Sunteți pe pagina 1din 698

ExtremeWare XOS Concepts Guide

Software Version 11.3

Extreme Networks, Inc. 3585 Monroe Street Santa Clara, California 95051 (408) 579-2800 (888) 257-3000 http://www.extremenetworks.com Published: September 2005 Part number: 100194-00 Rev 01

Alpine, Altitude, BlackDiamond, EPICenter, Ethernet Everywhere, Extreme Ethernet Everywhere, Extreme Networks, Extreme Turbodrive, Extreme Velocity, ExtremeWare, ExtremeWorks, GlobalPx Content Director, the Go Purple Extreme Solution Partners Logo, ServiceWatch, Summit, the Summit7i Logo, and the Color Purple, among others, are trademarks or registered trademarks of Extreme Networks, Inc. or its subsidiaries in the United States and other countries. Other names and marks may be the property of their respective owners. 2005 Extreme Networks, Inc. All Rights Reserved. Specifications are subject to change without notice. The ExtremeWare XOS operating system is based, in part, on the Linux operating system. The machine-readable copy of the corresponding source code is available for the cost of distribution. Please direct requests to Extreme Networks for more information at the following address: Software Licensing Department 3585 Monroe Street Santa Clara CA 95051 NetWare and Novell are registered trademarks of Novell, Inc. Merit is a registered trademark of Merit Network, Inc. Solaris and Java are trademarks of Sun Microsystems, Inc. F5, BIG/ip, and 3DNS are registered trademarks of F5 Networks, Inc. see/IT is a trademark of F5 Networks, Inc. sFlow is a registered trademark of InMon Corporation.

All other registered trademarks, trademarks and service marks are property of their respective owners. 123456789

Authors: Hugh Bussell, Megan Mahar, Peggy Murphy Production: Hugh Bussell

ExtremeWare XOS 11.3 Concepts Guide

Contents
Preface......................................................................................................................................... 21
Introduction .............................................................................................................................21 Terminology........................................................................................................................21 Conventions..............................................................................................................................22 Platform-Dependent Conventions ..........................................................................................22 Text Conventions.................................................................................................................22 Related Publications .................................................................................................................23 Using ExtremeWare XOS Publications Online .........................................................................23

Part 1: Using ExtremeWare XOS


Chapter 1: ExtremeWare XOS Overview........................................................................................... 27
Platforms and Required Software Versions ...................................................................................27 Summary of Features.................................................................................................................27 Feature Highlights of ExtremeWare XOS 11.3 ........................................................................28 Software Licensing ....................................................................................................................33 Upgrading on the BlackDiamond 10K Switch Only .................................................................34 Obtaining a License Voucher ................................................................................................35 Enabling and Verifying Licenses ...........................................................................................35 Security Licensing...............................................................................................................35 Software Factory Defaults ..........................................................................................................36

Chapter 2: Accessing the Switch.................................................................................................... 39


Understanding the Command Syntax...........................................................................................39 Syntax Helper .....................................................................................................................40 Command Shortcuts ............................................................................................................41 Names ...............................................................................................................................41 Symbols .............................................................................................................................41 Limits ................................................................................................................................42 Port Numbering ........................................................................................................................42 Stand-alone Switch Numerical Ranges ..................................................................................43 Modular Switch Numerical Ranges........................................................................................43 Line-Editing Keys......................................................................................................................43 Command History......................................................................................................................44 Common Commands..................................................................................................................44 Accessing the Switch the First Time............................................................................................46 Safe Defaults Setup Method.................................................................................................47 Configuring Management Access ................................................................................................47 User Account ......................................................................................................................48 Administrator Account .........................................................................................................48 Default Accounts.................................................................................................................48 Creating a Management Account...........................................................................................49 Failsafe Account .................................................................................................................49

ExtremeWare XOS 11.3 Concepts Guide

Contents Managing Passwords .................................................................................................................50 Applying a Password to the Default Account ..........................................................................50 Applying Security to Passwords.............................................................................................51 Displaying Passwords...........................................................................................................52 Access to Both MSM Console PortsModular Switches Only.........................................................53 Domain Name Service Client Services .........................................................................................53 Checking Basic Connectivity.......................................................................................................54 Ping...................................................................................................................................54 Traceroute ..........................................................................................................................55 Displaying Switch Information ....................................................................................................56

Chapter 3: Managing the Switch .................................................................................................... 59


Overview ..................................................................................................................................59 Understanding the ExtremeWare XOS Shell .................................................................................60 Using the Console Interface .......................................................................................................60 Using the 10/100 Ethernet Management Port ..............................................................................61 Using EPICenter to Manage the Network .....................................................................................61 Authenticating Users .................................................................................................................62 RADIUS Client ....................................................................................................................62 TACACS+ ...........................................................................................................................62 Management Accounts.........................................................................................................62 Using Telnet .............................................................................................................................62 About the Telnet Client ........................................................................................................63 About the Telnet Server .......................................................................................................63 Connecting to Another Host Using Telnet...............................................................................64 Configuring Switch IP Parameters .........................................................................................64 Configuring Telnet Access to the Switch ................................................................................66 Disconnecting a Telnet Session ............................................................................................68 Using Secure Shell 2.................................................................................................................69 Using the Trivial File Transfer Protocol ........................................................................................69 Connecting to Another Host Using TFTP ................................................................................69 Understanding System Redundancy with Dual MSMs InstalledModular Switches Only ..................70 Node Election .....................................................................................................................70 Replicating Data Between Nodes ..........................................................................................72 Viewing Node Status............................................................................................................73 Understanding Hitless Failover SupportModular Switches Only...................................................74 Protocol Support for Hitless Failover .....................................................................................74 Platform Support for Hitless Failover.....................................................................................77 Hitless Failover Caveats .......................................................................................................78 Understanding Power Supply Management ..................................................................................78 Using Power SuppliesModular Switches Only ......................................................................79 Using Power SuppliesSummit X450 Switch Only ................................................................81 Displaying Power Supply Information ....................................................................................82 Using the Simple Network Management Protocol .........................................................................82 Enabling and Disabling SNMPv1/v2c and SNMPv3 ................................................................83 Accessing Switch Agents......................................................................................................84 Supported MIBs ..................................................................................................................84 Configuring SNMPv1/v2c Settings ........................................................................................84 Displaying SNMP Settings....................................................................................................84

ExtremeWare XOS 11.3 Concepts Guide

Contents SNMPv3.............................................................................................................................85 Message Processing.............................................................................................................86 SNMPv3 Security ................................................................................................................86 SNMPv3 MIB Access Control ...............................................................................................89 SNMPv3 Notification...........................................................................................................90 Using the Simple Network Time Protocol.....................................................................................92 Configuring and Using SNTP ................................................................................................93 SNTP Example....................................................................................................................96

Chapter 4: Managing the ExtremeWare XOS Software...................................................................... 97


Overview of the ExtremeWare XOS Software .................................................................................97 Understanding the ExtremeWare XOS Software ......................................................................97 Using the ExtremeWare XOS File System.....................................................................................98 Moving or Renaming Files on the Switch ...............................................................................98 Copying Files on the Switch .................................................................................................99 Displaying Files on the Switch ............................................................................................100 Deleting Files From the Switch ...........................................................................................101 Managing the Configuration File ...............................................................................................102 Managing ExtremeWare XOS Processes .....................................................................................103 Displaying Process Information...........................................................................................103 Stopping a Process............................................................................................................104 Starting a Process .............................................................................................................105 Understanding Memory Protection ............................................................................................105 Monitoring CPU Utilization.......................................................................................................106 Disabling CPU Monitoring ..................................................................................................106 Enabling CPU Monitoring ...................................................................................................106 Displaying CPU Utilization History ......................................................................................107

Chapter 5: Configuring Slots and Ports on a Switch....................................................................... 109


Configuring a Slot on a Modular SwitchBlackDiamond 10K Switch and BlackDiamond 8800 Family of Switches Only ............................................................................109 Overview...........................................................................................................................109 I/O Ports on BlackDiamond 8810 MSM Module ...................................................................110 I/O Ports on BlackDiamond 8806 MSM Module ...................................................................111 Configuring Ports on a Switch...................................................................................................111 Port Numbering ................................................................................................................112 Enabling and Disabling Switch Ports ...................................................................................113 Configuring Switch Port Speed and Duplex Setting ...............................................................113 Jumbo Frames ........................................................................................................................116 Jumbo Frames on the BlackDiamond 8800 Family of Switches and Summit X450 Switch Only 116 Enabling Jumbo Frames.....................................................................................................116 Path MTU Discovery ..........................................................................................................117 IP Fragmentation with Jumbo Frames..................................................................................117 IP Fragmentation within a VLAN .........................................................................................118 Link Aggregation on the Switch ................................................................................................119 Link Aggregation and Software-Controlled Redundant PortsSummit X450 Switch Only .........120 Dynamic versus Static Load Sharing....................................................................................120 Load-Sharing Algorithms....................................................................................................120 LACPDynamic Link Aggregation.......................................................................................122 Configuring Switch Load Sharing ........................................................................................123

ExtremeWare XOS 11.3 Concepts Guide

Contents Load-Sharing Examples .....................................................................................................125 Displaying Switch Load Sharing..........................................................................................126 Switch Port Mirroring...............................................................................................................129 Switch Port Mirroring on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only .................................................................................................130 Switch Port Mirroring on the BlackDiamond 10K Switch Only................................................131 Switch Port-Mirroring Rules and Restrictions for All Switches ................................................131 Switch Port-Mirroring Examples ..........................................................................................132 Verifying the Switch Port-Mirroring Configuration .................................................................133 Extreme Discovery Protocol ......................................................................................................133 Software-Controlled Redundant Port and Smart Redundancy .......................................................135 Guidelines for Software-Controlled Redundant Ports and Port Groups .....................................136 Configuring Software-Controlled Redundant Ports.................................................................137 Verifying Software-Controlled Redundant Port Configurations.................................................137 Configuring Automatic Failover for Combination PortsSummit X450 Switch Only .......................138 Displaying Port Configuration Information..................................................................................140 Port DisplaySummit X450 Switch Only ............................................................................143 Port DisplayBlackDiamond 8800 Family of Switches Only .................................................144 Port DisplayBlackDiamond 10K Series Switch Only ...........................................................145

Chapter 6: Link Layer Discovery Protocol...................................................................................... 147


Overview ................................................................................................................................147 LLDP Messages ......................................................................................................................148 LLDP Packets ...................................................................................................................148 Transmitting LLDP Messages..............................................................................................149 Receiving LLDP Messages..................................................................................................149 Managing LLDP ......................................................................................................................150 Supported TLVs ......................................................................................................................150 Mandatory TLVs ................................................................................................................152 Optional TLVs ...................................................................................................................152 Configuring LLDP....................................................................................................................156 Enabling and Disabling LLDP .............................................................................................156 Configuring the System Description TLV Advertisement.........................................................156 Configuring LLDP Timers ...................................................................................................157 Configuring SNMP for LLDP ...............................................................................................157 Configuring Optional TLV Advertisements ............................................................................158 Unconfiguring LLDP ..........................................................................................................160 Displaying LLDP Settings.........................................................................................................160 Displaying LLDP Port Configuration Information ...................................................................160 Displaying LLDP Information Detected from Neighboring Ports ..............................................162

Chapter 7: Power Over Ethernet.................................................................................................... 163


Summary of PoE Features ........................................................................................................163 Power Checking for PoE Module ...............................................................................................164 Power Delivery ........................................................................................................................164 Enabling PoE to the Switch ................................................................................................164 Power Reserve Budget Per Slot...........................................................................................164 PD Disconnect Precedence ................................................................................................165 Port Disconnect or Fault ....................................................................................................166 Port Power Reset...............................................................................................................167

ExtremeWare XOS 11.3 Concepts Guide

Contents PoE Usage Threshold.........................................................................................................167 Legacy Devices .................................................................................................................167 PoE Operator Limits ..........................................................................................................168 LEDs......................................................................................................................................168 Configuring PoE ......................................................................................................................169 Enabling Inline Power........................................................................................................169 Reserving Power for a Slot..................................................................................................170 Setting the Disconnect Precedence .....................................................................................170 Configuring the Usage Threshold ........................................................................................171 Configuring the Switch to Detect Legacy PDs .......................................................................172 Configuring the Operator Limit ...........................................................................................172 Configuring PoE Port Labels ...............................................................................................173 Power Cycling Connected PDs ............................................................................................173 Displaying PoE Settings and Statistics ......................................................................................173 Clearing Statistics .............................................................................................................173 Displaying System Power Information..................................................................................173 Displaying Slot PoE Information .........................................................................................176 Displaying Port PoE Information .........................................................................................177

Chapter 8: Status Monitoring and Statistics .................................................................................. 181


Status Monitoring....................................................................................................................181 Viewing Port Statistics .............................................................................................................181 Viewing Port Errors ..................................................................................................................182 Using the Port Monitoring Display Keys .....................................................................................183 Diagnostics.............................................................................................................................184 Running Diagnostics on I/O and Management ModulesModular Switches Only .....................185 Running Diagnostics on the Summit X450 Switch Only ........................................................185 Observing LED Behavior During a Diagnostic Test.................................................................186 Displaying Diagnostic Test Results......................................................................................189 System Health CheckingModular Switches Only ......................................................................189 Understanding the System Health CheckerBlackDiamond 10K Switch Only .........................189 Understanding the System Health CheckerBlackDiamond 8800 Family of Switches Only ......190 Enabling and Disabling Backplane Diagnostic Packets on the Switch .....................................190 Configuring Backplane Diagnostic Packets on the Switch ......................................................191 System Health Check Examples..........................................................................................191 Setting the System Recovery Level............................................................................................193 Configuring System Recovery..............................................................................................193 Configuring Module RecoveryModular Switches Only .........................................................193 Viewing the System Temperature ..............................................................................................195 System Temperature OutputModular Switches Only...........................................................195 System Temperature OutputSummit X450 Switch Only .....................................................196 Power Supply TemperatureModular Switches Only.............................................................196 Fan Tray TemperatureBlackDiamond 10K Switch Only ......................................................197 Event Management System/Logging ..........................................................................................197 Sending Event Messages to Log Targets...............................................................................198 Filtering Events Sent to Targets ..........................................................................................199 Displaying Real-Time Log Messages ....................................................................................207 Displaying Event Logs........................................................................................................207 Uploading Event Logs ........................................................................................................208 Displaying Counts of Event Occurrences ..............................................................................208

ExtremeWare XOS 11.3 Concepts Guide

Contents Displaying Debug Information.............................................................................................209 Logging Configuration Changes...........................................................................................209 Using sFlow............................................................................................................................209 Configuring sFlow..............................................................................................................210 Displaying sFlow Information..............................................................................................213 RMON....................................................................................................................................213 About RMON ....................................................................................................................213 Supported RMON Groups of the Switch ...............................................................................214 Configuring RMON ............................................................................................................216 Event Actions ...................................................................................................................216 Displaying RMON Information ............................................................................................217

Chapter 9: Virtual LANs ............................................................................................................... 219


Overview of Virtual LANs..........................................................................................................219 Benefits ...........................................................................................................................219 Virtual Routers and VLANsBlackDiamond 10K Switch Only................................................220 Types of VLANs.......................................................................................................................220 Port-Based VLANs .............................................................................................................220 Tagged VLANs ..................................................................................................................223 Protocol-Based VLANs .......................................................................................................225 Precedence of Tagged Packets Over Protocol Filters .............................................................227 Default VLAN....................................................................................................................227 VLAN Names ..........................................................................................................................228 Renaming a VLAN .............................................................................................................228 Configuring VLANs on the Switch .............................................................................................229 VLAN Configuration Examples ............................................................................................229 Displaying VLAN Settings.........................................................................................................230 Displaying Protocol Information ..........................................................................................232 Tunneling (VMANs) .................................................................................................................232 Overview...........................................................................................................................232 QoS Queue on Egress Port..................................................................................................234 Guidelines for Configuring VMANs ......................................................................................235 Configuring VMANs ...........................................................................................................235 Displaying VMAN Configurations.........................................................................................238

Chapter 10: Virtual Routers.......................................................................................................... 241


Virtual Routers Overview ..........................................................................................................241 Types of Virtual Routers .....................................................................................................242 Virtual Router Configuration DomainBlackDiamond 10K Switch Only ..................................243 Using Virtual RoutersBlackDiamond 10K Switch Only .............................................................244 Creating Virtual Routers .....................................................................................................244 Configuring Ports to a Single or to Multiple Virtual Router(s) .................................................244 Adding Routing Protocols to a Virtual Router........................................................................245 Displaying Ports and Protocols............................................................................................245 Configuring the Routing Protocols and VLANs ......................................................................246 Virtual Router Configuration Example ........................................................................................246

Chapter 11: Forwarding Database................................................................................................. 249


Overview of the FDB ................................................................................................................249

ExtremeWare XOS 11.3 Concepts Guide

Contents FDB Contents ...................................................................................................................249 How FDB Entries Get Added...............................................................................................250 FDB Entry Types ...............................................................................................................250 FDB Configuration Examples ....................................................................................................251 Adding a Permanent Static Entry ........................................................................................251 Configuring the FDB Aging Time.........................................................................................252 Clearing FDB Entries .........................................................................................................252 Displaying FDB Entries ............................................................................................................252 MAC-Based Security................................................................................................................253 Disabling MAC Address Learning ........................................................................................253 Disabling Egress Flooding ..................................................................................................254 Displaying Learning and Flooding Settings...........................................................................256 Multicast FDB with Multiport EntrySummit X450 Switch and BlackDiamond 8800 Chassis Only.256

Chapter 12: Policy Manager ........................................................................................................ 257


Policy Manager .......................................................................................................................257 Creating and Editing Policies....................................................................................................257 Using the Edit Command ...................................................................................................258 Using a Separate Machine .................................................................................................258 Checking Policies ..............................................................................................................258 Refreshing Policies............................................................................................................259 Applying Policies ....................................................................................................................259 Applying ACL Policies........................................................................................................259 Applying Routing Policies ..................................................................................................260

Chapter 13: Access Lists (ACLs)................................................................................................... 261


ACLs......................................................................................................................................261 ACL Policy File Syntax .......................................................................................................262 Dynamic ACLs ..................................................................................................................268 ACL Evaluation Precedence................................................................................................269 ACL MeteringBlackDiamond 8800 Family and Summit X450 Only .....................................271 Applying ACL Policy Files ........................................................................................................272 Displaying and Clearing ACL Counters .................................................................................273 Example ACL Rule Entries .................................................................................................273

Chapter 14: Routing Policies ....................................................................................................... 279


Routing Policies......................................................................................................................279 Routing Policy File Syntax..................................................................................................279 Applying Routing Policies ..................................................................................................284 Policy Examples ................................................................................................................284

Chapter 15: Quality of Service ..................................................................................................... 289


Overview of Policy-Based Quality of Service ...............................................................................289 Applications and Types of QoS .................................................................................................290 Voice Applications.............................................................................................................290 Video Applications.............................................................................................................290 Critical Database Applications ............................................................................................291 Web Browsing Applications ................................................................................................291 File Server Applications .....................................................................................................291 Configuring QoS......................................................................................................................292

ExtremeWare XOS 11.3 Concepts Guide

Contents Configuring QoS on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only .................................................................................................292 QoS Profiles ...........................................................................................................................293 QoS Profiles on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only .................................................................................................293 QoS Profiles on the BlackDiamond 10K Switch ....................................................................294 Traffic Groupings ....................................................................................................................295 Precedence of Traffic Groupings .........................................................................................295 ACL-Based Traffic Groupings..............................................................................................296 Explicit Class of Service (802.1p and DiffServ) Traffic Groupings ..........................................296 Physical and Logical Groupings ..........................................................................................304 Verifying QoS Configuration and Performance ............................................................................307 Monitoring PerformanceBlackDiamond 10K Switch Only ...................................................307 Displaying QoS Profile Information......................................................................................308 Guidelines for Configuring QoS.................................................................................................309 Egress Traffic Rate LimitingBlackDiamond 8800 Family of Switches and Summit X450 Switch Only. 309 Bi-Directional Rate ShapingBlackDiamond 10K Switch Only....................................................310 Bandwidth Settings ...........................................................................................................311 Configuring Bi-Directional Rate Shaping..............................................................................312

Chapter 16: Security ................................................................................................................... 313


Security Overview....................................................................................................................313 Safe Defaults Mode .................................................................................................................314 MAC Address Security .............................................................................................................315 Limiting Dynamic MAC Addresses.......................................................................................315 MAC Address Lock Down ...................................................................................................317 DHCP Server ..........................................................................................................................318 Enabling and Disabling DHCP ............................................................................................318 Configuring the DHCP Server..............................................................................................319 Displaying DHCP Information .............................................................................................319 Denial of Service Protection .....................................................................................................320 Configuring Simulated Denial of Service Protection ..............................................................320 Configuring Denial of Service Protection ..............................................................................321 Authenticating Users Using RADIUS or TACACS+ ......................................................................322 RADIUS ...........................................................................................................................322 Configuring RADIUS ..........................................................................................................325 TACACS+ .........................................................................................................................330 Secure Shell 2 ........................................................................................................................335 Enabling SSH2 for Inbound Switch Access ..........................................................................335 Using ACLs to Control SSH2 Access ...................................................................................337 Using SCP2 from an External SSH2 Client ..........................................................................338 SSH2 Client Functions on the Switch..................................................................................338 Secure Socket Layer ................................................................................................................339 Enabling and Disabling SSL ...............................................................................................340 Creating Certificates and Private Keys .................................................................................341 Displaying SSL Information ................................................................................................343

10

ExtremeWare XOS 11.3 Concepts Guide

Contents

Chapter 17: Network Login .......................................................................................................... 345


Network Login Overview ...........................................................................................................345 Web-Based, MAC-Based, and 802.1x Authentication............................................................346 Multiple Supplicant Support ..............................................................................................347 Campus and ISP Modes .....................................................................................................348 Network Login and Hitless FailoverModular Switches Only .................................................348 Configuring Network Login .......................................................................................................349 Enabling or Disabling Network Login on the Switch ..............................................................350 Enabling or Disabling Network Login on a Specific Port ........................................................350 Configuring the Move Fail Action ........................................................................................350 Displaying Network Login Settings ......................................................................................350 Exclusions and Limitations.................................................................................................351 Authenticating Users ...............................................................................................................351 Creating User Accounts on the RADIUS Server.....................................................................351 Configuring Local Database Authentication ..........................................................................355 802.1x Authentication.............................................................................................................359 Interoperability Requirements.............................................................................................359 Enabling and Disabling 802.1x Network Login .....................................................................360 802.1x Network Login Configuration Example......................................................................361 Configuring Guest VLANs ...................................................................................................361 Post-authentication VLAN Movement ..................................................................................363 Web-Based Authentication .......................................................................................................363 Enabling and Disabling Web-Based Network Login ...............................................................364 Configuring the Base URL ..................................................................................................364 Configuring the Redirect Page ............................................................................................364 Configuring Session Refresh ...............................................................................................365 Configuring Logout Privilege...............................................................................................365 Web-Based Network Login Configuration Example ................................................................365 Web-Based Authentication User Login.................................................................................367 MAC-Based Authentication ......................................................................................................368 Enabling and Disabling MAC-Based Network Login ...............................................................369 Associating a MAC Address to a Specific Port ......................................................................369 Adding and Deleting MAC Addresses...................................................................................369 Displaying the MAC Address List ........................................................................................370 Secure MAC Configuration Example ....................................................................................370 MAC-Based Network Login Configuration Example................................................................371 Additional Network Login Configuration Details ..........................................................................371 Configuring Netlogin MAC-Based VLANsBlackDiamond 8800 Family of Switches and the Summit X450 Switch Only .............................................................................................................372

Chapter 18: CLEAR-Flow .............................................................................................................. 375


Overview ................................................................................................................................375 Configuring CLEAR-Flow ..........................................................................................................375 Displaying CLEAR-Flow Configuration and Activity................................................................376 Adding CLEAR-Flow Rules to ACLs ...........................................................................................376 CLEAR-Flow Rule Match Type ............................................................................................377 CLEAR-Flow Rule Match Conditions....................................................................................378 CLEAR-Flow Rule Actions ..................................................................................................384 CLEAR-Flow Rule Examples .....................................................................................................389 Count Expression Example .................................................................................................389

ExtremeWare XOS 11.3 Concepts Guide

11

Contents Delta Expression Example ..................................................................................................389 Ratio Expression Example ..................................................................................................390 Delta-Ratio Expression Example..........................................................................................392

Part 2: Using Switching and Routing Protocols


Chapter 19: Ethernet Automatic Protection Switching.................................................................... 395
Licensing ...............................................................................................................................395 Overview of the EAPS Protocol .................................................................................................395 Fast Convergence ..............................................................................................................397 Fault Detection and Recovery ...................................................................................................397 Link Down Message Sent by a Transit Node .........................................................................398 Ring Port Down Event Sent by Hardware Layer .....................................................................398 Polling .............................................................................................................................399 Restoration Operations.......................................................................................................399 Multiple EAPS Domains...........................................................................................................400 EAPS Data VLAN Spanning Two Rings Connected by One Switch...........................................400 Multiple EAPS Domains per RingSpatial Reuse.................................................................401 Multiple EAPS Rings Sharing a Common Link ......................................................................402 Configuring EAPS on a Switch ..................................................................................................403 Creating and Deleting an EAPS Domain...............................................................................404 Defining the EAPS Mode of the Switch................................................................................404 Configuring EAPS Polling Timers ........................................................................................405 Configuring the Primary and Secondary Ports .......................................................................406 Configuring the EAPS Control VLAN ....................................................................................406 Configuring the EAPS Protected VLANs ...............................................................................407 Enabling and Disabling Fast Convergence ............................................................................407 Enabling and Disabling an EAPS Domain.............................................................................407 Enabling and Disabling EAPS on the Switch ........................................................................407 Unconfiguring an EAPS Ring Port .......................................................................................408 Displaying EAPS Status Information....................................................................................408 Configuring EAPS Shared Ports ................................................................................................411 Steady State .....................................................................................................................412 Common Link Failures .......................................................................................................412 Flushing the FDBs.............................................................................................................414 Creating and Deleting a Shared Port....................................................................................414 Defining the Mode of the Shared Port..................................................................................414 Configuring the Link ID of the Shared Port...........................................................................414 Configuring the Shared Port Segment Timer.........................................................................415 Unconfiguring an EAPS Shared Port....................................................................................415 Displaying EAPS Shared-Port Status Information..................................................................415 EAPS Shared Port Configuration Rules ......................................................................................418 EAPS Shared Port Configuration Examples ................................................................................419 Basic Configuration ...........................................................................................................419 Basic Core Configuration....................................................................................................419 Right Angle Configuration ..................................................................................................420 Combined Basic Core and Right Angle Configuration ............................................................420 Large Core and Access Rings Configuration..........................................................................421 Advanced Configuration .....................................................................................................422

12

ExtremeWare XOS 11.3 Concepts Guide

Contents

Chapter 20: Spanning Tree Protocol............................................................................................. 423


Overview of the Spanning Tree Protocol.....................................................................................423 Spanning Tree Domains ...........................................................................................................423 Member VLANs .................................................................................................................424 STPD Modes.....................................................................................................................425 Encapsulation Modes.........................................................................................................425 STP States .......................................................................................................................426 Binding Ports....................................................................................................................427 Rapid Root Failover ...........................................................................................................429 STP and Hitless FailoverModular Switches Only ................................................................429 STP Configurations..................................................................................................................430 Basic STP Configuration ....................................................................................................430 Multiple STPDs on a Port ...................................................................................................433 VLAN Spanning Multiple STPDs .........................................................................................433 EMISTP Deployment Constraints ........................................................................................434 Per VLAN Spanning Tree..........................................................................................................436 STPD VLAN Mapping.........................................................................................................436 Native VLAN .....................................................................................................................436 Rapid Spanning Tree Protocol ..................................................................................................436 RSTP Concepts .................................................................................................................437 RSTP Operation ................................................................................................................439 STP Rules and Restrictions ......................................................................................................447 Configuring STP on the Switch .................................................................................................447 STP Configuration Examples ....................................................................................................448 Basic 802.1D Configuration Example..................................................................................448 EMISTP Configuration Example ..........................................................................................449 RSTP 802.1w Configuration Example..................................................................................450 Displaying STP Settings...........................................................................................................452

Chapter 21: Extreme Standby Router Protocol ............................................................................... 455


Overview of ESRP ...................................................................................................................455 ESRP Modes of Operation ..................................................................................................456 ESRP and ELRP................................................................................................................456 Reasons to Use ESRP ........................................................................................................456 ESRP Concepts.......................................................................................................................456 ESRP-Aware Switches .......................................................................................................458 Standard and Extended ESRP ............................................................................................459 ESRP Domains .................................................................................................................460 Linking ESRP Switches......................................................................................................461 ESRP and Hitless FailoverModular Switches Only..............................................................461 Determining the ESRP Master ..................................................................................................462 Master Switch Behavior .....................................................................................................463 Pre-Master Switch Behavior................................................................................................463 Slave Switch Behavior .......................................................................................................463 Neutral Switch Behavior ....................................................................................................463 Electing the Master Switch.................................................................................................463 ESRP Failover Time...........................................................................................................464 ESRP Election Algorithms ..................................................................................................465 Configuring an ESRP Domain on a Switch .................................................................................466 Creating and Deleting an ESRP Domain...............................................................................467

ExtremeWare XOS 11.3 Concepts Guide

13

Contents Configuring the ESRP Domain ID........................................................................................468 Adding VLANs to an ESRP Domain .....................................................................................468 Enabling and Disabling an ESRP Domain ............................................................................469 Advanced ESRP Features.........................................................................................................469 ESRP Tracking..................................................................................................................469 ESRP Port Restart .............................................................................................................473 ESRP Host Attach .............................................................................................................473 ESRP Port Weight and Dont Count .....................................................................................474 ESRP Groups ....................................................................................................................475 Displaying ESRP Information ...................................................................................................476 Using ELRP with ESRP............................................................................................................476 Using ELRP with ESRP to Recover Loops ............................................................................477 Configuring ELRP..............................................................................................................477 Displaying ELRP Information..............................................................................................478 ESRP Examples ......................................................................................................................479 Single Domain Using Layer 2 and Layer 3 Redundancy.........................................................479 Multiple Domains Using Layer 2 and Layer 3 Redundancy ....................................................482 ESRP Cautions .......................................................................................................................484 Configuring ESRP and IP Multinetting.................................................................................484 ESRP and STP..................................................................................................................484 ESRP and VRRP ...............................................................................................................484 ESRP Groups and Host Attach............................................................................................484 Port Configurations and ESRP ............................................................................................484

Chapter 22: Virtual Router Redundancy Protocol........................................................................... 485


Overview ................................................................................................................................485 Determining the VRRP Master ..................................................................................................485 VRRP Tracking..................................................................................................................486 Electing the Master Router.................................................................................................488 Additional VRRP Highlights......................................................................................................488 VRRP Operation ......................................................................................................................489 Simple VRRP Network Configuration ...................................................................................489 Fully Redundant VRRP Network..........................................................................................490 VRRP Configuration Parameters................................................................................................491 VRRP Examples ......................................................................................................................492 Configuring the Simple VRRP Network ................................................................................492 Configuring the Fully Redundant VRRP Network...................................................................493 VRRP Cautions .......................................................................................................................494 Assigning Multiple Virtual IP Addresses...............................................................................494 VRRP and ESRP ...............................................................................................................494

Chapter 23: IPv4 Unicast Routing................................................................................................. 495


Overview of IPv4 Unicast Routing .............................................................................................495 Router Interfaces ..............................................................................................................496 Populating the Routing Table .............................................................................................496 Proxy ARP ..............................................................................................................................499 ARP-Incapable Devices ......................................................................................................499 Proxy ARP Between Subnets ..............................................................................................500 Configuring IPv4 Unicast Routing .............................................................................................500

14

ExtremeWare XOS 11.3 Concepts Guide

Contents Verifying the IPv4 Unicast Routing Configuration .......................................................................501 Routing Configuration Example.................................................................................................501 IPv4 Multinetting ....................................................................................................................503 Multinetting Topology ........................................................................................................503 How Multinetting Affects Other Features .............................................................................504 Configuring IPv4 Multinetting.............................................................................................508 IP Multinetting Examples ...................................................................................................509 Configuring DHCP/BOOTP Relay ...............................................................................................509 Configuring the DHCP Relay Agent Option (Option 82) .........................................................510 Verifying the DHCP/BOOTP Relay Configuration ...................................................................510 UDP Forwarding......................................................................................................................511 Configuring UDP Forwarding ..............................................................................................511 UDP Echo Server ..............................................................................................................513

Chapter 24: IPv6 Unicast Routing................................................................................................. 515


Overview of IPv6 Unicast Routing .............................................................................................515 Router Interfaces ..............................................................................................................516 Specifying IPv6 Addresses .................................................................................................516 Neighbor Discovery Protocol ...............................................................................................518 Populating the Routing Table .............................................................................................519 Configuring IP Unicast Routing ................................................................................................522 Verifying the IP Unicast Routing Configuration .....................................................................522 Routing Configuration Example.................................................................................................522 Tunnel Configuration Examples ................................................................................................524 6in4 Tunnel Configuration Example ....................................................................................525 6to4 Tunnel Configuration Example ....................................................................................527

Chapter 25: RIP........................................................................................................................... 531


Overview ................................................................................................................................531 RIP Versus OSPF ..............................................................................................................531 Advantages of RIP and OSPF..............................................................................................532 Overview of RIP ......................................................................................................................532 Routing Table ...................................................................................................................532 Split Horizon ....................................................................................................................533 Poison Reverse .................................................................................................................533 Triggered Updates .............................................................................................................533 Route Advertisement of VLANs ...........................................................................................533 RIP Version 1 Versus RIP Version 2 ....................................................................................533 Route Redistribution ...............................................................................................................533 Configuring Route Redistribution ........................................................................................534 RIP Configuration Example ......................................................................................................535

Chapter 26: RIPng ....................................................................................................................... 539


Overview ................................................................................................................................539 RIPng Versus OSPFv3........................................................................................................539 Advantages of RIPng and OSPFv3.......................................................................................540 Overview of RIPng ...................................................................................................................540 Routing Table ...................................................................................................................540 Split Horizon ....................................................................................................................541

ExtremeWare XOS 11.3 Concepts Guide

15

Contents Poison Reverse .................................................................................................................541 Triggered Updates .............................................................................................................541 Route Advertisement of VLANs ...........................................................................................541 Route Redistribution ...............................................................................................................541 Configuring Route Redistribution ........................................................................................541 RIPng Configuration Example ...................................................................................................542

Chapter 27: OSPF ........................................................................................................................ 543


Overview of OSPF....................................................................................................................543 Licensing .........................................................................................................................543 OSPF Edge Mode ..............................................................................................................544 Link State Database ..........................................................................................................544 Graceful OSPF Restart .......................................................................................................545 Areas ...............................................................................................................................546 Point-to-Point Support .......................................................................................................549 Route Redistribution ...............................................................................................................550 Configuring Route Redistribution ........................................................................................550 OSPF Timers and Authentication ........................................................................................551 Configuring OSPF....................................................................................................................551 Configuring OSPF Wait Interval...........................................................................................551 OSPF Wait Interval Parameters ...........................................................................................552 OSPF Configuration Example....................................................................................................553 Configuration for ABR1......................................................................................................554 Configuration for IR1 .........................................................................................................554 Displaying OSPF Settings.........................................................................................................555

Chapter 28: OSPFv3 .................................................................................................................... 557


Overview of OSPFv3 ................................................................................................................557 Licensing .........................................................................................................................557 Link State Database ..........................................................................................................557 Areas ...............................................................................................................................558 Link-Type Support.............................................................................................................560 Route Redistribution ...............................................................................................................561 Configuring Route Redistribution ........................................................................................562 OSPFv3 Timers .................................................................................................................563 OSPFv3 Configuration Example ................................................................................................563 Configuration for Router 1..................................................................................................564 Configuration for Router 2..................................................................................................565 Configuration for Router 3..................................................................................................565

Chapter 29: Border Gateway Protocol ........................................................................................... 567


Licensing ...............................................................................................................................567 Overview ................................................................................................................................568 BGP Attributes........................................................................................................................568 BGP Communities ...................................................................................................................568 BGP Features .........................................................................................................................569 Route Reflectors ...............................................................................................................569 Route Confederations ........................................................................................................571 Route Aggregation .............................................................................................................574

16

ExtremeWare XOS 11.3 Concepts Guide

Contents Using the Loopback Interface .............................................................................................574 BGP Peer Groups ..............................................................................................................574 BGP Route Flap Dampening ...............................................................................................575 BGP Route Selection .........................................................................................................577 Stripping Out Private AS Numbers from Route Updates ........................................................577 Route Redistribution .........................................................................................................577 BGP Static Network...........................................................................................................578

Chapter 30: IP Multicast Routing.................................................................................................. 579


Overview ................................................................................................................................579 PIM Overview....................................................................................................................579 IGMP Overview .................................................................................................................581 Configuring IP Multicast Routing ..............................................................................................583 Configuration Examples ...........................................................................................................583 PIM-DM Configuration Example ..........................................................................................584 PIM-SM Configuration Example ..........................................................................................585

Chapter 31: IPv6 Multicast Routing .............................................................................................. 587


Overview ................................................................................................................................587 MLD Overview...................................................................................................................587

Part 3: Appendixes
Appendix A: Software Upgrade and Boot Options........................................................................... 591
Downloading a New Image .......................................................................................................591 Image Filename Prefixes ....................................................................................................591 Understanding the Image Version String ..............................................................................592 Software Signatures...........................................................................................................592 Selecting a Primary or a Secondary Image ...........................................................................593 Installing a Core Image ......................................................................................................593 Installing a Modular Software Package ................................................................................594 Rebooting the Switch ........................................................................................................596 Rebooting the Management ModuleModular Switches Only ................................................597 Understanding Hitless UpgradeBlackDiamond 10K Switch Only ...............................................597 Performing a Hitless Upgrade .............................................................................................598 Hitless Upgrade Examples..................................................................................................600 Saving Configuration Changes ..................................................................................................601 Viewing a Configuration .....................................................................................................602 Returning to Factory Defaults .............................................................................................602 Using TFTP to Upload the Configuration....................................................................................603 Using TFTP to Download the Configuration ................................................................................603 Synchronizing MSMsModular Switches Only ...........................................................................604 Additional Behavior on the BlackDiamond 8800 Family of Switches Only ...............................604 Automatic Synchronization of Configuration Files .................................................................605 Accessing the Bootloader .........................................................................................................605 Upgrading the BootROMBlackDiamond 10K Switch Only.........................................................606 Upgrading the BootROMSummit X450 Switch Only.................................................................606 Accessing the Bootstrap CLI on the Summit X450................................................................607 Upgrading the FirmwareBlackDiamond 8800 Family of Switches Only ......................................607

ExtremeWare XOS 11.3 Concepts Guide

17

Contents

Appendix B: Troubleshooting ....................................................................................................... 609


Troubleshooting Checklists.......................................................................................................609 Layer 1 ............................................................................................................................609 Layer 2 ............................................................................................................................610 Layer 3 ............................................................................................................................610 LEDs......................................................................................................................................612 Using the Command Line Interface ...........................................................................................614 General Tips and Recommendations ...................................................................................614 MSM PromptModular Switches Only ................................................................................616 Command Prompt .............................................................................................................616 Port Configuration .............................................................................................................617 VLANs..............................................................................................................................618 STP .................................................................................................................................618 ESRP ...............................................................................................................................619 VRRP ...............................................................................................................................620 Using Standalone ELRP to Perform Loop Tests ..........................................................................620 About Standalone ELRP.....................................................................................................621 Configuring Standalone ELRP.............................................................................................621 Displaying Standalone ELRP Information.............................................................................622 Using the Rescue Software ImageModular Switches Only.........................................................623 Obtaining the Rescue Image from a TFTP Server ..................................................................623 Obtaining the Rescue Image from an External Compact Flash Memory Card BlackDiamond 8800 Family of Switches Only ......................................................................624 Debug Mode ...........................................................................................................................626 Saving Debug Information to the Memory Card...........................................................................626 Enabling the Switch to Send Debug Information...................................................................627 Copying Debug Information ................................................................................................627 Managing Files on the External Memory CardModular Switches Only ...................................627 TOP Command........................................................................................................................629 TFTP Server Requirements.......................................................................................................629 System Health CheckModular Switches Only ..........................................................................629 Overview of the System Health Checker ...............................................................................629 Enabling and Disabling Backplane Diagnostic Packets on the Switch .....................................630 Configuring Backplane Diagnostic Packets on the Switch ......................................................631 System Odometer....................................................................................................................631 Monitored Components ......................................................................................................631 Recorded Statistics ...........................................................................................................631 Temperature Operating Range ..................................................................................................632 Corrupted BootROM on the BlackDiamond 8800 Family of Switches............................................633 Inserting Powered Devices in the PoE ModuleBlackDiamond 8800 Family of Switches Only........633 Untagged Frames on the 10 Gbps ModuleBlackDiamond 10K Switch Only................................633 Running MSM Diagnostics from the BootloaderBlackDiamond 10K Switch Only ........................633 Contacting Extreme Networks Technical Support........................................................................634

Appendix C: CNA Agent................................................................................................................ 635


Overview ................................................................................................................................635 RedundancyBlackDiamond 10K Switch and BlackDiamond 8800 Family of Switches Only ...636 Downloading the CNA Agent Software Module............................................................................636 Running the Tests ...................................................................................................................636

18

ExtremeWare XOS 11.3 Concepts Guide

Contents Configuring the CNA Agent ......................................................................................................637 Enabling the CNA Agent ....................................................................................................637 Connecting to the CNA Server ............................................................................................637 Configuring the Interface ...................................................................................................638 Clearing the Counters ........................................................................................................638 Displaying CNA Agent Information ......................................................................................638 Troubleshooting ................................................................................................................639

Appendix D: Supported Protocols, MIBs, and Standards................................................................. 641 Glossary ..................................................................................................................................... 645 Index of Commands ..................................................................................................................... 671 Index .......................................................................................................................................... 677

ExtremeWare XOS 11.3 Concepts Guide

19

Contents

20

ExtremeWare XOS 11.3 Concepts Guide

Preface
This preface provides an overview of this guide, describes guide conventions, and lists other publications that might be useful.

Introduction
This guide provides the required information to configure ExtremeWare XOS software version 11.3 running on switches from Extreme Networks. The guide is intended for use by network administrators who are responsible for installing and setting up network equipment. It assumes a basic working knowledge of:

Local area networks (LANs) Ethernet concepts Ethernet switching and bridging concepts Routing concepts Internet Protocol (IP) concepts Routing Information Protocol (RIP) and Open Shortest Path First (OSPF) Border Gateway Protocol (BGP-4) concepts IP Multicast concepts Protocol Independent Multicast (PIM) concepts Simple Network Management Protocol (SNMP) NOTE

If the information in the release notes shipped with your switch differs from the information in this guide, follow the release notes.

Terminology
When features, functionality, or operation is specific to a switch family, the family name is used. Explanations about features and operations that are the same across all product families simply refer to the product as the switch.

ExtremeWare XOS 11.3 Concepts Guide

21

Preface

Conventions
This section discusses conventions used in the documentation. The following topics are discussed:

Platform-Dependent Conventions on page 22 Text Conventions on page 22

Platform-Dependent Conventions
Unless otherwise noted, all information applies to all platforms supported by ExtremeWare XOS software, which are the following:

BlackDiamond 10800 family of switches BlackDiamond 8810 switch (formerly known as Aspen) Summit X450 switch BlackDiamond 8806 switch

When a feature or feature implementation applies to specific platforms, the specific platform is noted in the heading for the section describing that implementation. Finally, minor differences in platform implementations are called in a note, as shown below:

NOTE
This is a note.

Text Conventions
Table 1 and Table 2 list conventions that are used throughout this guide.

Table 1: Notice icons


Icon Notice Type Note Alerts you to... Important features or instructions.

Caution

Risk of personal injury, system damage, or loss of data.

Warning

Risk of severe personal injury.

22

ExtremeWare XOS 11.3 Concepts Guide

Related Publications

Table 2: Text conventions


Convention Screen displays The words enter and type [Key] names Description This typeface indicates command syntax, or represents information as it appears on the screen. When you see the word enter in this guide, you must type something, and then press the Return or Enter key. Do not press the Return or Enter key when an instruction simply says type. Key names are written with brackets, such as [Return] or [Esc]. If you must press two or more keys simultaneously, the key names are linked with a plus sign (+). Example: Press [Ctrl]+[Alt]+[Del]. Words in italicized type Italics emphasize a point or denote new terms at the place where they are defined in the text. (Italics are also used when referring to publication titles.)

Related Publications
The publications related to this one are:

ExtremeWare XOS release notes ExtremeWare XOS Command Reference Guide Extreme Networks Consolidated XOS Hardware Installation Guide

Documentation for Extreme Networks products is available on the World Wide Web at the following location: http://www.extremenetworks.com/

Using ExtremeWare XOS Publications Online


You can access ExtremeWare XOS publications by downloading them from the Extreme Networks World Wide Web location or from your ExtremeWare product CD. Publications are provided in Adobe Portable Document Format (PDF). Displaying or printing PDF files requires that your computer be equipped with Adobe Reader software, which is available free of charge from Adobe Systems Incorporated. The user guide PDF file provides links that connect you directly to relevant command information in the command reference guide PDF file. This quick-referencing capability enables you to easily find detailed information in the command reference guide for any command mentioned in the user guide. To ensure that the quick-referencing feature functions properly, follow these steps: 1 Download both the user guide PDF file and the command reference guide PDF file to the same destination directory on your computer. 2 You may open one or both PDF files and to enable cross-referenced linking between the user guide and command reference guide; however, it is recommended that for ease of use, you keep both files open concurrently on your computer desktop.

ExtremeWare XOS 11.3 Concepts Guide

23

Preface

NOTE
If you activate a cross-referencing link from the concepts guide PDF file to the command reference PDF file when the command reference PDF file is closed (that is, not currently open on your computer desktop), the system will close the user guide PDF file and open the command reference PDF file. To keep both PDF files open when you activate a cross-reference link, open both PDF files before using the link.

24

ExtremeWare XOS 11.3 Concepts Guide

Using ExtremeWare XOS

ExtremeWare XOS Overview

This chapter covers the following topics:


Platforms and Required Software Versions on page 27 Summary of Features on page 27 Software Licensing on page 33 Software Factory Defaults on page 36

This chapter provides an overview of the ExtremeWare XOS version 11.3 software.

Platforms and Required Software Versions


ExtremeWare XOS is the full-featured software operating system that is designed to run on the Extreme Networks devices. ExtremeWare XOS supports the following platforms:

BlackDiamond 10800 family of switchesExtremeWare XOS 10.1 and higher BlackDiamond 8810 switch (formerly known as Aspen)ExtremeWare XOS 11.1 and higher Summit X450 switchExtremeWare XOS 11.2 and higher BlackDiamond 8806 switchExtremeWare XOS 11.3.1. and higher NOTE

See Platform-Dependent Conventions in the Preface for information on how to determine platform-specific implementations or features.

Summary of Features
The features of ExtremeWare XOS include:

Virtual local area networks (VLANs) including support for IEEE 802.1Q and IEEE 802.1p Spanning Tree Protocol (STP) (IEEE 802.1D) with multiple STP domains Policy-Based Quality of Service (PB-QoS) Wire-speed Internet Protocol (IP) routing IP multinetting DHCP/BOOTP Relay Extreme Standby Router Protocol (ESRP) Ethernet Automatic Protection Switching (EAPS) Extreme Loop Recovery Protocol (ELRP) Virtual Router Redundancy Protocol (VRRP)

ExtremeWare XOS 11.3 Concepts Guide

27

ExtremeWare XOS Overview


Routing Information Protocol (RIP) version 1 and RIP version 2 RIPng Open Shortest Path First (OSPF) Version 2 Routing Protocol Open Shortest Path First (OSPF) Version 3 Routing Protocol Border Gateway Protocol (BGP) version 4 DiffServ support Access-policy support for routing protocols Access list support for packet filtering IGMP snooping to control IP multicast traffic Protocol Independent Multicast-Dense Mode (PIM-DM) Protocol Independent Multicast-Sparse Mode (PIM-SM) Load sharing on multiple ports, across all blades RADIUS client and per command authentication support TACACS+ support Console command line interface (CLI) connection Telnet CLI connection Secure Shell (SSH2) connection Simple Network Management Protocol (SNMP) support Remote Monitoring (RMON) Traffic mirroring Network Login support CLEAR-Flow Link Layer Discovery Protocol (LLDP) IPv6 Link Access Control Protocol (LACP NetLogin NOTE

For more information on Extreme Networks switch components, see the Extreme Networks Consolidated XOS Hardware Installation Guide.

Feature Highlights of ExtremeWare XOS 11.3


Virtual Routers
NOTE
Although the BlackDiamond 8800 family of switches and the Summit X450 switch support the three system virtual routers (VR-Default, VR-Mgmt, VR-Control), the BlackDiamond 10K switch additionally supports user-created virtual routers.

28

ExtremeWare XOS 11.3 Concepts Guide

Summary of Features ExtremeWare XOS supports virtual routers. This capability allows a single physical switch to be split into multiple virtual routers. This feature separates the traffic forwarded by a virtual router from the traffic on a different virtual router. Each virtual router maintains a separate logical forwarding table, which allows the virtual routers to have overlapping address spaces. Because each virtual router maintains its own separate routing information, packets arriving at a port on one virtual router can never be switched to the ports on another. In this release of ExtremeWare XOS, the management port belongs to one virtual router and all other ports belong to other virtual routers. With software release 11.2, ports can belong to multiple virtual routers. With multiple virtual routers contained on a single physical switch, some commands in ExtremeWare XOS now require you to specify to which virtual router the command applies. For example, when you use the ping command, you must specify from which virtual router the ping packets are generated. Many commands that deal with switch management use the management virtual router by default. See the ExtremeWare XOS Command Reference Guide for information on the defaults for individual commands.

NOTE
The term virtual router is also used with VRRP. VRRP uses the term to refer to a single virtual router that spans more than one physical router and allows multiple switches to provide redundant routing services to users. For more information about VRRP, see Chapter 22.

For more information on virtual routers, see Chapter 10.

Software Modules
With software version 11.0, ExtremeWare XOS introduces the ability for the user to download a discrete software module (or feature pack) that contains complete functionality for a specified feature. The user no longer must download the entire image in order to obtain these specific modules. Secure Shell (SSH) is the software module available with version 11.0, and the Converged Network Analysis (CNA) test plug is available with 11.2. (Refer to Appendix C for information on the CNA test plug software, which you use only if you are running an Avaya voice over IP (VoIP) solution.)

SSH
To access the switch using the Secure Shell (SSH), you must download, install, and enable the SSH software module. Once installed, you use the SSH to access the switch. You obtain the SSH software module through your Extreme Networks support account on the website, once you provide the required information. With ExtremeWare XOS version 11.2, Secure Socket Layer (SSL) software is bundled with the SSH software module. For more information on SSH and SSL, see Chapter 16.

EAPS
With software version 11.0, the switch supports Ethernet Automatic Protection Switching (EAPS). This Extreme Networks proprietary protocol provides fast protection switching to Layer 2 devices connected in a ring topology, such as large campuses. EAPS provides protection to switching similar to STP, but

ExtremeWare XOS 11.3 Concepts Guide

29

ExtremeWare XOS Overview the convergence is much faster using EAPS. This fast convergence occurs regardless of the number of switches in the ring. ExtremeWare XOS software version 11.1 introduces support for multiple EAPS rings. To use this feature, you must have Core license. (Refer to Software Licensing for more information on the Core license.) For more information on EAPS, see Chapter 19.

Quality of Service
ExtremeWare XOS has Policy-Based Quality of Service (QoS) features that enable you to specify service levels for different traffic groups. By default, all traffic is assigned the low QoS policy profile. If needed, you can customize other QoS policies and apply these policies to different traffic types so that the traffic types have different guaranteed priority. With software version 11.0 on the BlackDiamond 10K switch, you can set parameters for ingress traffic, called bi-directional rate shaping; the BlackDiamond 8800 family of switches and the Summit X450 switch do not support bi-directional rate-shaping. For more information on Quality of Service, see Chapter 15.

sFlow
sFlow is a technology for monitoring traffic in data networks containing switches and routers. The technology relies on statistical sampling of packets from high-speed networks, plus periodic gathering of the statistics. A UDP datagram format is defined to send the information to an external entity for analysis. sFlow consists of a Management Information Base (MIB) and a specification of the packet format for forwarding information to a remote agent. Details of sFlow specifications can be found in RFC 3176, and specifications and more information can be found at the following website: http://www.sflow.org The ExtremeWare XOS implementation is based on sFlow version 5, an improvement from that specified in RFC3176. For information on sFlow, see Chapter 8.

ESRP
With software version 11.0, you can use the Extreme Standby Routing Protocol (ESRP). ESRP is an Extreme Networks proprietary protocol that allows multiple switches to provide redundant routing services to users. ESRP also provides Layer 2 redundancy; the Layer 3 and Layer 2 redundancy can be used separately or together. Using ESRP allows you to simplify your network, and it works very well in meshed networks where Layer 2 loop protection and Layer 3 redundancy are both required. For more information on ESRP, see Chapter 21.

30

ExtremeWare XOS 11.3 Concepts Guide

Summary of Features

IP Multinetting
Software version 11.0 of ExtremeWare XOS introduces IP multinetting, which allows you to overlap multiple subnets onto the same physical segment. IP multinetting is designed for use in legacy networks, as a transitional tactic. For more information on IP multinetting, see Chapter 23.

RMON
With software version 11.1, ExtremeWare XOS introduces Remote Monitoring (RMON), which supports RFC 1757 and RFC 2021. RMON provides a method of monitoring the network by collecting Ethernet port statistics and to set systemwide alarm variables. For more information on RMON, see Chapter 8.

ELRP
ExtremeWare XOS 11.1 introduces support for the Extreme Loop Recovery Protocol (ELRP) ELRP allows you to prevent, detect, and recover from Layer 2 loops in the network. Once a loop is detected through ELRP, different recovery actions can be taken such as blocking certain ports to prevent looping or logging a message to the system log. The action taken is largely dependent on the protocol using ELRP to detect loops in the network. For more information on using standalone ELRP, see Appendix B. For more information on using ELRP in conjunction with ESRP, see Chapter 21.

Network Login
Network Login is a method of authenticating users as hosts are added to a network. As a new host is added to the network, its port connection is in an unauthenticated state, denying any access to the network. During authentication, the user supplies a password to the switch using the host. If authenticated, the port connection is authenticated, and traffic flows to and from the host and the network. ExtremeWare XOS version 11.3 introduces the following network login enhancements: hitless failover support, local database authentication, secure MAC, and netlogin MAC-based VLANs:

Hitless failoverModular switches with network login configured and enabled support hitless failover by relaying current client authentication information from the primary MSM to the backup MSM. If failover occurs during the authentication or re-authentication of a client, the client must repeat the authentication process. Local database authenticationYou can explicitly configure and use the local database for authentication instead of using a RADIUS server. In ExtremeWare XOS 11.2, the local database was available only if the RADIUS servers became unavailable. Secure MACYou can configure ports on the switch to accept and authenticate a client with a specific MAC address. If you associate a MAC address with one or more ports, only authentication requests for that MAC address received on the port(s) are sent to the configured RADIUS server or local database; the port(s) block all other authentication requests. Netlogin MAC-based VLANsThe BlackDiamond 8800 family of switches and the Summit X450 switch support netlogin MAC-based VLANs. Netlogin MAC-based VLANs allow a port assigned to

ExtremeWare XOS 11.3 Concepts Guide

31

ExtremeWare XOS Overview a VLAN to operate in a MAC-based fashion. This means that each individual untagged supplicant, identified by its MAC address, can be in different VLANs. For more information on network login, see Chapter 17.

CLEAR-Flow
CLEAR-Flow is a broad framework for implementing security, monitoring, and anomaly detection in ExtremeWare XOS software. Instead of simply looking at the source and destination of traffic, CLEARFlow allows you to specify certain types of traffic that require more attention. Once certain criteria for this traffic are met, the switch can either take an immediate, predetermined action; or it can send a copy of the traffic to another device for analysis.

IPv6
With version 11.2, ExtremeWare XOS software supports IPv6. IPv6 is a more robust IP addressing scheme and allows for next-generation routing.

NOTE
IP refers to IPv4; IPv6 is always referred to as IPv6.

For more information on IPv6, see Chapter 24.

LLDP
ExtremeWare XOS version 11.2 introduces support for the Link Layer Discovery Protocol (LLDP). LLDP is a Layer 2 protocol (IEEE standard 802.1ab) that is used to determine the capabilities of devices such as repeaters, bridges, access points, routers, and wireless stations. ExtremeWare XOS version 11.2 LLDP support enables devices to advertise their capabilities and media-specific configuration information and to learn the same information from the devices connected to it. LLDP provides a standard method of discovering and representing the physical network connections of a given network management domain. LLDP works together with Extreme Discovery Protocol (EDP). The LLDP neighbor discovery protocol allows you to discover and maintain accurate network topologies in a multivendor environment. For complete information on LLDP, see Chapter 6.

LACP
Beginning with ExtremeWare XOS version 11.3, you can run the Link Aggregation Control Protocol (LACP) on Extreme Networks devices. LACP enables dynamic load sharing and hot standby for link aggregation links, in accordance with the IEEE 802.3ad standard. All third-party devices supporting LACP run with Extreme Networks devices. The addition of LACP provides the following enhancements to static load sharing, or link aggregation:

Automatic configuration

32

ExtremeWare XOS 11.3 Concepts Guide

Software Licensing

Rapid configuration and reconfiguration Deterministic behavior Low risk of duplication or misordering

For complete information on load sharing and LACP, see Chapter 5.

Software Licensing
Some Extreme Networks products have capabilities that are enabled by using a software license key. Keys are typically unique to the switch and are not transferable. Keys are stored in NVRAM on the chassis and, once enabled, persist through reboots, software upgrades, power outages, and reconfigurations. As all switches ship with Advanced Edge capabilities, two level of software licensing apply to ExtremeWare XOS 11.3: the Core and the Advanced Core license (refer to Table 3). Additionally, the U.S. government requires a security license to enable certain features.

Table 3: Licensing requirements for ExtremeWare XOS version 11.3


License level Advanced Edge Core Advanced Core BlackDiamond 10K switch Ships (as part of Core license) Ships MSM 1N/A MSM1XLShips BlackDiamond 8800 family of switches Ships Requires license N/A Summit X450 switch Ships Requires license N/A

NOTE
With ExtremeWare XOS software version 11.2, BGP functionality moved from the Advanced Core license level to the Core license. You have BGP functionality with a Core license.

When you are working with modular switches, the license belongs with the switch chassis, not with the particular MSM module. The licensing levels required for each feature, if any, are outlined in the discussion of each feature. If licensing is not mentioned, the full functionality of that feature is available on every switch.

License Levels
This section discusses the licensing capabilities of the various switches.

Upgrading on the BlackDiamond 8800 Family of Switches and Summit X450 Switch Only
The BlackDiamond 8800 family of switches and the Summit X450 switch ship with an Advanced Edge license. With ExtremeWare XOS 11.2, you can obtain the Core license for these switches. The Core

ExtremeWare XOS 11.3 Concepts Guide

33

ExtremeWare XOS Overview license provides additional functionality for some features, as well as Border Gateway Protocol (BGP) functionality, on the switches. The Advanced Core license is not available for the BlackDiamond 8800 family of switches or the Summit X450 switch. Once you obtain a license, you cannot downgrade licenses. The license key contains all the necessary information on the license level.

NOTE
Refer to the specific chapter of the ExtremeWare XOS Concepts Guide to determine if the Core license is required for some functionality. If not noted, all functionality is available, and license is not required.

If you attempt to execute a command and you do not either have the required license or have reached the limits defined by the current license level, the system returns one of the following messages:
Error: This command cannot be executed at the current license level. Error: You have reached the maximum limit for this feature at this license level.

Upgrading on the BlackDiamond 10K Switch Only


The licensing levels on the BlackDiamond 10K switch depend on the MSM you have in your system:

The MSM 1 ships with a Core license; you cannot upgrade to an Advanced Core license. The MSM 1XL ships with an Advanced Core license. NOTE

Beginning with ExtremeWare XOS version 11.2, you can run BGP with a core license on the BlackDiamond 10K switch; that is both the MSM1 and the MSM1XL now run BGP.

If you attempt to execute a command and you do not either have the required license or have reached the limits defined by the current license level, the system returns one of the following messages:
Error: This command cannot be executed at the current license level. Error: You have reached the maximum limit for this feature at this license level.

Licensed Features in ExtremeWare XOS Version 11.2 or later


The following features require a Core license when you are using ExtremeWare XOS version 11.2 or later:

EAPS full (multiple rings with multiple interconnecting points) PIM DM full PIM SM full OSPFv2 full (not limited to 2 adjacencies) OSPFv3 full (not limited to 2 adjacencies) BGP4

34

ExtremeWare XOS 11.3 Concepts Guide

Software Licensing

Obtaining a License Voucher


You can order the desired functionality from the factory, using the appropriate model of the desired product. If you order licensing from the factory, the license arrives in a separate package from the switch. After the license key is installed, it should not be necessary to enter the information again. However, Extreme Networks recommends keeping the certificate for your records. You can obtain a regular license; you cannot downgrade licenses. The software key contains all the necessary information on the license level. You can upgrade the license of an existing product by purchasing a license voucher from Extreme Networks. Please contact your supplier to purchase a voucher. The voucher contains information and instructions on obtaining a license key for the switch using the Extreme Networks Support website at:
http://www.extremenetworks.com/support/techsupport.asp

or by phoning Extreme Networks Technical Support at:


(800) 998-2408 (408) 579-2826

Enabling and Verifying Licenses


To enable the license, use the following command:
enable license <key>

To verify the current license level as well as enabled feature packs (or installed software modules), use the following command:
show licenses

Security Licensing
Certain additional ExtremeWare XOS features, such as the use of SSH2 encryption, may be under United States export restriction control. Extreme Networks ships these security features in a disabled state. You can obtain information on enabling these features at no charge from Extreme Networks. The SSH2 feature is in a separate, loadable software module, which must be installed on the Extreme Networks switches.

Obtaining a Security License


To obtain information on enabling features that require export restriction, access the Extreme Networks Support website at: http://www.extremenetworks.com/go/security.htm Fill out a contact form to indicate compliance or noncompliance with the export restrictions. If you are in compliance, you will be given information that will allow you to enable security features. You need the following capabilities to ensure the process works:

ExtremeWare XOS 11.3 Concepts Guide

35

ExtremeWare XOS Overview


Email address Ability to use a Web browser to download a file WinZip format to uncompress a .zip file

Security Features Under License Control


ExtremeWare XOS software supports the SSH2 protocol, which allows the encryption of sessions between an SSH2 client and an Extreme Networks switch, as well as the Secure Copy Protocol (SCP). The encryption methods used are under export restriction control.

Software Factory Defaults


Table 4 shows factory defaults for global ExtremeWare XOS software version 11.3 features.

Table 4: ExtremeWare XOS version 11.3 global factory defaults


Item Serial or Telnet user account Telnet Port status SSH2 SNMP access SSL SNMP read community string SNMP write community string BOOTP/BOOTP Relay/BOOTP Client Jumbo frames EAPS EDP Port mirroring Load sharing ESRP QoS QoS802.1p replacement QoSDiffServ examination VMANexamining inner dot1p value Autonegotiation Default Setting admin with no password and user with no password Enabled Enabled Disabled (You must install a separate software module to run SSH.) Enabled Disabled (You must install a separate software module to run SSL SSH module.) public private Disabled Disabled; once enabled, the default size is 9216. Disabled Enabled Disabled Disabled Disabled All traffic is part of the default queue (QP1). Disabled Disabled Disabled 10 G modulesautonegotiation OFF, speed 10000 Mbps, fullduplex 1 G modulesautonegotiation ON Virtual LANs Two VLANs are predefined; the VLAN named default contains all ports and belongs to the Spanning Tree Protocol Domain (STPD) named s0. The VLAN mgmt exists only on switches that have an Ethernet management port and contains only that port. The switch uses the Ethernet management port for host operation only, not for switching or routing.

36

ExtremeWare XOS 11.3 Concepts Guide

Software Factory Defaults

Table 4: ExtremeWare XOS version 11.3 global factory defaults (Continued)


Item 802.1Q tagging Spanning Tree Protocol STPD port encapsulation mode Default Setting All packets are untagged on the default VLAN (default). Disabled for the switch; enabled for each port in the STPD. default STPD802.1D mode user-created STPDExtreme Multiple Instance Spanning Tree Protocol (EMISTP) Forwarding database aging period IPv4 Routing RIP OSPFv2 BGPv4 IPv6 Routing RIPng OSPFv3 Smart Redundancy System health check RADIUS authentication port value RADIUS accounting port value OSPF link type VRRP priority IGMP IGMP snooping PoE power to port PoE power per slot PoE port priority ELRP Net Login Egress flooding LLDP Autopolarity 300 seconds (5 minutes) Disabled Disabled Disabled Disabled Disabled Disabled Disabled Enabled Enabled 1812 1813 Auto 100 Enabled Enabled Enabled 50 W Low Disabled Disabled Enabled Disabled Enabled

NOTE
For default settings of individual ExtremeWare XOS features, see individual chapters in this guide.

ExtremeWare XOS 11.3 Concepts Guide

37

ExtremeWare XOS Overview

38

ExtremeWare XOS 11.3 Concepts Guide

Accessing the Switch

This chapter covers the following topics:


Understanding the Command Syntax on page 39 Port Numbering on page 42 Line-Editing Keys on page 43 Command History on page 44 Common Commands on page 44 Accessing the Switch the First Time on page 46 Configuring Management Access on page 47 Managing Passwords on page 50 Access to Both MSM Console PortsModular Switches Only on page 53 Domain Name Service Client Services on page 53 Checking Basic Connectivity on page 54 Displaying Switch Information on page 56

Understanding the Command Syntax


This section describes the steps to take when entering a command. Refer to the sections that follow for detailed information on using the command line interface (CLI). ExtremeWare XOS command syntax is described in detail in the ExtremeWare XOS Command Reference Guide. Some commands are also described in this user guide, in order to describe how to use the features of the ExtremeWare XOS software. However, only a subset of commands are described here, and in some cases only a subset of the options that a command supports. The ExtremeWare XOS Command Reference Guide should be considered the definitive source for information on ExtremeWare XOS commands. You may enter configuration commands at the # prompt. At the > prompt, you may enter only monitoring commands, not configuration commands. When you log in as administrator (which has read and write access), you see the # prompt. When you log in as user (which has only read access), you will see the > prompt. As you are booting up, you may see the > command prompt. When the bootup process is complete, the # prompt appears. When entering a command at the prompt, ensure that you have the appropriate privilege level. Most configuration commands require you to have the administrator privilege level. For more information on setting CLI privilege levels, see the ExtremeWare XOS Command Reference Guide. To use the CLI, follow these steps: 1 Enter the command name. If the command does not include a parameter or values, skip to step 3. If the command requires more information, continue to step 2.

ExtremeWare XOS 11.3 Concepts Guide

39

Accessing the Switch 2 If the command includes a parameter, enter the parameter name and values. The value part of the command specifies how you want the parameter to be set. Values include numerics, strings, or addresses, depending on the parameter. 3 After entering the complete command, press [Return]. NOTE
If an asterisk (*) appears in front of the command line prompt, it indicates that you have outstanding configuration changes that have not been saved. For more information on saving configuration changes, see Appendix A.

This section includes the following topics:


Syntax Helper on page 40 Command Shortcuts on page 41 Names on page 41 Symbols on page 41 Limits on page 42

Syntax Helper
The CLI has a built-in syntax helper. If you are unsure of the complete syntax for a particular command, enter as much of the command as possible and press [Tab] or [?]. The syntax helper provides a list of options for the remainder of the command and places the cursor at the end of the command you have entered so far, ready for the next option. If you enter an invalid command, the syntax helper notifies you of your error and indicates where the error is located. If the command is one where the next option is a named component (such as a VLAN, access profile, or route map), the syntax helper will also list any currently configured names that might be used as the next option. In situations where this list is very long, the syntax helper lists only one line of names, followed by an ellipses (...) to indicate that there are more names that can be displayed. The syntax helper also provides assistance if you have entered an incorrect command.

Abbreviated Syntax
Abbreviated syntax is the shortest unambiguous allowable abbreviation of a command or parameter. Typically, this is the first three letters of the command. If you do not enter enough letters to allow the switch to determine which command you mean, the syntax helper will provide a list of the options based on the portion of the command you have entered. NOTE
When using abbreviated syntax, you must enter enough characters to make the command unambiguous and distinguishable to the switch.

40

ExtremeWare XOS 11.3 Concepts Guide

Understanding the Command Syntax

Command Shortcuts
Components are typically named using the create command. When you enter a command to configure a named component, you do not need to use the keyword of the component. For example, to create a VLAN, enter a VLAN name:
create vlan engineering

After you have created the name for the VLAN, you can then eliminate the keyword vlan from all other commands that require the name to be entered. For example, instead of entering the modular switch command:
configure vlan engineering delete port 1:3,4:6

you could enter the following shortcut:


configure engineering delete port 1:3,4:6

Although it is helpful to have unique names for system components, this is not a requirement. If ExtremeWare XOS encounters any ambiguity in the components within your command, it generates a message requesting that you clarify the object you specified.

NOTE
If you use the same name across categories (for example, STPD and VLAN names), Extreme Networks recommends that you specify the identifying keyword as well as the actual name. If you do not use the keyword, the system may return an error message.

Names
All named components within a category of the switch configuration, such as VLAN, must have a unique name. Names can be re-used across categories, however. Names must begin with an alphabetical character and cannot contain any spaces. The maximum length for a name is 32 characters. Names may contain alphanumeric characters and underscores (_) and cannot be keywords, such as vlan, stp, and so on. NOTE
If you use the same name across categories (for example, STPD and VLAN names), Extreme Networks recommends that you specify the identifying keyword as well as the actual name. If you do not use the keyword, the system may return an error message.

Symbols
You may see a variety of symbols shown as part of the command syntax. These symbols explain how to enter the command, and you do not type them as part of the command itself. Table 5 summarizes command syntax symbols.

ExtremeWare XOS 11.3 Concepts Guide

41

Accessing the Switch

Table 5: Command syntax symbols


Symbol angle brackets < > Description Enclose a variable or value. You must specify the variable or value. For example, in the syntax configure vlan <vlan> ipaddress <ipaddress> you must supply a VLAN name for <vlan name> and an address for <ipaddress> when entering the command. Do not type the angle brackets. square brackets [ ] Enclose a required value or list of required arguments. One or more values or arguments can be specified. For example, in the syntax disable port [<port_list> | all] you must specify either specific ports or all for all ports when entering the command. Do not type the square brackets. vertical bar | Separates mutually exclusive items in a list, one of which must be entered. For example, in the syntax configure snmp add community [readonly | readwrite] <alphanumeric_string> you must specify either the read or write community string in the command. Do not type the vertical bar. braces { } Enclose an optional value or a list of optional arguments. One or more values or arguments can be specified. For example, in the syntax reboot {time <month> <day> <year> <hour> <min> <sec>} {cancel} {warm} {msm <slot_id>} You can specify either a particular date and time combination, or the keyword cancel to cancel a previously scheduled reboot. (In this command, if you do not specify an argument, the command will prompt, asking if you want to reboot the switch now.) Do not type the braces.

Limits
The command line can process up to 4500 characters, including spaces. If you attempt to enter more than 4500 characters, the switch emits an audible beep and will not accept any further input. The first 4500 characters are processed, however.

Port Numbering
ExtremeWare XOS runs on both stand-alone and modular switches, and the port numbering scheme is slightly different on each. This section cover the following topics:

Stand-alone Switch Numerical Ranges on page 43 Modular Switch Numerical Ranges on page 43 NOTE

The keyword all acts on all possible ports; it continues on all ports even if one port in the sequence fails.

42

ExtremeWare XOS 11.3 Concepts Guide

Line-Editing Keys

Stand-alone Switch Numerical Ranges


On a stand-alone switch, such as the Summit X450 switch, the port number is simply noted by the physical port number, as shown below:
5

Separate the port numbers by a dash to enter a range of contiguous numbers, and separate the numbers by a comma to enter a range of noncontiguous numbers:

x-ySpecifies a contiguous series of ports on a stand-alone switch. x,ySpecifies a noncontiguous series of ports on a stand-alone switch. x-y,a,dSpecifies a contiguous series of ports and a noncontiguous series of ports on a stand-alone

switch.

Modular Switch Numerical Ranges


On a modular switch, such as the BlackDiamond 10K, the port number is a combination of the slot number and the port number. The nomenclature for the port number is as follows:
slot:port

For example, if an I/O module that has a total of four ports is installed in slot 2 of the chassis, the following ports are valid:

2:1 2:2 2:3 2:4

You can also use wildcard combinations (*) to specify multiple modular slot and port combinations. The following wildcard combinations are allowed:

slot:*Specifies all ports on a particular I/O module. slot:x-slot:ySpecifies a contiguous series of ports on a particular I/O module. slot:x-ySpecifies a contiguous series of ports on a particular I/O module. slota:x-slotb:ySpecifies a contiguous series of ports that begin on one I/O module and end on another I/O module.

Line-Editing Keys
Table 6 describes the line-editing keys available using the CLI.

Table 6: Line-editing keys


Key(s) Left arrow or [Ctrl] + B Right arrow or [Ctrl] + F [Ctrl] + H or Backspace Delete or [Ctrl] + D [Ctrl] + K Description Moves the cursor one character to the left. Moves the cursor one character to the right. Deletes character to left of cursor and shifts remainder of line to left. Deletes character under cursor and shifts remainder of line to left. Deletes characters from under cursor to end of line.

ExtremeWare XOS 11.3 Concepts Guide

43

Accessing the Switch

Table 6: Line-editing keys (Continued)


Key(s) Insert [Ctrl] + A [Ctrl] + E [Ctrl] + L [Ctrl] + P or Up Arrow [Ctrl] + N or Down Arrow [Ctrl] + U [Ctrl] + W [Ctrl] + C Description Toggles on and off. When toggled on, inserts text and shifts previous text to right. Moves cursor to first character in line. Moves cursor to last character in line. Clears screen and movers cursor to beginning of line. Displays previous command in command history buffer and places cursor at end of command. Displays next command in command history buffer and places cursor at end of command. Clears all characters typed from cursor to beginning of line. Deletes previous word. Interrupts the current CLI command execution.

Command History
ExtremeWare XOS remembers the commands you enter. You can display a list of these commands by using the following command:
history

Common Commands
Table 7 describes some of the common commands used to manage the switch. Commands specific to a particular feature may also be described in other chapters of this guide. For a detailed description of the commands and their options, see the ExtremeWare XOS Command Reference Guide.

Table 7: Common commands


Command clear session [<sessId> | all] configure account <name> Description Terminates a Telnet session from the switch. Configures a user account password. Passwords can have a minimum of 0 character and can have a maximum of 32 characters. Passwords are casesensitive; user names are not case sensitive. configure banner Configures the banner string. You can enter up to 24 rows of 79-column text that is displayed before the login prompt of each session. Press [Return] at the beginning of a line to terminate the command and apply the banner. To clear the banner, press [Return] at the beginning of the first line. Manually configures the port speed and duplex setting of one or more ports on a switch. Configures a slot for a particular I/O module card. NOTE: This command is available only on modular switches.

configure ports <port_list> auto off speed [10 | 100 | 1000 | 10000] duplex [half | full] configure slot <slot> module <module_type>

44

ExtremeWare XOS 11.3 Concepts Guide

Common Commands

Table 7: Common commands (Continued)


Command configure ssh2 key {pregenerated} Description Generates the SSH2 host key. You must install the SSH software module in addition to the base image to run SSH. configure sys-recovery-level [all | none] configure time <month> <day> <year> <hour> <min> <sec> Configures a recovery option for instances where an exception occurs in ExtremeWare XOS. Configures the system date and time. The format is as follows: mm dd yyyy hh mm ss The time uses a 24-hour clock format. You cannot set the year earlier than 2003 or past 2036. configure timezone {name <tz_name>} <GMT_offset> {autodst {name <dst_timezone_ID>} {<dst_offset>} {begins [every <floatingday> | on <absoluteday>] {at <time_of_day>} {ends [every <floatingday> | on <absoluteday>] {at <time_of_day>}}} | noautodst} configure vlan <vlan_name> ipaddress [<ipaddress> {<ipNetmask>} | ipv6-link-local | {eui64} <ipv6_address_mask>] create account [admin | user] <account-name> {encrypted <password> } create vlan <vlan_name> {vr <vrname>} Configures the time zone information to the configured offset from GMT time. The format of GMT_offset is +/minutes from GMT time. The autodst and noautodst options enable and disable automatic Daylight Saving Time change based on the North American standard. Additional options are described in the ExtremeWare XOS Command Reference Guide. Configures an IP address and subnet mask for a VLAN.

Creates a user account. This command is available to admin-level users and to users with RADIUS command authorization. The username is between 1 and 32 characters, the password is between 0 and 32 characters. Creates a VLAN. NOTE: The BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch do not use the vr optional parameter. Deletes a user account. Deletes a VLAN. Disables BOOTP for one or more VLANs. Disables logging of CLI commands to the Syslog. Disables pausing of the screen display when a show command output reaches the end of the page. Disables the timer that disconnects all sessions. After being disabled, console sessions remain open until the switch is rebooted or until you log off. Telnet sessions remain open until you close the Telnet client. Disables one or more ports on the switch. Disables SSH2 Telnet access to the switch. You must install the SSH software module in addition to the base image to run SSH.

delete account <name> delete vlan <vlan_name> disable bootp vlan [<vlan> | all] disable cli-config-logging disable clipaging disable idletimeout

disable port [<port_list> | all] disable ssh2

disable telnet enable bootp vlan [<vlan> | all] enable cli-config-logging

Disables Telnet access to the switch. Enables BOOTP for one or more VLANs. Enables the logging of CLI configuration commands to the Syslog for auditing purposes. The default setting is enabled.

ExtremeWare XOS 11.3 Concepts Guide

45

Accessing the Switch

Table 7: Common commands (Continued)


Command enable clipaging Description Enables pausing of the screen display when show command output reaches the end of the page. The default setting is enabled. Enables a timer that disconnects all sessions (both Telnet and console) after 20 minutes of inactivity. The default setting is enabled. Enables a particular software feature license. Specify <license_key> as an integer. The command unconfigure switch {all} does not clear licensing information. This license cannot be disabled once it is enabled on the switch. enable ssh2 {access-profile [<access_profile> | none]} {port <tcp_port_number>} {vr [<vr_name> | all | default]} Enables SSH2 sessions. By default, SSH2 is disabled. Once enabled, SSH uses TCP port number 22. You must install the SSH software module in addition to the base image to run SSH. Enables Telnet access to the switch. By default, Telnet uses TCP port number 23. Displays the commands entered on the switch. Displays the user-configured banner. Resets all switch parameters (with the exception of defined user accounts, and date and time information) to the factory defaults. If you specify the keyword all, the switch erases the currently selected configuration image in flash memory and reboots. As a result, all parameters are reset to default settings.

enable idletimeout

enable license <key>

enable telnet history show banner unconfigure switch {all}

Accessing the Switch the First Time


With software version 11.2, ExtremeWare XOS adds to the security features offered on your switch. When you take your switch from the box and set it up for the first time, you must connect to the console to access the switch. You are prompted with an interactive script that specifically asks if you want to disable Telnet and SNMP, so these will not be available on your switch at next reboot. This is called the safe defaults mode. Once you connect to the console and log into the switch, the screen displays several interactive questions that lead you through configuring the management access that you want. You disable SNMP, or Telnet access by using the interactive script (refer to Safe Defaults Setup Method on page 47). All ports are enabled in the factory default setting; you can choose to have all unconfigured ports disabled on reboot using the interactive questions. In addition, you can return to the safe defaults mode by issuing the following commands:

unconfigure switch all configure safe-default-script

46

ExtremeWare XOS 11.3 Concepts Guide

Configuring Management Access

Safe Defaults Setup Method


Once you connect to the console port of the switch, or after you issue the unconfigure switch all or configure safe-default-script CLI command, the system returns the following interactive script:
Telnet is enabled by default. Telnet is unencrypted and has been the target of security exploits in the past. Would you like to disable Telnet? [y/N]: No SNMP access is enabled by default. SNMP uses no encryption, SNMPv3 can be configured to eliminate this problem. Would you like to disable SNMP? [y/N]: No All ports are enabled by default. In some secure applications, it maybe more desirable for the ports to be turned off. Would you like unconfigured ports to be turned off by default? [y/N]: No Since you have chosen less secure management methods, please remember to increase the security of your network by taking the following actions: * change your admin password * change your SNMP public and private strings * consider using SNMPv3 to secure network management traffic

All the changes you make using this interactive script can be saved through switch reboots, if you save the setting. If you want to change the management access:

Issue the configure safe-default-script commandmaintains your configuration and reruns the script Issue the unconfigure switch all commandresets your switch to the default factory setting and reruns this script

You see this interactive script only under the following conditions:

Initial login (when you use the switch the first time) After unconfigure switch all CLI command After configure safe-default-script command

Configuring Management Access


ExtremeWare XOS supports the following two levels of management:

User Administrator

In addition to the management levels, you can optionally use an external RADIUS server to provide CLI command authorization checking for each command. For more information on RADIUS, see Chapter 16.

ExtremeWare XOS 11.3 Concepts Guide

47

Accessing the Switch

User Account
A user-level account has viewing access to all manageable parameters, with the exception of:

User account database. SNMP community strings.

A person with a user-level account can use the ping command to test device reachability and change the password assigned to the account name. If you have logged on with user capabilities, the command line prompt ends with a (>) sign. For example:
BD-1.2 >

Administrator Account
A person with an administrator-level account can view and change all switch parameters. With this level, you can also add and delete users, as well as change the password associated with any account name (to erase the password, issue the unconfigure switch all command). The administrator can disconnect a management session that has been established by way of a Telnet connection. If this happens, the user logged on by way of the Telnet connection is notified that the session has been terminated. If you have logged on with administrator capabilities, the command line prompt ends with a (#) sign. For example:
BD-1.18 #

Prompt Text
You must have an administrator-level account to change the text of the prompt. The prompt text is taken from the SNMP sysname setting. The number that follows the colon indicates the sequential line of the specific command or line. If an asterisk (*) appears in front of the command line prompt, it indicates that you have outstanding configuration changes that have not been saved. For example:
* BD-1.19 #

Default Accounts
By default, the switch is configured with two accounts, as shown in Table 8.

Table 8: Default accounts


Account Name admin user Access Level This user can access and change all manageable parameters. However, the user may not delete all admin accounts. This user can view (but not change) all manageable parameters, with the following exceptions: This user cannot view the user account database. This user cannot view the SNMP community strings.

48

ExtremeWare XOS 11.3 Concepts Guide

Configuring Management Access To change the password on the default account, see Applying a Password to the Default Account on page 50.

Creating a Management Account


The switch can have a total of 16 management accounts. You can use the default names (admin and user), or you can create new names and passwords for the accounts. Passwords can have a minimum of 0 characters and a maximum of 32 characters. To create a new account: 1 Log in to the switch as admin. 2 At the password prompt, press [Return], or enter the password that you have configured for the admin account. 3 Add a new user by using the following command:
create account [admin | user] <account-name> {encrypted <password> }

If you do not want a password associated with the specified account, press Enter twice.

Viewing Accounts
To view the accounts that have been created, you must have administrator privileges. To see the accounts, use the following command:
show accounts

Deleting an Account
To delete a account, you must have administrator privileges. To delete an account, use the following command:
delete account <name>

Failsafe Account
The failsafe account is the account of last resort to access your switch. This account is never displayed by the show accounts command, but it is always present on the switch. To configure the account name and password for the failsafe account, use the following command:
configure failsafe-account

You will be prompted for the failsafe account name and prompted twice to specify the password for the account. For example:
BD-10808.1 # configure failsafe-account enter failsafe user name: blue5green enter failsafe password: enter password again: BD-10808.2

The failsafe account is immediately saved to NVRAM.

ExtremeWare XOS 11.3 Concepts Guide

49

Accessing the Switch

NOTE
The information that you use to configure the failsafe account cannot be recovered by Extreme Networks. Technical support cannot retrieve passwords or account names for this account. Protect this information carefully.

To access your switch using the failsafe account, you must connect to the serial port of the switch. You cannot access the failsafe account through any other port. At the switch login prompt, carefully enter the failsafe account name. If you enter an erroneous account name, you cannot re-enter the correct name. Once you have entered the failsafe account name, you are prompted to enter the password. You will have three tries to enter the password correctly. Once you have successfully logged in to the failsafe account, you see the following prompt:
failsafe>

From here, you have the following four command choices:


LoginUse this command to access the switch CLI. You will have full administrator capabilities. RebootUse this command to reboot the current MSM (MSM on modular switches only). HelpUse this command to display a short help text. ExitUse this command to exit the failsafe account and return to the login prompt.

Typically, you use the Login command to correct the problem that initially required you to use the failsafe account.

Managing Passwords
When you first access the switch you, have a default account. You configure a password for your default account. As you create other accounts (see Creating a Management Account on page 49), you configure passwords for those accounts. Beginning with ExtremeWare XOS version 11.2, the software allows you to apply additional security to the passwords. You can enforce a specific format and minimum length for the password. Additionally, you can age out the password, prevent a user from employing a previously used password, and lock users out of the account after three consecutive failed login attempts. This section discusses the following topics:

Applying a Password to the Default Account on page 50 Applying Security to Passwords on page 51 Displaying Passwords on page 52

Applying a Password to the Default Account


Default accounts do not have passwords assigned to them. Passwords can have a minimum of 0 character and can have a maximum of 32 characters. (If you specify the format of passwords using the configure account password-policy char-validation command, the minimum is 8 characters.)

50

ExtremeWare XOS 11.3 Concepts Guide

Managing Passwords

NOTE
Passwords are case-sensitive; user names are not case-sensitive.

To add a password to the default admin account: 1 Log in to the switch using the name admin. 2 At the password prompt, press [Return]. 3 Add a default admin password of green by entering the following command:
configure account admin green

To add a password to the default user account: 1 Log in to the switch using the name user. 2 At the password prompt, press [Return], or enter the password that you have configured for the admin account. 3 Add a default user password by blue entering the following command:
configure account user blue

NOTE
If you forget your password while logged out of the CLI, contact your local technical support representative, who will advise on your next course of action.

Applying Security to Passwords


You can increase the security of your system by enforcing password restrictions, which will make it more difficult for unauthorized users to access your system. You can specify that each password must include at least two characters of each of the following four character types:

Upper-case A-Z Lower-case a-z 0-9 !, @, #, $, %, ^, *, (, )

To set this format for the password, issue the following command:
configure account [all | <name>] password-policy char-validation [none | all-chargroups]

You can enforce a minimum length for the password and set a maximum time limit, after which the password will not be accepted. To set a minimum length for the password, issue the following command:
configure account [all | <name>] password-policy min-length [<num_characters> | none]

ExtremeWare XOS 11.3 Concepts Guide

51

Accessing the Switch To age out the password after a specified time, issue the following command:
configure account [all | <name>] password-policy max-age [<num_days> | none]

You can block users from employing previously used passwords by issuing the command:
configure account [all | <name>] password-policy history [<num_passwords> | none]

By default, the system terminates a session once the user has 3 consecutive failed login attempts. The user may then launch another session (which again would terminate after 3 consecutive failed login attempts). To increase security, you can lock users out of the system entirely after 3 failed consecutive login attempts. To use this feature, issue the following command:
configure account [all | <name>] password-policy lockout-on-login-failures [on | off]

NOTE
If you are not working on SSH, you can configure the number of failed logins that trigger lockout, using the configure cli max-failed-logins <num-of-logins> command. (This command also sets the number of failed logins that terminate the particular session.)

Once locked out (using the configure account password-policy lockout-on-login-failures command), the users account must be specifically re-enabled by an administrator. To re-enable a locked-out account, issue the following command:
clear account [all | <name>] lockout

Selecting the all option affects the setting of all existing and future new accounts.

NOTE
The default admin account and failsafe accounts are never locked out, no matter how many consecutive failed login attempts.

Displaying Passwords
To display the accounts and any applied password security, issue the following command:
show accounts password-policy

The following output shows a sample display from the show accounts password-policy command:
--------------------------------------------------------------------------Accounts global configuration(applied to new accounts on creation) --------------------------------------------------------------------------Password Max. age : None Password History limit : None Password Min. length : None Password Character Validation : Disabled Accts. lockout on login failures: Disabled Accounts locked out : No ---------------------------------------------------------------------------

52

ExtremeWare XOS 11.3 Concepts Guide

Access to Both MSM Console PortsModular Switches Only


Password Password Password Password Flags Expiry Max. age Min. len History Date Limit --------------------------------------------------------------------------admin None None None --user None None None --test Apr-17-2005 12 32 9 C---------------------------------------------------------------------------Flags: (C) Password character validation enabled, (L) Account locked out (l) Account lockout on login failures enabled User Name

You can also display which accounts may be locked out by issuing the following command:
show accounts

The following shows a sample display from the show accounts command:
User Name Access LoginOK Failed ---------------- ------ ------- -----admin R/W 3 1 user RO 0 0 dbackman R/W 0 0 ron* RO 0 0 nocteam RO 0 0 ---------------------------------------(*) - Account locked

Access to Both MSM Console PortsModular Switches Only


With ExtremeWare XOS version 11.2, you can access either the primary or the backup MSM regardless of which console port you are connected to. Use the following command:
telnet msm [a | b]

Domain Name Service Client Services


The Domain Name Service (DNS) client in ExtremeWare XOS augments the following commands to allow them to accept either IP addresses or host names:

telnet download bootrom download image ping traceroute configure radius server configure tacacs server

ExtremeWare XOS 11.3 Concepts Guide

53

Accessing the Switch In addition, the nslookup utility can be used to return the IP address of a hostname. (This command is available only on the Default VR on the BlackDiamond 10K switch.) You can specify up to eight DNS servers for use by the DNS client using the following command:
configure dns-client add

You can specify a default domain for use when a host name is used without a domain. Use the following command:
configure dns-client default-domain

For example, if you specify the domain xyz-inc.com as the default domain, then a command such as ping accounting1 will be taken as if it had been entered ping accounting1.xyz-inc.com.

Checking Basic Connectivity


NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support user-created virtual routers. You must use the vr option for these commands when running them on VR-Mgmt.

The switch offers the following commands for checking basic connectivity:

ping traceroute

Ping
The ping command enables you to send Internet Control Message Protocol (ICMP) echo messages to a remote IP device. The ping command is available for both the user and administrator privilege level. Beginning with ExtremeWare XOS version 11.2, you can ping an IPv6 address. The ping command syntax is:
ping {count <count> {start-size <start-size>} | continuous {start-size <start-size>} | {start-size <start-size> {end-size <end-size>}}} {udp} {dont-fragment} {ttl <ttl>} {tos <tos>} {interval <interval>} {vr <vrid>} {ipv4 <host> | ipv6 <host>} {from} {with record-route}

Options for the ping command are described in Table 9.

Table 9: Ping command parameters


Parameter count start-size continuous Description Specifies the number of ping requests to send. Specifies the size, in bytes, of the packet to be sent, or the starting size if incremental packets are to be sent. Specifies that UDP or ICMP echo messages to be sent continuously. This option can be interrupted by pressing [Ctrl] + C.

54

ExtremeWare XOS 11.3 Concepts Guide

Checking Basic Connectivity

Table 9: Ping command parameters (Continued)


Parameter end-size udp dont-fragment ttl tos interval vr Description Specifies an end size for packets to be sent. Specifies that the ping request should use UDP instead of ICMP. Sets the IP to not fragment the bit. Sets the TTL value. Sets the TOS value. Sets the time interval between sending out ping requests. Specifies the virtual router name to use for sending out the echo message. If not specified, VR-Default is used. NOTE: The BlackDiamond 8800 family of switches and the Summit X450 switch does not support user-created VRs. ipv4 ipv6 Specifies IPv4 transport. Specifies IPv6 transport. NOTE: If you are contacting an IPv6 link local address, you must specify the VLAN you sending the message from: ping <ipv6> <link-local address> %<vlan_name> <host>. host from with record-route Specifies a host name or IP address (either v4 or v6). Uses the specified source address. If not specified, the address of the transmitting interface is used. Sets the traceroute information.

If a ping request fails, the switch stops sending the request after three attempts. Press [Ctrl] + C to interrupt a ping request earlier. The statistics are tabulated after the ping is interrupted or stops. You use the ipv6 variable to ping an IPv6 host by generating an ICMPv6 echo request message and sending the message to the specified address. If you are contacting an IPv6 link local address, you must specify the VLAN you are sending the message from, as shown in the following example (you must include the % sign): ping <ipv6> <link-local address> %<vlan_name> <host>.

Traceroute
The traceroute command enables you to trace the routed path between the switch and a destination endstation. The traceroute command syntax is:
traceroute {vr <vrid>} {ipv4 <host>} {ipv6 <host>} {ttl <number>} {from <from>} {[port <port>] | icmp}

where:

vr is the name of the virtual router (the BlackDiamond 8800 family of switches and the Summit

X450 switch do not support user-created VRs).


ipv4/ipv6 is the transport. from uses the specified source address in the ICMP packet. If not specified, the address of the transmitting interface is used. host is the host of the destination endstation. To use the hostname, you must first configure DNS. ttl configures the switch to trace the hops until the time-to-live has been exceeded for the switch. port uses the specified UDP port number.

ExtremeWare XOS 11.3 Concepts Guide

55

Accessing the Switch

icmp uses ICMP echo messages to trace the routed path.

Beginning with ExtremeWare XOS, you can trace the route between the switch and an IPv6 address. However, you must specify the targets IPv6 address to use this command.

