Sunteți pe pagina 1din 13

F6L

Technical Data Sheet


M B K

P/N 0518257_A NSF Certified


November 2010

N D L M F E
We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.

A H J C N I G
Item Part # Description Wiring Item #

Item Part #

Description

Wiring Item #

FAN ASSEMBLIES, AND THERMOSTATS A. 12W Standard Fan Assembly


Fan Motor, Evaporator (MO.4410311) Fan Blade (FB.4780620) embossing toward motor 12W Energy Efficient Fan Assembly 0477655 Fan Motor, Evaporator (MO.4410546) 0142780 Fan Blade (FB.0142780) embossing toward motor 0404551 Fan Motor Muffin, Ambient 120V, 15W, CW (MO.0404551) 0440420 Fan Motor, Reversing Non-Refrigerated (Electric Defrost) 120V, 9W, CW (MO.4410302) 0141070 Fan Blade (FB.0141070) embossing toward motor 0058698 Fan Motor, Non-Refrigerated (Gas Defrost) 120V, 7W, CW (MO.4410102) 0141070 Fan Blade (FB.0141070) embossing toward motor 0474130 Standard Non-Adjustable Bi-metal Electric Defrost Thermostat (CT.4440737) 0358566 Optional Non-Adjustable Bi-metal Gas Defrost Thermostat (CT.0358566) Optional Adjustable Refrigeration Thermostat 0047000 0413031 (1)

ELECTRIC DEFROST HEATERS (CONTINUED)


I. Defrost Heater 0486060 0486061 0486062 0486063 (9) 4 ft (HE.4851042) 6 ft (HE.4850669) 8 ft (HE.4850692) 12 ft (HE.4850653)

(1)

ANTI-SWEAT HEATERS
J. (2) (3) Return Air Heater 0486052 4 ft, (HE.4850701) 0486053 6 ft, (HE.4850702) 0486054 8 ft, (HE.4850627) 0486055 12 ft, (HE.4850660) K. Main Anti-Sweat Heater (Honeycomb Divider) 0494989 4 ft (HE.4850723) 0494990 6 ft (HE.4850724) 0494991 8 ft (HE.4850725) 0494992 12 ft (HE.4850726) L. Optional Front Rail Heater 0494998 4 ft (HE.4850727) 0494999 6 ft (HE.4850728) 0495000 8 ft (HE.4850729) 0495001 12 ft (HE.4850730) (10)

B. C.

(11)

(3)

(12)

D.

(4)

E.

(5)

LAMPS AND BALLASTS


M. 0466233 0466234 0466235 N. Ballast, Electronic 1 lamp (BA.4481300) 2 lamps (BA.4480823) 3 lamps (BA.4480901) Fluorescent Lamp Replace with like fixtures (13)

ELECTRIC DEFROST HEATERS


F. G. H. 0123592 0442232 Defrost Heater 0487482 0495023 Relay, DPDT 208V coil (RL.4440495) Heater Limit Thermostat (CT.4481090) (8) 4, 8 & 12 ft (HE.4481533) 6 ft (HE.4850742) (6) (7)

(14)

2010 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N_0518257_A

Engineering

PHYSICAL DATA
Merchandiser Drip Pipe (in.) Merchandiser Liquid Line (in.) Merchandiser Suction Line (in.) Dimensions shown as inches & (mm). 1 1/2 3/8 1 1/8

Plan Views
F6L Frozen
06-2010

A B C 29 1/2 35 3/8
(899) Waste Outlet

27 1/2
(699) Refrigeration Outlet

(749)

30 5/8
(778)

38 5/8
(981)

4
(102) Wireway Water Seal (See Note*) Front

8 (203) D

46 1/2
(1182)

4 ft General (A) Case Length (without ends or partitions) 48 1/4 (1226) 1/2 inch to lineup. NOTE: Each end or insulated partition adds 1 Maximum O/S dimension back to front (with bumper) 46 1/2 (1182) Back of case to front of splashguard 38 5/8 (981) Width of skid rail 4 1/8 (105) RH end of case to outside edge of external support 1 3/8 (35) Distance between inside edges of external support and center support NA Distance between inside edges of center supports NA Distance between inside edges of external supports 37 (940) Stub-up area between front skid rail and splashguard 8 (203)

6 ft 72 1/4 (1835) 46 1/2 (1182) 38 5/8 (981) 4 1/8 (105) 1 3/8 (35) 28 1/2 (724) NA NA 8 (203)

