Product Description
Issue Date
03 2008-09-18
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Contents
1 Introduction .....................................................................................................................6
1.1 3900 Series NodeBs ........................................................................................................................ 6 1.2 Product Features.............................................................................................................................. 7
4 Features.........................................................................................................................31
4.1 Advanced Platform Structure.......................................................................................................... 31 4.2 High Integrity and Large Capacity.................................................................................................. 31
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 4 of 59
RAN10.0 3900 Series NodeB Product Description 4.3 High Performance .......................................................................................................................... 31 4.4 ATM/IP Dual Stack.......................................................................................................................... 32 4.4.1 ATM........................................................................................................................................ 32 4.4.2 IP ........................................................................................................................................... 32 4.5 Multiple Clock and Synchronization Modes ................................................................................... 33 4.6 HSDPA Services............................................................................................................................. 33 4.7 HSUPA Services............................................................................................................................. 33 4.8 MBMS............................................................................................................................................. 33 4.9 High-Velocity UE Access................................................................................................................ 34 4.10 Antenna Enhancement Technology.............................................................................................. 34 4.11 Same Band Antenna Sharing ....................................................................................................... 34 4.12 OM Platforms ............................................................................................................................... 35 4.13 Environment Adaptability.............................................................................................................. 35 4.14 Capacity Expansion Evolution...................................................................................................... 36
6 Reliability.......................................................................................................................41
6.1 Overview ........................................................................................................................................ 41 6.2 System Reliability ........................................................................................................................... 41 6.3 Hardware Reliability ....................................................................................................................... 42 6.4 Software Reliability......................................................................................................................... 42
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 5 of 59
1
1.1 3900 Series NodeBs
Introduction
The mobile communications, which takes an ever-changing presence with each passing day, blazes a trail for the upgrade of technologies and products. The growing trend of mobile communications comprises a series of evolution, from GSM to EDGE to EDGE+ and from WCDMA to HSPA to HSPA+ and LTE, and it is worth mentioning that WiMAX also joins the 3G family. To follow the trend, the network operators have to devote more CAPEX and OPEX to the dramatic change of technologies, and therefore they are currently focusing on the merge of multiple network systems into a more cost-effective one. Upon the transition of mobile networks, the network operators target at the Blue Ocean Strategy and invite innovative and responsive partners. Customer-oriented and innovative, Huawei advocates four basic technological concepts: green, merge, wideband, and evolution. Huawei will take the lead in developing the next-generation base stations and the 3900 series NodeBs, Huawei's fourth generation base stations, will outclass other base stations to benefit operators with future-oriented networks. Huawei unveils cutting-edge techniques in the 3900 series NodeBs, such as wideband, multi-mode system, and modular design. The 3900 series NodeBs consist of only three basic functional modules, characterized by compact structure, high integration, low power consumption, and easy and quick deployment. Flexible combinations of functional modules and auxiliary devices encourage Huawei to diversify the products. More importantly, the modules for different modes of systems can be installed in one cabinet to work as a base station adapting to different scenarios. Huawei also actively introduces new frequency bands and technologies to well meet operators' requirement for a compact multi-mode mobile network system. Figure 1-1 shows the basic functional modules and auxiliary devices of the 3900 series NodeBs.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 6 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 7 of 59
The 3900 series NodeBs use the high-efficiency digital Power Amplifier (PA), which greatly reduces power consumption and helps build a green communication network. Compared with the traditional NodeB, the macro NodeB (BTS3900) has its power consumption reduced by 30%; compared with the traditional macro NodeB, the BTS3900A cabinet, which is in direct-ventilation, has its power consumption reduced by 40%. Based on the IP switch and multi-carrier technologies, the 3900 series NodeBs support the bandwidth of over 100 Mbit/s, which keeps up with the fast growing mobile data services and provides users with higher data transmission rate. Smooth evolution to future radio network systems The 3900 series NodeBs support smooth evolution to HSPA+ and Long Term Evolution (LTE), thus fully protecting the investment of network operators.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 8 of 59
2
2.1 Product Overview
APM30 power cabinet Indoor macro cabinet Outdoor cabinet Outdoor mini cabinet
System Architecture
The 3900 series NodeBs feature a modular design. The basic functional modules are the baseband unit (BBU3900) and the indoor RF unit (WRFU), and outdoor remote RF unit (RRU). The BBU is connected to the RRU or WRFU through CPRI ports and optical cables. The auxiliary devices for the BTS3900 are as follows:
The variable combinations of functional modules and auxiliary devices provide flexible site solutions for different scenarios.