Displaying Switch Information


To display basic information about the switch, issue the following command:
show switch

Output from this command on a modular switch looks similar to the following:
SysName: SysLocation: SysContact: System MAC: SysHealth check: Recovery Mode: System Watchdog: Current Time: Timezone: BD-10808 support@extremenetworks.com, +1 888 257 3000 00:30:48:41:ED:45 Enabled None Enabled Wed May 19 11:04:32 2004 [Auto DST Enabled] GMT Offset: -480 minutes, name is PST. DST of 0 minutes is currently in effect, name is PDT. DST begins every first Sunday April at 2:00 DST ends every last Sunday October at 2:00 Sat May 15 17:19:29 2004 None scheduled

Boot Time: Next Reboot:

MSM: Current State: Image Selected: Image Booted: Primary ver: Secondary ver: Config Selected: Config Booted: primary.cfg

MSM-A * -----------------------MASTER primary primary 11.1.0.14 11.1.0.14 primary.cfg primary.cfg

MSM-B -----------------------INIT

Created by ExtremeWare XOS version 10.2.0.14 223 bytes saved on Fri May 14 13:36:37 2004

Output from this command on a stand-alone switch looks similar to the following:
SysName: SysLocation: SysContact: System MAC: System Watchdog: SummitX450-24x support@extremenetworks.com, +1 888 257 3000 00:04:96:1F:A5:3E Enabled

56

ExtremeWare XOS 11.3 Concepts Guide

Displaying Switch Information


Current Time: Timezone: Boot Time: Next Reboot: Sat Feb 14 04:57:33 2004 [Auto DST Disabled] GMT Offset: 0 minutes, name is UTC. Fri Feb 13 23:57:48 2004 None scheduled

Current State: Image Selected: Image Booted: Primary ver: Secondary ver: Config Selected: Config Booted: primary.cfg

OPERATIONAL primary primary 11.2.0.16 11.2.0.10 primary.cfg primary.cfg Created by ExtremeWare XOS version 11.2.0.16 93463 bytes saved on Sat Feb 14 04:24:31 2004

ExtremeWare XOS 11.3 Concepts Guide

57

Accessing the Switch

58

ExtremeWare XOS 11.3 Concepts Guide

Managing the Switch

This chapter covers the following topics:


Overview on page 59 Understanding the ExtremeWare XOS Shell on page 60 Using the Console Interface on page 60 Using the 10/100 Ethernet Management Port on page 61 Using EPICenter to Manage the Network on page 61 Authenticating Users on page 62 Using Telnet on page 62 Using Secure Shell 2 on page 69 Using the Trivial File Transfer Protocol on page 69 Understanding System Redundancy with Dual MSMs InstalledModular Switches Only on page 70 Understanding Hitless Failover SupportModular Switches Only on page 74 Understanding Power Supply Management on page 78 Using the Simple Network Management Protocol on page 82 Using the Simple Network Time Protocol on page 92

Overview
Using ExtremeWare XOS, you can manage the switch using the following methods:

Access the command line interface (CLI) by connecting a terminal (or workstation with terminalemulation software) to the console port. Access the switch remotely using TCP/IP through one of the switch ports or through the dedicated 10/100 unshielded twisted pair (UTP) Ethernet management port. Remote access includes:

Telnet using the CLI interface. Secure Shell (SSH2) using the CLI interface. Simple Network Management Protocol (SNMP) access using EPICenter or another SNMP manager.

Download software updates and upgrades. For more information, see Appendix A, Software Upgrade and Boot Options. NOTE

Beginning with ExtremeWare XOS 11.2, the switch accepts IPv6 Telnet and SSH2 connections.

The switch supports up to the following number of concurrent user sessions:

One console session

Two console sessions are available if two management modules are installed.

ExtremeWare XOS 11.3 Concepts Guide

59

Managing the Switch


Eight shell sessions Eight Telnet sessions Eight Trivial File Transfer Protocol (TFTP) sessions Eight SSH2 sessions

Understanding the ExtremeWare XOS Shell


When you log in to ExtremeWare XOS from a terminal, you enter the shell with a shell prompt displayed. At the prompt, you input the commands to be executed on the switch. After the switch processes and executes a command, the results are relayed to and displayed on your terminal. The shell supports ANSI, VT100, and XTERM terminal emulation and adjusts to the correct terminal type and window size. In addition, the shell supports UNIX-style page view for page-by-page command output capability. By default, up to eight active shell sessions can access the switch concurrently; however, you can change the number of simultaneous, active shell sessions supported by the switch. You can configure up to 16 active shell sessions. Configurable shell sessions include both Telnet and SSH connections (not console CLI connections). If only eight active shell sessions can access the switch, a combination of eight Telnet and SSH connections can access the switch even though Telnet and SSH each support eight connections. For example, if you have six Telnet sessions and two SSH sessions, no one else can access the switch until a connection is terminated or you access the switch via the console. If you configure a new limit, only new incoming shell sessions are affected. If you decrease the limit and the current number of sessions already exceeds the new maximum, the switch refuses only new incoming connections until the number of shell session drops below the new limit. Already connected shell sessions are not disconnected as a result of decreasing the limit. To configure the number of shell sessions accepted by the switch, use the following command:
configure cli max-sessions

For more information about the line-editing keys that you can use with the XOS shell, see Line-Editing Keys on page 43.

Using the Console Interface


The CLI built into the switch is accessible by way of the 9-pin, RS-232 port labeled console, located on the front of the Management Switch Fabric Module (MSM). NOTE
For more information on the console port pinouts, see the hardware installation guide that shipped with your switch.

After the connection has been established, you see the switch prompt and you can log in.

60

ExtremeWare XOS 11.3 Concepts Guide

Using the 10/100 Ethernet Management Port

Using the 10/100 Ethernet Management Port


The MSM provides a dedicated 10/100 mbps Ethernet management port. This port provides dedicated remote access to the switch using TCP/IP. It supports the following management methods:

Telnet/SSH2 using the CLI interface SNMP access using EPICenter or another SNMP manager

The switch uses the Ethernet management port only for host operation, not for switching or routing. The TCP/IP configuration for the management port is done using the same syntax as used for virtual LAN (VLAN) configuration. The VLAN mgmt comes preconfigured with only the management port as a member. The management port is a member of the virtual router VR-Mgmt. When you configure the IP address for the VLAN mgmt, this address gets assigned to the primary MSM. You can connect to the management port on the primary MSM for any switch configuration. The management port on the backup MSM is available only when failover occurs. At that time, the primary MSM relinquishes its role, the backup MSM takes over, and the VLAN mgmt on the new primary MSM acquires the IP address of the previous primary MSM. To configure the IP address and subnet mask for the VLAN mgmt, use the following command:
configure vlan mgmt ipaddress <ip_address>/<subnet_mask>

To configure the default gateway (you must specify VR-Mgmt for the management port and VLAN mgmt), use the following command:
configure iproute add default <gateway> {vr <vrname>} {<metric>} {multicast-only | unicast-only}

The following example configuration sets the management port IP address to 192.168.1.50, mask length of 25, and configures the gateway to use 192.168.1.1:
configure vlan mgmt ipaddress 192.168.1.50/25 configure iproute add default 192.168.1.1 vr vr-mgmt

Using EPICenter to Manage the Network


EPICenter is a powerful yet easy-to-use application suite that facilitates the management of a network of Extreme Networks switches, as well as selected third-party switches. EPICenter offers a comprehensive set of network management tools that are easy to use from a client workstation running EPICenter client software, or from a workstation configured with a web browser and the Java plug-in. For more information about the EPICenter management software available from Extreme Networks, go to http://www.extremenetworks.com To review the EPICenter documentation, go to http://www.extremenetworks.com/services/swuserguides.asp

ExtremeWare XOS 11.3 Concepts Guide

61

Managing the Switch

Authenticating Users
ExtremeWare XOS provides three methods to authenticate users who log in to the switch:

RADIUS client TACACS+ Local database of accounts and passwords NOTE

You cannot configure RADIUS and TACACS+ at the same time.

RADIUS Client
Remote Authentication Dial In User Service (RADIUS, RFC 2138) is a mechanism for authenticating and centrally administrating access to network nodes. The ExtremeWare XOS RADIUS client implementation allows authentication for Telnet or console access to the switch. For detailed information about RADIUS and configuring a RADIUS client, see Chapter 16, Security.

TACACS+
Terminal Access Controller Access Control System Plus (TACACS+) is a mechanism for providing authentication, authorization, and accounting on a central server, similar in function to the RADIUS client. The ExtremeWare XOS version of TACACS+ is used to authenticate prospective users who are attempting to administer the switch. TACACS+ is used to communicate between the switch and an authentication database. For detailed information about TACACS+ and configuring TACACS+, see Chapter 16, Security.

Management Accounts
ExtremeWare XOS supports two levels of management accounts (local database of accounts and passwords): User and Administrator. A user level account can view but not change all manageable parameters, with the exception of the user account database and SNMP community strings. An administrator level account can view and change all manageable parameters. For detailed information about configuring management accounts, see Chapter 2, Accessing the Switch.

Using Telnet
ExtremeWare XOS supports the Telnet Protocol based on RFC 854. Telnet allows interactive remote access to a device and is based on a client/server model. ExtremeWare XOS uses Telnet to connect to other devices from the switch (client) and to allow incoming connections for switch management using the CLI (server).

62

ExtremeWare XOS 11.3 Concepts Guide

Using Telnet This section describes the following Telnet topics:


About the Telnet Client on page 63 About the Telnet Server on page 63 Connecting to Another Host Using Telnet on page 64 Configuring Switch IP Parameters on page 64 Configuring Telnet Access to the Switch on page 66 Disconnecting a Telnet Session on page 68

About the Telnet Client


Before you can start an outgoing Telnet session on the switch, you must set up the IP parameters described in Configuring Switch IP Parameters on page 64. Telnet is enabled and uses VR-Mgmt by default. NOTE
Maximize the Telnet screen so that automatically updating screens display correctly.

If you use Telnet to establish a connection to the switch, you must specify the IP address or host name of the device that you want to connect to. Check the user manual supplied with the Telnet facility if you are unsure of how to do this. After the connection is established, you see the switch prompt and you can log in. The same is true if you use the switch to connect to another host. From the CLI, you must specify the IP address or host name of the device that you want to connect to. If the host is accessible and you are allowed access, you may log in. For more information about using the Telnet client on the switch, see Connecting to Another Host Using Telnet on page 64.

About the Telnet Server


Any workstation with a Telnet facility should be able to communicate with the switch over a TCP/IP network using VT100 terminal emulation. Up to eight active Telnet sessions can access the switch concurrently. If you enable the idletimeouts parameter, the Telnet connection times out after 20 minutes of inactivity. If a connection to a Telnet session is lost inadvertently, the switch terminates the session within two hours. Beginning with ExtremeWare XOS 11.2, the switch accepts IPv6 connections. For information about the Telnet server on the switch, see the following sections:

Configuring Telnet Access to the Switch on page 66 Disconnecting a Telnet Session on page 68

ExtremeWare XOS 11.3 Concepts Guide

63

Managing the Switch

Connecting to Another Host Using Telnet


You can Telnet from the current CLI session to another host using the following command:
telnet {vr <vr_name>} [<host_name> | <remote_ip>] {<port>}

NOTE
The BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch do not support user-created VRs.

If the TCP port number is not specified, the Telnet session defaults to port 23. If the virtual router name is not specified, the Telnet session defaults to VR-Mgmt. Only VT100 emulation is supported. Beginning with ExtremeWare XOS 11.2, you can use Telnet to access either the primary or the backup MSM regardless of which console port you are connected to. For more information see Chapter 2, Accessing the Switch.

Configuring Switch IP Parameters


To manage the switch by way of a Telnet connection or by using an SNMP Network Manager, you must first configure the switch IP parameters.

Using a BOOTP or DHCP Server


If you are using IP and you have a Bootstrap Protocol (BOOTP) server set up correctly on your network, you must provide the following information to the BOOTP server:

Switch Media Access Control (MAC) address, found on the rear label of the switch IP address Subnet address mask (optional)

The switch contains a Bootstrap Protocol (BOOTP) and Dynamic Host Configuration Protocol (DHCP) client, so if you have a BOOTP or DHCP server in your IP network, you can have it assign IP addresses to the switch. This is more likely to be desirable on the switch's VLAN mgmt than it is on any other VLANs. You can enable the BOOTP or DHCP client per VLAN by using the following commands:
enable bootp vlan [<vlan> | all] enable dhcp vlan [<vlan_name> | all]

You can disable the BOOTP or DHCP client per VLAN by using the following commands:
disable bootp vlan [<vlan> | all] disable dhcp vlan [<vlan_name> | all]

To view the current state of the BOOTP or DHCP client, use the following command:
show dhcp-client state

The switch does not retain IP addresses assigned by BOOTP or DHCP through a power cycle, even if the configuration has been saved. To retain the IP address through a power cycle, you must configure the IP address of the VLAN using the CLI or Telnet.

64

ExtremeWare XOS 11.3 Concepts Guide

Using Telnet If you need the switch's MAC address to configure your BOOTP or DHCP server, you can find it on the rear label of the switch. Note that all VLANs configured to use BOOTP or DHCP use the same MAC address to get their IP address, so you cannot configure the BOOTP or DHCP server to assign multiple specific IP addresses to a switch depending solely on the MAC address.

Manually Configuring the IP Settings


If you are using IP without a BOOTP server, you must enter the IP parameters for the switch in order for the SNMP Network Manager or Telnet software to communicate with the device. To assign IP parameters to the switch, you must perform the following tasks:

Log in to the switch with administrator privileges using the console interface. Assign an IP address and subnet mask to a VLAN. The switch comes configured with a default VLAN named default. To use Telnet or an SNMP Network Manager, you must have at least one VLAN on the switch, and that VLAN must be assigned an IP address and subnet mask. IP addresses are always assigned to each VLAN. The switch can be assigned multiple IP addresses (one for each VLAN). NOTE

For information on creating and configuring VLANs, see Chapter 9.

To manually configure the IP settings: 1 Connect a terminal or workstation running terminal emulation software to the console port, as detailed in Using the Console Interface on page 60. 2 At your terminal, press [Return] one or more times until you see the login prompt. 3 At the login prompt, enter your user name and password. Note that they are both case-sensitive. Ensure that you have entered a user name and password with administrator privileges.

If you are logging in for the first time, use the default user name admin to log in with administrator privileges. For example:
login: admin

Administrator capabilities enable you to access all switch functions. The default user names have no passwords assigned.

If you have been assigned a user name and password with administrator privileges, enter them at the login prompt.

4 At the password prompt, enter the password and press [Return]. When you have successfully logged in to the switch, the command line prompt displays the name of the switch. 5 Assign an IP address and subnetwork mask for the default VLAN by using the following command:
configure vlan <vlan_name> ipaddress [<ipaddress> {<ipNetmask>} | ipv6-link-local | {eui64} <ipv6_address_mask>]

For example:
configure vlan default ipaddress 123.45.67.8 255.255.255.0

Your changes take effect immediately.

ExtremeWare XOS 11.3 Concepts Guide

65

Managing the Switch

NOTE
As a general rule, when configuring any IP addresses for the switch, you can express a subnet mask by using dotted decimal notation or by using classless inter domain routing notation (CIDR). CIDR uses a forward slash plus the number of bits in the subnet mask. Using CIDR notation, the command identical to the previous example is: configure vlan default ipaddress 123.45.67.8/24

6 Configure the default route for the switch using the following command:
configure iproute add default <gateway> {vr <vrname>} {<metric>} {multicast-only | unicast-only}

For example:
configure iproute add default 123.45.67.1

7 Save your configuration changes so that they will be in effect after the next switch reboot.

If you want to save your changes to the currently booted configuration, use the following command:
save

ExtremeWare XOS allows you to select or create a configuration file name of your choice to save the configuration to. If you want to save your changes to an existing or new configuration file, use the following command:
save configuration [<existing-config> | <new-config>]

8 When you are finished using the facility, log out of the switch by typing:
logout or quit

Configuring Telnet Access to the Switch


By default, Telnet services are enabled on the switch and all virtual routers listen for incoming Telnet requests. Beginning with ExtremeWare XOS 11.2, the switch accepts IPv6 connections. NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support user-created virtual routers.

ExtremeWare XOS 11.2 introduces the concept of safe defaults mode. Safe defaults mode runs an interactive script that allows you to enable or disable SNMP, Telnet, and switch ports. When you set up your switch for the first time, you must connect to the console port to access the switch. After logging in to the switch, you enter safe defaults mode. Although SNMP, Telnet, and switch ports are enabled by default, the script prompts you to confirm those settings. If you choose to keep the default setting for Telnetthe default setting is enabledthe switch returns the following interactive script:
Since you have chosen less secure management methods, please remember to increase the security of your network by taking the following actions: * change your admin password * change your SNMP public and private strings * consider using SNMPv3 to secure network management traffic

For more detailed information about safe defaults mode, see Safe Defaults Setup Method on page 47.

66

ExtremeWare XOS 11.3 Concepts Guide

Using Telnet To configure the virtual router from which you receive a Telnet request, use the following command:
configure telnet vr [all | default | <vr_name>]

To change the default TCP port number, use the following command:
configure telnet port [<portno> | default]

The range for the port number is 1 through 65535. The following TCP port numbers are reserved and cannot be used for Telnet connections: 22, 80, and 1023. If you attempt to configure a reserved port, the switch displays an error message.

Using ACLs to Control Telnet Access


By default, Telnet services are enabled on the switch. You can restrict Telnet access by using an access control list (ACL) and implementing an ACL policy. You configure an ACL policy to permit or deny a specific list of IP addresses and subnet masks for the Telnet port. There are two methods to load ACL policies to the switch:

Use the edit policy command to launch a VI-like editor on the switch. You can create the policy directly on the switch. Use the tftp command to transfer a policy that you created using a text editor on another system to the switch.

For more information about creating and implementing ACLs and policies, see, see Chapter 12, Policy Manager and Chapter 13, Access Lists (ACLs). Sample ACL Policies. The following are sample policies that you can apply to restrict Telnet access. In the following example named MyAccessProfile.pol, the switch permits connections from the subnet 10.203.133.0/24 and denies connections from all other addresses:
MyAccessProfile.pol Entry AllowTheseSubnets { if { source-address 10.203.133.0 /24; } then { permit; } }

In the following example named MyAccessProfile_2.pol, the switch does not permit connections from the subnet 10.203.133.0/24 but accepts connections from all other addresses:
MyAccessProfile_2.pol Entry dontAllowTheseSubnets { if { source-address 10.203.133.0 /24; } then { deny;

ExtremeWare XOS 11.3 Concepts Guide

67

Managing the Switch


} } Entry AllowTheRest { If { ; #none specified } then { permit; } }

Configuring Telnet to Use ACL Policies. This section assumes that you have already loaded the policy on the switch. For more information about creating and implementing ACLs and policies, see Chapter 12, Policy Manager and Chapter 13, Access Lists (ACLs). To configure Telnet to use an ACL policy to restrict Telnet access, use the following command:
configure telnet access-profile [<access_profile> | none]

Use the none option to remove a previously configured ACL.

Viewing Telnet Information


To display the status of Telnet, including the current TCP port, the virtual router used to establish a Telnet session, and whether ACLs are controlling Telnet access, use the following command:
show management

Disabling and Enabling Telnet


You can choose to disable Telnet by using the following command:
disable telnet

To re-enable Telnet on the switch, use the following command:


enable telnet

You must be logged in as an administrator to configure the virtual router(s) used by Telnet and to enable or disable Telnet.

Disconnecting a Telnet Session


A person with an administrator level account can disconnect a Telnet management session. If this happens, the user logged in by way of the Telnet connection is notified that the session has been terminated. To terminate a Telnet session: 1 Log in to the switch with administrator privileges.

68

ExtremeWare XOS 11.3 Concepts Guide

Using Secure Shell 2 2 Determine the session number of the session you want to terminate by using the following command:
show session {{detail} {<sessID>}} {history}

3 Terminate the session by using the following command:


clear session [<sessId> | all]

Using Secure Shell 2


Secure Shell 2 (SSH2) is a feature of ExtremeWare XOS that allows you to encrypt session data between a network administrator using SSH2 client software and the switch. Configuration and policy files may also be transferred to the switch using the Secure Copy Program 2 (SCP2). Beginning with ExtremeWare XOS 11.2, you can also use SSH2 to connect to other devices from the switch. The ExtremeWare XOS CLI provides a command that enables the switch to function as an SSH2 client, sending commands to a remote system via an SSH2 session. Beginning with ExtremeWare XOS 11.2, the switch accepts IPv6 connections. Up to eight active SSH2 sessions can run on the switch concurrently. For detailed information about SSH2, see Chapter 16, Security.

Using the Trivial File Transfer Protocol


ExtremeWare XOS supports the Trivial File Transfer Protocol (TFTP) based on RFC 1350. TFTP is a method used to transfer files from one network device to another. The ExtremeWare XOS TFTP client is a command line application used to contact an external TFTP server on the network. For example, ExtremeWare XOS uses TFTP to download software image files, switch configuration files, and ACLs from a server on the network to the switch. Up to eight active TFTP sessions can run on the switch concurrently. For detailed information about downloading software image files, BootROM files, and switch configurations, see Chapter A, Software Upgrade and Boot Options. Extreme Networks recommends using a TFTP server that supports blocksize negotiation (as described in RFC 2348, TFTP Blocksize Option), to enable faster file downloads and larger file downloads. For detailed information about downloading ACL (and other) policy files, see Chapter 12, Policy Manager.

Connecting to Another Host Using TFTP


You can TFTP from the current CLI session to another host using the following command:
tftp [<host_name> | <ip_address>] {-v <vr_name>} [-g | -p] [{-l [<local_file> | memorycard <local-file-memcard>]} {-r <remote_file>} | {-r <remote_file>} {-l [<local_file> | memorycard <local-file-memcard]}]

ExtremeWare XOS 11.3 Concepts Guide

69

Managing the Switch

NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support user-created VRs.

The TFTP session defaults to port 69. If you do not specify a virtual router, VR-Mgmt is used. For example, to connect to a remote TFTP server with an IP address of 10.123.45.67 and get or retrieve an ExtremeWare XOS configuration file named XOS1.cfg from that host, use the following command:
tftp 10.123.45.67 -g -r XOS1.cfg

When you get the file via TFTP, the switch saves the file to the primary MSM. If the switch detects a backup MSM in the running state, the file is replicated to the backup MSM. To view the files you retrieved, enter the ls command at the command prompt.

Understanding System Redundancy with Dual MSMs InstalledModular Switches Only


If you install two MSMs in the chassis, one assumes the role of master (primary) and the other assumes the role of backup. The master MSM provides all of the switch management functions including bringing up and programming the I/O modules, running the bridging and routing protocols, and configuring the switch. The master MSM also synchronizes the backup MSM in case it needs to take over the management functions if the master MSM fails.

Node Election
Node election is based on leader election between the MSMs installed in the chassis. The MSM installed in slot A has master status. The Device Manager collects the node health information and forwards that information to the Node Manager. The Node Manager then computes the quality of the node which is later used in leader election. When two nodes exchange their health information, they determine the healthier node. Based on the election results obtained from all of the nodes, the healthiest node wins the election criteria. At the end of the election process, a master is selected. The master MSM runs the switch management functions, and the backup MSM is available if the master fails.

Determining the Master Node


The master node is determined by the following parameters:

Node stateThe node state must be STANDBY to participate in leader election and be selected master. If the node is in the INIT, DOWN, or FAIL states, it cannot participate in leader election. For more information about the node states, see Viewing Node Status on page 73. Configuration priorityThis is a user assigned priority. The configured priority is compared only after the node meets the minimum thresholds in each category for it to be healthy. Required processes and devices must not fail. Software healthThis represents the percent of processes available.

70

ExtremeWare XOS 11.3 Concepts Guide

Understanding System Redundancy with Dual MSMs InstalledModular Switches Only

Health of secondary hardware componentsThis represents the health of the switch components, such as power supplies, fans, and so forth. Slot IDThe MSM slot where the node is installed (MSM-A or MSM-B).

Configuring the Node Priority


To configure the priority of an MSM node, use the following command:
configure node slot <slot_id> priority <node_pri>

If you do not configure any priorities, MSM-A has a higher priority than MSM-B. For the slot_id parameter, enter A for the MSM installed in slot A or B for the MSM installed in slot B. By default, the priority is 0 and the node priority range is 1 through 100. The lower the value, the higher the priority.

Relinquishing Master Status


You can cause the master to failover to the backup, thereby relinquishing its master status. To cause the failover, complete the following steps: 1 Use the show switch {detail} command to confirm that the nodes are synchronized and have identical software and switch configurations before failover. The output displays the status of the MSMs, with the master MSM showing MASTER and the backup MSM showing BACKUP (InSync). A node may not be synchronized because checkpointing did not occur, incompatible software is running on the master and backup, or the backup is down.

If the nodes are not synchronized, and both MSMs are running ExtremeWare XOS 11.0 or later, proceed to step 2. If the nodes are not synchronized, and one MSM is running ExtremeWare XOS 10.1 or earlier, proceed to step 3. If the nodes are synchronized, proceed to step 3.

2 Use the synchronize command to ensure that the backup has the same software in flash as the master. NOTE
On the BlackDiamond 10K switch, both the backup and the master MSMs must be running ExtremeWare XOS 11.0 or later to use the synchronize command.

The synchronize command:


Reboots the backup MSM to prepare it for synchronizing with the master MSM Copies both the primary and secondary software images Copies both the primary and secondary configurations Reboots the backup MSM after replication is complete If both nodes are running ExtremeWare XOS 11.0 or later, use the run msm-failover command. If one node is running ExtremeWare XOS 10.1 or earlier, use the run msm-failover {force} command. By specifying force, failover occurs regardless of the version of software running on the MSMs.

3 Initiate failover from the master MSM to the backup MSM.


ExtremeWare XOS 11.3 Concepts Guide

71

Managing the Switch

Replicating Data Between Nodes


ExtremeWare XOS replicates configuration and run-time information between the master MSM and the backup MSM so that the system can recover if the master fails. This method of replicating data is known as checkpointing. Checkpointing is the process of automatically copying the active state from the master to the backup, which allows for state recovery if the master fails. Replicating data consists of the following three steps: 1 Configuration synchronizationRelays current and saved configuration information from the master to the backup 2 Bulk checkpointEnsures that each individual application running on the system is synchronized with the backup 3 Dynamic checkpointCheckpoints any new state changes from the master to the backup To monitor the checkpointing status, use the show checkpoint-data {<process>} command.

Relaying Configuration Information


To facilitate a failover from the master MSM to the backup MSM, the master transfers its active configuration to the backup. Relaying configuration information is the first level of checkpointing. During the initial switch boot-up, the masters configuration takes effect. During the initialization of a standby or backup MSM, the masters saved configuration is copied to local flash. After the configuration is saved, the master transfers the current active configuration to the backup. After the MSMs are synchronized, any configuration change you make to the master is relayed to the backup and incorporated into the backups configuration copy.

NOTE
To ensure that all of the configuration commands in the backups flash are updated, issue the save command after you make any changes.

If a failover occurs, the backup MSM continues to use the masters active configuration. If the backup determines that it does not have the masters active configuration because a run-time synchronization did not happen, the backup uses the configuration stored in its flash memory. Because the backup always uses the masters active configuration, the active configuration remains in affect regardless of the number of failovers.

NOTE
If you issue the reboot command before you save your configuration changes, the switch prompts you to save your changes. To keep your configuration changes, save them before you reboot the switch.

Bulk Checkpointing
Bulk checkpointing requires that the master and backup run-time states be synchronized. Since ExtremeWare XOS runs a series of applications, an application starts checkpointing only after all of the applications it depends on have transferred their run-time states to the backup MSM.

72

ExtremeWare XOS 11.3 Concepts Guide

Understanding System Redundancy with Dual MSMs InstalledModular Switches Only After one application completes bulk checkpointing, the next application proceeds with its bulk checkpointing. To monitor the checkpointing status, use the show checkpoint-data {<process>} command. To view the status of bulk checkpointing and see if the backup MSM is synchronized with the master MSM, use the show switch {detail} command.

Dynamic Checkpointing
After an application transfers its saved state to the backup MSM, dynamic checkpointing requires that any new configuration information or state changes that occur on the master be immediately relayed to the backup. This ensures that the backup has the most up-to-date and accurate information.

Viewing Checkpoint Statistics


Use the following command to view and check the status of one or more processes being copied from the master to the backup MSM:
show checkpoint-data {<process>}

This command is also helpful in debugging synchronization problems that occur at run time. This command displays, in percentages, the amount of copying completed by each process and the traffic statistics between the process on both the master and the backup MSMs.

Viewing Node Status


ExtremeWare XOS allows you to view node statistical information. Each node (MSM) installed in your system is self-sufficient and runs the ExtremeWare XOS management applications. By reviewing this output, you can see the general health of the system along with other node parameters. To view node status, use the following command:
show node {detail}

Table 10 lists the node status collected by the switch.

Table 10: Node states


Node State BACKUP DOWN Description In the backup state, this node becomes the master node if the master fails or enters the DOWN state. The backup node also receives the checkpoint state data from the master. In the down state, the node is not available to participate in leader election. The node enters this state during any user action, other than a failure, that makes the node unavailable for management. Examples of user actions are: Upgrading the software Rebooting the system using the reboot command Initiating an MSM failover using the run msm-failover command Synchronizing the MSMs software and configuration in non-volatile storage using the synchronize command

ExtremeWare XOS 11.3 Concepts Guide

73

Managing the Switch

Table 10: Node states (Continued)


Node State FAIL INIT Description In the fail state, the node has failed and needs to be restarted or repaired. The node reaches this state if the system has a hardware or software failure. In the initial state, the node is being initialized. A node stays in this state when it is coming up and remains in this state until it has been fully initialized. Being fully initialized means that all of the hardware has been initialized correctly and there are no diagnostic faults. In the master state, the node is responsible for all switch management functions. In the standby state, leader election occursthe master and backup nodes are elected. The priority of the node is only significant in the standby state.

MASTER STANDBY

Understanding Hitless Failover SupportModular Switches Only


As described in the section, Understanding System Redundancy with Dual MSMs InstalledModular Switches Only on page 70, if you install two MSMs in the chassis, one assumes the role of master (primary) and the other assumes the role of backup. The master MSM provides all of the switch management functions including bringing up and programming the I/O modules, running the bridging and routing protocols, and configuring the switch. The master MSM also synchronizes the backup MSM in case it needs to take over the management functions if the master MSM fails. The configuration is one of the most important pieces of information checkpointed to the backup MSM. Each component of the system needs to checkpoint whatever runtime data is necessary to allow the backup MSM to take over as the master MSM if a failover occurs, including the protocols and the hardware dependent layers. For more information about checkpointing data and relaying configuration information, see Replicating Data Between Nodes on page 72. Not all protocols support hitless failover; see Table 11 for a detailed list of protocols and their support. Layer 3 forwarding tables are maintained for pre-existing flows, but subsequent behavior depends on the routing protocols used. Static layer 3 configurations and routes are hitless. You must configure OSPF graceful restart for OSPF routes to be maintained. See Chapter 27, OSPF for more information. For routing protocols that do not support hitless failover, the new master MSM removes and re-adds the routes.

Protocol Support for Hitless Failover


Table 11 summarizes the protocol support for hitless failover. Unless otherwise noted, the behavior is the same for all modular switches. If a protocol indicates support for hitless failover, additional information is also available in that particular chapter. For example, for information about network login support of hitless failover, see Chapter 17, Network Login.

74

ExtremeWare XOS 11.3 Concepts Guide

Understanding Hitless Failover SupportModular Switches Only

Table 11: Protocol support for hitless failover


Protocol Spanning Tree Protocol (STP) Behavior STP supports hitless failover including catastrophic failure of the MSM without interruption. There should be no discernible network event external to the box. The protocol runs in lock step on both MSMs and the backup MSM is a hot spare that can take over at any time with no impact on the network. Master Mode If the master MSM state is Complete, the secondary port is blocking, and the backup MSM is in the Init state. The backup also blocks the secondary port. If the master fails over, the backup transitions from the Init state to the Complete state. No change in blocking occurs and there should not be any data loss. If the master MSM state is Failed, the secondary port is forwarding. The backup MSM enters the Init state. If the master fails over, the backup sends its continuous "Query Link Status PDU" every 3 seconds. Within these 3 seconds, the backup receives the Link Down PDU. It then sends a message to the lower layers to flush the FDB, and sets the secondary port to forwarding. If the master fails over, there will be a slight hit to traffic due to FDB being flushed. EAPS Continued Transit Mode If the master MSM state is LinksUp, both ports are forwarding. The backup MSM is also in the LinksUp state with both ports set to forwarding. If the master fails over, there is no change in backup's state. There should be no data loss. If the master MSM state is LinksDown, one or both ports are not forwarding traffic. The backup MSM is also in the LinksDown state with the same ports set to forwarding/blocking. If the master fails over, there is no change in the backups state. There should be no data loss. If the backup MSM state is Preforwarding, and the master MSM is in the LinksUp state, the backup receives a Health-PDU within 1 second and learns that the ring is complete. The backup sends a message to the lower layer to flush the FDB and sets the port to the forwarding state. If the master fails over, there will be slight hit to traffic due to FDB being flushed. EAPS Continued EAPS Shared Ports, Controller Mode If the master MSM state is Ready, the backup MSM is also in the Ready state. If the master fails over, there is no state change for the backup. There should be no data loss. If the master MSM state is Blocking, the backup MSM is also in the Blocking state. If no other link goes down, the backup blocks the same ports as the master. If the master fails over, there is no change in the backups state. There should be no data loss. However, if some segment's link is down, the backup may not know about it until it becomes the master. The backup sends a message to the lower layer to unblock the port and flush the FDB. In this case, there could be a slight hit to traffic due to FDB being flushed. In the Blocking state, there is a rare corner case situation where breaking two links and healing one of them might cause the "Active Open" port to no longer be the smallest port. The backup MSM does not know about this because of the sequence of breaking and healing. In this case, the backups behavior is unpredictable. In the Blocking state and the Root Blocker state, the backup MSM does not know about the Root Blocker state. The backup learns about the Root Blocker state only after becoming the master MSM (within 1 second). At that point the new master flushes the FDB and block segments. If the primary fails over, there is a slight hit to traffic due to the FDB being flushed. No No Hitless Yes

Ethernet Automatic Protection Switching (EAPS)

No

ExtremeWare XOS 11.3 Concepts Guide

75

Managing the Switch

Table 11: Protocol support for hitless failover (Continued)


Protocol EAPS Continued Behavior EAPS Shared Ports, Partner Mode Since the Partner node does not actively block traffic, whether the state is Ready or Blocking, it does not make any difference if the master MSM fails over. There should be no data loss. However, if the Partner is in the Blocking state, and it needs to advertise blocking-ids in a "Root Blocker" situation, it could take a couple of seconds to relearn the neighbors states and to advertise the correct information. Extreme Standby Router Protocol (ESRP) If MSM failover occurs on the ESRP MASTER switch, it sends a hello packet with the HOLD bit set. On receiving this packet, the ESRP SLAVE switch freezes all further state transitions. The MASTER switch keeps sending hellos with the HOLD bit set on every hello interval. When the MASTER is done with its MSM failover, it sends another hello with the HOLD bit reset. The SLAVE switch resumes normal processing. (If no packet is received with HOLD bit reset, the SLAVE timeouts after a certain time interval and resumes normal processing). MSM failover on the ESRP SLAVE switch is of no importance because it is the SLAVE switch. Virtual Router Redundancy Protocol (VRRP) Extreme Discovery Protocol (EDP) There is a brief interruption of traffic flow as the VRRP protocol re-establishes the correct state. With the default configuration settings, the worst-case interruption is 3 seconds. EDP does not checkpoint protocol data units (PDUs) or states, so the backup MSM does not have the neighbors information. If the backup MSM becomes the master MSM, and starts receiving PDUs, the new master learns about its neighbors. After a failover, all hardware and software caches are cleared and learning from the hardware is restarted. This causes a traffic interruption since it is the same as if the switch rebooted for all Layer 3 multicast traffic. If you use ELRP as a standalone tool, hitless failover support is not needed since the you initiate the loop detection. If you use ELRP in conjunction with ESRP, ELRP does not interfere with the hitless failover support provided by ESRP. Although there is no hitless failover support in ELRP itself, ELRP does not affect the network behavior if a failover occurs. Link Layer Discovery Protocol (LLDP) Since LLDP is more of a tool than a protocol, there is no hitless failover support. LLDP is similar to EDP, but there is also a MIB interface to query the information learned. After a failover, it takes 30 seconds or greater before the MIB database is fully populated again. If the Backup MSM becomes the primary MSM, it starts receiving PDUs, which causes the aggregators membership to change while the protocol converges. This causes a disruption to traffic but should settle within 6 seconds. RIP does not support graceful restart, so the route manager deletes all RIP routes 1 second after the failover occurs. This results in a traffic interruption as well as an increase in control traffic as RIP re-establishes its database. RIPng does not support graceful restart, so the route manager deletes all RIPng routes 1 second after the failover occurs. This results in a traffic interruption. In addition, after RIPng comes up on the new primary MSM, it relearns the routes from its neighbors. This causes an increase in control traffic onto the network. No No Yes Hitless No

No

Protocol Independent Multicast (PIM) Extreme Loop Recovery Protocol (ELRP)

No

No

Link Aggregation Control Protocol (LACP) Routing Information Protocol (RIP)

No

No

Routing Information Protocol next generation (RIPng)

No

76

ExtremeWare XOS 11.3 Concepts Guide

Understanding Hitless Failover SupportModular Switches Only

Table 11: Protocol support for hitless failover (Continued)


Protocol Open Shortest Path First (OSPF) Behavior If you configure OSPF graceful restart, there is no traffic interruption. However, after OSPF comes up after restart, OSPF re-establishes sessions with its neighbors and relearns Link State Advertisements (LSAs) from all of the neighbors. This causes an increase in control traffic onto the network. If you do not configure graceful restart, the route manager deletes all OSPF routes 1 second after the failover occurs, which results in a traffic interruption in addition to the increased control traffic. Open Shortest Path First v3 (OSPFv3) OSPFv3 does not support graceful restart, so the route manager deletes all OSPFv3 routes 1 second after the failover occurs. This results in a traffic interruption. In addition, after OSPFv3 comes up on the new primary MSM, it relearns the routes from its neighbors. This causes an increase in control traffic onto the network. Border Gateway Protocol (BGP) BGP does not support graceful restart, so the route manager deletes all BGP routes 1 second after the failover occurs. This results in a traffic interruption. In addition, after BGP comes up on the new primary MSM, it re-establish sessions with its neighbors and relearns routes from all of them. This causes an increase in control traffic onto the network. Power over Ethernet (PoE) The PoE configuration is checkpointed to the backup MSM. This ensures that if the backup takes over, all ports currently powered stay powered after the failover and the configured power policies are still in place. This behavior is applicable only on the BlackDiamond 8800 family of switches. Network Login 802.1x Authentication Authenticated clients continue to remain authenticated after failover. However, 1 second after failover, all authenticated clients are forced to re-authenticate themselves. Information about unauthenticated clients is not checkpointed across MSMs so any such clients that were in the process of being authenticated at the instant of failover must go through the authentication process again from the beginning after failover. Network Login Continued MAC-Based Authentication Authenticated clients continue to remain authenticated after failover so the failover is transparent to them. Information about unauthenticated clients is not checkpointed across MSMs so any such clients that were in the process of being authenticated at the instant of failover must go through the authentication process again from the beginning after failover. In the case of MAC-Based authentication, the authentication process is very short with only a single packet being sent to the switch so it is expected to be transparent to the client stations. Network Login Continued Web-Based Authentication Web-based Netlogin users continue to be authenticated after a failover. Yes Yes Yes Yes No No Hitless Yes

Platform Support for Hitless Failover


Table 12 lists when each modular platform introduced support for hitless failover for a specific protocol. As described in Table 11, not all protocols support hitless failover.

ExtremeWare XOS 11.3 Concepts Guide

77

Managing the Switch

Table 12: Platform support for hitless failover


Platform BlackDiamond 10K BlackDiamond 10K BlackDiamond 10K BlackDiamond 10K BlackDiamond 8800 family BlackDiamond 8800 family BlackDiamond 8800 family BlackDiamond 8800 family BlackDiamond 8800 family Protocol ESRP OSPF graceful restart Network login STP ESRP Network login OSPF graceful restart PoE STP ExtremeWare XOS Version ExtremeWare XOS 11.0 ExtremeWare XOS 11.3 ExtremeWare XOS 11.3 ExtremeWare XOS 11.0 ExtremeWare XOS 11.3 ExtremeWare XOS 11.3 ExtremeWare XOS 11.3 ExtremeWare XOS 11.3 ExtremeWare XOS 11.3

Hitless Failover Caveats


This section describes the caveats for hitless failover. Please check the latest version of the ExtremeWare XOS release notes for additional information.

Caveats for All Modular Switches


The following is a summary of hitless failover caveats for all modular switches:

A brief traffic interruption (less than 1/2 of a second) can occur when the failover happens due to reprogramming of the I/O modules to bypass the original primary MSMs switch chips. There is a 50% reduction in backplane bandwidth during a failover.

Caveats for the BlackDiamond 8800 Family of Switches


The following is a summary of hitless failover caveat s for only the BlackDiamond 8800 family of switches:

MSM I/O ports on the original primary MSM are not available during the failover and this MSM I/O subsection is power cycled. It takes about 2 minutes for these MSM I/O ports to be able to pass traffic again. I/O modules not yet in the Operational state are powered off and the card state machine is restarted to bring them to the Operational state. This results in a delay in the I/O module becoming Operational.

Understanding Power Supply Management


This section describes how ExtremeWare XOS manages power consumption on the switch and contains the following topics:

Using Power SuppliesModular Switches Only on page 79 Using Power SuppliesSummit X450 Switch Only on page 81 Displaying Power Supply Information on page 82

78

ExtremeWare XOS 11.3 Concepts Guide

Understanding Power Supply Management

Using Power SuppliesModular Switches Only


ExtremeWare XOS monitors and manages power consumption on the switch by periodically checking the power supply units (PSUs) and testing them for failures. To determine the health of the PSU, ExtremeWare XOS checks the voltage, current, and temperature of the PSU. The power management capability of ExtremeWare XOS:

Protects the system from overload conditions Monitors all installed PSUs, even installed PSUs that are disabled Enables and disables PSUs as required Powers up or down I/O modules based on available power and required power resources Logs power resource changes, including power budget, total available power, redundancy, and so on Detects and isolates faulty PSUs

The switch includes two power supply controllers that collect data from the installed PSUs and report the results to the MSM modules. When you first power on the switch, the power supply controllers enable a PSU. As part of the power management function, the power controller disables the PSU if an unsafe condition arises. For more information about the power supply controller, see the Extreme Networks Consolidated XOS Hardware Installation Guide. If you have a BlackDiamond 8800 Power over Ethernet (PoE) G48P module installed in any of the BlackDiamond 8800 family of switches, there are specific power budget requirements and configurations associated with PoE that are not described in this section. For more detailed information about PoE, see Chapter 7, "Power Over Ethernet." This section describes the following power management topics:

Initial System Boot-Up on page 79 Power Redundancy on page 80 Power Management Guidelines on page 80 Overriding Automatic Power Supply Management on page 81

Initial System Boot-Up


When ExtremeWare XOS boots up, it reads and analyzes the installed I/O modules. ExtremeWare XOS considers the I/O modules for power up from the lowest numbered slot to the highest numbered slot, based on their power requirements and the available system power. If the system does not have enough power, some I/O modules are not powered up. For example, ExtremeWare XOS:

Collects information about the PSUs installed to determine how many are running and how much power each can supply. Checks for PSU failures. Calculates the number of I/O modules to power up based on the available power budget and the power requirements of each I/O module, including PoE requirements for the BlackDiamond 8800 PoE I/O module. Reserves the amount of power required to power up a second MSM if only one MSM is installed. Reserves the amount of power required to power all fans and chassis components. Calculates the current power surplus or shortfall. Logs and sends SNMP traps for transitions in the overall system power status, including whether the available amount of power is:

ExtremeWare XOS 11.3 Concepts Guide

79

Managing the Switch

Redundant or N+1Power from a single PSU can be lost and no I/O modules are powered down. Sufficient, but not redundantPower from a single PSU is lost, and one or more I/O modules are powered down. InsufficientOne or more modules are not powered up due to a shortfall of available power.

By reading the PSU information, ExtremeWare XOS determines the power status and the total amount of power available to the system. The total power available determines which I/O modules can be powered up.

Power Redundancy
In simple terms, power redundancy (N+1) protects the system from shutting down. With redundancy, if the output of one PSU is lost for any reason, the system remains fully powered. In this scenario, N is the minimum number of power supplies needed to keep the system fully powered and the system has N+1 PSUs powered. If the system power status is not redundant, the removal of one PSU, the loss of power to one PSU, or a degradation of input voltage results in insufficient power to keep all of the I/O modules powered up. If there is not enough power, ExtremeWare XOS powers down the I/O modules from the highest numbered slot to the lowest numbered slot until the switch has enough power to continue operation. If you install or provide power to a new PSU, I/O modules powered down due to earlier insufficient power are considered for power up from the lowest slot number to the highest slot number, based on the I/O modules power requirements. Whenever the system experiences a change in power redundancy, including a change in the total available power, degraded input voltage, or a return to redundant power, the switch sends messages to the syslog.

Power Management Guidelines


The following list describes some key issues to remember when identifying your power needs and installing PSUs:

If you disable a slot, the I/O module installed in that slot is always powered down regardless of the number of PSUs installed. If a switch has PSUs with a mix of both 220V AC and 110V AC inputs, ExtremeWare XOS maximizes system power by automatically taking one of two possible actions:

If all PSUs are enabled then all PSUs must be budgeted at 110V AC to prevent overload of PSUs with 110V AC inputs. If the PSUs with 110V AC inputs are disabled, then the PSUs with 220V AC inputs can be budgeted with a higher output per PSU.

OR

ExtremeWare XOS computes the total available power using both methods and automatically uses the PSU configuration that provides the greatest amount of power to the switch. Table 13 lists combinations where ExtremeWare XOS maximizes system power by disabling the PSUs with 110V AC inputs.

80

ExtremeWare XOS 11.3 Concepts Guide

Understanding Power Supply Management

Table 13: PSU combinations where 110V PSUs are disabled


Number of PSUs with 220V AC Inputs 2 3 3 4 4 5 Number of PSUs with 110V AC Inputs 1 1 2 1 2 1

For all other combinations of 220V AC and 110V AC PSUs, ExtremeWare XOS maximizes system power by enabling all PSUs and budgeting each PSU at 110V AC. NOTE
If you are running ExtremeWare XOS 11.2 or 11.1 and mix PSUs with 110V and 220V AC inputs, the switch budgets all PSUs as if they have 110V AC inputs.

Overriding Automatic Power Supply Management


You can override automatic power supply management to enable a PSU with 110V AC inputs that ExtremeWare XOS disables if the need arises, such as for a planned maintenance of 220V AC circuits. If the combination of AC inputs represents one of those listed in Table 13, you can turn on a disabled PSU using the following command:
configure power supply <ps_num> on

NOTE
If you override automatic power supply management, you may reduce the available power and cause one or more I/O modules to power down.

To resume using automatic power supply management on a PSU, use the configure power supply <ps_num> auto command. The setting for each PSU is stored as part of the switch configuration. To display power supply status and power budget information use the show power and show power
budget commands.

Using Power SuppliesSummit X450 Switch Only


On the Summit X450 switch, ExtremeWare XOS reports when the PSU has power or has failed. The SummitX450 switch supports an internal power supply with a range of 90V to 240V AC power as well as an external redundant power supply. The Extreme Networks External Power System (EPS) allows you to add a redundant power supply to the Summit X450 switch to protect against a power supply failure. The EPS consists of a tray (EPS-T) that holds one or two EPS-160 power supplies. The EPS-160 provides 100V to 240V AC power. Each EPS-160 power supply provides one-to-one redundancy to an attached SummitX450 switch.

ExtremeWare XOS 11.3 Concepts Guide

81

Managing the Switch If you experience an internal PSU failure and do not have an external PSU installed, the switch powers down. If you experience a PSU failure and have an external PSU installed, the switch uses the external PSU to maintain power to the switch. For more information about the Summit X450 switch and the EPS, see the Extreme Networks Consolidated XOS Hardware Installation Guide.

Displaying Power Supply Information


To display the status of the currently installed power supplies, use the following command:
show power {<ps_num>} {detail}

On modular switches, the following commands provide additional power supply information. To view the system power status and the amount of available and required power, use the following command:
show power budget

To display the status of the currently installed power supply controllers, use the following command:
show power controller {<num>}

Using the Simple Network Management Protocol


Any network manager program running the Simple Network Management Protocol (SNMP) can manage the switch, provided the Management Information Base (MIB) is installed correctly on the management station. Each network manager program provides its own user interface to the management facilities. Please note, when using a network manager program to create a VLAN, Extreme Networks does not support the SNMP create and wait operation. To create a VLAN with SNMP, use the create and go operation. The following sections describe how to get started if you want to use an SNMP manager. It assumes you are already familiar with SNMP management. If not, refer to the following publication: The Simple Book by Marshall T. Rose ISBN 0-13-8121611-9 Published by Prentice Hall. This section covers the following SNMP topics:

Enabling and Disabling SNMPv1/v2c and SNMPv3 on page 83 Accessing Switch Agents on page 84 Supported MIBs on page 84 Configuring SNMPv1/v2c Settings on page 84 Displaying SNMP Settings on page 84 SNMPv3 on page 85

82

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Management Protocol


Message Processing on page 86 SNMPv3 Security on page 86 SNMPv3 MIB Access Control on page 89 SNMPv3 Notification on page 90

Enabling and Disabling SNMPv1/v2c and SNMPv3


ExtremeWare XOS can concurrently support SNMPv1/v2c and SNMPv3. The default is both types of SNMP enabled. Network managers can access the device with either SNMPv1/v2c methods or SNMPv3. To enable concurrent support, use the following command:
enable snmp access

To prevent any type of SNMP access, use the following command:


disable snmp access

To prevent access using SNMPv1/v2c methods and allow access using SNMPv3 methods only, use the following commands:
enable snmp access disable snmp access {snmp-v1v2c}

There is no way to configure the switch to simultaneously allow SNMPv1/v2c access and prevent SNMPv3 access. Most of the commands that support SNMPv1/v2c use the keyword snmp; most of the commands that support SNMPv3 use the keyword snmpv3. After a switch reboot, all slots must be in the "Operational" state before SNMP can manage and access the slots. To verify the current state of the slot, use the show slot command.

Understanding Safe Defaults Mode and SNMP


ExtremeWare XOS 11.2 introduces the concept of safe defaults mode. Safe defaults mode runs an interactive script that allows you to enable or disable SNMP, Telnet, and switch ports. When you set up your switch for the first time, you must connect to the console port to access the switch. After logging in to the switch, you enter safe defaults mode. Although SNMP, Telnet, and switch ports are enabled by default, the script prompts you to confirm those settings. If you choose to keep the default setting for SNMPthe default setting is enabledthe switch returns the following interactive script:
Since you have chosen less secure management methods, please remember to increase the security of your network by taking the following actions: * change your admin password * change your SNMP public and private strings * consider using SNMPv3 to secure network management traffic

For more detailed information about safe defaults mode, see Safe Defaults Setup Method on page 47.

ExtremeWare XOS 11.3 Concepts Guide

83

Managing the Switch

Accessing Switch Agents


To access the SNMP agent residing in the switch, at least one VLAN must have an assigned IP address. By default, SNMP access and SNMPv1/v2c traps are enabled. SNMP access and SNMP traps can be disabled and enabled independentlyyou can disable SNMP access but still allow SNMP traps to be sent, or vice versa.

Supported MIBs
In addition to private MIBs, the switch supports the standard MIBs listed in Appendix D.

Configuring SNMPv1/v2c Settings


The following SNMPv1/v2c parameters can be configured on the switch:

Authorized trap receiversAn authorized trap receiver can be one or more network management stations on your network. The switch sends SNMPv1/v2c traps to all configured trap receivers. You can specify a community string and UDP port individually for each trap receiver. All community strings must also be added to the switch using the configure snmp add community command. To configure a trap receiver on a switch, use the following command:
configure snmp add trapreceiver <ip_address> community [[hex <hex_community_name>] | <community_name>] {port <port_number>} {from <src_ip_address>} {mode <trap_mode> [enhanced | standard]}

You can delete a trap receiver using the configure snmp delete trapreceiver command. Entries in the trap receiver list can also be created, modified, and deleted using the RMON2 trapDestTable MIB table, as described in RFC 2021.

Community stringsThe community strings allow a simple method of authentication between the switch and the remote network manager. There are two types of community strings on the switch:

Read community strings provide read-only access to the switch. The default read-only community string is public. Read-write community strings provide read- and-write access to the switch. The default readwrite community string is private.

System contact (optional)The system contact is a text field that enables you to enter the name of the person(s) responsible for managing the switch. System name (optional)The system name enables you to enter a name that you have assigned to this switch. The default name is the model name of the switch (for example, BD-1.2). System location (optional)Using the system location field, you can enter the location of the switch.

Displaying SNMP Settings


To display the SNMP settings configured on the switch, use the following command:
show management

This command displays the following information:


Enable/disable state for Telnet and SNMP access Login statistics

84

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Management Protocol


Enable/disable state for idle timeouts Maximum number of CLI sessions

SNMP community strings SNMP trap receiver list SNMP trap receiver source IP address SNMP statistics counter Enable/disable state for Remote Monitoring (RMON)

SNMPv3
SNMPv3 is an enhanced standard for SNMP that improves the security and privacy of SNMP access to managed devices and provides sophisticated control of access to the device MIB. The prior standard versions of SNMP, SNMPv1 and SNMPv2c, provided no privacy and little security. The following six RFCs provide the foundation for the Extreme Networks implementation of SNMPv3:

RFC 2570, Introduction to version 3 of the Internet-standard Network Management Framework, provides an overview of SNMPv3. RFC 2571, An Architecture for Describing SNMP Management Frameworks, talks about SNMP architecture, especially the architecture for security and administration. RFC 2572, Message Processing and Dispatching for the Simple Network Management Protocol (SNMP), talks about the message processing models and dispatching that can be a part of an SNMP engine. RFC 2573, SNMPv3 Applications, talks about the different types of applications that can be associated with an SNMPv3 engine. RFC 2574, The User-Based Security Model for Version 3 of the Simple Network Management Protocol (SNMPv3), describes the User-Based Security Model (USM). RFC 2575, View-based Access Control Model (V ACM) for the Simple Network Management Protocol (SNMP), talks about VACM as a way to access the MIB.

The SNMPv3 standards for network management were primarily driven by the need for greater security and access control. The new standards use a modular design and model management information by cleanly defining a message processing (MP) subsystem, a security subsystem, and an access control subsystem. The MP subsystem helps identify the MP model to be used when processing a received Protocol Data Unit (PDU), which are the packets used by SNMP for communication. The MP layer helps in implementing a multilingual agent, so that various versions of SNMP can coexist simultaneously in the same network. The security subsystem features the use of various authentication and privacy protocols with various timeliness checking and engine clock synchronization schemes. SNMPv3 is designed to be secure against:

Modification of information, where an in-transit message is altered. Masquerades, where an unauthorized entity assumes the identity of an authorized entity. Message stream modification, where packets are delayed and/or replayed. Disclosure, where packet exchanges are sniffed (examined) and information is learned about the contents.

ExtremeWare XOS 11.3 Concepts Guide

85

Managing the Switch The access control subsystem provides the ability to configure whether access to a managed object in a local MIB is allowed for a remote principal. The access control scheme allows you to define access policies based on MIB views, groups, and multiple security levels. In addition, the SNMPv3 target and notification MIBs provide a more procedural approach for generating and filtering of notifications. SNMPv3 objects are stored in non-volatile memory unless specifically assigned to volatile storage. Objects defined as permanent cannot be deleted.

NOTE
In SNMPv3, many objects can be identified by a human-readable string or by a string of hexadecimal octets. In many commands, you can use either a character string, or a colon-separated string of hexadecimal octets to specify objects. To indicate hexadecimal octets, use the keyword hex in the command.

Message Processing
A particular network manager may require messages that conform to a particular version of SNMP. The choice of the SNMPv1, SNMPv2c, or SNMPv3 MP model can be configured for each network manager as its target address is configured. The selection of the MP model is configured with the mp-model keyword in the following command:
configure snmpv3 add target-params [[hex <hex_param_name>] | <param_name>] user [[hex <hex_user_name>] | <user_name>] mp-model [snmpv1 | snmpv2c | snmpv3] sec-model [snmpv1 | snmpv2c | usm] {sec-level [noauth | authnopriv | priv]} {volatile}

SNMPv3 Security
In SNMPv3 the User-Based Security Model (USM) for SNMP was introduced. USM deals with security related aspects like authentication, encryption of SNMP messages, and defining users and their various access security levels. This standard also encompasses protection against message delay and message replay.

USM Timeliness Mechanisms


An Extreme Networks switch has one SNMPv3 engine, identified by its snmpEngineID. The first four octets are fixed to 80:00:07:7C, which represents the Extreme Networks vendor ID. By default, the additional octets for the snmpEngineID are generated from the device MAC address. Every SNMPv3 engine necessarily maintains two objects: SNMPEngineBoots, which is the number of reboots the agent has experienced and SNMPEngineTime, which is the local time since the engine reboot. The engine has a local copy of these objects and the latestReceivedEngineTime for every authoritative engine it wants to communicate with. Comparing these objects with the values received in messages and then applying certain rules to decide upon the message validity accomplish protection against message delay or message replay. In a chassis, the snmpEngineID is generated using the MAC address of the MSM with which the switch boots first. The snmpEngineID can be configured from the command line, but once the snmpEngineID is changed, default users will be reverted back to their original passwords/keys, and non-default users will be reset

86

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Management Protocol to the security level of no authorization, no privacy. To set the snmpEngineID, use the following command:
configure snmpv3 engine-id <hex_engine_id>

SNMPEngineBoots can also be configured from the command line. SNMPEngineBoots can be set to any desired value but will latch on its maximum, 2147483647. To set the SNMPEngineBoots, use the following command:
configure snmpv3 engine-boots <(1-2147483647)>

Users, Groups, and Security


SNMPv3 controls access and security using the concepts of users, groups, security models, and security levels. Users. Users are created by specifying a user name. Depending on whether the user will be using authentication and/or privacy, you would also specify an authentication protocol (MD5 or SHA) with password or key, and/or privacy (DES) password or key. To create a user, use the following command:
configure snmpv3 add user [[hex <hex_user_name>] | <user_name>] {authentication [md5 | sha] [hex <hex_auth_password> | <auth_password>]} {privacy [hex <hex_priv_password> | <priv_password>]} {volatile}

A number of default, permanent users are initially available. The default user names are: admin, initial, initialmd5, initialsha, initialmd5Priv, initialshaPriv. The default password for admin is password. For the other default users, the default password is the user name. To display information about a user, or all users, use the following command:
show snmpv3 user {[[hex <hex_user_name>] | <user_name>]}

To delete a user, use the following command:


configure snmpv3 delete user [all-non-defaults | [[hex <hex_user_name>] | <user_name>]]

NOTE
The SNMPv3 specifications describe the concept of a security name. In the ExtremeWare XOS implementation, the user name and security name are identical. In this manual, both terms are used to refer to the same thing.

Groups. Groups are used to manage access for the MIB. You use groups to define the security model, the security level, and the portion of the MIB that members of the group can read or write. To underscore the access function of groups, groups are defined using the following command:
configure snmpv3 add access [[hex <hex_group_name>] | <group_name>] {sec-model [snmpv1 | snmpv2c | usm]} {sec-level [noauth | authnopriv | priv]} {read-view [[hex <hex_read_view_name>] | <read_view_name>]} {write-view [[hex <hex_write_view_name>]] | <write_view_name>]} {notify-view [[hex <hex_notify_view_name]] | <notify_view_name>]} {volatile}

The security model and security level are discussed in Security Models and Levels on page 88. The view names associated with a group define a subset of the MIB (subtree) that can be accessed by members of the group. The read view defines the subtree that can be read, write view defines the

ExtremeWare XOS 11.3 Concepts Guide

87

Managing the Switch subtree that can be written to, and notify view defines the subtree that notifications can originate from. MIB views are discussed in SNMPv3 MIB Access Control on page 89. A number of default (permanent) groups are already defined. These groups are: admin, initial, v1v2c_ro, v1v2c_rw. To display information about the access configuration of a group or all groups, use the following command:
show snmpv3 access {[[hex <hex_group_name>] | <group_name>]}

Users are associated with groups using the following command:


configure snmpv3 add group [[hex <hex_group_name>] | <group_name>] user [[hex <hex_user_name>] | <user_name>] {sec-model [snmpv1| snmpv2c | usm]} {volatile}

To show which users are associated with a group, use the following command:
show snmpv3 group {[[hex <hex_group_name>] | <group_name>] {user [[hex <hex_user_name>] | <user_name>]}}

To delete a group, use the following command:


configure snmpv3 delete access [all-non-defaults | {[[hex <hex_group_name>] | <group_name>] {sec-model [snmpv1 | snmpv2c | usm] sec-level [noauth | authnopriv | priv]}}]

When you delete a group, you do not remove the association between the group and users of the group. To delete the association between a user and a group, use the following command:
configure snmpv3 delete group {[[hex <hex_group_name>] | <group_name>]} user [all-nondefaults | {[[hex <hex_user_name>] | <user_name>] {sec-model [snmpv1|snmpv2c|usm]}}]

Security Models and Levels. For compatibility, SNMPv3 supports three security models:

SNMPv1no security SNMPv2ccommunity strings based security SNMPv3USM security

The default is USM. You can select the security model based on the network manager in your network. The three security levels supported by USM are:

noAuthnoPrivNo authentication, no privacy. This is the case with existing SNMPv1/v2c agents. AuthnoPrivAuthentication, no privacy. Messages are tested only for authentication. AuthPrivAuthentication, privacy. This represents the highest level of security and requires every message exchange to pass the authentication and encryption tests.

When a user is created, an authentication method is selected, and the authentication and privacy passwords or keys are entered. When MD5 authentication is specified, HMAC-MD5-96 is used to achieve authentication with a 16-octet key, which generates an 128-bit authorization code. This authorization code is inserted in msgAuthenticationParameters field of SNMPv3 PDUs when the security level is specified as either AuthnoPriv or AuthPriv. Specifying SHA authentication uses the HMAC-SHA protocol with a 20-octet key for authentication.

88

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Management Protocol For privacy, a 16-octet key is provided as input to DES-CBS encryption protocol, which generates an encrypted PDU to be transmitted. DES uses bytes 1-7 to make a 56 bit key. This key (encrypted itself) is placed in msgPrivacyParameters of SNMPv3 PDUs when the security level is specified as AuthPriv.

SNMPv3 MIB Access Control


SNMPv3 provides a fine-grained mechanism for defining which parts of the MIB can be accessed. This is referred to as the View-Based Access Control Model (VACM). MIB views represent the basic building blocks of VACM. They are used to define a subset of the information in the MIB. Access to read, to write, and to generate notifications is based on the relationship between a MIB view and an access group. The users of the access group can then read, write, or receive notifications from the part of the MIB defined in the MIB view as configured in the access group. A view name, a MIB subtree/mask, and an inclusion or exclusion define every MIB view. For example, there is a System group defined under the MIB-2 tree. The Object Identifier (OID) for MIB-2 is 1.3.6.1.2, and the System group is defined as MIB-2.1.1, or directly as 1.3.6.1.2.1.1. To define a MIB view which includes only the System group, use the following subtree/mask combination:
1.3.6.1.2.1.1/1.1.1.1.1.1.1.0

The mask can also be expressed in hex notation (this is used for the ExtremeWare XOS CLI):
1.3.6.1.2.1.1/fe

To define a view that includes the entire MIB-2, use the following subtree/mask:
1.3.6.1.2.1.1/1.1.1.1.1.0.0.0

which, in the CLI, is:


1.3.6.1.2.1.1/f8

When you create the MIB view, you can choose to include the MIB subtree/mask or to exclude the MIB subtree/mask. To create a MIB view, use the following command:
configure snmpv3 add mib-view [[hex <hex_view_name>] | <view_name>] subtree <object_identifier> {/<subtree_mask>} {type [included | excluded]} {volatile}

After the view has been created, you can repeatedly use the configure snmpv3 add mib-view command to include and/or exclude MIB subtree/mask combinations to precisely define the items you want to control access to. In addition to the user-created MIB views, there are three default views. These default views are of storage type permanent and cannot be deleted, but they can be modified. The default views are: defaultUserView, defaultAdminView, and defaultNotifyView. To show MIB views, use the following command:
show snmpv3 mib-view {[[hex <hex_view_name>] | <view_name>] {subtree <object_identifier>}}

ExtremeWare XOS 11.3 Concepts Guide

89

Managing the Switch To delete a MIB view, use the following command:
configure snmpv3 delete mib-view [all-non-defaults | {[[hex <hex_view_name>] | <view_name>] {subtree <object_identifier>}}]

MIB views that are used by security groups cannot be deleted.

SNMPv3 Notification
SNMPv3 can use either SNMPv1 traps or SNMPv2c notifications to send information from an agent to the network manager. The terms trap and notification are used interchangeably in this context. Notifications are messages sent from an agent to the network manager, typically in response to some state change on the agent system. With SNMPv3, you can define precisely which traps you want sent, to which receiver by defining filter profiles to use for the notification receivers. To configure notifications, you configure a target address for the target that receives the notification, a target parameters name, and a list of notification tags. The target parameters specify the security and MP models to use for the notifications to the target. The target parameters name also points to the filter profile used to filter the notifications. Finally, the notification tags are added to a notification table so that any target addresses using that tag will receive notifications.

Target Addresses
A target address is similar to the earlier concept of a trap receiver. To configure a target address, use the following command:
configure snmpv3 add target-addr [[hex <hex_addr_name] | <addr_name>] param [[hex <hex_param_name] | <param_name>] ipaddress [[<ip_address> {<netmask>}] | <ip_address>] {transport-port <port_number> {from <src_ip_address>} {tag-list <tag_list>} {volatile}

In configuring the target address you supply an address name that identifies the target address, a parameters name that indicates the MP model and security for the messages sent to that target address, and the IP address and port for the receiver. The parameters name also is used to indicate the filter profile used for notifications. The target parameters is discussed in Target Parameters next. The from option sets the source IP address in the notification packets. The tag-list option allows you to associate a list of tags with the target address. The tag defaultNotify is set by default. Tags are discussed in the section Notification Tags. To display target addresses, use the following command:
show snmpv3 target-addr {[[hex <hex_addr_name>] | <addr_name>]}

To delete a single target address or all target addresses, use the following command:
configure snmpv3 delete target-addr [{[[hex <hex_addr_name>] | <addr_name>]} | all]

Target Parameters
Target parameters specify the MP model, security model, security level, and user name (security name) used for messages sent to the target address. See Message Processing on page 86 and Users, Groups, and Security on page 87 for more details on these topics. In addition, the target parameter name used for a target address points to a filter profile used to filter notifications. When you specify a filter profile,

90

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Management Protocol you associate it with a parameter name, so you must create different target parameter names if you use different filters for different target addresses. To create a target parameter name and to set the message processing and security settings associated with it, use the following command:
configure snmpv3 add target-params [[hex <hex_param_name>] | <param_name>] user [[hex <hex_user_name>] | <user_name>] mp-model [snmpv1 | snmpv2c | snmpv3] sec-model [snmpv1 | snmpv2c | usm] {sec-level [noauth | authnopriv | priv]} {volatile}

To display the options associated with a target parameters name or all target parameters names, use the following command:
show snmpv3 target-params {[[hex <hex_target_params>] | <target_params>]}

To delete one or all the target parameters, use the following command:
configure snmpv3 delete target-params [{[[hex <hex_param_name>] | <param_name>]} | all]

Filter Profiles and Filters


A filter profile is a collection of filters that specifies which notifications should be sent to a target address. A filter is defined by a MIB subtree and mask and by whether that subtree and mask is included or excluded from notification. When you create a filter profile, you are associating only a filter profile name with a target parameter name. The filters that make up the profile are created and associated with the profile using a different command. To create a filter profile, use the following command:
configure snmpv3 add filter-profile [[hex <hex_profile_name>] | <profile_name>] param [[hex <hex_param_name>]] | <param_name>] {volatile}

After the profile name has been created, you associate filters with it using the following command:
configure snmpv3 add filter [[hex <hex_profile_name>] | <profile_name>] subtree <object_identifier> {/<subtree_mask>} type [included | excluded] {volatile}

The MIB subtree and mask are discussed in SNMPv3 MIB Access Control on page 89, as filters are closely related to MIB views. You can add filters together, including and excluding different subtrees of the MIB until your filter meets your needs. To display the association between parameter names and filter profiles, use the following command:
show snmpv3 filter-profile {[[hex <hex_profile_name>] | <profile_name>]} {param [[hex <hex_param_name>] | <param_name>]}

To display the filters that belong a filter profile, use the following command:
show snmpv3 filter {[[hex <hex_profile_name>] | <profile_name>] {{subtree} <object_identifier>}

To delete a filter or all filters from a filter profile, use the following command:
configure snmpv3 delete filter [all | [[hex <hex_profile_name>] | <profile_name>] {subtree <object_identifier>}]]

ExtremeWare XOS 11.3 Concepts Guide

91

Managing the Switch To remove the association of a filter profile or all filter profiles with a parameter name, use the following command:
configure snmpv3 delete filter-profile [all |[[hex <hex_profile_name>] | <profile_name>] {param [[hex <hex_param_name>] | <param_name>}]]

Notification Tags
When you create a target address, either you associate a list of notification tags with the target or by default, the defaultNotify tag is associated with the target. When the system generates notifications, only those targets associated with tags currently in the standard MIB table, called snmpNotifyTable, are notified. To add an entry to the table, use the following command:
configure snmpv3 add notify [[hex <hex_notify_name>] | <notify_name>] tag [[hex <hex_tag>] | <tag>] {volatile}

Any targets associated with tags in the snmpNotifyTable are notified, based on the filter profile associated with the target. To display the notifications that are set, use the following command:
show snmpv3 notify {[[hex <hex_notify_name>] | <notify_name>]}

To delete an entry from the snmpNotifyTable, use the following command:


configure snmpv3 delete notify [{[[hex <hex_notify_name>] | <notify_name>]} | all-nondefaults]

You cannot delete the default entry from the table, so any targets configured with the defaultNotify tag will always receive notifications consistent with any filter profile specified.

Configuring Notifications
Because the target parameters name points to a number of objects used for notifications, configure the target parameter name entry first. You can then configure the target address, filter profiles and filters, and any necessary notification tags.

Using the Simple Network Time Protocol


ExtremeWare XOS supports the client portion of the Simple Network Time Protocol (SNTP) Version 3 based on RFC1769. SNTP can be used by the switch to update and synchronize its internal clock from a Network Time Protocol (NTP) server. After SNTP has been enabled, the switch sends out a periodic query to the indicated NTP server, or the switch listens to broadcast NTP updates. In addition, the switch supports the configured setting for Greenwich Mean time (GMT) offset and the use of Daylight Saving Time.

92

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Time Protocol

Configuring and Using SNTP


To use SNTP, follow these steps: 1 Identify the host(s) that are configured as NTP server(s). Additionally, identify the preferred method for obtaining NTP updates. The options are for the NTP server to send out broadcasts or for switches using NTP to query the NTP server(s) directly. A combination of both methods is possible. You must identify the method that should be used for the switch being configured. 2 Configure the Greenwich Mean Time (GMT) offset and Daylight Saving Time preference. The command syntax to configure GMT offset and usage of Daylight Saving Time is as follows:
configure timezone {name <std_timezone_ID>} <GMT_offset> {autodst {name <dst_timezone_ID>} {<dst_offset>} {begins [every <floatingday> | on <absoluteday>] {at <time_of_day_hour> <time_of_day_minutes>} {ends [every <floatingday> | on <absoluteday>] {at <time_of_day_hour> <time_of_day_minutes>}}}

By default, Daylight Saving Time is assumed to begin on the first Sunday in April at 2:00 AM, and end the last Sunday in October at 2:00 AM and to be offset from standard time by one hour. If this is the case in your time zone, you can set up automatic daylight savings adjustment with the command:
configure timezone <GMT_offset> autodst

If your time zone uses starting and ending dates and times that differ from the default, you can specify the starting and ending date and time in terms of a floating day, as follows:
configure timezone name MET 60 autodst name MDT begins every last sunday march at 1 30 ends every last sunday october at 1 30

You can also specify a specific date and time, as shown in the following command:
configure timezone name NZST 720 autodst name NZDT 60 begins every first sunday october at 2 00 ends on 3 16 2004 at 2 00

The optional time zone IDs are used to identify the time zone in display commands such as show
switch {detail}.

Table 14 describes the command options in detail.

Table 14: Time zone configuration command options


GMT_offset std-timezone-ID autodst dst-timezone-ID dst_offset floating_day Specifies a Greenwich Mean Time (GMT) offset, in + or - minutes. Specifies an optional name for this timezone specification. May be up to six characters in length. The default is an empty string. Enables automatic Daylight Savings Time. Specifies an optional name for this Daylight Savings Time specification. May be up to six characters in length. The default is an empty string. Specifies an offset from standard time, in minutes. Value is in the range of 1 to 60. Default is 60 minutes. Specifies the day, week, and month of the year to begin or end Daylight Savings Time each year. Format is: <week> <day> <month> where: <week> is specified as [first | second | third | fourth | last] <day> is specified as [sunday | monday | tuesday | wednesday | thursday | friday | saturday] <month> is specified as [january | february | march | april | may | june | july | august | september | october | november | december] Default for beginning is first sunday april; default for ending is last sunday october.

ExtremeWare XOS 11.3 Concepts Guide

93

Managing the Switch

Table 14: Time zone configuration command options (Continued)


absolute_day Specifies a specific day of a specific year on which to begin or end DST. Format is: <month> <day> <year> where: <month> is specified as 1-12 <day> is specified as 1-31 <year> is specified as 1970 - 2035 The year must be the same for the begin and end dates. time_of_day_hour time_of_day_minut es noautodst Specifies the time of day to begin or end Daylight Savings Time. May be specified as an hour (0-23). Default is 2. Specify the minute to begin or end Daylight Savings Time. May be specified as a minute (0-59). Disables automatic Daylight Savings Time.

Automatic Daylight Savings Time changes can be enabled or disabled. The default setting is enabled. To disable automatic Daylight Savings Time, use the command:
configure timezone {name <std_timezone_ID>} <GMT_offset> noautodst

3 Enable the SNTP client using the following command:


enable sntp-client

After SNTP has been enabled, the switch sends out a periodic query to the NTP servers defined in step 4 (if configured) or listens to broadcast NTP updates from the network. The network time information is automatically saved into the onboard real-time clock. 4 If you would like this switch to use a directed query to the NTP server, configure the switch to use the NTP server(s). If the switch listens to NTP broadcasts, skip this step. To configure the switch to use a directed query, use the following command:
configure sntp-client [primary | secondary] <host-name-or-ip> {vr <vr_name>}

NTP queries are first sent to the primary server. If the primary server does not respond within 1 second, or if it is not synchronized, the switch queries the secondary server (if one is configured). If the switch cannot obtain the time, it restarts the query process. Otherwise, the switch waits for the sntp-client update interval before querying again. 5 Optionally, the interval for which the SNTP client updates the real-time clock of the switch can be changed using the following command:
configure sntp-client update-interval <update-interval>

The default sntp-client update-interval value is 64 seconds. 6 You can verify the configuration using the following commands:

show sntp-client

This command provides configuration and statistics associated with SNTP and its connectivity to the NTP server.

show switch {detail}

This command indicates the GMT offset, the Daylight Savings Time configuration and status, and the current local time.

94

ExtremeWare XOS 11.3 Concepts Guide

Using the Simple Network Time Protocol NTP updates are distributed using GMT time. To properly display the local time in logs and other timestamp information, the switch should be configured with the appropriate offset to GMT based on geographical location. Table 15 lists GMT offsets.

Table 15: Greenwich Mean Time offsets


GMT Offset in Hours +0:00 GMT Offset in Minutes +0

Common Time Zone References GMT - Greenwich Mean UT or UTC - Universal (Coordinated) WET - Western European

Cities London, England; Dublin, Ireland; Edinburgh, Scotland; Lisbon, Portugal; Reykjavik, Iceland; Casablanca, Morocco Cape Verde Islands Azores Brasilia, Brazil; Buenos Aires, Argentina; Georgetown, Guyana

-1:00 -2:00 -3:00 -4:00 -5:00 -6:00 -7:00 -8:00 -9:00 -10:00

-60 -120 -180 -240 -300 -360 -420 -480 -540 -600

WAT - West Africa AT - Azores

AST - Atlantic Standard EST - Eastern Standard CST - Central Standard MST - Mountain Standard PST - Pacific Standard YST - Yukon Standard AHST - Alaska-Hawaii Standard CAT - Central Alaska HST - Hawaii Standard

Caracas; La Paz Bogota, Columbia; Lima, Peru; New York, NY, Trevor City, MI USA Mexico City, Mexico Saskatchewan, Canada Los Angeles, CA, Santa Clara, CA, Seattle, WA USA

-11:00 -12:00 +1:00

-660 -720 +60

NT - Nome IDLW - International Date Line West CET - Central European FWT - French Winter MET - Middle European MEWT - Middle European Winter SWT - Swedish Winter Paris France; Berlin, Germany; Amsterdam, The Netherlands; Brussels, Belgium; Vienna, Austria; Madrid, Spain; Rome, Italy; Bern, Switzerland; Stockholm, Sweden; Oslo, Norway

+ 2:00

+120

EET - Eastern European, Russia Zone 1

Athens, Greece; Helsinki, Finland; Istanbul, Turkey; Jerusalem, Israel; Harare, Zimbabwe Kuwait; Nairobi, Kenya; Riyadh, Saudi Arabia; Moscow, Russia; Tehran, Iran Abu Dhabi, UAE; Muscat; Tblisi; Volgograd; Kabul New Delhi, Pune, Allahabad, India

+3:00 +4:00 +5:00 +5:30 +6:00 +7:00 +8:00 +9:00

+180 +240 +300 +330 +360 +420 +480 +540

BT - Baghdad, Russia Zone 2 ZP4 - Russia Zone 3 ZP5 - Russia Zone 4 IST - India Standard Time ZP6 - Russia Zone 5 WAST - West Australian Standard CCT - China Coast, Russia Zone 7 JST - Japan Standard, Russia Zone 8

ExtremeWare XOS 11.3 Concepts Guide

95

Managing the Switch

Table 15: Greenwich Mean Time offsets (Continued)


GMT Offset in Hours +10:00 GMT Offset in Minutes +600

Common Time Zone References EAST - East Australian Standard GST - Guam Standard Russia Zone 9

Cities

+11:00 +12:00

+660 +720 IDLE - International Date Line East NZST - New Zealand Standard NZT - New Zealand Wellington, New Zealand; Fiji, Marshall Islands

SNTP Example
In this example, the switch queries a specific NTP server and a backup NTP server. The switch is located in Cupertino, California, and an update occurs every 20 minutes. The commands to configure the switch are as follows:
configure timezone -480 autodst configure sntp-client update-interval 1200 enable sntp-client configure sntp-client primary 10.0.1.1 configure sntp-client secondary 10.0.1.2

96

ExtremeWare XOS 11.3 Concepts Guide

Managing the ExtremeWare XOS Software

This chapter covers the following topics:


Overview of the ExtremeWare XOS Software on page 97 Using the ExtremeWare XOS File System on page 98 Managing the Configuration File on page 102 Managing ExtremeWare XOS Processes on page 103 Understanding Memory Protection on page 105 Monitoring CPU Utilization on page 106

Overview of the ExtremeWare XOS Software


The ExtremeWare XOS software platform is a distributed software architecture. The distributed architecture consists of separate binary images organized into discreet software modules with messaging between them. The software and system infrastructure subsystem form the basic framework of how the ExtremeWare XOS applications interact with each other, including the system startup sequence, memory allocation, and error events handling. Redundancy and data replication is a built-in mechanism of ExtremeWare XOS. The system infrastructure provides basic redundancy support and libraries for all of the ExtremeWare XOS applications.

Understanding the ExtremeWare XOS Software


NOTE
For information about downloading and upgrading a new software image, saving configuration changes, and upgrading the BootROM, see Appendix A, Software Upgrade and Boot Options.

Like any advanced operating system, ExtremeWare XOS gives you the tools to manage your switch and create your network configurations. With the introduction of ExtremeWare XOS, the following enhancements and functionality have been added to the switch operating system:

File system administration Configuration file management Process control Memory protection CPU monitoring

File system administrationWith the enhanced file system, you can move, copy, and delete files from the switch. The file system structure allows you to keep, save, rename, and maintain multiple copies of configuration files on the switch. In addition, you can manage other entities of the switch such as policies and access control lists (ACLs).

ExtremeWare XOS 11.3 Concepts Guide

97

Managing the ExtremeWare XOS Software Configuration file managementWith the enhanced configuration file management, you can oversee and manage multiple configuration files on your switch. In addition, you can upload, download, modify, and name configuration files used by the switch. Process controlWith process control, you can stop and start processes, restart failed processes, and update the software for a specific process or set of processes. Memory protectionWith memory protection, each function can be bundled into a single application module running as a memory protected process under real-time scheduling. In essence, ExtremeWare XOS protects each process from every other process in the system. If one process experiences a memory fault, that process cannot affect the memory space of another process. CPU monitoringWith CPU monitoring, you can monitor CPU utilization for Management Switch Fabric Modules (MSMs) and the individual processes running on the switch. Monitoring the workload of the CPU allows you to troubleshoot and identify suspect processes. The following sections describe in more detail how to manage the ExtremeWare XOS software.

Using the ExtremeWare XOS File System


The file system in ExtremeWare XOS is the structure by which files are organized, stored, and named. The switch can store multiple user-defined configuration and policy files, each with its own name. Using a series of commands, you can manage the files on your system. For example, you can rename or copy a configuration file on the switch, display a comprehensive list of the configuration and policy files on the switch, or delete a policy file from the switch.

NOTE
Filenames are case-sensitive. For information on filename restrictions, please refer to the specific command in the ExtremeWare XOS Command Reference Guide.

You can also download configuration and policy files from the switch to a network Trivial File Transfer Protocol (TFTP) server using TFTP. For detailed information about downloading switch configurations, see Chapter A, Software Upgrade and Boot Options. For detailed information about downloading policies and ACLs, see Chapter 12, Policy Manager. This section describes the following file management topics:

Moving or Renaming Files on the Switch on page 98 Copying Files on the Switch on page 99 Displaying Files on the Switch on page 100 Deleting Files From the Switch on page 101

Moving or Renaming Files on the Switch


To move or rename an existing configuration or policy file in the system, use the following command:
mv {memorycard} <old-name> {memorycard} <new-name>

98

ExtremeWare XOS 11.3 Concepts Guide

Using the ExtremeWare XOS File System Where the following is true:

memorycardSpecifies the removable external compact flash memory card. (This parameter is available only on modular switches.) old-nameSpecifies the current name of the configuration or policy file. new-nameSpecifies the new name of the configuration or policy file.

Configuration files have a .cfg file extension; policy files have a .pol file extension. When you rename a file, make sure the renamed file uses the same file extension as the original file. If you change the file extensions, the file may be unrecognized by the system. For example, if you have an existing configuration file named test.cfg, the new filename must include the .cfg file extension. When you rename a file on the switch, a message similar to the following appears:
Rename config test.cfg to config megtest.cfg on switch? (y/n)

Enter y to rename the file on your system. Enter n to cancel this process and keep the existing filename.

Modular Switches Only


This command also replicates the action from the primary MSM to the backup MSM. For example, if you rename a file on the primary MSM, the same file on the backup MSM is renamed. For the memorycard option, this command can move files between the external memory card and the switch. If you use the memorycard option for both the old-name and the new-name, this command only renames a file on the external memory card.

Examples
The following example renames the configuration file named Test.cfg to Final.cfg:
mv Test.cfg Final.cfg

On a modular switch, the following command moves the configuration file named test1.cfg from the switch to the external memory card:
mv test1.cfg memorycard test1.cfg

Copying Files on the Switch


The copy function allows you to make a copy of an existing file before you alter or edit the file. By making a copy, you can easily go back to the original file if needed. To copy an existing configuration or policy file on your switch, use the following command:
cp {memorycard} <old-name> {memorycard} <new-name>

Where the following is true:

memorycardSpecifies the removable external compact flash memory card. (This parameter is available only on modular switches.) old-nameSpecifies the name of the configuration or policy file that you want to copy. new-nameSpecifies the name of the copied configuration or policy file.

ExtremeWare XOS 11.3 Concepts Guide

99

Managing the ExtremeWare XOS Software Configuration files have a .cfg file extension; policy files have a .pol file extension. When you copy a configuration or policy file from the system, make sure you specify the appropriate file extension. For example, if you want to copy a policy file, specify the filename and .pol. When you copy a file on a the switch, a message similar to the following appears:
Copy config test.cfg to config test1.cfg on switch? (y/n)

Enter y to copy the file. Enter n to cancel this process and not copy the file. If you enter y, the switch copies the file with the new name and keeps a backup of the original file with the original name. After the switch copies the file, use the ls command to display a complete list of files.

Modular Switches Only


This command also replicates the action from the primary MSM to the backup MSM. For example, if you copy a file on the primary MSM, the same file is copied to the backup MSM. For the memorycard option, the source and/or destination is the memorycard. You must mount the memory card for this operation to succeed. This command copies a file from the switch to the external memory card or a file already on the card. If you copy a file from the switch to the external memory card, and the new filename is identical to the source file, you do not need to re-enter the filename.

Example
The following example copies an existing configuration file named test.cfg and names the copied configuration file test_rev2.cfg:
cp test.cfg test_rev2.cfg

On a modular switch, the following command makes a copy of a configuration file named primary.cfg from the switch to the external memory card with the same name, primary.cfg:
cp primary.cfg memorycard

Displaying Files on the Switch


To display a list of the configuration and policy files stored on your switch, use the following command:
ls {memorycard}

Where the memorycard option lists all of the files on the external memory card. (Modular switches only.) Output from this command includes the file size, date and time the file was last modified, and the file name.

100

ExtremeWare XOS 11.3 Concepts Guide

Using the ExtremeWare XOS File System

Example
The following command displays all of the configuration and policy files stored on your switch:
ls

The following is sample output from this command:


total 424 -rw-r--r--rw-r--r--rw-r--r--rw-r--r--rw-r--r--rw-r--r-1 1 1 1 1 1 root root root root root root root root root root root root 50 94256 100980 35 100980 94256 Jul Jul Sep Jun Sep Jun 30 23 23 29 23 30 14:19 14:26 09:16 06:42 09:17 17:10 hugh.pol hughtest.cfg megtest.cfg newpolicy.pol primary.cfg roytest.cfg

On a modular switch, the following command displays all of the configuration and policy files stored on the external memory card:
ls memorycard

The following is sample output from this command:


-rwxr-xr-x -rwxr-xr-x -rwxr-xr-x -rwxr-xr-x -rwxr-xr-x 1 1 1 1 1 root root root root root 0 0 0 0 0 15401865 10 10 10 223599 Mar Mar Apr Mar Mar 30 31 4 31 31 00:03 09:41 09:15 09:41 10:02 bd10K-11.2.0.13.xos test-1.pol test.pol test_1.pol v11_1_3.cfg

Deleting Files From the Switch


To delete a configuration or policy file from your system, use the following command:
rm {memorycard} <file-name>

Where the following is true:

memorycardSpecifies the removable external compact flash card. (This parameter is available only

on modular switches.)

file-nameSpecifies the name of the configuration or policy file to delete.

When you delete a configuration or policy file from the system, make sure you specify the appropriate file extension. For example, if you want to delete a policy file, specify the filename and .pol. After you delete a file, it is unavailable to the system. When you delete a file from the switch, a message similar to the following appears:
Remove testpolicy.pol from switch? (y/n)

Enter y to remove the file from your system. Enter n to cancel the process and keep the file on your system.

Modular Switches Only


This command also replicates the action from the primary MSM to the backup MSM. For example, if you delete a file on the primary MSM, the same file on the backup MSM is deleted.

ExtremeWare XOS 11.3 Concepts Guide

101

Managing the ExtremeWare XOS Software For the memorycard option, this command removes/deletes an existing file on the external memory card.

Example
The following example removes the policy file named newpolicy.pol from the system:
rm newpolicy.pol

On a modular switch with an external memory card installed, the following command removes the policy file named test.pol from the external memory card:
rm memorycard test.pol

Managing the Configuration File


The configuration is the customized set of parameters that you have selected to run on the switch. Table 16 describes some of the key areas of configuration file management in ExtremeWare XOS.

Table 16: Configuration file management


Task Configuration file database Behavior ExtremeWare XOS supports saving a configuration file into any named file and supports more than two saved configurations. For example, you can download a configuration file from a network TFTP server and save that file as primary, secondary, or with a user-defined name. You also select where to save the configuration: primary or secondary partition, or another space. The file names primary and secondary exist for backward compatibility with ExtremeWare. Downloading configuration files ExtremeWare XOS uses the tftp command to download configuration files to the switch from the network TFTP server. For more information about downloading configuration files, see Using TFTP to Download the Configuration on page 603. Uploading configuration files ExtremeWare XOS uses the tftp command to upload configuration files from the switch to the network TFTP server. For more information about uploading configuration files, see Using TFTP to Upload the Configuration on page 603. Managing configuration files, including listing, copying, deleting, and renaming The following commands allow you to manage configuration files: lsLists all of the configuration files in the system. cpMakes a copy of an existing configuration file in the system. rmRemoves/deletes an existing configuration file from the system. mvRenames an existing configuration file. Configuration file type ExtremeWare XOS configuration files are saved in Extensible Markup Language (XML) format. Use the show configuration command to view on the CLI your currently running switch configuration. Indicated by (xml) at the front of the switch prompt. Do not use. Use the command disable xml-mode to disable this mode. You can also see a complete list of configuration files by entering the ls command followed by the Tab key.

XML configuration mode Displaying configuration files

102

ExtremeWare XOS 11.3 Concepts Guide

Managing ExtremeWare XOS Processes For more information about saving, uploading, and downloading configuration files, see Saving Configuration Changes on page 601.

Managing ExtremeWare XOS Processes


ExtremeWare XOS consists of a number of cooperating processes running on the switch. With process control, under certain conditions, you can stop and start processes, restart failed processes, examine information about the processes, and update the software for a specific process or set of processes. This section describes the following topics:

Displaying Process Information on page 103 Stopping a Process on page 104 Starting a Process on page 105

Displaying Process Information


To display information about the processes in the system, use the following command:
show process {<name>} {detail} {description} {slot <slotid>}

Where the following is true:


nameSpecifies the name of the process. detailSpecifies more detailed process information, including memory usage statistics, process ID information, and process statistics. descriptionDescribes the name of all of the processes or the specified process running on the

switch.

slotidSpecifies the slot number of the MSM. A specifies the MSM installed in slot A. B specifies

the MSM installed in slot B. (This parameter is available only on modular switches.) The show process and show process slot <slotid> commands display the following information in a tabular format:

CardThe name of the module where the process is running (modular switches only). Process NameThe name of the process. VersionThe version number of the process. Options are:

Version numberA series of numbers that identify the version number of the process. This is helpful to ensure that you have version-compatible processes and if you experience a problem. Not StartedThe process has not been started. This can be caused by not having the appropriate license or for not starting the process.

RestartThe number of times the process has been restarted. This number increments by one each time a process stops and restarts. StateThe current state of the process. Options are:

No LicenseThe process requires a license level that you do not have. For example, you have not upgraded to that license, or the license is not available for your platform. ReadyThe process is running. StoppedThe process has been stopped.

ExtremeWare XOS 11.3 Concepts Guide

103

Managing the ExtremeWare XOS Software

Start TimeThe current start time of the process. Options are:

Day/Month/Date/Time/YearThe date and time the process began. If a process terminates and restarts, the start time is also updated. Not StartedThe process has not been started. This can be caused by not having the appropriate license or for not starting the process.

If you specify the detail keyword, more specific and detailed process information is displayed. The show process detail and show process slot <slotid> detail commands display the following information in a multi-tabular format:

Detailed process information Memory usage configurations Recovery policies Process statistics Resource usage

Stopping a Process
If recommended by Extreme Networks Technical Support personnel, you can stop a running process. To stop a running process, use the following command:
terminate process <name> [forceful | graceful] {msm <slot>}

Where the following is true:


nameSpecifies the name of the process. forcefulSpecifies that the software quickly terminate a process. Unlike the graceful option, the process is immediately shutdown without any of the normal process cleanup. gracefulSpecifies that the process shutdown gracefully by closing all opened connections,

notifying peers on the network, and other types of process cleanup.

slotSpecifies the slot number of the MSM. A specifies the MSM installed in slot A. B specifies the MSM installed in slot B. (This parameter is available only on modular switches.)

NOTE
Do not terminate a process that was installed since the last reboot unless you have saved your configuration. If you have installed a software module and you terminate the newly installed process without saving your configuration, your module may not be loaded when you attempt to restart the process with the start process command.

You can also use a single command to stop and restart a running process during a software upgrade on the switch. By using the single command, there is less process disruption and it takes less time to stop and restart the process. To stop and restart a process during a software upgrade, use the following command:
restart process [class <cname> | <name> {msm <slot>}]

Where the following is true:

cnameSpecifies that the software terminates and restarts all instances of the process associated with

a specific routing protocol on all VRs.

nameSpecifies the name of the process.

104

ExtremeWare XOS 11.3 Concepts Guide

Understanding Memory Protection

Starting a Process
To start a process, use the following command:
start process <name> {msm <slot>}

Where the following is true:


nameSpecifies the name of the process. slotSpecifies the slot number of the MSM. A specifies the MSM installed in slot A. B specifies the MSM installed in slot B. (This parameter is available only on modular switches.)

You are unable to start a process that is already running. If you try to start a currently running process, for example telnetd, an error message similar to the following appears:
Error: Process telnetd already exists!

As described in the section, Stopping a Process on page 104, you can use a single command, rather than multiple commands, to stop and restart a running process. To stop and restart a process during a software upgrade, use the following command:
restart process [class <cname> | <name> {msm <slot>}]

For more detailed information, see the previous section or the ExtremeWare XOS Command Reference Guide.omm

Understanding Memory Protection


ExtremeWare XOS provides memory management capabilities. With ExtremeWare XOS, each process runs in a protected memory space. This infrastructure prevents one process from overwriting or corrupting the memory space of another process. For example, if one process experiences a loop condition, is under some type of attack, or is experiencing some type of problem, that process cannot take over or overwrite another processes memory space. Memory protection increases the robustness of the system. By isolating and having separate memory space for each individual process, you can more easily identify the process or processes that experience a problem. To display the current system memory and that of the specified process, use the following command:
show memory process <name> {slot <slotid>}

Where the following is true:


nameSpecifies the name of the process. slotSpecifies the slot number of the MSM. A specifies the MSM installed in slot A. B specifies the MSM installed in slot B. (This parameter is available only on modular switches.)

The show memory process command displays the following information in a tabular format:

System memory information (both total and free). Current memory used by the individual processes.

ExtremeWare XOS 11.3 Concepts Guide

105

Managing the ExtremeWare XOS Software The current memory statistics for the individual process also includes the following:

The module (MSM A or MSM B) and the slot number of the MSM (modular switches only). The name of the process.

You can also use the show memory {slot [a | b]} command to view the system memory and the memory used by the individual processes, even for all processes on all MSMs installed in modular switches. The slot parameter is available only on modular switches. In general, the free memory count for an MSM or Summit X450 switch decreases when one or more running processes experiences an increase in memory usage. If you have not made any system configuration changes, and you observe a continued decrease in free memory, this might indicate a memory leak. The information from these commands may be useful for your technical support representative if you experience a problem.

Monitoring CPU Utilization


You can monitor the CPU utilization and history for all of the processes running on the switch. By viewing this history on a regular basis, you can see trends emerging and identify processes with peak utilization. Monitoring the workload of the CPU allows you to troubleshoot and identify suspect processes before they become a problem. By default, the switch monitors CPU utilization every 20 seconds. In addition, if CPU utilization of a process exceeds 60% of the regular operating basis, the switch logs an error message specifying the process name and the current CPU utilization for the process.

