Sunteți pe pagina 1din 59

RAN10.

0 3900 Series NodeB

Product Description

Issue Date

03 2008-09-18

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email: http://www.huawei.com support@huawei.com

Copyright Huawei Technologies Co., Ltd. 2008. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.

RAN10.0 3900 Series NodeB Product Description

Contents
1 Introduction .....................................................................................................................6
1.1 3900 Series NodeBs ........................................................................................................................ 6 1.2 Product Features.............................................................................................................................. 7

2 System Architecture .......................................................................................................9


2.1 Product Overview ............................................................................................................................. 9 2.2 BBU3900 .......................................................................................................................................... 9 2.2.1 Physical Structure of the BBU3900 ......................................................................................... 9 2.2.2 Hardware Units of the BBU3900 ........................................................................................... 10 2.2.3 Ports on the BBU3900........................................................................................................... 10 2.3 RRU.................................................................................................................................................11 2.3.1 Specifications of the RRU.......................................................................................................11 2.3.2 Physical Structure of the RRU ............................................................................................... 12 2.3.3 Ports on the RRU .................................................................................................................. 13 2.4 WRFU............................................................................................................................................. 14 2.4.1 Specifications of the WRFU................................................................................................... 14 2.4.2 Physical Structure of the WRFU............................................................................................ 14 2.4.3 Ports on the WRFU ............................................................................................................... 15 2.5 Auxiliary Devices ............................................................................................................................ 15 2.5.1 APM ....................................................................................................................................... 15 2.5.2 Indoor Macro Cabinet ............................................................................................................ 18 2.5.3 Outdoor RF Cabinet .............................................................................................................. 20 2.5.4 Outdoor Mini Cabinet............................................................................................................. 21

3 Products and Application Scenarios...........................................................................23


3.1 Distributed NodeBDBS3900 ....................................................................................................... 23 3.1.1 Integrated Application ............................................................................................................ 23 3.1.2 Embedded Application with Existing Site Equipment ............................................................ 24 3.1.3 Outdoor BBU Application....................................................................................................... 24 3.2 Indoor Macro NodeBBTS3900 ................................................................................................... 25 3.3 Outdoor Macro NodeBBTS3900A .............................................................................................. 26 3.4 Outdoor Mini NodeBBTS3900C ................................................................................................. 28 3.5 Multi-Mode Base Station ................................................................................................................ 30

4 Features.........................................................................................................................31
4.1 Advanced Platform Structure.......................................................................................................... 31 4.2 High Integrity and Large Capacity.................................................................................................. 31

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 4 of 59

RAN10.0 3900 Series NodeB Product Description 4.3 High Performance .......................................................................................................................... 31 4.4 ATM/IP Dual Stack.......................................................................................................................... 32 4.4.1 ATM........................................................................................................................................ 32 4.4.2 IP ........................................................................................................................................... 32 4.5 Multiple Clock and Synchronization Modes ................................................................................... 33 4.6 HSDPA Services............................................................................................................................. 33 4.7 HSUPA Services............................................................................................................................. 33 4.8 MBMS............................................................................................................................................. 33 4.9 High-Velocity UE Access................................................................................................................ 34 4.10 Antenna Enhancement Technology.............................................................................................. 34 4.11 Same Band Antenna Sharing ....................................................................................................... 34 4.12 OM Platforms ............................................................................................................................... 35 4.13 Environment Adaptability.............................................................................................................. 35 4.14 Capacity Expansion Evolution...................................................................................................... 36

5 Operation and Maintenance.........................................................................................37


5.1 Overview ........................................................................................................................................ 37 5.2 OM Functions ................................................................................................................................. 38 5.2.1 Security Management............................................................................................................ 38 5.2.2 Equipment Management ....................................................................................................... 38 5.2.3 Fault Management................................................................................................................. 38 5.2.4 Software Management .......................................................................................................... 38 5.2.5 Performance Management .................................................................................................... 39 5.2.6 Commissioning Management ................................................................................................ 39 5.2.7 Environment Monitoring......................................................................................................... 39 5.2.8 License Management ............................................................................................................ 39 5.2.9 Task Management ................................................................................................................. 39

6 Reliability.......................................................................................................................41
6.1 Overview ........................................................................................................................................ 41 6.2 System Reliability ........................................................................................................................... 41 6.3 Hardware Reliability ....................................................................................................................... 42 6.4 Software Reliability......................................................................................................................... 42

7 Technical Specifications ..............................................................................................44


7.1 Technical Specifications of the BTS3900 ....................................................................................... 44 7.2 Technical Specifications of the BTS3900A..................................................................................... 46 7.3 Technical Specifications of the DBS3900....................................................................................... 49 7.4 Technical specifications of the BTS3900C ..................................................................................... 55

8 Acronyms and Abbreviations ......................................................................................59

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 5 of 59

RAN10.0 3900 Series NodeB Product Description

1
1.1 3900 Series NodeBs

Introduction

The mobile communications, which takes an ever-changing presence with each passing day, blazes a trail for the upgrade of technologies and products. The growing trend of mobile communications comprises a series of evolution, from GSM to EDGE to EDGE+ and from WCDMA to HSPA to HSPA+ and LTE, and it is worth mentioning that WiMAX also joins the 3G family. To follow the trend, the network operators have to devote more CAPEX and OPEX to the dramatic change of technologies, and therefore they are currently focusing on the merge of multiple network systems into a more cost-effective one. Upon the transition of mobile networks, the network operators target at the Blue Ocean Strategy and invite innovative and responsive partners. Customer-oriented and innovative, Huawei advocates four basic technological concepts: green, merge, wideband, and evolution. Huawei will take the lead in developing the next-generation base stations and the 3900 series NodeBs, Huawei's fourth generation base stations, will outclass other base stations to benefit operators with future-oriented networks. Huawei unveils cutting-edge techniques in the 3900 series NodeBs, such as wideband, multi-mode system, and modular design. The 3900 series NodeBs consist of only three basic functional modules, characterized by compact structure, high integration, low power consumption, and easy and quick deployment. Flexible combinations of functional modules and auxiliary devices encourage Huawei to diversify the products. More importantly, the modules for different modes of systems can be installed in one cabinet to work as a base station adapting to different scenarios. Huawei also actively introduces new frequency bands and technologies to well meet operators' requirement for a compact multi-mode mobile network system. Figure 1-1 shows the basic functional modules and auxiliary devices of the 3900 series NodeBs.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 6 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 1-1 Basic functional modules and auxiliary devices

1.2 Product Features


Adaptable to diversified radio environments Different combinations of functional modules and auxiliary devices diversify the NodeB products. For example, there are macro NodeB, distributed NodeB, and mini compact NodeB, which operate in different scenarios to better meet different network deployment requirements. The 3900 series NodeBs provide a platform for the Huawei wireless products. To be specific, the base stations of different network systems such as GSM, WCDMA, CDMA, and WiMAX can share the same cabinet or even share one functional module at the same frequency band (based on the SDR technology), which makes it easy for network operators to choose a site type. Greatly reduced Total Cost of Operation (TCO) The 3900 series NodeBs have many advantages, such as flexible installation, easy site selection, cost-effective solution, and fast network construction. The baseband module (BBU3900) is only 19 inches wide and 2 U high, taking a very small indoor space or taking a place in an outdoor cabinet. The RF module (RRU3900) can be installed close to the antenna without taking any space of the equipment room. The RRU3804 supports up to four carriers with an output power of 60 W, known as the highest output power of the RRU in the telecom industry. The outstanding performance ensures wide coverage and high throughput. When two carriers are configured for the RRU3804, the number of sites can be reduced by 40%.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 7 of 59

