0 yellow light beige
1)

Order No.

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0

Can be used for all electronic and technology modules except 2 DI 120 V AC / 2 DI 230 V AC / 2 DO 120/230 V AC

Selection tool for terminal modules


Power modules Screw-type terminal type designation Order No. 6ES7 193... Spring-loaded terminal type designation Order No. 6ES7 193... FastConnect type designation Order No. 6ES7 193... PM-E 24 V DC PM-E 24 48 V DC PM-E 24 V DC/120/230 V AC PM-E F 24 V DC PROFIsafe TM-P terminal modules for power modules TM-P15S23-A1 4CC20-0AA0 TM-P15C23-A1 4CC30-0AA0 TM-P15N23-A1 4CC70-0AA0
n n n

TM-P15S23-A0 4CD20-0AA0 TM-P15C23-A0 4CD30-0AA0 TM-P15N23-A0 4CD70-0AA0


n n n

TM-P15S22-01 4CE00-0AA0 TM-P15C22-01 4CE10-0AA0 TM-P15N22-01 4CE60-0AA0


n n n

TM-P30S44-A0 4CK20-0AA0 TM-P30C44-A0 4CK30-0AA0 Available soon

Siemens IK PI 2009

5/31

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

Power modules for PM-E SIPLUS electronics modules (extended temperature range)
Power module PM-E 24 V DC Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 138-4CA01-2AA0 6ES7 138-4CA01-0AA0 -25 +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Power module PM-E 24 to 48 V DC Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 138-4CA50-2AB0 6ES7 138-4CA50-0AB0 -25 +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Power module PM-E 24 to 48 V DC / 42 to 230 V AC Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 138-4CB11-2AB0 6ES7 138-4CB11-0AB0 -25 +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical specifications

For monitoring and, depending on the version, fusing the load and sensor supply voltage Can be plugged onto TM-P terminal modules with automatic coding. Diagnostics message for voltage and blown fuse (can be switched off via configuration) Fail-safe PM-E F PROFIsafe power module for safe switching off of sequentially plugged-in 24 V DC to 10 A digital output modules or external loads; 3 additional integrated fail-safe 24 V DC / 2 A outputs PM-E 24 to 48 V DC - with status information and diagnostics "Load voltage present - for option handling PM-E 24 V DC to 230 V AC - power module for universal use - for option handling

Technical specifications

Technical specifications

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Ordering data
Power module PM-E SIPLUS (extended temperature range and medium load) Power module PM-E 24 V DC 1) For electronics modules; with diagnostics Power module PM-E 24 to 48 V DC For electronic modules; with diagnostics; with status bit "load voltage" present Power module PM-E 24 to 48 V DC, 24 to 230 V AC For electronic modules; with diagnostics and fuse Accessories

Order No.

6AG1 138-4CA01-2AA0

6AG1 138-4CA50-2AB0

6AG1 138-4CB11-2AB0

see Power modules for PM-E electronic modules ordering data

1)

Can be used for all electronics and technology modules except 2 DI 120 V AC / 2 DI 230 V AC / 2 DO 120/130 V AC

5/32

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Reserve module

Overview

Technical specifications
Order No. Current consumption Power loss, typ. Parameter Remark according to configured module according to configured module 0.025 W 0.025 W 6ES7 1384AA01-0AA0 6ES7 1384AA11-0AA0

Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Dimensions Dimensions Width Height Depth Weights Weight, approx. 33 g Order No. 55 g 15 mm 81 mm 52 mm 30 mm 81 mm 52 mm No No No No

Applicable only on IM 151-1 Standard interface modules as of 6ES7151-1AA04-0AB0 and IM 151-1 High Feature as of 6ES7151-1BA02-0AB0 Suitable for all TM-E terminal modules (15 mm and 30 mm construction width) Reserves one slot for any electronic module. The reserve module is inserted into the reserved slot of the ET 200S configuration. Terminal module can be wired up for the function to be used later The reserve module has no connection to the terminals of the TM-E terminal module. The TM-E terminal module can therefore by completely wired up and prepared for its future purpose. Parameterizable diagnostic response with IM 151-1 STANDARD and IM 151-1 HIGH FEATURE Facilitates retroffiting of I/O modules during operation Options can be released via the PLC program without the need for re-engineering

Ordering data
Reserve modules for ET 200S for reserving unused slots 15 mm overall width (5 units) 30 mm overall width (1 unit)

6ES7 138-4AA01-0AA0 6ES7 138-4AA11-0AA0

Siemens IK PI 2009

5/33

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

Potential isolation module

Technical specifications
Potential isolation module Module-specific specifications Supported synchronous operation Number of outputs Cable length Unshielded Shielded Parameter length Voltages, Currents, Potentials Nominal load voltage L+ (from power module) Polarity reversal protection Total current of the outputs (per module) Potential isolation Between the channels Between the channels and backplane bus Permissible potential difference Between the supply voltage and the backplane bus Isolation tested Between the supply voltage and the backplane bus Diagnostic alarm Data for selecting an actuator Short-circuit protection for the output Dimensions and weight Dimensions W H D (mm, the total dimensions depend on the selected terminal module) Weight 15 x 81 x 52 No, possible via PM-E or external 500 V DC, 1500 V AC no 75 V DC, 240 V AC no Yes 24 48 V DC; 24 AC 230 V no max. 10 A Assignment L L M M AUX1 AUX1 Terminal 5 6 7 8 A8 A7 Assignment L L M M AUX1 AUX1 max. 600 m max. 1000 m 1 byte no 4 6ES7138-4FD00-0AA0

Potential isolation module with 4 outputs Output current 5 A per output / 10 A per module Nominal load voltage: According to the load voltage on the power module of this load voltage group Is suitable for all terminal modules TM-E (construction width 15 mm)

Design
Pin assignments for 4POTDIS (6ES7138-4FD00-0AA0) Terminal 1 2 3 4 A4 A3
Explanations:

L:

Load voltage according to terminal 2, 6 of the PM-E

M: Potential according to terminal 3, 7 of the PM-E AUX1: Ground connection or potential rails (optional to 230 V AC)

Approx. 33 g Order No. 6ES7138-4FD00-0AA0

Ordering data
Potential isolation module for ET 200S for preparing the load voltage on additional terminals, 15 mm construction width, 1 piece Accessories for labeling Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0

5/34

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Digital electronic modules

Overview
2, 4 and 8-channel digital inputs and outputs for the ET 200S Can be plugged onto TM-E terminal modules with automatic coding. High-feature versions for enhanced plant availability, additional functions and comprehensive diagnostics Hot swapping of modules possible

Design
Different potentials are available on the terminals depending on the selected terminal module.

Possible combinations of the TM-E terminal modules and digital modules


Electronic modules Screw-type terminal Order No. 6ES7 193 Spring-loaded terminal Order No. 6ES7 193 Fast Connect Order No. 6ES7 193 2DI 24 V DC ST 2DI 24 V DC HF 4DI 24 V DC ST 4DI 24 V DC HF 4DI 24 V DC /SRC ST 4DI 24 48 V UC HF 4 DI NAMUR 8 DI 24 V DC, ST 8 DI, 24 VDC ST source input 2 DI 120 V AC ST 2 DI 230 V AC ST 2 DO 24 V DC/0.5 A ST 2 DO 24 V DC/0.5 A HF 4 DO 24 V DC/0.5 A ST 4 DO, 24 VDC / 0.5 A ST sink output 8 DO 24 V DC/0.5 A ST 8 DO, 24 VDC / 0.5 A ST sink output 2 DO 24 V DC/2 A ST 2 DO 24 V DC/2 A HF 4 DO 24 V DC/2 A ST 2 DO 24 230 V AC/2 A 2RO NO 24 120 V DC/5 A 24 230 V AC/5 A 2RO NO/NC 24 48 V DC/5 A 24 230 V AC/5 A TM-E terminal modules for electronics modules 15S26-A1 15C26-A1 15N26-A1
n

15S24-A1 15C24-A1 15N24-A1


n

15S24-01 15C24-01 15N24-01


n

15S23-01 15C23-01 15N23-01


n

15S24-AT 15C24-AT -

30S44-01 30C44-01 -

30S46-A1 30C46-A1 -

4CA40-0AA0 4CA20-0AA0 4CB20-0AA0 4CB00-0AA0 4CL20-0AA0 4CG20-0AA0 4CF40-0AA0 4CA50-0AA0 4CA30-0AA0 4CB30-0AA0 4CB10-0AA0 4CL30-0AA0 4CG30-0AA0 4CF50-0AA0 4CA80-0AA0 4CA70-0AA0 4CB70-0AA0 4CB60-0AA0

5
n n n n n n n n n n n n

n n n

n n n

n n n

n n n

n n

n n

n n

n n

Siemens IK PI 2009

5/35

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Digital electronic modules

Technical specifications
Order No. Supply voltages Rated value DC 24 V Reverse polarity protection Current consumption from backplane bus 3.3 V DC, max. 10 mA from supply voltage L+, max. Power loss, typ. Address area Address space per module with packing without packing Isochronous mode 2 Bit 1 Byte 2 Bit 1 Byte 4 Bit 1 Byte 4 Bit 1 Byte 4 Bit 1 Byte 1 Byte Yes; TWE = 3000 us 2 2 4 4 4 8 8 Dependent on encoder 0.4 W 10 mA Dependent on encoder 0.4 W 10 mA Dependent on encoder 0.7 W 10 mA Dependent on encoder 0.7 W Dependent on encoder 0.7 W 10 mA Dependent on encoder 1.2 W Yes; From power module Yes Yes; From power module Yes Yes; From power module Yes Yes; From power module Yes Yes; From power module Yes Yes Yes 6ES7 1314BB01-0AA0 6ES7 1314BB01-0AB0 6ES7 1314BD01-0AA0 6ES7 1314BD01-0AB0 6ES7 1314BD51-0AA0 6ES7 1314BF00-0AA0

Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - programmable - at " to "1", min. - at "0" to "1", max. - at "1" to "0", min. - at "1" to "0", max. Encoder supply Number of outputs Output voltage Output current, rated value Output current, permissible range Short-circuit protection min. L+ (-0.5 V), under load 500 mA 0 to 500 mA min. L+ (-0.5 V), under load 500 mA 0 to 500 mA Yes; electronic min. L+ (-0.5 V), under load 500 mA 0 to 500 mA min. L+ (-0.5 V), under load 500 mA 0 to 500 mA Yes; electronic max. M +0.5 V, under load 500 mA 0 to 500 mA No 2 ms; typically 3 ms 4.5 ms 2 ms; typically 3 ms 4.5 ms Yes; 0.1 / 0.5 / 3 / 15 ms 0.05 / 0.4 / 2.7 / 14.85 0.15 / 0.6 / 3.3 / 15.15 0.05 / 0.4 / 2.7 / 14.85 No 2 ms; typically 3 ms 4.5 ms 2 ms; typically 3 ms 4.5 ms Yes; 0.1 / 0.5 / 3 / 15 ms 0.05 / 0.4 / 2.7 / 14.85 0.15 / 0.6 / 3.3 / 15.15 0.05 / 0.4 / 2.7 / 14.85 0.15 / 0.6 / 3.3 / 15.15 No 2 ms; typically 3 ms 4.5 ms 2 ms; typically 3 ms 4.5 ms 7 mA; at 24 V 8 mA 7 mA; at 24 V 8 mA 7 mA; at 24 V 24 V -30 to +5 V 15 to 30 V 24 V -30 to +5 V 11 to 30 V 24 V -30 to +5 V 15 to 30 V 24 V -30 to +5 V 11 to 30 V 24 V -5 to +30 V -15 to -30 V 1 000 m 600 m Yes 1 000 m 600 m Yes 1 000 m 600 m Yes 1 000 m 600 m Yes 1 000 m 600 m Yes

1 000 m 600 m Yes; 2-wire sensors connectable 24 V -30 to +5 V 15 to 30 V 5 mA

No 2 ms 4.5 ms 2 ms 4.5 ms

0; no encoder supply

5/36

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Digital electronic modules

Technical specifications (continued)


Order No. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Parameter Remark 1 byte 3 bytes 1 byte 3 bytes 1 byte 3-byte parameter (not accessible for the user) Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA 6ES7 1314BB01-0AA0 6ES7 1314BB01-0AB0 6ES7 1314BD01-0AA0 6ES7 1314BD01-0AB0 6ES7 1314BD51-0AA0 6ES7 1314BF00-0AA0

Diagnosis: short circuit Status information/ alarms/diagnostics Diagnoses Diagnostic functions Short circuit No

Disable/enable

Disable/enable

Yes Yes; Short-circuit to M, module by module

No

Yes Yes; Short-circuit to M, module by module

No

No

Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Supply voltages Rated value DC 24 V Yes; From power module 48 V Yes Yes; from power module Yes 48 V Yes; AC or DC automatic Yes Yes Yes; From power module 35 g 6ES7 1314CD00-0AB0 35 g 6ES7 1314EB00-0AB0 35 g 35 g 6ES7 1314FB00-0AB0 35 g 6ES7 1314RD00-0AB0 35 g 6ES7 1314BF50-0AA0 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 75 VDC / 60 VAC 75 VDC / 60 VAC 75 VDC / 60 VAC 75 VDC / 60 VAC 75 VDC / 60 VAC 75 VDC / 60 VAC No Yes No Yes No Yes No Yes No Yes No Yes 500 VDC 500 VDC 500 VDC 500 VDC 500 VDC 500 VDC No Yes No Yes No Yes; Per channel Yes; Per channel Yes; Per channel Yes; Per channel Yes; Per channel Yes

permissible range, lower limit (DC) 24 V permissible range, upper limit (DC) AC 24 V AC 120 V AC 230 V permissible range, lower limit (AC) 24 V permissible range, upper limit (AC) Reverse polarity protection

Siemens IK PI 2009

5/37

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Digital electronic modules

Technical specifications (continued)


Order No. Current consumption from backplane bus 3.3 V DC, max. 10 mA from supply voltage L+, max. Power loss, typ. Address area Address space per module with packing without packing Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of NAMUR inputs Number of simultanneously controllable inputs Cable length cable length, shielded, max. Cable length unshielded, max. Parallel switching of inputs Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, AC Rated value, DC Rated value, UC for signal "0" for signal "1" 24 V; 24 to 48 V UC -6 to 6 V DC, 0 to 5 V AC -15 to -57.6 V DC; -15 to 57.6 V DC; 15 to 48 V AC 47 to 63 Hz 10 mA; 4 to 10 mA 0 to 20 V AC 79 to 132 V AC 0 to 40 V AC 164 to 264 V AC 30 to -5 V 164 to 264 V AC 120 V 230 V 24 V Yes Yes Yes 1 000 m 600 m 1 000 m 600 m 1 000 m 600 m No Yes 200 m 1 000 m 600 m 4 2 2 4 4 8 Yes No No Yes 4 Bit 1 Byte 2 Bit 1 Byte 2 Bit 1 Byte 4 Bit 1 Byte Dependent on encoder 0.7 W 0.5 W 0.7 W 6 mA 6 mA Dependent on encoder 1.6 W Dependent on encoder 1.2 W 6ES7 1314CD00-0AB0 6ES7 1314EB00-0AB0 6ES7 1314FB00-0AB0 6ES7 1314RD00-0AB0 6ES7 1314BF50-0AA0

Frequency range Input current for signal "1", typ. for 10 k switched contact - for signal "0" - for signal "1" for unswitched contact - for signal "0", max. (permissible quiescent current) - for signal "1" for NAMUR encoders - for signal "0" - for signal "1" Input delay (for rated value of input voltage) for standard inputs - programmable - at " to "1", min. - at "0" to "1", max. - at "1" to "0", min. - at "1" to "0", max.

47 to 63 Hz 3 mA; 3 to 9 mA

47 to 63 Hz 5 mA; 5 to 15 mA 0.35 to 1.2 mA 2.1 to 7 mA 0.5 mA typ. 8 mA 0.35 mA to 1.2 mA 2.1 mA to 7 mA 6 mA; At 24 V

No 15 ms 15 ms 25 ms 15 ms 45 ms 4.6 s 15 ms 4.6 s 2 ms 4.5 ms 2 ms 4.5 ms

5/38

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Digital electronic modules

Technical specifications (continued)


Order No. Encoder connection Fixed current limitation for wire break monitoring, min. 18 k; Rated voltage 24 V (15 V to 35 V); rated voltage 48 V (30 V to 60 V): 39 kohms 1 min. L+ (-0.5 V), under load 500 mA 0 to 500 mA Yes; per module Yes; electronic min. 8.2 V, loaded 45 mA 6ES7 1314CD00-0AB0 6ES7 1314EB00-0AB0 6ES7 1314FB00-0AB0 6ES7 1314RD00-0AB0 6ES7 1314BF50-0AA0

Encoder supply Number of outputs Output voltage Output current, rated value Output current, permissible range Short-circuit protection Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Yes 2 mA; (0.5 to 2 mA), a minimum load current is necessary for wire break diagnostics. No 1 mA No 2 mA Yes 1.5 mA

Parameter Remark Status information/ alarms/diagnostics Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostic information readable Short circuit Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between different circuits between M internally and the inputs Dimensions Dimensions Width Height Depth Weights Weight, approx. 35 g 31 g 31 g 35 g 35 g 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 75 VDC / 60 VAC 1500 V AC 1500 V AC 75 VDC / 60 VAC 75 VDC / 60 VAC No Yes No Yes No Yes No Yes Yes No Yes 2500 V DC 2500 V DC 4000 VDC 500 VDC Yes Yes; Per channel Yes; Per channel Yes; Per channel Yes Yes; Per channel No Yes; Per channel No No Yes; parameterizable No No Yes; Diagnostic alarm Yes No Yes; can be set No 3 bytes 3 bytes 12 bytes 3 bytes

Siemens IK PI 2009

5/39

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Digital electronic modules

Technical specifications (continued)


Order No. Voltages and currents Reverse voltage protection Yes; when using the same load voltage as on the power module 24 V; From power module Yes; polarity reversal can lead to the digital outputs being connected through 5 mA; Per channel 0.4 W Yes; when using the same load voltage as on the power module 24 V; From power module Yes; polarity reversal can lead to the digital outputs being connected through 5 mA; per module 10 mA 0.4 W Yes; when using the same load voltage as on the power module 24 V; From power module Yes; polarity reversal can lead to the digital outputs being connected through 5 mA; Per channel 10 mA 1.4 W Yes; when using the same load voltage as on the power module 24 V; From power module Yes; polarity reversal can lead to the digital outputs being connected through 5 mA; Per channel 10 mA 1.4 W Yes; when using the same load voltage as on the power module 24 V Yes; polarity reversal can lead to the digital outputs being connected through 10 mA; Per channel 10 mA 0.8 W Yes 6ES7 1324BB01-0AB0 6ES7 1324BB01-0AA0 6ES7 1324BB31-0AB0 6ES7 1324BB31-0AA0 6ES7 1324BD02-0AA0 6ES7 1324BF00-0AA0

Load voltage L+ Rated value (DC) reverse polarity protection 24 V Yes

Current consumption from load voltage L+ (without load), max. 5 mA; Per channel 10 mA 1.5 W

from backplane bus 3.3 V DC, max. 10 mA Power loss, typ. Address area Address space per module with packing without packing Isochronous mode Isochronouos mode Digital inputs Cable length cable length, shielded, max. Cable length unshielded, max. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load "0" to "1", max. "1" to "0", max. 100 s 400 s 0.5 A 7 mA 600 mA L+ (-1 V) 2 1 000 m 600 m 1.5 A -55 to -60 V, typ. L+( ) 2.5 W Yes Yes 2 Bit 1 Byte

2 Bit 1 Byte No

2 Bit 1 Byte Yes

2 Bit 1 Byte No

4 Bit 1 Byte Yes 1 Byte Yes; jitter incumbered < 100us

1 000 m 600 m 2 1 000 m 600 m 0.7 to 1.8 A -55 to -60 V, typ. L+( ) 5W Yes L+ (-1 V) 0.5 A 7 mA 600 mA 0.3 mA 200 s 1.3 ms 2 1 000 m 600 m 4A -55 to -60 V, typ. L+( ) 5W Yes L+ (-1 V) 2A 7 mA 2.4 A 0.5 mA 100 s 400 s 2 1 000 m 600 m 2.8 to 7.2 A -55 to -60 V, typ. L+( ) 10 W Yes L+ (-1 V) 2A 7 mA 2.4 A 0.5 mA 200 s 1.3 ms 5W Yes L+ (-1 V) 0.5 A 7 mA 600 mA 0.3 mA 45 s 90 s 4 1 000 m 600 m 8 1 000 m 600 m Yes; Per channel o.k. o.k. 5W Yes o.k. 0.5 A 7 mA 600 mA 0.3 mA 300 s 600 s

Short-circuit protection of the output Yes; Per channel Yes; Per channel Yes; Per channel Yes; Per channel Yes

for signal "0" residual current, max. 0.3 mA

5/40

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Digital electronic modules

Technical specifications (continued)


Order No. Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. up to 60 C, max. Load impedance range lower limit upper limit Parameter Remark 3 bytes 1 byte 3 bytes 1 byte 1 byte 3-byte parameter (not accessible for the user) 48 3 400 48 3 400 12 3 400 12 3 400 48 3 400 48 3 400 100 Hz 2 Hz 10 Hz 1A 100 Hz 2 Hz 10 Hz 1A 100 Hz 2 Hz; 0.5 H 10 Hz 4A 100 Hz 2 Hz; 0.5 H 10 Hz 4A 800 Hz 2 Hz 10 Hz 2A 100 Hz 2 Hz 10 Hz 4A No Yes; Per module No Yes; Per module No Yes; Per module No Yes; Per module No Yes; Per module No Yes 6ES7 1324BB01-0AB0 6ES7 1324BB01-0AA0 6ES7 1324BB31-0AB0 6ES7 1324BB31-0AA0 6ES7 1324BD02-0AA0 6ES7 1324BF00-0AA0

Diagnosis: wire break Diagnosis: short circuit Behavior on CPU/Master STOP, channel-wise Status information/ alarms/diagnostics Substitute values connectable Diagnoses Diagnostic functions Wire break Short circuit Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Isolation Isolation checked with Isolation Isolation, digital outputs between the channels between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx.

Disable/enable Disable/enable Substitute a value / keep last value

Disable/enable Disable/enable Substitute a value / keep last value

Yes; 0/1 Yes; can be read out Yes; channel by channel Yes; channel by channel Yes Yes Yes No

Yes; 0/1 Yes; can be read out Yes; channel by channel Yes; channel by channel Yes Yes Yes Yes Yes No No No

500 VDC

500 VDC

500 VDC

500 VDC

500 VDC

No Yes

No Yes

No Yes

No Yes

No Yes

No Yes

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

Siemens IK PI 2009

5/41

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Digital electronic modules

Technical specifications (continued)


Order No. Voltages and currents Reverse voltage protection Yes; When using the same load voltage as Yes; when using the same voltage source as on the power module Yes; When using the same correctly polarized load voltage as on the power module 24 V; From power module Yes 30 mA 10 mA 0.6 W 24 V; From power module Yes 30 mA 10 mA 0.6 W 24 V; From power module Yes 5 mA 10 mA 1.5 W Yes 6ES7 1324BD32-0AA0 6ES7 1324FB01-0AB0 6ES7 1324HB01-0AB0 6ES7 1324HB10-0AB0 6ES7 1324BF50-0AA0 6ES7 1324BD50-0AA0

Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area 10 mA; Per channel 1.6 W 30 mA 18 mA 4W 5 mA; Per channel 10 mA 0.8 W 24 V; From power module Yes 24 V; From power module Yes 24 V; From power module Yes

from backplane bus 3.3 V DC, max. 10 mA

Address space per module with packing without packing Isochronous mode Isochronouos mode Digital inputs Cable length cable length, shielded, max. Cable length unshielded, max. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. 4 1 000 m 600 m 2 1 000 m 600 m 2 1 000 m 600 m No; external fusing, max. 6 A quick-acting no 2 1 000 m 600 m No; external fusing, max. 6 A quick-acting no 8 1 000 m 600 m Yes; Per channel Yes; Per channel 4 1 000 m 600 m Yes No No Yes Yes 4 Bit 1 Byte 2 Bit 1 Byte 2 Bit 1 Byte 2 Bit 1 Byte 1 Byte 4 Bit 1 Byte

Short-circuit protection of the output Yes; Per channel Yes; via fuse in power module Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. for signal "1" minimum load current for signal "0" residual current, max. 0.5 mA Output delay with resistive load "0" to "1", max. "1" to "0", max. Parallel switching of 2 outputs for increased power for redundant control of a load No Yes; Per module No Yes; Per module 50 s; Typically 45s 120 s; Typically 90s 15 ms 15 ms 3 mA 2A 7 mA 2.4 A 2A 0.1 mA 2.2 A L+ (-1.5 V) Typically L+ (-55 to -60 V) 10 W Yes -55 to -60 V 100 W Yes; possible

Typ. 47 V 5W 5W Yes 1V 0.5 A 5 mA 700 mA

Yes

Yes

Yes Max. 1 V 0.5 A 5 mA 700 mA

8 mA

8 mA 5 A 300 s 600 s 5 A 300 s 600 s

No No

No No

No Yes; Per module

No Yes; Per module

5/42

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Digital electronic modules

Technical specifications (continued)


Order No. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. up to 40 C, max. up to 50 C, max. up to 60 C, max. Load impedance range lower limit upper limit Relay outputs Switching capacity of the contacts Thermal continuous current, max. Parameter Remark Behavior on CPU/Master STOP, channel-wise Status information/alarms/diagnostics Substitute values connectable Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital output (green) Isolation Isolation checked with tested with Channels against backplane bus and load voltage L+ Load voltage L+ against backplane bus Isolation Isolation, digital outputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Dimensions Dimensions Width Height Depth Weights Weight, approx. 40 g 37 g 50 g 50 g 40 g 40 g 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm No Yes No Yes Yes Yes Yes Yes Yes Yes No Yes No Yes 1500 V AC 500 V DC 2500 V DC 500 V DC 2500 V DC 500 VDC 500 VDC Yes Yes Yes Yes Yes Yes No No No No No No Yes; 0/1 Yes; 0/1 1 byte 3 bytes Substitute a value/keep last value, 0/1 3 bytes Substitute a value / keep last value 3 bytes 3 bytes 1 byte 5A 5A 12 3 400 48 3 400 48 3 400 4A 4 A; At 55C and 24VDC 2A 1.5 A 1A 4A 2A 1 000 Hz 2 Hz; At 0.5H 10 Hz 10 Hz 0.5 Hz 1 Hz 2 Hz 0.5 Hz 2 Hz 2 Hz 0.5 Hz 2 Hz 100 Hz 0.5 Hz 10 Hz 100 Hz 0.5 Hz 10 Hz 6ES7 1324BD32-0AA0 6ES7 1324FB01-0AB0 6ES7 1324HB01-0AB0 6ES7 1324HB10-0AB0 6ES7 1324BF50-0AA0 6ES7 1324BD50-0AA0

Siemens IK PI 2009

5/43

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Digital electronic modules

Ordering data
Digital input modules Ordering unit 5 items 2 DI 24 V DC Standard 2 DI 24 V DC High Feature 4 DI 24 V DC Standard 4 DI 24 V DC High Feature 2 DI 120 V AC 2 DI 230 V AC 4 DI 24 48 V UC 4 DI 24 V DC SOURCE INPUT Ordering unit 1 item 4 DI 24 V DC NAMUR 8 DI 24 V DC Standard 8 DI, 24 VDC, standard SOURCE INPUT

Order No. Digital output modules Ordering unit 5 items 6ES7 131-4BB01-0AA0 6ES7 131-4BB01-0AB0 6ES7 131-4BD01-0AA0 6ES7 131-4BD01-0AB0 6ES7 131-4EB00-0AB0 6ES7 131-4FB00-0AB0 6ES7 131-4CD00-0AB0 6ES7 131-4BD51-0AA0 6ES7 131-4RD00-0AB0 6ES7 131-4BF00-0AA0 6ES7 131-4BF50-0AA0 2 DO 24 V DC/0.5 A Standard 2 DO 24 V DC/0.5 A High Feature 2 DO 24 V DC/2 A Standard 2 DO 24 V DC/2 A High Feature 4 DO 24 V DC/0.5 A Standard 4 DO, 24 VDC / 0.5 A, standard SOURCE OUTPUT 4 DO 24 V DC/2 A Standard 2 DO 24 230 V AC/1 A 2 DO 24 V DC 230 V AC/ 5 A relay, NO contact 2 DO 24 48 V DC 230 V AC/ 5 A relay, changeover contact Ordering unit 1 item 8 DO 24 V DC/0.5 A Standard 8 DO, 24 VDC / 0.5 A, standard SOURCE OUTPUT Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige

Order No.

6ES7 132-4BB01-0AA0 6ES7 132-4BB01-0AB0 6ES7 132-4BB31-0AA0 6ES7 132-4BB31-0AB0 6ES7 132-4BD02-0AA0 6ES7 132-4BD50-0AA0 6ES7 132-4BD32-0AA0 6ES7 132-4FB01-0AB0 6ES7 132-4HB01-0AB0 6ES7 132-4HB10-0AB0

6ES7 132-4BF00-0AA0 6ES7 132-4BF50-0AA0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0

5/44

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

SIPLUS digital electronics modules (extended temperature range)

Overview
Digital output modules SIPLUS 2 DO 24 V DC/ 2A High Feature Order No. Order No. based on Ambient temperature range 6AG1 1324BB31-7AB0 6ES7 1324BB31-0AB0 -25 to +70 C; condensation permissible Digital output modules SIPLUS 4 DO 24 V DC/ 0.5 A Standard 6AG1 1324BD01-2AA0 6ES7 1324BD01-0AA0 -25 to +60 C; condensation permissible

Environmental conditions

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Digital output modules SIPLUS 4 DO 24 V DC/ 2 A Standard Digital output modules SIPLUS 2 DO 24 V DC to 230 V AC/ 0.5 A relay, NO contact 6AG1 1324HB01-2AB0 6ES7 1324HB01-0AB0

Technical data

2- and 4-channel digital inputs and outputs for the ET 200S Can be plugged onto TM-E terminal modules with automatic coding. High-feature versions for enhanced plant availability, additional functions and comprehensive diagnostics Hot swapping of modules possible
Digital input modules SIPLUS 4 DI 24 V DC Standard Order No. Order No. based on Ambient temperature range 6AG1 1314BD01-2AA0 6ES7 1314BD01-0AA0 -25 to +60 C; condensation permissible Digital input modules SIPLUS 8 DI 24 V DC Standard 6AG1 1314BF00-7AA0 6ES7 1314BF00-0AA0 -25 to +70 C; condensation permissible Technical data Order No. Order No. based on Ambient temperature range Environmental conditions

6AG1 1324BD32-2AA0 6ES7 1324BD32-0AA0

-25 to +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Digital output modules SIPLUS 2 DO 24 to 48 V DC to 230 V AC/2 A relay, changeover contact Digital output modules SIPLUS 8 DO 24 V DC/ 0.5 A Standard

Environmental conditions

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Digital output modules SIPLUS 4 DO 24 V DC/ 0.5 A High Feature Digital output modules SIPLUS 4 DO 24 V DC/ 0.5 A Standard 6AG1 1324BD02-7AA0 6ES7 1324BD02-0AA0 -25 to +70 C; condensation permissible

Technical data

Order No. Order No. based on Ambient temperature range

6AG1 1324HB10-2AB0 6ES7 1324HB10-0AB0 -25 to +60 C; condensation permissible

6AG1 1324BF00-7AA0 6ES7 1324BF00-0AB0 -25 to +70 C; condensation permissible

Order No. Order No. based on Ambient temperature range

6AG1 1324BB01-2AB0 6ES7 1324BB01-0AB0 -25 to +60 C; condensation permissible

Environmental conditions

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

Environmental conditions

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Siemens IK PI 2009

5/45

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

SIPLUS digital electronics modules (extended temperature range)

Ordering data
SIPLUS digital input modules (extended temperature range and medial exposure) Ordering unit: 1 unit 4 DI 24 V DC Standard 8 DI 24 V DC Standard SIPLUS digital output modules (extended temperature range and medial exposure) Ordering unit: 5 units 2 DO 24 V DC/0.5 A High Feature 2 DO 24 V DC/2 A High Feature 4 DO 24 V DC/0.5 A Standard 4 DO 24 V DC/0.5 A Standard 4 DO 24 V DC/2 A Standard 2 DO 24 V DC to 230 V AC/ 5 A relay, NO contact

Order No.

6AG1 131-4BD01-2AA0 6AG1 131-4BF00-7AA0

6AG1 132-4BB01-2AB0 6AG1 132-4BB31-7AB0 6AG1 132-4BD01-2AA0 6AG1 132-4BD02-7AA0 6AG1 132-4BD32-2AA0 6AG1 132-4HB01-2AB0 6AG1 132-4HB10-2AB0

2 DO 24 to 48 V DC to 230 V AC/5 A relay, changeover contact Ordering unit: 1 unit 8 DO 24 V DC/5 A Standard Accessories

6AG1 132-4BF00-0AA0 see Digital electronic modules ordering data

5/46

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Overview
Analog inputs and outputs for the ET 200S Can be plugged onto TM-E terminal modules with automatic coding High-feature variants with enhanced performance, precision and resolution High-speed variants with extremely fast, isochronous cycle times. Hot swapping of modules possible Note: Consult the configuring guide for selection of the appropriate TM-E terminal modules.

Design
Possible combinations of the TM-E terminal modules and analog modules
Electronic modules Screw-type terminal Order No. 6ES7 193 Spring-loaded terminal Order No. 6ES7 193 Fast Connect Order No. 6ES7 193 2 AI U ST 2 AI U HF 2 AI U HS 2 AI I 2WIRE ST 2 AI I 2WIRE HS 4 AI I 2WIRE ST 2 AI I 2/4WIRE HF 2 AI I 4WIRE ST 2 AI I 4WIRE HS 2 AI RTD ST 2 AI RTD HF 2 AI TC ST 2 AI TC HF 2 AO U ST 2 AO U HF 2 AO U HS 2 AO I ST 2 AO I HF 2 AO I HS 4 IQ-SENSE
n n

Terminalmodule TM-E fr Elektronikmodule 15S26-A1 15C26-A1 15N26-A1


n

5
15S24-AT 15C24-AT 30S44-01 30C44-01 30S46-A1 30C46-A1 -

15S24-A1 15C24-A1 15N24-A1


n

15S24-01 15C24-01 15N24-01


n

15S23-01 15C23-01 15N23-01


n

4CA40-0AA0 4CA20-0AA0 4CB20-0AA0 4CB00-0AA0 4CL20-0AA0 4CG20-0AA0 4CF40-0AA0 4CA50-0AA0 4CA30-0AA0 4CB30-0AA0 4CB10-0AA0 4CL30-0AA0 4CG30-0AA0 4CF50-0AA0 4CA80-0AA0 4CA70-0AA0 4CB70-0AA0 4CB60-0AA0

n n n

n n n

n n n n n

n n n n n n

Siemens IK PI 2009

5/47

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Short-circuit protection reverse polarity protection Voltage supply to the transducers present short-circuit proof Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module 30 mA 55 mA 10 mA 0.85 W 80 mA 10 mA 0.6 W 225 mA 10 mA 2.5 W No Yes Yes Yes Yes Yes; Destruction limit 35 mA per channel 24 V; From power module 24 V 24 V; From power module 24 V Yes Yes 6ES7 134-4FB01-0AB0 6ES7 134-4LB02-0AB0 6ES7 134-4GB01-0AB0 6ES7 134-4GB52-0AB0

from backplane bus 3.3 V DC, max. 10 mA 0.6 W

Address space per module, max. Isochronous mode Isochronouos mode Analog inputs Number of analog inputs cable length, shielded, max. permissible input frequency for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Cycle time (all channels), max.

4 Byte No 2 200 m 35 V; 35 V continuous; 75 V for max. 1 ms (mark to space ratio 1:20)

4 Byte Yes 2 200 m 35 V; 35 V continuous; 75 V for max. 1 ms

4 Byte No 2 200 m

4 Byte Yes 2 200 m

40 mA Number of active channels per module x basic conversion time 0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression Number of active channels per module x basic conversion time 0.25 ms

Input ranges (rated values), voltages Voltage 1 to 5 V Input resistance (1 to 5 V) -10 V to +10 V Input resistance (-10 V to +10 V) -5 V to +5 V Input resistance (-5 V to +5 V) Input ranges (rated values), currents Current 0 to 20 mA Input resistance (0 to 20 mA) 4 to 20 mA Yes; on 50 ohms Yes Yes 106 Yes Yes Yes Yes Yes Yes Yes 800 k Yes 800 k Yes 800 k

5/48

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 14 Bit; +/-10 V: 13 bits + sign, +/-5 V: 13 bits + sign; 1 to 5 V: 13 bits 16.7 / 20 ms 60 / 50 Hz 65 ms; 55 / 65 ms 60 / 50 Hz / no 0.04 ms; Without noise suppression 17/20 ms per channel with error Yes; in 4 stages: 1x, 4x, 16x, 32x cycle time Yes; 1x Yes; 4x Yes; 16 x Yes 16 Bit; 0 to 5 V: 15 bits, +/-10 V: 16 bits, +/-5 V: 16 bits Yes 16.7 / 20 ms 60 / 50 Hz 65 ms; 55 / 65 ms 13 Bit; 4 to 20 mA: 13 bits 16 Bit integrating integrating 6ES7 134-4FB01-0AB0 6ES7 134-4LB02-0AB0 6ES7 134-4GB01-0AB0 6ES7 134-4GB52-0AB0

Integration time, parameterizable Integration time, ms Interference voltage suppression for interference frequency f1 in Hz Conversion time (per channel)

Smoothing of measured values parameterizable Level: none Level: weak Level: middle Level: strong Encoder Connection of signal encoders for voltage measurement for current measurement as 2-wire transducer Burden of 2-wire transmitter, max. Errors/accuracies Linearity error (relative to input area) Temperature error (relative to input areas) Crosstalk between the inputs, min. Repeat accuracy in settled status at 25 C (relative to input area) Operational limit in overall temperature range Voltage, relative to input area +/- 0,6 % +/- 0,1 %; 0.2% without interference frequency suppression +/- 0,6 % +/- 0,3 % +/- 0,01 % +/- 0,01 %/K -50 db +/- 0,05 % +/- 0,01 % +/- 0,003 %/K -100 db +/- 0,01 % +/- 0,01 % +/- 0,005 %/K -50 db +/- 0,05 % +/- 0,03 % +/- 0,01 %/K 50 db +/- 0,1 % 750 Yes Yes Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes Yes Yes Yes; 4 Yes Yes; 32

Current, relative to input area Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,4 % +/- 0,05 %; 0.1% without interference frequency suppression

Current, relative to input area Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 70 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. 90 db 90 db

+/- 0,4 %

+/- 0,2 %

70 db

100 db

Siemens IK PI 2009

5/49

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Parameter Remark Diagnosis: wire break Measurement type/range Interference frequency suppression Collective diagnostics Overflow/underflow Status information/ alarms/diagnostics Alarms Process alarm Diagnoses Diagnostic functions Wire break Yes Yes; Measuring range 1 to 5 V only Yes Yes Yes 500 VDC Yes; Measuring range 1 to 5 V only Yes Yes Yes 500 VDC Yes Yes Yes Yes 500 VDC Yes Yes; At 4 to 20mA Yes Yes Yes Yes Yes disable/enable disable/enable disable/enable deactivated / +/-5 V / 1 to 5 V / +/-10 V deactivated / +/-5 V / 1 to 5 V / +/-10 V deactivated / 4 to 20 mA 4 bytes 12 bytes, 4 bytes in compatibility mode 4 bytes At 4 to 20 mA 4.20 mA, 0 to 20 mA No Yes Yes 6ES7 134-4FB01-0AB0 6ES7 134-4LB02-0AB0 6ES7 134-4GB01-0AB0 6ES7 134-4GB52-0AB0

Group error Overflow/underflow Diagnostics indication LED Collective error SF (red) Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between the inputs (UCM) between inputs and MANA (UCM) between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Dimensions Module width, max. Weights Weight, approx.

No Yes Yes

No Yes Yes

No Yes No

No Yes Yes

140 V DC/100 V AC 2 V AC PP 75 V DC / 60 V AC 75V DC,60V AC

15 mm 81 mm 52 mm

15 mm 81 mm 52 mm 15 mm

15 mm 81 mm 52 mm

15 mm 81 mm 52 mm 15 mm

40 g

45 g

40 g

5/50

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) Short-circuit protection reverse polarity protection Voltage supply to the transducers present short-circuit proof Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module Address space per module, max. Isochronous mode Isochronouos mode Analog inputs Number of analog inputs cable length, shielded, max. permissible input frequency for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Cycle time (all channels), max. 40 mA Number of active channels per module x basic conversion time 50 mA 0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression 30 mA; limited electronically 40 ms; 33 to 40 ms 250 s 2 200 m 2 200 m 4 200 m 2 200 m 35 V; permanent 30 mA 250 s 2 200 m No No Yes Yes 4 Byte 4 Byte 8 Byte 4 Byte 4 Byte 30 mA 48 mA 10 mA 1.2 W 125 mA 10 mA 0.6 W 80 mA 10 mA 1.9 W 80 mA 10 mA 1.9 W Yes Yes Yes Yes; approx. 200 mA for module Yes Yes Yes Yes Yes 24 V; From power module 24 V 24 V; From power module 24 V 24 V Yes Yes 6ES7 1344GB11-0AB0 6ES7 1344MB02-0AB0 6ES7 1344GD00-0AB0 6ES7 1344FB52-0AB0 6ES7 1344GB62-0AB0

from backplane bus 3.3 V DC, max. 10 mA 0.6 W

Input ranges (rated values), voltages Voltage 1 to 5 V Input resistance (1 to 5 V) -10 V to +10 V Input resistance (-10 V to +10 V) -2.5 V to +2.5 V Input resistance (-2,5 V to +2,5 V) -5 V to +5 V Input resistance (-5 V to +5 V) Input ranges (rated values), currents Current 0 to 20 mA Input resistance (0 to 20 mA) -20 to +20 mA 4 to 20 mA Yes; 50 ohms Yes; 50 ohms Yes Yes Yes; on 25 ohms Yes Yes Yes Yes 106 Yes Yes Yes Yes 120 k Yes 120 k Yes 120 k Yes 120 k

Siemens IK PI 2009

5/51

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, parameterizable Integration time, ms 16.7 / 20 ms Interference voltage suppression 60 / 50 Hz for interference frequency f1 in Hz Conversion time (per channel) 65 ms; 55 / 65 ms 0.04 ms; Without noise suppression 17/20 ms per channel with error Yes; in 4 stages: 1x , 4x , 16x , 32x cycle time Yes; 1x Yes; 4x Yes; 16 x Yes Yes; in 4 stages Yes Yes 14 Bit; +/-20 mA: 14 bits, 4 to 20 mA: 13 bits 16 Bit; as required Yes 13 Bit; 4 to 20 mA: 13 bits Yes 16,67 / 20 60 / 50 Hz 16 Bit 16 Bit integrating Sigma Delta 6ES7 1344GB11-0AB0 6ES7 1344MB02-0AB0 6ES7 1344GD00-0AB0 6ES7 1344FB52-0AB0 6ES7 1344GB62-0AB0

Smoothing of measured values parameterizable

Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes

Level: none Level: weak Level: middle Level: strong Encoder supply Number of outputs Output current, rated value Short-circuit protection Encoder Connection of signal encoders for voltage measurement for current measurement as 2-wire transducer Burden of 2-wire transmitter, max. Errors/accuracies

Yes; 1x cycle time Yes; 4x cycle time Yes; 16x cycle time Yes

Yes Yes Yes Yes; 32x cycle time

Yes Yes Yes Yes; 32x cycle time 2 90 mA Yes

Yes No 750 750 +/- 0,03 % +/- 0,03 %/K -100 db +/- 0,01 % 750 +/- 0,01 % +/- 0,003 %/K -50 db +/- 0,05 % +/- 0,03 % +/- 0,01 %/K -50 db +/- 0,1 % +/- 0,03 % +/- 0,01 %/K -50 db +/- 0,1 %

Linearity error (relative to input area) +/- 0,01 % Temperature error (relative to input areas) Crosstalk between the inputs, min. Repeat accuracy in settled status at 25 C (relative to input area) Operational limit in overall temperature range Voltage, relative to input area Current, relative to input area +/- 0,6 % +/- 0,005 %/K -50 db +/- 0,05 %

+/- 0,3 % +/- 0,1 %; 0.2% without interference frequency suppression +/- 0,4 % +/- 0,3 %

Basic error limit (operational limit at 25 C) Voltage, relative to input area Current, relative to input area +/- 0,4 % +/- 0,05 %; 0.1% without interference frequency suppression +/- 0,3 % +/- 0,2 % +/- 0,2 %

5/52

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 70 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. Parameter Remark Diagnosis: wire break 4 bytes Disable/enable (only in measuring range 4 to 20 mA) deactivated / +/-20 mA / 4 to 20 mA disable/enable deactivated / +/-20 mA / 4 to 20 mA 12 bytes, 4 bytes in compatibility mode 7 bytes Yes At 4 to 20mA 90 db 70 db 6ES7 1344GB11-0AB0 6ES7 1344MB02-0AB0 6ES7 1344GD00-0AB0 6ES7 1344FB52-0AB0 6ES7 1344GB62-0AB0

100 db

Measurement type/range

Yes

Collective diagnostics Overflow/underflow Status information/ alarms/diagnostics Alarms Process alarm Diagnoses Diagnostic functions Diagnostic information readable Wire break Yes; Measuring range 4 to 20 mA only Yes Yes Yes 500 VDC Yes; Measuring range 4 to 20 mA only Yes Yes Yes Yes Yes

Yes Yes

5
Yes Yes Yes Yes Yes

Yes; can be read out Yes; Measuring range 1 to 5 V only Yes Yes Yes 500 VDC

Yes Yes Yes

Group error Overflow/underflow Diagnostics indication LED Collective error SF (red) Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Dimensions Module width, max. Weights Weight, approx.

Yes Yes Yes

Yes Yes Yes

No Yes No

No Yes Yes

No Yes No

No Yes Yes

No Yes Yes

75V DC, 60V AC

15 mm 81 mm 52 mm

15 mm 81 mm 52 mm 15 mm

15 mm 81 mm 52 mm

15 mm 81 mm 52 mm 15 mm

15 mm 81 mm 52 mm 15 mm 45 g

40 g

45 g

40 g

45 g

Siemens IK PI 2009

5/53

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Voltage supply to the transducers present short-circuit proof Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module Address space per module, max. Isochronous mode 4 Byte No 2 200 m 4 Byte No 2 200 m 9V 1.25 mA Number of active channels per module x basic conversion time Yes Number of active channels per module x basic conversion time Number of active channels per module x basic conversion time Yes 4 Byte No 2 50 m 10 V; permanent 2 50 m 20 V; +/-20 V, continuous 4 Byte 30 mA 30 mA 10 mA 0.6 W 30 mA 10 mA 0.6 W 30 mA 10 mA 0.6 W Yes Yes 24 V; From power module Yes 24 V; From power module Yes 24 V; From power module Yes 24 V; From power module Yes 6ES7 134-4JB50-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB01-0AB0

from backplane bus 3.3 V DC, max. 10 mA 0.6 W

Isochronouos mode Analog inputs Number of analog inputs cable length, shielded, max.

permissible input frequency for volt- 9 V age input (destruction limit), max. Constant measurement current for resistance-type transmitter, typ. Cycle time (all channels), max. 1.5 mA Number of active channels per module x basic conversion time

technical unit for temperature measurement, adjustable Input ranges (rated values), voltages Voltage -80 mV to +80 mV Input resistance (-80 to +80 mV) Input ranges (rated values), thermoelements thermocouple Type B Input resistance (Type B) Type C Input resistance (Type C) Type E Input resistance (Type E) Type J Input resistance (type J) Type K Input resistance (Type K) Type L Input resistance (Type L) Type N Input resistance (Type N) Type R Input resistance (Type R) Type S Input resistance (Type S) Type T Input resistance (Type T)

Yes Yes 1 M

Yes Yes 1 M

Yes Yes 1 M

Yes Yes 1 M Yes 1 M

Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M

Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M Yes 1 M

5/54

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Input ranges (rated values), resistors Impedance 0 to 150 Ohm Input resistance (0 to 150 Ohm) 0 to 300 Ohm Input resistance (0 to 300 Ohm) 0 to 600 Ohm Input resistance (0 to 600 Ohm) 0 to 3000 Ohm Input resistance (0 to 3000 Ohm) Input ranges (rated values), resistance thermometers Resistance thermometer Cu 10 Input resistance (Cu 10) Ni 100 Input resistance (Ni 100) Ni 1000 Input resistance (Ni 1000) Ni 120 Input resistance (Ni 120) Ni 200 Input resistance (Ni 200) Ni 500 Input resistance (Ni 500) Pt 100 Input resistance (Pt 100) Pt 1000 Input resistance (Pt 1000) Pt 200 Input resistance (Pt 200) Pt 500 Input resistance (Pt 500) Characteristic curve linearization programmable for thermoelements for thermoresistor Temperature compensation external temperature compensation with compensations socket internal temperature compensation Yes Yes; possible, one external compensating box per channel Yes; one external compensating box per channel Yes; possible with TM-E15S24-AT, TM-E15C24-AT Pt100, Ni100 Ptxxx, Nixxx Yes; for Pt100, Ni100 Yes; for Ptxxx, Nixxx Yes; Type B, E, J, K, L, N, R, S, T to IEC 584 Yes Type B, C, E, J, K, L, N, R, S, T to IEC 584 Yes; Standard/AirCon 2,000 k Yes; Standard/climate 2,000 k Yes Yes Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes 10 M Yes Yes 2,000 k Yes 2,000 k Yes 2,000 k Yes Yes 10 M Yes 10 M Yes 10 M Yes 10 M 6ES7 134-4JB50-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB01-0AB0

Siemens IK PI 2009

5/55

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 16 Bit; 150 Ohm: 14 bit; 300, 600 Ohm: 15 bit; Pt100, Ni100: 16 bit 16 Bit; for Pt100, Ni100, Ni120, Pt200, Ni200, Pt 500, Ni 500, Pt1000, Ni1000, Cu10: 15 bits + sign; for 150, 300, 600, 3000 ohms: 15 bits; for PTC: 1 bit 16.7 / 20 ms 60 / 50 Hz 16 Bit; 15 bit + sign 16 Bit integrating integrating (Sigma-Delta) integrating integrating 6ES7 134-4JB50-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB01-0AB0

Integration time, parameterizable Integration time, ms

Yes 16.7 / 20 ms

Yes 16.7 / 20 ms 60 / 50 Hz 65 ms; 55 / 65 ms (additional 20 ms on activated wire-break test) 16.7 / 20 ms 60 / 50 Hz 66 ms; 66 / 80 ms; additional conversion time for diagnostic wire break test Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes

Interference voltage suppression 60 / 50 Hz for interference frequency f1 in Hz Conversion time (per channel) 110 ms; 110 / 130 ms

Smoothing of measured values parameterizable Level: none Level: weak Level: middle Level: strong Encoder Connection of signal encoders for voltage measurement for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection Burden of 2-wire transmitter, max. Errors/accuracies Linearity error (relative to input area) +/- 0,01 % Temperature error (relative to input areas) Crosstalk between the inputs, min. Repeat accuracy in settled status at 25 C (relative to input area) +/- 0,005 %/K -50 db +/- 0,05 % +/- 0.01 % +/- 0,0009 %/K -50 db +/- 0.05 % +/- 0,01 % +/- 0,005 %/K -50 db +/- 0,05 % +/- 0.01 % +/- 0.005 %/K -50 db +/- 0.05 % Yes; Line resistances are also measured, jumpers to TR Yes; Line resistances are also measured, jumpers to TR Yes 750 Yes Yes Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 64x cycle time Yes Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes Yes; In four stages by means of digital filtering Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes

Yes; internal compensation of the line resistances Yes

5/56

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Operational limit in overall temperature range Voltage, relative to input area +/- 0,6 % +/- 0.1 %; +/-1.5 K for thermocouples, +/-7 K for thermocouples type C, +/-2.5 K with static thermal state (ambient temperature change < 0.3 K/min) 6ES7 134-4JB50-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB01-0AB0

Resistance-type thermometer, relative to input area

+/- 0,6 %

Resistance-type transmitter: +/-0.1%; Pt100, Pt200, Pt500, Pt1000 standard: +/-1.0 K; Pt100, Pt200, Pt500, Pt1000 climate: +/-0.25 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: +/-0.4 K; Cu10 +/-1.5 K

Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,4 % +/- 0.05 %; +/-1 K with thermocouples, +/-5 K with thermocouples type C, +/-1.5 K with static thermal state (ambient temperature change < 0.3 K/min)

Resistance-type thermometer, relative to input area

+/- 0,4 %

Resistance-type transmitter: +/-0.05%; Pt100, Pt200, Pt500, Pt1000 standard: +/-0.6 K; Pt100, Pt200, Pt500, Pt1000 climate: +/-0.13 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: +/-0.2 K; Cu10 +/-1 K

Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 70 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. Parameter Remark Measurement type/range 4 bytes deactivated/150 ohms/; 300 ohms/600 ohms/; Pt100 climatic/ Pt100 standard; Ni100 standard / Ni100 climatic 7 bytes deactivated/ 150 ohms/ 300 ohms/ 600 ohms/ Pt100/ Pt200/ Pt500/ Pt1000 each standard or climate range/ Ni100/ Ni120/ Ni200/ Ni500/ Ni1000 each standard or climate range/ Cu10 each standard or climate range / PTC 4 bytes Deactivated/ +/- 80 mV/; +/- 250 mV / +/- 500 mV /; +/- 1 V /; TC-EL type T (Cu-CuNi)/ TC-EL type K (NiCr-Ni)/ TC-EL type B; (PtRh-PtRh)/; TC-EL type N; (NiCrSi-NiSi)/; TC-EL type E; (NiCr-CuNi)/; TC-EL type R (PtRh-Pt)/ TC-EL type S (PtRh-Pt)/ TC-EL Type J 4 bytes Deactivated/ +/- 80 mV/; TC-EL type T (Cu-CuNi)/ TC-EL type K (NiCr-Ni)/ TC-EL type B; (PtRh-PtRh)/; TC-EL type c (Wer-Wer); TC-EL type N; (NiCrSi-NiSi)/ , TC-EL type E; (NiCr-CuNi)/; TC-EL type R (PtRh-Pt)/ TC-EL type S (PtRh-Pt)/ TC-EL type J (Fe-Cu-Ni)/ TC 90 db 70 db 70 db 70 db

90 db

90 db

90 db

Collective diagnostics Slot comparison point 1 to 8 Overflow/underflow Comparison point Comparison point number Unit disable/enable

Disable/enable disable/enable disable/enable disable/enable none / RTD none / 1/2/3/4/5/6/7/8 Celsius Celsius / Fahrenheit disable/enable none / yes, internal

Siemens IK PI 2009

5/57

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Diagnoses Diagnostic functions Wire break Yes; can be read out Yes; A wire break is only detected on constand current lines Yes Yes Yes 500 VDC Yes Yes; can be read out Yes; A break in the wire is only detected on thermocouples Yes Yes Yes 500 VDC Yes; only thermocouples 6ES7 134-4JB50-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB01-0AB0

Group error Overflow/underflow Diagnostics indication LED Collective error SF (red) Isolation Isolation checked with Isolation Isolation, analog inputs between the channels

Yes Yes Yes 500 VDC

Yes Yes Yes 500 VDC

No Yes Yes

No Yes Yes

No Yes Yes

No Yes Yes

between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between inputs and MANA (UCM) between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, max. Address area Address space per module Address space per module, max. Isochronous mode Isochronouos mode Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Voltage output, short-circuit current, max..

2 V AC PP 75 V DC / 60 V AC 75 V DC / 60 V AC 75 V DC / 60 V AC

140 V DC/100 V AC 75 V DC / 60 V AC

15 mm 81 mm 52 mm 40 g 6ES7 135-4FB01-0AB0

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g 6ES7 135-4FB52-0AB0

15 mm 81 mm 52 mm 40 g 6ES7 135-4LB02-0AB0

24 V; From power module Yes 130 mA

24 V; From power module Yes 100 mA 10 mA 2W

24 V Yes 80 mA 10 mA 1.2 W

from backplane bus 3.3 V DC, max. 10 mA 2W

4 Byte

4 Byte Yes

4 Byte Yes 2 200 m; 100m if Twa < 2ms Yes 25 mA

2 200 m Yes 25 mA

2 200 m; Max. 20m for Twa=0.1ms Yes 25 mA

5/58

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Current output, no-load voltage, max. Cycle time (all channels) max. Output ranges, voltage 1 to 5 V -10 to +10 V Output ranges, current -20 to +20 mA 4 to 20 mA Connection of actuators for voltage output 2-conductor connection for voltage output 4-conductor connection for current output 2-conductor connection for current output 4-conductor connection Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Destruction limits against externally applied voltages and currents Voltages at the outputs towards MANA Current, max. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 14 Bit; 1 to 5 V: 12 bits, +/-10 V: 13 bits + sign 16 Bit; 1 to 5 V: 14 bit, +/-10V: 15 bit + VZ, +/-5 V: 14 bit + sign 0.05 ms 0.05 ms 0.05 ms 16 Bit; 15 bit + sign 15 V; max. 15 V continuous; 75 V for max. 1 s (mark to space ratio 1:20) 50 mA; DC 15 V; Max. 15 V for max. 5 hours, 75 V for max. 1 s 30 mA; DC 15 V; as required 1 k 1 F 1 k 1 F; 0.1F for Twa=0.1ms 1 k 0.5 F Yes; Without compensation of the line resistances Yes Yes; Without compensation of the line resistances Yes Yes Yes Yes Yes Yes Yes; +/-5V as well Yes; -5 to +5 V also implemented Yes 1.5 ms 0.25 ms 0.5 ms; at max. 0.5 F 6ES7 135-4FB01-0AB0 6ES7 135-4FB52-0AB0 6ES7 135-4LB02-0AB0

Settling time for resistive load for capacitive load for inductive load Ex(i) characteristics Max. values of output circuits (per channel) Uo (output no-load voltage), max. Errors/accuracies Output ripple (based on output range, bandwidth 0 to 50 kHz) Linearity error (relative to output area) Temperature error (relative to output area) Crosstalk between the outputs, min. Repeat accuracy in settled status at 25 C (relative to output area) +/- 0,05 % +/- 0,02 % +/- 0,02 % +/- 0,01 %/K +/- 0,02 % +/- 0,03 % +/- 0,01 %/K 60 dB +/- 0,03 % 60 dB +/- 0,01 % +/- 0,02 % +/- 0,01 % 0.1 ms 0.5 ms 0.5 ms 0.2 ms 0.5 ms; at max. 0.5F 0.5 ms

Siemens IK PI 2009

5/59

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Operational limit in overall temperature range Voltage, relative to output area Current, relative to output area Basic error limit (operational limit at 25 C) Voltage, relative to output area Current, relative to output area Parameter Remark Output type/range Diagnosis: wire break Diagnosis: short circuit Interference frequency suppression Collective diagnostics Disable/enable Output current and de-energized/ substitute a value/keep last value Disable/enable Output current and de-energized/ substitute a value/keep last value Disable/enable Disable/enable Disable/enable no Disable/enable Output current and de-energized/ substitute a value/keep last value 7 bytes deactivated / 1 to 5 V / +/ -10 V 7 Deactivated / 1 to 5 V / +/-10V / +/-5 V 7 bytes deactivated / 1 to 5 V / +/ -10 V / +/- 5 V +/- 0,2 % +/- 0,01 % +/- 0,05 % +/- 0,4 % +/- 0,2 % +/- 0,1 % 6ES7 135-4FB01-0AB0 6ES7 135-4FB52-0AB0 6ES7 135-4LB02-0AB0

Behavior on CPU/Master STOP Status information/ alarms/diagnostics Substitute values connectable Diagnoses Diagnostic functions Diagnostic information readable Wire break Short circuit Group error Diagnostics indication LED Collective error SF (red) Isolation Isolation checked with Isolation Isolation, analog outputs Galvanic isolation, analog outputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Weights Weight, approx.

Yes; 0 to 65535 (range of values must be within the rated range)

Yes; 0 to 65535 (range of values must be within the rated range) Yes Yes No

Yes

Yes Yes Yes Yes 500 VDC

Yes Yes Yes

Yes Yes Yes

No Yes Yes

No Yes Yes

No Yes Yes

75 V DC / 60 V AC

75 V DC / 60 V AC

75 V DC / 60 V AC

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

15 mm 81 mm 52 mm 40 g

5/60

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, max. Address area Address space per module Address space per module, max. Isochronous mode Isochronouos mode Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Cycle time (all channels) max. Output ranges, voltage 1 to 5 V -10 to +10 V Output ranges, current -20 to +20 mA 4 to 20 mA Connection of actuators for voltage output 2-conductor connection for voltage output 4-conductor connection for current output 2-conductor connection for current output 4-conductor connection Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Destruction limits against externally applied voltages and currents Voltages at the outputs towards MANA Current, max. 15 V; max. 15 V continuous; 75 V for max. 1 s (mark to space ratio 1:20) 50 mA; DC 50 mA 500 1 mH 500 1 mH Yes No Yes No Yes Yes Yes Yes 18 V 1.5 ms 18 V 0.5 ms 2 200 m 2 200 m; 100m if Twa < 2ms Yes 4 Byte 4 Byte 150 mA 80 mA 10 mA 1.2 W 24 V; From power module Yes 24 V Yes 6ES7 135-4GB01-0AB0 6ES7 135-4MB02-0AB0

from backplane bus 3.3 V DC, max. 10 mA 2W

Siemens IK PI 2009

5/61

Siemens AG 2008

ET 200S

SIMATIC ET 200 distributed I/Os

Analog electronic modules

Technical specifications (continued)


Order No. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Settling time for resistive load for capacitive load for inductive load Ex(i) characteristics Max. values of output circuits (per channel) Uo (output no-load voltage), max. Errors/accuracies Output ripple (based on output range, bandwidth 0 to 50 kHz) +/- 0,02 % +/- 0,02 % +/- 0,01 %/K +/- 0,02 % +/- 0,01 % +/- 0,003 %/K 60 dB +/- 0,05 % +/- 0,01 % 18 V 0.1 ms 0.5 ms 0.5 ms 0.3 ms 1 ms 0.5 ms 14 Bit; 4 to 20 mA: 13 bits, +/-20 mA: 14 bits 16 Bit 6ES7 135-4GB01-0AB0 6ES7 135-4MB02-0AB0

Linearity error (relative to output area) Temperature error (relative to output area) Crosstalk between the outputs, min. Repeat accuracy in settled status at 25 C (relative to output area) Operational limit in overall temperature range Voltage, relative to output area Current, relative to output area Basic error limit (operational limit at 25 C) Voltage, relative to output area Current, relative to output area Parameter Remark Output type/range Diagnosis: wire break Diagnosis: short circuit Interference frequency suppression Collective diagnostics Behavior on CPU/Master STOP Status information/ alarms/diagnostics Substitute values connectable Diagnoses Diagnostic functions Diagnostic information readable Wire break Short circuit Group error Diagnostics indication LED Collective error SF (red)

+/- 0,5 %

+/- 0,1 %

+/- 0,3 % 7 bytes deactivated / +/-20 mA / 4 to 20 mA Disable/enable

+/- 0,05 % 7 bytes deactivated / +/-20 mA / 4 to 20 mA Disable/enable disable / enable

Disable/enable Output current and de-energized/substitute a value/ keep last value

Disable/enable Output current and de-energized/substitute a value/ keep last value

Yes; 0 to 65535 (range of values must be within the rated range)

Yes

Yes Yes Yes Yes Yes Yes Yes

5/62

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S

Analog electronic modules

Technical specifications (continued)


Order No. Isolation Isolation checked with Isolation Isolation, analog outputs Galvanic isolation, analog outputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Permissible potential difference between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Weights Weight, approx. 40 g Order No. Accessories for labeling Label sheets DIN A4 (10 pieces) 6ES7 134-4FB52-0AB0 6ES7 134-4FB01-0AB0 6ES7 134-4LB02-0AB0 6ES7 134-4GB01-0AB0 6ES7 134-4GB52-0AB0 6ES7 134-4GB62-0AB0 6ES7 134-4GB11-0AB0 6ES7 134-4MB02-0AB0 6ES7 134-4JB50-0AB0 6ES7 134-4JB00-0AB0 6ES7 134-4NB51-0AB0 6ES7 134-4NB01-0AB0 6ES7 134-4GD00-0AB0 Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige Shield connection element Ordering unit 5 items For plugging into TM-E and TM-P Shield clamps Ordering unit 5 items For 3 10 mm busbars Grounding terminal Ordering unit 1 item 6ES7 135-4FB01-0AB0 6ES7 135-4FB52-0AB0 6ES7 135-4LB02-0AB0 6ES7 135-4GB01-0AB0 6ES7 135-4GB52-0AB0 6ES7 135-4MB02-0AB0 For cable cross-sections up to 25 mm2 3 10 mm busbars Ordering unit 1 item 8WA2 842 8WA2 868 6ES7 193-4GB00-0AA0 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 6ES7 193-4GA00-0AA0 40 g Order No. 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm 75 V DC / 60 V AC 75 V DC / 60 V AC No Yes Yes Yes No Yes Yes 500 VDC 6ES7 135-4GB01-0AB0 6ES7 135-4MB02-0AB0

Ordering data
Analog input modules Ordering unit 1 item 2 AI U High Speed 2 AI U Standard 2 AI U High Feature 2 AI I Standard 2-wire 2 AI I High Speed 2-wire 2 AI High Speed 4-wire 2 AI I Standard 4-wire 2 AI I High Feature 2-wire/4-wire (15 bit + sign) 2 AI RTD Standard 2 AI TC Standard 2 AI RTD High Feature 2 AI TC High Feature 4 AI Standard 2-wire Analog output modules Ordering unit 1 item 2 AO U Standard 2 AO U High Speed 2 AO U High Feature 2 AO I Standard 2 AO I High Speed 2 AO I High Feature

Accessories for system-integrated shield connection

Siemens IK PI 2009

5/63

Siemens AG 2008

ET 200S
Overview

SIMATIC ET 200 distributed I/Os

SIPLUS analog electronic modules (extended temperature range)

Analog electronic module SIPLUS 2 AI I Standard 2-wire Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 134-4GB01-2AB0 6ES7 134-4GB01-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Analog electronic module SIPLUS 2 AI I High Speed 2-wire Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 134-4GB52-2AB0 6ES7 134-4GB52-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Analog electronic module SIPLUS 2 AI I Standard 4-wire Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 134-4GB11-2AB0 6ES7 134-4GB11-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Analog electronic module SIPLUS 4 AI RTD Standard 4-wire Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 134-4JB50-2AB0 6ES7 134-4JB50-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

Analog inputs and outputs for the ET 200S Can be plugged onto TM-E terminal modules with automatic coding. High feature variants with enhanced performance, precision and resolution Hot swapping of modules possible Note: Consult the configuring guide for selection of the appropriate TM-E terminal modules.

Technical data

Technical data

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Ordering data
SIPLUS analog electronic module, analog input (extended temperature range and medial exposure) 2 AI I Standard 2-wire 2 AI I Standard 4-wire 2 AI High Speed 2-wire 2 AI RTD standard Accessories for labeling

Order No.

6AG1 134-4GB01-2AB0 6AG1 134-4GB11-2AB0 6AG1 134-4GB52-2AB0 6AG1 134-4JB50-2AB0 see Analog electronic modules ordering data

5/64

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Fail-safe modules


Overview

Overview
Totally Integrated Automation (TIA) Safety technology (Safety Integrated) is a component of Totally Integrated Automation resulting in the total integration of safety and standard automation (SIMATIC S7). Whereas today, standard automation (conventional PLCs) and safety automation (electromechanics) are still separate, these two worlds are growing closer together to form one uniform, integrated overall system. Siemens can therefore present itself as a complete supplier for automation engineering for which safety technology is part of the standard automation and uniformity exists throughout the complete system.

The fail-safe SIMATIC S7 CPUs, plus the fail-safe signal modules of SIMATIC ET 200S / ET200 / 200pro/ ET200eco and ET200M have been specially developed for distributed applications in manufacturing systems. Thanks to the discrete structure of the F I/Os, safety technology is only applied where actually required. The new system replaces conventional electromechanical components, such as: Freely programmable safe linking of sensors to actuators; Selective safe shutdown of actuators; Hybrid configurations of F modules (F stands for fail-safe) and standard modules in a station; Single-bus concept, F signals and standard signals are transferred over one bus medium (PROFIBUS DP, PROFINET).

Siemens IK PI 2009

5/65

Siemens AG 2008

ET 200S Fail-safe modules


PM-E F PROFIsafe F power module

SIMATIC ET 200 distributed I/Os

Overview

Ordering data
Power module PM-E F pm PROFIsafe, 24 V DC For safe shutdown of digital output modules Power module PM-E F pp PROFIsafe, 24 V DC For safe shutdown of digital output modules Accessories IM 151-1 HIGH FEATURE interface module For ET 200S; data transmission rate up to 12 Mbit/s; data volumes 244 bytes each for I/O, up to 63 modules can be connected; connection of PROFIsafe modules, isochronous mode; bus connection via 9-pin Sub-D incl. terminating module

Order No. 6ES7 138-4CF02-0AB0

6ES7 138-4CF41-0AB0

6ES7151-1BA02-0AB0

Fail-safe PM-E F PROFIsafe power modules for safety shutdown of standard digital output modules. Up to 2 fail-safe digital outputs onboard (source/sink outputs, up to 2A, up to SIL3/Cat. 4) The standard digital output modules can be shut down up to Cat.3 (EN 954) and SIL 2 (IEC61508) up to 10 A. The following modules can be used down-circuit of the power modules. - 2 DO / 0.5 A ST 6ES7 132-4BB01-0AA0 - 2 DO / 2 A ST 6ES7 132-4BB31-0AA0 - 2 DO / 0.5 A HF 6ES7 132-4BB01-0AB0 - 2 DO / 2 A HF 6ES7 132-4BB31-0AB0 - 4 DO / 0.5 A ST 6ES7 132-4BD01-0AA0 - 4 DO / 2 A ST 6ES7 132-4BD31-0AA0 The modules support PROFIsafe, both in PROFIBUS, and in PROFINET configurations. They can be used with all fail-safe SIMATIC S7-CPUs.

IM 151-3 PN HF interface module For ET 200S; data transmission rate up to 100 Mbit/s; max. 63 I/O modules up to 2 m wide can be connected; 2 x bus connection via RJ45 connector, incl. terminating module IM 151-3 PN FO interface module For ET 200S; 2 PROFINET FO interfaces, integrated 2-port switch, max. 63 I/O modules up to 2 m wide can be connected, incl. terminating module Terminal modules for power modules TM-P30S44-A0 Ordering unit 1 unit 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals for PM-E F PROFIsafe TM-P30C44-A0 Ordering unit 1 unit 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals for PM-E F PROFIsafe Distributed Safety V5.4 programming tool Task: Software for configuring failsafe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade From V5.x to V5.3; Floating license for 1 user SIMATIC Manual Collection Electronic manuals on DVD, five languages: S7-200/300/400, C7, LOGO!, SIMATIC DP, PC, PG, STEP 7, engineering software, runtime software, PCS 7, SIMATIC HMI, SIMATIC NET SIMATIC Manual Collection update service for 1 year

6ES7 151-3BA23-0AB0

6ES7 151-3BB22-0AB0

6ES7 193-4CK20-0AA0

6ES7 193-4CK30-0AA0

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

5/66

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Fail-safe modules


F electronic modules

Overview
Digital inputs/outputs for the fail-safe SIMATIC S7 systems Fail-safe digital input module For fail-safe reading of sensor information (1 or 2 channels) Provides integral discrepancy evaluation for 2-out-of-2 signals 2 internal sensor supplies (incl. test function) onboard Fail-safe digital output module Fail-safe 2-channel activation (sink/source output) by actuators Actuators can be driven by up to 2 A All modules are certified up to Cat. 4 (EN954-1) and up to SIL 3 (IEC 61508). The modules support PROFIsafe, both in PROFIBUS, and in PROFINET configurations. They can be used with all fail-safe SIMATIC S7 CPUs.

Technical specifications
Order No. Supply voltages Rated value DC 24 V permissible range, upper limit (DC) Reverse polarity protection Current consumption Power loss, typ. Address area Occupied address area Outputs Inputs Digital inputs Number of digital inputs Number of simultanneously controllable inputs Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - programmable - at " to "1", min. - at "0" to "1", max. - at "1" to "0", min. - at "1" to "0", max. Yes 0.3 ms 17 ms 0.3 ms 17 ms 3.7 mA to IEC 61508 Dimensions Dimensions Width Height Depth Weights Weight, approx. 78 g 30 mm 81 mm 52 mm 24 V -30 to +5 V 15 to 30 V 200 m 200 m Yes 8; 8 single-channel, 4 two-channel 8 4 Byte 6 Byte 4W Yes 28.8 V No Encoder Connectable encoders 2-wire BEROS Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Standards, approvals, certificates Highest safety class achievable in safety mode to EN 954 Cat. 3 (single-channel), Cat. 4 (two-channel) SIL 2 (single-channel), SIL 3 (two-channel) No Yes No Yes Yes Yes No permissible range, lower limit (DC) 20.4 V 6ES7 138-4FA03-0AB0 Order No. Encoder supply Number of outputs Output voltage Output current, rated value Output current, permissible range Short-circuit protection 2 min. L+ (-1.5 V) 300 mA 0 to 300 mA Yes; electronic (response threshold 0.7 A to 1.8 A) 6ES7 138-4FA03-0AB0

Siemens IK PI 2009

5/67

Siemens AG 2008

ET 200S Fail-safe modules


F electronic modules

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, typ. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Limitation of inductive shutdown voltage to 4 200 m 200 m typ. (L+) -47 V 10 W No L+ (-2,0 V), current sourcing switch: L+ (-1,5 V), voltage drop on current sinking switch: max. 0.5 V 2A 20 mA 2.4 A typ. 100 mA 24 V No 6ES7 138-4FB02-0AB0 Order No. Status information/ alarms/diagnostics Diagnoses Diagnostic functions Wire break Short circuit Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Isolation Isolation, digital outputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Standards, approvals, certificates Highest safety class achievable in safety mode to EN 954 to IEC 61508 Dimensions Dimensions Width Height Depth Weights Weight, approx. 85 g 30 mm 81 mm 52 mm Cat. 4 SIL 3 No Yes No Yes Yes 3.5 W Yes Yes Yes 6ES7 138-4FB02-0AB0

from backplane bus 3.3 V DC, max. 28 mA

Short-circuit protection of the output Yes; Electronic

Lamp load, max. Controlling a digital input Output voltage for signal "1", min.

Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max.

for signal "0" residual current, max. 0.5 mA; Current sourcing switch: max. 0.5 mA; current sinking switch: max. 4 mA Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 55 C, max. up to 60 C, max. Load impedance range lower limit upper limit 12 1 k 6A 5A 4 mA 4 mA 30 Hz 0.1 Hz 10 Hz No No

5/68

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Fail-safe modules


F electronic modules

Ordering data
Electronic module 4/8 F-DI PROFIsafe 24 V DC 30 mm construction width, up to Category 4 (EN954-1) Electronic module 4 F-DO PROFIsafe 24 V DC/2A 30 mm construction width, up to Category 4 (EN954-1) Electronic module 4 F-DI / 3 F-DO PROFIsafe 24 V DC/2A 30 mm construction width, up to Category 3 (EN954-1) / SIL 2 (IEC 62061) Accessories Terminal modules for electronic modules IM 151-1 High Feature interface module for ET 200S; data transmission rate up to 12 Mbit/s; max. 63 modules can be connected, with isochronous mode, bus connection via 9-pin Sub-D connector incl. terminating module IM 151-3 PN HF interface module for ET 200S; data transmission rate up to 100 Mbit/s; max. 63 I/O modules up to 2 m wide can be connected; 2 x bus connection via RJ45 connector, incl. terminating module IM 151-3 PN FO interface module for ET 200S; 2 PROFINET FO interfaces, integrated 2-port switch, max. 63 I/O modules up to 2 m wide can be connected, incl. terminating module

Order No. 6ES7 138-4FA03-0AB0 Accessories (continued) Distributed Safety V5.4 programming tool 6ES7 138-4FB02-0AB0 Task: Software for configuring fail-safe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade See F terminal modules 6ES7 151-1BA02-0AB0 From V5.x to V5.3; Floating license for 1 user SIMATIC Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No.

6ES7 138-4FC00-0AB0

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

6ES7 998-8XC01-8YE0

5
6ES7 998-8XC01-8YE2

6ES7 151-3BA23-0AB0

6ES7 151-3BB22-0AB0

Siemens IK PI 2009

5/69

Siemens AG 2008

ET 200S Fail-safe modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS fail-safe electronics modules (extended temperature range)

Electronics module 4/8 F-DI, PROFIsafe 24 V DC Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 138-4FA03-2AB0 6ES7 138-4FA03-0AB0 -25 +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. Electronics module 4 F-DO, PROFIsafe 24 V DC/2 A Order No. Order No. based on 6AG1 138-4FB02-2AB0 6ES7 138-4FB02-0AB0 -25 +60 C; condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical specifications

Digital inputs/outputs for the fail-safe SIMATIC S7 systems

Ambient temperature range Environmental conditions

Fail-safe digital input module For fail-safe reading of sensor information (1 or 2 channels) Provides integral discrepancy evaluation for 2-out-of-2 signals 2 internal sensor supplies (incl. test function) onboard Fail-safe digital output module Fail-safe 2-channel activation (sink/source output) by actuators Actuators can be driven by up to 2 A All modules are certified up to Cat. 4 (EN 954-1) and up to SIL 3 (IEC 61508). The modules support PROFIsafe, both in PROFIBUS and in PROFINET configurations. They can be used with all fail-safe SIMATIC S7 CPUs.

Technical specifications

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Ordering data
F electronics modules SIPLUS (extended temperature range and medial exposure) 4/8 F-DI PROFIsafe 24 V DC electronics module 30 mm construction width, up to Category 4 (EN 954-1) Electronics module 4 F-DO PROFIsafe 24 V DC/2 A 30 mm construction width, up to Category 4 (EN 954-1) Accessories

Order No.

6AG1 138-4FA03-2AB0

6AG1 138-4FB02-2AB0

see F electronics modules ordering data

5/70

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Fail-safe modules


F electronic modules RELAY

Overview
The digital electronics module 1 F-RO 24 V DC/5A 24 to 230 V AC/5A has the following characteristics 1 relay output (2 NO contacts) Output current 5 A. Rated load voltage 24 V DC and 24 to 230 V AC The control circuit of the two safety relays must be routed from the outside to the respective terminals. The attainable safety integrity level is SIL3 (IEC61508), when the control of the F-RO module is implemented via a fail-safe output (e.g. EM 4F-DO 24 V DC/2A PROFIsafe).