Disabling CPU Monitoring


To disable CPU monitoring, use the following command:
disable cpu-monitoring

This command disables CPU monitoring on the switch; however, it does not clear the monitoring interval. Therefore, if you altered the monitoring interval, this command does not return the monitoring interval to 20 seconds. The next time you enable CPU monitoring, the switch uses the existing configured interval.

Enabling CPU Monitoring


To enable CPU monitoring, use the following command:
enable cpu-monitoring {interval <seconds>} {threshold <percent>}

Where the following is true:

secondsSpecifies the monitoring interval. The default interval is 20 seconds, and the range is 5 to

60 seconds. Extreme Networks recommends the default setting for most network environments. If you enter a number lower than 20 seconds, CPU utilization may increase.

thresholdSpecifies the CPU threshold value. CPU usage is measured in percentages. The default is 60%, and the range is 0% to 100%.

106

ExtremeWare XOS 11.3 Concepts Guide

Monitoring CPU Utilization By default, CPU monitoring is enabled and occurs every 20 seconds. The default CPU threshold value is 60%.

Displaying CPU Utilization History


To display the CPU utilization history of one or more processes, use the following command:
show cpu-monitoring {process <name>} {slot <slotid>}

Where the following is true:


nameSpecifies the name of the process. slotSpecifies the slot number of the MSM. A specifies the MSM installed in slot A. B specifies the MSM installed in slot B. (This parameter is available only on modular switches.)

Output from this command includes the following information:


The location where the process is running The name of the process The CPU utilization history of the process or the system The CPU usage of the process or the system

The following is sample truncated output from a modular switch:


show cpu-monitoring CPU Utilization Statistics - Monitored every 5 seconds ------------------------------------------------------------------------------Card 5 10 30 1 5 30 1 Max Total secs secs secs min mins mins hour User/System util util util util util util util util CPU Usage (%) (%) (%) (%) (%) (%) (%) (%) (secs) ------------------------------------------------------------------------------MSM-A MSM-B MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A System System GNSS_cpuif GNSS_ctrlif GNSS_esmi GNSS_fabric GNSS_mac_10g GNSS_pbusmux GNSS_pktengine GNSS_pktif GNSS_switch aaa acl bgp cfgmgr cli devmgr dirser dosprotect eaps 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.9 0.0 0.0 0.0 0.0 0.9 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3.7 48.3 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.2 9.6 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.2 2.5 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.3 2.1 0.2 0.0 0.0 0.0 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 8.4 7.5 5.2 27.3 48.3 17.1 9.5 3.8 8.4 Process

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.82 0.37 0.27 7.70 0.51 2.22 0.0 0.20 2.40

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.56 0.33 0.42 7.84 0.37 2.50 0.0 0.26 1.40

ExtremeWare XOS 11.3 Concepts Guide

107

Managing the ExtremeWare XOS Software


MSM-A MSM-A MSM-A MSM-A MSM-A MSM-A ... edp elrp ems epm esrp etmon 0.0 0.0 0.0 0.0 0.0 0.9 0.0 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.0 0.0 0.0 0.6 0.0 0.0 0.0 0.9 0.0 1.2 0.0 0.0 0.0 0.1 0.0 1.1 0.0 0.0 0.0 0.2 0.0 1.0 0.0 0.0 0.0 0.2 0.0 1.0 10.2 8.4 12.2 4.7 7.5 23.3 0.99 0.44 1.1 2.6 0.44 21.84 0.47 0.28 1.16 4.18 0.36 7.24

The following is sample truncated output from a Summit X450 switch:


CPU Utilization Statistics - Monitored every 25 seconds ----------------------------------------------------------------------Process 5 10 30 1 5 30 1 Max Total secs secs secs min mins mins hour User/System util util util util util util util util CPU Usage (%) (%) (%) (%) (%) (%) (%) (%) (secs) ----------------------------------------------------------------------System aaa acl bgp cfgmgr cli devmgr dirser dosprotect eaps edp elrp ems epm esrp etmon ... n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.0 0.0 0.0 0.8 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.5 34.6 1.8 0.0 12.6 39.8 0.0 19.5 0.0 0.0 5.5 11.1 0.0 0.0 30.7 2.7 30.5

1.72 0.40 11.18 4743.92 0.59 74.44 0.0 0.8 36.40 10.92 0.49 1.19 48.74 0.82 4865.78

0.78 0.24 2.21 3575.79 0.42 24.52 0.0 0.12 15.41 3.97 0.44 1.29 32.93 0.45 873.87

108

ExtremeWare XOS 11.3 Concepts Guide

Configuring Slots and Ports on a Switch

This chapter covers the following topics:

Configuring a Slot on a Modular SwitchBlackDiamond 10K Switch and BlackDiamond 8800 Family of Switches Only on page 109 Configuring Ports on a Switch on page 111 Jumbo Frames on page 116 Link Aggregation on the Switch on page 119 Switch Port Mirroring on page 130 Extreme Discovery Protocol on page 134 Software-Controlled Redundant Port and Smart Redundancy on page 135 Configuring Automatic Failover for Combination PortsSummit X450 Switch Only on page 139 Displaying Port Configuration Information on page 140

Configuring a Slot on a Modular SwitchBlackDiamond 10K Switch and BlackDiamond 8800 Family of Switches Only
NOTE
The BlackDiamond 8800 family of switches was formerly known as Aspen.

This section discusses configuring slots on a modular switch, which are the BlackDiamond 10K switch and the BlackDiamond 8800 family of switches. The following topics are discussed:

Overview on page 109 I/O Ports on BlackDiamond 8810 MSM Module on page 110 I/O Ports on BlackDiamond 8806 MSM Module on page 111

Overview
If a slot has not been configured for a particular type of module, then any type of module is accepted in that slot, and a default port and VLAN configuration is automatically generated. After any port on the module has been configured (for example, a VLAN association, a VLAN tag configuration, or port parameters), all the port information and the module type for that slot must be saved to non-volatile storage. Otherwise, if the modular switch is rebooted or the module is removed from the slot, the port, VLAN, and module configuration information is not saved.

ExtremeWare XOS 11.3 Concepts Guide

109

Configuring Slots and Ports on a Switch

NOTE
For information on saving the configuration, see Appendix A.

You configure the modular switch with the type of input/output (I/O) module that is installed in each slot. To do this, use the following command:
configure slot <slot> module <module_type>

You can also preconfigure the slot before inserting the module. This allows you to begin configuring the module and ports before installing the module in the chassis. If a slot is configured for one type of module, and a different type of module is inserted, the inserted module is put into a mismatch state and is not brought online. To use the new module type in a slot, the slot configuration must be cleared or configured for the new module type. To clear the slot of a previously assigned module type, use the following command:
clear slot <slot>

All configuration information related to the slot and the ports on the module is erased. If a module is present when you issue this command, the module is reset to default settings. To display information about a particular slot, use the following command:
show slot

Information displayed includes:


Module type, part number and serial number. Current state (power down, operational, diagnostic, mismatch). Port information.

If no slot is specified, information for all slots is displayed.

I/O Ports on BlackDiamond 8810 MSM Module


NOTE
You must have at least one MSM in the BlackDiamond 8810 switch.

On the BlackDiamond 8810 switch (formerly known as Aspen), the MSM module also has eight 1 Gbps fiber SFP GBIC data, or I/O, ports. You configure these ports exactly as you do any other ports on the switch. Additionally, one slot on the BlackDiamond 8810 switch is dedicated to MSM useslot A, or slot 5. Slot B, or slot 6, is a dual-purpose slot; it can be used for a secondary MSM or for a module consisting solely of data, or I/O, ports. The primary MSM must be in slot A in the BlackDiamond 8810 switch, which is referred to as slot 5 when working with the data ports. If you have a secondary MSM, that one goes into slot B, which is slot 6 when you work with the data ports. So, when you work with the data ports on the MSM, you specify slot 5 if you have one MSM, and slot 5 or 6 if you have two MSMs in the switch.

110

ExtremeWare XOS 11.3 Concepts Guide

Configuring Ports on a Switch When you issue any slot commands specifying a slot that contains an MSM (slot 5 with one MSM and slots 5 and 6 with two MSMs) on the BlackDiamond 8810 switch, those commands affect only the data ports on that slot; the MSMs remain unaffected. When you issue most msm commands on this switch, those commands affect only the MSM host CPU subsystem; the I/O ports remain unaffected. The sole exception is that the reboot msm command reboots both the MSM and the I/O ports on that module. If you are working on a switch with dual MSMs and the system fails over to the backup MSM from the primary MSM, the I/O ports on the original primary MSM are not available during the failover period. It takes about 2 minutes for the I/O ports on the original MSM to be able to pass traffic once again.

I/O Ports on BlackDiamond 8806 MSM Module


NOTE
You must have at least one MSM in the BlackDiamond 8806 switch.

On the BlackDiamond 8806 switch, the MSM module also has eight 1 Gbps fiber SFP GBIC data, or I/O, ports. You configure these ports exactly as you do any other ports on the switch. Additionally, one slot on the BlackDiamond 8806 switch is dedicated to MSM useslot A, or slot 3. Slot B, or slot 4, is a dual-purpose slot; it can be used for a secondary MSM or for a module consisting solely of data, or I/O, ports. The primary MSM must be in slot A in the BlackDiamond 8806 switch, which is referred to as slot 3 when working with the data ports. If you have a secondary MSM, that one goes into slot B, which is slot 4 when you work with the data ports. So, when you work with the data ports on the MSM, you specify slot 3 if you have one MSM, and slot 3 or 4 if you have two MSMs in the switch. When you issue any slot commands specifying a slot that contains an MSM (slot 3 with one MSM and slots 3 and 4 with two MSMs) on the BlackDiamond 8806 switch, those commands affect only the data ports on that slot; the MSMs remain unaffected. When you issue most msm commands on this switch, those commands affect only the MSM host CPU subsystem; the I/O ports remain unaffected. The sole exception is that the reboot msm command reboots both the MSM and the I/O ports on that module. If you are working on a switch with dual MSMs and the system fails over to the backup MSM from the primary MSM, the I/O ports on the original primary MSM are not available during the failover period. It takes about 2 minutes for the I/O ports on the original MSM to be able to pass traffic once again.

Configuring Ports on a Switch


NOTE
Beginning with ExtremeWare XOS version 11.2, a port can belong to multiple virtual routers (VRs). See Chapter 10 for more information on VRs.

This section covers the following topics of configuring ports on a switch:


Port Numbering on page 112 Enabling and Disabling Switch Ports on page 113

ExtremeWare XOS 11.3 Concepts Guide

111

Configuring Slots and Ports on a Switch

Configuring Switch Port Speed and Duplex Setting on page 113

Port Numbering
ExtremeWare XOS runs on both stand-alone and modular switches, and the port numbering scheme is slightly different on each. This section cover the following topics:

Stand-alone Switch Numerical Ranges on page 112 Modular Switch Numerical Ranges on page 112

Stand-alone Switch Numerical Ranges


On a stand-alone switch, such as the Summit X450 switch, the port number is simply noted by the physical port number, as shown below:
5

Separate the port numbers by a dash to enter a range of contiguous numbers, and separate the numbers by a comma to enter a range of noncontiguous numbers:

x-ySpecifies a contiguous series of ports on a stand-alone switch. x,ySpecifies a non contiguous series of ports on a stand-alone switch. x-y,a,dSpecifies a contiguous series of ports and a series of noncontagious ports on a stand-alone

switch.

Modular Switch Numerical Ranges


On a modular switch, such as the BlackDiamond 10K, the port number is a combination of the slot number and the port number. The nomenclature for the port number is as follows:
slot:port

For example, if an I/O module that has a total of four ports is installed in slot 2 of the chassis, the following ports are valid:

2:1 2:2 2:3 2:4

You can also use wildcard combinations (*) to specify multiple modular slot and port combinations. The following wildcard combinations are allowed:

slot:*Specifies all ports on a particular I/O module. slot:x-slot:ySpecifies a contiguous series of ports on a particular I/O module. slot:x-ySpecifies a contiguous series of ports on a particular I/O module. slota:x-slotb:ySpecifies a contiguous series of ports that begin on one I/O module and end on another I/O module.

112

ExtremeWare XOS 11.3 Concepts Guide

Configuring Ports on a Switch

Enabling and Disabling Switch Ports


By default, all ports are enabled. To enable or disable one or more ports on a switch, use the following commands:
enable port [<port_list> | all] disable port [<port_list> | all]

For example, to disable slot 7, ports 3, 5, and 12 through 15 on a modular switch, use the following command:
disable port 7:3,7:5,7:12-7:15

Refer to Displaying Port Configuration Information for information on displaying link status.

Configuring Switch Port Speed and Duplex Setting


NOTE
Refer to Displaying Port Configuration Information for information on displaying port speed, duplex, autonegotiation, and flow control settings.

ExtremeWare XOS supports the following port types:


10 Gbps ports 10/100/1000 Mbps copper ports 10/100/1000 Mbps copper ports with Power over Ethernet (PoE) 1 Gbps small form factor (SFP) gigabit Ethernet interface converter (GBIC) fiber ports

Autonegotiation determines the port speed and duplex setting for each port (except 10 Gbps ports). You can manually configure the duplex setting and the speed of 10/100/1000 Mbps ports. The 10/100/1000 Mbps ports can connect to either 10BASE-T, 100BASE-T, or 1000BASE-T networks. By default, the ports autonegotiate port speed. You can also configure each port for a particular speed (either 10 Mbps or 100 Mbps). SFP GBIC ports are statically set to 1 Gbps, and their speed cannot be modified; the 10 Gbps ports always run at full duplex and 10 Gbps. To configure port speed and duplex setting, use the following command:
configure ports <port_list> auto off speed [10 | 100 | 1000 | 10000] duplex [half | full]

To configure the system to autonegotiate, use the following command:


configure ports <port_list> auto on

Flow control on Gigabit Ethernet ports is enabled or disabled as part of autonegotiation. If autonegotiation is set to Off on the ports, flow control is disabled. When autonegotiation is turned On, flow control is enabled.

ExtremeWare XOS 11.3 Concepts Guide

113

Configuring Slots and Ports on a Switch The 1 Gbps ports both advertise support and respond to pause frames, but they do not initiate pause frames. The 10 Gbps ports support flow control, and both types of ports initiate and respond to pause frames. ExtremeWare XOS does not support turning off autonegotiation on the management port. Beginning with ExtremeWare XOS 11.1, the 10 Gbps ports support the Link Fault Signal (LFS) function. This function, which is always enabled, monitors the 10 Gbps ports and indicates either a remote fault or a local fault. The system then stops transmitting or receiving traffic from that link. Once the fault is alleviated, the system puts the link back up and the traffic automatically resumes. The Extreme Networks implementation of LFS conforms to the IEEE standard 802.3ae-2002.

NOTE
On the BlackDiamond 10K switch, the 10 Gbps module must have the serial number 804405-00-09 or higher to support LFS. To display the serial number of the module, issue the show slot <slot_number> command. (All the modules on the BlackDiamond 8800 family of switches support LFS.)

Although the physical link remains up, all Layer 2 and above traffic stops. The system sends LinkDown and LinkUp traps when these events occur. Additionally, the system writes one or more information messages to the syslog, as shown in the following example:
09/09/2004 14:59:08.03 <Info:vlan.dbg.info> MSM-A: Port 4:3 link up at 10 Gbps speed and full-duplex 09/09/2004 14:59:08.02 <Info:hal.sys.info> MSM-A: 4:3 - remote fault recovered. 09/09/2004 14:59:05.56 <Info:vlan.dbg.info> MSM-A: Port 4:3 link down due to remote fault 09/09/2004 14:59:05.56 <Info:hal.sys.info> MSM-A: 4:3 - remote fault. 09/09/2004 15:14:12.22 <Info:hal.sys.info> MSM-A: 4:3 - local fault recovered. 09/09/2004 15:14:11.35 <Info:vlan.dbg.info> MSM-A: Port 4:3 link up at 10 Gbps speed and full-duplex 09/09/2004 15:13:33.56 <Info:vlan.dbg.info> MSM-A: Port 4:3 link down due to local fault 09/09/2004 15:13:33.56 <Info:hal.sys.info> MSM-A: 4:3 - local fault. 09/09/2004 15:13:33.49 <Info:vlan.dbg.info> MSM-A: Port 4:3 link down due to local fault

NOTE
A link down or up event may trigger Spanning Tree Protocol topology changes or transitions.

Turning Off Autonegotiation on a Gigabit Ethernet Port


In certain interoperability situations, you may need to turn autonegotiation off on a fiber gigabit Ethernet port. Although a gigabit Ethernet port runs only at full duplex, you must specify the duplex setting. The following example turns autonegotiation off for port 1 (a 1 Gbps Ethernet port) on a module located in slot 1 of a modular switch:

114

ExtremeWare XOS 11.3 Concepts Guide

Configuring Ports on a Switch


configure ports 1:1 auto off duplex full

The 10 Gbps ports do not autonegotiate; they always run at full duplex and 10 Gbps speed. Table 17 lists the support for autonegotiation, speed, and duplex setting for the various types of ports.

Table 17: Support for autonegotiation on various ports


Port 10 Gbps 10/100/1000 Mbps Autonegotiation Off On (default) Off 1 Gbps fiber SFP GBIC On (default) Off 1000 Mbps Full duplex 10 Mbps 100 Mbps Full/half duplex Full/half duplex Speed 10000 Mbps Duplex Full duplex

Turning off AutopolaritySummit X450 Switch and BlackDiamond 8800 Family of Switches Only
(Autopolarity detection is always on for the BlackDiamond 10K switch.) The autopolarity feature allows the system to detect and respond to the Ethernet cable type (straightthrough or crossover cable) used to make the connection to the switch port. This feature applies to only the 10/100/1000 BASE-T ports on the switch. When the autopolarity feature is enabled, the system causes the Ethernet link to come up regardless of the cable type connected to the port. When the autopolarity feature is disabled, you need a crossover cable to connect other networking equipment and a straight-through cable to connect to endstations. The autopolarity feature is enabled by default. To disable or enable autopolarity detection, use the following command:
configure ports [<port_list> | all] auto-polarity [off | on]

where the following is true:


port_listSpecifies one or more ports on the switch. allSpecifies all of the ports on the switch. offDisables the autopolarity detection feature on the specified ports. onEnables the autopolarity detection feature on the specified ports.

Under certain conditions, you might opt to turn autopolarity off on one or more ports. The following example turns autopolarity off for ports 5 to 7 on a Summit X450 switch:
configure ports 5-7 auto-polarity off

When autopolarity is disabled on one or more Ethernet ports, you can verify that status by using the command:
show ports information detail

ExtremeWare XOS 11.3 Concepts Guide

115

Configuring Slots and Ports on a Switch

Jumbo Frames
Jumbo frames are Ethernet frames that are larger than 1522 bytes, including four bytes used for the cyclic redundancy check (CRC). Extreme products support switching and routing of jumbo frames at wirespeed on all ports. The configuration for jumbo frames is saved across reboots of the switch. Jumbo frames are used between endstations that support larger frame sizes for more efficient transfers of bulk data. Both endstations involved in the transfer must be capable of supporting jumbo frames. The switch only performs IP fragmentation, or participates in maximum transmission unit (MTU) negotiation on behalf of devices that support jumbo frames. You need jumbo frames when running the Extreme Networks VMAN implementation. When you are working on the BlackDiamond 10K switch, the switch enables jumbo frames when you configure VMANs. If you are working on the BlackDiamond 8800 family of switches, you enable jumbo frames for the entire switch prior to configuring VMANs. For more information on configuring VMANs, refer to Chapter 9. Refer to Displaying Port Configuration Information for information on displaying jumbo frame status.

Jumbo Frames on the BlackDiamond 8800 Family of Switches and Summit X450 Switch Only
The following information applies to jumbo frames on the BlackDiamond 8800 family of switches and the Summit X450 switch:

The BlackDiamond 8800 family of switches and the Summit X450 switch support jumbo frames on the entire switch; you cannot enable or disable jumbo frames per port. The BlackDiamond 8800 family of switches and the Summit X450 switch enable or disable jumbo frames on the entire switch; jumbo frames are either enabled or disabled on every port on the switch. The system returns an error message if you attempt to enter specified ports.

To enable jumbo frame support on the BlackDiamond 8800 family of switches or the Summit X450 switch, use the following command:
enable jumbo-frame ports all

Once you issue this command, any new modules you add to the switch will also have jumbo frames enabled.

When you configure VMANs on the BlackDiamond 8800 family of switches and the Summit X450 switch, you must enable jumbo frames for the entire switches prior to configuring the VMANs.

Enabling Jumbo Frames


NOTE
Some network interface cards (NICs) have a configured maximum MTU size that does not include the additional 4 bytes of CRC. Ensure that the NIC maximum MTU size is at or below the maximum MTU size configured on the switch. Frames that are larger than the MTU size configured on the switch are dropped at the ingress port.

To enable jumbo frame support, enable jumbo frames on the desired ports. To set the maximum jumbo frame size, use the following command:

116

ExtremeWare XOS 11.3 Concepts Guide

Jumbo Frames
configure jumbo-frame-size <framesize>

The jumbo frame size range is 1523 to 9216. This value describes the maximum size of the frame in transit (on the wire), and includes 4 bytes of CRC plus another 4 bytes if 802.1Q tagging is being used. Set the MTU size for the VLAN, using the following command:
configure ip-mtu <mtu> vlan <vlan_name>

Next, enable support on the physical ports that will carry jumbo frames using the following command:
enable jumbo-frame ports [all | <port_list>]

NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch enable or disable jumbo frames on the entire switch; the system returns an error message if you attempt to enable jumbo frames on specified ports.

Path MTU Discovery


NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support the router specification for path MTU discovery.

Using path MTU discovery, a source host assumes that the path MTU is the MTU of the first hop (which is known). The host sends all datagrams on that path with the dont fragment (DF) bit set, which restricts fragmentation. If any of the datagrams must be fragmented by an Extreme switch along the path, the Extreme switch discards the datagrams and returns an ICMP Destination Unreachable message to the sending host, with a code meaning fragmentation needed and DF set. When the source host receives the message (sometimes called a Datagram Too Big message), the source host reduces its assumed path MTU and retransmits the datagrams. The path MTU discovery process ends when one of the following is true:

The source host sets the path MTU low enough that its datagrams can be delivered without fragmentation. The source host does not set the DF bit in the datagram headers.

If it is willing to have datagrams fragmented, a source host can choose not to set the DF bit in datagram headers. Normally, the host continues to set DF in all datagrams, so that if the route changes and the new path MTU is lower, the host can perform path MTU discovery again.

IP Fragmentation with Jumbo Frames


NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support fragmentation of any IP packets they forward.

ExtremeWare XOS 11.3 Concepts Guide

117

Configuring Slots and Ports on a Switch ExtremeWare XOS supports the fragmenting of IP packets. If an IP packet originates in a local network that allows large packets and those packets traverse a network that limits packets to a smaller size, the packets are fragmented instead of discarded. This feature is designed to be used in conjunction with jumbo frames. Frames that are fragmented are not processed at wire-speed within the switch fabric.

NOTE
Jumbo frame-to-jumbo frame fragmentation is not supported. Only jumbo frame-to-normal frame fragmentation is supported.

To configure VLANs for IP fragmentation: 1 Enable jumbo frames on the incoming port. NOTE
If you are working with the BlackDiamond 8800 family of switches or a Summit X450, you must enable jumbo frames for the entire switch.

2 Add the port to a VLAN. 3 Assign an IP address to the VLAN. 4 Enable ipforwarding on the VLAN. 5 Set the MTU size for the VLAN, using the following command:
configure ip-mtu <mtu> vlan <vlan_name>

The ip-mtu value ranges between 1500 and 9216, with 1500 the default.

NOTE
To set the MTU size greater than 1500, all ports in the VLAN must have jumbo frames enabled.

IP Fragmentation within a VLAN


ExtremeWare XOS supports IP fragmentation within a VLAN. This feature does not require you to configure the MTU size. To use IP fragmentation within a VLAN: 1 Enable jumbo frames on the incoming port. 2 Add the port to a VLAN. 3 Assign an IP address to the VLAN. 4 Enable ipforwarding on the VLAN. If you leave the MTU size configured to the default value, when you enable jumbo frame support on a port on the VLAN you will receive a warning that the ip-mtu size for the VLAN is not set at maximum jumbo frame size. You can ignore this warning if you want IP fragmentation within the VLAN, only. However, if you do not use jumbo frames, IP fragmentation can only be used for traffic that stays within the same VLAN. For traffic that is set to other VLANs, to use IP fragmentation, all ports in the VLAN must be configured for jumbo frame support.

118

ExtremeWare XOS 11.3 Concepts Guide

Link Aggregation on the Switch

Link Aggregation on the Switch


The link aggregation (also known as load sharing) feature allows you to increase bandwidth and availability by using a group of ports to carry traffic in parallel between switches. Load sharing, link aggregation, and trunking are terms that have been used interchangeably in Extreme Networks documentation to refer to the same feature, which allows multiple physical ports to be aggregated into one logical port, or link aggregation group (LAG). Refer to IEEE 802.3ad for more information on this feature. The advantages to link aggregation include an increase in bandwidth and link redundancy. NOTE
All ports in a LAG must be running at the same speed and duplex setting. Each port can belong to only one LAG.

Load sharing allows the switch to use multiple ports as a single logical port, or LAG. For example, VLANs see the LAG as a single logical port. And, although you can only reference the master port of a LAG to a Spanning Tree Domain (STPD), all the ports of the LAG actually belong to the specified STPD. Most load-sharing algorithms guarantee packet sequencing between clients. Link aggregation, or load sharing, is disabled by default. If a port in a load-sharing group (or LAG) fails, traffic is redistributed to the remaining ports in the LAG. If the failed port becomes active again, traffic is redistributed to include that port.

NOTE
Load sharing must be enabled on both ends of the link, or a network loop may result.

Link aggregation is most useful when:


The egress bandwidth of traffic exceeds the capacity of a single link. Multiple links are used for network resiliency.

In both situations, the aggregation of separate physical links into a single logical link multiplies total link bandwidth in addition to providing resiliency against individual link failures. In modular switches, ExtremeWare XOS supports LAGs across multiple modules, so resiliency is also provided against individual module failures. The software supports control protocols across the LAGs, both static and dynamic. If you add the protocols (for example, EAPS, ESRP, and so forth) to the port and then create a LAG on that port, you may experience a slight interruption in the protocol operation. In order to seamlessly add or delete bandwidth when running control protocols, Extreme Networks recommends that you create a LAG consisting of only one port. Then add your protocols to that port and add other ports as needed. VMAN ports can belong to LAGs. If any port in the LAG is enabled for VMAN, all ports in the group are automatically enabled to handle jumbo size frames on the BlackDiamond 10K switch; you must enable jumbo frames on the BlackDiamond 8800 family of switches and the Summit X450 switch. Also, VMAN is automatically enabled on all ports of the untagged LAG. You can run the Link Layer Discovery Protocol (LLDP) on ports in a LAG.

ExtremeWare XOS 11.3 Concepts Guide

119

Configuring Slots and Ports on a Switch

Link Aggregation and Software-Controlled Redundant Ports Summit X450 Switch Only
If you are configuring software-controlled redundant ports and link aggregation together, the following rules apply:

Only the master logical port can be a either a primary or redundant port. You must unconfigure the software-controlled redundant ports prior to either configuring or unconfiguring load sharing. The entire LAG must go down before the software-controlled redundant port takes effect.

Dynamic versus Static Load Sharing


Beginning with 11.3, ExtremeWare XOS software supports two broad categories of load sharing, or link aggregation:

Dynamic load sharingDynamic load sharing is a grouping of ports that use the Link Aggregation Control Protocol (LACP) to dynamically determine if link aggregation is possible and then to automatically configure the aggregation. LACP is part of the IEEE 802.3ad standard and allows the switch to dynamically reconfigure the link aggregation groups (LAGs). The LAG is enabled only when LACP detects that the remote device is also using LACP and is able to join the LAG. Static load sharingStatic load sharing is a grouping of ports specifically configured to load share. The switch ports at each end must be specifically configured as part of a load-sharing group. NOTE

The platform-related load-sharing algorithms apply to LACP (as well as static load sharing).

Load-Sharing Algorithms
With ExtremeWare XOS version 11.2, you can use IPv6 addresses in the load-sharing algorithms. Load-sharing, or link aggregation, algorithms allow you to select the distribution technique used by the LAG to determine the output port selection. Algorithm selection is not intended for use in predictive traffic engineering. The ExtremeWare XOS software supports static load sharing, which is a grouping of ports specifically configured to load share. Beginning with ExtremeWare XOS version 11.3, the software also supports dynamic load sharing. (See LACPDynamic Link Aggregation on page 122 for complete information on LACP.) The switch ports at each end must be configured as part of a load-sharing group. Additionally, you can choose the load-sharing algorithm used by the group. The dynamic load-sharing feature, or Link Aggregation Control Protocol (LACP), is standards-based and compatible with most third-party switches. Static load sharing is also compatible with most thirdparty switches.

NOTE
Always reference the master logical port of the load-sharing group when configuring or viewing VLANs. VLANs configured to use other ports in the LAG will have those ports deleted from the VLAN when link aggregation is enabled.

120

ExtremeWare XOS 11.3 Concepts Guide

Link Aggregation on the Switch

Link Aggregation Algorithm on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch
NOTE
You cannot configure port-based load sharing on the BlackDiamond 8800 family of switches or the Summit X450 switch.

Address-based load sharing. When you configure address-based load sharing, the switch examines a specific place in the packet to determine which egress port to use for forwarding traffic:

For Layer 2 load sharing, the switch uses the MAC source address and destination address. For Layer 3 load sharing, the switch uses the IP source address and destination address.

You control the field examined by the switch for address-based load sharing when the load-sharing group is created by using the following command:
enable sharing {<master_port>} grouping <port_list> {algorithm address-based [L2 | L3]}

If the packet is not IP, the switch applies the Layer 2 algorithm, which is the default setting.

Link Aggregation Algorithms on the BlackDiamond 10K Switch


You can configure one of two load-sharing, or link aggregation, algorithms on the BlackDiamond 10K switch, as follows:

Port-basedUses the ingress port to determine which physical port in the load-sharing group is used to forward traffic out of the switch. Address-basedUses addressing information to determine which physical port in the load-sharing group to use to forward traffic out of the switch. Addressing information is based on the packet protocol, as follows:

IP packetsUses the source and destination MAC and IP addresses and the TCP port number. All other packetsUses the source and destination MAC address.

If you do not explicitly select an algorithm, the port-based scheme is used. However, the address-based algorithm has a more even distribution and is the recommended choice. Address-based load sharing. When you configure address-based load sharing, the switch examines a specific place in the packet to determine which egress port to use for forwarding traffic:

For Layer 2 load sharing, the switch uses the MAC source address and destination address. For Layer 3 load sharing, the switch uses the IP source address and destination address. For Layer 4 load sharing, the switch using the TCP source and destination port number.

You can control the field examined by the switch for address-based load sharing by using the following command:
configure sharing address-based [L2 | L2_L3 | L2_L3_L4 | L2_L3_CHK_SUM | L2_L3_L4_CHK_SUM]

where CHK SUM indicates that the switch should examine the IP check sum. Examining the IP check sum in addition to the other parameters produces a random traffic pattern on the egress of the load-

ExtremeWare XOS 11.3 Concepts Guide

121

Configuring Slots and Ports on a Switch sharing links because the IP check sum includes the packet length, which is likely to change from packet to packet. NOTE
Those variables with CHK_SUM apply only to IPv4 packets.

This feature is available only for the address-based load-sharing algorithm. The selected address-based algorithm is applied to the entire switch, to all the load-sharing groups configured as address-based. Layer 2 is the default setting. The master port of the load-sharing group can be the monitor port for port-mirroring.

LACPDynamic Link Aggregation


Beginning with ExtremeWare XOS version 11.3, you can run the Link Aggregation Control Protocol (LACP) on Extreme Networks devices. LACP enables dynamic load sharing and hot standby for link aggregation links, in accordance with the IEEE 802.3ad standard. All third-party devices supporting LACP run with Extreme Networks devices. The addition of LACP provides the following enhancements to static load sharing, or link aggregation:

Automatic configuration Rapid configuration and reconfiguration Deterministic behavior Low risk of duplication or misordering

Once you enable load-sharing, the LACP protocol is enabled by default. You configure dynamic link aggregation by first assigning a primary, or logical, port to the group, or LAG and then specifying the other ports you want in the LAG. LACP, using an automatically generated key, determines which links can aggregate. Each link can belong to only one LAG. LACP determines which links are available. The communicating systems negotiate priority for controlling the actions of the entire trunk (LAG), using LACP, based on the lowest system MAC number. You can override this automatic prioritization by configuring the system priority for each LAG. Once you enable and configure LACP, the system sends PDUs (LACPDUs) on the LAG ports. The LACPDUs inform the remote system of the identity of the sending system, the automatically generated key of the link, and the desired aggregation capabilities of the link. If a key from a particular system on a given link matches a key from that system on another link, those links are aggregatable. Once the remote system exchanges LACPDUs with the LAG, the system determines the status of the ports and whether to send traffic on which ports. Among those ports deemed aggregatable by LACP, the system uses those ports with the lowest port number as active ports; the remaining ports aggregatable to that LAG are put into standby status. Should an active link fail, the standby ports become active, also according to the lowest port number. (See Configuring LACP on page 124 for the number of active and standby LACP links supported per platform.)

122

ExtremeWare XOS 11.3 Concepts Guide

Link Aggregation on the Switch All ports configured in a LAG begin in an unselected state. Based on the LACPDUs exchanged with the remote link, those ports that have a matching key are moved into a selected state. If there is no matching key, the ports in the LAG remain in the unselected state. However if more ports in the LAG are selected than the aggregator can handle because of the system hardware, those ports that fall out of the hardwares capability are moved into standby state. As the name implies, these ports are available to join the aggregator if one of the selected ports should go offline. Once the ports in the LAG move into the selected state, LACP uses the mux portion of the protocol to determine which ports join the aggregator and can collect and distribute traffic. A few seconds after a port is selected, it moves into the mux state of waiting, and then into the mux state of attached. The attached ports then send their own LACP sync messages announcing that they are ready to receive traffic. The protocol keeps sending and receiving LACPDUs until both sides of the link have echoed back each others information; the ends of the link are then considered synchronized. Once the sync messages match up on each end, that port is moved into the aggregator (into the mux state of collectingdistributing) and is able to collect and distribute traffic. The protocol then enables the aggregated link for traffic and monitors the status of the links for changes that may require reconfiguration. For example, if one of the links in a LAG goes down and there are standby links in that LAG, LACP automatically moves the standby port into selected mode and that port begins collecting and distributing traffic. The marker protocol portion of LACP ensures that all traffic on a link has been received in the order in which it was sent and is used when links must be dynamically moved between aggregation groups. The Extreme Networks LACP implementation responds to marker frames but does not initiate these frames.

NOTE
Always verify the LACP configuration by issuing the show ports sharing command; look for the ports listed as being in the aggregator.

Configuring Switch Load Sharing


To set up a switch for load sharing, or link aggregation, among ports, you must create a load-sharing group of ports, also known as a link aggregation group (LAG). The first port in the load-sharing group is configured to be the master logical port. This is the reference port used in configuration commands and serves as the LAG group ID. It can be thought of as the logical port representing the entire port group. All the ports in a load-sharing group must have the same exact configuration, including autonegotiation, duplex setting, ESRP host attach or dont-count, and so on. All the ports in a loadsharing group must also be of the same bandwidth class. To define a load-sharing group, or LAG, you assign a group of ports to a single, logical port number. To enable or disable a load-sharing group, use the following commands:
enable sharing <port> grouping <port_list> {algorithm [port-based | address-based {L2|L3}]} {lacp} disable sharing <port>

ExtremeWare XOS 11.3 Concepts Guide

123

Configuring Slots and Ports on a Switch

Adding and Deleting Ports in a Load-Sharing Group


Ports can be added or deleted dynamically in a load-sharing group, or LAG. To add or delete ports from a load-sharing group, use the following commands:
configure sharing <port> add ports <port_list> configure sharing <port> delete ports <port_list>

Configuring Load Sharing on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch
The following rules apply to load sharing on the BlackDiamond 8800 family of switches and the Summit X450 switch:

One static LAG can contain up to 8 ports. The maximum number of LAGs is 32. Any broadcast, multicast, or unknown unicast packet is transmitted on a single port of a LAG. You can configure only the address-based load-sharing algorithm. The default load-sharing algorithm is L2 address-based aggregation. NOTE

See Configuring LACP on page 124 for the maximum number of links, selected and standby, per LACP.

Configuring Load Sharing on the BlackDiamond 10K Series of Switches


The following rules apply to load sharing on the BlackDiamond 10K series of switches:

One static LAG can contain up to 16 ports. The maximum number of LAGs is 128. You cannot specify L2 or L3 address-based load sharing. The default load-sharing algorithm is port-based aggregation. NOTE

See Configuring LACP on page 124 for the maximum number of links, selected and standby, per LACP.

Load Sharing Rules and Restrictions for All Switches


Additionally, the following rules apply to load sharing on all switches:

The ports in the LAG do not need to be contiguous. A LAG that spans multiple modules must use ports that have the same maximum bandwidth capability, with one exceptionyou can mix media type on 1 Gbps ports.

Configuring LACP
To configure LACP, or dynamic link aggregation, you must, again, first create a LAG. The first port in the LAG serves as the logical port for the LAG. This is the reference port used in configuration

124

ExtremeWare XOS 11.3 Concepts Guide

Link Aggregation on the Switch commands. It can be thought of as the logical port representing the entire port group, and it serves as the LAG Group ID. To create a LAG for LACP, issue the following command, take the following steps: 1 Create a LAG, using the following command: enable sharing <port> grouping <port_list> {algorithm [port-based | address-based {L2|L3}]} {lacp} The port you assign using the first parameter becomes the logical port for the link aggregation group and the LAG Group ID when using LACP. This logical port must also be included in the port list of the grouping itself. 2 If you wish to override the default prioritization in LACP for a specified LAG, issue the following command:
configure sharing <port> lacp system-priority <priority>

This step is optional; LACP handles prioritization using system MAC addresses. 3 Add or delete ports to the LAG as desired, using the following commands:
configure sharing <port> add ports <port_list> configure sharing <port> delete ports <port_list>

NOTE
Always verify the LACP configuration by issuing the show ports sharing command; look for the ports listed as being in the aggregator.

Configuring LACP on BLackDiamond 8800 Family of Switches and Summit X450 Switch. The following rules apply to the number of LACP ports in one LAG on the BlackDiamond 8800 family of switches and on the Summit X450 switch:

Up to 16 link per LAG Up to 8 selected links and 8 standby links Only address-based LACP algorithm

Configuring LACP on BLackDiamond 10K Series of Switches. The following rules apply to the number of LACP ports in one LAG on the BlackDiamond 10K series of switches:

Up to 32 link per LAG Up to 16 selected links and 16 standby links Cannot specify L2 or L3 address-based LACP algorithm

Load-Sharing Examples
This section provides examples of how to define load sharing, or link aggregation, on stand-alone and modular switches, as well has defining dynamic link aggregation.

Load Sharing on a Stand-alone Switch


The following example defines a static load-sharing group that contains ports 9 through 12, and uses the first port in the group as the master logical port 9:
enable sharing 9 grouping 9-12

ExtremeWare XOS 11.3 Concepts Guide

125

Configuring Slots and Ports on a Switch In this example, logical port 9 represents physical ports 9 through 12. When using load sharing, you should always reference the master logical port of the load-sharing group (port 9 in the previous example) when configuring or viewing VLANs; the logical port serves as the LAG Group ID. VLANs configured to use other ports in the load-sharing group will have those ports deleted from the VLAN when load sharing becomes enabled.

Cross-Module Load Sharing on a Modular Switch


The following example defines a static load-sharing group on modular switches that contains ports 9 through 12 on slot 3, ports 7 through 10 on slot 5, and uses the port 9 in the slot 3 group as the primary logical port, or LAG Group ID:
enable sharing 5:7 grouping 3:9-3:12, 5:7-5:10

In this example, logical port 5:7 represents physical ports 3:9 through 3:12 and 5:7 through 5:10. When using load sharing, you should always reference the LAG Group ID of the load-sharing group (port 3:9 in the previous example) when configuring or viewing VLANs. VLANs configured to use other ports in the load-sharing group will have those ports deleted from the VLAN when load sharing becomes enabled. Address-based load sharing can also span modules.

Single-Module Load Sharing on a Modular Switch


The following example defines a static load-sharing, or link aggregation, group that contains ports 9 through 12 on slot 3 and uses the first port as the master logical port 9, or LAG group ID:
enable sharing 3:9 grouping 3:9-3:12

In this example, logical port 3:9 represents physical ports 3:9 through 3:12.

LACP Example
The following configuration example:

Creates a dynamic LAG with the logical port (LAG Group ID) of 10 that contains ports 10 through 12. Sets the system priority for that LAG to 3. Adds port 5 to the LAG.

enable sharing 10 grouping 10-12 lacp configure sharing 10 lacp system-priority 3 configure sharing 10 add port 5

Displaying Switch Load Sharing


Beginning with ExtremeWare XOS version 11.3, you can use either static or dynamic load sharing (link aggregation). LACP is used to create, configure, and display dynamic link aggregation. In the link aggregation displays, the types are shown by the following aggregation controls:

Static link aggregationstatic

126

ExtremeWare XOS 11.3 Concepts Guide

Link Aggregation on the Switch

Dynamic link aggregationLACP

To verify your configuration, use the following command:


show ports sharing

The following is an example of the display you see when you display load sharing, or link aggregation, on the Summit X450 switch:
Load Sharing Monitor Config Current Agg Ld Share Ld Share Agg Link Link Up Master Master Control Algorithm Group Mbr Status transitions ============================================================================== 5 5 LACP L2 5 Y A 3 L2 6 Y A 3 L2 7 Y A 3 L2 8 Y A 3 L2 9 A 3 L2 10 A 3 12 Static L2 12 R 0 L2 13 R 0 =========================================================================== Link Status: A-Active, D-Disabled, R-Ready, NP-Port not present Load Sharing Algorithm: (L2) Layer 2 address based, (L3) Layer 3 address based Default algorithm: L2 Number of load sharing trunks: 2

NOTE
The Agg Mbr column displays which ports in the LACP LAG are added to the aggregator at the hardware level. Only those ports that are added to the aggregator actually send and receive traffic. The Y means the port is added to the aggregator.

To verify LACP configuration, issue the following command: show lacp The following is an example of the output you see when you display the LACP information on the modular switch:
LACP Up LACP Enabled System MAC LACP PDUs dropped on non-LACP ports Lag : : : : Yes Yes 00:04:96:10:33:60 0

Actor Actor Partner Partner Partner Agg Sys-Pri Key MAC Sys-Pri Key Count -------------------------------------------------------------------------------2:1 90 0x07d1 00:01:30:f9:9c:30 601 0x1391 2 4:5 100 0x0fa5 00:01:30:f9:9c:30 321 0x1f47 16 4:9 677 0x0fa9 00:01:30:f9:9c:30 87 0x0fa9 8

To display information for the specified LAG, issue the following command: show lacp lag <group-id> {detail} The following is an example of the output you see when you display the LACP information for this command on a modular switch:

ExtremeWare XOS 11.3 Concepts Guide

127

Configuring Slots and Ports on a Switch


Lag Actor Actor Partner Partner Partner Agg Sys-Pri Key MAC Sys-Pri Key Count -------------------------------------------------------------------------------4:5 100 0x0fa5 00:01:30:f9:9c:30 321 0x1f47 16 Port list: Member Rx Sel Mux Actor Partner Port State Logic State Flags Port -------------------------------------------------------------------------------4:5 Current Selected Collect-Dist A-GSCD-- 8015 4:6 Current Selected Collect-Dist A-GSCD-- 8016 4:7 Current Selected Collect-Dist A-GSCD-- 8017 4:8 Current Selected Collect-Dist A-GSCD-- 8019 4:25 Current Selected Collect-Dist A-GSCD-- 8020 ================================================================================ Actor Flags: A-Activity, T-Timeout, G-Aggregation, S-Synchronization C-Collecting, D-Distributing, F-Defaulted, E-Expired

The following is an example of the output you see when you add the detail parameter for LAG 1 on a modular switch:
show lacp lag 1 detail Lag Actor Actor Partner Partner Partner Agg Sys-Pri Key MAC Sys-Pri Key Count -------------------------------------------------------------------------------4:5 100 0x0fa5 00:01:30:f9:9c:30 321 0x1f47 16 Up : Yes Enabled : Yes Unack count : 0 Wait-for-count : 0 Receive state : Enabled Transmit state : Enabled Selected count : 16 Standby count : 0 LAG Id flag : Yes S.pri:100 , S.id:00:04:96:10:33:60, K:0x0fa5 T.pri:321 , T.id:00:01:30:f9:9c:30, L:0x1f47 Port list: Member Rx Sel Mux Actor Partner Port State Logic State Flags Port -------------------------------------------------------------------------------4:5 Current Selected Collect-Dist A-GSCD-- 8015 4:6 Current Selected Collect-Dist A-GSCD-- 8016 4:7 Current Selected Collect-Dist A-GSCD-- 8017 4:8 Current Selected Collect-Dist A-GSCD-- 8019 4:25 Current Selected Collect-Dist A-GSCD-- 8020 ================================================================================ Actor Flags: A-Activity, T-Timeout, G-Aggregation, S-Synchronization C-Collecting, D-Distributing, F-Defaulted, E-Expired

To display LACP information for a specific port that is a member of a LAG, issue the following command: show lacp member-port <port> {detail}

128

ExtremeWare XOS 11.3 Concepts Guide

Switch Port Mirroring The following is an example of the output you see when you display the LACP information for port 5 on the Summit X450 switch:
Member Rx Sel Mux Actor Partner Port State Logic State Flags Port -------------------------------------------------------------------------------5 Current Selected Collect-Dist A-GSCD-- 1005 ================================================================================ Actor Flags: A-Activity, T-Timeout, G-Aggregation, S-Synchronization C-Collecting, D-Distributing, F-Defaulted, E-Expired

The following is an example of the output you see when you add the detail parameter for port 5 on the Summit X450 switch:
Member Rx Sel Mux Actor Partner Port State Logic State Flags Port -------------------------------------------------------------------------------5 Current Selected Collect-Dist A-GSCD-- 1005 Up : Yes Enabled : Yes Link State : Up Ready_N : Yes Wait pending : No Ack pending : No LAG Id: S.pri:0 , S.id:00:04:96:1f:a5:2e, K:0x03ed, P.pri:0 , P.num:1005 T.pri:0 , T.id:00:04:96:1f:a5:76, L:0x03ed, Q.pri:0 , Q.num:1005 Stats: Rx - Accepted : 13980 Rx - Dropped due to error in verifying PDU : 0 Rx - Dropped due to LACP not being up on this port : 0 Rx - Dropped due to matching own MAC : 0 Tx - Sent successfully : 13979 Tx - Transmit error : 0 ================================================================================ Actor Flags: A-Activity, T-Timeout, G-Aggregation, S-Synchronization C-Collecting, D-Distributing, F-Defaulted, E-Expired

Refer to Displaying Port Configuration Information for information on displaying summary loadsharing information. To clear the counters, issue the following command:
clear lacp counters

Switch Port Mirroring


NOTE
Beginning with ExtremeWare XOS software version 11.2, you can accomplish port mirroring using ACLs or CLEARFlow. See Chapter 13 for more information on ACLs and Chapter 18 for more information on CLEAR-Flow.

ExtremeWare XOS 11.3 Concepts Guide

129

Configuring Slots and Ports on a Switch Port mirroring configures the switch to copy all traffic associated with one or more ports. The monitor port can then be connected to a network analyzer or RMON probe for packet analysis. The system uses a traffic filter that copies a group of traffic to the monitor port. You can have only one monitor port on the switch. Up to 16 mirroring filters and 1 monitor port can be configured.

NOTE
On the BlackDiamond 8800 family of switches and the Summit X450 switch, you can mirror only 8 VLANs on a given port.

Switch port mirroring is disabled by default.

NOTE
Frames that contain errors are not mirrored.

Switch Port Mirroring on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
The traffic filter on the BlackDiamond 8800 family of switches and the Summit X450 switch can be defined based on one of the following criteria:

Physical portAll data that traverses the port, regardless of VLAN configuration, is copied to the monitor port. You can specify which traffic the port mirrors:

IngressMirrors traffic received at the port. EgressMirrors traffic sent from the port. Ingress and egressMirrors all traffic forwarded by the port. (If you omit the optional parameters, all traffic is forwarded; the default for port-based mirroring is ingress and egress).

VLANAll data to a particular VLAN, regardless of the physical port configuration, is copied to the monitor port. Virtual portAll data specific to a VLAN on a specific port is copied to the monitor port. Only 8 VLANs can be mirrored on a given physical port. Only traffic ingressing a VLAN can be monitored; you cannot specify ingressing or egressing traffic when mirroring VLAN traffic. When routing between VLANs, ingress mirrored traffic is presented to the monitor port as modified for routing. When you specify the ingress traffic, the packet is mirrored after it is modified by the ingress process and may include internal tagging and/or egress tagging. Even if you select ingress and egress traffic, the packet is mirrored only the first time it matches a mirror filter and is not mirrored on subsequent configured filters. You cannot include the monitor port for the BlackDiamond 8800 family of switches or a Summit X450 switch in a load-sharing group. You cannot run sFlow and mirroring on the same switch. If you attempt to enable mirroring on a switch that is already enabled for sFlow, the switch returns the following message:

130

ExtremeWare XOS 11.3 Concepts Guide

Switch Port Mirroring


Mirroring is not compatible with SFlow. Mirroring is not enabled!

All traffic egressing the monitor port is tagged on the BlackDiamond 8800 family of switches and the Summit X450 switch. Even if some untagged ports send mirrored traffic to the monitor port, that traffic also egresses the monitor port tagged with the internal VLAN ID.

Switch Port Mirroring on the BlackDiamond 10K Switch Only


The traffic filter on the BlackDiamond 10K switch can be defined based on one of the following criteria:

Physical portAll data that traverses the port, regardless of VLAN configuration, is copied to the monitor port. VLANAll data to and from a particular VLAN, regardless of the physical port configuration, is copied to the monitor port. Virtual portAll data specific to a VLAN on a specific port is copied to the monitor port. The master port of the load-sharing group can be the monitor port for port-mirroring. You cannot run sFlow and mirroring on the same port. If you attempt to enable mirroring on a port that is already enabled for sFlow, the switch returns the following message:
Mirroring is not compatible with SFlow. Mirroring is not enabled!

The monitor port transmits tagged or untagged frames, according to the way you configured the monitor port. This feature allows you to mirror multiple ports or VLANs to a monitor port, while preserving the ability of a single protocol analyzer to track and differentiate traffic within a broadcast domain (VLAN) and across broadcast domains (for example, across VLANs when routing).

NOTE
The monitor port on the BlackDiamond 10K switch must be explicitly configured for tagged or untagged frames beginning with ExtremeWare XOS version 11.0.

The traffic egressing the monitor port can be either tagged or untagged. If the mirroring is enabled as tagged on the monitor port, all traffic egressing the monitor port is tagged. In this case, even if some untagged ports send mirrored traffic to the monitor port, that traffic also egresses the monitor port as tagged. And, if mirroring is enabled as untagged on the monitor port, all traffic egressing the monitor port is untagged, including mirrored tagged packets. When you upgrade to ExtremeWare XOS 11.0 on the BlackDiamond 10K switches, all restored mirroring configurations are tagged on the monitor ports.

Switch Port-Mirroring Rules and Restrictions for All Switches


This section summarizes the rules and restrictions for configuring switch port mirroring:

When you disable mirroring, all the filters are unconfigured. To change monitor ports, you must first remove all the filters. You cannot mirror the monitor port. The mirroring configuration is removed when you:

Delete a VLAN (for all VLAN-based filters). Delete a port from a VLAN (for all VLAN-, port-based filters).

ExtremeWare XOS 11.3 Concepts Guide

131

Configuring Slots and Ports on a Switch


Unconfigure a slot (for all port-based filters on that slot).

Any mirrored port can also be enabled for load sharing (or link aggregation); however, each individual port of the load-sharing group must be explicitly configured for mirroring. The monitor port is automatically removed from all VLANs; you cannot add it to a VLAN. The mirroring filters are not confined to a single module; they can have ports that span multiple modules. You cannot use the management port at all in switch port-mirroring configurations.

Switch Port-Mirroring Examples


The following example removes all port-mirroring configuration from the switch:
disable mirroring

NOTE
When you change the mirroring configuration, the switch stops sending egress packets from the monitor port until the change is complete. The ingress mirroring traffic to the monitor port and regular traffic are not affected.

The BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
The following example selects slot 3, port 4 on a modular switch as the monitor port and sends all traffic received at slot 6, port 5 to the monitor port:
enable mirroring to port 3:4 configure mirroring add port 6:5 ingress

The following example selects slot 3, port 4 on a modular switch as the monitor port and send all traffic sent from slot 6, port 5 to the monitor port:
enable mirroring to port 3:4 configure mirroring add port 6:5 egress

The following example selects port 4 on a standalone switch as the monitor port and sends all traffic ingressing the VLAN red to the monitor port:
enable mirroring to port 4 configure mirroring add vlan red

The following example selects port 4 on a standalone switch as the monitor port and sends all traffic ingressing the VLAN red on port 5 to the monitor port:
enable mirroring to port 4 configure mirroring add vlan red port 5

BlackDiamond10K Switch Only


The following example selects slot 7, port 3 as the untagged monitor port, and sends all traffic coming into or out of a modular switch on slot 7, port 1 to the monitor port:
enable mirroring to port 7:3 untagged configure mirroring add port 7:1

132

ExtremeWare XOS 11.3 Concepts Guide

Extreme Discovery Protocol The following example sends all traffic coming into or out of the system on slot 8, port 1 and the VLAN default to the untagged monitor port, which is slot 7, port 3:
enable mirroring to port 7:3 untagged configure mirroring add port 8:1 vlan default

Verifying the Switch Port-Mirroring Configuration


The screen output resulting from the show mirroring command lists the ports that are involved in mirroring and which is the monitor port. The display differs slightly depending on the platform.

Displaying Switch Port-Mirroring Configuration on the BlackDiamond 8800 Family of Switches


Following is sample output from the show lacp command on the BlackDiamond 8810 switch:
Mirror port: 3:15 is up Number of Mirroring filters: 3 Mirror Port configuration: Port number 3:12 in all vlans ingress only Port number 5:4 in all vlans egress only Port number 8:30 in all vlans

Displaying Switch Port-Mirroring Configuration on the Summit X450 Switch


Following is sample output from the show lacp command on the Summit X450 switch:
Mirror port: 12 is down Number of Mirroring filters: 1 Mirror Port configuration: Port number 4 in vlans peggy

Displaying Switch Port-Mirroring Configuration on the BlackDiamond 10K Switch


Following is sample output from the show lacp command on the BlackDiamond 10K switch:
Mirror port: 1:5 is up tagged Number of Mirroring filters: 1 Mirror Port configuration: Port number 2:1 in all vlans

Extreme Discovery Protocol


The Extreme Discovery Protocol (EDP) is used to gather information about neighbor Extreme Networks switches. EDP is used to by the switches to exchange topology information. Information communicated using EDP includes:

Switch MAC address (switch ID) Switch software version information Switch IP address

ExtremeWare XOS 11.3 Concepts Guide

133

Configuring Slots and Ports on a Switch


Switch VLAN IP information Switch port number Switch configuration data: duplex and speed

EDP is enabled on all ports by default. EDP enabled ports advertise information about the Extreme Networks switch to other switches on the interface and receives advertisements from other Extreme Networks switches. Information about other Extreme Networks switches is discarded after a timeout interval is reached without receiving another advertisement. To disable EDP on one or more ports, use the following command:
disable edp ports [<ports> | all]

To enable EDP on specified ports, use the following command:


enable edp ports [<ports> | all]

To clear EDP counters on the switch, use the following command:


clear lacp counters

This command clears the following counters for EDP protocol data units (PDUs) sent and received per EDP port:

Switch PDUs transmitted VLAN PDUs transmitted Transmit PDUs with errors Switch PDUs received VLAN PDUs received Received PDUs with errors

To view EDP port information on the switch, use the following command:
show edp

The following is sample output from the show edp command (the screen display was interrupted in the following sample) on a modular switch:
EDP advert-interval EDP holddown-interval EDP enabled on ports 1 1:22 1:23 2:10 9 0 1 2:20 2:21 2:31 2:32 2:42 2:33 2:34 2:35 2:36 2:37 2:38 2:39 2:40 2:4 2:22 2:23 2:24 2:25 2:26 2:27 2:28 2:29 2:3 1:24 2:11 2:1 2:2 2:3 2:4 2:5 2:6 2:12 2:13 2:14 2:15 2:16 2:7 2:8 2:9 2:17 2:18 2:1 :60 seconds :180 seconds :1:1 1:2 1:3 1:4 1:5 1:6 1:12 1:13 1:14 1:15 1:16

1:7 1:8 1:9 1:10 1:11 1:17 1:18 1:19 1:20 1:2

Additionally, you view EDP information by using the following command:


show edp port <ports> detail

The following is sample output from the show edp ports 1:1 detail command on a modular switch:

134

ExtremeWare XOS 11.3 Concepts Guide

Software-Controlled Redundant Port and Smart Redundancy


============================================================================= Port 1:1: EDP is Enabled Tx stats: sw-pdu-tx=2555 Rx stats: sw-pdu-rx=2511

vlan-pdu-tx=1465 vlan-pdu-rx=2511

pdu-tx-err=0 pdu-rx-err=0

Time of last transmit error: None Time of last receive error: None Remote-System: BD10K Age = 41 Remote-ID: 00:00:00:30:48:41:ed:97 Software version: 11.1.0.19 Remote-Port: 1:1 Port Type: Ethernet Auto Negotiation: OFF Flow Control: SYMMETRIC/ASYMMETRIC Duplex Speed: Configured = HALF Actual = HALF Port Speed (MB): Configured = ERROR Actual = 100 Mbps Remote-Vlans: test (4094) Age = 41 =============================================================================

To configure the advertisement interval and the timeout interval, use the following command:
configure edp advertisment-interval <timer> holddown-interval <timeout>

Refer to Displaying Port Configuration Information for information on displaying EDP status.

Software-Controlled Redundant Port and Smart Redundancy


Using the software-controlled redundant port feature you can back up a specified Ethernet port (primary) with a redundant, dedicated Ethernet port; both ports are on the same switch. If the primary port fails, the switch will establish a link on the redundant port and the redundant port becomes active. Only one side of the link must be configured as redundant because the redundant port link is held in standby state on both sides of the link. This feature provides very fast path or network redundancy. NOTE
You cannot have any Layer 2 protocols configured on any of the VLANs that are present on the ports.

Smart Redundancy is a feature that allows control over how the failover from a redundant port to the primary port is managed. If this feature is enabled, which is the default setting, the switch attempts to revert to the primary port as soon as it can be recovered. If the feature is disabled, the switch attempts only to recover the primary port to active if the redundant port fails. A typical configuration of software-controlled redundant ports is a dual-homed implementation (Figure 1). This example maintains connectivity only if the link between switch A and switch B remains open; that link is outside the scope of the software-controlled port redundancy on switch C.

ExtremeWare XOS 11.3 Concepts Guide

135

Configuring Slots and Ports on a Switch

Figure 1: Dual-homed implementation for switch C


Switch A Switch B

Primary Link Switch C

Redundant Link

XOS002

In normal operation, the primary port is active and the software redundant switch (switch C in Figure 1) blocks the redundant port for all traffic, thereby avoiding a loop in the network. If the switch detects that the primary port is down, the switch unblocks the redundant port and allows traffic to flow through that redundant port.

NOTE
The primary and redundant ports must have identical VLAN membership.

You configure the software-controlled redundant port feature either to have the redundant link always physically up but logically blocked or to have the link always physically down. The default value is to have the link physically down, or Off. By default, Smart Redundancy is always enabled. If you enable Smart Redundancy, the switch automatically fails over to the redundant port and returns traffic to the primary port once connectivity is restored on that port. If you do not want the automatic restoration of the primary link when it becomes active, disable Smart Redundancy.

Guidelines for Software-Controlled Redundant Ports and Port Groups


Software-controlled redundant ports and port groups have the following limitations:

You cannot have any Layer 2 protocols configured on any of the VLANs that are present on the ports. (You will see an error message if you attempt to configure software redundant ports on ports with VLANs running Layer 2 protocols.) The primary and redundant ports must have identical VLAN membership. The master port is the only port of a load-sharing group that can be configured as either a primary or redundant port. Also, all ports on the load-sharing group must fail before the software-controlled redundancy is triggered. You must disable the software redundancy on the master port prior to enabling or disabling load sharing. You can configure only one redundant port for each primary port. Recovery may be limited by FDB aging on the neighboring switch for unidirectional traffic. For bidirectional traffic, the recovery is immediate.

136

ExtremeWare XOS 11.3 Concepts Guide

Software-Controlled Redundant Port and Smart Redundancy

NOTE
On the BlackDiamond 10K switch, 10 Gbps modules with a serial number lower than 804405-00-09 the software redundant port feature cover only those failures where both the TX and RX paths fail. If a single strand of fiber is pulled on these ports, the software redundant port cannot correctly recover from the failure.To display the serial number of the module, issue the show slot <slot_number> command. (All the modules on the BlackDiamond 8800 family of switches have this serial number or higher.)

Configuring Software-Controlled Redundant Ports


When provisioning software-controlled redundant ports, configure only one side of the link as redundant. In Figure 1 only the ports on switch C would be configured as redundant. NOTE
In order to enable the software-controlled redundant port feature the primary and redundant ports must have identical VLAN membership.

To configure a software-controlled redundant port, use the following command:


configure ports <primaryPort> redundant <secondaryPort> {link [on | off]}

The first port specified is the primary port. The second port specified is the redundant port. To unconfigure a software-controlled redundant port, use the following command and enter the primary port(s):
unconfigure ports <port_list> redundant

To configure the switch for the Smart Redundancy feature, use the following command:
enable smartredundancy <port_list>

To disable the Smart Redundancy feature, use the following command:


disable smartredundancy <port_list>

Verifying Software-Controlled Redundant Port Configurations


You can verify the software-controlled redundant port configuration by issuing a variety of CLI commands. To display the redundant ports as well as which are active or members of load-sharing groups, use the following command:
show ports redundant

Sample output from a modular switch looks like the following:


Primary: *1:1 Redundant: 3:1, Link on/off option: OFF Flags: (*)Active, (!) Disabled, (g) Load Share Group

To display information on which ports are primary and redundant software-controlled redundancy ports, use the following command: show ports {mgmt | <port_list>} information {detail}

ExtremeWare XOS 11.3 Concepts Guide

137

Configuring Slots and Ports on a Switch The following is sample output on a modular switch of the show port 1:1 information detail after redundancy is configured:
Virtual-router: VR-Default Type: UTP Random Early drop: Disabled Admin state: Enabled with auto-speed sensing auto-duplex Link State: Active, 100Mbps, full-duplex Link Counter: Up 1 time(s) VLAN cfg: Name: peggy, Internal Tag = 4094, MAC-limit = No-limit STP cfg: Protocol: Name: peggy Protocol: ANY Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported QoS Profile: None configured Queue: QP1 MinBw = 0% MaxBw = QP2 MinBw = 0% MaxBw = QP3 MinBw = 0% MaxBw = QP4 MinBw = 0% MaxBw = QP5 MinBw = 0% MaxBw = QP6 MinBw = 0% MaxBw = QP7 MinBw = 0% MaxBw = QP8 MinBw = 0% MaxBw = Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogIn: Disabled Smart redundancy: Enabled Software redundant port: Enabled Primary: 1:1 Redundant: 3:1 Redundant link configuration: Off Match all protocols.

100% 100% 100% 100% 100% 100% 100% 100%

Pri Pri Pri Pri Pri Pri Pri Pri

= = = = = = = =

1 2 3 4 5 6 7 8

Refer to Displaying Port Configuration Information for more information on the show ports information command.

Configuring Automatic Failover for Combination Ports Summit X450 Switch Only
The Summit X450 switch has 24 gigabit Ethernet ports; you configure automatic failover using the first 4 ports. These ports are called combination ports because either the fiber port or the copper port is active,

138

ExtremeWare XOS 11.3 Concepts Guide

Configuring Automatic Failover for Combination PortsSummit X450 Switch Only but they are never active concurrently. If you plan to use the automatic failover feature, ensure that port settings are set correctly for autonegotiation. Summit X450 ports do not advertise or support flow control frames. NOTE
You may experience a brief episode of the link going down and recovering during the failover.

The redundant ports are shared PHY copper and fiber ports; these are ports 1 to 4 on both the Summit X450-24x and the Summit X450-24t switches. To display the port type currently used as well as the preferred media setting, issue the following command:
show ports {mgmt | <port_list>} information {detail}

Refer to Displaying Port Configuration Information for more information on the show ports information command. The first four fiber ports and the first four 10/100/1000BASE-T ports of the Summit X450 switch are designed as combination ports for uplink redundancy. When sharing ports, only the fiber medium or only the copper medium can be active at one time. See Figure 2 for a diagram of these combination ports on the Summit X450-24t switch and Figure 3 for a diagram of these combination ports on the Summit X450-24x switch. If copper medium 1 goes down while transmitting packets, fiber medium 1 activates and becomes the primary link, and vice-versa.

Figure 2: Redundancy cabling on the Summit X450-24t switch

1 2

3 4

1 2

3 4

S450_004

ExtremeWare XOS 11.3 Concepts Guide

139

Configuring Slots and Ports on a Switch

Figure 3: Redundancy cabling for the SummitX450-24x switch

1 2

3 4

1 2

3 4

S450_005

The switch determines whether the port uses the primary or redundant media based upon the order in which the connectors are inserted into the switch. When the switch senses a mini-GBIC and a copper connector are inserted, the switch enables the uplink redundancy feature. As an example on the Summit X450-24t switch, if you insert mini-GBICs into fiber port 1 and fiber port 3 first and then connect copper ports 1 and 3, the switch assigns ports 1 and 3 as redundant ports. Hardware determines when a link is lost and swaps the primary and redundant ports to maintain stability. After a failover occurs, the switch keeps or sticks with the current port assignment until there is another failure or until a user changes the assignment using the CLI. To change the uplink failover assignment, use the following command:
configure ports <port_list> preferred-medium [copper | fiber] {force}

The default preferred-medium is fiber. If you use the force option, it disables automatic failover. If you force the preferred-medium to fiber and the fiber link goes away, the copper link is not used, even if available.

Displaying Port Configuration Information


You display summary port configuration information using the show ports {mgmt | <port_list>}
configuration {no-refresh}, show ports {mgmt | <port_list>} information {detail},

commands. The show ports configuration command shows you either summary configuration information on all the ports, or more detailed configuration information on specific ports. If you specify the norefresh parameter, the system displays a snapshot of the data at the time you issue the command. The following sample output is from the show ports configuration command on a modular switch and displays the port configuration for all ports:
show ports configuration Port Configuration Port Virtual Port Link Auto Speed Duplex Flow Load Media router State State Neg Cfg Actual Cfg Actual Cntrl Master Primary ================================================================================ 1:1 VR-Default E A ON AUTO 100 AUTO FULL SY/ASYM UTP 1:2 VR-Default E R ON AUTO AUTO UTP 2:1 VR-Default E R ON AUTO AUTO UTP 2:2 VR-Default E R ON AUTO AUTO UTP

140

ExtremeWare XOS 11.3 Concepts Guide

Displaying Port Configuration Information


3:1 3:2 4:1 4:2 5:1 5:2 5:3 5:4 5:5 5:6 5:7 5:8 5:9 5:10 . . . . 5:106 5:107 5:108 VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default VR-Default E E E E E E E E E E E E E E R R R R R R R R R R R R R R ON ON ON ON ON ON ON ON ON ON ON ON ON ON AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO AUTO UTP UTP UTP UTP UTP UTP UTP UTP UTP UTP UTP UTP UTP UTP

VR-Default VR-Default VR-Default

E E E

R R R

ON ON ON

AUTO AUTO AUTO

AUTO AUTO AUTO

UTP UTP UTP

================================================================================ Link Status: A-Active, R-Ready, NP-Port not present Port State: D-Disabled E-Enabled Media: !-Unsupported XENPAK

NOTE
On 10 Gbps ports, the Media Primary column displays NONE when no module is installed, and SR, LR, or ER depending on the module installed when there is one present.

The following sample command displays the port configuration statistics for slot 2, port 2 on a modular switch:
show ports 2:2 configuration

Following is sample output from this command:


Port Configuration Port Virtual Port Link Auto Speed Duplex Flow Load Media router State State Neg Cfg Actual Cfg Actual Cntrl Master Primary ================================================================================ 2:2 VR-Default E R ON AUTO AUTO UTP ================================================================================ Link Status: A-Active, R-Ready, NP-Port not present Port State: D-Disabled E-Enabled Media: !-Unsupported XENPAK

The show ports information command shows you either summary information on all the ports, or more detailed information on specific ports. The output from the command differs very slightly depending on the platform you are using. The following sample output is from the show ports information command and displays the port configuration for a specified port on a modular switch:
QB_Mariner.4 > show port 3:1 info

ExtremeWare XOS 11.3 Concepts Guide

141

Configuring Slots and Ports on a Switch

Port

Link Link Num Num Num Jumbo QOS Load State UPS STP VLAN Proto Size profile Master ================================================================================ 3:1 P Em------e-- ready 0 0 1 1 9216 ================================================================================ Flags : a - Load Sharing Algorithm address-based, D - Port Disabled, e - Extreme Discovery Protocol Enabled, E - Port Enabled, f - Flooding Enabled, g - Egress TOS Enabled, j - Jumbo Frame Enabled, l - Load Sharing Enabled, m - MACLearning Enabled, n - Ingress TOS Enabled, o - Dot1p Replacement Enabled, P - Software redundant port(Primary), q - Background QOS Monitoring Enabled, R - Software redundant port(Redunda nt), s - diffserv Replacement Enabled, r - Load Sharing Algorithm round-robin v - Vman Enabled, f - Unicast Flooding Enabled M - Multicast Flooding Enabled, B - Broadcast Flooding Enable

Diag

Flags

Beginning with ExtremeWare XOS software version 11.3 you can display real-time port utilization information, by issuing the following command:
show ports {mgmt | <port_list>} utilization {bandwidth | bytes | packets}

The following sample output is from the show ports utilization command for all ports on the Summit X450 switch (real-time display that constantly refreshes):
Link Utilization Averages Fri Aug 5 13:23:45 UTC 2005 Port Link Receive Peak Rx Transmit Peak Transmit Status packets/sec packets/sec packets/sec packets/sec ================================================================================ 1 A 0 0 0 0 2 R 0 0 0 0 3 R 0 0 0 0 4 R 0 0 0 0 5 R 0 0 0 0 6 R 0 0 0 0 7 R 0 0 0 0 8 R 0 0 0 0 9 R 0 0 0 0 10 R 0 0 0 0 11 R 0 0 0 0 12 R 0 0 0 0 13 R 0 0 0 0 14 R 0 0 0 0 15 R 0 0 0 0 16 R 0 0 0 0 17 R 0 0 0 0 ================================================================================ Link Status : A-Active, R-Ready, NP-Port Not Present Spacebar->toggle screen U->page up D->page down ESC->exit

142

ExtremeWare XOS 11.3 Concepts Guide

Displaying Port Configuration Information

Port DisplaySummit X450 Switch Only


The following command displays more specific information for port 3 on a Summit X450 switch:
show ports 3 information detail

Following is sample output from this command:


Port: 3 Virtual-router: VR-Default Type: UTP Random Early drop: Disabled Admin state: Enabled with auto-speed sensing auto-duplex Link State: Active, 1 Gbps, full-duplex Link Counter: Up 1 time(s) VLAN cfg: Name: Default, Internal Tag = 1 (MAC-Based), MAC-limit = No-limit STP cfg: s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported Egress Port Rate: 128 Kbps, Max Burst Size: 200 Kb Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: QP3 configured by user Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogin: Enabled NetLogin authentication mode: MAC based NetLogin port mode: MAC based VLANs Smart redundancy: Enabled Software redundant port: Disabled Preferred medium: Fiber

ExtremeWare XOS 11.3 Concepts Guide

143

Configuring Slots and Ports on a Switch

Port DisplayBlackDiamond 8800 Family of Switches Only


The following command displays more specific information for slot 3, port 1 on an BlackDiamond 8810 switch:
show ports 3:1 information detail

Following is sample output from this command:


Port: 3:1 Virtual-router: VR-Default Type: UTP Random Early drop: Disabled Admin state: Enabled with auto-speed sensing auto-duplex Link State: Active, 1 Gbps, full-duplex Link Counter: Up 1 time(s) VLAN cfg: Name: Default, Internal Tag = 1 (MAC-Based), MAC-limit = No-limit STP cfg: s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Match all protocols. Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported Egress Port Rate: 128 Kbps, Max Burst Size: 200 Kb Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: QP3 configured by user Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogin: Enabled NetLogin authentication mode: MAC based NetLogin port mode: MAC based VLANs Smart redundancy: Enabled Software redundant port: Disabled autopolarity: Enabled

144

ExtremeWare XOS 11.3 Concepts Guide

Displaying Port Configuration Information

Port DisplayBlackDiamond 10K Series Switch Only


The switch displays slightly different information for various ports, depending on the speed and media. The following command displays more specific information for a slot 1, port 1 on a BlackDiamond 10K switch:
show ports 1:1 information detail

Following is sample output from this command:


Port: 1:1 Virtual-router: VR-Default Type: UTP Random Early drop: Disabled Admin state: Enabled with auto-speed sensing auto-duplex Link State: Active, 100Mbps, full-duplex Link Counter: Up 1 time(s) VLAN cfg: Name: peggy, Internal Tag = 4094, MAC-limit = No-limit STP cfg: Protocol: Name: peggy Protocol: ANY Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Unicast Flooding: Enabled Multicast Flooding: Enabled Broadcast Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported QoS Profile: None configured Queue: QP1 MinBw = 0% MaxBw = QP2 MinBw = 0% MaxBw = QP3 MinBw = 0% MaxBw = QP4 MinBw = 0% MaxBw = QP5 MinBw = 0% MaxBw = QP6 MinBw = 0% MaxBw = QP7 MinBw = 0% MaxBw = QP8 MinBw = 0% MaxBw = Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogIn: Disabled Smart redundancy: Enabled Software redundant port: Enabled Primary: 1:1 Redundant: 1:2 Redundant link configuration: Off autopolarity: Enabled Match all protocols.

100% 100% 100% 100% 100% 100% 100% 100%

Pri Pri Pri Pri Pri Pri Pri Pri

= = = = = = = =

1 2 3 4 5 6 7 8

ExtremeWare XOS 11.3 Concepts Guide

145

Configuring Slots and Ports on a Switch

146

ExtremeWare XOS 11.3 Concepts Guide

Link Layer Discovery Protocol

This chapter covers the following topics:


Overview on page 147 LLDP Messages on page 148 Managing LLDP on page 150 Supported TLVs on page 150 Configuring LLDP on page 156 Displaying LLDP Settings on page 160

Overview
Beginning with ExtremeWare XOS version 11.2, the software supports the Link Layer Discovery Protocol (LLDP). LLDP is a Layer 2 protocol (IEEE standard 802.1ab) that is used to determine the capabilities of devices such as repeaters, bridges, access points, routers, and wireless stations. ExtremeWare XOS version 11.2 LLDP support enables devices to advertise their capabilities and mediaspecific configuration information and to learn the same information from the devices connected to it. The information is represented in Type Length Value (TLV) format for each data item. The 802.1ab specification provides detailed TLV information. The TLV information is contained and transmitted in an LLDP protocol data unit (LLDPDU). Certain TLVs are mandatory and are always sent once LLDP is enabled; other TLVs are optionally configured. LLDP defines a set of common advertisement messages, a protocol for transmitting the advertisements, and a method for storing the information contained in received advertisements. LLDP provides a standard method of discovering and representing the physical network connections of a given network management domain. LLDP works concurrently with Extreme Discovery Protocol (EDP); it also works independently, you do not have to run EDP to use LLDP. The LLDP neighbor discovery protocol allows you to discover and maintain accurate network topologies in a multivendor environment. The information distributed using LLDP is stored by its recipients in a standard Management Information Base (MIB), making it possible for the information to be accessed by a Network Management System (NMS) using a management protocol such as the Simple Network Management Protocol (SNMP). LLDP transmits periodic advertisements containing device information and media-specific configuration information to neighbors attached to the same network. LLDP agents cannot solicit information from other agents by way of this protocol. The TLV format with link layer control frames is used to communicate with other LLDP agents. LLDP agents also receive link layer control frames, extract the information from TLVs, and store them in LLDP MIB objects. If the information values from the device change at any time, the LLDP agent is notified. The agent then sends an update with the new values, which is referred to as a triggered update. If the information for multiple elements changes in a short period, the changes are bundled together and sent as a single update to reduce network load.

ExtremeWare XOS 11.3 Concepts Guide

147

Link Layer Discovery Protocol You configure LLDP per port, and each port can store received information for a maximum of four neighbors.

NOTE
LLDP runs with load sharing.

LLDP Messages
You configure the device to transmit messages, to receive messages, or both. This section covers the following topics:

LLDP Packets on page 148 Transmitting LLDP Messages on page 149 Receiving LLDP Messages on page 149

LLDP Packets
LLDP is enabled and configured per port. Multiple advertisements messages (or TLVs) are transmitted in one LAN packet, the LLDPDU (Figure 4). The LLDP packet contains the destination multicast address, the source MAC address, the LLDP EtherType, the LLDPDU data, and a frame check sequence (FCS). The LLDP multicast address is defined as 01:80:C2:00:00:0E, and the EtherType is defined as 0x88CC.

Figure 4: LLDP packet format


DA SA Ethertype Data + Pad

LLDP_Multicast Address 6

Source MAC Address 6

88-CC 2

LLDPDU 1500

FCS 4 Octets
XOS005

The following characteristics apply to LLDP packets:


They are IEEE 802.3 Ethernet frames. The frames are sent as untagged frames. The frames are sent with a link-local-assigned multicast address as destination address. The Spanning Tree Protocol (STP) state of the port does not affect the transmission of LLDP frames.

The length of the packet cannot exceed 1500 bytes. As you add TLVs, you increase the length of the LLDP frame. Once you reach 1500 bytes, the remaining TLVs are dropped. Extreme Networks recommends that you advertise information regarding only one or two VLANs on the LLDP port, to avoid dropped TLVs. If the system drops TLVs because of exceeded length, the system logs a message to the EMS and the show lldp statistics commands shows this information under the Tx Length Exceeded field.

148

ExtremeWare XOS 11.3 Concepts Guide

LLDP Messages

NOTE
The LLDPDU has a maximum of 1500 bytes, even with jumbo frames enabled. TLVs that exceed this limit are dropped.

Transmitting LLDP Messages


In transmit mode, the Extreme Networks switch periodically sends out an untagged LLDPDU frame that contains the mandatory LLDP TLVs as well as the configured optional TLVs. The LLDP agent running on the Extreme Networks switch passes serially through the list of ports that are enabled for LLDP and periodically transmits an LLDP frame containing the mandatory TLVs and any configured optional TLVs. The mandatory TLVs and the system description TLV are automatically transmitted once you enable LLDP. The following information, when configured, can be sent at regular intervals:

Chassis ID (mandatory) Port ID (mandatory) Time-to-live (mandatory) Port description System name System description (sent by default) System capabilities Management address 802.1-specific information

VLAN name Port VLAN ID Port and protocol VLAN ID MAC/PHY Power via MDI Link aggregation Maximum frame size

802.3-specific information

This information is obtained from memory objects such as standard MIBs or from system management information.

Receiving LLDP Messages


The LLDP agent running on an Extreme Networks switch receives LLDPDUs, parses the messages, and stores the information in a remote device database. Unrecognized TLVs are also stored in the remote device database, in order of TLV type. The information is purged after the configured timeout interval, unless it is refreshed by the remote LLDP agent. You access the messages from the neighbors with SNMP or the CLI. Each port can store LLDP information from a maximum of four neighbors.

ExtremeWare XOS 11.3 Concepts Guide

149

Link Layer Discovery Protocol

Managing LLDP
LLDP can work in tandem with EDP. LLDP is disabled by default, and EDP is enabled by default. LLDP information is transmitted periodically and stored for a finite period. You access the information using SNMP. A port configured to receive LLDP messages can store information for up to four neighbors. You manage LLDP using the CLI and SNMP. (Refer to ExtremeWare XOS Command Reference Guide for complete information on configuring, managing, and displaying LLDP.) LLDP information is transmitted periodically and stored for a finite period. Once you enable LLDP, you can set a variety of time periods for the transmission and storage of the LLDP messages (or you can use the default values), as follows:

Reinitialization period (default is 2 seconds) Delay between LLDP transmissions (default is 2 seconds)applies to triggered updates, or updates that are initiated by a change in the topology Transmit interval (default is 30 seconds)applies to messages sent periodically as part of protocol Time-to-live (TTL) value (default is 2 minutes)time that the information remains in the recipients LLDP database

Each time a device receives an LLDP advertisement packet, the device stores the information and initializes a timer that is compared to the TTL value of the packet. If the timer reaches the TTL value, the LLDP agent deletes the stored information. This action ensures that only valid information is stored in the LLDP agent. Once you enable LLDP, you can enable the LLDP-specific SNMP traps; the traps are disabled by default. You configure the period between the system sending SNMP notifications; the default interval is 5 seconds. LLDP configurations are saved across reboots when you issue the save configuration command. The system logs EMS messages regarding LLDP when:

Configured optional TLVs that exceed the 1500-byte limit and are dropped. More than 4 neighbors are detected on a port.

When both IEEE 802.1x and LLDP are enabled on the same port, LLDP packets are not sent until one or more clients authenticate a port. Also, incoming LLDP packets are only accepted if one or more clients are authenticated. You can configure an optional TLV to advertise or not to advertise the devices management address information to the ports neighbors. With ExtremeWare XOS, when enabled, this TLV sends out the IPv4 address configured on the management VLAN. If you have not configured an IPv4 address on the management VLAN, the software advertises the systems MAC address. LLDP does not send out IPv6 addresses in this field.

Supported TLVs
The TLVs are contained in the LLDPDU portion of the LLDP packet, and the LLDPDU cannot exceed 1500 bytes. Some TLVs are mandatory according to the 802.1ab standard, and the rest are optional. The mandatory TLVs are included by default as soon as you enable LLDP, as is the system description TLV. One other TLV, system description, is enabled by default on the ExtremeWare XOS LLDP implementation. Additionally some TLVs can be repeated in one LLDP.

150

ExtremeWare XOS 11.3 Concepts Guide

Supported TLVs

NOTE
To avoid exceeding the 1500-byte limit, Extreme Networks recommends sending information on only one or two VLANs on the LLDP port. Any TLVs that exceed the limit are dropped.

The following TLVs are enabled by default when LLDP transmit is enabled on a port:

Chassis ID Port ID Time to live System description End-of-LLDP PDU

All of these TLVs that are sent by default are mandatory for the protocol and cannot be disabled, except the system description. You can configure the system not to advertise the system description when LLDP is enabled; the other four TLVs cannot be configured not to advertise. Table 18 lists all the defined TLVs, if they are included by default once you enable LLDP, if they can be configured, if they are mandatory or optional, and if you can repeat that TLV in one LLDP packet.

NOTE
Refer to ExtremeWare XOS Command Reference Guide for complete information on configuring LLDP using the CLI.

Table 18: Available TLVs


Name Chassis ID Port ID Time to live (TTL) Port description System name System description System capabilities Management address VLAN name Port VLAN ID Port and protocol VLAN ID Protocol identity MAC/PHY configuration/ status Power via MDI Link aggregation Maximum frame size End-of-LLDP PDU X X X X X Mandatory TLV X Included by default X X X X X X X X X X X X X Not supported X X ExtremeWare XOS sends only 1 TLV User configurable Repeatable Comments Mandatory TLV Mandatory TLV Mandatory TLV

ExtremeWare XOS 11.3 Concepts Guide

151

Link Layer Discovery Protocol

Mandatory TLVs
This section discusses the following mandatory TLVs, which are automatically enabled once you enable LLDP on a port:

Chassis ID TLV on page 152 Port ID TLV on page 152 TTL TLV on page 152 End-of-LLDPDU TLV on page 152

Chassis ID TLV
This mandatory TLV is sent by default once you enable LLDP on the port. It is not configurable. The ExtremeWare XOS software uses the systems MAC address to uniquely identify the device. EDP also uses this to identify the device.

Port ID TLV
This mandatory TLV is sent by default once you enable LLDP on the port; you cannot configure this TLV. The port ID TLV is used to uniquely identify the port within the device. The software uses the ifName object for this TLV, so it is the port number on stand-alone switches and the combination of slot and port number on modular switches.

TTL TLV
The TTL TLV is mandatory, sent by default once LLDP is enabled, and nonconfigurable. This TLV indicates how long the record should be maintained in the LLDP database. The default value is 120 seconds (or 2 minutes). A value of 0 in the TTL TLV means the client is shutting down and that record should be deleted from the database. When you disable an LLDP port, the triggered update LLDPU from that port contains a TTL TLV of zero. The TTL TLV is mandatory and is sent by default once LLDP is enabled. Although, technically, you do not configure the TTL TLV, you can configure the transmit hold value, which is used to calculate the TTL TLV. (See Configuring LLDP Timers on page 157 for more information on transmit hold value and TTL.)

End-of-LLDPDU TLV
The end-of-LLDPDU TLV marks the end of the data. The system automatically adds this TLV to the LLDPDU once you enable LLDP.

Optional TLVs
All the optional TLVs are configurable using the CLI and/or SNMP.

152

ExtremeWare XOS 11.3 Concepts Guide

Supported TLVs

NOTE
The system description TLV is automatically enabled once you enable LLDP and is always sent as part of the LLDPDU. Although this TLV is not mandatory according to the standard, the ExtremeWare XOS software includes this TLV in all LLDPDUs by default; you can configure the system not to advertise this TLV.

This section discusses the following optional TLVs:


Port Description TLV on page 153 System Name TLV on page 153 System Description TLV on page 153 System Capabilities TLV on page 154 Management Address TLV on page 154 VLAN Name TLV on page 154 Port VLAN ID TLV on page 154 Port and Protocol VLAN ID TLV on page 154 MAC/PHY Configuration/Status TLV on page 155 Power via MDI TLV on page 155 Link Aggregation TLV on page 155 Maximum Frame Size TLV on page 155

Port Description TLV


You configure this TLV to be advertised or not advertised. The port description TLV contains the ifDescr object, which is the ASCII string you entered using the configure ports display-string command. If you have not configured this parameter, the TLV carries an empty string.

System Name TLV


You configure this TLV to be advertised or not advertised. The system name TLV contains the devices configured system name, if previously configured using SNMP. This is the sysName as defined in RFC 3418, which you define using the configure snmp sysname command.

System Description TLV


This is the only TLV that is enabled by default but not mandatory according to the standard. The ExtremeWare XOS implementation sends this TLV, by default, whenever you enable LLDP on a port. You can disable sending this TLV once you enable LLDP; but, by default, the system sends this TLV. When enabled, the system sends the image information (from the show version command) in the system description TLV:
ExtremeWare XOS version 11.2.0.12 v1120b12 by release-manager on Fri Mar 18 16:01:08 PST 2005

ExtremeWare XOS 11.3 Concepts Guide

153

Link Layer Discovery Protocol

System Capabilities TLV


You configure this TLV to be advertised or not advertised. The system capabilities TLV indicates the devices capabilities and which of these are enabled. The ExtremeWare XOS software advertises bridge and router capabilities. When configured to advertise the system capabilities, Extreme Networks devices advertise bridging capabilities. Once at least one VLAN on the device has IP forwarding enabled, the system automatically advertises router capabilities.

Management Address TLV


You configure this TLV to be advertised or not advertised. The management address TLV supplies the management entity for the device. ExtremeWare XOS advertises only one management TLV. That management TLV is the IP address of the management VLAN. If the management VLAN does not have an assigned IP address, the management address TLV advertises the systems MAC address. LLDP does not recognize IPv6 addresses in this field.

VLAN Name TLV


You configure this TLV to be advertised or not advertised. This TLV can be repeated several times within one LLDPDU. The ExtremeWare XOS software allows you to advertise VLAN name information to neighboring devices. This TLV associates a VLAN name to the IEEE 802.1Q tag assigned to that VLAN. You can enable this TLV for tagged and untagged VLANs. When you enable this TLV for tagged VLANs, the TLV advertises the IEEE 802.1Q tag for that VLAN. (For untagged VLANs, the internal tag is advertised.) You can specify exactly which VLANs to advertise. By default, once you configure this TLV, the system sends all VLAN names on the port. However, each VLAN name requires 32 bits and the LLDPDU cannot exceed 1500 bytes, so you should configure the port to advertise only the specified VLANs.

Port VLAN ID TLV


You configure this TLV to be advertised or not advertised. The port VLAN ID advertises the untagged VLAN on that port. Thus, only one port VLAN ID TLV can exist in the LLDPDU. If you configure this TLV and there is no untagged VLAN on the particular port, this TLV is not included in the LLDPDU.

Port and Protocol VLAN ID TLV


You configure this TLV to be advertised or not advertised. This TLV can be repeated several times within one LLDPDU. When configured, this TLV allows the port to advertise VLANs and whether the port supports protocolbased VLANs or not. If no protocol-based VLANs are configured on the port, the TLV still advertises the ports capability and sets the VLAN ID value to zero.

154

ExtremeWare XOS 11.3 Concepts Guide

Supported TLVs As Extreme Networks devices are always capable of supporting protocol-based VLANs, once you configure this TLV, the system always advertises support for this type of VLAN. By default, once you configure this TLV, the system sends information for all VLANs on the port. However, as VLAN TLV requires space and the LLDPDU cannot exceed 1500 bytes, you should configure the port to advertise only specified VLANs.

MAC/PHY Configuration/Status TLV


You configure this TLV to be advertised or not advertised. Once configured, this TLV advertises autonegotiation and physical layer capabilities of the port. The system adds information about the speed rate, duplex setting, bit rate, physical interface, and autonegotiation support and status.

Power via MDI TLV


You configure this TLV to be advertised or not advertised. When enabled, this TLV is included in the LLDPDU only for those ports that support supplying power over Ethernet (PoE). This TLV allows network management to advertise and discover the power-via-MDI capabilities of the sending 802.3 LAN station. The device type field contains a binary value that represents whether an LLDP-MED device transmitting the LLDPDU is a power sourcing entity (PSE) or power device (PD), as listed in Table 19.

Table 19: Power management TLV device information


Value 0 1 2-3 Power source PSE device PD device Reserved

Additional PoE information is advertised as well, including the power status, power class, and pin pairs used to supply power.

Link Aggregation TLV


You configure this TLV to be advertised or not advertised. When enabled, this TLV advertises information on the ports load-sharing (link aggregation) capabilities and status.

Maximum Frame Size TLV


You configure this TLV to be advertised or not advertised. This TLV allows the port to advertise its maximum supported frame size to its neighbors. When jumbo frames are not enabled on the specified port, the TLV reports a value of 1518 once you configure it to advertise. If jumbo frames are enabled, the TLV inserts the configured value for the jumbo frames.

ExtremeWare XOS 11.3 Concepts Guide

155

Link Layer Discovery Protocol

Configuring LLDP
You configure LLDP per port. To configure LLDP, take the following steps: 1 Enable LLDP on the desired port(s). 2 If desired, configure the system not to advertise the system description TLV. 3 If you want to change any default values, configure the following values: a Reinitialize period b Transmit interval c Transmit delay d Transmit hold 4 Enable the SNMP traps and configure the notification interval. 5 Configure any optional TLV advertisements that you want included in the LLDPDU. This section discusses how to configure LLDP using the CLI. Refer to ExtremeWare XOS Command Reference Guide for complete information on configuring LLDP You can also reference the IEEE 892,1ab standard.

Enabling and Disabling LLDP


LLDP is disabled on all ports by default. When you enable LLDP on the ports, you select whether the ports will only transmit LLDP messages, only receive the messages, or both transmit and receive LLDP messages. To enable LLDP, use the following command:
enable lldp ports [all | <port_list>] {receive-only | transmit-only}

Once you enable LLDP, the following TLVs are automatically added to the LLDPDU:

Chassis ID Port ID TTL System description End of LLDPDU

All of these, except the system description, are mandated by the 802.1ab standard. Similarly, none of these, except the system description, can be configured to advertise or not to advertise. To disable LLDP, use the following command:
disable lldp ports [all | <port_list>] {receive-only | transmit-only}

Configuring the System Description TLV Advertisement


If you have not configured the system description using SNMP sysName prior to enabling LLDP, the system sends the following information in the system description TLV:
ExtremeWare XOS version 11.2.0.12 v1120b12 by release-manager on Fri Mar 18 16:01:08 PST 2005

156

ExtremeWare XOS 11.3 Concepts Guide

Configuring LLDP To disable the default advertisement of the system description, issue the following command:
configure lldp ports [all | <port_list>] no-advertise system-description

Configuring LLDP Timers


Once you enable LLDP, the timer values assume the default values. However, if you want to change any of these default values, use the CLI to configure the relevant timer. NOTE
The LLDP timers apply to the entire device and are not configurable by port.

When LLDP is disabled or if the link goes down, LLDP is reinitialized. The reinitialize delay is the number of seconds the port waits to restart LLDP state machine; the default is 2 seconds. To change the default reinitialize delay period, use the following command:
configure lldp reinitialize-delay <seconds>

LLDP messages are transmitted at a set interval; this interval has a default value of every 30 seconds. To change this default value, issue the following command:
configure lldp transmit-interval <seconds>

The time between triggered update LLDP messages is referred to as the transmit delay, and the default value is 2 seconds. You can change the default transmit delay value to a specified number of seconds or to be automatically calculated by multiplying the transmit interval by 0.25. To change the value for the transmit delay, issue the following command:
configure lldp transmit-delay [ auto | <seconds>]

Each LLDP message contains a TTL value. The receiving LLDP agent discards all LLDP messages that surpass the TTL value; the default value is 120 seconds. The TTL is calculated by multiplying the transmit interval value and the transmit hold value; the default transmit hold value is 4. To change the default transmit hold value, issue the following command:
configure lldp transmit-hold <hold>

Configuring SNMP for LLDP


You can send SNMP traps regarding LLDP; the software supports the LLDP MIB. By default, SNMP LLDP traps are disabled on all ports; to enable LLDP SNMP traps, issue the following command:
enable snmp traps lldp {ports [all | <port_list>]}

The traps are only sent for those ports that are both enabled for LLDP and have LLDP traps enabled. To disable the LLDP SNMP traps, issue the following command:
disable snmp traps lldp {ports [all | <port_list>]}

ExtremeWare XOS 11.3 Concepts Guide

157

Link Layer Discovery Protocol The default value for the interval between SNMP LLDP trap notifications is 5 seconds. You change this interval for the entire switch for LLDP traps using the following command:
configure lldp snmp-notification-interval <seconds>

Configuring Optional TLV Advertisements


By default, all optional TLVs are not added to the LLDPDU, or not advertised. You can add optional TLVs to the LLDPDU but be aware that the total LLDPDU cannot exceed 1500 bytes, including the mandatory TLVs. Any optional added TLVs that exceed the 1500-byte limit are dropped. You can see if you have dropped TLVs from your LLDPDU by referring to the EMS log or by issuing the show lldp statistics command.