RAN10.0 3900 Series NodeB Product Description

The 3900 series NodeBs use the high-efficiency digital Power Amplifier (PA), which greatly reduces power consumption and helps build a green communication network. Compared with the traditional NodeB, the macro NodeB (BTS3900) has its power consumption reduced by 30%; compared with the traditional macro NodeB, the BTS3900A cabinet, which is in direct-ventilation, has its power consumption reduced by 40%. Based on the IP switch and multi-carrier technologies, the 3900 series NodeBs support the bandwidth of over 100 Mbit/s, which keeps up with the fast growing mobile data services and provides users with higher data transmission rate. Smooth evolution to future radio network systems The 3900 series NodeBs support smooth evolution to HSPA+ and Long Term Evolution (LTE), thus fully protecting the investment of network operators.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 8 of 59

RAN10.0 3900 Series NodeB Product Description

2
2.1 Product Overview
APM30 power cabinet Indoor macro cabinet Outdoor cabinet Outdoor mini cabinet

System Architecture

The 3900 series NodeBs feature a modular design. The basic functional modules are the baseband unit (BBU3900) and the indoor RF unit (WRFU), and outdoor remote RF unit (RRU). The BBU is connected to the RRU or WRFU through CPRI ports and optical cables. The auxiliary devices for the BTS3900 are as follows:

The variable combinations of functional modules and auxiliary devices provide flexible site solutions for different scenarios.

2.2 BBU3900
2.2.1 Physical Structure of the BBU3900
The BBU3900 is a compact case structure that requires a 19-inch-wide and 2-U-high space. It can be installed on a wall, on the staircase, in the storeroom, or in an outdoor cabinet on the existing network. It can be also installed in an outdoor cabinet of the existing network. Figure 2-1 shows the physical structure of the BBU3900. Figure 2-1 Physical structure of the BBU3900

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 9 of 59

RAN10.0 3900 Series NodeB Product Description

2.2.2 Hardware Units of the BBU3900


Basic Hardware Units
The basic hardware units of the BBU3900 are as follows: WCDMA Main Processing Transmission (WMPT) unit WCDMA BaseBand Processing (WBBP) unit Universal Fan (UFAN) unit Power module All the boards support the plug-and-play function and can be configured in the slot as required.

Optional Hardware Units


The optional hardware units of the BBU3900 are as follows: Universal E1/T1 Lightning Protection (UELP) unit Universal FE Lightning Protection (UFLP) unit Universal Satellite card and Clock Unit (USCU) Universal Transmission Processing (UTRP) unit Universal Environment Interface Unit (UEIU) The BBU3900 supports diverse configurations from 1 x 1 to 6 x 4 or 3 x 8.

2.2.3 Ports on the BBU3900


Table 2-1 Ports on the basic hardware units of the BBU3900 Board
WMPT

Port
E1 port FE electrical port FE optical port USB port for loading USB port for test Serial port for commissioning GPS port

Quantity
1 1 1 1 1 1 1 3 1 1 1

Connector Type
DB26 connector RJ45 connector SFP connector USB connector USB connector RJ45 connector SMA connector SFP connector 3V3 connector RJ45 connector RJ45 connector

Remarks
One port supporting four E1s Software loading Test port NodeB local maintenance 48 V DC power input and +24 V DC power input Providing two RS485 monitoring ports; connecting to the external monitoring device

WBBP UPEU

CPRI PWR MON0 MON1

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 10 of 59

RAN10.0 3900 Series NodeB Product Description

Board
UPEU

Port
EXT-ALM0 EXT-ALM1

Quantity
1 1

Connector Type
RJ45 connector RJ45 connector

Remarks
Providing eight dry contact alarm inputs; connecting to the external alarm device

Table 2-2 Ports on the optional hardware units of the BBU3900 Board
UELP

Port
INSIDE OUTSIDE

Quantity
1 1 2 2

Connector Type
DB25 connector DB26 connector RJ45 connector RJ45 connector

Remarks
Port for four E1/T1 signal inputs Port for four E1/T1 signal outputs Connecting to the NodeB Connecting to the external device. The FE0 (OUTSIDE) connects to the FE0 (INSIDE) and the FE1 (OUTSIDE) connects to the FE1 (INSIDE). Connecting to the RGPS signal cable Connecting to the BITS clock Port for testing clock signal output RF signal input port of the satellite card Providing eight ATM over E1s/T1s or eight IP over E1s/T1s Connecting to external monitoring devices

UFLP

FE0 and FE1 (INSIDE) FE0 and FE1 (OUTSIDE)

USCU

RGPS port BITS port Clock test port Antenna port for the satellite card

3 1 1 1 2 1 1 1 1

DB8 connector SMA connector SMA connector SMA connector DB26 connector RJ45 connector RJ45 connector RJ45 connector RJ45 connector

UTRP UEIU

E1/T1 port MON MON1 EXT-ALM0 EXT-ALM1

Connecting to external alarm devices

The UEIU is a monitoring and dry contact extension board for the UPEU.

2.3 RRU
2.3.1 Specifications of the RRU
The RRU is the outdoor RF remote unit that can be installed close to the antenna. The RRU is classified into RRU3804 and RRU3801C based on different output power and

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 11 of 59

RAN10.0 3900 Series NodeB Product Description

processing capabilities. Table 2-3 describes the specifications of the RRU3804 and the RRU3801C. Table 2-3 Specifications of the RRU3801C and the RRU3804 RRU Type Maximum Output Power Number of Carriers Supported
RRU3801C 40 W 2 RRU3804 40 W 4

2.3.2 Physical Structure of the RRU


The BBU3900, together with either the RRU3801C or the RRU3804, can form the DBS3900 system. The RRU3801C and the RRU3804 have the same physical structure, as shown in Figure 2-2. Figure 2-2 Physical structure of the RRU

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 12 of 59

RAN10.0 3900 Series NodeB Product Description

2.3.3 Ports on the RRU


The ports of the RRU are located at the bottom of the module and in the cabling cavity. The RRU has the following ports: Grounding ports Power input ports Transmission ports Alarm ports Table 2-4 Ports on the RRU3801C Port
Power input port

Connector Type
9-pin, round, and waterproof connector ESFP socket DB15 connector (shared by the fan) DIN, round, and waterproof connector DIN, round, and waterproof connector 2W2 connector

Quantity
1

Remarks
Ports for 48 V DC or 220 V AC power input Transmission ports Alarm port Other ports

Optical ports Port for 4-channel dry contact alarms Main TX/RX port

2 1 1

RX diversity port

Port for interconnection between combined modules Port for the RET antenna Commissioning port

DB9 connector RJ45 connector

1 1

Table 2-5 Ports on the RRU3804 Port


Power input port Optical ports Port for 2-channel dry contact alarms and port for 1-channel RS485 signals Main TX/RX port

Connector Type
OT terminal ESFP socket DB15 connector (shared by the fan) DIN, round, and waterproof connector

Quantity
1 2 1

Remarks
Port for 48 V DC power input Transmission ports Alarm port

Other ports 1

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 13 of 59

RAN10.0 3900 Series NodeB Product Description

Port
RX diversity port

Connector Type
DIN, round, and waterproof connector 2W2 connector

Quantity
1

Remarks

Port for interconnection between combined modules

2.4 WRFU
2.4.1 Specifications of the WRFU
The WRFU is categorized into 40 W WRFU and 80 W WRFU based on different output power and processing capabilities. The 40 W WRFU and 80 W WRFU have the same physical structure, dimensions, weight, and physical ports. Table 2-6 Specifications of the WRFU WRFU Type Maximum Output Power Number of Carriers Supported
80 W WRFU 80 W 4 40 W WRFU 40 W 2