8 ft 96 3/8 (2448) 46 1/2 (1182) 38 5/8 (981) 4 1/8 (105) 1 3/8 (35) 40 1/2 (1029) NA NA 8 (203) 88 3/8 (2245) 35 3/8 (899) 34 5/8 (879) 72 1/4 (1835) 27 1/2 (699)

12 ft 144 1/2 (3670) 46 1/2 (1182) 38 5/8 (981) 4 1/8 (105) 1 3/8 (35) 40 1/2 (1029) 43 7/8 (1114) NA 8 (203) 138 7/8 (3527) 35 3/8 (899) 34 5/8 (879) 72 1/4 (1835) 27 1/2 (699)

Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of farthest knockout 40 1/4 (1022) 64 1/4 (1632) Back of case to center of end knockout 35 3/8 (899) 35 3/8 (899) 5/8 (879) 34 5/8 (879) Length of electrical wireway 34 Waste Outlet (C) RH End of case to the center of waste outlet Back O/S of case to center of waste outlet Water Seal Edge of water seal to center of waste outlet Schedule 40 diameter drip pipe (Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.) Refrigeration Outlet Back of case to center of refrigeration outlet (D) RH end of case to center of refrigeration outlet 24 1/8 (613) 27 1/2 (699) 48 1/8 (1222) 27 1/2 (699)

4 (102) 1 1/2 (38)

4 (102) 1 1/2 (38)

4 (102) 1 1/2 (38)

4 (102) 1 1/2 (38)

30 5/8 (778) 9 (229)

30 5/8 (778) 9 (229)

30 5/8 (778) 9 (229)

30 5/8 (778) 9 (229)

2 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

Multi-Deck, 6 Display Levels Excel


Dimensions are shown as inches & (mm).

F6L

Multi-Deck Frozen Food REFRIGERATION DATA

45 5/8
(1159)

F6L
7 1/2 (191)

Note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H. F6L Discharge Air (F) Evaporator (F) Unit Sizing (F) Btu/hr/ft** Parallel 8 16 19 F6L 1755 1850 F6L* 3 9 12 F6L* 1660 1750

49 5/8
(1260)

22
(559)

Conventional * = Non-0 Return Code

55 1/4
(1403)

Optional energy efficient motors reduce the

53
(1346)

refrigeration load by 55 Btu/hr/ft.

81 1/4 (2064)

DEFROST DATA
Frequency (hr) Defrost Water (lb/ft/day) F6L 8 8.6

Optional Bottom Wire Rack

14 (355) 16 (406) 18 (457) 12 (305) 6 (152) 7 2 (51) 25 /8 (657)


Refrigeration Outlet

C O I L

( 15% based on case configuration and product loading).

ELECTRIC REVERSE AIR DEFROST


Temp Term (F) Failsafe (minutes) 60 30

GAS DEFROST

23
(584)

FAN

Temp Term (F) Failsafe (minutes)

NA 22 NA

OFFTIME

5 1/2
(139)

CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO (Temp F)** F6L 20/ 39

7 5/8
(194)

41/8 (101) 27 1/2 (699) 29 1/2 (749) 30 5/8 (778) 35 3/8 (899) 38 5/8 (981) 46 1/2 (1182)

Indoor Unit Only, Pressure Defrost Termination (Temp F)** 48 **Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge *** 4 ft 6 ft 8 ft 1.8 lb 2.5 lb 3.5 lb 29 oz 40 oz 56 oz F6L 0.8 kg 1.1 kg 1.6 kg

NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability.

12 ft 5.1 lb 82 oz 2.3 kg ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg).

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

3 of 13

Excel

F6L
4 ft 2 1 1 6 ft 4 2 2 8 ft 4 2 2 12 ft 6 3 3 Watts 6 ft 8 ft 200 228 72 44 48 50 56 78 84 200 228 72 44 48 50 56 78 84

Multi-Deck Frozen Food

Electrical Data
Number of Fans Main Evaporator Ambient Non-Refrigerated

4 ft

Amperes 6 ft 8 ft

12 ft

4 ft 100 114 36 22 24 25 28 39 42

12 ft 300 342 108 66 72 75 84 117 126

Main Evaporator Fans (12W) 120V 60Hz Standard 1.30 2.60 2.60 3.90 120V 50Hz Standard 1.50 3.00 3.00 4.50 120V 60 Hz Energy Efficient 0.60 1.20 1.20 1.80 Ambient Fans (15W) 120V 60Hz Standard 0.25 0.50 0.50 0.75 120V 50Hz Standard 0.29 0.58 0.58 0.87 Non-Refrigerated Fan (9W, Reversing ) Standard Electric Defrost Only 120V 60Hz Standard 0.24 0.48 0.48 0.72 120V 50Hz Standard 0.27 0.54 0.54 0.81 Non-Refrigerated Fans (7W) Optional Gas Defrost Only 120V 60Hz Standard 0.50 1.00 1.00 1.50 120V 50Hz Standard 0.55 1.10 1.10 1.65 Anti-Sweat Heaters Constant On Main Divider Anti-sweat Heaters Return Grill Air Heaters

