21 S. No.

Items

CHAPTER-IV

Unit

Rates (Rs.)

REINFORCED CEMENT CONCRETE


NOTES : 1. Cement : Cement to be used in the works shall be any of the following types with the prior approval of the Engineer-in-Charge : a) Ordinary portland cement, 33 Grade conforming to IS : 269. b) Ordinary portland cement, 43 Grade conforming to IS : 8112. c) Ordinary portland cement, 53 Grade conforming to IS : 12269. d) Sulphate resistant portland cement, conforming to IS : 12330. 2. Steel : Steel to be used shall conform to IS : 1786. All steel shall be procured from original producers, no re-rolled steel shall be incorporated in the work. Only new steel shall be delivered to the site. Every bar shall be inspected before asssembling on the work and defective, brittle or burnt bar shall be discarded. Cracked ends of bars shall be discarded. 3. Coarse Aggregates : Coarse aggregate shall consist of clean, hard, strong, dense, non-poros and durable pieces of crushed stone. They shall not consist pieces of disintegrated stones, soft, flaky, elongated particles, salt, alkali, vegetable matter or other deleterious materials. All coarse aggregate shall conform to IS : 383 and tests for conformity shall be carried out as per IS : 2386 parts I to VIII. The maximum value of Flakiness Index for coarse aggregate shall not exceed 35 percent. The coarse aggregate shall satisfy the following requirements of grading :

22 S. No. Items Unit Rates (Rs.)

Grading Requirements of Coarse Aggregate

IS Sieve 40mm 63mm 40mm 20mm 12.5mm 10mm 4.75 4. 100 95-100 30-70 10-35 0-5

Percent by weight passing the sieve 20mm 12.5mm 100 95-100 25-55 0-10 100 90-100 40-85 0-10

Sand/Fine Aggregates Fine aggregates shall not contain dust, lumps, soft or flaky materials, mica or other deleterious materials. Fine aggregates, having positive alkali-silica reaction, shall not be used. All fine aggregates shall conform to IS : 383. The fineness modulus of fine aggregate shall neither be less than 2.0 nor greater than 3.5.

5.

Water : Water used for mixing and curing shall be clean and free from injurious amount of oils, acids, alkalis, salts, sugar, organic materials or other substances that may be deleterious to concrete. Potable water is generally considered satisfactory for mixing and curing of concrete.

6.

Concrete : Concrete shall be mixed either in a concrete mixer or in a batching and mixing plant. Hand mixing is prohibited. Mixing shall be continued till materials are uniformly distributed and a uniform colour of the entire mass is obtained and each individual particle of the coarse aggregate shows complete coating of mortar, containing its proportionate amount of cement. In no case, mixing shall be done for less than 2 minutes.

23

Concrete shall be transported and placed as near as practicable to its final S. No. Items Unit Rates (Rs.) position. Concrete shall not be freely dropped into place from a height exceeding 1.50metres and it shall be compacted in its final position within 30 minutes of its discharge from the mixer. It shall be compacted thoroughly by vibration or other means during placing so as to produce a dense homogeneous void-free mass having the required surface finish . Bottom and side surfaces shall give a uniform texture, smooth surface and good appearance. Non uniform texture and rough surface of concrete shall be treated as defective work and it has to be remedied with 1:3 cement plaster.
S. No. Items 1. Providing and laying mechanically mixed reinforced cement concrete excluding centering, shuttering and reinforcement in foundations, plinth and in superstructure upto a height of 4.0 m. above plinth level. a) M-15 b) M-20 c) M-25 d) M-30 Providing and laying cement concrete for prestressed concrete of M-35 grade in superstructure including, centering & form work complete as per drawings and specifications. Add extra for precast R.C.C. work, any mix including centering shuttering and fixing in C.M. 1:2 (1 Cement:2Sand) finished with cement plaster in cement mortar 1:3 Providing and laying 25mm. thick eve board in C.M. 1:3 (1 Cement :3 Sand) including providing necessary supports and including cost of centering and chicken mesh etc. but excluding cost of reinforcements. Encasing rolled steel sections in beams and columns with C.C. M-15 grade (20 mm metal) upto 4.0m. height above plinth level Unit Rates (Rs.)

Cum. Cum. Cum. Cum. Cum.

1600.00 1770.00 2300.00 2450.00 3750.00

2.

3.

Cum.

995.00

4.

Cum.

4000.00

5.

Cum.

2135.00

24 S. No. Items including centering etc. complete. 6. Encasing rolled steel sections to grillages with C.C. M-15 grade (20 mm metal) upto 4.0m. height, above plinth level including centering, shuttering but excluding cost of expanded metal and hangers. Add extra for providing and fixing expanded metal mesh of size 20mm x 60mm and strands 3mm wide, 1.6mm thick, weighing 2.64 kg. per Sqm. for encasing of rolled steel section in beams, columns and grillages but excluding cost of hangers Providing and placing in position cold twisted steel and hot rolled deformed steel reinforcement for R.C.C. work including cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all wastages etc. complete. Hard drawn steel wire fabric for R.C.C. work Add extra for every 0.50 M. height or part thereof, for a height beyond 4.0 M above plinth level for all R.C.C. work. Add extra for rendering smooth, the top of suspended floors, landings, and stair case with C.M. 1:2 including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm. of earth, laid over 13mm. fine sand, in case of suspended floor and bricks laid in mud mortar on landing and steps including subsequent removal of and cleaning same. Applying cement slurry on R.C.C. Slab or cement concrete work using 2.75 kg/Sqm. for receiving cement concrete floor including roughening, cleaning etc complete. Cum. 1620.00 Unit Rates (Rs.)

7.

Sqm.

80.00

8.

Kg.

24.00

9. 10.

Kg. Cum.

24.00 0.20 % of rate of concrete 23.00

11.

Sqm.

12.

Sqm.

9.00

25 S. No. Items 13. Providing precast cement concrete jalli 1:2:4 reinforced with 6mm. dia. mild steel wire including roughening, cleaning, fixing and finishing in CM 1:3 etc. complete, excluding plastering of jambs, sills and soffits, for all floors a) 40 mm thick to 50mm thick b) 25 mm thick. Providing and filling in position, blown bitumen in expansion joints per cm. depth and per cm. width Providing and fixing in position copper plate as per design for expansion joints. Providing and fixing in position impregnated fibre board in expansion joints, per cm. depth. a) 12 mm thick b) 25 mm thick Providing and fixing 6 mm. thick 15 cm wide asbestos sheet covering over expansion joints. Add extra for laying reinforced cement concrete, in or under water, liquid mud including cost of pumping or bailing out water and removing slush Add extra for laying reinforced cement concrete, in or under foul positions Providing throating or plastering drip and moulding to R.C.C. chajja and balconies Providing and fixing aluminium strip 1.60 mm thick on expansion joints including, cutting, rivetting, fixing etc. complete. Unit Rates (Rs.)

Sqm. Sqm. RM

195.00 160.00 1.05

14.

15. 16.

Kg.

280.00

RM RM RM Cum/M depth

4.25 8/.50 34.00 124.00

17. 18.

19. 20. 21.

Cum. RM Sqm.

31.00 15.00 450.00