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module with packing without packing Digital inputs Cable length Cable length unshielded, max. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. 1 200 m 200 m 10 m; control cable 2 Bit 1 Byte 100 mA; from control voltage 24 V; Supply via fail-safe output, e.g. of an F-DO 6ES7 138-4FR00-0AA0 Order No. Relay outputs Switching capacity of the contacts Thermal continuous current, max. Status information/ alarms/diagnostics Diagnostics indication LED Status indicator digital output (green) Isolation Isolation, digital outputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Standards, approvals, certificates Highest safety class achievable in safety mode to EN 954 to IEC 61508 Dimensions Dimensions Width Height Depth 5A Weights Weight, approx. 90 g 30 mm 81 mm 52 mm to Cat. 4 up to SIL 3 Yes Yes Yes; between channels and control voltage Yes 5A 6ES7 138-4FR00-0AA0

from backplane bus 3.3 V DC, max. 10 mA 2.1 W

Short-circuit protection of the output No; 6 A external fuse of duty category gL/gG Controlling a digital input Output current for signal "1" rated value Switching frequency with resistive load, max. with inductive load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 55 C, max. - up to 60 C, max. 8A 6 A; at 50C 5 A; up to max. 24.8 V 6A 2 Hz 0.1 Hz for signal "1" minimum load current 5 mA Yes

Siemens IK PI 2009

5/71

Siemens AG 2008

ET 200S Fail-safe modules


F electronic modules RELAY

SIMATIC ET 200 distributed I/Os

Ordering data
Electronics module 1 F-RO 24 V DC/5A 24 to 230 V AC/5A Accessories Terminal modules for electronic modules IM 151-1 High Feature interface module For ET 200S; transmission rate up to 12 Mbit/s; max. 63 modules can be connected, with isochronous mode, bus connection via 9pin Sub-D connector incl. terminating module IM 151-3 PN HF interface module For ET 200S; transfer rate up to 100 Mbit/s; max. 63 I/O modules up to 2 m wide can be connected; 2 x bus connection via RJ45 connector, incl. terminating module

Order No. 6ES7 138-4FR00-0AA0 Accessories (continued) Distributed Safety V5.4 programming tool See F terminal modules 6ES7 151-1BA02-0AB0 Task: Configuration software for configuring of failsafe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade 6ES7 151-3BA23-0AB0 From V5.x to V5.3; Floating license for 1 user SIMATIC Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No.

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

6ES7 998-8XC01-8YE0

IM 151-3 PN FO interface module For ET 200S; 2 PROFINET FO interfaces, integrated 2-port switch, max. 63 I/O modules up to 2 m wide can be connected, incl. terminating module

6ES7 151-3BB22-0AB0

6ES7 998-8XC01-8YE2

5/72

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Fail-safe modules


F terminal modules

Overview

Ordering data
TM-P15S23-A1 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-P15C23-A1 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-P15S23-A0 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals TM-P15C23-A0

Order No.

Terminal modules for power modules 6ES7 193-4CC20-0AA0

6ES7 193-4CC30-0AA0

6ES7 193-4CD20-0AA0

6ES7 193-4CD30-0AA0

Mechanical modules as receptacles for the electronic modules For setting up permanent wiring through self-configuring voltage buses Keyed connection technology to ensure an enhanced vibration resistance of up to 5 g Different versions to accommodate power modules and electronic modules Replaceable terminal box (even within the station network) Automatic coding of the electronic modules Self-shielding of the backplane bus for high data security Color coding facility for the terminals and for identifying the slot numbers Alternatively available with screw-type or spring-loaded terminals For up to 60 % faster process wiring also with FastConnect connection method (av. soon)

Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals TM-P15S22-01 Ordering unit 1 item 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-P15C22-01 Ordering unit 1 item 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-P30S44-A0 Ordering unit 1 item 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals for PM-E F PROFIsafe TM-P30C44-A0 Ordering unit 1 item 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals for PM-E F PROFIsafe 6ES7 193-4CK30-0AA0 6ES7 193-4CK20-0AA0 6ES7 193-4CE10-0AA0 6ES7 193-4CE00-0AA0

Siemens IK PI 2009

5/73

Siemens AG 2008

ET 200S Fail-safe modules


F terminal modules

SIMATIC ET 200 distributed I/Os

Ordering data
TM-E30S44-01 Ordering unit 1 item 4 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E30C44-01 Ordering unit 1 item 4 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, springloaded terminals TM-E30S46-A1 Ordering unit 1 item 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E30C46-A1

Order No. Accessories Color coding plates Ordering unit 200 items for TM-P, TM-E white yellow 6ES7 193-4CG30-0AA0 yellow/green red blue brown 6ES7 193-4CF40-0AA0 turquoise Ordering unit 1200 items, for SIMATIC ET 200S terminal modules, includes 60 strips with 20 items each 6ES7 193-4CF50-0AA0 yellow yellow/green Grounding terminal Ordering unit 1 item For cable cross-sections up to 25 mm2 3 10 mm busbars Ordering unit 1 item Labels, inscribed Ordering unit 1 set 200 units for slot numbering (1 to 20) 10 200 units for slot numbering (1 to 40) 5 200 units for slot numbering (1 to 64) 1 , (1 to 68) 2 Labels, blank 200 units for slot numbering

Order No.

Terminal modules for electronic modules 6ES7 193-4CG20-0AA0

6ES7 193-4LA20-0AA0 6ES7 193-4LB20-0AA0 6ES7 193-4LC20-0AA0 6ES7 193-4LD20-0AA0 6ES7 193-4LF20-0AA0 6ES7 193-4LG20-0AA0 6ES7 193-4LH20-0AA0

6ES7 193-4LB10-0AA0 6ES7 193-4LC10-0AA0 8WA2 868

Ordering unit 1 item 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals

8WA2 842

8WA8 861-0AB 8WA8 861-0AC 8WA8 861-0DA

8WA8 848-2AY

5/74

Siemens IK PI 2009

Siemens AG 2008

ET 200S IQ-Sense Modules and Sensors


4 IQ-Sense and 8 IQ-Sense sensor modules

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, typ. Digital inputs Number of digital inputs Cable length cable length, shielded, max. Cable length unshielded, max. Analog inputs 50 m 50 m 3.24 ms 4 300 mA 0.85 W 24 V; From power module Yes 6ES7 138-4GA00-0AB0

The 4 IQ-Sense sensor module is an intelligent 4-channel electronic module for the ET 200S distributed I/O in PROFIBUS DP networking systems. It is used to connect photoelectric sensors using IQ-Sense technology. The 8IQ-Sense sensor module is an intelligent 8-channel I/O module for SIMATIC S7-300 and ET 200M and is used to connect photoelectric and ultrasonic sensors using IQ-Sense technology. It is possible to combine different types of sensors on one module. Standard function blocks are available for simplified handling of a SIMATIC S7. Conventional sensors cannot be operated on these modules. The main applications of the IQ-Sense system are found in installations and machines: With high availability demands With a high probability of interaction between sensors With the need for high flexibility and dynamic changing of sensor parameters.

Cycle time (all channels), max. Encoder Connectable encoders Description Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostics indication LED Collective error SF (red) Status indicator sensor channel (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx.

Photoelectric proximity switches with IQ-SENSE

Yes; Diagnostic information readable Yes Yes

500 VDC

No Yes

75 VDC / 60 VAC

15 mm 81 mm 52 mm 35 g

Siemens IK PI 2009

5/75

Siemens AG 2008

ET 200S IQ-Sense Modules and Sensors


4 IQ-Sense and 8 IQ-Sense sensor modules

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Connection point required front connectors Digital inputs Number of digital inputs Cable length Cable length unshielded, max. Encoder Connectable encoders Description photoelectronic proximity switches and ultrasonic sensors with IQ-Sense, cycle time 2.88 to 6 ms 50 m 8 20-pin 1A 150 mA; typically 24 V 6ES7 338-7XF00-0AB0

Ordering data
Sensor module 4IQ-Sense Sensor module 8 x IQ-Sense Sensors for connecting to the 4 IQ-Sense sensor module Diffuse sensor, type C40 IQ-Sense Diffuse sensor, type K80 IQ-Sense Reflex sensor, type C40 IQ-Sense Reflex sensor, type K80 IQ-Sense Diffuse sensor with background suppression, type K80 IQ-Sense Ultrasonic sensors M18 IQ-Sense Sensing range 5 to 30 cm Ultrasonic sensors M18 IQ-Sense Sensing range 15 to 100 cm

Order No. 6ES7 138-4GA00-0AB0 6ES7 338-7XF00-0AB0

3SF7 240-3JQ00 3SF7 210-3JQ00 3SF7 241-3JQ00 3SF7 211-3JQ00 3SF7 214-3JQ00 3SF6 232-3JA00

3SF6 233-3JA00

Status information/ alarms/diagnostics Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 250 g 40 mm 125 mm 120 mm No Yes 500 VDC Yes

IQ-Sense proximity switches

More information
More information as of page 5/333

5/76

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


Overview

Overview
Technology module for ET 200S: SSI module 2 PULSE pulse generator 1 STEP step module 1 POS U positioning module 1 COUNT 5 V/500 kHz counter module 1 COUNT 24 V/100 kHz counter module 1SI interface module Note: We offer incremental encoders and prefabricated connecting cables for counter and positioning functions under SIMODRIVE Sensor and Motion Connect 500 (see also http://www.siemens.com/simatic-technology)

Design
TM-E terminal module and electronic module combination options
Electronic modules Screw-type terminal Order No. 6ES7 193 Spring-loaded terminal Order No. 6ES7 193 Fast Connect Order No. 6ES7 193 1 COUNT 24 V/100 kHz 1 COUNT 5 V/500 kHz 1 SSI 1 STEP 5 V/204 kHz 2 PULSE 1 POS U 1 SI 3964/ASCII 1 SI Modbus/USS
1)

TM-E terminal modules for electronic modules 15S26-A1 4CA40-0AA0 15C26-A1 4CA50-0AA0 15N26-A1 4CA80-0AA0
n

5
15S23-01 15C23-01 15N23-01 15S24-AT 15C24-AT 30S44-01 30C44-01 30S46-A1 30C46-A1 -

15S24-A1 15C24-A1 15N24-A1

15S24-01 15C24-01 15N24-01


n

4CA20-0AA0 4CB20-0AA0 4CB00-0AA0 4CL20-0AA0 4CG20-0AA0 4CF40-0AA0 4CA30-0AA0 4CB30-0AA0 4CB10-0AA0 4CL30-0AA0 4CG30-0AA0 4CF50-0AA0 4CA70-0AA0 4CB70-0AA0 4CB60-0AA0
n

n n n

n n n n

n n

n n

See Manual "ET 200S Fail-safe Modules" in the documentation packages "S7 F Systems" and "S7 Distributed Safety"

Siemens IK PI 2009

5/77

Siemens AG 2008

ET 200S Technology modules


SSI module

SIMATIC ET 200 distributed I/Os

Overview
1-channel module for connecting SSI sensors to the ET 200S For position decoding and simple positioning tasks With two comparison operations with specifiable comparison values (standard mode) With a digital input for latching actual values (standard mode) Can be plugged into TM-E terminal module with automatic coding Fast mode for high-speed acquisition of encoder values (e.g. for drive controls) Module replacement possible during operation and when live (hot swapping) Simple parameterization without additional software Note: We supply positioning systems and prepared connection cables for counting and positioning functions as SIMODRIVE Sensors or Motion Connect 500 (also visit http://www.siemens.com/simatic-technology)

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. Power loss, typ. Hardware config. Module exchange Hot swapping the IM-DP Module exchange under process voltage Digital inputs Number of digital inputs Cable length cable length, shielded, max. Input voltage for signal "0" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Encoder supply 24 V encoder supply 24 V Short-circuit protection Output current, max. Absolute encoder (SSI) encoder supply Absolute encoder (SSI) Output current, max. Short-circuit protection Yes 500 mA Yes Yes Yes 500 mA 2 mA 9 mA -30 ... 5 V 50 m 1 Yes Yes 40 mA 1W 24 V Yes 28.8 V 6ES7 138-4DB03-0AB0 Order No. Encoder Number of connectable encoders, max. Connectable encoders Absolute encoder (SSI) Encoder signals, absolute encoder (SSI) Telegram length cable length, shielded, max. Monoflop time Status information/ alarms/diagnostics Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Status indicator backward counting (green) Status indicator forward counting (green) Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation counter between the channels and the backplane bus between the channels and the load voltage L+ Dimensions Dimensions Width Height Depth Weights Weight, approx. 40 g 15 mm 81 mm 52 mm Yes No No; same potential with L+ and SSI Yes Yes Yes Yes 13, 14, 16, 21, 24 & 25 bit 320 m; at 125 kHz 16/32/48/64 s Yes 1 6ES7 138-4DB03-0AB0

permissible range, lower limit (DC) 20.4 V

5/78

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


SSI module

Ordering data
SSI module for connecting absolute encoders with an SSI interface Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige Signal cable Preassembled for SSI absolute encoder 6FX2001-5, without Sub-D connector, UL/DESINA

Order No. 6ES7 138-4DB03-0AB0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 6FX5 002-2CC12-....

Siemens IK PI 2009

5/79

Siemens AG 2008

ET 200S Technology modules


2 PULSE pulse generator

SIMATIC ET 200 distributed I/Os

Overview
2-channel pulse generator and timer module for ET 200S For controlling final control elements, valves, heater elements, etc. Pulse width modulation (PWM) Pulse sequences Pulse trains Accurately timed switching signals to 24 V DC output

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. Power loss, typ. Digital inputs Number of digital inputs Cable length cable length, shielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) Input frequency (with 0.1 ms delay), max. Minimum pulse width for program reactions

6ES7 138-4DD00-0AB0

Order No. Digital outputs Number of digital outputs

6ES7 138-4DD00-0AB0 2 1 000 m 600 m 10 A L+ (-50 to -65 V) 10 W +/- (pulse duration x 100 ppm) , +/-100 s with a load <= 50 ohms 200 s Yes L+ (-1 V) 2A 7 mA 2A

24 V; From power module Yes 40 mA

cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Accuracy of pulse duration

Short-circuit protection of the output Yes

from backplane bus 3.3 V DC, max. 10 mA 1.8 W 2

minimum pulse duration 100 m Yes Controlling a digital input Output voltage for signal "1", min. Output current 24 V -30 to +5 V 11 to 30 V 9 mA for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load 20 kHz 100 s "0" to "1", max. "1" to "0", max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max.

for signal "0" residual current, max. 0.5 mA 100 s 200 s 2.5 kHz 2 Hz 10 Hz

5/80

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


2 PULSE pulse generator

Technical specifications (continued)


Order No. Encoder supply Output voltage Output current, rated value Short-circuit protection Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2wire BEROS), max. Pulse generator Number of channels Status information/ alarms/diagnostics Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Isolation, digital outputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx. 40 g 15 mm 81 mm 52 mm 75 VDC / 60 VAC No Yes No Yes 500 VDC Yes Yes Yes 2; 1 digital input and 1 digital output per channel Yes 2 mA L+ (-0.8 V) 500 mA Yes 6ES7 138-4DD00-0AB0

Ordering data
Pulse generator and timer module 2PULSE for ET 200S Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige

Order No. 6ES7 138-4DD00-0AB0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0

Siemens IK PI 2009

5/81

Siemens AG 2008

ET 200S Technology modules


1 STEP step module

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption Power loss, typ. Digital inputs Number of digital inputs Functions 2 Input REF: reference cams, input DI: pulse disable or external stop 1 000 m 600 m 1 kHz Yes 1.5 W 24 V 6ES7 138-4DC00-0AB0

Cable length cable length, shielded, max. Cable length unshielded, max. Repeat frequency, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. - at "1" to "0", max. Encoder Connectable encoders 2-wire BEROS Drive technology Cable length, max. Step controllers Connection for stepper motors Differential signals for pulses (PULSE, notPULSE) and direction (DIR, notDIR) to RS422 1 100 m; twisted and shielded in pairs Yes 300 s 300 s 2 mA 9 mA 24 V -30 to +5 V (-15% / +20%) 11 to 30 V

Single channel module for ET 200S for the controlled positioning of a stepper motor Reference point or incremental operating modes Connection of power circuits with pulse/ direction interface using 5 V differential signals External stop with/without ramp through digital input Status display and error display by LED: positioning errors and status errors in the digital inputs are displayed on LEDs and indicated to the interface to the master

Number of stepper motor channels Status information/ alarms/diagnostics Diagnostics indication LED Description Positioning mode POS (green) Collective error SF (red) Status indicator digital input (green) Dimensions Dimensions Width Height Depth Weights Weight, approx.

1 green LED for status indication "Ready for positioning jobs" Yes Yes Yes

15 mm 81 mm 52 mm 40 g

5/82

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


1 STEP step module

Ordering data
1 STEP Stepper module for simple positioning tasks with stepper motor axes Accessories Label sheets DIN A4 (10 items) Each sheet contains 60 label strips for peripheral modules and 20 label strips for interface modules petrol red yellow light beige SIMOSTEP Stepper motors FM STEPDRIVE Power module for stepper motors

Order No. 6ES7 138-4DC00-0AB0

6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 See Catalog ST 70 See Catalog ST 70

Siemens IK PI 2009

5/83

Siemens AG 2008

ET 200S Technology modules


1 POS U positioning module

SIMATIC ET 200 distributed I/Os

Overview
Positioning module 1 POS U is a single-channel positioning module for ET 200S for the positioning of positioning and operational axes For controlled positioning using digital outputs according to the rapid/creep feed principle With actual position value sensing for - Incremental encoders with 5 V difference signals or 24 V signals, or for SSI encoders - Proportioning mode (single evaluation of encoder signal A only) Reference-point approach, actual value setting Parameter change during operation - Reversing difference - Shutdown difference Functions - Inching: Direct application of control signals by the master - Traversing: Absolute or relative - Axes: For linear and rotary axes - Latch function: Saves the current value by setting a digital input Note: Siemens is offering position measuring systems and pre-assembled connecting cables for counting and positioning functions under SIMODRIVE Sensor or Motion Connect 500.

Technical specifications
Order No. Voltages and currents Load voltage L+ 6ES7 138-4DL00-0AB0 Order No. Digital outputs cable length, shielded, max. 24 V Yes 28.8 V Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. 50 mA Controlling a digital input Output voltage Rated value (DC) for signal "0" (DC), max. for signal "1", min. Output current 50 m Yes for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. 24 V -30 to +5 V 11 to 30 V 2 mA 9 mA Output delay with resistive load "0" to "1", max. "1" to "0", max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Encoder supply 5 V encoder supply 5V 24 V encoder supply 24 V Short-circuit protection Output current, max. Absolute encoder (SSI) encoder supply Absolute encoder (SSI) Output voltage Output current, max. Short-circuit protection Yes L+ (-0.8 V) 500 mA Yes Yes Yes 500 mA No 100 Hz 2 Hz 10 Hz typ. 150 s typ. 150 s 7 mA 600 mA 24 V 3V L+ (-1 V) 2W 1 000 m 600 m 0.7 to 1.8 A yes; L+ -(55 to 60 V) 5W Yes 6ES7 138-4DL00-0AB0

Rated value (DC) reverse polarity protection permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. Power loss, typ. Digital inputs Cable length Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ.

Short-circuit protection of the output Yes

permissible range, lower limit (DC) 20.4 V

from backplane bus 3.3 V DC, max. 10 mA

for signal "0" residual current, max. 0.3 mA

5/84

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


1 POS U positioning module

Technical specifications (continued)


Order No. Encoder Number of connectable encoders, max. Connectable encoders Incremental encoder (symmetrical) Incremental encoder (asymmetrical) Absolute encoder (SSI) 2-wire BEROS Encoder signals, incremental encoder (symmetrical) Encoder signal 5 V - Signal level - Terminating resistor - Differential input voltage, min. - Input frequency, max. - cable length, shielded, max. Encoder signal 24 V - Rated value DC 24 V - Input voltage for signal "0" - Input voltage for signal "1" - Input current, for signal "0", max. (permissible idle current) - Input current for signal "1", typ. - Input frequency, max. - cable length, shielded, max. Encoder signals, absolute encoder (SSI) cable length, shielded, max. 320 m at 125 kHz; 160 m at 250 kHz; 60 m at 500 kHz; 20 m at 1 MHz; 8 m at 2 MHz; twisted in pairs and shielded 7 ms 13 ms 64 ms Order No. 6ES7 138-4DL00-0AB0 Yes 5V 30 V 2 mA 9 mA 100 kHz 50 m to RS-422 330 1V 500 kHz 50 m Yes Yes Yes Yes; Type 2 Status information/ alarms/diagnostics Diagnostics indication LED Actual value falling DN (green) Actual value rising UP (green) Positioning mode POS (green) Collective error SF (red) Status indicator digital input (green) Isolation between backplane bus and all other circuit parts between the channels and backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 65 g 30 mm 81 mm 52 mm Yes Yes Yes Yes Yes Yes Yes Reaction time at switchover/off time 1 6ES7 138-4DL00-0AB0 Order No. Reaction times Updating time of the feedback messages Latch 1 ms In the case of incremental encoders: typ. 400 ms; in the case of SSI encoders: typ. 400 ms + age of the encoder value: In the case of incremental encoders: output delay + 30 s; in the case of SSI encoders: output delay + message frame runtime + 30 ms 6ES7 138-4DL00-0AB0

Updating the encoder value - Telegram runtime at 13 bit, min. - Telegram runtime at 25 Bit, min. Monoflop time

Ordering data
1POS U positioning module Single-channel positioning module for ET 200S for positioning the adjustment and operation axes

Siemens IK PI 2009

5/85

Siemens AG 2008

ET 200S Technology modules


1 COUNT 24 V/100 kHz counter module

SIMATIC ET 200 distributed I/Os

Overview
1-channel 32-bit intelligent counter module for universal count tasks and time-based measuring tasks For the direct connection of 24 V incremental sensors or initiators Comparison function with predefinable comparison values Integrated digital output to output the reaction when the comparison value is attained Can be plugged into TM-E terminal module with automatic coding Module replacement possible during operation and under power (hot swapping) Simple parameterization without additional software Note: Siemens is now able to offer distance measuring systems and pre-assembled connecting cables for counting and positioning functions in the product ranges SIMODRIVE Sensor and Motion Connect 500.

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. Power loss, typ. Hardware config. Module exchange Hot swapping the IM-DP Module exchange under process voltage Digital inputs Number of digital inputs Functions Cable length cable length, shielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max.

6ES7 138-4DA04-0AB0

Order No. Digital outputs Number of digital outputs

6ES7 138-4DA04-0AB0 1 1 000 m 600 m 2.6 to 4 A L+ (-50 to -60 V) 5W Yes 24 V 3V L+ (-1 V) 5 mA 2 000 mA 5 mA 500 mA; 1000 mA at 50 C

24 V Yes 28.8 V

cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to

permissible range, lower limit (DC) 20.4 V

Short-circuit protection of the output Yes

42 mA

Lamp load, max. Controlling a digital input Output voltage Rated value (DC) for signal "0" (DC), max. for signal "1", min. Output current for signal "1" permissible range for 0 to 40 C, min.

from backplane bus 3.3 V DC, max. 10 mA 1W

Yes Yes

1 Gate control, synchronization, latch function 100 m; Filter 20 kHz: 100 m, filter 200 kHz: 50 m Yes

for signal "1" permissible range for 0 to 40 C, max. for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load "0" to "1", max.

for signal "0" residual current, max. 0.5 mA 100 s 100 Hz 2 Hz 10 Hz

24 V -30 to +5 V 11 to 30 V 2 mA 9 mA

Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Encoder supply 24 V encoder supply 24 V Short-circuit protection Output current, max. Yes; L+ (-0.8 V) Yes 500 mA

2.5 s; Filter off: 2.5 s (200 kHz), filter on: 25 s (20 kHz)

5/86

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


1 COUNT 24 V/100 kHz counter module

Technical specifications (continued)


Order No. Encoder Number of connectable encoders, max. Connectable encoders Incremental encoder (asymmetrical) 24 V initiator 2-wire BEROS Counters Number of counter inputs Minimum pulse width Frequency measurement Measurement range, min. Measurement range, max. Cycle duration measurement Measuring range, lower limit Measuring range, upper limit Speed measurement Measurement range, min. (lower limit) Measurement range, max. (upper limit) Parameter Remark 16 byte 1 1 /min 25 000 1 /min 10 s 120 s 0.1 Hz 100 kHz 1; 32 bit 2.5 s; Filter off: 2.5 s (200 kHz), Filter on: 25 s (20 kHz) Yes Yes Yes 1 6ES7 138-4DA04-0AB0 Order No. Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green) Status indicator backward counting (green) Status indicator forward counting (green) Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation counter between the channels and the backplane bus between the channels and the load voltage L+ Dimensions Dimensions Width Height Depth Weights Weight, approx. 40 g 15 mm 81 mm 52 mm Yes No No; only opposite shielding Yes Yes Yes Yes Yes Yes 6ES7 138-4DA04-0AB0

Siemens IK PI 2009

5/87

Siemens AG 2008

ET 200S Technology modules


1 COUNT 24 V/100 kHz counter module

SIMATIC ET 200 distributed I/Os

Ordering data
1 COUNT 24 V/100 kHz counter module For universal counting and measuring tasks with ET 200S Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for I/O modules and 20 label strips for interface modules petrol red yellow light beige Shield connection element For TM-P and TM-E terminal modules, as fixing for busbars 3 x 10 mm, 5 pieces Shield clamps

Order No. 6ES7 138-4DA04-0AB0 SIMODRIVE sensor incremental encoder Externally mounted encoder, optical, incremental with HTL level, operating voltage 10 to 30 V With synchronous flange, universal axial/radial cable outlet with connector - 100 pulses/revolution 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 6ES7 193-4GA00-0AA0 - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution With synchronous flange, radial flange outlet - 100 pulses/revolution - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution 6ES7 193-4GB00-0AA0 With synchronous flange, axial flange outlet - 100 pulses/revolution - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution With clamping flange, universal axial/radial cable outlet with connector - 100 pulses/revolution - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution With clamping flange, radial flange outlet - 100 pulses/revolution - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution With clamping flange, axial flange outlet - 100 pulses/revolution - 500 pulses/revolution - 1000 pulses/revolution - 2500 pulses/revolution Signal cable Pre-assembled for HTL and TTL encoder, without Sub-D connector, UL/DESINA

Order No.

6FX2 001-4DA10 6FX2 001-4DA50 6FX2 001-4DB00 6FX2 001-4DC50

6FX2 001-4FA10 6FX2 001-4FA50 6FX2 001-4FB00 6FX2 001-4FC50

For connecting braided cable shields to the busbar, 5 pieces

6FX2 001-4HA10 6FX2 001-4HA50 6FX2 001-4HB00 6FX2 001-4HC50

6FX2 001-4NA10 6FX2 001-4NA50 6FX2 001-4NB00 6FX2 001-4NC50

6FX2 001-4QA10 6FX2 001-4QA50 6FX2 001-4QB00 6FX2 001-4QC50

6FX2 001-4SA10 6FX2 001-4SA50 6FX2 001-4SB00 6FX2 001-4SC50 6FX5 002-2CA12-....

More information
Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

5/88

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules

SIPLUS 1 COUNT 24 V/100 kHz counter module (extended temperature range)

Overview

Ordering data
SIPLUS counter module 1 COUNT 24 V/100 kHz For universal counting and measuring tasks with ET 200S Accessories

Order No. 6AG1 138-4DA04-2AB0

see "1 COUNT 24 V/100 kHz counter module" ordering data

Single-channel, intelligent 32 bit counter module for universal counting and measuring tasks For direct connection of 24 V incremental encoders or initiators Comparison functions with definable comparison values Integrated digital output for output of the response on reaching the comparison value Can be plugged onto TM-E terminal modules with automatic coding Hot swapping of modules is possible Simple parameterization without additional software Note: We offer position encoding systems and preassembled connecting cables for counting and positioning functions under SIMODRIVE Sensor or Motion Connect 500.
SIPLUS counter module 1 Count 24 V/100 kHz Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 138-4DA04-2AB0 6ES7 138-4DA04-0AB0 -25 ... +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Siemens IK PI 2009

5/89

Siemens AG 2008

ET 200S Technology modules


1 COUNT 5 V/500 kHz counter module

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. Power loss, typ. Hardware config. Module exchange 45 mA 24 V Yes 28.8 V 6ES7 138-4DE02-0AB0

permissible range, lower limit (DC) 20.4 V

from backplane bus 3.3 V DC, max. 10 mA 2W

1-channel 32-bit intelligent counter module for universal count tasks and time-based measuring tasks For direct connection of 5 V incremental encoders (RS 422) Comparison function with predefinable comparison values 2 integrated digital outputs to output the response upon reaching the comparison value Can be plugged into TM-E terminal module with automatic coding Module replacement possible during operation and under power (hot swapping) Simple parameterization without additional software Note: Siemens is now able to offer distance measuring systems and pre-assembled connecting cables for counting and positioning functions in the product ranges SIMODRIVE Sensor and Motion Connect 500.

Hot swapping the IM-DP Module exchange under process voltage Digital inputs Number of digital inputs Functions Cable length cable length, shielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max.

Yes Yes

1 Gate control, synchronization, latch function 50 m Yes

24 V -30 to +5 V 11 to 30 V 2 mA 9 mA

2.5 s

5/90

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


1 COUNT 5 V/500 kHz counter module

Technical specifications (continued)


Order No. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage Rated value (DC) for signal "0" (DC), max. for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load "0" to "1", max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Encoder supply 24 V encoder supply 24 V Short-circuit protection Output current, max. Encoder Number of connectable encoders, max. Connectable encoders Incremental encoder (symmetrical) 2-wire BEROS Encoder signals, incremental encoder (symmetrical) Trace mark signals Zero mark signal Input signal Input frequency, max. cable length, shielded, max. A, notA, B, notB; A and B offset by 90 N, notN 5 V difference signal (phys. RS 422) 650 kHz 50 m Yes Yes 1 Yes; L+ (-0.8 V) Yes 500 mA 100 Hz 2 Hz 10 Hz 100 s 2A 5 mA 2.4 A 24 V 3V L+ (-1 V) 2 1 000 m 600 m 2.6 to 4 A L+ (-50 to -60 V) 10 W Yes 6ES7 138-4DE02-0AB0 Order No. Counters Number of counter inputs Frequency measurement Measurement range, min. Measurement range, max. Cycle duration measurement Measuring range, lower limit Measuring range, upper limit Speed measurement Measurement range, min. (lower limit) Measurement range, max. (upper limit) Parameter Remark Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green) Status indicator backward counting (green) Status indicator forward counting (green) Synchronization SYN (green) Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation counter between the channels and the backplane bus between the channels and the load voltage L+ Dimensions Dimensions Width Height Depth Weights Weight, approx. 65 g 30 mm 81 mm 52 mm Yes No No; only opposite shielding Yes Yes Yes Yes Yes Yes Yes 16 byte 1 1 /min 25 000 1 /min 10 s 120 s 0.1 Hz 500 kHz 1; 32 bit 6ES7 138-4DE02-0AB0

Short-circuit protection of the output Yes

for signal "0" residual current, max. 0.5 mA

Siemens IK PI 2009

5/91

Siemens AG 2008

ET 200S Technology modules


1 COUNT 5 V/500 kHz counter module

SIMATIC ET 200 distributed I/Os

Ordering data
1 COUNT 5 V/500 kHz counter module For universal counting and measuring tasks with ET 200S Accessories Label sheets DIN A4 (10 pieces) Each sheet contains 60 label strips for I/O modules and 20 label strips for interface modules petrol red yellow light beige Shield connection element For TM-P and TM-E terminal modules, as fixing for busbars 3 x 10 mm, 5 pieces

Order No. 6ES7 138-4DE02-0AB0 With synchronous flange, axial flange outlet - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution 6ES7 193-4BH00-0AA0 6ES7 193-4BD00-0AA0 6ES7 193-4BB00-0AA0 6ES7 193-4BA00-0AA0 6ES7 193-4GA00-0AA0 - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution With clamping flange, universal axial/radial cable outlet with connector - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution 6ES7 193-4GB00-0AA0 - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution With clamping flange, radial flange outlet 6FX2 001-2DA50 6FX2 001-2DB00 6FX2 001-2DB02 6FX2 001-2DB25 6FX2 001-2DB50 6FX2 001-2DC00 6FX2 001-2DC04 6FX2 001-2DC50 6FX2 001-2DD60 6FX2 001-2DF00 - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution With clamping flange, axial flange outlet - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution Signal cable Pre-assembled for HTL and TTL encoder, without Sub-D connector, UL/DESINA

Order No.

6FX2 001-2HA50 6FX2 001-2HB00 6FX2 001-2HB02 6FX2 001-2HB25 6FX2 001-2HB50 6FX2 001-2HC00 6FX2 001-2HC04 6FX2 001-2HC50 6FX2 001-2HD60 6FX2 001-2HF00

6FX2 001-2NA50 6FX2 001-2NB00 6FX2 001-2NB02 6FX2 001-2NB25 6FX2 001-2NB50 6FX2 001-2NC00 6FX2 001-2NC04 6FX2 001-2NC50 6FX2 001-2ND60 6FX2 001-2NF00

Shield clamps For connecting braided cable shields to the busbar, 5 pieces SIMODRIVE Incremental shaft encoder with RS 422 (TTL), operating voltage 10 to 30 V With synchronous flange, universal axial/radial cable outlet with connector - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution With synchronous flange, radial flange outlet - 500 pulses/revolution - 1000 pulses/revolution - 1024 pulses/revolution - 1250 pulses/revolution - 1500 pulses/revolution - 2000 pulses/revolution - 2048 pulses/revolution - 2500 pulses/revolution - 3600 pulses/revolution - 5000 pulses/revolution

6FX2 001-2QA50 6FX2 001-2QB00 6FX2 001-2QB02 6FX2 001-2QB25 6FX2 001-2QB50 6FX2 001-2QC00 6FX2 001-2QC04 6FX2 001-2QC50 6FX2 001-2QD60 6FX2 001-2QF00

6FX2 001-2FA50 6FX2 001-2FB00 6FX2 001-2FB02 6FX2 001-2FB25 6FX2 001-2FB50 6FX2 001-2FC00 6FX2 001-2FC04 6FX2 001-2FC50 6FX2 001-2FD60 6FX2 001-2FF00

6FX2 001-2SA50 6FX2 001-2SB00 6FX2 001-2SB02 6FX2 001-2SB25 6FX2 001-2SB50 6FX2 001-2SC00 6FX2 001-2SC04 6FX2 001-2SC50 6FX2 001-2SD60 6FX2 001-2SF00 6FX5 002-2CA12-....

More information
Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

5/92

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


1SI interface module

Overview
1-channel module for serial data exchange through point-to-point connection For message frames max. 200 byte long RS 232C, RS 422, RS 485 2 versions - ASCII and 3964(R) protocol - Modbus and USS protocol Parameter assignment through GSD file or STEP 7 (V5.1 and newer)

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from backplane bus DC 24 V, max. 80 mA; typ. 20 mA 1.2 W 80 mA 10 mA 1.2 W 24 V 24 V 6ES7 1384DF01-0AB0 6ES7 1384DF11-0AB0 Order No. Point-to-point Integrated protocol driver 3964 (R) ASCII Modbus Transmission speed, Modbus protocol, max. Yes Yes Yes 115.2 kBit/s; half duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps Yes 115.2 kBit/s; half duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps 115.2 kBit/s; half duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps 115.2 kBit/s; full duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps 6ES7 1384DF01-0AB0 6ES7 1384DF11-0AB0

from backplane bus 3.3 V DC, max. 10 mA Power loss, typ. Memory Type of storage Standard blocks 5 100 Byte; S_SEND 2700, S_RCV 2400, S_XON 2600, S_RTS 2600, S_V24 2700, S_VSTAT 1800, S_VSET 1800

11 100 Byte; Modbus: S_SEND 2700, S_RCV 2400, S_MODB 6000; USI: S_SEND 2700, S_RCV 2400, S_USST 1900, S_USSR 2600, S_USSI 1500 1 Yes; RS 232C signals: 8 (TxD, RxD, RTS, CTS, DTR, DSR, DCD, PE) Yes; RS-422 signals: 5 (TxD(A), RxD(A), TxD(B), RxD(B), PE); RS-485 signals: 3 (R/T(A), R/T(B), PE) 15 m 1 200 m

USS Transmission speed, USS protocol, max.

interfaces Number of interfaces RS 232C 1 Yes; RS 232C signals: 8 (TxD, RxD, RTS, CTS, DTR, DSR, DCD, PE) Yes; RS-422 signals: 5 (TxD(A), RxD(A), TxD(B), RxD(B), PE); RS-485 signals: 3 (R/T(A), R/T(B), PE) 15 m 1 200 m

Transmission speed, RS 422/485 with 3964 (R) protocol, max.

RS 422/RS 485

with ASCII protocol, max.

RS 232, cable length, shielded, max. RS 422/485, cable length, shielded, max.

Siemens IK PI 2009

5/93

Siemens AG 2008

ET 200S Technology modules


1SI interface module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Transmission speed, RS232 with 3964 (R) protocol, max. 115.2 kBit/s; half duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps 115.2 kBit/s; full duplex: 110, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps 7 or 8 1 or 2 10 none, odd, even, any 8 1 or 2 (USS only 1) 10 or 11 (USS only 11 bits) none, odd, even (USI even only) 6ES7 1384DF01-0AB0 6ES7 1384DF11-0AB0 Order No. Status information/ alarms/diagnostics Diagnostics indication LED Receive RxD (green) Collective error SF (red) Transmit TxD (green) Isolation Isolation interface between 422/485 and internal power supply between RS 232 and internal power supply Environmental requirements Operating termperature min. max. Storage/transport temperature min. max. Dimensions Dimensions 32 Byte; with IM151-1 Standard as of 6ES7 1511AA04-0AB0; with IM151-1 High Feature as of 6ES7 1511BA01-0AB0; otherwise 8 bytes 32 Byte; With IM151-1 Standard as of 6ES71511AA04-0AB0; With IM151-1 High Feature as of 6ES71511BA01-0AB0; otherwise 8 bytes Order No. Accessories (continued) 6ES7 138-4DF01-0AB0 6ES7 138-4DF11-0AB0 6ES7 193-4CA40-0AA0 TM-E15N24-A1 terminal module Ordering unit 5 items TM-E15S24-01 terminal module Ordering unit 5 items TM-E15C24-01 terminal module Ordering unit 5 items 6ES7 193-4CA50-0AA0 TM-E15N24-01 terminal module Ordering unit 5 items 6ES7 193-4CB70-0AA0 6ES7 193-4CB30-0AA0 6ES7 193-4CB20-0AA0 6ES7 193-4CA80-0AA0 32 Byte; with IM151-1 Standard as of 6ES7 1511AA04-0AB0; with IM151-1 High Feature as of 6ES7 1511BA01-0AB0; otherwise 8 bytes 32 Byte; With IM151-1 Standard as of 6ES71511AA04-0AB0; With IM151-1 High Feature as of 6ES71511BA01-0AB0; otherwise 8 bytes Order No. Width Height Depth Weights Weight, approx. 50 g 50 g 15 mm 81 mm 52 mm 15 mm 81 mm 52 mm -40 C 70 C -40 C 70 C 0 C 60 C 0 C 60 C Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 1384DF01-0AB0 6ES7 1384DF11-0AB0

with ASCII protocol, max.

Character frame (adjustable) Bits per character Number of start/stop bits Bits per character frame Parity Number of bytes per PLC sampling cycle Data quantity per PLC sampling cycle, receiving

Data quantity per PLC sampling cycle, transmitting

Ordering data
1 SI interface module ASCII and 3964(R) protocols Modbus and USS protocols Accessories TM-E15S 26-A1 terminal module Ordering unit 5 items TM-E15S 26-A1 terminal module Ordering unit 5 items

5/94

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


SIWAREX CS

Overview

Design
SIWAREX CS is a compact function module (FM) in the SIMATIC ET 200S and can be plugged directly into a terminal module. The power supply is connected through a power module and the internal power rail. The load cells and the serial interfaces are connected through the terminals of the terminal module. Using the terminal module enables the module to be replaced without disconnecting the connecting cables.

Function
The primary task of SIWAREX CS is the measurement of sensor voltage and the conversion of this measurement into a weight value. Up to 3 interpolation points are used for the weight calculation. The signal can also be digitally filtered if required. As well as determining weights, the SIWAREX CS monitors two freely programmable limits (min./max. as required) and notifies SIMATIC if these values are exceeded.
SIWAREX CS weighing electronics

SIWAREX CS is a versatile weighing module for all simple weighing and force measuring tasks. The compact module is easy to install in all SIMATIC automation systems. Data can be accessed directly in the SIMATIC.

The SIWAREX CS comes factory-calibrated. This means that theoretical adjustment of the scale is possible without adjustment weights, and that modules can be replaced without the need to readjust the scale. Consistent and uniform communication between all system components enables fast, reliable and cost-effective integration and diagnosis in industrial processes. The following tables show the accessible functions. Communication in SIMATIC
Supports the readout of data through peripherals IM151-1 Basic IM151-1 Standard IM151-1 High Feature IM151-7 CPU Yes Yes Yes Yes Supports the readout of data and settings using record communication No Yes Yes Yes

Benefits
SIWAREX CS offers the following key advantages: Uniform design technology and consistent communication in SIMATIC Uniform configuration with SIMATIC Use in distributed plant concept through connection to PROFIBUS DP or PROFINET via ET 200S Measurement of weight or force with a high resolution of 65000 parts and an accuracy of 0.05 % Direct connection of a remote display to the TTY interface Simple adjustment of scale using the SIWATOOL CS program via the RS 232 interface Supports theoretical adjustment without adjustment weights Supports replacement of module without renewed adjustment of scale For use in Ex zone 2, intrinsically-safe load cell powering for zone 1 using Ex interface.

Alarms in SIMATIC
Group diagnostics IM151-1 Basic IM151-1 Standard IM151-1 High Feature IM151-7 CPU Yes Yes Yes Yes Process alarm No Yes Yes Yes

Application
SIWAREX CS is the optimum solution wherever strain gauge sensors, such as load cells, force sensors or torque measuring shafts, are used for measuring tasks. The following are typical SIWAREX CS applications: Non-automatic weighing machines Fill level monitoring of silos and bunkers Measuring of crane and cable loads Load measuring of industrial lifts and roll trains Weighing in potentially explosive areas (zone 2 direct, zone 1 using Ex interface SIWAREX IS) Monitoring of belt tension Force measuring, container weighers, platform scales and crane scales

Siemens IK PI 2009

5/95

Siemens AG 2008

ET 200S Technology modules


SIWAREX CS

SIMATIC ET 200 distributed I/Os

Function (continued)
The SIWAREX CS has two serial interfaces. The TTY interface serves to connect digital remote displays. The remote displays can show the weight value with status information. To parameterize the SIWAREX CS, a PC can be connected over the RS 232 interface. SIWAREX CS can be integrated in the plant software using the classic PLC programming languages; STL (Statement List), LD (Ladder Diagram) SFC (Sequential Function Chart) or SCL (Structured Control Language). In contrast to serially linked weighing electronics, SIWAREX CS does not need costly additional modules to link it to SIMATIC. Used in conjunction with SIWAREX CS, it is possible to configure freely programmable, modular weighing systems in SIMATIC.

Technical specifications
SIWAREX CS Integration in automation systems S7-400, S7-300, C7 IM151-7 CPU Automation systems from other manufacturers (available soon) Communication interfaces Connection of remote displays (through TTY serial interface) Adjustment of scales settings Through ET 200S Through backplane bus Through ET 200S SIMATIC S7 (ET 200S backplane bus), RS 232, TTY Display for weight value Using SIMATIC S7/C7 IM151-7 CPU or SIWATOOL CS PC parameterization software (RS 232) 0.05 % 65535 2 byte (fixed-point) 50 0.05 - 5 Hz (in 7 steps), mean-value filter Gross, net 2 (min./max.) Per command Per command Per command Strain gages in 4-wire or 6-wire system 6 V DC typ. 68 mA > 87 < 4010 With SIWAREX IS Ex interface: > 87 < 4010 1 mV/V to 4 mV/V -2,4 ... +26.4 mV

Measuring properties Error limit to DIN 1319-1 of full-scale value at 20 C 10 K Internal resolution Data format of weight values Number of measurements/second Digital filter Weighing functions Weight values Limit values Zero setting function Tare function Tare specification Load cells Load cell powering Supply voltage Us (rated value) Max. supply current Scale faceplate in the SIWAREX CS software "Getting started" Permissible load impedance - R Lmin - R Lmax - R Lmin - R Lmax Load cell characteristic Permissible range of measuring signal (at greatest set characteristic value) Max. distance of load cells Intrinsically-safe load cell powering External load cell powering Connection to load cells in Ex zone 1 Ex approvals zone 2 and safety Supply voltage 24 V DC Rated voltage Max. current consumption IP degree of protection to EN 60529; IEC 60529 Climatic requirements T min (IND) to Tmax (IND)) (operating temperature) Vertical installation Horizontal installation EMC requirements according to -10 ... +60 C -10 ... +40 C EN 61326, EN 45501 NAMUR NE21, Part 1 24 V DC 150 mA IP20

In addition to the configuration package, the ready-to-use SIWAREX CS software "Getting started" is also available freeof-charge and shows beginners how to integrate the module into a STEP 7 program and offers a basis for application programming. A SIWAREX CS scale can then be simply implemented in SIMATIC together with a touch panel (TP/OP/MP) as the operator panel. Using the SIWATOOL CS software, the SIWAREX weighing modules offer Windows convenience and are quick to get up and running. Screen forms allow all user-definable parameters of the weighing modules to be specified, saved and printed for plant documentation. The diverse diagnostic options provided by SIWATOOL CS ensure fast fault locating in online mode. The SIWAREX CS weighing module can be used in potentially explosive areas (zone 2). It can also be used in zone 1 by implementing an optional Ex interface, whereby SIWAREX CS must be installed in a safe area.

1000 m Optional (SIWAREX IS Ex interface) Possible up to 24 V Optionally via SIWAREX IS Ex interface ATEX 95, FM, cULUS Haz. Loc.

5/96

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


SIWAREX CS

Ordering data
SIWAREX CS Weighing electronics for scales in SIMATIC ET 200S SIWAREX CS Manual available in a range of languages SIWAREX CS "Getting started" Sample software shows beginners how to program the scales in STEP 7. Configuration package SIWAREX CS on CD-ROM for SIMATIC S7, version V5.4 or higher Software for SIWATOOL CS scale adjustment (in a range of languages) Manuals available on CD (in a range of languages) SIWAREX CS "Getting started" SIWATOOL cable from SIWAREX U/CS with serial PC interface, for 9-pin PC interfaces (RS 232), 3 m long Installation material (mandatory) Terminal module TM-E 30 mm wide (required for each SIWAREX module) Shield contact element Contents 5 items, sufficient for 5 cables Shield connection terminal Contents: 5 items, sufficient for 5 cables Note: one shield connection terminal is required each for the scales connection and TTY interface or RS 232 interface N busbar, galvanized 3 x 10 mm, 1.5 m long Feeder terminal for N busbar Remote displays (option) The digital remote displays can be connected directly to the SIWAREX CS through the TTY interface. The following remote display can be used: S102 Siebert Industrieelektronik GmbH P.O. Box 1180 D-66565 Eppelborn Tel.: 06806/980-0 Fax: 06806/980-999 Internet: http://www.siebert.de Detailed information available from manufacturer.
A)

Order No. 7MH4910-0AA01 Accessories SIWAREX JB junction box, aluminium housing for connecting up to 4 load cells in parallel, and for connecting several junction boxes SIWAREX JB junction box, stainless steel housing for connecting up to 4 load cells in parallel Ex interface, type SIWAREX Pi With UL and FM approvals, but without ATEX approval for intrinsically-safe connection of load cells, suitable for the SIWAREX U, CS, MS, FTA, FTC and M weighing modules. Not approved for use in the EU. Manual for Ex interface type SIWAREX Pi 7MH4607-8CA A) Ex interface, type SIWAREX IS With ATEX approval, but without UL and FM approvals for intrinsically-safe connection of load cells, including manual, suitable for the SIWAREX U, CS, MS, FTA, FTC, M and CF weighing modules. Approved for use in the EU. With short-circuit current < 199 mA DC With short-circuit current < 137 mA DC 6ES7193-4GB00-0AA0 Cable (optional) Cable Li2Y 1 x 2 x 0.75 ST + 2 x (2 x 0.34 ST) - CY, orange sheath to connect SIWAREX U, CS, MS, FTA, FTC, M and CF to the junction box (JB), extension box (EB) or Ex interface (Ex-I) or between two JBs, for fixed laying, occasional bending permitted, 10.8 mm outer diameter, for ambient temperature -40 to +80 C Cable Li2Y 1 x 2 x 0.75 ST + 2 x (2 x 0.34 ST) - CY, blue sheath to connect the junction box (JB) or extension box (EB) in a potentially explosive atmosphere to the Ex interface (Ex-I), for fixed laying, occasional bending permitted, blue PVC insulating sheath, approx. 10.8 mm outer diameter, for ambient temperature -40 ... +80 C Cable LiYCY 4 x 2 x 0.25 mm for TTY (connect 2 pairs of conductors in parallel), for connection of a remote display

Order No.

7MH4710-1BA

Free download in the Internet at: www.siemens.com/ weighing-technology Free download in the Internet at: www.siemens.com/ weighing-technology 7MH4910-0AK01

7MH4710-1EA

7MH4710-5AA

C71000-T5974-C29

6ES7193-4CG20-0AA0 oder kompatibel 6ES7193-4GA00-0AA0

7MH4710-5BA 7MH4710-5CA

7MH4702-8AG

8WA2842 8WA2868

7MH4702-8AF

7MH4407-8BD0 A)

subject to AL export regulations: N, ECCN: EAR99H

Siemens IK PI 2009

5/97

Siemens AG 2008

ET 200S Technology modules


SIWAREX CF

SIMATIC ET 200 distributed I/Os

Overview

Function
SIWAREX CF provides the voltage supply required by the EMS. The force produces a corresponding measuring signal, which is then further processed in the SIWAREX CF module. The signal is amplified, coarse-filtered, and then converted to a digital value. A connectable digital filter can additionally reduce noise on the measuring signal. The digital value is available to the user internally in SIMATIC and can be processed in the control program. For example, the user could further suppress noise through averaging in the SIMATIC CPU or perform a conversion to physical units. The result can be displayed on an operator panel according to requirements. Consistent and uniform communication between all system components enables fast, reliable and cost-effective integration and diagnosis in industrial processes. SIWAREX CF can be integrated into the plant software using the classic PLC programming languages; STL (Statement List), LAD (Ladder Diagram) FBD (Function Block Diagram) or SCL (Structured Control Language). Integration into SIMATIC can result in freely-programmable, modular force measuring systems which can be modified according to operational requirements. The ready-to-use SIWAREX CF software "Getting started" is available free-ofcharge and shows beginners how to integrate the module into a STEP 7 program and offers a basis for application programming. This supports the display of the measured values in a SIMATIC panel (TP/OP/MP).

SIWAREX CF is a transmitter for connecting strain-gauge sensors for tasks such as measuring force and torque. The compact module is easy to install in all SIMATIC automation systems. Complete data access to the current measured values is then possible via the SIMATIC.

Benefits
SIWAREX CF offers the following key advantages: Uniform design technology and consistent communication thanks to integration in SIMATIC Uniform configuration with SIMATIC Use in distributed plant concept through connection to PROFIBUS DP or PROFINET via ET 200S Bidirectional measuring with a resolution of 16000 parts and accuracy of 0.15 %

Application
SIWAREX CF is the optimum solution wherever strain-gauge sensors, such as load cells, force sensors or torque measuring shafts, are used for measuring tasks. The following are typical SIWAREX CF applications: Monitoring of crane and cable loads Measurement of load of conveyor belts Overload protection in rolling mills Monitoring of belt tension Force measurement in testing machines Torque and pressure measuring

Measured values from three modules in the SIWAREX CF "Getting started" software

Design
SIWAREX CF is a compact function module (FM) of the SIMATIC S7 and can be snapped direct onto the SIMATIC ET 200S backplane bus. Assembly and wiring are also greatly simplified by using rails with snap-on technology. The sensors and the power supply are connected via the standard connection block.

In contrast to analog or digitally connected transmitters, SIWAREX M does not need costly additional modules to link it to SIMATIC. After the module has been configured in SIMATIC and installed, it is ready for immediate operation. An additional parameterization tool is not required. The current data are read into the SIMATIC via the I/O area.

5/98

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Technology modules


SIWAREX CF

Technical specifications
SIWAREX CF Integration in automation systems S7-400, S7-300, C7 Automation systems from other vendors Communication interfaces Module parameterization Measuring properties Error limit to DIN 1319-1 of full-scale value at 20 C 10 K Signal resolution Number of measurements/second Low-pass filter Sensors 0.15 % 14 bits plus 1 bit sign 50 Without or 2 Hz In accordance with the principle of expansion measurement (full bridge) 4-wire connection 6 V DC 5 % > 250 < 4010 Up to 4 mV/V -25,2 ... +25.2 mV Through ET 200S Possible through ET 200S with IM 151-1 SIMATIC S7 (ET 200S backplane bus), 8 bytes, I/O area Not required (module is pre-parameterized)

Ordering data
SIWAREX CF Weighing module for strain-gauge sensors in SIMATIC ET 200S (SIWAREX CF configuring package not required) SIWAREX CF manual German, English SIWAREX CF "Getting started" Sample software for easy acquaintance with programming in STEP 7. Installation material (mandatory) Terminal module TM-E 30 mm wide (required for each SIWAREX module) Shield contact element Contents 5 items, sufficient for 5 cables Shield connection terminal Contents: 5 items, sufficient for 5 cables One shield terminal element is required per sensor cable N busbar, galvanized 3 x 10 mm, 1.5 m long Feeder terminal for N busbar Accessories 24 V DC 150 mA Typ. 10 mA Optionally via SIWAREX IS Ex interface ATEX 95, cULus Haz. Loc. IP20 SIWAREX EB extension box for extending sensor cables SIWAREX IS Ex interface With ATEX approval, but without UL and FM approvals, for intrinsically-safe connection of load cells, including Manual, suitable for the SIWAREX U, CS, MS, FTA, FTC and M weighing modules. Approved for use in the EU. With short-circuit current < 199 mA DC 0 ... +60 C 0 ... +40 C NAMUR NE21, Part 1 89/386/EEC With short-circuit current < 137 mA DC Cable (optional) Cable Li2Y 1 x 2 x 0.75 ST + 2 x (2 x 0.34 ST) - CY, orange sheath to connect SIWAREX U, CS, MS, FTA, FTC, M and CF to the junction box (JB), extension box (EB) or Ex interface (Ex-I) or between two JBs, for fixed laying, occasional bending permitted, 10.8 mm outer diameter, for ambient temperature -40 to +80 C

Order No. 7MH4920-0AA01

Free download in the Internet at: www.siemens.com/ weighing-technology Free download in the Internet at: www.siemens.com/ weighing-technology

6ES7193-4CG20-0AA0 oder kompatibel 6ES7193-4GA00-0AA0

Sensor feed Supply voltage, short-circuit-proof Permissible sensor resistance - R Lmin - R Lmax Permissible sensor cell coefficient Permissible range of the measuring signal Supply voltage 24 V DC Rated voltage Max. current consumption Voltage supply from backplane bus Connection to sensors in Ex zone 1 Ex approval zone 2 and safety IP degree of protection to EN 60529; IEC 60529 Climatic requirements Tmin (IND) to Tmax (IND) (operating temperature) Vertical installation Horizontal installation EMC requirements according to

6ES7193-4GB00-0AA0

8WA2842 8WA2868 7MH4710-2AA

7MH4710-5BA 7MH4710-5CA

7MH4702-8AG

Siemens IK PI 2009

5/99

Siemens AG 2008

ET 200S Terminal modules


Terminal modules for power and electronic modules

SIMATIC ET 200 distributed I/Os

Overview
Mechanical modules as receptacles for the electronic modules For setting up permanent wiring via build-as-you-go voltage buses Keyed connection technology to ensure an enhanced vibration resistance of up to 5 g Different variants for accepting power modules and electronic modules Replaceable terminal box (even within the station network) Automatic coding of the electronics modules Build-as-you-go shielding of the backplane bus for high data security Color coding facility for the terminals and for identifying the slot numbers Alternatively available with screw-type or spring-loaded terminals as well as with no-strip fast connection system "FastConnect" for up to 60 % quicker process wiring

Ordering data

Order No. TM-P15N22-01 Ordering unit 1 item 2 x 2 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-P30S44-A0 6ES7 193-4CC30-0AA0 Ordering unit 1 item 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals for PM-E F PROFIsafe TM-P30C44-A0 6ES7 193-4CC70-0AA0 Ordering unit 1 item 7 x 2 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals for PM-E F PROFIsafe

Order No. 6ES7 193-4CE60-0AA0

TM-P terminal modules for PM-E power modules TM-P15S23-A1 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-P15C23-A1 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-P15N23-A1 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-P15S23-A0 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw-type terminals TM-P15C23-A0 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals TM-P15N23-A0 Ordering unit 1 item 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, FastConnect TM-P15S22-01 Ordering unit 1 item 2 x 2 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-P15C22-01 Ordering unit 1 item 2 x 2 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals
1)

6ES7 193-4CC20-0AA0

6ES7 193-4CK20-0AA0

6ES7 193-4CK30-0AA0

6ES7 193-4CD20-0AA0

Terminal module TM-E for electronic modules 1) TM-E15S24-A1 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E15C24-A1 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15S24-01 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E15C24-01 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15S23-01 Ordering unit 5 items 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals 6ES7 193-4CB00-0AA0 6ES7 193-4CB30-0AA0 6ES7 193-4CB20-0AA0 6ES7 193-4CA30-0AA0 6ES7 193-4CA20-0AA0

6ES7 193-4CD30-0AA0

6ES7 193-4CD70-0AA0

6ES7 193-4CE00-0AA0

6ES7 193-4CE10-0AA0

Observe project planning help for selecting the suitable TM-E and TM-P

5/100

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Terminal modules


Terminal modules for power and electronic modules

Ordering data
TM-E15C23-01 Ordering unit 5 items 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15N23-01 Ordering unit 5 items 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-E15N24-01 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-E15S26-A1 Ordering unit 5 items 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E15C26-A1 Ordering unit 5 items 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15N24-A1 Ordering unit 5 items 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-E15N26-A1 Ordering unit 5 items 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, FastConnect TM-E30S44-01 Ordering unit 1 item 4 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E30C44-01 Ordering unit 1 item 4 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E30S46-A1 Ordering unit 1 item 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals TM-E30C46-A1 Ordering unit 1 item 4 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals

Order No. 6ES7 193-4CB10-0AA0 TM-E15S24-AT Ordering unit 1 item for internal temperature compensation with 2 AI TC High Feature, screw-type terminal TM-E15C24-AT 6ES7 193-4CB60-0AA0 Ordering unit 1 item for internal temperature compensation with 2 AI TC High Feature, spring-loaded terminals Accessories for shield connection 6ES7 193-4CB70-0AA0 Shield connection element Ordering unit 5 items For plugging into TM-E and TM-P Shield clamps 6ES7 193-4CA40-0AA0 Ordering unit 5 items For busbar 3 10 mm Grounding terminal Ordering unit 1 item for cable cross-sections up to 25 mm2 3 10 mm busbars Ordering unit 1 item Accessories for coding 6ES7 193-4CA70-0AA0 Color coding plates Ordering unit 200 items for TM-P, TM-E white yellow 6ES7 193-4CA80-0AA0 yellow/green red blue brown 6ES7 193-4CG20-0AA0 turquoise Ordering unit 1200 items, for ET 200S terminal modules, includes 60 strips with 20 labels each 6ES7 193-4CG30-0AA0 white yellow yellow/green red 6ES7 193-4CF40-0AA0 blue brown turquoise Labels, inscribed 6ES7 193-4CF50-0AA0 Ordering unit 1 set 200 units for slot numbering (1 to 20) 10 200 units for slot numbering (1 to 40) 5 200 units for slot numbering (1 to 64) 1 , (1 to 68) 2 Labels, blank 200 units for slot numbering

Order No. 6ES7 193-4CL20-0AA0

6ES7 193-4CL30-0AA0

6ES7 193-4GA00-0AA0

6ES7 193-4GB00-0AA0

8WA2 868

6ES7 193-4CA50-0AA0

8WA2 842

6ES7 193-4LA20-0AA0 6ES7 193-4LB20-0AA0 6ES7 193-4LC20-0AA0 6ES7 193-4LD20-0AA0 6ES7 193-4LF20-0AA0 6ES7 193-4LG20-0AA0 6ES7 193-4LH20-0AA0

6ES7 193-4LA10-0AA0 6ES7 193-4LB10-0AA0 6ES7 193-4LC10-0AA0 6ES7 193-4LD10-0AA0 6ES7 193-4LF10-0AA0 6ES7 193-4LG10-0AA0 6ES7 193-4LH10-0AA0

8WA8 861-0AB 8WA8 861-0AC 8WA8 861-0DA

8WA8 848-2AY

Siemens IK PI 2009

5/101

Siemens AG 2008

ET 200S Terminal modules


Overview

SIMATIC ET 200 distributed I/Os

Terminal modules for power and electronic modules (extended temperature range)

SIPLUS DP TM-P12S23-A0 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CD20-2AA0 6ES7 193-4CD20-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-P15C23-A1 Order No. Order No. based on Ambient temperature range 6AG1 193-4CD30-2AA0 6ES7 193-4CD30-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-E15C24-A1 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CA30-2AA0 6ES7 193-4CA30-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-E15S26-A1 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CA40-2AA0 6ES7 193-4CA40-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-E15C26-A1 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CA50-2AA0 6ES7 193-4CA50-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Technical data

Mechanical modules as receptacles for the electronic modules For setting up permanent wiring via build-as-you-go voltage buses Keyed connection technology to ensure an enhanced vibration resistance of up to 5 g Different variants for accepting power modules and electronic modules Replaceable terminal box (even within the station network) Automatic coding of the electronics modules Build-as-you-go shielding of the backplane bus for high data security Color coding facility for the terminals and for identifying the slot numbers Alternatively available with screw-type or spring-loaded terminals as well as with no-strip fast connection system "FastConnect" for up to 60 % quicker process wiring

Environmental conditions

Technical data

Technical data

Technical data

Technical data

5/102

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Terminal modules

Terminal modules for power and electronic modules (extended temperature range)

Overview (continued)
SIPLUS DP TM-E15C24-A1 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CB30-2AA0 6ES7 193-4CB30-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-E30C44-01 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CG30-2AA0 6ES7 193-4CG30-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules. SIPLUS DP TM-E15C24-A1 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 193-4CL30-2AA0 6ES7 193-4CL30-0AA0 -25 +60 C; condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). The technical data are identical with those of the based-on modules.

Ordering data
(extended temperature range and medium load) TM-P15S23-A0 Ordering unit: 1 unit 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, screw connection TM-P15C23-A0 Ordering unit: 1 unit 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interrupted to the left, spring-loaded terminals

Order No.

TM-P terminal modules for PM-E power modules

6AG1 193-4CD20-2AA0

Technical data

6AG1 193-4CD30-2AA0

TM-E terminal modules for electronic modules (extended temperature range and medium load) TM-E15C24-A1 Ordering unit: 5 units 2 x 4 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15S26-A1 Ordering unit: 5 units 2 x 6 terminals, terminal connections with terminal access to AUX1 bus, AUX1 interconnected, screw terminals TM-E15C26-A1 Ordering unit: 5 units 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15C24-A1 Ordering unit: 5 units 2 x 4 terminals, terminal connections without terminal access to AUX1 bus, AUX1 interconnected, spring-loaded terminals TM-E30C44-01 Ordering unit: 1 unit 4 x 4 terminals, no terminal access to AUX1 bus, AUX1 interconnected to the left, spring-loaded terminals TM-E15C24-AT Ordering unit: 1 unit For internal temperature compensation with 2 AI TC High Feature, spring-loaded terminals Accessories for shield connection see "Terminal modules for power and electronic modules" ordering data 6AG1 193-4CL30-2AA0 6AG1 193-4CG30-2AA0 6AG1 193-4CB30-2AA0 6AG1 193-4CA50-2AA0 6AG1 193-4CA40-2AA0 6AG1 193-4CA30-2AA0

Technical data

Technical data

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

Siemens IK PI 2009

5/103

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


Introduction

SIMATIC ET 200 distributed I/Os

Overview
Motor starters Completely factory-wired motor starters for switching and protecting any AC loads Can be used as a direct-on-line, reversing or soft starter Standard motor starter with motor starter protector and contactor assembly up to 5.5 kW High-feature motor starter with a combination comprising a starter circuit breaker, solid-state overload protection and contactor or soft starter up to 7.5 kW With self-assembling 40/50 A power bus, i.e. the load voltage is only supplied once for a group of motor starters Hot swapping is permissible Inputs and outputs for activating and signaling the statistics have been integrated Diagnostics capability for active monitoring of the switching and protection functions Can be combined with expansion modules: Brake control module for controlling electromechanical brakes in induction motors and with two optional inputs for special functions (for quick stop with the Standard motor starter and for parameterizable special functions with the High-Feature motor starter) For combining with safety technology (see ET 200S Solutions Local/PROFIsafe Safety Motor Starters) for use in safetyrelated system components (EN 954-1) Frequency converters For the continuous speed control of asynchronous motors Comprising modules for the ICU24 control module and IPM25 power section up to 4.0 kW Hot swapping of control module and power section is permissible Low circuit feedback Operation without line commutation reactor Active braking with line-commutated power recovery With self-assembling 50 A power bus, i.e. the load voltage is only supplied once for a group of frequency converters To achieve EMC class A (acc. to EN 55011) Connection of an EMC filter upstream from the power bus

Standard motor starters, DS1-x direct-on-line starters

High-feature motor starters, DS1e-x direct-on-line starters

ET 200S FC frequency converter

5/104

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S motor starters

SIMATIC ET 200 distributed I/Os

Overview
Solid-state modules IM 151 interface module PM-E power module PM-D power module DS1-x standard directon-line starter xB4 brake control module DS1e-x HF high feature direct-online starter DSS1e-x HF high feature soft starter

DS1e-x HF high feature direct-online starter

5
TM-P15 terminal module for PM-D

Terminal module for standard direct-on-line starter with infeed TM-DS45-S32 PE/N M45-PEN-F terminal block PE/N M45-PEN-S terminal block M65-PEN-F infeed module M65-PEN-S connection module

Terminal module for high feature direct-on-line starter/soft starter without infeed TM-DS65-S31

Terminal module for standard direct-on-line starter without infeed TM-DS45-S31

Terminal module for high feature Terminal module for direct-on-line starter/soft starter TM-xB215-S24-01 brake control module with infeed TM-DS65-S32

Interplay of ET 200S motor starter components

Application
With the ET 200S motor starters, any AC loads can be protected and switched. The communications interface makes them ideal for operation in distributed control cabinets or control enclosures. As the motor starters are completely factory-wired, power control cabinets can be assembled far more quickly and compactly. Configuration is made easier by the fine modular structure. When using the ET 200S motor starters, the list of parts per load feeder is reduced to two main items: The passive terminal module and the motor starter. This makes the ET 200S ideal for modular machine concepts as well. Expansions are easily possible through the subsequent adding of terminal modules. With their modular terminal design (10 mm) the latter also do away with the distribution wiring otherwise required. Through the permanent wiring and the hot swapping function (disconnection and connection during operation) a motor starter can be replaced within seconds if necessary. The motor starters are therefore recommendable in particular for applications with special demands on availability. The possibility of expanding the motor starters with brake control modules xB1-xB4 means that motors with 24 V DC brakes (xB1, xB3) as well as motors with 500 V DC brakes (xB2, xB4) can be controlled. The 24 V DC brakes have an external supply and can be vented independently of the switching state of the motor starter. By contrast the 500 V DC brakes mostly have a direct supply from the terminal board of the motor through a rectifier module and therefore cannot be vented when the motor starter is switched off. These brakes cannot be used in combination with the DSS1e-x motor starter (soft starter). The outputs of the brake control modules can be used alternatively for other purposes, e.g. for controlling DC valves. With two locally acting inputs optionally available on the brake control modules (xB3, xB4) and another two on the control module of the High-Feature motor starter it is possible to realize autonomous special functions which work independently of the bus and the higher-level control system, e.g. as a quick stop on gate valve controls. In parallel with this, the states of these inputs are signaled to the control system.

NSA0_00459

Siemens IK PI 2009

5/105

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S motor starters

SIMATIC ET 200 distributed I/Os

Application (continued)
As the result of the selective protection concept with solid-state overload evaluation and the use of SIRIUS switchgear size S0, additional advantages are realized on the High-Feature motor starters advantages which soon make themselves positively felt particularly in manufacturing processes with high plant stoppage costs: Only two versions up to 7.5 kW All settings can be parameterized by bus Separate overload and short-circuit signals Overload can be acknowledged by remote reset Current unbalance monitoring Stall protection Emergency start function in the event of overload Current value transmission by bus Current limit monitoring Class 10 or 20 can be parameterized Type of coordination "2" (still functional after short-circuit with magnitude of 50 kA) Very high contact endurance Accessories Following accessories are available: DM-V15 distance module The distance module is available for applications with high motor currents or high ambient temperatures involving Standard motor starters. It can be used to the right and left of a DS1-x directonline starter or to the right of an xB1-4 brake module in order to improve heat removal to the side. The distance module is a completely passive module and does not need to be taken into account with regard to the control system during configuration. Details of the distance module can be found in the manual "SIMATIC ET 200S". If you have any queries concerning the use of the distance module, contact Technical Support for Siemens Low-Voltage Controls (fax: ++49(0)911/895-5907). PE/N bridge module PE/N bridge modules are used to bridge gaps in the PE/N bus which are caused, for example, by using brake control modules, PM-D(F) power modules or PM-X connection modules. If a bridge module is used, the supply must not be fed in anew. They are available in widths of 15 and 30 mm. L1/L2/L3 bridge module The L1/L2/L3 bridge modules are used to bridge gaps in the power bus (see above). They are available in widths of 15 and 30 mm.

5/106

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version Standard motor starters with diagnostics, electromechanical, fuseless, expandable with brake control module DS1-x direct-on-line starters Motor rating of induction motor 4-pole at 400 V AC, standard output P in kW < 0.06 0.06 0.09 0.10 0.12 0.18
DS1-x

Order No.

Setting range of the electronic trip unit in A 0.14 ... 0.20 0.18 ... 0.25 0.22 ... 0.32 0.28 ... 0.40 0.35 ... 0.50 0.45 ... 0.63 0.55 ... 0.80 0.70 ... 1.00 0.90 ... 1.25 1.1 ... 1.6 1.4 ... 2.0 1.8 ... 2.5 2.2 ... 3.2 2.8 ... 4.0 3.5 ... 5.0 4.5 ... 6.3 5.5 ... 8.0 7 ... 10 9 ... 12 in A 0.14 ... 0.20 0.18 ... 0.25 0.22 ... 0.32 0.28 ... 0.40 0.35 ... 0.50 0.45 ... 0.63 0.55 ... 0.80 0.70 ... 1.00 0.90 ... 1.25 1.1 ... 1.6 1.4 ... 2.0 1.8 ... 2.5 2.2 ... 3.2 2.8 ... 4.0 3.5 ... 5.0 4.5 ... 6.3 5.5 ... 8.0 7 ... 10 9 ... 12 3RK1 301-0BB00-1AA2 3RK1 301-0CB00-1AA2 3RK1 301-0DB00-1AA2 3RK1 301-0EB00-1AA2 3RK1 301-0FB00-1AA2 3RK1 301-0GB00-1AA2 3RK1 301-0HB00-1AA2 3RK1 301-0JB00-1AA2 3RK1 301-0KB00-1AA2 3RK1 301-1AB00-1AA2 3RK1 301-1BB00-1AA2 3RK1 301-1CB00-1AA2 3RK1 301-1DB00-1AA2 3RK1 301-1EB00-1AA2 3RK1 301-1FB00-1AA2 3RK1 301-1GB00-1AA2 3RK1 301-1HB00-1AA2 3RK1 301-1JB00-1AA2 3RK1 301-1KB00-1AA2 3RK1 301-0BB00-0AA2 3RK1 301-0CB00-0AA2 3RK1 301-0DB00-0AA2 3RK1 301-0EB00-0AA2 3RK1 301-0FB00-0AA2 3RK1 301-0GB00-0AA2 3RK1 301-0HB00-0AA2 3RK1 301-0JB00-0AA2 3RK1 301-0KB00-0AA2 3RK1 301-1AB00-0AA2 3RK1 301-1BB00-0AA2 3RK1 301-1CB00-0AA2 3RK1 301-1DB00-0AA2 3RK1 301-1EB00-0AA2 3RK1 301-1FB00-0AA2 3RK1 301-1GB00-0AA2 3RK1 301-1HB00-0AA2 3RK1 301-1JB00-0AA2 3RK1 301-1KB00-0AA2

0.21 0.25 0.37 0.55 0.75 0.90 1.1 1.5 1.9 2.2 3.0 4.0 5.5 RS1-x reversing starters in kW < 0.06 0.06 0.09 0.10 0.12 0.18

RS1-x

0.21 0.25 0.37 0.55 0.75 0.90 1.1 1.5 1.9 2.2 3.0 4.0 5.5

Siemens IK PI 2009

5/107

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data (continued)


Version DS1e-x direct-on-line starters with switch interface Setting range of the electronic trip unit in A 0.3 ... 3 2.4 ... 8 2.4 ... 16 RS1e-x reversing starters Setting range of the electronic trip unit in A
DS1e-x

Order No.

3RK1 301-0AB10-0AA4 3RK1 301-0BB10-0AA4 3RK1 301-0CB10-0AA4

0.3 ... 3 2.4 ... 8 2.4 ... 16 DSS1e-x soft starters Setting range of the electronic trip unit in A 0.3 ... 3 2.4 ... 8 2.4 ... 16

3RK1 301-0AB10-1AA4 3RK1 301-0BB10-1AA4 3RK1 301-0CB10-1AA4

3RK1 301-0AB20-0AA4 3RK1 301-0BB20-0AA4 3RK1 301-0CB20-0AA4

Accessories for motor starters, Standard


Control kit for manually operating the contactor contacts during start-up and servicing (one set contains five control kits)
3RK1 903-0CA00

3RK1 903-0CA00

Control unit for direct contactor control (manual control) 24 V DC

3RK1 903-0CG00

3RK1 903-0CG00

DM-V15 distance module for DS1-x direct-on-line starters with high temperature or high current loading 15 mm wide

3RK1 903-0CD00

3RK1 903-0CD00

Accessories for High-Feature motor starters


Control modules 2DI 24 V DC COM Digital input module with 2 inputs for local motor starter functions for mounting onto the front of motor starters Operational voltage 24 V DC (supplied from U1), short-circuit resistant, floating contact with serial interface for connecting Switch ES Connected using LOGO!-PC cable, max. cable length (out and back) 50 m LOGO! PC cable for connecting the High-Feature motor starter with Switch ES interface to a PC
3RK1 903-0CH20

3RK1 903-0CH20

6ED1 057-1AA00-0BA0

Hand-held device for ET 200S High Feature motor starter, (also for ET 200pro and ECOFAST), for local operation. A serial interface cable must be ordered separately.

3RK1 922-3BA00

3RK1 922-3BA00

5/108

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data (continued)


Version Order No.

Accessories for Standard / High-Feature motor starters and frequency converters


M15-PEN bridge module 15 mm wide for bridging a 15 mm module 3RK1 903-0AH00

3RK1 903-0AH00

M30-PEN bridge module 30 mm wide for bridging a 30 mm module

3RK1 903-0AJ00

3RK1 903-0AJ00

M15-L123 bridge module 15 mm wide for bridging a 15 mm module

3RK1 903-0AE00

5
3RK1 903-0AF00

3RK1 903-0AE00

M30-L123 bridge module 30 mm wide for bridging a 30 mm module

3RK1 903-0AF00

3RK1 903-0CB00

Brake control module for motors with mechanical brake xB1 for motor starters and frequency converters 24 V DC/ 4 A xB2 for motor starters and frequency converters 500 V DC/ 0.7 A xB3 for motor starters 24 V DC / 4 A / 2 DI 24 V DC local control with diagnostics with two inputs xB4 for motor starters 500 V DC / 0.7 A / 2 DI 24 V DC local control with diagnostics with two inputs Terminal modules for brake control modules TM-xB15 S24-01 for xB1 or xB2 TM-xB215 S24-01 for xB3 or xB4 EMC filter for frequency converters for achieving EMC Class A the frequency converter is connected upstream to the shared power bus, EMC-compatible design with shielded motor cables required Rated current 25 A Rated current 50 A MMC parameter memory for frequency converters suitable for MMC slot of ICU24/ICU24F control module; other memory cards are not accepted RS232/zero modem cables (5 m) Connection cable for starting up the ET 200S FC frequency converter with the "STARTER" PC tool

3RK1 903-0CB00

3RK1 903-0CC00

3RK1 903-0CE00

3RK1 903-0CF00

3RK1 903-0AG00 3RK1 903-0AG01

6SL3 203-0BE22-5AA0 6SL3 203-0BE25-0AA0 6SL3 254-0AM00-0AA0

6ES7 901-1BF00-0XA0

Siemens IK PI 2009

5/109

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Overview

Benefits
The frequency converter is completely integrated into the ET 200S system and offers all system advantages, such as high availability thanks to the hot swapping function, modular expansion, or reduction of the wiring overhead resulting from the self-assembling terminal module wiring. With self-assembling 50 A power bus, i.e. the load voltage is only supplied once for a group of frequency converters Comprehensive diagnostics facilities for high availability Input for motor encoder for precise speed control Input for PTC/KTY encoder for comprehensive motor protection Slot for optional memory card (MMC) to save the parameter settings for fast replacement of modules without tools All common control modes are available: Frequency control, sensorless vector control or torque control, closed-loop control with motor encoder Parameters are assigned using STARTER, the graphical parameterizing tool for Siemens drives, either via the connected fieldbus or via a point-to-point connection. Note: Access to the frequency converter via the bus is not possible using STARTER if there is a CPU between the PC and the frequency converter. This also applies to CPU IM 151-7. Active braking is possible without additional overhead. The line-commutated energy recovery of the frequency converter for the power supply network means that brake chopper modules or pulsed resistors are superfluous.

Components of the ET 200S FC frequency converter

Application
New application possibilities are opened up for the ET 200S system where continuous control of the speed of asynchronous motors is required. The frequency converter handles frequency control and vector control for more complex drive tasks. In addition, the converter also supports torque control for conveyor applications, winding and unwinding drives, as well as hoisting gear. Together with a motor encoder, the range extends up to closed-loop controls for exact control of speeds and torques. The advantages of line-commutated power regeneration are primarily evident in continuous regenerative operation. Examples include unwinding units, lowering of loads with hoisting gear, or electric braking of large centrifugal masses. Together with an intelligent header module (IM 151 CPU) and the ET 200S FC frequency converter, the I/O station is expanded to become a complete automation solution for machine modules and plant sections.