0.75 0.83

1.00 1.25

1.50 1.67

2.25 2.50

90 100

120 150

180 200

270 300

Minimum Circuit Ampacity Standard Electric Defrost 120V 60Hz Standard 3.57 6.03 120V 50Hz Standard 3.84 6.57 120V 60 Hz Energy Efficient 2.87 4.63 Minimum Circuit Ampacity Optional Gas Defrost 120V 60Hz Standard 3.83 6.55 120V 50Hz Standard 4.12 7.13 120V 60 Hz Energy Efficient 3.13 5.15 Optional Hand Rail Anti-Sweat Heater 120V 0.56 Maximum Over Current Protection 120V Maximum Over Current Protection 230V Electric Defrost Heaters 208V 1ph Modular U-Shaped Full Length Rod Total Defrost Heaters Standard Lighting (T-8 fluorescent) 1 Row Canopy & 1 Row Rail Optional Lighting (T-8 fluorescent) 2 Row Canopy & 1 Row Rail 20 NA 0.78 20

6.95 7.49 5.55

10.32 11.13 8.22

7.47 8.05 6.07 1.11 20

11.10 11.97 9.00 1.67 20 67 94 133 200

3.29 4.71 8.00

4.76 7.07 11.83

6.58 9.42 16.00

9.87 14.15 24.02

685 980 1665

990 1470 2460

1370 1960 3330

2055 2943 4998

0.52

1.00

1.00

1.50

62

120

120

184

0.76

1.50

150

2.25

92

180

180

231

4 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

Excel

F6L

Multi-Deck Frozen Food

Product Data
Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft)
1 2 3

7.73 ft3 /ft (0.72 m3 /m) 4.07 ft2 /ft (1.24 m2 /m) 11.32 ft2 /ft (3.45 m2 /m)

AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m] Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (4) rows of 22-inch shelves and (1) row of 18-inch shelves.

ESTIMATED SHIPPING WEIGHT 4


Case 4 ft lb (kg)
4 Actual

Solid End 6 ft 1300 ( 590 ) 8 ft 1700 ( 771 ) 12 ft 2000 ( 907 ) (each) 100 ( 45 ) 1000 ( 454 )

weights will vary according to optional kits included.

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

5 of 13

Electric Defrost Fans & Anti-Sweat Heaters

4 ft Wiring Diagram
Ambient Air Curtain - Muffin Fan

15W

11

Main Anti-Sweat Heater (Honeycomb Divider)


90W 4-pass Foil Bond

Main Evaporator Fans

12W

Reversing Non-Refrigerated Fan

9W

6 Relay
BK R BR

10 100W - 1 pass Tubular Heater

Return Air Heater

12

Optional Stainless Steel Front Rail Heater, 67W

Brown & Purple 120V Neutral 120V Power

Fans and Anti-sweat Heaters

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black BR = Brown W = White

6 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

4 ft Wiring Diagram Lighting Circuit


Ballast mounted next to muffin fans left and center of canopy area

Standard Electric Light Circuit

13 14
T-8 Ballast

13 14

T-8 ballast mounted in lower wireway

13 14
Front Rail Light Switch 200W

Orange 120V Neutral

Lights

120V Power

Defrost Circuit
1 8 U-Shaped Rod Mod. Defrost Heater 685W 2

Standard Electric Defrost Circuit

1 9 Defrost (Rod) Heater


980W
90 Open on Rise

7 Thermostat

Heater Limit

2 6 Reversing Relay
220V Holding Coil

Refrigeration and Defrost Controls


Optional

(Mounted above
left-hand rear coil) Defrost Terminator - 60

5 Refrigeration
Thermostat

4
10A

10A

Red L-1 220V Power from Defrost Contactor L-2

Pink Dark Blue

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

7 of 13

Electric Defrost Fans & Anti-Sweat Heaters

6, 8, & 12 ft Wiring Diagram


Ambient Air Curtain - Muffin Fans

15W

12 ft case shown in gray lines

11

Main Anti-Sweat Heater (Honeycomb Divider)