2.2 BBU3900
2.2.1 Physical Structure of the BBU3900
The BBU3900 is a compact case structure that requires a 19-inch-wide and 2-U-high space. It can be installed on a wall, on the staircase, in the storeroom, or in an outdoor cabinet on the existing network. It can be also installed in an outdoor cabinet of the existing network. Figure 2-1 shows the physical structure of the BBU3900. Figure 2-1 Physical structure of the BBU3900
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 9 of 59
Port
E1 port FE electrical port FE optical port USB port for loading USB port for test Serial port for commissioning GPS port
Quantity
1 1 1 1 1 1 1 3 1 1 1
Connector Type
DB26 connector RJ45 connector SFP connector USB connector USB connector RJ45 connector SMA connector SFP connector 3V3 connector RJ45 connector RJ45 connector
Remarks
One port supporting four E1s Software loading Test port NodeB local maintenance 48 V DC power input and +24 V DC power input Providing two RS485 monitoring ports; connecting to the external monitoring device
WBBP UPEU
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 10 of 59
Board
UPEU
Port
EXT-ALM0 EXT-ALM1
Quantity
1 1
Connector Type
RJ45 connector RJ45 connector
Remarks
Providing eight dry contact alarm inputs; connecting to the external alarm device
Table 2-2 Ports on the optional hardware units of the BBU3900 Board
UELP
Port
INSIDE OUTSIDE
Quantity
1 1 2 2
Connector Type
DB25 connector DB26 connector RJ45 connector RJ45 connector
Remarks
Port for four E1/T1 signal inputs Port for four E1/T1 signal outputs Connecting to the NodeB Connecting to the external device. The FE0 (OUTSIDE) connects to the FE0 (INSIDE) and the FE1 (OUTSIDE) connects to the FE1 (INSIDE). Connecting to the RGPS signal cable Connecting to the BITS clock Port for testing clock signal output RF signal input port of the satellite card Providing eight ATM over E1s/T1s or eight IP over E1s/T1s Connecting to external monitoring devices
UFLP
USCU
RGPS port BITS port Clock test port Antenna port for the satellite card
3 1 1 1 2 1 1 1 1
DB8 connector SMA connector SMA connector SMA connector DB26 connector RJ45 connector RJ45 connector RJ45 connector RJ45 connector
UTRP UEIU
The UEIU is a monitoring and dry contact extension board for the UPEU.