5/110

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Design
Accessories The following accessories are available: The labeling strips and color coding labels of the ET 200S system can also be used for the frequency converter. Jumper block L1/L2/L3 The jumper blocks L1/L2/L3 are used to bridge a gap in the power bus. 15 mm wide jumper blocks are used to bridge the control unit of the subsequent frequency converter. If a Brake Control Module is connected, a 30 mm wide jumper block is required in order to pass on the power bus via the Brake Control Module and ICU24 to the subsequent IPM25 converter power module. Jumper block PE/N The jumper blocks PE/N are used to bridge a gap in the PE/N bus, e.g. caused by use of a Brake Control Module, a PM-D(F) power module or the control unit of the frequency converter. EMC filter An EMC filter must be externally connected to the supply of the power bus in order to achieve EMC Class A (according to EN 55011). Shielded motor cables must be used in addition. It must be ensured that the shield is connected correctly. The terminal modules for the converter power module of the frequency converter are equipped for this with an integral shield connecting element. Within the ET 200S system, several frequency converters can be supplied with 400 V over a common power bus. The EMC filter is connected up-circuit of the power bus. The filters are designed for a maximum effective length of 350 m shielded cable. The effective cable length is the combined length of all motor cables of the frequency converter on the common 400 V power bus. The two EMC filters of the ET 200S FC are designed as group filters for more than one frequency converter and have the following properties:
EMC filter Type 6SL3203-0BE22-5AA0 6SL3203-0BE25-0AA0 Rated current 25 A 50 A Maximum cable length 350 m 350 m Conductor cross-section 4 mm 10 mm

Design of an ET 200S station with two ET 200S FC frequency converters (only terminal modules on the right)

The ET 200S FC consists of the following components: ICU24 control unit IPM25 converter power module Terminal modules to accommodate control unit and converter power module Following insertion of the modules, the control unit and the converter power module of the frequency converter are interconnected. The PMD power module provides the power supply for one or more control units.

Siemens IK PI 2009

5/111

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Design (continued)
The use of output reactors or LC filters on the converter output does not affect the maximum cable length for the EMC filter. Output reactors and LC filters for longer cable lengths Without additional components on the converter output, the maximum length of motor cables on the SIMATIC ET 200S FC frequency converter is 50 m (shielded cable) or 100 m (unshielded). Longer cables are possible when output reactors of LC filters are used: To reduce the capacitive equalizing currents and dv/dt for motor cables, output reactors are provided. Consequently when output reactors are used, the maximum permissible cable lengths between the motor and converter are:
IPM25 converter power module Output reactor Type Max. permissible motor cable lengths (shielded/unshielded) for a line voltage of 380 V -10 % to 400 V 0.75 kW 6SE64003TC00-4AD2 6SE64003TC01-0BD3 150 m/225 m 150 m/225 m 401 V to 480 V+10 % 100 m/150 m 100 m/150 m

Function
The ET 200S FC is capable of dynamic control procedures such as sensorless vector control or torque control. Where particular speed accuracy and dynamic response requirements exist, a motor encoder can be connected to the control module. The ET 200S FC is operated without a line reactor. A PTC or KTY encoder can be connected to the control module to evaluate the motor temperature. Accessories The following accessories are available: MMC parameter memory If required, the complete parameter settings of the frequency converter can be saved on a memory card (MMC). When servicing, the plant is immediately ready for use again after replacing the frequency converter and inserting the memory card.

2.2 kW and 4.0 kW

The LC filter limits the rate of rise of voltage and the capacitive charge/discharge currents which occur with converter operation. This means that considerably longer motor cables can be used for operation with LC filters. The service life of the motor is as long as for direct mains operation. It is therefore not necessary to use an output reactor. When LC filters are used, the maximum permissible cable lengths between the motor and converter are:
IPM25 converter power module LC filter Type Max. permissible motor cable lengths (shielded/unshielded) for a line voltage of 380 V to 480 V -10 % +10 % 200 m/300 m 200 m/300 m

0.75 kW 2.2 kW and 4.0 kW

6SE64003TD00-4AD0 6SE64003TD01-0BD0

When an output reactor or LC filter is used, it is important to note the following during assembly and start-up: The output reactors and LC filters must be mounted alongside or below the ET 200S station. Vertical alignment is important to ensure adequate cooling. The connecting cable to the converter must be pre-assembled for all components and shortened to a length of approximately 30 cm - the shield of the motor cable must be attached to the output reactor or the LC filter. The pulse frequency of the converter must be reduced to 4 kHz (the factory setting is 8 kHz). In addition, when an LC filter is used, the converter must be operated in V/f mode. Shield clamps To connect the shield of motor cables Grounding terminal To ground the 3 x 10 mm busbar for the shield connection Busbar 3 x 10 mm To accommodate the shield clamps and the grounding terminal Brake Control Module xB1 or xB2 to control an external electromechanical brake

5/112

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Technical specifications
Control unit ICU24 Selection features Integral safety functions according to Category 3 of EN 954-1 or according to SIL2 of IEC 61508 Output Rated input current (at 50 C ambient temperature) Rated output current (at 50 C ambient temperature) Mounting dimensions (W x H x D) in mm (including terminal module) Electrical data Line voltage Line frequency Overload capability Output frequency Pulse frequency Standard short circuit current rating SCCR (Short Circuit Current Rating) 1) Skipped frequency range Converter efficiency Typical power loss at 420 V input voltage 2) and motor with rated load (motor and regenerative mode) Typical power loss at 420 V input voltage 2) and motor during no-load operation, 50 Hz Interfaces 380 V to 480 V 3 AC +10 % / -10 % 47 Hz to 63 Hz Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s Overload current 2 x rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s 0 Hz to 650 Hz 8 kHz (standard), 2 kHz to 16 kHz (in 2 kHz steps) 10 kA Converter power modules IPM25, FS A Frame size A IPM25, FS B Frame size B

15 x 220 x 156

0.75 kW 1.9 A 2.1 A 65 x 290 x 156

2.2 kW 5.7 A 5.9 A 130 x 290 x 156

4.0 kW 9.6 A 10.2 A

1, programmable 96 % at rated load of the motor 10 W 40 W (Pulse frequency 8 kHz) 65 W (Pulse frequency 16 kHz) 30 W (Pulse frequency 4 kHz) 10 W 35 W (Pulse frequency 8 kHz) 110 W 140 W 80 W 70 W 160 W 200 W 130 W 110 W

Connection to PROFIBUS or PROFINET over the ET 200 S backplane bus RS232 interface with USS protocol for commissioning on the PC using the STARTER commissioning software Slot for an optional memory card (MMC) for uploading or downloading parameter settings PTC/KTY84 interface for motor temperature monitoring Speed sensor interface (Sub-D connector) for unipolar HTL incremental position encoder V/f control linear (M~n) with/without flux current control (FCC), quadratic (M~n2) or parameterizable Vector control with or without encoder Torque control Jogging mode, free function blocks (FFB), positioning deceleration ramp, automatic restart following interruption due to power failure, bumpless connection of converter to rotating motor Regenerative braking operation without brake chopper and pulsed resistor Control of an electrical holding brake via an optional Brake Control Module Undervoltage, overvoltage, ground faults, short circuits, stall prevention, thermal motor protection I2t, converter overtemperature, motor blocking protection Low-voltage asynchronous motors Motor cable lengths: max. 50 m (shielded) max. 100 m (unshielded) If an output reactor or an LC filter is used, longer cable lengths are possible IP20 With vertical design of station With horizontal design of station -10 C to + 40 C -10 C to + 50 C/to +60 C with derating

Functions Control method

Operating functions Braking functions Protection features for Connectable motors

Mechanical data Degree of protection Operating temperature Standards Compliance with standards
1) 2)

UL, cUL, CE, c-tick, according to low-voltage directive 73/23/EEC, EMC directive 89/336/EEC

Applies to industrial industrial control cabinet installations according to NEC Article 409 / UL 508A. The power loss varies according to the input voltage.

Additional information can be found in the Internet under: http://www.support.automation.siemens.com/ ww/view/en/23995621


Siemens IK PI 2009

5/113

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Derating data Pulse frequency
Output kW 0.75 2.2 4.0 Rated output current in A at a pulse frequency of 2 kHz 2.1 5.9 10.2 4 kHz 2.1 5.9 10.2 6 kHz 2.1 5.9 10.2 8 kHz 2.1 5.9 10.2 10 kHz 1.05 5.3 5.1 12 kHz 1.05 5.3 5.1 14 kHz 1.05 5,3 5.1 16 kHz 1.05 5.3 5.1

The current data apply to an ambient temperature of 50 C unless specified otherwise.

Selection and Ordering Data


Version ICU24 control unit Control modes: V/f, FCC, SLVC, VC with encoder, torque control Motor encoder input: HTL unipolar Motor temperature input: PTC/KTY Order No. 6SL3244-0SA00-1AA1

IPM25 converter power module 380 V 480 V 3 AC +10/-10 % 47 Hz - 63 Hz Overload: 150 % 60 s 200 % 3 s Power: 0.75 kW

6SL3225-0SE17-5UA1

IPM25 converter power module 380 V 480 V 3 AC +10/-10 % 47 Hz - 63 Hz Overload: 150 % 60 s 200 % 3 s Power: 2.2 kW 4.0 kW

6SL3225-0SE22-2UA1 6SL3225-0SE24-0UA1

5/114

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions
156 137.5 11.7
Clearance required due to heat build-up, min. 35 mm 79.6 64.8

Clea rance required due to heat build-up, min. 35 mm

156 144.5 124

21 15

66

100 194.6 220.5

100

Mounting rail 35 x 7.5 mm

66

Mounting rail 35 x 7.5 mm

G_D011_EN_00056a

Clearance G_D011_EN_00054a required due to heat build-up, min. 35 mm

333

250.5 Wire range

72 161

Clea rance required due to heat build-up, min. 35 mm

Clearance required due to heat build-up, min. 35 mm

31

Integrated screen support Terminal block PE/N (accessory)

Integrated screen support

Terminal block PE/N (accessory)

Motor connections

Supply terminal for power bus

ICU24 control unit

IPM25 converter power module, 0.75 kW

Clea rance required due to heat build-up, min. 35 mm

156 137.5 11.7

144.8 130

66

Mounting rail 35 x 7.5 mm

100

333

250.5
Motor connections Supply terminal for power bus Terminal block PE/N (accesso ry) Integrated screen suppo rt

Clea rance G_D011_EN_00055a required due to heat build-up, min. 35 mm

Clea rance 31 required due to heat build-up, min. 35 mm

Integrated screen suppo rt

Terminal block PE/N (accesso ry)

IPM25 converter power module, 2.2 kW and 4.0 kW

Wire range

Siemens IK PI 2009

5/115

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions (continued)

24

200

75.5 56

187 200
G_D011_EN_00062

120 141.5

1.5

Terminals 10 mm2 Tightening torque of screw 1.2 ... 1.5 Nm PE M6 x 24 Tightening torque 4.8 0.2 Nm

255 265

4.5

35 60

110

Fixing with M4 bolts

G_D011_EN_00084

EMC filter, 50 A

Output reactor for IPM25 FS A

24

200

G_D011_En_00063

120 141.5

150 120

200 213
1.5

255 265
G_D011_EN_00085

4.5

35 60

PE M6 x 24 Tightening torque 4.8 0.2 Nm

Terminals 4 mm2 Tightening torque of screw 0.5 ... 0.6 Nm

Fixing with M4 bolts

EMC filter, 25 A

Output reactor for IPM25 FS B

5/116

Siemens IK PI 2009

70

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


ET 200S FC frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions (continued)

75.5 56

287 300 334

110

5
Fixing with M4 bolts
G_D011_EN_00086

LC filter for IPM25 FS A

150 138

280 293 340

100

Fixing with M4 bolts

LC filter for IPM25 FS B

G_D011_EN_00087

120

Siemens IK PI 2009

5/117

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


Power modules for ET 200S motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Overview

Application
PM-D power modules are used for monitoring the two 24 V DC auxiliary voltages for the group of motor starters following on the right or for supplying power to the group of frequency converters following on the right. The voltage is fed in through TM-D terminal modules to the self-assembling potential bars. A voltage failure is signaled through PROFIBUS diagnostics to the higher-level master. Additional LEDs inform locally about the status of the auxiliary voltages. The separation of auxiliary voltages for signal checkback and power section actuation enables the entire group to be shut down while maintaining the diagnostics capability.

For supplying and monitoring the auxiliary voltages for motor starters and frequency converters Disconnection of a complete group of motor starters is possible without any additional outlay (safety category 1 according to EN 954-1) For plugging onto TM-P15 terminal module

Selection and ordering data


Version PM-D power modules for 24 V DC with diagnostics Order No. 3RK1 903-0BA00

3RK1 903-0BA00

Accessories
Color coding plates 6 x 200 color coding plates for terminal modules One set contains 10 strips of 20 color coding plates per color White Yellow Yellow and green Red Blue Brown 6ES7 193-4LA10-0AA0 6ES7 193-4LB10-0AA0 6ES7 193-4LC10-0AA0 6ES7 193-4LD10-0AA0 6ES7 193-4LF10-0AA0 6ES7 193-4LG10-0AA0

5/118

Siemens IK PI 2009

Siemens AG 2008

ET 200S Motor Starter and Frequency Converter


Power modules for ET 200S motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Dimensions
117,5 8,2 15

100

66

PM-D

7
194,6 195,6

TM-P15

100

101,9

PM-D power module and TM-P15 terminal module

NSA00305

Siemens IK PI 2009

5/119

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Introduction

SIMATIC ET 200 distributed I/Os

Overview

The ET 200S Safety motor starters Solutions comprise: Safety modules Standard motor starters High-Feature motor starters Failsafe motor starters With the ET 200S Safety motor starters Solutions there is no complicated and hence cost-intensive configuring and wiring outlay compared to the conventional safety technology. The ET 200S Safety motor starter Solutions are designed for Category 4 according to EN 954-1 or SIL 3 IEC 61508. They enable the use of safety-oriented direct-on-line starters or reversing starters in the SIMATIC ET 200S distributed peripherals system on PROFINET or PROFIBUS. The fine modular architecture of the system permits optimum imaging of machine or plant applications. Within an ET 200S station the Safety motor starter Solutions can also be combined with Standard motor starters or High-Feature motor starters without safety functions or the SIMATIC ET 200S FC frequency converter up to max. 4 kW up to Category 3 according to EN 954-1 or SIL 2 according to IEC 61508. Standard and High Feature ET 200S motor starters can be found on page page 104 onwards. The "SIMATIC ET 200 Configurator" software can be found in Catalog CA 01 on CD or DVD. You can also download the "SIMATIC ET 200 Configurator" software from the Internet under: http://www.siemens.com/sirius-starting http://www.siemens.com/ET200S Note: for safety characteristics, see Catalog LV 1

Frequency converter ET 200S FC Failsafe

Failsafe frequency converter For the continuous speed control of asynchronous motors Comprising modules for the ICU24F control module and IPM25 power section up to 4.0 kW Hot swapping of control module and power section is permissible Operation without line commutation reactor Active braking with line-commutated power recovery Can be combined with brake control module for actuating an electromechanical holding brake To achieve EMC class A (according to EN 55011), connection of an EMC filter upstream from the power bus The ET 200S FC fail-safe version provides extensive integrated safety functions (certified according to EN 954-1, Category 3 or IEC 61508, SIL 2) Safe torque off torque (STO) to guard against any active movement of the operating mechanism Safely limited speed (SLS) to guard against danger from movements caused when a limit speed is exceeded Safe stop 1 (SS1, Safe Stop 1) for continuous monitoring of a safe brake ramp Both the "Safe Stop 1" function and the "Safely Limited Speed" function operate without motor sensor or encoder; the implementation cost is minimal. Existing systems in particular can be retrofitted with safety technology without the motor or mechanics having to be modified. The "Safely Limited Speed" and "Safe Stop 1" safety functions are certified for asynchronous motors without sensors these safety functions are not approved for drawing loads such as lifting devices and unwinders.

Application
The ET 200S Safety motor starter Solutions are preferred in all production and process automation fields in which the enhancement of plant availability and flexibility plays a key role. Safety motor starters Solutions local are preferred from the safety technology point of view for locally restricted safety applications. These motor starters are not dependent on a safe control system. Safety motor starters Solutions PROFIsafe are often found by contrast in safety applications of the more complex type that are interlinked. In this case a safe control system is used with the bus systems PROFINET or PROFIBUS with the PROFIsafe profile.

5/120

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S Failsafe motor starters

SIMATIC ET 200 distributed I/Os

Overview

Benefits
Advantages over conventional safety technology Significant savings in components (less hardware) Less mounting and installation work Motor starters are failsafe and offer high availability

Application
Use The Failsafe motor starter is predestined for use in combination with PROFIsafe (see figure ET 200S Safety Motor Starter Solution PROFIsafe page 137). Another field of application is in combination with ASIsafe or safety relays (see example 2 on page 132 Failsafe Motor Starters with ASIsafe and 3TK28).

The Failsafe motor starter has been developed on the basis of the High-Feature motor starter. It differs in that, in addition to a motor starter protector and contactor assembly, a safe solidstate evaluation circuit is installed for error detection purposes which makes the motor starter failsafe. If the contactor to be switched fails in an EMERGENCY-STOP case, the evaluation electronics detect a fault and open the motor starter protector in the motor starter through a shunt trip unit in a failsafe manner. The second redundant shutdown component is therefore no longer a main contactor, as is generally the case, but the motor starter protector installed in the motor. All functions of the High-Feature starter are already integrated The new failsafe motor starters are characterized by easy, space-saving assembly as well as minimal wiring outlay. Like the High-Feature starters, the Failsafe motor starters have a switching capacity of up to 7.5 kW (16 A) which is achieved with just two motor starter versions. Another important feature is the high availability due to the high short-circuit strength (type of coordination "2").

Siemens IK PI 2009

5/121

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S Failsafe motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version ET 200S Failsafe motor starters F-DS1e-x direct-on-line starters Failsafe direct-on-line starters up to 7.5 kW at AC 400 V Mechanically switching Solid-state UE protection 0.3 ... 3 A 2.4 ... 8 A
F-DS1e-x direct-on-line starters

Order No.

3RK1 301-0AB13-0AA4 3RK1 301-0BB13-0AA4 3RK1 301-0CB13-0AA4

2.4 ... 16 A F-RS1e-x reversing starters Failsafe reversing starters up to 7.5 kW at AC 400 V Mechanically switching Solid-state UE protection, fuseless 0.3 ... 3 A 2.4 ... 8 A 2.4 ... 16 A

3RK1 301-0AB13-1AA4 3RK1 301-0BB13-1AA4 3RK1 301-0CB13-1AA4

Components for Failsafe motor starters TM-FDS65-S32-01/S31-01 terminal module for F-DS1e-x direct-on-line starters with coding With incoming energy bus connection (TM-FDS65-S32-01) Without incoming energy bus connection (TM-FDS65-S31-01) TM-FRS130-S32-01/S31-01 terminal module for F-RS1e-x reversing starters with coding With incoming energy bus connection (TM-FRS130-S32-01) Without incoming energy bus connection (TM-FRS130-S31-01) PE/N M65-PEN-F terminal block with incoming power bus connection, with caps M65-PEN-S terminal block without incoming power bus connection 3RK1 903-3AD00 3RK1 903-3AD10 3RK1 903-2AC00 3RK1 903-3AC00 3RK1 903-3AC10

3RK1 903-2AC10

5/122

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Overview

Benefits
Frequency converters with integrated safety functions "Safe Torque OFF", "Safely Limited Speed" and "Safe Stop 1". The frequency converter is completely integrated into the ET 200S system and offers all system advantages, such as high availability thanks to the hot swapping function, modular expansion, or reduction of the wiring overhead resulting from the self-assembling terminal module wiring. With self-assembling 50 A power bus, i.e. the load voltage is only supplied once for a group of frequency converters Comprehensive diagnostics facilities for high availability Input for motor encoder for precise speed control Input for PTC/KTY encoder for comprehensive motor protection Slot for optional memory card (MMC) to save the parameter settings for fast replacement of modules without tools All common control modes are available: Frequency control, sensor-less vector control or torque control, closed-loop control with motor encoder Parameters are assigned using STARTER, the graphical parameterizing tool for Siemens drives, either via the connected fieldbus or via a point-to-point connection. Note: Access to the frequency converter via the bus is not possible using STARTER if there is a CPU between the PC and the frequency converter. This also applies to CPU IM 151-7. Active braking is possible without additional overhead. The line-commutated energy recovery of the frequency converter for the power supply network means that brake chopper modules or pulsed resistors are superfluous. The "safe standstill" is completely electronic and therefore without contacts. This provides reliable and extremely short response times. Unique is that the "Safely Limited Speed" and the "Safe Stop 1" do not require a motor encoder or other encoder. These functions can therefore be implemented with minimum overhead.

Components of the ET 200S FC fail-safe frequency converter

Application
New application possibilities are opened up for the ET 200S system where continuous control of the speed of asynchronous motors is required. The frequency converter handles frequency control and vector control for more complex drive tasks. In addition, the converter also supports torque control for conveyor applications, winding and unwinding drives, as well as hoisting gear. Together with a motor encoder, the range extends up to closedloop controls for exact control of speeds and torques. The advantages of line-commutated power regeneration are primarily evident in continuous regenerative operation. Examples include unwinding units, lowering of loads with hoisting gear, or electric braking of large centrifugal masses. Together with an intelligent header module (IM 151 CPU) and the ET 200S FC frequency converter, the I/O station is expanded to become a complete automation solution for machine modules and plant sections. The integral safety functions significantly reduce the overhead for drive solutions in plant sections where there is a hazard potential. Monitoring of the safely reduced speed in sensor-less standard asynchronous motors is unique in drive engineering.

Siemens IK PI 2009

5/123

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Design
Accessories The following accessories are available: The labeling strips and color coding labels of the ET 200S system can also be used for the frequency converter. Jumper block L1/L2/L3 The jumper blocks L1/L2/L3 are used to bridge a gap in the power bus. 15 mm wide jumper blocks are used to bridge the control unit of the subsequent frequency converter. If a Brake Control Module is connected, a 30 mm wide jumper block is required in order to pass on the power bus via the Brake Control Module and ICU24 to the subsequent IPM25 converter power module. Jumper block PE/N The jumper blocks PE/N are used to bridge a gap in the PE/N bus, e.g. caused by use of a Brake Control Module, a PM-D(F) power module or the control unit of the frequency converter. EMC filter An EMC filter must be externally connected to the supply of the power bus in order to achieve EMC Class A (according to EN 55011). Shielded motor cables must be used in addition. It must be ensured that the shield is connected correctly. The terminal modules for the converter power module of the frequency converter are equipped with an integral shield connection element. Within the ET 200S system, several frequency converters can be supplied over a common power bus with 400 V. The EMC filter is connected up-circuit of the power bus. The filters are designed for a maximum effective length of 350 m shielded cable. The effective cable length is the combined length of all motor cables of the frequency converter on the common 400 V power bus. The two EMC filters of the ET 200S FC are designed as group filters for more than one frequency converter and have the following properties:
EMC filter Type 6SL3203-0BE22-5AA0 6SL3203-0BE25-0AA0 Rated current 25 A 50 A Maximum cable length 350 m 350 m Conductor cross-section 4 mm 10 mm

Design of an ET 200S station with two ET 200S FC fail-safe frequency converters (on the right only terminal modules)

The ET 200S FC consists of the following components: ICU24F control unit (F = with integral safety technology) IPM25 converter power module Terminal modules to accommodate control unit and converter power module Following insertion of the modules, the control unit and the converter power module of the frequency converter are interconnected. The PM-D F PROFIsafe or PM-D F X1 power modules provide the power supply for one or more control units.

The use of output reactors or LC filters on the converter output does not affect the maximum cable length for the EMC filter. Output reactors and LC filters for longer cable lengths Without additional components on the converter output, the maximum length of motor cables on the SIMATIC ET 200S FC frequency converter is 50 m (shielded cable) or 100 m (unshielded). Longer cables are possible when output reactors or LC filters are used: To reduce the capacitive equalizing currents and dv/dt for motor cables, output reactors are provided. Consequently when output reactors are used, the maximum permissible cable lengths between the motor and converter are:
IPM25 converter power module Output reactor Type Max. permissible motor cable lengths (shielded/unshielded) for a line voltage of 380 V -10 % to 400 V 0.75 kW 2.2 kW and 4.0 kW 6SE64003TC00-4AD2 6SE64003TC01-0BD3 150 m/225 m 150 m/225 m 401 V to 480 V+10 % 100 m/150 m 100 m/150 m

5/124

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Design (continued)
The LC filter limits the rate of rise of voltage and the capacitive charge/discharge currents which occur with converter operation. This means that considerably longer motor cables can be used for operation with LC filters. The service life of the motor is as long as for direct mains operation. It is therefore not necessary to use an output reactor. When LC filters are used, the maximum permissible cable lengths between the motor and converter are:
IPM25 converter power module LC filter Type Max. permissible motor cable lengths (shielded/unshielded) for a line voltage of 380 V to 480 V -10 % +10 % 200 m/300 m 200 m/300 m

Function
The ET 200S FC is capable of dynamic control procedures such as sensorless vector control or torque control. Where particular speed accuracy and dynamic response requirements exist, a motor encoder can be connected to the control module. The ET 200S FC is operated without a line reactor. A PTC or KTY encoder in the motor can be evaluated by the control module to evaluate the motor temperature. Integral safety functions are selected via the switch-off modules of a series-connected PM-D F: Safe Torque Off (STO) to protect against active movement of the drive Safely Limited Speed (SLS) to protect against dangerous movements due to exceeded limit speeds. Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp Neither of the functions "Safe Stop 1" or "Safely Limited Speed" requires a motor encoder or other encoder; the implementation cost is minimal. Existing plants in particular can be updated with safety technology without the need to change the motor or mechanical system. The safety functions "Safely Limited Speed" and "Safe Stop 1" are certified for induction motors without encoders these safety functions are not permitted for pullthrough loads as in the case of lifting gear and winders. The safety functions of the ET 200S FC are certified according to Category 3 of EN 954-1 and to SIL 2 of IEC 61508. Accessories The following accessories are available: MMC parameter memory If required, the complete parameter settings of the frequency converter can be saved on a memory card (MMC). When servicing, the plant is immediately ready for use again after replacing the frequency converter and inserting the memory card.

0.75 kW 2.2 kW and 4.0 kW

6SE64003TD00-4AD0 6SE64003TD01-0BD0

When an output reactor or LC filter is used, it is important to note the following during assembly and start-up: The output reactors and LC filters must be mounted alongside or below the ET 200S station. Vertical alignment is important to ensure adequate cooling. The connecting cable to the converter must be pre-assembled for all components and shortened to a length of approximately 30 cm - the shield of the motor cable must be attached to the output reactor or the LC filter. The pulse frequency of the converter must be reduced to 4 kHz (the factory setting is 8 kHz). In addition, when an LC filter is used, the converter must be operated in V/f mode. Shield clamps To connect the shield of motor cables Grounding terminal To ground the 3 x 10 mm busbar for the shield connection Busbar 3 x 10 mm To accommodate the shield clamps and the grounding terminal Brake Control Module xB1 or xB2 to control an external electromechanical brake

Siemens IK PI 2009

5/125

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Technical specifications
Control unit ICU24F Selection features Integral safety functions according to Category 3 of EN 954-1 or according to SIL2 of IEC 61508 Output Rated input current (at 50 C ambient temperature) Rated output current (at 50 C ambient temperature) Mounting dimensions (W x H x D) in mm (including terminal module) Electrical data Line voltage Line frequency Overload capability Output frequency Pulse frequency 380 V to 480 V 3 AC + 10 %/-10 % 47 Hz to 63 Hz Overload current 1.5 x rated output current (i.e. 150 % overload) for 60 s, cycle time 300 s Overload current 2 x rated output current (i.e. 200 % overload) for 3 s, cycle time 300 s 0 Hz to 650 Hz 8 kHz (standard), 2 kHz to 16 kHz (in 2 kHz steps) Safe Torque Off (STO) Safely Limited Speed (SLS)1) Safe Stop 1 (SS1) 1) 15 x 220 x 156 Converter Power Modules IPM25, FS A Frame size A IPM25, FS B Frame size B

0.75 kW 1.9 A 2.1 A 65 x 290 x 156

2.2 kW 5.7 A 5.9 A 130 x 290 x 156

4.0 kW 9.6 A 10.2 A

Standard short circuit current rating 10 kA SCCR (Short Circuit Current Rating)2) Skipped frequency range Converter efficiency Typical power loss at 420 V input voltage 3) and motor with rated load (motor and regenerative mode) Typical power loss at 420 V input voltage 3) and motor during no-load operation, 50 Hz Interfaces 1, programmable 96 % at rated load of the motor 10 W 40 W (Pulse frequency 8 kHz) 65 W (Pulse frequency 16 kHz) 30 W (Pulse frequency 4 kHz) 35 W (Pulse frequency 8 kHz) 110 W 140 W 80 W 70 W 160 W 200 W 130 W 110 W

10 W

Connection to PROFIBUS or PROFINET over the ET 200S backplane bus RS232 interface with USS protocol for commissioning on the PC using the STARTER commissioning software Activation of the integrated safety functions via PROFIsafe (PM-D F PROFIsafe) or terminals (PM-D F X1) Slot for an optional memory card (MMC) for uploading or downloading parameter settings PTC/KTY84 interface (Sub-D connector) for motor temperature monitoring Speed sensor interface (Sub-D connector) for unipolar HTL incremental position encoder V/f control linear (M~n) with/without flux current control (FCC), quadratic (M~n2) or parameterizable Vector control with or without encoder Torque control Jogging mode, free function blocks (FFB), positioning deceleration ramp, automatic restart following interruption due to power failure, bumpless connection of converter to rotating motor Regenerative braking operation without brake chopper and pulse resistor Control of an electromechanical holding brake via an optional Brake Control Module Undervoltage, overvoltage, ground faults, short circuits, stall prevention, motor thermal protection (I2t, or sensor) inverter overtemperature, motor blocking protection Low-voltage asynchronous motors Motor cable lengths: max. 50 m (shielded) max. 100 m (unshielded) If an output reactor or an LC filter is used, longer cable lengths are possible IP20 With vertical design of station With horizontal design of station -10 C to +40 C -10 C to +50 C/to +60 C with derating

Functions Open-loop/closed-loop control procedure Operating functions Braking functions Protective functions Connectable motors

Mechanical data Degree of protection Operating temperature

Standards Compliance with standards


1)

UL, cUL, CE, c-tick, low-voltage directive 73/23/EEC, EMC directive 89/336/EEC
2)

The safety functions "Safely Limited Speed" and "Safe Stop 1" are certified for asynchronous motors without encoders - these safety functions are not permitted for pull-through loads as in the case of lifting gear and winders.

3)

Applies to industrial control cabinet installations according to NEC Article 409 / UL 508A. Additional information can be found in the Internet under: http://www.support.automation.siemens.com/ww/view/en/23995621 The power loss varies according to the input voltage.

5/126

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Derating data Pulse frequency
Output kW 0.75 2.2 4.0 Rated output current in A at a pulse frequency of 2 kHz 2.1 5.9 10.2 4 kHz 2.1 5.9 10.2 6 kHz 2.1 5.9 10.2 8 kHz 2.1 5.9 10.2 10 kHz 1.05 5.3 5.1 12 kHz 1.05 5.3 5.1 14 kHz 1.05 5.3 5.1 16 kHz 1.05 5.3 5.1

The current data apply to an ambient temperature of 50 C unless specified otherwise.

Selection and Ordering Data


Version ICU24F control unit Control modes: V/f, FCC, SLVC, VC with encoder, torque control Motor encoder input: HTL unipolar Motor temperature input: PTC/KTY Integrated safety functions Order No. 6SL3244-0SA01-1AA1

IPM25 converter power module 380 V 480 V 3 AC +10/-10 % 47 Hz 63 Hz Overload: 150 % 60 s 200 % 3 s Power: 0.75 kW

6SL3225-0SE17-5UA1

IPM25 converter power module 380 V 480 V 3 AC +10/-10 % 47 Hz 63 Hz Overload: 150 % 60 s 200 % 3 s Power: 2.2 kW 4.0 kW

6SL3225-0SE22-2UA1 6SL3225-0SE24-0UA1

Siemens IK PI 2009

5/127

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions
156 137.5 11.7
Clearance required due to heat build-up, min. 35 mm 79.6 64.8

156 144.5 124

Clea rance required due to heat build-up, min. 35 mm

21 15

66

100 194.6 220.5

66

100

Mounting rail 35 x 7.5 mm

Mounting rail 35 x 7.5 mm

G_D011_EN_00056a

Clearance G_D011_EN_00054a required due to heat build-up, min. 35 mm

333

250.5 Integrated screen support Terminal block PE/N (accessory) Supply terminal for power bus Wire range

72 161

Clea rance required due to heat build-up, min. 35 mm

Clearance required due to heat build-up, min. 35 mm

31

Integrated screen support

Terminal block PE/N (accessory)

Motor connections

ICU24F control unit

IPM25 converter power module, 0.75 kW

Clea rance required due to heat build-up, min. 35 mm

156 137.5 11.7

144.8 130

66

Mounting rail 35 x 7.5 mm

100

333

250.5
Motor connections Supply terminal for power bus Terminal block PE/N (accesso ry) Integrated screen suppo rt

Clea rance G_D011_EN_00055a required due to heat build-up, min. 35 mm

Clea rance 31 required due to heat build-up, min. 35 mm

Integrated screen suppo rt

Terminal block PE/N (accesso ry)

IPM25 converter power module, 2.2 kW and 4.0 kW

5/128

Siemens IK PI 2009

Wire range

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions (continued)

24

200

75.5 56

187 200
G_D011_EN_00062

120 141.5

1.5

Terminals 10 mm2 Tightening torque of screw 1.2 ... 1.5 Nm PE M6 x 24 Tightening torque 4.8 0.2 Nm

35 60

110

255 265

4.5

5
Fixing with M4 bolts
G_D011_EN_00084

EMC filter, 50 A

Output reactor for IPM25 FS A

24

200

G_D011_En_00063

120 141.5

150 120

200 213
1.5

255 265
G_D011_EN_00085

4.5

35 60

PE M6 x 24 Tightening torque 4.8 0.2 Nm

Terminals 4 mm2 Tightening torque of screw 0.5 ... 0.6 Nm

Fixing with M4 bolts

EMC filter, 25 A

Output reactor for IPM25 FS B

70

Siemens IK PI 2009

5/129

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


ET 200S FC fail-safe frequency converter

SIMATIC ET 200 distributed I/Os

Dimensions (continued)

75.5 56

287 300 334

5
Fixing with M4 bolts
G_D011_EN_00086

LC filter for IPM25 FS A

110 150 138

280 293 340

100

Fixing with M4 bolts

LC filter for IPM25 FS B

5/130

Siemens IK PI 2009

G_D011_EN_00087

120

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety modules local

SIMATIC ET 200 distributed I/Os

Overview
PM-D F1 safety module DS1-x standard direct starter PM-X safety module PM-D F2 safety module DS1e-x high feature direct starter PM-X safety module

Terminal module for PM-X safety module

IM 151 interface module

G_NSA0_00434

5
Terminal module for PM-D F1/2 safety module Terminal module for direct starter without TM-DS65-S31 supply connection Terminal module for PM-D F1/2 safety module Terminal module for PM-X safety module Terminal module for direct starter without TM-DS45-S31 supply connection PE/N terminal block without M65-PEN-S supply connection

Auxiliary switch of the failsafe equipment for F-Kit 1 direct starter Terminal module for direct starter with TM-DS45-S32 supply connection PE/N terminal block with M65-PEN-F supply connection

Terminal module for direct starter with TM-DS65-S32 supply connection

Interplay of ET 200S Safety motor starter Solutions local components

Safety motor starters Solutions local For use of Standard, High-Feature or Failsafe motor starters in systems with safety categories 2 to 4 (according to EN 954-1) No complex wiring for conventional safety technology Can also be used in combination with external safety relays Can also be used to activate external safety systems Safety module available for function-monitored and automatic starting Safety module available for stop category 0 and 1 Safety module for monitoring the auxiliary voltages for motor starters Safety modules can be plugged into the TM-PF30 terminal modules.

PM-D F1 safety module

Siemens IK PI 2009

5/131

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety modules local

SIMATIC ET 200 distributed I/Os

Overview (continued)
PM-D F1/F2/F3/F4/F5 safety modules PM-D F1/F2/F3/F4 safety modules monitor auxiliary voltages and contain the complete functionality of a safety relay: - PM-D F1 For evaluation of EMERGENCY-STOP circuits with the "monitored start" function. - PM-D F2 For monitoring of protective doors with the "automatic start" function. - PM-D F3 Expansion to PM-D F1/F2 for time-delayed disconnection. - PM-D F4 For expansion of safety circuits with other ET 200S motor starters, e.g. in a different line. - PM-D F5 Transmits the status from PM-D F1 ... 4 through four floating enabling circuits to external safety equipment (contact multiplier) The PM-D F1 and PM-D F2 modules can be combined with the PM-D F3 or PM-D F4 modules. A PM-D F5 can be positioned at any point between a PM-D F1 ... 4 and a PM-X. Safety modules monitor the U1 and U2 auxiliary voltages. A voltage failure is relayed as a diagnostic signal over the bus. - No additional PM-D safety module is required when the safety modules are used. - Each safety circuit, beginning with a PM-D F1 ... 4, must be terminated with one PM-X each. Failsafe Kit The Failsafe Kit (F-Kit) must be added to each Standard motor starter in a safety segment in order to monitor the switching function. F-Kit 1 supplements the DS1-x direct-on-line starter, F-Kit 2 the RS1-x reversing starter. The F-Kits are comprised of: Contact supports for the terminal modules One or two auxiliary switch blocks for the contactor/contactors of the motor starter Connecting cables High-Feature motor starters and their terminal modules come as standard with the functionality of the F-Kits integrated. Examples The diverse possible uses of the Safety motor starters Solutions local are presented in the manual SIMATIC ET 200S motor starters in the context of typical sample applications. Safety functional examples for easy, quick and low-cost implementations of applications with Safety motor starters Solutions local are available in the Internet: You can find more information in the Internet at: http://www.siemens.com/sirius-starting http://www.siemens.com/ET200S
NSA0_00431a

Example 1:

PLC

PM-D F1

PM-D F2 PM-X PM-X

PROFINET PROFIBUS ET 200S

Motor 1

Motor 2

Motor 3

Motor 4

Motor 5

EMERGENCY-STOP

Position switch with sep. actuator

NSA0_00433a

ET 200S Safety motor starter Solutions local with 2 safety circuits (= switch-off groups), Standard motor starters and High-Feature motor starters. Example 2:
PM-D FX1 PROFINET PROFIBUS ET 200S Standard PLC

Version 1 Safety relay, e. g. 3TK28

Version 2 ASIsafe

Motor 1

Motor 2

AS-i

AS-i

ET 200S Safety motor starters Solutions local with 2 external safety combinations (= safety relays or ASIsafe monitors) and with Failsafe motor starters (PM-DFX1 application). 2 of the 6 available safe switch-off groups are used. Signals with relevance for safety can be input to ET 200S through a PM-DFX1 infeed terminal module through the enabling circuits of the ASIsafe monitor or the safety relay to control the Failsafe motor starters which then selectively switch off the downstream motors.

5/132

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety modules local

SIMATIC ET 200 distributed I/Os

Application
Safety motor starters Solutions local With the Safety motor starters Solutions local it is easy to configure several safety circuits. The safety sensors are connected directly and locally to the safety modules. These safety modules perform the work of the otherwise obligatory safety relays and safely shut down the downstream motor starters in accordance with the function selected. The crosslinks required for this are already integrated in the system and need no additional wiring. All signals from the safety modules are automatically relayed as diagnostic signals, e. g. in the event of crossover in the EMERGENCY-STOP circuit. The highest safety category 4 according to EN 954-1 can be obtained with Safety motor starters Solutions local. They can thus be used for evaluation of EMERGENCY-STOP circuits or for monitoring protective doors and also for time-delayed disconnections. With the contact multiplier the safety-relevant signals can also be made available to external systems. All standard safety applications can be covered through combination of different TM-PF30 terminal modules. Needless to say, ET 200S motor starters can also be used in conjunction with external safety relays or with ASIsafe. Use of the PM-DFX1 safety module: The PM-DFX1 safety module is used for feeding in 1 to 6 switch-off groups. The infeed voltage can be switched using 1 to 6 external safety shutdown devices (either ASIsafe monitors or 3TK28 safety relays). This safety module is used in applications with external safety shutdown devices where there is a need for the fully selective safety shutdown of failsafe motor starters/frequency converters (see example 2, page page 132). With the Safety motor starters Solutions local, up to 80 % of wiring is saved compared to conventional safety technology with local safety applications. Terminal modules for (TM-PF30) safety module For supplying load and sensor voltage to the potential bars of the motor starters, and for connection of the 2-channel sensor circuit (e.g. EMERGENCY-STOP pushbutton) and a reset button. Different terminal modules are available for the configuring of separate safety circuits or for the cascading of safety circuits, and for applications with time-delayed disconnection. Terminal modules for (TM-X) safety module For connection of an external infeed contactor (2nd shutdown possibility). With terminals for contactor coil and feedback contact. Is always required to terminate a group of safety-oriented motor starters.

Siemens IK PI 2009

5/133

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety modules local

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version Safety modules PM-D F1 With diagnostics Safety module for EMERGENCY-STOP application monitored start PM-D F2 With diagnostics Safety Module for protective door monitoring automatic start PM-D F3 With diagnostics Safety Module for expanding PM-D F1/2 for another voltage group time-delayed 0 to 15 s PM-D F4 With diagnostics Safety Module for expanding PM-D F1/2 for a further voltage group PM-D F5 With diagnostics Safety Module for expansion of the PM-D F1 ... 4 with four floating enabling circuits contact multiplier
3RK1 903-3DA00

Order No. 3RK1 903-1BA00

3RK1 903-1BB00

3RK1 903-1BD00

3RK1 903-1BA00

3RK1 903-1BC00

3RK1 903-1BE00

PM-D FX1 With diagnostics Infeed terminal module for feeding in 1 to 6 switch-off groups FC-M contact multipliers With 4 safe floating contacts

3RK1 903-3DA00

3RK1 903-3CA00

Accessories PM-X Safety Module With diagnostics Module for connecting a safety group and for connecting an external infeed contactor or for connecting to an external safety circuit F-Kit 1 Failsafe equipment for DS1-x Standard motor starters1)
3RK1 903-1CA00

3RK1 903-1CB00

3RK1 903-1CA00

F-Kit 2 Failsafe equipment for RS1-x Standard motor starters1)

3RK1 903-1CA01

3RK1 903-1CA01
1)

The function of the Failsafe-Kit is already integrated into High-Feature motor starters.

5/134

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety modules local

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version Components for Safety Modules Terminal modules TM-PF30 S47-B1 For PM-D F1/2 Safety Modules with infeed U1/U2 and sensor connection TM-PF30 S47-B0 For PM-D F1/2 Safety Modules with sensor connection TM-PF30 S47-C1 For PM-D F3/4 Safety Modules with infeed U1/U2 and actuation input IN+/IN3RK1 903-1AA00

Order No.

3RK1 903-1AA00

3RK1 903-1AA10

3RK1 903-1AC00

TM-PF30 S47-C0 For PM-D F3/4 Safety Modules with infeed U2 TM-PF30 S47-D0 For PM-D F5 Safety Modules TM-X15 S27-01 For PM-X Safety Module TM-P15-S27-01 terminal modules For PM-D power module TM-PFX30 S47-G0/G1 terminal modules For PM-D F X1 Safety Module (infeed terminal module) Infeed left (TM-PFX30 S47-G0) Infeed center (TM-PFX30 S47-G1) TM-FCM30 S47-F01 terminal modules For F-CM contact multipliers

3RK1 903-1AC10

3RK1 903-1AD10 3RK1 903-1AB00 3RK1 903-0AA00

3RK1 903-3AE10 3RK1 903-3AE00 3RK1 903-3AB10

Siemens IK PI 2009

5/135

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety Modules PROFIsafe

SIMATIC ET 200 distributed I/Os

Overview
PM-D F PROFIsafe safety module IM 151 interface module

Terminal module for PM-D F PROFIsafe TM-PF30 S47-F0

NSA0_00435

5
F-DS1e-x failsafe direct starter

F-RS1e-x failsafe reversing starter

Terminal module for F-DS1e-x with TM-FDS65-S32 supply connection Terminal module for F-DS1e-x without TM-FDS65-S31 supply connection PE/N terminal block with M65-PEN-F supply connection

Terminal module for F-RS1e-x without TM-FRS130-S31-01 supply connection

PE/N terminal block without M65-PEN-S supply connection

Interplay of ET 200S Safety motor starter Solutions PROFIsafe components

Safety motor starters Solutions PROFIsafe Sensor and actuator assignment are freely configurable within the framework of the distributed safety concept: The logic of the safety functions is implemented by software. Safety-oriented PROFIsafe communication and the use of a safety-oriented control system are required. Integration of the safety technology in the standard automation is realized through a single bus system (see Advantages of PROFIsafe), using PROFIBUS as well as PROFINET. For the use of Failsafe motor starters in plants with safety category 2 to 4 according to EN 954-1 and SIL 2 and 3 according to IEC 61508. The use of Standard or High-Feature motor starters is also possible with certain assemblies High flexibility (any assignment of sensors to motor starters using the PLC) Full selectivity of disconnection of the Failsafe motor starters No complex wiring for conventional safety technology, e.g. no infeed contactors even in the highest safety category Can also be used to activate external safety systems through F-CM contact multiplier Safety module available for any safety function Safety module available for stop category 0 and 1 Safety module for monitoring the auxiliary voltages for motor starters Safety modules can be plugged into the TM-PF30 terminal modules.

PM-D F PROFIsafe with TM-PF30 S47-F0 terminal module

5/136

Siemens IK PI 2009

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety Modules PROFIsafe

SIMATIC ET 200 distributed I/Os

Overview (continued)
High degree of flexibility with safety technology Failsafe motor starters for PROFIsafe: In EMERGENCY-STOP applications, the Failsafe motor starters are selectively switched off through the upstream PM-D F PROFIsafe safety module. For each safety module, six switch-off groups can be formed. In the first delivery stage, the failsafe freely-programmable logic of the SIMATIC controller is used to interface with the relevant Failsafe sensor technology. The interface between PROFIsafe and installations that use conventional safety technologies is implemented through the F-CM Failsafe contact multiplier with four floating contacts. Example: The diverse possible uses of the Safety motor starter Solutions PROFIsafe are presented in the manual SIMATIC ET 200S Motor Starters in the context of typical sample applications. Safety functional examples for easy, quick and low-cost implementations of applications with safety motor starters Solution PROFIsafe are available on the Internet: You can find more information in the Internet at: http://www.siemens.com/sirius-starting http://www.siemens.com/ET200S
PM-D F PROFIsafe ET 200S PROFINET PROFIBUS

Application
Safety motor starters Solutions PROFIsafe If a safety-oriented SIMATIC CPU is used, the ET 200S is available as a safety-oriented peripheral. Nevertheless, in such a station it is possible to configure conventional motor starters and input/output modules mixed with modules with safety functions. Thanks to the PROFIsafe profile, the safety functions are available in the complete network, which means that the Safety motor starter Solutions PROFIsafe enable the selective disconnection of a Failsafe motor starters or the disconnection of a group of Standard and High-Feature motor starters regardless of where and on which peripheral station the safe control devices were connected. As such, this solution provides an unprecedented level of flexibility and reduction of wiring for applications in widespread plants or with a sporadic demand for changes in the assignment of safety segments. The Safety motor starter Solutions PROFIsafe are ideally suited for safety concepts with category 2 to 4 according to EN 954-1 or up to SIL 3 according to IEC 61508. Each safety module switches up to 6 switch-off groups for Failsafe motor starters/frequency converters. PM-D F PROFIsafe Safety Module The PM-D F PROFIsafe Safety Module receives the shutdown signal from the interface module of the ET 200S and safely switches off 1 to 6 switch-off groups. This safety module is used in PROFIsafe applications where there is a need for the selective safety shutdown of Failsafe motor starters/frequency converters.

F-PLC

EMERGENCYMotor 1 STOP

Motor 2

EMERGENCY STOP

Position switch

Cable-operated switch
NSA0_00432a

ET 200S Safety motor starters Solutions PROFIsafe with Failsafe motor starters and fully selective disconnection (PM-DF PROFIsafe application)

Within an ET 200S station the Failsafe motor starters are assigned to one of 6 safety segments. For plants with distributed configuration the shutdown signals of these safety segments are preferably issued by a higher-level, safety-oriented control system through PROFIsafe. This permits the greatest flexibility for assigning the motor starters to different safety circuits. Alternatively, an ET 200S F-CPU can also be used for control purposes.

Siemens IK PI 2009

5/137

Siemens AG 2008

ET 200S Safety Motor Starter and Frequency Converter Solutions local/PROFIsafe


Safety Modules PROFIsafe

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version PM-D F PROFIsafe Safety Module For PROFIBUS and PROFINET For Failsafe motor starters, for Failsafe contact multipliers, with six switch-off groups (SG1 to SG6) F-CM contact multipliers With 4 safe floating contacts Components for safety modules PROFIsafe TM-PF30 S47-F0 terminal modules For PM-D F PROFIsafe Safety Module TM-FCM30 S47-F01 terminal modules For F-CM contact multipliers Components for frequency converters and Failsafe frequency converters TM-ICU15 terminal module For ICU24 / ICU24F control module of the frequency converter TM-IPM65 terminal module For IPM25 power section, 0.75 kW of the frequency converter 3RK1 903-3EA10 3RK1 903-3AA00 3RK1 903-3AB10 Order No. 3RK1 903-3BA01

3RK1 903-3CA00

With incoming power bus connection (TM-IPM65-S32) Without incoming power bus connection (TM-IPM65-S31) TM-IPM130 terminal module For IPM25 power section, 2.2 kW and 4.0 kW of frequency converter With incoming power bus connection (TM-IPM130-S32) Without incoming power bus connection (TM-IPM130-S31) Terminal blocks PE/N M65-PEN-F With incoming power bus connection, with caps M65-PEN-S terminal blocks without incoming energy connection

3RK1 903-3EC00 3RK1 903-3EC10

3RK1 903-3ED00 3RK1 903-3ED10 3RK1 903-2AC00

3RK1 903-2AC10

5/138

Siemens IK PI 2009

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Terminal modules for ET 200S motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Overview

Application
Terminal modules for motor starters and frequency converters Terminal modules are purely mechanical components for accommodating the ET 200S peripherals. The self-assembling voltage buses integrated in the terminal modules reduce wiring outlay to the single infeed. All modules following on the right are automatically supplied upon plugging the terminal modules together. The robust design and keyed connection technology enables use in harsh industrial conditions. The terminal modules for motor starters and frequency converters are available in different versions: Terminal modules for TM-DS and TM-RS motor starters Terminal modules for frequency converters: - TM-ICU for the control modules - TM-IPM for the power sections Terminal modules for expansion modules (TM-xB) Terminal modules for TM-DS and TM-RS motor starters The TM-DS and TM-RS terminal modules are available in various versions for the Standard motor starters and the High-Feature motor starters. The terminal modules with the suffix "-S32" have connection terminals for feeding into the integrated 40 A/50 A power bus and connection terminals for the motor connection cable. They are mounted at the beginning (left) of a power bus segment. The terminal modules with the suffix "-S31" have only connection terminals for the motor connection cable. These terminal modules follow on the right after a "-S32" terminal module. To configure a new load group, another "-S32" terminal module is plugged in. All connection terminals of the terminal modules for motor starters are equipped with strong 10 mm terminals. The "-S32" terminal modules are supplied with three caps for closing the power bus contacts on the final terminal module of a segment. Terminal modules for frequency converters The TM-ICU terminal module is used for both ICU24 and ICU24F control modules (without or with integrated safety functions). A TM-IPM is then always plugged in after a TM-ICU. The TM-IPM with a width of 65 mm is used to accommodate the IPM25 power section with 0.75 kW. A terminal module with a width of 130 mm is needed for the power sections with 2.2 or 4.0 kW. Each TM-IPM terminal module has an integrated screen attachment for complying with EMC Class A acc. to EN 55011. The terminal modules with the suffix "-S32" have connection terminals for feeding into the integrated 50 A power bus and connection terminals for the motor connection cable. They are mounted at the beginning (left) of a power bus segment. The terminal modules with the suffix "-S31" have only connection terminals for the motor connection cable. These terminal modules follow on the right after a "-S32" terminal module. To configure a new load group, another "-S32" terminal module is plugged in. All connection terminals of the terminal modules for frequency converters are equipped with strong 10 mm terminals. The "-S32" terminal modules are supplied with three caps for closing the power bus contacts on the final terminal module of a segment.

Terminal modules for motor starters Mechanical modules in which the motor starter and expansion modules are inserted For constructing the permanent wiring and self-assembling voltage bus For connecting the motor connection cables Positive-locking connection to ensure enhanced vibration resistance Terminal modules for frequency converters Mechanical modules in which the components of the frequency converter are inserted For constructing the permanent wiring and self-assembling voltage bus For connecting the motor cables Integrated screen attachment for EMC-compatible wiring for complying with EMC Class A acc. to EN 55011 Terminal module for power module Connection by means of screw terminals Light colored enclosure for visual distinction Always before the first TM-DS/TM-RS

Siemens IK PI 2009

5/139

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Terminal modules for ET 200S motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Application
Terminal modules for expansion modules (TM-xB) The TM-xB terminal modules are used to accommodate the xB1, xB2, xB3 and xB4 brake control modules. The TM-xB terminal module must always follow directly after a terminal module for Standard motor starters, High-Feature motor starters or frequency converters as control of the solid-state braking switch is provided through an output of the motor starter/frequency converter. The xB215 terminal modules for the brake control modules have not only the terminals for connecting the cable for the motor brake but also the terminals of the two local acting inputs. These local inputs are not evaluated by a frequency converter; for this reason the xB215 terminal module may be plugged in only downstream from a motor starter (Technical Specifications, Selection and Ordering Data, see the section "Accessories for Motor Starters and Frequency Converters"). PE/N terminal blocks The PE/N terminal block is required for direct connection of the protective conductor in the motor cable without intermediate terminals. It is plugged together with the terminal module for motor starters or frequency converters before the latter is mounted on the standard mounting rail. With two PE terminals and one N terminal the "-F" version is connected to the "-S32" terminal modules for motor starters or frequency converters. The "-S" version is combined with the "-S31" terminal module. The "F" terminal modules are delivered with two caps for closing the PE/N bus contacts on the final terminal module of a segment. The modules for the Standard motor starters have a width of 45 mm and the modules for the High-Feature motor starters and frequency converters have a width of 65 mm. There is no electrical connection between the terminals of the PE/N terminal block and the integrated shielding of the frequency converter. The PE/N terminal block must therefore not be used for the shielding of the motor cable.

Selection and ordering data

Version Components for Standard motor starters Terminal modules TM-DS45-S32 for DS1-x direct-on-line starters with incoming power bus connection including three caps for terminating the power bus

Order No.

3RK1 903-0AB00

3RK1 903-0AB00

TM-DS45-S31 for DS1-x direct-on-line starters without incoming power bus connection

3RK1 903-0AB10

3RK1 903-0AB10

TM-RS90-S32 for RS1-x reversing starters with incoming power bus connection including three caps for terminating the power bus

3RK1 903-0AC00

3RK1 903-0AC00

TM-RS90-S31 for RS1-x reversing starters without incoming power bus connection

3RK1 903-0AC10

5/140

Siemens IK PI 2009

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Terminal modules for ET 200S motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Selection and ordering data (continued)


Version PE/N M45-PEN-F terminal block 45 mm wide incl. two caps in combination with TM-DS45-S32 / TM-RS90-S32 Order No. 3RK1 903-2AA00

3RK1 903-2AA00

PE/N M45-PEN-S terminal block 45 mm wide in combination with TM-DS45-S31 / TM-RS90-S31

3RK1 903-2AA10

3RK1 903-2AA10

Components for High-Feature motor starters Terminal modules TM-DS65-S32 for DS1e-x and DSS1e-x direct-on-line starters with incoming power bus connection including three caps for terminating the power bus TM-DS65-S31 for DS1e-x and DSS1e-x direct-on-line starters without incoming power bus connection TM-RS130-S32 for RS1e-x reversing starters with incoming power bus connection including three caps for terminating the power bus TM-RS130-S31 for RS1e-x reversing starters Without incoming power bus connection M65-PEN-F terminal block 65 mm wide incl. two caps in combination with TM-DS65-S32 / TM-RS130-S32 M65-PEN-S terminal block 65 mm wide in combination with TM-DS65-S31 / TM-RS130-S31 Components for power modules TM-P15 S27-01 terminal module For PM-D power module 3RK1 903-0AA00 3RK1 903-0AK00

3RK1 903-0AK10

3RK1 903-0AL00

3RK1 903-0AK00

3RK1 903-0AL10

3RK1 903-2AC00

3RK1 903-2AC10

3RK1 903-0AA00

Components for frequency converters and Failsafe frequency converters TM-ICU15 terminal module For ICU24 / ICU24F control module of the frequency converter TM-IPM65 terminal module For IPM25 power section, 0.75 kW of the frequency converter With incoming power bus connection (TM-IPM65-S32) Without incoming power bus connection (TM-IPM65-S31) TM-IPM130 terminal module For IPM25 power section, 2.2 kW and 4.0 kW of the frequency converter With incoming power bus connection (TM-IPM130-S32) Without incoming power bus connection (TM-IPM130-S31) M65-PEN-F terminal block M65-PEN-S terminal block 3RK1 903-3ED00 3RK1 903-3ED10 3RK1 903-2AC00 3RK1 903-2AC10 Siemens IK PI 2009 3RK1 903-3EC00 3RK1 903-3EC10 3RK1 903-3EA10

5/141

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Accessories for motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Overview
Accessories for Frequency Converters Brake control modules XB1 and XB3 If required, the XB1 and XB3 brake control modules can be arranged on the right-hand side next to the IPM25 power section of the ET 200S FC frequency converter. Using the brake control module it is possible to connect a motor brake to the converter. Actuation takes place through the internal brake control of the converter. EMC filter for frequency converters For compliance with EMC Class A according to EN 55011 an EMC filter is connected to the 400 V infeed supply of the first frequency converter on the 400 V power bus. The EMC filter must be conductively mounted on a large area on a grounded mounting wall in the control cabinet. The correct EMC installation additionally requires continuously shielded cables within the the control cabinet., i.e. from the cabinet infeed to the EMC filter, from the EMC filter to the frequency converter, and from each frequency converter to the motor. The shielding of each cable has to be connected on both ends and preferrably over a large area. The cable shields and the internal shieldings of the frequency converter are connected via the ET 200S accessories shield bar and shield clamps and the shield support integrated in the terminal module of the frequency converter. The route of the shields grounding must be as short as possible. The EMC filter is available in two frame sizes for 25 A and 50 A rated current. Both EMC filters are designed for a maximum cable length of 350 m. This cable length refers to the sum of all motor cables of all converters that share a common 400 V power bus. MMC parameter memory If required, an additional storage medium can be used for the the parameterization of the frequency converter. The MMC permits replacement of the ICU24/ICU24F control module with automatic downloading of parameters from the MMC into the internal parameter memory of the ICU24/ICU24F. Suitable for the MMC slot of the ICU24/ICU24F control module. Other memory cards are not accepted by the ICU24/ICU24F. Connection cable from a PC to the ICU24/ICU24F control module The cable creates a point-to-point connection from the PC to the ICU24/ICU24F control module for starting up the converter with the "STARTER" PC tool.

Technical specifications
Brake control module XB1 Use with ET 200S FC frequency converter Dimensions (W x H x D) in mm Number of assigned outputs for the (left-hand) motor starter Rated operating voltage in V Power supply Rated operational current in A Reverse polarity protection Overload/short-circuit protection Conductor cross-section of the terminal module for the brake control module in mm2 Number of outputs Number of inputs Address area required per module With summary Without summary Diagnostics functions Group fault "SF" Switching state for brake "STAT" Inputs 1 and 5 Parameters (default values underlined) Brake overload diagnostics Input delay in ms Module width in mm --15 Disable/Enable 0 / 0.1 / 0.5 / 3 / 15 --Disable/Enable 0 / 0.1 / 0.5 / 3 / 15 Red LED Yellow LED -Green LED -Green LED 0 0 2 bits 1 byte 0 0 2 bits 1 byte Yes Brake control module XB3 No Brake control module XB2 Yes Brake control module XB4 No

15 x 196.5 x 125.5 incl. terminal module on 7.5 mm standard mounting rail 1 DC 24 Externally through terminal module 4 500 DC (min. 100) From brake rectifier through terminal module 0.7

No, in the event of polarity reversal the brake is released and the overload/short-circuit protection is not effective Yes, solid-state 1 x 2.5 without end sleeve 1 x 1.5 with end sleeve 0 0 1 (used internally) 2 0 0 1 (used internally) 2

5/142

Siemens IK PI 2009

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Accessories for motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Selection and Ordering Data


Version Brake control modules For motors with a mechanical brake xB1 for motor starters and frequency converters 24 V DC / 4 A xB2 for motor starters and frequency converters 500 V DC / 0.7 A
3RK1 903-0CB00

Order No.

3RK1 903-0CB00

3RK1 903-0CC00

xB3 for motor starters 24 V DC / 4 A / 2 DI DC 24 V local control With diagnostics; with two inputs xB4 for motor starters 500 V DC / 0.7 A / 2 DI DC 24 V local control With diagnostics; with two inputs Terminal module for brake control modules TM-xB15 S24-01 for xB1 or xB2 TM-xB215 S24-01 for xB3 or xB4 EMC filter for frequency converter For achieving EMC Class A; is connected before shared power bus of frequency converters, installation must comply with EMC guidelines (shielded motor cables) 25 A rated current 50 A rated current MMC parameter memory for frequency converter Matches the MMC slot of the ICU24 / ICU24F closed-loop control module; other memory cards are not accepted RS 232/zero modem cable (5 m) Cable for commissioning the ET 200S FC frequency converter using the PC tool "STARTER"

3RK1 903-0CE00

3RK1 903-0CF00

3RK1 903-0AG00 3RK1 903-0AG01

5
6SL3 203-0BE22-5AA0 6SL3 203-0BE25-0AA0 6SL3 254-0AM00-0AA0

6ES7 901-1BF00-0XA0

Documentation ET 200S FC Frequency Converter Operating Instructions + List Manual for the ET 200S FC Frequency Converter German English Operating Instructions + List Manual for the ET 200S FC Frequency Converter + Manual ET 200S German English CD-ROM with documentation (STARTER, etc.) multilanguage 6SL3 298-0CA12-1AP0 6SL3 298-0CA12-1BP0 6SL3 298-0CA11-1MG0 6SL3 298-0CA12-0AP0 6SL3 298-0CA12-0BP0

Siemens IK PI 2009

5/143

Siemens AG 2008

ET 200S Components for Motor Starter and Frequency Converter


Accessories for motor starters and frequency converters

SIMATIC ET 200 distributed I/Os

Dimensions
117,5 15

66

13,5

142,2

194,6 100

195,6

5
95 7

Brake control module xB1 ... 4 with terminal module TM-xB215

5/144

Siemens IK PI 2009

NSA00304

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Software
Motor Starter ES

Overview
Motor Starter ES for parameterization, monitoring, diagnostics and testing of motor starters Note: More information about ES Motor Starters, see Section 9.

Selection and ordering data


Version Motor Starter ES 2007 Basic Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Motor Starter ES 2007 Standard Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Motor Starter ES 2007 Premium Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Accessories For ET 200S High Feature motor starters Control module 2DI DC 24 V COM, for ET 200S High-Feature starter, Failsafe Starter A LOGO! PC cables For ET 200pro motor starters RS 232 interface cable, serial data connection between ET 200pro MS/FC and laptop/PC/PG or MS For ECOFAST High Feature motor starters (interface cable) PC cables USB/serial adapter To connect the PC cable to the USB port of a PC, we recommend, in conjunction with 3RW44 soft starter, using SIMOCODE pro 3UF7, 3RK3 modular safety system, ET 200S/ECOFAST/ET 200pro motor starter, AS-i safety monitor, AS-i analyzer 3RK1 903-0CH10 6ED1 057-1AA00-0BA0 3RK1 922-2BP00 Order No.

3ZS1 310-4CC10-0YA5

3ZS1 310-5CC10-0YA5

3ZS1 310-6CC10-0YA5

3RK1 911-0BN20 3UF7 946-0AA00-0

Siemens IK PI 2009

5/145

Siemens AG 2008

ET 200S Software
Overview

SIMATIC ET 200 distributed I/Os

STARTER commissioning tool


In addition, the following functions are available for optimization purposes: Self-optimization (depending on drive) Trace (depending on drive) Diagnostics functions provide information about: Control/status words Parameter status Operating conditions Communication states Performance Easy to use: Only a small number of settings need to be made for successful first commissioning: Axis turning Solution-based dialog-based user guidance simplifies commissioning. Self-optimization functions reduce manual effort for optimization. The built-in trace function provides optimum support during commissioning, optimization and troubleshooting. The easy-to-use STARTER commissioning tool can be used to: Start up Optimize and Diagnose This software can be operated either as a standalone PC application or can be integrated into the SCOUT engineering system (on SIMOTION) or STEP 7 (with Drive ES Basic). The basic functions and handling are the same regardless. In addition to the SINAMICS drives, the current version of STARTER also supports MICROMASTER 4 devices and inverters for the SIMATIC ET 200S FC distributed I/O system. The project wizards can be used to create the drives within the structure of the project tree. Beginners are supported by solution-based dialog guidance, whereby a standard graphics-based display maximizes clarity when setting the drive parameters. First commissioning is guided by wizards, which make all the basic settings in the drive. This ensures that even though only a small number of parameter settings have been made, the drive configuration has already progressed far enough to permit axis movement. The individual settings required are made using graphics-based parameterization screen forms, which also display the mode of operation. Examples of individual settings that can be made include: Terminals Bus interface Setpoint channel (e.g. fixed setpoints) Closed-loop speed control (e.g. ramp-function generator, limits) BICO interconnections Diagnostics Experts can gain rapid access to the individual parameters via the Expert List and do not have to navigate dialogs. Minimum hardware and software requirements PG device or PC with Pentium III 1 GHz (Windows 2000), Pentium III 1 GHz (Windows XP) 512 MB RAM (1 GB RAM recommended) Screen resolution 1024 768 pixels, 16-bit color depth Free hard disk memory: 1.6 GB, 2.3 GB for SCOUT stand-alone Windows XP Professional SP2 Microsoft Internet Explorer 6.0

Integration
Depending on the system configuration, the Control Unit (CU) or the complete inverter can communicate with the programming device (PG) or PC by means of a serial interface, via PROFIBUS or PROFINET. The following accessories can be ordered for the relevant drive system: SINAMICS G130/G150/S120 A PROFIBUS communications module and a connecting cable are required to make the communication link between the PG/PC and a Control Unit. For example, PROFIBUS communications module CP 5512 (PCMCIA type 2 card + adapter with 9-pin Sub-D socket for connection to PROFIBUS. For MS Windows 2000/XP Professional and PCMCIA 32) Order No.: 6GK1551-2AA00 and connecting cable between CP 5512 and PROFIBUS Order No.: 6ES7901-4BD00-0XA0 SINAMICS G110/G120 and MICROMASTER 4 PC inverter connection kits are available for MICROMASTER 4, SINAMICS G110 and SINAMICS G120 for a safe point-to-point connection to the PC. Order No. for MICROMASTER 4: 6SE6400-1PC00-0AA0 (the scope of supply includes a 9-pin Sub-D connector and a RS232 standard cable, 3 m) Order No. for SINAMICS G110 and SINAMICS G120: 6SL3255-0AA00-2AA1 (the scope of supply includes a 9-pin Sub-D connector, a RS232 standard cable, 3 m and the STARTER startup tool on DVD)

5/146

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200S Software

STARTER commissioning tool

Ordering data
STARTER commissioning tool for SINAMICS and MICROMASTER German / English / French / Italian / Spanish Optional package Drive Control Chart (DCC) for SINAMICS G130/G150/S120 German/English/French/ Italian/Spanish, single-user license Note: DCC can be used only if version V4.1 SP1 or higher of the STARTER commissioning tool is installed PROFIBUS communications module CP 5512 PCMCIA type 2 card + adapter with 9-pin Sub-D socket for connection to PROFIBUS. For MS Windows 2000/XP Professional and PCMCIA 32 Connecting cable between CP 5512 and PROFIBUS PC inverter connection kit for MICROMASTER 4 The scope of supply includes a 9-pin Sub-D connector and a RS232 standard cable, 3 m. PC inverter connection kit for SINAMICS G110/G120 The scope of supply includes a 9-pin Sub-D connector, an RS232 standard cable (3 m) and the STARTER startup tool on CD-ROM.

Order No. 6SL3072-0AA00-0AG0

Options
DRIVE CONTROL CHART (DCC) Drive Control Chart (DCC) enlarges the possibility of easy configuring technological functions for the SINAMICS G130 and G150 drives.

6AU1810-1HA20-1XA0

The user-friendly DCC editor enables easy graphics-based configuration, a clear representation of control loop structures as well as a high degree of reusability of existing diagrams. The open-loop and closed-loop control functionality is defined by using multi-instance-enabled blocks (Drive Control Blocks (DCBs)) from a predefined library (DCB library) that are selected and graphically linked by dragging and dropping. Text and diagnostic functions allow verification of program behavior or the identification of causes in the event of faults.

6GK1551-2AA00

The block library contains a large selection of control, arithmetic and logic blocks as well as extensive open-loop and closed-loop control functions. For SINAMICS S120, Drive Control Chart also provides a convenient basis for resolving drive-level open-loop and closedloop control tasks directly in the converter. This results in further adaptability of SINAMICS to specific tasks. On-site processing in the drive supports modular machine concepts and results in increased overall machine performance. DCC is an add-on for the aforementionend SINAMICS G130, SINAMICS G150 and SINAMICS S120 drives to the STARTER commissioning tool and available as a supplementary option package.

6ES7901-4BD00-0XA0 6SE6400-1PC00-0AA0

6SL3255-0AA00-2AA1

More information
The commissioning tool STARTER is also available on the Internet under http://support.automation.siemens.com/ WW/view/en/10804985/133100

Siemens IK PI 2009

5/147

Siemens AG 2008

ET 200iSP
Overview

SIMATIC ET 200 distributed I/Os

Overview

Failsafe distributed I/O system to degree of protection IP30 for use in hazardous gaseous and dusty areas, i.e. in Zones 1 and 2 as well as 21 and 22 Sensors and actuators can also be situated directly in Zone 0 or 20 Individual configuration and flexible expansion with the modular design for optimization to the respective automation task Independent wiring enables prewiring without the electronics connected Optimized for integration into process control systems (e.g. SIMATIC PCS 7) Parameters can be assigned using SIMATIC PDM Optimal integration of HART field devices (HART transparency) Connection to PROFIBUS DP via isolating transformers Module replacement (hot swapping) and configuration expansion (Configuration in Run) possible during operation Extensive diagnostics possibilities Condensation-proof modules in temperature range -20C to +70C EMC in accordance with NE 21 (on Namur recommendation) Full redundancy of PROFIBUS and power supply

Application
The ET200iSP distributed I/O system is designed in degree of protection IP30. It is used wherever explosion protection for gases and dust is required in accordance with device group I and II. The ET200iSP system is designed in accordance with ATEX Directive 94/9/EC required for the European market when introducing new devices into areas subject to explosion hazard. The design of the system also enables use under increased mechanical load such as are found on oil platforms. The system consists of terminal modules to which the relevant function units such as the power supply, interface module and electronics modules are connected. Thanks to this selective design, the system can be adapted optimally to plant-specific requirements in areas subject to explosion hazard. This enables, for example, fast replacement of individual functional units under power. In the event of a fault, only small plant sections are affected since only a few channels are processed in one module. Use of an ET200iSP station enables significant savings compared to a conventional design. There is no need for isolating stages or sub-distribution boards and cabling costs are reduced since the station functions locally like a terminal block. Startup and troubleshooting are simplified thanks to the extensive diagnostics facilities. As well as analog input modules and analog output module with and without HART functionality, the existing range of input/output modules also encompasses digital input/output modules whose functionality can be parameterized. The system is optimally adapted to use with SIMATIC S7 and SIMATIC PCS 7 use on other process control systems and SIMATIC S5 is possible by means of integration using a GSD file.

5/148

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP
Overview

Design
One distributed I/O station (= remote I/O) ET 200iSP comprising: One terminal module for the power supply unit, as well as the relevant power supply module in degree of protection EX d (explosion-proof enclosure) One terminal module for the PROFIBUS interface module, as well as the relevant IM 152 interface module. In the case of a single PROFIBUS interface module, there is another slot on the terminal module for an electronics module. If the PROFIBUS interface module is used redundantly, a terminal module is available that can accommodate two IM 152. Up to 32 terminal modules for electronics modules, as well as digital and analog electronics modules for plugging into them. One terminal module can accommodate 2 electronics modules. One terminating module included in the scope of supply of the IM 152. The station is assembled on an S7-300 mounting rail in accordance with the above list, starting with the terminal module of the power supply unit, then the terminal module for the PROFIBUS interface module, followed by the desired terminal modules for the electronics modules. When the terminal modules are connected, it is possible to wire them and check the wiring even before any electronics modules are connected. The relevant electronics modules are plugged into the terminal modules. The electronics modules used are mechanically key coded on first use. The terminal modules and electronics modules are installed without tools. The maximum configuration is limited by the 32 electronics modules, corresponding to a station length of 107 cm. The maximum possible number of modules can be limited by the current consumption of the actual modules used. Up to 16 modules can be used without restriction. With a higher degree of expansion, the configuring rule must be observed. In the areas subject to explosion hazard, PROFIBUS must be managed with intrinsic safety by means of a suitable fieldbus isolating transformer (RS 485IS coupler). The 24-V connection to the power supply terminal is carried out using EX e terminals. This connection must not be disconnected under Ex conditions. The incoming power supply must be installed in the safe area. For use in areas subject to explosion hazard, installation in a suitable EX enclosure is required (varies according to zone, e.g. an EX enclosure IP54 for Zone 1). Accessories: The following accessories can be supplied for the ET 200iSP: Pre-perforated DIN A4 labeling sheets in different colors for electronics modules, machine printable Slot number plate for identifying the terminal modules

Function
Operating mode Through PROFIBUS DP (up to 1.5 Mbit/s), a central PLC can access the electronic modules of the ET 200iSP station just like a central I/O module. Communication is handled by the master interface in the central PLC and the interface module of the ET 200iSP (= IM 152-1). The diagnostics integrated in the system reduce startup and debugging times. The physical bus setup for devices in hazardous areas requires special protective measures. The method of the intrinsically safe PROFIBUS has been selected for ET 200iSP. This demands segmentation and power limiting on the bus (PROFIBUS RS 485-IS). A commercially available "Fieldbus isolating transformer" (RS 485IS coupler) is used for this purpose. It can be installed in areas up to Zone 2. This converts the PROFIBUS DP to an intrinsically safe PROFIBUS RS 485-IS, which allows modules to be plugged and pulled even under potentially explosive conditions. Configuration An ET 200iSP station can be connected to higher level PLCs as a DP V0 or DP V1 slave. In an S7/ PCS 7 environment, configuration and parameterization of an ET 200iSP station is executed using SIMATIC STEP 7 hardware manager. This defines the station design (which module where). This software is opened by double-clicking one of the implemented modules/stations. Software requirements SIMATIC STEP 7, Version 5.3 + SP1 incl. Hardware Support Package (HSP) SIMATIC PCS 7, Version V6.1 For configuring HART field devices, the current version of the PDM configuring software is required. Configuring in non-Siemens systems and older PCS 7/STEP 7 versions In all other applications, the configuration of the station must be relayed to the PROFIBUS DP network through the GSD file. In this case, parameterization is carried out through PDM, whereby a comparison of the configuration between PDM and GSD file is not possible. It is not possible to commission an ET 200iSP without the PDM configuration software. The parameters of this module can then be defined in the PDM dialog fields, such as alarm limits for analog modules, sensor selection for digital modules, settings for the release of analog values and the output of HART commands for analog HART modules.

Siemens IK PI 2009

5/149

Siemens AG 2008

ET 200iSP
Overview

SIMATIC ET 200 distributed I/Os

Technical specifications General


Degree of protection Ambient temperature Medial load IP30 -20C to +70C In accordance with ISA-S71.04 severity level G1 ;G2 ;G3 (with the exception of NH3 here only Level G2) Electromagnetic compatibility in accordance with NE21 0.5 g continuously, 1 g periodically Class I cULus Class I,II,II Approvals, standards ATEX IECEx cFMus II 2 G (1) GD I M2 Zone 1 Class I,II,II Ex de [ia/ib] IIC T4 Ex de [ia/ib] I Ex de [ia/ib] IIC T4 NI Division 2, Groups A, B, C, D, E, F, G T4 AIS Division 1, Groups A, B, C, D, E, F, G Zone 1, AEx de [ia/ib] IIC T4 Division 2, Groups A, B, C, D, E, F, G T4 providing int. safe circuits for Division 1, Groups A, B, C, D, E, F, G Zone 1, AEx de [ia/ib] IIC T4

EMC Vibration-proof

Class I

PROFIBUS IEC CE

EN 50170, Volume 2 IEC 61131, Part 2 In accordance with 94/9/EG (ATEX 100a), 89/336/EEC and 73/23/EEC Classification companies ABS (American Bureau of Shipping) BV (Bureau Veritas) DNV (Det Norske Veritas) GL (Germanischer Lloyd) LRS (Lloyds Register of Shipping) Class NK (Nippon Kaiji Kyokai)

Shipbuilding approval

5/150

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

IM 152-1 interface module

Overview
The IM 152 interface module is plugged onto the corresponding terminal module TM-IM/EM (to be ordered separately). For redundant operation, two IM 152 are used. They are plugged onto the TM-IM/IM. The interface module IM 152 has the following properties: - Connects the ET 200iSP to PROFIBUS DP - Prepares data for the fitted electronic modules - The PROFIBUS address of ET 200iSP can be adjusted by switch - Slot for MMC - Firmware updating over PROFIBUS DP or MMC Shutting down the 24 V DC supply voltage at the terminal module TM-PS also shuts down the interface module IM 152. The maximum address size is 244 byte inputs and 244 byte outputs.