NOTE
Extreme Networks recommends that you advertise only one or two VLANS on specified ports to avoid dropping TLVs from the LLDPDU.

You configure LLDP ports to advertise any of the following optional TLVs:

Port description TLV System name TLV System capabilities TLV Management address TLV VLAN name TLV (repeatable TLVs) Port VLAN ID TLV Port and protocol VLAN ID TLV (repeatable TLVs) MAC/PHY configuration/status TLV Power via MDI TLV Link aggregation TLV Maximum frame size TLV

Refer to Optional TLVs on page 152 for complete information on each optional TLV. To advertise the optional port description information, issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] port-description

To advertise the system name, issue the following command:


configure lldp ports [all | <port_list>] [advertise | no-advertise] system-name

To advertise the system capabilities, issue the following command:


configure lldp ports [all | <port_list>] [advertise | no-advertise] systemcapabilities

158

ExtremeWare XOS 11.3 Concepts Guide

Configuring LLDP To advertise the IP address of the management VLAN (or the system MAC address if IP is not configured), issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] managementaddress

You can advertise more than one VLAN name per LLDP-enabled port. To do so, add one optional VLAN name TLV for each VLAN you want to advertise. If you do not specify VLAN names, the system sends an advertisement for all VLANs on the port. To advertise VLAN names, issue the following command:
configure lldp ports [all | <port_list>] [advertise | dont-advertise] vendorspecific dot1 vlan-name {vlan [all | <vlan_name>]}

NOTE
The total LLPDU size is 1500 bytes; any TLVs after that limit are dropped.

You can advertise the untagged, port-based VLAN for the LLDP-enabled port using the port VLAN ID TLV. Configure the port VLAN ID TLV by issuing the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot1 port-vlan-ID

You can advertise more than one protocol-based VLAN per LLDP-enabled port. To do so, add one optional port and protocol VLAN ID TLV for each VLAN you want to advertise. To advertise these VLANs, issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot1 port-protocol-vlan-ID {vlan [all | <vlan_name>]}

NOTE
The total LLPDU size is 1500 bytes; any TLVs after that limit are dropped.

You can advertise the speed capabilities, autonegotiation support and status and physical interface of the LLDP-enabled port using the MAC/PHY configuration/status TLV. To advertise this information, issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot3 mac-phy

Configure the power via MDI TLV to advertise the PoE capabilities of the LLDP-enabled port. Issue the following command to advertise the PoE capabilities and status:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot3 power-via-mdi

You advertise the load-sharing capabilities and status of the LLDP-enabled port by configuring the link aggregation TLV. To advertise load-sharing capabilities, issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot3 link-aggregation

ExtremeWare XOS 11.3 Concepts Guide

159

Link Layer Discovery Protocol You advertise the maximum frame size available on the LLDP-enabled port using the maximum frame size TLV. To advertise the maximum frame size, issue the following command:
configure lldp ports [all | <port_list>] [advertise | no-advertise] vendor-specific dot3 max-frame-size

Unconfiguring LLDP
To unconfigure LLD, issue the following command:
unconfigure lldp

This command only returns the LLDP timers to default values; LLDP remains enabled, and all the configured TLVs are still advertised. To leave LLDP enabled, but reset the advertised TLVs to the five default TLVs, issue the following command, and specify the affected ports:
unconfigure lldp port [all | <port_list>]

Displaying LLDP Settings


The system displays information on the LLDP status and statistical counters of the ports, as well as about the LLDP advertisements received and stored by the system. You can display information on the LLDP port configuration and on the LLDP neighbors detected on the port. NOTE
Refer to ExtremeWare XOS Command Reference Guide for complete information on displaying LLDP settings.

Displaying LLDP Port Configuration Information


Use the show lldp command to display LLDP port configuration information. To display detailed LLDP information, add the detailed option. The following is sample output of the show lldp command:
# show lldp LLDP LLDP LLDP LLDP LLDP transmit interval transmit hold multiplier transmit delay SNMP notification interval reinitialize delay : : : : : 30 seconds 4 (used TTL = 120 seconds) 2 seconds 5 seconds 2 seconds

160

ExtremeWare XOS 11.3 Concepts Guide

Displaying LLDP Settings


LLDP Port Configuration: Port Rx Tx SNMP Optional enabled transmit TLVs Mode Mode Notification LLDP 802.1 802.3 ============================================================================ 1:1 Enabled Enabled Disabled PNDCM PpNM-LF 2:2 Enabled Enabled Disabled --D-- ------============================================================================= LLDP Flags : (P) Port Description, (N) System Name, (D) System Description (C) System Capabilities, (M) Mgmt Address 802.1 Flags: (P) Port VLAN ID, (p) Port & Protocol VLAN ID, (N) VLAN Name 802.3 Flags: (M) MAC/PHY Configuration/Status, (P) Power via MDI (L) Link Aggregation, (F) Frame Size

The following sample output is from the show lldp port 1 detailed command:
# show lldp port 1 detailed LLDP LLDP LLDP LLDP LLDP transmit interval transmit hold multiplier transmit delay SNMP notification interval reinitialize delay : : : : : 30 seconds 4 (used TTL = 120 seconds) 2 seconds 5 seconds 2 seconds

LLDP Port Configuration: Port Rx Tx SNMP Optional enabled transmit TLVs Mode Mode Notification LLDP 802.1 802.3 ============================================================================ 1 Enabled Enabled Disabled -ND-- --N---VLAN: Default ----- ------VLAN: voice ----- --N---============================================================================= LLDP Flags : (P) Port Description, (N) System Name, (D) System Description (C) System Capabilities, (M) Mgmt Address 802.1 Flags: (P) Port VLAN ID, (p) Port & Protocol VLAN ID, (N) VLAN Name 802.3 Flags: (M) MAC/PHY Configuration/Status, (P) Power via MDI (L) Link Aggregation, (F) Frame Size

Use the show lldp statistics command to display the statistical counters related to the LLDP port. The following is sample output from the show lldp statistics command:
# show lldp statistics Last table change time Number of Table Inserts Number of Table Deletes Number of Table Drops Number of Table Age Outs Port : : : : : Fri Dec 17 10:42:33 2004 3 0 0 0

Tx Tx Length Rx Rx Rx TLVs TLVs Total Exceeded Total Discarded Errors Discarded Unrecogn. =================================================================================== 1:1 189 0 5654 0 0 0 0 2:2 188 0 565 0 0 0 0

ExtremeWare XOS 11.3 Concepts Guide

161

Link Layer Discovery Protocol

NOTE
The Tx Length Exceeded column shows the number of LLDPDUs sent from the port that dropped configured optional TLVs to meet the 1500-byte limit for the LLDPDU.

Displaying LLDP Information Detected from Neighboring Ports


To display information from LLDP neighbors detected on the port, use the show lldp neighbors command. The following is sample output from the show lldp neighbors command:
# show lldp neighbors Port Neighbor Chassis ID Neighbor Port ID TTL Age ============================================================================= 4:1 00:04:96:10:51:81 1:69 120 29 4:1 00:30:48:42:F3:12 1:1 120 1 4:2 00:04:96:10:51:80 1:1 120 60 ============================================================================= NOTE: The Chassis ID and/or Port ID might be truncated to fit the screen.

For detailed LLDP neighbor information for all switch ports, use the show lldp neighbors detailed command. The following is sample output from the this command:
# show lldp all neighbors detailed ----------------------------------------------------------------------------LLDP Port 4:1 detected 2 neighbors Neighbor: 00:04:96:10:51:81/1:2, age 29 seconds - Chassid ID Type: MAC Address (4) Chassis ID : "00:04:96:10:51:81" - Port ID Type: ifName (5) Port ID : "1:2" - Time to Live: 120 seconds Neighbor: 00:30:48:42:F3:12/1:1, age 1 seconds - Chassis ID type: MAC address (4) Chassis ID : 00:30:48:42:F3:12 - Port ID type: ifName (5) Port ID : "1:1" - Time To Live: 120 seconds - Port Description: Port-2-Internet - System Name: CoreSwitch01 - System Description: "ExtremeWare X0S version 11.2.0.0 branch-shasta7_v\ 1111b7 by eelco on Tue Dec 14 09:51:30 CET 2004" - System Capabilities : "Bridge, Router" Enabled Capabilities: "Bridge" ----------------------------------------------------------------------------LLDP Port 4:2 detected 1 neighbor Neighbor: 00:04:96:10:51:80/1:2, age 60 seconds - Chassid ID Type: MAC Address (4) Chassis ID : "00:04:96:10:51:80" - Port ID Type: ifName (5) Port ID : "1:1" - Time to Live: 120 seconds

162

ExtremeWare XOS 11.3 Concepts Guide

Power Over Ethernet

Power over Ethernet (PoE) is an effective method of supplying 48 VDC power to certain types of powered devices (PDs) through Category 5 or Category 3 twisted pair Ethernet cables. PDs include wireless access points, IP telephones, laptop computers, web cameras, and other devices. With PoE, a single Ethernet cable supplies power and the data connection, reducing costs associated with separate power cabling and supply. Beginning with ExtremeWare XOS version 11.3, the system supports hitless failover for PoE in a system with two Master Switch Modules (MSMs). Hitless failover means that if the primary MSM fails over to the backup MSM, all port currently powered will maintain power after the failover and all the power configurations remain active.

NOTE
The BlackDiamond 8800 family of switches was formerly known as Aspen.

This chapter covers the following topics:


Summary of PoE Features on page 163 Power Checking for PoE Module on page 164 Power Delivery on page 164 LEDs on page 168 Configuring PoE on page 169 Displaying PoE Settings and Statistics on page 173

Summary of PoE Features


The G48P module for the BlackDiamond 8800 family of switches (formerly known as Aspen) supports the following PoE features:

Configuration and control of the power distribution for PoE at the system, slot, and port levels Real-time discovery and classification of 802.3af-compliant PDs and many legacy devices Monitor and control of port PoE fault conditions including exceeding configured class limits and power limits and short-circuit detection Support for configuring and monitoring PoE status at the system, slot, and port levels Management of an over-subscribed power budget Port LED control for indicating the link state Support for hitless failover in a chassis with two MSMs

For detailed information on using the PoE commands to configure, manage, and display PoE settings, refer to the ExtremeWare XOS Command Reference Guide.

ExtremeWare XOS 11.3 Concepts Guide

163

Power Over Ethernet

Power Checking for PoE Module


PoE modules require more power than other I/O modules. When a chassis containing a PoE module is booted or a new PoE module is inserted, the power drain is calculated. Before the PoE module is powered up, the chassis calculates the power budget and powers up the PoE module only if there is enough power. The chassis powers up as many I/O modules as possible with lower-numbered slots having priority. NOTE
If your chassis has an inline power module and there is not enough power to supply the configured inline power for the slot, that slot will not power on; the slot will not function in data-only mode without enough power for inline power.

If a PoE module is inserted into a chassis, the chassis calculates the power budget and only powers up the PoE module if there is enough power. Installed modules are not affected. However, if you reboot the chassis, power checking proceeds as described in the previous paragraph. If there is now enough power, I/O modules that were not powered up previously are powered up. If you lose power or the overall available power decreases, the system removes power to the I/O modules beginning with the highest numbered slots until enough power is available. Inline power reserved for a slot that is not used cannot be used by other PoE slots (inline power is not shared among PoE modules). Before you install your PoE module, consult your sales team to determine the required power budget.

Power Delivery
This section discusses how the system provides power to the PDs.

Enabling PoE to the Switch


You enable or disable inline power to the entire switch, or per slot or per port. Then you must reserve power for each PoE Slot (refer to Power Reserve Budget Per Slot). By default, 50 watts of inline power is provided to each slot. To enable inline power to the switch, slot, or port, use the following commands:
enable inline-power

To disable inline power to the switch, use the following command:


disable inline-power

Disabling inline power removes power immediately to all connected PDs. The default value is enabled.

Power Reserve Budget Per Slot


The power budget is provided on a per slot basis, not switchwide. You reserve power for each slot, or PoE module. Power reserved for a specific PoE module cannot be used by any other slot regardless of

164

ExtremeWare XOS 11.3 Concepts Guide

Power Delivery how much power is actually consumed on the specified slot. The default power budget reserved for each PoE module is 50 W. The minimum power you can assign to a slot is 37 W, or 0 W if the slot is disabled. The maximum possible for each slot is 768 W. To reduce the chances of ports fluctuating between powered and non-powered states, newly inserted PDs are not powered when the actual delivered power for the module is within approximately 19 W of the configured inline power budget for that slot. However, actual aggregate power can be delivered up to the configured inline power budget for the slot (for example, when delivered power from ports increases or when the configured inline power budget for the slot is reduced).

NOTE
Extreme Networks recommends that you fully populate a single PoE module with PDs until the power usage is just below the usage threshold, instead of spacing PDs evenly across PoE modules.

Use the following command to reserve the power budget for the PoE module slot:
configure inline-power budget <num_watts> slot <slot>

If you disable a slot with a PoE module, the reserved power budget remains with that slot until you unconfigure or reconfigure the power budget. Also, you can reconfigure the reserved power budget for a PoE module without disabling the slot first; you can reconfigure dynamically. These settings are preserved across reboots and other power-cycling conditions. The total of all reserved slot power budgets cannot be larger than the total available power to the switch. If the base module power requirements plus the reserved PoE power for all modules exceeds the unallocated power in the system, the lowest numbered slots have priority in getting power and one or more modules in higher-numbered slots will be powered down.

NOTE
PoE modules are not powered-up at all, even in data-only mode, if the reserved PoE power cannot be allocated to that slot.

To reset the reserved power budget for a slot to the default value of 50 W, use the following command:
unconfigure inline-power budget slot <slot>

PD Disconnect Precedence
After a PD is discovered and powered, the actual power drain is continuously measured, If the usage for power by PDs is within 19 W of the reserved power budget for the PoE module, the system begins denying power to PDs. To supply power to all PDs, you can reconfigure the reserved power budget for the slot, so that enough power is available to power all PDs. You reconfigure the reserved power budget dynamically; you do not have to disable the slot to reconfigure the power budget. You configure the switch to handle a request for power that exceeds the power budget situation in one of two ways, called the disconnect precedence:

Disconnect PDs according to the configured PoE port priority for each device

ExtremeWare XOS 11.3 Concepts Guide

165

Power Over Ethernet

Deny power to the next PD requesting power, regardless of that ports PoE priority

This is a switchwide configuration that applies to each slot; you cannot configure this disconnect precedence per slot. The default value is deny-port. So, if you do not change the default value and the slots power is exceeded, the next PD requesting power is not connected (even if that port has a higher configured PoE port priority than those ports already receiving power). When you configure the deny-port value, the switch disregards the configured PoE port priority and port numbering. When the switch is configured for lowest-priority mode, PDs are denied power based on the ports configured PoE priority. If the next PD requesting power is of a higher configured PoE priority than an already powered port, the lower-priority port is disconnected and the higher-priority port is powered. To configure the disconnect precedence for the switch, use the following command:
configure inline-power disconnect-precedence [deny-port | lowest-priority]

To reset the disconnect precedence value to the default value of deny port to the switch, use the following command:
unconfigure inline-power disconnect-precedence

PoE Port Priority


You can configure the PoE priority for each port as low, high, or critical; the default value is low. If you configure the disconnect precedence of the switch as lowest priority, the switch disconnects those PDs with lower PoE port priorities when the reserved slot power budget is exceeded; the system continues supplying power to PDs with higher PoE port priorities. To set the PoE port priority, use the following command:
configure inline-power priority [critical | high | low] ports <port_list>

To reset the PoE priority of the ports to the default value of low, use the following command:
unconfigure inline-power priority ports [all | <port_list>]

If several PDs have the same configured PoE port priority, the priority is determined by the port number. The highest port number has the lowest PoE priority. The switch withdraws power (or disconnects) those ports with the highest port number (s). That is, the highest port number is the lowest PoE priority.

Port Disconnect or Fault


When a port is disconnected, the power is removed from that port and can be used only by ports on the same slot. The power from the disconnected port is not redistributed to any other slot. When a port enters a fault state because of a class violation or if you set the operator limit lower than the amount requested by the PD, the system removes power from that port. The power removed is, again, available only to other ports on the same slot; it cannot be redistributed to other slots. The port stays in the fault state until you disable that port, or disconnect the attached PD, or reconfigure the operator limit to be high enough to satisfy the PD requirements.

166

ExtremeWare XOS 11.3 Concepts Guide

Power Delivery To display the status of PoE ports, including disconnected or faulted ports, use the following command:
show inline-power info ports

When a port is disconnected or otherwise moves into a fault state, SNMP generates an event (once you configure SNMP and a log message is created).

Port Power Reset


You can set ports to experience a power-down, discover, power-up cycle without returning the power to the slots reserved power budget. This function allows you to reset PDs without losing their claim to the reserved power budget. The following command power cycles the specified ports:
reset inline-power ports <port_list>

Ports are immediately depowered and repowered, maintaining current power allocations.

PoE Usage Threshold


The system generates an SNMP event when any slot has consumed a specified percentage of that slots reserved power budget. The default value is 70%; you can configure this threshold to generate events from 1% to 99% consumption of the reserved power budget. This threshold percentage is set to be the same for each PoE slot; you cannot configure it differently for each PoE module. You can also configure the system to log an Event Management System (EMS) message when the usage threshold is crossed (refer to Chapter 8 for more information on EMS). Although the threshold percentage of measured to budgeted power applies to all PoE modules, the threshold measurement applies only to the percentage per slot of measured power to budgeted power use; it does not apply to the amount of power used switchwide. To configure the threshold percentage of budgeted power used on a slot that causes the system to generate an SNMP event and EMS message, use the following command:
configure inline-power usage-threshold <threshold>

To reset the threshold that causes the system to generate an SNMP event and EMS message per slot to 70% for measured power compared to budgeted power, use the following command:
unconfigure inline-power usage-threshold

Legacy Devices
ExtremeWare XOS software allows the use of non-standard PDs with the switch. These are PDs that do not comply with the IEEE 802.3af standard. The system detects non-standard PDs using a capacitance measurement. You must enable the switch to detect legacy devices; the default value is disabled. You configure the detection of legacy PoE devices per slot.

ExtremeWare XOS 11.3 Concepts Guide

167

Power Over Ethernet Detecting a PD through capacitance is used only if the following two conditions are both met:

Legacy PD detection is enabled. The system unsuccessfully attempted to discover the PD using the standard resistance measurement method.

To enable the switch to use legacy PDs, use the following command:
enable inline-power legacy slot <slot>

To disable the non-standard power detection method that allows the switch to use legacy PDs, use the following command:
disable inline-power legacy slot <slot>

PoE Operator Limits


You set the power limit that a PD can draw on the specified ports. The range is 3000 to 16800 mW, and the default value is 15400 mW. You set the operator limit on specified ports, which limits how much power a PD can draw from that port by using the following command:
configure inline-power operator-limit <milliwatts> ports [all |<port_list>]

If the measured power for a specified port exceeds the ports operator limit, the power is withdrawn from that port and the port moves into a fault state. To reset the power limit allowed for PDs to the default value of 15.4 W per port, use the following command:
unconfigure inline-power operator-limit ports [all |<port_list>]

If you attempt to set an operator-limit outside the accepted range, the system returns an error message.

LEDs
Individual port LEDs on the PoE module also indicate the inline power status of each port (Table 20).

Table 20: PoE port LEDs


Port Power Device powered Power fault or insufficient power Nonpowered device Port Disabled Slow blinking amber Blinking amber/green Slow blinking green Port Enabled: Link Down Slow blinking amber Blinking amber/green Off Port Enabled: Link Up Solid amber Blinking amber/green Solid green Activity Blinking amber Blinking amber/ green Blinking green

168

ExtremeWare XOS 11.3 Concepts Guide

Configuring PoE

Configuring PoE
PoE on the G48P module supports a full set of configuration and monitoring commands that allow you configure, manage, and display PoE settings at the system, slot, and port level. Refer to the ExtremeWare XOS Command Reference Guide for complete information on using the CLI commands. To enable inline power, or PoE, you must have a powered chassis and module.

NOTE
If your chassis has an inline power module and there is not enough power to supply a slot, that slot will not power on; the slot will not function in data-only mode without enough power for inline power.

To configure inline power, or PoE, you must accomplish the following tasks:

Enable inline power to the system, slot, and/or port. Reserve power to the PoE slot, using a power budget. Configure the disconnect precedence for the PDs in the case of excessive power demands. Configure the threshold for initiating system alarms on power usage.

Additionally, you can configure the switch to use legacy PDs, apply specified PoE limits to ports, apply labels to PoE ports, and configure the switch to allow you to reset a PD without losing its power allocation.

Enabling Inline Power


You enable inline power to the switch, slot, or port using the following commands:
enable inline-power enable inline-power slot <slot> enable inline-power ports [all | <port_list>]

NOTE
If your chassis has an inline power module and there is not enough power to supply a slot, that slot will not power on; the slot will not function in data-only mode without enough power for inline power.

To disable inline power to the switch, slot, or port, use the following commands:
disable inline-power disable inline-power slot <slot> disable inline-power ports [all | <port_list>]

Disabling the inline power to a PD immediately removes power from the PD. To display the configuration for inline power, use the following command:
show inline-power

ExtremeWare XOS 11.3 Concepts Guide

169

Power Over Ethernet

Reserving Power for a Slot


You reserve power for a given slot. The power reserved for a given slot cannot be used by any other PoE slots, even if the assigned power is not entirely used. To reallocate power among the slots, you must reconfigure each slot for the power budget you want; the power is not dynamically reallocated among PoE modules. You do not have to disable the PoE modules to reconfigure the power budgets. To set the budgeted power reserved for all PDs on a given slot, use the following command:
configure inline-power budget <num_watts> slot <slot>

The default power budget is 50 W per slot, and the maximum is 768 W. The minimum reserved power budget you can configure is 37 W for an enabled slot. If inline power on the slot is disabled, you can configure a power budget of 0.

NOTE
Extreme Networks recommends that you fully populate a single PoE module with PDs until the power usage is just below the usage threshold, instead of spacing PDs evenly across PoE modules.

To reset the power budget for a PoE module to the default value of 50 W, use the following command:
unconfigure inline-power budget slot <slot>

To display the reserved power budget for the PoE modules, use the following command:
show inline-power slot <slot>

Setting the Disconnect Precedence


NOTE
The switch generates an SNMP event if a PD goes offline, and the ports state moves from Power to Searching. You must configure SNMP to generate this event.

When the actual power used by the PDs on a slot exceeds the power budgeted for that slot, the switch refuses power to PDs. There are two methods used by the switch to refuse power to PDs, and whichever method is in place applies to all PoE slots in the switch. This is called the disconnect precedence method, and you configure one method for the entire switch. The available disconnect precedence methods are:

Deny port Lowest priority

The default value is deny port. Using this method, the switch simply denies power to the next PD requesting power from the slot, regardless of that ports PoE priority or port number. Using the lowest priority method of disconnect precedence, the switch disconnects the PDs connected to ports configured with lower PoE priorities. (Refer to Configuring the PoE Port Priority for information on port priorities.)

170

ExtremeWare XOS 11.3 Concepts Guide

Configuring PoE When several ports have the same PoE priority, the lower port numbers have higher PoE priorities. That is, the switch withdraws power (or disconnects) those ports with the highest port number(s). The system keeps dropping ports, using the algorithm you selected with the disconnect ports command, until the measured inline power for the slot is lower than the reserved inline power. Use the following command to configure the disconnect precedence for the switch:
configure inline-power disconnect-precedence [deny-port | lowest-priority]

To return the disconnect precedence to the default value of deny port, use the following command:
unconfigure inline-power disconnect-precedence

To display the currently configured disconnect precedence, use the following command:
show inline-power

To reduce the chances of ports fluctuating between powered and non-powered states, newly inserted PDs are not powered when the actual delivered power for the module is within approximately 19 W of the configured inline power budget for that slot. However, actual aggregate power can be delivered up to the configured inline power budget for the slot (for example, when delivered power from ports increases or when the configured inline power budget for the slot is reduced).

Configuring the PoE Port Priority


You can configure the PoE port priority to be low, high, or critical. The default value is low. If you configure the disconnect precedence as lowest priority and the PDs request power in excess of the slots reserved power budget, the system allocates power to those ports with the highest priorities first. If several ports have the same PoE priority, the lower port numbers have higher PoE priorities. That is, the switch withdraws power (or disconnects) those ports with the highest port number(s). To configure PoE port priority, use the following command:
configure inline-power priority [critical | high | low] ports <port_list>

To reset the port priority to the default value of low, use the following command:
unconfigure inline-power priority ports [all | <port_list>]

To display the PoE port priorities, use the following command:


show inline-power configuration ports <port_list>

Configuring the Usage Threshold


The system generates an SNMP event once a preset percentage of the reserved power for any slot is actually used by a connected PD. This preset percentage is called the usage threshold and is the percentage of the measured power to the budgeted power for each slot.

ExtremeWare XOS 11.3 Concepts Guide

171

Power Over Ethernet Although the percentage of used to budgeted power is measured by each PoE module, you set the threshold for sending the event for the entire switch. That is, once any PoE module passes the configured threshold, the system sends an event. The default value for this usage threshold is 70%. You can configure the usage threshold to be any integer between 1% and 99%. To configure the usage threshold, issue the following command:
configure inline-power usage-threshold <threshold>

To reset the usage threshold to 70%, use the following command:


unconfigure inline-power usage-threshold

To display the currently configured usage threshold, use the following command:
show inline-power

Configuring the Switch to Detect Legacy PDs


The PoE module can detect non-standard, legacy PDs, which do not conform to the IEEE 802.3af standard, using a capacitance measurement. However, you must specifically enable the switch to detect these non-standard PDs; the default value for this detection method is disabled. This configuration applies to the entire switch; you cannot configure the detection method per slot. The switch detects PDs through capacitance only if both of the following conditions are met:

The legacy detection method is enabled. The switch unsuccessfully attempted to discover the PD using the standard resistance measurement method.

To enable the switch to detect legacy, non-standard PDs, use the following command:
enable inline-power legacy slot <slot>

To reset the switch to the default value, which does not detect legacy PDs, use the following command:
disable inline-power legacy slot <slot>

To display the status of legacy detection, use the following command:


show inline-power

Configuring the Operator Limit


You configure the maximum amount of power that the specified port can deliver to the connected PD, in milliwatts. The default value is 15400 mW, and the range is 3000 to 16800 mW. If the operator limit for a specified port is less than the power drawn by the legacy PD, the legacy PD is denied power.

172

ExtremeWare XOS 11.3 Concepts Guide

Displaying PoE Settings and Statistics To configure the operator limit, use the following command:
configure inline-power operator-limit <milliwatts> ports [all |<port_list>]

To reset the operator limit to the default value of 15.4 W, use the following command:
unconfigure inline-power operator-limit ports [all |<port_list>]

To display the current operator limit on each port, use the following command:
show inline-power configuration ports <port_list>

Configuring PoE Port Labels


You can assign labels to a single or group of PoE ports using a string of up to 15 characters. Use the following command to assign a label to PoE ports:
configure inline-power label <string> ports <port_list>

To rename a port or to return it to a blank label, reissue the command. To display the PoE port labels, use the following command:
show inline-power configuration ports <port_list>

Power Cycling Connected PDs


You can power cycle a connected PD without losing the power allocated to its port. Use the following command:
reset inline-power ports <port_list>

Displaying PoE Settings and Statistics


You can display the PoE status, configuration, and statistics for the system, slot, and port levels.

Clearing Statistics
You can clear the PoE statistics for specified ports or for all ports. To clear the statistics and reset the counters to 0, use the following command:
clear inline-power stats ports [all | <port_list>]

Displaying System Power Information


You can display the status of the inline power for the system and, for additional information, display the power budget of the switch.

ExtremeWare XOS 11.3 Concepts Guide

173

Power Over Ethernet

Displaying System PoE Status


To display the PoE status for the switch, use the following command:
show inline-power

The command provides status for the following areas:


Configured inline power statusThe status of the inline power for the switch: enabled or disabled. System power surplusThe surplus amount of power on the system, in watts, available for budgeting. Redundant power surplusThe amount of power on the system, in watts, available for budgeting if one power supply is lost. System power usage thresholdThe configured power usage threshold for each slot, shown as a percentage of budgeted power. Once this threshold has been passed on any slot, the system sends an SNMP event and logs a message. Disconnect precedenceThe method of denying power to PDs if the budgeted power on any slot is exceeded. Legacy modeThe status of the legacy mode, which allows detection of non-standard PDs.

The output indicates the following inline power status information for each slot:

Inline power statusThe status of inline power. The status conditions are:

Enabled Disabled Operational Not operational Disabled Subsystem failure Card not present Slot disabled

Firmware statusThe operational status of the slot. The status conditions are:

Budgeted powerThe amount of inline power, in watts, that is reserved and available to the slot. Measured powerThe amount of power, in watts, that is currently being used by the slot.

Following is sample output from this command:


Inline Power Configured : System Power Surplus : Redundant Power Surplus : Power Usage Threshold : Disconnect Precedence : Legacy Mode : System Information Enabled 1500 Watts available for budgeting 465 Watts available for budgeting to maintain N+1 70 percent (per slot) lowest-priority Disabled Budgeted Measured Slot Inline-Power Firmware Status Power (Watts) Power (Watts) 3 Enabled Operational 50 W 9 W 4 Enabled Card Not Present ( 50 W) n/a 7 Enabled Operational 50 W 0 W Note: A budget value in parentheses is not allocated from the system power budget because the card is not present, or the slot is disabled.

174

ExtremeWare XOS 11.3 Concepts Guide

Displaying PoE Settings and Statistics

Displaying System Power Data


Additionally, you can view the distribution of power, as well as currently required and allocated power, on the entire switch including the power supplies by using the following command:
show power budget

Following is sample output from this command:


PS State Watts 48V 12V --------------------------------------------------------------------------1 Powered On 1152.00 1104.00 48.00 2 Powered On 1152.00 1104.00 48.00 3 Empty 4 Empty 5 Empty 6 Empty --------------------------------------------------------------------------Power Available: 2304.00 2208.00 96.00 Redundant (N+1) Power Available: 1200.00 1152.00 48.00 Slots Type State Watts 48V 12V --------------------------------------------------------------------------Slot-1 Empty Slot-2 Empty Slot-3 G48P Operational 111.00 110.00 1.00 Inline Power (budgeted + 2% loss) 51.00 51.00 0.00 Slot-4 G48P Empty Slot-5 G8X Operational 0.00 0.00 0.00 Slot-6 G48T Operational 0.00 0.00 0.00 Slot-7 G48P Operational 111.00 110.00 1.00 Inline Power (budgeted + 2% loss) 51.00 51.00 0.00 Slot-8 Empty Slot-9 Empty Slot-10 Empty MSM-A MSM-G8X Operational 151.00 150.00 1.00 MSM-B Empty 151.00 150.00 1.00 FanTray Operational 55.00 55.00 0.00 --------------------------------------------------------------------------Power Required: 681.00 677.00 4.00 Power Allocated: 681.00 677.00 4.00 Power Surplus: 1623.00 1531.00 92.00 Redundant Power Supply(s) Present?: yes

The term 2% loss shown in this display is the 2% associated with powering PDs. For example, when you reserve 50 W for a particular slot, the system reserves 51 W.

NOTE
Refer to the ExtremeWare XOS Command Reference Guide for more detailed explanation of the show power budget display.

ExtremeWare XOS 11.3 Concepts Guide

175

Power Over Ethernet

Displaying Slot PoE Information


You can display PoE status and statistics per slot.

Displaying Slot PoE Status


Use the following command to display PoE status for each slot:
show inline-power slot <slot>

The command provides the following information:

Inline power statusThe status of inline power. The status conditions are:

Enabled Disabled Operational Not operational Disabled Subsystem failure Card not present Slot disabled

Firmware statusThe operational status of the slot. The status conditions are:

Budgeted powerThe amount of power, in watts, that is available to the slot. Measured powerThe amount of power, in watts, that is currently being used by the slot.

Following is sample output from this command:


Slot 3 Inline-Power Enabled Firmware Status Operational Budgeted Power (Watts) 80 W Measured Power (Watts) 65 W

Displaying Slot PoE Statistics


Use the following command to display the PoE statistics for each slot:
show inline-power stats slot <slot>

The command provides the following information:

Firmware statusDisplays the firmware state:


Operational Not operational Disabled Subsystem failure Card not present Slot disabled

Firmware revisionDisplays the revision number of the PoE firmware. Total ports poweredDisplays the number of ports powered on specified slot. Total ports awaiting powerDisplays the number of remaining ports in the slot that are not powered.

176

ExtremeWare XOS 11.3 Concepts Guide

Displaying PoE Settings and Statistics


Total ports faultedDisplays the number of ports in a fault state. Total ports disabledDisplays the number of ports in a disabled state.

Following is sample output from this command:


Inline-Power Slot Statistics Slot: 3 Firmware status Firmware revision Total Total Total Total ports ports ports ports powered awaiting power faulted disabled

: Operational : 292b1 : : : : 17 31 0 0

Displaying Port PoE Information


You can display PoE configuration, status, and statistics per port.

Displaying Port PoE Configuration


Use the following command to display PoE configuration for each port:
show inline-power configuration ports <port_list>

This command provides the following information:

ConfigIndicates whether the port is enabled to provide inline power:


Enabled: The port can provide inline power. Disabled: The port cannot provide inline power.

Operator LimitDisplays the configured limit, in milliwatts, for inline power on the port. PriorityDisplays inline power priority of the port, which is used to determine which ports get power when there is insufficient power for all ports requesting power:

Low High Critical

LabelDisplays a text string, if any, associated with the port (15 characters maximum).

Following is sample output from this command:


Port 3:1 3:2 3:3 3:4 3:5 3:6 3:7 3:8 3:9 3:10 Config Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Operator 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 Limit mW mW mW mW mW mW mW mW mW mW Priority Low Low Low Low Low Low Low Low Low Low Label

ExtremeWare XOS 11.3 Concepts Guide

177

Power Over Ethernet

Displaying Port PoE Status


To display the PoE status per port, use the following command:
show inline-power info {detail} ports <port_list>

This command provides the following information:

StateDisplays the port power state:


Disabled Searching Delivering Faulted Disconnected Other Denied -----: disabled or searching class0: class 0 device class1: class 1 device class2: class 2 device class3: class 3 device class4: class 4 device

PDs power classDisplays the class type of the connected PD:


VoltsDisplays the measured voltage. A value from 0 to 2 is valid for ports that are in a searching or discovered state. CurrDisplays the measured current, in milliamperes, drawn by the PD. PowerDisplays the measured power, in watts, supplied to the PD. FaultDisplays the fault value:

None UV/OV fault UV/OV spike Over current Overload Undefined Underload HW fault Discovery resistance fail Operator limit violation Disconnect Discovery resistance, A2D failure Classify, A2D failure Sample, A2D failure Device fault, A2D failure Force on error

178

ExtremeWare XOS 11.3 Concepts Guide

Displaying PoE Settings and Statistics The detail command lists all inline power information for the selected ports. Detail output displays the following information:

Configured Admin State Inline Power State MIB Detect Status Label Operator Limit PD Class Max Allowed Power Measured Power Line Voltage Current Fault Status Detailed Status Priority

Following is sample output from the show inline-power info port command:
Port 3:1 3:2 3:3 State delivering delivering searching Class class3 class3 -----Volts 48.3 48.3 0.0 Curr (mA) 192 192 0 Power (Watts) 9.300 9.300 0.0 Fault None None None

Following is sample output from the show inline-power info detail port command:
Port 3:1 Configured Admin State: Inline Power State : MIB Detect Status : Label : Operator Limit : PD Class : Max Allowed Power : Measured Power : Line Voltage : Current : Fault Status : Detailed Status : Priority : enabled delivering delivering 16800 milliwatts class3 15.400 W 9.400 W 48.3 Volts 193 mA None low

Displaying Port PoE Statistics


Use the following command to display the PoE statistics for each port:
show inline-power stats ports <port_list>

ExtremeWare XOS 11.3 Concepts Guide

179

Power Over Ethernet The command provides the following information:

StateDisplays the port power state:


Disabled Searching Delivering Faulted Disconnected Other Denied -----: disabled or searching class0: class 0 device class1: class 1 device class2: class 2 device class3: class 3 device class4: class 4 device

PDs power classDisplays the class type of the connected PD:


AbsentDisplays the number of times the port was disconnected. InvSigDisplays the number of times the port had an invalid signature. DeniedDisplays the number of times the port was denied. Over-currentDisplays the number of times the port entered an overcurrent state. ShortDisplays the number of times the port entered undercurrent state.

Following is sample output from this command:


Port 3:1 3:2 3:3 3:4 3:5 3:6 3:7 3:8 3:9 3:10 State delivering delivering searching searching searching searching searching searching searching searching Class class3 class3 class0 class0 class0 class0 class0 class0 class0 class0 STATISTICS COUNTERS Absent InvSig Denied 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 OverCurrent 18 0 0 0 0 0 0 0 0 0 Short 0 0 0 0 0 0 0 0 0 0

180

ExtremeWare XOS 11.3 Concepts Guide

Status Monitoring and Statistics

This chapter describes the following topics:


Status Monitoring on page 181 Viewing Port Statistics on page 181 Viewing Port Errors on page 182 Using the Port Monitoring Display Keys on page 183 Diagnostics on page 184 System Health CheckingModular Switches Only on page 189 Setting the System Recovery Level on page 193 Viewing the System Temperature on page 195 Event Management System/Logging on page 197 Using sFlow on page 209 RMON on page 213

Viewing statistics on a regular basis allows you to see how well your network is performing. If you keep simple daily records, you can see trends emerging and notice problems arising before they cause major network faults. In this way, statistics can help you get the best out of your network.

Status Monitoring
The status monitoring facility provides information about the switch. This information may be useful for your technical support representative if you have a problem. ExtremeWare XOS includes many command line interface (CLI) show commands that display information about different switch functions and facilities. NOTE
For more information about show commands for a specific ExtremeWare XOS feature, see the appropriate chapter in this guide.

Viewing Port Statistics


ExtremeWare XOS provides a facility for viewing port statistical information. The summary information lists values for the current counter for each port on each operational module in the system. Beginning with ExtremeWare XOS 11.3, the switch automatically refreshes the display (this is the default behavior). You can also display a snapshot of the real-time port statistics at the time you issue the command and view the output in a page-by-page mode (this was the default behavior in ExtremeWare XOS 11.2 and earlier). This setting is not saved; therefore, you must specify the no-refresh parameter each time you want a snapshot of the port statistics.

ExtremeWare XOS 11.3 Concepts Guide

181

Status Monitoring and Statistics Values are displayed to nine digits of accuracy. To view port statistics, use the following command:
show ports {<port_list>} statistics {no-refresh}

The switch collects the following port statistical information:

Link StatusThe current status of the link. Options are:


Active (A)The link is present at this port. Ready (R)The port is ready to accept a link. Not Present (NP)The port is configured, but the module is not installed in the slot (modular switches only).

Transmitted Packet Count (Tx Pkt Count)The number of packets that have been successfully transmitted by the port. Transmitted Byte Count (Tx Byte Count)The total number of data bytes successfully transmitted by the port. Received Packet Count (Rx Pkt Count)The total number of good packets that have been received by the port. Received Byte Count (RX Byte Count)The total number of bytes that were received by the port, including bad or lost frames. This number includes bytes contained in the Frame Check Sequence (FCS), but excludes bytes in the preamble. Received Broadcast (RX Bcast)The total number of frames received by the port that are addressed to a broadcast address. Received Multicast (RX Mcast)The total number of frames received by the port that are addressed to a multicast address.

Viewing Port Errors


The switch keeps track of errors for each port. Beginning with ExtremeWare XOS 11.3, the switch automatically refreshes the display (this is the default behavior). You can also display a snapshot of the port errors at the time you issue the command and view the output in a page-by-page mode (this was the default behavior in ExtremeWare XOS 11.2 and earlier). This setting is not saved; therefore, you must specify the no-refresh parameter each time you want a snapshot of the port errors. To view port transmit errors, use the following command:
show ports {<port_list>} txerrors {no-refresh}

The switch collects the following port transmit error information:


Port NumberThe number of the port Link StatusThe current status of the link. Options are:

Active (A)The link is present at this port. Ready (R)The port is ready to accept a link. Not Present (NP)The port is configured, but the module is not installed in the slot (modular switches only).

182

ExtremeWare XOS 11.3 Concepts Guide

Using the Port Monitoring Display Keys

Transmit Collisions (TX Coll)The total number of collisions seen by the port, regardless of whether a device connected to the port participated in any of the collisions. Transmit Late Collisions (TX Late Coll)The total number of collisions that have occurred after the ports transmit window has expired. Transmit Deferred Frames (TX Deferred)The total number of frames that were transmitted by the port after the first transmission attempt was deferred by other network traffic. Transmit Errored Frames (TX Errors)The total number of frames that were not completely transmitted by the port because of network errors (such as late collisions or excessive collisions). Transmit Lost Frames (TX Lost)The total number of transmit frames that do not get completely transmitted because of buffer problems (FIFO underflow). Transmit Parity Frames (TX Parity)The bit summation has a parity mismatch.

To view port receive errors, use the following command:


show ports {<port_list>} rxerrors {no-refresh}

The switch collects the following port receive error information:


Port Number Link StatusThe current status of the link. Options are:

Active (A)The link is present at this port. Ready (R)The port is ready to accept a link. Not Present (NP)The port is configured, but the module is not installed in the slot (modular switches only).

Receive Bad CRC Frames (RX CRC)The total number of frames received by the port that were of the correct length but contained a bad FCS value. Receive Oversize Frames (RX Over)The total number of good frames received by the port greater than the supported maximum length of 1,522 bytes. Receive Undersize Frames (RX Under)The total number of frames received by the port that were less than 64 bytes long. Receive Fragmented Frames (RX Frag)The total number of frames received by the port that were of incorrect length and contained a bad FCS value. Receive Jabber Frames (RX Jabber)The total number of frames received by the port that were greater than the support maximum length and had a Cyclic Redundancy Check (CRC) error. Receive Alignment Errors (RX Align)The total number of frames received by the port with a CRC error and not containing an integral number of octets. Receive Frames Lost (RX Lost)The total number of frames received by the port that were lost because of buffer overflow in the switch.

Using the Port Monitoring Display Keys


Table 21 describes the keys used to control the displays that appear if you issue any of the show ports commands without specifying the no-refresh parameter (this is the default behavior).

ExtremeWare XOS 11.3 Concepts Guide

183

Status Monitoring and Statistics

Table 21: Port monitoring display keys with auto-refresh enabled


Key(s) U D [Esc] 0 [Space] Description Displays the previous page of ports. Displays the next page of ports. Exits from the screen. Clears all counters. Cycles through the following screens: Packets per second Bytes per second Percentage of bandwidth NOTE: Available only using the show ports utilization command.

Table 22 describes the keys used to control the displays that appear if you issue any of the show ports commands and specify the no-refresh parameter.

Table 22: Port monitoring displays keys with auto-refresh disabled


Key Q [Space] Description Exits from the screen. Displays the next page of ports.

Diagnostics
The switch provides a facility for running normal or extended diagnostics. On modular switches, you run the diagnostic routine on Input/Output (I/O) modules or Management Switch Fabric Modules (MSMs) without affecting the operation of the rest of the system. On the Summit X450 switch, you run the diagnostic routine on the switch. Running diagnostics affects system operation; the switch is unavailable during the diagnostic test. When you run diagnostics on an I/O module, MSM, or the Summit X450 switch, the switch verifies that the:

Registers can be written to and read from correctly Memory addresses are accessed correctly Application-Specific Integrated Circuit (ASICs) and Central Processing Unit (CPUs) operate as required Data and control fabric connectivity is active (modular switches only) External ports can send and receive packets Sensors, hardware controllers, and LEDs are working correctly NOTE

Before running slot diagnostics on a modular switch, you must have at least one MSM installed in the chassis.

184

ExtremeWare XOS 11.3 Concepts Guide

Diagnostics

Running Diagnostics on I/O and Management ModulesModular Switches Only


If you run the diagnostic routine on an I/O module, that module is taken offline while the diagnostic test is performed. Traffic to and from the ports on that I/O module is temporarily unavailable. When the diagnostic test is complete, the I/O module is reset and becomes operational again. If you run diagnostics on an MSM, that module is taken offline while the diagnostics test is performed. When the diagnostic test is complete, the MSM reboots and becomes operational again. After the switch runs the diagnostic routine, test results are saved in the modules EEPROM and messages are logged to the syslog. To run diagnostics on I/O or MSM modules, use the following command:
run diagnostics [extended | normal] slot [<slot> | A | B]

Where the following is true:

extendedTakes the switch fabric and ports offline and performs extensive ASIC, ASIC-memory,

and packet loopback tests. Extended diagnostic tests take a maximum of 15 minutes. The CPU is not tested. Console access is available during extended diagnostics.

normalTakes the switch fabric and ports offline and performs a simple ASIC and packet loopback test on all ports. <slot>Specifies the slot number of an I/O module. When the diagnostics test is complete, the system attempts to bring the I/O module back online.

NOTE
On the BlackDiamond 8810 switch (formerly known as Aspen), if you run diagnostics on slots 5 and 6 with an MSM installed in those slots, the diagnostic routine tests the I/O subsystem of the MSM. To run diagnostics on the management portion of the master MSM, specify slot A or B.

A | BSpecifies the slot letter of the master MSM. The diagnostic routine is performed when the system reboots. Both switch fabric and management ports are taken offline during diagnostics.

Running Diagnostics on the Summit X450 Switch Only


If you run the diagnostic routine on a Summit X450 switch, the switch reboots and then performs the diagnostic test. During the test, traffic to and from the ports on the switch is temporarily unavailable. When the diagnostic test is complete, the switch reboots and becomes operational again. After the switch runs the diagnostic routine, test results saved to the switchs EEPROM and messages are logged to the syslog. To run diagnostics on the Summit X450 switch, use the following command:
run diagnostics [extended | normal]

Where the following is true:

extendedReboots the switch and performs extensive ASIC, ASIC-memory, and packet loopback

tests. Extended diagnostic tests take a maximum of 5 minutes. The CPU is not tested.

normalReboots the switch and performs a simple ASIC and packet loopback test on all ports.

ExtremeWare XOS 11.3 Concepts Guide

185

Status Monitoring and Statistics

Observing LED Behavior During a Diagnostic Test


Whether you run a diagnostic test on an I/O module, an MSM, or a Summit X450 switch, LED activity occurs during and immediately following the test. The LED behavior described in this section relates only to the behavior associated with a diagnostic test. For more detailed information about all of the I/O module, MSM, and switch LEDs, see the Extreme Networks Consolidated XOS Hardware Installation Guide.

I/O Module LED BehaviorBlackDiamond 10K Switch


Table 23 describes the BlackDiamond 10K switch I/O module LED behavior during a diagnostic test.

Table 23: BlackDiamond 10K switch I/O module LED behavior


LED DIAG Status Color Amber blinking Amber Amber blinking Indicates Diagnostic test in progress. Diagnostic failure has occurred. Configuration error, code version error, diagnostic failure, or other severe module error.

After the I/O module completes the diagnostic test, or the diagnostic test is terminated, the DIAG and the Status LEDs are reset. During normal operation, the DIAG LED is off and the Status LED blinks green.

MSM LED BehaviorBlackDiamond 10K Switch


Table 24 describes the BlackDiamond 10K switch MSM LED behavior during a diagnostic test.

Table 24: BlackDiamond 10K switch MSM LED behavior


LED SYS Color Amber blinking Amber Indicates Diagnostic test in progress. Diagnostic failure has occurred.

After the MSM completes the diagnostic test, or the diagnostic test is terminated, the SYS LED is reset. During normal operation, the status LED blinks green.

I/O Module LED BehaviorBlackDiamond 8800 Family of Switches


Table 25 describes the BlackDiamond 8800 family of switches I/O module LED behavior during a diagnostic test.

Table 25: BlackDiamond 8800 family of switches I/O module LED behavior
LED DIAG Color Amber blinking Amber Green Stat Amber blinking Off Indicates Diagnostic test in progress. Diagnostic failure has occurred. Diagnostic test has passed. Configuration error, code version error, diagnostic failure, or other severe module error. Diagnostic test in progress, or diagnostic failure has occurred.

186

ExtremeWare XOS 11.3 Concepts Guide

Diagnostics After the I/O module completes the diagnostic test, or the diagnostic test is terminated, the DIAG and the Status LEDs are reset. During normal operation, the DIAG LED is off and the Status LED blinks green.

MSM LED BehaviorBlackDiamond 8800 Family of Switches


Table 26 describes the BlackDiamond 8800 family of switches MSM LED behavior during a diagnostic test on the primary MSM.

Table 26: BlackDiamond 8800 family of switches MSM LED behavior during diagnostic test on primary MSM
MSM Primary LED ERR Color Off Indicates Depending on the situation, this state indicates: Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Diagnostic failure has occurred. ENV Off Depending on the situation, this state indicates: Diagnostic test has passed. Diagnostic failure has occurred. Amber blinking Mstr/Diag Green/Off Off/Green Diagnostic test is in progress on the primary MSM. Diagnostic failure has occurred. Depending the situation, this state indicates: Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Sys/Stat Off/Off Depending on the situation, this state indicates: Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Amber/Green blinking Backup ERR Off Diagnostic failure has occurred. Depending on the situation, this state indicates: Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Diagnostic failure has occurred. ENV Off Depending on the situation, this state indicates: Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Diagnostic failure has occurred. Mstr/Diag Off/Off Green/Green Green/Off Sys/Stat Off/Green blinking Off/Off Amber/Green blinking Diagnostic failure has occurred. Diagnostic test in progress on the primary MSM. Diagnostic test has passed. Diagnostic test has passed. Diagnostic test in progress on the primary MSM. Diagnostic failure has occurred.

ExtremeWare XOS 11.3 Concepts Guide

187

Status Monitoring and Statistics Table 27 describes the BlackDiamond 8800 family of switches MSM LED behavior during a diagnostic test on the backup MSM.

Table 27: BlackDiamond 8800 family of switches MSM LED behavior during diagnostic test on backup MSM
MSM Backup LED ERR Color Off Indicates Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. ENV Off Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. Mstr/Diag Off/Green Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. Sys/Stat Primary ERR Off/Green Off/Off Amber Diagnostic test in progress on the backup MSM. Diagnostic test has passed. Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. ENV Off Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. Mstr/Diag Green/Off Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed. Sys/Stat Off/Green blinking Depending on the situation, this state indicates: Diagnostic test in progress on the backup MSM. Diagnostic test has passed.

LED BehaviorSummit X450 Switch


Table 28 describes the Summit X450 switch LED behavior during a diagnostic test.

Table 28: Summit X450 switch LED behavior


LED MGMT Color Green blinking Amber blinking Amber Indicates Normal operation is occurring. Diagnostic test in progress. Diagnostic failure has occurred.

While diagnostic tests are running, the MGMT LED blinks amber. If a diagnostic test fails, the MGMT LED goes to solid amber. During normal operation, the MGMT LED blinks green.

188

ExtremeWare XOS 11.3 Concepts Guide

System Health CheckingModular Switches Only

Displaying Diagnostic Test Results


To display the status of the last diagnostic test run on the switch, use the following command:
show diagnostics {slot [<slot> | A | B]}

NOTE
The slot, A, and B parameters are available only on modular switches.

System Health CheckingModular Switches Only


System health check is a useful tool to monitor the overall health of your system. The software performs a proactive, preventive search for problems by polling and reporting the health of system components, including I/O and management module processes, power supplies, power supply controllers, and fans. By isolating faults to a specific module, backplane connection, control plane, or component, the system health checker notifies you of a possible hardware fault. This section describes the system health check functionality of the following switches:

BlackDiamond 10K BlackDiamond 8800 family

Understanding the System Health CheckerBlackDiamond 10K Switch Only


The BlackDiamond 10K switch supports extensive error-checking and monitoring capabilities. Packet and system memories are protected by an error correction code (ECC). ECC is capable of correcting all single-bit errors and detecting all other memory errors. The data path is protected by checksums and parity checks. The system automatically corrects correctable memory errors and kills packets that encounter checksum and parity errors during processing. Errored packets are not propagated through the system. The primary responsibility of the system health checker is to monitor and poll the ASIC error registers. The system health checker processes, tracks, and reads the memory, parity, and checksum error counts. The ASICs maintain counts of correctable and uncorrectable memory errors, as well as packets that encountered checksum and parity errors. In a running system, some of these error counts may show non-zero values. Occasional increments of these counters does not mean faulty hardware is detected or that hardware requires replacement. If you see persistent increments of these counters, please contact Extreme Networks Technical Support. In addition, you can enable the system health checker to check the backplane, CPU, and I/O modules by periodically sending diagnostic packets and checking the validity of the looped back diagnostic packets. In summary, two modes of health checking are available: polling and backplane diagnostic packets. These methods are briefly described in the following:

Polling is always enabled on the system and occurs every 60 seconds by default. The system health checker polls and tracks the ASIC counters that collect correctable and uncorrectable packet memory errors, checksum errors, and parity errors on a per ASIC basis. By reading and processing the registers, the system health check detects and associates faults to specific system ASICs.

ExtremeWare XOS 11.3 Concepts Guide

189

Status Monitoring and Statistics

Backplane diagnostic packets are disabled by default. If you enable this feature, the system health checker tests the packet path for a specific I/O module every 6 seconds by default. The MSM sends and receives diagnostic packets from the I/O module to determine the state and connectivity. (The other I/O modules with backplane diagnostic packets disabled continue polling every 60 seconds by default.)

System health check errors are reported to the syslog. If you see an error, please contact Extreme Networks Technical Support.

Understanding the System Health CheckerBlackDiamond 8800 Family of Switches Only


On the BlackDiamond 8800 family of switches, the system health checker tests the backplane, the CPUs on the MSM modules, the I/O modules, the processes running on the switch, and the power supply controllers by periodically forwarding packets and checking for the validity of the forwarded packets. Two modes of health checking are available: polling (also known as control plane health checking) and backplane diagnostic packets (also known as data plane health checking). These methods are briefly described in the following:

Polling is always enabled on the system and occurs every 5 seconds by default. The polling value is not a user-configured parameter. The system health check polls the control plane health between MSMs and I/O modules, monitors memory levels on the I/O module, monitors the health of the I/O module, and checks the health of applications and processes running on the I/O module. If the system health checker detects an error, the health checker notifies the MSM. Backplane diagnostic packets are disabled by default. If you enable this feature, the system health checker tests the data link for a specific I/O module every 5 seconds by default. The MSM sends and receives diagnostic packets from the I/O module to determine the state and connectivity. If you disable backplane diagnostics, the system health checker stops sending backplane diagnostic packets.

System health check errors are reported to the syslog. If you see an error, please contact Extreme Networks Technical Support.

Enabling and Disabling Backplane Diagnostic Packets on the Switch


To enable backplane diagnostic packets, use the following command:
enable sys-health-check slot <slot>

BlackDiamond 10K switchBy default, the system health checker tests the packet path every 6 seconds for the specified slot. BlackDiamond 8800 family of switchesBy default, the system health checker tests the data link every 5 seconds for the specified slot. NOTE

Enabling backplane diagnostic packets increases CPU utilization and competes with network traffic for resources.

190

ExtremeWare XOS 11.3 Concepts Guide

System Health CheckingModular Switches Only To disable backplane diagnostic packets, use the following command:
disable sys-health-check slot <slot>

BlackDiamond 10K switchBy default, the system health checker discontinues sending backplane diagnostic packets and returns the polling frequency to 60 seconds on the specified slot. Only polling is enabled. BlackDiamond 8800 family of switchesBy default, the system health checker discontinues sending backplane diagnostic packets to the specified slot. Only polling is enabled.

Configuring Backplane Diagnostic Packets on the Switch


To configure the frequency of sending backplane diagnostic packets, use the following command:
configure sys-health-check interval <interval>

NOTE
Extreme Networks does not recommend configuring an interval of less than the default interval. Doing so can cause excessive CPU utilization.

System Health Check Examples


This section provides examples for using the system health checker on the BlackDiamond 10K switch and the BlackDiamond 8800 family of switches. For more detailed information about the system health check commands, see the chapter Commands for Status Monitoring and Statistics in the ExtremeWare XOS Command Reference Guide.

Examples on the BlackDiamond 10K Switch


This section contains a series of two examples for:

Enabling and configuring backplane diagnostics Disabling backplane diagnostics

Enabling and Configuring Backplane diagnostics. The following example:


Enables backplane diagnostic packets on slot 3 Modifies the polling interval from 60 seconds to 6 seconds Configures backplane diagnostic packets to be sent every 7 seconds and polling to occur every 7 seconds
enable sys-health-check slot 3

1 Enable backplane diagnostic packets on slot 3 using the following command: When you enable backplane diagnostic packets on slot 3, the polling timer changes from its current default value of 60 seconds to 6 seconds; 6 seconds is the default for sending backplane diagnostic packets. 2 Configure backplane diagnostic packets to be sent every 7 seconds and update the polling rate to 7 seconds using the following command:
configure sys-health-check interval 7

ExtremeWare XOS 11.3 Concepts Guide

191

Status Monitoring and Statistics

NOTE
Extreme Networks does not recommend configuring an interval of less than 6 seconds. Doing this can cause excessive CPU utilization.

Disabling Backplane Diagnostics. Building upon the previous example, the following example disables backplane diagnostics on slot 3:
disable sys-health-check slot 3

Backplane diagnostic packets are no longer sent, and the polling interval goes from 7 seconds to 70 seconds. To return to the "default" settings of sending backplane diagnostic packets every 6 seconds (when enabled) and polling the system every 60 seconds, specify 6 for the interval using the following command:
configure sys-health-check interval 6

Example on the BlackDiamond 8800 Family of Switches


This section contains a series of two examples for:

Enabling and configuring backplane diagnostics Disabling backplane diagnostics

Enabling and Configuring Backplane Diagnostics. The following example:


Enables backplane diagnostic packets on slot 3 Configures backplane diagnostic packets to be sent every 7 seconds
enable sys-health-check slot 3

1 Enable backplane diagnostic packets on slot 3 using the following command: When you enable backplane diagnostic packets on slot 3, the timer runs at the default rate of 5 seconds. 2 Configure backplane diagnostic packets to be sent every 7 seconds using the following command:
configure sys-health-check interval 7

NOTE
Extreme Networks does not recommend configuring an interval of less than 5 seconds. Doing this can cause excessive CPU utilization.

Disabling Backplane Diagnostics. Building upon the previous example, the following example disables backplane diagnostics on slot 3:
disable sys-health-check slot 3

Backplane diagnostic packets are no longer sent, but the configured interval for sending backplane diagnostic packets remains at 7 seconds. The next time you enable backplane diagnostic packets, the health checker sends the backplane diagnostics packets every 7 seconds.

192

ExtremeWare XOS 11.3 Concepts Guide

Setting the System Recovery Level To return to the "default" setting of 5 seconds, configure the frequency of sending backplane diagnostic packets to 5 seconds using the following command:
configure sys-health-check interval 5

Setting the System Recovery Level


Depending on your switch model, you can configure the switch, MSM, or I/O module to take action if a fault detection exception occurs. The following sections describe how to set the recovery level on the switch, MSM, and I/O modules. NOTE
You configure MSM and I/O module recovery only on the BlackDiamond 10K switch and the BlackDiamond 8800 family of switches.

Configuring System Recovery


You can configure the system either to take no action or to automatically reboot the switch after a software task exception, using the following command:
configure sys-recovery-level [all | none]

Where the following is true:

allConfigures ExtremeWare XOS to log an error into the syslog and automatically reboot the system after any task exception. noneConfigures the level to no recovery.

The default setting is all. Extreme Networks recommends using the default setting.

Displaying the System Recovery Setting


To display the system recovery setting on the switch, use the following command:
show switch

This command displays general switch information, including the system recovery level. The following truncated output displays the system recovery setting (displayed as Recovery Mode):
SysName: SysLocation: SysContact: System MAC: Recovery Mode: System Watchdog: TechPubs Lab support@extremenetworks.com, +1 888 257 3000 00:04:96:1F:A4:0E All Enabled

Configuring Module RecoveryModular Switches Only


You can configure the MSMs or I/O modules installed in the BlackDiamond 10K switch or the BlackDiamond 8800 family of switches to take no action, automatically reset, or if dual MSMs are

ExtremeWare XOS 11.3 Concepts Guide

193

Status Monitoring and Statistics installed, failover to the other MSM if the switch detects a faulty MSM or I/O module. This enhanced level of recovery detects faults in the ASICs as well as packet buses. To configure module recovery, use the following command:
configure sys-recovery-level slot <slot_number> [none | reset]

Where the following is true:

noneConfigures the MSM or I/O module to maintain its current state regardless of the detected

fault. The offending MSM or I/O module is not reset. ExtremeWare XOS logs fault and error messages to the syslog.

resetSpecifies that the offending MSM or I/O module be reset upon fault detection. ExtremeWare XOS logs fault, error, system reset, and system reboot messages to the syslog.

The default setting is reset. Extreme Networks recommends using the default setting. To get the most from module recovery, Extreme Networks recommends using the default settings for both system recovery and module recovery. The default setting for system recovery is all, and the default setting for module recovery is reset. For more information about system recovery, see Configuring System Recovery on page 193. By using the default settings, the switch resets the offending MSM or I/O module if fault detection occurs. An offending MSM is reset any number of times and is not permanently taken offline. On the BlackDiamond 10K switch, an offending I/O module is reset a maximum of three times. On the BlackDiamond 8800 family of switches, an offending I/O module is reset a maximum of five times. After the maximum number of resets, the I/O module is permanently taken offline.

Module Recovery Actions


Table 29 displays the actions module recovery takes when configured as reset (the default setting) in combination with the system recovery settings all and none.

Table 29: Module recovery actions


Module Recovery Setting and Hardware Configuration reset Single MSM Dual MSM System Recovery Setting and Action Taken all Resets the MSM. Resets the primary MSM and fails over to the backup MSM. BlackDiamond 10K switchResets the I/O module a maximum of three times. After the third time, the I/O module is permanently taken offline. BlackDiamond 8800 family of switchesResets the I/O module a maximum of five times. After the fifth time, the I/O module is permanently taken offline.

I/O Module

194

ExtremeWare XOS 11.3 Concepts Guide

Viewing the System Temperature

Table 29: Module recovery actions (Continued)


Module Recovery Setting and Hardware Configuration reset Single MSM Dual MSM I/O Module System Recovery Setting and Action Taken none Resets the MSM. Fails over to the backup MSM. Resets the I/O module.

Displaying the Module Recovery Setting


To display the module recovery setting, use the following command:
show slot

If you configure the module recovery setting to none, the output displays an E flag that indicates no corrective actions will occur for the specified MSM or I/O module. The E flag appears only if you configure the module recovery setting to none.

Troubleshooting Module Failures


If you experience an I/O module failure, use the following troubleshooting methods when you can bring the switch offline to solve or learn more about the problem:

Restarting the I/O moduleUse the disable slot <slot> command followed by the enable slot <slot> command to restart the offending I/O module. By issuing these commands, the I/O module and its associated fail counter is reset. If the module does not restart, or you continue to experience I/O module failure, please contact Extreme Networks Technical Support.

Running diagnosticsUse the run diagnostics normal <slot> command to run operational diagnostics on the offending I/O module to ensure that you are not experiencing a hardware issue. If the module continues to enter the failed state, please contact Extreme Networks Technical Support.

If you experience an MSM failure, please contact Extreme Networks Technical Support.

Viewing the System Temperature


Depending on your switch model, you can view the temperature in Celsius of the I/O modules, management modules, power controllers, power supplies, and fan trays installed in your switch. In addition, depending on the software version running on your switch, additional or different temperature information might be displayed. To view the system temperature, use the following command:
show temperature

System Temperature OutputModular Switches Only


On a modular switch, the output includes the current temperature and operating status of the I/O modules, management modules, and power controllers.

ExtremeWare XOS 11.3 Concepts Guide

195

Status Monitoring and Statistics The following sample output displays the current temperature and operating status of the installed modules and power controllers:
Field Replaceable Units Temp (C) Status -----------------------------------------------Slot-1 : 10G6X 36.37 Normal Slot-2 : G60X 35.31 Normal Slot-3 : Slot-4 : Slot-5 : Slot-6 : G60X 34.68 Normal Slot-7 : G60X 34.31 Normal Slot-8 : MSM-A : MSM-1XL 31.37 Normal MSM-B : MSM-1XL 29.75 Normal PSUCTRL-1 : PSUCTRL-2 : 29.00 Normal Temp Range: -10.00 (Min), 0.00-50.00 (Normal), 60.00 (Max)

The switch monitors the temperature of each component and generates a warning if the temperature exceeds the normal operating range. If the temperature exceeds the minimum/maximum limits, the switch shuts down the overheated module.

System Temperature OutputSummit X450 Switch Only


On a Summit X450 switch, the output includes the current temperature and operating status of the switch and the XGM-2xn card. The following sample output displays the current temperature and operating status of the switch:
Field Replaceable Units Temp (C) Status -----------------------------------------------Switch : SummitX450-24x 42.50 Normal XGM-2xn-1 : Temp Range: -10.00 (Min), 0.00-60.50 (Normal), 62.90 (Max)

The switch monitors its temperature and generates a warning if the temperature exceeds the normal operating range. If the temperature exceeds the maximum limit, the show switch output indicates the switch in an OPERATIONAL (Overheat) mode, and the show temperaturee output indicates an error state due to overheat.

Power Supply TemperatureModular Switches Only


To view the current temperature of the power supplies installed in a BlackDiamond 10K switch or the BlackDiamond 8800 family of switches, use the following command:
show power {<ps_num>} {detail}

The following sample output displays the temperature information:


PowerSupply 1 information: ...

196

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging


Temperature: ... 30.1 deg C

Fan Tray TemperatureBlackDiamond 10K Switch Only


To view the current temperature and status of the fan trays installed in the BlackDiamond 10K switch, use the following command:
show fans

The following sample output displays the fan tray temperature information on a BlackDiamond 10K switch:
Right(Rear-facing) FanTray 1 information: ... Temperature: 34.25 deg C ...

Event Management System/Logging


We use the general term, event, for any type of occurrence on a switch that could generate a log message or require an action. For example, a link going down, a user logging in, a command entered on the command line, or the software executing a debugging statement, are all events that might generate a log message. The system for saving, displaying, and filtering events is called the Event Management System (EMS). With EMS, you have many options about which events generate log messages, where the messages are sent, and how they are displayed. Using EMS you can:

Send event messages to a number of logging targets (for example, syslog host and NVRAM) Filter events per target, by:

Component, subcomponent, or specific condition (for example, BGP messages, IGMP.Snooping messages, or the IP.Forwarding.SlowPathDrop condition) Match expression (for example, any messages containing the string user5) Matching parameters (for example, only messages with source IP addresses in the 10.1.2.0/24 subnet) Severity level (for example, only messages of severity critical, error, or warning)

Change the format of event messages (for example, display the date as 12-May-2005 or 2005-0512) Display log messages in real time and filter the messages that are displayed, both on the console and from Telnet sessions Display stored log messages from the memory buffer or NVRAM Upload event logs stored in memory buffer or NVRAM to a TFTP server Display counts of event occurrences, even those not included in filter Display debug information using a consistent configuration method

Beginning with ExtremeWare XOS 11.2, EMS supports IPv6 as a parameter for filtering events.

ExtremeWare XOS 11.3 Concepts Guide

197

Status Monitoring and Statistics

Sending Event Messages to Log Targets


You can specify seven types of targets to receive log messages:

Console display Current session (Telnet or console display) Memory buffer (can contain 200 to 20,000 messages) NVRAM (messages remain after reboot) Primary MSM Backup MSM Syslog host

The first six types of targets exist by default; but before enabling any syslog host, you must add the hosts information to the switch using the configure syslog command. Extreme Networks EPICenter can be a syslog target. By default, the memory buffer and NVRAM targets are already enabled and receive messages. To start sending messages to the targets, use the following command:
enable log target [console | memory-buffer | nvram | primary-msm | backup-msm | session | syslog [all | <ipaddress> | <ipPort>] {vr <vr_name>} [local0 ... local7]]]

After you enable this feature, the target receives the messages it is configured for. See Target Configuration later in this chapter for information on viewing the current configuration of a target. The memory buffer can contain only the configured number of messages, so the oldest message is lost when a new message arrives, once the buffer is full. Use the following command to stop sending messages to the target:
disable log target [console | memory-buffer | nvram | primary-msm | backup-msm | session | syslog [all | <ipaddress> | <ipPort>] {vr <vr_name>} [local0 ... local7]]]

NOTE
Refer to your UNIX documentation for more information about the syslog host facility.

Dual MSM SystemsModular Switches Only


A system with dual MSMs keeps the two MSMs synchronized by executing the same commands on both. However, the full data between the EMS servers is not synchronized. The reason for this design decision is to make sure that the control channel will not be overloaded when a high number of log messages are generated. In order to capture events generated by one MSM onto the other MSM, there are two additional targets shown in the target commandsone called master-msm and one called backup-msm. The first target is active only on the non-primary (backup) EMS server and is used to send matching events to the primary EMS server. The other target is active only on the primary EMS server and is used to send matching events to all other EMS servers. If the condition for the backup-msm target is met by a message generated on the primary MSM, the event is sent to the backup MSM. When the backup MSM receives the event, it will see if any of the local targets (NVRAM, memory, or console) are matched. If so that event gets processed. The session

198

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging and syslog targets are disabled on the backup MSM, as they are handled on the primary. If the condition for the primary-msm target is met by a message generated on the backup, the event is sent to the primary MSM. Note that the backup-msm target is active only on the primary MSM, and the primary-msm target is active only on the backup MSM.

Filtering Events Sent to Targets


Not all event messages are sent to every enabled target. Each target receives only the messages that it is configured for.

Target Configuration
To specify the messages to send to an enabled target, you will set a message severity level, a filter name, and a match expression. These items determine which messages are sent to the target. You can also configure the format of the messages in the targets. For example, the console display target is configured to get messages of severity info and greater, the NVRAM target gets messages of severity warning and greater, and the memory buffer target gets messages of severity debug-data and greater. All the targets are associated by default with a filter named DefaultFilter, that passes all events at or above the default severity threshold. All the targets are also associated with a default match expression that matches any messages (the expression that matches any message is displayed as Match : (none) from the command line). And finally, each target has a format associated with it. To display the current log configuration of the targets, use the following command:
show log configuration target {console | memory-buffer | nvram | primary-msm | backupmsm | session | syslog {<ipaddress> | <ipPort> | vr <vr_name>} [local0 ... local7]}

To configure a target, you use specific commands for severity, filters, and formats. In addition, you can configure the source IP address for a syslog target. Configuring the source IP address allows the management station or syslog server to identify from which switch it received the log messages. To configure the source IP address for a syslog target, use the following command:
configure log target syslog [all | <ipaddress> | <ipPort>] {vr <vr_name>} {local0 ... local7} from <source-ip-address>

The following sections describe the commands required for configuring filters, formats, and severity.

Severity
Messages are issued with one of the severity levels specified by the standard Berkeley Software Distribution (BSD) syslog values (RFC 3164)critical, error, warning, notice, and infoplus three severity levels for extended debuggingdebug-summary, debug-verbose, and debug-data. Note that RFC 3164 syslog values emergency and alert are not needed because critical is the most severe event in the system.

ExtremeWare XOS 11.3 Concepts Guide

199

Status Monitoring and Statistics The three severity levels for extended debuggingdebug-summary, debug-verbose, and debug-data require that debug mode be enabled (which may cause a performance degradation). See Displaying Debug Information on page 209 for more information about debugging.

Table 30: Severity levels assigned by the switch


Level Critical Description A serious problem has been detected that is compromising the operation of the system; the system cannot function as expected unless the situation is remedied. The switch may need to be reset. A problem has been detected that is interfering with the normal operation of the system; the system is not functioning as expected. An abnormal condition, not interfering with the normal operation of the system, has been detected that indicate that the system or the network in general may not be functioning as expected. A normal but significant condition has been detected, which signals that the system is functioning as expected. A normal but potentially interesting condition has been detected, which signals that the system is functioning as expected; this level simply provides potentially detailed information or confirmation. A condition has been detected that may interest a developer seeking the reason underlying some system behavior. A condition has been detected that may interest a developer analyzing some system behavior at a more verbose level than provided by the debug summary information. A condition has been detected that may interest a developer inspecting the data underlying some system behavior.

Error Warning

Notice Info (Informational)

Debug-Summary Debug-Verbose Debug-Data

You can use more than one command to configure the severity level of the messages sent to a target. The most direct way to set the severity level of all the sent messages is to use the following command:
configure log target [console | memory-buffer | nvram | primary-msm | backup-msm | session | syslog [all | <ipaddress> | <ipPort> {vr <vr_name>} [local0 ... local7]]] {severity <severity> {only}}

When you specify a severity level, messages of that severity level and greater are sent to the target. If you want only those messages of the specified severity to be sent to the target, use the keyword only. For example, specifying severity warning will send warning, error, and critical messages to the target, but specifying severity warning only sends only warning messages. You can also use the following command to configure severity levels, which associate a filter with a target:
configure log target [console | memory-buffer | primary-msm | backup-msm | nvram | session | syslog [all | <ipaddress> | <ipPort> {vr <vr_name>} [local0 ... local7]]] filter <filter-name> {severity <severity> {only}}

When you specify a severity level as you associate a filter with a target, you further restrict the messages reaching that target. The filter may allow only certain categories of messages to pass. Only the messages that pass the filter and then pass the specified severity level reach the target. Finally, you can specify the severity levels of messages that reach the target by associating a filter with a target. The filter can specify exactly which message it will pass. Constructing a filter is described in Filtering By Components and Conditions on page 202.

200

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging

Components and Conditions


The event conditions detected by ExtremeWare XOS are organized into components and subcomponents. To get a listing of the components and subcomponents in your release of ExtremeWare XOS, use the following command:
show log components {<event component>} {version}

For example, to get a list of the components and subcomponents in your system, use the following command:
show log components

The partial output produced by the command is similar to the following:


Severity Component ------------------... ... STP InBPDU OutBPDU System ... ... Title Threshold ---------------------------------------------- -------------

Spanning-Tree Protocol (STP) STP In BPDU subcomponent STP Out BPDU subcomponent STP System subcomponent

Error Warning Warning Error

The display above lists the components, subcomponents, and the default severity threshold assigned to each. In EMS, you use A period (.) is used to separate component, subcomponent, and condition names. For example, you can refer to the InBPDU subcomponent of the STP component as STP.InBPDU. On the CLI, you can abbreviate or TAB complete any of these. A component or subcomponent often has several conditions associated with it. To see the conditions associated with a component, use the following command:
show log events [<event condition> | [all | <event component>] {severity <severity> {only}}] {details}

For example, to see the conditions associated with the STP.InBPDU subcomponent, use the following command:
show log events stp.inbpdu

The output produced by the command is similar to the following:


Comp ------STP STP STP STP STP SubComp ----------InBPDU InBPDU InBPDU InBPDU InBPDU Condition ----------------------Drop Dump Trace Ign Mismatch Severity Parameters ------------- ---------Error 2 total Debug-Data 3 total Debug-Verbose 2 total Debug-Summary 2 total Warning 2 total

The display above lists the five conditions contained in the STP.InBPDU component, the severity of the condition, and the number of parameters in the event message. In this example, the severities of the events in the STP.InBPDU subcomponent range from error to debug-summary.

ExtremeWare XOS 11.3 Concepts Guide

201

Status Monitoring and Statistics When you use the details keyword, you see the message text associated with the conditions. For example, if you want to see the message text and the parameters for the event condition STP.InBPDU.Trace, use the following command:
show log events stp.inbpdu.trace details

The output produced by the command is similar to the following:


Comp SubComp Condition Severity Parameters ------- ----------- ----------------------- ------------- ---------STP InBPDU Trace Debug-Verbose 2 total 0 - string 1 - string (printf) Port=%0%: %1%

The Comp heading shows the component name, the SubComp heading shows the subcomponent (if any), the Condition heading shows the event condition, the Severity heading shows the severity assigned to this condition, the Parameters heading shows the parameters for the condition, and the text string shows the message that the condition will generate. The parameters in the text string (for example, %0% and %1% above) will be replaced by the values of these parameters when the condition is encountered and displayed as the event message. Filtering By Components and Conditions. You may want to send the messages that come from a specific component that makes up ExtremeWare XOS or to send the message generated by a specific condition. For example, you might want to send only those messages that come from the STP component, or send the message that occurs when the IP.Forwarding.SlowPathDrop condition occurs. Or you may want to exclude messages from a particular component or event. To do this, you construct a filter that passes only the items of interest, and you associate that filter with a target. The first step is to create the filter using the create log filter command. You can create a filter from scratch, or copy another filter to use as a starting point. (It may be easiest to copy an existing filter and modify it.) To create a filter, use the following command:
create log filter <name> {copy <filter name>}

If you create a filter from scratch, that filter initially blocks all events until you add events (either the events from a component or a specific event condition) to pass. You might create a filter from scratch if you want to pass a small set of events and to block most events. If you want to exclude a small set of events, use the default filter that passes events at or above the default severity threshold (unless the filter has been modified), named DefaultFilter, that you can copy to use as a starting point for your filter. After you create your filter, you configure filter items that include or exclude events from the filter. Included events are passed; excluded events are blocked. To configure your filter, use the following command:
configure log filter <name> [add | delete] {exclude} events [<event-condition> | [all | <event-component>] {severity <severity> {only}}]

For example, if you create the filter myFilter from scratch, then issue the following command to include events:
configure log filter myFilter add events stp

All STP component events of at least the default threshold severity passes myFilter (for the STP component, the default severity threshold is error). You can further modify this filter by specifying additional conditions.

202

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging For example, assume that myFilter is configured as before, and assume that you want to exclude the STP.CreatPortMsgFail event. To add that condition, use the following command:
configure log filter myFilter add exclude events stp.creatportmsgfail

You can also add events and subcomponents to the filter. For example, assume that myFilter is configured as before, and you want to include the STP.InBPDU subcomponent. To add that condition, use the following command:
configure log filter myFilter add events stp.inbpdu

You can continue to modify this filter by adding more filter items. The filters process events by comparing the event with the most recently configured filter item first. If the event matches this filter item, the incident is either included or excluded, depending on whether the exclude keyword was used. if necessary, subsequent filter items on the list are compared. If the list of filter items is exhausted with no match, the event is excluded and is blocked by the filter. To view the configuration of a filter, use the following command:
show log configuration filter {<filter name>}

The output produced by the command (for the earlier filter) is similar to the following:
Log Filter I/ E Comp. - ------I STP E STP I STP Name: myFilter Sub-comp. Condition ----------- ----------------------InBPDU CreatPortMsgFail Severity CEWNISVD ---------------E-------------

Include/Exclude: Component Unreg: Severity Values: Debug Severity :

I - Include, E - Exclude * - Component/Subcomponent is not currently registered C - Critical, E - Error, W - Warning, N - Notice, I - Info S - Debug-Summary, V - Debug-Verbose, D - Debug-Data + - Debug Severities, but log debug-mode not enabled If Match parameters present: Parameter Flags: S - Source, D - Destination, (as applicable) I - Ingress, E - Egress, B - BGP Parameter Types: Port - Physical Port list, Slot - Physical Slot # MAC - MAC address, IP - IP Address/netmask, Mask - Netmask VID - Virtual LAN ID (tag), VLAN - Virtual LAN name L4 - Layer-4 Port #, Num - Number, Str - String Nbr - Neighbor, Rtr - Routerid, EAPS - EAPS Domain Proc - Process Name Strict Match : Y - every match parameter entered must be present in the event N - match parameters need not be present in the event

The show log configuration filter command shows each filter item, in the order that it will be applied and whether it will be included or excluded. The above output shows the three filter items, one including events from the STP.InBPDU component, one excluding the event STP.CreatPortMsgFail, and the next including the remaining events from the STP component. The severity value is shown as *, indicating that the components default severity threshold controls which messages are passed. The Parameter(s) heading is empty for this filter because no match is configured for this filter. Matches are described in Matching Expressions next.

ExtremeWare XOS 11.3 Concepts Guide

203

Status Monitoring and Statistics Each time a filter item is added to or deleted from a given filter, the specified events are compared against the current configuration of the filter to try to logically simplify the configuration. Existing items will be replaced by logically simpler items if the new item enables rewriting the filter. If the new item is already included or excluded from the currently configured filter, the new item is not added to the filter.

Matching Expressions
You can configure the switch so messages reaching the target match a specified match expression. The message text is compared with the configured match expression to determine whether to pass the message on. To require that messages match a match expression, use the following command:
configure log target [console | memory-buffer | nvram | primary-msm | backup-msm | session | syslog [all | <ipaddress> | <ipPort> {vr <vr_name>} [local0 ... local7]]] match [any |<match-expression>]

The messages reaching the target will match the match-expression, a simple regular expression. The formatted text string that makes up the message is compared with the match expression and is passed to the target if it matches. This command does not affect the filter in place for the target, so the match expression is compared only with the messages that have already passed the targets filter. For more information on controlling the format of the messages, see Formatting Event Messages on page 206. Simple Regular Expressions. A simple regular expression is a string of single characters including the dot character (.), which are optionally combined with quantifiers and constraints. A dot matches any single character, while other characters match only themselves (case is significant). Quantifiers include the star character (*) that matches zero or more occurrences of the immediately preceding token. Constraints include the caret character (^) that matches at the beginning of a message and the currency character ($) that matches at the end of a message. Bracket expressions are not supported. There are a number of sources available on the Internet and in various language references describing the operation of regular expressions. Table 31 shows some examples of regular expressions.

Table 31: Simple regular expressions


Regular Expression port Matches port 2:3 import cars portable structure baar bazaar rebar port 2:3 in vlan test add ports to vlan port/vlan delete myvlan error in myvlan myvlan port 2:3 ports 2:4,3:4 myvlan link down Does Not Match poor por pot bar

..ar

port.*vlan

myvlan$

Matching Parameters
Rather than using a text match, EMS allows you to filter more efficiently based on the parameter values of the message. In addition to event components and conditions and severity levels, each filter item can also use parameter values to further limit which messages are passed or blocked. The process of creating, configuring, and using filters has already been described in Filtering By Components and Conditions on page 202, so this section describes matching parameters with a filter item.

204

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging To configure a parameter match filter item, use the following command:
configure log filter <name> [add | delete] {exclude} events [<event-condition> | [all | <event-component>] {severity <severity> {only}}] [match | strict-match] <type> <value>

Each event in ExtremeWare XOS is defined with a message format and zero or more parameter types. The show log events all command can be used to display event definitions (the event text and parameter types). Only those parameter types that are applicable given the events and severity specified are exposed on the CLI. The syntax for the parameter types (represented by <type> in the command syntax above) is:
[address-family [ipv4-multicast | ipv4-unicast | ipv6-multicast | ipv6-unicast] | bgp-neighbor <ip address> | bgp-routerid <ip address> | eaps <eaps domain name> | {destination | source} [ipaddress <ip address> | L4-port <L4-port>| mac-address <mac-address>] | esrp <esrp domain name> | {egress | ingress} [slot <slot number> | ports <portlist>] | ipaddress <ip address> | L4-port <L4-port> | mac-address <mac_address> | netmask <netmask> | number <number> | port <portlist> | process <process name> | slot <slotid> | string <match expression> | vlan <vlan name> | vlan tag <vlan tag>]

Beginning with ExtremeWare XOS 11.2, you can specify the ipaddress type as IPv4 or IPv6, depending on the IP version. The following examples show how to configure IPv4 addresses and IPv6 addresses:

IPv4 address To configure an IP address, with a mask of 32 assumed, use the following command:
configure log filter myFilter add events all match ipaddress 12.0.0.1

To configure a range of IP addresses with a mask of 8, use the following command:


configure log filter myFilter add events all match ipaddress 12.0.0.0/8

IPv6 address To configure an IPv6 address, with a mask of 128 assumed, use the following command:
configure log filter myFilter add events all match ipaddress 3ffe::1

To configure a range of IPv6 addresses with a mask of 16, use the following command:
configure log filter myFilter add events all match ipaddress 3ffe::/16

IPv6 scoped address IPv6 scoped addresses consist of an IPv6 address and a VLAN. The following examples identify a link local IPv6 address. To configure a scoped IPv6 address, with a mask of 128 assumed, use the following command:
configure log filter myFilter add events all match ipaddress 3ffe::1%Default

ExtremeWare XOS 11.3 Concepts Guide

205

Status Monitoring and Statistics To configure a range of scoped IPv6 addresses with a mask of 16, use the following command:
configure log filter myFilter add events all match ipaddress 3ffe::/16%Default

To configure a scoped IPv6 address with any VLAN, use the following command:
configure log filter myFilter add events all match ipaddress 3ffe::/16%*

To configure any scoped IPv6 address with a specific VLAN, use the following command:
configure log filter myFilter add events all match ipaddress ::/0%Default

NOTE
In the previous example, if you specify the VLAN name, it must be a full match; wild cards are not allowed.

The <value> depends on the parameter type specified. As an example, an event may contain a physical port number, a source MAC address, and a destination MAC address. To allow only those RADIUS incidents, of severity notice and above, with a specific source MAC address, use the following command:
configure log filter myFilter add events aaa.radius.requestInit severity notice match source mac-address 00:01:30:23:C1:00

The string type is used to match a specific string value of an event parameter, such as a user name. A string can be specified as a simple regular expression. Match Versus Strict-Match. The match and strict-match keywords control the filter behavior for those incidents with event definition that does not contain all the parameters specified in a configure log filter events match command. This is best explained with an example. Suppose an event in the XYZ component, named XYZ.event5, contains a physical port number, a source MAC address, but no destination MAC address. If you configure a filter to match a source MAC address and a destination MAC address, XYZ.event5 will match the filter when the source MAC address matches regardless of the destination MAC address because the event contains no destination MAC address. If you specify the strict-match keyword, then the filter will never match event XYZ.event5 because this event does not contain the destination MAC address. In other words, if the match keyword is specified, an incident will pass a filter so long as all parameter values in the incident match those in the match criteria, but all parameter types in the match criteria need not be present in the event definition.

Formatting Event Messages


Event messages are made up of a number of items. The individual items can be formatted; however, EMS does not allow you to vary the order of the items. To format the messages for a particular target, use the following command:
configure log target [console | memory-buffer | nvram | session | syslog [all | <ipaddress> | <ipPort>] {vr <vr_name>} {local0 ... local7}]] format [timestamp [seconds | hundredths | none] | date [dd-mm-yyyy | dd-Mmm-yyyy | mm-dd-yyyy | Mmm-dd | yyyy-mm-dd | none] | severity | event-name [component | condition | none | subcomponent] | host-name | priority | process-name | process-slot | source-line

Using the default format for the session target, an example log message might appear as:
06/25/2004 22:49:10.63 <Info:dm.Info> MSM-A: PowerSupply:4 Powered On

206

ExtremeWare XOS 11.3 Concepts Guide

Event Management System/Logging If you set the current session format using the following command:
configure log target session format timestamp seconds date mm-dd-yyyy event-name component

The same example would appear as:


06/25/2004 22:49:10 <dm> PowerSupply:4 Powered On

To provide some detailed information to technical support, set the current session format using the following command:
configure log target session format timestamp hundredths date mmm-dd event-name condition process-name source-line

The same example then appears as:


Jun 25 22:49:10.63 <dm.info> devmgr: (dm.c:134) PowerSupply:4 Powered On

Displaying Real-Time Log Messages


You can configure the system to maintain a running real-time display of log messages on the console display or on a (Telnet) session. To turn on the log display on the console, use the following command:
enable log target console

This setting may be saved to the FLASH configuration and is restored on boot-up (to the console display session). To turn on log display for the current session:
enable log target session

This setting only affects the current session and is lost when you log off the session. The messages that are displayed depend on the configuration and format of the target. For information on message filtering, see Filtering Events Sent to Targets on page 199. for information on message formatting, see Formatting Event Messages on page 206.

Displaying Event Logs


The log stored in the memory buffer and the NVRAM can be displayed on the current session (either the console display or telnet). To display the log, use the following command:
show log {messages [memory-buffer | nvram]} {events {<event-condition> | <eventcomponent>]} {<severity> {only}} {starting [date <date> time <time> | date <date> | time <time>]} {ending [date <date> time <time> | date <date> | time <time>]} {match <regex>} {chronological}

You can use many options to select those log entries of interest. You can select to display only those messages that conform to the specified:

Severity Starting and ending date and time Match expression

ExtremeWare XOS 11.3 Concepts Guide

207

Status Monitoring and Statistics The displayed messages can be formatted differently from the format configured for the targets, and you can choose to display the messages in order of newest to oldest or in chronological order (oldest to newest).

Uploading Event Logs


The log stored in the memory buffer and the NVRAM can be uploaded to a TFTP server. Use the following command to upload the log:
upload log <ipaddress> {vr <vr_name>} <filename> {messages [memory-buffer | nvram] {events {<event-condition> | <event_component>}}} {<severity> {only}} {match <regex>} {chronological}

You must specify the TFTP host and the filename to use in uploading the log. There are many options you can use to select the log entries of interest. You can select to upload only those messages that conform to the specified:

Severity Match expression

The uploaded messages can be formatted differently from the format configured for the targets, and you can choose to upload the messages in order of newest to oldest or in chronological order (oldest to newest).

Displaying Counts of Event Occurrences


EMS adds the ability to count the number of occurrences of events. Even when an event is filtered from all log targets, the event is counted. To display the event counters, use the following command:
show log counters {<event condition> | [all | <event component>]} {include | notified | occurred} {severity <severity> {only}}}

The system displays two counters. One counter displays the number of times an event has occurred, and the other displays the number of times that notification for the event was made to the system for further processing. Both counters reflect totals accumulated since reboot or since the counters were cleared using the clear log counters or clear counters command. The show log counters command also displays an included flag (the column titled In in the output). The included flag is set to Y(es) if one or more targets are receiving notifications of this event without regard to matching parameters. The keywords include, notified, and occurred display events only with non-zero counter values for the corresponding counter. The output of the command:
show log counters stp.inbpdu severity debug-summary

is similar to the following:


Comp ------STP STP STP SubComp ----------InBPDU InBPDU InBPDU Condition ----------------------Drop Ign Mismatch Severity Occurred ------------- -------Error 0 Debug-Summary 0 Warning 0 In Notified -- -------Y 0 N 0 Y 0

208

ExtremeWare XOS 11.3 Concepts Guide

Using sFlow
Occurred : Flags : In(cluded): Notified : # of times this event has occurred since last clear or reboot (*) Not all applications responded in time with there count values Set to Y(es) if one or more targets filter includes this event # of times this event has occurred when 'Included' was Y(es)

The output of the command:


show log counters stp.inbpdu.drop

is similar to the following:


Comp SubComp Condition Severity Occurred ------- ----------- ----------------------- ------------- -------STP InBPDU Drop Error 0 Occurred : Flags : In(cluded): Notified : In Notified -- -------Y 0

# of times this event has occurred since last clear or reboot (*) Not all applications responded in time with there count values Set to Y(es) if one or more targets filter includes this event # of times this event has occurred when 'Included' was Y(es)

Displaying Debug Information


By default, a switch does not generate events of severity Debug-Summary, Debug-Verbose, and DebugData unless the switch is in debug mode. Debug mode causes a performance penalty, so it should only be enabled for specific cases where it is needed. To place the switch in debug mode, use the following command:
enable log debug-mode

Once the switch is in debug-mode, any filters configured for your targets still affect which messages are passed on or blocked.

Logging Configuration Changes


ExtremeWare XOS allows you to record all configuration changes and their sources that are made using the CLI by way of telnet or the local console. The changes cause events that are logged to the target logs. Each log entry includes the user account name that performed the change and the source IP address of the client (if telnet was used). Configuration logging applies only to commands that result in a configuration change. To enable configuration logging, use the following command:
enable cli-config-logging

To disable configuration logging, use the following command:


disable cli-config-logging

CLI configuration logging is disabled by default.

Using sFlow
sFlow is a technology for monitoring traffic in data networks containing switches and routers. It relies on statistical sampling of packets from high-speed networks, plus periodic gathering of the statistics. A User Datagram Protocol (UDP) datagram format is defined to send the information to an external entity

ExtremeWare XOS 11.3 Concepts Guide

209

Status Monitoring and Statistics for analysis. sFlow consists of a Management Information Base (MIB) and a specification of the packet format for forwarding information to a remote agent. Details of sFlow specifications can be found in RFC 3176, and specifications and more information can be found at the following website: http://www.sflow.org The ExtremeWare XOS implementation is based on sFlow version 5, which is an improvement from the revision specified in RFC 3176. Additionally, the switch hardware allows you to set the hardware sampling rate independently for each module on the switch, instead of requiring one global value for the entire switch. The switch software also allows you to set the individual port sampling rates, so you can fine-tune the sFlow statistics gathering. Per the RFC, sFlow sampling is done on ingress only.

NOTE
On the BlackDiamond 8800 family of switches, sFlow and mirroring are mutually exclusive. You can enable either sFlow, or mirroring, but not both.

However, you should be aware of a few limitations in the current release. The current release supports:

Generic port statistics reported to the sFlow collector Non-extended data Only those packets that do not match an ACL rule are considered for sampling Only port-based sampling No MIB support

Configuring sFlow
ExtremeWare XOS allows you to collect sFlow statistics on a per port basis. An agent, residing locally on the switch, sends data to a collector that resides on another machine. You configure the local agent, the address of the remote collector, and the ports of interest for sFlow statistics gathering. You can also modify default values for how frequently on average a sample is taken and the maximum number of samples allowed before throttling the sample gathering. To configure sFlow on a switch, you must do the following tasks:

Configure the local agent Configure the addresses of the remote collectors Enable sFlow globally on the switch Enable sFlow on the desired ports

Optionally, you may also change the default values of the following items:

How often the statistics are collected How frequently a sample is taken, globally or per port How many samples per second can be sent to the CPU

Configuring the Local Agent


The local agent is responsible for collecting the data from the samplers and sending that data to the remote collector as a series of UDP datagrams. The agent address is stored in the payload of the sFlow data, and is used by the sFlow collector to identify each agent uniquely. By default, the agent uses the

210

ExtremeWare XOS 11.3 Concepts Guide

Using sFlow management port IP address as its IP address. You change the agent IP address by using the following command:
configure sflow agent {ipaddress} <ip-address>

You unconfigure the agent using this command:


unconfigure sflow agent

Configuring the Remote Collector Address


You can specify up to four remote collectors to send the sFlow data to. Typically, you would configure the IP address of each collector. You may also specify a UDP port number different from the default value of 6343, and/or a virtual router different from the default of VR-Mgmt. When you configure a collector, the system creates a database entry for that collector that remains until the collector is unconfigured. All the configured collectors are displayed in the show sflow {configuration} command. Configure the remote collector using the following command:
configure sflow collector {ipaddress} <ip-address> {port <udp-port-number>} {vr <vrname>}

To unconfigure the remote collector and remove it from the database, use the following command:
unconfigure sflow collector {ipaddress} <ip-address> {port <udp-port-number>} {vr <vrname>}

Enabling sFlow Globally on the Switch


Before the switch will start sampling packets for sFlow, you must enable sFlow globally on the switch. To enable sFlow globally, use the following command:
enable sflow

You disable sFlow globally with the following command:


disable sflow

When you disable sFlow globally, the individual ports are also put into the disabled state. If you later enable the global sFlow state, individual ports return to their previous state.