2.4.2 Physical Structure of the WRFU


The WRFU can be housed in an indoor cabinet or an outdoor cabinet. Figure 2-3 shows the physical structure of the WRFU. Figure 2-3 Physical structure of the WRFU

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 14 of 59

RAN10.0 3900 Series NodeB Product Description

2.4.3 Ports on the WRFU


Table 2-7 Ports on the WRFU Port
Power port Port for transceiving antenna signals CPRI ports Ports for transmitting diversity RX signals Commissioning port

Connector Type
3V3 connector N female connector SFP female connector QMA female connector RJ45 connector

Quantity
1 2 2 2 1

Remarks
Port for 48 V DC input power

Port for connecting the antenna system Ports for connecting the BBU Ports for cascading WRFUs Commissioning port

2.5 Auxiliary Devices


2.5.1 APM
The Advanced Power Module (APM), an outdoor power backup system that provides 48 V DC power and backup power for the distributed NodeBs, outdoor macro NodeBs, and mini NodeBs. In addition, it provides installation space for the BBU3900 and other devices. The APM is categorized into APM30 and APM100. The APM30 features a compact and lightweight design. It can be installed on a pole or on the ground. The 12 Ah, 24 Ah, and 36 Ah batteries can be installed in the APM30 cabinet. The APM100 can be installed on the ground. The 50 Ah or 100 Ah batteries can be configured in the APM100. The APM30 contains the following units: Power Supply Unit (PSU) Power Monitoring Unit (PMU) Power Distribution Unit (PDU) APM Power unit Interface Board (APMI) Temperature monitoring unit 24 Ah batteries Figure 2-4 shows the internal structure of the APM30 and Figure 2-12 shows that of the APM100.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 15 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 2-4 Internal structure of the APM30

Figure 2-5 Internal structure of the APM100

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 16 of 59

RAN10.0 3900 Series NodeB Product Description

Table 2-8 Technical specifications of the APM Item


Engineering specifications Dimensions (width x height x depth) (with the base excluded) Weight (with batteries and user equipment excluded) Working temperature

APM30 Specification
600 mm 700 mm 480 mm

APM100 Specification
600 mm x 1130 mm x 600 mm

< 65 kg

88 kg

-40C to +45C (with 1120 W/m2 solar radiation) 40C to +50C (without solar radiation) When the ambient temperature is lower than 20 an AC heater is C, required.

Northern type: 40C to +45C Southern type: 5C to +45C

AC input

Input voltage

Rated voltage: 200 V AC to 240 V AC Permissible voltage range: 176 V AC to 290 V AC Rated voltage: 100/200 V AC to 120/240 V AC
Permissible voltage range: 90/180 V AC to 135/270

Rated voltage: 120/208 V AC to 127/220 V AC


Permissible voltage range: 105/176 V AC to 150/260 V AC Frequency of the rated voltage Frequency of input voltage DC output Output voltage range DC outputs 50/60 Hz 45 Hz to 65 Hz 58 V DC to 44 V DC Working with the distributed NodeB: LLVD: 20 A x 6 BLVD: 12 A x 2; 4 A x 2 Maximum outputs (reserved): 4 A x 2 Working with the separated NodeB: LLVD: 30 A x 4 BLVD: 12 A x 2; 4 A x 4 Maximum outputs (reserved): 4 A x 4 Space for user equipment 48 V 24 Ah built-in batteries No built-in batteries 5U 7U 16 A x 4: 4 outputs 32 A x 2: 2 outputs 40 Hz to 65 Hz

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 17 of 59

RAN10.0 3900 Series NodeB Product Description

Item
48 V 100 Ah built-in batteries

APM30 Specification

APM100 Specification

2.5.2 Indoor Macro Cabinet


The indoor macro cabinet houses the BBU3900 and the WRFU. In addition, the indoor macro cabinet provides functions such as power distribution and surge protection. The indoor macro cabinet takes a small footprint and is easy to install. In addition, two cabinets can be installed in stack mode. All these features cater to the requirements of indoor centralized installation and fast network construction. An indoor macro cabinet accommodates up to six WRFUs. The indoor macro cabinet supports all the network systems (UMTS, GSM, and LTE) of the BTS3900, thus saving installation space and facilitating smooth evolution. The indoor macro cabinet supports 48 V DC, +24 V DC, and 220 V AC power inputs. If configured with suitable power modules, the +24 V DC or 220 V AC power is converted into 48 V DC power for the WRFU and BBU.

When two cabinets are installed in stack mode, the upper cabinet should be a -48 V DC cabinet, and the lower cabinet can be either a +24 V DC cabinet or a 220 V AC cabinet, depending on power configuration.

The cabinet structure varies with the power input. Figure 2-6 shows the single indoor cabinet with 48 V DC power. Figure 2-7 shows the single indoor cabinet with +24 V DC power. Figure 2-8 shows the single indoor cabinet with 220 V AC power. Figure 2-9 shows two cabinets in stack mode. Figure 2-6 Single indoor cabinet (48 V)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 18 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 2-7 Single indoor cabinet (+24 V)

Figure 2-8 Single indoor cabinet (220 V)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 19 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 2-9 Two indoor cabinets in stack mode

2.5.3 Outdoor RF Cabinet


The outdoor RF cabinet, together with the APM30 cabinet in stack mode, performs functions such as power distribution, surge protection, and for the WRFU and the BBU3900.The outdoor RF cabinet works in direct-ventilation mode to dissipate heat. When the RF cabinet is configured with three WRFUs, 50 Ah or 100 Ah batteries can be installed in the spare space, as shown in Figure 2-10. When the RF cabinet is configured with six WRFUs, there is no space for the batteries, as shown in Figure 2-11.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 20 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 2-10 Outdoor RF cabinet with three WRFUs

Figure 2-11 Outdoor RF cabinet with six WRFUs

2.5.4 Outdoor Mini Cabinet


The outdoor mini cabinet performs functions such as power distribution and surge protection for the BBU3900. The BBU3900 can be installed in an outdoor mini cabinet to work as an outdoor BBU, thus achieving the outdoor application of the compact mini NodeB. The outdoor mini cabinet has a built-in heat exchanger. If the AC power is used, the cabinet must be configured with an EPS30-4815A and an SPD (AC); if the DC power is used, the cabinet must be configured with a DC power distribution box, as shown in Figure 2-12.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 21 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 2-12 Internal structure of the outdoor mini cabinet

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 22 of 59

RAN10.0 3900 Series NodeB Product Description

Products and Application Scenarios

3.1 Distributed NodeBDBS3900


As demand for environmental protection as well as lease cost has increased, the site selection has become a bottleneck in network deployment. It is increasingly difficult to adopt 2G/3G co-siting or to select a new site. The distributed NodeB (DBS3900) developed by Huawei features high integration, easy installation, and low power consumption. All these features can facilitate site reselection and 2G/3G co-siting. In addition, the WRRU can be installed close to the antenna. In this way, the feeder consumption is reduced and system coverage is improved.