2.3 RRU
2.3.1 Specifications of the RRU
The RRU is the outdoor RF remote unit that can be installed close to the antenna. The RRU is classified into RRU3804 and RRU3801C based on different output power and
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 11 of 59
processing capabilities. Table 2-3 describes the specifications of the RRU3804 and the RRU3801C. Table 2-3 Specifications of the RRU3801C and the RRU3804 RRU Type Maximum Output Power Number of Carriers Supported
RRU3801C 40 W 2 RRU3804 40 W 4
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 12 of 59
Connector Type
9-pin, round, and waterproof connector ESFP socket DB15 connector (shared by the fan) DIN, round, and waterproof connector DIN, round, and waterproof connector 2W2 connector
Quantity
1
Remarks
Ports for 48 V DC or 220 V AC power input Transmission ports Alarm port Other ports
Optical ports Port for 4-channel dry contact alarms Main TX/RX port
2 1 1
RX diversity port
Port for interconnection between combined modules Port for the RET antenna Commissioning port
1 1
Connector Type
OT terminal ESFP socket DB15 connector (shared by the fan) DIN, round, and waterproof connector
Quantity
1 2 1
Remarks
Port for 48 V DC power input Transmission ports Alarm port
Other ports 1
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 13 of 59
Port
RX diversity port
Connector Type
DIN, round, and waterproof connector 2W2 connector
Quantity
1
Remarks
2.4 WRFU
2.4.1 Specifications of the WRFU
The WRFU is categorized into 40 W WRFU and 80 W WRFU based on different output power and processing capabilities. The 40 W WRFU and 80 W WRFU have the same physical structure, dimensions, weight, and physical ports. Table 2-6 Specifications of the WRFU WRFU Type Maximum Output Power Number of Carriers Supported
80 W WRFU 80 W 4 40 W WRFU 40 W 2
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 14 of 59
Connector Type
3V3 connector N female connector SFP female connector QMA female connector RJ45 connector
Quantity
1 2 2 2 1
Remarks
Port for 48 V DC input power
Port for connecting the antenna system Ports for connecting the BBU Ports for cascading WRFUs Commissioning port
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 15 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 16 of 59
APM30 Specification
600 mm 700 mm 480 mm
APM100 Specification
600 mm x 1130 mm x 600 mm
< 65 kg
88 kg
-40C to +45C (with 1120 W/m2 solar radiation) 40C to +50C (without solar radiation) When the ambient temperature is lower than 20 an AC heater is C, required.
AC input
Input voltage
Rated voltage: 200 V AC to 240 V AC Permissible voltage range: 176 V AC to 290 V AC Rated voltage: 100/200 V AC to 120/240 V AC
Permissible voltage range: 90/180 V AC to 135/270
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 17 of 59
Item
48 V 100 Ah built-in batteries
APM30 Specification
APM100 Specification
When two cabinets are installed in stack mode, the upper cabinet should be a -48 V DC cabinet, and the lower cabinet can be either a +24 V DC cabinet or a 220 V AC cabinet, depending on power configuration.
The cabinet structure varies with the power input. Figure 2-6 shows the single indoor cabinet with 48 V DC power. Figure 2-7 shows the single indoor cabinet with +24 V DC power. Figure 2-8 shows the single indoor cabinet with 220 V AC power. Figure 2-9 shows two cabinets in stack mode. Figure 2-6 Single indoor cabinet (48 V)
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 18 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 19 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 20 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 21 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 22 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 23 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 24 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 25 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 26 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 27 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 28 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 29 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 30 of 59
4
4.1 Advanced Platform Structure
Features
The advanced platform structure of the 3900 series NodeBs is described as follows: The 3900 series NodeBs that adopt the IP switch-based Huawei platform support the GU co-cabinet application, HSPA+, and smooth evolution to LTE. The 3900 series NodeBs introduce the module-sharing concept, that is, the distributed NodeB, cabinet macro NodeB, and compact mini NodeB share all baseband and RF modules. The three types of basic modules form different NodeB products that apply to different scenarios, thus lowering CAPEX and OPEX. The dual-star GE IP switch technology enables exchange of large amount of internal data and satisfies more data traffic needs for HSPA+ and LTE in the future. The hot-swappable BBU3900 provides eight slots for boards and supports smooth capacity expansion and evolution. The combination of the duplexer and Transceiver Unit (TRU) in the RF module enhances the integrity of RF parts and meets the future requirements of the minimized, high-efficiency, and low-cost NodeBs. A minimized NodeB cabinet is easy to carry and install, and the stacked NodeB cabinets take up a small footprint.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 31 of 59
The 3900 series NodeBs feature high receiver sensitivity. The 2-way receiver sensitivity is higher than 129.3 dBm without the Tower Amplification (TMA). The WRFU supports 80 W output power and the RRU3804 supports 60 W output power, which means that the PAs of the 3900 series NodeBs increase to 40%. The 3900 series NodeBs support open-loop TX diversity and closed-loop TX diversity to enhance downlink coverage and capacity. A single RRU3804 (with an SRXU) supports 4-way RX diversity to enhance antenna receiver sensitivity.