Technical specifications
Order No. Current consumption from supply voltage 1L+, max. Power loss, typ. interfaces interface physics, RS 485 Protocols PROFIBUS DP protocol PROFIBUS DP Transmission speed, max. SYNC capability FREECE capability direct data exchange (cross traffic) Isochronous mode Isochronouos mode Status information/ alarms/diagnostics Alarms Alarms Acyclic function, interrupts Acyclic function, parameter Diagnoses Diagnostic functions Diagnostics indication LED Bus error BF (red) Collective error SF (red) Yes Yes Yes Yes Yes Yes No 1.5 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s Yes Yes Yes; Slave to slave as publisher Yes Yes; (intrinsically safe) 30 mA 0.5 W Accuracy Number of stampable digital inputs, max. Time format Time resolution Time interval for transmitting the message buffer if a message is present Time stamp on signal change Isolation between supply voltage and electronics Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx. 245 g 30 mm 129 mm 136.5 mm 8110H Yes II2 G Ex ib IIC T4 and I M2 Ex ib I 04 ATEX 1243 Yes 6ES7 152-1AA00-0AB0 Order No. Time stamping Description for each digital input, digital input module, total ET 200iS 20 ms 64; for accuracy class 20 ms RFC 1119 Internet (ISP) 1 ms 1 000 ms 6ES7 152-1AA00-0AB0

rising / falling edge as signal entering or exiting

Monitoring 24 V voltage supply ON Yes (green)

Siemens IK PI 2009

5/151

Siemens AG 2008

ET 200iSP

SIMATIC ET 200 distributed I/Os

IM 152-1 interface module

Technical specifications (continued)


Order No. Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 235 g Order No. Sheet of labels 6ES7 152-1AA00-0AB0 6ES7 193-7AA00-0AA0 6ES7 193-7AA10-0AA0 6ES7 193-7AB00-0AA0 DIN A4, perforated, consisting of 10 sheets each with 30 labels for electronic modules and 20 labels for IM 152 petrol red yellow light beige 6ES7 152-1AA00-8AA0 6ES7 152-1AA00-8BA0 6ES7 972-0DA60-0XA0 Identification labels, inscribed Order quantity 1 set of 200 of each color for slot numbering 10 x slot 1 to 2 5 x slot 1 to 40 1 x slot 1 to 64 2 x slot 1 to 68 Identification labels, blank Order quantity 1 set of 200 of each color for slot numbering Standard rails S7-300 Standard rail 585 mm Standard rail 885 mm 6ES7 390-1AF85-0AA0 6ES7 390-1AJ85-0AA0 8WA8 861-0AB 8WA8 861-0AC 8WA8 861-0DA 8WA8 848-2AY 6ES7 193-7BH00-0AA0 6ES7 193-7BD00-0AA0 6ES7 193-7BB00-0AA0 6ES7 193-7BA00-0AA0 235 g 195 g Order No. 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm No No 04 ATEX 2242 No No 04 ATEX 2242 No No 04 ATEX 2242 6ES7 193-7AA00-0AA0 6ES7 193-7AA10-0AA0 6ES7 193-7AB00-0AA0

Ordering data
IM 152 including the terminating module

ET 200iSP-IM 152-1 Terminal modules for IM 152 TM-IM/EM60S TM-IM/EM60C TM-IM/IM Accessories ET 200iSP product manual German English Plug connector PROFIBUS connector with active terminating resistor For RS 485-IS circuit; 1.5 Mbit/s RS 485-IS segment Isolating transition for coupling PROFIBUS DP to PROFIBUS RS 485-IS

6ES7 972-0AC80-0XA0

5/152

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

IM 152-1 interface module

Ordering data
Accessories (continued) Stainless steel housing IP66 for hazardous Zone 1 with safety class EEx e Empty housing with no modules installed, for use in gaseous atmospheres, IP65 (IP54 if a breather gland is used) Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules, for use in gaseous atmospheres, with 3 rows of cable glands M16 (41 pieces) and 2 rows of cover plugs Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules for use in gaseous atmospheres with 5 rows of cable glands M16 (66 pieces) Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules, for use in gaseous atmospheres, with 3 rows of cable glands M16 (68 pieces) and 2 rows of cover plugs Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules for use in gaseous atmospheres with 5 rows of cable glands M16 (111 pieces) Empty housing with no modules installed, for use in dusty atmospheres, IP65 Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules, for use in dusty atmospheres, with 3 rows of cable glands M16 (41 pieces) and 2 rows of cover plugs Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules for use in dusty atmospheres with 5 rows of cable glands M16 (66 pieces) Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules, for use in dusty atmospheres, with 3 rows of cable glands M16 (68 pieces) and 2 rows of cover plugs Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules for use in dusty atmospheres with 5 rows of cable glands M16 (111 pieces)

Order No. Accessories (continued) Housing with ET 200iSP modules installed, for use in gaseous atmospheres, IP65 (IP54 when using a breather gland), the ET 200iSP components must be ordered separately 6DL2 804-0AD30 Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules, for use in gaseous atmospheres, with 3 rows of cable glands M16 (41 pieces) and 2 rows of cover plugs Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules for use in gaseous atmospheres with 5 rows of cable glands M16 (66 pieces) Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules, for use in gaseous atmospheres, with 3 rows of cable glands M16 (68 pieces) and 2 rows of cover plugs Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules for use in gaseous atmospheres with 5 rows of cable glands M16 (111 pieces) Housing with modules installed, for use in dusty atmospheres, IP65, the ET 200iSP components must be ordered separately 6DL2 804-0DD30 Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules, for use in dusty atmospheres, with 3 rows of cable glands M16 (41 pieces) and 2 rows of cover plugs Wall housing 650 x 450 x 230 for the installation of up to 15 ET 200iSP modules for use in dusty atmospheres with 5 rows of cable glands M16 (66 pieces) Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules, for use in dusty atmospheres, with 3 rows of cable glands M16 (68 pieces) and 2 rows of cover plugs Wall housing 950 x 450 x 230 for the installation of up to 25 ET 200iSP modules for use in dusty atmospheres with 5 rows of cable glands M16 (111 pieces)

Order No.

6DL2 804-1AD30

6DL2 804-1AD50

6DL2 804-0AD50

6DL2 804-1AE30

6DL2 804-0AE30

5
6DL2 804-1AE50

6DL2 804-0AE50

6DL2 804-1DD30

6DL2 804-0DD50

6DL2 804-1DD50

6DL2 804-0DE30

6DL2 804-1DE30

6DL2 804-0DE50

6DL2 804-1DE50

Siemens IK PI 2009

5/153

Siemens AG 2008

ET 200iSP
Overview

SIMATIC ET 200 distributed I/Os

ET 200iSP digital electronic modules and terminal modules

The electronic modules are plugged into the associated terminal modules that must be ordered separately (with screw-type or spring-loaded terminals). When plugged in, the modules are automatically uniquely coded mechanically. Modules can be replaced under potentially explosive conditions during runtime.

Technical specifications

Order No. Digital inputs Number of NAMUR inputs Cable length cable length, shielded, max. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. - at "1" to "0", min. - at "1" to "0", max. Encoder Number of connectable encoders, max. Connectable encoders NAMUR encoder NAMUR encoder Input current, for signal "0", max. Input current, for signal "1", min. Integrated Functions Frequency meter Frequency measurement Number of frequency meters Counters Number of counter inputs Input frequency, max.

6ES7 131-7RF00-0AB0 8 200 m

Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions

6ES7 131-7RF00-0AB0

Yes; Parameterizable No Yes Yes Yes; R load < 150 ohms with NAMUR sensor/sensor and NAMUR changeover contact/sensor to DIN 19234 Yes

2.8 s 3.5 s 2.8 ms 3.5 s

Diagnostic information readable Short circuit

Diagnostics indication LED 8 Collective error SF (red) Isolation Yes 1.2 mA 2.1 mA Yes Yes; (Gate time) 50 ms; 200 ms; 1 s 2 2; normal and periodic count function 5 kHz; with a cable length of 20 m: 5 kHz; with a cable length of 100 m: 1 kHz; with a cable length of 200 m: 500 Hz Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 255 g 30 mm 129 mm 136.5 mm Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I 04 ATEX 1248 60 V DC / 30 V AC No Yes

5/154

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP digital electronic modules and terminal modules

Technical specifications (continued)


Order No. Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module without packing Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. No-load voltage Uao (DC) Internal resistor Ri Trend key points E Voltage Ue (DC) Current Ie Output delay with resistive load "0" to "1", max. "1" to "0", max. Parallel switching of 2 outputs for increased power Switching frequency with resistive load, max. with inductive load, max. Ex(i) characteristics Max. values of output circuits (per channel) Ta (permissible ambient temperature), max. Parameter Remark Diagnosis: wire break Diagnosis: short circuit Behavior on CPU/Master STOP, channel-wise Status information/ alarms/diagnostics Alarms Alarms Diagnostic alarm Diagnoses Diagnostic functions Diagnostic information readable Wire break Short circuit Yes Yes Yes; R > 10 kohms, I < 100 A Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) Yes Yes Yes Yes Yes Yes Yes Yes Yes; R > 10 kohms, I < 100 A Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) Yes Yes Yes No Yes Yes yes yes yes yes yes yes 14 bytes yes yes yes 70 C 70 C 70 C 100 Hz 2 Hz 100 Hz 2 Hz 100 Hz 2 Hz No; for Ex reasons not possible; nor for predecessor Yes Yes 2 ms 1.5 ms 2 ms 1.5 ms 2 ms 1.5 ms 17.1 V 20 mA 13.2 V 27 mA 11 V 40 mA; 80 mA when outputs connected in parallel 4; additionally 1 intrinsically safe input for "H" shutdown 200 m 200 m 23.1 V 275 4; additionally 1 intrinsically safe input for "H" shutdown 200 m 200 m Yes 17.4 V 150 4; additionally 1 intrinsically safe input for "H" shutdown 200 m 200 m Yes 17.4 V 2 Byte 2 Byte 2 Byte 340 mA; with actuator supply 300 mA 10 mA 2.1 W 400 mA; with actuator supply 10 mA 2.8 W 6ES7 132-7RD01-0AB0 6ES7 132-7RD11-0AB0 6ES7 132-7RD21-0AB0

from backplane bus 3.3 V DC, max. 10 mA 2.5 W

Short-circuit protection of the output Yes; Ex i function

Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Yes Yes

Siemens IK PI 2009

5/155

Siemens AG 2008

ET 200iSP

SIMATIC ET 200 distributed I/Os

ET 200iSP digital electronic modules and terminal modules

Technical specifications (continued)


Order No. Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Current consumption from load voltage L+ (without load), max. Power loss, typ. Address area Address space per module without packing Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. No-load voltage Uao (DC) Internal resistor Ri Trend key points E Voltage Ue (DC) Current Ie Output delay with resistive load "0" to "1", max. "1" to "0", max. Parallel switching of 2 outputs for increased power Switching frequency with resistive load, max. with inductive load, max. Ex(i) characteristics Max. values of output circuits (per channel) Ta (permissible ambient temperature), max. Parameter Remark Diagnosis: wire break Diagnosis: short circuit Behavior on CPU/Master STOP, channel-wise 14 bytes yes yes 14 bytes yes yes yes 14 bytes yes yes yes 70 C 70 C 70 C 100 Hz 2 Hz 100 Hz 2 Hz 100 Hz 2 Hz No Yes Yes 2 ms 1.5 ms 2 ms 1.5 ms 2 ms 1.5 ms 17.1 V 20 mA 13.2 V 27 mA; 54 mA when outputs connected in parallel 40 mA; 80 mA when outputs connected in parallel 200 m 200 m 23.1 V 4; additionally 1 intrinsically safe input for "L" shutdown 200 m 200 m Yes; Ex i function 17.4 V 150 4; additionally 1 intrinsically safe input for "L" shutdown 200 m 200 m Yes; Ex i function 17.4 V 150 2 Byte 2 Byte 2 Byte 255 g 6ES7 132-7GD00-0AB0 340 mA; with actuator supply 255 g 6ES7 132-7GD10-0AB0 300 mA; with actuator supply 10 mA 2.1 W 255 g 6ES7 132-7GD20-0AB0 400 mA; with actuator supply 10 mA 2.8 W 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant 6ES7 132-7RD01-0AB0 6ES7 132-7RD11-0AB0 6ES7 132-7RD21-0AB0

from backplane bus 3.3 V DC, max. 10 mA 2.5 W

Short-circuit protection of the output Ex i function

5/156

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP digital electronic modules and terminal modules

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostic functions Diagnostic information readable Wire break Short circuit Yes Yes Yes; R > 10 kohms, I < 100 A Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) Yes Yes Yes Yes Yes; R > 10 kohms, I < 100 A Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) Yes Yes Yes Yes 6ES7 132-7GD00-0AB0 6ES7 132-7GD10-0AB0 6ES7 132-7GD20-0AB0

Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 275 g 275 g 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm No No 04 ATEX 2242 No No 04 ATEX 2242 255 g 6ES7 193-7CA00-0AA0 255 g 6ES7 193-7CA10-0AA0 255 g 6ES7 193-7CB00-0AA0 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I not relevant

Siemens IK PI 2009

5/157

Siemens AG 2008

ET 200iSP
Ordering data

SIMATIC ET 200 distributed I/Os

ET 200iSP digital electronic modules and terminal modules


Order No. Accessories ET 200iSP manual 6ES7 131-7RF00-0AB0 German English Connectors 6ES7 132-7RD01-0AB0 6ES7 132-7RD11-0AB0 6ES7 132-7RD21-0AB0 PROFIBUS connector with active terminating resistor For RS 485-IS circuit; 1.5 Mbit/s RS 485-IS coupler Isolating transformer for coupling of PROFIBUS DP and PROFIBUS RS 485-IS Labeling sheet 6ES7 132-7GD00-0AB0 6ES7 132-7GD10-0AB0 6ES7 132-7GD20-0AB0 DIN A4, perforated, each consisting of 10 sheets of 30 strips each, used for electronic modules and 20 strips, used for IM 151 petrol red yellow 6ES7 132-7HB00-0AB0 light beige Labels, inscribed 6ES7 193-7CA00-0AA0 Ordering unit 1 set with 200 units each for slot numbering 10 x slots 1 to 2 5 x slots 1 to 40 6ES7 193-7CA10-0AA0 Labels, blank Ordering unit 1 set with 200 units each for slot numbering S7-300 mounting rails 6ES7 193-7CB00-0AA0 Standard rail 585 mm Standard rail 885 mm 6ES7 390-1AF85-0AA0 6ES7 390-1AJ85-0AA0 8WA8 861-0AB 8WA8 861-0AC 8WA8 848-2AY 6ES7 193-7BH00-0AA0 6ES7 193-7BD00-0AA0 6ES7 193-7BB00-0AA0 6ES7 193-7BA00-0AA0 6ES7 972-0AC80-0XA0 6ES7 972-0DA60-0XA0 6ES7 152-1AA00-8AA0 6ES7 152-1AA00-8BA0 Order No.

Digital input modules 8 x DI Namur Digital input module 8 DI NAMUR Digital output modules for EEX i 4 x DO; 1 additional intrinsically safe input for "H" shut-off Digital output module 4 DO DC 23.1 V/20 mA Digital output module 4 DO DC 17.4 V/27 mA Digital output module 4 DO DC 17.4 V/40 mA 4 x DO; 1 additional intrinsically safe input for "L" shut-off Digital output module 4 DO DC 23.1 V/20 mA Digital output module 4 DO DC 17.4 V/27 mA

Digital output module 4 DO DC 17.4 V/40 mA Digital output modules for EEX e Digital output module 2 DO relay, 60 V UC, 2 A Terminal module TM-EM/EM60S For accommodating all electronic modules except 2 DO relay; screw-type terminals TM-EM/EM60C For accommodating all electronic modules except 2 DO relay; spring-loaded terminals TM-RM/RM 60S zur Aufnahme von Digitalausgabemodul 2 DO Relais und Reservemodulen; Schraubanschluss

5/158

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP digital electronic modules and terminal modules

Ordering data
Accessories (continued) Stainless steel enclosure IP66 for hazardous zone 1 in protection class EEx e Empty enclosure without installation of modules, for use in gaseous area, IP65 (IP54 when using a breather gland) Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) Empty enclosure without installation of modules, for use in dusty area, IP65 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units)

Order No. Accessories (continued) Enclosure with installation of ET 200iSP modules for use in gaseous area, IP65 (IP54 when using a breather gland); ET 200iSP components must be ordered separately 6DL2 804-0AD30 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) Enclosure with installation of modules, for use in dusty area, IP65; the ET 200iSP components must be ordered separately 6DL2 804-0DD30 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units)

Order No.

6DL2 804-1AD30

6DL2 804-1AD50

6DL2 804-0AD50

6DL2 804-1AE30

6DL2 804-0AE30

6DL2 804-1AE50

6DL2 804-0AE50

6DL2 804-1DD30

6DL2 804-0DD50

6DL2 804-1DD50

6DL2 804-0DE30

6DL2 804-1DE30

6DL2 804-0DE50

6DL2 804-1DE50

Siemens IK PI 2009

5/159

Siemens AG 2008

ET 200iSP
Overview

SIMATIC ET 200 distributed I/Os

ET 200iSP analog electronic modules and terminal modules

The electronic modules are plugged into the associated terminal modules that must be ordered separately (with screw-type or spring-loaded terminals) When plugged in, the modules are automatically uniquely coded mechanically Modules can be replaced under potentially explosive conditions during runtime

Technical specifications

Order No. Voltages and currents Voltage supply to the transducers short-circuit proof Feed current, max. Current consumption from supply voltage L+, max. Power loss, typ. Analog inputs Number of analog inputs cable length, shielded, max. permissible input current for current input (destruction limit), max. Cycle time (all channels), max.

6ES7 134-7SD00-0AB0

6ES7 134-7SD51-0AB0

6ES7 134-7TD00-0AB0

6ES7 134-7TD50-0AB0

Yes 23 mA; per channel 30 mA 0.4 W 4 50 m 22 mA 0.4 W 4 500 m 320 mA 2.7 W 4 500 m 90 mA Number of active channels per module x basic conversion time Yes Number of active channels per module x basic conversion time Yes Number of active channels per module x basic conversion time Yes 30 mA 0.4 W 4 500 m 50 mA Number of active channels per module x basic conversion time Yes

technical unit for temperature measurement, adjustable Input ranges (rated values), voltages Voltage -80 mV to +80 mV Input resistance (-80 mV to +80 mV) Input ranges (rated values), currents Current 4 to 20 mA

Yes Yes 1 000 k

Yes Yes

Yes Yes; min. 295 ohms

5/160

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP analog electronic modules and terminal modules

Technical specifications (continued)


Order No. Input ranges (rated values), thermoelements thermocouple Type B Input resistance (Type B) Type C Input resistance (Type C) Type E Input resistance (Type E) Type J Input resistance (type J) Type K Input resistance (Type K) Type L Input resistance (Type L) Type N Input resistance (Type N) Type R Input resistance (Type R) Type S Input resistance (Type S) Type T Input resistance (Type T) Type U Input resistance (Type U) Input ranges (rated values), resistors Impedance 0 to 600 Ohm Input resistance (0 to 600 Ohm) Input ranges (rated values), resistance thermometers Resistance thermometer Ni 100 Input resistance (Ni 100) Pt 100 Input resistance (Pt 100) Characteristic curve linearization programmable for thermoresistor Temperature compensation external temperature compensation with compensations socket Yes 6ES7 134-7SD00-0AB0 6ES7 134-7SD51-0AB0 6ES7 134-7TD00-0AB0 6ES7 134-7TD50-0AB0

Yes Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k Yes 1 000 k

Yes Yes 1 000 k

Yes Yes 2 000 k Yes 2 000 k Yes yes

internal temperature compensation Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, parameterizable Basic conversion time, including integration time, ms additional conversion time for wire break monitoring Interference voltage suppression for interference frequency f1 in Hz

Yes; via temperature value, acquired by an analog module of the same ET 200iSP station Yes; via supplied TC sensor module integrating (Sigma-Delta) integrating (Sigma-Delta) integrating (Sigma-Delta) integrating (Sigma-Delta)

16 Bit Yes 80 ms at 50 Hz; 66 ms at 60 Hz 5 50 / 60 Hz

16 Bit Yes 80 ms at 50 Hz; 66 ms at 60 Hz 5 50 / 60 Hz

13 Bit No

12 Bit; + sign Yes 30

50 / 60 Hz

50 / 60 Hz

Siemens IK PI 2009

5/161

Siemens AG 2008

ET 200iSP

SIMATIC ET 200 distributed I/Os

ET 200iSP analog electronic modules and terminal modules

Technical specifications (continued)


Order No. Smoothing of measured values parameterizable Level: none Level: weak Level: middle Level: strong Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection Burden of 2-wire transmitter, max. Errors/accuracies Crosstalk between the inputs, min. -50 db -50 db -50 db -50 db Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 70 db (peak value of interference < rated value of input range), min. common mode voltage, min. 90 db Status information/ alarms/diagnostics Alarms Diagnostic alarm Limit value alarm Diagnoses Diagnostic information readable Wire break Short circuit Group error Diagnostics indication LED Collective error SF (red) Isolation Isolation, analog inputs between the channels between the channels and the backplane bus between the channels and the load voltage L+ Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 230 g 230 g 230 g 230 g 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm 30 mm 129 mm 136.5 mm Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I 04 ATEX 1246 Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I 04 ATEX 1247 Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I 04 ATEX 1244 Yes II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I 04 ATEX 1245 Yes; functional Yes No Yes Yes No Yes No Yes Yes; Parameterizable Yes; parameterizable Yes Yes Yes Yes Yes Yes Yes Yes Yes; Parameterizable Yes; parameterizable Yes Yes Yes Yes; Parameterizable Yes; parameterizable Yes Yes Yes Yes Yes Yes Yes 750 6ES7 134-7SD00-0AB0 Yes; in 4 stages Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes; 64x cycle time 6ES7 134-7SD51-0AB0 Yes; in 4 stages Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes; 64x cycle time 6ES7 134-7TD00-0AB0 Yes; in 4 stages Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes; 64x cycle time 6ES7 134-7TD50-0AB0 Yes; in 4 stages Yes; 1x cycle time Yes; 4x cycle time Yes; 32x cycle time Yes; 64x cycle time

70 db

70 db

70 db

90 db

Yes

Yes

Yes

5/162

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP analog electronic modules and terminal modules

Technical specifications (continued)


Order No. Current consumption from load voltage1L+, max. Power loss, max. Analog outputs Number of analg outputs cable length, shielded, max. Output ranges, current 4 to 20 mA Connection of actuators for current output 2-conductor connection Load impedance (in rated range of output) with current outputs, max. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Settling time for resistive load for capacitive load for inductive load Errors/accuracies Crosstalk between the outputs, min. -50 db 4 500 m Yes Yes 330 mA 2.7 W 6ES7 135-7TD00-0AB0 Order No. Status information/ alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Diagnoses Diagnostic information readable Wire break Short circuit Diagnostics indication LED Collective error SF (red) Isolation 750 Isolation, analog outputs between the channels between the channels and the backplane bus Standards, approvals, certificates 14 Bit Type of protection to KEMA Dimensions Dimensions 4 ms 40 ms 40 ms Width Height Depth Weights Weight, approx. Order No. Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 275 g Order No. Accessories 6ES7 134-7TD00-0AB0 6ES7 134-7TD50-0AB0 6ES7 134-7SD51-0AB0 6ES7 134-7SD00-0AB0 6ES7 135-7TD00-0AB0 6ES7 193-7CA00-0AA0 ET 200iSP manual German English Connectors PROFIBUS connector with active terminating resistor For RS 485-IS circuit; 1.5 Mbit/s RS 485-IS coupler Isolating transformer for coupling of PROFIBUS DP and PROFIBUS RS 485-IS Labels, blank Ordering unit 1 set with 200 units each for slot numbering Siemens IK PI 2009 6ES7 152-1AA00-8AA0 6ES7 152-1AA00-8BA0 6ES7 972-0DA60-0XA0 275 g 340 g Order No. 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm No No 04 ATEX 2242 No No 04 ATEX 2242 Yes 6ES7 193-7CA00-0AA0 6ES7 193-7CA10-0AA0 265 g 6ES7 193-7CB00-0AA0 30 mm 129 mm 136.5 mm 04 ATEX 1250 No Yes Yes Yes Yes Yes Yes Yes 6ES7 135-7TD00-0AB0

Ordering data
Analog input modules 4 AI I 2WIRE HART 4 AI I 4WIRE HART 4 AI RTD 4 AI TC Analog output modules 4 AO I HART Terminal module TM-EM/EM60S Terminal module E60S (screw-type terminal) TM-EM/EM60C Terminal module E60C (spring-loaded terminal)

6ES7 972-0AC80-0XA0

6ES7 193-7CA10-0AA0

8WA8 848-2AY

5/163

Siemens AG 2008

ET 200iSP
Ordering data

SIMATIC ET 200 distributed I/Os

ET 200iSP analog electronic modules and terminal modules


Order No. Accessories (continued) Enclosure with installation of ET 200iSP modules for use in gaseous area, IP65 (IP54 when using a breather gland); ET 200iSP components must be ordered separately Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) 6DL2 804-0AD30 Enclosure with installation of modules, for use in dusty area, IP65; the ET 200iSP components must be ordered separately Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units) 6DL2 804-1DD30 6DL2 804-1AD30 Order No.

Accessories (continued) Labeling sheet DIN A4, perforated, each consisting of 10 sheets of 30 strips each, used for electronic modules and 20 strips, used for IM 151 petrol red yellow light beige Labels, inscribed Ordering unit 1 set with 200 units each for slot numbering 10 x slots 1 to 2 5 x slots 1 to 40 S7-300 mounting rails Standard rail 585 mm Standard rail 885 mm Stainless steel enclosure IP66 for hazardous zone 1 in protection class EEx e Empty enclosure without installation of modules, for use in gaseous area, IP65 (IP54 when using a breather gland) Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) Empty enclosure without installation of modules, for use in dusty area, IP65 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units) 6ES7 390-1AF85-0AA0 6ES7 390-1AJ85-0AA0 8WA8 861-0AB 8WA8 861-0AC 6ES7 193-7BH00-0AA0 6ES7 193-7BD00-0AA0 6ES7 193-7BB00-0AA0 6ES7 193-7BA00-0AA0

6DL2 804-1AD50

6DL2 804-1AE30

6DL2 804-1AE50

6DL2 804-0AD50

6DL2 804-0AE30

6DL2 804-1DD50

6DL2 804-1DE30

6DL2 804-0AE50

6DL2 804-1DE50

6DL2 804-0DD30

6DL2 804-0DD50

6DL2 804-0DE30

6DL2 804-0DE50

5/164

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP watchdog module and terminal modules

Overview
The watchdog module will be plugged onto the (to be ordered separately) associated terminal module (screw connection or spring-loaded connection). Modules can be replaced under potentially explosive conditions during runtime.

Ordering data
Watchdog module Terminal modules TM-EM/EM60S Terminal module E60S (screw-type terminal) TM-EM/EM60C Terminal module E60S (spring-loaded terminal) Accessories ET 200iSP product manual German English Connectors PROFIBUS connector with active termination resistor For RS485-IS circuit; 1.5 Mbit/s RS 485-IS Coupler Isolating transformer for coupling from PROFIBUS DP and PROFIBUS RS 485-IS

Order No. 6ES7 138-7BB00-0AB0 6ES7 193-7CA00-0AA0 Accessories (continued) Labeling sheet DIN A4, perforated, each consisting of 10 sheets of 30 strips each, used for electronic modules and 20 strips, used for IM 151 petrol red yellow light beige 6ES7 152-1AA00-8AA0 6ES7 152-1AA00-8BA0 6ES7 972-0DA60-0XA0 Labels, inscribed Ordering unit 1 set with 200 pieces each for slot numbering 10 x slots 1 to 2 5 x slots 1 to 40 Labels, blank 6ES7 972-0AC80-0XA0 Ordering unit 1 set with 200 pieces each for slot numbering S7-300 mounting rail Standard Rail 585 mm Standard Rail 885 mm

Order No.

5
6ES7 193-7BH00-0AA0 6ES7 193-7BD00-0AA0 6ES7 193-7BB00-0AA0 6ES7 193-7BA00-0AA0

6ES7 193-7CA10-0AA0

8WA8 861-0AB 8WA8 861-0AC 8WA8 848-2AY

6ES7 390-1AF85-0AA0 6ES7 390-1AJ85-0AA0

Siemens IK PI 2009

5/165

Siemens AG 2008

ET 200iSP
Ordering data

SIMATIC ET 200 distributed I/Os

ET 200iSP watchdog module and terminal modules


Order No. Accessories (continued) Enclosure with installation of ET 200iSP modules for use in gaseous area, IP65 (IP54 when using an air-conditioning nozzle), ET 200iSP components must be ordered separately 6DL2 804-0AD30 Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 66) Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 111) Enclosure with installation of modules, for use in dusty area, IP65, the ET 200iSP components must be ordered separately 6DL2 804-0DD30 Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 66) Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 111) 6DL2 804-1DD30 6DL2 804-1AD30 Order No.

Accessories (continued) Stainless steel enclosure IP66 for Ex-Zone 1 in protection class EEx e, Empty housing without installation of modules, for use in gaseous area, IP65 (IP54 when using an air-conditioning nozzle) Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 66) Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable glands (total 111) Empty housing without installation of modules, for use in dusty area, IP65 Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 41) and 2 rows of blanking plugs Wall housing 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 66) Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable glands (total 68) and 2 rows of blanking plugs Wall housing 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable glands (total 111)

6DL2 804-1AD50

6DL2 804-0AD50

6DL2 804-1AE30

6DL2 804-0AE30

6DL2 804-1AE50

6DL2 804-0AE50

6DL2 804-0DD50

6DL2 804-1DD50

6DL2 804-0DE30

6DL2 804-1DE30

6DL2 804-0DE50

6DL2 804-1DE50

5/166

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP reserve module and terminal modules

Overview

Ordering data
Reserve module Terminal module TM-EM/EM60S Terminal module E60S (screw-type terminal) TM-EM/EM60C Terminal module E60C (spring-loaded terminal) TM-RM/RM 60S For accommodating digital output module 2 DO relay and reserve modules; screw-type terminal Accessories ET 200iSP manual German English

Order No. 6ES7 138-7AA00-0AA0 6ES7 193-7CA00-0AA0

6ES7 193-7CA10-0AA0

6ES7 193-7CB00-0AA0

6ES7 152-1AA00-8AA0 6ES7 152-1AA00-8BA0 6ES7 972-0DA60-0XA0

The reserve module is plugged onto the relevant terminal module (to be ordered separately; screw-type or springloaded connection). Modules can be replaced under potentially explosive conditions during runtime.

Connectors PROFIBUS connector with active terminating resistor For RS 485-IS circuit; 1.5 Mbit/s RS 485-IS coupler Isolating transformer for coupling of PROFIBUS DP and PROFIBUS RS 485-IS Labeling sheet DIN A4, perforated, each consisting of 10 sheets of 30 strips each, used for electronic modules and 20 strips, used for IM 151 petrol red yellow 6ES7 193-7BH00-0AA0 6ES7 193-7BD00-0AA0 6ES7 193-7BB00-0AA0 6ES7 193-7BA00-0AA0 6ES7 972-0AC80-0XA0

Technical specifications
Order No. Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. 180 g 6ES7 1937CA000AA0 No No 04 ATEX 2242 6ES7 1937CA100AA0 No No 04 ATEX 2242 6ES7 1937CB000AA0 Yes 30 mm 129 mm 136.5 mm Yes II2 G EEx ib IIC T4 04 ATEX 1251 6ES7 138-7AA00-0AA0

light beige Labels, inscribed Ordering unit 1 set with 200 units each for slot numbering 10 x slots 1 to 2 5 x slots 1 to 40 Labels, blank Ordering unit 1 set with 200 units each for slot numbering S7-300 mounting rails Standard rail 585 mm Standard rail 885 mm

8WA8 861-0AB 8WA8 861-0AC 8WA8 848-2AY

Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 275 g 275 g 340 g 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm 60 mm 190 mm 52 mm

6ES7 390-1AF85-0AA0 6ES7 390-1AJ85-0AA0

Siemens IK PI 2009

5/167

Siemens AG 2008

ET 200iSP
Ordering data

SIMATIC ET 200 distributed I/Os

ET 200iSP reserve module and terminal modules


Order No. Accessories (continued) Enclosure with installation of ET 200iSP modules for use in gaseous area, IP65 (IP54 when using a breather gland); ET 200iSP components must be ordered separately 6DL2 804-0AD30 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) Enclosure with installation of modules, for use in dusty area, IP65; the ET 200iSP components must be ordered separately 6DL2 804-0DD30 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units) 6DL2 804-1DD30 6DL2 804-1AD30 Order No.

Accessories (continued) Stainless steel enclosure IP66 for hazardous zone 1 in protection class EEx e Empty enclosure without installation of modules, for use in gaseous area, IP65 (IP54 when using a breather gland) Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in gaseous area, with 5 rows of M16 cable entries (111 units) Empty enclosure without installation of modules, for use in dusty area, IP65 Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (41 units) and 2 rows of blanking plugs Wall enclosure 650 x 450 x 230, for installation of max. 15 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (66 units) Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 3 rows of M16 cable entries (68 units) and 2 rows of blanking plugs Wall enclosure 950 x 450 x 230, for installation of max. 25 ET 200iSP modules, for use in dusty area, with 5 rows of M16 cable entries (111 units)

6DL2 804-1AD50

6DL2 804-0AD50

6DL2 804-1AE30

6DL2 804-0AE30

6DL2 804-1AE50

6DL2 804-0AE50

6DL2 804-0DD50

6DL2 804-1DD50

6DL2 804-0DE30

6DL2 804-1DE30

6DL2 804-0DE50

6DL2 804-1DE50

5/168

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

ET 200iSP supply unit

Overview

Technical specifications
Order No. Voltages and currents Mains/voltage failure jumpering, min. Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from supply voltage L+, max. Power loss, typ. Ex(i) characteristics Max. values of input circuits (per channel) Um (fault voltage), max. AC Status information/ alarms/diagnostics Status indicator Alarms Alarms Diagnoses Diagnostic information readable Diagnostics indication LED Collective error SF (red) Isolation tested with between all secondary voltages between supply voltage and all secondary voltages Isolation primary/secondary between supply voltage and electronics Standards, approvals, certificates CE symbol Type of protection to EN 50020 (CENELEC) Type of protection to KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 2 700 g 60 mm 190 mm 136.5 mm Yes Ex de [ib]IIC T4 04 ATEX 2263 Yes No no electrical isolation 600V DC No Yes; via IM 152 No Yes 4A 20 W 24 V Yes 0.25 ms; for powerbus and backplane bus 15ms for IM 152 6ES7 138-7EA01-0AA0

The power supply (PS) is plugged into the associated terminal module TM-PS-A or TM-PS-B (with redundancy; to be ordered separately). The power supply unit fulfills the following functions: It provides reliable isolated power supply for the ET 200iSP with the necessary operating voltages for - logic (through the backplane bus) - PROFIBUS DP interface of IM 152-1 - powerbus (for supplying the electronic modules) Takes over the safety limit of the output voltage Has an explosion-proof metal enclosure (explosion protection EEx d) Can be redundantly configured

Siemens IK PI 2009

5/169

Siemens AG 2008

ET 200iSP

SIMATIC ET 200 distributed I/Os

ET 200iSP supply unit

Technical specifications (continued)


Order No. Standards, approvals, certificates CE symbol Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx. 235 g 235 g 60 mm 190 mm 52 mm 60 mm 90 mm 52 mm Yes 04 ATEX 2242 Yes 04 ATEX 2242 6ES7 1937DA10-0AA0 6ES7 1937DB10-0AA0

Ordering data
Power supply module PS Terminal module TM-PS-A Standard Terminal module TM-PS-B for redundant operation

Order No. 6ES7 138-7EA01-0AA0 6ES7 193-7DA10-0AA0 6ES7 193-7DB10-0AA0

5/170

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200iSP

RS 485-IS Coupler

Overview
Coupler for conversion from PROFIBUS DP to PROFIBUS RS 485-IS intrinsically safe (Intrinsically Safe i type of protection) Required to connect intrinsically safe PROFIBUS DP stations (e.g. ET 200iS, ET 200iSP) and all third party devices which have an Ex i DP interface Can also be implemented as a repeater in hazardous areas Acts as a safety barrier Passive bus stations, configuration is not necessary Certification according to ATEX 100a

Technical specifications
Dimensions and weight Dimensions W x H x D (mm) Weight Technical specifications General Degree of protection Ambient temperature Standards and approvals PROFIBUS EU directive CENELEC UL and CSA IEC 61784-1: 2002 Ed1 CP 3/1 94/9/EG (ATEX 100a) II 3 (2) G EEx nA[ib] IIC T4 Class I, Division2, Group A, B, C, D T4 Class I Zone 2, Group IIC T4 AIS Class I, Divison 1, Group A, B, C, D [Aexib] IIC, Class I, Zone1, 2, Group IIC Class I, Division2, Group A, B, C, D T4 Class I Zone 2, Group IIC T4 AIS Class I, Divison 1, Group A, B, C, D [Aexib] IIC, Class I, Zone1, 2, Group IIC IEC61131-2, Part 2 Conforming with 89/336/EWG Conforming with 73/23/EWG Classification companies ABS (American Bureau of Shipping) BV (Bureau Veritas) DNV (Det Norske Veritas) GL (Germanischer Lloyd) LRD (Lloyds Register of Shipping) Class NK (Nippon Kaiji Kyokai) 9.6; 19.2; 45.45; 93.75; 187.5; 500 kbit/s 1.5 Mbit/s PROFIBUS DP IP20 - 20 C + 60 C 80 x 125 x 130 Approx. 500 g Voltages, currents, potentials Nominal supply voltage for RS 485-IS coupler Polarity reversal protection Voltage drop bypass Potential isolation for 24 V power supply to PROFIBUS DP - tested with to PROFIBUS RS 485-IS - tested with Current consumption RS 485-IS coupler (24 V DC), max. Power loss of the module, typically Status, alarms, diagnostics Status display Alarms Diagnostic functions Bus monitoring PROFIBUS DP (primary) Bus monitoring PROFIBUS RS 485-IS (secondary) Monitoring 24 V power supply Technical safety notice VDC ISC P0 Vmax LI Ci Um Ta RS 485-IS segment Permitted cable length on a single line 9,6 ... 187.5 kbit/s 500 kbit/s 1.5 Mbit/s Number of PROFIBUS DP nodes that can be connected, max. PROFIBUS RS 485-IS bus termination switch RS 485-IS 1,000 m 400 m 200 m 31 DP Ex i 200 m 200 m 200 m 16 4.2 V 93 mA 0.1 Watts 4.2 V 0 0 250 V AC 25 ... +60 C No None Yes Yellow LED "DP1" Yellow LED "DP2" Green LED "ON" Yes 500 V DC Yes 500 V AC 150 mA 3 Watts 24 V DC (20.4 28.8 V) Yes Min. 5 ms

FM

IEC CE Ship-building certification

Module-specific specifications Data transmission rate on PROFIBUS DP, PROFIBUS RS 485-IS Bus protocol

integrated, can be added

Siemens IK PI 2009

5/171

Siemens AG 2008

ET 200iSP
Ordering data

SIMATIC ET 200 distributed I/Os

RS 485-IS Coupler
Order No. 6ES7 972-0AC80-0XA0

RS 485-IS segment Isolating transition for coupling PROFIBUS DP to PROFIBUS RS 485-IS Accessories PROFIBUS connector with passive terminating resistance PROFIBUS connector with active terminating resistor For RS 485-IS circuit; 1.5 Mbit/s PROFIBUS plug connector For the intrinsically safe PROFIBUS, 1.5 Mbit/s Sectional rail 160 mm 482 mm 530 mm 830 mm

6ES7 972-0DA30-0XA0 6ES7 972-0DA60-0XA0

6ES7 972-0BA30-0XA0

6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 6XV1 830-0EH10

2000 mm PROFIBUS Fast Connect bus line Standard type specially designed for snap-on mounting, 2-core, shielded, sold by the meter; maximum length supplied 1000 m, minimum order 20 m

5/172

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro
Introduction

Overview

Design
The tried and tested separation of module and bus/power connection technology, which has already been used for the ET 200eco, is now also used for the digital and analog expansion modules of the ET 200pro. For the interface module this allows use of the T-functionality for the bus and 24 V power supply, and for the expansion modules it permits pre-wiring of sensor/ actuator connections. This permanent wiring allows exactly one electronics module to be hot-swapped in the event of a fault without having to switch off the whole station. It can continue to operate fault-free while the module is being replaced. This ensures very high plant availability. When an electronics component is replaced, the whole I/O wiring can remain on the connecting module and does not have to be marked or removed. Modules The modules of the ET 200pro usually have two or three components. Interface and power modules as well as digital and analog expansion modules comprise: one bus connector which constitutes the backplane bus of the system one electronics module or interface module one connecting module A backplane bus module is required for operation of motor starters. A station is constructed from: one rack one interface module for PROFIBUS DP one connecting module for the interface module for PROFIBUS DP - CM IM DP direct with up to six M20 screwed cable glands - CM IM DP ECOFAST Cu - CM IM DP M12 7/8 Or optionally each with an interface module for PROFINET IO a terminal module for the PROFINET IO interface module: - CM IM PN M12 7/8 - CM IM PN 2 x RJ45 - CM IM PN 2 x SCRJ FO max. 16 expansion modules that can be mounted in stations up to 1 m in width Expansion modules The following expansion modules are available: Digital I/Os Analog inputs Analog outputs Connecting modules IO - CM IO 8 x M8 for digital electronic modules - CM IO 4 x M12 inverse for digital electronic modules - CM IO 4x M12 for digital or analog electronic modules - CM IO 8x M12 for digital electronic modules Power module electronics Connecting modules for power modules - CM PM-E PP (Push Pull) - CM PM-E directly with up to two M20 screwed cable glands - CM PM-E ECOFAST Cu - CM PM-E 7/8 Motor starter

Distributed I/O system with degree of protection IP65/67 for cabinet-free use at the machine. Small, multifunctional complete solution: Digital inputs/outputs, failsafe modules, motor starters up to 5.5 kW, etc. Communication over PROFIBUS or PROFINET Mixed arrangement of failsafe and standard modules in the same station Freely selectable connection technique: Direct, ECOFAST or M12 7/8" Power module for easy implementation of load groups Module replacement during operation (hot swapping) Easy installation as well as permanent wiring Data transmission rates of up to 12 Mbit/s Extensive diagnostics: Module-specific or channel-specific Intelligent motor starters for starting and protection of motors and loads up to 5.5 kW - Versions: Direct and reversing starters Standard and High-Feature Failsafe modules with safety-related signal processing according to PROFIsafe

Application
SIMATIC ET 200pro is the new modular I/O system with high degree of protection IP65/66/67 for local, cabinetless applications. ET 200pro distinguishes itself through a small frame size and an innovative installation concept. ET 200pro can be optimized and very flexibly adapted to the requirements of the corresponding automation task with respect to the connection method, required I/Os and fieldbus connection. New features such as the integrated PROFIsafe safety technology, the PROFINET interface and the ability to hotswap modules permit it to be used for a wide range of applications. With the integrated motor starters, conveyor applications can be implemented optimally, or drives of up to 5.5 kW can be controlled without control cabinet.

Siemens IK PI 2009

5/173

Siemens AG 2008

ET 200pro
Introduction

SIMATIC ET 200 distributed I/Os

Design (continued)
Rack Two different racks are available for mounting the ET 200pro: Narrow rack The narrow rack supports complete pre-assembly on the workbench by means of two mounting flanges outside of the ET 200pro station.

Technical specifications
General technical specifications Electronic modules Digital inputs/outputs Analog inputs Analog outputs Motor starter Cables and connections M12 and M8 round connector with standard assignment for actuator/sensor 12 Mbit/s (PROFIBUS DP), 100 Mbit/s (PROFINET IO) 24 V DC 5A

Transmission rate, max. Supply voltage Current consumption of one ET 200pro (internal and encoder supply, non-switched voltage), up to 55 C, max.

10 A Current consumption of one ET 200pro per infeed (IM, PM, switched voltage, up to 55 C, max.)

5
Compact rack When the compact rack is used, the small footprint of the ET 200pro system can be used to best advantage.

For overall configuration with looping through (several ET 200pro), up to 55 C, max. Degree of protection Material Ambient conditions Temperature Relative humidity Atmospheric pressure Mechanical stress Vibrations

16 A (with connecting module, directly) IP65/66/IP67 for interface, digital and analog modules Thermoplastic (reinforced with glass fiber) from 0 55 C (-25 C on request) from 5 100% from 795 1080 hPa Vibration test conforming to IEC 60068, Part 2-6 (sinusoidal) Constant acceleration 5 g, occasionally 10 g for interface, digital and analog modules 2 g motor starters

Shock

Shock test according to IEC 680068 Part 2 - 27, half-sine, 30 g, 18 ms duration for interface, digital and analog modules 15 g, 11 ms duration for motor starters UL, CSA or cULus

Function
The SIMATIC ET 200pro is easily configured with STEP 7. A GSD file is available for interfacing with systems of other manufacturers.

Approvals

5/174

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-1 and IM 154-2 interface modules

Overview
Interface modules for handling communication between the ET 200pro and the higher-level master over PROFIBUS DP.

Technical specifications
Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) Short-circuit protection 24 V Yes; over exchangeable fuses Yes; against destruction Yes 28.8 V 24 V Yes; over exchangeable fuses Yes; against destruction Yes 20.4 V 28.8 V Swapping interrupt Hot swapping of modules Status information/ alarms/diagnostics Diagnostics indication LED Bus error BF (red) Collective error SF (red) Yes Yes Yes Yes Yes Yes 6ES7 1541AA00-0AB0 6ES7 1542AA00-0AB0 Order No. Process alarm 6ES7 1541AA00-0AB0 parameterizable parameterizable possible 6ES7 1542AA00-0AB0 parameterizable parameterizable possible

reverse polarity protection Rated value DC 24 V permissible range, upper limit (DC) Current consumption from supply voltage 1L+, max. Address area Adressing volume Outputs Inputs PROFIBUS DP automatic detection of transmission speed 1st interface Type of interface Physics Functionality DP slave DP slave Services - SYNC/FREEZE - direct data exchange (cross traffic) Transmission speeds, min. Transmission speeds, max. Parameter DPV1 operation Diagnostic alarm

permissible range, lower limit (DC) 20.4 V

Monitoring 24 V voltage supply ON Yes (green) Load voltage monitoring DC 24 V (green) Yes; integrated power module 500 VDC No Yes

200 mA

200 mA

Isolation Isolation checked with Isolation between backplane bus and electronics between supply voltage and electronics 500 VDC No Yes

244 Byte 244 Byte Yes

244 Byte 244 Byte Yes

Environmental requirements Operating termperature min. max. Storage/transport temperature min. -40 C 70 C Yes Yes Yes -40 C 70 C Yes Yes Yes max. Degree and class of protection IP 65 IP 66 IP 67 Dimensions Dimensions Width 90 mm 130 mm 59.3 mm 395 g 90 mm 130 mm 59.3 mm 415 g Height Depth Weights Weight, approx. -25 C 55 C -25 C 55 C

PROFIBUS DP RS 485 Yes

PROFIBUS DP RS 485 Yes

Yes Yes 9.6 kBit/s 12 MBit/s possible parameterizable

Yes Yes 9.6 kBit/s 12 MBit/s possible parameterizable

Siemens IK PI 2009

5/175

Siemens AG 2008

ET 200pro
Ordering data

SIMATIC ET 200 distributed I/Os

IM 154-1 and IM 154-2 interface modules


Order No. 6ES7 154-1AA00-0AB0 PROFIBUS ECOFAST hybrid cable GP, pre-assembled with 2 ECOFAST connectors, trailing-type cable 2 x CU 0.64 mm2 and 4 x Cu 1.5 mm2 1.5 m long 3.0 m long 5.0 m long 10 m long 15 m long 6ES7 194-4AA00-0AA0 20 m long 25 m long 30 m long 35 m long 6ES7 194-4AC00-0AA0 40 m long 45 m long 50 m long PROFIBUS ECOFAST hybrid cable, non-assembled 6ES7 194-4AD00-0AA0 Trailing-type cable 2 x CU 0.64 mm2 and 4 x Cu 1.5 mm2 50 m long 100 m long PROFIBUS ECOFAST hybrid cable GP, non-assembled Trailing-type cable 2 x CU 0.64 mm2 and 4 x Cu 1.5 mm2 50 m long 100 m long 6XV1 830-7BH15 6XV1 830-7BH30 6XV1 830-7BH50 6XV1 830-7BN10 6XV1 830-7BN15 6XV1 830-7BN20 6XV1 830-7BN25 6XV1 830-7BN30 6XV1 830-7BN35 6XV1 830-7BN40 6XV1 830-7BN45 6XV1 830-7BN50 PROFIBUS ECOFAST hybrid connector 180 ECOFAST Cu, 2 x Cu, 4 x 1.5 mm2,, HANBRID connector with male insert, 5 per pack with female insert, 5 per pack PROFIBUS ECOFAST hybrid connector angular ECOFAST Cu, 2 x Cu, 4 x 1.5 mm2,, HANBRID connector with male insert, 5 per pack with female insert, 5 per pack ECOFAST sealing cap for protecting unused bus connections for ET 200pro; 10 items per pack 6GK1 905-0CC00 6GK1 905-0CD00 6ES7 194-1JB10-0XA0 6GK1 905-0CA00 6GK1 905-0CB00 6XV1 860-4PN50 6XV1 860-4PT10 6XV1 830-7AN50 6XV1 830-7AT10 6XV1 860-3PH15 6XV1 860-3PH30 6XV1 860-3PH50 6XV1 860-3PN10 6XV1 860-3PN15 6XV1 860-3PN20 6XV1 860-3PN25 6XV1 860-3PN30 6XV1 860-3PN35 6XV1 860-3PN40 6XV1 860-3PN45 6XV1 860-3PN50 Order No.

IM 154-1 interface module for ET 200pro; for communication between ET 200pro and higherlevel masters over PROFIBUS DP IM 154-2 High Feature interface module for ET 200pro; for communication between ET 200pro and higherlevel masters over PROFIBUS DP; support of PROFIsafe Accessories CM IM DP ECOFAST connection module for connecting PROFIBUS DP and the 24 V power supply to PROFIBUS interface modules, 2 ECOFAST Cu connections CM IM DP direct connection module

6ES7 154-2AA00-0AB0

for connecting PROFIBUS DP and the 24 V power supply directly to the PROFIBUS interface modules, up to six M20 screwed cable glands CM IM DP M12, 7/8" connection module for connecting PROFIBUS DP and the 24 V power supply to PROFIBUS interface modules, 2 x M12 and 2 x 7/8" Accessories for CM IM DP ECOFAST PROFIBUS ECOFAST hybrid cable, pre-assembled with 2 ECOFAST connectors, trailing-type cable 2 x CU 0.64 mm2 and 4 x Cu 1.5 mm2 1.5 m long 3.0 m long 5.0 m long 10 m long 15 m long 20 m long 25 m long 30 m long 35 m long 40 m long 45 m long 50 m long

5/176

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-1 and IM 154-2 interface modules

Ordering data
Accessories for CM IM DP direct PROFIBUS trailing cable Max. acceleration 4 m/s2, at least 3,000,000 bending cycles, bending radius 60 mm, 2-core shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m PROFIBUS FC Food bus cable with PE sheath for use in the food and beverages industry, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m PROFIBUS FC Robust bus cable with PUR sheath for use under conditions of extreme mechanical stress and aggressive chemicals, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m Power line 5-core, 5 x 1.5 mm2, trailing type, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m Accessories for CM IM DP M12 7/8 PROFIBUS M12 connecting cable Pre-assembled with two M12 connectors, 5-pin 1.5 m long 2.0 m long 3.0 m long 5.0 m long 10 m long 15 m long 7/8" connecting cable to power supply 5-core, 5 x 1.5 mm2, trailing type, pre-assembled with two 7/8" connectors, 5-pin 1.5 m long 2.0 m long 3.0 m long 5.0 m long 10 m long 15 m long M12 cable connector for ET 200eco, with axial cable outlet with male insert, 5 per pack with female insert, 5 per pack 7/8" cable connector for ET 200eco, with axial cable outlet with male insert, 5 per pack with female insert, 5 per pack

Order No. M12 sealing cap 6XV1 830-3EH10 for protection of unused M12 connections with ET 200pro Sealing cap 7/8" for protecting unused 7/8" connections for ET 200pro; 10 items per pack 6XV1 830-0GH10 General accessories ET 200pro rack Narrow, for interface, electronics and power modules - 500 mm - 1000 mm - 2000 mm, can be cut to length Compact, for interface, electronics and power modules - 500 mm - 1000 mm - 2000 mm, can be cut to length Wide, for interface, electronics, power modules and motor starters - 500 mm - 1000 mm - 2000 mm, can be cut to length Wide, for I/O modules and motor starters - 500 mm - 1000 mm - 2000 mm 6XV1 830-3DH15 6XV1 830-3DH20 6XV1 830-3DH30 6XV1 830-3DH50 6XV1 830-3DN10 6XV1 830-3DN15 Spare fuse 12.5 A quick-response, for interface and power modules, 10 items per package unit Technical product data for CAX applications, one-off license Technical product data for CAX applications, one-off license, update service SIMATIC Manual Collection 6XV1 822-5BH15 6XV1 822-5BH20 6XV1 822-5BH30 6XV1 822-5BH50 6XV1 822-5BN10 6XV1 822-5BN15 Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No. 3RX9 802-0AA00

6ES7 194-3JA00-0AA0

6XV1 830-0JH10

6ES7 194-4GA00-0AA0 6ES7 194-4GA60-0AA0 6ES7 194-4GA20-0AA0

6ES7 194-4GC70-0AA0 6ES7 194-4GC60-0AA0 6ES7 194-4GC20-0AA0

6XV1 830-8AH10

5
6ES7 194-4GB00-0AA0 6ES7 194-4GB60-0AA0 6ES7 194-4GB20-0AA0

6ES7 194-4GD00-0AA0 6ES7 194-4GD10-0AA0 6ES7 194-4GD20-0AA0 6ES7 194-4HB00-0AA0

6ES7 991-0CD01-0YX0

6ES7 991-0CC00-0YX2

6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

6GK1 905-0EA00 6GK1 905-0EB00

6GK1 905-0FA00 6GK1 905-0FB00

Siemens IK PI 2009

5/177

Siemens AG 2008

ET 200pro
Overview

SIMATIC ET 200 distributed I/Os

IM 154-4 PN interface modules

Interface module for processing the communication between ET 200pro and a higher-level controller over PROFINET IO.

Technical specifications

Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) Short-circuit protection

6ES7 154-4AB10-0AB0

Order No. Status information/ alarms/diagnostics

6ES7 154-4AB10-0AB0

24 V Yes; Fuse in lower part is exchangeable, the fuse on the IM-LP is not Yes; against destruction Yes 28.8 V; Unit [ V]

Diagnostics indication LED Bus error BF (red) Collective error SF (red) Yes; Additional LEDs (MAINT, P1/2 LINK, P1/2 RX/TX) available Yes

reverse polarity protection Rated value DC 24 V permissible range, upper limit (DC) Current consumption from supply voltage 1L+, max.

Monitoring 24 V voltage supply ON Yes (green) Load voltage monitoring DC 24 V (green) Isolation Isolation checked with Isolation between backplane bus and electronics between supply voltage and electronics Environmental requirements Operating termperature min. max. Storage/transport temperature min. -40 C 70 C Yes Yes Yes 0x002A 0x0305 -25 C 55 C 500 VDC No Yes Yes

permissible range, lower limit (DC) 20.4 V; Unit [ V]

400 mA; Dependent on terminal module, typ. maximum value for FO connection method, full load on RWB and 20.4 V input voltage 6 W; Dependent on terminal module, typ. maximum value for CU connection method, full load on RWB, for FO the value is approx. 0.7 W higher

Power loss, typ.

Memory Type of storage Micro Memory Card Address area Adressing volume Outputs Inputs Protocols PROFINET IO PROFINET IO Transmission speed, max. automatic detection of transmission speed Services Isochronous mode Isochronouos mode equidistance shortest clock pulse No No 0.25 ms 100 MBit/s Yes ARP, PING, SNMP Yes 256 Byte 256 Byte No

max. Degree and class of protection IP 65 IP 66 IP 67 General information Vendor identification (VendorID) Device identifier (DeviceID) Dimensions Dimensions Width Height Depth Weights Weight, approx.

90 mm 130 mm 59.3 mm 490 g

5/178

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-4 PN interface modules

Ordering data
IM 154-4 PN High Feature interface module for communication between ET 200pro and higher-level controllers over PROFINET IO; support of PROFIsafe Accessories CM IM PN connection module M12, 7/8" for connecting PROFINET PN and 24 V power supply to PROFINET interface modules, 2 x M12 and 2 x 7/8" CM IM PN connection module 2xRJ45 for connecting PROFINET PN and 24 V power supply to PROFINET interface modules, 2 x RJ45 and 2 x push-pull power connector CM IM PN 2xSCRJ FO connection module for connecting PROFINET PN and 24 V power supply to PROFINET interface modules, 2 x SCRJ FO and 2 x push-pull power connector M12 sealing cap for protection of unused M12 connections with ET 200pro IE M12 connecting cables Pre-assembled, with two M12 connectors, up to 85 m 0.3 m long 0.5 m long 1.0 m long 1.5 m long 2.0 m long 3.0 m long 5.0 m long 10 m long 15 m long Other special lengths with 90 or 180 cable outlet

Order No. 6ES7 154-4AB10-0AB0 Accessories (continued) 7/8" connecting cable to power supply 5-core, 5 x 1.5 mm2, trailing type, pre-assembled with two 7/8" connectors, 5-pin, up to 50 m 1.5 m long 6ES7 194-4AJ00-0AA0 2.0 m long 3.0 m long 5.0 m long 10 m long 6ES7 194-4AF00-0AA0 15 m long Other special lengths with 90 or 180 cable outlet

Order No.

6XV1 822-5BH15 6XV1 822-5BH20 6XV1 822-5BH30 6XV1 822-5BH50 6XV1 822-5BN10 6XV1 822-5BN15 see http://support.automation. simens.com/WW/view/en/ 26999294 6XV1 830-8AH10

Power line 6ES7 194-4AG00-0AA0 5-core, 5 x 1.5 mm2, trailing type, sold by the meter, minimum order quantity 20 m, maximum order quantity 1,000 m 7/8" cable connector 3RX9 802-0AA00 for ET 200eco, with axial cable outlet with male insert, 5 per pack with female insert, 5 per pack 7/8" Power T-Tap Power T-piece with two 7/8 female inserts and one 7/8 male insert, 5 per pack Industrial Ethernet FastConnect installation cables IE FC TP Standard Cable GP 2 x 2; Sold by the meter, max. order quantity 1000 m; Minimum order quantity 20 m IE FC TP Trailing Cable 2 x 2; Sold by the meter, max. order quantity 1000 m; Minimum order quantity 20 m IE FC TP Trailing Cable GP 2 x 2; Sold by the meter, max. order quantity 1000 m; Minimum order quantity 20 m IE TP Torsion Cable GP 2 x 2; Sold by the meter, max. order quantity 1000 m; Minimum order quantity 20 m IE FC TP Marine Cable 2 x 2; Sold by the meter, max. order quantity 1000 m; Minimum order quantity 20 m

5
6GK1 905-0FA00 6GK1 905-0FB00 6GK1 905-0FC00

6XV1 870-8AE30 6XV1 870-8AE50 6XV1 870-8AH10 6XV1 870-8AH15 6XV1 870-8AH20 6XV1 870-8AH30 6XV1 870-8AH50 6XV1 870-8AN10 6XV1 870-8AN15 see http://support.automation. siemens.com/WW/view/en/ 26999294

6XV1 840-2AH10

6XV1 840-3AH10

6XV1 870-2D

6XV1 870-2F

6XV1 840-4AH10

Siemens IK PI 2009

5/179

Siemens AG 2008

ET 200pro
Ordering data

SIMATIC ET 200 distributed I/Os

IM 154-4 PN interface modules


Order No. General accessories ET 200pro rack 6GK1901-1BB10-6AA0 Narrow, for interface, electronics and power modules - 500 mm - 1000 mm - 2000 mm, can be cut to length Compact, for interface, electronics and power modules - 500 mm - 1000 mm - 2000 mm, can be cut to length Wide, for interface, electronics, power modules and motor starters - 500 mm - 1000 mm - 2000 mm, can be cut to length 6GK1907-0AB10-6AA0 Wide, for I/O modules and motor starters - 500 mm - 1000 mm - 2000 mm Spare fuse 12.5 A quick-response, for interface and power modules, 10 items per package unit SIMATIC Manual Collection 6GK1 901-0DB10-6AA0 6GK1 901-0DB10-6AA8 Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) SIMATIC Manual Collection Update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates 6ES7 998-8XC01-8YE2 6ES7 998-8XC01-8YE0 6ES7 194-4GD00-0AA0 6ES7 194-4GD10-0AA0 6ES7 194-4GD20-0AA0 6ES7 194-4HB00-0AA0 6ES7 194-4GB00-0AA0 6ES7 194-4GB60-0AA0 6ES7 194-4GB20-0AA0 6ES7 194-4GC70-0AA0 6ES7 194-4GC60-0AA0 6ES7 194-4GC20-0AA0 6ES7 194-4GA00-0AA0 6ES7 194-4GA60-0AA0 6ES7 194-4GA20-0AA0 Order No.

Accessories (continued) IE RJ45 Plug PRO RJ45 plug in IP65/67-rated design for on-site assembly, plastic housing, insulation/displacement connection system, for SCALANCE X-200IRT PRO and ET200pro: 1 pack = 1 unit IE SC RJ POF Plug PRO SC RJ plug for POF fibers in IP65/67-rated design for on-site assembly, plastic housing, for SCALANCE X-200IRT PRO and ET200pro 1 pack = 1 unit IE SC RJ PCF Plug PRO SC RJ plug for PCF fibers in IP65/67-rated design for on-site assembly, plastic housing, for SCALANCE X-200IRT PRO 1 pack = 1 unit Power Plug PRO 5-pole power plug for 2 x 24 V power supply in IP65/67-rated design, for on-site assembly, plastic housing, for SCALANCE X-200IRT and ET200 pro 1 pack = 1 unit IE M12 Plug PRO M12 plug for on-site assembly; (D-coded), metal housing, fast connect system, for SCALANCE X208PRO and IM 154-4 PN 1 unit 8 units IE panel feedthrough Control cabinet feedthrough for converting M12 D-coded connection system (IP65) to RJ45 connection system (IP20) 1 pack = 5 units 6GK1 901-0DM20-2AA5 6GK1900-0NB00-6AA0 6GK1900-0MB00-6AA0

5/180

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-8 PN/DP CPU interface modules

Overview
PROFINET IO Controller to operate distributed I/Os on PROFINET Component Based Automation (CBA) on PROFINET PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA) CPU with PLC functionality equivalent to S7-315-2 PN/DP, provides distributed intelligence for preprocessing Interface module to exchange preprocessed I/O data from ET 200pro with a higher-level master through PROFIBUS DP Fast, simple and end-to-end programming of a system with modular programs via STEP 7 Micro Memory Card required for operation of CPU.

Technical specifications
Order No. Product status associated programming package Supply voltages Rated value DC 24 V permissible range, lower limit (DC) permissible range, upper limit (DC) Voltages and currents external protection for supply cables (recommendation) Current consumption Inrush current, typ. It Current consumption (in no-load operation), typ. Current consumption (rated value) Power loss, typ. Memory Type of storage RAM - integrated - expandable Load memory - pluggable (MMC) - pluggable (MMC), max. Backup present without battery CPU/blocks DB Number, max. Size, max. 1 023; Number band: 1 to 1023 16 KByte Yes Yes 256 KByte No Yes 8 MByte 2 A; Typical 0.04 As; Typical 200 mA 350 mA; Typical 8.5 W; Typical MCB 24V DC / 16A with tripping characteristic Type B and C (see ET 200pro manual) Yes 20.4 V 28.8 V Size, max. FC Number, max. Size, max. OB Size, max. Nesting depth per priority class additional within an error OB CPU/processing times for bit operations, min. for word operations, min. for fixed point arithmetic, min. for floating point arithmetic, min. Times/counters and their remanence S7 counter Number of which remanent without battery - adjustable - lower limit - upper limit Remanence - adjustable - lower limit - upper limit Counting range - adjustable - lower limit - upper limit 256 Yes 0 255 Yes 0 255 Yes 0 999 0.1 s 0.2 s 2 s 3 s 8 4 16 KByte 1 024; Sequence of numbers: 0 to 2047 16 KByte STEP 7 V5.4 SP1 with HW update 6ES7 154-8AB00-0AB0 Order No. FB Number, max. 1 024; Sequence of numbers: 0 to 2047 16 KByte 6ES7 154-8AB00-0AB0

Siemens IK PI 2009

5/181

Siemens AG 2008

ET 200pro

SIMATIC ET 200 distributed I/Os

IM 154-8 PN/DP CPU interface modules

Technical specifications (continued)


Order No. IEC counter present Type S7 times Number Remanence - adjustable - lower limit - upper limit - preset Time range - lower limit - upper limit IEC timer present Type Data areas and their remanence Flag Number, max. Remanence available Number of clock memories Data blocks Number, max. Size, max. Remanence adjustable Remanence preset Local data per priority class, max. Address area I/O address area Inputs Outputs of which, distributed - Inputs - Outputs Process image Inputs, adjustable Outputs, adjustable Inputs, preset Outputs, preset Subprocess images Number of subprocess images, max. Digital channels Inputs Outputs Inputs, of which central Outputs, of which central 16 384 16 384 128 64 1 Number of variables, max. of which status variable, max. of which control variable, max. Forcing Forcing Force, variables Number of variables, max. Yes I/O 10 2 048 Byte 2 048 Byte 128 Byte 128 Byte 2 048 Byte 2 048 Byte 2 048 Byte 2 048 Byte 1 024 Byte; per block max. 510 1 023; From DB 1 to DB 1023 16 KByte Yes; From DB 1 to DB 1023 yes Granularity remanent Clock synchronization supports to MPI, Master to MPI, Slave in AS, Master in AS, Slave on Ethernet via NTP S7 message functions Number of login stations for message functions, max. Process diagnostic messages simultaneously active Alarm-S blocks, max. Test commissioning functions Status/control Status/control variable Variables Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 16 Yes 40 Yes Yes Yes No No Yes 2 048 Byte Yes; MB 0 to MB 2047 8 Deviation per day, max. Operating hours counter Number Range of values 1 2 to the power of 31 hours (when using the SFC 101) 1h Yes; must be restarted at each warm restart Yes SFB 256 Yes 0 128 No retentivity 10 ms 9 990 s Yes SFB 6ES7 154-8AB00-0AB0 Order No. Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Hardware config. Racks, max. Modules per rack, max. Number of DP masters integrated Time Clock Hardware clock (real-time clock) buffered and synchronizable Yes Yes; On MPI: master/slave; to DP: when operated as DP master: master/slave; to PROFINET: Via NTP (client only) 10 s 1 1 16; Expansion width max. 1m 1 024 1 024 64 64 6ES7 154-8AB00-0AB0

5/182

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-8 PN/DP CPU interface modules

Technical specifications (continued)


Order No. Status block Single step Number of breakpoints Diagnostic buffer present Number of entries, max. adjustable Communication functions PG/OP communication Routing Global data communication supported Size of GD packets, max. S7 basic communication supported S7 communication supported Open IE communication TCP/IP - Number of connections, max. - Data length, max. ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. UDP - Number of connections, max. - Data length, max. Number of connections overall usable for PG communication usable for OP communication usable for S7 basic communication PROFINET CBA (at set setpoint communication load) Setpoint for the CPU communication load Number of remote interconnection partners Number of functions, master/slave Total of all master/slave connections Data length of all incoming connections master/slave, max. Data length of all outgoing connections master/slave, max. Number of device-internal and PROFIBUS interconnections 50% 32 30 1 000 4 000 Byte 4 000 Byte 500 16 15 15 14 Yes 8 8 KByte Yes 8 8 KByte Yes 8 1 472 KByte Yes Yes Yes 22 Byte Yes Yes Yes 500 No 6ES7 154-8AB00-0AB0 Yes Yes 2 Order No. Remote interconnections with acyclic transmission - Sampling frequency: sampling interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. Remote interconnections with cyclic transmission - Transmission frequency: transmission interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. HMI variables via PROFINET (acyclic) - Number of log-in stations for HMI variables (PN OPC/iMap) - HMI variable updating - Number of HMI variables - Data length of all HMI variables, max. PROFIBUS proxy functionality - supported - Number of linked PROFIBUS devices - Data length per connection, max. 1st interface Type of interface Physics isolated Functionality MPI DP master DP slave Point-to-point coupling MPI Number of connections Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server Transmission speeds, max. 16 Yes Yes Yes Yes Yes No Yes 12 MBit/s Yes Yes Yes No Integral RS 485 interface RS 485 Yes 6ES7 154-8AB00-0AB0 500 ms 100 100 2 000 Byte 2 000 Byte 1 400 Byte

1 ms 200 200 2 000 Byte 2 000 Byte 250 Byte

3; 2 * PN OPC / 1 * iMap 500 ms 200 2 000 Byte

Yes 16 240 Byte

Data length of device-internal and 4 000 Byte PROFIBUS interconnections, max. Data length per connection, max. 1 400 Byte

Siemens IK PI 2009

5/183

Siemens AG 2008

ET 200pro

SIMATIC ET 200 distributed I/Os

IM 154-8 PN/DP CPU interface modules

Technical specifications (continued)


Order No. DP master Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - equidistance support - SYNC/FREEZE - Activation/deactivation of DP slaves - DPV1 Transmission speeds, max. Number of DP slaves, max. DP slave Services - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - direct data exchange (cross traffic) - DPV1 Transmission speeds, max. Transfer memory - Inputs - Outputs Address area, max. 2nd interface Type of interface Physics isolated automatic detection of transmission speed Functionality MPI DP master DP slave PROFINET IO controller PROFINET CBA Point-to-point coupling No No No Yes Yes No PROFINET Ethernet Yes Yes Yes Yes No Yes Yes No Yes Yes Yes Yes Yes 12 MBit/s 124 6ES7 154-8AB00-0AB0 Order No. PROFINET IO controller Services - PG/OP communication - Routing - S7 communication - open IE communication Transmission speed, max. Number of connectable IO-devices, max. Address area - Inputs, max. - Outputs, max. - Useful data consistency, max. CPU/programming Programming language STEP 7 Yes No No Yes No Yes Yes No 12 MBit/s 244 Byte 244 Byte 32 Yes; From V 5.3 SP1 + HW-Support Package Yes Yes Yes Yes Yes Yes

6ES7 154-8AB00-0AB0

Yes Yes Yes Yes 100 MBit/s 128

2 048 Byte 2 048 Byte 256 Byte

LAD FUP AWL SCL CFC GRAPH HiGraph Operational stocks Nesting levels User program protection/ password protection System functions (SFC) System function blocks (SFB) Isolation between backplane bus and all other circuit parts between backplane bus and electronics between supply and all other circuit parts Degree of protection IP20 rear Standards, approvals, certificates CE symbol CSA approval C-TICK cULus FM approval Dimensions Width Height Depth Weights Weight, approx.

Yes see instruction list 8 Yes see instruction list see instruction list Yes No Yes

Yes Yes No Yes Yes No 135 mm 130 mm 65 mm 555 g

5/184

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

IM 154-8 PN/DP CPU interface modules

Ordering data
IM 154-8 PN/DP CPU interface module PROFINET IO Controller to operate distributed I/Os on PROFINET, with integrated PLC functionality Accessories MMC 64 KB1)
1)

Order No. 6ES7 154-8AB00-0AB0 Accessories (continued) Industrial Ethernet FastConnect installation cables Fast Connect standard cable Fast Connect trailing cable 6ES7 953-8LF20-0AA0 6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0 Fast Connect marine cable Industrial Ethernet Fast Connect Stripping Tool IE Connecting Cable M12-180/M12-180 Preassembled IE FC TP Trailing Cable GP 2 x 2 (PROFINET Type C) with two 4-pin M12 plugs (4-pin, D-coded), degree of protection IP65/IP67, length: 0.3 m 6ES7 953-8LP20-0AA0 6ES7 194-4AN00-0AA0 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 6GK5 208-0HA00-2AA6 5.0 m 10 m 15 m IE M12 Plug PRO M12 plug-in connector suitable for on-site assembly (D-coded), metal enclosure, fast connection, for SCALANCE X208PRO and IM 154-4 PN 1 unit 8 units IE panel feedthrough Cabinet feedthrough for converting from the M12 connection system (D-coded, IP65/IP67) to the RJ45 connection system (IP20), 1 pack = 5 units 6GK1 901-1BB10-2AA0 6GK1 901-1BB10-2AB0 6GK1 901-1BB10-2AE0

Order No.