3.1.1 Integrated Application


If only the AC power is available at a new outdoor 3G site and power backup device is required, the combination of DBS3900 and APM can function as an outdoor macro NodeB. Figure 3-1 shows the typical configuration of DBS3900 + APM. This configuration has the following features: The BBU3900 and transmission equipment can be installed in the APM cabinet and the RRU can be installed close to the antenna. The APM provides installation space and outdoor protection for the BBU3900 and supplies 48 V DC power to the BBU3900 and the WRRU. In addition, the APM manages and monitors the batteries and provides surge protection for the batteries. The APM30 can be configured with 12 Ah, 24 Ah, or 36 Ah built-in batteries and the APM100 can be configured with 50 Ah or 100 Ah built-in batteries. Whether the APM30 or the APM100 should be used depends on the required power back period.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 23 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-1 DBS3900 + APM

3.1.2 Embedded Application with Existing Site Equipment


For the 2G/3G co-siting scenario, the BBU3900 can be installed in a standard 19-inch-wide and 2-U-high cabinet, and the WRRU can be installed close to the antenna, as shown in Figure 3-2. The BBU3900 and the WRRU can share the power backup system, transmission system, and antenna system of the BTS in the 2G network. In this way, operators can launch 3G services on the existing 2G network at a very low cost. Figure 3-2 Embedded application based on existing site equipment

3.1.3 Outdoor BBU Application


For the 2G/3G co-siting scenario, the BBU3900 can be installed in the outdoor mini cabinet to function as an outdoor BBU. The WRRU can be installed close to the antenna for easy and quick deployment, as shown in Figure 3-3.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 24 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-3 Outdoor BBU application

3.2 Indoor Macro NodeBBTS3900


The BTS3900, as shown in Figure 3-4, is applicable to indoor scenarios such as centralized installation and relocation. The BTS3900, as one of the most compact indoor macro NodeBs in the telecommunication industry, boasts large capacity and sound scalability. It has a small footprint and supports the GSM and WCDMA dual-mode application.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 25 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-4 Indoor cabinet macro NodeB

3.3 Outdoor Macro NodeBBTS3900A


The BTS3900A is applicable to the outdoor scenarios such as centralized installation and replacement of the macro NodeB. The BTS3900A consists of the outdoor RF cabinet and the APM30 that are installed in stack mode. The BBU3900 is installed in the APM30, and the WRFU is installed in the RF cabinet. Configurations of the BTS3900A vary with different application scenarios, as shown in Figure 3-5 and Figure 3-6. As the most compact outdoor cabinet macro NodeB in the industry, features light weight and easy transportation due to its stacking design. The RF modules in GSM, UMTS, and LTE modes can share one RF cabinet, which saves installation space and facilitates smooth evolution.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 26 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-5 Cabinet macro NodeB (1)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 27 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-6 Cabinet macro NodeB (2)

3.4 Outdoor Mini NodeBBTS3900C


The BTS3900C applies to the new outdoor 3G site environments such as tunnels, hot spots, places without equipment rooms, and marginal networks. The BTS3900C supports 48 V DC power and 220 V AC power. If 48 V DC power is used, the mini cabinet must be configured with a DC power distribution box, as shown in Figure 3-7. If 220 V AC power is used, the mini cabinet must be configured with an EPS30-4815A and an SPD (AC), as shown in Figure 3-8. The BTS3900C can be installed on the pole, against the wall, or on the ground. The stand or support of other types can be applied to the installation of the BTS3900C on the ground.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 28 of 59

RAN10.0 3900 Series NodeB Product Description

Figure 3-7 Outdoor mini NodeB with 48 V DC power

Figure 3-8 Outdoor mini NodeB with 220 V AC power

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 29 of 59

RAN10.0 3900 Series NodeB Product Description

3.5 Multi-Mode Base Station


The 3900 series NodeBs feature a unified platform and a modular design. Therefore, co-siting of modules in GSM, UMTS, or LTE mode can be supported, the baseband processing units and RF modules can share the same hardware platform, and modules in different modes can be located in one cabinet to support multi-mode application. This helps implement smooth evolution from GSM to UMTS or LTE. With baseband modules for different modes configured in one cabinet, the base station can support the GSM only mode, UMTS only mode, or GSM/UMTS dual mode. In addition, with the baseband modules for LTE mode configured in the future, the base station can support the GSM/UMTS/LTE multi-mode application. With RF modules for different modes configured in one cabinet, the base station can support the GSM only mode, UMTS only mode, or GSM/UMTS dual mode. The RF modules in UMTS mode are LTE-ready in hardware. Thus the base station can support UMTS/LTE dual-mode through software upgrade in the same frequency band. Figure 3-9 and Figure 3-10 show the multi-mode base stations for indoor and outdoor application respectively. Figure 3-9 Multi-mode base station for indoor application

Figure 3-10 Multi-mode base station for outdoor application

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 30 of 59

RAN10.0 3900 Series NodeB Product Description

4
4.1 Advanced Platform Structure

Features

The advanced platform structure of the 3900 series NodeBs is described as follows: The 3900 series NodeBs that adopt the IP switch-based Huawei platform support the GU co-cabinet application, HSPA+, and smooth evolution to LTE. The 3900 series NodeBs introduce the module-sharing concept, that is, the distributed NodeB, cabinet macro NodeB, and compact mini NodeB share all baseband and RF modules. The three types of basic modules form different NodeB products that apply to different scenarios, thus lowering CAPEX and OPEX. The dual-star GE IP switch technology enables exchange of large amount of internal data and satisfies more data traffic needs for HSPA+ and LTE in the future. The hot-swappable BBU3900 provides eight slots for boards and supports smooth capacity expansion and evolution. The combination of the duplexer and Transceiver Unit (TRU) in the RF module enhances the integrity of RF parts and meets the future requirements of the minimized, high-efficiency, and low-cost NodeBs. A minimized NodeB cabinet is easy to carry and install, and the stacked NodeB cabinets take up a small footprint.

4.2 High Integrity and Large Capacity


The 3900 series NodeBs are highly integrated and large in capacity: The BBU3900 contains highly integrated chips and features large capacity. A single BBU3900 supports 24 cells, with 1,536 UL CEs and 1,536 DL CEs. It also supports HSDPA and HSUPA services. A single RRU3804 or WRFU supports the 4-carrier configuration. When the NodeB evolves from 1 x 1 to 1 x 4 or from 3 x 1 to 3 x 4, no extra RRU or WRFU is required.

4.3 High Performance


The high performance of the 3900 series NodeBs are described as follows:

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 31 of 59

RAN10.0 3900 Series NodeB Product Description

The 3900 series NodeBs feature high receiver sensitivity. The 2-way receiver sensitivity is higher than 129.3 dBm without the Tower Amplification (TMA). The WRFU supports 80 W output power and the RRU3804 supports 60 W output power, which means that the PAs of the 3900 series NodeBs increase to 40%. The 3900 series NodeBs support open-loop TX diversity and closed-loop TX diversity to enhance downlink coverage and capacity. A single RRU3804 (with an SRXU) supports 4-way RX diversity to enhance antenna receiver sensitivity.

4.4 ATM/IP Dual Stack


4.4.1 ATM
In ATM transmission, the 3900 series NodeBs support the following modes: User-Network Interface (UNI) mode when transmission resources are inadequate and traffic is low. Inverse Multiplexing on ATM (IMA) mode when there are rich transmission resources. This mode features high reliability, high-speed transmission, and low latency. Fractional ATM

4.4.2 IP
The IP transmission, based on IPs, supports the transmission of various data services on low-rate links. In this mode, the IP transmission resources are fully utilized and operators' investment is greatly reduced. In IP transmission, the 3900 series NodeBs support the following technologies: Native IP transmission that requires no additional hardware. Compared with the PWE3 technology, Native IP is more efficient, cost-effective, and independent of PWE3 external devices. IP over E1, to fully utilize the E1 resources of the existing network and to offer a complete solution of IP transmission Fractional Point-to-Point Protocol (PPP) ATM and IP dual stack, to protect operators' early investment in ATM transmission Compression and multiplexing technology, namely the multiplexing of PPP header compression, PPPMUX, and IPHC, to raise the transmission rate over E1 ports. With the technology of IPHC + PPP compression + PPPMUX, the E1 transmission rate of the 12.2 kbit/s voice service rises by up to 37%. FP Multiplex (MUX), to reduce the number of Medium Access Control (MAC) headers by multiplexing packets and to raise the transmission rate over FE ports. With this technology, the FE transmission rate of the 12.2 kbit/s voice service rises by up to 40%. Hybrid transmission, which enables services to meet different QoS requirements and then to allocate different transmission paths. For example, hybrid transmission enables real-time services to travel on electrical ports, such as E1/T1 ports, and non-real-time services to travel on Ethernet ports.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 32 of 59