4.4.2 IP
The IP transmission, based on IPs, supports the transmission of various data services on low-rate links. In this mode, the IP transmission resources are fully utilized and operators' investment is greatly reduced. In IP transmission, the 3900 series NodeBs support the following technologies: Native IP transmission that requires no additional hardware. Compared with the PWE3 technology, Native IP is more efficient, cost-effective, and independent of PWE3 external devices. IP over E1, to fully utilize the E1 resources of the existing network and to offer a complete solution of IP transmission Fractional Point-to-Point Protocol (PPP) ATM and IP dual stack, to protect operators' early investment in ATM transmission Compression and multiplexing technology, namely the multiplexing of PPP header compression, PPPMUX, and IPHC, to raise the transmission rate over E1 ports. With the technology of IPHC + PPP compression + PPPMUX, the E1 transmission rate of the 12.2 kbit/s voice service rises by up to 37%. FP Multiplex (MUX), to reduce the number of Medium Access Control (MAC) headers by multiplexing packets and to raise the transmission rate over FE ports. With this technology, the FE transmission rate of the 12.2 kbit/s voice service rises by up to 40%. Hybrid transmission, which enables services to meet different QoS requirements and then to allocate different transmission paths. For example, hybrid transmission enables real-time services to travel on electrical ports, such as E1/T1 ports, and non-real-time services to travel on Ethernet ports.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 32 of 59
4.8 MBMS
The 3900 series NodeBs support the Multimedia Broadcast and Multicast Service (MBMS) in the following aspects:
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 33 of 59
The 3900 series NodeBs support the setup, reconfiguration, and deletion of the MBMS notification Indicator Channel (MICH), and handle related signaling configuration. Each cell supports 16 Secondary Common Control Physical Channels (SCCPCHs). Each SCCPCH supports 4 Forward Access Channels (FACHs). Each cell supports 63 MBMS channels.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 34 of 59
4.12 OM Platforms
The 3900 series NodeBs support two OM platforms, namely the LMT and the M2000, with which the 3900 series NodeBs perform the following OM functions: Supporting local maintenance, remote maintenance, and reverse maintenance Supporting Bootstrap Protocol (BOOTP) and Dynamic Host Configuration Protocol (DHCP) when data is not configured or the NodeB is faulty, the NodeB automatically sets up an OM channel to enhance system reliability and to perform remote troubleshooting Supporting configuration baseline and simplifies the configuration rollback process to roll back configuration more reliably Providing the intelligent out-of-service function. Before the NodeB is out of service, the UE is handed over to another 2G or 3G cell when the NodeB gradually reduces the cell pilot power. Such a handover prevents service interruption Providing the topology scanning of RRU networking and automatically monitors the topology to free manual operations Providing the complete system self-testing function to support local software commissioning
Waterproof and dustproof design of the RRU complies with the International Protection (IP) 65 standard. The RRU provides class-1 protection against damp, mould, and salt mist. The rack for RRUs can prevent them from exposure to solar radiation and adverse environments. The RRU works normally in the solar radiation of 1,120 W/m2 with the temperature ranging from 40 to +50 C C. The waterproof and dustproof design of the BTS3900A complies with the IP55 standard. The BTS3900A provides class-1 protection against damp, mould, and salt mist. The BTS3900A cabinet can resist solar radiation and adverse environments. The BTS3900A works normally in the solar radiation of 1,120 W/m2 with the temperature ranging from 40 to +45 C C. The waterproof and dustproof design of the BTS3900C complies with the IP55 standard. The BTS3900C provides class-1 protection against damp, mould, and salt mist. The BTS3900C works normally in the temperature ranging from 40 to +45 with the solar radiation of 1,120 W/m2 and the temperature C C ranging from 40 to +50 without solar radiation. C C
The 3900 series NodeBs fulfill the indoor environmental conditions when they comply with the IP20 standard. The BBU3900 works normally within the temperature ranging from 20 to +55 and the BTS3900 works normally C C within the temperature ranging from 20 to +50 C C. The 3900 series NodeBs also provide a comprehensive auxiliary product solution regarding the following aspects:
Power distribution
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 35 of 59