6XV1 840-2AH10 6XV1 840-3AH10 6XV1 840-4AH10 6GK1 901-1GA00

For program backup MMC 128 KB For program backup MMC 512 KB 1) For program backup MMC 2 MB 1) For program backup and/or firmware update MMC 4 MB 1) For program backup MMC 8 MB 1) For program backup Connecting module For CPU IM 154-8 PN/DP, with 4 x M12 and 2 x 7/8", to connect PROFINET and PROFIBUS DP SCALANCE X-200 Industrial Ethernet Switches With integral SNMP access, Web diagnosis, copper cable diagnosis and PROFINET diagnosis, for setting up linear, star and ring structures SCALANCE X208PRO, in degree of protection IP65, with eight 10/100 Mbit/s M12 ports, incl. eleven M12 dust caps Industrial Ethernet FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 180 cable outlet 1 unit 10 units 50 units
1)

6ES7 953-8LM20-0AA0

6XV1 870-8AE30 6XV1 870-8AE50 6XV1 870-8AH10 6XV1 870-8AH15 6XV1 870-8AH20 6XV1 870-8AH30 6XV1 870-8AH50 6XV1 870-8AN10 6XV1 870-8AN15

6GK1 901-0DB10-6AA0 6GK1 901-0DB10-6AA8 6GK1 901-0DM20-2AA5

An MMC is essential for operating the CPU

Siemens IK PI 2009

5/185

Siemens AG 2008

ET 200pro
Overview

SIMATIC ET 200 distributed I/Os

EM 141, EM 142 digital expansion modules

Expansion modules with digital inputs/outputs for connection of actuators/sensors With scalable diagnostics - Standard modules with module-specific diagnostics - High Feature modules with channel-specific diagnostics and parameterizable input delay or process interrupts (DI, up to 6 channels) Double or single assignment can be implemented for each M12 in the case of the 8DI and 8DO module by selecting CM IO 4 x M12 or CM IO 8 x M12

Technical specifications

Order No. Supply voltages Rated value DC 24 V permissible range, upper limit (DC) Reverse polarity protection

6ES7 1414BF00-0AA0

6ES7 1414BF00-0AB0

Order No. Input voltage Rated value, DC

6ES7 1414BF00-0AA0 24 V -3 to +5 V 13 to 30 V 7 mA

6ES7 1414BF00-0AB0 24 V -3 to +5 V 11 to 30 V 7 mA

Yes 28.8 V Yes; against destruction; encoder power supply outputs applied with reversed polarity

Yes 20.4 V 28.8 V Yes; against destruction; load increasing

for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - programmable - at " to "1", min.

permissible range, lower limit (DC) 20.4 V

No 1.2 ms

Current consumption from backplane bus 3.3 V DC, max. 20 mA from supply voltage 1L+, max. Power loss, typ. Address area Occupied address area Inputs FH technology Module for failsafe applications Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs all mounting positions - up to 55 C, max. Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input characteristic curve to IEC 1131, Typ 2 30 m 30 m Yes No 30 m 30 m No Yes Diagnosis: short circuit Sensor supply to M; module by module 8 8 8 8 No No No No 1 Byte 1 Byte 20 mA 2.5 W 40 mA 20 mA 2.5 W - at "1" to "0", max. Encoder supply Number of outputs Output current up to 55 C, max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Parameter Diagnostic alarm Process alarm Diagnosis: wire break Yes 1.5 mA 1A 8 4.8 ms - at "0" to "1", max. - at "1" to "0", min. 4.8 ms 1.2 ms

Yes 0.5 ms; 0.5 ms/ 3ms/ 15 ms/ 20 ms 20 ms 0.5 ms; 0.5 ms/ 3ms/ 15 ms/ 20 ms 20 ms 8 1A

Yes 1.5 mA

yes for 6 channels channel by channel channel by channel

5/186

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

EM 141, EM 142 digital expansion modules

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Diagnoses Diagnostic functions Yes Yes; channel by channel, parameterizable Yes Yes; Monitoring, I < 0.3 mA Yes; Sensor supply to M; module by module Yes Yes; per channel 500 VDC Yes 6ES7 1414BF00-0AA0 6ES7 1414BF00-0AB0 Order No. Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Permissible potential difference between different circuits Environmental requirements Degree and class of protection IP 65 IP 66 IP 67 Yes Yes; per channel 500 VDC Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Voltages and currents Load voltage 2L+ Rated value (DC) Short-circuit protection Reverse polarity protection Current consumption from load voltage 2L+ (without load), max. Power loss, typ. Address area Address space per module with packing without packing FH technology Module for failsafe applications Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. 4 30 m 30 m 3 2L+ (-47 V) 10 W 4 30 m 30 m Yes; per channel, electronic 3 2L+ (-47 V) 10 W 8 30 m 30 m Yes; per channel, electronic 0.7 2L+ (-47 V) 5W No No No 4 Bit 1 Byte 4 Bit 1 Byte 8 Bit 1 Byte 20 mA 40 mA 40 mA 2.5 W 30 mA 30 mA 2W 24 V Yes; per channel, electronic Yes; against destruction; load increasing 24 V Yes; per channel, electronic Yes; against destruction; load increasing 24 V Yes; per channel, electronic Yes; against destruction; load increasing 6ES7 142-4BD00-0AA0 6ES7 142-4BD00-0AB0 140 g 140 g 45 mm 130 mm 35 mm 45 mm 130 mm 35 mm; without terminal module Yes Yes Yes Yes Yes Yes 75 VDC / 60 VAC 75 VDC / 60 VAC No Yes No Yes 6ES7 1414BF00-0AA0 6ES7 1414BF00-0AB0

Diagnostic information readable Wire break

Yes

Short circuit

Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Isolation Isolation checked with

6ES7 142-4BF00-0AA0

from backplane bus 3.3 V DC, max. 20 mA 2W

Short-circuit protection of the output Yes; per channel, electronic

Siemens IK PI 2009

5/187

Siemens AG 2008

ET 200pro

SIMATIC ET 200 distributed I/Os

EM 141, EM 142 digital expansion modules

Technical specifications (continued)


Order No. Controlling a digital input 6ES7 142-4BD00-0AA0 Yes 6ES7 142-4BD00-0AB0 Yes 6ES7 142-4BF00-0AA0 Yes; Isolation between 1L+ and 2L+ is no longer provided, as 1M and 2M are jumpered 2L+ (-0.8 V) 0.5 A 0.5 mA No Yes 100 Hz 0.5 Hz 1 Hz

Output voltage for signal "1", min. Output current for signal "1" rated value Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) up to 55 C, max. Load impedance range lower limit upper limit Parameter Diagnosis: wire break Diagnosis: short circuit Behavior on CPU/Master STOP Status information/alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Diagnoses Diagnostic functions Diagnostic information readable Wire break Short circuit Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Channel error indicator F (red) Isolation Isolation checked with Isolation between backplane bus and all other circuit parts between the channels and backplane bus Isolation, digital outputs between the channels between the channels and the backplane bus No Yes No Yes No Yes Yes Yes 500 VDC 500 VDC 500 VDC Yes Yes Yes Yes Yes Yes Yes Yes; short-circuit of outputs to M; module by module Yes Yes Yes Yes Yes Yes Yes; short-circuit of outputs to M; module by module Yes Yes Yes Yes channel by channel channel by channel channel by channel 12 4 k 12 4 k 48 4 k 4A 4A 4A 100 Hz 0.5 Hz 1 Hz 100 Hz 0.5 Hz 1 Hz No Yes No Yes 2A 2A 0.5 mA for signal "0" residual current, max. 0.5 mA 2L+ (-0.8 V) 2L+ (-0.8 V)

5/188

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

EM 141, EM 142 digital expansion modules

Technical specifications (continued)


Order No. Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx. 140 g Order No. 6ES7 141-4BF00-0AA0 CM IO 2 x M12 connecting module Two M12 8-pin sockets; for use with: EM 8 DI, 24 V DC and 8 DO, 24 V DC/0.5 A 6ES7 141-4BF00-0AB0 CM IO 1 x M23 connecting module One socket M23; for use with: EM 8 DI, 24 V DC and 8 DO, 24 V DC/0.5 A Module identification labels 6ES7 142-4BD00-0AA0 For color coding of the CM IOs in the colors of white, red, blue and green; pack with 100 units each M12 covering cap For protection of unused M12 connections with ET 200pro 6ES7 142-4BD00-0AB0 Inscription labels 20 x 7, pale turquoise, 340 items per pack 6ES7 142-4BF00-0AA0 M12 connector, can be assembled in the field 5-pin, for connecting digital sensors and actuators, 1 unit M12 connecting cable With PUR sheath, for connecting digital sensors and actuators, pre-assembled, with connector and socket at each end 3 x 0.34 mm2, fixed lengths, 1 unit 6ES7 194-4CA50-0AA0 - 0.6 m - 1m - 1.5 m 4 x 0.34 mm2, fixed lengths, 1 unit - 0.6 m 6ES7 194-4CB00-0AA0 - 1m - 1.5 m On request On request On request On request On request On request On request 3RT1 900-1SB20 3RX9 802-0AA00 6ES7 194-4HA00-0AA0 6ES7 194-4FA00-0AA0 140 g 140 g Order No. 6ES7 194-4FB00-0AA0 45 mm 130 mm 35 mm 45 mm 130 mm 35 mm; without terminal module 45 mm 130 mm 35 mm 75 VDC / 60 VAC 6ES7 142-4BD00-0AA0 6ES7 142-4BD00-0AB0 6ES7 142-4BF00-0AA0

Ordering data
8 DI digital input module 24 V DC, with module-specific diagnostics, including bus module. Connecting module must be ordered separately 8 DI High Feature digital input module 24 V DC, with channel-specific diagnostics, including bus module Connecting module must be ordered separately 4 DO digital output module 24 V DC, 2 A, with modulespecific diagnostics, including bus module. Connecting module must be ordered separately 4 DO High Feature digital output module 24 V DC, 2 A, with channelspecific diagnostics, including bus module. Connecting module must be ordered separately 8 DO digital output module 24 V DC, 0.5 A, with modulespecific diagnostics, including bus module. Connecting module must be ordered separately Accessories CM IO 4 x M12 connecting module 4 M12 sockets for connecting digital or analog sensors or actuators to ET 200pro CM IO 4 x M12 inverse connecting module 4 sockets M12 for connection of digital actuators to ET 200pro (4 DO and 4 DO HF); 2 x M12 singly occupied, 2 x M12 doubly occupied CM IO 8 x M12 connecting module Eight M12 sockets for connecting digital sensors or actuators to ET 200pro CM IO 8 x M8 connecting module Eight sockets M8 for connection of digital sensors or actuators to ET 200pro

6ES7 194-4CA00-0AA0

6ES7 194-4EB00-0AA0

Siemens IK PI 2009

5/189

Siemens AG 2008

ET 200pro
Overview

SIMATIC ET 200 distributed I/Os

EM 144, EM 145 analog expansion modules

Expansion modules with analog inputs and outputs for connecting sensors/actuators With diagnostics functionality, limit values and substitute values

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption

6ES7 144-4FF00-0AB0

6ES7 144-4GF00-0AB0

6ES7 144-4JF00-0AB0

24 V Yes; against destruction

24 V Yes; against destruction 10 mA 1.1 W

24 V Yes; against destruction 10 mA; typically 0.7 W

from backplane bus 3.3 V DC, max. 10 mA Power loss, typ. Address area Address space per module Address space per module, max. Analog inputs Number of analog inputs cable length, shielded, max. permissible input frequency for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Constant measurement current for resistance-type transmitter, typ. Cycle time (all channels), max. technical unit for temperature measurement, adjustable Input ranges (rated values), voltages Voltage 1 to 5 V -10 V to +10 V Input resistance (-10 V to +10 V) -5 V to +5 V Yes Yes Yes 100 k Yes 267 ms 4 30 m 35 V 8 Byte 1.1 W

8 Byte 4 30 m

8 Byte 4 30 m

40 mA 1.25 mA; 1.25 / 0.5 mA depending on measuring range 267 ms 83 ms; 83 ms at 50 Hz; 69 ms at 60 Hz Yes

5/190

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

EM 144, EM 145 analog expansion modules

Technical specifications (continued)


Order No. Input ranges (rated values), currents Current -20 to +20 mA Input resistance (-20 to +20 mA) 4 to 20 mA Input resistance (4 to 20 mA) Input ranges (rated values), resistors Impedance 0 to 150 Ohm Input resistance (0 to 150 Ohm) 0 to 300 Ohm Input resistance (0 to 300 Ohm) 0 to 600 Ohm Input resistance (0 to 600 Ohm) 0 to 3000 Ohm Input resistance (0 to 3000 Ohm) Input ranges (rated values), resistance thermometers Resistance thermometer Cu 10 Ni 100 Input resistance (Ni 100) Ni 1000 Input resistance (Ni 1000) Ni 120 Input resistance (Ni 120) Ni 200 Input resistance (Ni 200) Ni 500 Input resistance (Ni 500) Pt 100 Input resistance (Pt 100) Pt 1000 Input resistance (Pt 1000) Pt 200 Input resistance (Pt 200) Pt 500 Input resistance (Pt 500) Characteristic curve linearization programmable for thermoresistor Yes Ptxxx, Nixxx Yes No Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes 10 000 k Yes Yes 50 Yes 50 6ES7 144-4FF00-0AB0 6ES7 144-4GF00-0AB0 6ES7 144-4JF00-0AB0

Siemens IK PI 2009

5/191

Siemens AG 2008

ET 200pro

SIMATIC ET 200 distributed I/Os

EM 144, EM 145 analog expansion modules

Technical specifications (continued)


Order No. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, ms 15 Bit; at +/- 10 V, at +/- 5 V; 14 bits at 0 to 10 V, at 1 to 5 V 20 / 16,667 15 Bit; at +/- -20 mA; 14 bits at 0 to 20 mA, 4 to 20 mA 20 / 16,667 50 / 60 67 ms 15 Bit; at 150, 300, 600 and 3000 ohms; otherwise 15 bits + sign 20 / 16,667 50 / 60 20.625 ms; 20.625 ms at 50 Hz; 17.25 ms at 60 Hz Yes Yes; 1x cycle time Yes; 4x cycle time Yes; 16 x cycle time Yes; 64x cycle time integrating integrating integrating 6ES7 144-4FF00-0AB0 6ES7 144-4GF00-0AB0 6ES7 144-4JF00-0AB0

Interference voltage suppression 50 / 60 for interference frequency f1 in Hz Conversion time (per channel) Smoothing of measured values parameterizable Level: none Level: weak Level: middle Yes Yes; 1x cycle time Yes; 4x cycle time Yes; 16 x cycle time Yes; 64x cycle time Yes; per module, electronic to frame 67 ms

Yes Yes; 1x cycle time Yes; 4x cycle time Yes; 16 x cycle time Yes; 64x cycle time Yes; per module, electronic to frame

Level: strong Encoder supply Short-circuit protection Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection Errors/accuracies Crosstalk between the inputs, min. Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency

Yes Yes Yes; Line resistances are also measured Yes Yes

-50 db

-50 db

-50 db

Series mode interference 50 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. Parameter Measurement type/range Interference frequency suppression Unit 70 db; Interference voltage < 5 V

50 db

50 db

70 db; Interference voltage < 5 V

70 db; Interference voltage < 5 V R4L / R3L / R2L/ TR4L / TR3L / TR2L 50/60 Hz Degrees C / Degrees F

5/192

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

EM 144, EM 145 analog expansion modules

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Limit value alarm Process alarm Diagnoses Diagnostics Wire break Short circuit Group error Overflow/underflow Diagnostics indication LED Collective error SF (red) Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels and the backplane bus Permissible potential difference between inputs and MANA (UCM) between MANA and M internally (UISO) Dimensions Dimensions Width Height Depth Weights Weight, approx. 150 g 150 g 150 g 45 mm 130 mm 35 mm 45 mm 130 mm 35 mm 45 mm 130 mm 35 mm 5 Vpp AC 500 V DC 5 Vpp AC 500 V DC 500 V DC No Yes No Yes No Yes 500 VDC 500 VDC 500 VDC Yes Yes Yes Yes; at 1 to 5 V Yes; at 1 to 5 V Yes Yes; at 4 to 20 mA Yes; at 4 to 20 mA Yes Yes Yes Yes Yes; (limit value alarm); can be set for channel 0 Yes; Parameterizable Yes; Parameterizable Yes Yes; (limit value alarm); can be set for channel 0 No Yes; Parameterizable 6ES7 144-4FF00-0AB0 6ES7 144-4GF00-0AB0 6ES7 144-4JF00-0AB0

Siemens IK PI 2009

5/193

Siemens AG 2008

ET 200pro

SIMATIC ET 200 distributed I/Os

EM 144, EM 145 analog expansion modules

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from backplane bus 3.3 V DC, max. 10 mA Address area Address space per module Address space per module, max. Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection 4 30 m Yes; per channel, electronic to chassis 50 mA 16 V 3 ms Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Short circuit Yes; per channel, not in zero range Yes; per module Yes; per module Yes Yes 3 ms 4 30 m Yes; per module, electronic to chassis 8 Byte 8 Byte 10 mA Conversion time (per channel) Settling time for resistive load for capacitive load for inductive load Parameter Diagnosis: short circuit Outputs; sensor supply to M Encoder supply to M 0.1 ms 6 ms 1 ms 0.1 ms 24 V Yes; against destruction 24 V Yes; against destruction 6ES7 1454FF00-0AB0 6ES7 1454GF00-0AB0 Order No. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 15 Bit; at -10 to +10 V; 14 bits at 1 to 5 V; 15 bits at 0 to 10 V 0.7 ms 15 Bit; at +/- 20 mA; 14 bits at 0 to 20 mA; 15 bits at 4 to 20 mA 0.7 ms 6ES7 1454FF00-0AB0 6ES7 1454GF00-0AB0

Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Cycle time (all channels) max. Output ranges, voltage 0 to 10 V 1 to 5 V -10 to +10 V Output ranges, current 0 to 20 mA -20 to +20 mA 4 to 20 mA Connection of actuators for voltage output 2-conductor connection for voltage output 4-conductor connection for current output 2-conductor connection for current output 4-conductor connection Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Destruction limits against externally applied voltages and currents Voltages at the outputs towards MANA Current, max.

Status information/ alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostic information readable Wire break Yes No Yes; per channel, not in zero range Yes Yes; Parameter- Yes; Parameterizable izable No No Yes Yes

Short circuit encoder supply Diagnostics indication LED Collective error SF (red) Isolation Isolation, analog outputs between the channels between the channels and the backplane bus

No Yes

No Yes

1 000 1 F 600 1 milliH

Dimensions Dimensions Width Height Depth Weights Weight, approx. 150 g 150 g 45 mm 130 mm 35 mm 45 mm 130 mm 35 mm

16 V; permanent 100 mA

5/194

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

EM 144, EM 145 analog expansion modules

Ordering data
4AI U analog input module High Feature, 10 V; 5 V; 0 to 10 V; 1 to 5 V, channelspecific diagnostics, including bus module. Connecting module must be ordered separately 4AI I analog input module High Feature, 20 mA; 0 to 20 mA; 4 to 20 mA, channel-specific diagnostics, including bus module. Connecting module must be ordered separately 4AI RTD analog input module High Feature; resistances: 150, 300, 600 and 3000 Ohm; resistance thermometer: Pt100, 200, 500, 1000, Ni100, 120, 200, 500 and 1000; channel-discrete diagnostics, incl. bus module. Connecting module must be ordered separately 4AO U analog output module High Feature, 10 V; 0 to 10 V; 1 to 5 V, channelspecific diagnostics, including bus module. Connecting module must be ordered separately 4AO I analog output module High Feature, 20 mA; 0 to 20 mA; 4 to 20 mA, channel-specific diagnostics, including bus module. Connecting module must be ordered separately

Order No. 6ES7 144-4FF00-0AB0 Accessories CM IO 4 x M12 connecting module 4 M12 sockets for connecting digital or analog sensors or actuators to ET 200pro 6ES7 144-4GF00-0AB0 Module identification labels for color coding of the CM IOs in the colors of white, red, blue and green; pack with 100 units each M12 covering cap 6ES7 144-4JF00-0AB0 for protection of unused M12 connections with ET 200pro

Order No.

6ES7 194-4CA00-0AA0

6ES7 194-4HA00-0AA0

3RX9 802-0AA00

6ES7 145-4FF00-0AB0

6ES7 145-4GF00-0AB0

Siemens IK PI 2009

5/195

Siemens AG 2008

ET 200pro
Overview

SIMATIC ET 200 distributed I/Os

Failsafe digital expansion modules

Ordering data
Failsafe digital input module 8/16 F-DI PROFIsafe 24 V DC, including bus module. Connecting module must be ordered separately Failsafe digital input/output module 4/8 F-DI, 4 F-DO 2 A 24 V DC, including bus module. Connecting module must be ordered separately Failsafe electronic module F-Switch PROFIsafe Three failsafe PP-switching outputs for safe switching of the rear panel busbar (2L+, F0, F1); two failsafe digital inputs, 45 mm; usable up to cat. 4 (EN 954)/SIL3 (IEC 61508) Accessories

Order No. 6ES7 148-4FA00-0AB0

6ES7 148-4FC00-0AB0

6ES7 148-4FS00-0AB0

Fail-safe digital inputs/outputs with degree of protection IP65/66/67 for application on the machine level without control cabinet Fail-safe digital inputs For fail-safe reading of sensor information (1 or 2 channels) Provide integral discrepancy evaluation for 2-out-of-2 signals Internal sensor supplies (incl. test function) available Fail-safe digital outputs Fail-safe 2-channel activation (sink/source output) by actuators Actuators can be driven by up to 2 A All modules are certified up to Cat. 4 (EN954-1) and up to SIL 3 (IEC 61508) and feature detailed diagnostics. The modules support PROFIsafe, both in PROFIBUS, and in PROFINET configurations. They can be used with IM 151-7 F-CPU, CPU31xF-2 DP, CPU31xF-2 PN/DP and CPU416F-2.

Connecting module For the fail-safe electronic module 4/8 F-DI/4 F DO, 24 V DC/2 A Connecting module For the fail-safe electronic module 8/16 F-DI, 24 V DC/2 A IM 154-2 High Feature interface module For ET 200pro, incl. termination module PROFINET interface module IM154-4 PN Including termination module M12 covering cap For protection of unused M12 connections with ET 200pro M12 connector, can be assembled in the field 5-pin, for connecting digital sensors and actuators, 1 unit M12 connecting cable With PUR sheath, for connecting digital sensors and actuators, pre-assembled, with connector and socket at each end 3 x 0.34 mm2, fixed lengths, 1 unit - 0.6 m - 1m - 1.5 m 4 x 0.34 mm2, fixed lengths, 1 unit - 0.6 m - 1m - 1.5 m

6ES7 194-4DC00-0AA0

6ES7 194-4DD00-0AA0

6ES7 154-2AA00-0AB0

6ES7 154-4AB10-0AB0

3RX9 802-0AA00

3RX8 000-0CD55

3RX1 633 3RX1 634 3RX8 000-0GF32-1AB5

3RX8 000-0GF42-1AB0 3RX8 000-0CC44-1AF0 3RX8 000-0GF42-1AB5

5/196

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

PM-E power module

Overview

Technical specifications
Order No. Power supply Input voltage Rated value, DC 24 V Current carrying capacity Current carrying capacity, max. Voltages and currents Load voltage 2L+ Short-circuit protection Reverse polarity protection Parameter missing load voltage Potential group of the power module Yes; via an exchangeable fuse in the power module Yes; against destruction 10 A; up to 55 C (on the internal busbars of the ET 200pro) Yes 6ES7 148-4CA00-0AA0

PM-E 24 V DC power module

Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostic information readable missing load voltage Diagnostics indication LED Collective error SF (red) Load voltage monitoring DC 24 V (green) Isolation Isolation checked with Environmental requirements Degree and class of protection IP 65 IP 66 IP 67 Dimensions Dimensions Width Height Depth Weights Weight, approx. 35 g 15 mm 81 mm 52 mm Yes Yes Yes 500 VDC Yes Yes Yes Yes Yes

Application
The PM-E 24 V DC power module is used for supplementary supply or grouping of the 24 V load voltage for electronic modules within an ET 200pro station. The following module is available: PM-E 24 VDC PM-E connection module (must be ordered separately): CM PM-E directly (with up to 2 M20 screwed cable glands) CM PM-E ECOFAST Cu (with one ECOFAST Cu connection) CM PM-E 7/8" (with one 7/8" socket) CM PM-E push-pull 2 x 24 VDC

Siemens IK PI 2009

5/197

Siemens AG 2008

ET 200pro
Ordering data

SIMATIC ET 200 distributed I/Os

PM-E power module


Order No. 6ES7148-4CA00-0AA0 Accessories for CM PM-E direct Power line 5-core, 5 x 1.5 trailing type, sold by the meter, minimum order quantity 20 m, maximum order quantity 1,000 m 6ES7 194-4BA00-0AA0 Accessories for CM PM-E 7/8 7/8" connecting cable to power supply 6ES7 194-4BC00-0AA0 5-core, 5 x 1.5 mm2, trailing type, pre-assembled with two 7/8" connectors, 5-pin 1.5 m long 2.0 m long 6ES7 194-4BD00-0AA0 3.0 m long 5.0 m long 10 m long 6ES7 194-4BE00-0AA0 15 m long 7/8" cable connector 6ES7 194-4HB00-0AA0 with axial cable outlet with male insert, 5 per pack with female insert, 5 per pack 6XV1 830-0GH10 6GK1 905-0FA00 6GK1 905-0FB00 6XV1 822-5BH15 6XV1 822-5BH20 6XV1 822-5BH30 6XV1 822-5BH50 6XV1 822-5BN10 6XV1 822-5BN15 mm2, 6XV1 830-8AH10 Order No.

PM-E 24 V DC power module for backfeed and group formation of the 24 V DC load supply for electronic modules within an ET 200pro station. Accessories CM PM-E ECOFAST connecting module for backfeed of 24 V load voltage, 1 ECOFAST Cu connection CM PM-E direct connecting module for backfeed of 24 V load voltage, up to 2 M20 screwed cable glands CM PM-E 7/8" connecting module for backfeed of 24 V load voltage, 1 x 7/8" CM PM-E PP connection module for supplying 24-V load voltage, 2 x push-pull, with spare fuse Spare fuse 12.5 A quick-response, for interface and power modules, 10 items per package unit PROFIBUS FC Food bus cable with PE sheath for use in the food and beverages industry, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum cable length 1000 m PROFIBUS FC Robust bus cable with PUR sheath for use in environments in which aggressive chemicals and mechanical loads are encountered, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum cable length 1000 m PROFIBUS FC trailing cable Minimum bending radius approx. 60 mm, 2-core, shielded, sold by the meter, minimum order quantity 20 m, max. cable length 1000 m

6XV1 830-0JH10

6XV1 830-3EH10

5/198

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro

PM-O power module

Overview

Technical specifications
Order No. Power supply Current carrying capacity Current carrying capacity, max. Supply voltages Supply voltage from power module Rated value (DC) Voltages and currents Load voltage 2L+ Short-circuit protection Reverse polarity protection Parameter Remark Diagnosis short circuit implemented after M for 1L+ Yes Yes; against destruction 24 V Output current 2 A for 1L+ and 6 A for 2L+ 6ES7 148-4CA60-0AA0

PM-O 2 x 24 VDC power module with CM PM-O PP

PM-O 2x 24 VDC power module

Status information/ alarms/diagnostics Diagnoses Diagnostic functions Diagnostic information readable Fuse blown Yes Yes No; Indirect diagnosis (short circuit after M for 1L+), since electronic fuse No No Yes No

Application
The PM-O DC 2 x 24 V power module serves to extract the 24 V load voltage 2L+ and electronic/encoder supply 1L+ within an ET 200pro station. In connection with an F-switch (6ES7 148-4FS00-0AB0) the PM-O can be used for safe deactivation of loads. The following module is available: PM-O 2 x 24 VDC PM-E connection module (must be ordered separately): CM PM-O PP

missing load voltage Diagnostics indication LED Rated load voltage PWR (green) Collective error SF (red) Load voltage monitoring DC 24 V (green) Isolation primary/secondary Environmental requirements Degree and class of protection IP 65 IP 66 IP 67 Dimensions Dimensions Width Height Depth Weights Weight, approx.

No

Yes Yes Yes

45 mm 130 mm 35 mm 150 g

Ordering data
PM-O 2 x 24 VDC power module For drawing the 24 V load voltage 2L+ and electronic/ encoder supply voltage 1L+ within an ET 200pro station. Accessories CM PM-O PP connection module For drawing the 24 V load voltage and electronic/encoder supply voltage, 2 x push-pull connector

Order No. 6ES7148-4CA60-0AA0

6ES7 194-4BH00-0AA0

Siemens IK PI 2009

5/199

Siemens AG 2008

ET 200pro
Overview

SIMATIC ET 200 distributed I/Os

ET 200pro pneumatic interface

Application
The pneumatic interface is designed for an original FESTO valve terminal. The ET 200pro can then also be used for applications requiring flexible pneumatics. A wide variety of valve functions from the standard FESTO spectrum and a choice of flow rates facilitate an extensive range of applications. CPV 10 or CPV 14 FESTO valve terminals can be used and are available from FESTO.

Interface for holding an original FESTO CPV 10 or CPV 14 compact performance valve terminal For using the ET 200pro in applications with flexible pneumatics Highly flexible pneumatics with a variety of valve functions and choice of flow rates

Technical specifications
Order No. Voltages and currents Load voltage 2L+ Rated value (DC) Short-circuit protection Reverse polarity protection Current consumption 24 V Yes Yes 20 mA 24 V Yes Yes 20 mA 25 mA 3.7 W Behavior on CPU/Master STOP Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostic functions Diagnostic information readable Diagnostics indication LED 2 Byte 16 12 mA 25 Hz 2 Byte 16 16 mA 20 Hz Collective error SF (red) Status indicator digital output (green) Isolation Isolation checked with tested with Load voltage L+ against backplane bus Isolation 250 mA; only up to 50 C, limited by valves 500 2 500 330 mA; only up to 50 C, limited by valves 500 2 500 between backplane bus and all other circuit parts between the channels and backplane bus Isolation, digital outputs between the channels and the backplane bus Permissible potential difference between different circuits 75 VDC / 60 VAC 75 VDC / 60 VAC Yes Yes Yes Yes Yes Yes 500 V DC 500 V DC 500 VDC 500 VDC Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 1484EA00-0AA0 6ES7 1484EB00-0AA0 Order No. Parameter Remark Diagnosis load voltage 2L+ no Diagnosis load voltage 2L+ 6ES7 1484EA00-0AA0 6ES7 1484EB00-0AA0

from load voltage 2L+ (without load), max. Power loss, typ. Address area Address space per module without packing Digital outputs Number of digital outputs Output current for signal "1" rated value Switching frequency with inductive load, max. Aggregate current of the outputs (per group) up to 55 C, max.

from backplane bus 3.3 V DC, max. 25 mA 2.6 W

Load impedance range lower limit upper limit

Ordering data
EM 148-P pneumatic interface DO 16 x P/CPV 10 for direct accomodation of FESTO valve terminal CPV 10 16 DO x P DO 16 x P/CPV 14 for direct accomodation of FESTO valve terminal CPV 14 16 DO x P FESTO CPV10 valve terminal FESTO CPV 14 valve terminal

Order No.

6ES7 148-4EA00-0AA0

6ES7 148-4EB00-0AA0

available from FESTO available from FESTO FESTO AG & Co Ruiterstr. 82 D-73732 Esslingen More addresses in the Internet at: http://www.festo.de

5/200

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro RFID systems


SIMATIC RF180C

Overview

Application
The PROFINET communication module SIMATIC RF180C has been specially designed for a wide range of applications in industrial automation and logistics. Due to the high degree of protection IP67, SIMATIC RF180C can be installed in the process outside the control cabinet. Main applications for SIMATIC RF180C: Machine manufacturing, automation systems, conveyor systems Ancilliary assembly lines in the automotive industry / suppliers Small assembly lines

Design
PROFINET IO Master module e.g. S7-400

The SIMATIC RF180C is a communications module for direct connection of Siemens RFID systems to PROFINET IO. The readers (SLGs) of the RFID systems MOBY I, E, D, U and SIMATIC RF300 can be operated on the SIMATIC RF180C. Due to the high degree of protection and its ruggedness, SIMATIC RF180C is ideally suited to use at machine level. The uniform plug-in connection system ensures rapid commissioning.

SIMATIC RF180C

PROFINET Industrial Ethernet 24 V for RF180C and reader to other PROFINET bus nodes

Benefits
Two parallel MOBY channels ensure real-time operation of the dynamic read points Reader connection with an 8-pole M12 connector for rapid assembly of all components Easy changeover from PROFIBUS applications to PROFINET with SIMATIC RF180C thanks to software compatibility The integrated switch allows several PROFINET modules to be installed in star or bus topology. Each application can then be built up quickly and inexpensively Powerful hardware ensures rapid data communication with the reader (SLG). So that the data are available to the application more quickly Simple firmware downloading in the case of function expansions and error rectification ensures high availability of the RFID system Adjustable and parameterizable RFID-specific diagnostics facilitate commissioning and troubleshooting A broad selection of pre-assembled connecting cables can be ordered for connecting PROFINET and readers to SIMATIC RF180C. This saves time and money during installation and increases the quality The hardware configuration with a base unit and connection block ensures that SIMATIC RF180C is prepared for other connection techniques, such as fiber-optic cables

2. Reader

1. Reader

Tags / MDS

Siemens IK PI 2009

5/201

G_FS10_XX_00228

Siemens AG 2008

ET 200pro RFID systems


SIMATIC RF180C

SIMATIC ET 200 distributed I/Os

Function
The SIMATIC RF180C comprises a basic module and a connection block that must be ordered separately. The connection block is available in the version M12, 7/8''. PROFINET is connected through an M12 plug, whereas the supply voltage is connected through a 7/8'' plug. There are 2 connections for PROFINET as well as for the power supply. This ensures that SIMATIC RF180C can be connected to additional bus stations without the need for external distribution devices. The removable connection block allows a base module to be replaced without interrupting the supply voltage to other bus stations. SIMATIC RF180C is integrated in SIMATIC STEP 7 via the GSDML file. SIMATIC RF180C can then be configured via the SW tool HW_Config of SIMATIC Manager or another PROFINET tool. A pre-assembled reader cable is used to connect one or two readers to the communication module. The standard cable length is 2 m. If other reader cable lengths are required, an extension cable from 2 to 50 m in length can be used. The cable can also be assembled by the customer as required.

Technical specifications
Type Supply voltage Nominal value Permissible range Current consumption Without reader, typ. With two readers, max. Serial reader interface (gross transmission rate) MOBY I/E MOBY U/D, RF300 Connectors Cable length to reader Standard length Optional preassembled cables Self-assembled cables Supply voltage to reader Max. current per reader 2 readers connected 1 reader connected Ambient temperature Operation Storage Shock load during operation acc. to IEC 61131-2 Vibratory load during operation acc. to IEC 61131-2 Enclosure Material Color Degree of protection Dimensions (W x H x D) in mm SIMATIC RF180C without connection block SIMATIC RF180C with connection block Weight Base module only Connection block only 210 g 230 g 60 x 210 x 30 60 x 210 x 54 Thermoplastic (fiberglass reinforced) IP Basic 714 IP67 -0 ... 60 C -40 ... +70 C, 20 K/h 30 g 0.75 mm (10 58 Hz) 10 g (58 150 Hz) 0.5 A 1.0 A 2m 5 m, 10 m, 20 m, 50 m Reader/SLG-dependent. Up to 1000 m 24 V 19200 bit/s 19200, 57600, 115200 bit/s 2 x connector plug M12, 8-pin 100 mA 1000 mA 24 V DC 20 30 V DC SIMATIC RF180C

The data in the transponder can be accessed in the following manner: Direct addressing via absolute addresses Error messages and operating states (tag in field, transfer, etc.) are also displayed on LEDs and support commissioning and service. SIMATIC RF180C has two reader interfaces from which the readers are also supplied with voltage. There is a solid-state fuse in SIMATIC RF180C for the reader power supply. The maximum current permitted for the readers per SIMATIC RF180C is 1 A. It is not important here whether the current is drawn by 1 or 2 readers. The application accesses the tag via FB45. FB45 accesses the tag via absolute addresses. For large volumes of data and complex tag operations, the FB45 can process chained commands. Data is exchanged between SIMATIC RF180C and the application by means of acyclic data records. This ensures that a large quantity of data can be transferred from/to SIMATIC RF180C without loading the bus cycle. This is advantageous when large volumes of data are being transferred. SIMATIC RF180C can also process chained tag commands in this mode extremely quickly.

5/202

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro RFID systems


SIMATIC RF180C

Ordering data
SIMATIC RF180C communication module For PROFINET, for connecting 2 readers; without a connection block Accessories for MOBY Connection block for SIMATIC RF180C for connecting 2 readers over an M12 cable connector M12 connecting cable, prefabricated, between SIMATIC RF180C and SIMATIC RF300 reader; 2m, plug angled SLG cable for MOBY I/E/U; 2m SLG cable for MOBY I/E/U; 5m SLG cable for MOBY D; 2m SLG cable for RF300 Extension cable for MOBY I/E/U/D/RF300; 2m SLG cable for RF300 Extension cable for MOBY I/E/U/D/RF300; 5m SLG cable for RF300 Extension cable for MOBY I/E/U/D/RF300; 10 m SLG cable for RF300 Extension cable for MOBY I/E/U/D/RF300; 20 m SLG cable for RF300 Extension cable for MOBY I/E/U/D/RF300; 50 m M12 sealing caps for unused reader connections (10 units)

Order No. 6GT2 002-0JD00

Order No. Accessories for connection to the network PROFINET cable with M12 plugs, pre-assembled; for trailing Cable for supply voltage pre-assembled with 7/8'' plugs 6XV1 870-8Axxx1)

6XV1 822-5Bxxx1) 6XV1840-2AH10

6GT2 002-1JD00

PROFINET standard cable 2x2, Type A, not pre-assembled; minimum order quantity 20 m PROFINET M12 plug connector; rugged metal housing; fast connect system; D-coded (pack of 1) 7/8'' cable connector for voltage (pack of 5)

6GK1901-0DB10-6AA0

6GT2 891-0JH20

6GT2 091-0FH20 6GT2 091-0FH50 6GT2 691-0FH20 6GT2 891-0FH20

With pin insert With socket insert IE M12 cabinet bushing for conversion from M12 (D-coded) to RJ45; (pack of 5) IE FC RJ45 PLUG 180 RJ45 plug connector with rugged metal housing and FC connection system; straight cable outlet (pack of 1)

6GK1 905-0FA00 6GK1 905-0FB00 6GK1901-0DM20-2AA5

6GK1901-1BB10-2AA0

6GT2 891-0FH50

6GT2 891-0FN10

6GT2 891-0FN20

6GT2 891-0FN50

3RX9 802-0AA00

1)

This cable is available in different lengths (see Section 2 "Passive network components")

Siemens IK PI 2009

5/203

Siemens AG 2008

ET 200pro RFID systems


SIMATIC RF180C

SIMATIC ET 200 distributed I/Os

Dimensions
60
SIMATIC RF180C

28

FS10_90115

SIMATIC RF180C

210

24

CAD data Dimension drawing available as CAD graphic (DXF format). Additional information can be found in the Internet under: http://www.automation.siemens.com/ bilddb/index.asp?objKey=G_FS10_XX_90115

5/204

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro RFID systems


SIMATIC RF170C

Overview

Application
The ET 200pro distributed I/O system with the SIMATIC RF170C communication module has been specially designed for a wide range of applications in industrial automation and logistics. Thanks to the high degree of protection of IP67, the SIMATIC RF170C can be installed without a control cabinet. Used primarily for the SIMATIC RF170C: Mechanical engineering, automation systems, conveyor systems Ancillary assembly lines in the automobile industry/suppliers Small assembly lines

Design
PROFIBUS or PROFINET/Industrial Ethernet Master module e.g. S7-400

The SIMATIC RF170C is a communication module for connecting the Siemens RFID systems to the ET 200pro distributed I/O system. The readers (SLGs) of all RFID systems can be operated on the SIMATIC RF170C. Thanks to its high degree of protection and ruggedness, ET 200pro is particularly suitable for machine-level use. The modular structure with PROFIBUS and PROFINET connection systems allows them to be used in all applications. The systemwide, plug-in connection technique ensures rapid start-up.

5
PROFINET/ Industrial Ethernet PROFIBUS to other bus nodes 24 V for ET 200pro, RF170C and reader
G_FS10_XX_00177

ET 200pro interface module SIMATIC RF170C

Benefits
Two parallel MOBY channels ensure real-time mode at dynamic read points. By selecting the relevant header module, the RFID systems can be connected via PROFIBUS or PROFINET. The modular design with interface modules for PROFIBUS and PROFINET supports universal implementation. Reader connection using an 8-pin M12 connector for fast installation of all components. Easy changeover from ET 200X with ASM 473 to ET 200pro with SIMATIC RF170C thanks to 100 % software compatibility. High-performance hardware ensures fast data exchange with the SLG (reader). Consequently the data are available for the application even faster. Easy downloading of firmware via SIMATIC Manager for function expansions and error rectification ensure high-availability of the RFID system. The parameterizable RFID-specific diagnostics support startup and troubleshooting A wide selection of pre-assembled connecting cables can be ordered for ET 200pro and SIMATIC RF170C. This saves time and money during installation and assures better quality.

2nd Reader

1st Reader

Tags / MDS

Siemens IK PI 2009

5/205

Siemens AG 2008

ET 200pro RFID systems


SIMATIC RF170C

SIMATIC ET 200 distributed I/Os

Function
The SIMATIC RF170C comprises an electronics module and a connection block that must be ordered separately. The interface module is available in the PROFIBUS or PROFINET variants. For the PROFIBUS connection, you can choose from the connection systems of ECOFAST, M12, 7/8", or screwed cable gland. For the PROFINET interface module, M12, 7/8" connection is available. Integration of SIMATIC RF170C into SIMATIC STEP 7 is achieved by means of an object manager (OM). The GSD file of the ET 200pro system is available for integration into non-Siemens systems. Then the SIMATIC RF170C can be configured by means of the software tool HW_Config of the SIMATIC Manager or another PROFIBUS/PROFINET tool. One or two readers are connected to the interface module using an off-the-shelf reader cable. The standard length of the cable is 2 m. If other cable lengths to the reader are required, an extension cable measuring between 2 m and 50 m can be used. The cable can also be assembled by the customer as required. In principle, access to the data in the transponder can take place as follows. Direct addressing via absolute addresses Conveniently via the MOBY file handler (MOBY I/U only) using file names Error messages and operating states (tag in the field, transmission, etc.) are indicated additionally by means of LEDs and simplify commissioning and service. The SIMATIC RF170C has two reader interfaces from which the readers are also supplied with power. In the SIMATIC RF170C, the power supply for the readers has an electronic fuse. The maximum permissible current per SIMATIC RF170C for the readers is 0.8 A. It is of no importance here whether the current is drawn by one or two readers. The data in the MDS can be directly accessed by means of absolute addresses (FB/FC45, FC55) or more conveniently using the MOBY file handler (FB, FC 56) by means of the file names. When the ET 200pro is operated with a PROFINET interface, use of the FB (FB45, FB56) is mandatory. Communication between the SIMATIC RF170C and the controller is acyclic. Consequently, a very large amount of data can be transferred to/from the SIMATIC RF170C without overloading the bus cycle. This has advantages when transferring large volumes of data. In addition, the SIMATIC RF170C can process concatenated tag commands very quickly in this mode.

Technical specifications
Communication module Ambient temperature During operation During storage Relative humidity Atmospheric pressure Resistance to shock Vibration Power supply Nominal value Permissible range Current consumption Without reader With 2 readers Enclosure Degree of protection Enclosure material Housing color Dimensions (W x H x D) in mm SIMATIC RF170C without connection block SIMATIC RF170C with connection block Weight Without connection block With connection block Serial reader interface (gross transmission rate) Connectors Cable length to reader Standard length Optional preassembled cables Self-assembled cables Supply voltage to reader Max. current; 2 readers connected Max. current; 1 readers connected 2m 5 m, 10 m, 20 m, 50 m According to write/read device. Up to 1000 m 24 V 0.4 A per reader 0.8 A per reader Approx. 270 g Approx. 770 g MOBY I/E: 19200 baud MOBY U/D, RF300: 19200, 57600, 115200 baud 2 x connector plug M12, 8-pin 90 x 130 x 35 90 x 130 x 60 IP67 Thermoplastic (fiberglass reinforced) IP Basic 714 typ. 130 mA Max. 1000 mA 24 V DC 20.4 28.8 V DC -25 +55 C -40 +70 C 20 K/h 5 to max. 100 % from 795 to 1080 hPa as for ET 200pro as for ET 200pro SIMATIC RF170C

5/206

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200pro RFID systems


SIMATIC RF170C

Ordering data
SIMATIC RF170C communication module For connecting to the distributed I/O system ET 200pro Accessories Connection block for SIMATIC RF170C, for connection of 2 readers using M12 connectors M12 connecting cable, prefabricated, between SIMATIC RF170C and SIMATIC RF300 reader; 2m, plug angled SLG cable for MOBY I/E/U; 2m SLG cable for MOBY I/E/U; 5m SLG cable for MOBY D; 2m SLG cable RF300 extension cable MOBY I/E/U/D and SIMATIC RF300; 2m SLG cable RF300 extension cable MOBY I/E/U/D and SIMATIC RF300; 5m SLG cable RF300 extension cable MOBY I/E/U/D and SIMATIC RF300; 10 m SLG cable RF300 extension cable MOBY I/E/U/D and SIMATIC RF300; 20 m SLG cable RF300 extension cable MOBY I/E/U/D and SIMATIC RF300; 50 m M12 sealing caps, for unused reader connections (10 units)

Order No. 6GT2 002-0HD00

Dimensions

89,9

6GT2 002-1HD00

6GT2 891-0JH20
121,4
SIMATIC RF170C

6GT2 091-0FH50 6GT2 691-0FH20 6GT2 891-0FH20

FS10_90114

6GT2 091-0FH20

131,2

5
SIMATIC RF170C communications module

6GT2 891-0FH50

6GT2 891-0FN10
90

6GT2 891-0FN20

READER 1

6GT2 891-0FN50

3RX9 802-0AA0

READER 2

Connector block for SIMATIC RF170C

CAD data
Dimension drawing available as CAD graphic (DXF format).

Additional information can be found in the Internet under: http://www.automation.siemens.com/ bilddb/index.asp?objKey=G_FS10_XX_90114

Additional information can be found in the Internet under: http://www.automation.siemens.com/ bilddb/index.asp?objKey=G_FS10_XX_90116

FS10_90116

120 130

Siemens IK PI 2009

5/207

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro Motor Starters

SIMATIC ET 200 distributed I/Os

Overview

Benefits
ET 200pro motor starters provide the following advantages: High flexibility thanks to a modular and compact design Little variance among all motor starter versions (2 units up to 5.5 kW) Extensive parameterization using STEP 7 HW-Config Increase of plant availability through fast replacement of units (easy mounting and plug-in technology) Extensive diagnostics and information for preventive maintenance Parameterizable inputs for local control functions (High Feature) Cabinet-free construction by means of high degree of protection IP65.

Application
Motor starters Only two versions up to 5.5 kW All settings can be parameterized by bus Comprehensive diagnostic signals Overload can be acknowledged by remote reset Current unbalance monitoring Stall protection Emergency start function in the event of overload Current value transmission by bus Current limit monitoring Direct-on-line or reversing starters Power bus can be plugged in using the new HAN Q4/2 plug-in connectors Conductor cross-sections up to 6 x 4 mm 25 A per segment (power looped through using jumper plug) In the Standard and High Feature versions (with 4 DI onBoard) Electromechanical switching and electronic switching Electronic starter for direct activation or with integrated smooth-starter function Supplied with 400 V AC brake contact as an option Isolator module The isolator module with switch disconnector function is used for safe disconnection of the 400 V operational voltage during repair work in the plant and provides an integrated group fusing function (i. e. additional group short-circuit protection for all subsequently supplied motor starters). Depending on the power distribution concept, all stations can be equipped with an isolator module as an option. Safety applications Safety local isolator module With the Safety local modules Safety local isolator module and 400 V disconnecting module it is possible to achieve safety category 4/SIL 3 with an appropriate connection. Safety Solution PROFIsafe With the Safety PROFIsafe modules F-Switch and 400 V disconnecting module it is also possible to achieve safety category 4/SIL 3 with an appropriate connection. With the ET 200pro motor starters, any AC loads can be protected and switched. They are an integral part of ET 200pro and have the high degree of protection IP65. This makes them ideal for operation in modular, distributed peripherals without control cabinets or control enclosures. The ET 200pro motor starters are available both with mechanical as well as electronic contacts. The ET 200pro electromechanical starters are offered as direct (DSe/DSe) and reversing starters (RSe/RSe) in the High Feature version with the following equipment: 4 digital inputs Device versions with or without control for externally fed brakes with 400 V AC With expanded parameterization capabilities. The ET 200pro electronic starters are offered as direct (DSe/DSe) and reversing starters (RSe/RSe) in the High Feature version with the following equipment: 4 digital inputs With soft-start and smooth ramp-down function With the deactivated smooth start function as an electronic starter for applications with a high level of switching frequency Device versions with or without control for externally fed brakes with 400 V AC With expanded parameterization capabilities. As the result of the protection concept with solid-state overload evaluation and the use of SIRIUS controls size S00, additional advantages are realized on the standard and High-Feature motor starters - advantages which soon make themselves positively felt particularly in manufacturing processes with high plant stoppage costs: Configuration is made easier by the fine modular structure. When using the ET 200pro motor starters, the list of parts per load feeder is reduced to two main units: the bus module and the motor starter. This makes the ET 200pro ideal for modular machine concepts or solutions for conveying systems and in machine-tool building. Expansions are easily possible through the subsequent adding of modules. The innovative plug-in technology also does away with the wiring needed up to now. Through the hot swapping function (disconnection and connection during operation) a motor starter can be replaced within seconds if necessary, without having to shut down the ET 200pro station and with it the process in the plant. The motor starters are therefore recommendable in particular for applications with special demands on availability. Storage costs are optimized in addition by the low level of variance (2 units up to 5.5 kW).

5/208

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro Motor Starters

SIMATIC ET 200 distributed I/Os

Application (continued)
The ordering option for motor starters with a 400 V AC brake output provides the possibility of controlling motors with 400 V AC brakes. With four locally acting inputs available on the High Feature motor starter it is possible to realize autonomous special functions which work independently of the bus and the higher-level control system, e. g. as a quick stop on gate valve controls or limit position disconnectors. In parallel with this, the states of these inputs are signaled to the control system. When using the optional isolator module with switch disconnector and group fusing function for the ET 200pro, the 400 V supply of the motor starters can be switched on and off directly in the field, i.e. locally.

Selection and ordering data


Version Order No.

Standard motor starters, mechanical


Motor protection: thermal model DSe1) direct-on-line starters Without brake output With brake output 400 V AC RSe reversing starters1) Without brake output With brake output 400 V AC
DSe standard

3RK1 304-57S40-4AA0 3RK1 304-57S40-4AA3 3RK1 304-57S40-5AA0 3RK1 304-57S40-5AA3

High-Feature motor starters, mechanical


Motor protection: thermal model DSe direct-on-line starters1) Without brake output and with 4 inputs With brake output 400 V AC and 4 inputs RSe reversing starters1) Without brake output and with 4 inputs With brake output 400 V AC and 4 inputs
RSe High-Feature

3RK1 304-57S40-2AA0 3RK1 304-57S40-2AA3 3RK1 304-57S40-3AA0 3RK1 304-57S40-3AA3

Setting range of rated operational current 0.15 ... 2.0 A 1.5 ... 12.0 A K L

High-Feature motor

starters3),

solid-state

Full motor protection, comprising thermal motor protection and thermistor motor protection sDSSte/sDSte direct-on-line starters1)3) Without brake output and with 4 inputs With brake output 400 V AC and 4 inputs sRSSte/sRSte reversing starters1)3) Without brake output and with 4 inputs With brake output 400 V AC and 4 inputs
sRSSte High Feature

3RK1 304-57S70-2AA0 3RK1 304-57S70-2AA3 3RK1 304-57S70-3AA0 3RK1 304-57S70-3AA3

Setting range of rated operational current 0.15 ... 2.0 A 1.5 ... 12.0 A
1) 3)

K L
The solid-state motor starters can be used not only as solid-state motors starters with a high level of switching frequency but also as fully fledged soft starters for soft starting and smooth ramp-down. The changeover from motor starter to soft starter takes place through reparameterization in HW Config. Depending on the settings, this results in the following current ranges: - Parameterization as solid-state starter: 0.15 ... 2 A and 1.5 ... 9 A (4 kW) - Parameterization as soft starter: 0.15 ... 2 A and 1.5 ... 12 A (5.5 kW).

2)

Only functions when used together with the backplane bus module and the wide module rack. The backplane bus module and the wide module rack must be ordered separately (see "Accessories for ET 200pro motor starters"). Delivery time class A for setting range of rated operational current 0.15 ... 2.0 A

Siemens IK PI 2009

5/209

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro motor starters ET 200pro isolator modules

SIMATIC ET 200 distributed I/Os

Overview
The isolator module with integrated group fusing function (i.e. additional group short-circuit protection for all subsequently supplied motor starters) and switch disconnector function is used for safe disconnection of the 400 V operational voltage in the plant. Depending on the power distribution concept, all stations can be equipped with an isolator module as an option. The isolator module is available in addition in a safety version. See Safety local Isolator module.

Benefits
The following properties apply to the isolator module: Increase of plant availability through fast replacement of units (easy mounting and plug-in technology) Cabinet-free construction by means of high degree of protection IP65.

Selection and ordering data


Version ET 200pro isolator modules, mechanical Isolator module1) Rated operational current 25 A 3RK1 304-0HS00-6AA0 Order No.

5
3RK1 304-0HS00-6AA0

Safety local isolator module2)3) Rated operational current 16 A

3RK1 304-0HS00-7AA0

3RK1 304-0HS00-7AA0
1)

2) 3)

Only functions when used together with the corresponding backplane bus module 110 mm and the wide module rack. The backplane bus module and the wide module rack must be ordered separately (see "Accessories for ET 200pro motor starters"). The Safety local isolator module only functions when used together with the 400 V disconnecting module. Only in combination with the special backplane bus module for the Safety local isolator module (see "Accessories for ET 200pro motor starters").

5/210

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro FC frequency converters

SIMATIC ET 200 distributed I/Os

Overview

Benefits
The frequency converter is completely embedded in the ET 200pro system and provides all the system advantages such as the cabinet-free design, the simple mounting on the module rack, the reduction of the wiring outlay through self-assembling communication and supply rails in the backplane bus, extensive diagnostic mechanisms and high availability through exchangeability without influencing other modules in the ET 200pro station. The load voltage is relayed to the following frequency converters or motor starters with minimum installation costs via preassembled jumper plugs. The maximum current carrying capacity of the jumper plug is 25 A Simple combination and expansion of the converter functionality through I/O modules or isolator module inside the distributed station Input for PTC/KTY sensor for comprehensive motor protection The integrated DC 180-V brake controller makes the rectifiers in the motor terminal box redundant Slot for optional memory card (MMC) for saving the parameterization for fast module exchange with automatic reparameterization Types of control available: Frequency control, sensor-less vector control or torque control Parameterizing takes place via STARTER, the graphic parameterizing tool for Siemens operating systems, either via the connected field bus or a point-to-point connection Note: Access of the STARTER to the frequency converter via the bus is not possible if there is a CPU between the PC and the frequency converter. This also applies for the CPU IM 154-8. Active and dynamic braking of the motor is possible without additional outlay. The resulting brake power is fed back into the supply network making brake choppers and pulse resistors unnecessary The failsafe version of the frequency converter provides autonomous, certified safety functions which contribute to protecting man and machine against dangerous movements in machines. The integration of the safety technology in the operating mechanism also simplifies the machine architecture and allows complete diagnostics. Actuation of the failsafe functions of the local frequency converter with the F-RSM Safety local isolator module or via field bus with the F-Switch PROFIsafe module.

Standard ET 200pro FC frequency converters and with integrated safety functions

Two versions with and without integrated safety functions Power 1.1 kW (1.5 kW at max. 45 C ambient temperature) Vector control, frequency controller or torque control without sensors Integrated brake controller DC 180 V Power recovery Power looped through using jumper plug with 25 A per segment User-friendly parameterization via bus Comprehensive diagnostics

Siemens IK PI 2009

5/211

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro FC frequency converters

SIMATIC ET 200 distributed I/Os

Application
The frequency converter steplessly controls the speed of asynchronous motors The modular, service-friendly concept of the frequency converter makes it particularly suitable for manufacturing processes with high plant stoppage costs The grouping of several frequency converters into a distributed station enables optimum solutions for spatially or functionally adjacent operating mechanisms. The frequency converter governs both frequency control for simple applications and vector control for more challenging operating mechanism tasks. It also sees to the optimum actuation of any motor brake that is present. The converter also supports torque control, e.g. for applications with mechanically coupled operating mechanisms The advantages of the line-commutated power recovery are shown above all in continuous regenerative mode. Examples of these are unwinders, the lowering of loads or the dynamic braking of large centrifugal masses. The integrated safety functions greatly reduce the outlay for operating mechanism solutions in system sections where there is potential danger. Additional savings result through sensor-less monitoring of the speed of standard asynchronous motors

Technical specifications
ET 200pro frequency converters with integrated safety functions Selection features Integrated safety functions based on Category 3 of EN 954-1 and SIL 2 of IEC 61508 Safe torque off (STO) Safely limited speed (SLS)1) Safe stop 1 (SS1)1) Control of the integrated safety functions via F-RSM Safety local isolator module or via F-Switch PROFIsafe 3 AC 380 V to 480 V +10 %/-10 % 1.1 kW

Electrical specifications Mains voltage Power (at 0 C to 55 C ambient temperature) Rated input current (at 0 C to 55 C ambient temperature) Rated output current (at 0 C to 55 C ambient temperature) Power (at 0 C to 45 C ambient temperature) Rated input current (at 0 C to 45 C ambient temperature) Rated output current (at 0 C to 45 C ambient temperature) Mains frequency Overload capacity

2.0 A

3.5 A

Design

1.5 kW

2.5 A

3.9 A

47 Hz up to 63 Hz Overload current 1.5 x rated output current (i.e. 150 % overload) during 60 s cycle time 300 s Overload current 2 x rated output current (i.e. 200 % overload) during 3 s, cycle time 300 s 0 Hz up to 650 Hz 4 kHz (standard), 2 kHz to 16 kHz (in 2-kHz steps) 10 kA

Installation of an ET 200pro station with 2 ET 200pro FC frequency converters with integrated safety functions

The ET 200pro FC comprises the following components: Standard ET 200pro FC frequency converters or with integrated safety functions Special backplane bus module for accommodating the frequency converter

Output frequency Pulse frequency Standard short-circuit breaking current SCCR (Short Circuit Current Rating)2) Concealable frequency range Converter degree of efficiency Interfaces

1, parameterizable 96 % Connection to PROFIBUS (PROFINET available soon) via the ET 200pro backplane bus Optical interface with USS protocol for RS 232 optical connection cable Slot for an optional memory card (MMC) for the upload or download of parameter settings PTC/KTY84 interface for motor temperature monitoring

5/212

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro FC frequency converters

SIMATIC ET 200 distributed I/Os

Technical specifications
ET 200pro frequency converters with integrated safety functions Functions Control process U/f controller- linear (M~n) with/without flow current control (FCC), square (M~n2) or parameterizable Vector control without sensor Torque control Inching, free function blocks (FFB), positioning return ramp, automatic restart after operation interrupted by mains failure, surge-free connection of the converter on rotating motor Regenerative braking operation without brake chopper and pulse resistor Control of an electromechanical holding brake DC 180 V Undervoltage, overvoltage, ground fault, short-circuit, tipping protection, thermal motor protection (I2t, or sensor), converter overheating, motor blocking protection Low-voltage asynchronous motors Motor cable length: max.15 m (shielded) ET 200pro frequency converters with integrated safety functions Mechanical specifications Degree of protection Operating temperature IP65 0 C to +55 C Performance increase at 0 C to +45 C Vertical wall mounting (vertical alignment of cooling fins) 155 x 230 x 213

Mounting position Mounting dimensions (W x H x D) in mm (including terminal module) Weight Standards Standards conformity

Operating functions

4.0 kg UL, cUL, CE, Low-Voltage Directive 73/23/EU, EMC Directive 89/336/EU

Brake functions

1)

Protection functions

The "Safely Limited Speed" and "Safe Stop 1" safety functions are certified for asynchronous motors without sensors these safety functions are not approved for drawing loads such as lifting units and unwinders. Applicable for industrial control cabinet installation acc. to NEC Article 409/UL 508A.

2)

Connectable motors

You can find more information in the Internet at http://support.automation.siemens.com/ ww/view/en/23995621

Derating data pulse frequency


Ambient temperature C 0...55 (1.1 kW) 0...45 (1.5 kW) Rated output current in A at a pulse frequency of 2 kHz 3.5 3.9 4 kHz 3.5 3.9 6 kHz 2.8 3.9 8 kHz 2.2 3.9 10 kHz 1.6 3.4 12 kHz 1.1 3.0 14 kHz 0.5 2.6 16 kHz 2.2

Selection and ordering data


Version ET 200pro frequency converters with integrated safety functions 3 AC 380 V 480 V +10/-10 % 47 Hz 63 Hz Overload: 150 %, 60s, 200 % 3s Power: 1.1 kW (0 55 C) 1.5 kW (0 45 C) ET 200pro FC standard frequency converters 3 AC 380 V 480 V +10/-10 % 47 Hz 63 Hz 150 %, 60s, 200 % 3s Power: 1.1 kW (0 55 C) 1.5 kW (0 45 C) Backplane bus module for accommodating the frequency converter Order No. 6SL3235-0TE21-1SB0

6SL3235-0TE21-1RB0

6SL3260-2TA00-0AA0

Siemens IK PI 2009

5/213

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro FC frequency converters

SIMATIC ET 200 distributed I/Os

Accessories
Following accessories are available:
Description Connector set for energy supply, HanQ4/2 2.5 mm 4.0 mm 6.0 mm Prefabricated single-sided motor cable with plug, shielded, HanQ8 Length 1.5 m Length 3 m Length 5 m Length 10 m Frequency converter plug for motor cable, shielded, HanQ8 Power jumper plugs for 400-V power loop-through connection to the following 400 V modules 6ES7194-1LA01-0AA0 6ES7194-1LB01-0AA0 6ES7194-1LC01-0AA0 6ES7194-1LD01-0AA0 6ES7194-1AB01-0XA0 3RK1922-2BQ00 3RK1911-2BE50 3RK1911-2BE10 3RK1911-2BE30 Order No.

RS 232 interface cables for parameterization of the converter with the STARTER tool via a direct point-to-point connection

3RK1922-2BP00

6SL3254-0AM00-0AA0 Memory card (MMC) for the ET 200S FC and ET 200pro FC parameter settings If required there is space on the memory card (MMC) for the complete parameterization of the frequency converter. For service purposes the system is immediately ready for use after replacement of the frequency converter and acceptance of the memory card.

Dimensions
Clearance required due to heat build-up 50 36 24 Grounding point Mounting rail Bus module

G_D011_EN_00088

230 279.5 Frequency Converter Grounding point 62 248 155

ET 200pro FC frequency converter with backplane bus module and mounting rail

5/214

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro Motor Starters Safety Modules

SIMATIC ET 200 distributed I/Os

Overview

Application
Safety local isolator module The Safety local isolator module features the same functions as a standard isolator module with an additional local safety function. The Safety local isolator module contains a 3TK28 41 module and is equipped with M12 terminals for the connection of external safety components. Terminals 1 and 2 can be used to connect either 1-channel or 2-channel EMERGENCY-STOP circuits or protective door circuits (IN 1, IN 2). For monitored starts, an external START switch can be connected to terminal 3. The required safety functions can be set using 2 slide switches located under the left M12 opening. In the event of an EMERGENCY-STOP, the Safety local isolator module trips the downstream 400 V disconnecting module. This safely isolates the 400 V circuit up to Cat. 4/SIL 3. In combination with the 400 V disconnecting module, the Safety local isolator module can be used for safety applications up to Cat. 4/SIL 3 according to EN 954-1. 400 V disconnecting module The 400 V disconnecting module can be used together with the Safety local isolator module for local safety applications and together with the F-Switch for PROFIsafe safety applications. It contains two contactors connected in series for safety-oriented disconnection of the main circuit. The auxiliary circuit supply of the device is over a safety power rail in the backplane bus module. The 400 V disconnecting module can be used together with the Safety local isolator module or with the F-Switch for safety applications up to Cat. 4/SIL 3 according to EN 954-1. F-Switch The F-Switch is a failsafe solid-state module for PROFIsafe safety applications. It has two failsafe inputs and outputs for safe switching of the 24 V supply over backplane bus bars. In combination with the 400 V disconnecting module it can be used in PROFIsafe applications for the failsafe disconnection of ET 200pro motor starters up to Cat. 4/SIL 3.

Safety local isolator module The Safety local isolator module is a maintenance switch with integrated safety evaluation functions that can be parameterized using DIP switches. It is used for: Connection of a 1 or 2-channel EMERGENCY-STOP circuit up to category 3-4/SIL 3 (protective door or EMERGENCY-STOP pushbuttons) and parameterizable start behavior Control of the 400 V disconnecting module by means of a safety rail signal 400 V disconnecting module The 400 V disconnecting module enables the safe disconnection of the operational voltage of 400 V up to Category 3-4/SIL 3. For operation in a Safety Solution local application it functions only in combination with the Safety local isolator module. For operation in a Safety PROFIsafe application it functions only in combination with the F-Switch. F-Switch Fail-safe digital inputs/outputs in degree of protection IP65/66/67 for near-machine, cabinet-free use. Fail-safe digital inputs For the failsafe reading in of sensor information (1-/2-channel) Including integrated evaluation for 2v2 signals Internal sensor supplies (incl. testing) available Fail-safe digital outputs 3 failsafe PP-switching outputs for safe switching of the backplane bus bars The F-Switch is certified up to Cat. 4 (EN 954-1) and up to SIL 3 (IEC 61508) and has detailed diagnostics. It supports PROFIsafe in PROFIBUS configurations as well as in PROFINET configurations. Note: For safety characteristics for motor starters, see "Appendix" --> "Standards and Approvals" --> "Overview"

Siemens IK PI 2009

5/215

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


ET 200pro Motor Starters Safety Modules

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version Order No.

ET 200pro safety modules


Safety local isolator module1)2) Rated operational current 16 A 3RK1 304-0HS00-7AA0

3RK1 304-0HS00-7AA0

400 V disconnecting module3)4) Rated operational current 25 A 3RK1 304-0HS00-8AA0

3RK1 304-0HS00-8AA0

F-Switch PROFIsafe 24 V DC, including bus module Connection module to be ordered separately 6ES7 148-4FS00-0AB0

6ES7 148-1FS00-0AB0

Connection module for F-Switch 24 V DC


1) 2) 3) 4)

6ES7 194-4DA00-0AA0

The Safety local isolator module only functions when used together with the 400 V disconnecting module. Only in combination with the special backplane bus module for the Safety local isolator module (see "Accessories for ET 200pro motor starters"). The 400 V disconnecting module only functions when used together with the Safety local isolator module or with the F-Switch. Only functions when used together with the backplane bus module and the wide module rack. The backplane bus module and the wide module rack must be ordered separately (see "Accessories for ET 200pro motor starters").

5/216

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


Accessories for ET 200pro motor starters

SIMATIC ET 200 distributed I/Os

Overview
Infeed on isolator module

RSM MS MS MS MS

3 2

7 9

NSA0_00465

NSA0_00467

5 / 6 M M

5
Infeed on the RSM isolator module

Basic design of an ET 200pro motor starter

Legend:

Infeed on ET 200pro motor starter

$ % & ( )

Power feeder plugs (see page 218) Power connection plugs (see page 218) Power jumper plugs (see page 218) Motor connection plugs (see page 218) Motor plugs (see page 218) Motor plugs with EMC suppressor circuit (see page 218) Power loop-through plugs (see page 218) Power connection cables (see page 218) Power connection cables for isolator module (see page 218) Motor cable (see page 218)

MS

MS

) + ,
NSA0_00466

10 8

Infeed on the ET 200pro motor starter

Siemens IK PI 2009

5/217

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


Accessories for ET 200pro motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data


Version Order No.

ET 200pro accessories
$ Power feeder plugs

Connector set for energy supply, e.g. for connecting to T terminal connectors, comprising a coupling enclosure, straight outgoing unit (with bracket), pin insert for HAN Q4/2, incl. gland 5 male contacts 2.5 mm2 5 male contacts 4 mm2 5 male contacts 6 mm2
$ Power connection plugs

3RK1 911-2BS60 3RK1 911-2BS20 3RK1 911-2BS40

Connector set for energy supply for connection to ET 200pro motor starters/ ET 200pro isolator module, comprising a cable-end connector hood, angled outgoing unit, female insert for HAN Q4/2, incl. gland 5 female contacts 2.5 mm2 5 female contacts 4 mm2 5 female contacts 6 mm2
& Power jumper plugs ( Motor connection plugs

3RK1 911-2BE50 3RK1 911-2BE10 3RK1 911-2BE30 3RK1 922-2BQ00

Connector set for motor cable for connection to ET 200pro motor starters, comprising a cable-end connector hood, angled outgoing unit, pin insert for HAN Q8/0, incl. gland 8 male contacts 1.5 mm2 6 male contacts 2.5 mm2
) Motor plugs

3RK1 902-0CE00 3RK1 902-0CC00

Connector set for motor cable for connection to motors, comprising a cable-end connector hood, straight outgoing unit, female insert for HAN 10e, incl. star jumper, incl. gland 7 female contacts 1.5 mm2 7 female contacts 2.5 mm2
) Motor plugs with EMC suppressor circuit

3RK1 911-2BM21 3RK1 911-2BM22

Connector set for motor cable for connection to motors, comprising a cable-end connector hood, straight outgoing unit, female insert for HAN 10e with EMC suppressor circuit, incl. star jumper, incl. gland 7 female contacts 1.5 mm2 7 female contacts 2.5 mm2
+ Power loop-through plugs

3RK1 911-2BL21 3RK1 911-2BL22

Connector set for power loop-through for connection to ET 200pro motor starters/ET 200pro isolator module, comprising a cable-end connector hood, angled outgoing unit, pin insert for HAN Q4/2, incl. gland 4 male contacts 2.5 mm2 4 male contacts 4 mm2
, Power connection cables, assembled at one end

3RK1 911-2BF50 3RK1 911-2BF10

Power connection cable for ET 200pro motor starters, ECOFAST, open at one end, for HAN Q4/2, angled, insert turned at isolator module end, 4 x 4 mm2 Length 1.5 m Length 5.0 m
- Power connection cables for isolator module, assembled at one end

3RK1 911-0DB13 3RK1 911-0DB33

Power connection cable for ET 200pro isolator module, open at one end, for HAN Q4/2, angled, insert turned at isolator module end, 4 x 4 mm2 Length 1.5 m Length 5.0 m
, Motor cables, assembled at one end

3RK1 911-0DF13 3RK1 911-0DF33

open at one end, HAN Q8, angled, length 5 m Motor cable for motor without brake, for ET 200pro, ET 200X, AS-i Compact, 4 x 1.5 mm2 Motor cable for motor with brake, for ET 200pro, 6 x 1.5 mm2 3RK1 911-0EB31 3RK1 911-0ED31

More connection technology products can be found at our "Siemens Solution Partners" www.siemens.com/automation/partnerfinder under the "Distributed Field Installation System" technology

5/218

Siemens IK PI 2009

Siemens AG 2008

ET 200pro Motor Starters and Frequency Converters


Accessories for ET 200pro motor starters

SIMATIC ET 200 distributed I/Os

Selection and ordering data (continued)


Version Order No.

ET 200pro accessories
Module racks, wide1) Length 500 mm Length 1000 mm Length 2000 mm Module racks, wide, compact1) Length 500 mm Length 1000 mm Length 2000 mm Backplane bus module 110 mm2) Backplane bus module for Safety local isolator module RS 232 interface cables Hand-held device For ET 200pro motor starters, (also for ET 200S High Feature and ECOFAST), for local operation. A serial interface cable must be ordered separately. Sealing caps (for power supply) (1 pack contains 10 units) Dismantling tools for HAN Q4/2 Crimping tools for pins/sockets 4 mm2 and 6 mm2
3RK1 922-3BA00

6ES7 194-4GB00-0AA0 6ES7 194-4GB60-0AA0 6ES7 194-4GB20-0AA0 6ES7 194-4GD00-0AA0 6ES7 194-4GD10-0AA0 6ES7 194-4GD20-0AA0 3RK1 922-2BA00 3RK1 922-2BA01 3RK1 922-2BP00 3RK1 922-3BA00

3RK1 902-0CJ00 3RK1 902-0AB00 3RK1 902-0CW00 3RK1 902-0CT00 3RK1 902-0AJ00 3RX9 802-0AA00

Crimping tools for male contacts and sockets up to 4.0 mm2 (HAN Q8/0) Dismantling tools for male contacts and sockets (HAN Q8/0) M12 sealing cap For sealing unused input and output sockets (one set contains ten sealing caps)

1)

2)

The wide module rack can accommodate all ET 200pro motor starters and any optional modules (isolator module, Safety local isolator module and 400 V disconnecting module). The backplane bus module is a prerequisite for operation of the ET 200pro motor starter and the optional module.

Siemens IK PI 2009

5/219

Siemens AG 2008

ET 200pro Software
Motor Starter ES

SIMATIC ET 200 distributed I/Os

Overview
Motor Starter ES for parameterization, monitoring, diagnostics and testing of motor starters Note: More information about ES Motor Starters, see Chapter 9.

Selection and ordering data


Version Motor Starter ES 2007 Basic Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Motor Starter ES 2007 Standard Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Motor Starter ES 2007 Premium Floating license for one user E-SW, software and documentation on CD, 3 languages (German/English/French), communication through system interface License key on USB stick, Class A, including CD Accessories For ET 200S High Feature motor starters Control module 2DI DC 24 V COM, for ET 200S High-Feature starter, Failsafe Starter A LOGO! PC cables For ET 200pro motor starters RS 232 interface cable, serial data connection between ET 200pro MS/FC and laptop/PC/PG or MS For ECOFAST High Feature motor starters (interface cable) PC cables USB/serial adapter To connect the PC cable to the USB port of a PC, we recommend, in conjunction with 3RW44 soft starter, using SIMOCODE pro 3UF7, 3RK3 modular safety system, ET 200S/ECOFAST/ET 200pro motor starter, AS-i safety monitor, AS-i analyzer 3RK1 903-0CH10 6ED1 057-1AA00-0BA0 3RK1 922-2BP00 Order No.

3ZS1 310-4CC10-0YA5

3ZS1 310-5CC10-0YA5

3ZS1 310-6CC10-0YA5

3RK1 911-0BN20 3UF7 946-0AA00-0

5/220

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200L
ET 200L

Design
Terminal block The terminal block accommodates the electronic module. It carries the wiring, so that no cables need to be separated when the electronic module is replaced. The terminal block can be mounted on a standard rail. In addition to horizontal mounting all other mounting positions are permissible. A total of 4 terminal blocks are available for SIMATIC ET 200L: 16 channels with screw-type terminals or spring-type terminals 32 channels with screw-type terminals or spring-type terminals Electronic module The electronic modules contain the digital input and output channels.
ET 200L block I/O (with 16 channels)

The SIMATIC ET 200L compact I/O station comprises one terminal block and one electronic module Connection to the PROFIBUS DP field bus is through the interface integrated in the electronic module. The ET 200L block I/O is not expandable.

The following digital electronic modules are available for 24 V DC: 16 DI; with 16 digital inputs 16 DO; with 16 digital outputs, 0.5 A 32 DI; with 32 digital inputs 32 DO; with 32 digital outputs, 0.5 A 16 DI/16 DO; with 16 digital inputs and outputs, 0.5 A. Blocks for AC: 16 DO/1 A 16 DO/ 2 A 16 DI 8 DI/8 RO/2 A PROFIBUS DP station address The address of the compact ET 200L I/O station is set on the electronic module by way of a rotary coding switch. Bus line termination: If the ET 200L is used at the end of a bus segment, it requires a bus connector with terminating resistance. Accessories Perforated labeling sheets (DIN A4) suitable for machine printing are available as accessories. The terminal blocks come with 2-wire connection as standard. Optional supplementary terminals enable the use of 3-wire or 4-wire connections.

Siemens IK PI 2009

5/221

Siemens AG 2008

ET 200L
ET 200L

SIMATIC ET 200 distributed I/Os

Technical specifications
Order No. Supply voltages Rated value DC 24 V Reverse polarity protection Hardware config. Rack Required terminal block Connection point Inputs/outputs Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection 1.5 MBit/s Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) 16 1 000 m Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection 1.5 MBit/s Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) 32 1 000 m Shock test 24 V -30 to +5 V 13 to 30 V 5 mA 24 V -30 to +5 V 13 to 30 V Degree and class of protection 5 mA IP 20 Yes Yes checked according to IEC 60068-2-27 Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms TB 16L TB 32L Yes Yes Yes Yes 6ES7 1311BH01-0XB0 6ES7 1311BL01-0XB0 Order No. Isolation between PROFIBUS DP all all other circuits Galvanic isolation, digital inputs between the channels between the channels and PROFIBUS DP Environmental requirements Operating termperature horizontal installation, min. horizontal installation, max. Air pressure permissible range, min. permissible range, max. Relative humidity Operation, min. Operation, max. 5% 5% 95%; RH class 95%; RH class 2 in accordance 2 in accordance with IEC 1131-2 with IEC 1131-2 Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) 795 hPa 1 080 hPa 795 hPa 1 080 hPa 0 C 0 C 60 C; 40C for 60 C; 40C for other mountings other mountings No Yes No Yes Yes Yes 6ES7 1311BH01-0XB0 6ES7 1311BL01-0XB0

PROFIBUS DP Transmission speed, max. direct data exchange (cross traffic)

Vibrations Operation checked according to IEC 60068-2-6

Digital inputs Number of digital inputs Cable length Cable length for NAMUR input, shielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. 2 ms 4.5 ms 2 ms 4.5 ms

5/222

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200L
ET 200L

Technical specifications (continued)


Order No. Supply voltages Rated value DC 24 V Reverse polarity protection Voltages and currents Mains/voltage failure jumpering, min. Load voltage 2L+ Rated value (DC) Current consumption from load voltage L1 (without load), max. from supply voltage L+, max. Power loss, typ. Hardware config. Rack Required terminal block Communication functions Bus protocol/transmission protocol Connection point Inputs/outputs Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection 1.5 MBit/s Yes Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) 16 1 000 m 600 m 0.7 A typ. (L1+ or L2+ / L3+) -55 V 5W Yes 24 V Ua - 3 V 0.5 A Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection 1.5 MBit/s Yes Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) 32 1 000 m 600 m Yes; Electronic 0.7 A typ. (L1+ or L2+ / L3+) -55 V 5W Yes 24 V Ua - 3 V 0.5 A 1 mA Siemens IK PI 2009 PROFIBUS DP PROFIBUS DP TB 16L TB 32L 50 mA; per load group (L1+ or L2+ / L3+) 70 mA; L4+ / L5+ 5W 100 mA; per load group (L1+ or L2+ / L3+) 70 mA; L4+ / L5+ 7W 24 V; 1L+, 2L+, 3L+ 24 V; 1L+, 2L+, 3L+ Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) all other mounting positions - up to 40 C, max. up to 60 C, max. horizontal arramgement, to 40 C, max. horizontal arrangement, to 60 C, max. Load impedance range lower limit upper limit Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Bus error BF (red) Status indicator digital output (green) Status indicator digital input (green) Yes Yes Yes Yes Yes Yes Yes Yes Yes No No 41 28 000 41 28 000 2A 4A 3 000 mA 2 000 mA 2A 4A 3 000 mA 2 000 mA 100 Hz 0.5 Hz 8 Hz 100 Hz 0.5 Hz 8 Hz 20 ms 20 ms Yes Yes Yes Yes 6ES7 1321BH00-0XB0 6ES7 1321BL00-0XB0 Order No. Output delay with resistive load "0" to "1", max. "1" to "0", max. Parallel switching of 2 outputs for increased power for redundant control of a load No No Yes; Yes; only outputs of only outputs of the same group the same group 50 ms 200 ms 50 ms 200 ms 6ES7 1321BH00-0XB0 6ES7 1321BL00-0XB0

PROFIBUS DP Transmission speed, max. SYNC capability direct data exchange (cross traffic)

Monitoring 24 V voltage supply ON Yes (green) Isolation Isolation checked with Isolation between PROFIBUS DP all all other circuits Isolation, digital outputs between the channels between the channels and PROFIBUS DP Environmental requirements Operating termperature horizontal installation, min. horizontal installation, max. 0 C No Yes; Optocoupler Yes 500 VDC

Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage Rated value (DC) for signal "1", min. Output current for signal "1" permissible range for 0 to 60 C, max.

500 VDC Yes

Short-circuit protection of the output Yes; Electronic

No Yes

0 C

60 C; 40C for 60 C; 40C for other mountings other mountings

for signal "0" residual current, max. 1 mA

5/223

Siemens AG 2008

ET 200L
ET 200L

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Air pressure permissible range, min. permissible range, max. Relative humidity Operation, min. Operation, max. 5% 5% 95%; RH class 95%; RH class 2 in accordance 2 in accordance with IEC 1131-2 with IEC 1131-2 Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms Yes 0016h Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms Yes 0011h 795 hPa 1 080 hPa 795 hPa 1 080 hPa 6ES7 1321BH00-0XB0 6ES7 1321BL00-0XB0 Order No. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. Digital outputs Number of digital outputs cable length, shielded, max. Output voltage Rated value (DC) for signal "1", min. Output current for signal "1" permissible range for 0 to 60 C, max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. 145 mm 60 mm 60.5 mm 130 g 145 mm 60 mm 60.5 mm 150 g up to 60 C, max. Isolation between PROFIBUS DP all all other circuits Galvanic isolation, digital inputs between the channels Order No. Supply voltages Rated value DC 24 V Reverse polarity protection Hardware config. Rack Required terminal block Connection point Inputs/outputs Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection 1.5 MBit/s Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) 16 1 000 m TB 32L Yes Yes 6ES7 133-1BL01-0XB0 between the channels and PROFIBUS DP Environmental requirements Operating termperature horizontal installation, min. horizontal installation, max. Air pressure permissible range, min. permissible range, max. Relative humidity Operation, min. Operation, max. Vibrations Operation checked according to IEC 60068-2-6 Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms Yes 5% 95%; RH class 2 in accordance with IEC 1131-2 795 hPa 1 080 hPa 0 C 60 C; 40C for other mountings No Yes Yes 100 Hz 0.5 Hz 8 Hz 4A 0.5 mA 24 V Ua - 3 V 16 1 000 m 2 ms 4.5 ms 5 mA 24 V -30 to +5 V 13 to 30 V 6ES7 133-1BL01-0XB0

Vibrations Operation checked according to IEC 60068-2-6

Short-circuit protection of the output Yes; Electronic

Shock test checked according to IEC 60068-2-27

Degree and class of protection IP 20 General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx.

for signal "0" residual current, max. 1 mA

PROFIBUS DP Transmission speed, max. direct data exchange (cross traffic)

Digital inputs Number of digital inputs Cable length Cable length for NAMUR input, shielded, max.

Shock test checked according to IEC 60068-2-27 Degree and class of protection IP 20

5/224

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200L
ET 200L

Technical specifications (continued)


Order No. Dimensions Dimensions Width Height 145 mm 100 mm; Height with electronics block from top edge of DIN rail (with bus connector ): 6ES7 972-0CA300XA0): 82 mm 40.5 mm 230 g 145 mm 100 mm; Height with electronics block from top edge of DIN rail (with bus connector ): 6ES7 972-0CA300XA0): 82 mm 40.5 mm 230 g 191 mm 100 mm; Height with electronics block from top edge (with bus connector ): 98.5 mm 191 mm 100 mm; Height with electronics block from top edge of DIN rail (with bus connector ): 6ES7 972-0CA300XA0): 82 mm 40.5 mm 350 g 191 mm 100 mm; Height with electronics block from top edge of DIN rail (with bus connector ): 6ES7 972-0CA300XA0): 82 mm 40.5 mm 350 g 6ES7 193-1CH000XA0 6ES7 193-1CH100XA0 6ES7 193-1CH200XA0 6ES7 193-1CL000XA0 6ES7 193-1CL100XA0

Depth Weights Weight, approx.