RAN10.0 3900 Series NodeB Product Description

4.5 Multiple Clock and Synchronization Modes


The 3900 series NodeBs support multiple clock and synchronization modes to fulfill different clock networking requirements: The upper-level clock is extracted from the Iub interface and is set by default. The 3900 series NodeBs adopt the GPS to achieve clock synchronization. The external clock synchronization refers to the 2 MHz clock on the transmission equipment. Without additional hardware, the system supports the IP clock through software upgrade, which provides a high-performance and low-cost clock solution for the IP transmission. The internal clock, an internal stratum-3 clock, ensures that the NodeB without the external clock still works properly for at least 90 days.

4.6 HSDPA Services


The 3900 series NodeBs support HSDPA services in the following aspects: One carrier supports both HSDPA and R99/R4 services. The peak downlink rate of a single UE is up to 14.4 Mbit/s. A single cell supports up to 15 HS-PDSCH codes and dynamic code resource allocation. The 3900 series NodeBs support all 12 UE categories and rates. A single cell supports 64 HSDPA subscribers. The 3900 series NodeBs support dynamic power allocation. The 3900 series NodeBs support QPSK and 16QAM to enhance spectrum utilization.

4.7 HSUPA Services


The 3900 series NodeBs support HSUPA services in the following aspects: One carrier supports both HSUPA and R99/R4 services. The 3900 series NodeBs support E-DCH TTI of 10 ms and 2 ms. The peak uplink data rate of an HSUPA subscriber is up to 5.76 Mbit/s. A single cell supports 60 HSUPA subscribers. The 3900 series NodeBs support 2 ms Received Total Wideband Power (RTWP) fast measurement to enhance the reliability of uplink load.

4.8 MBMS
The 3900 series NodeBs support the Multimedia Broadcast and Multicast Service (MBMS) in the following aspects:

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 33 of 59

RAN10.0 3900 Series NodeB Product Description

The 3900 series NodeBs support the setup, reconfiguration, and deletion of the MBMS notification Indicator Channel (MICH), and handle related signaling configuration. Each cell supports 16 Secondary Common Control Physical Channels (SCCPCHs). Each SCCPCH supports 4 Forward Access Channels (FACHs). Each cell supports 63 MBMS channels.

4.9 High-Velocity UE Access


The 3900 series NodeBs support a moving speed of up to 400 km/h. With this feature, UEs on high-speed vehicles, such as express railways and maglev trains, can still communicate properly.

4.10 Antenna Enhancement Technology


The antenna enhancement technology enables the 3900 series NodeBs to perform the following functions: Supporting the RET antenna to optimize network coverage, reduce interference, and enlarge system capacity Supporting remote batch OM, batch software upgrade, and batch RET tilt adjustment Supporting automatic scanning of the RET antenna Supporting the Antenna Interface Standard Group (AISG) 1.1 and AISG 2.0 standard interfaces Supporting the cascading of RET antennas and controlling the tilt of the 2G RET antenna through the 3G site

4.11 Same Band Antenna Sharing


To implement the same band antenna sharing with low insertion loss, the Same-band Antenna Sharing Unit (SASU) and Same-band Antenna Sharing Adapter (SASA) are introduced to reduce costs of network deployment. The SASU applies to two scenarios, namely the antenna shared by 2G and 3G systems and the antenna shared by two 3G systems. The SASU that enables two different systems at the same band to share one antenna system is an important part of the same band antenna sharing solution. It can greatly reduce the cost and time of the 3G network construction. The SASU supports 900 MHz and 2100 MHz frequency bands. The SASA is also an important part of the same band antenna sharing solution. It will cause an insertion loss of 0.8 dB in the downlink, but it can integrate transmit carriers from two antennas into one antenna, without affecting GSM network performance.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 34 of 59

RAN10.0 3900 Series NodeB Product Description

4.12 OM Platforms
The 3900 series NodeBs support two OM platforms, namely the LMT and the M2000, with which the 3900 series NodeBs perform the following OM functions: Supporting local maintenance, remote maintenance, and reverse maintenance Supporting Bootstrap Protocol (BOOTP) and Dynamic Host Configuration Protocol (DHCP) when data is not configured or the NodeB is faulty, the NodeB automatically sets up an OM channel to enhance system reliability and to perform remote troubleshooting Supporting configuration baseline and simplifies the configuration rollback process to roll back configuration more reliably Providing the intelligent out-of-service function. Before the NodeB is out of service, the UE is handed over to another 2G or 3G cell when the NodeB gradually reduces the cell pilot power. Such a handover prevents service interruption Providing the topology scanning of RRU networking and automatically monitors the topology to free manual operations Providing the complete system self-testing function to support local software commissioning

4.13 Environment Adaptability


The 3900 series NodeBs provide a comprehensive solution applicable to different environments. The 3900 series NodeBs fulfill the following outdoor environmental conditions:

Waterproof and dustproof design of the RRU complies with the International Protection (IP) 65 standard. The RRU provides class-1 protection against damp, mould, and salt mist. The rack for RRUs can prevent them from exposure to solar radiation and adverse environments. The RRU works normally in the solar radiation of 1,120 W/m2 with the temperature ranging from 40 to +50 C C. The waterproof and dustproof design of the BTS3900A complies with the IP55 standard. The BTS3900A provides class-1 protection against damp, mould, and salt mist. The BTS3900A cabinet can resist solar radiation and adverse environments. The BTS3900A works normally in the solar radiation of 1,120 W/m2 with the temperature ranging from 40 to +45 C C. The waterproof and dustproof design of the BTS3900C complies with the IP55 standard. The BTS3900C provides class-1 protection against damp, mould, and salt mist. The BTS3900C works normally in the temperature ranging from 40 to +45 with the solar radiation of 1,120 W/m2 and the temperature C C ranging from 40 to +50 without solar radiation. C C

The 3900 series NodeBs fulfill the indoor environmental conditions when they comply with the IP20 standard. The BBU3900 works normally within the temperature ranging from 20 to +55 and the BTS3900 works normally C C within the temperature ranging from 20 to +50 C C. The 3900 series NodeBs also provide a comprehensive auxiliary product solution regarding the following aspects:

Power distribution

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 35 of 59

RAN10.0 3900 Series NodeB Product Description


Surge protection Transmission cables Transmission equipment installation Power backup

4.14 Capacity Expansion Evolution


Based on the Huawei IP switch platform, the 3900 series NodeBs support the GSM-WCDMA dual-mode cabinet. In addition, the 3900 series NodeBs are HSPA+ ready in hardware. This facilitates smooth evolution to the LTE. The BBU3900 is HSPA+ Phase 1 (downlink 64QAM and MIMO 2x2) ready in hardware. The BBU3900 supports HSPA+ Phase 2 (uplink 16QAM) by adding baseband processing boards. The BBU3900 supports the LTE by adding baseband processing boards. The RRU and WRFU are HSPA+ and LTE ready in hardware.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 36 of 59