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 36 of 59
5
5.1 Overview
Based on the Man Machine Language (MML) and Graphic User Interface (GUI), the 3900 series NodeBs provide a universal OM mechanism irrelevant to hardware and take into consideration customers' requirements for equipment operation and maintenance. In one word, they offer highly customized and powerful OM functions. Figure 5-1 shows the OM systems of the 3900 series NodeBs. Figure 5-1 OM systems of the 3900 series NodeBs
M2000: Huawei Mobile Element Management System LMT: Local Maintenance Terminal NodeB: UMTS Base Transceiver Station RNC: Radio Network Controller
The LMT and M2000 are two OM systems that implement comprehensive maintenance for the 3900 series NodeBs. LMT One LMT is used to maintain one NodeB. The LMT supports the local maintenance by directly connecting to the NodeB or the remote maintenance by connecting to the NodeB through maintenance channels. The LMT performs the following functions:
Data configuration
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 37 of 59
Status monitoring (through emulation panel) Alarm monitoring Software upgrade Testing and commissioning
The LMT also maintains the NodeB through MML and GUI. M2000 The M2000 is the network management center of the WCDMA Radio Access Network (WRAN), which remotely maintains the NodeB in batches. The M2000 performs the following functions:
The M2000 also maintains the NodeB through MML and GUI. It can support different types of NodeB and different versions of software at the same time.
5.2 OM Functions
The 3900 series NodeBs provide a universal OM mechanism independent of hardware. The mechanism includes security management, equipment management, fault management, software management, and performance management.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 38 of 59
E1/T1 online BER test, RTWP test, and CPU usage test NodeB logs and one-push uploading of NodeB logs Interface tracing of Iub and internal interface Local serial port commissioning and serial port redirection
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 39 of 59
The 3900 series NodeBs support self-detection of complete hardware installation and adopts the software package stored in the USB disk of the NodeB to perform local upgrade, thus saving time for upgrade. In addition, it requires no local software commissioning.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 40 of 59
6
6.1 Overview 6.2 System Reliability
Reliability
The 3900 series NodeBs introduce a fresh new NodeB system structure and provides a complete redundancy design. It also takes advantage of Huawei large-capacity ASIC chips to enhance the integrity of modules, reduce the number of parts, and greatly improve the reliability of the system.
The system reliability of the 3900 series NodeBs is embodied in the load-sharing and redundancy configuration design, which optimizes the fault detection/isolation technology of boards and systems and greatly improves the reliability of the system.
Redundancy Design
The main control board, transmission board, power supply unit, and fan in the NodeB all support redundancy. The BBU supports load sharing. The CPRI port that connects the BBU and the RRU supports ring networking. When one CPRI link is faulty, the NodeB can automatically switch to another CPRI link. The key data such as software version and data configuration files in the NodeB supports redundancy.
Reliability Design
The NodeB can automatically self-detect and diagnose hardware failures and environment problems, and then report alarms. It also attempts to conduct self-healing to clear faults. If the self-healing fails, it can automatically isolate the faults.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 41 of 59
Overtemperature Protection
When the ambient temperature of the power amplifier on the RRU is too high, the NodeB generates overtemperature alarms and immediately switches off the power amplifier to prevent it from damage.
Software Redundancy
The 3900 series NodeBs provide redundancy for key files and data such as software versions and data configuration files to prevent them from damage and to ensure the normal running of the NodeBs. Redundancy of software versions The 3900 series NodeBs provide separate redundancy for software versions including the BootROM software version to avoid version problems. If one version is faulty, the NodeB can switch to the backup version. Redundancy of data configuration files
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 42 of 59
The 3900 series NodeBs provide separate redundancy for data configuration files to avoid interrupting the running of the files. If the current file is faulty, the backup file can still work properly.