40.5 mm 283 g

Ordering data
Electronic block for ET 200L With digital inputs/outputs for 24 V DC 16 DI 32 DI 16 DO; 0.5 A 32 DO; 0.5 A 16 DI/16 DO; 0.5 A Terminal block for ET 200L and ET 200L-SC For mounting the electronic blocks TB 16L 16 channels, screw-type terminals 16 channels, spring-loaded terminals TB 32L 32 channels, screw-type terminals 32 channels, spring-loaded terminals TB 16L AC 16 channels, screw-type terminals Add-on terminal for ET 200L and ET 200L-SC 16 channels; 1 tier Screw-type terminals Spring-loaded terminals 16 channels; 2 tiers Screw-type terminals Spring-loaded terminals 32 channels; 1 tier Screw-type terminals Spring-loaded terminals 32 channels; 2 tiers Screw-type terminals Spring-loaded terminals

Order No. Accessories Labeling sheet with strips for 10 electronic blocks for 6ES7 131-1BH01-0XB0 6ES7 131-1BL01-0XB0 6ES7 132-1BH00-0XB0 6ES7 132-1BL00-0XB0 6ES7 133-1BL01-0XB0 16-channel electronic blocks incl. add-on terminals 32-channel electronic blocks incl. add-on terminals RS485 bus connector with cable outlet (90) for FastConnect connection technology max.data transmission rate 12 Mbit/s without PG socket 6ES7 193-1CH00-0XA0 6ES7 193-1CH10-0XA0 with PG socket RS485 bus connector with angled cable outlet max. data transmission rate 12 Mbit/s, insulation displacement terminals insulation displacement termination, without bus termination resistance, without PG connection socket

Order No.

5
6ES7 193-1BH00-0XA0 6ES7 193-1BL00-0XA0

6ES7 972-0BA51-0XA0 6ES7 972-0BB51-0XA0

6ES7 972-0BA30-0XA0

6ES7 193-1CL00-0XA0 6ES7 193-1CL10-0XA0

6ES7 193-1CH20-0XA0

6ES7 193-1FH20-0XA0 6ES7 193-1FH50-0XA0 6ES7 193-1FH30-0XA0 6ES7 193-1FH60-0XA0 6ES7 193-1FL20-0XA0 6ES7 193-1FL50-0XA0 6ES7 193-1FL30-0XA0 6ES7 193-1FL60-0XA0

Siemens IK PI 2009

5/225

Siemens AG 2008

ET 200M
ET 200M

SIMATIC ET 200 distributed I/Os

Application

Technical specifications General


Cables and connections Screw connection, spring-loaded connection and FastConnect with permanent wiring IP20

Degree of protection Ambient temperature on vertical wall (preferred mounting position) with horizontal assembly with other assembly Relative humidity Atmospheric pressure Mechanical stress Vibrations

0 +60 C 0 +40 C 5 95% (RH stress level 2 according to IEC 1131-2) 795 1080 hPa IEC 68, parts 2 - 6: 10 57 Hz (constant amplitude 0.075 mm) 57 150 Hz (constant acceleration 1 g) IEC 68, parts 2 - 27 half-sine, 15 g, 11 ms

Modular I/O system with degree of protection IP20, particularly suitable for user-specific and complex automation tasks Can be expanded with S7-300 automation system signal, communication and function modules Applicable Ex analog input or output modules with HART optimize the ET 200M for use in process engineering Can be used in redundant systems (S7-400H, S7-400F/FH) Consists of a PROFIBUS DP IM 153 connection, up to eight or twelve I/O modules of the S7-300 automation system (assembly with bus connections or active bus modules) and if required a power supply Modules can be replaced during operation (hot swapping) with the bus modules active Can be supplied with integrated fiber optic interface if required Transmission rates up to 12 Mbit/s Ex approval to Cat. 3 for Zone 2 acc. to ATEX100 a Failsafe digital in/outputs as well as analog inputs for safetyoriented signal processing in accordance with PROFIsafe Support of modules with expanded user data, e.g. HART modules with HART minor variables

Shock

5/226

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M

IM 153-1/153-2

Overview
IM 153-1 Standard The IM 153-1 is one reasonably priced version that is best suited for most applications in the manufacturing environment. It permits the use of up to eight S7-300 I/O modules. IM 153-2 High Feature For higher requirements in manufacturing technology, such as the use of F-technology or the highest performance in conjunction with clock synchronization, the IM 153-2 High Feature is available. This IM is also designed for use with the PCS 7 in the field of manufacturing applications. This IM can be redundantly used and supports typical functions as they are required in the control field. These include, for example, clock synchronization or time stamping with an accuracy of up to 1ms. IM 153-2 High Feature FO The High Feature version (with reduced scope of services) is also available as an FO version. This permits fiber optic cables to be connected in the POF or the PCF, and is therefore particularly well suited for use in the heavily EMC-charged areas.

The ET 200M system with various interface modules is available for the decentralized use of S7-300 I/O modules. Depending on the application purpose, the best suited IM in terms of costs and functions can be selected:

Technical specifications
Order No. Power supply Input current Rated value at DC 24 V Output voltage Rated value, DC 5 V Output current for backplane bus (DC 5 V), max. Supply voltages Rated value DC 24 V Permissible range (ripple included), lower limit (DC) permissible range (ripple included), upper limit (DC) Power supply and voltage jumpering Mains/voltage failure jumpering Voltages and currents external protection for supply cables (recommendation) Current consumption Inrush current, typ. It Current consumption, max. Power loss, typ. Address area Adressing volume Outputs Inputs 128 Byte 128 Byte 244 Byte 244 Byte 244 Byte 244 Byte 128 Byte 128 Byte 2.5 A 0.1 As 350 mA; At 24 V DC 3W 3A 0.1 As 600 mA 5.5 W 3A 0.1 As 600 mA 5.5 W 3.5 A 0.1 As 500 mA; At 24 V DC 4.5 W not necessary 2.5A 2.5A not necessary 5 ms 20 ms 20 ms 20.4 V 28.8 V Yes 20.4 V 28.8 V Yes 20.4 V 28.8 V Yes 20.4 V 28.8 V 1A 1.5 A 1A Yes Yes Yes 625 mA 6ES7 153-1AA03-0XB0 6ES7 153-2BA02-0XB0 6ES7 153-2BA82-0XB0 6ES7 153-2BB00-0XB0

Siemens IK PI 2009

5/227

Siemens AG 2008

ET 200M

SIMATIC ET 200 distributed I/Os

IM 153-1/153-2

Technical specifications (continued)


Order No. Hardware config. Number of modules per DP slave interface, max. Communication functions Bus protocol/transmission protocol interfaces PROFIBUS DP, Output current, max. 90 mA interface physics, RS 485 interface physics, LWL Connection point PROFIBUS DP PROFIBUS DP Transmission procedure Transmission speed, max. RS 485 12 MBit/s RS 485 12 MBit/s RS 485 12 MBit/s LWL, wavelength 660 nm 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 12 Mbit/s 1 to 125 permitted Yes Yes Yes Yes; Sender 9-pin Sub-D socket optical, 2 x duplex sockets Yes No 70 mA Yes No 70 mA Yes No No Yes PROFIBUS DP to EN 50170 PROFIBUS DP to EN 50170 PROFIBUS DP PROFIBUS DP to EN 50170 8 12 12 8 6ES7 153-1AA03-0XB0 6ES7 153-2BA02-0XB0 6ES7 153-2BA82-0XB0 6ES7 153-2BB00-0XB0

5
Node addresses automatic detection of transmission speed SYNC capability FREECE capability direct data exchange (cross traffic) 1st interface DP slave GSD file (for DPV1) SIEM801D.GSD; SI01801D.GSG SI04801.GSG SI0480E.GSG 1 to 125 permitted Yes Yes Yes Yes; Sender 1 to 125 permitted Yes Yes Yes Yes; Sender 1.125 Yes Yes Yes Yes

(for DPV1) SIEM8071.GSD; SI018071.GSG (for IM 153-2AB0x); SI028071.GSG (for IM 153-2BB0x) Yes

automatic baud rate search CPU/programming Configuration software STEP 7

Yes

Yes

Yes

STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file

Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file

Yes

Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file

Time stamping Accuracy 1 ms; 1 ms; 10 ms; 1ms at up to 8 modules; 1ms at up to 8 modules; 10 ms / 3 ms 10ms at up to 12 modules 10ms at up to 12 modules 15 20 128; Max. 128 signals / station; max. 32 signals / slot RFC 1119 0.466 ns 0.466 ns 128; 128 signals / station; max. 32 signals / slot 128

Number of message buffers Messages per message buffer Number of stampable digital inputs, max. Time format Time resolution Time interval for transmitting the message buffer if a message is present Time stamp on signal change rising / falling edge as signal entering or exiting Yes

RFC 1119 Internet (ISP) 1 ms 1 000 ms

rising / falling edge as signal entering or exiting

5/228

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M

IM 153-1/153-2

Technical specifications (continued)


Order No. Isolation Isolation checked with Environmental requirements Operating termperature min. max. Air pressure Operating height above sea level, max. Degree and class of protection IP 20 General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Accessories belongs to product Weights Weight, approx. Order No. 133 g 6ES7 1957HA000XA0 111 g 6ES7 1957HB000XA0 140 g 6ES7 1957HC000XA0 127 g ET 200M 360 g 6ES7 195-7HD10-0XA0 360 g 360 g 360 g 40 mm 125 mm 117 mm 40 mm 125 mm 117 mm 40 mm 125 mm 117 mm 40 mm 125 mm 117 mm 801Dh 801E 801E 8071h Yes Yes Yes Yes 3 000 m 3 000 m 3 000 m 3 000 m 0 C 60 C 0 C 60 C -25 C 60 C 0 C 60 C Isolation voltage 500 V Isolation voltage 500 V 500 VDC Isolation voltage 500 V 6ES7 153-1AA03-0XB0 6ES7 153-2BA02-0XB0 6ES7 153-2BA82-0XB0 6ES7 153-2BB00-0XB0

Weights Weight, approx.

Siemens IK PI 2009

5/229

Siemens AG 2008

ET 200M

SIMATIC ET 200 distributed I/Os

IM 153-1/153-2

Ordering data
IM 153-1 interface module Slave interface for connecting an ET 200M to PROFIBUS DP Standard temperature range IM 153-2 interface module Slave interface for connecting an ET 200M to PROFIBUS DP; also for use in redundant systems High Feature High Feature with extended temperature range Fiber optic Active IM 153 /IM 153 bus module For two IM 153-2 High Feature modules for designing redundant systems Bus module for ET 200M To accommodate a power supply and an IM 153 module for the hot-swapping function during RUN time including bus module cover To accommodate two 40-mm wide I/O modules for the hot-swapping function To accommodate one 80-mm wide I/O module for the hot-swapping function ET 200M redundancy bundle Comprising two IM 153-2 High Feature modules and one IM 153/IM 153 bus module

Order No. Accessories PROFIBUS bus connector 6ES7 153-1AA03-0XB0 90 outgoing cable, terminating resistor with disconnecting function, without PG connection socket, up to 12 Mbit/s, FastConnect 90 outgoing cable, terminating resistor with disconnecting function, with PG connection socket, up to 12 Mbit/s, FastConnect SIMATIC DP DIN rail for ET 200M For insertion of up to 5 bus modules for Length: 483 mm (19) Length: 530 mm SIMATIC S7-300 DIN rail 6ES7 195-7HA00-0XA0 Length: 160 mm Length: 480 mm (19) Length: 530 mm Length: 830 mm 6ES7 195-7HB00-0XA0 Length: 2,000 mm S7 Manual Collection 6ES7 195-7HC00-0XA0 Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No.

6ES7 972-0BA51-0XA0

6ES7 972-0BB51-0XA0

6ES7 153-2BA02-0XB0 6ES7 153-2BA82-0XB0 6ES7 153-2BB00-0XB0 6ES7 195-7HD10-0XA0

6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 6ES7 998-8XC01-8YE0

6ES7153-2AR03-0XA0

6ES7 998-8XC01-8YE2

5/230

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M

SIPLUS IM 153-1/153-2 (extended temperature range)

Overview
For connecting ET 200M as a slave to PROFIBUS DP (via copper conductors) IM 153-2 also for use in redundant PROFIBUS DP systems with S7-400H, software redundancy and S5-155H With time stamp functionality and time synchronization Suitable for isochronous mode

SIPLUS IM 153-1 Order No. Order No. based on Ambient temperature range 6AG1 153-1AA03-2XB0 6ES7 153-1AA03-0XB0 -25 ... +60 C Condensation permissible

SIPLUS IM 153-2 6AG1 153-2BA02-7XB0 6ES7 153-2BA02-0XB0 -25 ... +70 C -25 ... +60 C (for applications with cUL approval), condensation permissible CE No

Environmental conditions Approvals Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical data

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) CE, UL haz. Loc. Yes

The technical data are identical with those of the based-on modules.

SIPLUS bus module Order No. Order No. based on Ambient temperature range Environmental conditions Approvals Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical data

for accommodating an 80 mm module 6AG1 195-7HC00-2XA0 6ES7 195-7HC00-0XA0 -25 ... +60 C Condensation permissible

for accommodating two IM 153-2 6AG1 195-7HD10-2XA0 6ES7 195-7HD10-0XA0

for accommodating a PS and an IM 153 6AG1 195-7HA00-2XA0 6ES7 195-7HA00-0XA0

Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) CE, cUL (available soon) No No No

The technical data are identical with those of the based-on modules.

Siemens IK PI 2009

5/231

Siemens AG 2008

ET 200M

SIMATIC ET 200 distributed I/Os

SIPLUS IM 153-1/153-2 (extended temperature range)

Overview (continued)
SIPLUS bus module Order No. Order No. based on Ambient temperature range For accommodating two 40 mm wide I/O modules 6AG1 195-7HB00-7XA0 6ES7 195-7HB00-0XA0 -25 ... +70 C -25 ... +60 C (for applications with cUL approval) Condensation permissible Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) CE, UL haz. Loc. No

Ordering data
IM 153-1 interface module Slave interface for connecting an ET 200M to PROFIBUS DP Standard temperature range IM 153-2 interface module Slave interface for connecting an ET 200M to PROFIBUS DP; also for use in redundant systems High Feature Active IM 153/IM 153 bus module For two IM 153-2 High Feature modules for designing redundant systems Bus module for ET 200M The technical data are identical with those of the based-on modules. To accommodate a power supply and an IM 153 for the hot-swapping function during RUN, incl. bus module cover To accommodate two 40 mm wide I/O modules for the hot-swapping function To accommodate one 80 mm wide I/O module for the hot swapping function Accessories

Order No.

6AG1 153-1AA03-2XB0

Environmental conditions

6AG1 153-2BA02-7XB0 6AG1 195-7HD10-2XA0

Approvals Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical data

6AG1 195-7HA00-2XA0

For further technical documentation on SIPLUS, see: http://www.siemens.com/siplus-techdocu

6AG1 195-7HB00-7XA0

6AG1 195-7HC00-2XA0

see IM 153-1/153-2 ordering data

5/232

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M

IM 153-4 PN

bersicht

Technical specifications
Order No. Supply voltages Rated value DC 24 V Power supply and voltage jumpering Mains/voltage failure jumpering Current consumption Current consumption, max. Power loss, typ. Address area Adressing volume Outputs Inputs Hardware config. 192 Byte 192 Byte 12 600 mA 6W 5 ms Yes 6ES7 153-4AA00-0XB0

To connect ET 200M to PROFINET IO (via copper line, RJ45) as an IO device Integrated 2-port switch 12 modules per station Usable I/O capacity: 192 bytes each Active bus backplane to hot-swap modules available as an option Baud rate 10 Mbit/s / 100 Mbit/s (autonegotiation / full duplex) I&M functions in accordance with PROFIBUS International guidelines order no. 3.502, version V1.1 Micro Memory Card with at least 64 KB required.

Number of modules per DP slave interface, max. Communication functions Bus protocol/transmission protocol Status information/ alarms/diagnostics Diagnostics indication LED Connection to network LINK (green) Transmit/receive RX/TX (yellow) Environmental requirements Operating termperature min. max. Degree and class of protection IP 20 Dimensions Dimensions Width Height Depth Weights Weight, approx.

PN IO

Yes Yes

0 C 60 C Yes

40 mm 125 mm 118 mm 215 g

Siemens IK PI 2009

5/233

Siemens AG 2008

ET 200M

SIMATIC ET 200 distributed I/Os

IM 153-4 PN

Ordering data
IM 153-4 PN interface module I/O device to connect an ET 200M to PROFINET Accessories Bus modules for ET 200M To accommodate a power supply and an IM 153 for the hot-swapping function during RUN, incl. bus module cover To accommodate two 40-mm wide I/O modules for the hot-swapping function To accommodate one 80-mm wide I/O module for the hot-swapping function SIMATIC Micro Memory Card 64 KB1) SIMATIC DP DIN rail for ET200M

Order No. 6ES7 153-4AA00-0XB0 Accessories (continued) Compact Switch Module CSM 377 Unmanaged switch for the connection of a SIMATIC S7-300, ET200M and as many as three other nodes to an Industrial Ethernet operating at 10/100 Mbit/s; 4 x RJ45 ports; external 24 V DC power supply, LED diagnostics, S7-300 module incl. electronic equipment manual on CD-ROM Industrial Ethernet Switch SCALANCE X208 managed Switch with integrated SNMP access, Web diagnostics, copper cable diagnostics and PROFINET diagnostics for configuring line, ring and ring structures; with integrated redundancy manager; with eight 10/100 Mbit/s RJ45 ports Industrial Ethernet FC RJ45 Plug 180 RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables; with 180 cable outlet 1 unit 10 units 50 units Industrial Ethernet FastConnect installation cables Fast Connect standard cable Fast Connect trailing cable Fast Connect marine cable Industrial Ethernet FastConnect Stripping Tool 6ES7 998-8XC01-8YE2

Order No.

6GK7 377-1AA00-0AA0

6ES7 195-7HA00-0XA0

6ES7 195-7HB00-0XA0

6ES7 195-7HC00-0XA0

6GK5 208-0BA10-2AA3

6ES7 953-8LF20-0AA0

For insertion of up to 5 bus modules for Length: 483 mm (19) Length: 530 mm SIMATIC S7-300 DIN rail Length: 160 mm Length: 480 mm (19) Length: 530 mm Length: 830 mm Length: 2,000 mm S7 Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates
1)

6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 6ES7 998-8XC01-8YE0

6GK1 901-1BB10-2AA0 6GK1 901-1BB10-2AB0 6GK1 901-1BB10-2AE0

6XV1 840-2AH10 6XV1 840-3AH10 6XV1 840-4AH10 6GK1 901-1GA00

To operate the IM153-4, an MMC is required with at least 64 KB memory. Cards with higher memory capacity may also be used.

5/234

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 326 F digital input module Safety Integrated

Overview
Digital inputs for the fail-safe SIMATIC S7 systems They are suitable for connecting: - Switches and 2-wire proximity switches (BEROs) - Sensors according to NAMUR and mechanical contacts, also for signals from hazardous areas With integral safety functions for fail-safe operation Can be used in fail-safe mode - Centrally: With S7-31xF-2 DP - Distributed in ET 200M: With SIMATIC IM 151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH Can be used in standard mode as an S7-300 module

Technical specifications
Order No. Supply voltages Supply voltage of electronics and encoders 1L+/2L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital inputs Number of digital inputs 8; 8 (one-channel) 4 (two-channel) 24 40-pin 40-pin 160 mA 90 mA 4.5 W 450 mA 100 mA 10 W permissible quiescent current (2-wire BEROS), max. Ex(i) characteristics Module for Ex(i) protection Max. values of input circuits (per channel) Co (permissible external capacity), max. 8; vertical setup 24 8; horizontal set up 200 m 100 m 24; (at 24 V) or 18 (at 28.8 V) 200 m 100 m 24 V -30 to +5 V 11 to 30 V 2 mA 2.1 to 7 mA 10 mA Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Uo (output no-load voltage), max. Ta (permissible ambient temperature), max. Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostic information readable Isolation Isolation checked with 500 VDC 500 V DC / 350 V AC Yes Yes Yes Yes 3 F 13.9 mA 80 milliH 33.1 mW 10 V 60 C 60 C Yes 24 V 24 V 6ES7 3261RF00-0AB0 6ES7 3261BK01-0AB0 Order No. Encoder supply Number of outputs Output voltage Output current, rated value Encoder Connectable encoders 2-wire BEROS Yes; if shortcircuit test is deactivated 2 mA 8 8.2 V DC 400 mA 4; isolated 6ES7 3261RF00-0AB0 6ES7 3261BK01-0AB0

Number of simultanneously controllable inputs Number of simultaneously controllable inputs, up to 40 C Number of simultaneously controllable inputs, up to 60 C Cable length cable length, shielded, max. Cable length unshielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. - at "1" to "0", max. 3.4 ms 3.4 ms

Siemens IK PI 2009

5/235

Siemens AG 2008

ET 200M F Digital/Analog Modules


Technical specifications (continued)
Order No. Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Test number KEMA Highest safety class achievable in safety mode to DIN VDE 0801 AK 4 (one chan- AK 6 nel), AK 5 und 6 (two channel) Cat. 3 (singlechannel), Cat. 4 (two-channel) SIL 2 (singlechannel), SIL 3 (two-channel) Order No. Cat. 4 II(2)G [EEx ib] IIC to EN 50020 99 ATEX 2671 X Yes Yes Yes 12 Yes 6ES7 3261RF00-0AB0

SIMATIC ET 200 distributed I/Os

SM 326 F digital input module Safety Integrated

6ES7 3261BK01-0AB0

Order No. Dimensions Dimensions Width Height Depth Weights Weight, approx.

6ES7 3261RF00-0AB0

6ES7 3261BK01-0AB0

80 mm 125 mm 120 mm 482 g

80 mm 125 mm 120 mm 442 g

to EN 954

to IEC 61508

SIL 3

Ordering data
F digital input module SM 326 24 inputs, 24 V DC 8 inputs, 24 V DC, NAMUR Distributed Safety V5.4 programming tool Task: Software for configuring fail-safe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade From V5.x to V5.4; Floating license for 1 user Labeling sheet with strips for 10 electronic blocks For 16-channel electronic blocks incl. add-on terminals For 32-channel electronic blocks incl. add-on terminals Connecting cable for PROFIBUS 12 Mbit/s, for connecting PG to PROFIBUS DP, pre-assembled with 2 x 9-pin Sub-D connector, 3m

Order No. PROFIBUS bus connector

6ES7 326-1BK01-0AB0 6ES7 326-1RF00-0AB0

90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, with PG socket, up to 12 Mbit/s DIN rail for active bus modules for max. 5 active bus modules for hot swapping function 483 mm (19") long 530 mm long 620 mm long 2000 mm long Active bus module BM 1 x 80 for 1 module with 80 mm width

6ES7 972-0BA12-0XA0

6ES7 972-0BB12-0XA0

6ES7 972-0BA51-0XA0

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

6ES7 972-0BB51-0XA0

6ES7 193-1BH00-0XA0 6ES7 193-1BL00-0XA0 6ES7 901-4BD00-0XA0

6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 195-1GG30-0XA0 6ES7 195-1GC00-0XA0 6ES7 195-7HC00-0XA0

5/236

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 326 F digital input module Safety Integrated

Ordering data
SITOP power supply module for ET 200M; 120/230 V AC, 24 V DC, 5 A; Type PS 307-1E Front connectors 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Labeling strips For fail-safe modules (spare part); 10 units Label cover For fail-safe modules (spare part); 10 units LK 393 cable guide For F modules; L+ and M connections; 5 units

Order No. 6ES7 307-1EA00-0AA0 S7-300 manual Design, CPU data, module data, instruction list German English 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 French Spanish Italian SIMATIC Manual Collection 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 392-2XX20-0AA0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (Programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year 6ES7 393-4AA10-0AA0 Current S7 Manual Collection DVD and the three subsequent updates

Order No.

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0 6ES7 998-8XC01-8YE0

6ES7 392-2XY20-0AA0

6ES7 998-8XC01-8YE2

Siemens IK PI 2009

5/237

Siemens AG 2008

ET 200M F Digital/Analog Modules


SIPLUS SM 326 F digital input module Safety Integrated

SIMATIC ET 200 distributed I/Os

Overview

Ordering data
F digital input module SIPLUS SM 326 24 inputs, 24 V DC Accessories

Order No. 6AG1 326-1BK01-2AB0

see F digital input module ordering data

Digital inputs for the fail-safe SIMATIC S7 systems They are suitable for connecting: - switches and 2-wire proximity switches (BEROs) - Sensors according to NAMUR and mechanical contacts, also for signals from hazardous areas With integral safety functions for fail-safe operation Can be used in fail-safe mode - Centrally: With S7-31xF-2 DP - Distributed in ET 200M: With SIMATIC IM 151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH Can be used in standard mode as an S7-300 module
Fail-safe digital input module SIPLUS SM 326 Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 326-1BK01-2AB0 6ES7 326-1BK01-0AB0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) The technical data are identical with those of the based-on modules.

Technical specifications

5/238

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 326 F digital output module Safety Integrated

Overview
Digital outputs for the fail-safe SIMATIC S7 systems Two variants (1 x source/source output, 1 x source/sink output) For connection of solenoid valves, DC contactors and signaling lamps With integral safety functions for fail-safe operation Can be used in fail-safe mode - Centrally: With S7-31xF-2 DP - Distributed in ET 200M: With SIMATIC IM 151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH Can be used in standard mode as an S7-300 module (only applies to 6ES7326-2BF01-0AB0)

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage1L+, max. from load voltage 2L+ (without load), max. from load voltage 3L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital outputs Number of digital outputs cable length, shielded, max. 10 1,000 m; 200 m for SIL3, AK 6, Cat 4 600 m L+ (-53 V) without series diode, L+ (-33 V) with series diode 5W L+ (-1.8 V) L+ (-1 V) L+ (-1 V) 8 30 m 40-pin 40-pin 70 mA; from supply voltage 100 mA 100 mA 100 mA 12 W 75 mA; from supply voltage 100 mA 100 mA 100 mA 12 W for signal "1" permissible range for 40 to 60 C, min. for signal "1" permissible range for 40 to 60 C, max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. 5 A; without series diode, 4 A with series diode 7.5 A; without series diode, 5 A with series diode 5 A; without series diode, 4 A with series diode 5A 10 Hz 2 Hz 10 Hz 30 Hz 2 Hz 10 Hz 24 V; 1L+, 2L+, 3L+ 24 V; 1L+, 2L+, 3L+ 6ES7 3262BF01-0AB0 6ES7 3262BF40-0AB0 Order No. Output current for signal "1" rated value for signal "1" permissible range for 0 to 40 C, min. for signal "1" permissible range for 0 to 40 C, max. 2A 7 mA 2 A; 2 A for horizontal installation, 1 A for vertical installation 7 mA 2A 7 mA 2 A; 2 A for horizontal installation, 1 A for vertical installation 7 mA 6ES7 3262BF01-0AB0 6ES7 3262BF40-0AB0

1 A; for horizon- 1 A; for horizontal installation tal installation 0.5 mA

for signal "0" residual current, max. 0.5 mA

Cable length unshielded, max. Limitation of inductive shutdown voltage to

50 m Yes; Electronic L+ (-33 V)

Short-circuit protection of the output Yes; Electronic

horizontal installation - up to 40 C, max. 5W - up to 60 C, max.

7.5 A

Lamp load, max. Output voltage for signal "1" with series diode, min. for signal "1" without series diode, min.

5A

Siemens IK PI 2009

5/239

Siemens AG 2008

ET 200M F Digital/Analog Modules


Technical specifications (continued)
Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostic information readable Isolation Isolation checked with Isolation Isolation, digital outputs between the channels between the channels, in groups of Yes 5 Yes Yes Yes 4 Yes Yes 500 V DC / 350 V AC Yes Yes Yes 6ES7 3262BF01-0AB0

SIMATIC ET 200 distributed I/Os

SM 326 F digital output module Safety Integrated

6ES7 3262BF40-0AB0

Order No. Standards, approvals, certificates Highest safety class achievable in safety mode

6ES7 3262BF01-0AB0

6ES7 3262BF40-0AB0

Yes; Parameterizable

to DIN VDE 0801 to EN 954 to IEC 61508 Dimensions Dimensions Width Height Depth Weights Weight, approx.

AK 5 and 6 Cat. 4 SIL 3 Cat. 4 SIL 3

500 V DC / 350 V AC

80 mm 125 mm 120 mm 465 g

80 mm 125 mm 120 mm 465 g

between the channels and the backplane bus between the channels and the voltage supply to the electronics

Ordering data
F digital output module SM 326 10 outputs, 24 V DC, 2 A 8 outputs, 24 V DC, 2 A Distributed Safety V5.4 programming tool Task: Software for configuring fail-safe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating license Software Update Service Distributed Safety Upgrade From V5.x to V5.4; Floating license for 1 user Labeling sheet with strips for 10 electronic blocks For 16-channel electronic blocks incl. add-on terminals For 32-channel electronic blocks incl. add-on terminals Connecting cable for PROFIBUS 12 Mbit/s, for connecting PG to PROFIBUS DP, pre-assembled with 2 x 9-pin Sub-D connector, 3m

Order No. PROFIBUS bus connector 6ES7 326-2BF01-0AB0 6ES7 326-2BF40-0AB0 90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, with PG socket, up to 12 Mbit/s DIN rail for active bus modules 6ES7 193-1BH00-0XA0 6ES7 193-1BL00-0XA0 6ES7 901-4BD00-0XA0 for max. 5 active bus modules, for function "Insertion and removal" 483 mm (19") long 530 mm long 620 mm long 2000 mm long

Order No.

6ES7 972-0BA12-0XA0

6ES7 972-0BB12-0XA0

6ES7 972-0BA51-0XA0

6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5

6ES7 972-0BB51-0XA0

6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 195-1GG30-0XA0 6ES7 195-1GC00-0XA0

5/240

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 326 F digital output module Safety Integrated

Ordering data
Active bus module BM 1 x 80 for 1 module with 80 mm width SITOP power supply module for ET 200M; 120/230 V AC, 24 V DC, 5 A; Type PS 307-1E Front connectors 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Labeling strips For fail-safe modules (spare part), 10 units Label cover For fail-safe modules (spare part), 10 units LK 393 cable guide For F modules; L+ and M connections, 5 units

Order No. 6ES7 195-7HC00-0XA0 S7-300 manual Design, CPU data, module data, instruction list 6ES7 307-1EA00-0AA0 German English French Spanish Italian 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (Programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year 6ES7 392-2XY20-0AA0 Current S7 Manual Collection DVD and the three subsequent updates

Order No.

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0 6ES7 998-8XC01-8YE0

6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 392-2XX20-0AA0

6ES7 998-8XC01-8YE2

6ES7 393-4AA10-0AA0

Siemens IK PI 2009

5/241

Siemens AG 2008

ET 200M F Digital/Analog Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 326 F digital output Safety Integrated

Digital outputs for the fail-safe SIMATIC S7 systems Two variants (1 x source/current sourcing, 1 x source/current sinking) For connection of solenoid valves, DC contactors and indicator lights With integral safety functions for fail-safe operation Can be used in fail-safe mode - Centrally: With S7-31xF-2 DP - Distributed in ET 200M: With SIMATIC IM 151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH Can be used in standard mode as an S7-300 module (only applies to 6ES7326-2BF01-0AB0)

Fail-safe digital output module SIPLUS SM 326 Order No. 6AG1 326-2BF01-2AB0 6ES7 326-2BF01-0AB0 6AG1 326-2BF40-2AB0 6ES7 326-2BF40-0AB0 6AG1 326-2BF40-2AY0 6ES7 326-2BF40-0AB0

Order No. based on Ambient temperature range Environmental conditions Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical data

-25 ... +60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes No Yes

The technical data are identical with those of the based-on modules. Order No.

Ordering data
F digital output module SIPLUS SM 326 10 outputs, 24 V DC, 2 A 8 outputs, 24 V DC, 2 A 8 outputs, 24 V DC, 2 A

6AG1 326-2BF01-2AB0 6AG1 326-2BF40-2AB0 6AG1 326-2BF40-2AY0

5/242

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 336 F analog input module Safety Integrated

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from backplane bus DC 5 V, max. from supply voltage L+, max. Power loss, typ. Connection point required front connectors Analog inputs Number of analog inputs Number of analog inputs for voltage measurement 6 4 200 m 40-pin 90 mA 160 mA; typically 4.25 W 24 V Yes 6ES7 336-4GE00-0AB0

Analog inputs for the fail-safe SIMATIC S7 systems Applicable in the ET 200M distributed I/O device with IM 153-2 HF as well as centrally with SIMATIC S7-31xF-2 DP Properties of the SM 336; F-AI 6 x 0/4 - 20 mA HART: - 6 analog inputs with galvanic isolation between channels and backplane bus - Input ranges: 0 to 20 mA, 4 to 20 mA - Short-circuit proof power supply from 2 or 4-wire transducer via the module - External encoder supply possible - Applicable in safety mode - HART communication - Firmware update using HW Config - Identification data

cable length, shielded, max.

permissible input frequency for volt- 30 V age input (destruction limit), max. permissible input current for current input (destruction limit), max. Input ranges (rated values), voltages 0 to +10 V Input ranges (rated values), currents 0 to 20 mA 4 to 20 mA Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, ms Interference voltage suppression for interference frequency f1 in Hz 14 Bit 20 ms (at 50 Hz); 16.66 ms (at 60 Hz) 38 dB Yes Yes Yes 40 mA

Siemens IK PI 2009

5/243

Siemens AG 2008

ET 200M F Digital/Analog Modules


Technical specifications (continued)
Order No. Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer Errors/accuracies Operational limit in overall temperature range Voltage, relative to input area Current, relative to input area Basic error limit (operational limit at 25 C) Voltage, relative to input area Current, relative to input area Status information/ alarms/diagnostics +/- 0,4 % +/- 0,4 % +/- 0,48 % +/- 0,48 % Yes Yes 6ES7 336-4GE00-0AB0

SIMATIC ET 200 distributed I/Os

SM 336 F analog input module Safety Integrated

Order No. Isolation Isolation, analog inputs between the channels between the channels and the backplane bus between the channels and the voltage supply to the electronics Standards, approvals, certificates Highest safety class achievable in safety mode to DIN V 19250 to EN 954 to IEC 61508 Dimensions Dimensions Width Height Depth Weights Weight, approx.

6ES7 336-4GE00-0AB0

No Yes Yes; only if sensors are externally supplied

AK 6 Cat. 4 SIL 3

80 mm 125 mm 120 mm 480 g

Alarms Diagnostic alarm Diagnoses Diagnostic information readable Isolation Isolation checked with 500 V DC / 350 V AC Yes Yes; Parameterizable

5/244

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules

SM 336 F analog input module Safety Integrated

Ordering data
F analog input module SM 336 6 inputs, 15 bit, 0/4 - 20 mA HART Distributed Safety V5.4 programming tool Task: Software for configuring fail-safe user programs for SIMATIC S7-300F, S7-400F, ET 200S Requirement: STEP 7 V5.3 SP3 and higher Floating License Software Update Service Distributed Safety Upgrade From V5.x to V5.4; Floating License for 1 user Labeling sheet with strips for 10 electronic blocks For 16-channel electronic blocks incl. add-on terminals For 32-channel electronic blocks incl. add-on terminals Connecting cable for PROFIBUS 12 Mbit/s, for connecting PG to PROFIBUS DP, pre-assembled with 2 x 9-pin Sub-D connector, 3m PROFIBUS bus connector 90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, without PG socket, up to 12 Mbit/s 90 cable outlet, terminating resistor with isolating function, insulation displacement technology, Fast Connect, with PG socket, up to 12 Mbit/s DIN rail for active bus modules for max. 5 active bus modules for hot swapping function Length: 483 mm Length: 530 mm Length: 620 mm Length: 2000 mm Active bus module BM 1 x 80 for 1 module with 80 mm width SITOP power supply module for ET 200M; 120/230 V AC, 24 V DC, 5 A; Type PS 307-1E

Order No. 6ES7 336-4GE00-0AB0 Front connectors 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 6ES7 833-1FC02-0YA5 6ES7 833-1FC00-0YX2 6ES7 833-1FC02-0YE5 40-pin, with FastConnect 1 unit Labeling strips For fail-safe modules (spare part), 10 units Label cover 6ES7 193-1BH00-0XA0 6ES7 193-1BL00-0XA0 6ES7 901-4BD00-0XA0 For fail-safe modules (spare part), 10 units S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single License Upgrade Single License Labeling sheets for machine inscription For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige 6ES7 972-0BB12-0XA0 yellow red LK 393 cable guide 6ES7 972-0BA51-0XA0 For F modules; L+ and M connections, 5 units S7-300 manual 6ES7 972-0BB51-0XA0 Design, CPU data, module data, instruction list German English French Spanish Italian 6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 195-1GG30-0XA0 6ES7 195-1GC00-0XA0 6ES7 195-7HC00-0XA0 SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (distributed I/O), SIMATIC PC, SIMATIC PG (programming devices), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates

Order No.

6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0

6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 392-2XX20-0AA0

6ES7 392-2XY20-0AA0

5
2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 972-0BA12-0XA0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0 6ES7 393-4AA10-0AA0

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0 6ES7 998-8XC01-8YE0

6ES7 307-1EA00-0AA0

6ES7 998-8XC01-8YE2

Siemens IK PI 2009

5/245

Siemens AG 2008

ET 200M F Digital/Analog Modules


Isolation module

SIMATIC ET 200 distributed I/Os

Overview
Supports mixed operation of fail-safe signal modules in safety mode and S7-300 standard modules in an ET 200M when Cat. 4 or SIL 3 has to be achieved The isolation module is not required if the safety class or safety category to be achieved is less than SIL 3 or Cat. 4, respectively When Cat. 4/SIL 3 is required, the isolation module must be implemented in the following situations:
Application Central use after CPU 31xF-2 DP or CPU 31xF-2 PN/DP Only fail-safe modules in the tier Standard and fail-safe modules in the tier Central use after CPU 31xF-2 DP or CPU 31xF-2 PN/DP in an expansion rack Only fail-safe modules in the tier Standard and fail-safe modules in the tier Distributed behind the IM 153-2 with copper connection Only fail-safe modules in the station Standard and fail-safe modules in the station Distributed behind the IM 153-2 with fiber-optic connection Only fail-safe modules in the station Standard and fail-safe modules in the station No Yes, after the last standard module and before the first fail-safe module Yes, after the IM 153-2 Yes, after the last standard module and before the first fail-safe module Yes, after the IM 36x Yes, after the last standard module and before the first fail-safe module Yes, behind the CPU Yes, after the last standard module and before the first fail-safe module Isolation module must be used

Technical specifications
Order No. Weights Weight, approx. 10 g Order No. 6ES7 195-7KF00-0XA0 6ES7 195-7KF00-0XA0

Ordering data
Isolation module for simultaneous operation of fail-safe and standard modules in an ET 200M Isolation bus module for accommodating the isolating module in an ET 200M

6ES7 195-7HG00-0XA0

5/246

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M F Digital/Analog Modules


SIPLUS isolating module (extended temperature range)

Overview

Ordering data
Isolating module for simultaneous operation of fail-safe and standard modules in an ET 200M Isolating bus module for accommodating the isolating module in an ET 200M Accessories

Order No. 6AG1 195-7KF00-2XA0

6ES7 195-7HG00-0XA0

see F digital input module ordering data

Permits combined operation of fail-safe signal modules in safety mode and standard S7-300 modules in the same ET 200M system. The isolation module is not required if safety class SIL 3 or safety class < Cat. 4 is to be achieved.
SIPLUS S7-300 isolation module Order No. Order No. based on Ambient temperature range Environmental conditions 6AG1 195-7KF00-2XA0 6ES7 195-7KF00-0XA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere). Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical data

The technical data are identical with those of the based-on modules.

Siemens IK PI 2009

5/247

Siemens AG 2008

ET 200M Digital Modules


SM 321 digital input module

SIMATIC ET 200 distributed I/Os

Overview
Digital inputs For connecting standard switches and two-wire proximity switches (BERO)

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors

6ES7 3211BH02-0AA0

6ES7 3211BH50-0AA0

6ES7 3211BL00-0AA0

6ES7 3211BP00-0AA0

6ES7 3211BH10-0AA0

24 V 25 mA 10 mA 3.5 W 20-pin

24 V

24 V

24 V

24 V

10 mA 3.5 W 20-pin

15 mA 6.5 W 40-pin

100 mA 7W Cable: 6ES7 3924Bxx0-0AA0 terminal blocks: 6ES7 3921xN00-0AA0

110 mA 3.8 W 20-pin

Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 60 C, max. Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" 24 V -30 to +5 V 13 to 30 V 24 V -5 to +30 V -13 to -30 V 24 V -30 to +5 V 13 to 30 V 24 V -30...5 13...30 24 V -30 to +5 V 13 to 30 V 1,000 m 600 m Yes 1,000 m 600 m Yes 1,000 m 600 m Yes Yes 1,000 m 600 m Yes 16 16 32 32 16 32 64 32 16 16 16 32 64 16 No No No Yes

16

16

16

5/248

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 321 digital input module

Technical specifications (continued)


Order No. Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Voltages and currents Load voltage L+ Rated value (DC) Load voltage L1 Rated value (AC) 24 V 230 V; 120/230 V AC; all load voltages must have the same phase. 24 V 24 V 48 V 200 g 200 g 260 g 6ES7 321-1CH00-0AA0 230 g; approx. 6ES7 321-1CH20-0AA0 200 g 6ES7 321-1FH00-0AA0 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 112 mm 40 mm 125 mm 120 mm 16 Yes; Optocoupler 16 Yes; Optocoupler Yes 16 Yes; Optocoupler 16 Yes 16 Yes; Optocoupler 500 VDC 500 VDC 500 VDC 500 VDC 500 VDC Yes Yes Yes Yes Yes No No No No No No No No Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA Yes 1.5 mA 1.2 ms 4.8 ms 1.2 ms 4.8 ms 1.2 ms 4.8 ms 1.2 ms 4.8 ms 25 s 75 s 7 mA 7 mA 7 mA 4.2 mA; typical 7 mA 6ES7 3211BH02-0AA0 6ES7 3211BH50-0AA0 6ES7 3211BL00-0AA0 6ES7 3211BP00-0AA0 6ES7 3211BH10-0AA0

6ES7 321-7BH01-0AB0

Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors 20-pin 40-pin 20-pin 20-pin 90 mA 130 mA 4W 100 mA 1.5 W at 24 V; 2,8 W at 48 V 40 mA 4.3 W 29 mA 4.9 W

Siemens IK PI 2009

5/249

Siemens AG 2008

ET 200M Digital Modules


SM 321 digital input module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs vertical installation - up to 40 C, max. horizontal installation - up to 50 C, max. - up to 60 C, max. Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 1,000 m 600 m 1,000 m 600 m Yes Yes 1,000 m 600 m Yes 1,000 m 600 m Yes 16 16 8 8 8; 6 to Ue 146 V 16 16 16 16 16 Yes No No No 6ES7 321-7BH01-0AB0 6ES7 321-1CH00-0AA0 6ES7 321-1CH20-0AA0 6ES7 321-1FH00-0AA0

16

16

16

Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, AC Rated value, DC for signal "0" for signal "1" Frequency range Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - programmable - at " to "1", min. - at "0" to "1", max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Alarms Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with

24 V; AC 24 or 48 V 24 V -30 to +5 V 13 to 30 V 24 V; DC 24 or 48 V -5 to +5 V AC 14 to 60 V AC 0 to 63 Hz 7 mA 2.7 mA 3.5 mA 48 V; DC 48 to 125 V -146 to +15 V DC 30 to 146 V DC

230 V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz 6.5 mA; (120V, 60Hz), 16 mA (230V, 50Hz)

Yes; 0.1 / 0.5 / 3 / 15 / 20 ms

No 0.1 ms 3.5 ms

No

16 ms

25 ms

Yes 2 mA

Yes 1 mA

Yes 1 mA

Yes 2 mA

Yes Yes; Parameterizable Yes; parameterizable Yes; parameterizable Yes

No No No No Yes

No No No No Yes

No No No No Yes

500 VDC

1500 V DC

4000 VDC

5/250

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 321 digital input module

Technical specifications (continued)


Order No. Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Voltages and currents Load voltage L1 Rated value (AC) Current consumption from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 60 C, max. Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, AC for signal "0" for signal "1" Frequency range Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - programmable - at "0" to "1", max. No 15 ms No 25 ms No 25 ms Siemens IK PI 2009 21 mA 6.5 mA; (120 V); 11mA (230 V) 7.5 mA; (120 V); 17.3 mA (230 V) 120 V 0 to 20 V 74 to 132 V 47 to 63 Hz 230 V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz 120 V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz Yes 1,000 m 600 m 1,000 m 600 m Yes 1,000 m 600 m Yes 32 32 24 8 8 32 8 8 No No No 40-pin 20-pin 40-pin 16 mA 4W 29 mA 4.9 W 100 mA 4.9 W 120 V 230 V; 120/230 V AC 230 V; 120/230 V AC; all load voltages must have the same phase. 200 g 6ES7 321-1EL00-0AA0 260 g 200 g 6ES7 321-1FF01-0AA0 240 g 6ES7 321-1FF10-0AA0 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 16 Yes; Optocoupler Yes 1 Yes; Optocoupler Yes 8 Yes; Optocoupler Yes 4 Yes; Optocoupler 6ES7 321-7BH01-0AB0 6ES7 321-1CH00-0AA0 6ES7 321-1CH20-0AA0 6ES7 321-1FH00-0AA0

5/251

Siemens AG 2008

ET 200M Digital Modules


SM 321 digital input module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Alarms Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Yes Yes Yes No No No No No No No No No No No No Yes 4 mA Yes 2 mA Yes 2 mA 6ES7 321-1EL00-0AA0 6ES7 321-1FF01-0AA0 6ES7 321-1FF10-0AA0

Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 300 g 240 g 240 g 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm Yes 8 Yes; Optocoupler Yes 2 Yes; Optocoupler Yes 1 Yes; Optocoupler 2500 V DC 4000 VDC 1500 VAC

5/252

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 321 digital input module

Ordering data
SM 321 Digital Input Modules incl. labeling strips, bus connector 16 inputs, 24 V DC 16 inputs, 24 V DC, active low 32 inputs, 24 V DC 64 inputs, 24 V DC, active high/low Note: 6ES7392-4...0-0AA0 connection cable and 6ES7392-1.N00-0AA0 terminal blocks necessary. 16 inputs, 24 48 V DC 16 inputs, 48 125 V DC 16 inputs, 24 V DC, for isochronous mode 32 inputs, 120 V AC 8 inputs, 120/230 V AC 8 inputs, 120/230 V AC, single root 16 inputs, 120/230 V AC 16 inputs, 24 V DC, for isochronous mode, diagnostics-capable Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit S7-300 connecting cable For 64-channel modules; 2 units 1m 2.5 m 5m Terminal block For 64-channel modules; 2 units With screw contacts With spring-loaded contacts Front door, elevated design e.g. for 32-channel modules; for connecting 1.3mm2/ 16 AWG cables

Order No. SIMATIC TOP connect Bus connectors 1 unit (spare part) 6ES7 321-1BH02-0AA0 6ES7 321-1BH50-0AA0 6ES7 321-1BL00-0AA0 6ES7 321-1BP00-0AA0 Labeling strips 10 units (spare part) for modules with 20-pin front connector for modules with 40-pin front connector Label cover 10 units (spare part) 6ES7 321-1CH00-0AA0 6ES7 321-1CH20-0AA0 6ES7 321-1BH10-0AA0 6ES7 321-1EL00-0AA0 6ES7 321-1FF01-0AA0 6ES7 321-1FF10-0AA0 6ES7 321-1FH00-0AA0 6ES7 321-7BH01-0AB0 for modules with 20-pin front connector for modules with 40-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 petrol light-beige yellow 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 red For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red SIMATIC Manual Collection 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates S7-300 manual 6ES7 392-1AN00-0AA0 6ES7 392-1BN00-0AA0 6ES7 328-0AA00-7AA0 Design, CPU data, module data, instruction list German English French Spanish Italian

Order No. See Catalog ST 70 6ES7 390-0AA00-0AA0

6ES7 392-2XX00-0AA0 6ES7 392-2XX10-0AA0

6ES7 392-2XY00-0AA0 6ES7 392-2XY10-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-4BB00-0AA0 6ES7 392-4BC50-0AA0 6ES7 392-4BF00-0AA0

6ES7 998-8XC01-8YE2

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0 Siemens IK PI 2009

5/253

Siemens AG 2008

ET 200M Digital Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 321 digital input module (extended temperature range)

Digital inputs For connection of switches and 2-wire proximity switches (BEROs)

SIPLUS SM 321

16 DI 6AG1 3211BH02-2AA0 6ES7 3211BH02-0AA0

32 DO 6AG1 3211BL00-2AA0 6ES7 3211BL00-0AA0

SIPLUS SM 321 Order No. Order No. based on Ambient temperature range Environmental conditions

16 DI 48 to 125 VDC 6AG1 321-1CH20-2AA0 6ES7 321-1CH20-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Order No. Order No. based on Ambient temperature range Environmental conditions

- 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules. 16 DI 6AG1 321-7BH01-2AB0 6ES7 321-7BH01-0AB0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes SIPLUS SM 321 Order No. Order No. based on Ambient temperature range Environmental conditions

The technical data are identical with those of the based-on modules.

SIPLUS SM 321 Order No. Order No. based on Ambient temperature range Environmental conditions

8 DI 120/230 VAC 6AG1 321-1FF01-2AA0 6ES7 321-1FF01-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules. Order No.

The technical data are identical with those of the based-on modules. Order No.

Ordering data
SIPLUS SM 321 Digital Input Modules incl. labeling strips, bus connector 16 inputs, 24 V DC 32 inputs, 24 V DC 16 inputs, 48 125 V DC 8 inputs, 120/230 V AC 16 inputs, 24 V DC, for isochronous mode, diagnostics-capable

Accessories

see Digital input module ordering data

6AG1 321-1BH02-2AA0 6AG1 321-1BL00-2AA0 6AG1 321-1CH20-2AA0 6AG1 321-1FF01-2AA0 6AG1 321-7BH01-2AB0

5/254

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 322 digital output module

Overview
Digital outputs For connecting solenoid valves, contactors, low-power motors, lamps and motor starters

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors 20-pin 20-pin 40-pin Cable: 6ES7 3924Bxx0-0AA0 terminal blocks: 6ES7 3921xN00-0AA0 64 64 20-pin 80 mA 80 mA 4.9 W 110 mA 70 mA 5W 160 mA 110 mA 6.6 W 75 mA 100 mA 6W 75 mA 100 mA 6W 90 mA 70 mA 5W 24 V 24 V 24 V 24 V 24 V 24 V 6ES7 3221BH01-0AA0 6ES7 3221BH10-0AA0 6ES7 3221BL00-0AA0 6ES7 3221BP00-0AA0 6ES7 3221BP50-0AA0 6ES7 3228BF00-0AB0

Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Limitation of inductive shutdown voltage to Lamp load, max. Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range, min. for signal "1" permissible range, max. for signal "1" permissible range for 0 to 40 C, min. for signal "1" permissible range for 0 to 40 C, max. for signal "1" permissible range for 40 to 60 C, min. for signal "1" permissible range for 40 to 60 C, max. for signal "1" minimum load current for signal "0" residual current, max. 5 mA 0.6 A 5 mA 0.6 A 5 mA 0.5 mA 5 mA 0.6 A 5 mA 0.6 A 5 mA 0.5 mA 5 mA 0.6 A 5 mA 0.6 A 5 mA 0.5 mA 0.1 mA 0.5 A 0.5 A 0.5 A 0.3 A 2.4 mA 0.36 A 0.3 A 2.4 mA 0.36 A 10 mA 0.6 A 10 mA 0.6 A 10 mA 0.5 mA Siemens IK PI 2009 0.5 A L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.5V) M+ (0.5 V) L+ (-0.8 to -1.6 V) 16 1,000 m 600 m L+ (-53 V) 5W 16 1,000 m 600 m Yes; Electronic L+ (-53 V) 5W 32 1,000 m 600 m Yes; Electronic L+ (-53 V) 5W 5W Yes Yes M+ (45 V) 5W 8 1,000 m 600 m Yes; Electronic L+ (-45 V) 5W

Short-circuit protection of the output Yes; Electronic

5/255

Siemens AG 2008

ET 200M Digital Modules


SM 322 digital output module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 60 C, max. Status information/ alarms/diagnostics Alarms Diagnostic alarm No No No Yes; channel by channel No No Yes 500 VDC 2A 4A 3A 2A 4A 3A 2A 4A 3A 1.6 A 1.2 A 1.6 A 1.6 A 1.2 A 4A 4A 3A 100 Hz 0.5 Hz 10 Hz 1,000 Hz 0.5 Hz 10 Hz 10 Hz 100 Hz 100 Hz 0.5 Hz 10 Hz 100 Hz 0.5 Hz 10 Hz 100 Hz 2 Hz 10 Hz 6ES7 3221BH01-0AA0 6ES7 3221BH10-0AA0 6ES7 3221BL00-0AA0 6ES7 3221BP00-0AA0 6ES7 3221BP50-0AA0 6ES7 3228BF00-0AB0

Diagnoses Diagnostics Isolation Isolation checked with Isolation Isolation, digital outputs between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. Order No. Voltages and currents Load voltage L+ Rated value (DC) Load voltage L1 Rated value (AC) Current consumption from load voltage L+ (without load), max. from load voltage L1 (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors 40-pin 20-pin 20-pin 20-pin 40-pin 20-pin 100 mA 2.8 W 100 mA 7.2 W 40 mA 6.8 W 200 mA 2 mA 60 mA 2 mA 100 mA 8.6 W 2 mA 100 mA 8.6 W 2 mA 3 mA 200 mA 8.6 W 230 V; 120/230 V AC 230 V; 120/230 V AC 230 V; 120/230 V AC 24 V; 24 / 48 48 V; 48 to 125 V DC 24 V 190 g 6ES7 3225GH00-0AB0 200 g 6ES7 3221CF00-0AA0 260 g 6ES7 3221BF01-0AA0 6ES7 3221FF01-0AA0 6ES7 3225FF00-0AB0 210 g 6ES7 3221FH00-0AA0 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 112 mm 40 mm 125 mm 112 mm 40 mm 125 mm 120 mm 8 Yes; Optocoupler 8 Yes; Optocoupler 8 Yes; Optocoupler 16 Yes; Optocoupler 16 Yes; Optocoupler 8 Yes; Optocoupler 500 VDC 500 VDC 500 VDC No No No

5/256

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 322 digital output module

Technical specifications (continued)


Order No. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Short-circuit protection of the output 16 1,000 m 600 m No; to be provided externally 8 1,000 m 600 m Yes; Electronic 8 1,000 m 600 m Yes; Electronic 8 1,000 m 600 m Yes; Fuse 8 A, 250 V; per group 8 1,000 m 600 m Yes; to be provided externally; fuse 3,15 A / 250 V, quick response 16 1,000 m 600 m Yes; Fuse 8 A, 250 V; per group 6ES7 3225GH00-0AB0 6ES7 3221CF00-0AA0 6ES7 3221BF01-0AA0 6ES7 3221FF01-0AA0 6ES7 3225FF00-0AB0 6ES7 3221FH00-0AA0

Limitation of inductive shutdown voltage to Lamp load, max. 2.5 W

M (-1 V) 15 W; 15 W (48 V) or 40 W (125 V)

L+ (-48 V) 10 W 50 W 50 W 50 W

Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 40 C, min. for signal "1" permissible range for 0 to 40 C, max. for signal "1" permissible range for 40 to 60 C, min. for signal "1" permissible range for 40 to 60 C, max. for signal "1" minimum load current for signal "1" permissible peak current, max. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 50 C, max. - up to 60 C, max. all other mounting positions - up to 40 C, max. Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostics Yes; Parameters can be assigned No No Yes Yes; Off / last value / substitute value Yes Yes; Parameterizable No No No Yes; Parameterizable No 4A 6A 4A 3A 4A 2A 4A 4A 2A 4A 8A 4A 2A 4A 2A 0.5 Hz 10 Hz 25 Hz 0.5 Hz 10 Hz 100 Hz 0.5 Hz 10 Hz 10 Hz 0.5 Hz 1 Hz 10 Hz 0.5 Hz 1 Hz 10 Hz 0.5 Hz 1 Hz 1.5 A; for 50 ms, 1 A 2 s one-time 0.5 A 1.5 A 10 mA 1.5 A 10 mA 1.5 A 10 mA 3 A; for 10 ms 0.5 mA 0.5 mA 2A 5 mA 2.4 A 5 mA 2.4 A 5 mA 2A 10 mA 2A 10 mA 1A 10 mA 20 A; max. 1 AC cycle 2 mA 2A 10 mA 2A 10 mA 1A 10 mA 1A 10 mA 1A 10 mA 0.5 A 10 mA L+ (-0.25 V) L+ (-0.8 V) L1 (-1.5 V) L1 (-8.5 V)

20 A; 20 A; with 2 half waves with 2 half waves 2 mA 2 mA

for signal "0" residual current, max. 10 A

0.5 A; (8 A per module) 0.5 A; (8 A per module)

Siemens IK PI 2009

5/257

Siemens AG 2008

ET 200M Digital Modules


SM 322 digital output module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Isolation Isolation checked with Isolation Isolation, digital outputs between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 260 g 6ES7 3221FL00-0AA0 250 g 6ES7 3221HF01-0AA0 190 g 275 g 6ES7 3221HF10-0AA0 275 g 6ES7 3225HF00-0AB0 275 g 6ES7 3221HH01-0AA0 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 1 Yes; Optocoupler 4 Yes; Optocoupler 4 Yes; Optocoupler 4 Yes; Optocoupler 1 Yes; Optocoupler 8 Yes; Optocoupler 1500 VAC 1500 VAC 500 VDC 1500 VAC 1500 VAC 4000 VDC 6ES7 3225GH00-0AB0 6ES7 3221CF00-0AA0 6ES7 3221BF01-0AA0 6ES7 3221FF01-0AA0 6ES7 3225FF00-0AB0 6ES7 3221FH00-0AA0

Order No. Voltages and currents Load voltage L+ Rated value (DC) Load voltage L1 Rated value (AC) Current consumption from load voltage L+ (without load), max. from load voltage L1 (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max.

24 V 120 V; 120/230 V AC 110 mA; Current consumption of relay 10 mA 190 mA 25 W 20-pin 32 1,000 m 600 m 110 mA 40 mA 3.2 W 20-pin 8; Relay 1,000 m 600 m

120 V 230 V

24 V 230 V

120 V 230 V

40 mA 4.2 W 40-pin 8; Relay 1,000 m 600 m No; to be provided externally

100 mA 3.5 W 40-pin 8; Relay 1,000 m 600 m No; to be provided externally 1,500 W; AC 230 V

100 mA 4.5 W 20-pin 16; Relay 1,000 m 600 m

Short-circuit protection of the output No Lamp load, max. Output current for signal "1" rated value for signal "1" permissible range for 0 to 40 C, min. for signal "1" permissible range for 0 to 40 C, max. for signal "1" permissible range for 40 to 60 C, min. for signal "1" permissible range for 40 to 60 C, max. for signal "1" minimum load current for signal "1" permissible peak current, max. 1A 10 mA 1A 10 mA 1A 10 mA 10 A; per group (for 2 AC cycles) 5 mA 50 W 50 W

1,500 W; AC 230 V

50 W; AC 230 V

5 mA

10 mA

10 mA

for signal "0" residual current, max. 2 mA

5/258

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 322 digital output module

Technical specifications (continued)


Order No. Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. mechanical, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 60 C, max. Relay outputs Rated input voltage of relay L+ (DC) Number of operating cycles 24 V; 110 mA 300,000; 230 V AC: 100000; 120 V AC: 200000; 24 V DC: 300000 (at 2 A) 24 V 300,000; 300000 (24 V DC, at 2 A); 200000 (120 V AC, at 3 A); 100000 (230 V AC, at 3 A) 3 A; 3 A (230 V DC); 2 A (24 V AC) 8 A; 8 A (230 V DC); 5 A (24 V AC) 100,000; 100,000 (DC 24 V, at 5 A), 100,000 (AC 230 V, at 5 A) 24 V 100,000; 50000 (24 V DC, at 2 A); 700000 (120 V AC, at 2 A); 100000 (230 V AC, at 2 A) 2 A; 2 A (230 V AC), 2 A (24 V DC) 2 A; 2 A (230 V AC), 2 A (24 V DC) 4A 4A 3A 5A 5A 8A 10 Hz 0.5 Hz 1 Hz 2 Hz 0.5 Hz 2 Hz 10 Hz 2 Hz 0.5 Hz 2 Hz 10 Hz 2 Hz 0.5 Hz 2 Hz 10 Hz 1 Hz 0.5 Hz 1 Hz 10 Hz 6ES7 3221FL00-0AA0 6ES7 3221HF01-0AA0 6ES7 3221HF10-0AA0 6ES7 3225HF00-0AB0 6ES7 3221HH01-0AA0

5A

5A

8A

Switching capacity of the contacts with inductive load, max. with resistive load, max. Status information/ alarms/diagnostics Alarms Diagnostic alarm Diagnoses Diagnostics Isolation Isolation checked with Isolation Isolation, digital outputs between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 500 g 190 g 320 g 320 g 250 g 80 mm 125 mm 117 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 8 Yes; Optocoupler 2 Yes; Optocoupler 1 Yes; Optocoupler 1 Yes; Optocoupler 8 Yes; Optocoupler 4000 VDC 1500 VAC 2000 V AC 1500 VAC 1500 VAC Yes No No Yes; Off / last value / substitute value No No No No Yes; Parameterizable No 2 A; 2 A (230 V AC), 2 A (24 V DC) 2A 5 A; 5 A (230 V DC); 5 A (24 V AC) 5 A; 5 A (230 V AC), 5 A (24 V DC)

Siemens IK PI 2009

5/259

Siemens AG 2008

ET 200M Digital Modules


SM 322 digital output module

SIMATIC ET 200 distributed I/Os

Ordering data
SM 322 digital output modules incl. labeling strips, bus connector 8 outputs, 24 V DC, 2 A 16 outputs, 24 V DC, 0.5 A 16 outputs, 24 V DC, 0.5 A, high speed 32 outputs, 24 V DC, 0.5 A 64 outputs, 24 V DC, 0.3 A Note: 6ES7392-4...0-0AA0 connection cable and 6ES7392-1.N00-0AA0 terminal blocks necessary. 64 outputs, 24 V DC, 0.3 A, sink output Note: 6ES7392-4...0-0AA0 connection cable and 6ES7392-1.N00-0AA0 terminal blocks necessary.

Order No. S7-300 connecting cable For 64-channel modules; 2 units 1m 6ES7 322-1BF01-0AA0 6ES7 322-1BH01-0AA0 6ES7 322-1BH10-0AA0 6ES7 322-1BL00-0AA0 6ES7 322-1BP00-0AA0 2.5 m 5m Terminal block For 64-channel modules; 2 units With screw contacts With spring-loaded contacts Front door, elevated design e.g. for 32-channel modules; for connecting 1.3 mm2/ 16 AWG conductors SIMATIC TOP connect Bus connectors 1 unit (spare part) 6ES7 322-8BF00-0AB0 6ES7 322-5GH00-0AB0 6ES7 322-1CF00-0AA0 6ES7 322-1FF01-0AA0 6ES7 322-5FF00-0AB0 6ES7 322-1FH00-0AA0 6ES7 322-1FL00-0AA0 6ES7 322-1HF01-0AA0 6ES7 322-1HF10-0AA0 6ES7 322-5HF00-0AB0 Set of fuses for SM 322 10 fuses 8 A quick-response, 2 fuse holders; for 6ES7 322-1FF01-0AA0, 6ES7 322-1FH00-0AA0 10 fuses 6.3 A; for 6ES7 322-1CF00-0AA0 Labeling strips 10 units (spare part) for modules with 20-pin front connector for modules with 40-pin front connector Label cover 6ES7 322-1HH01-0AA0 10 units (spare part) for modules with 20-pin front connector 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 for modules with 40-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license 6ES7 392-1CJ00-0AA0 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 yellow red For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red

Order No.

6ES7 392-4BB00-0AA0 6ES7 392-4BC50-0AA0 6ES7 392-4BF00-0AA0

6ES7 392-1AN00-0AA0 6ES7 392-1BN00-0AA0 6ES7 328-0AA00-7AA0

6ES7 322-1BP50-0AA0

See Catalog ST 70 6ES7 390-0AA00-0AA0

8 outputs, 24 V DC, 0.5 A, diagnostics-capable 16 outputs, 24/48 V DC, 0.5 A 8 outputs, 48 125 V DC, 1.5 A 8 outputs, 120/230 V AC, 1 A 8 outputs, 120/230 V AC, 2 A 16 outputs, 120/230 V AC, 1 A 32 outputs, 120 V AC, 1 A 8 outputs, relay contacts, 2 A 8 outputs, relay contacts, 5 A 8 outputs, relay contacts, 5 A, with RC filter, overvoltage protection 16 outputs, relay contacts, 8 A Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit

6ES7 973-1HD00-0AA0

6ES7 973-1GC00-0AA0

6ES7 392-2XX00-0AA0 6ES7 392-2XX10-0AA0

6ES7 392-2XY00-0AA0 6ES7 392-2XY10-0AA0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0

5/260

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules


SM 322 digital output module

Ordering data
SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (Programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors

Order No. 6ES7 998-8XC01-8YE0 SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates S7-300 manual Design, CPU data, module data, instruction list German English French Spanish Italian

Order No. 6ES7 998-8XC01-8YE2

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0

Siemens IK PI 2009

5/261

Siemens AG 2008

ET 200M Digital Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 322 digital output module (extended temperature range)

Digital outputs For connecting solenoid valves, contactors, small-power motors, lamps and motor starters

SIPLUS SM 322

16 DO 6AG1 322-1BH01-2AA0 6ES7 322-1BH01-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

SIPLUS SM 322 Order No. Order No. based on Ambient temperature range Environmental conditions

8 DO 48 to 125 VDC 6AG1 322-1CF00-2AA0 6ES7 322-1CF00-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Order No. Order No. based on Ambient temperature range Environmental conditions

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules. 8 DO 6AG1 3221BF01-2XB0 6ES7 3221BF01-0AA0 8 DO 6AG1 3228BF00-2AB0 6ES7 3228BF00-0AB0

The technical data are identical with those of the based-on modules. 8 DO 120/230 VAC 6AG1 322-1FF01-2AA0 6ES7 322-1FF01-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

SIPLUS SM 322 Order No. Order No. based on Ambient temperature range Environmental conditions

SIPLUS SM 322 Order No. Order No. based on Ambient temperature range Environmental conditions

- 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules.

The technical data are identical with those of the based-on modules.

5/262

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules

SIPLUS SM 322 digital output module (extended temperature range)

Overview (continued)
SIPLUS SM 322 Order No. Order No. based on Ambient temperature range Environmental conditions 8 RO 6AG1 322-1HF10-2AA0 6ES7 322-1HF10-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Ordering data
SIPLUS SM 322 digital output modules incl. labeling strips, bus connector 8 outputs, 24 V DC, 2 A 16 outputs, 24 V DC, 0.5 A 32 outputs, 24 V DC, 0.5 A 8 outputs, 24 V DC, 0.5 A, diagnostics-capable 8 outputs, 48 125 V DC, 1.5 A 8 outputs, 120/230 V AC, 1 A The technical data are identical with those of the based-on modules. 8 outputs, relay contacts, 5 A 16 outputs, relay contacts, 8 A Accessories

Order No.

6AG1 322-1BF01-2XB0 6AG1 322-1BH01-2AA0 6AG1 322-1BL00-2AA0 6AG1 322-8BF00-2AB0 6AG1 322-1CF00-2AA0 6AG1 322-1FF01-2AA0 6AG1 322-1HF10-2AA0 6AG1 322-1HH01-2AA0 see Digital output module ordering data

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

SIPLUS SM 322 Order No. Order No. based on Ambient temperature range Environmental conditions

32 DO 6AG1 3221BL00-2AA0 6ES7 3221BL00-0AA0

16 RO 6AG1 3221HH01-2AA0 6ES7 3221HH01-0AA0

- 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules.

Siemens IK PI 2009

5/263

Siemens AG 2008

ET 200M Digital Modules


Overview

SIMATIC ET 200 distributed I/Os

SM 323/SM 327 digital input/output module

Digital inputs and outputs For connecting standard switches, two-wire proximity switches (BERO), solenoid valves, contactors, low-power motors, lamps and motor starters

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs Number of simultaneously controllable inputs, up to 40 C Number of simultaneously controllable inputs, up to 60 C Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. - at "0" to "1", max. - at "1" to "0", min. - at "1" to "0", max.

6ES7 323-1BH01-0AA0

6ES7 323-1BL00-0AA0

6ES7 327-1BH00-0AB0

24 V 40 mA 40 mA 3.5 W 20-pin No 8

24 V 80 mA 80 mA 6.5 W 40-pin No 16

24 V 20 mA 60 mA 3W 20-pin No 8; 8 hard-wired, 8 others individually parameterizable

8 8

16 8

16 16

1,000 m 600 m Yes

1,000 m 600 m Yes

1,000 m 600 m Yes

24 V -30 to +5 V 13 to 30 V 7 mA

24 V -30 to +5 V 13 to 30 V 7 mA

24 V -30 to +5 V 15 to 30 V 6 mA

1.2 ms 4.8 ms 1.2 ms 4.8 ms

1.2 ms 4.8 ms 1.2 ms 4.8 ms

1.2 ms 4.8 ms 1.2 ms 4.8 ms

5/264

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules

SM 323/SM 327 digital input/output module

Technical specifications (continued)


Order No. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. for signal "1" minimum load current Output delay with resistive load "0" to "1", max. "1" to "0", max. Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) vertical installation - up to 40 C, max. horizontal installation - up to 40 C, max. - up to 60 C, max. Load impedance range lower limit upper limit Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Yes 2 mA Yes 1.5 mA Yes 1.5 mA 48 4 k 48 4 k 48 4 k 4A 2A 4A 3A 2A 4A 3A 100 Hz 0.5 Hz 10 Hz 100 Hz 0.5 Hz 100 Hz 100 Hz 0.5 Hz 10 Hz No Yes No Yes No Yes; Outputs of the same group only 100 s 500 s 100 s 500 s 350 s 500 s 5 mA 5 mA 0.5 mA 0.5 mA for signal "0" residual current, max. 0.5 mA 0.5 A 0.5 A 0.5 A 5 mA 0.6 A L+ (-0.8 V) L+ (-0.8 V) L+ (-1.5 V) 8 1,000 m 600 m 1A L+ (-53 V) 5W Yes 16 1,000 m 600 m Yes; Electronic 1A L+ (-48 V) 5W Yes 8; can also be parameterized individually as DI 1,000 m 600 m Yes; Electronic 1A L+ (-54 V) 5W Yes 6ES7 323-1BH01-0AA0 6ES7 323-1BL00-0AA0 6ES7 327-1BH00-0AB0

Short-circuit protection of the output Yes; Electronic

4A

Siemens IK PI 2009

5/265

Siemens AG 2008

ET 200M Digital Modules


Technical specifications (continued)
Order No. Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital output (green) Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels Yes 8 500 VDC Yes Yes No No

SIMATIC ET 200 distributed I/Os

SM 323/SM 327 digital input/output module

6ES7 323-1BH01-0AA0

6ES7 323-1BL00-0AA0

6ES7 327-1BH00-0AB0

No No Yes Yes

No No Yes Yes

500 VDC

500 VDC

Yes 16 Yes; Optocoupler

No

between the channels, in groups of between the channels and the backplane bus Isolation, digital outputs between the channels between the channels, in groups of between the channels and the backplane bus Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx.

Yes; Optocoupler

Yes; Optocoupler

Yes 8 Yes; Optocoupler

Yes 8 Yes; Optocoupler

No

Yes; Optocoupler

75 VDC / 60 VAC

75 VDC / 60 VAC

75 VDC / 60 VAC

40 mm 125 mm 120 mm 220 g

40 mm 125 mm 120 mm 260 g

40 mm 125 mm 120 mm 200 g

5/266

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Digital Modules

SM 323/SM 327 digital input/output module

Ordering data
SM 323 digital input/output modules incl. labeling strips, bus connector 8 inputs, 8 outputs 16 inputs, 16 outputs SM 327 digital input/output modules incl. labeling strips, bus connector 8 inputs, 8 inputs or outputs (can be configured) Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Front door, elevated design e.g. for 32 channel modules; enables connection of 1.3 mm2/16 AWG wires SIMATIC TOP connect Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) for modules with 20-pin front connector for modules with 40-pin front connector Label cover 10 units (spare part) for modules with 20-pin front connector for modules with 40-pin front connector

Order No. S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project 6ES7 323-1BH01-0AA0 6ES7 323-1BL00-0AA0 Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 red For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow 6ES7 392-1CJ00-0AA0 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (Programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates See Catalog ST 70 6ES7 390-0AA00-0AA0 S7-300 manual Design, CPU data, module data, instruction list German English 6ES7 392-2XX00-0AA0 6ES7 392-2XX10-0AA0 French Spanish Italian

Order No.

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 327-1BH00-0AB0

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 328-0AA00-7AA0

6ES7 998-8XC01-8YE2

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0

6ES7 392-2XY00-0AA0 6ES7 392-2XY10-0AA0

Siemens IK PI 2009

5/267

Siemens AG 2008

ET 200M Digital Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 323 digital input/output module (extended temperature range)

Ordering data
SIPLUS SM 323 digital input/output modules incl. labeling strips, bus connector 8 inputs, 8 outputs Accessories

Order No.

6AG1 323-1BH01-2AA0 see Digital input/output modules ordering data

Digital inputs and outputs For connection of switches, 2-wire proximity switches (BERO), solenoid valves, contactors, small-power motors, lamps and motor starters
SIPLUS SM 323 Order No. Order No. based on Ambient temperature range Environmental conditions 8 DI / 8 DO 6AG1 323-1BH01-2AA0 6ES7 323-1BH01-0AA0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules.

5/268

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 331 analog input module

Overview
Analog inputs For connection of voltage and current sensors, thermocouples, resistors and resistance thermometers

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Analog inputs Number of analog inputs Number of analog inputs for resistance measurement cable length, shielded, max. permissible input frequency for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Input ranges (rated values), voltages 0 to +10 V 1 to 5 V 1 to 10 V -1 V to +1 V -10 V to +10 V -2.5 V to +2.5 V -250 mV to +250 mV -5 V to +5 V -50 mV to +50 mV -500 mV to +500 mV -80 mV to +80 mV Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 8 4 200 m; 50 m at 80 mV and with thermocouples 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) 40 mA 200 m 20 V; 20 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) 40 mA 8 8 8 200 m; max. 50 m at 50 mV 30 V; 12 V continuous, 30 V for max. 1 s 40 mA 2 1 200 m; 50 m at 80 mV and with thermocouples 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) 40 mA No Yes No No 20-pin 20-pin 40-pin 20-pin 200 mA 50 mA 1W 50 mA 60 mA 1.5 W 90 mA 0.4 W 80 mA 50 mA 1.3 W 24 V Yes 24 V Yes 24 V Yes 6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0

Siemens IK PI 2009

5/269

Siemens AG 2008

ET 200M Analog Modules


SM 331 analog input module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Input ranges (rated values), currents 0 to 20 mA -10 to +10 mA -20 to +20 mA -3.2 to +3.2 mA 4 to 20 mA Input ranges (rated values), thermoelements Type E Type J Type K Type N Input ranges (rated values), resistors 0 to 150 Ohm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0

0 to 300 Ohm 0 to 600 Ohm 0 to 6000 Ohm Input ranges (rated values), resistance thermometers Ni 100 LG-Ni 1000 Pt 100 Characteristic curve linearization programmable for thermoelements for thermoresistor

Yes; Standard Yes; Standard Yes Type E, J, K, L, N Pt100 (standard, climatic range), Ni100 (standard, climatic range)

Yes; Standard/climate Yes; Standard/AirCon Yes Yes yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/ air con.

Yes Yes Yes Type E, J, K, L, N Pt100 (standard, climatic range), Ni100 (standard, climatic range)

Temperature compensation programmable external temperature compensation with compensations socket internal temperature compensation Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 15 Bit; unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/ 12 bits + sign/ 12 bits + sign/14 bits + sign Yes; 2.5/ 16.67/ 20/ 100 ms 3/ 17/ 22/ 102 ms 52 s per channel 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz 14 Bit; unipolar: 14 bits; bipolar: 13 bits + sign 13 Bit 15 Bit; unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/ 12 bits + sign/ 12 bits + sign/ 14 bits + sign Yes; 2.5/ 16.67/ 20/ 100 ms 6/ 34/ 44/ 204 ms integrating Actual value encryption integrating integrating Yes Yes Yes Yes Yes Yes

Integration time, parameterizable Basic conversion time, including integration time, ms Basic conversion time, ms Interference voltage suppression for interference frequency f1 in Hz

Yes

Yes; 60 / 50 ms 66 / 55 ms 66 / 55 ms 50 / 60 Hz

400 / 60 / 50 / 10 Hz

5/270

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 331 analog input module

Technical specifications (continued)


Order No. Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection Errors/accuracies Operational limit in overall temperature range Voltage, relative to input area +/- 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V) +/- 0,7 %; from 3.2 to 20 mA +/- 0,7 %; 150, 300, 600 Ohm +/- 0,7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate) +/- 0,4 % +/- 0,6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5% (+/-50 mV, 500 mV, 1 V) +/- 0,5 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA +/- 0,5 %; 0 to 6 kohms, 0 to 600 kohms +/- 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V) +/- 0,7 %; from 3.2 to 20 mA +/- 0,7 %; 150, 300, 600 Ohm +/- 0,7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate) Yes Yes Yes Yes Yes Yes Yes Yes; with external supply Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0

Current, relative to input area Impedance, relative to input area Resistance-type thermometer, relative to input area Basic error limit (operational limit at 25 C) Voltage, relative to input area

+/- 0,3 %

+/- 0,6 %; +/-0.4% (250 to 1000 mV); +/-0.6% (2.5 to 10 mV); +/-0.7% (80 mV) +/- 0,5 %; 3.2 to 20 mA +/- 0,5 %; 150, 300, 600 Ohm +/- 0,6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate)

+/- 0,25 %

+/- 0,4 %

+/- 0.6 %; +/-0.6% (80 mV, 2.5 to 10 V); +/-0.4% (250 to 1000 mV) +/- 0,5 %; 3.2 to 20 mA +/- 0,5 %; 150, 300, 600 Ohm +/- 0.6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate)

Current, relative to input area Impedance, relative to input area

+/- 0,2 %

+/- 0,3 %; +/-20mA,0-20mA,4-20mA +/- 0,3 %; 0 to 6 kohms, 0 to 600 kohms

Resistance-type thermometer, relative to input area Status information/ alarms/diagnostics Alarms Diagnostic alarm Limit value alarm Diagnoses Diagnostic information readable Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx.