RAN10.0 3900 Series NodeB Product Description

5
5.1 Overview

Operation and Maintenance

Based on the Man Machine Language (MML) and Graphic User Interface (GUI), the 3900 series NodeBs provide a universal OM mechanism irrelevant to hardware and take into consideration customers' requirements for equipment operation and maintenance. In one word, they offer highly customized and powerful OM functions. Figure 5-1 shows the OM systems of the 3900 series NodeBs. Figure 5-1 OM systems of the 3900 series NodeBs

M2000: Huawei Mobile Element Management System LMT: Local Maintenance Terminal NodeB: UMTS Base Transceiver Station RNC: Radio Network Controller

The LMT and M2000 are two OM systems that implement comprehensive maintenance for the 3900 series NodeBs. LMT One LMT is used to maintain one NodeB. The LMT supports the local maintenance by directly connecting to the NodeB or the remote maintenance by connecting to the NodeB through maintenance channels. The LMT performs the following functions:

Data configuration

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 37 of 59

RAN10.0 3900 Series NodeB Product Description


Status monitoring (through emulation panel) Alarm monitoring Software upgrade Testing and commissioning

The LMT also maintains the NodeB through MML and GUI. M2000 The M2000 is the network management center of the WCDMA Radio Access Network (WRAN), which remotely maintains the NodeB in batches. The M2000 performs the following functions:

Data configuration (CME-based) Alarm monitoring Performance monitoring Software upgrade

The M2000 also maintains the NodeB through MML and GUI. It can support different types of NodeB and different versions of software at the same time.

5.2 OM Functions
The 3900 series NodeBs provide a universal OM mechanism independent of hardware. The mechanism includes security management, equipment management, fault management, software management, and performance management.

5.2.1 Security Management


Security management is to manage the connection between NodeB software and Operation and Maintenance Center (OMC) (that is, the LMT or M2000 in the WRAN), user authentication, encryption, and forward resolution of interface messages.

5.2.2 Equipment Management


Equipment management provides data configuration and status management of all internal equipment (boards and modules) and external equipment (power supply, EMI, and RET) of the NodeB.

5.2.3 Fault Management


Fault management accomplishes functions such as fault detection, alarm reporting, alarm-related troubleshooting, fault isolation and self-healing.

5.2.4 Software Management


Software management provides software downloading and activation, patch upgrade, file uploading and downloading functions in addition to consistency check of software and hardware versions, version management, and software version upgrade. Software management is also a means to upgrade software locally through the USB port on the BBU3900 panel instead of through a PC.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 38 of 59

RAN10.0 3900 Series NodeB Product Description

5.2.5 Performance Management


Performance management includes subscription of NodeB performance counters, periodical control of performance statistics, and measurement, sampling, storage, and reporting of performance counters.

5.2.6 Commissioning Management


The 3900 series NodeBs perform commissioning functions in two ways, namely universal testability frame and specific testing/commissioning. The universal testability frame provides a universal testing mechanism to facilitate the future extended testing. It also provides a common test template regarding immediate test, periodical task test, and performance counter test, which facilitates the template-based extended testing in the future. The NodeB provides a variety of testing and commissioning functions for easy maintenance and fault diagnosis. The specific testing/commissioning has the following functions:

E1/T1 online BER test, RTWP test, and CPU usage test NodeB logs and one-push uploading of NodeB logs Interface tracing of Iub and internal interface Local serial port commissioning and serial port redirection

5.2.7 Environment Monitoring


The 3900 series NodeBs are attendance-free and widely applicable, which requires a sound environment monitoring system to ensure the normal running of the NodeB equipment and to handle all possible emergencies. The environment monitoring system provides customized solutions regarding door control, infrared, smoke, water immersion, humidity, and temperature. Users can also define external alarms.

5.2.8 License Management


The M2000 is responsible for applying for and activating WRAN licenses. It delivers license control items to a NodeB and through these items controls the current services and capacity of the NodeB. The function control items include HSDPA, OTSR, HSUPA, and MBMS, while the resource control items include the number of CEs, number of sectors and carriers, and power control. The 3900 series NodeBs also provide interfaces for querying license control items, clearing license, and setting license function switches.

5.2.9 Task Management


The 3900 series NodeBs provide maintenance for the BBU, RRU, RET, and EMI. The 3900 series NodeBs comply with the Antenna Line Device (ALD) protocol of AISG2.0 and 3GPP, and downwards compatible with the AISG1.1 protocol. The 3900 series NodeBs provide the RET antenna equipment with all OM functions, including auto scanning, data configuration (setting of the antenna tilt and TMA gain), status query, and fault reporting.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 39 of 59

RAN10.0 3900 Series NodeB Product Description

The 3900 series NodeBs support self-detection of complete hardware installation and adopts the software package stored in the USB disk of the NodeB to perform local upgrade, thus saving time for upgrade. In addition, it requires no local software commissioning.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 40 of 59

RAN10.0 3900 Series NodeB Product Description

6
6.1 Overview 6.2 System Reliability

Reliability

The 3900 series NodeBs introduce a fresh new NodeB system structure and provides a complete redundancy design. It also takes advantage of Huawei large-capacity ASIC chips to enhance the integrity of modules, reduce the number of parts, and greatly improve the reliability of the system.

The system reliability of the 3900 series NodeBs is embodied in the load-sharing and redundancy configuration design, which optimizes the fault detection/isolation technology of boards and systems and greatly improves the reliability of the system.

Redundancy Design
The main control board, transmission board, power supply unit, and fan in the NodeB all support redundancy. The BBU supports load sharing. The CPRI port that connects the BBU and the RRU supports ring networking. When one CPRI link is faulty, the NodeB can automatically switch to another CPRI link. The key data such as software version and data configuration files in the NodeB supports redundancy.

Reliability Design
The NodeB can automatically self-detect and diagnose hardware failures and environment problems, and then report alarms. It also attempts to conduct self-healing to clear faults. If the self-healing fails, it can automatically isolate the faults.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 41 of 59

RAN10.0 3900 Series NodeB Product Description

6.3 Hardware Reliability


Anti-Misinsertion Function of Boards
When a board is wrongly inserted into the slot of another board, the mistaken board cannot be connected to the backplane and in this way the equipment is free from damage.

Overtemperature Protection
When the ambient temperature of the power amplifier on the RRU is too high, the NodeB generates overtemperature alarms and immediately switches off the power amplifier to prevent it from damage.

Power Supply Reliability


Power supply units of the 3900 series NodeBs are also reliable in the following aspects: The 3900 series NodeBs have wide-range voltage and surge protection functions. The 3900 series NodeBs provide power failure protection for programs and data. The boards protect power supply against overvoltage, overcurrent, and reverse connection of positive and negative poles. Hierarchical shutdown The outdoor NodeB performs shutdown for the PA according to the backup power capacity.

Surge Protection Reliability


The 3900 series NodeBs take surge protection measures on AC/DC power sockets, input/output signal ports (E1 port, interconnection port, and Boolean alarm port), antenna connectors, and GPS ports.

6.4 Software Reliability


The software reliability includes the redundancy of key files and data, and the powerful error tolerance of software.

Software Redundancy
The 3900 series NodeBs provide redundancy for key files and data such as software versions and data configuration files to prevent them from damage and to ensure the normal running of the NodeBs. Redundancy of software versions The 3900 series NodeBs provide separate redundancy for software versions including the BootROM software version to avoid version problems. If one version is faulty, the NodeB can switch to the backup version. Redundancy of data configuration files

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 42 of 59

RAN10.0 3900 Series NodeB Product Description

The 3900 series NodeBs provide separate redundancy for data configuration files to avoid interrupting the running of the files. If the current file is faulty, the backup file can still work properly.