Enabling sFlow on the Desired Ports


Enable sFlow on specific ports using the following command:
enable sflow ports <port_list>

You may enable and disable sFlow on ports irrespective of the global state of sFlow, but samples are not taken until both the port state and the global state are enabled. To disable sFlow on ports, use the following command:
disable sflow ports <portlist>

ExtremeWare XOS 11.3 Concepts Guide

211

Status Monitoring and Statistics

Additional sFlow Configuration Options


There are three global options that you can configure to different values from the defaults. These affect how frequently the sFlow data is sent to the remote collector, how frequently packets are sampled, and the maximum number of sFlow samples that could be processed in the CPU per second. You can also configure how frequently packets are sampled per port. Polling Interval. Each port counter is periodically polled to gather the statistics to send to the collector. If there is more than one counter to be polled, the polling is distributed in such a way that each counter is visited once during each polling interval, and the data flows are spaced in time. For example, assume that the polling interval is 20 seconds and there are 40 counters to poll. Two ports will be polled each second, until all 40 are polled. To configure the polling interval, use the following command:
configure sflow poll-interval <seconds>

Global Sampling Rate. This is the rate that newly enabled sFlow ports will have their sample rate set to. Changing this rate will not affect currently enabled sFlow ports. The default sample rate is 8192, so by default sFlow samples one packet out of every 8192 received. You configure the switch to use a different sampling rate with the following command:
configure sflow sample-rate <number>

For example, if you set the sample rate number to 16384, the switch samples one out of every 16384 packets received. Higher numbers mean fewer samples and longer times between samples. If you set the number too low, the number of samples can be very large, which increases the load on the switch. Do not configure the sample rate to a number lower than the default unless you are sure that the traffic rate on the source is low. Per Port Sampling Rate. You can set the sampling rate on individual ports, using the following command:
configure sflow ports <portlist> sample-rate <number>

For BlackDiamond 10KAt the hardware level, all ports on the same slot are sampled at the same rate, so if one port is configured to sample less frequently than another on the same slot, the extra samples are discarded. This is indicated in the output of the show sflow {configuration} command as the sub-sampling factor. For example, if one port is configured to sample one packet per every 8192 packets, and the second port on the same slot is configured to sample one packet per every 16384 packets, the second port will show a sub-sampling factor of two. For Summit X450At the hardware level, all ports on the switch are sampled at the same rate, so if one port is configured to sample less frequently than another, the extra samples are discarded. This is indicated in the output of the show sflow {configuration} command as the sub-sampling factor. For example, if one port is configured to sample one packet per every 8192 packets, and the second port on the same slot is configured to sample one packet per every 16384 packets, the second port will show a sub-sampling factor of two. Maximum CPU Sample Limit. A high number of samples can cause a heavy load on the switch CPU. To limit the load, there is a CPU throttling mechanism to protect the switch. Whenever the limit is reached, the sample rate value is doubled on the slot from which the maximum number of samples are received. For ports on that slot that are sampled less frequently, the sampling rate is not changed; the subsampling factor is adjusted downward. To configure the maximum CPU sample limit, use the following command:
configure sflow max-cpu-sample-limit <rate>

212

ExtremeWare XOS 11.3 Concepts Guide

RMON

Unconfiguring sFlow
You can reset the any configured values for sFlow to their default values and remove from sFlow any configured collectors and ports by using the following command:
unconfigure sflow

Displaying sFlow Information


To display the current configuration of sFlow, use the following command:
show sflow {configuration}

To display the sFlow statistics, use the following command:


show sflow statistics

RMON
Using the Remote Monitoring (RMON) capabilities of the switch allows network administrators to improve system efficiency and reduce the load on the network. The following sections explain more about the RMON concept and the RMON features supported by the switch.

NOTE
You can only use the RMON features of the system if you have an RMON management application and have enabled RMON on the switch.

About RMON
RMON is the common abbreviation for the Remote Monitoring Management Information Base (MIB) system defined by the Internet Engineering Task Force (IETF) documents RFC 1757 and RFC 2021, which allows you to monitor LANs remotely. A typical RMON setup consists of the following two components:

RMON agent Management workstation

RMON Agent
An RMON agent is an intelligent software agent that continually monitors port statistics and system variables. The agent transfers the information to a management workstation on request, or when a predefined threshold is crossed. Information collected by RMON includes Ethernet port statistics and history and the software version and hardware revision of the device. RMON generates alarms when threshold levels are met and then

ExtremeWare XOS 11.3 Concepts Guide

213

Status Monitoring and Statistics logs those events to the log. RMON can also send traps to the destination address configured by the management workstation. You can also use RMON to trigger a system reboot.

Management Workstation
A management workstation communicates with the RMON agent and collects the statistics from it. The workstation does not have to be on the same network as the RMON agent and can manage the agent by in-band or out-of-band connections. If you enable RMON on the switch, you can use a management workstation to review port statistics and port history, no configuration of the management workstation is necessary. However, you must use a management workstation to configure the alarm and event entries.

Supported RMON Groups of the Switch


The IETF defines nine groups of Ethernet RMON statistics. The switch supports the following four of these groups, as defined in RFC 1757:

Statistics History Alarms Events

The switch also supports the following parameters for configuring the RMON agent and the trap destination table, as defined in RFC 2021:

probeCapabilities probeSoftwareRev probeHardwareRev probeDateTime probeResetControl trapDestTable

The following sections describe the supported groups, the RMON probe configuration parameters, and the trap destination parameter in greater detail.

Statistics
The RMON Ethernet Statistics group provides traffic and error statistics showing packets, bytes, broadcasts, multicasts, and errors on an Ethernet port. Information from the Statistics group is used to detect changes in traffic and error patterns in critical areas of the network.

History
The History group provides historical views of network performance by taking periodic samples of the counters supplied by the Statistics group. The group features user-defined sample intervals and bucket counters for complete customization of trend analysis.

214

ExtremeWare XOS 11.3 Concepts Guide

RMON The group is useful for analysis of traffic patterns and trends on an Ethernet port, and to establish baseline information indicating normal operating parameters.

Alarms
The Alarms group provides a versatile, general mechanism for setting threshold and sampling intervals to generate events on any RMON variable. Both rising and falling thresholds are supported, and thresholds can be on the absolute value of a variable or its delta value. Please note, creating an entry in the alarmTable does not validate the alarmVariable and does not generate a badValue error message. Alarms inform you of a network performance problem and can trigger automated action responses through the Events group.

Events
The Events group creates entries in an event log and/or sends SNMP traps to the management workstation. An event is triggered by an RMON alarm. The action taken can be configured to ignore it, to log the event, to send an SNMP trap to the receivers listed in the trap receiver table, or to both log and send a trap. The RMON traps are defined in RFC 1757 for rising and falling thresholds. Effective use of the Events group saves you time. Rather than having to watch real-time graphs for important occurrences, you can depend on the Event group for notification. Through the SNMP traps, events can trigger other actions, which provides a mechanism for an automated response to certain occurrences.

RMON Probe Configuration Parameters


The RMON probe configuration parameters supported in ExtremeWare XOS are a subset of the probe configuration group as defined in RFC 2021. The probe configuration group controls and defines the operation of the RMON agent. You can configure the following objects:

probeCapabilitiesIf you configure the probeCapabilities object, you can view the RMON MIB groups supported on at least one interface by the probe. probeSoftwareRevIf you configure the probeSoftwareRev object, you can view the current software version of the monitored device. probeHardwareRevIf you configure the probeHardwareRev object, you can view the current hardware version of the monitored device. probeDateTimeIf you configure the probeDateTime object, you can view the current date and time of the probe. For example, Friday December 31, 2004 at 1:30:15 PM EST is displayed as: 2004-1231,13:30:15.0 If the probe is aware of time zones, the display also includes the Greenwich Mean Time (GMT) offset. For example, Friday, December 31, 2004, 1:30:15 PM EST with the offset known is displayed as: 2004-12-31,13:30:15.0, -4.0 If time information is unavailable or unknown, the time is not displayed.

probeResetControlIf you configure the probeResetControl object, you can restart a managed device that is not running normally. Depending on your configuration, you can do one of the following:

Warm bootA warm boot restarts the device using the current configuration saved in nonvolatile memory.

ExtremeWare XOS 11.3 Concepts Guide

215

Status Monitoring and Statistics

Cold bootA cold boot causes the device to reset the configuration parameters stored in nonvolatile memory to the factory defaults and then restarts the device using the restored factory default configuration.

trapDestTable
The trapDestTable contains information about the configured trap receivers on the switch and stores this information in non-volatile memory.To configure one or more trap receivers, see Using the Simple Network Management Protocol, in Chapter 3.

Configuring RMON
RMON requires one probe per LAN segment, and standalone RMON probes traditionally have been expensive. Therefore, the approach taken by Extreme Networks has been to build an inexpensive RMON probe into the agent of each system. This allows RMON to be widely deployed around the network without costing more than traditional network management. The switch accurately maintains RMON statistics at the maximum line rate of all of its ports. To enable or disable the collection of RMON statistics on the switch, use one of the following commands:
enable rmon disable rmon

By enabling RMON, the switch begins the processes necessary for collecting switch statistics. By default, RMON is disabled. However, even in the disabled state, the switch collects etherStats and you can configure alarms and events. RMON saves the history, alarm, and event configurations to the configuration file. Runtime data is not stored in the configuration file and is subsequently lost after a system restart.

Event Actions
The actions that you can define for each alarm are shown in Table 32.

Table 32: Event actions


Action no action log log-and-trap snmp-trap Sends a log message. Sends a both a log message and a trap to all trap receivers. Sends a trap to all trap receivers. High Threshold

To be notified of events using SNMP traps, you must configure one or more trap receivers, as described in the section, Using the Simple Network Management Protocol, in Chapter 3.

216

ExtremeWare XOS 11.3 Concepts Guide

RMON

Displaying RMON Information


To view the status of RMON polling on the switchthe enable/disable state for RMON pollinguse the following command:
show management

To view the RMON memory usage statistics for a specific RMON feature (for example, statistics, events, logs, history, or alarms) or for all features, use the following command:
show rmon memory {detail | <memoryType>}

ExtremeWare XOS 11.3 Concepts Guide

217

Status Monitoring and Statistics

218

ExtremeWare XOS 11.3 Concepts Guide

Virtual LANs

This chapter covers the following topics:


Overview of Virtual LANs on page 219 Types of VLANs on page 220 VLAN Names on page 228 Configuring VLANs on the Switch on page 229 Displaying VLAN Settings on page 230 Tunneling (VMANs) on page 232

Setting up Virtual Local Area Networks (VLANs) on the switch eases many time-consuming tasks of network administration while increasing efficiency in network operations.

Overview of Virtual LANs


NOTE
Beginning with ExtremeWare XOS 11.2, the software supports using IPv6 addresses, in addition to IPv4 addresses. You can configure the VLAN with an IPv4 address, IPv6 address, or both. See Chapter 24 for complete information on using IPv6 addresses.

The term VLAN is used to refer to a collection of devices that communicate as if they were on the same physical LAN. Any set of ports (including all ports on the switch) is considered a VLAN. LAN segments are not restricted by the hardware that physically connects them. The segments are defined by flexible user groups that you create with the command line interface (CLI).

Benefits
NOTE
The system switches traffic within each VLAN using the Ethernet MAC address. The system routes traffic between two VLANs using the IP addresses.

Implementing VLANs on your networks has the following advantages:

VLANs help to control trafficWith traditional networks, broadcast traffic that is directed to all network devices, regardless of whether they require it, causes congestion. VLANs increase the efficiency of your network because each VLAN can be set up to contain only those devices that must communicate with each other. VLANs provide extra securityDevices within each VLAN can communicate only with member devices in the same VLAN. If a device in VLAN Marketing must communicate with devices in VLAN Sales, the traffic must cross a routing device.

ExtremeWare XOS 11.3 Concepts Guide

219

Virtual LANs

VLANs ease the change and movement of devicesWith traditional networks, network administrators spend much of their time dealing with moves and changes. If users move to a different subnetwork, the addresses of each endstation must be updated manually.

Virtual Routers and VLANsBlackDiamond 10K Switch Only


NOTE
You create virtual routers only on the Black Diamond 10K switch; the BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch do not support user-created virtual routers.

ExtremeWare XOS supports virtual routers. Beginning with XOS version 11.2, each port can belong to multiple virtual routers; that is port can belong to more than one virtual router. Ports can belong to different VLANs that are in different virtual routers. If you do not specify a virtual router when you create a VLAN, the system creates that VLAN in the default virtual router (VR-Default). The management VLAN is always in the management virtual router (VR-Mgmt). Once you create virtual routers, ExtremeWare XOS software allows you to designate one of these virtual routers as the domain in which all your subsequent configuration commands, including VLAN commands, are applied. Once you create virtual routers, ensure that you are creating each VLAN in the desired virtual router domain. Also, ensure that you are in the correct virtual router domain before you begin modifying each VLAN. For information on configuring and using virtual routers, see Chapter 10.

Types of VLANs
NOTE
Beginning with ExtremeWare XOS version 11.3, you may have netlogin dynamic VLANs and, on the Summit X450 switch and BlackDiamond 8800 family of switches only, netlogin MAC-based VLANs. See Chapter 17 for complete information on netlogin.

VLANs can be created according to the following criteria:


Physical port IEEE 802.1Q tag Ethernet, LLC SAP, or LLC/SNAP Ethernet protocol type A combination of these criteria

Port-Based VLANs
In a port-based VLAN, a VLAN name is given to a group of one or more ports on the switch.

220

ExtremeWare XOS 11.3 Concepts Guide

Types of VLANs At boot-up, all ports are members of the port-based VLAN default. Before you can add any port to another port-based VLAN, you must remove it from the default VLAN, unless the new VLAN uses a protocol other than the default protocol any. A port can be a member of only one port-based VLAN. On the Extreme Networks switch in Figure 5, ports 9 through 14 are part of VLAN Marketing; ports 25 through 29 are part of VLAN Sales; and ports 21 through 24 and 30 through 32 are in VLAN Finance.

Figure 5: Example of a port-based VLAN on an Extreme Networks switch

Marketing

Finance

Sales

EX_060

For the members of different IP VLANs to communicate, the traffic must be routed by the switch, even if the VLANs are physically part of the same I/O module. This means that each VLAN must be configured as a router interface with a unique IP address. NOTE
On the BlackDiamond 10K switch, the 10 Gbps module must have the serial number 804405-00-09 or higher to support untagged frames. If your configuration has untagged frames, but the wrong 10 Gbps module, the system fails that slot; to use the earlier revision of the 10 Gbps module, you must remove the untagged ports from the VLAN and reset the module. To display the serial number of the module, issue the show slot <slot_number> command.

Spanning Switches with Port-Based VLANs


To create a port-based VLAN that spans two switches, you must do two things: 1 Assign the port on each switch to the VLAN. 2 Cable the two switches together using one port on each switch per VLAN. Figure 6 illustrates a single VLAN that spans a BlackDiamond switch and another Extreme Networks switch. All ports on the system 1 switch belong to VLAN Sales. Ports 1 through 29 on the system 2 switch also belong to VLAN Sales. The two switches are connected using slot 8, port 4 on system 1 (the BlackDiamond switch), and port 29 on system 2 (the other switch).

ExtremeWare XOS 11.3 Concepts Guide

221

Virtual LANs

Figure 6: Single port-based VLAN spanning two switches

Sales
System 1

System 2

EX_061

To create multiple VLANs that span two switches in a port-based VLAN, a port on system 1 must be cabled to a port on system 2 for each VLAN you want to have span across the switches. At least one port on each switch must be a member of the corresponding VLANs, as well. Figure 7 illustrates two VLANs spanning two switches. On system 2, ports 25 through 29 are part of VLAN Accounting; ports 21 through 24 and ports 30 through 32 are part of VLAN Engineering. On system 1, all port on slot 1 are part of VLAN Accounting; all ports on slot 8 are part of VLAN Engineering.

222

ExtremeWare XOS 11.3 Concepts Guide

Types of VLANs

Figure 7: Two port-based VLANs spanning two switches


System 1

Accounting
System 2

Engineering

EX_063

VLAN Accounting spans system 1 and system 2 by way of a connection between system 2, port 29 and system 1, slot 1, port 6. VLAN Engineering spans system 1 and system 2 by way of a connection between system 2, port 32, and system 1, slot 8, port 6. Using this configuration, you can create multiple port-based VLANs that span multiple switches, in a daisy-chained fashion. Each switch must have a dedicated port for each VLAN. Each dedicated port must be connected to a port that is a member of its VLAN on the next switch.

Tagged VLANs
Tagging is a process that inserts a marker (called a tag) into the Ethernet frame. The tag contains the identification number of a specific VLAN, called the VLANid (valid numbers are 1 to 4094). NOTE
The use of 802.1Q tagged packets may lead to the appearance of packets slightly bigger than the current IEEE 802.3/Ethernet maximum of 1,518 bytes. This may affect packet error counters in other devices and may also lead to connectivity problems if non-802.1Q bridges or routers are placed in the path.

Uses of Tagged VLANs


Tagging is most commonly used to create VLANs that span switches. The switch-to-switch connections are typically called trunks. Using tags, multiple VLANs can span multiple switches using one or more trunks. In a port-based VLAN, each VLAN requires its own pair of trunk ports, as shown in Figure 7. Using tags, multiple VLANs can span two switches with a single trunk.

ExtremeWare XOS 11.3 Concepts Guide

223

Virtual LANs Another benefit of tagged VLANs is the ability to have a port be a member of multiple VLANs. This is particularly useful if you have a device (such as a server) that must belong to multiple VLANs. The device must have a Network Interface Card (NIC) that supports IEEE 802.1Q tagging. A single port can be a member of only one port-based VLAN. All additional VLAN membership for the port must be accompanied by tags.

Assigning a VLAN Tag


Each VLAN may be assigned an 802.1Q VLAN tag. As ports are added to a VLAN with an 802.1Q tag defined, you decide whether each port will use tagging for that VLAN. The default mode of the switch is to have all ports assigned to the VLAN named default with an 802.1Q VLAN tag (VLANid) of 1 assigned. Not all ports in the VLAN must be tagged. As traffic from a port is forwarded out of the switch, the switch determines (in real time) if each destination port should use tagged or untagged packet formats for that VLAN. The switch adds and strips tags, as required, by the port configuration for that VLAN.

NOTE
Packets arriving tagged with a VLANid that is not configured on a port will be discarded.

Figure 8 illustrates the physical view of a network that uses tagged and untagged traffic.

Figure 8: Physical diagram of tagged and untagged traffic


M = Marketing S = Sales

System 1
M S

= Tagged port Marketing & Sales

802.1Q Tagged server

M M M S S S S

System 2
Figure 9 is a logical diagram of the same network.

EX_064

224

ExtremeWare XOS 11.3 Concepts Guide

Types of VLANs

Figure 9: Logical diagram of tagged and untagged traffic

Marketing
System 1 Ports 1-4 & 9-12 System 2 Slot 1, Port 2 Slot 2, Ports 1-8 & 17-24 System 1 Port 25 * Port 29 * System 2 Slot 1, Port 1 *

Sales
System 1 Ports 5-8, 13-16 & 32 System 2 Slot 1, Port 3 Slot 1, Port 4 Slot 2, Ports 9-16 & 25-32

*Tagged Ports
In Figure 8 and Figure 9:

EW_025

The trunk port on each switch carries traffic for both VLAN Marketing and VLAN Sales. The trunk port on each switch is tagged. The server connected to port 25 on system 1 has a NIC that supports 802.1Q tagging. The server connected to port 25 on system 1 is a member of both VLAN Marketing and VLAN Sales. All other stations use untagged traffic.

As data passes out of the switch, the switch determines if the destination port requires the frames to be tagged or untagged. All traffic coming from and going to the server is tagged. Traffic coming from and going to the trunk ports is tagged. The traffic that comes from and goes to the other stations on this network is not tagged.

Mixing Port-Based and Tagged VLANs


You can configure the switch using a combination of port-based and tagged VLANs. A given port can be a member of multiple VLANs, with the stipulation that only one of its VLANs uses untagged traffic. In other words, a port can simultaneously be a member of one port-based VLAN and multiple tagbased VLANs. NOTE
For the purposes of VLAN classification, packets arriving on a port with an 802.1Q tag containing a VLANid of zero are treated as untagged.

Protocol-Based VLANs
Protocol-based VLANs enable you to define a packet filter that the switch uses as the matching criteria to determine if a particular packet belongs to a particular VLAN. Protocol-based VLANs are most often used in situations where network segments contain hosts running multiple protocols. For example, in Figure 10, the hosts are running both the IP and NetBIOS protocols. The IP traffic has been divided into two IP subnets, 192.207.35.0 and 192.207.36.0. The subnets are internally routed by the switch. The subnets are assigned different VLAN names, Finance and Personnel,

ExtremeWare XOS 11.3 Concepts Guide

225

Virtual LANs respectively. The remainder of the traffic belongs to the VLAN named MyCompany. All ports are members of the VLAN MyCompany.

Figure 10: Protocol-based VLANs

192.207.35.1

192.207.36.1

My Company 192.207.35.0 Finance 192.207.36.0 Personnel

= IP traffic = All other traffic


EX_065

Predefined Protocol Filters


The following protocol filters are predefined on the switch:

IP (IPv4) IPv6 (11.2 IPv6) IPX NetBIOS DECNet IPX_8022 IPX_SNAP AppleTalk

Defining Protocol Filters


If necessary, you can define a customized protocol filter based on EtherType, Logical Link Control (LLC), and/or Subnetwork Access Protocol (SNAP). Up to six protocols may be part of a protocol filter. To define a protocol filter: 1 Create a protocol using the following command:
create protocol <name>

226

ExtremeWare XOS 11.3 Concepts Guide

Types of VLANs For example:


create protocol fred

The protocol name can have a maximum of 32 characters. 2 Configure the protocol using the following command:
configure protocol <name> add [etype | llc | snap] <hex> {[etype | llc | snap] <hex>} ...

Supported protocol types include:

etypeEtherType.

The values for etype are four-digit hexadecimal numbers taken from a list maintained by the IEEE. This list can be found at the following URL:
http://standards.ieee.org/regauth/ethertype/index.html

llcLLC Service Advertising Protocol (SAP).

The values for llc are four-digit hexadecimal numbers that are created by concatenating a twodigit LLC Destination SAP (DSAP) and a two-digit LLC Source SAP (SSAP).

snapEthertype inside an IEEE SNAP packet encapsulation.

The values for snap are the same as the values for etype, described previously. For example:
configure protocol fred add llc feff configure protocol fred add snap 9999

A maximum of 15 protocol filters, each containing a maximum of 6 protocols, can be defined. No more than 7 protocols can be active and configured for use.

NOTE
For more information on SNAP for Ethernet protocol types, see TR 11802-5:1997 (ISO/IEC) [ANSI/IEEE std. 802.1H, 1997 Edition].

Deleting a Protocol Filter


If a protocol filter is deleted from a VLAN, the VLAN is assigned a protocol filter of any. You can continue to configure the VLAN. However, no traffic is forwarded to the VLAN until a protocol is assigned to it.

Precedence of Tagged Packets Over Protocol Filters


If a VLAN is configured to accept tagged packets on a particular port, incoming packets that match the tag configuration take precedence over any protocol filters associated with the VLAN.

Default VLAN
The switch ships with one default VLAN that has the following properties:

The VLAN name is default. It contains all the ports on a new or initialized switch.

ExtremeWare XOS 11.3 Concepts Guide

227

Virtual LANs

The default VLAN is untagged on all ports. It has an internal VLANid of 1; this value is userconfigurable.

VLAN Names
Each VLAN is given a name that can be up to 32 characters. VLAN names use standard alphanumeric characters. VLAN names must begin with an alphabetical letter. The names can be no longer than 32 characters and must begin with an alphabetic character. The remainder of the name can be alphanumeric or contain underscore (_) characters. VLAN names cannot be keywords.

NOTE
If you use the same name across categories (for example, STPD and EAPS names), Extreme Networks recommends that you specify the identifying keyword as well as the actual name. If you do not use the keyword, the system may return an error message.

VLAN names can be specified using the tab key for command completion. VLAN names are locally significant. That is, VLAN names used on one switch are only meaningful to that switch. If another switch is connected to it, the VLAN names have no significance to the other switch.

NOTE
Extreme Networks recommends that you use VLAN names consistently across your entire network.

You must use mutually exclusive names for:


VLANs VMANs Ipv6 tunnels

Renaming a VLAN
To rename an existing VLAN, use the following command:
configure vlan <vlan_name> name <name>

The following rules apply to renaming VLANs:


You cannot change the name of the default VLAN. You cannot create a new VLAN named default.

228

ExtremeWare XOS 11.3 Concepts Guide

Configuring VLANs on the Switch

Configuring VLANs on the Switch


NOTE
On the BlackDiamond 10K switch, the 10 Gbps module must have the serial number 804405-00-09 or higher to support untagged frames. To display the serial number of the module, issue the show slot <slot_number> command.

This section describes the commands associated with setting up VLANs on the switch. Configuring a VLAN involves the following steps: 1 Create and name the VLAN. 2 Assign an IP address and mask (if applicable) to the VLAN, if needed. NOTE
Each IP address and mask assigned to a VLAN must represent a unique IP subnet. You cannot configure the same IP subnet on different VLANs on the same virtual router.

NOTE
If you plan to use this VLAN as a control VLAN for an EAPS domain, do NOT assign an IP address to the VLAN.

NOTE
Beginning with ExtremeWare XOS 11.2, the software supports using IPv6 addresses, in addition to IPv4 addresses. You can configure the VLAN with an IPv4 address, IPv6 address, or both. See Chapter 24for complete information on using IPv6 addresses.

3 Assign a VLANid, if any ports in this VLAN will use a tag. 4 Assign one or more ports to the VLAN. As you add each port to the VLAN, decide if the port will use an 802.1Q tag. 5 For management VLAN on the switch, configure the default iproute for virtual router VR-Mgmt. NOTE
See Chapter 23 for information on adding secondary IP addresses to VLANs.

VLAN Configuration Examples


NOTE
To add an untagged port to a VLAN you create, you must first delete that port from the default vlan. if you attempt to add an untagged port to a VLAN prior to deleting it from the default VLAN, you see the following error message: Error: Protocol conflict when adding untagged port 1:2. Either add this port as tagged or assign another protocol to this VLAN.

ExtremeWare XOS 11.3 Concepts Guide

229

Virtual LANs The following modular switch example creates a port-based VLAN:

Named accounting IPv4 address 132.15.121.1 Slot 2, ports 1, 2, 3, and 6, and slot 4, ports 1 and 2

create vlan accounting configure accounting ipaddress 132.15.121.1 configure default delete port 2:1-2:3,2:6,4:1,4:2 configure accounting add port 2:1-2:3,2:6,4:1,4:2

NOTE
Because VLAN names are unique, you do not need to enter the keyword vlan after you have created the unique VLAN name. You can use the VLAN name alone (unless you are also using this name for another category such as STPD or EAPS, in which case Extreme Networks recommends including the keyword vlan).

The following stand-alone switch example creates a port-based VLAN with an IPv6 address:

Named development IPv6 address 2001:DB8::8:800:200C:417A Ports 1, 2, and 3

create vlan development configure development ipaddress 2001:0DB8::8:800:200C:417A/64 configure default delete port 1-3 configure development add port 1-3

The following modular switch example creates a protocol-based VLAN named ipsales. Slot 5, ports 6 through 8, and slot 6, ports 1, 3, and 4-6 are assigned to the VLAN. In this example, you can add untagged ports to a new VLAN without first deleting them from the default VLAN, because the new VLAN uses a protocol other than the default protocol.
create vlan ipsales configure ipsales protocol ip configure ipsales add port 5:6-5:8,6:1,6:3-6:6

The following modular switch example defines a protocol filter, myprotocol and applies it to the VLAN named myvlan. This is an example only, and has no real-world application.
create protocol myprotocol configure protocol myprotocol add etype 0xf0f0 configure protocol myprotocol add etype 0xffff create vlan myvlan configure myvlan protocol myprotocol

Displaying VLAN Settings


NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support user-created virtual routers.

230

ExtremeWare XOS 11.3 Concepts Guide

Displaying VLAN Settings To display VLAN settings, use the following command:
show vlan {detail |<vlan_name> {stpd}}

The show command displays information about each VLAN, which includes:

Name VLANid How the VLAN was created Primary IPv4 address Secondary IP address (if configured) IPv6 addresses (if configured) Virtual router that VLAN belongs with IPX address (if configured). STPD information Protocol information QoS profile information Rate shaping information NetLogin information Ports assigned Tagged/untagged status for each port How the ports were added to the VLAN Number of VLANs configured on the switch EAPs information ESRP information IP forwarding information Multicasting information Routing protocol information

Use the detail option to display the detailed format.

NOTE
To display IPv6 information, you must issue either the show vlan detail command or show vlan command with the name of the specified VLAN.

You can display additional useful information on VLANs configured with IPv6 addresses by issuing the show ipconfig ipv6 vlan <vlan_name>. The following is sample output from this command:
BD10K # show ipconfig ipv6 my_ipv6_100 Router Interface on my_ipv6_100 is enabled and up. MTU: 1500 Locally registered unicast addresses: 2001:db8::8:802:200c:417a/64 fe80::230:48ff:fe41:ed97%my_ipv6_100/64 Flags: IPv6 Forwarding: YES Accept recvd RA: NO Send redirects: NO Accept redirects: NO

ExtremeWare XOS 11.3 Concepts Guide

231

Virtual LANs

Displaying Protocol Information


To display protocol information, use the following command:
show protocol {<name>}

This show command displays protocol information, which includes:


Protocol name Type Value

Tunneling (VMANs)
This section discusses how to configure the virtual metropolitan area network (VMAN) feature. The following topics are covered:

Overview on page 232 QoS Queue on Egress Port on page 234 Guidelines for Configuring VMANs on page 235 Configuring VMANs on page 235 Displaying VMAN Configurations on page 238

Overview
Beginning with ExtremeWare XOS software version 11.3, you can assign an IP address (including IPv6 addresses) to a specified VMAN. You assign an IP address to a specified VMAN using the following command (insert the VMAN name, rather than a VLAN name):
configure vlan <vlan_name> ipaddress [<ipaddress> {<ipNetmask>} | ipv6-link-local | {eui64} <ipv6_address_mask>]

You can tunnel any number of 802.1Q and/or Cisco ISL VLANs into a single VLAN that can be switched through an Extreme Networks Ethernet infrastructure. A given tunnel is completely isolated from other tunnels or VLANs. For the metropolitan area network (MAN) provider, the tagging numbers and methods used by the customer are transparent to the provider. You establish a private path through the public network using the Extreme Networks VMAN feature, which creates a bidirectional virtual data connection. A given tunnel switches Layer 2 traffic; the specified tunnel traffic is completely isolated from other traffic or tunnels. This feature is useful in building transparent private networks, or VMANs, that provide point-to-point or point-to-multipoint connectivity across an Ethernet infrastructure. Using encapsulation, the routing nodes in the public network are unaware that the transmission is part of a VMAN connection. To use the VMAN feature, you configure an encapsulation for all the traffic on the specified VMAN. The encapsulation allows the VMAN traffic to be switched over an Layer 2 infrastructure. To encapsulate the packet, the system adds a VMAN header that forms an outer VLAN header to the Ethernet frame. The traffic is switched through the infrastructure based on the VMAN header. The egress port of the entire VMAN removes the VMAN header, and the frame proceeds through the rest of the network with the original VLAN header.

232

ExtremeWare XOS 11.3 Concepts Guide

Tunneling (VMANs) VMAN is enabled on the ports in the tunnel. When VMAN is enabled on a network port, that port adds the VMAN tag to all ingressing frames, whether the frame is originally tagged or untagged. The Ethernet type configured for the VMAN header applies to the entire switch; this value cannot be configured per port. The default VMAN Ethernet type on Extreme Networks devices is 0x88a8. If your VMAN transits a third-party device (other than an Extreme Networks device), you must configure the EtherType as the Ethernet type that the third-party device uses. The system adds a 4-byte VMAN header on all packets, both originally tagged and untagged packets arriving at the VMAN port. Beginning with ExtremeWare XOS 11.3, the system supports all VMAN EtherTypes, including the standard VLAN Ethernet type of 0x8100. The VMAN tunnel begins at the ingress, or customer access, port and terminates at the egress, or trunk, port. Traffic flows from the egress trunk port onto the network thereafter without the VMAN tag. Ensure that all the switch-to-switch ports in the VMAN tunnel are configured as tagged ports. Configure the VMAN ingress, or customer access, port as an untagged port (although this port does accept tagged packets). You must configure the VMAN tunnel egress, or trunk, port as an untagged port so that the VMAN header is stripped from the frame.

NOTE
You must configure the VMAN tunnel egress, or trunk, port as untagged so that the VMAN header is stripped from the frame.

Each tunnel port that accesses the user can support (or belong to) only one VMAN tunnel; the remaining ports throughout the VMAN tunnel can support many VMANs.

VMANs on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
You must enable jumbo frames prior to configuring the VMANs on the BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch. On these switches, you enable jumbo frames on the entire switch; you cannot enable jumbo frames on separate ports. See Chapter 5 for more information on configuring jumbo frames on these devices. On the BlackDiamond 8800 family of switches, you cannot configure both VLANs and VMANs on the same slot; all ports on each slot must belong exclusively to either VLANs or VMANs. If you do configure both VLANs and VMANs on the same slot, the system returns an error message. The VMAN can span multiple modules, but you cannot configure VLANs and VMANs on the same module. On the Summit X450 switch, you cannot configure both VLANs and VMANs on the same switch; all ports on each discrete Summit X450 switch must belong exclusively to either VLANs or VMANs. You can configure the BlackDiamond 8800 family of switches and the Summit X450 switch to use the 802.1p value on the inner tag to direct the packet to the appropriate QoS queue on the egress port. See QoS Queue on Egress Port for more information on this feature.

VMANs on the BlackDiamond 10K Switch Only


The system automatically enables the specified ports for jumbo frames when you add ports to the VMANs.

ExtremeWare XOS 11.3 Concepts Guide

233

Virtual LANs On the BlackDiamond 10K switch, all ports added to a specified VMAN must be in the same virtual router. For more information on displaying, configuring, and using virtual routers, see Chapter 10. VMAN multicasting with IP addresses. Beginning with ExtremeWare XOS software version 11.3, you can assign an IP address to a specified VMAN to enable multicasting. To enable multicasting on the specified VMAN once you assigned an IP address, take the following steps: 1 Enable IP forwarding. 2 Enable IP multicast forwarding. 3 Enable and configure multicasting. NOTE
See Chapter 30 for information on configuring and using multicasting.

Once you enable multicast forwarding on the VMAN, you can configure and use PIM and IGMP snooping.

QoS Queue on Egress Port


The system can maintain any configured 802.1p priority contained on the original header of the packet. See Chapter 15 for more information on configuring the 802.1p priority.

Egress Queue on the BlackDiamond 10K Switch Only


On VMAN packets, the BlackDiamond 10K switch examines the packets inner 802.1p tag and then directs the packet to the appropriate egress queue on the egress port. This is not configurable.

Egress Queue on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
On the BlackDiamond 8800 family of switches and the Summit X450 switch, you can configure the switch to examine the packets inner 802.1p tag and use that value to direct the packet to the appropriate queue on the egress port. To configure this feature, issue the following command:
enable dot1p examination inner-tag port [all | <port_list>]

To return to the default value of ignoring the 802.1p value on the inner tag, issue the following command:
disable dot1p examination inner-tag port [all | <port_list>]

NOTE
See Chapter 15 for information on configuring and displaying the current 802.1p and DiffServ configuration for the inner, or original header, 802.1p value.

By default, the system on the BlackDiamond 8800 family of switches and the Summit X450 switch uses the 802.1p value on the outer VMAN header to direct the packet to the queue on the egress port.

234

ExtremeWare XOS 11.3 Concepts Guide

Tunneling (VMANs)

Guidelines for Configuring VMANs


The following are some guidelines for configuring VMANs:

Each tunnel port that accesses the user, or customer port, can support (or belong to) only one VMAN tunnel; the remaining ports throughout the VMAN tunnel can support many VMANs. Duplicate customers MAC address ingressing from multiple VMAN ports may disrupt the port learning association process in the switch. VMAN ports can belong to load-sharing groups. On the BlackDiamond 10K series of switches, if any port in the load-sharing group is enabled for VMAN, all ports in the group are automatically enabled to handle jumbo size frames. Also, VMAN is automatically enabled on all ports of the untagged load-sharing group.

You must use mutually exclusive names for:


VLANs VMANs Ipv6 tunnels

Configuring VMANs
You configure VMANs slightly differently on the BlackDiamond 10K switch and on the BlackDiamond 8800 family of switches and the Summit X450 switch.

Configuring VMANsBlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
NOTE
On the BlackDiamond 8800 family of switches, you cannot configure both VLANs and VMANs on the same slot; all ports on each slot must belong exclusively to either VLANs or VMANs. If you do configure both VLANs and VMANs on the same slot, the system returns an error message. The VMAN can span multiple modules, but the same module cannot have both VLANs and VMANs. Similarly, each discrete Summit X450 switch must have all ports belonging to either VLANs or VMANs; you cannot have VMAN and VLAN ports on the same switch.

Because the BlackDiamond 8800 family of switches and the Summit X450 switch enable jumbo frames switch-wide, you enable jumbo frames prior to configuring VMANs on that system. To configure a VMAN, follow these steps: 1 Enable jumbo frames on the switch. 2 Create the tunnel by creating the VMAN. 3 Assign a tag value to the VMAN. 4 Add the ports in the tunnel to the VMAN. 5 Configure VMAN member ports as tagged on switch-to-switch ports and untagged on the ingress and egress ports of the tunnel.

ExtremeWare XOS 11.3 Concepts Guide

235

Virtual LANs

NOTE
You must configure the VMAN tunnel egress, or trunk, port as untagged so that the VMAN header is stripped from the frame.

6 Configure the switch to use the 802.1p value on the inner tag to assign the packet to the appropriate egress queue on the egress port, if desired.

Configuring VMANsBlackDiamond 10K Switch Only


The BlackDiamond 10K switch automatically enables jumbo frames on the ports that you add to a VMAN. To configure a VMAN, follow these steps: 1 Create the tunnel by creating the VMAN. 2 Assign a tag value to the VMAN. 3 Add the ports in the tunnel to the VMAN. 4 Configure VMAN member ports as tagged on switch-to-switch ports and untagged on the ingress and egress ports of the tunnel. NOTE
You must configure the VMAN tunnel egress, or trunk, port as untagged so that the VMAN header is stripped from the frame.

5 If you want to configure multicasting on a specified VMAN, take the following steps: a Enable IP forwarding. a Enable IP multicasting forwarding. b Configure IGMP or PIM.

VMAN ExampleBlackDiamond 10K Switch


The follow example shows the steps to configure VMAN 1 on the Black Diamond 10808 switch shown in Figure 11. Beginning with ExtremeWare XOS software version, enable multicasting on the VMAN on the BlackDiamond 10K series switch.

236

ExtremeWare XOS 11.3 Concepts Guide

Tunneling (VMANs)

Figure 11: Sample VMAN configuration on BlackDiamond 10K switch

Engineering & Science Building

BlackDiamond 10808

BlackDiamond 6808
EX_101

The VMAN is from the building to port 1, slot 1 on the BlackDiamond 10808 switch and from port 1, slot 6 on the BlackDiamond 10808 switch to the BlackDiamond 6808 switch:
create vman vman_tunnel_1 configure vman vman_tunnel_1 tag 100 configure vman vman_tunnel_1 add port 1:1 untagged configure vman vman_tunnel_1 add port 6:1 tagged configure vman ipaddress 10.120.120.120.1/24 enable ipforwarding vman_tunnel_1 enable ipmcforwarding vman_tunnel_1

VMAN ExampleBlackDiamond 8810 Switch


The follow example shows the steps to configure VMAN 1 on the BlackDiamond 8810 switch shown in Figure 12.

Figure 12: Sample VMAN configuration on BlackDiamond 8810 switch

Engineering & Science Building

Aspen 8810

BlackDiamond 6808
XOS001

The VMAN is from the building to port 1, slot 3 on the BlackDiamond 8810 switch and from port 2, slot 3 on the BlackDiamond 8810 switch to the BlackDiamond 6808 switch:
enable jumbo frames create vman vman_tunnel_1 configure vman vman_tunnel_1 tag 100

ExtremeWare XOS 11.3 Concepts Guide

237

Virtual LANs
configure vman vman_tunnel_1 add port 3:1 untagged configure vman vman_tunnel_1 add port 3:2 tagged enable dot1p examination inner-tag port 3:2

Displaying VMAN Configurations


You can display the VMAN configuration and associated EAPS domains by issuing the show vman command. You can also display VMAN information, as well as all the VLANs, by issuing the show port information detail display. To display information on all VMANs, use the following command:
show vman

The following is sample output from the show vman command:


------------------------------------------------------------------------------Name VID Protocol Addr Flags Proto Ports Virtual Active router /Total ------------------------------------------------------------------------------peggy 100 10.10.255.3 /24 f-----m-------- ANY 0 /0 VR-Defaul t ------------------------------------------------------------------------------Flags : (C) EAPS Control vlan, (E) ESRP Enabled, (f) IP Forwarding Enabled, (i) ISIS Enabled, (I) IP Forwarding lpm-routing Enabled, (L) Loopback Enabled, (m) IPmc Forwarding Enabled, (n) IP Multinetting Enabled, (N) Network LogIn vlan, (o) OSPF Enabled, (p) PIM Enabled, (P) EAPS protected vlan, (r) RIP Enabled, (T) Member of STP Domain, (v) VRRP Enabled Total number of Vlan(s) : 6

To display information on a specific VMAN, use the following command


show vman <vlan_name>

The following is sample output from the show vman test command on a modular switch:
VLAN Interface with name test created by user Tagging:Untagged (Internal tag 4090) Priority: 802.1P Priority 0 Virtual router: VR-Default Primary IP : 10.10.255.3/24 IPv6: NONE STPD: None Protocol: Match all unfiltered protocols Loopback: Disable NetLogin: Enabled Rate Shape: Disable QosProfile: QP1 Ports: 2. (Number of active ports=2) Flags: (*) Active, (!) Disabled (g) Load Sharing port Untag: *3:1 Tag: *3:2

238

ExtremeWare XOS 11.3 Concepts Guide

Tunneling (VMANs) The display from the show vman detail command shows all the information shown in the show vman <vlan_name> command, but displays information for all configured VMANs. To display the EtherType, used the following command:
show vman etherType

The following is sample output from the show vman etherType command:
vMan EtherType: 0x88a8

ExtremeWare XOS 11.3 Concepts Guide

239

Virtual LANs

240

ExtremeWare XOS 11.3 Concepts Guide

10 Virtual Routers
This chapter describes the following topics:

Virtual Routers Overview on page 241 Using Virtual RoutersBlackDiamond 10K Switch Only on page 244

Creating Virtual Routers on page 244 Adding Ports to a Single Virtual Router on page 244 Adding Ports to Multiple Virtual Routers on page 245 Adding Routing Protocols to a Virtual Router on page 245

Virtual Router Configuration Example on page 246

Virtual Routers Overview


ExtremeWare XOS supports virtual routers. This capability allows a single physical switch to be split into multiple virtual routers. This feature separates the traffic forwarded by a virtual router from the traffic on a different virtual router. Each virtual router maintains a separate logical forwarding table, which allows the virtual routers to have overlapping IP addressing. Because each virtual router maintains its own separate routing information, packets arriving on one virtual router will never be switched to another. However, virtual routers should not be connected together through a Layer 2 domain. Since there is a single MAC address per switch in ExtremeWare XOS, this same MAC address is used for all virtual routers. If two virtual routers on same switch are connected through a Layer 2 domain, the intermediate Layer 2 switches will learn same MAC address of the switch on different ports, and may send traffic into the wrong virtual router. Ports on the switch can either be used exclusively by one virtual router, or can be shared among two or more virtual routers. One reason to configure a port for the exclusive use of a single virtual router is to be sure that only packets from that virtual router egress from that port. One reason to configure a port to be shared by multiple virtual routers is to pass traffic from multiple virtual routers across a shared link. With multiple virtual routers contained on a single physical switch, some commands in ExtremeWare XOS now require you to specify to which virtual router the command applies. For example, when you use the ping command, you must specify from which virtual router the ping packets are generated. Many commands that deal with switch management use the management virtual router by default. See the ExtremeWare XOS Command Reference Guide for information on the defaults for individual commands.

NOTE
The term virtual router is also used with the Virtual Router Redundancy Protocol (VRRP). VRRP uses the term to refer to a single virtual router that spans more than one physical router, which allows multiple switches to provide redundant routing services to users. For more information about VRRP, see Chapter 21.

ExtremeWare XOS 11.3 Concepts Guide

241

Virtual Routers

Types of Virtual Routers


There are two types of virtual routers in an ExtremeWare XOS system:

System virtual routers These are the special virtual routers created by ExtremeWare XOS during system boot up, and they cannot be deleted or renamed. There are a total of three of these special virtual routers in the ExtremeWare XOS system.

User virtual routers These are the virtual routers created and named by users. NOTE

User virtual routers are supported only on the BlackDiamond 10K switch.

System Virtual Routers


The system virtual routers are the three virtual routers created at boot-up time. These system virtual routers cannot be deleted or renamed. They are named VR-Mgmt, VR-Control, and VR-Default. The following describes each system virtual router:

VR-Mgmt VR-Mgmt enables remote management stations to access the switch through Telnet, SSH, and SNMP sessions; and it owns the management port. No other ports can be added to this VR-Mgmt, and the management port cannot be removed from it. The Mgmt VLAN is created in the VR-Mgmt during the ExtremeWare XOS system boot-up. No other VLAN can be created in this virtual router, and the Mgmt VLAN cannot be deleted from it. No routing protocol is running or can be added to this virtual router. This virtual router is called VR-0 in ExtremeWare XOS releases prior to 11.0.

VR-Control VR-Control is used for internal communications between all the modules and subsystems in the switch. It has no external visible ports, and you cannot assign any port to it. This virtual router, VR-Control, has no VLAN interface, and no VLAN can be created for it. No routing protocol is running or can be added to this virtual router. This virtual router is called VR-1 in ExtremeWare XOS releases prior to 11.0.

VR-Default VR-Default is the default virtual router created by the ExtremeWare XOS system. All data ports in the switch are assigned to this virtual router by default. Any data port can be added to and deleted from this virtual router. Users can create and delete VLANs in this virtual router. The Default VLAN is created in this virtual router during the ExtremeWare XOS system boot-up. The Default VLAN cannot be deleted from this virtual router. One instance of each routing protocol is spawned for this virtual router during the ExtremeWare XOS system boot-up, and these routing instances cannot be deleted. This virtual router is called VR-2 in ExtremeWare XOS releases prior to 11.0.

242

ExtremeWare XOS 11.3 Concepts Guide

Virtual Routers Overview

User Virtual RoutersBlackDiamond 10K Switch Only


User virtual routers are the virtual routers created by users in addition to the system virtual routers. The ability to create user virtual routers was first introduced in ExtremeWare XOS 11.0. When a new user virtual router is created, by default, no ports are assigned, no VLAN interface is created, and no support for any routing protocols is added.

Virtual Router Configuration DomainBlackDiamond 10K Switch Only


When you create virtual routers, you must configure each virtual router separately, configuring routing protocols and VLANs for each one. To simplify the configuration process, the concept of a virtual router configuration domain was introduced in ExtremeWare XOS 11.0. Under a virtual router configuration domain, any virtual router commands are applied only to that virtual router. The virtual router commands consist of all the BGP, OSPF, PIM and RIP commands, and the commands listed in Table 33.

Table 33: Virtual router commands


[enable | disable] ipforwarding clear iparp * clear counters iparp * configure iparp * configure iparp [add | delete] * [enable | disable] iparp * show iparp * configure iproute [add | delete] * show iproute * show ipstats * rtlookup create [vlan | vman] <vlan-name> [enable | disable] igmp [enable | disable] igmp snooping [enable | disable] ipmcforwarding show igmp show igmp snooping show igmp group show igmp snooping cache

* means that other commands are available with these listed. The virtual router configuration domain simplifies configuration because you do not have to specify the virtual router for each individual protocol configuration command. The current configuration domain is indicated in the command line interface (CLI) prompt by the name of the User virtual router, or no name if in the VR-Default domain.

ExtremeWare XOS 11.3 Concepts Guide

243

Virtual Routers

Using Virtual RoutersBlackDiamond 10K Switch Only


To use the user virtual router functionality in ExtremeWare XOS, you will need to do the following things:

Create the virtual router Configure ports to a single virtual router, or to multiple virtual routers Add any required routing protocols to the virtual router Configure the routing protocols and VLANs

The following sections describe how to do these tasks.

Creating Virtual Routers


To create a user virtual router, issue the following command:
create virtual-router <vr-name>

A virtual router name cannot be the same as a VLAN name. You cannot name a user virtual router with the names VR-Mgmt, VR-Control, or VR-Default because these are the existing default system virtual routers. For backward compatibility, user virtual routers also cannot be named VR-0, VR-1 or VR-2, because these three names are the names for the system virtual routers in ExtremeWare XOS releases prior to 11.0. To delete a user virtual router, issue the following command:
delete virtual-router <vr-name>

Before you delete a virtual router, you must delete all VLANs created in that virtual router. All of the ports assigned to this virtual router will be deleted and made available to assign to other virtual routers. Any routing protocol that is running on the virtual router will be shut down and deleted gracefully.

Configuring Ports to a Single or to Multiple Virtual Router(s)


By default, all the user data ports belong to the system default virtual router, VR-Default, and belong to the default VLAN, Default. All these ports are used exclusively by the virtual router, VR-Default. To configure a port for exclusive use by another virtual router, or for use by multiple virtual routers, it must first be deleted from VR-Default. You must delete the port from any VLAN it belongs to before deleting it from a virtual router. To delete a port from a virtual router, issue the following command:
configure vr <vr-name> delete ports <portlist>

Adding Ports to a Single Virtual Router


When you add a port to a virtual router, that port can only be used by that virtual router. To add a port to a single virtual router, use the following command:
configure vr <vr-name> add ports <portlist>

244

ExtremeWare XOS 11.3 Concepts Guide

Using Virtual RoutersBlackDiamond 10K Switch Only The following is an example of removing all the ports on slot 3 from the default VLAN in the default virtual router and adding them for the exclusive use of the virtual router helix:
configure vlan default delete ports 3:* configure vr vr-default delete ports 3:* configure vr helix add ports 3:*

Adding Ports to Multiple Virtual Routers


A port is available to be configured for multiple virtual routers after it has been deleted from the default virtual router, VR-Default. To use a port in multiple virtual routers, do not add the port to a virtual router, as you would in the previous section, Adding Ports to a Single Virtual Router, just add the port to a VLAN in the desired virtual router. NOTE
See Chapter 15 for details about how multiple virtual routers per port can affect DiffServ and code replacement.

In the following example we add port 3:5 to the virtual routers VR-green and VR-blue. Weve already created the tagged VLAN bldg_200 in VR-green, and the tagged VLAN bldg_300 in VR-blue.
configure configure configure configure vlan default delete ports 3:5 vr vr-default delete ports 3:5 vlan bldg_200 add ports 3:5 tagged vlan bldg_300 add ports 3:5 tagged

Adding Routing Protocols to a Virtual Router


Unlike the default system virtual router, VR-Default, there are no resources allocated for routing protocols when a user virtual router is created. You must add the routing protocols needed for your virtual router before you attempt to configure them. When you add a protocol to a user virtual router, a process is started to support the protocol. Adding a protocol to a virtual router does not enable that protocol. You must then specifically enable and configure any protocol that you add. To add a protocol to a virtual router, use the following command:
configure vr <vr-name> add protocol <protocol-name>

To remove a protocol from a virtual router, use the following command:


configure vr <vr-name> delete protocol <protocol-name>

Displaying Ports and Protocols


You display the ports, protocols, and the name of the protocol processes for a virtual router by using the following command:
show virtual-router {<vr-name>}

ExtremeWare XOS 11.3 Concepts Guide

245

Virtual Routers

Configuring the Routing Protocols and VLANs


Once the virtual router is created, the ports are added, and support for any needed routing protocols is added, you can configure the virtual router. To simplify configuring the user virtual routers, the concept of a virtual router configuration domain was added (instead of adding a virtual router keyword to every command in every routing protocol). Virtual router commands are applied to the current configuration domain. The virtual router commands consist of all the BGP, OSPF, PIM and RIP commands, as well as the create vlan and delete vlan commands. Other commands apply to the switch as a whole. To enter a virtual router configuration domain, use the following command:
virtual-router {<vr-name>}

For example, to enter the configuration domain for the virtual router helix, your CLI session would look similar to this:
* BD10K.13 # virtual-router helix * (vr helix) BD10K.14 #

The CLI prompt displays the virtual router configuration domain. Use the virtual-router command with no virtual router name, or use the name VR-Default to return to the default configuration domain. Now you can create VLANs, using the following command:
create vlan <vlan_name> {vr <vr-name>}

If you do not specify a virtual router in the create vlan command, the VLAN is created in the virtual router of the current configuration domain.

NOTE
All VLAN names and VLAN IDs on a switch must be unique, regardless of the virtual router they are created in. You cannot have two VLANs with the same name, even if they are in different virtual routers.

You can also configure routing protocols, by using the standard ExtremeWare XOS commands. The routing configurations of the different virtual routers are independent of each other.

Virtual Router Configuration Example


In the following example:

The user virtual router helix is created Ports are removed from the VLAN Default and the virtual router VR-Default Ports are added to the virtual router helix OSPF is added to the virtual router helix The configuration domain is set to helix, so that subsequent virtual router commands affect the virtual router helix

246

ExtremeWare XOS 11.3 Concepts Guide

Virtual Router Configuration Example


The VLAN helix-accounting is created Ports that belong to the virtual router helix are added to the VLAN helix-accounting

The CLI prompt is shown in this example to show how the virtual router configuration domain is displayed. At the end of the example, the virtual router is ready to be configured for OSPF, using ExtremeWare XOS commands.
* * * * * * * * * BD10K.1 # create virtual-router helix BD10K.2 # configure vlan default delete ports 3:* BD10K.3 # configure vr vr-default delete ports 3:* BD10K.4 # configure vr helix add ports 3:* BD10K.5 # configure vr helix add protocol ospf BD10K.6 # virtual-router helix (vr helix) BD10K.7 # create vlan helix-accounting (vr helix) BD10K.8 # configure helix-accounting add ports 3:1 (vr helix) BD10K.9 #

ExtremeWare XOS 11.3 Concepts Guide

247

Virtual Routers

248

ExtremeWare XOS 11.3 Concepts Guide

11 Forwarding Database
This chapter describes the following topics:

Overview of the FDB on page 249 FDB Configuration Examples on page 251 Configuring the FDB Aging Time on page 252 Displaying FDB Entries on page 252 MAC-Based Security on page 253 Multicast FDB with Multiport EntrySummit X450 Switch and BlackDiamond 8800 Chassis Only on page 256

Overview of the FDB


NOTE
See the ExtremeWare XOS Command Reference Guide for details of the commands related to the FDB.

The switch maintains a database of all MAC addresses received on all of its ports. It uses the information in this database to decide whether a frame should be forwarded or filtered. This section covers the following topics:

FDB Contents on page 249 How FDB Entries Get Added on page 250 FDB Entry Types on page 250

FDB Contents
Each Forwarding Database (FDB) entry consists of:

The MAC address of the device An identifier for the port and VLAN on which it was received The age of the entry Flags

Frames destined for MAC addresses that are not in the FDB are flooded to all members of the VLAN.

ExtremeWare XOS 11.3 Concepts Guide

249

Forwarding Database

How FDB Entries Get Added


Entries are added into the FDB in the following ways:

The switch can learn entries by examining packets it receives. The system updates its FDB with the source MAC address from a packet, the VLAN, and the port identifier on which the source packet is received. The ability to learn MAC addresses can be enabled or disabled on a port-by-port basis. You can also limit the number of addresses that can be learned, or you can lock down the current entries and prevent additional MAC address learning. NOTE

For more information on port control for learning MAC address, refer to Chapter 5.

You can enter and update entries using the command line interface (CLI). Certain static entries are added by the system upon switch boot-up.

FDB Entry Types


FDB entries may be dynamic or static, and the entries may be permanent or non-permanent. The following describes the types of entries that can exist in the FDB:

Dynamic entriesA dynamic entry is learned by the switch by examining packets to determine the source MAC address, VLAN, and port information. The switch then creates or updates an FDB entry for that MAC address. Initially, all entries in the database are dynamic, except for certain entries created by the switch at boot-up. Entries in the database are removed (aged-out) if, after a period of time (aging time), the device has not transmitted. This prevents the database from becoming full with obsolete entries by ensuring that when a device is removed from the network, its entry is deleted from the database. Dynamic entries are flushed and relearned (updated) when any of the following take place:

A VLAN is deleted. A VLAN identifier (VLANid) is changed. A port mode is changed (tagged/untagged). A port is deleted from a VLAN. A port is disabled. A port enters blocking state. A port goes down (link down).

A non-permanent dynamic entry is initially created when the switch identifies a new source MAC address that does not yet have an entry in the FDB. The entry may then be updated as the switch continues to encounter the address in the packets it examines. These entries are identified by the d flag in show fdb output. Dynamic entries agethat is, a dynamic entry is removed from the FDB (aged-out) if the device does not transmit for a specified period of time (the aging time). This aging process prevents the FDB from becoming full with obsolete entries by ensuring that when a device is removed from the network, its entry is deleted from the database. The aging time is configurable. For more information about setting the aging time, see Configuring the FDB Aging Time on page 252.

250

ExtremeWare XOS 11.3 Concepts Guide

FDB Configuration Examples

Static entriesA static entry does not age and does not get updated through the learning process. A static entry is maintained exactly as it was created. Conditions that cause dynamic entries to be updated, such as VLAN or port configuration changes, do not affect static entries. A locked static entry is an entry that was originally learned dynamically, but has been made static (locked) using the MAC address lock-down feature. It is identified by the s, p, and l flags in show fdb output and can be deleted using the delete fdbentry command. See MAC Address Lock Down on page 317 for more information about MAC address lock-down. If the FDB entry aging time is set to zero, all entries in the database are considered static, non-aging entries. This means that the entries do not age, but they are still deleted if the switch is reset. NOTE

On the BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch, if the same MAC address is detected on another virtual port that is not defined in the static FDB entry for the MAC address, that address is handled as a blackhole entry.

Permanent entriesPermanent entries are retained in the database if the switch is reset or a power off/on cycle occurs. Permanent entries must be created by the system administrator through the CLI. Permanent entries are static, meaning they do not age or get updated.

FDB Configuration Examples


This section covers the following topics:

Adding a Permanent Static Entry on page 251 Configuring the FDB Aging Time on page 252 Clearing FDB Entries on page 252

Adding a Permanent Static Entry


The following example adds a permanent static entry to the FDB:
create fdbentry 00:E0:2B:12:34:56 vlan marketing port 3:4

The permanent entry has the following characteristics:


MAC address is 00:E0:2B:12:34:56. VLAN name is marketing. Slot number for this device is 3 (only on modular switches). Port number for this device is 4. NOTE

On the BlackDiamond 8800 family of switches and the Summit X450 switch, if the MAC address 00:E0:2B:12:34:56 is encountered on any port/VLAN other than VLAN marketing, port 3:4, that address will be handled as a blackhole entry, and packets from that source will be dropped.

ExtremeWare XOS 11.3 Concepts Guide

251

Forwarding Database

Configuring the FDB Aging Time


You configure the aging time for dynamic FDB entries using the following command:
configure fdb agingtime <seconds>

If the aging time is set to zero, all aging entries in the database are defined as static, nonaging entries. This means the entries will not age out, but non-permanent static entries can be deleted if the switch is reset. Supported aging is between 15 and 1,000,000 seconds. The default is 5 minutes (300 seconds).

Clearing FDB Entries


You clear dynamic and permanent entries using different CLI commands. You clear dynamic FDB entries by targeting:

specified MAC addresses specified ports specified VLANs, all blackhole entries

Use the following command to clear dynamic entries from the FDB:
clear fdb {<mac_addr> | ports <port_list> | <vlan_name> | blackhole}

You clear permanent FDB entries by targeting:


all permanent entries specified MAC addresses specified VLANs all blackholed entries

Use the following command to clear permanent entries from the FDB:
delete fdbentry [all | <mac_address> [vlan <vlan name>]

Displaying FDB Entries


To display FDB entries, use the following command:
show fdb {<mac_addr> {netlogin [all | mac-based]}| permanent {netlogin [all | macbased]} | ports <port_list> {netlogin [all | mac-based]}| vlan <vlan_name> {netlogin [all | mac-based]} | stats | netlogin {all | mac-based]}}

where the following is true:


mac_addressDisplays the entry for a particular MAC address. netloginDisplays all FDBs created as a result of the netlogin process: you can display all of these

entries or just the netlogin MAC-based VLAN FDB entries.

252

ExtremeWare XOS 11.3 Concepts Guide

MAC-Based Security

NOTE
This netlogin parameter applies only for the Summit X450 switch and the BlackDiamond 8800 family of switches. See Chapter 17 for more information on netlogin

permanentDisplays all permanent entries, including the ingress and egress QoS profiles. ports <portlist>Displays the entries for a set of ports or slots and ports. vlan <vlan name>Displays the entries for a VLAN. statsDisplays the number of static, permanent, dynamic, and dropped entries; as well as the

aging time. With no options, the command displays all FDB entries. (The age parameter does not show on the display for the backup MSM on modular switches; it does show on the display for the primary MSM.)

MAC-Based Security
MAC-based security allows you to control the way the FDB is learned and populated. By managing entries in the FDB, you can block and control packet flows on a per-address basis. MAC-based security allows you to limit the number of dynamically-learned MAC addresses allowed per virtual port. You can also lock the FDB entries for a virtual port, so that the current entries will not change, and no additional addresses can be learned on the port. You can also prioritize or stop packet flows based on the source MAC address of the ingress VLAN or the destination MAC address of the egress VLAN.

NOTE
For detailed information about MAC-based security, see Chapter 16.

This section covers the following topics:


Disabling MAC Address Learning on page 253 Disabling Egress Flooding on page 254 Displaying Learning and Flooding Settings on page 256

Disabling MAC Address Learning


By default, MAC address learning is enabled on all ports. You disable learning on specified ports using the following command:
disable learning port [<port_list> | all]

If MAC address learning is disabled, only broadcast traffic, EDP traffic, and packets destined to a permanent MAC address matching that port number, are forwarded. Use this command in a secure environment where access is granted via permanent FDBs per port. Disabling learning on a port causes the MAC addresses to flood (unless you disable egress flooding) because those addresses will not be present in the FDB during a destination lookup.

ExtremeWare XOS 11.3 Concepts Guide

253

Forwarding Database

Disabling MAC Address Learning on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only.
When learning is disabled, packets with unknown source MAC addresses are dropped.

Disabling Egress Flooding


With ExtremeWare XOS software version 11.2, you can enable or disable egress flooding. Under default conditions, when the system does not find a match in the FDB for a unicast/multicast/broadcast MAC address in a packet received in a given port, the system forwards that frame to every port in the VLAN (known as Layer 2 flooding). However, you can enhance security and privacy as well as improving network performance by disabling Layer 2 egress flooding on some packets. This is particularly useful when you are working on an edge device in the network. Limiting flooded egress packets to selected interfaces is also known as upstream forwarding.

NOTE
Disabling egress flooding can affect many protocols, such as IP and ARP among others.

Figure 13 illustrates a case where you want to disable Layer 2 egress flooding on specified ports to enhance security and network performance.

Figure 13: Upstream forwarding or disabling egress flooding example


ISP FW/ Security Proxy Uplink port 3 Access Link port 1 EXOS Switch Access VLAN Access Link port 2

Client 1

Client 2
XOS004A

In this example, the three ports are in an ISP-access VLAN. Ports 1 and 2 are connected to clients 1 and 2, respectively, and port 3 is an uplink to the ISP network. Because clients 1 and 2 are in the same VLAN, client 1 could possible learn about the other clients traffic by sniffing client 2s broadcast traffic; client 1 could then possibly launch an attack on client 2. However, when you disable all egress flooding on ports 1 and 2, this sort of attack is impossible, for the following reasons:

Broadcast and multicast traffic from the clients is forwarded only to the uplink port. Any packet with unlearned destination MAC addresses is forwarded only to the uplink port. One client cannot learn any information from the other client. Because egress flooding is disabled on the access ports, the only packets forwarded to each access port are those packets that are specifically targeted for one of the ports. There is no traffic leakage.

254

ExtremeWare XOS 11.3 Concepts Guide

MAC-Based Security In this way, the communication between client 1 and client 2 is controlled. If client 1 needs to communicate with client 2 and has that IP address, client 1 sends out an ARP request to resolve the IP address for client 2.

Guidelines for Enabling or Disabling Egress Flooding


The following guidelines apply to enabling and disabling egress flooding:

Egress flooding can be disabled on ports that are in a load-sharing group. If that is the situation, the ports in the group take on the egress flooding state of the master port; each member port of the loadsharing group has the same state as the master port. FDB learning is independent of egress flooding; either can be enabled or disabled independently. Disabling unicast (or all) egress flooding to a port also stops packets with unknown MAC addresses to be flooded to that port. Disabling broadcast (or all) egress flooding to a port also stops broadcast packets to be flooded to that port.

Disabling Egress Flooding on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
You can enable or disable egress flooding for unicast, multicast, or broadcast MAC addresses, as well as for all packets on the ports of the BlackDiamond 8800 family of switches (formerly known as Aspen) or the Summit X450 switch. Disabling multicasting egress flooding does not affect those packets within an IGMP membership group at all; those packets are still forwarded out. If IGMP snooping is disabled, multicast packets with static FDB entries are forwarded according to the FDB entry. You enable egress flooding for these switches using the following command:
enable flooding [all_cast | broadcast | multicast | unicast] port [<port_list> | all]

To disable flooding for these switches, use the following command:


disable flooding [all_cast | broadcast | multicast | unicast] port [<port_list> | all]

Disabling Egress Flooding on the BlackDiamond 10K Switch Only


You must enable or disable egress flooding on all packets on the specified port or ports. You cannot specify broadcast, unicast, or multicast packets; the egress flooding command applies to all packets. Disabling multicasting egress flooding does not affect those packets within an IGMP membership group at all; those packets are still forwarded out. If IGMP snooping is disabled, multicast packets are not flooded. Issue the following command to enable egress flooding on the BlackDiamond 10K switch:
enable flooding all_cast port [<port_list> | all]

To disable egress flooding on the BlackDiamond 10K switch, issue this command:
disable flooding all_cast port [<port_list> | all]

ExtremeWare XOS 11.3 Concepts Guide

255

Forwarding Database

NOTE
When you disable egress flooding on the BlackDiamond 10K switch, you also turn off broadcasting.

Displaying Learning and Flooding Settings


To display the status of MAC learning and egress flooding, use the following command: show ports {mgmt | <port_list>} information {detail} Following is sample output from this command:
QB_Mariner.4 > show port 3:1 info Port Diag Flags Link Link Num Num Num Jumbo QOS Load State UPS STP VLAN Proto Size profile Master ================================================================================ 3:1 P Em------e-- ready 0 0 1 1 9216 ================================================================================ Flags : a - Load Sharing Algorithm address-based, D - Port Disabled, e - Extreme Discovery Protocol Enabled, E - Port Enabled, f - Flooding Enabled, g - Egress TOS Enabled, j - Jumbo Frame Enabled, l - Load Sharing Enabled, m - MACLearning Enabled, n - Ingress TOS Enabled, o - Dot1p Replacement Enabled, P - Software redundant port(Primary), q - Background QOS Monitoring Enabled, R - Software redundant port(Redunda nt), s - diffserv Replacement Enabled, v - Vman Enabled, f - Unicast Flooding Enabled M - Multicast Flooding Enabled, B - Broadcast Flooding Enabled

NOTE
The BlackDiamond 10K switch has an additional flag: p - Load Sharing Algorithm, port-based.

Multicast FDB with Multiport EntrySummit X450 Switch and BlackDiamond 8800 Chassis Only
Beginning with ExtremeWare XOS version 11.3 on the BlackDiamond 8800 family of switches and the Summit X450 switch, you can create FDB entries to multicast MAC addresses (that is, 01:00:00:00:00:01) and list one or more ports. Use the create fdbentry vlan ports command to enter the multicast FDB address. Once traffic with a multicast MAC destination address enters the switch, that traffic is multicast to all ports on the list. However, if the MAC address is in the IP multicast range (for example, 01:00:5e:XX:XX:XX), IGMP snooping rules take precedence over the multicast static FDB entry. Of course, if you disable IGMP snooping on all VLANs, the static FDB entry forwards traffic.

256

ExtremeWare XOS 11.3 Concepts Guide

12 Policy Manager
This chapter describes the following topics:

Policy Manager on page 257 Creating and Editing Policies on page 257 Checking Policies on page 258 Refreshing Policies on page 259 Applying Policies on page 259

Policy Manager
One of the processes that make up the ExtremeWare XOS system is the policy manager. The policy manager is responsible for maintaining a set of policy statements in a policy database and communicating these policy statements to the applications that request them. Policies are used by the routing protocol applications to control the advertisement, reception, and use of routing information by the switch. Using policies, a set of routes can be selectively permitted (or denied) based on their attributes, for advertisements in the routing domain. The routing protocol application can also modify the attributes of the routing information, based on the policy statements. Policies are also used by the access control list (ACL) application to perform packet filtering and forwarding decisions on packets. The ACL application will program these policies into the packet filtering hardware on the switch. Packets can be dropped, forwarded, moved to a different QoS profile, or counted, based on the policy statements provided by the policy manager.

Creating and Editing Policies


A policy is created by writing a text file that contains a series of rule entries describing match conditions and actions to take. Prior to release 11.0, all policies were created by writing a text file on a separate machine and then downloading it to the switch. Once on the switch, the file was then loaded into a policy database to be used by applications on the switch. With release 11.0, policy text files can also be created and edited directly on the switch. NOTE
Although ExtremeWare XOS does not prohibit mixing ACL and routing type entries in a policy file, it is strongly recommended that you do not mix the entries, and you use separate policy files for ACL and routing policies.

When you create a policy file, name the file with the policy name that you will use when applying the policy, and use .pol as the filename extension. For example, the policy name boundary refers to the text file boundary.pol.

ExtremeWare XOS 11.3 Concepts Guide

257

Policy Manager

Using the Edit Command


A VI-like editor is available on the switch to edit policies. To edit a policy file on the switch by launching the editor, use the following command:
edit policy <filename>

There are many commands available with the editor. For information about the editor commands, use any tutorial or documentation about VI. The following is only a short introduction to the editor. Edit operates in one of two modes; command and input. When a file first opens, you are in the command mode. To write in the file, use the keyboard arrow keys to position your cursor within the file, then press one of the following keys to enter input mode:

i - To insert text ahead of the initial cursor position a- To append text after the initial cursor position

To escape the input mode and return to the command mode, press the Escape key. There are several commands that can be used from the command mode. The following are the most commonly used:

dd - To delete the current line yy - To copy the current line p - To paste the line copied :w - To write (save) the file :q - To quit the file if no changes were made :q! - To forcefully quit the file without saving changes :wq - To write and quit the file

Using a Separate Machine


You can also edit policies on a separate machine. Any common text editor can be used to create a policy file. The file is then transferred to the switch using TFTP and then applied. To transfer policy files to the switch, use the following command:
tftp [<host_name> | <ip_address>] {-v <vr_name>} [-g | -p] [{-l [<local_file> | memorycard <local-file-memcard>]} {-r <remote_file>} | {-r <remote_file>} {-l [<local_file> | memorycard <local-file-memcard]}]

Checking Policies
A policy file can be checked to see if it is syntactically correct. Use the following command to check the policy syntax:
check policy <policy-name>

This command can only determine if the syntax of the policy file is correct and can be loaded into the policy manager database. Since a policy can be used by multiple applications, a particular application may have additional constraints on allowable policies.

258

ExtremeWare XOS 11.3 Concepts Guide

Applying Policies

Refreshing Policies
When a policy file is changed (such as adding, deleting an entry, adding/deleting/modifying a statement), the information in the policy database does not change until the policy is refreshed. The user must refresh the policy so that the latest copy of policy is used. When the policy is refreshed, the new policy file is read, processed, and stored in the server database. Any clients that use the policy are updated. Use the following command to refresh the policy:
refresh policy <policy-name>

For ACL policies only, during the time that an ACL policy is refreshed, packets on the interface are blackholed, by default. This is to protect the switch during the short time that the policy is being applied to the hardware. It is conceivable that an unwanted packet could be forwarded by the switch as the new ACL is being setup in the hardware. You can disable this behavior. To control the behavior of the switch during an ACL refresh, use the following commands:
enable access-list refresh blackhole disable access-list refresh blackhole

Applying Policies
ACL policies and routing policies are applied using different commands.

Applying ACL Policies


A policy intended to be used as an ACL is applied to an interface, and the CLI command option is named <aclname>. Supply the policy name in place of the <aclname> option. To apply an ACL policy, use the following command:
configure access-list <aclname> [any | ports <portlist> | vlan <vlanname>] {ingress | egress}

If you use the any keyword, the ACL is applied to all the interfaces and is referred to as the wildcard ACL. This ACL is evaluated for any ports without specific ACLs, and it is also applied to any packets that do not match the specific ACLs applied to the interfaces. If an ACL is already configured on an interface, the command will be rejected and an error message displayed. To remove an ACL from an interface, use the following command:
unconfigure access-list {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

To display which interfaces have ACLs configured, and which ACL is on which interface, use the following command:
show access-list {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

ExtremeWare XOS 11.3 Concepts Guide

259

Policy Manager

Applying Routing Policies


To apply a routing policy, use the command appropriate to the client. Different protocols support different ways to apply policies, but there are some generalities. Policies applied with commands that use the keyword import-policy control the routes imported to the protocol from the switch routing table. The following are examples for the BGP and RIP protocols:
configure bgp import-policy [<policy-name> | none] configure rip import-policy [<policy-name> | none]

Commands that use the keyword route-policy control the routes advertised or received by the protocol. For BGP and RIP, here are some examples:
configure bgp neighbor [<remoteaddr> | all] {address-family [ipv4-unicast | ipv4multicast]} route-policy [in | out] [none | <policy>] configure bgp peer-group <peer-group-name> route-policy [in | out] [none | <policy>] configure rip vlan [<vlan-name> | all] route-policy [in | out] [<policy-name> | none]

Other examples of commands that use route policies include:


configure ospf area <area-identifier> external-filter [<policy-map> |none] configure ospf area <area-identifier> interarea-filter [<policy-map> | none] configure rip vlan [<vlan-name> | all] trusted-gateway [<policy-name> | none]

To remove a routing policy, use the none option in the command.

260

ExtremeWare XOS 11.3 Concepts Guide

13 Access Lists (ACLs)


This chapter describes the following topics:

ACLs on page 261 ACL Policy File Syntax on page 262 Dynamic ACLs on page 268 ACL Evaluation Precedence on page 269 ACL MeteringBlackDiamond 8800 Family and Summit X450 Only on page 271 Applying ACL Policy Files on page 272 Displaying and Clearing ACL Counters on page 273 Example ACL Rule Entries on page 273

ACLs
ACLs are used to perform packet filtering and forwarding decisions on traffic traversing the switch. Each packet arriving on an ingress port and/or VLAN is compared to the access list applied to that interface and is either permitted or denied. On the BlackDiamond 10K switch, packets egressing an interface can also be filtered, however, only a subset of the filtering conditions available for ingress filtering are available for egress filtering. In addition to forwarding or dropping packets that match an ACL, the switch can also perform additional operations like incrementing counters, logging packet headers, mirroring traffic to a monitor port, sending the packet to a QoS profile, and, for the BlackDiamond 8800 family and Summit X450 switches only, meter the packets to control bandwidth. Using ACLs has no impact on switch performance (with the minor exception of the mirror-cpu action modifier). ACLs are typically applied to traffic that crosses Layer 3 router boundaries, but it is possible to use access lists within a Layer 2 virtual LAN (VLAN). ACLs in ExtremeWare XOS apply to all traffic. This is somewhat different from the behavior in ExtremeWare. For example, if you deny all the traffic to a port, no traffic, including control packets, such as OSPF or RIP, will reach the switch and the adjacency will be dropped. You must explicitly allow those type of packets (if desired). In ExtremeWare, an ACL that denied all traffic would allow control packets (those bound for the CPU) to reach the switch. ACLs are often referred to as access lists. ACLs are created in two different ways. One method is to create an ACL policy file and apply that ACL policy file to a list of ports, a VLAN, or to all interfaces. This first method creates ACLs that can be persistent across switch reboots, can contain a large number of rule entries, and are all applied at the same time. See ACL Policy File Syntax on page 262 for information about creating ACLs using policy files. For information about creating policy files, see Chapter 12, Policy Manager. The second method to create an ACL is to use the CLI to specify a single rule, called a dynamic ACL. Dynamic ACLs do not persist across a reboot and consist of only a single rule. Multiple dynamic ACLs

ExtremeWare XOS 11.3 Concepts Guide

261

Access Lists (ACLs) can be applied to an interface, and the precedence of the ACLs is determined as they are being configured. See Dynamic ACLs on page 268 for information about creating dynamic ACLs.

ACL Policy File Syntax


An ACL policy file contains one or more rule entries. Each rule entry consists of:

a rule entry name, unique within the same ACL. zero or more match conditions. zero or one action (permit or deny). If no action is specified, the packet is permitted by default. zero or more action modifiers.

Each rule entry in the file uses the following syntax:


entry <ACLrulename>{ if { <match-conditions>; } then { <action>; <action-modifiers>; } }

Here is an example of a rule entry:


entry udpacl { if { source-address 10.203.134.0/24; destination-address 140.158.18.16/32; protocol udp; source-port 190; destination-port 1200 - 1250; } then { permit; } }

ACL rule entries are evaluated in order, from the beginning of the file to the end, as follows:

If the packet matches all the match conditions, the action in the then statement is taken and the evaluation process terminates. For ingress ACLs, if a rule entry does not contain any match condition, the packet is considered to match and the action in the rule entrys then statement is taken and the evaluation process terminates. For egress ACLs, if a rule entry does not contain any match condition, no packets will match. See the section, Matching All Egress Packets for more information. If the packet matches all the match conditions, and if there is no action specified in the then statement, the action permit is taken by default. If the packet does not match all the match conditions, the next rule entry in the ACL is evaluated. This process continues until either the packet matches all the match conditions in one of the subsequent rule entries or there are no more entries. If a packet passes through all the rule entries in the ACL without matching any of them, it is permitted.

262

ExtremeWare XOS 11.3 Concepts Guide

ACLs Often an ACL will have a rule entry at the end of the ACL with no match conditions. This entry will match any ingress packets not otherwise processed, so that user can specify an action to overwrite the default permit action. Matching All Egress Packets. Unlike ingress ACLs, for egress ACLs, you must specify either a source or destination address, instead of writing a rule with no match conditions. For example, an ingress ACL deny all rule could be:
entry DenyAllIngress{ if { } then { deny; } }

The previous rule would not work as an egress ACL. The following is an example of an egress ACL deny all rule:
entry DenyAllEgress{ if { source-address 0.0.0.0/0; } then { deny; } }

Rule EvaluationBlackDiamond 8800 Family and Summit X450 Only


On the BlackDiamond 8800 family and Summit X450, all matching rule actions in a policy are applied to a given packet. Conflicting actions (deny vs. permit, etc) are resolved by the relative matching rule order in the policy file. This means that multiple counters can be incremented for a single packet.

Match Conditions
You can specify multiple, single, or zero match conditions. If no match condition is specified, all packets match the rule entry. Among the match conditions commonly used are:

IP source address and mask IP destination address and mask TCP or UDP source port range TCP or UDP destination port range

Table 34 describes all the possible match conditions.

Actions
The actions are:

permitthe packet is forwarded denythe packet is dropped

The default action is permit, so if no action is specified in a rule entry, the packet is forwarded.

ExtremeWare XOS 11.3 Concepts Guide

263

Access Lists (ACLs)

Action Modifiers
Additional actions can also be specified, independent of whether the packet is dropped or forwarded. These additional actions are called action modifiers. Not all action modifiers are available on all switches, and not all are available for both ingress and egress ACLs. The action modifiers are:

count <countername>increments the counter named in the action modifier (ingress only) loglogs the packet header log-rawlogs the packet header in hex format meter <metername>takes action depending on the traffic rate (BlackDiamond 8800 family and

Summit X450 switches only)


mirrorsends a copy of the packet to the monitor (mirror) port (ingress only) mirror-cpumirrors a copy of the packet to the CPU in order to log it qosprofile <qosprofilename>forwards the packet to the specified QoS profile (ingress only) redirect <ipv4 addr>forwards the packet to the specified IPv4 address (BlackDiamond 10K

only)

replace-dscpreplace the packets DSCP field with the value from the associated QoS profile (BlackDiamond 10K ingress only) replace-dot1preplace the packets 802.1p field with the value from the associated QoS profile (BlackDiamond 10K ingress only)

To count packets: When the ACL entry match conditions are met, the specified counter is incremented. The counter value can be displayed by the command:
show access-list counter {<countername>} {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

To log packets: Packets are logged only when they go to the CPU, so packets in the fastpath are not automatically logged. You must use both the mirror-cpu action modifier and the log or log-raw action modifier if you want to log both slowpath and fastpath packets that match the ACL rule entry. Additionally, KERN:INFO messages are not logged by default. You must configure the EMS target to log these messages. See Chapter 8, Status Monitoring and Statistics, for information about configuring EMS. To meter packets: BlackDiamond 8800 Family and Summit X450 OnlyFor the BlackDiamond 8800 family and Summit X450 switches, the meter <metername> action modifier associates a rule entry with an ACL meter. See the section, ACL MeteringBlackDiamond 8800 Family and Summit X450 Only on page 271 for more information. To mirror packets: You must enable port-mirroring on your switch. See the section, Switch Port Mirroring on page 130. If you attempt to apply a policy that requires port-mirroring, you will receive an error message if port-mirroring is not enabled. To redirect packets: BlackDiamond 10K OnlyPackets are forwarded to the IPv4 address specified, without modifying the IP header. The IPv4 address must be in the IP ARP cache, otherwise the packet is forwarded normally. Only fast path traffic can be redirected. You may want to create a static ARP entry for the redirection IP address, so that there will always be a cache entry. To replace DSCP or 802.1p fields: BlackDiamond 10K Ingress OnlySpecify a QoS profile for matching packets. The field values are replaced with the value associated with that profile. In the following

264

ExtremeWare XOS 11.3 Concepts Guide

ACLs example, DiffServ replacement is configured such that QP8 is mapped to code point 56. Matching packets are sent to QP8, and the DSCP value in the packet is set to 56:
entry voice_entry { if { source-address 2.2.2.2/32; } then { qosprofile qp8; replace-dscp; } }

See Chapter 15, Quality of Service, for more details about QoS profiles, and 802.1p and DSCP replacement.

Syntax Details
Table 34 lists the match conditions that can be used with ACLs, and whether the condition can be used for ingress ACLs only, or with both ingress and egress. The conditions are case-insensitive; for example, the match condition listed in the table as TCP-flags can also be written as tcp-flags. Within Table 34 are five different data types used in matching packets. Table 35 lists the data types and details on using them.

Table 34: ACL match conditions


Applicable IP Protocols/ Direction Ethernet/ Ingress only

Match Conditions ethernet-type <number>

Description Ethernet packet type. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): ETHER-P-IP (0x0800), ETHER-P-8021Q (0x8100), ETHER-P-IPV6 (0x86DD) Ethernet source MAC address Ethernet destination MAC address IP source address and mask. Egress ACLs do not support IPv6 addresses, only IPv4 addresses. Use either all IPv4 or all IPv6 addresses in an ACL.1 IP destination address and mask. Egress ACLs do not support IPv6 addresses, only IPv4 addresses. Use either all IPv4 or all IPv6 addresses in an ACL.1 IP protocol field. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): egp(8), esp(5), gre(47), icmp(1), igmp(2), ipip(4), ipv6(41), ospf(89), pim(102), rsvp(46), tcp(6), or udp(17) BlackDiamond 10K onlyIP fragmented packet. FO > 0 (FO = Fragment Offset in IP header) Non-IP fragmented packet or first fragmented packet. FO==0. TCP or UDP source port. In place of the numeric value, you can specify one of the text synonyms listed under destination port.

ethernet-source-address <mac-address> ethernet-destination-address <mac-address> source-address <prefix>

Ethernet/ Ingress only Ethernet/ Ingress only All IP/ Ingress and Egress All IP/ Ingress and Egress All IP/ Ingress and Egress All IP, no L4 rules/Ingress only All IP/ Ingress only TCP, UDP/ Ingress and Egress

destination-address <prefix>

protocol <number>

fragments

first-fragments Source-port {<number> | <range>}

ExtremeWare XOS 11.3 Concepts Guide

265

Access Lists (ACLs)

Table 34: ACL match conditions (Continued)


Applicable IP Protocols/ Direction TCP, UDP/ Ingress and Egress

Match Conditions Destination-port {<number> | <range>}

Description TCP or UDP destination port. Normally, you specify this match in conjunction with the protocol match to determine which protocol is being used on the port. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): afs(1483), bgp(179), biff(512), bootpc(68), bootps(67), cmd(514), cvspserver(2401), DHCP(67), domain(53), eklogin(2105), ekshell(2106), exec(512), finger(79), ftp(21), ftp-data(20), http(80), https(443), ident(113), imap(143), kerberos-sec(88), klogin(543), kpasswd(761), krb-prop(754), krbupdate(760), kshell(544), idap(389), login(513), mobileip-agent(434), mobileip-mn(435), msdp(639), netbios-dgm(138), netbiosns(137), netbios-ssn(139), nfsd(2049), nntp(119), ntalk(518), ntp(123), pop3(110), pptp(1723), printer(515), radacct(1813), radius(1812), rip(520), rkinit(2108), smtp(25), snmp(161), snmptrap(162), snpp(444), socks(1080), ssh(22), sunrpc(111), syslog(514), tacacs-ds(65), talk(517), telnet(23), tftp(69), timed(525), who(513), xdmcp(177), zephyr-clt(2103), or zephyr-hm(2104). TCP flags. Normally, you specify this match in conjunction with the protocol match statement. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): ACK(0x10), FIN(0x01), PUSH(0x08), RST(0x04), SYN(0x02), URG(0x20), SYN_ACK(0x12). IGMP message type. Possible values and text synonyms: v1report(0x12), v2-report(0x16), v3-report(0x22), V2-leave (0x17), or query(0x11) ICMP type field. Normally, you specify this match in conjunction with the protocol match statement. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): echo-reply(0), echorequest(8), info-reply(16), info-request(15), mask-request(17), mask-reply(18), parameter-problem(12), redirect(5), routeradvertisement(9), router-solicit(10), source-quench(4), timeexceeded(11), timestamp(13), timestamp-reply(14), or unreachable(3).

TCP-flags <bitfield>

TCP/Ingress and Egress

IGMP-msg-type <number>

IGMP/ Ingress and Egress ICMP/Ingress and Egress

ICMP-type <number>

266

ExtremeWare XOS 11.3 Concepts Guide

ACLs

Table 34: ACL match conditions (Continued)


Applicable IP Protocols/ Direction ICMP/Ingress and Egress

Match Conditions ICMP-code <number>

Description ICMP code field. This value or keyword provides more specific information than the icmp-type. Because the value's meaning depends upon the associated icmp-type, you must specify the icmp-type along with the icmp-code. In place of the numeric value, you can specify one of the following text synonyms (the field values also listed); the keywords are grouped by the ICMP type with which they are associated: Parameter-problem: ip-header-bad(0), required-option-missing(1) Redirect: redirect-for-host (1), redirect-for-network (2), redirect-for-tosand-host (3), redirect-for-tos-and-net (2) Time-exceeded: ttl-eq-zero-during-reassembly(1), ttl-eq-zero-during-transit(0) Unreachable: communication-prohibited-by-filtering(13), destination-hostprohibited(10), destination-host-unknown(7), destinationnetwork-prohibited(9), destination-network-unknown(6), fragmentation-needed(4), host-precedence-violation(14), hostunreachable(1), host-unreachable-for-TOS(12), networkunreachable(0), network-unreachable-for-TOS(11), portunreachable(3), precedence-cutoff-in-effect(15), protocolunreachable(2), source-host-isolated(8), source-route-failed(5)

IP-TOS <number> (BlackDiamond 10K Only)

IP TOS field. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): minimize-delay 16 (0x10), maximize-reliability 4(0x04), minimize-cost2 (0x02), and normal-service 0(0x00) Differentiated Service Code Point. The DiffServ protocol uses the type of service (TOS) byte in the IP header, and the most significant six bits of this type form the DSCP. In place of the numeric value, you can specify one of the following text synonyms (the field values are also listed): The Expedited Forwarding RFC defines one code point: ef(46) The Assured Forwarding RFC defines 4 classes, with 3 drop precedences in each class, for a total of 12 code points: af11(10), af12(12), af13(14), af21(18), af22(20), af23(22), af31(26), af32(28),af33(30), af41(34), af42(36), af43(38)

All IP/ Ingress and Egress All IP/ Ingress only

DSCP <number> (BlackDiamond 10K Only)

1. You can not specify an IPv6 address with a 128-bit mask (host entry) for the Summit X450.

NOTE
Directed ARP response packets cannot be blocked with ACLs from reaching the CPU and being learned on the BlackDiamond 8800 family and Summit X450 switches.

Along with the data types described in Table 35, you can use the operators <, <=, >, and >= to specify match conditions. For example, the match condition, source-port > 190, will match packets with a source port greater than 190. Be sure to use a space before and after an operator.

ExtremeWare XOS 11.3 Concepts Guide

267

Access Lists (ACLs)

NOTE
The BlackDiamond 8800 family and Summit X450 support 128 rules per Gigabit Ethernet port and 1024 rules per 10 Gigabit Ethernet port. Certain features also use rules for their implementation. A single match condition can require the creation of many rules, and may not be supported on these switches. For example, the match condition source-port 1000 - 3000 requires creating 2000 rules, and is not supported on these switches. The match condition source-port > 90 will also not work, as it requires a large number of rules to implement in the hardware. The match condition source-port 100 - 200 could work, as it uses fewer than 120 rules to implement. See also the section, Conserving ACL Masks (BlackDiamond 8800 family and Summit X450 switches only), for further information on ACL limits.

Table 35: ACL match condition data types


Condition Data Type prefix Description IP source and destination address prefixes. To specify the address prefix, use the notation prefix/prefix-length. For a host address, prefix-length should be set to 32. Numeric value, such as TCP or UDP source and destination port number, IP protocol number. A range of numeric values. To specify the numeric range, use the notation: number number Used to match specific bits in an IP packet, such as TCP flags and the fragment flag. 6-byte hardware address.

number range bit-field mac-address

IPv6 ACL Address MasksBlackDiamond 10K Only


The BlackDiamond 10K uses address masks for matching the 128-bit IPv6 addresses in ACLs. The default mask is 0:ffff:ffff:ffff:0:ffff:ffff:ffff, so for purposes of ACL matching the BlackDiamond 10K ignores the bits 1 through 16 and 65 through 80 (counting the highest-order bit as bit 1). There is a separate mask for the IPv6 source and IPv6 destination address. You can change the masks used for ACL matching, but the change will not take effect until you reboot the switch. Use the following command to configure the IPv6 ACL masks:
configure ipv6acl address-mask [destination <ipv6_address> | source <ipv6_address>]

Dynamic ACLs
Dynamic ACLs are created using the CLI. They use a similar syntax and can accomplish the same actions as single rule entries used in ACL policy files. More than one dynamic ACL can be applied to an interface, and the precedence among the dynamic ACLs is determined as they are being configured. Dynamic ACLs have a higher precedence than ACLs applied using a policy file. There are two steps to using a dynamic ACL on an interface: 1 Create the dynamic ACL rule 2 Configure the ACL rule on the interface

Creating the Dynamic ACL Rule


Creating a dynamic ACL rule is similar to creating an ACL policy file rule entry. You will specify the name of the dynamic ACL rule, the match conditions, and the actions and action-modifiers. The match

268

ExtremeWare XOS 11.3 Concepts Guide

ACLs conditions, actions, and action-modifiers are the same as those that are available for ACL policy files (see ACL Policy File Syntax on page 262). In contrast to the ACL policy file entries, dynamic ACLs are created directly in the CLI. Use the following command to create a dynamic ACL:
create access-list <dynamic-rule> <conditions> <actions>

As an example of creating a dynamic ACL rule, lets compare an ACL policy file entry with the CLI command that creates the equivalent dynamic ACL rule. The following ACL policy file entry will drop all ICMP echo-requests:
entry icmp-echo { if { protocol icmp; icmp-type echo-request; } then { deny; } }

To create the equivalent dynamic ACL rule, use the following command:
create access-list icmp-echo protocol icmp;icmp-type echo-request deny

Notice that the conditions parameter is a quoted string that corresponds to the match conditions in the if { ... } portion of the ACL policy file entry. The individual match conditions are concatenated into a single string. The actions parameter corresponds to the then { ... } portion of the ACL policy file entry. From the command line, you can get a list of match conditions and actions by using the following command:
check policy attribute {<attr>}

Limitations. Dynamic ACL rule names must be unique, but can be the same as used in a policy-file based ACL. Any dynamic rule counter names must be unique. Dynamic ACLs only apply to ACLs and do not apply to CLEAR-Flow rules.

Configuring the ACL Rule on the Interface


Once a dynamic ACL rule has been created, it can be applied to a port, VLAN, or to the wildcard any interface. When the ACL is applied, you will specify the precedence of the rule among the dynamic ACL rules. Use the following command to configure the dynamic ACL rule on an interface:
configure access-list add <dynamic_rule> [after <rule> | before <rule> | first | last][any | ports <portlist> | vlan <vlanname>] {ingress | egress}

To remove a dynamic ACL from an interface, use the following command:


configure access-list delete <ruleName> [all | any | ports <portlist> | vlan <vlanname>] {ingress | egress}

ACL Evaluation Precedence


This section discusses the precedence for evaluation among ACL rules.

ExtremeWare XOS 11.3 Concepts Guide

269

Access Lists (ACLs)

Precedence of Dynamic ACLs


Dynamic ACLs have a higher precedence than any ACLs applied using policy files. The precedence among any dynamic ACLs is determined as they are configured.