Error Tolerance
When the software is faulty, it does not affect the entire NodeB because the system is capable of self-healing. The software error tolerance functions are as follows: Scheduled detection of key resources The 3900 series NodeBs perform occupancy check on software resources. If resource hang-up occurs due to software faults, the NodeB can release the unavailable resources in time and export logs and alarms. Task monitoring During the running of software, the 3900 series NodeBs monitor the internal errors of all software and some hardware faults, if any. The 3900 series NodeBs also monitor task progress and running status, report alarms when the system is faulty, and try to restore the task by self-healing. Data consistency check The 3900 series NodeBs perform scheduled or event-triggered data consistency check and can restore the data consistency preferably or preferentially. Also, they generate related logs and alarms. Dongle The 3900 series NodeBs can detect the irregular running status of the software and then automatically reset the system through the dongles at both software and hardware levels.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
7
Table 7-1 Technical specifications of the BTS3900 Item
Band
Technical Specifications
Receiver sensitivity
Band
Remarks
125.8
As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Receiver sensitivity
Specification
Band I (2100 MHz) 126.5 129.3 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001.
Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)
A maximum of 32 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm 900 mm x 600 mm x 450 mm
Input power
48 V DC, value range: 38.4 V DC to 57 V DC +24 V DC, value range: +21.6 V DC to +29 V DC 220 V AC single-phase, value range: 176 V AC to 290 V AC 220 V AC three-phase, value range: 176/304 V AC to 290/500 V AC
Power consumption
Each carrier 20 W 20 W 20 W 20 W
The typical power consumption is reached when the output power per carrier on the cabinet top is 20 W and the BTS3900 works with a 50% load. The maximum power consumption is reached when the output power per carrier on the cabinet top is 20 W and the BTS3900 works with a 100% load.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
degree Storage Transportation Anti-seismic performance
Specification
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)
EMC
The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.
Specification
2100 MHz RX: 1920 MHz to 1980 MHz TX: 2110 MHz to 2170 MHz
Capacity
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Output power
Specification
One RF module supports four carriers. The output power at the antenna connector of the WRFU is 80 W.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output power is measured at the antenna connector of the base station. One-carrier configuration: 60 W per carrier Two-carrier configuration: 40 W per carrier (20 W per carrier in 1001 configuration) Three-carrier or four-carrier configuration: 20 W per carrier
Receiver sensitivity
Band
Remarks
125.8
As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001.
126.5
129.3
Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)
A maximum of 32 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm RF cabinet: 700 mm x 600 mm x 480 mm APM30 cabinet: 700 mm x 600 mm x 480 mm RF cabinet: 55 APM30 cabinet: 65 WRFU: 12 3x1 configuration: 165 (without batteries) Full configuration: 210 (RF cabinet with 6 WRFUs and without batteries) 165 (RF cabinet with 3 WRFUs and without batteries)
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Input power
Specification
220 V AC single-phase: 176 V AC to 290 V AC 220V AC three-phase: 176/304 V AC to 290/500 V AC 110 V AC dual-live-wire 48 V DC, voltage range: 38.4 V DC to 57 V DC
Power consumption
Power consumption
Power backup duration in typical power estimated on the basis of the battery capacity Typical power consumption (with 50% load) 630 W 730 W 950 W 1220 W Maximum power consumption (with 100% load) 740 W 970 W 1300 W 1580 W 50 Ah 100 Ah
Configuration
50 Ah or 100 Ah (optional) 40C to +45 (with 1120 W/m solar radiation and APM heat exchanger) C 40C to +50 (with 1120 W/m solar radiation and APM air filter) C
2 2
Relative humidity Absolute humidity Air pressure Protection degree Storage Transportation Anti-seismic performance
70 kPa to 106 kPa IP55 ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing - Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
EMC
Specification
The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.