Yes; parameterizable, channels 0 and 2 Yes; parameterizable

Yes; Parameterizable Yes; parameterizable, channels 0 and 2 Yes 500 VDC

No No

Yes Yes; parameterizable, channel 0 Yes 500 VDC

Yes 500 VDC

No 500 VDC

No Yes

No Yes

No Yes

No Yes

40 mm 125 mm 120 mm 250 g

40 mm 125 mm 120 mm 200 g

40 mm 125 mm 117 mm 250 g

40 mm 125 mm 120 mm 250 g Siemens IK PI 2009

5/271

Siemens AG 2008

ET 200M Analog Modules


SM 331 analog input module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Analog inputs Number of analog inputs 8 8 200 m 75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) 100 m 75 V; 20 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) 200 m 50 V; permanent 200 m 75 V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20) 40 mA 8 8 8 Number of analog inputs for resistance measurement cable length, shielded, max. permissible input frequency for voltage input (destruction limit), max. permissible input current for current input (destruction limit), max. Input ranges (rated values), voltages 1 to 5 V -10 V to +10 V -5 V to +5 V Input ranges (rated values), currents 0 to 20 mA -20 to +20 mA 4 to 20 mA Input ranges (rated values), thermoelements Type B Type E Type J Type K Type L Type N Type R Type S Type T Type U Typ TXK/TXK(L) to GOST Input ranges (rated values), resistors 0 to 150 Ohm 0 to 300 Ohm 0 to 600 Ohm Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No 40-pin 40-pin 40-pin 40-pin 240 mA 100 mA 4.6 W 200 mA 100 mA 3W 130 mA 0.6 W 200 mA 100 mA 3W 24 V Yes 24 V Yes 24 V Yes 6ES7 331-7PF01-0AB0 6ES7 331-7PF11-0AB0 6ES7 331-7NF00-0AB0 6ES7 331-7NF10-0AB0

32 mA

5/272

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 331 analog input module

Technical specifications (continued)


Order No. Input ranges (rated values), resistance thermometers Cu 10 Ni 100 Ni 1000 Ni 120 Ni 200 Ni 500 Pt 100 Pt 1000 Pt 200 Pt 500 Characteristic curve linearization programmable for thermoelements for thermoresistor Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10; (standard/climate) Yes Yes Yes Yes Yes Yes Type B, E, J, K, L, N, R, S. T, U, C Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 331-7PF01-0AB0 6ES7 331-7PF11-0AB0 6ES7 331-7NF00-0AB0 6ES7 331-7NF10-0AB0

Temperature compensation programmable external temperature compensation with compensations socket external temperature compensation with Pt100 internal temperature compensation Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 16 Bit; Twos complement 16 Bit; Twos complement 16 Bit; unipolar: 15/15/15/15 bits; bipolar: 15 bits + sign/ 15 bits + sign/15 bits + sign/15 bits + sign Yes; 10 / 16.67 / 20 / 100 ms 16 Bit; unipolar: 15/15/15/15 bits; bipolar: 15 bits + sign/ 15 bits + sign/15 bits + sign/15 bits + sign Yes; 23 / 72 / 83 / 95 ms 10 ms (4-channel mode); 95/83/72/23 ms (8-channel mode) 400 / 60 / 50 / 10 Hz 400 / 60 / 50 Hz, combinations of 400, 60, 50 Hz integrating integrating integrating integrating

Integration time, parameterizable Basic conversion time, ms

Yes up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms 400 / 60 / 50 Hz

Yes up to 4 channels: 10 ms per module, as of 5 channels: 190 ms per module 400 / 60 / 50 Hz

Interference voltage suppression for interference frequency f1 in Hz Encoder Connection of signal encoders for current measurement as 2-wire transducer

Yes; with external transmitter; possible with separate supply for transmitter Yes Yes; without resistance correction Yes Yes

Yes; with external transmitter, current supply; possible with separate supply for transmitter Yes

for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection

Siemens IK PI 2009

5/273

Siemens AG 2008

ET 200M Analog Modules


SM 331 analog input module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Errors/accuracies Operational limit in overall temperature range Voltage, relative to input area Current, relative to input area Impedance, relative to input area Basic error limit (operational limit at 25 C) Voltage, relative to input area Current, relative to input area Impedance, relative to input area Status information/ alarms/diagnostics Alarms Diagnostic alarm Yes; parameters can be set per group Yes; parameterizable Yes; parameters can be set per group Yes; parameterizable Yes; Parameterizable Yes; parameterizable, channels 0 and 2 Yes; Parameterizable Yes; parameterizable all channels (end of cycle interrupt is also supported across modules) Yes 500 V AC +/- 0,05 % +/-0.5 K +/- 0,05 % +/- 0,05 % +/- 0,05 % +/- 0,05 % +/- 0,1 % +/-1 K +/- 0,1 %; +/-0.7% +/- 0,3 %; +/-0.9% +/- 0,1 % +/- 0,1 % 6ES7 331-7PF01-0AB0 6ES7 331-7PF11-0AB0 6ES7 331-7NF00-0AB0 6ES7 331-7NF10-0AB0

Limit value alarm

Diagnoses Diagnostic information readable Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 272 g 272 g 272 g 272 g 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm Yes 2 Yes Yes 2 Yes Yes Yes 2 Yes 500 VDC 500 VDC 500 VDC Yes Yes Yes

5/274

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 331 analog input module

Ordering data
SM 331 analog input modules Including labeling strips, bus connector, measuring range modules 8 inputs, 13-bit resolution 8 inputs, resolution 9/12/14 bits 2 inputs, resolution 9/12/14 bits 8 inputs, enhanced resolution 16 bits 8 inputs, enhanced resolution 16 bits, 4-channel mode 8 inputs, resolution 14 bits, for isochronous mode 8 inputs, for thermal resistors 8 inputs, for thermoelements Measuring range module for analog inputs 1 module for 2 analog inputs; 2 units (spare part) Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Front door, elevated design e.g. for 32-channel modules; for connecting 1.3 mm2/ 16 AWG wires SIMATIC TOP connect Bus connectors 1 unit (spare part) Shield connecting element 80 mm wide, with 2 rows for 4 terminal elements each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

Order No. Label cover 10 units (spare part), for modules with 20-pin front connector 6ES7 331-1KF01-0AB0 6ES7 331-7KF02-0AB0 6ES7 331-7KB02-0AB0 6ES7 331-7NF00-0AB0 6ES7 331-7NF10-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-7PF01-0AB0 6ES7 331-7PF11-0AB0 6ES7 974-0AA00-0AA0 Labeling strips 10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine labeling For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 red For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 light-beige yellow red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates S7-300 manual See Catalog ST 70 6ES7 390-0AA00-0AA0 6ES7 390-5AA00-0AA0 Design, CPU data, module data, instruction list German English French Spanish Italian

Order No. 6ES7 392-2XY00-0AA0

6ES7 392-2XX00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 328-0AA00-7AA0

6ES7 998-8XC01-8YE2

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

Siemens IK PI 2009

5/275

Siemens AG 2008

ET 200M Analog Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 331 analog input module (extended temperature range)

Analog inputs Connecting voltage sensors and current sensors, thermo elements, resistors and resistance thermometers

SIPLUS SM 321

2 AI 6AG1 3317KB02-2AB0 6ES7 3317KB02-0AB0

8 AI 6AG1 3317KF02-2AB0 6ES7 3317KF02-0AB0

8 AI, 16 bit 6AG1 3317NF00-2AB0 6ES7 3317NF00-0AB0

8 AI, 16 bit 6AG1 3317NF10-2AB0 6ES7 3317NF10-0AB0

8 AI, 40-pole 6AG1 3317PF01-2AB0 6ES7 3317PF01-0AB0

Order No. Order No. based on Ambient temperature range Environmental conditions Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

- 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes No Yes No No

The technical data are identical with those of the based-on modules. Order No.

Ordering data
SIPLUS SM 331 analog input modules Including labeling strips, bus connector, measuring range modules 8 inputs, resolution 9/12/14 bits 2 inputs, resolution 9/12/14 bits 8 inputs, enhanced resolution 16 bits 8 inputs, enhanced resolution 16 bits, 4-channel mode 8 inputs, for thermal resistors Accessories

6AG1 331-7KF02-2AB0 6AG1 331-7KB02-2AB0 6AG1 331-7NF00-2AB0 6AG1 331-7NF10-2AB0

6AG1 331-7PF01-2AB0 see Analog input modules ordering data

5/276

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 332 analog output module

Overview
Analog outputs For the connection of analog actuators

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Output ranges, voltage 0 to 10 V 1 to 5 V -10 to +10 V Output ranges, current 0 to 20 mA -20 to +20 mA 4 to 20 mA Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. 1 k 1 F 500 10 milliH 1 k 1 F 500 10 milliH 1 k 1 F 500 10 milliH 1 k 1 F 500 1 milliH Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 200 m Yes 25 mA 18 V 4 200 m Yes 25 mA 18 V 8 200 m Yes 25 mA 18 V 4; isochronous mode 200 m Yes 40 mA 18 V 20-pin 20-pin 40-pin 20-pin 135 mA 60 mA 3W 240 mA 60 mA 3W 340 mA 100 mA 6W 290 mA 120 mA 3W 24 V 24 V 24 V 24 V 6ES7 332-5HB01-0AB0 6ES7 332-5HD01-0AB0 6ES7 332-5HF00-0AB0 6ES7 332-7ND02-0AB0

Siemens IK PI 2009

5/277

Siemens AG 2008

ET 200M Analog Modules


SM 332 analog output module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. 12 Bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits 0.8 ms 12 Bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits 0.8 ms 12 Bit; +/-10 V, +/-20 mA, 4 to 20 mA, 1 to 5 V: 11 bits + sign; 0 to 10 V, 0 to 20 mA: 12 bits 0.8 ms 16 Bit 6ES7 332-5HB01-0AB0 6ES7 332-5HD01-0AB0 6ES7 332-5HF00-0AB0 6ES7 332-7ND02-0AB0

Conversion time (per channel) Settling time for resistive load for capacitive load for inductive load Errors/accuracies

200 s; in isochronous mode 640 s 0.2 ms 3.3 ms 0.5 ms

0.2 ms 3.3 ms 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)

0.2 ms 3.3 ms 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)

0.2 ms 3.3 ms 0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)

Operational limit in overall temperature range Voltage, relative to output area Current, relative to output area Basic error limit (operational limit at 25 C) Voltage, relative to output area Current, relative to output area Status information/ alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Diagnoses Diagnostic information readable Isolation Isolation checked with Isolation Isolation, analog outputs between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 220 g 220 g 272 g 220 g 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm Yes Yes Yes Yes 500 VDC 500 VDC 500 VDC 1500 V DC Yes Yes Yes Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable Yes Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable +/- 0,4 % +/- 0,5 % +/- 0,4 % +/- 0,5 % +/- 0,4 % +/- 0,5 % +/- 0,02 % +/- 0,02 % +/- 0,5 % +/- 0,6 % +/- 0,5 % +/- 0,6 % +/- 0,5 % +/- 0,6 % +/- 0,12 % +/- 0,18 %

5/278

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules


SM 332 analog output module

Ordering data
SM 332 analog output modules incl. labeling strips, bus connector 4 outputs, 11/12 bit 4 outputs, 16 bit 2 outputs, 11/12 bit 8 outputs, 11/12 bit Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Front door, elevated design e.g. for 32-channel modules; for connecting 1.3 mm2/ 16 AWG wires SIMATIC TOP connect Bus connectors 1 unit (spare part) Shield connecting element 80 mm wide, with 2 rows for 4 terminal elements each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter Label cover 10 units (spare part), for modules with 20-pin front connector Labeling strips 10 units (spare part), for modules with 20-pin front connector

Order No. S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine labeling For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 red For 32-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red SIMATIC Manual Collection 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 328-0AA00-7AA0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates S7-300 manual Design, CPU data, module data, instruction list German English 6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0 6ES7 392-2XY00-0AA0 French Spanish Italian

Order No.

6ES7 332-5HD01-0AB0 6ES7 332-7ND02-0AB0 6ES7 332-5HB01-0AB0 6ES7 332-5HF00-0AB0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-2AX10-0AA0 6ES7 392-2BX10-0AA0 6ES7 392-2CX10-0AA0 6ES7 392-2DX10-0AA0 6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

See Catalog ST 70 6ES7 390-0AA00-0AA0 6ES7 390-5AA00-0AA0

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0

6ES7 392-2XX00-0AA0

Siemens IK PI 2009

5/279

Siemens AG 2008

ET 200M Analog Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 332 analog output module (extended temperature range)

Ordering data
SIPLUS SM 332 analog output modules incl. labeling strips, bus connector 2 outputs, 11/12 bit 8 outputs, 11/12 bit

Order No.

6AG1 332-5HB01-2AB0 6AG1 332-5HF00-2AB0

Analog outputs For connection of analog actuators

SIPLUS SM 321 Order No. Order No. based on Ambient temperature range Environmental conditions

2 AO 6AG1 3325HB01-2AB0 6ES7 3325HB01-0AB0

8 AO 6AG1 3325HF00-2AB0 6ES7 3325HF00-0AB0

- 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) Yes No

Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). Technical specifications

The technical data are identical with those of the based-on modules.

5/280

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules

SM 334 analog input/output module

Overview
Analog inputs and outputs For the connection of analog sensors and actuators

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Analog inputs Number of analog inputs Number of analog inputs for voltage measurement Number of analog inputs for resistance measurement permissible input frequency for voltage input (destruction limit), max. 20 V 4 4 4 2 4 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) 20-pin 20-pin 110 mA 55 mA 3W 80 mA 60 mA 2W 24 V 24 V 6ES7 3340CE01-0AA0 6ES7 3340KE00-0AB0 Order No. Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Output ranges, voltage 0 to 10 V Output ranges, current 0 to 20 mA Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Analog value creation 85 ms Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Yes Yes Integration time, ms Settling time Yes for resistive load for capacitive load for inductive load Yes 0.3 ms 3 ms 0.3 ms 0.8 ms 0.8 ms 8 Bit 12 Bit 16,67 / 20 5 k 1 F 300 1 milliH 2.5 k 1 F Yes Yes Yes 2 200 m Yes 11 mA 15 V 2 100 m Yes 10 mA 6ES7 3340CE01-0AA0 6ES7 3340KE00-0AB0

permissible input current for current input (destruction limit), max. Cycle time (all channels), max. Input ranges (rated values), voltages 0 to +10 V Input ranges (rated values), currents 0 to 20 mA Input ranges (rated values), resistors 0 to 10000 Ohm Input ranges (rated values), resistance thermometers Pt 100

40 mA 5 ms

Yes; only climatic range

Siemens IK PI 2009

5/281

Siemens AG 2008

ET 200M Analog Modules


Technical specifications (continued)
Order No. Encoder Connection of signal encoders for current measurement as 4-wire transducer for resistance measurement with 2-conductor connection for resistance measurement with 3-conductor connection for resistance measurement with 4-conductor connection Errors/accuracies Operational limit in overall temperature range Voltage, relative to input area Current, relative to input area +/- 0,9 % +/- 0,8 % Yes

SIMATIC ET 200 distributed I/Os

SM 334 analog input/output module

Ordering data
6ES7 3340KE00-0AB0 SM 334 analog input/output modules incl. labeling strips, bus connector 4 inputs, 2 outputs Yes Yes Yes 4 inputs, 2 outputs, resistance measurement, Pt 100 Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded terminals 1 unit +/- 0,7 %; 0 to 10 V +/- 3,5 %; 10 kOhm +/- 1 % 100 units 20-pin, with FastConnect 1 unit Front door, elevated design e.g. for 32-channel modules; for connecting 1.3 mm2/ 16 AWG wires SIMATIC TOP connect Bus connectors 1 unit (spare part) Shield connecting element 80 mm wide, with 2 rows for 4 terminal elements each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter Label cover 10 units (spare part), for modules with 20-pin front connector Labeling strips

Order No.

6ES7 3340CE01-0AA0

6ES7 334-0CE01-0AA0 6ES7 334-0KE00-0AB0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 328-0AA00-7AA0

Impedance, relative to input area Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area Basic error limit (operational limit at 25 C) Voltage, relative to input area Current, relative to input area Impedance, relative to input area Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area Status information/ alarms/diagnostics Alarms Alarms Diagnoses Diagnostic functions Isolation Isolation checked with Isolation Isolation, analog inputs between the channels and the backplane bus Isolation, analog outputs between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 285 g 40 mm 125 mm 120 mm No No 500 VDC No No +/- 0,5 % +/- 0,5 % +/- 0,7 % +/- 0,6 % +/- 0,6 % +/- 1 %

+/- 1 %

See Catalog ST 70 6ES7 390-0AA00-0AA0 6ES7 390-5AA00-0AA0

+/- 0,5 %; 0 to 10 V +/- 2,8 %; 10 kOhm +/- 0,8 % +/- 0,85 %

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0 6ES7 392-2XY00-0AA0

No No 500 VDC

6ES7 392-2XX00-0AA0

10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project

Yes

Single license Upgrade single license

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

Yes

40 mm 125 mm 120 mm 200 g

5/282

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules

SM 334 analog input/output module

Ordering data
Labeling sheets for machine labeling For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors

Order No. SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates 6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0 S7-300 manual Design, CPU data, module data, instruction list German English French Spanish Italian

Order No. 6ES7 998-8XC01-8YE2

6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0

Siemens IK PI 2009

5/283

Siemens AG 2008

ET 200M Analog Modules


Overview

SIMATIC ET 200 distributed I/Os

SIPLUS SM 334 analog input/output module (extended temperature range)

Ordering data
SIPLUS SM 334 analog input/output modules incl. labeling strips, bus connector 4 inputs, 2 outputs, resistance measurement, Pt 100

Order No. 6AG1 334-0KE00-2AB0

Analog inputs and outputs For connection of analog sensors and actuators

SIPLUS SM 334 Order No. Order No. based on Ambient temperature range Environmental conditions

2 AO 6AG1 334-0KE00-2AB0 6ES7 334-0KE00-0AB0 - 25 ... + 60 C, condensation permitted Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) The technical data are identical with those of the based-on modules.

Technical specifications

5/284

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules with HART


Analog input module with HART

Overview
Can only be plugged into ET 200M with IM 153-2 and IM 153-2 FO 8 AI HART Redundancy switching Firmware update HART minor variables

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Isochronous mode Isochronouos mode Analog inputs Number of analog inputs cable length, shielded, max. permissible input current for current input (destruction limit), max. Input ranges (rated values), currents 0 to 20 mA Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, parameterizable Integration time, ms 16 Bit Yes 20ms@50Hz / 16.6ms@60Hz / 100ms@100Hz 65ms@50Hz / 55ms@60Hz / 305ms@100Hz Sigma Delta Yes 8 800 m 40 mA No 20 mA 120 mA 1.5 W 24 V Yes 6ES7 331-7TF01-0AB0 Order No. Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer Errors/accuracies Operational limit in overall temperature range Current, relative to input area Basic error limit (operational limit at 25 C) Current, relative to input area Status information/ alarms/diagnostics Alarms Diagnostic alarm Limit value alarm Diagnoses Diagnostic information readable Isolation Isolation checked with Isolation Isolation, analog inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 205 g 40 mm 125 mm 117 mm No 8 Yes 500 Yes Yes Yes 0,1 +/- % 0,15 +/- % Yes Yes 6ES7 331-7TF01-0AB0

Basic conversion time, including integration time, ms

Siemens IK PI 2009

5/285

Siemens AG 2008

ET 200M Analog Modules with HART


Analog input module with HART

SIMATIC ET 200 distributed I/Os

Ordering data
SM 331 HART analog input module 8 inputs, 0/4 20 mA, HART for ET 200M with IM 153-2 interface module Accessories Front connectors 20-pin, with screw-type contacts - 1 unit - 100 units 20-pin, with spring contacts - 1 unit - 100 units 20-pin, with FastConnect - 1 unit LK 393 cable guide Mandatory for operation in hazardous areas SIMATIC DP DIN rail for ET 200M For insertion of up to 5 bus modules for Length: 483 mm (19) Length: 530 mm

Order No. 6ES7 331-7TF01-0AB0 SIMATIC S7-300 DIN rail Length: 160 mm Length: 480 mm (19) Length: 530 mm Length: 830 mm Length: 2,000 mm Label cover 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 393-4AA00-0AA0 (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM Labeling strips (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM S7-SmartLabel V3.0 Software for machine labeling of modules directly from the STEP 7 project Single license Upgrade single license 6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 Labeling sheets for machine printing For 16-channel signal modules, DIN A4, for printing with laser printers; 10 units petrol light beige yellow red

Order No.

6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 6ES7 392-2XY00-0AA0

6ES7 392-2XX00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

5/286

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules with HART


SIPLUS SM 331 HART analog input module

Overview

Ordering data
SM 331 HART analog input module 2 inputs, 0/4 to 20 mA, HART for ET 200M with IM 153-2 interface module

Order No. 6AG1 331-7TB00-4AB0

For connecting HART devices in hazardous areas. Plug exclusively into ET 200M:
SIPLUS SM 331 HART analog input module Order No. Order No. based on Environmental conditions 6AG1 331-7TB00-4AB0 6ES7 331-7TB00-0AB0 Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere) The technical data are identical with those of the based-on modules.

Technical data

Siemens IK PI 2009

5/287

Siemens AG 2008

ET 200M Analog Modules with HART


Analog output module with HART

SIMATIC ET 200 distributed I/Os

Overview
For plugging into ET 200M exclusively with IM 153-2 and IM 153-2 FO 8 AO HART Redundancy switching Firmware update HART minor variables

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Analog outputs Number of analg outputs cable length, shielded, max. Current output, no-load voltage, max. Output ranges, current 0 to 20 mA -20 to +20 mA 4 to 20 mA Load impedance (in rated range of output) with current outputs, max. with current outputs, inductive load, max. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Settling time for resistive load for inductive load

6ES7 332-8TF01-0AB0

Order No. Errors/accuracies Operational limit in overall temperature range Current, relative to output area

6ES7 332-8TF01-0AB0

24 V 350 mA 110 mA 6W 8 800 m 24 V

0,2 +/- %

Basic error limit (operational limit at 25 C) Current, relative to output area Status information/ alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Diagnoses Diagnostic information readable Yes Isolation Isolation, analog outputs between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 220 g 40 mm 125 mm 117 mm Yes Yes Yes 0,1 +/- %

Yes No Yes

750 10 milliH

16 Bit

0.1 ms 0.5 ms

5/288

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules with HART


Analog output module with HART

Ordering data
SM 332 HART analog output module HART analog output, 8 outputs, 0/4 20 mA, HART for ET 200M with IM 153-2 Accessories Front connector (1 unit) 20-pin, with screw contacts LK 393 cable guide Mandatory for operation in hazardous areas SIMATIC DP mounting rail for ET 200M For mounting of up to 5 bus modules for Length: 483 mm Length: 530 mm SIMATIC S7-300 mounting rail Length: 160 mm Length: 480 mm Length: 530 mm Length: 830 mm Length: 2000 mm Reference manual EX-I/O S7-300U, M7-300, ET 200M German English Label cover (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM Labeling strips (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM

Order No. 6ES7 332-8TF01-0AB0 S7 Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates S7-SmartLabel V3.0 6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 Software for machine labeling of modules directly from the STEP 7 project Single License Upgrade Single License Labeling sheets for machine printing For 16-channel signal modules, DIN A4, for printing with laser printers; 10 units petrol light beige yellow 6ES7 398-8RA00-8AA0 6ES7 398-8RA00-8BA0 6ES7 392-2XY00-0AA0 red

Order No. 6ES7 998-8XC01-8YE0

6ES7 392-1AJ00-0AA0 6ES7 393-4AA00-0AA0

6ES7 998-8XC01-8YE2

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

5
6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

6ES7 392-2XX00-0AA0

Siemens IK PI 2009

5/289

Siemens AG 2008

ET 200M Analog Modules with HART


Ex-analog input module with HART

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications (continued)


Order No. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Integration time, parameterizable Integration time, ms Basic conversion time, including integration time, ms 16 Bit; 10 to 15 bits + sign Yes 2.5 / 16.67 / 20 / 100 ms 2.5 / 16.67 / 20 / 100 (1 channel enabled); 7.5 / 50 / 60 / 300 (2 channels enabled) Sigma Delta 6ES7 331-7TB00-0AB0

Interference voltage suppression 10 / 50 / 60 / 400 Hz for interference frequency f1 in Hz Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer Ex(i) characteristics Module for Ex(i) protection Max. values of input circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. 24 V Yes Yes 15 V; at 22 mA Yes; approx. 30 mA 29.6 V 100 mA 180 mA 4.5 W 2 400 m 40 mA Po (power of load), max. Uo (output no-load voltage), max. Um (fault voltage), max. Ta (permissible ambient temperature), max. Errors/accuracies Crosstalk between the inputs, min. Operational limit in overall temperature range Current, relative to input area Basic error limit (operational limit at 25 C) Current, relative to input area Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 60 db (peak value of interference < rated value of input range), min. Yes Yes 50 Yes 50 common mode voltage, min. 130 db 0,1 +/- %; from 0/4 to 20 mA 0,45 +/- %; from 0/4 to 20 mA 130 db 62 nF 96.1 mA 3 milliH 511 mW 26 V 250 V; DC 0.6 C Yes Yes Yes

For connecting HART devices in hazardous areas Can only be plugged into ET 200M 2 AI HART, Ex 2 inputs in 2 channel groups (single-channel isolation) Measurement type/range can be selected for each channel Diagnostics and diagnostic alarm parameterizable

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Voltage supply to the transducers present Rated value (DC) short-circuit proof No-load voltage (DC) Current consumption from backplane bus DC 5 V, max. from supply voltage L+, max. Power loss, typ. Analog inputs Number of analog inputs cable length, shielded, max. permissible input current for current input (destruction limit), max. Input ranges (rated values), currents Current 0 to 20 mA Input resistance (0 to 20 mA) 4 to 20 mA Input resistance (4 to 20 mA) 6ES7 331-7TB00-0AB0

5/290

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules with HART


Ex-analog input module with HART

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Limit value alarm Diagnoses Diagnostic functions Diagnostic information readable Overrange Short circuit of the signal encoder cable HART communication, active Diagnostics indication LED Collective error SF (red) Channel error indicator F (red) Isolation tested with Channels against backplane bus and load voltage L+ Channels among one another Load voltage L+ against backplane bus Isolation between the channels and backplane bus Isolation, analog inputs Isolation, analog inputs Isolation, analog outputs between the channels between the channels and the load voltage L+ Permissible potential difference between the inputs (UCM) Environmental requirements Operating termperature max. Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM [EEx ib] IIC Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, Group IIC T4 II3 (2) G Eex nA [ib] IIC T4 KEMA 97; ATEX3039 X 60 C 60 V DC / 30 V AC Yes Yes Yes Yes 1500 V AC 1500 V AC 500 V DC Yes Yes Yes; parameterizable, red LED, alarm message Yes Yes; red LED, signal Yes; red LED, signal Yes; green LED (H) Yes; Parameterizable Yes; parameterizable, channels 0 and 1 6ES7 331-7TB00-0AB0

Ordering data
SM 331 HART analog input module 2 inputs, 0/4 20 mA, HART for ET 200M with IM 153-2 interface module Accessories Front connector 1) 20-pin, with screw contacts 1 unit 100 units LK 393 cable guide Mandatory for operation in hazardous areas SIMATIC DP mounting rail for ET 200M For mounting of up to 5 bus modules for Length: 483 mm Length: 530 mm SIMATIC S7-300 mounting rail Length: 160 mm Length: 480 mm Length: 530 mm Length: 830 mm Length: 2000 mm Reference manual EX-I/O S7-300U, M7-300, ET 200M German English Label cover (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM Labeling strips (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM S7-SmartLabel V3.0 Software for machine labeling of modules directly from the STEP 7 project Single License Upgrade Single License Labeling sheets for machine printing For 16-channel signal modules, DIN A4, for printing with laser printers; 10 units petrol light beige

Order No. 6ES7 331-7TB00-0AB0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 393-4AA00-0AA0

Wire break in signal encoder cable Yes; red LED, signal

6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0

6ES7 398-8RA00-8AA0 6ES7 398-8RA00-8BA0 6ES7 392-2XY00-0AA0

6ES7 392-2XX00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

Type of protection to KEMA Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx.

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

40 mm 125 mm 120 mm 260 g

yellow red
1)

A connector with spring-loaded terminals cannot be used if the cable guide is used.

Siemens IK PI 2009

5/291

Siemens AG 2008

ET 200M Analog Modules with HART


Ex-analog output module with HART

SIMATIC ET 200 distributed I/Os

Overview
For using HART devices in hazardous areas. Can only be plugged into ET 200M 2 AO HART, Ex 2 current outputs in 2 channel groups (single-channel isolation) Output type and range can be selected for each channel Diagnostics and diagnostic alarm parameterizable Read-back capability of the analog outputs

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection Current consumption from backplane bus DC 5 V, max. from supply voltage L+, max. Power loss, typ. Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Current output, no-load voltage, max. Cycle time (all channels) max. Output ranges, current 0 to 20 mA 4 to 20 mA Connection of actuators for current output 2-conductor connection Load impedance (in rated range of output) with current outputs, max. with current outputs, inductive load, max. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Conversion time (per channel) Settling time for resistive load for capacitive load for inductive load

6ES7 332-5TB00-0AB0

Order No. Ex(i) characteristics Module for Ex(i) protection

6ES7 332-5TB00-0AB0 Yes

24 V Yes 100 mA 150 mA 3.5 W 2 400 m Yes 19 V 5 ms Yes Yes Yes

Max. values of output circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Uo (output no-load voltage), max. Um (fault voltage), max. Ta (permissible ambient temperature), max. Errors/accuracies Crosstalk between the outputs, min. 130 db Operational limit in overall temperature range Current, relative to output area Basic error limit (operational limit at 25 C) Current, relative to output area 0,15 +/- % 0,55 +/- % 230 nF 66 mA 7.5 milliH 506 mW 19 V 60 V; DC 60 C

650 7.5 milliH

12 Bit; Output value; 8 bit (+ sign) read back value 40 ms 2.5 ms 4 ms 2.5 ms

5/292

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Analog Modules with HART


Ex-analog output module with HART

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Substitute values connectable Alarms Diagnostic alarm Diagnoses Diagnostic functions Diagnostic information readable Diagnostics Overrange Wire break Wire break in acutator cable HART communication, active Diagnostics indication LED Collective error SF (red) Channel error indicator F (red) Isolation tested with Channels against backplane bus and load voltage L+ Channels among one another Load voltage L+ against backplane bus 1500 V AC 1500 V AC 500 V DC Yes; Additional group message per channel Yes; per channel Yes; parameterizable Yes Yes Yes Yes; as of output value > 0.5 mA Yes Yes; green LED (H) Yes; Parameterizable Yes; Parameterizable 6ES7 332-5TB00-0AB0 Order No. Isolation between the channels and backplane bus Isolation, analog outputs Galvanic isolation, analog outputs between the channels between the channels and the load voltage L+ Permissible potential difference between the outputs (UCM) between M internally and the outputs Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM [Eex ib] IIC Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, Group IIC T4 II3 (2) G Eex nA [ib] IIC T4 97 ATEX 2359 X 60 V DC/30 V AC 60 V DC / 30 V AC Yes Yes Yes Yes 6ES7 332-5TB00-0AB0

Type of protection to KEMA Test number KEMA Dimensions Dimensions Width Height Depth Weights Weight, approx.

40 mm 125 mm 120 mm 280 g

Siemens IK PI 2009

5/293

Siemens AG 2008

ET 200M Analog Modules with HART


Ex-analog output module with HART

SIMATIC ET 200 distributed I/Os

Ordering data
SM 332 HART analog output module HART analog output, 8 outputs, 0/4 20 mA, HART for ET 200M with IM 153-2 Accessories Front connectors 20-pin, with screw contacts 1 unit 100 units LK 393 cable guide Mandatory for operation in hazardous areas SIMATIC DP mounting rail for ET 200M For mounting of up to 5 bus modules for Length: 483 mm

Order No. 6ES7 332-5TB00-0AB0 Label cover (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM Labeling strips (10 units, spare part) for signal modules (not 32-channel modules), function modules and CPU 312 IFM S7-SmartLabel V3.0 Software for machine labeling of modules directly from the STEP 7 project Single License Upgrade Single License Labeling sheets for machine printing 6ES7 195-1GA00-0XA0 6ES7 195-1GF30-0XA0 6ES7 390-1AB60-0AA0 6ES7 390-1AE80-0AA0 6ES7 390-1AF30-0AA0 6ES7 390-1AJ30-0AA0 6ES7 390-1BC00-0AA0 For 16-channel signal modules, DIN A4, for printing with laser printers; 10 units petrol light beige yellow red S7 Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No. 6ES7 392-2XY00-0AA0

6ES7 392-2XX00-0AA0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 393-4AA00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

Length: 530 mm SIMATIC S7-300 mounting rail Length: 160 mm Length: 480 mm Length: 530 mm Length: 830 mm Length: 2000 mm Reference manual EX-I/O S7-300U, M7-300, ET 200M German English

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

6ES7 398-8RA00-8AA0 6ES7 398-8RA00-8BA0

6ES7 998-8XC01-8YE2

5/294

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Ex Digital Modules


Ex digital input modules

Overview
Digital inputs for signals from the Ex field For the connection of intrinsically safe digital equipment from the Ex field 4 DI NAMUR 4 digital inputs in 4 channel modules (single-channel isolation) Connectable encoder in accordance with DIN EN 60947-5-6 and NAMUR, optionally with wired or unwired mechanical contacts Diagnostics and diagnostics alarm programmable

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital inputs Number of NAMUR inputs Cable length Cable length unshielded, max. Input voltage Rated value, DC Input current on wire break, max. on short -circuit, max. for NAMUR encoders - for signal "0" - for signal "1" Input delay (for rated value of input voltage) Input frequency (with 0.1 ms delay), max. for NAMUR inputs - programmable Encoder supply Output voltage via the inputs 2 kHz Test number PTB Weights Yes; 0.1 / 0.5 / 3 / 15 / 20 ms (plus 0.25 ms preparation time) Weight, approx. 230 g 0.1 mA 8.5 mA 0.35 to 1.2 mA 2.1 to 7 mA 8.2 V; from internal power circuit supply 200 m 4 20-pin 50 mA 80 mA 1.1 W 24 V 6ES7 321-7RD00-0AB0 Order No. Encoder Connectable encoders NAMUR encoder Ex(i) characteristics Max. values of input circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Uo (output no-load voltage), max. Status information/ alarms/diagnostics Diagnoses Diagnostic information readable Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs between the channels, in groups of Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM [EEx ib] IIC Class II, Division 2, Group A, B, C, D T4 Ex-96.D.2094X Yes 1 Yes 3 F 14.1 mA 100 milliH 33.7 mW 10 V Yes; Two-wire connection 6ES7 321-7RD00-0AB0

Siemens IK PI 2009

5/295

Siemens AG 2008

ET 200M Ex Digital Modules


Ex digital input modules

SIMATIC ET 200 distributed I/Os

Ordering data
Ex digital input module 4 inputs, isolated, NAMUR Front connectors 20-pin, with screw contacts 1 unit 100 units Front door, elevated design e.g. for 32 channel modules; enables connection of 1.3 mm2/16 AWG wires LK 393 cable guide Mandatory for operation in Ex-hazard areas Labeling strips 10 units (spare part), for modules with 20-pin front connector Label cover

Order No. Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 328-0AA00-7AA0 petrol light-beige yellow red SIMATIC Manual Collection 6ES7 393-4AA00-0AA0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

Order No.

6ES7 321-7RD00-0AB0

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-2XX00-0AA0

6ES7 392-2XY00-0AA0

10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license

6ES7 998-8XC01-8YE2

5/296

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Ex Digital Modules


Ex digital output modules

Overview
Digital outputs for signals from the Ex field For the connection of intrinsically safe digital equipment from the Ex field 4 DO DC 24 V/10mA or 4 DO DC 15 V/20 mA 4 digital outputs in 4 channel modules (single-channel isolation) Diagnostics and diagnostics alarm programmable Substitute value behavior programmable

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital outputs Number of digital outputs Cable length unshielded, max. Response threshold, typ. 4 200 m Output current with short-circuit protection, min. 10 mA + 10 % 24 V 10 mA; +/-10% 100 Hz 4 200 m Yes; Electronic Output current with short-circuit protection, min. 20.5 mA + 10 % 15 V 20 mA; +/-10% 100 Hz 20-pin 20-pin 160 mA 70 mA 3W 160 mA 70 mA 3W 24 V 24 V 6ES7 3225SD00-0AB0 6ES7 3225RD00-0AB0 Order No. Ex(i) characteristics Max. values of output circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Uo (output no-load voltage), max. Status information/ alarms/diagnostics Diagnoses Diagnostic information readable Short circuit Group error Isolation Isolation, digital outputs Galvanic isolation, digital outputs between the channels, in groups of Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM [EEx ib] IIC Class I, Division 2, Group A, B, C, D T4 Ex-96.D.2093X 230 g [EEx ib] IIC AIS CL.1, DIV 1, GP A, B, C, D; CL.I, DIV 2, GP A, B, C, D T4 Ex-96.D.2102X 230 g Yes 1 Yes 1 Yes Yes Yes Yes Yes Yes 90 nF 70 mA 6.7 milliH 440 mW 25.2 V 500 nF 85 mA 5 milliH 335 mW 15.75 V 6ES7 3225SD00-0AB0 6ES7 3225RD00-0AB0

Short-circuit protection of the output Yes; Electronic

Output voltage Rated value (DC) Output current for signal "1" permissible range for 0 to 60 C, max. Switching frequency with resistive load, max. Load impedance range upper limit 390 ; Two-wire 200 ; Two-wire connection connection

Test number PTB Weights Weight, approx.

Siemens IK PI 2009

5/297

Siemens AG 2008

ET 200M Ex Digital Modules


Ex digital output modules

SIMATIC ET 200 distributed I/Os

Ordering data
Ex digital output modules 4 outputs, isolated, 24 V DC, 10 mA 4 outputs, isolated, 15 V DC, 20 mA Front connectors 20-pin, with screw contacts 1 unit 100 units Front door, elevated design e.g. for 32 channel modules; enables connection of 1.3 mm2/16 AWG wires LK 393 cable guide Mandatory for operation in Ex-hazard areas Labeling strips

Order No. Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 328-0AA00-7AA0 yellow red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates

Order No.

6ES7 322-5SD00-0AB0 6ES7 322-5RD00-0AB0

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

6ES7 393-4AA00-0AA0

6ES7 392-2XX00-0AA0

10 units (spare part), for modules with 20-pin front connector Label cover 10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 6ES7 392-2XY00-0AA0

6ES7 998-8XC01-8YE2

5/298

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Ex Analog Modules


Ex analog input modules

Overview
Analog inputs for signals from the Ex field For the connection of intrinsically safe analog equipment from the Ex field 8 or 4 analog inputs in 4 channel groups (single-channel isolation) Measurement type and range can be selected for each channel Diagnostics and diagnostics alarm programmable Programmable threshold alarm HART-compatible inputs (only 6ES7331-7RD00-0AB0)

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Voltage supply to the transducers present Rated value (DC) No-load voltage (DC) Current consumption from backplane bus DC 5 V, max. from supply voltage L+, max. Power loss, typ. Connection point required front connectors Analog inputs Number of analog inputs 4 8; 8x thermocouples; 4x RTD thermal sensors 200 m; HTC: 50 m 20-pin 20-pin 60 mA 150 mA 3W 0.6 W 120 mA Yes 13 V; at 22 mA 25.2 V 24 V 24 V 6ES7 3317RD00-0AB0 6ES7 3317SF00-0AB0 Order No. Input ranges (rated values), thermoelements Type B Type E Type J Type K Type L Type N Type R Type S Type T Type U Input ranges (rated values), resistance thermometers Ni 100 Pt 100 Pt 200 Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Yes Yes Integration time, parameterizable 16 Bit; 10 to 15 bits + sign Yes; 2.5 to 100 ms 16 Bit; 10 to 15 bits + sign Yes; 2.5 to 100 ms 10 to 400 Hz Sigma Delta Sigma Delta Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 3317RD00-0AB0 6ES7 3317SF00-0AB0

cable length, shielded, max. permissible input current for current input (destruction limit), max. Input ranges (rated values), currents 0 to 20 mA 4 to 20 mA

200 m 40 mA

Interference voltage suppression 10 to 400 Hz for interference frequency f1 in Hz

Siemens IK PI 2009

5/299

Siemens AG 2008

ET 200M Ex Analog Modules


Ex analog input modules

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Encoder Connection of signal encoders for current measurement as 2-wire transducer for current measurement as 4-wire transducer Ex(i) characteristics Max. values of input circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Ri, max. Uo (output no-load voltage), max. Errors/accuracies Operational limit in overall temperature range Current, relative to input area Basic error limit (operational limit at 25 C) Current, relative to input area Resistance-type thermometer, relative to input area Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency Series mode interference 60 db (peak value of interference < rated value of input range), min. common mode voltage, min. Status information/ alarms/diagnostics Diagnoses Diagnostic information readable Overrange Short circuit of the signal encoder cable Isolation Isolation, analog inputs Isolation, analog inputs Permissible potential difference between the inputs (UCM) between inputs and MANA (UCM) Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM [EEx ib] IIC Class I, Division 2, Group A, B, C, D T4 Ex-96.D.2092X 290 g [EEx ib] IIC Class I, Division 2, Group A, B, C, D T4 Ex-96.D.2108X 210 g 60 V DC 60 V DC 60 V DC 30 V DC Yes Yes Yes Yes Yes Yes Yes Yes Yes 130 db 60 db +/- 0,1 % +/- 0,1 % +/- 0,45 % 90 nF 68.5 mA 7.5 milliH 431 mW 50 25.2 V 5.9 V 60 F 28.8 mA 40 milliH 41.4 mW Yes Yes Yes Yes 6ES7 3317RD00-0AB0 6ES7 3317SF00-0AB0

Ordering data
Ex analog input modules 4 inputs, isolated, 0/4 to 20 mA, 15 bit 8/4 inputs, isolated, for thermocouples and Pt100, Pt200, Ni100 Front connectors 20-pin, with screw contacts 1 unit 100 units Front door, elevated design e.g. for 32 channel modules; enables connection of 1.3 mm2/16 AWG wires LK 393 cable guide Mandatory for operation in Ex-hazard areas Labeling strips 10 units (spare part), for modules with 20-pin front connector Label cover 10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates

Order No.

6ES7 331-7RD00-0AB0 6ES7 331-7SF00-0AB0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 328-0AA00-7AA0

6ES7 393-4AA00-0AA0

6ES7 392-2XX00-0AA0

6ES7 392-2XY00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

130 db

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

Wire break in signal encoder cable Yes

6ES7 998-8XC01-8YE2

Test number PTB Weights Weight, approx.

5/300

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Ex Analog Modules


Ex analog output modules

Overview
Analog outputs for signals from the Ex field For the connection of intrinsically safe analog equipment from the Ex field 4 analog outputs in 4 channel modules (single-channel isolation) Diagnostics and diagnostics alarm programmable

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Analog outputs Number of analg outputs cable length, shielded, max. Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Output ranges, current 0 to 20 mA 4 to 20 mA Connection of actuators for current output 2-conductor connection Load impedance (in rated range of output) with current outputs, max. Analog value creation Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Basic conversion time, ms 15 Bit 2.5 ms 500 Yes Yes Yes 4 200 m Yes 70 mA 14 V 20-pin 180 mA 80 mA 4W 24 V 6ES7 332-5RD00-0AB0 Order No. Ex(i) characteristics Max. values of output circuits (per channel) Co (permissible external capacity), max. Io (chort-circuit current), max. Lo (permissible external inductivity), max. Po (power of load), max. Uo (output no-load voltage), max. Errors/accuracies Operational limit in overall temperature range Current, relative to output area Basic error limit (operational limit at 25 C) Current, relative to output area Status information/ alarms/diagnostics Diagnoses Diagnostic information readable Overrange Wire break in acutator cable Group error Isolation Isolation, analog outputs Galvanic isolation, analog outputs Yes Permissible potential difference between outputs and MANA (UCM) between the outputs (UCM) Standards, approvals, certificates Type of protection to EN 50020 (CENELEC) Type of protection to FM Test number PTB Weights Weight, approx. 280 g [EEx ib] IIC Class I, Division 2, Group A, B, C, D T4 Ex-96.D.2026X 60 V DC / 30 V AC 60 V DC/30 V AC Yes Yes Yes Yes +/- 0,2 % +/- 0,55 % 850 nF 70 mA 6.6 milliH 440 mW 14 V 6ES7 332-5RD00-0AB0

Siemens IK PI 2009

5/301

Siemens AG 2008

ET 200M Ex Analog Modules


Ex analog output modules

SIMATIC ET 200 distributed I/Os

Ordering data
Ex analog output module 4 outputs, isolated, 0/4 to 20 mA Front connectors 20-pin, with screw contacts 1 unit 100 units Front door, elevated design e.g. for 32 channel modules; enables connection of 1.3 mm2/16 AWG wires LK 393 cable guide Mandatory for operation in Ex-hazard areas Labeling strips 10 units (spare part), for modules with 20-pin front connector Label cover

Order No. 6ES7 332-5RD00-0AB0 Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 6ES7 328-0AA00-7AA0 petrol light-beige yellow red SIMATIC Manual Collection 6ES7 393-4AA00-0AA0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

Order No.

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-2XX00-0AA0

6ES7 392-2XY00-0AA0

10 units (spare part), for modules with 20-pin front connector S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license

6ES7 998-8XC01-8YE2

5/302

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


Introduction

Overview
Function modules unburden the CPU of work-intensive tasks such as counting, positioning and controlling Module spectrum Counter modules Positioning modules for rapid and creep feed drives Positioning modules for stepper motors Positioning modules for servo motors Positioning and continuous path modules SSI position decoder modules Electronic cam controllers High-speed Boolean processor Control modules
Function modules Counting Positioning of rapid and creep feed drives of stepper motors of servo motors Positioning and path control SSI position detection Electronic cam control High-speed logic operation Controlling FM 351 positioning module FM 353 positioning module FM 354 positioning module FM 357-2 positioning and path control module1) SM 338 POS input modules FM352 electronic cam controller FM 352-5 high-speed Boolean processor FM 355 controller module FM 355-2 temperature controller module Weighing and proportioning electronics
1)

FM 350-1 counter module FM 350-2 counter module

SIWAREX

Not for ET 200M

Siemens IK PI 2009

5/303

Siemens AG 2008

ET 200M Function modules


Introduction

SIMATIC ET 200 distributed I/Os

Overview (continued)
Applicability with ET 200M distributed I/O device Almost all function modules can also be used in the ET 200M distributed I/O device. In doing so, the following details must be observed:
For use behind IM 153-1 For use behind IM 153-2 For use behind IM 153(6ES7 153-1AA03-0XB0) (6ES7 153-2BA02-0XB0) 2 FO (6ES7 153-2BB000XB0) For use behind IM 153-4 PN (6ES7 1534AA00-0XB0) STEP 71)
n n n n n n

Configurable with Module FM 350-1 counter module FM 350-2 counter module FM 351 positioning module FM 352 cam controller Order No. 6ES7 350-1AH03-0AE0 6ES7 350-2AH01-0AE0 6ES7 351-1AH01-0AE0 6ES7 352-1AH02-0AE0 6ES7 352-5AH00-0AE0 6ES7 352-5AH10-0AE0 STEP 71)
n n n n 3) n n3)

GSD2) ----n n

STEP 71)
n n n n n 3)

GSD2) ----n n

STEP 71)
n n n n n 3)

GSD2) ----n n

FM 352-5 high-speed Boolean processor FM 352-5 high-speed Boolean processor FM 353 positioning module FM 354 positioning module FM 355 C controller module FM 355 S controller module FM 355-2 C temperature control module FM 355-2 S temperature control module SM 338 POS input module
n:

n3) n n n n n n n

n3) n n n n n n n

6ES7 353-1AH01-0AE0 -6ES7 354-1AH01-0AE0 -6ES7 355-0VH10-0AE0 6ES7 355-1VH10-0AE0 6ES7 355-2CH00-0AE0 6ES7 355-2SH00-0AE0 6ES7 338-4BC01-0AB0 --n n n

------n

------n

------n

--n n n n n

configurable --: not configurable


Configuration using the Meta-knowledge integrated in STEP 7 (in Hardware Catalog under PROFIBUS DP > ET200M > IM 153-1 / IM 153-2 or PROFINET IO > I/O > ET 200M > IM153-4 PN). Configuration using GSD file (after installation of the GSD file configurable from the Hardware Catalog under PROFIBUS DP > Additional field devices > I/O > ET200M). During configuration on the CP 342-5 as DP master, S5 (IM 308C) as DP master or external masters, the GSD file must be configured. Visible and configurable only with the corresponding configuration package in STEP 7.

1)

2)

3)

Position measurement systems and prefabricated connecting cables for counter and positioning function are offered under SIMODRIVE Sensor and Motion Connect 500. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

5/304

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 350-1 counter module

Overview
One-channel intelligent counter module for simple counting tasks For direct connection of incremental encoders Comparison function with 2 specifiable comparison values Integrated digital outputs to output the response upon reaching the comparison value. Operating modes: - Continuous counting - One-shot counting - Periodic counting Special functions: - Set counter - Latch counter Start/stop counter with gate function Note: Incremental encoders and pre-assembled connecting cables for counting and positioning functions are offered under SIMODRIVE Sensor or Motion Connect 500. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications
Order No. Voltages and currents Aux. voltage 1L+, load voltage 2 L+ Rated value (DC) Permissible range (ripple included) - dynamic, lower limit (DC) - dynamic, upper limit (DC) - static, lower limit (DC) - static, upper limit (DC) non-periodic skip - Duration - Recovery time - Value Current consumption from load voltage 1L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital inputs Number of digital inputs Functions Input voltage for signal "0" for signal "1" Input current for signal "1", typ. Digital outputs Number of digital outputs Short-circuit protection of the output Limitation of inductive shutdown voltage to 2 Yes; clocked electronically 2L+ (-39 V) 9 mA -28.8 to +5 V +11 to +28.8 V 3 1 for gate start, 1 for gate stop, 1 for setting the counter 1x 20-pin 40 mA 160 mA 4.5 W 24 V 6ES7 350-1AH03-0AE0 Order No. Output voltage for signal "0" (DC), max. for signal "1", min. Output current for signal "1" rated value 18.5 V 30.2 V 20.4 V 28.8 V 500 ms 50 s 35 V for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load "0" to "1", max. Encoder supply 5 V encoder supply 5V Output current, max. 24 V encoder supply 24 V Output current, max. Encoder Connectable encoders Incremental encoder (symmetrical) Incremental encoder (asymmetrical) 24 V initiator 24 V directional element Counters Number of counter inputs Counting range, Description Minimum pulse width, adjustable Counter input 5 V Type Terminating resistor Differential input voltage Counter frequency, max. RS 422 220 1.3 V 500 kHz 1 32 bit or +/-31 bit Yes; 2.5 or 25 s Yes; with 2 pulse strings offset by 90 Yes Yes Yes; 1 pulse train, 1 direction level Yes; 1L+ (-3 V) 400 mA Yes; 5.2 V +/-2% 300 mA 300 s 0.5 A 5 mA 0.6 A 3V 2L+ (-1.5 V) 6ES7 350-1AH03-0AE0

Siemens IK PI 2009

5/305

Siemens AG 2008

ET 200M Function modules


FM 350-1 counter module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Counter input 24 V Input voltage, for signal "0" Input voltage, for signal "1" Input current, for signal "1", typ. Counter frequency, max. Minimum pulse width Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels and the backplane bus Isolation, digital outputs between the channels and the backplane bus Yes; Optocoupler Yes; Optocoupler 500 V 6ES7 350-1AH03-0AE0 -28.8 to +5 V +11 to +28.8 V 9 mA 200 kHz 2.5 s Order No. Isolation counter between the channels and the backplane bus Permissible potential difference between different circuits Dimensions Dimensions Width Height Depth Weights Weight, approx. 250 g 40 mm 125 mm 120 mm 75 VDC / 60 VAC Yes; Optocoupler 6ES7 350-1AH03-0AE0

Ordering data
FM 350-1 counter module with 1 channel, max. 500 kHz; for incremental encoder Coding plug - Range card for analog inputs Spare part Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

Order No. 6ES7 350-1AH03-0AE0 Connectable incremental encoders 6FX2 001-2...

Order No. See the A&D Mall under SIMODRIVE Sensors or Motion Connect 500 (see also www.siemens.com/ simatic-technology) 6FX5 002-2CA12-7 7 7 0

6ES7 974-0AA00-0AA0 Signal cable Preassembled for HTL and TTL encoder, without Sub-D connector, UL/DESINA Length code: 0m 100 m 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0 200 m 0m 10 m 20 m 30 m 40 m 50 m 60 m 70 m 80 m 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0 90 m 0m 1m 2m 3m 4m 5m 6m 7m 8m 6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0 9m

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

1 2 3 A B C D E F G H J K A B C D E F G H J K

5/306

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 350-2 counter module

Overview
8-channel intelligent counter module for universal counting and measuring To directly connect 24 V incremental encoders, direction sensors, initiators or NAMUR encoders. Check function with preselectable set points (number depends on mode) Integrated digital outputs to output the response when the setpoint is reached Modes: - Continuous/one-off/periodic counting - Frequency/speed measurement - Cycle duration measurement - Dosing Note: Incremental encoder and prefabricated connecting cables for counter and positioning function are offered under SIMODRIVE Sensor and Motion Connect 500. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications
Order No. Voltages and currents Aux. voltage 1L+, load voltage 2 L+ Rated value (DC) permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital inputs Number of digital inputs Functions Cable length cable length, shielded, max. Input voltage for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. 8 600 m 100 m 50 s 2 mA 9 mA -3 to +5 V 11 to 30.2 V 100 m 8 1 each for gate start/ gate stop 1x 40-pin 150 mA 100 mA 10 W 24 V 28.8 V permissible range, lower limit (DC) 20.4 V 6ES7 350-2AH01-0AE0 Order No. Limitation of inductive shutdown voltage to Output voltage for signal "1", min. Output current for signal "1" rated value Output delay with resistive load "0" to "1", max. Switching frequency with resistive load, max. with inductive load, max. Aggregate current of the outputs (per group) horizontal installation - up to 40 C, max. - up to 60 C, max. all other mounting positions - up to 40 C, max. Encoder supply Output voltage Output current, rated value Short-circuit protection Encoder Connectable encoders Incremental encoder (asymmetrical) 24 V initiator 24 V directional element NAMUR encoder 2-wire BEROS Yes Yes Yes Yes Yes NAMUR-encoder supply: 8.2 V +/-2% 200 mA Yes 4A 2A 2A 500 Hz 0.5 Hz 300 s 0.5 A for signal "0" residual current, max. 0.5 mA L+ (-0.8 V) 6ES7 350-2AH01-0AE0 L+ (-40 V)

Short-circuit protection of the output Yes

Siemens IK PI 2009

5/307

Siemens AG 2008

ET 200M Function modules


FM 350-2 counter module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. NAMUR encoder Number of NAMUR inputs Input signal Input current, for signal "0", max. Input current, for signal "1", min. Input delay, max. Input frequency, max. cable length, shielded, max. Counters Counter input 24 V Number Input voltage, for signal "0" Input voltage, for signal "1" Input current, for signal "0", max.. (permissible quiescent current) 8; 32 bit or +/-31 bit -3 to 5 V 11 to 30.2 V 2 mA 9 mA 50 s 20 kHz 100 m 8 to DIN 19 234 1.2 mA 2.1 mA 50 s 20 kHz 100 m 6ES7 350-2AH01-0AE0 Order No. Status information/ alarms/diagnostics Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Isolation Galvanic isolation, digital inputs between the channels and the backplane bus between the channels and the backplane bus (NAMUR) Isolation, digital outputs between the channels and the backplane bus Isolation counter between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 460 g 80 mm 125 mm 120 mm Yes; and shielding Yes; and shielding Yes; and shielding yes, against backplane bus and shielding Yes; Diagnostic information readable Yes; Parameterizable Yes; parameterizable 6ES7 350-2AH01-0AE0

Input current, for signal "1", typ. Input delay, max., Counter frequency, max. Cable length, max.

5/308

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 350-2 counter module

Ordering data
FM 350-2 counter module With 8 channels, max. 20 kHz; for 24 V incremental encoders and NAMUR encoders; incl. configuration package and electronic documentation on CD Front connector 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

Order No. 6ES7 350-2AH01-0AE0 Signal cable Pre-assembled for HTL and TTL encoder, without Sub-D connector, UL/DESINA Length code: 0m 100 m 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 200 m 0m 10 m 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX10-0AA0 20 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 0m 1m 2m 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0 3m 4m 5m 6m 7m 8m 9m

Order No. 6FX5 002-2CA12-7 7 7 0

1 2 3 A B C D E F G H J K A B C D E F G H J K

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

Siemens IK PI 2009

5/309

Siemens AG 2008

ET 200M Function modules


FM 351 positioning module

SIMATIC ET 200 distributed I/Os

Overview
Two-channel positioning module for rapid-traverse/ creep-speed drives 4 digital outputs per channel for motor control Incremental or synchro-serial position decoding Note: SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring systems and preassembled connecting cables for counting and positioning functions. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications

Order No. Supply voltages Rated value DC 24 V Current consumption Current consumption, max. Connection point required front connectors Digital inputs Number of digital inputs Functions

6ES7 351-1AH01-0AE0

Order No. 24 V encoder supply 24 V

6ES7 351-1AH01-0AE0 Yes 400 mA; per channel 100 m

Yes 350 mA 1x 20-pin 8 Reference cams, reversing cams, flying actual value setting, start/stop positioning 24 V -3 to +5 V 11 to 30 V

Output current, max. Cable length, max. Encoder Connectable encoders Incremental encoder (symmetrical) Incremental encoder (asymmetrical) Absolute encoder (SSI) 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Encoder signals, incremental encoder (symmetrical) Trace mark signals Zero mark signal Input signal

Yes Yes Yes Yes 2 mA; on signal "0", max. 2 mA; on signal "1", max. 6 mA

Input voltage Rated value, DC for signal "0" for signal "1" Input current for 2-wire BERO - for signal "0", typ. - for signal "1", typ. Digital outputs Number of digital outputs Functions 8 Rapid traverse, creep, run right, run left 2 mA 6 mA

A, notA, B, notB N, notN 5 V difference signal (phys. RS 422) 0.5 MHz

Input frequency, max. Encoder signals, incremental encoder (asymmetrical) Trace mark signals Zero mark signal Input voltage Input frequency, max.

A, B N 24 V 50 kHz; 50 kHz for 25 m cable length; 25 kHz for 100 m cable length

Short-circuit protection of the output Yes Output voltage Rated value (DC) for signal "1", min. Output current for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Encoder supply 5 V encoder supply 5V Output current, max. Cable length, max. Yes 350 mA 32 m 5 mA; with UPmax 600 mA; with UPmax 24 V UP - 0.8 V

Encoder signals, absolute encoder (SSI) Input signal Data signal Clock signal Telegram length Clock frequency, max. Gray code cable length, shielded, max. 5 V difference signal (phys. RS 422) DATA, notDATA CL, notCL 13 or 25 bit 1 MHz yes 300 m; at max. 125 kHz

for signal "0" residual current, max. 0.5 mA

5/310

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 351 positioning module

Technical specifications (continued)


Order No. Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation, digital outputs Galvanic isolation, digital outputs Dimensions Dimensions Width Height Depth Weights Weight, approx. 550 g Order No. 6ES7 351-1AH01-0AE0 80 mm 125 mm 120 mm Yes Yes 6ES7 351-1AH01-0AE0

Ordering data
Signal cables Pre-assembled for HTL encoder, UL/DESINA Pre-assembled for SSI absolute encoder, UL/DESINA Pre-assembled for TTL encoder 6FX2001-1, UL/DESINA Pre-assembled for TTL encoder 24 V, UL/DESINA Not crimped Module end crimped, connector case supplied Motor end crimped, connector case supplied 0m 100 m 200 m

Order No. 6FX5 0 7 2-2AL00- 7 7 7 7 6FX5 0 7 2-2CC11- 7 7 7 7

6FX5 0 7 2-2CD01- 7 7 7 7

6FX5 0 7 2-2CD24- 7 7 7 7

0 1 4 1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8

Ordering data
FM 351 positioning module for rapid traverse and creep speed drives Sub-D connector 15-pin, male Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) Slot number label S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

6ES5 750-2AA21

0m 10 m 20 m 30 m

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

40 m 50 m 60 m 70 m 80 m 90 m 0m 1m 2m 3m 4m 5m 6m 7m 8m 0m

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0 6ES7 912-0AA00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70

0,0 m 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m

6ES7 390-5AA00-0AA0

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

Siemens IK PI 2009

5/311

Siemens AG 2008

ET 200M Function modules


FM 352 cam controller

SIMATIC ET 200 distributed I/Os

Overview
Extremely high-speed electronic cam controller Low-cost alternative to mechanical cam controllers 32 cam tracks, 13 onboard digital outputs for direct output of actions Incremental or synchro-serial position decoding Note: SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring systems and preassembled connecting cables for counting and positioning functions. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications

Order No. Supply voltages Rated value DC 24 V Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Connection point required front connectors Digital inputs Number of digital inputs Functions

6ES7 352-1AH02-0AE0

Order No. Encoder supply 5 V encoder supply

6ES7 352-1AH02-0AE0

Yes 200 mA 100 mA 1 x 20-pin 4 Reference point switch, flying actual value setting/length measurement, brake release, enable track output no. 3 24 V -30 to 5 V 11 to 30 V

5V Output current, max. Cable length, max. 24 V encoder supply 24 V Output current, max. Cable length, max. Encoder Connectable encoders Incremental encoder (symmetrical) Incremental encoder (asymmetrical) Absolute encoder (SSI) 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Encoder signals, incremental encoder (symmetrical) Trace mark signals

Yes 300 mA 32 m Yes 300 mA 100 m

Yes Yes Yes Yes 2 mA

Input voltage Rated value, DC for signal "0" for signal "1" Input current for 2-wire BERO - for signal "0", typ. - for signal "1", typ. Digital outputs Number of digital outputs Functions Output voltage Rated value (DC) for signal "1", min. Output current for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. 5 mA 600 mA; with UPmax 24 V UP - 0.8 V 13 Cam track 2 mA 7 mA

A, notA, B, notB N, notN 5 V diff. signal (phys. RS 422) 1 MHz

Zero mark signal Input signal Input frequency, max. Encoder signals, incremental encoder (asymmetrical) Trace mark signals Zero mark signal Input voltage Input frequency, max.

A, B N 24 V 50 kHz; 50 kHz for 25 m cable length, 25 kHz for 100 m cable length

Short-circuit protection of the output Yes

Encoder signals, absolute encoder (SSI) Data signal Clock signal Telegram length Clock frequency, max. Gray code cable length, shielded, max. DATA, notDATA CL, notCL 13 or 25 bit 1 MHz yes 320 m; at max. 125 kHz

for signal "0" residual current, max. 0.5 mA

5/312

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 352 cam controller

Technical specifications (continued)


Order No. Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation, digital outputs Galvanic isolation, digital outputs Dimensions Dimensions Width Height Depth Weights Weight, approx. 550 g Order No. 6ES7 352-1AH02-0AE0 6ES5 750-2AA21 80 mm 125 mm 120 mm No No 6ES7 352-1AH02-0AE0

Ordering data
Signal cable Pre-assembled for HTL encoder, UL/DESINA Pre-assembled for SSI absolute encoder, UL/DESINA Pre-assembled for TTL encoder 6FX2001-1, UL/DESINA Pre-assembled for TTL encoder 24 V, UL/DESINA Not crimped Module end crimped, connector case supplied Motor end crimped, connector case supplied 0m 100 m 200 m 0m 10 m 20 m

Order No. 6FX5 0 7 2-2AL00- 7 7 7 7 6FX5 0 7 2-2CC11- 7 7 7 7

6FX5 0 7 2-2CD01- 7 7 7 7

6FX5 0 7 2-2CD24- 7 7 7 7

0 1 4 1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8

Ordering data
FM 352 electronic cam controller Sub-D connector 15-pin, male Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

30 m 40 m 50 m 60 m 70 m 80 m 90 m 0m 1m 2m 3m 4m 5m 6m 7m

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0

8m 0m 0.0 m 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

Siemens IK PI 2009

5/313

Siemens AG 2008

ET 200M Function modules


Overview

SIMATIC ET 200 distributed I/Os

FM 352-5 high-speed Boolean processor

The FM 352-5 High-speed Boolean processor offers an extremely fast binary control and some of the quickest switching procedures ever possible (cycle duration: 1 s) Programming with LAD or FBD is possible The instruction set available includes bit instructions (instruction subset of STEP 7), timers, counters, frequency dividers, frequency generators, and shift registers 12 integrated DI/8 integrated DO 2 versions: Current sinking or current sourcing digital outputs 1 channel for connecting a 24 V incremental encoder, a 5 V incremental encoder (RS422) or a serial interface absolute encoder A micro memory card is required for operation of the FM 352-5 Note: SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring systems and preassembled connecting cables for counting and positioning functions. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications
Order No. Supply voltages Rated value DC 24 V Voltages and currents Load voltage L+ Rated value (DC) reverse polarity protection permissible range, lower limit (DC) permissible range, upper limit (DC) Current consumption from load voltage1L+, max. from load voltage 2L+ (without load), max. from load voltage 3L+ (with encoder), max. from load voltage 3L+ (without encoder), max. from backplane bus DC 5 V, max. Power loss, typ. Memory Type of storage Memory Card, RAM 128 KByte; 128 KByte; required for required for operation, MMC operation, MMC PLC interface: 5 ms (2.6 ms type) 1x 40-pin PLC interface: 5 ms (2.6 ms type) 1x 40-pin Minimum pulse width for program reactions 150 mA; typ. 60 mA 200 mA; typ. 60 mA, DI/DO supply 600 mA; typ. 80 mA plus encoder supply 200 mA; typ. 80 mA 100 mA; typically 6.5 W 150 mA; typ. 60 mA 200 mA; typ. 60 mA, DI/DO supply 600 mA; typ. 80 mA plus encoder supply 200 mA; typ. 80 mA 100 mA; typically 6.5 W Cable length unshielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) Input frequency (with 0.1 ms delay), max. Programmable digital filter delay 200 kHz None, 5 s, 10 s, 15 s, 20 s, 50 s, 1.5 ms 1 s, 5 s, 10 s, 15 s, 20 s, 50 s, 1.6 ms 200 kHz None, 5 s, 10 s, 15 s, 20 s, 50 s, 1.5 ms 1 s, 5 s, 10 s, 15 s, 20 s, 50 s, 1.6 ms 1.5 mA 3.8 mA 1.5 mA 3.8 mA 24 V -30 to +5 V 11 to 30 V 24 V -30 to +5 V 11 to 30 V 24 V Yes 20.4 V 28.8 V 24 V Yes 20.4 V 28.8 V Cable length cable length, shielded, max. 600 m; shielded cable recommended if filtering set in 1.6 ms frame. 100 m 600 m; shielded cable recommended if filtering set in 1.6 ms frame. 100 m Yes Yes 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0 Order No. CPU/programming Program cycle time (scan) Digital inputs Number of digital inputs 8; standard and up to 12 at 24 V DC encoder inputs as digital inputs 8; standard and up to 12 at 24 V DC encoder inputs as digital inputs 1 s 1 s 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0

interfaces Updating time

Connection point required front connectors

for standard inputs - at "0" to "1", max.

3 s; typ. 1.5 s 3 s; typ. 1.5 s

5/314

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules

FM 352-5 high-speed Boolean processor

Technical specifications (continued)


Order No. Digital outputs Number of digital outputs M-switching P-switching cable length, shielded, max. Cable length unshielded, max. Short-circuit protection of the output 600 m 100 m Yes; Overvoltage protection, thermal protection 1.7 to 3.5 A 2M +45 V typ, (40 to 55 V); comment: no protection against inductive kickback >55 mJ 5W No 24 V 28.8 V 0.5 V 0.5 A; at 60 C 5 mA 600 mA 8 Yes Yes 600 m 100 m Yes; Overvoltage protection, thermal protection 1.7 to 3.5 A 2M +45 V typ, (40 to 55 V); comment: no protection against inductive kickback >55 mJ 5W No 24 V 28.8 V 0.5 V 0.5 A; at 60 C 5 mA 600 mA 1 mA 1 s; 0.6 s 50 mA / 1.0 s 0.5 A 1.5 s; 1.7 s 50 mA / 1.5 s 0.5 A Yes; 2 Input frequency, max. 100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A 2 Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes 10 Hz 100 kHz; 20 kHz at 0.5 A; 100 kHz at 0.25 A 2 Hz; 2 Hz at 0.5 A with external commutator diodes; 0.5 Hz at 0.5 A without external commutator diodes 10 Hz cable length, shielded, max. Output current, max. Encoder Connectable encoders Incremental encoder (symmetrical) Incremental encoder (asymmetrical) Absolute encoder (SSI) 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Encoder signals, incremental encoder (symmetrical) Trace mark signals Zero mark signal Input signal Yes; 2 A, notA, B, notB A, notA, B, notB N, notN 5 V difference signal (phys. RS 422) 1 MHz 100 m; Cable length, RS-422 (5V) incremental encoders, Siemens type 6FX201-2, 5 V supply: 500 kHz, 32 meters, shielded, max.; cable length, RS-422 (5V) incremental encoders, Siemens type 6FX201-2, 24 V supply: 500 kHz, 100 meters, shielded, max. N, notN 5 V difference signal (phys. RS 422) 1 MHz 100 m; Cable length, RS-422 (5V) incremental encoders, Siemens type 6FX201-2, 5 V supply: 500 kHz, 32 meters, shielded, max.; cable length, RS-422 (5V) incremental encoders, Siemens type 6FX201-2, 24 V supply: 500 kHz, 100 meters, shielded, max. Yes Yes Yes Yes; typ. 1 A 1.5 mA Yes Yes Yes Yes; typ. 1 A 1.5 mA 8 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0 Order No. Encoder supply 5 V encoder supply 5V Short-circuit protection Yes Yes; Electronic overload protection; no protection on applying a normal or counter voltage. 250 mA Yes Yes; Overvoltage and overheating protection if overloaded; diagnostics if output reaches temperature limit; no protection on applying a normal or counter voltage 400 mA Yes Yes; Electronic overload protection; no protection on applying a normal or counter voltage. 250 mA Yes Yes; Overvoltage and overheating protection if overloaded; diagnostics if output reaches temperature limit; no protection on applying a normal or counter voltage 400 mA 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0

Output current, max. 24 V encoder supply 24 V Short-circuit protection

Response threshold, typ. Limitation of inductive shutdown voltage to

Lamp load, max. Controlling a digital input Output voltage Rated value (DC) for signal "0" (DC), max. for signal "1" (DC), max. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. Output delay with resistive load "0" to "1", max.

for signal "0" residual current, max. 1 mA 1 s; 0.6 s 50 mA / 1.0 s 0.5 A 1.5 s; 1.7 s 50 mA / 1.5 s 0.5 A

"1" to "0", max.

Parallel switching of 2 outputs for increased power Switching frequency with resistive load, max.

with inductive load, max.

on lamp load, max.

Siemens IK PI 2009

5/315

Siemens AG 2008

ET 200M Function modules


Technical specifications (continued)
Order No. Encoder signals, incremental encoder (asymmetrical) Trace mark signals Zero mark signal Input voltage Input frequency, max. cable length, shielded, max. A, B N 24 V 200 kHz 6ES7 3525AH00-0AE0

SIMATIC ET 200 distributed I/Os

FM 352-5 high-speed Boolean processor

6ES7 3525AH10-0AE0

Order No. Counters Counting range, Description

6ES7 3525AH00-0AE0 Counting range (16-bit counters): 32,768 to 32,767 (userspecific within this range); counting range (32-bit counters): 2,147,483,648 to 2,147,483,647 (user-specific within this range) -2.14748E9 2.14748E9 Yes Yes Yes

6ES7 3525AH10-0AE0 Counting range (16-bit counters): 32,768 to 32,767 (userspecific within this range); counting range (32-bit counters): 2,147,483,648 to 2,147,483,647 (user-specific within this range) -2.14748E9 2.14748E9 Yes Yes Yes

A, B N 24 V 200 kHz 50 m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, 50 m shielded, max.

50 m; Cable length, HTL incremental encoder, Siemens, type 6FX2001-4: 50 kHz, 25 m shielded, max., 25 kHz, 50 m shielded, max.

Counting range, lower limit Counting range, upper limit Counting mode Counting mode, individual Counting mode, continuous Counting mode, periodic Status information/ alarms/diagnostics Alarms Diagnostic alarm

Encoder signals, absolute encoder (SSI)

Data signal Clock signal Telegram length Clock frequency, max.

DATA, notDATA CK, notCK 13 or 25 bit 1 MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz 320 m; Cable length, RS-422 SSI absolute encoders, Siemens type 6FX201-5, 24 V supply: 125 kHz, 320 meters shielded, max.; 250 kHz, 160 meters shielded, max.; 500 kHz, 60 meters shielded, max.; 1 MHz, 20 meters shielded, max. settable: 16/32/48/64 s Yes; one or two stations Yes; 25 bit message frame Yes Yes 5 V input to 24 V output, 0 filter: 1 to 4 s (typ.); 24 V input to 24 V output, 0 filter: 2 to 6 s (typ.)

DATA, notDATA CK, notCK 13 or 25 bit 1 MHz; 125 kHz, 250 kHz, 500 kHz or 1 MHz 320 m; Cable length, RS-422 SSI absolute encoders, Siemens type 6FX201-5, 24 V supply: 125 kHz, 320 meters shielded, max.; 250 kHz, 160 meters shielded, max.; 500 kHz, 60 meters shielded, max.; 1 MHz, 20 meters shielded, max. settable: 16/32/48/64 s Yes; one or two stations Yes; 25 bit message frame Yes Yes 5 V input to 24 V output, 0 filter: 1 to 4 s (typ.); 24 V input to 24 V output, 0 filter: 2 to 6 s (typ.)

cable length, shielded, max.

Yes; 1L, 2L, 3L missing; MMC error; output overload (8); encoder supply overload; differential wire break; parameterization errror; SSI message frame overflow Yes; 8 available; for generation by user program

Yes; 1L, 2L, 3L missing; MMC error; output overload (8); encoder supply overload; differential wire break; parameterization errror; SSI message frame overflow Yes; 8 available; for generation by user program Yes Yes Yes Yes; 75 V DC / 60 V AC Yes (75 V DC, 60 V AC) Yes (75 V DC, 60 V AC) Yes; Yes CPU, E/A and sensor units are separated

Process alarm

Diagnoses Wire break in signal encoder cable Yes Overflow/underflow missing load voltage Isolation between 1L and 2L and 3L between digital I/O & 2L and encoder I/O & 3L between backplane bus and digital & encoder I/O & 1L & 2L & 3L Galvanic isolation, digital inputs galvanic isolation, digital inputs Yes; Yes CPU, E/A and sensor units are separated Yes; 75 V DC / 60 V AC Yes (75 V DC, 60 V AC) Yes (75 V DC, 60 V AC) Yes Yes

Monoflop time Listening mode Multiturn Encoder signal evaluation Counting direction, forward Counting direction, backward Reaction times Input and output reaction timet

5/316

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules

FM 352-5 high-speed Boolean processor

Technical specifications (continued)


Order No. Dimensions Dimensions Width Height Depth 80 mm 125 mm 120 mm 80 mm 125 mm 120 mm 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0 Order No. Weights Weight, approx. 434 g; Module weight: approx. 434 g (with 1L connection and without I/O connection or MMC); shipping weight: approx. 500 g (with bus and 1L connection and without I/O connection or MMC) Order No. Signal cables 6ES7 352-5AH00-0AE0 6ES7 352-5AH10-0AE0 To HTL and TTL encoders, preassembled, without Sub-D connector To SSI absolute encoders 6FX2 001-5, preassembled, without Sub-D connector Length code: 0m 100 m 200 m 0m 6ES7 392-1AM00-0AA0 6ES7 392-1AM00-1AB0 10 m 20 m 30 m 40 m 6ES7 392-1BM01-0AA0 6ES7 392-1BM01-1AB0 6ES7 392-1CM00-0AA0 50 m 60 m 70 m 80 m 90 m 0m 1m 2m 3m 4m 5m 6m 7m 8m 9m 0.0 m 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m 1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8 6FX5 002-2CA12- 7 7 7 0 6FX5 002-2CC12- 7 7 7 7 434 g; Module weight: approx. 434 g (with 1L connection and without I/O connection or MMC); shipping weight: approx. 500 g (with bus and 1L connection and without I/O connection or MMC) 6ES7 3525AH00-0AE0 6ES7 3525AH10-0AE0

Ordering data
FM 352-5 high-speed Boolean processor with current sinking digital outputs with current sourcing digital outputs Micro Memory Card 128 KB 512 KB 2 MB Front connectors 40-pin, with screw contacts 1 unit 100 units 40-pin with spring-loaded contacts 1 unit 100 units 40-pin, with FastConnect 1 unit

Order No.

6ES7 953-8LG11-0AA0 6ES7 953-8LJ20-0AA0 6ES7 953-8LL20-0AA0

Siemens IK PI 2009

5/317

Siemens AG 2008

ET 200M Function modules


FM 353 positioning module

SIMATIC ET 200 distributed I/Os

Overview
Positioning module for stepper motors in machines with high clock pulse rates Can be used for point-to-point positioning tasks and for complex traversing patterns

Technical specifications

Order No. Supply voltages Rated value DC 24 V permissible range, upper limit (DC) Current consumption Current consumption, max. Connection point required front connectors Digital inputs Number of digital inputs Functions

6ES7 353-1AH01-0AE0

Order No. Output voltage Rated value (DC)

6ES7 353-1AH01-0AE0 24 V UP - 3 V 0.6 A; with UPmax

Yes 28.8 V

for signal "1", min. Output current for signal "1" permissible range for 0 to 55 C, max. Drive interface Signal input I Function Signal output I Output ready signal Type Function Differential output voltage, min.

permissible range, lower limit (DC) 20.4 V

for signal "0" residual current, max. 2 mA 300 mA 1x 20-pin 4; (+ 1 input for message signal) Reference cams, flying actual value setting, flying measurement, start/stop positioning, external block change 24 V -3 to +5 V 11 to 30 V 2 mA 6 mA; 6 to 15 mA 4 Position reached: stop, axis travels forward, axis travels back, change M-function M97, change M-function M98, start enable, direct output via data record

"Power section ready"

5 V difference signal (phys. RS 422) Direction , enable, clock pulse, current control 2 V; RL = 100 Ohm 1 V; Io = 20 mA 3.7 V; Io = -20 mA 35 m

Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Digital outputs Number of digital outputs Functions

Differential output voltage for signal "0", max. Differential output voltage, for signal "1", min. Cable length, max. Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation, digital outputs Galvanic isolation, digital outputs Dimensions Dimensions Width Height Depth Weights Weight, approx.