Error Tolerance
When the software is faulty, it does not affect the entire NodeB because the system is capable of self-healing. The software error tolerance functions are as follows: Scheduled detection of key resources The 3900 series NodeBs perform occupancy check on software resources. If resource hang-up occurs due to software faults, the NodeB can release the unavailable resources in time and export logs and alarms. Task monitoring During the running of software, the 3900 series NodeBs monitor the internal errors of all software and some hardware faults, if any. The 3900 series NodeBs also monitor task progress and running status, report alarms when the system is faulty, and try to restore the task by self-healing. Data consistency check The 3900 series NodeBs perform scheduled or event-triggered data consistency check and can restore the data consistency preferably or preferentially. Also, they generate related logs and alarms. Dongle The 3900 series NodeBs can detect the irregular running status of the software and then automatically reset the system through the dongles at both software and hardware levels.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

7
Table 7-1 Technical specifications of the BTS3900 Item
Band

Technical Specifications

7.1 Technical Specifications of the BTS3900


Specification
2100 MHz RX: 1920 MHz to 1980 MHz TX: 2110 MHz to 2170 MHz Capacity 24 cells Maximum configuration: 6 x 4, 3 x 8 UL: 1,536 CEs DL: 1,536 CEs Output power One WRFU supports four carriers. The output power at the antenna connector on the WRFU is 80 W.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output power is measured at the antenna connector of the base station. One-carrier configuration: 60 W per carrier Two-carrier configuration: 40 W per carrier (20 W per carrier in 1001 configuration) Three-carrier or four-carrier configuration: 20 W per carrier

Receiver sensitivity

Band

1-way receiver sensitivity (dBm)

2-way receiver sensitivity) (dBm) 128.6

Remarks

Band I (2100 MHz)

125.8

As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Receiver sensitivity

Specification
Band I (2100 MHz) 126.5 129.3 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001.

Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)

A maximum of 32 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm 900 mm x 600 mm x 450 mm

Empty cabinet: 70 3 x 1 configuration: 120 Full configuration: 160

Input power

48 V DC, value range: 38.4 V DC to 57 V DC +24 V DC, value range: +21.6 V DC to +29 V DC 220 V AC single-phase, value range: 176 V AC to 290 V AC 220 V AC three-phase, value range: 176/304 V AC to 290/500 V AC

Power consumption

Configuration 3x1 3x2 3x3 3x4

Each carrier 20 W 20 W 20 W 20 W

Typical power consumption 520 W 610 W 810 W 1020 W

Maximum power consumption 620 W 830 W 1070 W 1330 W

The typical power consumption is reached when the output power per carrier on the cabinet top is 20 W and the BTS3900 works with a 50% load. The maximum power consumption is reached when the output power per carrier on the cabinet top is 20 W and the BTS3900 works with a 100% load.

Temperature Relative humidity Absolute humidity Air pressure Protection

20C to +50 C 5% RH to 95% RH (125) g/m3 70 kPa to 106 kPa IP20

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
degree Storage Transportation Anti-seismic performance

Specification

ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)

EMC

The NodeB meets the EMC requirements and complies with the following standards:

CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.

7.2 Technical Specifications of the BTS3900A


Table 7-2 Technical specifications of the BTS3900A Item
Band

Specification
2100 MHz RX: 1920 MHz to 1980 MHz TX: 2110 MHz to 2170 MHz

Capacity

24 cells Maximum configuration: 6 x 4, 3 x 8 UL: 1,536 CEs DL: 1,536 CEs

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Output power

Specification
One RF module supports four carriers. The output power at the antenna connector of the WRFU is 80 W.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output power is measured at the antenna connector of the base station. One-carrier configuration: 60 W per carrier Two-carrier configuration: 40 W per carrier (20 W per carrier in 1001 configuration) Three-carrier or four-carrier configuration: 20 W per carrier

Receiver sensitivity

Band

1-way receiver sensitivity (dBm)

2-way receiver sensitivity (dBm) 128.6

Remarks

Band I (2100 MHz)

125.8

As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001.

126.5

129.3

Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)

A maximum of 32 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm RF cabinet: 700 mm x 600 mm x 480 mm APM30 cabinet: 700 mm x 600 mm x 480 mm RF cabinet: 55 APM30 cabinet: 65 WRFU: 12 3x1 configuration: 165 (without batteries) Full configuration: 210 (RF cabinet with 6 WRFUs and without batteries) 165 (RF cabinet with 3 WRFUs and without batteries)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Input power

Specification
220 V AC single-phase: 176 V AC to 290 V AC 220V AC three-phase: 176/304 V AC to 290/500 V AC 110 V AC dual-live-wire 48 V DC, voltage range: 38.4 V DC to 57 V DC

Power consumption

Power consumption

Power backup duration in typical power estimated on the basis of the battery capacity Typical power consumption (with 50% load) 630 W 730 W 950 W 1220 W Maximum power consumption (with 100% load) 740 W 970 W 1300 W 1580 W 50 Ah 100 Ah

Configuration

3x1 3x2 3x3 3x4 Built-in battery Temperature

3.8 hours 3.2 hours 2.3 hours 1.6 hours

8.8 hours 7.5 hours 5.2 hours 3.8 hours

50 Ah or 100 Ah (optional) 40C to +45 (with 1120 W/m solar radiation and APM heat exchanger) C 40C to +50 (with 1120 W/m solar radiation and APM air filter) C
2 2

Relative humidity Absolute humidity Air pressure Protection degree Storage Transportation Anti-seismic performance

5% RH to 100% RH (130) g/m


3

70 kPa to 106 kPa IP55 ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing - Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
EMC

Specification
The NodeB meets the EMC requirements and complies with the following standards:

CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.

7.3 Technical Specifications of the DBS3900


Both RRU3801C and RRU3804 can work as the RF module of the DBS3900. Table 7-3 and Table 7-4 list the technical specifications of the DBS3900 configured with different RF modules. Table 7-3 Technical specifications of the DBS3900 (BBU3900 + RRU3801C) Item
Band

Specification
Band Band I (2100 MHz) Band II (1900 MHz) Band III /IX (1800 MHz) Band IV (AWS) Band V/VI (850 MHz) Band VIII (900 MHz) 17101755 824849 880915 21102155 869894 925960 RX band (MHz) 19201980 18501910 17101785 TX band (MHz) 21102170 19301990 18051880

Capacity

12 cells Maximum configuration: 6 x 2, 3 x 4 UL: 1,536 CEs DL: 1,536 CEs

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Output power Receiver sensitivity

Specification
One RRU3801C supports two carriers with 40 W output power. Band 1-way receiver sensitivity (dBm) Band I (2100 MHz) 125.8 128.6 As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. 2-way receiver sensitivity (dBm) Remarks

126.5

129.3

Other bands

125.6

128.4

126.3

129.1

Optical/ electrical Clock synchronization Specifications (height x width x depth)

A maximum of 48 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock on the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm BBU3900: 86 mm x 442 mm x 310 mm RRU3801C: 480 mm x 365 mm x 145 mm (without rack and housing) 610 mm x 380 mm x 200 mm (with rack and housing)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Weight (kg)

Specification
BBU3900: in full configuration: 11; in 3 x 2 configuration: 7 RRU3801C: 20

Input power

RRU3801C: 48 V DC, voltage range: 40 V DC to 60 V DC 220 V AC, voltage range: 150 V AC to 300 V AC BBU3900: +24 V DC, voltage range: +21.6 V DC to +29 V DC 48 V DC, voltage range: 38.4 V DC to 57 V DC

Power consumption

Power consumption

Power backup duration in typical power estimated on the basis of the battery capacity Maximum power consumption (W) (100% load) 24 Ah 50 Ah 100 Ah

Configuration

Typical power consumption (50% load)

3x1 3x2 Temperature

540 W 680 W

620 W 830 W

1.4 hours 1.1 hours

3.6 hours 2.9 hours

8.4 hours 6.7 hours

BBU3900: 20C to +55 C RRU3801C: 40C to +50 (with 1120 W/m2 solar radiation) C 40C to +55 (without solar radiation) C

Relative humidity

BBU3900: 5% RH to 85% RH RRU3801C: 5% RH to 100% RH


3 3

Absolute humidity Air pressure Protection degree Storage Transportation Anti-seismic performance

BBU3900: (125) g/m

RRU3801C: (130) g/m 70 kPa to 106 kPa BBU3900: IP20 RRU3801C: IP65

ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
EMC

Specification
The NodeB meets the EMC requirements and complies with the following standards:

CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.