Specification
Band Band I (2100 MHz) Band II (1900 MHz) Band III /IX (1800 MHz) Band IV (AWS) Band V/VI (850 MHz) Band VIII (900 MHz) 17101755 824849 880915 21102155 869894 925960 RX band (MHz) 19201980 18501910 17101785 TX band (MHz) 21102170 19301990 18051880
Capacity
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Output power Receiver sensitivity
Specification
One RRU3801C supports two carriers with 40 W output power. Band 1-way receiver sensitivity (dBm) Band I (2100 MHz) 125.8 128.6 As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. 2-way receiver sensitivity (dBm) Remarks
126.5
129.3
Other bands
125.6
128.4
126.3
129.1
A maximum of 48 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock on the Iub interface, GPS clock, OCXO free-run clock, and IP clock Precision: 0.05 ppm BBU3900: 86 mm x 442 mm x 310 mm RRU3801C: 480 mm x 365 mm x 145 mm (without rack and housing) 610 mm x 380 mm x 200 mm (with rack and housing)
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Weight (kg)
Specification
BBU3900: in full configuration: 11; in 3 x 2 configuration: 7 RRU3801C: 20
Input power
RRU3801C: 48 V DC, voltage range: 40 V DC to 60 V DC 220 V AC, voltage range: 150 V AC to 300 V AC BBU3900: +24 V DC, voltage range: +21.6 V DC to +29 V DC 48 V DC, voltage range: 38.4 V DC to 57 V DC
Power consumption
Power consumption
Power backup duration in typical power estimated on the basis of the battery capacity Maximum power consumption (W) (100% load) 24 Ah 50 Ah 100 Ah
Configuration
540 W 680 W
620 W 830 W
BBU3900: 20C to +55 C RRU3801C: 40C to +50 (with 1120 W/m2 solar radiation) C 40C to +55 (without solar radiation) C
Relative humidity
Absolute humidity Air pressure Protection degree Storage Transportation Anti-seismic performance
RRU3801C: (130) g/m 70 kPa to 106 kPa BBU3900: IP20 RRU3801C: IP65
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations" ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
EMC
Specification
The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.
Specification
Band Band I (2100 MHz) Band II (1900 MHz) Band V /VI (850 MHz) Band IV (AWS) 17101755 21102155 824849 869894 18501910 19301990 RX band (MHz) 19201980 TX band (MHz) 21102170
Capacity
Output power
A single RRU3804 supports up to four carriers with a 60 W output power at the antenna connector with four carriers.
One-carrier configuration: 50 W per carrier Two-carrier configuration: 30 W per carrier (20 W per carrier in 1001 configuration) Three-carrier configuration: 20 W per carrier Four-carrier configuration: 15 W per carrier1
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Receiver sensitivity
Specification
Band 1-way receiver sensitivity (dBm) Band I (2100 MHz) 125.8 2-way receiver sensitivity (dBm) 128.6 As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. Remarks
126.5
129.3
125.3
128.1
126.0
128.8
Receiver sensitivity
Other bands
125.6
128.4
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Specification
126.3 129.1 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.001.
Transmission port Clock synchronization Specifications (height x width x depth) Weight (kg)
A maximum of 48 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, and IP clock Precision: 0.05 ppm BBU3900: 86 mm x 442 mm x 310 mm RRU3804: 480 mm x 270 mm x 140 mm (without the housing and connectors) 485 mm x 285 mm x 170 mm (with the housing and connectors) BBU3900: full configuration: 11 typical configuration (1 PSU, 1 WBBP, 1 WMPT): 7 RRU3804: 15 (without the housing) 17 (without the housing)
Input voltage
RRU3804: 48 V DC, voltage range: 36 V DC to 57 V DC BBU3900: +24 V DC, voltage range: +21.6 V DC to +29 V DC 48 V DC, voltage range: 38.4 V DC to 57 V DC Power consumption Power backup duration in typical power estimated on the basis of the battery capacity Maximum power consumption (100% load) 500 W 740 W 970 W 24 Ah 50 Ah 100 Ah
Power consumption
Configuration
BBU3900: 20C to +55 C RRU3804: 40C to +50 (with 1120 W/m2 solar radiation) C 40C to +55 (without solar radiation) C
Relative humidity
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Absolute humidity
Specification
BBU3900: (125) g/m
3 3
RRU3804: (130) g/m Air pressure Protection degree 70 kPa to 106 kPa BBU3900: IP20 RRU3804: IP65 Storage Transportation Anti-seismic performance
ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations". ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation" IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)
EMC
The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.