Precedence within an ACL


An ACL is a policy file that contains one or more rules. In ExtremeWare XOS, each rule can be one of following types:

L2 rulea rule containing only Layer 2 (L2) matching conditions, such as Ethernet MAC address and Ethernet type. L3 rulea rule containing only Layer 3 (L3) matching conditions, such as source or destination IP address and protocol. L4 rulea rule containing both Layer 3 (L3) and Layer 4 (L4) matching conditions, such as TCP/ UDP port number. NOTE

BlackDiamond 10K switch onlyL2 matching conditions cannot be mixed with L3/L4 matching conditions in a rule, otherwise, syntax checking will fail.

BlackDiamond 10K Only. When an ACL file contains both L2 and L3/L4 rules:

L3/L4 rules have higher precedence over L2 rules. L3/L4 rules are evaluated before any L2 rules. The precedence among L3/L4 rules is determined by their relative position in the ACL file. Rules are evaluated sequentially from top to bottom. The precedence among L2 rules is determined by their position in the ACL file. Rules are evaluated sequentially from top to bottom. It is recommended that L2 and L3/L4 rules be grouped together for easy debugging.

BlackDiamond 8800 family and Summit X450 Only. Rule precedence is solely determined by the rules relative order in the policy file. L2, L3, and L4 rules are evaluated in the order found in the file.

Precedence among interface types


As an example of precedence among interface types, suppose a physical port 1:2 is member port of a VLAN yellow. The ACL evaluation is performed in the following sequence:

If the ACL is configured on port 1:2, the port-based ACL is evaluated and the evaluation process terminates. If the ACL is configured on the VLAN yellow, the VLAN-based ACL is evaluated and the evaluation process terminates. If the wildcard ACL is configured, the wildcard ACL is evaluated and evaluation process terminates.

In summary, the port-based ACL has highest precedence, followed by the VLAN-based ACL and then the wildcard ACL.

270

ExtremeWare XOS 11.3 Concepts Guide

ACLs

Fragmented packet handling


Two keywords are used to support fragmentation in ACLs:

fragmentsFO field > 0 (FO means the fragment offset field in the IP header.)BlackDiamond 10K only. first-fragmentsFO == 0.

Policy file syntax checker. The fragments keyword cannot be used in a rule with L4 information. The syntax checker will reject such policy files.

Packet processing flow


The following rules are used to evaluate fragmented packets or rules that use the fragments or firstfragments keywords.

With no keyword specified, processing proceeds as follows:

An L3-only rule that does not contain either the fragments or first-fragments keyword matches any IP packets. An L4 rule that does not contain either the fragments or first-fragments keyword matches nonfragmented or initial-fragment packets.

With the fragment keyword specified (BlackDiamond 10K only):


An L3-only rule with the fragments keyword only matches fragmented packets. An L4 rule with the fragments keyword is not valid (see above).

With the first-fragments keyword specified:

An L3-only rule with the first-fragments keyword matches non-fragmented or initial fragment packets. An L4 rule with the first-fragments keyword matches non-fragmented or initial fragment packets.

ACL MeteringBlackDiamond 8800 Family and Summit X450 Only


The BlackDiamond 8800 family and Summit X450 switches provide a metering capability which can be used to associate an ACL rule to a specified bit-rate and out-of-profile action. The rate granularity is 64kbps (up to 1Gbps for GE ports and up to 10Gbps for 10G ports) and the out-of-profile actions are drop, set the drop precedence, or mark the DSCP with a configured value. Additionally, each meter has an associated out-of-profile byte counter which counts the number of packets that were above the committed-rate (and subject to the out-of-profile-action). To configure ACL metering, you will do the following steps: 1 Create the meter 2 Configure the meter 3 Associate the meter with an ACL rule entry

Creating the ACL Meter


To create the ACL meter, use the following command:

ExtremeWare XOS 11.3 Concepts Guide

271

Access Lists (ACLs)


create meter <metername>

To delete the meter, use the following command:


delete meter <metername>

Configuring the ACL Meter


After the ACL meter is created, you will configure it. Configuring the ACL meter sets allowable traffic limits, and the actions to take with out of limit traffic. Use the following command to configure an ACL meter:
configure meter <metername> {max-burst-size <burst-size> [Gb | Kb | Mb]} {committedrate <cir-rate> [Gbps | Mbps | Kbps]} {out-actions [drop | set-drop-precedence {dscp [none | <dscp-value>]}}

Associating the Meter with an ACL


To associate a meter with an ACL, you will add the meter <metername> statement to the action modifier of the ACL rule entry, similar to the count <countername> statement. For example, to associate the meter maximum_bandwidth with an ACL, use syntax similar to the following:
entry meter_bw { if { } then { meter maximum_bandwidth; } }

This example will take the actions specified for the meter maximum_bandwidth for all the traffic that this ACL is applied to.

Applying ACL Policy Files


A policy file intended to be used as an ACL is applied to a port, VLAN, or to all interfaces (the any keyword). Use the name of the policy file for the <aclname> parameter in the CLI command. To apply an ACL policy, use the following command:
configure access-list <aclname> [any | ports <portlist> | vlan <vlanname>] {ingress | egress}

If you use the any keyword, the ACL is applied to all the interfaces and is referred to as the wildcard ACL. This ACL is evaluated for any ports without specific ACLs, and it is also applied to any packets that do not match the specific ACLs applied to the interfaces. If an ACL is already configured on an interface, the command will be rejected and an error message displayed. To remove an ACL from an interface, use the following command:
unconfigure access-list {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

272

ExtremeWare XOS 11.3 Concepts Guide

Applying ACL Policy Files To display which interfaces have ACLs configured, and which ACL is on which interface, use the following command:
show access-list {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

Displaying and Clearing ACL Counters


To display the ACL counters, use the following command:
show access-list counter {<countername>} {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

To clear the access list counters, use the following command:


clear access-list {dynamic} counter {<countername>} {any | ports <portlist> | vlan <vlanname>} {ingress | egress}

Example ACL Rule Entries


The following entry accepts all the UDP packets from the 10.203.134.0/24 subnet that are destined for the host 140.158.18.16, with source port 190 and a destination port in the range of 1200 to 1250:
entry udpacl { if { source-address 10.203.134.0/24; destination-address 140.158.18.16/32; protocol udp; source-port 190; destination-port 1200 - 1250; } then { permit; } }

The following rule entry accepts TCP packets from the 10.203.134.0/24 subnet with a source port larger than 190 and ACK & SYN bits set and also increments the counter tcpcnt. The packets will be forwarded using QoS profile QP3. This example will only work with the BlackDiamond 10K, since the match condition source-port > 190 alone will create more than 118 rules in the hardware:
entry tcpacl { if { source-address 10.203.134.0/24; protocol TCP; source-port > 190; tcp-flags syn_ack; } then { permit; count tcpcnt ; qosprofile qp3; } }

The following example denies ICMP echo request (ping) packets originating from the 10.203.134.0/24 subnet, and increments the counter icmpcnt:

ExtremeWare XOS 11.3 Concepts Guide

273

Access Lists (ACLs)


entry icmp { if { source-address 10.203.134.0/24; protocol icmp; icmp-type echo-request; } then { deny; count icmpcnt; } }

The following example prevents TCP connections from being established from the 10.10.20.0/24 subnet, but allows established connections to continue, and allows TCP connections to be established to that subnet. A TCP connection is established by sending a TCP packet with the SYN flag set, so this example blocks TCP SYN packets. This example emulates the behavior of the ExtremeWare permit-established ACL command:
entry permit-established { if { source-address 10.10.20.0/24; protocol TCP; tcp-flags syn; } then { deny; } }

The following entry denies every packet and increments the counter default:
entry default { if { } then { deny; count default; } }

The following entry denies IPv6 packets from source addresses in the 2001:db8:c0a8::/48 subnets and to destination addresses in the 2001:db8:c0a0:1234::/64 subnets:
entry ipv6entry { if { source-address 2001:DB8:C0A8:: / 48; destination-address 2001:DB8:C0A0:1234:: / 64; } then { deny; } }

Conserving ACL Masks (BlackDiamond 8800 family and Summit X450 switches only)
The BlackDiamond 8800 family and Summit X450 switches have a total of sixteen ACL masks per port on the switch. To avoid exhausting the masks available on the switch, you must carefully plan your use of ACL masks.

274

ExtremeWare XOS 11.3 Concepts Guide

Applying ACL Policy Files An ACL mask defines a unique match criteria and relative rule precedence. Masks are automatically generated based on the contents of an access-list policy. Only adjacent rules within the policy that have identical match criteria will utilize the same ACL mask. For this reason, it is advantageous to list all rules with the same match criteria together unless relative precedence with other policy rules is required. Using VLAN-based or wildcards ACLs requires that the ACL masks are allocated on every port in the system. For example, consider the following 2 policies:
policy1.pol : entry one { if { source-address 1.1.1.1/32; } then { count debug; } } entry two { if { protocol tcp; destination-port 23; } then { permit; } } entry three { if { source-address 2.2.2.2/32; } then { deny; } } policy2.pol : entry one { if { source-address 1.1.1.1/32; } then { count debug; } } entry three { if { source-address 2.2.2.2/32; } then { deny; } } entry two { if { protocol tcp; destination-port 23; } then { permit; } }

ExtremeWare XOS 11.3 Concepts Guide

275

Access Lists (ACLs) In this example, the only difference between policy1.pol and policy2.pol is that rule entries two and three are swapped. Policy1.pol consumes three masks since there are no adjacent rules with the same match criteria. Policy2.pol consumes two masks since rules one and three are adjacent and have identical match criteria. However, policy1.pol and policy2.pol have different meanings because of precedence. With this being said, you have to be careful to avoid wasting masks. For example consider the following policy:
policy3.pol: entry one { if { source-address 1.1.1.1/32; } then { count debug; } } entry two { if { protocol tcp; destination-port 23; } then { deny; } } entry three { if { source-address 2.2.2.2/32; } then { deny; } }

Policy3.pol consumes three masks. However, since rule entries two and three have the same action, their relative precedence doesn't matter, and they could be swapped without affecting the results of the policy. The following policy accomplishes the same actions, but uses two masks:
policy4.pol: entry one { if { source-address 1.1.1.1/32; } then { count debug; } } entry three { if { source-address 2.2.2.2/32; } then { deny; } } entry two { if { protocol tcp; destination-port 23; } then { deny;

276

ExtremeWare XOS 11.3 Concepts Guide

Applying ACL Policy Files


} }

The only difference between policy3.pol and policy4.pol is that rule entries two and three are swapped. The two policies have the same effect, but policy4.pol does not unnecessarily consume an ACL mask. Mask and Rule Use by Feature: Additionally, certain non-ACL features allocate ACL masks and use ACL rules in order to function. Here are is a list by feature:

dot1p examination1 mask, 8 rules (always enabled) DiffServ examination1 mask, 64 rules (disabled by default) IGMP snooping2 masks, 2 rules (enabled by default) IP interface2 masks, 2 rules (disabled by default) VLAN QoS1 mask, 1 rule per VLAN (disabled by default) port QoS1 mask, 1 rule (disabled by default) VRRP2 masks, 2 rules EAPS1 master config + 1 transit config masks, 1 + number of transit-mode EAPS domains on the port rules ESRP1 mask, 1 rule LLDP1 mask, 1 rule Netlogin1 mask, 1 rule IPv61 mask, 1 rule

ExtremeWare XOS 11.3 Concepts Guide

277

Access Lists (ACLs)

278

ExtremeWare XOS 11.3 Concepts Guide

14 Routing Policies
This chapter describes the following topics:

Routing Policies on page 279 Routing Policy File Syntax on page 279

Policy Match Conditions on page 280 Policy Action Statements on page 283

Applying Routing Policies on page 284 Policy Examples on page 284

Routing Policies
Routing policies are used to control the advertisement or recognition of routes using routing protocols, such as Routing Information Protocol (RIP), Open Shortest Path First (OSPF), or Border Gateway Protocol (BGP). Routing policies can be used to hide entire networks or to trust only specific sources for routes or ranges of routes. The capabilities of routing policies are specific to the type of routing protocol involved, but these policies are sometimes more efficient and easier to implement than access lists. Routing policies can also modify and filter routing information received and advertised by a switch.

Routing Policy File Syntax


The policy file contains one or more policy rule entries. Each routing policy entry consists of:

A policy entry rule name, unique within the same policy. Zero or one match type. If no type is specified, the match type is all, so all match conditions must be satisfied. Zero or more match conditions. If no match condition is specified, then every routing entity matches. Zero or more actions. If no action is specified, the packet is permitted by default.

Each policy entry in the file uses the following syntax:


entry <routingrulename>{ if <match-type> { <match-conditions>; } then { <action>; } }

Here is an example of a policy entry:


entry ip_entry { if match any { nlri 10.203.134.0/24;

ExtremeWare XOS 11.3 Concepts Guide

279

Routing Policies
nlri 10.204.134.0/24; } then { next-hop 192.168.174.92; origin egp; } }

Policy entries are evaluated in order, from the beginning of the file to the end, as follows:

If a match occurs, the action in the then statement is taken:


if the action contains an explicit permit or deny, the evaluation process terminates. if the action does not contain an explicit permit or deny, then the action is an implicit permit, and the evaluation process terminates.

If a match does not occur, then the next policy entry is evaluated. If no match has occurred after evaluating all policy entries, the default action is deny.

Often a policy will have a rule entry at the end of the policy with no match conditions. This entry will match anything not otherwise processed, so that user can specify an action to override the default deny action. The next sections list detailed information about policy match conditions, about matching BGP AS paths, and about action statements. For information on those subjects, see the following sections:

Policy Match Conditions on page 280 Autonomous system expressions on page 281 Policy Action Statements on page 283

Policy Match Type


There are two possible choices for the match type:

match allAll the match conditions must be true for a match to occur. This is the default. match anyIf any match condition is true, then a match occurs.

Policy Match Conditions


Table 36 lists the possible policy entry match conditions.

Table 36: Policy match conditions


Match Condition as-path [<as-number> | <as-path-regularexpression>]; Description Where <as-number> is a valid Autonomous system number in the range [1 - 65535]. Where <as-path-regular-expression> is a multi-character regular expression (with 2-byte unsigned Integer being an Atom). Regular expression will consist of the AS-Numbers and various regular expression symbols. Regular expressions must be enclosed in double quotes ("").

280

ExtremeWare XOS 11.3 Concepts Guide

Routing Policies

Table 36: Policy match conditions (Continued)


Match Condition community [no-advertise | no-export | no-exportsubconfed | number <community_num> | <community_regular_expression> | <as_num> : <num>]; Description Where no-advertise, no-export and no-export-subconfed are the standard communities defined by RFC. <community_num> is a four byte unsigned integer, <as_num> is a two byte AS-Number and <num> is the 2bytes community number. Community regular expression is a multi-character regular expression (with four byte unsigned integer being an Atom). Regular expression is enclosed in double quotes (""). med <number>; next-hop [<ipaddress> | <ipaddress-regularexpression>]; nlri [<ipaddress> | any]/<mask-length> {exact}; nlri [<ipaddress> | any] mask <mask> {exact}; origin [igp | egp | incomplete]; tag <number>; route-origin [direct | static | icmp | egp | ggp | hello | rip | isis | esis | cisco-igrp | ospf | bgp | idrp | dvmrp | mospf | pim-dm | pim-sm | ospf-intra | ospf-inter | ospf-extern1 | ospf-extern2 | bootp | ebgp | i-bgp | mbgp | i-mbgp | e-mbgp | isis-level-1 | isis-level-2 | isis-level-1-external | isis-level-2external] Where <number> is a 4-byte unsigned integer. Where <ipaddress> is a valid IP address in dotted decimal format. Where <ipaddress> and <mask> are IP addresses, <masklength> is an integer, and keyword any matches any IP address with a given (or larger) mask/mask-length. Where igp, egp and incomplete are the Border Gateway Protocol (BGP) route origin values. Where <number> is a 4-byte unsigned number. Matches the origin (different from BGP route origin) of a route. A match statement "route-origin bgp" will match routes whose origin are "I-bgp" or "e-bgp" or "I-mbgp" or "embgp". Similarly, the match statement "route-origin ospf" will match routes whose origin is "ospf-inta" or "ospf-inter" or "ospf-as-external" or "ospf-extern-1" or "ospf-extern-2"

Autonomous system expressions. The AS-path keyword uses a regular expression string to match against the autonomous system (AS) path. Table 37 lists the regular expressions that can be used in the match conditions for Border Gateway Path (BGP) AS path and community. Table 38 shows examples of regular expressions and the AS paths they match.

Table 37: AS regular expression notation


Character N N1 - N2 [Nx ... Ny] [^Nx ... Ny] . ^ $ * + ? { } Definition As number Range of AS numbers, where N1 and N2 are AS numbers and N1 < N2 Group of AS numbers, where Nx and Ny are AS numbers or a range of AS numbers Any AS numbers other than the ones in the group Matches any number Matches the beginning of the AS path Matches the end of the AS path Matches the beginning or end, or a space Separates the beginning and end of a range of numbers Matches 0 or more instances Matches 1 or more instances Matches 0 or 1 instance Start of AS SET segment in the AS path End of AS SET segment in the AS path

ExtremeWare XOS 11.3 Concepts Guide

281

Routing Policies

Table 37: AS regular expression notation (Continued)


Character ( ) Definition Start of a confederation segment in the AS path End of a confederation segment in the AS path

Table 38: Policy regular expression examples


Attribute AS path is 1234 Zero or more occurrences of AS number 1234 Start of As path set End of As path set Path that starts with 99 followed by 34 Path that ends with 99 Path of any length that begins with AS numbers 4, 5, 6 Path of any length that ends with AS numbers 4, 5, 6 Regular Expression 1234 1234* 10 12 { 34 12 } 34 ^99 34 99 $ 4 5 6 .* .* 4 5 6 $ Example Matches 1234 1234 1234 1234 10 12 34 { 99 33 10 12 { 34 37 12 } 34 56 99 34 45 45 66 99 456456789 456 123456

Here are some additional examples of using regular expressions in the AS-Path statement. The following AS-Path statement matches AS paths that contain only (begin and end with) AS number 65535:
as-path "^65535$"

The following AS-Path statement matches AS paths beginning with AS number 65535, ending with AS number 14490, and containing no other AS paths:
as-path "^65535 14490$"

The following AS-Path statement matches AS paths beginning with AS number 1, followed by any AS number from 2 - 8, and ending with either AS number 11, 13, or 15:
as-path "^1 2-8 [11 13 15]$"

The following AS-Path statement matches AS paths beginning with AS number 111 and ending with any AS number from 2 - 8:
as-path "111 [2-8]$"

The following AS-Path statement matches AS paths beginning with AS number 111 and ending with any additional AS number, or beginning and ending with AS number 111:
as-path "111 .?"

282

ExtremeWare XOS 11.3 Concepts Guide

Routing Policies

Policy Action Statements


Table 39 lists the possible action statements. These are the actions taken when the policy match conditions are met in a policy entry.

Table 39: Policy actions


Action as-path "<as_num> {<as_num1> <as_num2> <as_num3> . <as_numN>}"; community [no-advertise | no-export | no-exportsubconfed | <community_num> {<community_num1> <community_num2> . <community_numN>} | <as_num> : <community_num> [<as_num1> <community_num1> <as_num2> <community_num2> .}]; community [add | delete] [no-advertise | no-export | no-export-subconfed | <community_num> {<community_num1> <community_num2> . <community_numN>} | <as_num> : <community_num> {<as_num1> <community_num1> <as_num2> <community_num2> .}]; community remove; cost <cost(0-4261412864)>; cost-type {ase-type-1 | ase-type-2 | external | internal}; dampening half-life <minutes (1-45)> reuse-limit <number (1-20000)> suppress-limit <number (120000)> max-suppress <minutes (1-255)>; deny; local-preference <number>; med {add | delete} <number>; Description Prepends the entire list of as-numbers to the as-path of the route. Replaces the existing community attribute of a route by the communities specified by the action statement. Communities must be enclosed in double quotes ("").

Adds/deletes communities to/from a route's community attribute. Communities must be enclosed in double quotes ("").

Strips off the entire community attribute from a route. Communities must be enclosed in double quotes (""). Sets the cost/metric for a route. Sets the cost type for a route. Sets the BGP route flap dampening parameters.

Denies the route. Sets the BGP local preference for a route. Performs MED arithmetic. Add means the value of the MED in the route will be incremented by <number>, and delete means the value of the MED in the route will be decremented by <number>. Internal means that the Interior Gateway Protocol (IGP) distance to the next hop will be taken as the MED for a route. Remove means take out the MED attribute from the route. Sets the MED attribute for a route. Sets the next hop attribute for a route. These set statements are used for building a list of IP addresses. This is used by PIM to set up the RP list. Sets the BGP route origin values. Permits the route. Sets the tag number for a route. Sets the weight for a BGP route.

med {internal | remove};

med set <number>; next-hop <ipaddress>; nlri [<ipaddress> | any]/<mask-length> {exact}; nlri [<ipaddress> | any] mask <mask> {exact}; origin {igp | egp | incomplete}; permit; tag <number>; weight <number>

ExtremeWare XOS 11.3 Concepts Guide

283

Routing Policies

Applying Routing Policies


To apply a routing policy, use the command appropriate to the client. Different protocols support different ways to apply policies, but there are some generalities. Policies applied with commands that use the keyword import-policy control the routes imported to the protocol from the switch routing table. The following are examples for the BGP and RIP protocols:
configure bgp import-policy [<policy-name> | none] configure rip import-policy [<policy-name> | none]

Commands that use the keyword route-policy control the routes advertised or received by the protocol. For BGP and RIP, here are some examples:
configure bgp neighbor [<remoteaddr> | all] {address-family [ipv4-unicast | ipv4multicast]} route-policy [in | out] [none | <policy>] configure bgp peer-group <peer-group-name> route-policy [in | out] [none | <policy>] configure rip vlan [<vlan-name> | all] route-policy [in | out] [<policy-name> | none]

Other examples of commands that use route policies include:


configure ospf area <area-identifier> external-filter [<policy-map> |none] configure ospf area <area-identifier> interarea-filter [<policy-map> | none] configure rip vlan [<vlan-name> | all] trusted-gateway [<policy-name> | none]

To remove a routing policy, use the none option in the command.

Policy Examples
The following sections contain examples of policies. The examples are:

Translating an access profile to a policy on page 284 Translating a route map to a policy on page 286

Translating an access profile to a policy


You may be more familiar with using access profiles on other Extreme Networks switches. This example shows the policy equivalent to an ExtremeWare access profile. ExtremeWare Access-Profile:
Seq_No 5 10 15 20 25 Action permit permit deny permit deny IP Address 22.16.0.0 192.168.0.0 any 10.10.0.0 22.44.66.0 IP Mask 255.252.0.0 255.255.192.0 255.0.0.0 255.255.192.0 255.255.254.0 Exact No Yes No No Yes

284

ExtremeWare XOS 11.3 Concepts Guide

Routing Policies Equivalent ExtremeWare XOS policy map definition:


entry entry-5 { If { nlri 22.16.0.0/14; } then { permit; } } entry entry-10 { if { nlri 192.168.0.0/18 exact; } then { permit; } } entry entry-15 { if { nlri any/8; } then { deny; } } entry entry-20 { if { nlri 10.10.0.0/18; } then { permit; } } entry entry-25 { if { nlri 22.44.66.0/23 } then { deny; } }

exact;

The policy above can be optimized by combining some of the if statements into a single expression. The compact form of the policy will look like this:
entry permit_entry { If match any { nlri 22.16.0.0/14; nlri 192.168.0.0/18 exact ; nlri 10.10.0.0/18; }

ExtremeWare XOS 11.3 Concepts Guide

285

Routing Policies
then { permit; } } entry deny_entry { if match any { nlri any/8; nlri 22.44.66.0/23 } then { deny; } }

exact;

Translating a route map to a policy


You may be more familiar with using route maps on other Extreme Networks switches. This example shows the policy equivalent to an ExtremeWare route map. ExtremeWare route map:
Route Map : rt Entry : 10 Action : permit match origin incomplete Entry : 20 Action : deny match community 6553800 Entry : 30 Action : permit match med 30 set next-hop 10.201.23.10 set as-path 20 set as-path 30 set as-path 40 set as-path 40 Entry : 40 Action : permit set local-preference 120 set weight 2 Entry : 50 Action : permit match origin incomplete match community 19661200 set dampening half-life 20 reuse-limit 1000 suppress-limit 3000 max-suppress 40 Entry : 60 Action : permit match next-hop 192.168.1.5 set community add 949616660

Here is the equivalent policy:


entry entry-10 { If { origin incomplete; } then { permit; }

286

ExtremeWare XOS 11.3 Concepts Guide

Routing Policies
} entry if entry-20 { community { 6553800;

} then { deny; } } entry if entry-30 { med 30; {

} then { next-hop 10.201.23.10; as-path 20; as-path 30; as-path 40; as-path 40; permit; } } entry if entry-40 { {

} then { local-preference 120; weight 2; permit; } } entry if entry-50 match any { { origin incomplete; community 19661200;

} then { dampening half-life 20 reuse-limit 1000 suppress-limit 3000 max-suppress 40 permit; } } entry if entry-60 { { next-hop 192.168.1.5;

} then { community permit; } }

add

949616660;

ExtremeWare XOS 11.3 Concepts Guide

287

Routing Policies

entry deny_rest { if { } then { deny; } }

288

ExtremeWare XOS 11.3 Concepts Guide

15 Quality of Service
This chapter covers the following topics:

Overview of Policy-Based Quality of Service on page 289 Applications and Types of QoS on page 290 Configuring QoS on page 292 QoS Profiles on page 293 Traffic Groupings on page 295 Verifying QoS Configuration and Performance on page 307 Guidelines for Configuring QoS on page 309 Egress Traffic Rate LimitingBlackDiamond 8800 Family of Switches and Summit X450 Switch Only on page 309 Bi-Directional Rate ShapingBlackDiamond 10K Switch Only on page 310

Policy-based Quality of Service (QoS) is a feature of ExtremeWare XOS and the Extreme Networks switch architecture that allows you to specify different service levels for traffic traversing the switch. Policy-based QoS is an effective control mechanism for networks that have heterogeneous traffic patterns. Using Policy-based QoS, you can specify the service level that a particular traffic type receives.

Overview of Policy-Based Quality of Service


Policy-based Quality of Service (QoS) is a feature of ExtremeWare XOS and the Extreme Networks switch architecture that allows you to specify different service levels for traffic traversing the switch. Policy-based QoS is an effective control mechanism for networks that have heterogeneous traffic patterns. Using Policy-based QoS, you can specify the service level that a particular traffic type receives. Policy-based QoS allows you to protect bandwidth for important categories of applications or to specifically limit the bandwidth associated with less critical traffic. For example, if voice-over-IP (VoIP) traffic requires a reserved amount of bandwidth to function properly, using policy-based QoS, you can reserve sufficient bandwidth critical to this type of application. Other applications deemed less critical can be limited so as to not consume excessive bandwidth. On the BlackDiamond 10K switch, the switch contains separate hardware queues on every physical port. On the BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch, the switch has two default queues (based on flows), and you can configure up to six additional queues. Each queue is programmed by ExtremeWare XOS with specific parameters that modify the forwarding behavior of the switch and affect how the switch transmits traffic for a given queue on a physical port. The switch tracks and enforces the specified parameters on every queue for every port. When two or more queues on the same physical port are contending for transmission, the switch prioritizes use so long as the respective queue management parameters are satisfied. Up to eight queues per port are available.

ExtremeWare XOS 11.3 Concepts Guide

289

Quality of Service

NOTE
Policy-based QoS has no impact on switch performance. Using even the most complex traffic groupings has no cost in terms of switch performance.

Applications and Types of QoS


Different applications have different QoS requirements. The following applications are ones that you will most commonly encounter and need to prioritize:

Voice applications Video applications Critical database applications Web browsing applications File server applications

General guidelines for each traffic type are given below and summarized in Table 40. Consider them as general guidelines and not as strict recommendations. After QoS parameters have been set, you can monitor the performance of the application to determine if the actual behavior of the applications matches your expectations. It is very important to understand the needs and behavior of the particular applications you want to protect or limit. Behavioral aspects to consider include bandwidth needs, sensitivity to latency and jitter, and sensitivity and impact of packet loss.

Voice Applications
Voice applications, or voice over IP (VoIP), typically demand small amounts of bandwidth. However, the bandwidth must be constant and predictable because voice applications are typically sensitive to latency (inter-packet delay) and jitter (variation in inter-packet delay). The most important QoS parameter to establish for voice applications is minimum bandwidth, followed by priority.

Video Applications
Video applications are similar in needs to voice applications, with the exception that bandwidth requirements are somewhat larger, depending on the encoding. It is important to understand the behavior of the video application being used. For example, in the playback of stored video streams, some applications can transmit large amounts of data for multiple streams in one spike, with the expectation that the endstations will buffer significant amounts of video-stream data. This can present a problem to the network infrastructure, because the network must be capable of buffering the transmitted spikes where there are speed differences (for example, going from gigabit Ethernet to Fast Ethernet). Key QoS parameters for video applications include minimum bandwidth and priority, and possibly buffering (depending upon the behavior of the application).

290

ExtremeWare XOS 11.3 Concepts Guide

Applications and Types of QoS

Critical Database Applications


Database applications, such as those associated with Enterprise Resource Planning (ERP), typically do not demand significant bandwidth and are tolerant of delay. You can establish a minimum bandwidth using a priority less than that of delay-sensitive applications.

Web Browsing Applications


QoS needs for Web browsing applications cannot be generalized into a single category. For example, ERP applications that use a browser front-end may be more important than retrieving daily news information. Traffic groupings can typically be distinguished from each other by their server source and destinations. Most browser-based applications are distinguished by the dataflow being asymmetric (small dataflows from the browser client, large dataflows from the server to the browser client). An exception to this may be created by some Java -based applications. In addition, Web-based applications are generally tolerant of latency, jitter, and some packet loss; however, small packet loss may have a large impact on perceived performance because of the nature of TCP. The relevant parameter for protecting browser applications is minimum bandwidth. The relevant parameter for preventing non-critical browser applications from overwhelming the network is maximum bandwidth.

File Server Applications


With some dependencies on the network operating system, file serving typically poses the greatest demand on bandwidth, although file server applications are very tolerant of latency, jitter, and some packet loss, depending on the network operating system and the use of TCP or UDP. NOTE
Full-duplex links should be used when deploying policy-based QoS. Half-duplex operation on links can make delivery of guaranteed minimum bandwidth impossible.

Table 40 summarizes QoS guidelines for the different types of network traffic.

Table 40: Traffic type and QoS guidelines


Traffic type Voice Video Database Web browsing File server Key QoS parameters Minimum bandwidth, priority Minimum bandwidth, priority, buffering (varies) Minimum bandwidth Minimum bandwidth for critical applications, maximum bandwidth for noncritical applications Minimum bandwidth

ExtremeWare XOS 11.3 Concepts Guide

291

Quality of Service

Configuring QoS
NOTE
With software version 11.0, you can create access control lists (ACLs) with QoS actions. The QoS forwarding information you configured in an ACL takes precedence over QoS configuration using the CLI commands. Refer to Chapter 13 for more information on ACLs.

To configure QoS, you define how your switch responds to different categories of traffic by creating and configuring QoS profiles. You then group traffic into categories (according to the needs of the application, as previously discussed) and assign each category to a QoS profile. Configuring QoS is a three-step process: 1 Configure the QoS profile. QoS profileA class of service that is defined through minimum and maximum bandwidth parameters and prioritization settings on the BlackDiamond 10K switch or through configuration of buffering and scheduling settings on the BlackDiamond 8800 family of switches and the Summit X450 switch. The level of service that a particular type of traffic or traffic grouping receives is determined by assigning it to a QoS profile. The names of the QoS profiles are QP1 through QP8; these names are not configurable. 2 Create traffic groupings. Traffic groupingA classification or traffic type that has one or more attributes in common. These can range from a physical port to IP Layer 4 port information. You assign traffic groupings to QoS profiles to modify switch forwarding behavior. Traffic groupings transmitting out the same port that are assigned to a particular QoS profile share the assigned characteristics and hence share the class of service. 3 Monitor the performance of the application with the QoS monitor to determine whether the policies are meeting the desired results.

Configuring QoS on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
The BlackDiamond 8800 family of switches and the Summit X450 switch allow dynamic creation and deletion of QoS queues, with Q1 and Q8 always available, rather than the 8 fixed queues on the BlackDiamond 10K switch. NOTE
The sFlow application uses QP2 to sample traffic on the BlackDiamond 8800 family of switches and the Summit X450 switch. Any traffic grouping using QP2 may encounter unexpected results when sFlow is enabled.

The following considerations apply only to QoS on the BlackDiamond 8800 family of switches and the Summit X450 switch:

The BlackDiamond 8800 family of switches and the Summit X450 switch do not support QoS monitor. The following QoS features share resources on the BlackDiamond 8800 family of switches and the Summit X450 switch:

ACLs

292

ExtremeWare XOS 11.3 Concepts Guide

QoS Profiles

DiffServ dot1p VLAN-based QoS Port-based QoS

You may receive an error message when configuring a QoS feature in the above list on the BlackDiamond 8800 family of switches and the Summit X450 switch; it is possible that the shared resource is depleted. In this case, unconfigure one of the other QoS features and reconfigure the one you are working on.

The next sections describe each of these QoS components in detail.

QoS Profiles
QoS profiles are configured differently:

On the BlackDiamond 8800 family of switches and the Summit X450 switch On the BlackDiamond 10K switch.

QoS Profiles on the BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
The BlackDiamond 8800 family of switches and the Summit X450 switch have two default queues, QP1 and QP8, which are based on traffic flows. QP1 has the lowest priority, and QP8 has the highest priority. You can configure up to six additional QoS profiles, or queues, on the switch, QP2 through QP7. Creating a queue dynamically will not cause loss of traffic. You can also modify the default parameters of each QoS profile. The names of the QoS profiles, QP1 through QP8, are not configurable. The parameters that make up a QoS profile on the BlackDiamond 8800 family of switches and the Summit X450 switch include:

BufferThis parameter is the maximum amount of packet buffer memory available to all packets associated with the configured QoS profile within all affected ports. All QoS profiles use 100% of available packet buffer memory by default. You can configure the buffer amount from 1 to 100%, in whole integers. Regardless of the maximum buffer setting, the system does not drop any packets if any packet buffer memory remains to hold the packet and the current QoS profile buffer use is below the maximum setting. NOTE
Use of all 8 queues on all ports may result in insufficient buffering to sustain 0 packet loss throughput during full-mesh connectivity with large packets.

WeightThis parameter is the relative weighting for each QoS profile; 1 through 16 are the available weight values. The default value for each QoS profile is 1, giving each queue equal weighting. When you configure a QoS profile with a weight of 4, that queue is serviced 4 times as frequently as a queue with a weight of 1. However, if you configure all QoS profiles with a weight of 16, each queue is serviced equally but for a longer period of time.

Finally, you configure the scheduling method that the entire switch will use to empty the queues. The scheduling applies globally to the entire switch, not to each port. You can configure the scheduling to be

ExtremeWare XOS 11.3 Concepts Guide

293

Quality of Service strict priority, which is the default, or weighted round robin. In the strict priority method, the switch services the higher-priority queues first. As long as a queued packet remains in a higher-priority queue, any lower-priority queues are not serviced. If you configure the switch for weighted-round-robin scheduling, the system services all queues based on the weight assigned to the QoS profile. The hardware services higher-weighted queues more frequently, but lower-weighted queues continue to be serviced at all times. When configured to do so, the priority of a QoS profile can determine the 802.1p bits used in the priority field of a transmitted packet (see Replacing 802.1p priority information on page 299). The priority of a QoS profile determines the DiffServ code point value used in an IP packet when the packet is transmitted (see Replacing DiffServ code points on page 301). A QoS profile switch does not alter the behavior of the switch until it is assigned to a traffic grouping. The default QoS profiles cannot be deleted. The settings for the default QoS parameters on the BlackDiamond 8800 family of switches and the Summit X450 switch are summarized in Table 41.

Table 41: Default QoS profile parameters on the BlackDiamond 8800 family of switches and the Summit X450 switch
Profile name QP1 QP8 Priority Low High Buffer 100% 100% Weight 1 1

QoS Profiles on the BlackDiamond 10K Switch


The BlackDiamond 10K switch has 8 hardware queues for each egress port. The QoS profiles, QP1 to QP8, map to these hardware queues. A QoS profile on the BlackDiamond 10K switch defines a class of service by specifying traffic behavior attributes, such as bandwidth. The parameters that make up a QoS profile on the BlackDiamond 10K switch include:

Minimum bandwidthThe minimum total link bandwidth that is reserved for use by a hardware queue on a physical port (each physical port has eight hardware queues, corresponding to a QoS profile). The minimum bandwidth value is configured either as a percentage of the total link bandwidth or using absolute committed rates in Kbps or Mbps. Bandwidth unused by the queue can be used by other queues. The minimum bandwidth for all queues should add up to less than 100%. The default value on all minimum bandwidth parameters is 0%. Maximum bandwidthThe maximum total link bandwidth that can be transmitted by a hardware queue on a physical port (each physical port has eight hardware queues, corresponding to a QoS profile). The maximum bandwidth value is configured either as a percentage of the total link bandwidth or using absolute peak rates in Kbps or Mbps. The default value on all maximum bandwidth parameters is 100%. PriorityThe level of priority assigned to a hardware egress queue on a physical port. There are eight different available priority settings and eight different hardware queues. By default, each of the default QoS profiles is assigned a unique priority. You use prioritization when two or more hardware queues on the same physical port are contending for transmission on the same physical port, only after their respective bandwidth management parameters have been satisfied. If two hardware queues on the same physical port have the same priority, a round-robin algorithm is used for transmission, depending on the available link bandwidth.

When configured to do so, the priority of a QoS profile can determine the 802.1p bits used in the priority field of a transmitted packet (see Replacing 802.1p priority information on page 299).

294

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings

The priority of a QoS profile determines the DiffServ code point value used in an IP packet when the packet is transmitted (see Replacing DiffServ code points on page 301).

A QoS profile does not alter the behavior of the switch until it is assigned to a traffic grouping. Recall that QoS profiles on the BlackDiamond 10K switch are linked to hardware queues. There are multiple hardware queues per physical port. By default, a QoS profile links to the identical hardware queue across all the physical ports of the switch. The default QoS profiles cannot be deleted. Also by default, a QoS profile maps directly to a specific hardware queue across all physical ports. The settings for the default QoS parameters on the BlackDiamond 10K switch are summarized in Table 42.

Table 42: Default QoS profile parameters on the BlackDiamond 10K switch
Profile name QP1 QP2 QP3 QP4 QP5 QP6 QP7 QP8 Hardware queue Q0 Q1 Q2 Q3 Q4 Q50 Q6 Q7 Priority Low LowHi Normal NormalHi Medium MediumHi High HighHi Minimum bandwidth 0% 0% 0% 0% 0% 0% 0% 0% Maximum bandwidth 100% 100% 100% 100% 100% 100% 100% 100%

Traffic Groupings
After a QoS profile has been created or modified, you assign a traffic grouping to the profile. A traffic grouping is a classification of traffic that has one or more attributes in common. Traffic is typically grouped based on the needs of the applications discussed starting on page 290. Traffic groupings are separated into the following categories for discussion:

ACL-based information Explicit packet class of service information, such as 802.1p or DiffServ (IP TOS) Physical/Logical configuration (physical source port or VLAN association)

Precedence of Traffic Groupings


In the event that a given packet matches two or more grouping criteria, there is a predetermined precedence for which traffic grouping applies. The supported traffic groupings, by precedence, are listed in the following:

Access list groupings (ACLs)


IP ACL MAC ACL DiffServ (IP TOS) 802.1p

Explicit packet class of service groupings


ExtremeWare XOS 11.3 Concepts Guide

295

Quality of Service

Physical/logical groupings

Source port VLAN NOTE

The source port and VLAN QoS apply only to untagged packets, and 802.1p QoS applies only to tagged packets. If you use 802.1p or DiffServ QoS in conjunction with ACLs, you must configure the 802.1p or DiffServ action within the ACL itself.

In general, the more specific traffic grouping takes precedence. Those groupings listed at the top of the table are evaluated first. By default, all traffic groupings are placed in the QoS profile QP1. The groupings are listed in order of precedence (highest to lowest). The three types of traffic groupings are described in detail on the following pages.

NOTE
On the BlackDiamond 8800 family of switches and the Summit X450 switch, the precedence of IP ACL or MAC ACL depends on specifications in the ACL file itself. Refer to Chapter 13 for more information on ACLs.

ACL-Based Traffic Groupings


ACL-based traffic groupings are based on any combination of the following items:

IP source or destination address IP protocol TCP flag TCP/UDP or other Layer 4 protocol TCP/UDP port information IP fragmentation MAC source or destination address Ethertype

ACL-based traffic groupings are defined using access lists. Access lists are discussed in detail in Chapter 13. By supplying a named QoS profile on an ACL rule, you can prescribe the bandwidth management and priority handling for that traffic grouping. This level of packet filtering has no impact on performance.

Explicit Class of Service (802.1p and DiffServ) Traffic Groupings


This category of traffic groupings describes what is sometimes referred to as explicit packet marking, and refers to information contained within a packet intended to explicitly determine a class of service. That information includes:

Prioritization bits used in IEEE 802.1p packets IP Differentiated Services (DiffServ) code points, formerly known as IP Type of Service (TOS) bits

An advantage of explicit packet marking is that the class of service information can be carried throughout the network infrastructure, without repeating what can be complex traffic grouping policies

296

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings at each switch location. Another advantage is that endstations can perform their own packet marking on an application-specific basis. Extreme Networks switch products have the capability of observing and manipulating packet marking information with no performance penalty. The documented capabilities for 802.1p priority markings or DiffServ capabilities (if supported) are not impacted by the switching or routing configuration of the switch. For example, 802.1p information can be preserved across a routed switch boundary and DiffServ code points can be observed or overwritten across a Layer 2 switch boundary. This section covers the following topics:

Configuring 802.1p priority Configuring DiffServ

Configuring 802.1p Priority


Extreme Networks switches support the standard IEEE 802.1p priority bits that are part of a tagged Ethernet packet. The 802.1p bits can be used to prioritize the packet and to assign that packet to a particular QoS profile. When a tagged packet arrives at the switch, the switch examines the 802.1p priority field and maps the packet to a specific queue when subsequently transmitting the packet. The 802.1p priority field is located directly following the 802.1Q type field and preceding the 802.1Q VLAN ID, as shown in Figure 14.

Figure 14: Ethernet packet encapsulation


802.1Q type 8100 802.1p priority 802.1Q VLAN ID

Destination address

Source address

IP packet

CRC
EW_024

This section covers the following topics:


802.1p information on the BlackDiamond 10K only Observing the 802.1p information Changing the default 802.1p mapping Replacing 802.1p information

ExtremeWare XOS 11.3 Concepts Guide

297

Quality of Service 802.1p information on the BlackDiamond 10K only. If a port is in more than one virtual router, you cannot use the QoS 802.1p features. The default VLAN DiffServ examination mappings apply on ports in more than one VR. If you attempt to configure examining or replacing 802.1p information on a port that is in more than one virtual router, the system returns the following message:
Warning: Port belongs to more than one VR. Port properties related to diff serv and code replacement will not take effect.

Observing 802.1p information. When ingress traffic that contains 802.1p prioritization information is detected by the switch, that traffic is mapped to various queues on the egress port of the switch. The BlackDiamond 10K switch supports 8 hardware queues by default; you can modify the characteristics of each queue. By default, the BlackDiamond 8800 family of switches and the Summit X450 switch support 2 queues based on flows; you can define up to 6 additional queues. The transmitting queue determines the characteristics used when transmitting packets.

NOTE
See for Chapter 9 information regarding VMANs using 802.1p information to direct packets to appropriate egress QoS queues.

To control the mapping of 802.1p prioritization values to queues, 802.1p prioritization values can be mapped to a QoS profile. The default mapping of each 802.1p priority value to QoS profile is shown in Table 43.

Table 43: Default 802.1p priority value-to-QoS profile mapping


Priority value 0 1 2 3 4 5 6 7 BlackDiamond 10K switch default QoS profile QP1 QP2 QP3 QP41 QP5 QP6 QP7 QP8 BlackDiamond 8800 family of switches and Summit X450 switch default QoS profile QP1 QP1 QP1 QP1 QP1 QP1 QP1 QP8

Changing the default 802.1p mapping. By default, a QoS profile is mapped to a queue, and each QoS profile has configurable parameters. In this way, an 802.1p priority value seen on ingress can be mapped to a particular QoS profile. To change the mapping of 802.1p priority value to QoS profile, use the following command:
configure dot1p type <dot1p_priority> {qosprofile} <qosprofile>

298

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings Replacing 802.1p priority information. By default, 802.1p priority information is not replaced or manipulated, and the information observed on ingress is preserved when transmitting the packet. This behavior is not affected by the switching or routing configuration of the switch. NOTE
In the BlackDiamond 8800 family of switches and the Summit X450 switch, 802.1p replacement uses existing flow classifiers. If this feature is enabled and the flow classifier has been defined (traffic groupings), the related flow classifier causes the replacement.

However, the switch is capable of inserting and/or overwriting 802.1p priority information when it transmits an 802.1Q tagged frame. If 802.1p replacement is enabled, the 802.1p priority information that is transmitted is determined by the queue that is used when transmitting the packet. The 802.1p replacement configuration is based on the ingress port. To replace 802.1p priority information, use the following command:
enable dot1p replacement ports [<port_list> | all]

NOTE
The port in this command is the ingress port.

To disable this feature, use the following command:


disable dot1p replacement ports [<port_list> | all]

NOTE
On the BlackDiamond 8800 family of switches and the Summit X450 switch, only QP1 and QP8 exist by default; you must create QP2 to QP7. If you have not created these QPs, the replacement feature will not take effect.

The 802.1p priority information is replaced according to the queue that is used when transmitting from the switch. The mapping is described in Table 44. This mapping cannot be changed.

Table 44: Queue-to-802.1p priority replacement value


802.1p priority replacement value 0 1 2 3 4 5 6 7 BlackDiamond 10K switch hardware queue Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 BlackDiamond 8800 family of switches and Summit X450 switch 802.1p queue Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8

NOTE
This command affects only that traffic based on explicit packet class of service information and physical/logical configuration.

ExtremeWare XOS 11.3 Concepts Guide

299

Quality of Service

Configuring DiffServ
Contained in the header of every IP packet is a field for IP Type of Service (TOS), now also called the Differentiated Services (DiffServ) field. The DiffServ field is used by the switch to determine the type of service provided to the packet. Figure 15 shows the encapsulation of an IP packet header.

Figure 15: IP packet header encapsulation


0 1 2 3 4 5 6 7

DiffServ code point 0 Version bits IHL Type-of-service Flags Protocol Source address Destination address Options (+ padding) Data (variable)
EW_023

31 Total length Fragment offset

Identification Time-to-live

Header checksum

Observing DiffServ code points as a traffic grouping mechanism for defining QoS policies and overwriting the Diffserv code point fields are supported. This section covers the following sections:

DiffServ information on the BlackDiamond 10K only Observing DiffServ information Changing DiffServ code point (DSCP) mapping Replacing DSCP information

DiffServ information on the BlackDiamond 10K only. The default VLAN DiffServ examination mappings apply on ports in more than one VR. If you attempt to configure examining or replacing DiffServ information on a port that is in more than one virtual router, the system returns the following message:
Warning: Port belongs to more than one VR. Port properties related to diff serv and code replacement will not take effect.

300

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings Observing DiffServ information. When a packet arrives at the switch on an ingress port and this feature is enabled, the switch examines the first six of eight TOS bits, called the DiffServ code point. The switch can then assign the QoS profile used to subsequently transmit the packet based on the code point. The QoS profile controls which queue is used when transmitting the packet out of the switch and determines the forwarding characteristics of a particular code point. Examining DiffServ information can be enabled or disabled; by default it is disabled. To enable DiffServ examination, use the following command:
enable diffserv examination port [<port_list> | all]

To disable DiffServ examination, use the following command:


disable diffserv examination port [<port_list> | all]

Because the DiffServ code point uses six bits, it has 64 possible values (26 = 64). By default, the values are grouped and assigned to the default QoS profiles listed in Table 45.

Table 45: Default DiffServ code point-to-QoS profile mapping


Code point 0-7 8-15 16-23 24-31 32-39 40-47 48-55 56-63 BlackDiamond 10K switch QoS profile QP1 QP2 QP3 QP4 QP5 Q61 QP7 QP8 BlackDiamond 8800 family of switches and the Summit X450 switch QoS profile QP1 QP1 QP1 QP1 QP1 QP1 QP1 QP8

Changing the default DiffServ code point mapping . You can change the QoS profile assignment for each of the 64 code points using the following command:
configure diffserv examination code-point <code-point> {qosprofile} <qosprofile>

Once assigned, the rest of the switches in the network prioritize the packet using the characteristics specified by the QoS profile. Replacing DiffServ code points. The switch can be configured to change the DiffServ code point in the packet prior to the packet being transmitted by the switch. This is done with no impact on switch performance. The DiffServ code point value used in overwriting the original value in a packet is determined by the QoS profile. You enter the QoS profile you want to use to determine the replacement DiffServ code point value. To replace DiffServ code points, you must enable DiffServ replacement using the following commands
enable diffserv replacement ports [<port_list> | all]

NOTE
The port in this command is the ingress port. This command affects only that traffic based on explicit packet class of service information and physical/logical configuration.

ExtremeWare XOS 11.3 Concepts Guide

301

Quality of Service To disable this feature, use the following command:


disable diffserv replacement port [<port_list> | all]

The default QoS profile to DiffServ code point mapping is shown in Table 46, and the default 802.1p priority value to code point mapping is described in Table 46.

Table 46: Default 802.1p priority value-to-DiffServ code point mapping


BlackDiamond 10K switch QoS profile QP1 QP2 QP3 QP4 QP5 QP61 QP7 QP8 BlackDiamond 8800 family of switches and the Summit X450 switch QoS profile QP1 QP1 QP1 QP1 QP1 QP1 QP1 QP8 802.1p priority value 0 1 2 3 4 5 6 7 Code point 0 8 16 24 32 40 48 56

You change the DiffServ code point mapping, using either the QoS profile or the 802.1p value, to any code point value using the following command:
configure diffserv replacement [{qosprofile} <qosprofile> | priority <value>] codepoint <code_point>

NOTE
Extreme Networks recommends that you use the qosprofile <qosprofile> value to configure this parameter.

By doing so, the queue used to transmit a packet determines the DiffServ value replaced in the IP packet. To view currently configured DiffServ information, use the following command:
show diffserv [examination | replacement]

DiffServ example for the BlackDiamond 8800 family of switches and the Summit X450 switch. In this example on the BlackDiamond 8800 family of switches and the Summit X450 switch, we use DiffServ to signal a class of service throughput and assign any traffic coming from network 10.1.2.x with a specific DiffServ code point. This allows all other network switches to send and observe the Diffserv code point instead of repeating the same QoS configuration on every network switch.

302

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings To configure the switch, follow these steps: 1 Using ACLs, assign a traffic grouping for traffic from network 10.1.2.x to QP3:
configure access-list qp3sub any

The following is a sample policy file example:


#filename: qp3sub.pol entry QP3-subnet { if { source-address 10.1.2.0/24 } then { Qosprofile qp3; }

2 Configure the switch so that other switches can signal calls of service that this switch should observe by entering the following:
enable diffserv examination ports all

DiffServ example for the BlackDiamond 10K switch. In this example on the BlackDiamond 10K switch, we use DiffServ to signal a class of service throughput and assign any traffic coming from network 10.1.2.x with a specific DiffServ code point. This allows all other network switches to send and observe the Diffserv code point instead of repeating the same QoS configuration on every network switch. To configure the switch, follow these steps: 1 Using ACLs, assign a traffic grouping for traffic from network 10.1.2.x to QP3:
configure access-list qp3sub any

The following is a sample policy file example:


#filename: qp3sub.pol entry QP3-subnet { if { source-address 10.1.2.0/24 } then { Qosprofile qp3; replace-dscp; }

2 Configure the switch so that other switches can signal calls of service that this switch should observe by entering the following:
enable diffserv examination ports all

NOTE
The switch only observes the DiffServ code points if the traffic does not match the configured access list. Otherwise, the ACL QoS setting overrides the QoS DiffServ configuration.

ExtremeWare XOS 11.3 Concepts Guide

303

Quality of Service

Physical and Logical Groupings


Two traffic groupings exist in this category:

Source port VLAN

Source port
A source port traffic grouping implies that any traffic sourced from this physical port uses the indicated QoS profile when the traffic is transmitted out to any other port. To configure a source port traffic grouping, use the following command:
configure ports <port_list> {qosprofile} <qosprofile>

In the following modular switch example, all traffic sourced from slot 5 port 7 uses the QoS profile named QP8 when being transmitted.
configure ports 5:7 qosprofile qp8

NOTE
On the BlackDiamond 10K switch, this command applies only to untagged packets. On the BlackDiamond 8800 family of switches and the Summit X450 switch, this command applies to all packets.

VLAN
A VLAN traffic grouping indicates that all intra-VLAN switched traffic and all routed traffic sourced from the named VLAN uses the indicated QoS profile. To configure a VLAN traffic grouping, use the following command:
configure vlan <vlan_name> {qosprofile} <qosprofile>

For example, all devices on VLAN servnet require use of the QoS profile QP1. The command to configure this example is as follows:
configure vlan servnet qosprofile qp1

NOTE
On the BlackDiamond 10K switch, this command applies only to untagged packets. On the BlackDiamond 8800 family of switches and the Summit X450 switch, this command applies to all packets.

Verifying Physical and Logical Groupings


You can display QoS settings on the ports or VLANs. NOTE
On the BlackDiamond 10K switch, the screen displays both ingress and egress QoS settings. The 10Gbps ports have 8 ingress queues, and the 1 Gbps ports have 2 ingress queues.(Refer to Bi-Directional Rate Shaping BlackDiamond 10K Switch Only on page 310 for more information on ingress queues, or bi-directional rate shaping.)

304

ExtremeWare XOS 11.3 Concepts Guide

Traffic Groupings To verify settings on ports or VLANs, use the following command:
show ports {mgmt | <port_list>} information {detail}

BlackDiamond 8800 family of switches and Summit X450 switch display. You display which QoS profile, if any, is configured on the BlackDiamond 8800 family of switches and the Summit X450 switch using the show ports <port_list> information detail command. Following is a sample output of this command for an BlackDiamond 8810 switch:
Port: 8:1 Virtual-router: VR-Default Type: EW Random Early drop: Disabled Admin state: Enabled with auto-speed sensing auto-duplex Link State: Active Link Counter: Up 1 time(s) VLAN cfg: Name: Default, Internal Tag = 1, MAC-limit = No-limit STP cfg: s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported Egress Port Rate: No-limit Broadcast Rate: No-limit Multicast Rate: No-limit Unknown Dest Mac Rate: No-limit QoS Profile: Qp3 Configured by user Ingress Rate Shaping : Unsupported Ingress IPTOS Examination: Disabled Egress IPTOS Replacement: Disabled Egress 802.1p Replacement: Disabled NetLogIn: Disabled Smart redundancy: Enabled Software redundant port: Disabled Match all protocols.

NOTE
To ensure that you display the QoS information, you must use the detail variable.

BlackDiamond 10K switch display. You display information on the egress QoS profiles and the ingress QoS profiles (shown as Ingress Rate Shaping), as well as the minimum and maximum available bandwidth and priority on the BlackDiamond 10 K switch using the show ports <port_list> information detail command. The display is slightly different for a 1 Gbps port and for a 10 Gbps port.

ExtremeWare XOS 11.3 Concepts Guide

305

Quality of Service Following is sample output of this command for a BlackDiamond 10K switch 10 Gbps port:
Port: 8:1 Virtual-router: VR-Default Type: XENPAK Random Early drop: Disabled Admin state: Enabled with 10G full-duplex Link State: Ready Link Counter: Up 0 time(s) VLAN cfg: STP cfg: Protocol: Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported QoS Profile: None configured Queue: Qp1 MinBw=0% MaxBw=100% Pri=1 Qp2 MinBw=0% MaxBw=100% Pri=2 Qp3 MinBw=0% MaxBw=100% Pri=3 Qp4 MinBw=0% MaxBw=100% Pri=4 Qp5 MinBw=0% MaxBw=100% Pri=5 Qp6 MinBw=0% MaxBw=100% Pri=6 Qp7 MinBw=0% MaxBw=100% Pri=7 Qp8 MinBw=0% MaxBw=100% Pri=8 Ingress Rate Shaping : support IQP1-8 IQP1 MinBw= 0% MaxBw=100% Pri=1 IQP2 MinBw= 0% MaxBw=100% Pri=2 IQP3 MinBw= 0% MaxBw=100% Pri=3 IQP4 MinBw= 0% MaxBw=100% Pri=4 IQP5 MinBw= 0% MaxBw=100% Pri=5 IQP6 MinBw= 0% MaxBw=100% Pri=6 IQP7 MinBw= 0% MaxBw=100% Pri=7 IQP8 MinBw= 0% MaxBw=100% Pri=8 Ingress IPTOS: Disabled Egress IPTOS: Replacement disabled Egress 802.1p: Replacement disabled Smart Redundancy: Unsupported VLANs monitored for stats: Unsupported Software redundant port: Unsupported jitter-tolerance: Unsupported

Unsupported

Following is sample output of this command for a BlackDiamond 10K switch 1 Gbps port:
Port: 2:1 Virtual-router: VR-Default Type: SX Random Early drop: Disabled Admin state: Enabled with auto-speed sensing Link State: Ready

auto-duplex

306

ExtremeWare XOS 11.3 Concepts Guide

Verifying QoS Configuration and Performance


Link Counter: Up 0 time(s) VLAN cfg: Name: Default, Internal Tag = 1, MAC-limit = No-limit STP cfg: s0(disable), Tag=(none), Mode=802.1D, State=FORWARDING Protocol: Name: Default Protocol: ANY Trunking: Load sharing is not enabled. EDP: Enabled DLCS: Unsupported lbDetect: Unsupported Learning: Enabled Flooding: Enabled Jumbo: Disabled BG QoS monitor: Unsupported QoS Profile: None configured Queue: Qp1 MinBw=0% MaxBw=100% Pri=1 Qp2 MinBw=0% MaxBw=100% Pri=2 Qp3 MinBw=0% MaxBw=100% Pri=3 Qp4 MinBw=0% MaxBw=100% Pri=4 Qp5 MinBw=0% MaxBw=100% Pri=5 Qp6 MinBw=0% MaxBw=100% Pri=6 Qp7 MinBw=0% MaxBw=100% Pri=7 Qp8 MinBw=0% MaxBw=100% Pri=8 Ingress Rate Shaping : support IQP1-2 IQP1 MinBw= 0% MaxBw=100% Pri=1 IQP2 MinBw= 0% MaxBw=100% Pri=2 Ingress IPTOS: Disabled Egress IPTOS: Replacement disabled Egress 802.1p: Replacement disabled Smart Redundancy: Unsupported VLANs monitored for stats: Unsupported Software redundant port: Unsupported jitter-tolerance: Unsupported Match all protocols.

Unsupported

NOTE
To ensure that you display the QoS information, you must use the detail variable.

Verifying QoS Configuration and Performance


You can display a variety of QoS measures using the CLI.

Monitoring PerformanceBlackDiamond 10K Switch Only


NOTE
This command is not supported on the BlackDiamond 8800 family of switches or on the Summit X450 switch.

ExtremeWare XOS 11.3 Concepts Guide

307

Quality of Service After you have created QoS policies that manage the traffic through the switch, you can use the QoS monitor on the BlackDiamond 10K switch to determine whether the application performance meets your expectations. QoS features performance monitoring with a snapshot display of the monitored ports. To view switch performance per port, use the following command:
show ports <port_list> qosmonitor {ingress | egress} {no-refresh}

NOTE
You must specify ingress to view the ingress rate-shaping performance. By default, this command displays the egress performance.

Displaying QoS Profile Information


You can also verify the QoS configuration in place. Refer to Verifying Physical and Logical Groupings on page 304 for additional information on displaying QoS information for each port.

Displaying QoS Profile Information on the BlackDiamond 8800 Family of Switches and Summit X450 Switch Only
To display QoS information on the BlackDiamond 8800 family of switches and the Summit X450 switch, use the following command:
show qosprofile

Displayed information includes:


QoS profiles configured Weight Maximum buffer percent

Displaying QoS Profile Information on the BlackDiamond 10K Switch Only


To display QoS information on the BlackDiamond 10K switch, use the following command:
show qosprofile {ingress | egress} {ports [ all | <port_list>]}

Displayed information includes:


QoS profile name Minimum bandwidth Maximum bandwidth Priority

308

ExtremeWare XOS 11.3 Concepts Guide

Guidelines for Configuring QoS

Guidelines for Configuring QoS


The following are useful guidelines for configuring QoS:

If you are using DiffServ for QoS parameters, Extreme Networks recommends that you also configure 802.1p or port-based QoS parameters to ensure that high-priority traffic is not dropped prior to reaching the Master Switch Module (MSM) on modular switches. The command to replace the 802.1p or DiffServ value affects only those traffic groupings based on explicit packet class of service and physical/logical groupings.

Egress Traffic Rate LimitingBlackDiamond 8800 Family of Switches and Summit X450 Switch Only
You can configure the maximum egress traffic allowed per port by specifying the committed rate, or you can allow the egress traffic to pass an unlimited flow. You can limit egress traffic on a 1 Gbps port in increments of 64 Kbps; on a 10 Gbps port, you can limit egress traffic in increments of 1 Mbps. Optionally, you can also configure a maximum burst size, which is higher than the limit, allowed to egress the specified port(s) for a burst, or short duration. The default behavior is to have no limit on the egress traffic per port. To view the configured egress port rate-limiting behavior, issue the following command:
show ports {mgmt | <port_list>} information {detail}

You must use the detail parameter to display the Egress Port Rate configuration and, if configured, the Max Burst size. Refer to Displaying Port Configuration Information for more information on the show ports information command. You can also display this information using the following command:
show configuration vlan

The following is sample output from the show configuration vlan command for configured egress rate limiting:
# Module vlan configuration. # create virtual-router "VR-Default" configure virtual-router VR-Default add ports 3:1-48 create vlan "Default" configure vlan Default tag 1 config port 3:1 rate-limit egress 128 Kbps max-burst-size 200 Kb config port 3:2 rate-limit egress 128 Kbps config port 3:10 rate-limit egress 73 Kbps max-burst-size 128 Kb configure vlan Default add ports 3:1-48 untagged

NOTE
Refer to Chapter 13 for more information on limiting broadcast, multicast, or unknown MAC traffic ingressing the port.

ExtremeWare XOS 11.3 Concepts Guide

309

Quality of Service

Bi-Directional Rate ShapingBlackDiamond 10K Switch Only


NOTE
If you are working with the BlackDiamond 8800 family of switches or the Summit X450 switch, refer to [ACL CHAP} for information on metering the ingressing traffic.

With software version 11.0, you can configure and display bi-directional rate shaping parameters. on the BlackDiamond 10K switch. Bi-directional rate shaping allows you to manage bandwidth on Layer 2 and Layer 3 traffic flowing to each port on the switch and from there to the backplane. You can configure up to 8 ingress queues, which send traffic to the backplane, per physical port on the I/O module. By defining minimum and maximum bandwidth for each queue, you define committed and peak information rates for each queue. You can define different priorities for each queue for each port. Rate shaping on the ingress port allows the switch to enforce how much traffic from a particular port can ingress to the system. Bi-directional rate shaping on the BlackDiamond 10K switch controls the traffic from the ingress ports to the backplane and provides guaranteed minimum rates. The number of queues from the ingress port to the backplane differs between I/O modules. The 1 Gbps I/O module has 2 queues from the ingress port to the backplane, and the 10 Gbps I/O module has 8 queues from the ingress port to the backplane. You set minimum bandwidth, maximum bandwidth, and priority for each queue for each port. Use prioritization when two or more hardware queues on the same physical port are contending for transmission, only after their respective bandwidth management parameters have been satisfied. Once the priorities are satisfied, the switch uses a round-robin system to empty the queues to the backplane. Table 47 displays the mapping of the ingress queues and the priority value for each I/O module.

Table 47: Ingress queue mapping for I/O modules on the BlackDiamond 10K switch
I/O module 1 Gbps module 10 Gbps module Ingress queues IQP1 IQP2 IQP1 IQP2 IQP3 IQP4 IQP5 IQP61 IQP7 IQP8 Priority value 1 to 4 5 to 8 1 2 3 4 5 6 7 8

Using bi-directional rate shaping, excess traffic is discarded at the I/O module and does not traverse to the backplane. You view statistics on the discarded traffic using the show ports qosmonitor or show ports information command. The 802.1p value is mapped to the ingress queue. For untagged ports, use port- or VLAN-based QoS to map traffic to the ingress queue.

310

ExtremeWare XOS 11.3 Concepts Guide

Bi-Directional Rate ShapingBlackDiamond 10K Switch Only

Bandwidth Settings
You apply ingress QoS profile (IQP or rate shaping) values on the BlackDiamond 10K switch as either a percentage of bandwidth or as an absolute value in Kbps or Mbps. IQP bandwidth settings are in turn applied to queues on physical ports. The impact of the bandwidth setting is determined by the port speed (1 or 10 Gbps). NOTE
You may see slightly different bandwidths because the switch supports granularity down to 62.5 Kbps.

Maximum Bandwidth Settings


The maximum bandwidth settings determine the port bandwidth available to each of the ingress port queues.

Minimum Bandwidth Settings


The minimum bandwidth settings, or maximum committed rate settings, determine the port bandwidth reserved for each of the ingress port queues. Table 48 displays the maximum committed rates available for each port on each BlackDiamond 10K switch I/O module.

Table 48: Maximum committed rates per port for I/O module on the BlackDiamond 10K switch
I/O module 1 Gbps module 10 Gbps module MSM configuration Single MSM Dual MSM Single MSM Dual MSM Maximum committed rate 200 Mbps 400 Mbps 2 Gbps 4 Gbps

Please note that these maximum committed rates vary with the number of active ports on each I/O module. The rates shown in Table 48 are what you can expect when you all running all ports at traffic level. If you are using fewer ports, you will have higher committed rates available for each port. And, the maximum committed rate is reached when you are running traffic on only one port.

NOTE
Cumulative percentages of minimum bandwidth of the queues on a given port should not exceed 100%

If you choose a setting not listed in the tables, the setting is rounded up to the next value. If the actual bandwidth used is below the minimum bandwidth, the additional bandwidth is not available for other queues on that physical port.

Configuring Bi-Directional Rate Shaping


The maximum bandwidth or rate defined in the BlackDiamond 10K switch ingress QoS profile defines the rate limit for ingress traffic on rate-shaped ports. You set minimum and maximum rates for each

ExtremeWare XOS 11.3 Concepts Guide

311

Quality of Service port on the ingress port, using either percentage of total bandwidth or absolute values for committed and peak rates in Kbps or Mbps. You also set the priority level for each queue. To define rate shaping on a port, you assign a minimum and maximum bandwidth or rate plus a priority value to each queue on the ingress port (see Table 47 for the number of queues available to each port on the I/O module). Use the following command to define rate shaping:
configure qosprofile ingress <iqp> [{committed_rate <committed_bps> [k | m]} {maxbw <maxbw_number>} {minbw <minbw_number>} {peak_rate <peak_bps> [k | m} {priority [<priority> | <priority_number]}] ports [<port_list> | all]

If you choose to use committed rate and peak rate values, be aware of the interactions between the values and the command line interface (CLI) management system. You can enter any integer from 0 in the CLI; however, functionally the switch operates only in multiples of 62.5 Kbps. Also note that the CLI system does not accept decimals. Rate shaping is disabled by default on all ports; the system does use existing 802.1p, port, and VLAN values to assign packets to the ingress queue. The rate shaping function is used to assign specific priorities by absolute rates or percentages of the bandwidth. To enable this rate shaping feature, use the configuration command. To disable the rate shaping, use the following command:
unconfigure qosprofile ingress ports all

To display the parameters for rate shaping (the values for the IQPs), use the following commands:
show qosprofile {ingress | egress} {ports [ all | <port_list>]} show ports {mgmt | <port_list>} information {detail}

Additionally, you can monitor the performance on the BlackDiamond 10K switch by using the following command:
show ports <port_list> qosmonitor {ingress | egress} {no-refresh}

NOTE
You must specify ingress to view ingress rate shaping performance.

312

ExtremeWare XOS 11.3 Concepts Guide

16 Security
This chapter describes the following topics:

Security Overview on page 313 Safe Defaults Mode on page 314 MAC Address Security on page 315 Denial of Service Protection on page 320 Authenticating Users Using RADIUS or TACACS+ on page 322 Secure Shell 2 on page 335 Secure Socket Layer on page 339

Security Overview
Security is a term that covers several different aspects of network use and operation. One general type of security is control of the devices or users that can access the network. Ways of doing this include authenticating the user at the point of logging in. You can also control access by defining limits on certain types of traffic. Another general type of security operates to protect the operation of the switch itself. Security measures in this category include routing policies that can limit the visibility of parts of the network or denial of service protection that prevents the CPU from being overloaded. Finally, management functions for the switch can be protected from unauthorized use. This type of protection uses various types of user authentication. ExtremeWare XOS 11.3 introduces enhanced security features designed to protect, rapidly detect, and correct anomalies in your network. Extreme Networks products incorporate a number of features designed to enhance the security of your network while resolving issues with minimal network disruption. No one feature can ensure security, but by using a number of features in concert, you can substantially improve the security of your network. The following list provides a brief overview of some of the available security features:

Access Control ListsAccess Control Lists (ACLs) are policy files used by the ACL application to perform packet filtering and forwarding decisions on incoming traffic and packets. Each packet arriving on an ingress port is compared to the ACL applied to that port and is either permitted or denied. For more information about using ACLs to control and limit network access, see Chapter 13, Access Lists (ACLs).

CLEAR-FlowCLEAR-Flow is a security rules engine available only on the BlackDiamond 10K switch. CLEAR-Flow inspects Layer 2 and Layer 3 packets, isolates suspicious traffic, and enforces policy-based mitigation actions. Policy-based mitigation actions include the switch taking an immediate, pre-determined action or sending a copy of the traffic off-switch for analysis. Working together, CLEAR-Flow and Sentriant provide a rapid response to network threats. For off-switch analysis, CLEAR-Flow sends the suspicious traffic to Sentriant and Sentriant stops the threats. For more information about CLEAR-Flow, see Chapter 18, CLEAR-Flow. For more information about Sentriant, contact your Extreme Networks representative.

ExtremeWare XOS 11.3 Concepts Guide

313

Security

Denial of Service ProtectionDenial of Service (DoS) protection is a dynamic response mechanism used by the switch to prevent critical network or computing resources from being overwhelmed and rendered inoperative. In essence, DoS protection protects the switch, CPU, and memory from attacks and attempts to characterize the attack (or problem) and filter out the offending traffic so that other functions can continue. If the switch determines it is under attack, the switch reviews the packets in the input buffer and assembles ACLs that automatically stop the offending packets from reaching the CPU. For increased security, you can turn on DoS protection and establish CLEAR-Flow rules at the same time. For more information about DoS attacks and DoS protection, see Denial of Service Protection on page 320. For more information about CLEAR-Flow, see Chapter 18, CLEAR-Flow.

Network LoginNetwork login controls the admission of user packets and access rights thereby preventing unauthorized access to the network. Network login is controlled on a per port basis. When network login is enabled on a port in a VLAN, that port does not forward any packets until authentication takes place. Network login is capable of three types of authentication: web-based, MAC-based, and 802.1x. For more information about network login, see Chapter 17, Network Login. Policy FilesPolicy files are text files that contain a series of rule entries describing match conditions and actions to take. Policy files are used by both routing protocol applications (routing policies) and the ACL application (ACLs). For more information about policy files, see Chapter 12, Policy Manager. Routing PoliciesRouting policies are policy files used by routing protocol applications to control the advertisement, reception, and use of routing information by the switch. By using policies, a set of routes can be selectively permitted or denied based on their attributes for advertisements in the routing domain. Routing policies can be used to hide entire networks or to trust only specific sources for routes or ranges of routes. For more information about using routing policies to control and limit network access, see Chapter 14, Routing Policies.

SentriantSentriant is an external security appliance used by the BlackDiamond 10K switch to detect and defend against threats without interfering with network traffic. Sentriant can actively engage, determine, and terminate malicious behavior occurring in your network. Sentriant and CLEAR-Flow provide a rapid response to network threats. Sentriant can add to or modify the BlackDiamond 10K switchs CLEAR-Flow rules and ACLs in real-time to inspect additional traffic or change inspection thresholds. For more information about Sentriant, contact your Extreme Networks representative. For more information about CLEAR-Flow, see Chapter 18, CLEAR-Flow.

sFlowsFlow is a technology designed to monitor network traffic by using a statistical sampling of packets received on each port. sFlow also uses IP headers to gather information about the network. By gathering statistics about the network, sFlow becomes an early warning system notifying you when there is a spike in traffic activity. Upon analysis, common response mechanisms include applying an ACL, changing Quality of Service (QoS) parameters, or modifying VLAN settings. For more information about sFlow, see the section Using sFlow in Chapter 8, Status Monitoring and Statistics.

Safe Defaults Mode


Beginning with ExtremeWare XOS 11.2, when you set up your switch for the first time, you must connect to the console port to access the switch. After logging in to the switch, you enter safe defaults

314

ExtremeWare XOS 11.3 Concepts Guide

MAC Address Security mode. Although SNMP, Telnet, and switch ports are enabled by default, the script prompts you to confirm those settings. By answering N (No) to each question, you keep the default settings.
Would you like to disable Telnet? [y/N]: No Would you like to disable SNMP [y/N]: No Would you like unconfigured ports to be turned off by default [y/N]: No

In addition, if you keep the default settings for SNMP and Telnet, the switch returns the following interactive script:
Since you have chosen less secure management methods, please remember to increase the security of your network by taking the following actions: * change your admin password * change your SNMP public and private strings * consider using SNMPv3 to secure network management traffic

For more detailed information about safe defaults mode, see Safe Defaults Setup Method on page 47.

MAC Address Security


The switch maintains a database of all media access control (MAC) addresses received on all of its ports. The switch uses the information in this database to decide whether a frame should be forwarded or filtered. MAC address security allows you to control the way the Forwarding Database (FDB) is learned and populated. For more information about the FDB, see Chapter 11, Forwarding Database. The following section Limiting Dynamic MAC Addresses describes how MAC address security allows you to limit the number of dynamically-learned MAC addresses allowed per virtual port. The section MAC Address Lock Down on page 317 describes how you can also lock the FDB entries for a virtual port, so that the current entries will not change, and no additional addresses can be learned on the port.

NOTE
You can either limit dynamic MAC FDB entries or lock down the current MAC FDB entries, but not both.

Using ACLS, you can also prioritize or stop packet flows based on the source MAC address of the ingress virtual LAN (VLAN) or the destination MAC address of the egress VLAN. For more information about ACL policies, see Chapter 13, Access Lists (ACLs). Another method of enhancing security, depending on your network configuration, is to disable Layer 2 flooding. For more information about enabling and disabling Layer 2 flooding, see the section, Disabling Egress Flooding in Chapter 11, Forwarding Database.

Limiting Dynamic MAC Addresses


You can set a predefined limit on the number of dynamic MAC addresses that can participate in the network. After the FDB reaches the MAC limit, all new source MAC addresses are blackholed at both the ingress and egress points. These dynamic blackhole entries prevent the MAC addresses from learning and responding to Internet Control Message Protocol (ICMP) and address resolution protocol (ARP) packets.

ExtremeWare XOS 11.3 Concepts Guide

315

Security

NOTE
Blackhole FDB entries added due to MAC security violations on the BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch are removed after each FDB aging period regardless of whether the MAC addresses in question are still sending traffic. If the MAC addresses are still sending traffic, the blackhole entries will be re-added after they have been deleted.

Configuring Limit Learning


To limit the number of dynamic MAC addresses that can participate in the network, use the limitlearning option in following command:
configure ports <portlist> vlan <vlan name> [limit-learning <number> | lock-learning | unlimited-learning | unlock-learning]

This command specifies the number of dynamically-learned MAC entries allowed for these ports in this VLAN. The range is 0 to 500,000 addresses. When the learned limit is reached, all new source MAC addresses are blackholed at the ingress and egress points. This prevents these MAC addresses from learning and responding to ICMP and ARP packets. Dynamically learned entries still get aged and can be cleared. If entries are cleared or aged out after the learning limit has been reached, new entries will then be able to be learned until the limit is reached again. Permanent static and permanent dynamic entries can still be added and deleted using the create fdbentry and disable flooding port commands. These override any dynamically learned entries. For ports that have a learning limit in place, the following traffic still flows to the port:

Packets destined for permanent MAC addresses and other non-blackholed MAC addresses Broadcast traffic EDP traffic

Traffic from the permanent MAC and any other non-blackholed MAC addresses still flows from the virtual port. To remove the learning limit, use the unlimited-learning option from the following command:
configure ports <portlist> vlan <vlan name> [limit-learning <number> | lock-learning | unlimited-learning | unlock-learning]

Displaying Limit Learning Information


To verify the configuration, use the following commands:
show vlan <vlan name> security

This command displays the MAC security information for the specified VLAN.
show ports {mgmt | <portlist>} info {detail}

316

ExtremeWare XOS 11.3 Concepts Guide

MAC Address Security This command displays detailed information, including MAC security information, for the specified port.

Limiting MAC Addresses with ESRP Enabled


If you configure a MAC address limit on VLANS that participate in an Extreme Standby Router Protocol (ESRP) domain, you should add an additional back-to-back link (that has no MAC address limit on these ports) between the ESRP-enabled switches. Doing so prevents ESRP protocol data units (PDUs) from being dropped due to MAC address limit settings. Figure 16 is an example of configuring a MAC address limit on a VLAN participating in an ESRP domain.

Figure 16: MAC address limits and VLANs participating in ESRP

ESRP vlan S1

10.1.2.1

20.1.1.1

S2 S4
10.1.2.2

20.1.2.2 192.10.1.1

10.1.2.100

192.10.1.100

S3
10.1.2.1 30.1.1.1
EX_036

30.1.1.2

In Figure 16, S2 and S3 are ESRP-enabled switches, while S1 is an ESRP-aware (regular Layer 2) switch. Configuring a MAC address limit on all S1 ports might prevent ESRP communication between S2 and S3. To resolve this, you should add a back-to-back link between S2 and S3. This link is not needed if MAC address limiting is configured only on S2 and S3, but not on S1.

MAC Address Lock Down


In contrast to limiting learning on virtual ports, you can lock down the existing dynamic FDB entries and prevent any additional learning using the lock-learning option from the following command:
configure ports <portlist> vlan <vlan name> [limit-learning <number> | lock-learning | unlimited-learning | unlock-learning]

This command causes all dynamic FDB entries associated with the specified VLAN and ports to be converted to locked static entries. It also sets the learning limit to zero, so that no new entries can be learned. All new source MAC addresses are blackholed.

ExtremeWare XOS 11.3 Concepts Guide

317

Security

NOTE
Blackhole FDB entries added due to MAC security violations on the BlackDiamond 8800 family of switches and the Summit X450 switch are removed after each FDB aging period regardless of whether the MAC addresses in question are still sending traffic. If the MAC addresses are still sending traffic, the blackhole entries will be re-added after they have been deleted.

Locked entries do not get aged, but can be deleted like a regular permanent entry. For ports that have lock-down in effect, the following traffic still flows to the port:

Packets destined for the permanent MAC and other non-blackholed MAC addresses Broadcast traffic EDP traffic

Traffic from the permanent MAC still flows from the virtual port. To remove MAC address lock down, use the unlock-learning option from the following command:
configure ports <portlist> vlan <vlan name> [limit-learning <number> | lock-learning | unlimited-learning | unlock-learning]

When you remove the lock down using the unlock-learning option, the learning-limit is reset to unlimited, and all associated entries in the FDB are flushed.

DHCP Server
Dynamic Host Configuration Protocol (DHCP) support was introduced into ExtremeWare XOS in release 11.0. In simple terms, a DHCP server dynamically manages and allocates IP addresses to clients. When a client accesses the network, the DHCP server provides an IP address to that client. The client is not required to receive the same IP address each time it accesses the network. A DHCP server with limited configuration capabilities is included in the switch to provide IP addresses to clients. This section describes the following topics:

Enabling and Disabling DHCP on page 318 Configuring the DHCP Server on page 319 Displaying DHCP Information on page 319

Enabling and Disabling DHCP


DHCP is enabled on a per port, per VLAN basis. To enable or disable DHCP on a port in a VLAN, use one of the following commands:
enable dhcp ports <portlist> vlan <vlan_name> disable dhcp ports <portlist> vlan <vlan name>

318

ExtremeWare XOS 11.3 Concepts Guide

DHCP Server

Configuring the DHCP Server


The following commands allow you to configure the DHCP server included in the switch. The parameters available to configure include the IP address range, IP address lease, and multiple DHCP options. To configure the range of IP addresses assigned by the DHCP server, use the following command:
configure vlan <vlan_name> dhcp-address-range <ipaddress1> - <ipaddress2>

To remove the address range information, use the following command:


unconfigure vlan <vlan_name> dhcp-address-range

To set how long the IP address lease assigned by the server exists, use the following command:
configure vlan <vlan_name> dhcp-lease-timer <lease-timer>

To set the default gateway, Domain Name Servers (DNS) addresses, or Windows Internet Naming Service (WINS) server, use the following command:
configure vlan <vlan_name> dhcp-options [default-gateway | dns-server | wins-server] <ipaddress>

To remove the default gateway, DNS server addresses, and WINS server information for a particular VLAN, use the following command:
unconfigure vlan <vlan_name> dhcp-options

To remove all the DHCP information for a particular VLAN, use the following command:
unconfigure vlan <vlan_name> dhcp

You can clear the DHCP address allocation table selected entries, or all entries. You would use this command to troubleshoot IP address allocation on the VLAN. To clear entries, use the following command:
clear vlan <vlan_name> dhcp-address-allocation [[all {offered | assigned | declined | expired}] | <ipaddress>]

Displaying DHCP Information


To display the DHCP configuration, including the DHCP range, DHCP lease timer, network login lease timer, DHCP-enabled ports, IP address, MAC address, and time assigned to each end device, use the following command:
show dhcp-server {vlan <vlan_name>}

The next two commands were retained for compatibility with earlier versions of ExtremeWare. To view only the address allocation of the DHCP server on a VLAN, use the following command:
show vlan <vlan_name> dhcp-address-allocation

To view only the configuration of the DHCP server on a VLAN, use the following command:
show vlan <vlan_name> dhcp-config

ExtremeWare XOS 11.3 Concepts Guide

319

Security

Denial of Service Protection


A Denial-of-Service (DoS) attack occurs when a critical network or computing resource is overwhelmed and rendered inoperative in a way that legitimate requests for service cannot succeed. In its simplest form, a Denial of Service attack is indistinguishable from normal heavy traffic. There are some operations in any switch or router that are more costly than others, and although normal traffic is not a problem, exception traffic must be handled by the switchs CPU in software. Some packets that the switch processes in the CPU software include:

Learning new traffic (BlackDiamond 10K switch only; the BlackDiamond 8800 family of switches and the Summit X450 switch learn in hardware) Routing and control protocols including ICMP, BGP, OSPF, STP, EAPS, ESRP, and so forth Switch management traffic (switch access by Telnet, SSH, HTTP, SNMP, and so forth) Other packets directed to the switch that must be discarded by the CPU

If any one of these functions is overwhelmed, the CPU may be too busy to service other functions and switch performance will suffer. Even with very fast CPUs, there will always be ways to overwhelm the CPU with packets requiring costly processing. DoS Protection is designed to help prevent this degraded performance by attempting to characterize the problem and filter out the offending traffic so that other functions can continue. When a flood of CPU bound packets reach the switch, DoS Protection will count these packets. When the packet count nears the alert threshold, packets headers will be saved. If the threshold is reached, then these headers are analyzed, and a hardware access control list (ACL) is created to limit the flow of these packets to the CPU. This ACL will remain in place to provide relief to the CPU. Periodically, the ACL will expire, and if the attack is still occurring, it will be re-enabled. With the ACL in place, the CPU will have the cycles to process legitimate traffic and continue other services. DoS Protection will send a notification when the notify threshold is reached. You can also specify some ports as trusted ports, so that DoS protection will not be applied to those ports.

Configuring Simulated Denial of Service Protection


The conservative way to deploy DoS protection is to use the simulated mode first. In simulated mode, DoS protection is enabled, but no ACLs are generated. To enable the simulated mode, use the following command:
enable dos-protect simulated

This mode is useful to gather information about normal traffic levels on the switch. This will assist in configuring denial of service protection so that legitimate traffic is not blocked. The remainder of this section describes how to configure DoS protection, including alert thresholds, notify thresholds, ACL expiration time, and so on.

320

ExtremeWare XOS 11.3 Concepts Guide

Denial of Service Protection

Configuring Denial of Service Protection


To enable or disable DoS protection, use the following commands:
enable dos-protect disable dos-protect

After enabling DoS protection, the switch will count the packets handled by the CPU and periodically evaluate whether to send a notification and/or create an ACL to block offending traffic. You can configure a number of the values used by DoS protection if the default values are not appropriate for your situation. The values that you can configure are:

intervalHow often, in seconds, the switch evaluates the DoS counter (default: 1 second) alert thresholdThe number of packets received in an interval that will generate an ACL (default: 4000 packets) notify thresholdThe number of packets received in an interval that will generate a notice (default: 3500 packets) ACL expiration timeThe amount of time, in seconds, that the ACL will remain in place (default: 5 seconds)

To configure the interval at which the switch checks for DoS attacks, use the following command:
configure dos-protect interval <seconds>

To configure the alert threshold, use the following command:


configure dos-protect type l3-protect alert-threshold <packets>

To configure the notification threshold, use the following command:


configure dos-protect type l3-protect notify-threshold <packets>

To configure the ACL expiration time, use the following command:


configure dos-protect acl-expire <seconds>

Configuring Trusted Ports


Traffic from trusted ports will be ignored when DoS protect counts the packets to the CPU. If we know that a machine connected to a certain port on the switch is a safe "trusted" machine, and we know that we will not get a DoS attack from that machine, the port where this machine is connected to can be configured as a trusted port, even though a large amount of traffic is going through this port. To configure the trusted ports list, use the following command:
configure dos-protect trusted-ports [ports [<ports> | all] | add-ports [<ports-to-add> | all] | delete-ports [<ports-to-delete> | all] ]

Displaying DoS Protection Settings


To display the DoS protection settings, use the following command:
show dos-protect {detail}

ExtremeWare XOS 11.3 Concepts Guide

321

Security

Authenticating Users Using RADIUS or TACACS+


ExtremeWare XOS provides three methods to authenticate users who login to the switch:

RADIUS TACACS+ Local database of accounts and passwords

RADIUS, TACACS+, local database of accounts and passwords, and SSH are management access security features that control access to the management functions available on the switch. These features help ensure that any configuration changes to the switch can be done only by authorized users. The information in this section describes RADIUS and TACACS+. For a detailed description of the local database of accounts and passwords (the two levels of management accounts), see Chapter 2, Accessing the Switch. For information about SSH, see Secure Shell 2 on page 335.

RADIUS
Remote Authentication Dial In User Service (RADIUS), in RFC 2138, is a mechanism for authenticating and centrally administrating access to network nodes. The ExtremeWare XOS RADIUS implementation allows authentication for Telnet or console access to the switch. NOTE
You cannot enable RADIUS and TACACS+ at the same time.

You define a primary and secondary RADIUS server for the switch to contact. When a user attempts to log in using Telnet, HTTP, or the console, the request is relayed to the primary RADIUS server and then to the secondary RADIUS server, if the primary does not respond. If the RADIUS client is enabled, but access to the RADIUS primary and secondary server fails, the switch uses its local database for authentication. Beginning with ExtremeWare XOS 11.2, you can specify one pair of RADIUS servers for switch management and another pair for network login. The privileges assigned to the user (admin versus nonadmin) at the RADIUS server take precedence over the configuration in the local switch database. This section describes the following topics:

Configuring the RADIUS Servers on page 323 Configuring the RADIUS Timeout Value on page 323 Configuring the Shared Secret Password for RADIUS Servers on page 323 Enabling and Disabling RADIUS on page 323 Configuring RADIUS Accounting on page 324 Configuring the RADIUS Accounting Timeout Value on page 324 Configuring the Shared Secret Password for RADIUS Accounting Servers on page 324 Enabling and Disabling RADIUS Accounting on page 325

322

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+

Configuring the RADIUS Servers


To configure the RADIUS servers, use the following command:
configure radius {mgmt-access | netlogin} [primary | secondary] server [<ipaddress> | <hostname>] {<udp_port>} client-ip [<ipaddress>] {vr <vr_name>}

To configure the primary RADIUS server, specify primary. To configure the secondary RADIUS server, specify secondary. By default, switch management and network login use the same primary and secondary RADIUS servers for authentication. To specify one pair of RADIUS servers for switch management and another pair for network login, make sure to specify the mgmt-access or netlogin keywords.

Configuring the RADIUS Timeout Value


To configure the timeout if a server fails to respond, use the following command:
configure radius {mgmt-access | netlogin} timeout <seconds>

If the timeout expires, another authentication attempt will be made. After three failed attempts to authenticate, the alternate server will be used. After six failed attempts, local user authentication will be used. If you do not specify the mgmt-access or netlogin keywords, the timeout interval applies to both switch management and netlogin RADIUS servers.

Configuring the Shared Secret Password for RADIUS Servers


In addition to specifying the RADIUS server IP information, RADIUS also contains a means to verify communication between network devices and the server. The shared secret is a password configured on the network device and RADIUS server, used by each to verify communication. To configure the shared secret for RADIUS servers, use the following command:
configure radius {mgmt-access | netlogin} [primary | secondary] shared-secret {encrypted} <string>

To configure the primary RADIUS server, specify primary. To configure the secondary RADIUS server, specify secondary. If you do not specify the mgmt-access or netlogin keywords, the secret applies to both the primary or secondary switch management and netlogin RADIUS servers. Do not use the encrypted keyword to set the shared secret. The encrypted keyword is primarily for the output of the show configuration command, so the shared secret is not revealed in the command output.

Enabling and Disabling RADIUS


After server information is entered, you can start and stop RADIUS authentication as many times as necessary without needing to reconfigure server information.

ExtremeWare XOS 11.3 Concepts Guide

323

Security To enable RADIUS authentication, use the following command:


enable radius {mgmt-access | netlogin}

If you do not specify the mgmt-access or netlogin keywords, RADIUS authentication is enabled on the switch for both management and network login. To disable RADIUS authentication, use the following command:
disable radius {mgmt-access | netlogin}

If you do not specify the mgmt-access or netlogin keywords, RADIUS authentication is disabled on the switch for both management and network login.

Configuring RADIUS Accounting


Extreme Networks switches are capable of sending RADIUS accounting information. As with RADIUS authentication, you can specify two servers for receipt of accounting information. To specify RADIUS accounting servers, use the following command:
configure radius-accounting {mgmt-access | netlogin} [primary | secondary] server [<ipaddress> | <hostname>] {<tcp_port>} client-ip [<ipaddress>] {vr <vr_name>}

To configure the primary RADIUS accounting server, specify primary. To configure the secondary RADIUS accounting server, specify secondary. By default, switch management and network login use the same primary and secondary RADIUS servers for accounting. To specify one pair of RADIUS accounting servers for switch management and another pair for network login, make sure to specify the mgmt-access or netlogin keywords.

Configuring the RADIUS Accounting Timeout Value


To configure the timeout if a server fails to respond, use the following command:
configure radius-accounting {mgmt-access | netlogin} timeout <seconds>

If the timeout expires, another authentication attempt will be made. After three failed attempts to authenticate, the alternate server will be used.

Configuring the Shared Secret Password for RADIUS Accounting Servers


RADIUS accounting also uses the shared secret password mechanism to validate communication between network access devices and RADIUS accounting servers. To specify shared secret passwords for RADIUS accounting servers, use the following command:
configure radius-accounting {mgmt-access | netlogin} [primary | secondary] sharedsecret {encrypted} <string>

To configure the primary RADIUS accounting server, specify primary. To configure the secondary RADIUS accounting server, specify secondary. If you do not specify the mgmt-access or netlogin keywords, the secret applies to both the primary or secondary switch management and netlogin RADIUS accounting servers.

324

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+ Do not use the encrypted keyword to set the shared secret. The encrypted keyword is primarily for the output of the show configuration command, so the shared secret is not revealed in the command output.

Enabling and Disabling RADIUS Accounting


After you configure RADIUS accounting server information, you must enable accounting before the switch begins transmitting the information. You must enable RADIUS authentication for accounting information to be generated. You can enable and disable accounting without affecting the current state of RADIUS authentication. To enable RADIUS accounting, use the following command:
enable radius-accounting {mgmt-access | netlogin}

If you do not specify a keyword, RADIUS accounting is enabled on the switch for both management and network login. To disable RADIUS accounting, use the following command:
disable radius-accounting {mgmt-access | netlogin}

If you do not specify a keyword, RADIUS accounting is disabled on the switch for both management and network login.

Per Command Authentication Using RADIUS


You can use the RADIUS implementation to perform per command authentication. Per command authentication allows you to define several levels of user capabilities by controlling the permitted command sets based on the RADIUS user name and password. You do not need to configure any additional switch parameters to take advantage of this capability. The RADIUS server implementation automatically negotiates the per command authentication capability with the switch. For examples on per-command RADIUS configurations, see the next section.

Configuring RADIUS
You can define primary and secondary server communication information and, for each RADIUS server, the RADIUS port number to use when talking to the RADIUS server. The default port value is 1812 for authentication and 1813 for accounting. The client IP address is the IP address used by the RADIUS server for communicating back to the switch. NOTE
For information on how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

ExtremeWare XOS 11.3 Concepts Guide

325

Security

RADIUS RFC 2138 Attributes


The RADIUS RFC 2138 optional attributes supported are as follows:

User-Name User-Password Service-Type Login-IP-Host

RADIUS RFC 3580 Attributes


The RFC 3580 attributes for Netlogin 802.1x supported are as follows:

EAP-Message Message-Authenticator State Termination-Action Session-Timeout NAS-Port-Type Calling-Station-ID

Using RADIUS Servers with Extreme Networks Switches


Extreme Networks switches have two levels of user privilege:

Read-only Read-write

Because no command line interface (CLI) commands are available to modify the privilege level, access rights are determined when you log in. For a RADIUS server to identify the administrative privileges of a user, Extreme Networks switches expect a RADIUS server to transmit the Service-Type attribute in the Access-Accept packet, after successfully authenticating the user. Extreme Networks switches grant a RADIUS-authenticated user read-write privilege if a Service-Type value of 6 is transmitted as part of the Access-Accept message from the RADIUS server. Other ServiceType values or no value, result in the switch granting read-only access to the user. Different implementations of RADIUS handle attribute transmission differently. You should consult the documentation for your specific implementation of RADIUS when you configure users for read-write access.