Table 7-4 Technical specifications of the DBS3900 (BBU3900 + RRU3804) Item


Band

Specification
Band Band I (2100 MHz) Band II (1900 MHz) Band V /VI (850 MHz) Band IV (AWS) 17101755 21102155 824849 869894 18501910 19301990 RX band (MHz) 19201980 TX band (MHz) 21102170

Capacity

24 cells Maximum configuration: 6 x 4, 3 x 8 UL: 1536 CEs DL: 1536 CEs

Output power

A single RRU3804 supports up to four carriers with a 60 W output power at the antenna connector with four carriers.

One-carrier configuration: 50 W per carrier Two-carrier configuration: 30 W per carrier (20 W per carrier in 1001 configuration) Three-carrier configuration: 20 W per carrier Four-carrier configuration: 15 W per carrier1

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Receiver sensitivity

Specification
Band 1-way receiver sensitivity (dBm) Band I (2100 MHz) 125.8 2-way receiver sensitivity (dBm) 128.6 As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. Remarks

126.5

129.3

Band II (1900 MHz) Band V/VI (850 MHz)

125.3

128.1

126.0

128.8

Receiver sensitivity

Other bands

125.6

128.4

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item

Specification
126.3 129.1 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001.

Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)

A maximum of 48 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, and IP clock Precision: 0.05 ppm BBU3900: 86 mm x 442 mm x 310 mm RRU3804: 480 mm x 270 mm x 140 mm (without the housing and connectors) 485 mm x 285 mm x 170 mm (with the housing and connectors) BBU3900: full configuration: 11 typical configuration (1 PSU, 1 WBBP, 1 WMPT): 7 RRU3804: 15 (without the housing) 17 (without the housing)

Input voltage

RRU3804: 48 V DC, voltage range: 36 V DC to 57 V DC BBU3900: +24 V DC, voltage range: +21.6 V DC to +29 V DC 48 V DC, voltage range: 38.4 V DC to 57 V DC Power consumption Power backup duration in typical power estimated on the basis of the battery capacity Maximum power consumption (100% load) 500 W 740 W 970 W 24 Ah 50 Ah 100 Ah

Power consumption

Configuration

Typical power consumption (50% load) 400 W 550 W 710 W

3x1 3x2 Power consumption Temperature 3x3

2.2 hours 1.5 hours 1.0 hours

5.5 hours 3.7 hours 2.8 hours

12.0 hours 8.5 hours 6.4 hours

BBU3900: 20C to +55 C RRU3804: 40C to +50 (with 1120 W/m2 solar radiation) C 40C to +55 (without solar radiation) C

Relative humidity

BBU3900: 5% RH to 95% RH RRU3804: 5% RH to 100% RH

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Absolute humidity

Specification
BBU3900: (125) g/m
3 3

RRU3804: (130) g/m Air pressure Protection degree 70 kPa to 106 kPa BBU3900: IP20 RRU3804: IP65 Storage Transportation Anti-seismic performance

ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations". ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)

EMC

The NodeB meets the EMC requirements and complies with the following standards:

CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.

7.4 Technical specifications of the BTS3900C


Table 7-5 Technical specifications of the BTS3900C Item
Band

Specification
Band Band I (2100 MHz) Band II (1900 MHz) RX band (MHz) 19201980 18501910 TX band (MHz) 21102170 19301990

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item

Specification
Band V/VI (850 MHz) Band IV (AWS) 824849 17101755 869894 21102155

Capacity

3 cells Maximum configuration: 1 x 3 UL: 384 CEs DL: 384 CEs

Output power

The RRU3801C supports two carriers with a 40 W output power at the antenna connector. The RRU3804 supports four carriers with a 60 W output power at the antenna connector.
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power is measured at the antenna connector of the base station. The output power of the RRU3804 in different configurations is as follows: One-carrier configuration: 50 W per carrier Two-carrier configuration: 30 W per carrier (20 W per carrier in 1001 configuration) Three-carrier configuration: 20 W per carrier Four-carrier configuration: 15 W per carrier

Receiver sensitivity

Band

1-way receiver sensitivity (dBm)

2-way receiver sensitivity (dBm) 128.6

Remarks

Band I (2100 MHz)

125.8

As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001.

Receiver sensitivity

Band I (2100 MHz)

126.5

129.3

Other bands

125.6

128.4

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item

Specification
126.3 129.1 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001.

Optical/ electrical Clock synchronization Specifications (height x width x depth) Weight (kg)

A maximum of 8 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, and IP clock Precision: 0.05 ppm 600 mm x 400 mm x 390 mm 600 mm x 240 mm x 390 mm (when used as an outdoor BBU)

38 (configured with RRU3804) 35 (configured with RRU3801C)

Input voltage

48 V DC, voltage range: 38.4 V DC to 57 V DC 220 V AC single-phase, voltage range: 176V AC to 290V AC 110 V AC dual-live-wire, voltage range: 176/304 V AC to 290/500 V AC

Power consumption

With RRU3801C Configuration 3x1 With RRU3804 Configuration 3x1 Typical power consumption 300 W 360 W
2

Typical power consumption 360 W

Maximum power consumption 410 W

Maximum power consumption 380 W 450 W

Power consumption Temperature

3x2

-40 to +45C (with 1120 W/m solar radiation) C -40 to +50C (without solar radiation) C

Relative humidity Absolute humidity Air pressure Protection degree Storage Transportation

5% RH to 100% RH (130) g/m


3

70 kPa to 106 kPa IP55 ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations". ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Item
Anti-seismic performance

Specification
IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)

EMC

The NodeB meets the EMC requirements and complies with the following standards:

CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

8
APM ATM BBU BER CPRI DAGC FE HSDPA HSUPA IP LTE PDU PMU PSU RNC WRRU TCO UEIU UELP UFAN UFLP UPEU

Acronyms and Abbreviations


Full Spelling
Advanced Power Module Asynchronous Transfer Mode; Baseband Unit Bit Error Rate Common Public Radio Interface Digital Automatic Gain Control Fast Ethernet High Speed Downlink Packet Access High Speed Uplink Packet Access Internet Protocol Long Term Evolution Power Distribution Unit Power Monitoring Unit Power Supply Unit Radio Network Controller Radio Remote Unit for WCDMA Total Cost of Ownership Universal Environment Interface Unit Universal E1/T1 Lightning Protection unit Universal Fan module Universal FE Lightning Protection unit Universal Power and Environment interface Unit

Acronym and Abbreviation

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

RAN10.0 3900 Series NodeB Product Description

Acronym and Abbreviation


USCU UTRP WBBP WMPT WRFU

Full Spelling
Universal Satellite card and Clock Unit Universal Transmission Processing unit WCDMA BaseBand Process unit WCDMA Main Processing&Transmission unit WCDMA Radio Filter Unit

03 (2008-09-18)

COMMERCIAL IN CONFIDENCE

Page 43 of 59

S-ar putea să vă placă și