4-pass Foil Bond 270W 12 ft, 180W - 8 ft, 120W - 6 ft

1 Main Evaporator Fans

12 ft case shown in gray lines 12W

Reversing Non-Refrigerated Fans

12 ft case shown in gray lines 9W

6 Relay
BK R BR

Return Air Heater 1 pass Tubular Heater 300W - 12 ft, 200W - 8 ft, 150W - 6 ft

10

Front Rail Heater 200W - 12 ft, 133W - 8 ft, 94W - 6 ft

12 Optional Stainless Steel

Brown & Purple 120V Neutral 120V Power

Fans and Anti-sweat Heaters

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Grayed components in 12 foot models only R = Red Y = Yellow G = Green BL = Blue BK = Black BR = Brown W = White

8 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

6, 8, & 12 ft Wiring Diagram Lighting Circuit


Ballast mounted next to muffin fans left and center of canopy area

Standard Electric Light Circuit

13 14
T-8 Ballast

14

14

12 ft case shown in gray lines

13 14 14 14

T-8 ballast mounted in lower wireway

13 14
Front Rail Light Switch

14

14

12 ft case shown in gray lines

Orange 120V Neutral

Lights

120V Power

Defrost Circuit
1 1 1 1 9
Defrost (Rod) Heater 2943W - 12 ft 1960W - 8 ft 1470W - 6 ft
90 Open on Rise

U-Shaped Rod Modular Defrost Heaters

2
685W ea 4 ft Tubular Heater 495W ea 3 ft Tubular Heater

2 2

Standard Electric Defrost Circuit

(12 ft Case Only)

7 Heater Limit
Klixon mounted on right-hand plenum between fans

Thermostat 2

Refrigeration and Defrost Controls


Optional 5 Refrigeration Thermostat

6 Reversing Relay
220V Holding Coil 10A

(Mounted above left-hand rear coil)


Defrost Terminator - 60

4
10A

Red L-1 220V Power from Defrost Contactor L-2

Pink Dark Blue

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Grayed components in 12 foot models only R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

9 of 13

Gas Defrost Fans & Anti-Sweat Heaters

4 ft Wiring Diagram
Ambient Air Curtain - Muffin Fan

15W

11

Main Anti-Sweat Heater (Honeycomb Divider)


90W 4-pass Foil Bond

Main Evaporator Fans

12W

Non-Refrigerated Fan

7W

10 100W - 1 pass Tubular Heater

Return Air Heater

12

Optional Stainless Steel Front Rail Heater, 67W

Brown & Purple 120V Neutral 120V Power

Fans and Anti-sweat Heaters

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

10 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

4 ft Wiring Diagram Lighting Circuit


Ballast mounted next to muffin fans left and center of canopy area

Gas Defrost Light Circuit & Thermostat

13 14
T-8 Ballast

13 14

T-8 ballast mounted in lower wireway

Optional Refrigeration Thermostat

13 14
Front Rail Light Switch

Orange 120V Neutral

Pink 120V Power

Lights

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

11 of 13

Gas Defrost Fans & Anti-Sweat Heaters

6, 8, & 12 ft Wiring Diagram


Ambient Air Curtain - Muffin Fans

15W

12 ft case shown in gray lines

11

Main Anti-Sweat Heater (Honeycomb Divider)

4-pass Foil Bond 270W 12 ft, 180W - 8 ft, 120W - 6 ft

Main Evaporator Fans

12 ft case shown in gray lines 12W

Non-Refrigerated Fans

12 ft case shown in gray lines 7W

Return Air Heater 1 pass Tubular Heater 300W - 12 ft, 200W - 8 ft, 150W - 6 ft

10

Front Rail Heater 200W - 12 ft, 133W - 8 ft, 94W - 6 ft

12 Optional Stainless Steel

Brown & Purple 120V Neutral 120V Power

Fans and Anti-sweat Heaters

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Grayed components in 12 foot models only R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

12 of 13

U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900

F6L Technical Data Sheet

6, 8, & 12 ft Wiring Diagram Lighting Circuit


Ballast mounted next to muffin fans left and center of canopy area

Gas Defrost Light Circuit & Thermostat

13 14
T-8 Ballast

14

14

12 ft case shown in gray lines

13 14 14 14

T-8 ballast mounted in lower wireway

12 ft case shown in gray lines

Optional Refrigeration Thermostat

13 14
Front Rail Light Switch 200W

5 14 14

Orange

Pink

120V Neutral

Lights

120V Power

WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Grayed components in 12 foot models only R = Red Y = Yellow G = Green BL = Blue BK = Black W = White

P/N 0518257_A

HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM

13 of 13

S-ar putea să vă placă și