Extreme RADIUS
Extreme Networks provides its users, free of charge, a radius server based on Merit RADIUS. Extreme RADIUS provides per-command authentication capabilities in addition to the standard set of radius features. Source code for Extreme RADIUS can be obtained from the Extreme Networks Technical Assistance Center and has been tested on Red Hat Linux. When Extreme RADIUS is up and running, the two most commonly changed files will be users and profiles. The users file contains entries specifying login names and the profiles used for per-command authentication after they have logged in. Sending a HUP signal to the RADIUS process is sufficient to get changes in the users file to take place. Extreme RADIUS uses the file named profiles to specify

326

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+ command lists that are either permitted or denied to a user based on their login identity. Changes to the profiles file require the RADIUS server to be shutdown and restarted. Sending a HUP signal to the RADIUS process is not enough to force changes to the profiles file to take effect. When you create command profiles, you can use an asterisk to indicate any possible ending to any particular command. The asterisk cannot be used as the beginning of a command. Reserved words for commands are matched exactly to those in the profiles file. Due to the exact match, it is not enough to simply enter sh for show in the profiles file, the complete word must be used. Commands can still be entered in the switch in partial format. When you use per-command authentication, you must ensure that communication between the switch(es) and radius server(s) is not lost. If the RADIUS server crashes while users are logged in, they will have full administrative access to the switch until they log out. Using two RADIUS servers and enabling idle timeouts on all switches will greatly reduce the chance of a user gaining elevated access due to RADIUS server problems.

Cistron RADIUS
Cistron RADIUS is a popular server, distributed under GPL. Cistron RADIUS can be found at: http://www.miquels.cistron.nl/radius/ When you configure the Cistron server for use with Extreme switches, you must pay close attention to the users file setup. The Cistron RADIUS dictionary associates the word Administrative-User with Service-Type value 6, and expects the Service-Type entry to appear alone on one line with a leading tab character. The following is a user file example for read-write access: adminuser Auth-Type = System Service-Type = Administrative-User, Filter-Id = unlim

RSA Ace
For users of their SecureID product, RSA offers RADIUS capability as part of their ACE server software. With some versions of ACE, the RADIUS shared-secret is incorrectly sent to the switch resulting in an inability to authenticate. As a work around, do not configure a shared-secret for RADIUS accounting and authentication servers on the switch.

Limiting Max-Concurrent Sessions with Funk Softwares Steel Belted Radius


For users who have Funk Softwares Steel Belted Radius (SBR) server, it is possible to limit the number of concurrent login sessions using the same user account. This feature allows the use of shared user accounts, but limits the number of simultaneous logins to a defined value. Using this feature requires Funk Software Steel-Belted-Radius for Radius Authentication & Accounting.

ExtremeWare XOS 11.3 Concepts Guide

327

Security Complete the following two steps to limit the maximum concurrent login sessions under the same user account: 1 Configure Radius and Radius-Accounting on the switch. The Radius and Radius-Accounting servers used for this feature must reside on the same physical Radius server. Standard Radius and Radius-Accounting configuration is required as described earlier in this chapter. 2 Modify the Funk SBR vendor.ini file and user accounts. To configure the Funk SBR server, the file vendor.ini must be modified to change the Extreme Networks configuration value of ignore-ports to yes as shown in the example below:
vendor-product dictionary ignore-ports port-number-usage help-id = = = = = Extreme Networks Extreme yes per-port-type 2000

After modifying the vendor.ini file, the desired user accounts must be configured for the MaxConcurrent connections. Using the SBR Administrator application, enable the check box for MaxConcurrent connections and fill in the desired number of maximum sessions.

RADIUS Server Configuration Example (Merit)


Many implementations of RADIUS server use the publicly available Merit AAA server application. To get a copy, search for the server on the website at: www.merit.edu Included below are excerpts from relevant portions of a sample Merit RADIUS server implementation. The example shows excerpts from the client and user configuration files. The client configuration file (ClientCfg.txt) defines the authorized source machine, source name, and access level. The user configuration file (users) defines username, password, and service type information.
ClientCfg.txt #Client Name #---------------#10.1.2.3:256 #pm1 #pm2 #merit.edu/homeless #homeless #xyz.merit.edu #anyoldthing:1234 10.202.1.3 10.203.1.41 10.203.1.42 10.0.52.14 users user Password Filter-Id = admin Password Filter-Id = eric = "" "unlim" = "", Service-Type = Administrative "unlim" Key [type] [version] --------------- -------------- --------test type = nas v2 %^$%#*(&!(*&)+ type=nas :-):-(;^):-}! type nas hmoemreilte.ses testing type proxy v1 moretesting type=Ascend:NAS v1 whoknows? type=NAS+RAD_RFC+ACCT_RFC andrew-linux type=nas eric type=nas eric type=nas samf type=nas [prefix] -------pfx pm1. pm2.

Password = "", Service-Type = Administrative

328

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+


Filter-Id = "unlim" albert Password = "password", Service-Type = Administrative Filter-Id = "unlim" samuel Password = "password", Service-Type = Administrative Filter-Id = "unlim"

RADIUS Per-Command Configuration Example


Building on this example configuration, you can use RADIUS to perform per-command authentication to differentiate user capabilities. To do so, use the Extreme-modified RADIUS Merit software that is available from the Extreme Networks by contacting Extreme Networks technical support. The software is available in compiled format for Solaris or Linux operating systems, as well as in source code format. For all clients that use RADIUS per-command authentication, you must add the following type to the client file:
type:extreme:nas + RAD_RFC + ACCT_RFC

Within the users configuration file, additional keywords are available for Profile-Name and ExtremeCLI-Authorization. To use per-command authentication, enable the CLI authorization function and indicate a profile name for that user. If authorization is enabled without specifying a valid profile, the user is unable to perform any commands. Next, define the desired profiles in an ASCII configuration file called profiles. This file contains named profiles of exact or partial strings of CLI commands. A named profile is linked with a user through the users file. A profile with the permit on keywords allows use of only the listed commands. A profile with the deny keyword allows use of all commands except the listed commands. CLI commands can be defined easily in a hierarchal manner by using an asterisk (*) to indicate any possible subsequent entry. The parser performs exact string matches on other text to validate commands. Commands are separated by a comma (,) or newline. Looking at the following example content in profiles for the profile named PROFILE1, which uses the deny keyword, the following attributes are associated with the user of this profile:

Cannot use any command starting with enable. Cannot issue the disable ipforwarding command. Cannot issue a show switch command. Can perform all other commands.

We know from the users file that this applies to the users albert and lulu. We also know that eric is able to log in, but is unable to perform any commands, because he has no valid profile assigned. In PROFILE2, a user associated with this profile can use any enable command, the clear counters command and the show management command, but can perform no other functions on the switch. We also know from the users file that gerald has these capabilities. The following lists the contents of the file users with support for per-command authentication:
user Password = "" Filter-Id = "unlim" Password = "", Service-Type = Administrative Filter-Id = "unlim"

admin

ExtremeWare XOS 11.3 Concepts Guide

329

Security

eric

Password = "", Service-Type = Administrative, Profile-Name = "" Filter-Id = "unlim" Extreme:Extreme-CLI-Authorization = Enabled

albert Password = "", Service-Type = Administrative, Profile-Name = "Profile1" Filter-Id = "unlim" Extreme:Extreme-CLI-Authorization = Enabled lulu Password = "", Service-Type = Administrative, Profile-Name = "Profile1" Filter-Id = "unlim" Extreme:Extreme-CLI-Authorization = Enabled gerald Password = "", Service-Type = Administrative, Profile-Name "Profile2" Filter-Id = "unlim" Extreme:Extreme-CLI-Authorization = Enabled

Contents of the file profiles:


PROFILE1 deny { enable *, disable ipforwarding show switch } PROFILE2 { enable *, clear counters show management } PROFILE3 deny { create vlan *, configure iproute *, disable *, show fdb delete *, configure rip add }

TACACS+
Terminal Access Controller Access Control System Plus (TACACS+) is a mechanism for providing authentication, authorization, and accounting on a centralized server, similar in function to RADIUS. The ExtremeWare XOS version of TACACS+ is used to authenticate prospective users who are attempting to administer the switch. TACACS+ is used to communicate between the switch and an authentication database. NOTE
You cannot use RADIUS and TACACS+ at the same time.

You can configure two TACACS+ servers, specifying the primary server address, secondary server address, and TCP port number to be used for TACACS+ sessions.

330

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+ This section describes the following topics:

Configuring the TACACS+ Servers on page 331 Configuring the TACACS+ Timeout Value on page 331 Configuring the Shared Secret Password for TACACS+ Servers on page 331 Enabling and Disabling TACACS+ on page 332 TACACS+ Configuration Example on page 332 Configuring TACACS+ Accounting on page 333 Configuring the TACACS+ Accounting Timeout Value on page 333 Configuring the Shared Secret Password for TACACS+ Accounting Servers on page 333 Enabling and Disabling TACACS+ Accounting on page 334 TACACS+ Accounting Configuration Example on page 334

Configuring the TACACS+ Servers


To configure the TACACS+ servers, use the following command:
configure tacacs [primary | secondary] server [<ipaddress> | <hostname>] {<tcp_port>} client-ip <ipaddress> {vr <vr_name>}

To configure the primary TACACS+ server, specify primary. To configure the secondary TACACS+ server, specify secondary.

Configuring the TACACS+ Timeout Value


To configure the timeout if a server fails to respond, use the following command:
configure tacacs timeout <seconds>

To detect and recover from a TACACS+ server failure when the timeout has expired, the switch makes one authentication attempt before trying the next designated TACACS+ server or reverting to the local database for authentication. In the event that the switch still has IP connectivity to the TACACS+ server, but a TCP session cannot be established, (such as a failed TACACS+ daemon on the server), fail over happens immediately regardless of the configured timeout value. For example, if the timeout value is set for 3 seconds (the default value), it will take 3 seconds to fail over from the primary TACACS+ server to the secondary TACACS+ server. If both the primary and the secondary servers fail or are unavailable, it takes approximately 6 seconds to revert to the local database for authentication.

Configuring the Shared Secret Password for TACACS+ Servers


In addition to specifying the TACACS+ server IP information, TACACS+ also contains a means to verify communication between network devices and the server. The shared secret is a password configured on the network device and TACACS+ server, used by each to verify communication. To configure the shared secret for TACACS+ servers, use the following command:
configure tacacs [primary | secondary] shared-secret {encrypted} <string>

To configure the primary TACACS+ server, specify primary. To configure the secondary TACACS+ server, specify secondary.

ExtremeWare XOS 11.3 Concepts Guide

331

Security Do not use the encrypted keyword to set the shared secret. The encrypted keyword is primarily for the output of the show configuration command, so the shared secret is not revealed in the command output.

Enabling and Disabling TACACS+


After server information is entered, you can start and stop TACACS+ authentication as many times as necessary without needing to reconfigure server information. To enable TACACS+ authentication, use the following command:
enable tacacs

To disable TACACS+ authentication, use the following command:


disable tacacs

TACACS+ Configuration Example


This section provides a sample TACACS+ server configuration. The following example:

Configures the primary TACACS+ server Configures the shared secret for the primary TACACS+ server Configures the secondary TACACS+ server Configures the shared secret for the secondary TACACS+ server Enables TACACS+ on the switch

All other settings use the default settings as described earlier in this section or in the ExtremeWare XOS Command Reference Guide.
configure tacacs configure tacacs configure tacacs configure tacacs enable tacacs primary server 10.201.31.238 client-ip 10.201.31.85 vr "VR-Default" primary shared-secret purple secondary server 10.201.31.235 client-ip 10.201.31.85 vr "VR-Default" secondary shared-secret purple

To display the TACACS+ server settings, use the show tacacs command. The following is sample output from this command:
TACACS+: enabled TACACS+ Authorization: disabled TACACS+ Accounting : disabled TACACS+ Server Connect Timeout sec: 3 Primary TACACS+ Server: Server name : IP address : 10.201.31.238 Server IP Port: 49 Client address: 10.201.31.85 (VR-Default) Shared secret : purple Secondary TACACS+ Server: Server name : IP address : 10.201.31.235

332

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users Using RADIUS or TACACS+


Server IP Port: 49 Client address: 10.201.31.85 (VR-Default) Shared secret : purple TACACS+ Acct Server Connect Timeout sec: 3 Primary TACACS+ Accounting Server:Not configured Secondary TACACS+ Accounting Server:Not configured

Configuring TACACS+ Accounting


Extreme Networks switches are capable of sending TACACS+ accounting information. As with TACACS+ authentication, you can specify two servers for receipt of accounting information. To specify TACACS+ accounting servers, use the following command:
configure tacacs-accounting [primary | secondary] server [<ipaddress> | <hostname>] {<udp_port>} client-ip <ipaddress> {vr <vr_name>}

To configure the primary TACACS+ accounting server, specify primary. To configure the secondary TACACS+ accounting server, specify secondary.

Configuring the TACACS+ Accounting Timeout Value


To configure the timeout if a server fails to respond, use the following command:
configure tacacs-accounting timeout <seconds>

To detect and recover from a TACACS+ accounting server failure when the timeout has expired, the switch makes one authentication attempt before trying the next designated TACACS+ accounting server or reverting to the local database for authentication. In the event that the switch still has IP connectivity to the TACACS+ accounting server, but a TCP session cannot be established, (such as a failed TACACS+ daemon on the accounting server), fail over happens immediately regardless of the configured timeout value. For example, if the timeout value is set for 3 seconds (the default value), it takes 3 seconds to fail over from the primary TACACS+ accounting server to the secondary TACACS+ accounting server. If both the primary and the secondary servers fail or are unavailable, it takes approximately 6 seconds to revert to the local database for authentication.

Configuring the Shared Secret Password for TACACS+ Accounting Servers


TACACS+ accounting also uses the shared secret password mechanism to validate communication between network access devices and TACACS+ accounting servers. To specify shared secret passwords for TACACS+ accounting servers, use the following command:
configure tacacs-accounting [primary | secondary] shared-secret {encrypted} <string>

To configure the primary TACACS+ accounting server, specify primary. To configure the secondary TACACS+ accounting server, specify secondary. Do not use the encrypted keyword to set the shared secret. The encrypted keyword is primarily for the output of the show configuration command, so the shared secret is not revealed in the command output.

ExtremeWare XOS 11.3 Concepts Guide

333

Security

Enabling and Disabling TACACS+ Accounting


After you configure TACACS+ accounting server information, you must enable accounting before the switch begins transmitting the information. You must enable TACACS+ authentication for accounting information to be generated. You can enable and disable accounting without affecting the current state of TACACS+ authentication. To enable TACACS+ accounting, use the following command:
enable tacacs-accounting

To disable TACACS+ accounting, use the following command:


disable tacacs-accounting

TACACS+ Accounting Configuration Example


This section provides a sample TACACS+ accounting server configuration. The following example:

Configures the primary TACACS+ accounting server Configures the shared secret for the primary TACACS+ accounting server Configures the secondary TACACS+ accounting server Configures the shared secret for the secondary TACACS+ accounting server Enables TACACS+ accounting on the switch

All other settings use the default settings as described earlier in this section or in the ExtremeWare XOS Command Reference Guide.
configure tacacs-accounting primary server 10.201.31.238 client-ip 10.201.31.85 vr "VR-Default" configure tacacs-accounting primary shared-secret purple configure tacacs-accounting secondary server 10.201.31.235 client-ip 10.201.31.85 vr "VR-Default" config tacacs-accounting secondary shared-secret purple enable tacacs-accounting

To display the TACACS+ accounting server settings, use the show tacacs or the show tacacsaccounting command. The following is sample output from the show tacacs command:
TACACS+: enabled TACACS+ Authorization: enabled TACACS+ Accounting : enabled TACACS+ Server Connect Timeout sec: 3 Primary TACACS+ Server: Server name : IP address : 10.201.31.238 Server IP Port: 49 Client address: 10.201.31.85 (VR-Default) Shared secret : purple Secondary TACACS+ Server: Server name : IP address : 10.201.31.235 Server IP Port: 49

334

ExtremeWare XOS 11.3 Concepts Guide

Secure Shell 2
Client address: 10.201.31.85 (VR-Default) Shared secret : purple TACACS+ Acct Server Connect Timeout sec: 3 Primary TACACS+ Accounting Server: Server name : IP address : 10.201.31.238 Server IP Port: 49 Client address: 10.201.31.85 (VR-Default) Shared secret : purple Secondary TACACS+ Accounting Server: Server name : IP address : 10.201.31.235 Server IP Port: 49 Client address: 10.201.31.85 (VR-Default) Shared secret : purple

Secure Shell 2
Secure Shell 2 (SSH2) is a feature of ExtremeWare XOS that allows you to encrypt session data between a network administrator using SSH2 client software and the switch or to send encrypted data from the switch to an SSH2 client on a remote system. Configuration and policy files may also be transferred to the switch using the Secure Copy Protocol 2 (SCP2) or the Secure File Transfer Protocol (SFTP). Beginning with ExtremeWare XOS 11.2, you can also use SSH2 to connect to other devices from the switch. The ExtremeWare XOS CLI provides a command that enables the switch to function as an SSH2 client, sending commands to a remote system via an SSH2 session. The ExtremeWare XOS SSH2 switch application also works with SSH2 client (version 2.x or later) from SSH Communication Security, and with (version 2.5 or later) from OpenSSH. The SFTP file transfer protocol is required for file transfer using SCP2. The section describes the following topics:

Enabling SSH2 for Inbound Switch Access on page 335 Using ACLs to Control SSH2 Access on page 337 Using SCP2 from an External SSH2 Client on page 338 SSH2 Client Functions on the Switch on page 338

Enabling SSH2 for Inbound Switch Access


SSH2 functionality is not present in the base ExtremeWare XOS software image, but is available as an additional, installable module. Before you can access any SSH2 commands, you must install this additional software module. Without the software module, the commands do not appear on the command line. To install the software module, see the instructions in Appendix A, Software Upgrade and Boot Options. NOTE
Do not terminate the SSH process (exsshd) that was installed since the last reboot unless you have saved your configuration. If you have installed a software module and you terminate the newly installed process without saving your configuration, your module may not be loaded when you attempt to restart the process with the start process command.

ExtremeWare XOS 11.3 Concepts Guide

335

Security Because SSH2 is currently under U.S. export restrictions, you must first obtain and install the ssh.xmod software module from Extreme Networks before you can enable SSH2. You must enable SSH2 on the switch before you can connect to the switch using an external SSH2 client. Enabling SSH2 involves two steps:

Generating or specifying an authentication key for the SSH2 sessions. Enabling SSH2 access by specifying a TCP port to be used for communication and specifying on which virtual router SSH2 is enabled. Once enabled, by default, SSH2 uses TCP port 22 and is available on all virtual routers.

An authentication key must be generated before the switch can accept incoming SSH2 sessions. This can be done automatically by the switch, or you can enter a previously generated key. To have the key generated by the switch, use the following command:
configure ssh2 key

The key generation process can take up to ten minutes. Once the key has been generated, you should save your configuration to preserve the key. To use a key that has been previously created, use the following command:
configure ssh2 key {pregenerated}

You are prompted to enter the pregenerated key.

NOTE
The pregenerated key must be one that was generated by the switch. To get such key, you can use the command show configuration exsshd to display the key on the console. Copy the key to a text editor and remove the carriage return/line feeds from the key. Finally, copy and paste the key into the command line. The key must be entered as one line.

The key generation process generates the SSH2 private host key. The SSH2 public host key is derived from the private host key and is automatically transmitted to the SSH2 client at the beginning of an SSH2 session. To enable SSH2, use the following command:
enable ssh2 {access-profile [<access_profile> | none]} {port <tcp_port_number>} {vr [<vr_name> | all | default]}

You can also specify a TCP port number to be used for SSH2 communication. By default the TCP port number is 22. Beginning with ExtremeWare XOS 11.2, the switch accepts IPv6 connections. Before you initiate a session from an SSH2 client, ensure that the client is configured for any non-default access list or TCP port information that you have configured on the switch. Once these tasks are accomplished, you may establish an SSH2-encrypted session with the switch. Clients must have a valid user name and password on the switch in order to log in to the switch after the SSH2 session has been established. To view the status of SSH2 sessions on the switch, use the show management command. The show management command displays information about the switch including the enable/disable state for SSH2 sessions and whether a valid key is present.

336

ExtremeWare XOS 11.3 Concepts Guide

Secure Shell 2 For additional information on the SSH protocol refer to Federal Information Processing Standards Publication (FIPSPUB) 186, Digital Signature Standard, 18 May 1994. This can be download from: ftp:// ftp.cs.hut.fi/pub/ssh. General technical information is also available from: http://www.ssh.fi

Using ACLs to Control SSH2 Access


You can restrict SSH2 access by creating and implementing an ACL policy. You configure an ACL policy to permit or deny a specific list of IP addresses and subnet masks for the SSH2 port. There are two methods to load ACL policies to the switch:

Use the edit policy command to launch a VI-like editor on the switch. You can create the policy directly on the switch. Use the tftp command to transfer a policy that you created using a text editor on another system to the switch.

For more information about creating and implementing ACLs and policies, see Chapter 12, Policy Manager and Chapter 13, Access Lists (ACLs).

Sample SSH2 Policies


The following are sample policies that you can apply to restrict SSH2 access. In the following example named MyAccessProfile.pol, the switch permits connections from the subnet 10.203.133.0/24 and denies connections from all other addresses:
MyAccessProfile.pol Entry AllowTheseSubnets { if { source-address 10.203.133.0 /24; } then { permit; } }

In the following example named MyAccessProfile_2.pol, the switch does not permit connections from the subnet 10.203.133.0/24 but accepts connections from all other addresses:
MyAccessProfile_2.pol Entry dontAllowTheseSubnets { if { source-address 10.203.133.0 /24; } then { deny; } } Entry AllowTheRest {

ExtremeWare XOS 11.3 Concepts Guide

337

Security
If { ; #none specified } then { permit; } }

Configuring SSH2 to Use ACL Policies


This section assumes that you have already loaded the policy on the switch. For more information about creating and implementing ACLs and policies, see Chapter 12, Policy Manager and Chapter 13, Access Lists (ACLs). To configure SSH2 to use an ACL policy to restrict access, use the following command:
enable ssh2 {access-profile [<access_profile> | none]} {port <tcp_port_number>} {vr [<vr_name> | all | default]}

Use the none option to remove a previously configured ACL.

Using SCP2 from an External SSH2 Client


In ExtremeWare XOS version 11.0 or later, the SCP2 protocol is supported for transferring configuration, and policy files to the switch from the SCP2 client. The user must have administrator-level access to the switch. The switch can be specified by its switch name or IP address. ExtremeWare XOS only allows SCP2 to transfer to the switch files named as follows:

*.cfgExtremeWare XOS configuration files *.polExtremeWare XOS policy files

In the following examples, you are using a Linux system to move files to and from the switch at 192.168.0.120, using the switch administrator account admin.You are logged into your Linux system as user. To transfer the primary configuration file from the switch to your current Linux directory using SCP2, use the following command:
[user@linux-server]# scp2 admin@192.168.0.120:/config/primary.cfg primary.cfg

To copy the policy filename test.pol from your Linux system to the switch, use the following command:
[user@linux-server]# scp2 test.pol admin@192.168.0.120:/config/test.pol

SSH2 Client Functions on the Switch


Beginning with ExtremeWare XOS 11.2, an Extreme Networks switch can function as an SSH2 client. This means you can connect from the switch to a remote device running an SSH2 server and send commands to that device. You can also use SCP2 to transfer files to and from the remote device.

338

ExtremeWare XOS 11.3 Concepts Guide

Secure Socket Layer You do not need to enable SSH2 or generate an authentication key to use the SSH2 and SCP2 commands from the ExtremeWare XOS CLI.

NOTE
The BlackDiamond 8800 family of switches and the Summit X450 switch do not support user-created VRs.

To send commands to a remote system using SSH2, use the following command:
ssh2 {cipher [3des | blowfish]} {port <portnum>} {compression [on | off]} {user <username>} {debug <debug_level>} {<username>@} [<host> | <ipaddress>] {<remote command>} {vr <vr_name>}

The remote commands can be any command acceptable by the remote system. You can specify the login user name as a separate argument or as part of the user@host specification. If the login user name for the remote system is the same as your user name on the switch, you can omit the username parameter entirely. For example, to obtain a directory listing from a remote Linux system with IP address 10.10.0.2 using SSH2, enter the following command:
ssh2 admin@10.10.0.2 ls

To initiate a file copy from a remote system to the switch using SCP2, use the following command:
scp2 {cipher [3des | blowfish]} {port <portnum>} {debug <debug_level>} <user>@ [<hostname> | <ipaddress>]:<remote_file> <local_file> {vr <vr_name>}

For example, to copy the configuration file test.cfg on host system1 to the switch, enter the following command:
scp2 admin@system1:/config/test.cfg localtest.cfg

To initiate a file copy to a remote system from the switch using SCP2, use the following command:
scp2 {cipher [3des | blowfish]} {port <portnum>} {debug <debug_level>} <local_file> <user>@ [<hostname> | <ipaddress>]:<remote_file> {vr <vr_name>}

For example, to copy the configuration file engineering.cfg from the switch to host system1, enter the following command:
scp2 engineering.cfg admin@system1:/config/engineering.cfg

Secure Socket Layer


Secure Socket Layer (SSLv3) is a feature of ExtremeWare XOS that allows you to authenticate and encrypt data over an SSL connection to provide secure communication. The existing web server in ExtremeWare XOS allows HTTP clients to access the network login page. By using HTTPS on the web server, clients securely access the network login page using an HTTPS enabled web browser. Since SSL encrypts the data exchanged between the server and the client, you protect your data, including network login credentials, from unwanted exposure.

ExtremeWare XOS 11.3 Concepts Guide

339

Security HTTPS access is provided through SSL and the Transport Layer Security (TLS1.0). These protocols enable clients to verify the authenticity of the server to which they are connecting, thereby ensuring that users are not compromised by intruders. Similar to SSH2, before you can use any SSL commands, you must first download and install the separate Extreme Networks SSH software module (ssh.xmod). This additional module allows you to configure both SSH2 and SSL on the switch. SSL is packaged with the SSH module; therefore, if you do not install the module, you are unable to configure SSL. If you try to execute SSL commands without installing the module first, the switch notifies you to download and install the module. To install the module, see the instructions in Appendix A, Software Upgrade and Boot Options. You must upload or generate a certificate for SSL server use. Before you can upload a certificate, you must purchase and obtain an SSL certificate from an Internet security vendor. The following security algorithms are supported:

RSA for public key cryptography (generation of certificate and public-private key pair, certificate signing). RSA key size between 1024 and 4096 bits. Symmetric ciphers (for data encryption): RC4, DES, and 3DES. Message Authentication Code (MAC) algorithms: MD5 and SHA.

The Converged Network Analyzer (CNA) Agent requires SSL to encrypt communication between the CNA Agent and the CNA Server. For more information about the CNA Agent, see Appendix C, CNA Agent. This section describes the following topics:

Enabling and Disabling SSL on page 340 Creating Certificates and Private Keys on page 341 Displaying SSL Information on page 343

Enabling and Disabling SSL


This section describes how to enable and disable SSL on your switch. NOTE
Prior to ExtremeWare XOS 11.2, the Extreme Networks SSH module did not include SSL. To use SSL for secure HTTPS web-based login, you must upgrade your core software image to ExtremeWare XOS 11.2 or later, install the SSH module that works in concert with that core software image, and reboot the switch.

Please keep in mind the following guidelines when using SSL:

To use SSL with web-based login (secure HTTP access, HTTPS) you must specify the HTTPS protocol when configuring the redirect URL. If you are downloading the SSH module for the first time and want to immediately use SSL for secure HTTPS web-based login, restart the thttpd process after installing the SSH module. For more detailed information about activating the SSH module, see Guidelines for Activating SSL in Appendix A.

To enable SSL and allow secure HTTP (HTTPS) access on the default port (443), use the following command:
enable web https

340

ExtremeWare XOS 11.3 Concepts Guide

Secure Socket Layer To disable SSL and HTTPS, enter the following command:
disable web https

Creating Certificates and Private Keys


When you generate a certificate, the certificate is stored in the configuration file, and the private key is stored in the EEPROM. The certificate generated is in PEM format. To create a self-signed certificate and private key that can be saved in the EEPROM, use the following command:
configure ssl certificate privkeylen <length> country <code> organization <org_name> common-name <name>

Make sure to specify the following:


Country code (maximum size of 2 characters) Organization name (maximum size of 64 characters) Common name (maximum size of 64)

Any existing certificate and private key is overwritten. The size of the certificate depends on the RSA key length (privkeylen) and the length of the other parameters (country, organization name, and so forth) supplied by the user. If the RSA key length is 1024, then the certificate is approximately 1 kb. For an RSA key length of 4096, the certificate length is approximately 2 kb, and the private key length is approximately 3 kb.

Downloading a Certificate Key from a TFTP Server


You can download a certificate key from files stored in a TFTP server. If the operation is successful, any existing certificate is overwritten. After a successful download, the software attempts to match the public key in the certificate against the private key stored. If the private and public keys do not match, the switch displays a warning message similar to the following: Warning: The Private Key does not match with the Public Key in the certificate. This warning acts as a reminder to also download the private key. Downloaded certificates and keys are not saved across switch reboots unless you save your current switch configuration. Once you issue the save command, the downloaded certificate is stored in the configuration file and the private key is stored in the EEPROM. To download a certificate key from files stored in a TFTP server, use the following command:
download ssl <ip_address> certificate <cert file>

NOTE
For security measures, you can only download a certificate key in the VR-Mgmt virtual router.

To see whether the private key matches with the public key stored in the certificate, use the following command:
show ssl

ExtremeWare XOS 11.3 Concepts Guide

341

Security This command also displays:


HTTPS port configured. This is the port on which the clients will connect. Length of the RSA key (the number of bits used to generate the private key). Basic information about the stored certificate.

Downloading a Private Key from a TFTP Server


To download a private key from files stored in a TFTP server, use the following command:
download ssl <ip_address> privkey <key file>

If the operation is successful, the existing private key is overwritten. After the download is successful, a check is performed to find out whether the private key downloaded matches the public key stored in the certificate. If the private and public keys do not match, the switch displays a warning message similar to the following: Warning: The Private Key does not match with the Public Key in the certificate. This warning acts as a reminder to also download the corresponding certificate. For security reasons, when downloading private keys, Extreme Networks recommends obtaining a pregenerated key rather than downloading a private key from a TFTP server. See Configuring Pregenerated Certificates and Keys on page 342 for more information. Downloaded certificates and keys are not saved across switch reboots unless you save your current switch configuration. Once you issue the save command, the downloaded certificate is stored in the configuration file and the private key is stored in the EEPROM.

Configuring Pre-generated Certificates and Keys


To get the pre-generated certificate from the user, use the following command:
configure ssl certificate pregenerated

You can copy and paste the certificate into the command line followed by a blank line to end the command. This command is also used when downloading or uploading the configuration. Do not modify the certificate stored in the uploaded configuration file because the certificate is signed using the issuers private key. The certificate and private key file should be in PEM format and generated using RSA as the cryptography algorithm. To get the pre-generated private key from the user, use the following command:
configure ssl privkey pregenerated

You can copy and paste the key into the command line followed by a blank line to end the command. This command is also used when downloading or uploading the configuration. The private key is stored in the EEPROM. The certificate and private key file should be in PEM format and generated using RSA as the cryptography algorithm.

342

ExtremeWare XOS 11.3 Concepts Guide

Secure Socket Layer

Displaying SSL Information


Use the following command to display whether the switch has a valid private and public key pair and the state of HTTPS access:
show ssl

ExtremeWare XOS 11.3 Concepts Guide

343

Security

344

ExtremeWare XOS 11.3 Concepts Guide

17 Network Login
This chapter describes the following topics:

Network Login Overview on page 345 Configuring Network Login on page 349 Authenticating Users on page 351 802.1x Authentication on page 359 Web-Based Authentication on page 363 MAC-Based Authentication on page 368 Additional Network Login Configuration Details on page 371

Network Login Overview


Network login controls the admission of user packets into a network by allowing MAC addresses from users that are properly authenticated. Network login is controlled on a per port basis. When network login is enabled on a port, that port does not forward any packets until authentication takes place. Network login is capable of three types of authentication: web-based, MAC-based, and 802.1x. In addition, network login has two different modes of operation: Campus mode and ISP mode. The authentication types and modes of operation can be used in any combination. When web-based network login is enabled on a switch port, that port is placed into a non-forwarding state until authentication takes place. To authenticate, a user must open a web browser and provide the appropriate credentials. These credentials are either approved, in which case the port is placed in forwarding mode, or not approved, in which case the port remains blocked. You can initiate user logout by submitting a logout request or closing the logout window. The following capabilities are included with network login:

Web-based login using HTTP available on each port Web-based login using HTTPSif you install the SSH software module that includes SSLavailable on each port Multiple supplicants for web-based, MAC-based, and 802.1x authentication on each port

The remainder of this section describes the following topics:


Web-Based, MAC-Based, and 802.1x Authentication on page 346 Multiple Supplicant Support on page 347 Campus and ISP Modes on page 348 Network Login and Hitless FailoverModular Switches Only on page 348

ExtremeWare XOS 11.3 Concepts Guide

345

Network Login

Web-Based, MAC-Based, and 802.1x Authentication


Authentication is handled as a web-based process, MAC-based process, or as described in the IEEE 802.1x specification. Web-based network login does not require any specific client software and can work with any HTTP-compliant web browser. By contrast, 802.1x authentication may require additional software installed on the client workstation, making it less suitable for a user walk-up situation, such as a cyber-caf or coffee shop.1 Extreme Networks supports a smooth transition from web-based to 802.1x authentication. MAC-based authentication is used for supplicants that do not support a network login mode, or supplicants that are not aware of the existence of such security measures, for example an IP phone. If a MAC address is detected on a MAC-based enabled network login port, an authentication request is sent once to the AAA application. AAA tries to authenticate the MAC address against the configured Remote Authentication Dial In User Server (RADIUS) server and its configured parameters (timeout, retries, and so on) or the configured local database. The credentials used for this are the supplicants MAC address in ASCII representation and a locally configured password on the switch. If no password is configured the MAC address is also used as the password. You can also group MAC addresses together using a mask. Dynamic Host Control Protocol (DHCP) is required for web-based network login because the underlying protocol used to carry authentication request-response is HTTP. The client requires an IP address to send and receive HTTP packets. Before the client is authenticated, however, the only connection that exists is to the authenticator. As a result, the authenticator must be furnished with a temporary DHCP server to distribute the IP address. The switch responds to DHCP requests for unauthenticated clients when DHCP parameters such as
dhcp-address-range and dhcp-options are configured on the netlogin VLAN. The switch can also

answer DHCP requests following authentication if DHCP is enabled on the specified VLAN. If netlogin clients are required to obtain DHCP leases from an external DHCP server elsewhere on the network, DHCP should not be enabled on the VLAN. The DHCP allocation for network login has a short time duration of 10 seconds and is intended to perform web-based network login only. As soon as the client is authenticated, it is deprived of this address. The client must obtain an operational address from another DHCP server in the network. DHCP is not required for 802.1x, because 802.1x uses only Layer 2 frames (EAPOL) or MAC-based network login. URL redirection (applicable to web-based mode only) is a mechanism to redirect any HTTP request to the base URL of the authenticator when the port is in unauthenticated mode. In other words, when the user tries to log in to the network using the browser, the user is first redirected to the network login page. Only after a successful login is the user connected to the network. URL redirection requires that the switch is configured with a DNS client. Web-based, MAC-based, and 802.1x authentication each have advantages and disadvantages, as summarized next. Advantages of Web-Based Authentication:

Works with any operating system that is capable of obtaining an IP address using DHCP. There is no need for special client side software; only a web browser is needed.

1.

A workstation running Windows 2000 Service Pack 4 or Windows XP supports 802.1x natively and does not require additional authentication software.

346

ExtremeWare XOS 11.3 Concepts Guide

Network Login Overview Disadvantages of Web-Based Authentication:

The login process involves manipulation of IP addresses and must be done outside the scope of a normal computer login process. It is not tied to a Windows login. The client must bring up a login page and initiate a login. Supplicants cannot be re-authenticated transparently. They cannot be re-authenticated from the authenticator side. This method is not as effective in maintaining privacy protection.

Advantages of MAC-Based Authentication:


Works with any operating system or network enabled device. Works silently. The user, client, or device does not know that it gets authenticated. Ease of management. A set of devices can easily be grouped by the vendor part of the MAC address.

Disadvantages of MAC-Based Authentication:


There is no re-authentication mechanism. The FDB aging timer determines the logout. Security is based on the MAC address of the client, so the network is more vulnerable to spoofing attacks.

Advantages of 802.1x Authentication:


In cases where the 802.1x is natively supported, login and authentication happens transparently. Authentication happens at Layer 2. It does not involve getting a temporary IP address and subsequent release of the address to obtain a permanent IP address. Allows for periodic, transparent re-authentication of supplicants.

Disadvantages of 802.1x Authentication:


802.1x native support is available only on newer operating systems, such as Windows XP. 802.1x requires an EAP-capable RADIUS Server. Most current RADIUS servers support EAP, so this is not a major disadvantage. Transport Layer Security (TLS) and Tunneled TLS (TTLS) authentication methods involve Public Key Infrastructure (PKI), which adds to the administrative requirements.

Multiple Supplicant Support


An important enhancement over the IEEE 802.1x standard is that ExtremeWare XOS supports multiple clients (supplicants) to be individually authenticated on the same port. This feature makes it possible for two or more client stations to be connected to the same port, with some being authenticated while others are not. A port's authentication state is the logical OR of the individual MAC's authentication states. In other words, a port is authenticated if any of its connected clients is authenticated. Multiple clients can be connected to a single port of authentication server through a hub or layer-2 switch. Multiple supplicants are supported in ISP mode for both web-based and 802.1x authentication. On the BlackDiamond 10K switch, multiple supplicants are supported in Campus mode only if all supplicants move to the same VLAN. On the BlackDiamond 8800 family of switches and the Summit X450 switch, multiple supplicants are supported in Campus mode if you configure and enable netlogin MAC-based VLANs. Netlogin MAC-based VLANs are not supported on the BlackDiamond 10K switch or 10 Gigabit Ethernet ports. For more information, see Configuring Netlogin MAC-Based VLANsBlackDiamond 8800 Family of Switches and the Summit X450 Switch Only on page 372.

ExtremeWare XOS 11.3 Concepts Guide

347

Network Login The choice of web-based versus 802.1x authentication is again on a per-MAC basis. Among multiple clients on the same port, it is possible that some clients use web-based mode to authenticate, and some others use 802.1x. This is not true if you configure netlogin MAC-based VLANs on the BlackDiamond 8800 family of switches of the Summit X450 switch. For more information, see Configuring Netlogin MAC-Based VLANsBlackDiamond 8800 Family of Switches and the Summit X450 Switch Only on page 372.

NOTE
With multiple supplicant support, after the first MAC is authenticated, the port is transitioned to the authenticated state and other unauthenticated MACs can listen to all data destined for the first MAC. Please be aware of this as unauthenticated MACs can listen to all broadcast and multicast traffic directed to a network login-authenticated port.

Campus and ISP Modes


Network login supports two modes of operation, Campus and ISP. Campus mode is intended for mobile users who tend to move from one port to another and connect at various locations in the network. ISP mode is meant for users who connect through the same port and VLAN each time (the switch functions as an ISP). In Campus mode, the clients are placed into a permanent VLAN following authentication with access to network resources. For wired ports, the port is moved from the temporary to the permanent VLAN. In ISP mode, the port and VLAN remain constant. Before the supplicant is authenticated, the port is in an unauthenticated state. After authentication, the port forwards packets. You do not explicitly configure the mode of operation; rather, the presence of any Extreme Networks Vendor Specific Attribute (VSA) that has a VLAN name or VLAN ID (any VLAN attribute) in the RADIUS server determines the mode of operation. If a VLAN attribute is present, it is assumed to be Campus mode. If a VLAN attribute is not present, it is assumed to be ISP mode.

Network Login and Hitless FailoverModular Switches Only


When you install two Management Switch Fabric Module (MSM) modules in a BlackDiamond chassis, one MSM assumes the role of primary and the other assumes the role of backup MSM. The primary MSM executes the switchs management functions, and the backup MSM acts in a standby role. Hitless failover transfers switch management control from the primary MSM to the backup MSM. NOTE
Beginning with ExtremeWare XOS 11.3, both the BlackDiamond 10K switch and the BlackDiamond 8800 family of switches (formerly known as Aspen) support hitless failover for network login. If you are running an earlier version of ExtremeWare, the modular switches do not support network login hitless failover.

Network login supports hitless failover by relaying current client authentication information from the master MSM to the backup MSM. For example, if a client moves to the authenticated state, or moves from an authenticated state to an unauthenticated state, the primary MSM conveys this information to the backup MSM. If failover occurs, your authenticated client continues to operate as before the failover.

348

ExtremeWare XOS 11.3 Concepts Guide

Configuring Network Login

NOTE
If you use 802.1x network login, authenticated clients remain authenticated during failover; however, shortly after failover, all authenticated clients automatically re-authenticate themselves. Re-authentication occurs without user intervention.

If failover occurs during the authentication or re-authentication of a client, the client must repeat the authentication process. To initiate hitless MSM failover on a network that uses network login: 1 Confirm that the MSMs are synchronized and have identical software and switch configurations using the show switch {detail} command. The output displays the status of the MSMs, with the primary MSM showing MASTER and the backup MSM showing BACKUP (InSync). If the MSMs are not synchronized, proceed to step 2. If the MSMs are synchronized, proceed to step 3. 2 If the MSMs are not in sync, replicate all saved images and configurations from the primary to the backup using the synchronize command. 3 Initiate failover using the run msm-failover command. For more detailed information about verifying the status of the MSMs and system redundancy, see Understanding System Redundancy with Dual MSMs InstalledModular Switches Only on page 70. For more information about hitless failover, see Understanding Hitless Failover SupportModular Switches Only on page 74.

Configuring Network Login


This section provides a general overview of the commands used for:

Enabling or Disabling Network Login on the Switch on page 350 Enabling or Disabling Network Login on a Specific Port on page 350 Configuring the Move Fail Action on page 350 Displaying Network Login Settings on page 350

This section also contains information about the Exclusions and Limitations of network login. For more detailed information about a specific mode of network login, including configuration examples, please refer to the following sections:

802.1x Authentication on page 359 Web-Based Authentication on page 363 MAC-Based Authentication on page 368

ExtremeWare XOS 11.3 Concepts Guide

349

Network Login

Enabling or Disabling Network Login on the Switch


To enable or disable network login, use one of the following commands and specify the authentication method:
enable netlogin [{dot1x} {mac} {web-based}] disable netlogin [{dot1x} {mac} {web-based}]

By default netlogin is disabled.

Enabling or Disabling Network Login on a Specific Port


To enable network login on a port, use the following command to specify the ports and the authentication method:
enable netlogin ports <portlist> [{dot1x} {mac} {web-based}]

By default, all methods of network login are disabled on all ports. Network login must be disabled on a port before you can delete a VLAN that contains that port. To disable network login, use the following command:
disable netlogin ports <portlist> [{dot1x} {mac} {web-based}]

Configuring the Move Fail Action


If network login fails to perform Campus mode login, you can configure the switch to authenticate the client in the original VLAN or deny authentication even if the user name and password are correct. For example, this may occur if a destination VLAN does not exist. To configure the behavior of network login if a VLAN move fails, use the following command:
configure netlogin move-fail-action [authenticate | deny]

By default, the setting is deny. The following describes the parameters of this command if two clients want to move to a different untagged VLAN on the same port:

authenticateNetwork login authenticates the first client that requests a move and moves that client to the requested VLAN. Network login authenticates the second client but does not move that client to the requested VLAN. The second client moves to the first clients authenticated VLAN. denyNetwork login authenticates the first client that requests a move and moves that client.

Network login does not authenticate the second client.

Displaying Network Login Settings


To display the network login settings and parameters, use the following command:
show netlogin {port <portlist> vlan <vlan_name>} {dot1x {detail}} {mac} {web-based}

350

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users

Exclusions and Limitations


The following are limitations and exclusions for network login:

All unauthenticated MACs will be seeing broadcasts and multicasts sent to the port if even a single MAC is authenticated on that port. Network login must be disabled on a port before that port can be deleted from a VLAN. In Campus mode on the BlackDiamond 8800 family of switches and the Summit X450 switch, with untagged VLANs and the netlogin ports mode configured as port-mode, after the port moves to the destination VLAN, the original VLAN for that port is not displayed. A network login VLAN port should not be a part of following protocols:

Ethernet Automatic Protection Switching (EAPS) Extreme Standby Router Protocol (ESRP) Spanning Tree Protocol (STP) Link Aggregation

Authenticating Users
Network login uses two methods to authenticate users trying to access the network:

RADIUS servers Local database

All three network login protocols, web-based, MAC-based, and 802.1x netlogin, support RADIUS authentication. Only web-based and MAC-based netlogin support local database authentication. This section describes the following topics in greater detail:

Creating User Accounts on the RADIUS Server on page 351 Configuring Local Database Authentication on page 355

Creating User Accounts on the RADIUS Server


You can create two types of user accounts on your RADIUS server for authenticating network login users: netlogin-only enabled and netlogin-only disabled. A netlogin-only disabled user can log in using network login and can also access the switch using Telnet or SSH. A netlogin-only enabled user can only log in using network login and cannot access the switch using the same login. NOTE
For information on how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

In the following example using FreeRADIUS, you add the configuration to the RADIUS server users file. The users file determines which attributes are sent back by the RADIUS server to the RADIUS client (an Extreme Networks switch). Depending on your RADIUS server, where and how you add the configuration might be different.

ExtremeWare XOS 11.3 Concepts Guide

351

Network Login Add the following line to the RADIUS server users file for netlogin-only disabled users:
Extreme:Extreme-Netlogin-Only = Disabled

Add the following line to the RADIUS server users file for netlogin-only enabled users:
Extreme:Extreme-Netlogin-Only = Enabled

Table 49 contains the Vendor Specific Attribute (VSA) definitions for web-based, MAC-based, and 802.1x network login. The Extreme Network Vendor ID is 1916.

Table 49: VSA Definitions for Web-based, MAC-based, and 802.1x network login
VSA Extreme: NetloginExtended-VLAN Vendor Type 211 Type String Sent-in Access-Accept Description Name or ID of the destination VLAN after successful authentication (must already exist on switch). NOTE: When using this attribute, specify whether the port should be moved tagged or untagged to the VLAN. Please see the guidelines listed on page 353 for more information. Extreme: NetloginVLAN-Name Extreme: NetloginVLAN-ID Extreme: Netlogin-URL Extreme: NetloginURL-Desc Extreme: Netlogin-Only 203 209 204 205 206 String Integer String String Integer Access-Accept Access-Accept Access-Accept Access-Accept Access-Accept Name of destination VLAN after successful authentication (must already exist on switch). ID of destination VLAN after successful authentication (must already exist on switch). Destination web page after successful authentication. Text description of network login URL attribute. Indication of whether the user can authenticate using other means, such as telnet, console, SSH, or Vista. A value of 1 (enabled) indicates that the user can only authenticate via network login. A value of zero (disabled) indicates that the user can also authenticate via other methods.

Table 50 contains the standard RADIUS attributes used by network login.

Table 50: Standard RADIUS attributes used by network login


Attribute IETF: Tunnel-Type IETF: Tunnel-Medium-Type Attribute Value 64 65 Type Integer Integer Sent-in Access-Accept Access-Accept Description Specifies the tunneling protocol that is used. Specifies the transport medium used when creating a tunnel for protocols (for example, VLANs) that can operate over multiple transports. Specifies the VLAN ID of the destination VLAN after successful authentication; used to derive the VLAN name.

IETF: Tunnel-Private-Group-ID

81

String

Access-Accept

352

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users The NetLogin-Url and NetLogin-Url-Desc attributes are used in case of Web-based login as the page to use for redirection after a successful login. Other authentication methods will ignore these attributes. The other attributes are used in the following order to determine the destination VLAN to use:

Extreme: Netlogin-Extended-VLAN (VSA 211) Extreme: Netlogin-VLAN-Name (VSA 203) Extreme: Netlogin-VLAN-ID (VSA 209) IETF: Tunnel-Private-Group-ID representing the VLAN TAG as a string, but only if IETF: TunnelType == VLAN(13) and IETF: Tunnel-Medium-Type == 802 (6).

If none of the previously described attributes are present ISP mode is assumed, and the client remains in the configured VLAN.

Guidelines and Examples for Using VSAs


This section contains guidelines and examples for using the Extreme Networks VSAs listed in Table 49. The examples in this section use FreeRADIUS to modify the VSA. Depending on your RADIUS server, configuration might be different. NOTE
For information on how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

VSA 211Extreme: Netlogin-Extended-VLAN. The following describes the guidelines for VSA 211:

For tagged VLAN movement with 802.1x netlogin, you must use VSA 211. For untagged VLAN movement with 802.1x netlogin, you can use all current Extreme Networks VLAN VSAs: VSA 203, VSA 209, and VSA 211. To specify the VLAN name or the VLAN ID, use an ASCII string; however, you cannot specify both the VLAN name and the VLAN ID at the same time. If the string only contains numbers, it is interpreted as the VLAN ID. For tagged VLANs, specify T for tagged before the VLAN name or VLAN ID. For untagged VLANs, specify U for untagged before the VLAN name or VLAN ID. For movement based on the incoming ports traffic, specify * before the VLAN name or VLAN ID. The behavior can be either tagged or untagged, based on the incoming ports traffic, and mimics the behavior of VSA 203 and VSA 209, respectively.

VSA 211 Examples. The following examples use FreeRADIUS to modify the VSA to support tagged or untagged VLANs using either the VLAN name or the VLAN ID.

Configuring VLAN names The three options to use when configuring VLAN names are:

TInclude before the VLAN name for a tagged VLAN UInclude before the VLAN name for an untagged VLAN *Include before the VLAN name for movement based on the incoming ports traffic (mimics the behavior of VSA 203)

To configure the tagged VLAN voice, do the following:


Extreme-Netlogin-Extended-VLAN = Tvoice

ExtremeWare XOS 11.3 Concepts Guide

353

Network Login To configure the untagged VLAN data, do the following:


Extreme-Netlogin-Extended-VLAN = Udata

To configure the VLAN orange to be tagged or untagged based on the incoming ports traffic, do the following:
Extreme-Netlogin-Extended-VLAN = *orange

Configuring VLAN IDs The same is true of configuring the VLAN ID. The three options to use when configuring VLAN IDs are:

TInclude before the VLAN ID for a tagged VLAN UInclude before the VLAN ID for an untagged VLAN *Include before the VLAN name for movement based on the incoming ports traffic (mimics the behavior of VSA 209)

To configure a tagged VLAN with a VLAN ID of 229, do the following:


Extreme-Netlogin-Extended-VLAN = T229

To configure an untagged VLAN with a VLAN ID of 4091, do the following:


Extreme-Netlogin-Extended-VLAN = U4091

To configure a VLAN with a VLAN ID of 145 to be tagged or untagged based on the incoming ports traffic, do the following:
Extreme-Netlogin-Extended-VLAN = *145

VSA 203Extreme: Netlogin-VLAN-Name. The following describes the guidelines for VSA 203:

For untagged VLAN movement with 802.1x netlogin, you can use all current Extreme Networks VLAN VSAs: VSA 203, VSA 209, and VSA 211. To specify the VLAN name, use an ASCII string.

When using this VSA, you do not specify a tagged or untagged VLAN. VSA 203 Example. The following example modifies the VSA to specify the name of the destination VLAN. To configure VLAN purple as the destination VLAN, do the following:
Extreme: Netlogin-VLAN-Name = purple

VSA 209Extreme: Netlogin-VLAN-ID. The following describes the guidelines for VSA 209:

For untagged VLAN movement with 802.1x netlogin, you can use all current Extreme Networks VLAN VSAs: VSA 203, VSA 209, and VSA 211. To specify the VLAN ID, use an ASCII string.

When using this VSA, you do not specify a tagged or untagged VLAN. VSA 209 Example. The following example modifies the VSA to specify the VLAN ID (tag) of the destination VLAN. To configure the VLAN with VLAN ID 234 as the destination VLAN, do the following:
Extreme: Netlogin-VLAN-ID = 234

VSA 204Extreme: Netlogin-URL. The following describes the guidelines for VSA 204:

To specify the URL to display after authentication, use an ASCII string.

354

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users

If you do not specify a URL, the network login infrastructure uses the default redirect page URL, http://www.extremenetworks.com, or the URL that you configured using the configure netlogin redirect-page command.

VSA 204 applies only to the web-based authentication mode of Network Login. VSA 204 Example. The following example modifies the VSA to specify the destination URL after successful authentication. To configure the redirect URL as http://www.myhomepage.com, do the following:
Extreme: Netlogin-URL = http://www.myhomepage.com

VSA 205Extreme: Netlogin-URL-Desc. The following describes the guidelines for VSA 205:

To include a description of the redirect page URL (as specified by VSA 204), use an ASCII string. To let the user know where they will be redirected to after authentication, use an ASCII string to provide a brief description of the URL.

VSA 205 applies only to the web-based authentication mode of Network Login. VSA 205 Example. The following example modifies the VSA to describe the network login URL. To describe the network login URL as my home page, do the following:
Extreme: Netlogin-URL-Desc = homepage

VSA 206Extreme: Netlogin-Only. The following describes the guidelines for VSA 206:

To specify that a user can authenticate only via network login, use a value of 1 (enabled). To specify that a user can authenticate via other methods, use a value of 0 (disabled).

VSA 206 Example. See the examples described in the section Creating User Accounts on the RADIUS Server on page 351.

Configuring Local Database Authentication


You can configure the switch to use its local database for web-based and MAC-based network login authentication. 802.1x network login does not support local database authentication. Local authentication essentially mimics the functionality of the remote RADIUS server locally. This method of authentication is useful in the following situations:

If both the primary and secondary (if configured) RADIUS servers timeout or are unable to respond to authentication requests. If no RADIUS servers are configured. If the RADIUS server used for network login authentication is disabled.

If any of the above conditions are met, the switch checks for a local user account and attempts to authenticate against that local account. For local authentication to occur, you must configure the switchs local database with a user name and password for network login. Beginning with ExtremeWare XOS 11.3 you can also specify the destination VLAN to enter upon a successful authentication. The following sections describe the commands used to configure your switch for local database authentication. If you have a BlackDiamond 8800 family switch or a Summit X450 switch, you can also use local database authentication in conjunction with netlogin MAC-based VLANs. For more detailed

ExtremeWare XOS 11.3 Concepts Guide

355

Network Login information about netlogin MAC-based VLANs, see Configuring Netlogin MAC-Based VLANs BlackDiamond 8800 Family of Switches and the Summit X450 Switch Only on page 372. This section describes the following topics:

Creating a Local Netlogin AccountUser Name and Password Only on page 356 Specifying a Destination VLAN on page 357 Modifying an Existing Local Netlogin Account on page 358 Displaying Local Netlogin Accounts on page 359 Deleting a Local Netlogin Account on page 359

Creating a Local Netlogin AccountUser Name and Password Only


To create a local netlogin user name and password, use the following command and specify the <username> parameter: create netlogin local-user <user-name> {encrypted <password>} {vlan-vsa [[{tagged | untagged} [<vlan_name>] | <vlan_tag>]]}

User names are not case-sensitive; passwords are case-sensitive. User names must have a minimum of 1 character and a maximum of 32 characters. Passwords must have a minimum of 0 characters and a maximum of 32 characters. If you use RADIUS for authentication, Extreme Networks recommends that you use the same user name and password for both local authentication and RADIUS authentication. If you attempt to create a user name with more than 32 characters, the switch displays the following messages:
%% Invalid name detected at '^' marker. %% Name cannot exceed 32 characters.

If you attempt to create a password with more than 32 characters, the switch displays the following message after you re-enter the password:
Password cannot exceed 32 characters

The encrypted option is used by the switch to encrypt the password. Do not use this option through the command line interface (CLI). After you enter a local netlogin user name, press [Enter]. The switch prompts you twice to enter the password. The following example:

Creates a new local netlogin user name Creates a password associated with the local netlogin user name.

The following is a sample display from this command:


create netlogin local-user megtest password: <Enter the password. The switch does not display the password.> Reenter password: <Re-enter the password. The switch does not display the password.>

For information about specifying the destination VLAN, see the next section Specifying a Destination VLAN.

356

ExtremeWare XOS 11.3 Concepts Guide

Authenticating Users

Specifying a Destination VLAN


If you configure a local netlogin account with a destination VLAN, upon successful authentication, the client transitions to the permanent, destination VLAN. You can specify the destination VLAN when you initially create the local netlogin account or at a later time. Adding VLANs when Creating a Local Netlogin Account. To specify the destination VLAN when creating the local netlogin account, use the following command and specify the vlan-vsa option with the associated parameters:
create netlogin local-user <user-name> {encrypted <password>} {vlan-vsa [[{tagged | untagged} [<vlan_name>] | <vlan_tag>]]}

Where the following is true:


taggedSpecifies that the client be added as tagged untaggedSpecifies that the client be added as untagged vlan_nameSpecifies the name of the destination VLAN vlan_tagSpecifies the VLAN ID, tag, of the destination VLAN

The following example:


Creates a new local netlogin user name Creates a password associated with the local netlogin user name Adds the VLAN test1 as the destination VLAN

The following is a sample display from this command:


create netlogin local-user megtest vlan-vsa "test1" password: <Enter the password. The switch does not display the password.> Reenter password: <Re-enter the password. The switch does not display the password.>

Adding VLANs at a Later Time. To specify the destination VLAN after you created the local netlogin account, use the following command:
configure netlogin local-user <user-name> {vlan-vsa [[{tagged | untagged} [<vlan_name>] | <vlan_tag>]] | none]}

Where the following is true:


taggedSpecifies that the client be added as tagged untaggedSpecifies that the client be added as untagged vlan_nameSpecifies the name of the destination VLAN vlan_tagSpecifies the VLAN ID, tag, of the destination VLAN noneSpecifies that the VSA 211 wildcard (*) is applied, only if you do not specify tagged or untagged

The following example:


Modifies a previously created local netlogin account Specifies that clients are added as tagged to the VLAN Adds the VLAN blue as the destination VLAN

configure netlogin local-user megtest vlan-vsa tagged "blue"

ExtremeWare XOS 11.3 Concepts Guide

357

Network Login

Modifying an Existing Local Netlogin Account


After you create a local netlogin user name and password, you can update the following attributes of that account:

Password of the local netlogin account Destination VLAN attributes including: adding clients tagged or untagged, the name of the VLAN, and the VLAN ID

If you try modifying a local netlogin account that is not present on the switch, or you incorrectly enter the name of the account, output similar to the following appears:
* SummitX450.14 # configure netlogin local-user purplenet ^ %% Invalid input detected at '^' marker.

To confirm the names of the local netlogin accounts on your switch, use the following command:
show netlogin local-users

Updating the Local Netlogin Password. To update the password of an existing local netlogin account, use the following command:
configure netlogin local-user <user_name>

Where user_name specifies the name of the existing local netlogin account. After you enter the local netlogin user name, press [Enter]. The switch prompts you to enter a password. At the prompt enter the new password and press [Enter]. The switch then prompts you to reenter the password. Passwords are case-sensitive. Passwords must have a minimum of 0 characters and a maximum of 32 characters. If you attempt to create a password with more than 32 characters, the switch displays the following message after you re-enter the password:
Password cannot exceed 32 characters

The following example modifies the password for the existing local netlogin account megtest. The following is a sample display from this command:
configure netlogin local-user megtest password: <Enter the new password. The switch does not display the password.> Reenter password: <Re-enter the new password. The switch does not display the password.>

After you complete these steps, the password has been updated. Updating VLAN Attributes. You can add a destination VLAN, change the destination VLAN, or remove the destination VLAN from an existing local netlogin account. To make any of these VLAN updates, use the following command:
configure netlogin local-user <user-name> {vlan-vsa [[{tagged | untagged} [<vlan_name>] | <vlan_tag>]] | none]}

Where the following is true:


user_nameSpecifies the name of the existing local netlogin account taggedSpecifies that the client be added as tagged untaggedSpecifies that the client be added as untagged

358

ExtremeWare XOS 11.3 Concepts Guide

802.1x Authentication

vlan_nameSpecifies the name of the destination VLAN vlan_name_tagSpecifies the VLAN ID, tag, of the destination VLAN noneSpecifies that the VSA 211 wildcard (*) is applied, only if you do not specify tagged or untagged

Displaying Local Netlogin Accounts


To display a list of local netlogin accounts on the switch, including VLAN information, use the following command:
show netlogin local-users

Deleting a Local Netlogin Account


To delete a local netlogin user name and password, use the following command:
delete netlogin local-user <user-name>

802.1x Authentication
802.1x authentication methods govern interactions between the supplicant (client) and the authentication server. The most commonly used methods are Transport Layer Security (TLS); Tunneled TLS (TTLS), which is a Funk/Certicom standards proposal; and PEAP. TLS is the most secure of the currently available protocols, although TTLS is advertised to be as strong as TLS. Both TLS and TTLS are certificate-based and require a Public Key Infrastructure (PKI) that can issue, renew, and revoke certificates. TTLS is easier to deploy, as it requires only server certificates, by contrast with TLS, which requires client and server certificates. With TTLS, the client can use the MD5 mode of user name/password authentication. If you plan to use 802.1x authentication, refer to the documentation for your particular RADIUS server, and 802.1x client on how to set up a PKI configuration. This section describes the following topics:

Interoperability Requirements on page 359 Enabling and Disabling 802.1x Network Login on page 360 802.1x Network Login Configuration Example on page 361 Configuring Guest VLANs on page 361 Post-authentication VLAN Movement on page 363

Interoperability Requirements
For network login to operate, the user (supplicant) software and the authentication server must support common authentication methods. Not all combinations provide the appropriate functionality.

ExtremeWare XOS 11.3 Concepts Guide

359

Network Login

Supplicant Side
The supported 802.1x clients (supplicants) are Windows 2000 SP4 native client, Windows XP native clients, and Meetinghouse AEGIS. A Windows XP 802.1x supplicant can be authenticated as a computer or as a user. Computer authentication requires a certificate installed in the computer certificate store, and user authentication requires a certificate installed in the individual user's certificate store. By default, the Windows XP machine performs computer authentication as soon as the computer is powered on, or at link-up when no user is logged into the machine. User authentication is performed at link-up when the user is logged in. Windows XP also supports guest authentication, but this is disabled by default. Refer to relevant Microsoft documentation for further information. The Windows XP machine can be configured to perform computer authentication at link-up even if user is logged in.

Authentication Server Side


The RADIUS server used for authentication must be EAP-capable. Consider the following when choosing a RADIUS server:

Types of authentication methods supported on RADIUS, as mentioned previously. Need to support VSAs. Parameters such as Extreme-Netlogin-Vlan-Name (destination vlan for port movement after authentication) and Extreme-NetLogin-Only (authorization for network login only) are brought back as VSAs. Need to support both EAP and traditional user name-password authentication. These are used by network login and switch console login respectively. NOTE

For information on how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

Enabling and Disabling 802.1x Network Login


To enable 802.1x network login on the switch, use the following command:
enable netlogin dot1x

Any combination of types of authentication can be enabled on the same switch. At least one of the authentication types must be specified on the CLI. To disable 802.1x network login on the switch, use the following command:
disable netlogin dot1x

To enable 802.1x network login on one or more ports, use the following command:
enable netlogin ports <portlist> dot1x

Network Login must be disabled on a port before you can delete a VLAN that contains that port. To disable 802.1x network login on one or more ports, use the following command:
disable netlogin ports <portlist> dot1x

360

ExtremeWare XOS 11.3 Concepts Guide

802.1x Authentication

802.1x Network Login Configuration Example


The following configuration example shows the Extreme Networks switch configuration needed to support the 802.1x network login example. NOTE
In the following sample configuration, any lines marked (Default) represent default settings and do not need to be explicitly configured. create vlan temp create vlan corp configure vlan default delete ports 4:1-4:4 # Configuration Information for VLAN corp # No VLAN-ID is associated with VLAN corp. configure vlan corp protocol ANY (Default) configure vlan corp ipaddress 10.203.0.224 255.255.255.0 # Configuration Information for VLAN Mgmt configure vlan Mgmt ipaddress 10.10.20.30 255.255.255.0 # Network Login Configuration configure netlogin vlan temp enable netlogin dot1x enable netlogin ports 1:10-1:14, 4:1-4:4 dot1x # RADIUS Configuration configure radius netlogin primary server 10.0.1.2 1812 client-ip 10.10.20.30 vr VRMgmt configure radius netlogin primary shared-secret purple enable radius

The following example is for the FreeRADIUS server; the configuration might be different for your RADIUS server:
#RADIUS Server Setting, in this example the user name is eaptest eaptest Auth-Type := EAP, User-Password == "eaptest" Session-Timeout = 120, Termination-Action =1

NOTE
For information about how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

Configuring Guest VLANs


802.1x authentication supports the concept of guest VLANs. A guest VLAN provides limited or restricted network access if a supplicant does not respond to the 802.1x authentication requests sent by the switch. You configure a guest VLAN only on netlogin ports with 802.1x enabled; movement to a guest VLAN is not supported on netlogin ports with MAC-based or web-based authentication. 802.1x must be the only authentication method enabled on the port for movement to guest VLAN. A port always moves untagged into the guest VLAN.

ExtremeWare XOS 11.3 Concepts Guide

361

Network Login With a guest VLAN configured, if a supplicant does not have 802.1x enabled and does not respond to 802.1x authentication requests sent by the switch, the supplicant moves to a guest VLAN. Upon entering the guest VLAN, the supplicant gains limited network access. You configure the amount of network access granted to clients in the guest VLAN. If a supplicant responds to 802.1x authentication requests, the supplicant gains network accesses based on its credentials.

NOTE
The supplicant does not move to a guest VLAN if it fails authentication after an 802.1x exchange; the supplicant moves to the guest VLAN only if it does not respond to an 802.1x authentication request.

Suppose you have a meeting that includes company employees and visitors from outside the company. In this scenario, your employees have 802.1x enabled supplicants (clients) but your visitors do not. By configuring a guest VLAN, when your employees log into the network, they are granted network access (based on their user credentials and 802.1x enabled clients). However, when the visitors attempt to log into the network, they are granted limited network access because they do not have 802.1x enabled clients. The visitors might be able to reach the Internet, but they are unable to access your network. By default, the switch uses the supplicant response timer and attempts to authenticate the supplicant every 30 seconds for a maximum of three tries. If the supplicant does not respond to the authentication requests, the supplicant moves to the guest VLAN. The number of authentication attempts is not a userconfigured parameter. The port moves out of the guest VLAN if, during subsequent authentications, the port is successfully authenticated and the RADIUS server indicates a different VLAN to move to. This section contains the following topics:

Creating a Guest VLAN on page 362 Enabling a Guest VLAN on page 362 Modifying the Supplicant Response Timer on page 363 Disabling a Guest VLAN on page 363

Creating a Guest VLAN


To create a guest VLAN, use the following command:
configure netlogin dot1x guest-vlan <vlan_name>

NOTE
You configure only one guest VLAN per virtual router (VR).

Enabling a Guest VLAN


To enable the guest VLAN, use the following command:
enable netlogin dot1x guest-vlan ports [all | <ports>]

362

ExtremeWare XOS 11.3 Concepts Guide

Web-Based Authentication

Modifying the Supplicant Response Timer


To modify the supplicant response timer, use the following command and specify the supp-resptimeout parameter:
configure netlogin dot1x timers [{server-timeout <server_timeout>} {quiet-period <quiet_period>} {reauth-period <reauth_period>} {supp-resp-timeout <supp_resp_timeout>}]

The default supplicant response timeout is 30 seconds. The number of authentication attempts is not a user-configured parameter.

Disabling a Guest VLAN


To disable the guest VLAN, use the following command:
disable netlogin dot1x guest-vlan ports [all | <portlist>]

Post-authentication VLAN Movement


Once the client has been successfully authenticated and the port has been moved to a VLAN, the client can move to a VLAN other than the one it was authenticated on. This occurs when the RADIUS server sends a message to the client telling it of the new VLAN during 802.1x re-authentication. The client remains authenticated during this transition. This occurs on both untagged and tagged VLANs. For example, suppose a client submits the required credentials for network access; however, the client is not running the current, approved anti-virus software or the client has not installed the appropriate software updates. If this occurs, the client is authenticated but has limited network access until the problem is resolved. After you update the clients anti-virus software, or install the software updates, the RADIUS server re-authenticates the client by sending ACCESS-ACCEPT messages with the accompanying VLAN attributes, thereby allowing the client to enter its permanent VLAN with full network access. This is normal and expected behavior; no configuration is necessary.

Web-Based Authentication
This section describes web-based network login. For web-based authentication, you need to configure the switch DNS name, default redirect page, session refresh, and logout-privilege. URL redirection requires the switch to be assigned a DNS name. The default name is network-access.net. Any DNS query coming to the switch to resolve switch DNS name in unauthenticated mode is resolved by the DNS server on the switch in terms of the interface (to which the network login port is connected to) IPaddress. This section describes the following topics:

Enabling and Disabling Web-Based Network Login on page 364 Configuring the Base URL on page 364 Configuring the Redirect Page on page 364 Configuring Session Refresh on page 365 Configuring Logout Privilege on page 365

ExtremeWare XOS 11.3 Concepts Guide

363

Network Login

Web-Based Network Login Configuration Example on page 365 Web-Based Authentication User Login on page 367

Enabling and Disabling Web-Based Network Login


To enable web-based network login on the switch, use the following command:
enable netlogin web-based

Any combination of types of authentication can be enabled on the same switch. At least one of the authentication types must be specified on the CLI. To disable web-based network login on the switch, use the following command:
disable netlogin web-based

To enable web-based network login on one or more ports, use the following command:
enable netlogin ports <portlist> web-based

Network Login must be disabled on a port before you can delete a VLAN that contains that port. To disable web-based network login on one or more ports, use the following command:
disable netlogin ports <portlist> dot1x

Configuring the Base URL


To configure the network login base URL, use the following command:
configure netlogin base-url <url>

Where <url> is the DNS name of the switch. For example, configure netlogin base-url networkaccess.net makes the switch send DNS responses back to the netlogin clients when a DNS query is made for network-access.net.

Configuring the Redirect Page


To configure the network login redirect page, use the following command:
configure netlogin redirect-page <url>

Where <url> defines the redirection information for the users once logged in. You must configure a complete URL starting with http:// or https:// By default, the redirect URL value is http://www.extremenetworks.com. This redirection information is used only in case the redirection info is missing from RADIUS server. For example, configure netlogin base-url http://www.extremenetworks.com redirects all users to this URL after they get logged in. To support https, you must first download and install the separate Extreme Networks SSH software module (ssh.xmod). This additional module allows you to configure both SSH2 and SSL on the switch. For more information about SSH2, see Chapter 16, Security. For information about installing the SSH module, see Appendix A, Software Upgrade and Boot Options.

364

ExtremeWare XOS 11.3 Concepts Guide

Web-Based Authentication

Configuring Session Refresh


To enable or disable the network login session refresh, use one of the following commands:
enable netlogin session-refresh {<minutes>} disable netlogin session-refresh

Where <minutes> ranges from 1 - 255. The default setting is 3 minutes. enable netlogin sessionrefresh makes the logout window refresh itself at every configured time interval. Session -refresh is disabled by default. When you configure the network login session refresh for the logout window, ensure that the FDB aging timer is greater than the network login session refresh timer.

Configuring Logout Privilege


To enable or disable network login logout privilege, use one of the following commands:
enable netlogin logout-privilege disable netlogin logout-privilege

These commands turn the privilege for netlogin users to logout by popping up (or not popping up) the logout window. Logout-privilege is enabled by default.

Web-Based Network Login Configuration Example


The following configuration example shows both the Extreme Networks switch configuration and the Radius server entries needed to support the example. VLAN corp is assumed to be a corporate subnet which has connections to DNS, WINS servers, network routers, and so on. VLAN temp is a temporary VLAN and is created to provide connections to unauthenticated network login clients. Unauthenticated ports belong to the VLAN temp. This kind of configuration provides better security as unauthenticated clients do not connect to the corporate subnet and will not be able to send or receive any data. They have to get authenticated in order to have access to the network.

ISP ModeNetwork login clients connected to ports 1:10 - 1:14, VLAN corp, will be logged into the network in ISP mode. This is controlled by the fact that the VLAN in which they reside in unauthenticated mode and the RADIUS server Vendor Specific Attributes (VSA), ExtremeNetlogin-Vlan, are the same, corp. So there will be no port movement. Also if this VSA is missing from RADIUS server, it is assumed to be ISP Mode. Campus ModeOn the other hand, clients connected to ports 4:1 - 4:4, VLAN temp, will be logged into the network in Campus mode since the port will move to the VLAN corp after getting authenticated. A port moves back and forth from one VLAN to the other as its authentication state changes.

Both ISP and Campus mode are not tied to ports but to a user profile. In other words, if the VSA
Extreme:Extreme-Netlogin-Vlan represents a VLAN different from the one in which the user

currently resides, then VLAN movement will occur after login and after logout. In following example, it is assumed that campus users are connected to ports 4:1-4:4, while ISP users are logged in through ports 1:10-1:14.

NOTE
In the following sample configuration, any lines marked (Default) represent default settings and do not need to be explicitly configured.

ExtremeWare XOS 11.3 Concepts Guide

365

Network Login
create vlan temp create vlan corp configure vlan default delete ports 4:1-4:4 enable ipforwarding # Configuration Information for VLAN temp # No VLAN-ID is associated with VLAN temp. configure vlan temp ipaddress 198.162.32.10 255.255.255.0 # Configuration Information for VLAN corp # No VLAN-ID is associated with VLAN corp. configure vlan corp ipaddress 10.203.0.224 255.255.255.0 configure vlan corp add port 1:10 untagged configure vlan corp add port 1:11 untagged configure vlan corp add port 1:12 untagged configure vlan corp add port 1:13 untagged configure vlan corp add port 1:14 untagged # Network Login Configuration configure vlan temp dhcp-address-range 198.162.32.20 - 198.162.32.80 configure vlan temp dhcp-options default-gateway 198.162.32.1 configure vlan temp dhcp-options dns-server 10.0.1.1 configure vlan temp dhcp-options wins-server 10.0.1.85 configure netlogin vlan temp enable netlogin web-based enable netlogin ports 1:10-1:14,4:1-4:4 web-based configure netlogin base-url "network-access.net" (Default) configure netlogin redirect-page http://www.extremenetworks.com (Default) enable netlogin logout-privilege (Default) disable netlogin session-refresh 3 (Default) # DNS Client Configuration configure dns-client add name-server 10.0.1.1 configure dns-client add name-server 10.0.1.85 #RADIUS Configuration configure radius netlogin primary server 10.0.1.2 1812 client-ip 10.10.20.30 vr VrMgmt configure radius netlogin primary shared-secret purple enable radius

The following example is for the FreeRADIUS server; the configuration might be different for your RADIUS server:
#RADIUS Server Setting (VSAs)(optional) Extreme:Extreme-Netlogin-Only = Enabled (if no CLI authorization) Extreme:Extreme-Netlogin-Vlan = "corp" (destination vlan for CAMPUS mode network login)

NOTE
For information about how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server.

366

ExtremeWare XOS 11.3 Concepts Guide

Web-Based Authentication

Web-Based Authentication User Login


When you use web-based authentication, follow these steps: 1 Set up the Windows IP configuration for DHCP. 2 Plug into the port that has web-based network login enabled. 3 Log in to Windows. 4 Release any old IP settings and renew the DHCP lease. This is done differently depending on the version of Windows the user is running:

Windows 9xUse the winipcfg tool. Choose the Ethernet adapter that is connected to the port on which network login is enabled. Use the buttons to release the IP configuration and renew the DHCP lease. Windows NT/2000/XPUse the ipconfig command line utility. Use the command ipconfig/ release to release the IP configuration and ipconfig/renew to get the temporary IP address from the switch. If you have more than one Ethernet adapter, specify the adapter by using a number for the adapter following the ipconfig command. You can find the adapter number using the command ipconfig/all. NOTE

The idea of explicit release/renew is required to bring the network login client machine in the same subnet as the connected VLAN. When using we-based authentication, this requirement is mandatory after every logout and before login again as the port moves back and forth between the temporary and permanent VLANs.

At this point, the client will have its temporary IP address. In this example, the client should have obtained the an IP address in the range 198.162.32.20 - 198.162.32.80. 5 Bring up the browser and enter any URL as http://www.123.net or http://1.2.3.4 or switch IP address as http://<IP address>/login (where IP address could be either temporary or Permanent VLAN Interface for Campus Mode). URL redirection redirects any URL and IP address to the network login page. This is significant where security matters most, as no knowledge of VLAN interfaces is required to be provided to network login users, as they can login using a URL or IP address. NOTE
URL redirection requires that the switch is configured with a DNS client.

A page opens with a link for Network Login. 6 Click the Network Login link. A dialog box opens requesting a user name and password. 7 Enter the user name and password configured on the RADIUS server. After the user has successfully logged in, the user will be redirected to the URL configured on the RADIUS server. During the user login process, the following takes place:

Authentication is done through the RADIUS server. After successful authentication, the connection information configured on the RADIUS server is returned to the switch:

The permanent VLAN The URL to be redirected to (optional)

ExtremeWare XOS 11.3 Concepts Guide

367

Network Login

The URL description (optional)

The port is moved to the permanent VLAN. You can verify this using the show vlan command. For more information on the show vlan command, see Displaying VLAN Settings on page 230.

After a successful login has been achieved, there are several ways that a port can return to a nonauthenticated, non-forwarding state:

The user successfully logs out using the logout web browser window. The link from the user to the switchs port is lost. There is no activity on the port for 20 minutes. An administrator changes the port state. NOTE

Because network login is sensitive to state changes during the authentication process, Extreme Networks recommends that you do not log out until the login process is complete. The login process is complete when you receive a permanent address.

MAC-Based Authentication
MAC-based authentication is used for supplicants that do not support a network login mode, or supplicants that are not aware of the existence of such security measure, for example an IP phone. If a MAC address is detected on a MAC-Based enabled netlogin port, an authentication request will be sent once to the AAA application. AAA tries to authenticate the MAC address against the configured radius server and its configured parameters (timeout, retries, and so on) or the local database. The credentials used for this are the supplicants MAC address in ASCII representation, and a locally configured password on the switch. If no password is configured, the MAC address is used as the password. You can also group MAC addresses together using a mask. You can configure a MAC list or a table of MAC entries to filter and authenticate clients based on their MAC addresses. If there a match is found in the table of MAC entries, authentication occurs. If no match is found in the table of MAC entries, and a default entry exists, the default will be used to authenticate the client. All entries in the list are automatically sorted in longest prefix order. All passwords are stored and showed encrypted. Beginning with ExtremeWare XOS 11.3, you can associate a MAC address with one or more ports. By learning a MAC address, the port confirms the supplicant before sending an authorization request to the RADIUS server. This additional step protects your network against unauthorized supplicants because the port accepts only authorization requests from the MAC address learned on that port. The port blocks all other requests that do not have a matching entry. This section describes the following topics:

Enabling and Disabling MAC-Based Network Login on page 369 Associating a MAC Address to a Specific Port on page 369 Adding and Deleting MAC Addresses on page 369 Displaying the MAC Address List on page 370

368

ExtremeWare XOS 11.3 Concepts Guide

MAC-Based Authentication

Secure MAC Configuration Example on page 370 MAC-Based Network Login Configuration Example on page 371

Enabling and Disabling MAC-Based Network Login


To enable MAC-based network login on the switch, use the following command:
enable netlogin mac

Any combination of types of authentication can be enabled on the same switch. At least one of the authentication types must be specified on the CLI. To disable MAC-based network login on the switch, use the following command:
disable netlogin mac

To enable MAC-based network login on one or more ports, use the following command:
enable netlogin ports <portlist> mac

Network Login must be disabled on a port before you can delete a VLAN that contains that port. To disable MAC-based network login on one or more ports, use the following command:
disable netlogin ports <portlist> mac

Associating a MAC Address to a Specific Port


You can configure the switch to accept and authenticate a client with a specific MAC address. Only MAC addresses that have a match for the specific ports are sent for authentication. For example, if you associate a MAC address with one or more ports, only authentication requests for that MAC address received on the port(s) are sent to the configured RADIUS server or local database. The port(s) block all other authentication requests that do not have a matching entry. This is also known as secure MAC. To associate a MAC address with one or more ports, specify the ports option when using the following command:
configure netlogin add mac-list [<mac> {<mask>} | default] {encrypted} {<password>} {ports <port_list>}

You must enable MAC-based netlogin on the switch and the specified ports. If MAC-based netlogin is not enabled on the specified port(s), the switch displays a warning message similar to the following:
WARNING: Not all specified ports have MAC-Based NetLogin enabled.

For a sample configuration, see Secure MAC Configuration Example on page 370.

Adding and Deleting MAC Addresses


To add a MAC address to the table, use the following command:
configure netlogin add mac-list [<mac> {<mask>} | default] {encrypted} {<password>} {ports <port_list>}

ExtremeWare XOS 11.3 Concepts Guide

369

Network Login To remove a MAC address from the table, use the following command:
configure netlogin delete mac-list [<mac> {<mask>} | default]

Displaying the MAC Address List


To display the MAC address table, use the following command:
show netlogin mac-list

When a client needs authentication the best match will be used to authenticate to the server. MAC-based authentication is VR aware, so there is one MAC list per VR. Assume we have a supplicant with MAC address 00:04:96:05:40:00, and the switch has the following table:
MAC Address/Mask -------------------00:00:00:00:00:10/48 00:00:00:00:00:11/48 00:00:00:00:00:12/48 00:01:30:70:0C:00/48 00:01:30:32:7D:00/48 00:04:96:00:00:00/24 Password (encrypted) ---------------------<not configured> <not configured> <not configured> yaqu ravdqsr <not configured> Port(s) -------------1:1-1:5 1:6-1:10 any any any any

The user name used to authenticate against the Radius server would be 000496000000, as this is the supplicants MAC address with the configured mask applied. Note that the commands are VR aware, and therefore one MAC list table exists per VR.

Secure MAC Configuration Example


The following configuration example shows how to configure secure MAC on your Extreme Networks switch. To configure secure MAC, do the following:

Create a VLAN used for netlogin Configure the VLAN for netlogin Enable MAC-based netlogin on the switch Enable MAC-based netlogin on the ports used for authentication Specify one or more ports to accept authentication requests from a specific MAC address

In the following example, authentication requests from MAC address:


00:00:00:00:00:10 are only accepted on ports 1:1 through 1:5 00:00:00:00:00:11 are only accepted on ports 1:6 through 1:10 00:00:00:00:00:12 are accepted on all other ports

create vlan nlvlan configure netlogin vlan nlvlan enable netlogin mac enable netlogin ports 1:1-1:10 mac configure netlogin add mac-list 00:00:00:00:00:10 ports 1:1-1:5 configure netlogin add mac-list 00:00:00:00:00:11 ports 1:6-1:10 configure netlogin add mac-list 00:00:00:00:00:12

370

ExtremeWare XOS 11.3 Concepts Guide

Additional Network Login Configuration Details To view your network login configuration, use one of the following commands:

show netlogin {port <portlist> vlan <vlan_name>} {dot1x {detail}} {mac} {webbased} show netlogin mac-list

MAC-Based Network Login Configuration Example


The following configuration example shows the Extreme Networks switch configuration needed to support the MAC-based network login example.
create vlan temp create vlan corp configure vlan default delete ports 4:1-4:4 # Configuration Information for VLAN corp # No VLAN-ID is associated with VLAN corp. configure vlan corp ipaddress 10.203.0.224 255.255.255.0 # Network Login Configuration configure netlogin vlan temp enable netlogin mac enable netlogin ports 4:1-4:4 mac configure netlogin add mac-list default <password> # RADIUS Configuration configure radius netlogin primary server 10.0.1.2 1812 client-ip 10.10.20.30 vr VRMgmt configure radius netlogin primary shared-secret purple enable radius

The following example is for the FreeRADIUS server; the configuration might be different for your RADIUS server:
#RADIUS Server Setting 00E018A8C540 Auth-Type := Local, User-Password == "00E018A8C540"

NOTE
For information about how to use and configure your RADIUS server, please refer to the documentation that came with your RADIUS server

Additional Network Login Configuration Details


This section describes how to configure netlogin MAC-based VLANs on the BlackDiamond 8800 family of switches and the Summit X450 switch. Please review the earlier sections of this chapter for general information about network login and information about MAC-based, web-based, and 802.1x authentication methods.

ExtremeWare XOS 11.3 Concepts Guide

371

Network Login

Configuring Netlogin MAC-Based VLANsBlackDiamond 8800 Family of Switches and the Summit X450 Switch Only
Currently, network login allows only a single, untagged VLAN to exist on a port. This limits the flexibility for untagged supplicants because they must be in the same VLAN. Beginning with ExtremeWare XOS 11.3, the BlackDiamond 8800 family of switches and the Summit X450 switch support netlogin MAC-based VLANs. Netlogin MAC-based VLANs allow a port assigned to a VLAN to operate in a MAC-based fashion. This means that each individual untagged supplicant, identified by its MAC address, can be in different VLANs. Netlogin MAC-based VLAN utilizes VSA information from both the netlogin local database and the RADIUS server. After successfully performing the Campus mode of operation, the supplicant is added untagged to the destination VLAN. To support this feature, you must configure the netlogin ports mode of operation. The following sections describe the following topics:

Netlogin MAC-Based VLANs Rules and Restrictions on page 372 Configuring the Port Mode on page 372 Displaying Netlogin MAC-Based VLAN Information on page 373 Netlogin MAC-Based VLAN Example on page 373

Netlogin MAC-Based VLANs Rules and Restrictions


This section summarizes the rules and restrictions for configuring netlogin MAC-based VLANs:

You must configure and enable netlogin on the switch and before you configure netlogin MAC-based VLANs. If you attempt to configure the ports mode of operation before enabling netlogin, the switch displays an error message similar to the following:
ERROR: The following ports do not have NetLogin enabled; 1

10 Gigabit Ethernet ports such as those on the 10G4X I/O module and the uplink ports on the Summit X450 switch do not support netlogin MAC-based VLANs. If you attempt to configure netlogin MAC-based VLANs on 10 Gigabit Ethernet ports, the switch displays an error message similar to the following:
ERROR: The following ports do not support the MAC-Based VLAN mode; 1, 2, 10

You can have a maximum of 1,024 MAC addresses per I/O module or per Summit X450 switch.

Configuring the Port Mode


To support netlogin MAC-based VLANs on a netlogin port, you must configure that ports mode of operation. To specify MAC-based operation, use the following command and specify mac-based-vlans:
configure netlogin ports [all | <port_list>] mode [mac-based-vlans | port-based-vlans]

By default, the netlogin ports mode of operation is port-based-vlans. If you modify the mode of operation to mac-based-vlans and later disable all netlogin protocols on that port, the mode of operation automatically returns to port-based-vlans.

372

ExtremeWare XOS 11.3 Concepts Guide

Additional Network Login Configuration Details When you change the netlogin ports mode of operation, the switch deletes all currently known supplicants from the port and restores all VLANs associated with that port to their original state. In addition, by selecting mac-based-vlans, you are unable to manually add or delete untagged VLANs from this port. Netlogin now controls these VLANs. With netlogin MAC-based operation, every authenticated client has an additional FDB flag that indicates a translation MAC address. If the supplicants requested VLAN does not exist on the port, the switch adds the requested VLAN.

Displaying Netlogin MAC-Based VLAN Information


The following commands display important information for netlogin MAC-based VLANs. FDB Information. To view FDB entries, use the following command:
show fdb netlogin [all | mac-based-vlans]

By specifying netlogin, you see only FDB entries related to netlogin or netlogin MAC-based VLANs. The flags associated with netlogin include:

vIndicates the FDB entry was added because the port is part of a MAC-Based virtual port/VLAN combination. nIndicates the FDB entry was added by network login.

VLAN and Port Information. To view the VLANs that netlogin adds temporarily in MAC-based mode, use the following command:
show ports <port_list> information detail

By specifying information and detail, the output displays the temporarily added VLANs in netlogin MAC-based mode. To confirm this, review the following output of this command:

VLAN cfgThe term MAC-based appears next to the tag number. Netlogin port modeThis output was added to display the port mode of operation. Mac based appears and the network login port mode of operation.

To view information about the ports that are temporarily added in MAC-based mode for netlogin, due to discovered MAC addresses, use the following command:
show vlan detail

By specifying detail, the output displays detailed information including the ports associated with the VLAN. The flags associated with netlogin include:

aIndicates an authenticated network login port. uIndicates an unauthenticated network login port. mIndicates that the netlogin port operates in MAC-based mode.

Netlogin MAC-Based VLAN Example


The following example configures the netlogin MAC-based VLAN feature:
create vlan users12 create vlan nlvlan configure netlogin vlan nlvlan enable netlogin mac

ExtremeWare XOS 11.3 Concepts Guide

373

Network Login
enable netlogin ports 1:1-1:10 mac configure netlogin ports 1:1-1:10 mode mac-based-vlans configure netlogin add mac-list default MySecretPassword

Expanding upon the previous example, you can also utilize the local database for authentication rather than the RADIUS server:
create netlogin local-user 000000000012 vlan-vsa untagged default create netlogin local-user 000000000010 vlan-vsa untagged users12

For more information about local database authentication, see Configuring Local Database Authentication on page 355.

374

ExtremeWare XOS 11.3 Concepts Guide

18 CLEAR-Flow
This chapter describes the following topics:

Overview on page 375 Configuring CLEAR-Flow on page 375 Adding CLEAR-Flow Rules to ACLs on page 376 CLEAR-Flow Rule Examples on page 389

Overview
CLEAR-Flow is a broad framework for implementing security, monitoring, and anomaly detection in ExtremeWare XOS software. Instead of simply looking at the source and destination of traffic, CLEARFlow allows you to specify certain types of traffic that require more attention. Once certain criteria for this traffic are met, the switch can either take an immediate, pre-determined action, or send a copy of the traffic off-switch for analysis. CLEAR-Flow is an extension to Access Control Lists (ACLs). You create ACL policy rules to count packets of interest. CLEAR-Flow rules are added to the policy to monitor these ACL counter statistics. The CLEAR-Flow agent monitors the counters for the situations of interest to you and your network. You can monitor the cumulative value of a counter, the change to a counter over a sampling interval, the ratio of two counters, or even the ratio of the changes of two counters over an interval. For example, you can monitor the ratio between TCP SYN and TCP packets. An abnormally large ratio may indicate a SYN attack. The counters used in CLEAR-Flow are either defined by you in an ACL entry, or can be a predefined counter. See the section Predefined CLEAR-Flow Counters for a list and description of these counters. If the rule conditions are met, the CLEAR-Flow actions configured in the rule are executed. The switch can respond by modifying an ACL that will block, prioritize, or mirror the traffic, executing a set of CLI commands, or sending a report using a SNMP trap or EMS log message. NOTE
CLEAR-Flow is available only on the BlackDiamond 10K family of switches.

Configuring CLEAR-Flow
CLEAR-Flow is an extension to ACLs, so you must be familiar with configuring ACLs before you add CLEAR-Flow rules to your ACL policies. Creating ACLs is described in detail in Chapter 13, Access Lists (ACLs). Chapter 13 describes how to create ACL policies, the syntax of an ACL policy file, and how to apply ACL policies to the switch. In this current chapter, you will find information about the CLEAR-Flow rules that you add to ACL policies, including the CLEAR-Flow rules syntax and behavior.

ExtremeWare XOS 11.3 Concepts Guide

375

CLEAR-Flow After creating the ACLs that contain CLEAR-Flow rules, and after applying the ACLs to the appropriate interface, you will enable CLEAR-Flow on the switch. When CLEAR-Flow is enabled, the rules will be evaluated by the CLEAR-Flow agent on the switch, and if any rules are triggered, the CLEAR-Flow actions are executed. To enable CLEAR-Flow, use the following command:
enable clear-flow

When you disable the CLEAR-Flow agent on the switch, CLEAR-Flow sampling stops, and all rules are left in the current state. To disable CLEAR-Flow, use the following command:
disable clear-flow

NOTE
Any actions triggered while CLEAR-Flow is enabled will continue when CLEAR-Flow is disabled, unless explicitly stopped.

Displaying CLEAR-Flow Configuration and Activity


To display the state of the CLEAR-Flow agent, any CLEAR-Flow policies on each interface, and the number of CLEAR-Flow rules, use the following command:
show clear-flow

To display the CLEAR-Flow rules and configuration, use the following command:
show clear-flow [port <port> | vlan <vlanname> | any] {rule <rulename>} {detail}

Or to display all the rules, use the following command:


show clear-flow rule-all

When CLEAR-Flow is enabled, any rules that satisfy the threshold will trigger and take action. To display the CLEAR-Flow rules that have been triggered, use the following command:
show clear-flow rule-triggered

To display which ACLs have been modified by CLEAR-Flow rules, use the following command:
show clear-flow acl-modified

Adding CLEAR-Flow Rules to ACLs


As described in the chapter about ACLs, each ACL policy file consists of a number of named entries. Each entry consists of match conditions and actions to take if the entry is matched. CLEAR-Flow builds on the ACL concept to include rules that are periodically checked, and actions to take if a rule is triggered. The CLEAR-Flow entries are similar to the ACL entries. The syntax of a CLEAR-Flow rule entry is:
entry <CLFrulename> <match-type> { if { <match-conditions>;

376

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs


} then { <actions>; } }

Or you can specify an optional else clause:


entry <CLFrulename> <match-type> { if { <match-conditions>; } then { <actions>; } else { <actions>; } }

In the CLEAR-Flow rule syntax, the <CLFrulename> is the name of the rule (maximum of 31 characters). The <match-type> specifies whether the rule is triggered when any of the expressions that make up the conditions are true (logical OR), or only when all of the expressions are true (logical AND). The <match-type> is an optional element. The <match-conditions> specifies the conditions that will trigger the rule, and how often to evaluate the rule. The <actions> in the then clause is the list of actions to take when the rule is triggered, and the optional else clause <actions> is the list of actions to take after the rule is triggered, and when the <match-conditions> later become false.

NOTE
When you create an ACL policy file that contains CLEAR-Flow rules, the CLEAR-Flow rules do not have any precedence, unlike the ACL entries. Each CLEAR-Flow rule specifies how often it should be evaluated. The order of evaluation depends on the sampling time and when the CLEAR-Flow agent receives the counter statistics. The order of the CLEAR-Flow rules in the policy file does not have any significance.

The rule match type, rule match conditions, and rule actions are discussed in these sections:

CLEAR-Flow Rule Match Type on page 377 CLEAR-Flow Rule Match Conditions on page 378 CLEAR-Flow Rule Actions on page 384

CLEAR-Flow Rule Match Type


The match type is optional. There are two possible choices for the match type:

match allAll the match expressions must be true for a match to occur. This is the default. match anyIf any match expression is true, then a match occurs. NOTE

The match type was first available for CLEAR-Flow in ExtremeWare XOS 11.2.