No No

80 mm 125 mm 118 mm 500 g

Short-circuit protection of the output Yes

5/318

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 353 positioning module

Ordering data
FM 353 positioning module For stepper motors; incl. configuration package on CD-ROM (Ge, En, Fr, It) comprising FM 353 manual, electronic Standard function blocks (STEP 7 interface software) Screen form-based configuration software for FM 353 Standard interactive screen forms for OP7/OP17 FM 353 manual German English French Italian Edit FM Program editor for editing, loading and saving NC programs with the standard programming device/PC; German/English, on CD-ROM Connecting cables and encoders Sub-D connector 15-pin, socket Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

Order No. 6ES7 353-1AH01-0AE0 Connecting cables To stepper motor power section Not crimped Module end crimped, connector case supplied Motor end crimped, connector case supplied 0m 100 m 6ES7 353-1AH01-8AG0 6ES7 353-1AH01-8BG0 6ES7 353-1AH01-8CG0 6ES7 353-1AH01-8EG0 6FC5 263-0AA03-0AB0 200 m 0m 10 m 20 m 30 m 40 m 50 m 60 m 70 m See Catalog NC 60, CA 01 or in the A&D Mall 6ES5 750-2AB21 80 m 90 m 0m 1m 2m 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 3m 4m 5m 6m 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0 7m 8m 0m 0.0 m 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0 0.8 m

Order No. 6FX8 0 7 2-3AC02- 7 7 7 7 0 1 4 1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

Siemens IK PI 2009

5/319

Siemens AG 2008

ET 200M Function modules


FM 354 positioning module

SIMATIC ET 200 distributed I/Os

Overview
Positioning module for servo motors in machines with high clock pulse rates Can be used for point-to-point positioning tasks and for complex traversing patterns Note: SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring systems and preassembled connecting cables for counting and positioning functions. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Technical specifications

Order No. Supply voltages Rated value DC 24 V Current consumption Current consumption, max. Connection point required front connectors Digital inputs Number of digital inputs Functions

6ES7 354-1AH01-0AE0

Order No. Encoder supply 5 V encoder supply

6ES7 354-1AH01-0AE0

Yes 350 mA 1x 20-pin 4 Reference cams, flying actual value setting, flying measurement, start/stop positioning, external block change 24 V -3 to +5 V 11 to 30 V 2 mA 6 mA; 6 to 15 mA 4 Position reached: stop, axis travels forward, axis travels back, change M-function M97, change M-function M98, start enable, direct output via data record

5V Output current, max. Cable length, max. 24 V encoder supply 24 V Output current, max. Cable length, max. Encoder Connectable encoders Incremental encoder (symmetrical) Absolute encoder (SSI) Encoder signals, incremental encoder (symmetrical) Trace mark signals Zero mark signal Input signal Input frequency, max. Encoder signals, absolute encoder (SSI) Input signal Data signal Clock signal Telegram length Clock frequency, max. cable length, shielded, max.

Yes 220 mA 35 m Yes 300 mA 100 m

Yes Yes

Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Digital outputs Number of digital outputs Functions

A, notA, B, notB N, notN 5 V difference signal (phys. RS 422) 1 MHz

5 V difference signal (phys. RS 422) DATA, notDATA CL, notCL 13, 21 or 25 bit 1.25 Mbit/s 100 m; 10 m at 1.25 Mbit/s, 100 m at max. 125 kbit/s

Short-circuit protection of the output Yes Output voltage Rated value (DC) for signal "1", min. Output current for signal "1" permissible range for 0 to 55 C, max. 0.6 A; with UPmax 24 V UP - 3 V

for signal "0" residual current, max. 2 mA

5/320

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 354 positioning module

Technical specifications (continued)


Order No. Drive interface Signal input I Type Function Input voltage, rated value (DC) Input voltage, for signal "0" Input voltage, for signal "1" Input current, for signal "1" Signal output II Type Function Load Signal output III Type Function Output voltage Output current Cable length, max. Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs Isolation, digital outputs Galvanic isolation, digital outputs Dimensions Dimensions Width Height Depth Weights Weight, approx. 550 g 80 mm 125 mm 118 mm No No Analog output Setpoint output for drive -10 to +10 V -3 to +3 mA 35 m Output closed-loop controller enable (contact) Drive disconnection for operation via contact relay 1 A/50 V/30 VA DC Input loop controller message, isolated (optocoupler) "Drive ready" 24 V -3 to 5 V 15 to 30 V 2 to 6 mA 6ES7 354-1AH01-0AE0

Ordering data
FM 354 positioning module for servo motors, incl. configuration package on CD-ROM (Ge, En, Fr, It) comprising FM 354 manual, electronic Standard function blocks (STEP 7 interface software) Screen form-based configuration software for FM 354 Standard interactive screen forms for OP7/OP17 FM 354 manual German English French Italian Edit FM Program editor for editing, loading and saving NC programs with the standard programming device/PC; German/English, on CD-ROM

Order No. 6ES7 354-1AH01-0AE0

6ES7 354-1AH01-8AG0 6ES7 354-1AH01-8BG0 6ES7 354-1AH01-8CG0 6ES7 354-1AH01-8EG0 6FC5 263-0AA03-0AB0

Siemens IK PI 2009

5/321

Siemens AG 2008

ET 200M Function modules


FM 354 positioning module

SIMATIC ET 200 distributed I/Os

Ordering data
Connecting cables To SSI absolute encoders 6FX2 001-5, preassembled To incremental encoders 6FX2 001-1, preassembled For 24 V incremental encoders, preassembled To ROD 320 built-in encoders, preassembled To SIMODRIVE 611A, preassembled To SIMODRIVE 611U, preassembled To SSI absolute encoders 6FX2 001-5, preassembled, without Sub-D connector To SSI absolute encoders 6FX2 001-5, preassembled, suitable for trailing To incremental encoders 6FX2 001-2, preassembled, suitable for trailing To ROD 320 built-in encoders, preassembled, suitable for trailing To SIMODRIVE 611A, preassembled, suitable for trailing To SIMODRIVE 611U, preassembled, suitable for trailing, 1 free end To SIMODRIVE 611A, preassembled, suitable for trailing, free ends Not crimped Module end crimped, connector case supplied Motor end crimped, connector case supplied 0m 100 m 200 m 0m 10 m 20 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 0m 1m 2m 3m 4m 5m 6m 7m 8m 0m 0.0 m 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m

Order No. Encoders 6FX5 0 7 2-2CC11- 7 7 7 7 6FX5 0 7 2-2CD01- 7 7 7 7 6FX5 0 7 2-2CD24- 7 7 7 7 6FX5 0 7 2-2CE02- 7 7 7 7 6FX5 0 7 2-2CJ00- 7 7 7 7 6FX5 0 7 2-2CJ10- 7 7 7 7 6FX5 0 7 2-2CC12- 7 7 7 7 6FX8 0 7 2-2CC11- 7 7 7 7 6FX8 0 7 2-2CD01- 7 7 7 7 6FX8 0 7 2-2CE02- 7 7 7 7 6FX8 0 7 2-2CJ00- 7 7 7 7 6FX8 0 7 2-2CJ10- 7 7 7 7 6FX8 0 7 2-3AB01- 7 7 7 7 0 1 4 1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8 Sub-D connector 15-pin, male 9-pin, female Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

Order No. See Catalog NC 60, CA 01 or in the A&D Mall 6ES5 750-2AA21 6ES5 750-2AB11

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

5/322

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 355 controller module

Overview
4-channel closed-loop control module for universal closedloop control tasks Used for temperature, pressure, flowrate and fill-level control loops User-friendly online self-optimization for temperature controls Preprogrammed controller structures 2 control algorithms 2 versions: - FM 355 C as continuous-action controller; - FM 355 S as step or pulse controller With 4 analog outputs (FM 355 C) or 8 digital outputs (FM 355 S) for direct control of the most common types of actuator Continued operation of the control loop is possible even after a CPU stop or failure

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, max. Power loss, typ. Connection point required front connectors Digital inputs Number of digital inputs Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Short-circuit protection of the output Limitation of inductive shutdown voltage to 8 1,000 m 600 m Yes; Electronic L+ (-1.5 V) 7 mA 7 mA 24 V -3 to +5 V 13 to 30 V 24 V -3 to +5 V 13 to 30 V 1,000 m 600 m Yes 1,000 m 600 m Yes 8 8 2x 20-pin 2x 20-pin 310 mA; typ. 260 mA 75 mA; typ. 50 mA 7.8 W 6.5 W 270 mA; typ. 220 mA 75 mA; typ. 50 mA 6.9 W 5.5 W 24 V 28.8 V 24 V 20.4 V 28.8 V permissible range, lower limit (DC) 20.4 V 6ES7 3550VH10-0AE0 6ES7 3551VH10-0AE0 Order No. Lamp load, max. Controlling a digital input Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. for signal "0" residual current, max. Parallel switching of 2 outputs for logic links Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) up to 60 C, max. Load impedance range lower limit upper limit Analog inputs Number of analog inputs cable length, shielded, max. 4 200 m; 50 m at 80 mV and thermocouples 4 200 m; 50 m at 80 mV and thermocouples 30 V 40 mA 240 4 k 400 mA 100 Hz 0.5 Hz 100 Hz Yes 100 mA 5 mA 150 mA 0.5 mA L+ (-2.5 V) 6ES7 3550VH10-0AE0 6ES7 3551VH10-0AE0 5W Yes

permissible input frequency for volt- 30 V age input (destruction limit), max. permissible input current for current input (destruction limit), max. Input ranges (rated values), voltages 0 to +10 V -1.75 to +11.75 V -80 mV to +80 mV Yes Yes Yes 40 mA

Yes Yes Yes

Siemens IK PI 2009

5/323

Siemens AG 2008

ET 200M Function modules


FM 355 controller module

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Order No. Input ranges (rated values), currents 0 to 20 mA 0 to 23.5 mA -3.5 to +23.5 mA 4 to 20 mA Input ranges (rated values), thermoelements Type B Type J Type K Type R Type S Input ranges (rated values), resistance thermometers Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 3550VH10-0AE0 6ES7 3551VH10-0AE0 Order No. Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Conversion time (per channel) Yes Yes Type B, J, K, R, S Pt100 (standard) Yes Yes Yes Yes Type B, J, K, R, S Pt100 (standard) Yes Yes Settling time for resistive load for capacitive load for inductive load Encoder Connection of signal encoders for voltage measurement 4 200 m; 50m at 80 mV and thermocouples Yes 25 mA 18 V for current measurement as 4-wire transducer Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Errors/accuracies Linearity error (relative to input area) +/- 0,05 % Temperature error (relative to input areas) Linearity error (relative to output area) Temperature error (relative to output area) Operational limit in overall temperature range Voltage, relative to input area Current, relative to input area Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area +/- 0,6 %; +/-0.6 to +/-1% +/- 0,6 %; +/-0.6 to +/-1% +/- 0,6 %; +/-0.6 to +/-1% +/- 0,5 % +/- 0,6 % +/- 0,6 %; +/-0.6 to +/-1% +/- 0,6 %; +/-0.6 to +/-1% +/- 0,6 %; +/-0.6 to +/-1% +/- 0,005 %/K +/- 0,05 % +/- 0,02 %/K +/- 0,05 % +/- 0,005 %/K Yes 1.5 mA Yes 1.5 mA Yes Yes Yes Yes 0.2 ms 3.3 ms 0.5 ms 0.1 ms 3.3 ms 0.5 ms 14 Bit; 12 or 14 bit, parameterizable 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 and 60 Hz 14 Bit; 12 or 14 bit, parameterizable 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 and 60 Hz integrating integrating 1 k 1 F 500 1 milliH 6ES7 3550VH10-0AE0 6ES7 3551VH10-0AE0

Pt 100 Characteristic curve linearization programmable for thermoelements for thermoresistor Temperature compensation external temperature compensation with Pt100 internal temperature compensation Analog outputs Number of analg outputs cable length, shielded, max.

Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Output ranges, voltage 0 to 10 V -10 to +10 V Output ranges, current 0 to 20 mA 4 to 20 mA Connection of actuators for voltage output 2-conductor connection for current output 2-conductor connection

Yes Yes Yes Yes Yes Yes

5/324

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


FM 355 controller module

Technical specifications (continued)


Order No. Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,4 %; 80 mV: +/-0.6%; 250 to 1000 mV: +/-0.4%; 2.5 to 10 V: +/-0.6%; 3.2 to 20 mA: +/-0.5% +/- 0,4 %; +/-0.4 to +/-0.6% +/- 0,4 %; +/-0.4 to +/-0.6% +/- 0,3 % +/- 0,5 % +/- 0,4 %; 80 mV: +/-0.6%; 250 to 1000 mV: +/-0.4%; 2.5 to 10 V: +/-0.6%; 3.2 to 20 mA: +/-0.5% +/- 0,4 %; +/-0.4 to +/-0.6% +/- 0,4 %; +/-0.4 to +/-0.6% 6ES7 3550VH10-0AE0 6ES7 3551VH10-0AE0

Ordering data
FM 355 C controller module with 4 analog outputs for 4 continuous-action controllers FM 355 S controller module with 8 digital outputs for 4 step or pulse controllers Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Bus connectors 1 unit (spare part) Labeling strips 40 db 10 units (spare part) S7 SmartLabel V3.0 70 db Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each

Order No. 6ES7 355-0VH10-0AE0

6ES7 355-1VH10-0AE0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

Current, relative to input area

Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0

Series mode interference 40 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. Control technology Number of closed loop controllers Status information/ alarms/diagnostics Substitute values connectable Isolation Isolation checked with Isolation Isolation, controller between the channels between the channels and the backplane bus Permissible potential difference between inputs and MANA (UCM) 2.5 V DC No Yes; Optocoupler 500 VDC 4 70 db

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0

Yes; Parameter- Yes; Parameterizable izable 500 VDC

No Yes; Optocoupler 2.5 V DC 75 V DC / 60 V AC

Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter 6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

between M internally and the inputs 75 V DC / 60 V AC Dimensions Dimensions Width Height Depth Weights Weight, approx. 470 g 80 mm 125 mm 120 mm

80 mm 125 mm 120 mm 470 g

Siemens IK PI 2009

5/325

Siemens AG 2008

ET 200M Function modules


Overview

SIMATIC ET 200 distributed I/Os

FM 355-2 temperature controller module

4-channel closed-loop controller module specifically for temperature controls Including integrated and easy-to-use online self-optimization Heating and cooling controllers as well as combined controllers with heating and active cooling function feasible Ready-to-use controller structures 2 versions: - FM 355-2 C as a continuous controller; - FM 355-2 S as step or pulse controllers With 4 analog outputs (FM 355-2 C) or 8 digital inputs (FM 355-2 S) to directly control the most common final control elements It is possible to continue closed-loop control operation even if the CPU stops or fails

Technical specifications

Order No. Voltages and currents Load voltage L+ Rated value (DC) permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, max. Power loss, typ. Connection point required front connectors Digital inputs Number of digital inputs Cable length cable length, shielded, max. Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Digital outputs Number of digital outputs cable length, shielded, max. Cable length unshielded, max. Short-circuit protection of the output Limitation of inductive shutdown voltage to

6ES7 3552CH00-0AE0

6ES7 3552SH00-0AE0

Order No. Lamp load, max. Controlling a digital input

6ES7 3552CH00-0AE0

6ES7 3552SH00-0AE0 5W Yes L+ (-2.5 V) 0.1 A 5 mA 150 mA 0.5 mA Yes 100 Hz 0.5 Hz 100 Hz

24 V 28.8 V

24 V 20.4 V 28.8 V

Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 60 C, min. for signal "1" permissible range for 0 to 60 C, max. for signal "0" residual current, max. Parallel switching of 2 outputs for logic links Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. Aggregate current of the outputs (per group) up to 60 C, max. Load impedance range lower limit upper limit 240 4 k 4 200 m; 50 m at 80 mV and thermocouples 4 200 m; 50 m at 80 mV and thermocouples 20 V 40 mA 400 mA

permissible range, lower limit (DC) 20.4 V

310 mA; typ. 260 mA 75 mA; typ. 50 mA 7.8 W 6.5 W 2x 20-pin 8 1,000 m 600 m Yes

270 mA; typ. 220 mA 75 mA; typ. 50 mA 6.9 W 5.5 W 2x 20-pin 8 1,000 m 600 m Yes

24 V -3 to +5 V 13 to 30 V 7 mA

24 V -3 to +5 V 13 to 30 V 7 mA 8 1,000 m 600 m Yes; Electronic L+ (-1.5 V)

Analog inputs Number of analog inputs cable length, shielded, max.

permissible input frequency for volt- 20 V age input (destruction limit), max. permissible input current for current input (destruction limit), max. Input ranges (rated values), voltages 0 to +10 V -1.75 to +11.75 V Yes Yes 40 mA

Yes Yes

5/326

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules

FM 355-2 temperature controller module

Technical specifications (continued)


Order No. Input ranges (rated values), currents 0 to 20 mA 0 to 23.5 mA -3.5 to +23.5 mA 4 to 20 mA Input ranges (rated values), thermoelements Type B Type E Type J Type K Type R Type S Input ranges (rated values), resistance thermometers Pt 100 Characteristic curve linearization programmable for thermoelements for thermoresistor Temperature compensation external temperature compensation with Pt100 internal temperature compensation Analog outputs Number of analg outputs cable length, shielded, max. 4 200 m; 50m at 80 mV and thermocouples Yes 25 mA 18 V Yes Yes Yes Yes Yes Type B, E, J, K, R, S Pt100 (standard) Yes Type B, E, J, K, R, S Pt100 (standard) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6ES7 3552CH00-0AE0 6ES7 3552SH00-0AE0 Order No. Load impedance (in rated range of output) with voltage outputs, min. with voltage outputs, capacitive load, max. with current outputs, max. with current outputs, inductive load, max. Analog value creation Measurement principle Integration and conversion time/ resolution per channel Resolution with overload area (bit including sign), max. Conversion time (per channel) Settling time for resistive load for capacitive load for inductive load Encoder Connection of signal encoders for voltage measurement for current measurement as 4-wire transducer Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Errors/accuracies Linearity error (relative to input area) +/- 0,05 % Temperature error (relative to input areas) Linearity error (relative to output area) Temperature error (relative to output area) Operational limit in overall temperature range Voltage, relative to input area Yes Yes Yes Yes Yes Yes Current, relative to input area +/- 0,6 %; +/-0.6 to +/-0.7% +/- 0,6 %; +/-0.6 to +/-0.7% +/- 0,6 %; +/-0.6 to +/-0.7% +/- 0,5 % +/- 0,6 % +/- 0,06 %; +/-0.06 to +/-0.7% +/- 0,06 %; +/-0.06 to +/-0.7% +/- 0,06 %; +/-0.06 to +/-0.7% +/- 0,005 %/K +/- 0,05 % +/- 0,02 %/K +/- 0,05 % +/- 0,005 %/K Yes 1.5 mA Yes 1.5 mA Yes Yes Yes Yes 0.2 ms 3.3 ms 0.5 ms 0.1 ms 3.3 ms 0.5 ms 14 Bit 100 ms; at 50/60 Hz 14 Bit 100 ms; at 50/60 Hz integrating integrating 1 k 1 F 500 1 milliH 6ES7 3552CH00-0AE0 6ES7 3552SH00-0AE0

Voltage output, Short-circuit protection Voltage output, short-circuit current, max.. Current output, no-load voltage, max. Output ranges, voltage 0 to 10 V -10 to +10 V Output ranges, current 0 to 20 mA 4 to 20 mA Connection of actuators for voltage output 2-conductor connection for current output 2-conductor connection

Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area

Siemens IK PI 2009

5/327

Siemens AG 2008

ET 200M Function modules


Technical specifications (continued)
Order No. Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,04 %; +/-0.04 to +/-0.5% +/- 0,04 %; +/-0.04 to +/-0.5% +/- 0,04 %; +/-0.04 to +/-0.5% +/- 0,4 % +/- 0,5 % 6ES7 3552CH00-0AE0

SIMATIC ET 200 distributed I/Os

FM 355-2 temperature controller module

Ordering data
6ES7 3552SH00-0AE0 FM 355-2 C temperature controller module with 4 analog outputs for 4 continuous-action controllers +/- 0,04 %; +/-0.04 to +/-0.5% +/- 0,04 %; +/-0.04 to +/-0.5% +/- 0,04 %; +/-0.04 to +/-0.5% FM 355-2 S temperature controller module with 8 digital outputs for 4 step or pulse controllers Front connector 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 40 db 20-pin, with FastConnect 1 unit 70 db Bus connectors 1 unit (spare part) Labeling strips

Order No. 6ES7 355-2CH00-0AE0

6ES7 355-2SH00-0AE0

Current, relative to input area

Resistance-type thermometer, relative to input area Voltage, relative to output area Current, relative to output area Interference voltage suppression for f = n x (fl +/- 1 %), fl = interference frequency

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0

Series mode interference 40 db (peak value of interference < rated value of input range), min. common mode voltage (USS < 2.5 V) , min. Control technology Number of closed loop controllers Status information/ alarms/diagnostics Substitute values connectable Isolation Isolation checked with Isolation Isolation, controller between the channels between the channels and the backplane bus Permissible potential difference between inputs and MANA (UCM) 2.5 V DC No Yes; Optocoupler 500 VDC 4 70 db

10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 See Catalog ST 70 6ES7 912-0AA00-0AA0 6ES7 390-5AA00-0AA0 Upgrade single license Labeling sheets for machine inscription

Yes; Parameter- Yes; Parameterizable izable 500 VDC

No Yes; Optocoupler 2.5 V DC 75 V DC / 60 V AC

Slot number label Spare part Shield connection element 80 mm wide, with 2 rows for 4 terminals each Terminal elements 2 units For 2 cables with 2 mm to 6 mm diameter

between M internally and the inputs 75 V DC / 60 V AC Dimensions Dimensions Width Height Depth Weights Weight, approx. 470 g 80 mm 125 mm 120 mm

6ES7 390-5AB00-0AA0 6ES7 390-5BA00-0AA0 6ES7 390-5CA00-0AA0

80 mm 125 mm 120 mm 470 g

For 1 cable with 3 mm to 8 mm diameter For 1 cable with 4 mm to 13 mm diameter

5/328

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Function modules


SM 338 POS input module

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) permissible range, upper limit (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Digital inputs Cable length cable length, shielded, max. Input voltage for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at " to "1", min. Encoder supply 24 V encoder supply 24 V Output current, max. Encoder Number of connectable encoders, max. Connectable encoders Absolute encoder (SSI) 2-wire BEROS Encoder signals, absolute encoder (SSI) cable length, shielded, max. 320 m; 320 m at 125 kHz; 160 m at 250 kHz; 60 m at 500 kHz; 20 m at 1 MHz Yes Yes 3 Yes; L+ (-0.8 V) 900 mA 300 s 2 mA 9 mA -3 to +5 V 11 to 30.2 V 600 m 20-pin 10 mA 160 mA 3W 24 V 28.8 V permissible range, lower limit (DC) 20.4 V 6ES7 338-4BC01-0AB0

Interface between a maximum of 3 absolute position encoders (SSI) and the CPU. To provide the position-encoder values for subsequent processing in the STEP 7 program. Enables the programmable controllers direct response to encoder values in moving systems. Note: SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring systems and preassembled connecting cables for counting and positioning functions. Additional information can be found in the Internet under: http://www.siemens.com/simatic-technology

Status information/ alarms/diagnostics Alarms Diagnostic alarm Isolation Galvanic isolation Dimensions Dimensions Width Height Depth Weights Weight, approx. 235 g 40 mm 125 mm 120 mm no Yes

Siemens IK PI 2009

5/329

Siemens AG 2008

ET 200M Function modules


SM 338 POS input module

SIMATIC ET 200 distributed I/Os

Ordering data
SM 338 POS input module For position sensing with 3 SSI encoders Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Front door, elevated design e.g. for 32-channel modules; for connecting 1.3 mm2/ 16 AWG conductors

Order No. 6ES7 338-4BC01-0AB0 Signal cable Pre-assembled for SSI absolute encoder 6FX2001-5, without Sub-D connector, UL/DESINA 6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0 Length code 0m 100 m 200 m 6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 328-0AA00-7AA0 0m 10 m 20 m 30 m 40 m 50 m 60 m 6ES7 998-8XC01-8YE0 70 m 80 m 90 m 0m 1m 2m 3m 4m 5m 6ES7 998-8XC01-8YE2 6m 7m 8m 9m 0.0 m 0.1 m 0.2 m 6ES7 398-8FA10-8AA0 6ES7 398-8FA10-8BA0 6ES7 398-8FA10-8CA0 6ES7 398-8FA10-8DA0 6ES7 398-8FA10-8EA0 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m

Order No. 6FX5 002-2CC12- 7 7 7 7

1 2 3 A B C D E F G H J K A B C D E F G H J K 0 1 2 3 4 5 6 7 8

SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current "Manual Collection" DVD and the three subsequent updates S7-300 manual Design, CPU data, module data, instruction list German English French Spanish Italian

5/330

Siemens IK PI 2009

Siemens AG 2008

ET 200M IQ Sense Modules and Sensors


IQ-Sense sensor module

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Voltages and currents Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Connection point required front connectors Digital inputs Number of digital inputs Cable length Cable length unshielded, max. Encoder 50 m 8 20-pin 1A 150 mA; typically 24 V 6ES7 338-7XF00-0AB0

Intelligent 8-channel electronics module for S7-300/ET 200M For the connection of up to 8 IQ-Sense sensors: - Optoelectronic sensors - Ultrasound sensors With standard function blocks for the various sensor technologies for simplified handling on a SIMATIC S7 Conventional sensors cannot be operated.

Connectable encoders Description photoelectronic proximity switches and ultrasonic sensors with IQ-Sense, cycle time 2.88 to 6 ms

Status information/ alarms/diagnostics Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 250 g 40 mm 125 mm 120 mm No Yes 500 VDC Yes

Siemens IK PI 2009

5/331

Siemens AG 2008

ET 200M IQ Sense Modules and Sensors


IQ-Sense sensor module

SIMATIC ET 200 distributed I/Os

Ordering data
Sensor module 8x IQ-Sense Sensors for connection to the sensor module Diffuse sensor C40 IQ-Sense design K80 IQ-Sense design with background blanking, K80 IQ-Sense design Retroflective sensor C40 IQ-Sense design K80 IQ-Sense design Ultrasonic sensor M18 IQ-Sense design; range 6 30 cm M18 IQ-Sense design; range 15 100 cm Front connectors 20-pin, with screw contacts 1 unit 100 units 20-pin, with spring-loaded contacts 1 unit 100 units 20-pin, with FastConnect 1 unit Labeling strips 10 units (spare part), for modules with 20-pin front connector Label cover 10 units (spare part), for modules with 20-pin front connector

Order No. 6ES7 338-7XF00-0AB0 S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project 3SF7 240-3JQ00 3SF7 210-3JQ00 3SF7 214-3JQ00 Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige 3SF6 232-3JA00 3SF6 233-3JA00 yellow red SIMATIC Manual Collection Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG, STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors SIMATIC Manual Collection update service for 1 year Current S7 Manual Collection DVD and the three subsequent updates

Order No.

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

3SF7 241-3JQ00 3SF7 211-3JQ00

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 6ES7 998-8XC01-8YE0

6ES7 392-1AJ00-0AA0 6ES7 392-1AJ00-1AB0

6ES7 392-1BJ00-0AA0 6ES7 392-1BJ00-1AB0 6ES7 392-1CJ00-0AA0 6ES7 392-2XX00-0AA0

6ES7 998-8XC01-8YE2

6ES7 392-2XY00-0AA0

5/332

Siemens IK PI 2009

Siemens AG 2008

ET 200M IQ Sense Modules and Sensors


SIMATIC PXO opto proximity switches with IQ-Sense

SIMATIC ET 200 distributed I/Os

Overview

Opto BERO with IQ-Sense, C40 design IQ-Sense

Opto BERO with IQ-Sense, K80 design IQ-Sense

The photoelectric proximity switches react to changes in the received quantity of light. The light beam emitted from the emitter diode is interrupted or reflected by the object to be detected. These sensors detect all objects regardless of their composition, whether metal, wood or plastic.

Depending on the typ of BERO, the interruption or reflection of the light beam is evaluated. The following operating modes are possible with IQ-Sense: 7 Diffuse sensors (energetic) 7 Diffuse sensor (with background suppression) 7 Reflex sensors Features: 7 Designs K80 IQ-Sense and C40 IQ-Sense 7 IntelliTeach functionality 7 Integrated anti-interference function 7 Pre-failure warning (fouling/misalignment)

Technical specifications
Design Diffuse sensor (energetic) Sensing range Standard test object Transmitter (type of light) Supply current Response time LEDs Enclosure material Protection Dimensions Sensing range Standard test object Transmitter (type of light) Supply current Response time LEDs Enclosure material Protection Dimensions mm mm m mm nm mA ms m mm nm mA ms 0.7 200 200 (white) Red LED, 660 50 1 Switching status (yellow), surplus light (green) ABS + PBTP IP67 40 40 53 83 65 25 0.2 ... 1 200 200 (white) IR-LED, 880 50 2 Switching status (yellow), surplus light (green) PBTP IP67 83 65 25 PBTP IR LED, 880 2 C40 design IQ-Sense K80 design IQ-Sense

Diffuse sensor with background suppression

Siemens IK PI 2009

5/333

Siemens AG 2008

ET 200M IQ Sense Modules and Sensors


SIMATIC PXO opto proximity switches with IQ-Sense

SIMATIC ET 200 distributed I/Os

Technical specifications (continued)


Design Reflex sensor Sensing range Standard test object Transmitter (type of light) Supply current Response time LEDs Enclosure material Protection Dimensions mm nm mA ms m 6 Reflector D84, 3RX7916 Red LED 660 nm, polarized 50 1 Switching status (yellow), surplus light (green) ABS + PBTP IP67 40 40 53 83 65 25 PBTP 8 C40 IQ-Sense K80 IQ-Sense

Selection and Ordering Data


Version Photoelectric sensors for connection to the 4 IQ-Sense sensor module Design C40 IQ-Sense K80 IQ-Sense Type Diffuse sensor Reflex sensor Diffuse sensor Diffuse sensor (with background suppression) Reflex sensor Order No. 3SF7 240-3JQ00 3SF7 241-3JQ00 3SF7 210-3JQ00 3SF7 214-3JQ00 3SF7 211-3JQ00

5
Dimensions
65

25

L E D
N S D 0 _ 0 1 1 8 4 a

max.90

62

83

73

5 5

4 6

4 0

NSA0_00330

8,2

5,5

10 20 30 36 M12x1
50

5 ,3 x 7 ,3 3 0 4 0 M 1 2 x 1 4 0

8,1

Opto BERO with IQ-Sense, K80 IQ-Sense design

Opto BERO with IQ-Sense, C40 IQ-Sense design

5/334

Siemens IK PI 2009

6 9

Siemens AG 2008

ET 200M IQ Sense Modules and Sensors


SIMATIC PXS sonar proximity switches with IQ-Sense

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Sensing range Rated value Maximum value Standard test object Differential travel H (adjustable) Repeat accuracy R Operating voltage (DC) Rated operational current Ie No-load current I0 Adjustment / configuration cm cm mm mm mm 5 ... 30 5 ... 50 10 10 3 ... 30 1 of IQ-Sense of IQ-Sense of IQ-Sense Beginning and end of switching range via IQ-Sense (IntelliTeach) or local teach-in via potentiometer kHz Hz ms ms 400 8 54 13.44 yellow LED nickel-plated brass, Transformer cover CRASTIN, Transformer surface epoxy resin IP67 C C 25 ... +70 40 ... +85 200 4 110 26.88 15 ... 100 15 ... 150 20 20 10 ... 100 2 3SF62 323JA00 3SF62 333JA00

The sonar BEROs of the M18 IQ compact series are ready-touse complete units with a cylindrical M18 housing for connection to the S7-300/ET 200M IQ-Sense module SM338, 8IQ-Sense. 7 Five operating modes: Operation as measuring sensor (analog signal) Diffuse sensor with background blanking Diffuse sensor with differential travel Diffuse sensor with foreground and background blanking Retroreflective sensor. 7 Statically configurable using STEP 7, 7 Dynamically configurable using an S7 function block 7 Measured distance to object is always transmitted 7 Synchronizable, multiplex operation 7 Temperature compensation, 7 Connection with M12 connector 7 Non-polarized 2-conductor connection (protected against polarity reversal), 7 Channel-specific system diagnosis (e.g. wire-break, short-circuit, parameterization error).

Ultra-sound frequency Switching frequency f Response time Measuring rate Status display Casing material

Degree of protection Ambient temperature Operation Storage

Selection and Ordering Data


Version Ultrasonic sensors For connection to IQ-Sense Type M18 IQ-Sense Sensing range (cm) 5 ... 30 15 ... 100 Order No. 3SF62 323JA00 3SF62 333JA00

Siemens IK PI 2009

5/335

Siemens AG 2008

ET 200M Special modules


SM 374 simulator

SIMATIC ET 200 distributed I/Os

Overview

Technical specifications
Order No. Current consumption from backplane bus DC 5 V, max. Power loss, typ. Digital inputs Number of digital inputs Digital outputs Number of digital outputs Isolation Galvanic isolation, digital inputs between the channels and the backplane bus Isolation, digital outputs between the channels and the backplane bus No No 16; LEDs 16; Switch 80 mA 0.35 W 6ES7 374-2XH01-0AA0

Simulator module for program testing during commissioning and ongoing operation For the simulation of sensor signals using switches For display of signal conditions on the outputs using LED Simulation of - 16 inputs or - 16 outputs or - 8 inputs and 8 outputs Function can be directly adjusted on the module using a screwdriver

Dimensions Dimensions Width Height Depth Weights Weight, approx. 190 g Order No. 6ES7 374-2XH01-0AA0 40 mm 125 mm 120 mm

Ordering data
SM 374 simulator module incl. bus connectors, labeling strips Bus connectors 1 unit, spare part Labeling strips 10 units (spare part) Label cover 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red

6ES7 390-0AA00-0AA0 6ES7 392-2XX00-0AA0 6ES7 392-2XY00-0AA0

2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4

6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0

5/336

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Special modules


DM 370 dummy module

Overview

Technical specifications
Order No. Current consumption from backplane bus DC 5 V, max. Power loss, max. Dimensions Dimensions Width Height Depth Weights Weight, approx. 180 g Order No. 6ES7 370-0AA01-0AA0 40 mm 125 mm 120 mm 5 mA 0.03 W 6ES7 370-0AA01-0AA0

Ordering data
DM 370 dummy module

Dummy module for reserving slots for non-parameterized signal modules Structure and address allocation is retained when replaced with a signal module

incl. bus connectors, labeling strips Bus connectors 1 unit, spare part Labeling strips 10 units (spare part) Label cover 10 units (spare part) S7 SmartLabel V3.0 Software for automatic labeling of modules based on data of the STEP 7 project Single license Upgrade single license Labeling sheets for machine inscription For 16-channel signal modules, DIN A4, for printing with laser printer; 10 units petrol light-beige yellow red 6ES7 392-2AX00-0AA0 6ES7 392-2BX00-0AA0 6ES7 392-2CX00-0AA0 6ES7 392-2DX00-0AA0 2XV9 450-1SL03-0YX0 2XV9 450-1SL03-0YX4 6ES7 392-2XY00-0AA0 6ES7 392-2XX00-0AA0 6ES7 390-0AA00-0AA0

Siemens IK PI 2009

5/337

Siemens AG 2008

ET 200M Communication
CP 340

SIMATIC ET 200 distributed I/Os

Overview
The economical complete solution for serial communication via point-to-point links. 3 versions with different transmission interfaces: - RS 232C (V.24) - 20 mA (TTY) - RS 422/RS 485 (X.27) Implemented protocols: - ASCII - 3964 (R) (not for RS 485) - Printer driver Simple parameterization via a parameterization tool integrated into STEP 7

Technical specifications

Order No. Supply voltages Rated value DC 24 V Current consumption from backplane bus DC 5 V, max. Power loss, max. Power loss, typ. interfaces Number of interfaces Physical interface, 20mA (TTY) interface physics, RS 232C (V.24) interface physics, RS 422/RS 485 (X.27) Transmission speed, max. Transmission speed, min. Connection point PtP Voltage supply Point-to-point Cable length, max. supported printers Integrated protocol driver 3964 (R) ASCII customer-specific drivers reloadable RK512 Telegram length, max. 3964 (R) ASCII

6ES7 340-1AH02-0AE0

6ES7 340-1BH02-0AE0

6ES7 340-1CH02-0AE0

No; Power supply via backplane bus 5V 165 mA 0.85 W 0.6 W 1; isolated Yes

No; Power supply via backplane bus 5V 190 mA 0.95 W 0.85 W 1; isolated Yes

No; Power supply via backplane bus 5V 165 mA 0.85 W 0.6 W 1; isolated

Yes 19.2 kBit/s 2.4 kBit/s 9-pin Sub-D connector over backplane bus 15 m HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined Yes Yes No No 1,024 Byte 1,024 Byte 19.2 kBit/s 2.4 kBit/s 9-pin Sub-D socket over backplane bus 1,000 m; (100 m active, 1000 m passive) HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined Yes Yes No No 1,024 Byte 1,024 Byte 19.2 kBit/s 2.4 kBit/s 15-pin Sub-D socket over backplane bus 1,200 m HP-Deskjet, HP-Laserjet, IBM-Proprinter, user-defined Yes Yes No No 1,024 Byte 1,024 Byte

5/338

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Communication
CP 340

Technical specifications (continued)


Order No. Transmission speed, 20 mA (TTY) with 3964 (R) protocol, max. with ASCII protocol, max. with printer driver, max., Transmission speed, RS 422/485 with 3964 (R) protocol, max. with ASCII protocol, max. with printer driver, max. Transmission speed, RS232 with 3964 (R) protocol, max. with ASCII protocol, max. with printer driver, max., Software Block FB length in RAM, max. Dimensions Dimensions Width Height Depth Weights Weight, approx. 300 g Order No. 6ES7 340-1AH02-0AE0 20 mA (TTY) connecting cable For linking to SIMATIC S7 5m 10 m 50 m 6ES7 902-1AB00-0AA0 6ES7 902-1AC00-0AA0 6ES7 902-1AD00-0AA0 6ES7 340-1BH02-0AE0 CP 340 communications processor With one RS 422/485 (X.27) interface RS 422/485 connecting cable For linking to SIMATIC S7 5m 10 m 50 m 6ES7 902-3AB00-0AA0 6ES7 902-3AC00-0AA0 6ES7 902-3AG00-0AA0 6ES7 902-2AB00-0AA0 6ES7 902-2AC00-0AA0 6ES7 902-2AG00-0AA0 6ES7 340-1CH02-0AE0 300 g 300 g Order No. 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 40 mm 125 mm 120 mm 2,700 Byte; Data communication, sending and receiving 2,700 Byte; Data communication, sending and receiving 2,700 Byte; Data communication, sending and receiving 19.2 kBit/s 9.6 kBit/s 9.6 kBit/s 19.2 kBit/s 9.6 kBit/s 9.6 kBit/s 19.2 kBit/s 9.6 kBit/s 9.6 kBit/s 6ES7 340-1AH02-0AE0 6ES7 340-1BH02-0AE0 6ES7 340-1CH02-0AE0

Ordering data
CP 340 communications processor With one RS 232 C (V.24) interface RS 232 connecting cable For linking to SIMATIC S7 5m 10 m 15 m CP 340 communications processor With one 20 mA (TTY) interface

Siemens IK PI 2009

5/339

Siemens AG 2008

ET 200M Communication
CP 341

SIMATIC ET 200 distributed I/Os

Overview
For powerful, high-speed serial communication via point-to-point links 3 versions with different physical properties: - RS 232C (V.24) - 20 mA (TTY), - RS 422/RS 485 (X.27) Implemented protocols: ASCII, 3964 (R), RK 512, customer-specific protocols (reloadable) Simple parameterization via a parameterization tool integrated into STEP 7

Technical specifications

Order No. Supply voltages Rated value DC 24 V Current consumption from backplane bus DC 5 V, max. from supply voltage L+, max. Power loss, max. interfaces Number of interfaces Physical interface, 20mA (TTY) interface physics, RS 232C (V.24) interface physics, RS 422/RS 485 (X.27) Transmission speed, max. Transmission speed, min. Connection point PtP Voltage supply Point-to-point Cable length, max. Integrated protocol driver 3964 (R) ASCII customer-specific drivers reloadable RK512 Telegram length, max. 3964 (R) ASCII RK 512

6ES7 341-1AH01-0AE0

6ES7 341-1BH01-0AE0

6ES7 341-1CH01-0AE0

Yes 70 mA 200 mA 4.8 W 1; isolated Yes

Yes 70 mA 200 mA 4.8 W 1; isolated Yes

Yes 70 mA 240 mA 5.8 W 1; isolated

Yes 76.8 kBit/s 0.3 kBit/s 9-pin Sub-D connector 3 screw terminals: L+, M, GND 15 m Yes Yes Yes Yes 1,024 Byte 1,024 Byte 1,024 Byte 19.2 kBit/s 0.3 kBit/s 9-pin Sub-D connector 3 screw terminals: L+, M, GND 1,000 m Yes Yes Yes Yes 1,024 Byte 1,024 Byte 1,024 Byte 76.8 kBit/s 0.3 kBit/s 15-pin Sub-D connector 3 screw terminals: L+, M, GND 1,200 m Yes; not with RS 485 Yes Yes Yes; not with RS 485 1,024 Byte 1,024 Byte 1,024 Byte

5/340

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Communication
CP 341

Technical specifications (continued)


Order No. Transmission speed, 20 mA (TTY) with 3964 (R) protocol, max. with ASCII protocol, max. 76.8 kBit/s 76.8 kBit/s; 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6 and 76.8 kbps (76.8 kbps only achievable with half duplex) 76.8 kBit/s 76.8 kBit/s 76.8 kBit/s; 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6 and 76.8 kbps (76.8 kbps only achievable with half duplex) 76.8 kBit/s 76.8 kBit/s 76.8 kBit/s; 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6 and 76.8 kbps (76.8 kbps only achievable with half duplex) 76.8 kBit/s 6ES7 341-1AH01-0AE0 6ES7 341-1BH01-0AE0 6ES7 341-1CH01-0AE0

with RK 512 protocol, max. Transmission speed, RS 422/485 with 3964 (R) protocol, max. with ASCII protocol, max.

with RK 512 protocol, max. Transmission speed, RS232 with 3964 (R) protocol, max. with ASCII protocol, max.

with RK 512 protocol, max. Software Block FB length in RAM, max. Dimensions Dimensions Width Height Depth Weights Weight, approx.

5
5,500 Byte; Data communication, sending and receiving 5,500 Byte; Data communication, sending and receiving

5,500 Byte; Data communication, sending and receiving

40 mm 125 mm 120 mm 300 g Order No. 6ES7 341-1AH01-0AE0

40 mm 125 mm 120 mm 300 g

40 mm 125 mm 120 mm 300 g Order No.

Ordering data
CP 341 communications processor With one RS 232 C (V.24) interface RS 232 connecting cable For linking to SIMATIC S7 5m 10 m 15 m CP 341 communications processor With one 20 mA (TTY) interface 20 mA (TTY) connecting cable For linking to SIMATIC S7 5m 10 m 50 m CP 341 communications processor With one RS 422/485 (X.27) interface

RS 422/485 connecting cable For linking to SIMATIC S7 5m 10 m 50 m Loadable drivers for CP 341 MODBUS master (RTU format) Single license Single license, without software or documentation MODBUS slave (RTU format) Single license Single license, without software or documentation 6ES7 870-1AB01-0YA0 6ES7 870-1AB01-0YA1 6ES7 870-1AA01-0YA0 6ES7 870-1AA01-0YA1 6ES7 902-3AB00-0AA0 6ES7 902-3AC00-0AA0 6ES7 902-3AG00-0AA0

6ES7 902-1AB00-0AA0 6ES7 902-1AC00-0AA0 6ES7 902-1AD00-0AA0 6ES7 341-1BH01-0AE0

6ES7 902-2AB00-0AA0 6ES7 902-2AC00-0AA0 6ES7 902-2AG00-0AA0 6ES7 341-1CH01-0AE0

Data highway (DF1 protocol) Single license Single license, without software or documentation 6ES7 870-1AE00-0YA0 6ES7 870-1AE00-0YA1

Siemens IK PI 2009

5/341

Siemens AG 2008

ET 200M Power Supplies


Overview

SIMATIC ET 200 distributed I/Os

2 A, 5 A, 10 A load power supplies

Load current supplies for S7-300/ET 200M To convert the line voltage to the required operating voltage (24V DC) Output current 2 A, 5 A or 10 A

Technical specifications

Power supply, type Order No. Order No. SIPLUS Input Rated voltage Vin rated

2A 6ES7 307-1BA000AA0

2A 6ES7 305-1BA800AA0 6AG1 305-1BA802AA0 1)

5A 6ES7 307-1EA000AA0

5A 6ES7 307-1EA800AA0 6AG1 307-1EA802AA0 1)

10 A 6ES7 307-1KA010AA0 2) 6AG1 307-1KA014AA0 Single-phase AC 120/230 V AC Settable via selector switch on device 85 ... 132/ 170 ... 264 V AC 2.3 x -pole, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 ... 63 Hz 4.1/1.8 A < 55 A, < 3 ms < 3.3 A2s T 6.3 A/250 V (not accessible) From 10 A, Characteristic C

Single-phase AC 120/230 V AC Settable via selector switch on device 85 ... 132 V/ 170 ... 264 V AC 2.3 x -pole, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 ... 63 Hz 0.9/0.6 A < 20 A, < 3 ms < 1.0 A s T 1.6 A/250 V (not accessible) 3 A, Characteristic C
2

DC voltage 24 V ... 110 V DC Wide-range input 16.8 ... 138 V DC 154 V; 0.1 s > 10 ms at Vin rated 2.7-0.6 A (4-0.9 A) < 20 A, < 10 ms <5A s T 6.3 A/250 V (inaccessible) At and above 10 A, C characteristic, suitable for DC
2

Single-phase AC 120/230 V AC Settable via selector switch on device 85 ... 132 V/ 170 ... 264 V AC 2.3 x -pole, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz; 47 ... 63 Hz 2.1/1.3 A < 45 A, < 3 ms < 1.2 A s F 4 A/250 V (not accessible) From 6 A, Characteristic C
2

Single-phase AC 120/230 V AC Set via switch on device 93 ... 132 V AC/ 187 ... 264 V AC 2.3 x Vin rated, 1.3 ms > 20 ms at Vin = 93/187 V 50/60 Hz, 47 ... 63 Hz 2.1/1.2 A < 45 A, < 3 ms < 1.8 A s (typ. 1.2 A2s) T 3.15 A/250 V (not accessible) At and above 10 A, Characteristic C or at and above 6 A, Characteristic D
2

Voltage range Overvoltage strength Mains buffering Iout rated Rated line frequency; range Rated current Iin rated Inrush current limitation (+25C) I t Integrated line-side fuse Recommended circuit-breaker (IEC 898) in mains supply line
2

1)

2)

SIPLUS module for temperature range -25 ... +60C and use under medial load (e.g. sulphur chloride atmosphere). This SIPLUS power supply conforms with standards for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). SIPLUS module for use under medial load (e.g. sulphur-chloride atmosphere)

5/342

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Power Supplies

2 A, 5 A, 10 A load power supplies

Technical specifications (continued)


Power supply, type Order No. Order No. SIPLUS Output Rated voltage Vout rated Total tolerance Stat. mains compensation Stat. load compensation Residual ripple (clock frequency: approx. 50 kHz) Spikes (bandwidth: 20 MHz) Setting range Status display Power ON/OFF behavior Starting delay/voltage rise Rated current Iout rated Current range Up to +45 C Up to +60 C Dyn. V/I with Starting on short circuit Short-circuit in operation Parallel connection for increased output Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Control Dyn. mains compensation (Vin rated 15 %) Dyn. load compensation (Iout: 50/100/50 %) Settling time Load step from 50 to 100 % Load step from 100 to 50 % Protection and monitoring Output overvoltage protection Additional control loop, shutdown at approx. 30 V, automatic restart 2.2 ... 2.6 A Electronic shutdown, automatic restart <4A Additional control loop, shutdown at approx. 30 V, automatic restart 3.3 ... 3.9 A Electronic shutdown, automatic restart <2A Additional control loop, shutdown at approx. 30 V, automatic restart 5.5 ... 6.5 A Electronic shutdown, automatic restart <9A Additional control loop, shutdown at approx. 30 V, automatic restart 5.5 ... 6.5 A Electronic shutdown, automatic restart <5A Additional control loop, shutdown at approx. 30 V, automatic restart 11 ... 12 A Electronic shutdown, automatic restart < 10 A < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) typ. 0.1 ms typ. 0.1 ms < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.2 ms) < 5 ms < 5 ms 0.3 % Vout 0.8 % Vout 0.3 % Vout 2.5 % Vout 0.3 % Vout 2.5 % Vout 0.3 % Vout 3 % Vout 0.3 % Vout 2.5 % Vout Approx. 83 % Approx. 10 W Approx. 75% Approx. 87 % Approx. 84 % Approx. 23 W Approx. 87 % Approx. 34 W Approx. 16 W (24 W) Approx. 18 W typ. 10 A for 90 ms typ. 10 A for 90 ms Not permissible typ. 9 A for 270 ms typ. 9 A for 270 ms Yes, 2 units typ. 20 A for 75 ms typ. 20 A for 75 ms Not permissible typ. 20 A for 180 ms typ. 20 A for 80 ms Not permissible typ. 35 A for 80 ms typ. 35 A for 150 ms Not permissible 0 ... 2 A 0 ... 2 A 0 ... 2 A (3 A) 0 ... 3 A (3 A) 0 ... 5 A 0 ... 5 A 0 ... 5 A 0 ... 5 A 0 ... 10 A 0 ... 10 A Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % < 150 mVpp (typ. < 20 mVpp) < 240 mVpp (typ. < 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 3 s/typ. 60 ms 2A 2A 6ES7 307-1BA000AA0 2A 6ES7 305-1BA800AA0 6AG1 305-1BA802AA0 1) Controlled, isolated DC voltage 24 V DC 3% Approx. 0.2 % Approx. 0.4 % < 150 mVpp (typ. < 30 mVpp) < 240 mVpp (typ. < 150 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 3 s (typ.7 ms)/ typ. 5 ms 2A (3 A with Vin > 24 V) Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.2 % < 150 mVpp (typ. 40 mVpp) < 240 mVpp (typ. 90 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 2 s/typ. 60 ms 5A 5A 6ES7 307-1EA000AA0 5A 6ES7 307-1EA800AA0 6AG1 307-1EA802AA0 1) Controlled, isolated DC voltage 24 V DC 3% Approx. 0.2 % Approx. 0.4 % < 150 mVpp (typ. 40 mVpp) < 240 mVpp (typ. 90 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 3 s/typ.100 ms 5A Stabilized, floating direct voltage 24 V DC 3% Approx. 0.1 % Approx. 0.5 % < 150 mVpp (typ. 40 mVpp) < 240 mVpp (typ. 100 mVpp) Green LED for 24 V O.K. No overshoot of Vout (soft start) < 1.5 s/typ. 80 ms 10 A 10 A 6ES7 307-1KA010AA0

Current limitation Short-circuit protection

RMS sustained short-circuit current Overload/short-circuit indicator

Siemens IK PI 2009

5/343

Siemens AG 2008

ET 200M Power Supplies


Technical specifications (continued)
Power supply, type Order No. Order No. SIPLUS Safety Electrical isolation primary/secondary 2A

SIMATIC ET 200 distributed I/Os

2 A, 5 A, 10 A load power supplies

2A 6ES7 305-1BA800AA0 6AG1 305-1BA802AA0 1)

5A 6ES7 307-1EA000AA0

5A 6ES7 307-1EA800AA0 6AG1 307-1EA802AA0 1)

10 A 6ES7 307-1KA010AA0

6ES7 307-1BA000AA0

Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178

Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178, creepages and clearances > 5 mm Class I < 3.5 mA (typ. 0.7 mA) Yes Yes Yes, UL-listed (UL 508), file E143289, CSA (CSA22.2 no. 14-95) -

Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178

Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178, creepages and clearances > 8 mm Class I < 3.5 mA (typ. 0.3 mA) Yes Yes Yes, UL-listed (UL 508), file E143289, CSA (CSA22.2 no. 14-95) -

Yes, SELV output voltage Vout acc. to EN 60950 and EN 50178

Protective class Discharge current TV test CE marking UL/cUL (CSA) approval

Class I < 3.5 mA (typ. 0.7 mA) Yes Yes Yes, UL listed (UL 508), File E143289, CSA (CSA 22.2 No. 14-95) Yes, Class I Div. 2 Group A, B, C, D, T4 in the S7-300 system IP20

Class I < 3.5 mA (typ. 0.3 mA) Yes Yes Yes, UL listed (UL 508), File E143289, CSA (CSA 22.2 No. 14-95) Yes, Class I Div. 2 Group A, B, C, D, T 4 in the S7-300 system IP20

Class I < 3.5 mA (typ. 0.5 mA) Yes Yes Yes, UL listed (UL 508) File E143289, CSA (CSA 22.2 No. 14-95) Yes, Class I Div. 2, A, B, C, D, T4 in the S7-300 system IP20

FM approval

Appr. for use in marine vessels Degree of protection (EN 60529) EMC Interference emission Line harmonics limitation Interference immunity Operating specifications Ambient temperature range Transportation and storage temperature range Humidity rating

Yes, GL, LRS IP20

Yes, GL, LRS IP20

EN 55022 Class B Not applicable EN 61000-6-2 0 ... +60 C with natural convection -40 ... +85 C Climatic class 3K3 acc. to EN 60721, no condensation

EN 55011 Class A Not applicable EN 61000-6-2 -25C ... +70C with natural convection - 40 ... + 85 C Climate class 3K5 to EN 60721, transient condensation permitted

EN 55022 Class B EN 61000-3-2 EN 61000-6-2

EN 55011 Class A EN 61000-6-2

EN 55022 Class B EN 61000-3-2 EN 61000-6-2 0 ... +60C with natural convection -40 ... +85 C Climatic class 3K3 acc. to EN 60721, no condensation

0 ... +60 C with natu- -25C ... +70C with ral convection natural convection -40 ... +85 C Climatic class 3K3 acc. to EN 60721, no condensation - 40 ... + 85 C Climate class 3K5 to EN 60721, transient condensation permitted

Mechanical specifications Connections Mains input L, N, PE (DC input: L+1, M1, PE) One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 2 screw-type terminals for 0.5 to 2.5 mm2 2 screw-type terminals for 0.5 to 2.5 mm2 50 x 125 x 120 0.42 kg Snap-mounting on S7 rail Mounting adapter for DIN rail and PS-CPU power connector Solid/finely-stranded per screw-type terminal for 0.5 mm to 2.5 mm2 3 screw-type terminals for 0.5 mm to 2.5 mm2 3 screw-typeterminals for 0.5 mm to 5 mm2 80 x 125 x 120 0.75 kg Snaps onto S7 busbar Mounting adapter for DIN rail and PS-CPU power connector One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 3 screw-type terminals for 0.5 to 2.5 mm2 3 screw-type terminals for 0.5 to 2.5 mm2 80 x 125 x 120 0.74 kg Snap-mounting on S7 rail Mounting adapter for DIN rail and power connector Solid/finely-stranded per screw-type terminal for 0.5 mm to 2.5 mm2 3 screw-type terminals for 0.5 mm to 2.5 mm2 3 screw-type terminals for 0.5 mm to 2.5 mm2 80 x 125 x 120 0.57 kg Snaps onto S7 busbar Mounting adapter for DIN rail and PS-CPU power connector One screw-type terminal each for 0.5 to 2.5 mm2 singlecore/finely stranded 4 screw-type terminals for 0.5 to 2.5 mm2 4 screw-type terminals for 0 .5 to 2.5 mm2 120 x 125 x 120 1) 1.1 kg Snap-mounting on S7 rail 1) Mounting adapter for DIN rail and PS-CPU power connector

Output L+ Output M

Dimensions (W x H x D) in mm Weight approx. Mounting Accessories

1)

SIPLUS module for temperature range -25 ... +60C and use under medial load (e.g. sulphur chloride atmosphere). This SIPLUS power supply conforms with standards for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1).

5/344

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os

ET 200M Power Supplies

2 A, 5 A, 10 A load power supplies

Ordering data
PS 305/307 load power supply incl. power connector 120/230 V AC / 24 V DC; 2 A 24 110 V DC / 24 V DC; 2 A, for extended temperature range 120/230 V AC / 24 V DC; 5 A 120/230 V AC / 24 V DC; 5 A, for extended temperature range 120/230 V AC / 24 V DC; 10 A

Order No. SIPLUS load power supply PS 305/307 6ES7 307-1BA00-0AA0 6ES7 305-1BA80-0AA0 6ES7 307-1EA00-0AA0 6ES7 307-1EA80-0AA0 6ES7 307-1KA01-0AA0 for temperature range -25 +60 C and use under medial load (e.g. sulphur chloride atmosphere). Conforms with standard for electronic equipment used on rolling stock (EN 50155, temperature T1, category 1). 24 110 V DC / 24 V DC; 2 A 120/230 V AC / 24 V DC; 5 A Installation adapter For snapping the PS 307 onto a 35 mm DIN rail (EN 50022) PS-CPU power connector Spare part

Order No.

6AG1 305-1BA80-2AA0 6AG1 307-1EA80-2AA0 6ES7 390-6BA00-0AA0

6ES7 390-7BA00-0AA0

Siemens IK PI 2009

5/345

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Overview
Compact, cost-effective I/O devices for processing digital signals Design without control cabinet with degree of protection IP65/67 with flexible and fast connections Comprises a basic module and various connection blocks for application-specific implementation options: - ECOFAST: 2 x RS 485 hybrid fieldbus connection with identification plug for setting the PROFIBUS address - M12: 2 x M12 and 2 x 7/8" with 2 rotary coding switches for assigning the PROFIBUS address Connection block contains T-functionality for bus and power supply so that during commissioning and service, the modules can be disconnected from and reconnected to the PROFIBUS without interruption Module variance: 8DI, 16DI, 8DI/8DO (1.3 A), 8DI/8DO (2.0 A), 8DO (2.0 A), 16DO (0.5 A) Transmission rates up to 12 Mbit/s Failsafe DI modules 4/8 F-DI with safety-related signal processing according to PROFIsafe

Technical specifications
Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Current consumption from supply voltage 1L+, max. Power loss, typ. FH technology Module for failsafe applications Protocols PROFIBUS DP protocol PROFIBUS DP Transmission speed, max. 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 8 8; All mounting positions up to 55 C 30 m Yes 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 16 16; All mounting positions up to 55 C 30 m Yes 12 MBit/s Yes Yes Yes Yes 70 mA; typically 2.4 W 70 mA; typically 3.6 W 100 mA 3W 24 V Yes 24 V Yes 24 V No 6ES7 141-3BF00-0XA0 6ES7 141-3BH00-0XA0 6ES7 148-3FA00-0XB0

Digital inputs Number of digital inputs Number of simultanneously controllable inputs Cable length Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. - at "1" to "0", max. 3 ms; Typ. 3 ms; typically 3 ms; Typ. 3 ms; typically 7 mA 7 mA 3.7 mA 24 V -3 to +5 V 13 to 30 V 24 V -3 to +5 V 13 to 30 V 24 V -30 to +5 V 15 to 30 V 30 m Yes 8; 8 single-channel, 4 two-channel 8; 8 single channel, 4 two-channel

5/346

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Technical specifications (continued)


Order No. Encoder supply Number of outputs Output voltage Output current, rated value Short-circuit protection Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Status indicator Alarms Alarms Diagnoses Diagnostics Diagnostics indication LED Collective error SF (red) Status indicator digital input (green) Channel error indicator F (red) Isolation Isolation checked with Isolation between PROFIBUS DP all all other circuits Galvanic isolation, digital inputs between the channels Permissible potential difference between different circuits Standards, approvals, certificates Highest safety class achievable in safety mode to EN 954 to IEC 61508 General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx. 210 g 210 g 220 g 60 mm 210 mm 28 mm 60 mm 210 mm 28 mm 60 mm 210 mm 28 mm 80DBh 80DAh Cat. 3 (single-channel), Cat. 4 (two-channel) SIL 2 (single-channel), SIL 3 (two-channel) 75 VDC / 60 VAC 75 VDC / 60 VAC 75 VDC / 60 VAC No No No Yes Yes Yes 500 VDC 500 VDC 500 V AC for 1 min. Yes Yes No Yes Yes No Yes Yes No Yes; Diagnostic information readable Yes; Diagnostic information readable No No Yes Yes Yes 1.5 mA Yes 1.5 mA No 8 24 V DC 1 A; Aggregate current up to 55 C Yes; electronic 8 24 V DC 1 A; Aggregate current up to 55 C Yes; electronic 2 min. L+ (-1.5 V) 300 mA Yes 6ES7 141-3BF00-0XA0 6ES7 141-3BH00-0XA0 6ES7 148-3FA00-0XB0

Siemens IK PI 2009

5/347

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Technical specifications (continued)


Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Voltages and currents Load voltage 2L+ Rated value (DC) Reverse polarity protection Current consumption from load voltage 2L+ (without load), max. from supply voltage 1L+, max. Power loss, typ. Protocols PROFIBUS DP protocol Yes 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 8 30 m Yes 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 16 30 m Yes; Electronic 60 mA; typically 80 mA; typically 70 mA; typically 70 mA; typically 4W 4W Load impedance range lower limit upper limit Status information/ alarms/diagnostics Status indicator Alarms Alarms Diagnoses Diagnostics Yes; Diagnostic information readable Yes Yes No 500 VDC Yes Yes; Diagnostic information readable Yes Yes No 500 VDC Yes No No Yes Yes 12 4 k 12 4 k 24 V Yes 24 V Yes 24 V Yes 24 V Yes 6ES7 1423BF00-0XA0 6ES7 1423BH00-0XA0 Order No. Aggregate current of the outputs (per group) up to 55 C, max. 4 A; 4 A each for sockets X1, X3, X5, X7 and 4 A each for sockets X2, X4, X6, X8; note the current carrying capacity of the cable 4 A; Please note the current carrying capacity of the cable! 6ES7 1423BF00-0XA0 6ES7 1423BH00-0XA0

PROFIBUS DP Transmission speed, max.

Digital outputs Number of digital outputs Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage for signal "1", min. Output current for signal "1" rated value for signal "1" permissible range for 0 to 55 C, min. for signal "1" permissible range for 0 to 55 C, max. Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. 100 Hz 0.5 Hz; to IEC 947-5-1, DC13 1 Hz 100 Hz 0.5 Hz; to IEC 947-5-1, DC13 1 Hz No Yes No Yes 2A 5 mA 2.4 A 0.5 A 5 mA 1A 0.1 mA 2L+ (-0.8 V) 2L+ (-0.8 V) Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Channel error indicator F (red) Isolation Isolation checked with Isolation between PROFIBUS DP all all other circuits Isolation, digital outputs between the channels Permissible potential difference between different circuits General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx.

Short-circuit protection of the output Yes; Electronic

4 A per channel 1.4 A (per channel) 2L+ (-44 V) 10 W Yes 2L+ (-47 V) 5W Yes

No 75 VDC / 60 VAC 80DDh

No 75 VDC / 60 VAC 80FBh

for signal "0" residual current, max. 0.5 mA

60 mm 210 mm 28 mm 210 g

60 mm 210 mm 28 mm 210 g

on lamp load, max.

5/348

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Technical specifications (continued)


Order No. Supply voltages Supply voltage of electronics 1L+ Rated value (DC) reverse polarity protection Voltages and currents Load voltage 2L+ Rated value (DC) Reverse polarity protection Current consumption from load voltage 2L+ (without load), max. from supply voltage 1L+, max. Power loss, typ. Protocols PROFIBUS DP protocol PROFIBUS DP Transmission speed, max. 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 8 8; All mounting positions up to 55 C Yes 12 MBit/s; 9.6 / 19.2 / 45.45 / 93.75 / 187.5 / 500 Kbit/s; 1.5 / 3 / 6 / 12 Mbit/s 8 8; All mounting positions up to 55 C Yes Load impedance range lower limit upper limit 24 V -3 to +5 V 13 to 30 V 7 mA 24 V -3 to +5 V 13 to 30 V 7 mA Encoder supply Number of outputs Output voltage Output current, rated value 8 24 V DC 0.75 A; up to 55C max. 0.75 A (summation current) Yes; electronic 1 A; Up to 55C max. 1 A (summation current) Yes; electronic 8 12 4 k 12 4 k Yes Yes on lamp load, max. Aggregate current of the outputs (per group) up to 55 C, max. 4 A; 4 A each for sockets X1, X3, X5, X7 and 4 A each for sockets X2, X4, X6, X8; note the current carrying capacity of the cable 5.2 A; Please note the current carrying capacity of the cable! 60 mA; typically 60 mA; typically 70 mA; typically 70 mA; typically 5W 5W 24 V No 24 V Yes 24 V No 24 V Yes 6ES7 1433BH00-0XA0 6ES7 1433BH10-0XA0 Order No. Output current for signal "1" rated value for signal "1" permissible range for 0 to 55 C, min. for signal "1" permissible range for 0 to 55 C, max. Parallel switching of 2 outputs for increased power for redundant control of a load Switching frequency with resistive load, max. with inductive load, max. 100 Hz 0.5 Hz; to IEC 947-5-1, DC13 1 Hz 100 Hz 0.5 Hz; to IEC 947-5-1, DC13 1 Hz No Yes No Yes 2A 5 mA 2.4 A 1.3 A 5 mA 1.8 A 0.5 mA 6ES7 1433BH00-0XA0 6ES7 1433BH10-0XA0

for signal "0" residual current, max. 0.5 mA

Digital inputs Number of digital inputs Number of simultanneously controllable inputs Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. - at "1" to "0", max. Digital outputs Number of digital outputs Cable length unshielded, max. Response threshold, typ. Limitation of inductive shutdown voltage to Lamp load, max. Controlling a digital input Output voltage for signal "1", min. 2L+ (-0.8 V) 2L+ (-1.2 V) 8 30 m 8 30 m Yes; Electronic 2L+ (-44 V) 10 W Yes Short-circuit protection 3 ms; Typ. 3 ms; typically 3 ms; Typ. 3 ms; typically Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/ alarms/diagnostics Status indicator Alarms Alarms Diagnoses Diagnostics

Yes 1.5 mA

Yes 1.5 mA

Short-circuit protection of the output Yes; Electronic 2L+ (-44 V) 10 W Yes

4 A per channel 4 A per channel

Yes No Yes; Diagnostic information readable

Yes No Yes; Diagnostic information readable

Siemens IK PI 2009

5/349

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Technical specifications (continued)


Order No. Diagnostics indication LED Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green) Channel error indicator F (red) Isolation Isolation checked with Isolation between PROFIBUS DP all all other circuits Galvanic isolation, digital inputs between the channels Isolation, digital outputs between the channels Permissible potential difference between different circuits General information Vendor identification (VendorID) Dimensions Dimensions Width Height Depth Weights Weight, approx. 210 g 210 g 60 mm 210 mm 28 mm 60 mm 210 mm 28 mm 80DCh 80FCh 75 VDC / 60 VAC 75 VDC / 60 VAC No No No No Yes Yes 500 VDC 500 VDC Yes Yes Yes No Yes Yes Yes No 6ES7 1433BH00-0XA0 6ES7 1433BH10-0XA0 Order No. Current consumption Power loss, typ. 2 W; The power loss depends on the current that you loop through via the connection block. 2 W; The power loss depends on the current that you loop through via the connection block. 6ES7 1943AA00-0AA0 6ES7 1943AA00-0BA0

Dimensions Dimensions Width Height Depth Weights Weight, approx. 313 g 392 g 79 mm 60 mm 30 mm 79 mm 60 mm 29 mm

5/350

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Ordering data
ET 200eco basic modules BM 141 8 DI 24 V DC 8 x M12, individual assignment, IP65/67 connection block 6ES7194-3AA00-0.A0 to be ordered separately 16 DI 24 V DC 8 x M12, double assignment, IP65/67 connection block 6ES7194-3AA00-0.A0 to be ordered separately ET 200eco basic module BM 142 8 DO 24 V DC/1.2 A 8 x M12, individual assignment, IP65/67 connection block 6ES7194-3AA00-0.A0 to be ordered separately 16 DO 24 V DC/0.5 A 8 x M12, double assignment, IP65/67; connection block 6ES7 194-3AA00-0.A0 to be ordered separately ET 200eco basic modules BM 143 8 DI/8 DO, 2 A 8 x M12, IP65/67 connection block 6ES7194-3AA00-0.A0 to be ordered separately 8 DI/8 DO, 1.3 A 8 x M12, double assignment, IP65/67 connection block 6ES7 194-3AA00-0.A0 to be ordered separately ET 200eco basic modules BM 148 4/8 F-DI, 8 x M12, connection block 6ES7194-3AA00-0.A0 to be ordered separately ECOFAST connection block for ET 200eco, 2 x ECOFAST connection RS485 identification connector for PROFIBUS DP, address setting M12 connection block, 7/8" for ET 200eco, 2 x M12 and 2 x 7/8" 2 rotary coding switch for PROFIBUS DP, address setting

Order No. Accessories 6ES7 141-3BF00-0XA0 "Distributed Safety" V5.4 F programming tool Floating License for 1 user, with documentation, 3 languages (German, English, French), on CD, runs on STEP 7 V5.3 SP3 or higher "Distributed Safety" F programming tool Upgrade from V5.x to V5.4 "Distributed Safety" F programming tool Software update service for 1 year, with automatic extension; latest current software version. 6ES7 142-3BH00-0XA0 Labels Module description "Distributed I/O device ET 200eco" excluding F-DI Paper copy German 6ES7 143-3BH00-0XA0 English French PROFIBUS ECOFAST Hybrid Cable Cu PROFIBUS ECOFAST terminating plug ECOFAST terminating resistor for PROFIBUS DP 1 pack = 1 unit 6ES7 148-3FA00-0XB0 1 pack = 5 units M12 covering caps 6ES7 194-3AA00-0AA0 for sealing of unused I/O sockets

Order No.

6ES7 833-1FC02-0YA5

6ES7 141-3BH00-0XA0

6ES7 833-1FC02-0YE5

6ES7 142-3BF00-0XA0

6ES7 833-1FC00-0YX2

3RT1 900-1SB20

6ES7 198-8GA00-8AA0 6ES7 198-8GA00-8BA0 6ES7 198-8GA00-8CA0 See ECOFAST bus cables

6ES7 143-3BH10-0XA0

6GK1 905-0DA10 6GK1 905-0DA00 3RX9 802-0AA00

6ES7 194-3AA00-0BA0

Siemens IK PI 2009

5/351

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200eco

Ordering data
PROFIBUS M12 connecting cable Pre-assembled 2-wire (inverse coded) with M12 connectors in various lengths up to 100 m: 0.3 m 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 5.0 m 10.0 m 15.0 m Other special lengths with 90 or 180 cable outlet

Order No. PROFIBUS M12 cable connector 1 pack = 5 units Male insert Socket insert 6XV1 830-3DE30 6XV1 830-3DE50 6XV1 830-3DH10 6XV1 830-3DH15 6XV1 830-3DH20 6XV1 830-3DH30 6XV1 830-3DH50 6XV1 830-3DN10 6XV1 830-3DN15 see http://support.automation. siemens.com/ WW/view/en/26999294 7/8" connector 1 pack = 5 units Male insert Socket insert 7/8" covering caps 1 pack = 10 units M12 Y-shaped coupler plug For double connection of sensors using single cable, 5-pin; not applicable for F-DI4/8 M12 coupler plug for connecting actuators or sensors, 5-pole M12 angular coupler plug for connecting actuators or sensors, 5-pole 6XV1 830-8AH10 S7 Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Order No.

M12 connection block, 7/8" accessories

6GK1 905-0EA00 6GK1 905-0EB00

6GK1 905-0FA00 6GK1 905-0FB00 6ES7 194-3JA00-0AA0 6ES7 194-1KA01-0XA0

3RX1 667

SIMATIC NET energy cable 5-wire energy cable, stranded 5 x 1.5 mm2, trailing-type Sold by the meter, minimum order quantity = 20 m PROFIBUS M12 connecting cable for PROFIBUS DP, 1 pack = 5 units Male insert Socket insert 7/8" connecting cable to power supply Pre-assembled 5-wire with 7/8" connectors in various lengths up to 50 m: 0.3 m 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 5.0 m 10.0 m 15.0 m Other special lengths with 90 or 180 cable outlet 6XV1 822-5BE30 6XV1 822-5BE50 6XV1 822-5BH10 6XV1 822-5BH15 6XV1 822-5BH20 6XV1 822-5BH30 6XV1 822-5BH50 6XV1 822-5BN10 6XV1 822-5BN15 see http://support.automation. siemens.com/ WW/view/en/26999294 6GK1 905-0EC00 6GK1 905-0ED00

3RX1 668

6ES7 998-8XC01-8YE0

6ES7 998-8XC01-8YE2

5/352

Siemens IK PI 2009

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200R

Overview
Distributed I/O to the degree of protection IP65 Die-cast aluminum housing Integrated repeater Parameterizable inputs/ outputs: 8 DI/8 DO up to 16 DI Terminal strip at rear for connecting up analog signals for welding transformers Connection through hybrid line to 17-pin M23 connector

Technical specifications
Order No. Supply voltages Rated value DC 24 V permissible range, upper limit (DC) Reverse polarity protection Yes; -15 / +20 % Yes; -15 / +20 % 20.4 V 28.8 V Yes; Also electronic protection 28.8 V Yes; Also electronic protection permissible range, lower limit (DC) 20.4 V 6ES7 1432BH00-0AB0 6ES7 1432BH50-0AB0 Order No. Input voltage for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs - at "0" to "1", max. Digital outputs Number of digital outputs 8; 16 process channels, 8 DI fixed, 8 DI/DO parameterizable 10 m 8; 16 process channels, 8 DI fixed, 8 DI/DO parameterizable 10 m Yes; Electronic 0.5 A 3 ms; Typ. 3 ms; Typ. 7 mA 7 mA -3 to +5 V -3 to +5 V 15 to 30 V 6ES7 1432BH00-0AB0 6ES7 1432BH50-0AB0

Connection point Bus cables Bus and voltBus and voltage: X01/X02: age: X01/X02: 2x M23 (17-pin) 2x M23 (17-pin) 8x 5-pin M12x1 circular connector Yes; Ramp-up time at 12 Mbit/s: approx. 80 ms 30 m; Per line, shielded 8; 16 process channels, 8 DI fixed, 8 DI/DO parameterizable 10 m; for signal lines Yes 8x 5-pin M12x1 circular connector

Inputs/outputs

Protocols PROFIBUS DP protocol Yes

Cable length unshielded, max. Output current for signal "1" permissible range for 0 to 55 C, max. 30 m; Per line, shielded 8; 16 process channels, 8 DI fixed, 8 DI/DO parameterizable 10 m; for signal lines Yes Encoder Connectable encoders 2-wire BEROS Switching frequency with resistive load, max. Aggregate current of the outputs (per group) up to 55 C, max. Encoder supply Number of outputs Output current, rated value

Short-circuit protection of the output Yes; Electronic 0.5 A

PROFIBUS DP Cable length, max. Digital inputs Number of digital inputs

100 Hz

100 Hz

2A 8 0.5 A; 8 channels each

2A 8 0.5 A; 8 channels each

Cable length Cable length unshielded, max. Input characteristic curve to IEC 1131, Typ 2

Yes

Yes

Siemens IK PI 2009

5/353

Siemens AG 2008

SIMATIC ET 200 distributed I/Os


ET 200R

Technical specifications (continued)


Order No. Status information/ alarms/diagnostics Diagnoses Diagnostic functions Short circuit Yes; Diagnostics frames Yes; (Digital outputs) per group; X0 to X1 or X2 to X3 Yes; per group X0 to X3 or X4 to X7 Yes Channel 01, Channel 02 Yes Yes; 24 V DC (load voltage) US2 Yes Yes Yes Yes; Diagnostics frames Yes; (Digital outputs) per group; X0 to X1 or X2 to X3 Yes; per group X0 to X3 or X4 to X7 Yes 6ES7 1432BH00-0AB0 6ES7 1432BH50-0AB0

Ordering data
ET 200R handling module IP65 Metal casing 8 DI + 8 DI/DO, configurable; 24 V DC, 5-pole, 8 x M12, 2 x M23 (DP, PS, analog) ET 200R welding module IP65 Metal casing 8 DI + 8 DI/DO, configurable; 24 V DC, 5-pole, 8 x M12, 2 x M23 (DP, PS, analog) Accessories Cables ELOCAB

Order No. 6ES7 143-2BH00-0AB0

6ES7 143-2BH50-0AB0

Short circuit encoder supply

missing load voltage Diagnostics indication LED Description Bus error BF (red)

Order from: ELOCAB Sonderkabel Obere Lerch 34 D-91166 Georgensmnd Tel.: (0 91 72) 69 80-0 Fax: (0 91 72) 20 29 Order from: Hypertac GmbH Auwiesenstr. 5, Postfach 14 65 D-94454 Deggendorf 6ES7 998-8XC01-8YE0

Connector Interconnectron M23 Channel 01, Channel 02 Yes Yes; 24 V DC (load voltage) US2 Yes Yes Yes Yes; (Logic circuits/ encoder voltage) US1 S7 Manual Collection Electronic manuals on DVD, multi-language: S7-200, TD 200, S7-300, M7-300, C7, S7-400, M7-400, STEP 7, Engineering Tools, Runtime Software, SIMATIC DP (Distributed I/O), SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication) S7 Manual Collection update service for 1 year Scope of delivery: Current DVD "S7 Manual Collection" and the three subsequent updates

Rated load voltage PWR (green)

Collective error SF (red) Status indicator digital output (green) Status indicator digital input (green)

Monitoring 24 V voltage supply ON Yes; (Logic circuits/ (green) encoder voltage) US1 Environmental requirements Operating termperature max. Degree and class of protection IP 65 Standards, approvals, certificates CE symbol CSA approval UL Approval General information Housing Dimensions Dimensions Width Height 54 mm 55 mm; 64 mm incl. overall plug height 150 mm 780 g Die-cast aluminum Yes Yes; ES 02 or higher Yes; ES 02 or higher Yes 55 C

6ES7 998-8XC01-8YE2

55 C Yes Yes Yes Yes

Die-cast aluminum

54 mm 55 mm; 64 mm incl. overall plug height 150 mm 780 g

Length Weights Weight, approx.

7
5/354
Siemens IK PI 2009

S-ar putea să vă placă și