Specification
Band Band I (2100 MHz) Band II (1900 MHz) RX band (MHz) 19201980 18501910 TX band (MHz) 21102170 19301990
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Specification
Band V/VI (850 MHz) Band IV (AWS) 824849 17101755 869894 21102155
Capacity
Output power
The RRU3801C supports two carriers with a 40 W output power at the antenna connector. The RRU3804 supports four carriers with a 60 W output power at the antenna connector.
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power is measured at the antenna connector of the base station. The output power of the RRU3804 in different configurations is as follows: One-carrier configuration: 50 W per carrier Two-carrier configuration: 30 W per carrier (20 W per carrier in 1001 configuration) Three-carrier configuration: 20 W per carrier Four-carrier configuration: 15 W per carrier
Receiver sensitivity
Band
Remarks
125.8
As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001. The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001. As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna connector on condition that the channel rate reaches 12.2 kbit/s and the BER is within 0.001.
Receiver sensitivity
126.5
129.3
Other bands
125.6
128.4
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Specification
126.3 129.1 The receiver sensitivity (median performance over reception bandwidth) is tested at the antenna connector. The AMR service should be at 12.2 kbit/s and the BER should not exceed 0.0001.
Optical/ electrical Clock synchronization Specifications (height x width x depth) Weight (kg)
A maximum of 8 E1s/T1s, 2 FE electrical ports, and 2 FE optical ports Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, and IP clock Precision: 0.05 ppm 600 mm x 400 mm x 390 mm 600 mm x 240 mm x 390 mm (when used as an outdoor BBU)
Input voltage
48 V DC, voltage range: 38.4 V DC to 57 V DC 220 V AC single-phase, voltage range: 176V AC to 290V AC 110 V AC dual-live-wire, voltage range: 176/304 V AC to 290/500 V AC
Power consumption
With RRU3801C Configuration 3x1 With RRU3804 Configuration 3x1 Typical power consumption 300 W 360 W
2
3x2
-40 to +45C (with 1120 W/m solar radiation) C -40 to +50C (without solar radiation) C
Relative humidity Absolute humidity Air pressure Protection degree Storage Transportation
70 kPa to 106 kPa IP55 ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weatherprotected, not temperature-controlled storage locations". ETSI EN300019-1-2 V2.1.4 (2003-04) class 2.3 "Public transportation"
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Item
Anti-seismic performance
Specification
IEC 60068-2-57 (1999-11) Environmental testing Part 2-57: Tests Test Ff: Vibration Time-history method. YD5083-99: Interim Provisions for Test of Anti-seismic Performances of Telecommunications Equipment (telecom industry standard in People's Republic of China)
EMC
The NodeB meets the EMC requirements and complies with the following standards:
CISPR 22 (1997) EN 55022 (1998) CISPR 24 (1998) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-29 GB 9254-1998 ETSI 301 489-1 V1.3.1 (2001-09) FCC Part 15
The NodeB passes the certification of European standards.
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
8
APM ATM BBU BER CPRI DAGC FE HSDPA HSUPA IP LTE PDU PMU PSU RNC WRRU TCO UEIU UELP UFAN UFLP UPEU
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59
Full Spelling
Universal Satellite card and Clock Unit Universal Transmission Processing unit WCDMA BaseBand Process unit WCDMA Main Processing&Transmission unit WCDMA Radio Filter Unit
03 (2008-09-18)
COMMERCIAL IN CONFIDENCE
Page 43 of 59