ExtremeWare XOS 11.3 Concepts Guide

377

CLEAR-Flow

CLEAR-Flow Rule Match Conditions


In a CLEAR-Flow rule, the <match-conditions> portion consists of one to four expressions, an optional global-rule statement, and an optional period statement:
entry <CLFrulename> <match-type> { if { <expression>; <expression>; <expression>; <expression>; global-rule; period <interval>; } then { <actions>; } else { <actions>; } }

In the following example, the CLEAR-Flow rule cflow_count_rule_example will be evaluated every ten seconds. The actions statements will be triggered if the value of counter1 (defined earlier in the ACL policy file) is greater than 1,000,000:
entry cflow_count_rule_example { if { count counter1 > 1000000 ; period 10 ; } then { <actions>; } }

The global-rule statement is optional and affects how the counters are treated. An ACL that defines counters can be applied to more than one interface. In the original release of CLEAR-Flow, however, any counters used in an expression were only evaluated for that particular interface that the CLEAR-Flow rule was applied to. Beginning with the ExtremeWare XOS 11.2 release, you can specify the global-rule statement so that counters are evaluated for all the applied interfaces. For example, if a policy that defines a counter is applied to port 1:1 and 2:1, a CLEAR-Flow rule that used the global-rule statement would sum up the counts from both ports. Without the global-rule statement, the CLEAR-Flow rule would only look at the counts received on one port at a time. The period <interval> statement is optional and sets the sampling interval, in seconds. This statement specifies how often the rule is evaluated by the CLEAR-Flow agent. If not specified, the default value is 5 seconds.

NOTE
In ExtremeWare XOS 11.1 only one expression was allowed per CLEAR-Flow rule.

There are five CLEAR-Flow rule expressions: count, delta, ratio, delta-ratio, and rule. All of these expressions check the values of counters to evaluate if an action should be taken. The counters are either defined in the ACL entries that are defined on the switch, or are the pre-defined CLEAR-Flow

378

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs counters. When you use a counter statement in an ACL, you are defining the counter used by CLEARFlow to monitor your system. The following sections discuss the CLEAR-Flow rule expressions in detail:

Count Expression on page 379 Delta Expression on page 380 Ratio Expression on page 381 Delta-Ratio Expression on page 382 Rule-True-Count Expression on page 383

Count Expression
A CLEAR-Flow count expression compares a counter with the threshold value. The following is the syntax for a CLEAR-Flow count expression:
count <counterName> REL_OPER <countThreshold> ;

The count statement specifies how to compare a counter with its threshold. The <counterName> is the name of an ACL counter referred to by an ACL rule entry and the <countThreshold> is the value compared with the counter. The REL_OPER is selected from the relational operators for greater than, great than or equal to, less than, or less than or equal to (>, >=, <, <=). Here is an example of a count expression used in a CLEAR-Flow rule:
entry cflow_count_rule_example { if { count counter1 > 1000000 ; period 10 ; } then { <actions>; } }

The actions will be discussed in the section, CLEAR-Flow Rule Actions on page 384. In Table 51 is an example of evaluating the CLEAR-Flow count expression above multiple times. Notice that the rule is not triggered until evaluation 3, when the value of the counter is greater than 1,000,000.

Table 51: Count Expression Evaluation Example


Evaluation 1 2 3 4 counter1 value 384625 769250 1153875 1538500 Rule triggered? No No Yes Yes

See the section, Count Expression Example on page 389, for a full example of an ACL and a CLEARFlow rule using a count expression.

ExtremeWare XOS 11.3 Concepts Guide

379

CLEAR-Flow

Delta Expression
A CLEAR-Flow delta expression computes the difference from one sample to the next of a counter value. This difference is compared with the threshold value. The following is the syntax for a CLEARFlow delta expression:
delta <counterName> REL_OPER <countThreshold> ; hysteresis <hysteresis> ;

The delta expression specifies how to compare the difference in a counter value from one sample to the next with its threshold. The <counterName> is the name of an ACL counter referred to by an ACL rule entry and the <countThreshold> is the value compared with the difference in the counter from one sample to the next. The REL_OPER is selected from the relational operators for greater than, great than or equal to, less than, or less than or equal to (>, >=, <, <=). The hysteresis <hysteresis> statement is optional, and sets a hysteresis value for the threshold. After the delta statement is true, the value of the threshold is adjusted so that a change smaller than the hysteresis value will not cause the statement to become false. For statements using the REL_OPER > or >=, the hysteresis value is subtracted from the threshold; for < or <=, the hysteresis value is added to the threshold. For example, the following delta expression:
delta counter1 >= 100 ; hysteresis 10 ;

will only be true after the delta of the counter reaches at least 100. At the time it becomes true, the hysteresis value is subtracted from the threshold (setting the threshold to 90). With the threshold now at 90, the condition would stay true until the delta of the counter becomes less than 90. If the expression becomes false, the threshold is reset to its original value. You would use the hysteresis value to prevent the expression from vacillating between the true and false states if the difference between the counter values is near the threshold. If the hysteresis value is greater than the threshold value, the hysteresis value will be set to zero. In Table 52 is an example of evaluating the CLEAR-Flow delta expression above multiple times. Notice that the rule is not triggered until evaluation 4, when the delta value (the change in the counter value from one evaluation to the next) is greater than or equal to 100. Once the rule is triggered, it remains triggered until the delta value is less than 90 (the original threshold minus the hysteresis), at evaluation 7. At evaluation 9, the rule is again triggered when the delta reaches 100. The rule will remain triggered until the delta drops below 90.

Table 52: Delta Expression Evaluation Example


Evaluation 1 2 3 4 5 6 7 8 9 counter1 value 397 467 547 657 757 852 932 1031 1131 Delta value N/A 70 80 110 100 95 80 99 100 Rule triggered? No No No Yes Yes Yes No No Yes

380

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs

Table 52: Delta Expression Evaluation Example (Continued)


Evaluation 10 counter1 value 1230 Delta value 99 Rule triggered? Yes

See the section, Delta Expression Example on page 389, for a full example of an ACL and a CLEARFlow rule using a delta expression.

Ratio Expression
A CLEAR-Flow ratio expression compares the ratio of two counter values with the threshold value. The following is the syntax for a CLEAR-Flow ratio expression:
ratio <counterNameA> <counterNameB> REL_OPER <countThreshold> ; min-value <min-value> ; hysteresis <hysteresis> ;

The ratio statement specifies how to compare the ratio of two counters with its threshold. The value of <counterNameA> is divided by the value of <counterNameB>, to compute the ratio. That ratio is compared with the <countThreshold>. The REL_OPER is selected from the relational operators for greater than, great than or equal to, less than, or less than or equal to (>, >=, <, <=). The min-value statement is optional, and sets a minimum value for the counters. If either counter is less than the minimum value, the expression evaluates to false. If not specified, the minimum value is 1. The hysteresis <hysteresis> statement is optional, and sets a hysteresis value for the threshold. After the ratio statement is true, the value of the threshold is adjusted so that a change smaller than the hysteresis value will not cause the statement to become false. For statements using the REL_OPER > or >=, the hysteresis value is subtracted from the threshold; for < or <=, the hysteresis value is added to the threshold. For example, the following ratio expression:
ratio counter1 counter2 >= 5 ; min-value 100; hysteresis 1 ;

will only be true after the ratio of the counters reached at least 5 and the counter values are at least 100. At the time it became true, the hysteresis value would be subtracted from the threshold (setting the threshold to 4). With the threshold now at 4, the condition would stay true until the ratio of the counters became less than 4. If the statement becomes false, the threshold is reset to its original value. You would use the hysteresis value to prevent the rule from vacillating between the true and false states if the ratio between the counter values is near the threshold. If the hysteresis value is greater than the threshold value, the hysteresis value will be set to zero. In Table 53 is an example of evaluating the CLEAR-Flow ratio expression above multiple times. Notice that the rule is not triggered at the first evaluation because both counters have not yet reached the minvalue of 100. The rule first triggers at evaluation 3, when ratio of the two counters exceeds 5. Once the rule is triggered, it remains triggered until the ratio value is less than 4 (the original threshold minus the hysteresis), at evaluation 5. At evaluation 7, the rule is again triggered when the ratio reaches 5. The rule will remain triggered until the ratio drops below 4.

ExtremeWare XOS 11.3 Concepts Guide

381

CLEAR-Flow

Table 53: Ratio Expression Evaluation Example


Evaluation 1 2 3 4 5 6 7 counter1 value 427 941 2475 2308 2313 3597 5340 counter2 value 70 235 412 570 771 899 1065 ratio 6 4 6 4 3 4 5 Rule triggered? No No Yes Yes No No Yes

See the section, Ratio Expression Example on page 390, for a full example of an ACL and a CLEARFlow rule using a ratio expression.

Delta-Ratio Expression
A CLEAR-Flow delta-ratio expression is a combination of the delta and ratio expressions. The CLEARFlow agent computes the difference from one sample to the next for each of the two counters. The ratio of the differences is then compared to the threshold value. The following is the syntax for a CLEARFlow delta-ratio expression (note the similarity to the delta expression):
delta-ratio <counterNameA> <counterNameB> REL_OPER <countThreshold> ; min-value <min-value> ; hysteresis <hysteresis> ;

The delta-ratio statement specifies how to compare the ratio of the counter differences with its threshold. The difference of the sample values of <counterNameA> is divided by the difference of the sample values of <counterNameB>, to compute the ratio that is compared with the <countThreshold>. The REL_OPER is selected from the relational operators for greater than, great than or equal to, less than, or less than or equal to (>, >=, <, <=). The min-value statement is optional, and sets a minimum value for the counters. If either counter is less than the minimum value, the expression evaluates to false. If not specified, the minimum value is 1. The hysteresis <hysteresis> statement is optional, and sets a hysteresis value for the threshold. After the ratio statement is true, the value of the threshold is adjusted so that a change smaller than the hysteresis value will not cause the statement to become false. For statements using the REL_OPER > or >=, the hysteresis value is subtracted from the threshold; for < or <=, the hysteresis value is added to the threshold. For example, the following delta-ratio expression:
delta-ratio counter1 counter2 >= 5 ; min-value 100 ; hysteresis 1 ;

will only be true after the ratio of the deltas of the counters reached at least 5. At the time it became true, the hysteresis value would be subtracted from the threshold (setting the threshold to 4). With the threshold now at 4, the condition would stay true until the ratio of the deltas of the counters became less than 4. If the statement becomes false, the threshold is reset to its original value. You would use the hysteresis value to prevent the rule from vacillating between the true and false states if the ratio of the deltas of

382

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs the counters is near the threshold. If the hysteresis value is greater than the threshold value, the hysteresis value will be set to zero. In Table 54 is an example of evaluating the CLEAR-Flow delta-ratio expression above multiple times. Notice that the rule is not triggered at the second evaluation because both counters have not yet reached the min-value of 100. The rule first triggers at evaluation 4, when ratio of the two counters exceeds 5. Once the rule is triggered, it remains triggered until the ratio value is less than 4 (the original threshold minus the hysteresis), at evaluation 6. At evaluation 8, the rule is again triggered when the ratio reaches 5. The rule will remain triggered until the ratio drops below 4.

Table 54: Delta-Ratio Expression Evaluation Example


Evaluation 1 2 3 4 5 6 7 8 counter1 value 110 537 1478 3953 6261 8574 12171 17511 counter1 delta N/A 427 941 2475 2308 2313 3597 5340 counter2 value 20 90 325 737 1307 2078 2977 4042 counter2 delta N/A 70 235 412 570 771 899 1065 Ratio N/A 6 4 6 4 3 4 5 Rule triggered? No No No Yes Yes No No Yes

See the section, Delta-Ratio Expression Example on page 392, for a full example of an ACL and a CLEAR-Flow rule using a delta-ratio expression.

Rule-True-Count Expression
A CLEAR-Flow rule-true-count expression compares how many times a CLEAR-Flow rule is true with a threshold value. One use is to combine multiple rules together into a complex rule. The following is the syntax for a CLEAR-Flow rule-true-count expression:
rule-true-count <ruleName> REL_OPER <countThreshold> ;

The rule-true-count statement specifies how to compare how many times a CLEAR-Flow rule is true with the expression threshold. The <ruleName> is the name of the CLEAR-Flow rule to monitor and the <countThreshold> is the value compared with the number of times the rule is true. The REL_OPER is selected from the relational operators for greater than, great than or equal to, less than, or less than or equal to (>, >=, <, <=). For example, the following delta-ratio expression:
rule-true-count cflow_count_rule_example >= 5 ;

will only be true after the CLEAR-Flow rule cflow_count_rule_example has been true at least five times. If the rule cflow_count_rule_example becomes true and remains true, and the period for cflow_count_rule_example is the default five seconds, the rule would have to be true for at least 20 seconds before the rule-true-count expression will become true. If the period of the rule cflow_count_rule_example is 10 seconds, it will need to be true for at least 40 seconds before the ruletrue_count expression becomes true.

ExtremeWare XOS 11.3 Concepts Guide

383

CLEAR-Flow

CLEAR-Flow Rule Actions


CLEAR-Flow rules specify an action to take when the rule is triggered and can optionally specify an action to take when the expression is false. Because more than one action can be taken in a single rule, the collection of actions is referred to as an action list. The actions that can be taken are:

Permit/Deny QoS Profile Mirror SNMP Trap Syslog CLI

Additionally, the SNMP trap, syslog, and CLI rule actions can use keyword substitution to make the rule actions more flexible. The keyword substitutions are described at the end of the rule action descriptions. See the section, Keyword Substitution on page 385, for more information. The following sections describe the different rule actions.

Permit/Deny
This action modifies an existing ACL rule to permit or block traffic that matches that rule. To change an ACL to permit, use the following syntax:
permit <ACLRuleName>

To change an ACL to deny, use the following syntax:


deny <ACLRuleName>

QoS Profile
This action modifies an existing ACL rule to set the QoS profile for traffic that matches that rule. To change the ACL to forward to QoS profile <QPx>, use the following syntax:
qosprofile <ACLRuleName> <QPx>

For example:
qosprofile acl_rule_1 QP3

Mirror
This action modifies an existing ACL rule to mirror traffic that matches that rule, or to stop mirroring that traffic. The mirroring port must be enabled when mirroring on an ACL rule is turned on. This could be configured earlier, or use the CLI action to execute CLI commands to configure mirroring at the same time. To change the ACL to mirror traffic, use the following syntax:
mirror [add|delete] <ACLRuleName>

384

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs For example (enabling mirroring from within CLEAR-Flow rule):
cli enable mirroring to port 7:4 tagged mirror add acl_rule_1

SNMP Trap
This action sends an SNMP trap message to the trap server, with a configurable ID and message string, when the rule is triggered. The message is sent periodically with interval <period> seconds. If <period> is zero, or if this optional parameter is not present, the message is sent only once when the rule is triggered. The interval must be a multiple of the rule sampling/evaluation interval, or the value will be rounded down to a multiple of the rule sampling/evaluation interval. To send an SNMP trap, use the following syntax:
snmptrap <id> <message> <period>

Syslog
This action sends log messages to the ExtremeWare XOS EMS sever. The possible values for message level are: DEBU, INFO, NOTI, WARN, ERRO, and CRIT. The message is sent periodically with interval <period> seconds. If <period> is zero, or if this optional parameter is not present, the message is sent only once when the rule is triggered. The interval must be a multiple of the rule sampling/evaluation interval, or the value will be rounded down to a multiple of the rule sampling/evaluation interval. The messages are logged on both MSMs, so if the backup log is sent to the primary MSM, then the primary MSM will have duplicate log messages. To send a log message, use the following syntax:
syslog <message> <level> <period>

CLI
This action executes a CLI command. There is no authentication or checking the validity of each command. If a command fails, the CLI will log a message in the EMS log. To execute a CLI command, use the following syntax:
cli <cliCommand>

where <cliCommand> is a quoted string.

Keyword Substitution
To make the SNMP trap, syslog, and CLI actions more flexible, keyword substitutions are supported in the syslog and SNMP trap message strings, as well as in the CLI command strings. Table 55 lists the keywords and their substitutions.

ExtremeWare XOS 11.3 Concepts Guide

385

CLEAR-Flow If a keyword is not supported, or a counter name is not found, a string of unknownKeyword[$keyword] will be substituted For the $vlanName and $port keyword, the keyword all will be substituted for those rules in the wildcard ACL Some CLI commands do not support the all keyword, so caution must be used with CLI commands that use this feature. A maximum of 10 different counter substitutions can be used per rule, including counters used in expressions. For example, if a rule uses four counters in its expressions, then we can use six more different counters in keyword substitutions, for a total of 10.

Table 55: Keyword Substitutions


Keyword $policyName $ruleName $<counterName> $ruleValue $ruleThreshold $ruleInterval $vlanName $port Substitution Replace with the policy name. Replace with the CLEAR-Flow rule name. Replace with counter value for the indicated counter name. Replace with the current expression value. Replace with the expression threshold value. Replace with the rule sampling/evaluation interval. Replace with the interface VLAN name. Replace with the interface port number.

Predefined CLEAR-Flow Counters


There are a number of packet statistics gathered by the XOS kernel. In order to allow you to use these statistics in CLEAR-Flow expressions, these kernel counters are now available for use with CLEARFlow. Most of the counter names are based directly on well known names from common kernel structures and MIBs. The names are modified from their familiar form by prepending the characters sys_ to the counter names.

Table 56: Predefined CLEAR-Flow Counters


Counter Name sys_IpInReceives sys_IpInHdrErrors Description1 The total number of input IP packets received from interfaces, including those received in error. The number of input IP packets discarded due to errors in their IP headers, including bad checksums, version number mismatch, other format errors, timeto-live exceeded, errors discovered in processing their IP options, etc. The number of input IP packets discarded because the IP address in their IP header's destination field was not a valid address to be received at this entity. This count includes invalid addresses (e.g., 0.0.0.0) and addresses of unsupported Classes (e.g., Class E). The number of input IP packets for which this entity was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. The number of locally-addressed IP packets received successfully but discarded because of an unknown or unsupported protocol.

sys_IpInAddrErrors

sys_IpForwDatagrams

sys_IpInUnknownProtos

386

ExtremeWare XOS 11.3 Concepts Guide

Adding CLEAR-Flow Rules to ACLs

Table 56: Predefined CLEAR-Flow Counters (Continued)


Counter Name sys_IpInDiscards Description1 The number of input IP packets for which no problems were encountered to prevent their continued processing, but which were discarded (e.g., for lack of buffer space). Note that this counter does not include any IP packets discarded while awaiting re-assembly. The total number of input IP packets successfully delivered to IP user-protocols (including ICMP). The total number of IP packets which local IP user-protocols (including ICMP) supplied to IP in requests for transmission. Note that this counter does not include any IP packets counted in ipForwDatagrams. The number of output IP packets for which no problem was encountered to prevent their transmission to their destination, but which were discarded (e.g., for lack of buffer space). Note that this counter would include IP packets counted in ipForwDatagrams if any such packets met this (discretionary) discard criterion. The number of IP packets discarded because no route could be found to transmit them to their destination. Note that this counter includes any packets counted in ipForwDatagrams which meet this `no-route' criterion. The maximum number of seconds which received fragments are held while they are awaiting reassembly at this entity. The number of IP fragments received which needed to be reassembled at this entity. The number of IP packets successfully re-assembled. The number of failures detected by the IP re-assembly algorithm (for whatever reason: timed out, errors, etc.). Note that this is not necessarily a count of discarded IP fragments since some algorithms (notably the algorithm in RFC 815) can lose track of the number of fragments by combining them as they are received. The number of IP packets that have been successfully fragmented at this entity. The number of IP packets that have been discarded because they needed to be fragmented at this entity but could not be, e.g., because their Don't Fragment flag was set. The number of IP packet fragments that have been generated as a result of fragmentation at this entity. The total number of ICMP messages which the entity received. Note that this counter includes all those counted by icmpInErrors. The number of ICMP messages which the entity received but determined as having ICMP-specific errors (bad ICMP checksums, bad length, etc.). The number of ICMP Destination Unreachable messages received. The number of ICMP Time Exceeded messages received. The number of ICMP Parameter Problem messages received. The number of ICMP Source Quench messages received. The number of ICMP Redirect messages received. The number of ICMP Echo (request) messages received. The number of ICMP Echo Reply messages received. he number of ICMP Timestamp (request) messages received. The number of ICMP Timestamp Reply messages received. The number of ICMP Address Mask Request messages received.

sys_IpInDelivers sys_IpOutRequests

sys_IpOutDiscards

sys_IpOutNoRoutes

sys_IpReasmTimeout sys_IpReasmReqds sys_IpReasmOKs sys_IpReasmFails

sys_IpFragOKs sys_IpFragFails

sys_IpFragCreates

sys_IcmpInMsgs sys_IcmpInErrors sys_IcmpInDestUnreachs sys_IcmpInTimeExcds sys_IcmpInParmProbs sys_IcmpInSrcQuenchs sys_IcmpInRedirects sys_IcmpInEchos sys_IcmpInEchoReps sys_IcmpInTimestamps sys_IcmpInTimestampReps sys_IcmpInAddrMasks

ExtremeWare XOS 11.3 Concepts Guide

387

CLEAR-Flow

Table 56: Predefined CLEAR-Flow Counters (Continued)


Counter Name sys_IcmpInAddrMaskReps sys_IcmpOutMsgs sys_IcmpOutErrors Description1 The number of ICMP Address Mask Reply messages received. The total number of ICMP messages which this entity attempted to send. Note that this counter includes all those counted by icmpOutErrors. The number of ICMP messages which this entity did not send due to problems discovered within ICMP such as a lack of buffers. This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram. In some implementations there may be no types of error which contribute to this counter's value.

sys_IcmpOutDestUnreachs sys_IcmpOutTimeExcds sys_IcmpOutParmProbs sys_IcmpOutSrcQuenchs sys_IcmpOutRedirects sys_IcmpOutEchos sys_IcmpOutEchoReps sys_IcmpOutTimestamps sys_IcmpOutTimestampReps sys_IcmpOutAddrMasks sys_IcmpOutAddrMaskReps sys_IcmpInProtoUnreachs

The number of ICMP Destination Unreachable messages sent. The number of ICMP Time Exceeded messages sent. The number of ICMP Parameter Problem messages sent. The number of ICMP Source Quench messages sent. The number of ICMP Redirect messages sent. The number of ICMP Echo (request) messages sent. The number of ICMP Echo Reply messages sent. The number of ICMP Timestamp (request) messages sent. The number of ICMP Timestamp Reply messages sent. The number of ICMP Address Mask Request messages sent. The number of ICMP Address Mask Reply messages sent. The number of incoming ICMP packets addressed to a not-in-use/unreachable/ invalid protocol. This message is in the general category of ICMP destination unreachable error messages. The number of incoming bad ICMP length packets.2 The number of incoming ICMP packets with a bad code field value. The number of incoming short ICMP packets. The number of incoming ICMP packets with bad checksums. The number of incoming ICMP router advertisements. Router advertisements are used by IP hosts to discover addresses of neighboring routers. The number of outgoing ICMP packets addressed to a not-in-use/unreachable/ invalid protocol. This message is in the general category of ICMP destination unreachable error messages. The number of outgoing ICMP router advertisements. Router advertisements are used by IP hosts to discover addresses of neighboring routers. The number of Host Membership Query messages that have been received on this interface. The number of Host Membership Report messages that have been received on this interface for this group address. The number of incoming IGMP leave requests. The number of incoming IGMP errors. The number of Host Membership Query messages that have been sent on this interface The number of Host Membership Report messages that have been sent on this interface for this group address.

sys_IcmpInBadLen sys_IcmpInBadCode sys_IcmpInTooShort sys_IcmpInBadChksum sys_IcmpInRouterAdv sys_IcmpOutProtoUnreachs

sys_IcmpOutRouterAdv

sys_IgmpInQueries sys_IgmpInReports sys_IgmpInLeaves sys_IgmpInErrors sys_IgmpOutQueries sys_IgmpOutReports

388

ExtremeWare XOS 11.3 Concepts Guide

CLEAR-Flow Rule Examples

Table 56: Predefined CLEAR-Flow Counters (Continued)


Counter Name sys_IgmpOutLeaves Description1 The number of outgoing IGMP leave requests.

1.Most of these descriptions can be found in RFC 2011, SNMPv2 Management Information Base for the Internet Protocol using SMIv2 2.The length of an ICMP packet depends on the type and code field.

CLEAR-Flow Rule Examples


In the examples that follow, there are one to two ACL rule entries followed by a CLEAR-Flow rule entry. The examples illustrate the four CLEAR-Flow rule expressions: count, delta, ratio, and delta-ratio.

Count Expression Example


In the following example, every 10 seconds the CLEAR-Flow agent will request the counter1 statistics from the hardware. After it receives the counter value, it will evaluate the CLEAR-Flow rule. If the value of counter1 is greater than 1000000 packets, the CLEAR-Flow agent will send a trap message to the SNMP master, and change the ACL acl_rule1 to block traffic (acl_rule1 is modified to a deny rule). Since there is no period configured for the snmptrap statement, the message is sent only once.
entry acl_rule1 { if { destination-address 192.168.16.0/24; destination-port 2049; protocol tcp; } then { count counter1; } } entry cflow_count_rule_example { if { count counter1 > 1000000 ; period 10 ; } then { snmptrap 123 "Traffic on acl_rule1 exceeds threshold"; deny acl_rule1; } }

Delta Expression Example


In this example, every 10 seconds the CLEAR-Flow agent will request the counter1 statistics from the hardware. After it receives the counter value, it will then evaluate the rule. If the delta (change) of the counter1 value from the last sampled value 10 seconds ago is greater than or equal to 1000 packets, the CLEAR-Flow agent will send a trap message to the SNMP master, and change the ACL acl_rule1 to

ExtremeWare XOS 11.3 Concepts Guide

389

CLEAR-Flow move the traffic to QP3. In addition, reduce the peak rate to 5 Kbps on QP3. As long as the delta continues to be greater than or equal to 1000 packets, the CLEAR-Flow agent will repeatedly send a trap message every 120 seconds. Once the delta falls below the threshold, the agent will execute the two actions in the else portion; it will send a single SNMP trap message, return the traffic to QP1, and reset QP3 to its original bandwidth.
entry acl_rule1 { if { destination-address 192.168.16.0/24; destination-port 2049; protocol tcp; } then { count counter1; } } entry cflow_delta_rule_example { if { delta counter1 >= 100000 ; period 10 ; } then { snmptrap 123 "Traffic to 192.168.16.0/24 exceed rate limit" 120; qosprofile acl_rule1 QP3; cli "configure qosprofile qp3 peak_rate 5 K ports all" ; } else { snmptrap 123 "Traffic to 192.168.16.0/24 falls below rate limit"; qosprofile acl_rule1 QP1; cli "configure qosprofile qp3 maxbw 100 ports all" ; } }

Ratio Expression Example


In this example, every 2 seconds the CLEAR-Flow agent will request the counter1 and counter2 statistics from the hardware. After it receives the two counter values, it will then check each counter value against its minimum valid threshold, which is 1000. If both of the counter values is greater then 1000, it then calculates the ratio of counter1 and counter2. If the ratio is greater than 5, then the agent will execute the actions in the then clause, which consists of logging a message to the syslog server. Before logging the syslog string, the agent will replace the $ruleName keyword with the string cflow_ratio_rule_example, the $ruleValue keyword with the calculated ratio value, and the $ruleThreshold keyword with a value of 5. If either of the counter values is below the minimum value of 1000, or the ratio is below the threshold of 5, the expression is false and no action is taken.
entry acl_rule1 { if { protocol udp; } then { count counter1; } } entry acl_rule2 { if {

390

ExtremeWare XOS 11.3 Concepts Guide

CLEAR-Flow Rule Examples


protocol tcp; } then { count counter2; } }

entry cflow_ratio_rule_example { if { ratio counter1 counter2 > 5 ; period 2; min-value 1000; } then { syslog "Rule $ruleName threshold ratio $ruleValue exceeds limit $ruleThreshold"; } }

ExtremeWare XOS 11.3 Concepts Guide

391

CLEAR-Flow

Delta-Ratio Expression Example


In this example, every 2 seconds, the CLEAR-Flow agent will request the tcpSynCounter and tcpCounter values from the hardware. After it receives the two counter values, it will first calculate the delta for each of the counters and then check each counters delta value for its minimum value, which is 100. If both of the counters delta values are greater then 100, it then calculates the ratio of the delta of two counters. If the ratio is greater than 10, then the agent will log a warning message and deny all SYN traffic on the interface. No period value for the syslog message is given, so the message will be logged once when the expression first becomes true. When the expression transitions from true to false, a different message will be logged and the SYN traffic on the interface will be permitted again. The deltaratio value has to fall below a threshold of 8 for the expression to be evaluated to be false.
entry acl_syn { if { protocol tcp_flags SYN; } then { count tcpSynCounter; } } entry acl_tcp { if { protocol tcp; } then { count tcpCounter; } } entry cflow_delta_ratio_rule_example { if { delta-ratio tcpSynCounter tcpCounter > 1 ; period 2; min-value 100; } then { syslog "Syn attack on port $port is detected" WARN; deny acl_syn; } else { syslog "Syn attack on port $port is no longer detected" WARN; permit acl_syn; } }

392

ExtremeWare XOS 11.3 Concepts Guide

Using Switching and Routing Protocols

19 Ethernet Automatic Protection Switching


This chapter covers the following topics:

Licensing on page 395 Overview of the EAPS Protocol on page 395 Fault Detection and Recovery on page 397 Multiple EAPS Domains on page 400 Configuring EAPS on a Switch on page 403 Configuring EAPS Shared Ports on page 411 EAPS Shared Port Configuration Rules on page 418 EAPS Shared Port Configuration Examples on page 419

Licensing
You must have a Core or an Advanced Core license to configure and use all of the Ethernet Automatic Protection Switching (EAPS) features described in this chapter. The BlackDiamond 10K switch with an MSM-1 module or an MSM1-XL module ships with a Core or Advanced Core license, respectively. The BlackDiamond 8800 family of switches (formerly known as Aspen) and the Summit X450 switch ship with an Advanced Edge license. To use the complete EAPS functionality, including running two or more EAPS rings, having a switch belonging to multiple EAPS rings, or configuring shared-ports that allow multiple EAPS domains to share a common link, you must have a Core software license. A subset of EAPS, called EAPS Edgemode, is available with an Advanced Edge license and supports a subset of EAPS. The following features are available with EAPS Edgemode:

Switches can belong to only one EAPS ring. Multiple EAPS domains using two matching ring ports.

For more information about software licensing, including how to obtain and upgrade your license, see Chapter 1, ExtremeWare XOS Overview.

Overview of the EAPS Protocol


The EAPS protocol provides fast protection switching to Layer 2 switches interconnected in an Ethernet ring topology, such as a Metropolitan Area Network (MAN) or large campuses (see Figure 17). EAPS protection switching is similar to what can be achieved with the Spanning Tree Protocol (STP), but EAPS offers the advantage of converging in less than 1 second when a link in the ring breaks.

ExtremeWare XOS 11.3 Concepts Guide

395

Ethernet Automatic Protection Switching An Ethernet ring built using EAPS can have resilience comparable to that provided by SONET rings, at a lower cost and with fewer restraints (such as ring size). The EAPS technology developed by Extreme Networks to increase the availability and robustness of Ethernet rings is described in RFC 3619: Extreme Networks Ethernet Automatic Protection Switching (EAPS) Version 1. EAPS operates by declaring an EAPS domain on a single ring. Any virtual LAN (VLAN) that warrants fault protection is configured on all ring ports in the ring, and is then assigned to an EAPS domain. On that ring domain, one switch, or node, is designated the master node (see Figure 18), while all other nodes are designated as transit nodes.

Figure 17: Gigabit Ethernet fiber EAPS MAN ring


Transit node Transit node

Gigabit Ethernet Fiber EAPS MAN ring Transit node

Transit node

Master node

EW_070

One port of the master node is designated the master nodes primary port (P) to the ring; another port is designated as the master nodes secondary port (S) to the ring. In normal operation, the master node blocks the secondary port for all non-control traffic belonging to this EAPS domain, thereby avoiding a loop in the ring, like STP. Layer 2 switching and learning mechanisms operate per existing standards on this ring.

NOTE
Like the master node, each transit node is also configured with a primary port and a secondary port on the ring, but the primary/secondary port distinction is ignored as long as the node is configured as a transit node.

396

ExtremeWare XOS 11.3 Concepts Guide

Fault Detection and Recovery

Figure 18: EAPS operation

S4 S3 S5

S2 P S1
Direction of health-check message

S6 S
Secondary port is logically blocked Master node

EW_071

If the ring is complete, the master node logically blocks all data traffic in the transmit and receive directions on the secondary port to prevent a loop. If the master node detects a break in the ring, it unblocks its secondary port and allows data traffic to be transmitted and received through it.

Fast Convergence
The Fast Convergence mode allows EAPS to converge more rapidly. In EAPS Fast Convergence mode, the link filters on EAPS ring ports are turned off. In this case, an instant notification is sent to the EAPS process if a ports state transitions from up to down or vice-versa. You configure Fast Convergence for the entire switch, not by EAPS domain.

Fault Detection and Recovery


EAPS fault detection on a ring is based on a single control VLAN per EAPS domain. This EAPS domain provides protection to one or more data-carrying VLANs called protected VLANs. The control VLAN is used only to send and receive EAPS messages; the protected VLANs carry the actual data traffic. As long as the ring is complete, the EAPS master node blocks the protected VLANs from accessing its secondary port.

NOTE
The control VLAN is not blocked. Messages sent on the control VLAN must be allowed into the switch for the master node to determine whether the ring is complete. To avoid loops in the network, the control VLAN must be NOT be configured with an IP address, and ONLY ring ports may be added to this VLAN.

ExtremeWare XOS 11.3 Concepts Guide

397

Ethernet Automatic Protection Switching A master node detects a ring fault in one of three ways:

Link down message sent by a transit node Ring port down event sent by hardware layers Polling response

The rest of this section describes the fault detection methods and the applicable restoration options.

Link Down Message Sent by a Transit Node


When any transit node detects a loss of link connectivity on any of its ring ports, it immediately sends a link down message on the control VLAN using its good link to the master node. When the master node receives the link down message (see Figure 19), it immediately declares a failed state and opens its logically blocked secondary port on all the protected VLANs. Now, traffic can flow through the masters secondary port. The master node also flushes its FDB and sends a message on the control VLAN to all of its associated transit nodes to flush their forwarding databases as well, so that all of the switches can learn the new paths to Layer 2 endstations on the reconfigured ring topology.

Figure 19: EAPS fault detection and protection switching


Break in ring

S4

S4 sends "link down" message to master node

S3
S3 sends "link down" message to master node

S5

S2 P S1 S

S6

Master node opens secondary port to allow traffic to pass Master node

EW_072

Ring Port Down Event Sent by Hardware Layer


When a ring port goes down on a master node switch, it is notified by the lower hardware layer and immediately goes into a failed state. If the ring port that goes down on the master node is the primary port, the secondary port is opened. The normal operation of flushing the master nodes FDB and sending a flush FDB message to all transit nodes is performed.

398

ExtremeWare XOS 11.3 Concepts Guide

Fault Detection and Recovery

Polling
The master node transmits a health check packet on the control VLAN at a user-configurable interval (see Figure 18). If the ring is complete, the master node receives the health-check packet on its secondary port (the control VLAN is not blocked on the secondary port). When the master node receives the health-check packet, it resets its failtimer and continues normal operation. If the master node does not receive the health check packet before the failtimer interval expires and the failtime expiry action is set to open-secondary-port, it declares a failed state and performs the same steps described above:

Unblocks its secondary port for access by the protected VLANs. Flushes its forwarding database (FDB). Sends a flush FDB message to its associated transit nodes.

Restoration Operations
The master node continues sending health check packets out its primary port even when the master node is operating in the failed state. As long as there is a break in the ring, the fail period timer of the master node continues to expire, and the master node remains in the failed state. When the broken link is restored, the master receives its health check packet back on its secondary port and once again declares the ring to be complete. Again, the master node logically:

Blocks the protected VLANs on its secondary port. Flushes its FDB. Sends a flush FDB message to its associated transit nodes.

During the time between when the transit node detects that the link is operable again and when the master node detects that the ring is complete, the secondary port on the master node is still open and data could start traversing the transit node port that just came up. To prevent the possibility of a such a temporary loop, when the transit node detects that its failed link is up, it performs these steps: 1 For the port that just came up, put all the protected VLANs traversing that port into a temporary blocked state. 2 Remember which port has been temporarily blocked. 3 Set the state to Preforwarding. When the master node receives its health check packet back on its secondary port and detects that the ring is once again complete, it sends a message to all its associated transit nodes to flush their forwarding databases. When the transit nodes receive the message to flush their forwarding databases, they perform these steps: 1 Flush their forwarding databases on the protected VLANs. 2 If the port state is set to Preforwarding, unblock all the previously blocked protected VLANs for the port.

ExtremeWare XOS 11.3 Concepts Guide

399

Ethernet Automatic Protection Switching

Multiple EAPS Domains


This section illustrates how you can work with more than one EAPS domain. The scenarios described in this section include the following:

EAPS Data VLAN Spanning Two Rings Connected by One Switch on page 400 Multiple EAPS Domains per RingSpatial Reuse on page 401 Multiple EAPS Rings Sharing a Common Link on page 402

EAPS Data VLAN Spanning Two Rings Connected by One Switch


Figure 20 shows how a data VLAN could span two rings interconnected by a common switcha figure eight topology. In this example, there is an EAPS domain with its own control VLAN running on ring 1 and another EAPS domain with its own control VLAN running on ring 2. A data VLAN that spans both rings will be added as a protected VLAN to both EAPS domains. Switch S5 has two instances of EAPS domains running on it: one for each ring. With this topology, switch S5 must have a core or an advanced core license to run two EAPS domains. All other participating switches can have an advanced edge license.

Figure 20: EAPS data VLAN spanning two rings interconnected by one switch

S4 S3 Ring 1 S2 S5 S S1
Master node

S6 S7 Ring 2 S P S9
EW_073

S 8 Master node

400

ExtremeWare XOS 11.3 Concepts Guide

Multiple EAPS Domains

Multiple EAPS Domains per RingSpatial Reuse


To take advantage of the spatial reuse technology and broaden the use of the rings bandwidth, EAPS supports multiple EAPS domains running on the ring at the same time (Figure 21).

Figure 21: Multiple EAPS domains per ring


Master EAPS 1 Transit EAPS 2

S
EAPS 1

Transit EAPS 1 Transit EAPS 2

EAPS 1 EAPS 2

Transit EAPS 1 Transit EAPS 2

EAPS 2

Master EAPS 2 Transit EAPS 1


EX_100

So, a single ring might have two EAPS domains running on it. Each EAPS domain would have a different EAPS master node. Each EAPS domain will protect its own set of protected VLANS. In a spatial reuse configuration, do not add the same protected VLAN to both EAPS domains. You can also use spatial reuse with EAPS shared ports as shown in Figure 22. The advantage of this topology is that you can configure common links between multiple rings and configure multiple EAPS domains on each ring. To utilize this topology and configure EAPS shared ports, you must have a core or an advanced core license.

ExtremeWare XOS 11.3 Concepts Guide

401

Ethernet Automatic Protection Switching

Figure 22: EAPS shared ports configuration with spatial reuse

EX_105

For information about configuring common links and EAPS shared ports, see Configuring EAPS Shared Ports on page 411.

Multiple EAPS Rings Sharing a Common Link


When you configure EAPS on multiple rings with a common link, you may experience a loop situation across both rings. To solve this problem you can configure EAPS shared ports. NOTE
You must have a core or an advanced core license to use the EAPS shared port feature.

In the example shown in Figure 20, switch S5 could be a single point of failure. If switch S5 were to go down, users on Ring 1 would not be able to communicate with users on Ring 2. To make the network more resilient, you can add another switch, S10. The link connecting S5 to S10 is knows as the common link, as shown in Figure 23.

402

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS on a Switch

Figure 23: Multiple EAPS domains sharing a common link with EAPS shared ports

S4 S3 EAPS1
link ID=1

S5
Controller

S6 S7 EAPS2

Common link

S2

P S1
Master node

Partner

S S9
Master node

S8

S 10

EW_095

The switches on either end of the common link must be configured as controller and a partner. For information about configuring common links, see Configuring EAPS Shared Ports on page 411.

NOTE
If the shared port is not configured and the common link goes down a superloop between the multiple EAPS domains will occur.

NOTE
In order to take advantage of the Spatial Reuse technology in a shared-port environment in this software release, you can use the existing solution of configuring EAPS plus STP.

Configuring EAPS on a Switch


To configure and enable an EAPS domain, complete the following steps: 1 Create EAPS domain and assign the name. 2 Configure the control VLAN. 3 Configure the protected VLAN(s). 4 Add the control VLAN to EAPS domain. 5 Add the protected VLAN(s) to EAPS domain. 6 Configure EAPS mode, master or transit. 7 Configure EAPS port, secondary and primary. 8 If desired, configure timeout and action for failtimer expiration*. 9 If desired, configure the hello time for the health-check packets*. 10 Enable EAPS for the entire switch.

ExtremeWare XOS 11.3 Concepts Guide

403

Ethernet Automatic Protection Switching 11 If desired, enable Fast Convergence*. 12 Enable EAPS for the specified domain. Although you can enable EAPS prior to configuring these steps, the EAPS domain(s) will not run until you configure these parameters. (The steps with * can be configured at any time, even after the EAPS domains are running.)

Creating and Deleting an EAPS Domain


Each EAPS domain is identified by a unique domain name. To create an EAPS domain, use the following command:
create eaps <name>

The name parameter is a character string of up to 32 characters that identifies the EAPS domain to be created.

NOTE
If you use the same name across categories (for example, STPD and EAPS names), Extreme Networks recommends that you specify the identifying keyword as well as the actual name. If you do not use the keyword, the system may return an error message.

The following command example creates an EAPS domain named eaps_1:


create eaps eaps_1

To delete an EAPS domain, use the following command:


delete eaps <name>

The following command example deletes the EAPS domain eaps_1:


delete eaps eaps_1

Defining the EAPS Mode of the Switch


To configure the EAPS node type of the switch, use the following command:
configure eaps <name> mode [master | transit]

One node (or switch) on the ring must be configured as the master node for the specified domain; all other nodes (or switches) on the ring are configured as transit nodes for the same domain. The following command example identifies this switch as the master node for the EAPS domain named eaps_1.
configure eaps eaps_1 mode master

The following command example identifies this switch as a transit node for the EAPS domain named eaps_1.
configure eaps eaps_1 mode transit

404

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS on a Switch

Configuring EAPS Polling Timers


To set the values of the polling timers the master node uses for the EAPS health check packet that is circulated around the ring for an EAPS domain, use the following commands:
configure eaps <name> hellotime <seconds> configure eaps <name> failtime <seconds>

NOTE
These commands apply only to the master node. If you configure the polling timers for a transit node, they will be ignored. If you later reconfigure that transit node as the master node, the polling timer values will be used as the current values.

Use the hellotime keyword and its associated seconds parameter to specify the amount of time the master node waits between transmissions of health check packets on the control VLAN. The value for seconds must be greater than 0 when you are configuring a master node. The default value is 1 second.

NOTE
Increasing the hellotime value keeps the processor from sending and processing too many health check packets.

Use the failtime keyword and seconds parameters to specify the amount of time the master node waits before the failtimer expires. The seconds parameter must be greater than the configured value for hellotime. The default value is 3 seconds. To configure the action taken if there is a break in the ring, use the following command:
configure eaps <name> failtime expiry-action [open-secondary-port | send-alert]

You can configure the action taken when the failtimer expires by using the configure eaps failtime expiry-action command. Use the send-alert parameter to send an alert when the failtimer expires. Instead of going into a failed state, the master node remains in a Complete or Init state, maintains the secondary port blocking, and writes a critical error message to syslog warning the user that there is a fault in the ring. An SNMP trap is also sent. Use the open-secondary-port parameter to open the secondary port when the failtimer expires.

NOTE
Increasing the failtime value provides more protection by waiting longer to receive a health check packet when the network is congested.

The following command examples configure the hellotime value for the EAPS domain eaps_1 to 2 seconds, the failtimer value to 15 seconds, and the failtimer expiry-action to open the secondary port if the failtimer expires:
configure eaps eaps_1 hellotime 2 configure eaps eaps_1 failtime 15 configure eaps eaps_1 failtimer expiry-action open-secondary-port

ExtremeWare XOS 11.3 Concepts Guide

405

Ethernet Automatic Protection Switching

Configuring the Primary and Secondary Ports


Each node on the ring connects to the ring through two ring ports. As part of the protection switching scheme, one port must be configured as the primary port, and the other must be configured as the secondary port. If the ring is complete, the master node prevents a loop by logically blocking all data traffic in the transmit and receive directions on its secondary port. If the master node subsequently detects a break in the ring, it unblocks its secondary port and allows data traffic to be transmitted and received through it. To configure a node port as primary or secondary, use the following command:
configure eaps <name> [primary | secondary] port <ports>

The following command example adds port 1 of the module installed in slot 8 of the switch to the EAPS domain eaps_1 as the primary port.
configure eaps eaps_1 primary port 8:1

Configuring the EAPS Control VLAN


You must configure one control VLAN for each EAPS domain. The control VLAN is used only to send and receive EAPS messages. NOTE
A control VLAN cannot belong to more than one EAPS domain. If the domain is active, you cannot delete the domain or modify the configuration of the control VLAN.

To configure the EAPS control VLAN for the domain, use the following command:
configure eaps <name> add control vlan <vlan_name>

NOTE
The control VLAN must NOT be configured with an IP address. In addition, only ring ports may be added to this control VLAN. No other ports can be members of this VLAN. Failure to observe these restrictions can result in a loop in the network.

NOTE
The ring ports of the control VLAN must be tagged.

The control VLAN with a QoS profile of QP8 (with the QoS profile HighHi priority setting) ensures that the EAPS control VLAN traffic is serviced before any other traffic and that control VLAN messages reach their intended destinations. Because the QoS profile HighHi priority setting by itself should ensure that the control VLAN traffic gets through a congested port first, you should not need to set the QoS profile minimum bandwidth (minbw) or maximum bandwidth (maxbw) settings. However, if you plan to use QoS (profile priority and bandwidth settings) for other traffic, you might need to set a minbw value on QP8 for control VLAN traffic. Whether you need to do this depends entirely on your configuration.

406

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS on a Switch The following command example adds the control VLAN keys to the EAPS domain eaps_1.
configure eaps eaps_1 add control vlan keys

Configuring the EAPS Protected VLANs


You must configure one or more protected VLANs for each EAPS domain. The protected VLANs are the data-carrying VLANs. NOTE
When you configure the VLAN that will act as a protected VLAN, the ring ports of the protected VLAN must be tagged (except in the case of the default VLAN).

To configure an EAPS protected VLAN, use the following command:


configure eaps <name> add protect vlan <vlan_name>

NOTE
As long as the ring is complete, the master node blocks the protected VLANs on its secondary port.

The following command example adds the protected VLAN orchid to the EAPS domain eaps_1.
configure eaps eaps_1 add protect vlan orchid

Enabling and Disabling Fast Convergence


You enable Fast Convergence on the entire switch; this feature ensures convergence in less than 50 milliseconds. To enable or disable Fast Convergence on the switch, use the following command:
configure eaps fast-convergence [off | on]

Enabling and Disabling an EAPS Domain


To enable a specific EAPS domain, use the following command:
enable eaps {<name>}

To disable a specific EAPS domain, use the following command:


disable eaps {<name>}

Enabling and Disabling EAPS on the Switch


To enable the EAPS function for the entire switch, use the following command:
enable eaps

ExtremeWare XOS 11.3 Concepts Guide

407

Ethernet Automatic Protection Switching To disable the EAPS function for the entire switch, use the following command:
disable eaps

Unconfiguring an EAPS Ring Port


Unconfiguring an EAPS port sets its internal configuration state to INVALID, which causes the port to appear in the Idle state with a port status of Unknown when you use the show eaps {<eapsDomain>} {detail} command to display the status information about the port. To unconfigure an EAPS primary or secondary ring port for an EAPS domain, use the following command:
unconfigure eaps <name> [primary | secondary] port

The following command example unconfigures this nodes EAPS primary ring port on the domain eaps_1:
unconfigure eaps eaps_1 primary port

Displaying EAPS Status Information


To display EAPS status information, use the following command:
show eaps

This example displays summary EAPS information:


EAPS Enabled: Yes EAPS Fast-Convergence: Off Number of EAPS instances: 2 # EAPS domain configuration : -------------------------------------------------------------------------------Domain State Mo En Pri Sec Control-Vlan VID Count -------------------------------------------------------------------------------d1 Complete M Y 3:8 3:16 c1 (1000) 100 d2 Links-Up T Y 3:8 3:16 c2 (1001) 100 --------------------------------------------------------------------------------

The following display shows sample output for the command show eaps <eapsDomain>:
Name: d1 State: Complete Running: Yes Enabled: Yes Mode: Master Primary port: 3:8 Port status: Up Tag status: Tagged Secondary port: 3:16 Port status: Blocked Tag status: Tagged Hello timer interval: 1 sec Fail timer interval: 3 sec Fail Timer expiry action: Send alert Last update: From Master Id 00:01:30:f9:9c:b0, at Wed Jun 9 09:09:35 2004 EAPS Domain has following Controller Vlan: Vlan Name VID c1 1000 EAPS Domain has following Protected Vlan(s): Vlan Name VID

408

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS on a Switch


p_1 p_2 p_3 p_4 p_5 p_6 p_7 p_8 p_9 p_10 p_11 p_12 p_13 p_14 p_15 p_16 p_17 p_18 p_19 p_20 p_21 p_22 p_23 p_24 p_25 p_26 p_27 p_28 p_29 p_30 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

NOTE
You may see a slightly different display, depending on whether you display the master node or the transit node.

The display from the show eaps detail command shows all the information shown in the show eaps <eapsDomain> command, but displays information for all configured EAPS domains. Table 57 explains the fields on the EAPS display.

Table 57: show eaps display fields


Field EAPS Enabled Description Current state of EAPS on this switch: YesEAPS is enabled on the switch. NoEAPS is not enabled. EAPS Fast Convergence Number of EAPS instances Name Displays only when Fast Convergence is on. Number of EAPS domains created. The maximum number of EAPS domains per switch is 128. The configured name for this EAPS domain.

ExtremeWare XOS 11.3 Concepts Guide

409

Ethernet Automatic Protection Switching

Table 57: show eaps display fields (Continued)


Field State Description On a transit node, the command displays one of the following states: IdleThe EAPS domain has been enabled, but the configuration is not complete. Links-UpThis EAPS domain is running, and both its ports are up and in the forwarding state. Links-DownThis EAPS domain is running, but one or both of its ports are down. PreforwardingThis EAPS domain is running, and both of its ports are up, but one of them is in a temporary blocked state. On a master node, the command displays one of the following states: IdleThe EAPS domain has been enabled, but the configuration is not complete. InitThe EAPS domain has started but has not yet determined the status of the ring. The secondary port is in a blocked state. CompleteThe ring is in the complete state for this EAPS domain. FailedThere is a break in the ring for this EAPS domain. Pre-InitThe EAPS domain has started operation for Init state and has sent a request to lower hardware layers to block the secondary port. It is in transient state waiting for acknowledgement from hardware layer indicating the operation is completed. Pre-CompleteThe EAPS domain has started operation for Complete state and has sent a request to lower hardware layers to block the secondary port. It is in transient state waiting for acknowledgement from the hardware layer indicating the operation is completed. [Failtimer Expired]When the failtimer expires and its action is set to send-alert, this flag is set. This flag indicates there is a misconfiguration or hardware problem in the EAPS ring. The EAPS master node will continue to remain in COMPLETE or INIT state with its secondary port blocking. [Running: ] Enabled YesThis EAPS domain is running. NoThis EAPS domain is not running. Indicates whether EAPS is enabled on this domain: YEAPS is enabled on this domain. NEAPS is not enabled. Mode Primary/Secondary port The configured EAPS mode for this switch: transit (T) or master (M). The port numbers assigned as the EAPS primary and secondary ports. On the master node, the port distinction indicates which port is blocked to avoid a loop. Indicates port status as one of the following states: UnknownThis EAPS domain is not running, so the port status has not yet been determined. UpThe port is up and is forwarding data. DownThe port is down. BlockedThe port is up, but data is blocked from being forwarded.

Port status

410

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS Shared Ports

Table 57: show eaps display fields (Continued)


Field Tag status Description Tagged status of the control VLAN: TaggedThe control VLAN has this port assigned to it, and the port is tagged in the VLAN. UntaggedThe control VLAN has this port assigned to it, but the port is untagged in the control VLAN. UndeterminedEither a VLAN has not been added as the control VLAN to this EAPS domain or this port has not been added to the control VLAN. Hello Timer interval Fail Timer interval Failtimer expiry action1 The configured value of the timer in seconds, specifying the time that the master node waits between transmissions of health check packets. The configured value of the timer in seconds, specifying the time that the master node waits before the failtimer expires. Displays the action taken when the failtimer expires: Send-alertSends a critical message to the syslog when the failtimer expires. Open-secondary-portOpens the secondary port when the failtimer expires. Preforwarding Timer interval2 Last update EAPS Domain has Controller Vlans EAPS Domain has Protected Vlans Number of Protected Vlans The configured value of the timer. This value is set internally by the EAPS software. Indicates the last time a hello packet is received from the master node. Lists the assigned name and ID of the control VLAN. Lists the assigned names and VLAN IDs of all the protected VLANs configured on this EAPS domain. The count of protected VLANs configured on this EAPS domain.

1. This field applies only to master nodes; it does not display for a transit mode. 2. These fields apply only to transit nodes; they are not displayed for a master node.

Configuring EAPS Shared Ports


NOTE
You must have a core or an advanced core license to use the EAPS shared port feature.

When multiple EAPS rings share a physical link, this link is referred to as the common link. Each node on either end of this common link should be configured with an EAPS shared port instance. You must configure one node of the common link as the controller and the node on the other end as the partner. Each common link in the EAPS network must have a unique link ID. The controller and partner shared ports belonging to the same common link must have matching link IDs. These controller and partner nodes with matching link IDs must be directly connected to each other. No other instance in the network should have that link ID. During normal operation, both the controller and the partner send segment health check messages on their EAPS domain every second. In the situation described above, if there is no EAPS shared ports configuration, and the common link fails, this might result in a superloop.

ExtremeWare XOS 11.3 Concepts Guide

411

Ethernet Automatic Protection Switching

Steady State
In steady state when the common link is up, both the controller and partner are said to be in the ready state. After EAPS has converged and the EAPS master node has blocked its own secondary ports, the controller puts all its ports into forwarding, and goes back to ready state.

Figure 24: Multiple EAPS domain steady state


S3
P2 P3

S9
P4

S1
Controller EAPS1 P1 link ID=10 P5

S6
EAPS2

EAPS3

S4

Common link

S7

S10

S2
Partner

P8 P7

S8
Master

S5
Master

P6

S11
Master
EX_104

Figure 24 shows a multiple EAPS domain steady state, where:


EAPS1 is the EAPS domain for ring S1, S3, S4, S5, and S2 EAPS2 is the EAPS domain for ring S1, S6, S7, S8, and S2 EAPS3 is the EAPS domain for ring S1, S9, S10, S11, and S2 P1, P2, P3, and P4 are the ports on switch S1 P5, P6, P7, and P8 are the ports on switch S2 S5, S8, and S11 are the master nodes of their respective EAPS domains S3, S4, S6, S7, S9, and S10 are the transit nodes of their respective EAPS domains S1 and S2 are running EAPSv2 S1 is the controller S2 is the partner P1 is the EAPS shared port on switch S1 P5 is the EAPS shared port on switch S2 Link ID 10 is the unique identifier for the common link

Common Link Failures


If a single common link fails, the configured controller (S1) and partner (S2) take steps to prevent a superloop. Assuming there is a single data VLAN configured on all three EAPS domains, the controller (S1) keeps one port open (called Active-Open). The remaining segment ports are blocked to prevent a superloop. In Figure 25, P2 is the Active-Open port on S1. Ports P3 and P4 are blocked. The master nodes (S5, S8, and S11) open their secondary ports.

412

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS Shared Ports

Figure 25: EAPS domain common link failure


S3
P2 Active-Open P3
EAPS3

S9

S1
Controller P4

S6 S7 S10

S4
EAPS1

P1

x
S2
Partner

EAPS2

S8
Master

S5
Master

S11
Master
EW_102b

When the common link is restored, the controller goes into Preforwarding state. After the controller receives notification from the master nodes that they have converged and blocked their secondary ports, the controller opens all ports. If you have an EAPS configuration with multiple common links and a second common link fails, the controllers continue to take steps to prevent a superloop. In addition to having one controller with an Active-Open port, the controller with the smallest link ID becomes the root blocker. There can be only one root blocker in the network.

Port Considerations
In an EAPS shared port configuration, the segment ports are sorted in ascending order based on their port number, not the order you add an EAPS domain to EAPS shared ports. This is particularly useful when planning your EAPS configuration. The benefit of sorting ports in ascending order is evident if a common link fails. The port with the lowest port number among the segment ports in the UP state becomes the Active Open port. When configuring your EAPS domain, keep the port numbers in mind. For high bandwidth links, utilize lower port numbers, and for low bandwidth links, utilize higher port numbers. This way, if a common link fails, the high bandwidth link is still available.

NOTE
The order you add EAPS domains to EAPS shared ports is relevant if the EAPS domains have matching ring ports and participate in spatial reuse. In this case, the show eaps shared-port {<port>} {detail} command displays the newly added EAPS domain after all other existing EAPS domains with the same matching ring port.

To display EAPS shared port status information, use the following command:
show eaps shared-port {<port>} {detail}

ExtremeWare XOS 11.3 Concepts Guide

413

Ethernet Automatic Protection Switching

Flushing the FDBs


When a controller goes into or out of the blocking state, the controller sends a flush fdb message to flush all of the FDBs of the switches in its segments. Each switch in the path of the flush fdb message flushes its FDB. In a network with multiple EAPS ports in the blocking state, the flush fdb message gets propagated across the boundaries of the EAPS domains.

Creating and Deleting a Shared Port


To configure a common link, you must create a shared port on each switch belonging to the common link. To create a shared port, use the following command:
create eaps shared-port <ports>

where ports is the common link port.

NOTE
A switch can have a maximum of two shared ports.

To delete a shared port on the switch, use the following command:


delete eaps shared-port <ports>

Defining the Mode of the Shared Port


The shared port on one end of the common link must be configured to be the controller. This is the end responsible for blocking ports when the common link fails thereby preventing the superloop. The shared port on the other end of the common link must be configured to be the partner. This end does not participate in any form of blocking. It is responsible for only sending and receiving healthcheck messages. To configure the mode of the shared port, use the following command:
configure eaps shared-port <ports> mode <controller | partner>

Configuring the Link ID of the Shared Port


Each common link in the EAPS network must have a unique link ID. The controller and partner shared ports belonging to the same common link must have matching link IDs. No other instance in the network should have that link ID. To configure the link ID of the shared port, use the following command:
configure eaps shared-port <ports> link-id <id>

414

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS Shared Ports

Configuring the Shared Port Segment Timer


To configure the segment timer, use the following command:
configure eaps shared-port <ports> segment-timeout expiry-action [segment-down | sendalert]

Where the following is true:

segment-downIf the controller or partner switchs segment timer expires, that segment is set to down, and a query is not sent through the ring. send-alertIf the controller or partner switchs segment timer expires, that switch keeps the

segment up, with the failed flag set, and sends a warning message to the log. All segments, including the controller and partner shared ports belonging to the same common link, must use the same segment timer expiry action. By default, the segment timer expiry action is send-alert and the timer is set to 3 seconds.

Unconfiguring an EAPS Shared Port


To unconfigure a link ID on a shared port, use the following command:
unconfigure eaps shared-port <ports> link-id

To unconfigure the mode on a shared port, use the following command:


unconfigure eaps shared-port <ports> mode

To delete a shared port, use the following command:


delete eaps shared-port <ports>

Displaying EAPS Shared-Port Status Information


To display EAPS shared port status information, use the following command:
show eaps shared-port {<port>} {detail}

If you enter the show eaps shared-port command without an argument or keyword, the command displays a summary of status information for all configured EAPS shared ports. If you specify an EAPS shared-port, the command displays information about that specific port. Otherwise, the command displays information about all of the shared-ports configured on the switch. You can use the detail keyword to display more detailed status information about the segments and VLANs associated with each shared port.

ExtremeWare XOS 11.3 Concepts Guide

415

Ethernet Automatic Protection Switching The following examples of the show eaps shared-port command displays shared port information when the EAPS domain is in a ready state (for example, when the common link is up).
EAPS shared-port count: 1 -------------------------------------------------------------------------------Link Domain Vlan RB RB Shared-port Mode Id Up State count count Nbr State Id -------------------------------------------------------------------------------10:1 Controller 1 Y Ready 2 1 Yes None None Segment Timer expiry action: Send alert --------------------------------------------------------------------------------

Table 58 describes the significant fields and values in the display output of the show eaps sharedport {<port>} {detail} commands.

Table 58: show eaps shared-port display fields


Field Shared Port Mode Link ID Up Description Displays the port number of the shared port. Indicates whether the switch on either end of the common link is a controller or partner. The mode is configured by the user. The link ID is the unique common link identifier configured by the user. Displays one of the following states: YesIndicates that the link ID and the mode are configured. NoIndicates that the link ID or the mode is not configured. State Displays one of the following states: IdleShared-port instance is not running. ReadyThe EAPS shared-port instance is running, the neighbor can be reached, and the common link is up. BlockingThe EAPS shared-port instance is running, the neighbor cannot be reached, or the common link is down. PreforwardingThe EAPS shared-port instance is in a blocking state, and the common link came up. To prevent a superloop, a temporary blocking state is created before going into Ready state. Domain Count VLAN Count Indicates the number of EAPS domains sharing the common link. Indicates the total number of VLANs that are protected under the EAPS domains sharing this common link.

416

ExtremeWare XOS 11.3 Concepts Guide

Configuring EAPS Shared Ports

Table 58: show eaps shared-port display fields (Continued)


Field Nbr Description Displays one of the following states: YesIndicates that the EAPS instance on the other end of the common link is configured with matching link ID and opposite modes. For example, if one end of the common link is configured as a controller, the other end must be configured as a partner. ErrIndicates that the EAPS instance on the other end of the common link is configured with a matching link ID, but the modes are configured the same (for example, both modes are configured as controller, or both modes are configured as partner. NoIndicates one or more of the following: - The switch on the other end of the common link is not running. - The shared port has not been created. - The link IDs on each side of the common link do not match. - The common link, and any other segment between the controller and partner are not fully connected. RB State Displays one of the following states: NoneThis EAPS shared-port is not the root blocker. ActiveThis EAPS shared-port is the root blocker and is currently active. InactiveThis EAPS shared-port is the root blocker but is currently inactive. RB ID Active Open (available with the detail keyword) Segment Timer expiry action The ID of the root blocker. If the value is none, there are not two or more common-link failures. NoneIndicates that there is no Active-Open port on the VLAN. Port #Indicates the port that is Active-Open and is in a forwarding state. Segment downSpecifies that if the controller or partner switch detect a down segment, that segment stays down and a query is not sent through the ring. The switch marks the segment status as "Down." Send alertSpecifies that if the controller or partner switch detect a down segment, that switch keeps the segment up and sends a warning message to the log (default). The switch sends a trap alert and sets the failed flag [F]. Segment Port (available with the detail keyword or by specifying a shared port) Status (available with the detail keyword or by specifying a shared port) The segment port is the other ring port of an EAPS domain that is not the shared-port. UpThere is connectivity to the neighboring EAPS shared-port via this port. DownThere is a break in the path to the neighboring EAPS shared-port via this port. Blocking-UpThe path is Up, but due to the "root blocker" being in the Active state, this port is blocked to prevent a loop. Blocking-DownThe path is Down, but due to the "root blocker" being in the Active state, this port is blocked to prevent a loop. [F]The segment timer has expired but has not received an explicit link-down notification. The port remains in the Up state, with the timer expired flag set to True.

ExtremeWare XOS 11.3 Concepts Guide

417

Ethernet Automatic Protection Switching

Table 58: show eaps shared-port display fields (Continued)


Field EAPS Domain (available with the detail keyword or by specifying a shared port) Vlan-port count (available with the detail keyword or by specifying a shared port) Adjacent Blocking Id (available with the detail keyword or by specifying a shared port) Segment RB Id (available with the detail keyword or by specifying a shared port) Vlan (available with the detail keyword or by specifying a shared port) Virtual-port Status (available with the detail keyword or by specifying a shared port) Description The EAPS domain having the segment port as one of its ring ports.

The total number of VLANs being protected under this segment port.

NoneThe neighbor on this port is not reporting a Controller in the Blocking state. <Link-Id>The neighbor on this port is a controller in the Blocking state with a link ID of <Link-Id>. NoneThe neighbor on this port is not aware of a "root blocker" in the network. <RB-Id>The neighbor on this port has determined that there is a "root blocker" in the network with a link ID of <RB-Id>. Displays a list of VLANs protected by the segment port. This information appears for the Controller, when it is in either the Blocking or Preforwarding state. Active-OpenThis VLAN or port is in the Forwarding state and has connectivity to the neighboring EAPS shared port via this port. OpenThis VLAN or port is in the Forwarding state but does not have connectivity to the neighboring EAPS shared port via this port. BlockedThis VLAN or port is in the Blocking state to prevent a loop in the network. DownThis ports link is down. ActiveAt this moment, this VLAN or port is not being handled by EAPS shared port. Rather, this VLAN or port is being handled by the regular EAPS protocol.

EAPS Shared Port Configuration Rules


The following rules apply to EAPS shared port configurations:

The controller and partner shared ports on either side of a common link must have the same link ID. Each common link in the network must have a unique link ID. The modes on either side of a common link must be different from each other; one must be a controller and one must be a partner. There can be only up to two shared ports per switch. There cannot be more than one controller on a switch. Valid combinations on any one switch are:

1 controller 1 partner

418

ExtremeWare XOS 11.3 Concepts Guide

EAPS Shared Port Configuration Examples


1 controller and 1 partner 2 partners

A shared port cannot be configured on an EAPS masters secondary port.

EAPS Shared Port Configuration Examples


This section provides examples of EAPS shared port configurations.

Basic Configuration
This example, shown in Figure 26, is the most basic configuration; two EAPS domains with a single common link between them.

Figure 26: EAPS shared port basic configuration

S4 S3 EAPS1
link ID=1

S5
Controller

S6 S7 EAPS2

Common link

S2

P S1
Master node

Partner

S S9
Master node

S8

S 10

EW_095

Basic Core Configuration


This configuration, shown in Figure 27, shows a core with access rings. In this topology, there are two EAPS common links.

ExtremeWare XOS 11.3 Concepts Guide

419

Ethernet Automatic Protection Switching

Figure 27: EAPS shared port basic core configuration


S Master node

S4
P1:2 P1:3

S7 S5 S9 EAPS2
Controller EAPS3
S

S 12

S3 EAPS1

Controller
P1:1

Common link

link ID=1

Common link link ID=2

S 11
P Master node

S2
P

S6
Partner

S 10
Partner
S

S1
Master node

S8
Master node

EAPS4

S 13
EW_096

Right Angle Configuration


In this topology, there are still two EAPS common links, but the common links are adjacent to each other. To configure a right angle configuration, there must be two common links configured on one of the switches. Figure 28 shows a Right Angle configuration.

Figure 28: EAPS shared port right angle configuration


Master node S

S5
P

EAPS1
link ID=2

S6 S7 S 10 EAPS4
S Master node

S 4 Controller

Common link

Partner Controller Common link


link ID=1

EAPS2 S3
P

EAPS3 S2
Master node

S9
P S

Partner
S

S1

S8

S 11
EW_097

Master node

Combined Basic Core and Right Angle Configuration


Figure 29 shows a combination Basic Core and Right Angle configuration.

420

ExtremeWare XOS 11.3 Concepts Guide

EAPS Shared Port Configuration Examples

Figure 29: Basic core and right angle configuration


Master node S

S7 S4 S3 EAPS1
Master node P

S8 EAPS5
link ID=3

S5
Partner Controller

S9
Controller Partner

EAPS4 EAPS3

S 14

Common link

Common link

link ID=1

Common link ID=2 link

Master node

S2
Partner
S

S 13
P S

EAPS2
P

Controller

S1

S6

S 10
S

S 15
P Master node
EW_098

S 12
Master node

S 11

Large Core and Access Rings Configuration


Figure 30 shows a single large core ring with multiple access rings hanging off of it. This is an extension of a basic core configuration.

Figure 30: Large core and access ring configuration


Master node P

S4 EAPS3

S S

S3 S2
Partner
S

S5
Partner Master

Controller
link ID=40

S6
Controller

EAPS4
link ID=30

EAPS5 EAPS1
link ID=50

S Master node

Master node

S1
P

S7
Controller Partner Controller
link ID=20 P

S 12

Partner

S8

S 11
S

EAPS2
P

S9
Master node

S 10

EW_099

ExtremeWare XOS 11.3 Concepts Guide

421

Ethernet Automatic Protection Switching

Advanced Configuration
Figure 31 shows an extension of the Basic Core and Right Angle configuration.

Figure 31: Advanced configuration


S3
Master node S

S4
Partner Master

S5
Controller

Controller
link ID=1

S2 EAPS5 S1

Common link

link ID=2

EAPS2

link ID=4

EAPS3

Common link

Common link Common link


link ID=3

S6

EAPS1
Partner Master Controller Partner

Partner Controller

S 14
S

S 13

S 12

EAPS6 S9
S

S7 S8

EAPS4 S 11
S

S 10
EW_101

422

ExtremeWare XOS 11.3 Concepts Guide

20 Spanning Tree Protocol


This chapter covers the following topics:

Overview of the Spanning Tree Protocol on page 423 Spanning Tree Domains on page 423 STP Configurations on page 430 Per VLAN Spanning Tree on page 436 Rapid Spanning Tree Protocol on page 436 STP Rules and Restrictions on page 447 Configuring STP on the Switch on page 447 Displaying STP Settings on page 452

Using the Spanning Tree Protocol (STP) functionality of the switch makes your network more fault tolerant. The following sections explain more about STP and the STP features supported by ExtremeWare XOS.

NOTE
STP is a part of the 802.1D bridge specification defined by the IEEE Computer Society. To explain STP in terms used by the IEEE 802.1D specification, the switch will be referred to as a bridge.

Overview of the Spanning Tree Protocol


STP is a bridge-based mechanism for providing fault tolerance on networks. STP allows you to implement parallel paths for network traffic and to ensure that redundant paths are:

Disabled when the main paths are operational. Enabled if the main path fails. NOTE

STP and Extreme Standby Router Protocol (ESRP) cannot be configured on the same Virtual LAN (VLAN) simultaneously.

Spanning Tree Domains


The switch can be partitioned into multiple virtual bridges. Each virtual bridge can run an independent Spanning Tree instance. Each Spanning Tree instance is called a Spanning Tree Domain (STPD). Each STPD has its own root bridge and active path. After an STPD is created, one or more VLANs can be assigned to it. A physical port can belong to multiple STPDs. In addition, a VLAN can span multiple STPDs.

ExtremeWare XOS 11.3 Concepts Guide

423

Spanning Tree Protocol The key points to remember when configuring VLANs and STP are:

Each VLAN forms an independent broadcast domain. STP blocks paths to create a loop-free environment. Within any given STPD, all VLANs belonging to it use the same spanning tree.

To create an STPD, use the following command:


create stpd <stpd_name>

To delete an STPD, use the following command:


delete stpd <stpd_name>

For more detailed information about configuring STP and STP parameters, see Configuring STP on the Switch on page 447.

Member VLANs
When you add a VLAN to an STPD, that VLAN becomes a member of the STPD. The two types of member VLANs in an STPD are:

Carrier Protected

Carrier VLAN
A carrier VLAN defines the scope of the STPD, which includes the physical and logical ports that belong to the STPD and the 802.1Q tag used to transport EMISTP or PVST+ encapsulated BPDUs (see Encapsulation Modes on page 425 for more information about encapsulating STP BPDUs). Only one carrier VLAN can exist in a given STPD, although some of its ports can be outside the control of any STPD at the same time. The StpdID must be identical to the VLANid of the carrier VLAN in that STPD. See the section Specifying the Carrier VLAN on page 424, for an example.

Protected VLAN
Protected VLANs are all other VLANs that are members of the STPD. These VLANs piggyback on the carrier VLAN. Protected VLANs do not transmit or receive STP BPDUs, but they are affected by STP state changes and inherit the state of the carrier VLAN. Protected VLANs can participate in multiple STPDs, but any particular port in the VLAN can belong to only one STPD. Also known as non-carrier VLANs.

Specifying the Carrier VLAN


The following example:

Creates and enables an STPD named s8. Creates a carrier VLAN named v5.

424

ExtremeWare XOS 11.3 Concepts Guide

Spanning Tree Domains


Assigns VLAN v5 to STPD s8. Creates the same tag ID for the VLAN and the STPD (the carrier VLANs VLANid must be identical to the STPDs StpdID).
v5 tag 100 v5 add ports 1:1-1:20 tagged s8 add vlan v5 ports all emistp s8 tag 100

create vlan v5 configure vlan configure vlan create stpd s8 configure stpd configure stpd enable stpd s8

Notice how the tag number for the VLAN v5 and the STPD s8 is identical (the tag is 100). By using identical tags, you have selected the carrier VLAN. The carrier VLANs VLANid is identical to the STPDs StpdID.

STPD Modes
An STPD has two modes of operation:

802.1D mode Use this mode for backward compatibility with previous STP versions and for compatibility with third-party switches using IEEE standard 802.1D. When configured in this mode, all rapid configuration mechanisms are disabled.

802.1w mode Use this mode for compatibility with Rapid Spanning Tree (RSTP). When configured in this mode, all rapid configuration mechanisms are enabled. The benefit of this mode is available on point-topoint links only and when the peer is likewise configured in 802.1w mode. If you do not select point-to-point links and the peer is not configured for 802.1w mode, the STPD fails back to 802.1D mode. You enable or disable RSTP on a per STPD basis only. You do not enable RSTP on a per port basis. For more information about RSTP and RSTP features, see Rapid Spanning Tree Protocol on page 436.

By default, the:

STPD operates in 802.1D mode. Default device configuration contains a single STPD called s0. Default VLAN is a member of STPD s0 with autobind enabled.

To configure the mode of operation of an STPD, use the following command:


configure stpd <stpd_name> mode [dot1d | dot1w]

All STP parameters default to the IEEE 802.1D values, as appropriate.

Encapsulation Modes
You can configure ports within an STPD to accept specific BPDU encapsulations. This STP port encapsulation is separate from the STP mode of operation. For example, you can configure a port to accept the PVST+ BPDU encapsulation while running in 802.1D mode.

ExtremeWare XOS 11.3 Concepts Guide

425

Spanning Tree Protocol An STP port has three possible encapsulation modes:

802.1D mode Use this mode for backwards compatibility with previous STP versions and for compatibility with third-party switches using IEEE standard 802.1D. BPDUs are sent untagged in 802.1D mode. Because of this, any given physical interface can have only one STPD running in 802.1D mode.

Extreme Multiple Instance Spanning Tree Protocol (EMISTP) mode EMISTP mode is proprietary to Extreme Networks and is an extension of STP that allows a physical port to belong to multiple STPDs by assigning the port to multiple VLANs. EMISTP adds significant flexibility to STP network design. BPDUs are sent with an 802.1Q tag having an STPD instance Identifier (StpdID) in the VLANid field.

Per VLAN Spanning Tree (PVST+) mode This mode implements PVST+ in compatibility with third-party switches running this version of STP. The STPDs running in this mode have a one-to-one relationship with VLANs and send and process packets in PVST+ format.

These encapsulation modes are for STP ports, not for physical ports. When a physical port belongs to multiple STPDs, it is associated with multiple STP ports. It is possible for the physical port to run in different modes for different domains to which it belongs. To configure the BPDU encapsulation mode for one or more STP ports, use the following command:
configure stpd <stpd_name> ports mode [dot1d | emistp | pvst-plus] <port_list>

To configure the default BPDU encapsulation mode on a per STPD basis, use the following command:
configure stpd <stpd_name> default-encapsulation [dot1d | emistp | pvst-plus]

Instead of accepting the default encapsulation modes of dot1d for the default STPD s0 and emistp for all other STPDs, this command allows you to specify the type of BPDU encapsulation to use for all ports added to the STPD (if not otherwise specified).

STPD Identifier
An StpdID is used to identify each STP domain. You assign the StpdID when configuring the domain, and that carrier VLAN of that STPD cannot belong to another STPD. An StpdID must be identical to the VLANid of the carrier VLAN in that STP domain.

NOTE
If an STPD contains at least one port not in 802.1D mode, you must configure the STPD with an StpdID.

STP States
Each port that belongs to a member VLAN participating in STP exists in one of the following states:

Blocking A port in the blocking state does not accept ingress traffic, perform traffic forwarding, or learn MAC source addresses. The port does receive STP BPDUs. During STP initialization, the switch always enters the blocking state.

426

ExtremeWare XOS 11.3 Concepts Guide

Spanning Tree Domains

Listening A port in the listening state does not accept ingress traffic, perform traffic forwarding, or learn MAC source addresses. The port does receive STP BPDUs. This is the first transitional state a port enters after being in the blocking state. The bridge listens for BPDUs from neighboring bridge(s) to determine whether the port should or should not be blocked.

Learning A port in the learning state does not accept ingress traffic or perform traffic forwarding, but it begins to learn MAC source addresses. The port also receives and processes STP BPDUs. This is the second transitional state after listening. From learning, the port will change to either blocking or forwarding.

Forwarding A port in the forwarding state accepts ingress traffic, learns new MAC source addresses, forwards traffic, and receives and processes STP BPDUs.

Disabled A port in the disabled state does not participate in STP; however, it will forward traffic and learn new MAC source addresses.

Binding Ports
The two ways to bind (add) ports to an STPD are: manually and automatically. By default, ports are manually added to an STPD. NOTE
The default VLAN and STPD S0 are already on the switch.

Manually Binding Ports


To manually bind ports, use one of the following commands:

configure stpd <stpd_name> add vlan <vlan_name> ports [all | <port_list>] {[dot1d | emistp | pvst-plus]} configure vlan <vlan_name> add ports [all | <port_list>] {tagged | untagged} {nobroadcast} stpd <stpd_name> {[dot1d | emistp | pvst-plus]}

The first command adds all ports or a list of ports within the specified VLAN to an STPD provided the carrier VLAN already exists on the same set of ports. The second command adds all ports or a list of ports to the specified VLAN and STPD at the same time. If the ports are added to the VLAN but not to the STPD, the ports remain in the VLAN. If the specified VLAN is not the carrier VLAN and the specified ports are not bound to the carrier VLAN, the system displays an error message.

NOTE
The carrier VLANs VLANid must be identical to the StpdID of the STP domain.

If you add a protected VLAN or port, that addition inherits the carrier VLANs encapsulation mode unless you specify the encapsulation mode when you execute the configure stpd add vlan or configure vlan add ports stpd commands. If you specify an encapsulation mode (dot1d, emistp,

ExtremeWare XOS 11.3 Concepts Guide

427

Spanning Tree Protocol or pvst-plus), the STP port mode is changed to match; otherwise, the STP port inherits either the carrier VLANs encapsulation mode on that port or the STPDs default encapsulation mode. To remove ports, use the following command:
configure stpd <stpd_name> delete vlan <vlan_name> ports [all | <port_list>]

If you manually delete a protected VLAN or port, only that VLAN or port is removed. If you manually delete a carrier VLAN or port, all VLANs on that port (both carrier and protected) are deleted from that STPD. To learn more about member VLANs, see Member VLANs on page 424. For more detailed information about these command line interface (CLI) commands, see the ExtremeWare XOS Command Reference Guide.

Automatically Binding Ports


To automatically bind ports to an STPD when the ports are added to a VLAN, use the following command:
enable stpd <stpd_name> auto-bind vlan <vlan_name>

The autobind feature is disabled on user-created STPDs. The autobind feature is enabled on the default VLAN that participates in the default STPD S0. When you issue this command, any port or list of ports that you add to the carrier VLAN are automatically added to the STPD with autobind enabled. In addition, any port or list of ports that you remove from a carrier VLAN are automatically removed from the STPD. This feature allows the STPD to increase or decrease its span as ports are added to or removed from a carrier VLAN.

NOTE
The carrier VLANs VLANid must be identical to the StpdID of the STP domain.

Enabling autobind on a protected VLAN does not expand the boundary of the STPD. If the same set of ports are members of the protected VLAN and the carrier VLAN, protected VLANs are aware of STP state changes. For example, assume you have the following scenario:

Carrier VLAN named v1 v1 contains ports 3:1-3:2 Protected VLAN named v2 v2 contains ports 3:1-3:4

Since v1 contains ports 3:1-3:2, v2 is aware only of the STP changes for ports 3:1 and 3:2, respectively. Ports 3:3 and 3:4 are not part of the STPD, which is why v2 is not aware of any STP changes for those ports. In addition, enabling autobind on a protected VLAN causes ports to be automatically added or removed as the carrier VLAN changes. To remove ports, use the following command:
configure stpd <stpd_name> delete vlan <vlan_name> ports [all | <port_list>]

428

ExtremeWare XOS 11.3 Concepts Guide

Spanning Tree Domains If you manually delete a port from the STPD on a VLAN that has been added by autobind, ExtremeWare XOS records the deletion so that the port does not get automatically added to the STPD after a system restart. To learn more about the member VLANs, see Member VLANs on page 424. For more detailed information about these CLI commands, see the ExtremeWare XOS Command Reference Guide.

Rapid Root Failover


ExtremeWare XOS supports rapid root failover for faster STP failover recovery times in STP 802.1D mode. If the active root port link goes down, ExtremeWare XOS recalculates STP and elects a new root port. The rapid root failover feature allows the new root port to immediately begin forwarding, skipping the standard listening and learning phases. Rapid root failover occurs only when the link goes down and not when there is any other root port failure, such as missing BPDUs. The default setting for this feature is disabled. To enable rapid root failover, use the following command:
enable stpd <stpd_name> rapid-root-failover

To display the configuration, use the following command:


show stpd {<stpd_name> | detail}

STP and Hitless FailoverModular Switches Only


When you install two Management Switch Fabric Module (MSM) modules in a BlackDiamond chassis, one MSM assumes the role of primary and the other MSM assumes the role of backup. The primary executes the switchs management functions, and the backup acts in a standby role. Hitless failover transfers switch management control from the primary to the backup and maintains the state of STP. STP supports hitless failover, and it is enabled by default. NOTE
Beginning with ExtremeWare XOS 11.0, the BlackDiamond 10K supports hitless failover for STP. If you are running an earlier version of ExtremeWare XOS, the BlackDiamond 10K switch does not support STP hitless failover. Beginning with ExtremeWare XOS 11.3, the BlackDiamond 8800 switch (formerly known as Aspen) supports hitless failover for STP. If you are running an earlier version of ExtremeWare XOS, the BlackDiamond 8800 does not support STP hitless failover.

To support hitless failover, the primary MSM replicates STP BPDUs to the backup, which allows the MSMs to run STP in parallel. Although both MSMs receive STP BPDUs, only the primary transmits STP BPDUs to neighboring switches and participates in STP. To initiate hitless failover on a network that utilizes STP: 1 Confirm that the MSMs are synchronized and have identical software and switch configurations using the show switch {detail} command. The output displays the status of the MSMs, with the primary MSM showing MASTER and the backup MSM showing BACKUP (InSync). If the MSMs are not synchronized, proceed to step 2. If the MSMs are synchronized, proceed to step 3.

ExtremeWare XOS 11.3 Concepts Guide

429

Spanning Tree Protocol 2 If the MSMs are not synchronized, replicate all saved images and configuration from the primary to the backup using the synchronize command. 3 Initiate failover using the run msm-failover command. For more detailed information about verifying the status of the MSMs and system redundancy, see Understanding System Redundancy with Dual MSMs InstalledModular Switches Only on page 70. For more information about hitless failover, see Understanding Hitless Failover SupportModular Switches Only on page 74.

STP Configurations
When you assign VLANs to an STPD, pay careful attention to the STP configuration and its effect on the forwarding of VLAN traffic. This section describes three types of STP configurations:

Basic STP Multiple STPDs on a single port (which uses EMISTP) A VLAN that spans multiple STPDs

Basic STP Configuration


This section describes a basic, 802.1D STP configuration. Figure 32 illustrates a network that uses VLAN tagging for trunk connections. The following four VLANs have been defined:

Sales is defined on switch A, switch B, and switch M. Personnel is defined on switch A, switch B, and switch M. Manufacturing is defined on switch Y, switch Z, and switch M Engineering is defined on switch Y, switch Z, and switch M. Marketing is defined on all switches (switch A, switch B, switch Y, switch Z, and switch M).

Two STPDs are defined:


STPD1 contains VLANs Sales and Personnel. STPD2 contains VLANs Manufacturing and Engineering.

The carrier and protected VLANs are also defined:


Sales is the carrier VLAN on STPD1. Personnel is a protected VLAN on STPD1. Manufacturing is a protected VLAN on STPD2. Engineering is the carrier VLAN on STPD2. Marketing is a member of both STPD1 and STPD2 and is a protected VLAN.

430

ExtremeWare XOS 11.3 Concepts Guide

STP Configurations

Figure 32: Multiple STPDs

Sales, Personnel, Marketing


Switch A

Manufacturing, Engineering, Marketing


Switch Y

Switch B

Switch Z Switch M

STPD 1

STPD 2

Sales, Personnel, Manufacturing, Engineering, Marketing

EX_048

When the switches in this configuration boot-up, STP configures each STPD such that the topology contains no active loops. STP could configure the topology in a number of ways to make it loop-free. In Figure 32, the connection between switch A and switch B is put into blocking state, and the connection between switch Y and switch Z is put into blocking state. After STP converges, all the VLANs can communicate, and all bridging loops are prevented. The protected VLAN Marketing, which has been assigned to both STPD1 and STPD2, communicates using all five switches. The topology has no loops, because STP has already blocked the port connection between switch A and switch B and between switch Y and switch Z. Within a single STPD, you must be extra careful when configuring your VLANs. Figure 33 illustrates a network that has been incorrectly set up using a single STPD so that the STP configuration disables the ability of the switches to forward VLAN traffic.

ExtremeWare XOS 11.3 Concepts Guide

431

Spanning Tree Protocol

Figure 33: Incorrect tag-based STPD configuration

Marketing & Sales

Marketing, Sales & Engineering

Switch 1 Switch 2

Switch 3

Sales & Engineering


The tag-based network in Figure 33 has the following configuration:

EX_049

Switch 1 contains VLAN Marketing and VLAN Sales. Switch 2 contains VLAN Engineering and VLAN Sales. Switch 3 contains VLAN Marketing, VLAN Engineering, and VLAN Sales. The tagged trunk connections for three switches form a triangular loop that is not permitted in an STP topology. All VLANs in each switch are members of the same STPD.

STP can block traffic between switch 1 and switch 3 by disabling the trunk ports for that connection on each switch. Switch 2 has no ports assigned to VLAN Marketing. Therefore, if the trunk for VLAN Marketing on switches 1 and 3 is blocked, the traffic for VLAN Marketing will not be able to traverse the switches.

NOTE
If an STPD contains multiple VLANs, all VLANs should be configured on all ports in that domain, except for ports that connect to hosts (edge ports).

432

ExtremeWare XOS 11.3 Concepts Guide

STP Configurations

Multiple STPDs on a Port


Traditional 802.1D STP has some inherent limitations when addressing networks that have multiple VLANs and multiple STPDs. For example, consider the sample depicted in Figure 34.

Figure 34: Limitations of traditional STPD


A B A B

S1

S2

S1

S2

B
EX_050

The two switches are connected by a pair of parallel links. Both switches run two VLANs, A and B. To achieve load-balancing between the two links using the traditional approach, you would have to associate A and B with two different STPDs, called S1 and S2, respectively, and make the left link carry VLAN A traffic while the right link carries VLAN B traffic (or vice versa). If the right link fails, S2 is broken and VLAN B traffic is disrupted. To optimize the solution, you can use the Extreme Multiple Instance Spanning (EMISTP) mode, which allows a port to belong to multiple STPDs. EMISTP adds significant flexibility to STP network design. Referring to Figure 34, using EMISTP, you can configure all four ports to belong to both VLANs. Assuming that S1 and S2 still correspond to VLANs A and B, respectively, you can fine-tune STP parameters to make the left link active in S1 and blocking in S2, while the right link is active in S2 and blocking in S1. Once again, if the right link fails, the left link is elected active by the STP algorithm for S2, without affecting normal switching of data traffic. Using EMISTP, an STPD becomes more of an abstract concept. The STPD does not necessarily correspond to a physical domain; it is better regarded as a vehicle to carry VLANs that have STP instances. Because VLANs can overlap, so do STPDs. However, even if the different STPDs share the entire topology or part of the redundant topology, the STPDs react to topology change events in an independent fashion.

VLAN Spanning Multiple STPDs


Traditionally, the mapping from VLANs to STP instances have been one-to-one or many-to-one. In both cases, a VLAN is wholly contained in a single instance. In practical deployment there are cases in which a one-to-many mapping is desirable. In a typical large enterprise network, for example, VLANs span multiple sites and/or buildings. Each site represents a redundant looped area. However, between any two sites the topology is usually very simple.

ExtremeWare XOS 11.3 Concepts Guide

433

Spanning Tree Protocol Alternatively, the same VLAN may span multiple large geographical areas (because they belong to the same enterprise) and may traverse a great many nodes. In this case, it is desirable to have multiple STP domains operating in a single VLAN, one for each looped area. The justifications include the following:

The complexity of the STP algorithm increases, and performance drops, with the size and complexity of the network. The 802.1D standard specifies a maximum network diameter of seven hops. By segregating a big VLAN into multiple STPDs, you reduce complexity and enhance performance. Local to each site, there may be other smaller VLANs that share the same redundant looped area with the large VLAN. Some STPDs must be created to protect those VLAN. The ability to partition VLANs allows the large VLAN to be piggybacked in those STPDs in a site-specific fashion.

Figure 35 has five domains. VLANs green, blue, brown, and yellow are local to each domain. VLAN red spans all of the four domains. Using a VLAN that spans multiple STPDS, you do not have to create a separate domain for VLAN red. Instead, VLAN red is piggybacked onto those domains local to other VLANs.

Figure 35: VLAN spanning multiple STPDs


VLAN red S1 VLAN green S2

VLAN yellow VLAN red S3 VLAN red VLAN blue

VLAN red VLAN brown S4

EX_051

In addition, the configuration in Figure 35 has these features:

Each site can be administered by a different organization or department within the enterprise. Having a site-specific STP implementation makes the administration more flexible and convenient. Between the sites the connections usually traverse distribution switches in ways that are known beforehand to be safe with STP. In other words, the looped areas are already well-defined.

EMISTP Deployment Constraints


Although EMISTP greatly enhances STP capability, these features must deployed with care. This section discusses configuration issues that, if not followed, could lead to an improper deployment of EMISTP. This section also provides the following restrictive principles to abide by in network design:

Although a physical port can belong to multiple STPDs, any VLAN on that port can be in only one domain. Put another way, a VLAN cannot belong to two STPDs on the same physical port. Although a VLAN can span multiple domains, any LAN segment in that VLAN must be in the same STPD. VLANs traverse STPDs only inside switches, not across links. On a single switch, however, bridge ports for the same VLAN can be assigned to different STPDs. This scenario is illustrated in Figure 36.

434

ExtremeWare XOS 11.3 Concepts Guide

STP Configurations

Figure 36: VLANs traverse domains inside switches


S1 S1

S2 S2

Correct

Wrong

EX_052

The VLAN partition feature is deployed under the premise that the overall inter-domain topology for that VLAN is loop-free. Consider the case in Figure 37, VLAN red (the only VLAN in the figure) spans STPDs 1, 2, and 3. Inside each domain, STP produces a loop-free topology. However, VLAN red is still looped, because the three domains form a ring among themselves.

Figure 37: Looped VLAN topology


Domain 2 Domain 1

Domain 3
EX_053

A necessary (but not sufficient) condition for a loop-free inter-domain topology is that every two domains only meet at a single crossing point.

ExtremeWare XOS 11.3 Concepts Guide

435

Spanning Tree Protocol

Per VLAN Spanning Tree


Switching products that implement Per VLAN Spanning Tree (PVST) have been in existence for many years and are widely deployed. To support STP configurations that use PVST, ExtremeWare XOS has an operational mode called PVST+. NOTE
In this document, PVST and PVST+ are used interchangeably. PVST+ is an enhanced version of PVST that is interoperable with 802.1Q STP. The following discussions are in regard to PVST+, if not specifically mentioned.

STPD VLAN Mapping


Each VLAN participating in PVST+ must be in a separate STPD, and the VLAN number (VLANid) must be the same as the STPD identifier (StpdID). As a result, PVST+ protected VLANs cannot be partitioned. This fact does not exclude other non-PVST+ protected VLANs from being grouped into the same STPD. A protected PVST+ VLAN can be joined by multiple non-PVST+ protected VLANs to be in the same STPD.

Native VLAN
In PVST+, the native VLAN must be peered with the default VLAN on Extreme devices, as both are the only VLAN allowed to send and receive untagged packets on the physical port. Third-party PVST+ devices send VLAN 1 packets in a special manner. ExtremeWare XOS does not support PVST+ for VLAN 1. Therefore, when the switch receives a packet for VLAN 1, the packet is dropped. When a PVST+ instance is disabled, the fact that PVST+ uses a different packet format raises an issue. If the STPD also contains ports not in PVST+ mode, the flooded packet has an incompatible format with those ports. The packet is not recognized by the devices connected to those ports.

Rapid Spanning Tree Protocol


The Rapid Spanning Tree Protocol (RSTP), IEEE 802.1w provides an enhanced spanning tree algorithm that improves the convergence speed of bridged networks. RSTP takes advantage of point-to-point links in the network and actively confirms that a port can safely transition to the forwarding state without relying on any timer configurations. If a network topology change or failure occurs, RSTP rapidly recovers network connectivity by confirming the change locally before propagating that change to other devices across the network. For broadcast links, there is no difference in convergence time between STP and RSTP. RSTP supersedes legacy STP protocols, supports the existing STP parameters and configurations, and allows for seamless interoperability with legacy STP.

436

ExtremeWare XOS 11.3 Concepts Guide

Rapid Spanning Tree Protocol

RSTP Concepts
This section describes important RSTP concepts.

Port Roles
RSTP uses information from BPDUs to assign port roles for each LAN segment. Port roles are not userconfigurable. Port role assignments are determined based on the following criteria:

A unique bridge identifier (MAC address) associated with each bridge The path cost associated with each bridge port A port identifier associated with each bridge port

RSTP assigns one of four port roles to bridge ports in the network, as described in Table 59.

Table 59: RSTP port roles


Port Role Root Description Provides the shortest path to the root bridge. Each bridge has only one root port; the root bridge does not have a root port. If a bridge has two or more ports with the same path cost, the port with the best port identifier becomes the root port. Provides the shortest path connection to the root bridge for the attached LAN segment. To prevent loops in the network, there is only one designated port on each LAN segment. To select the designated port, all bridges that are connected to a particular segment listen to each others BPDUs and agree on the bridge sending the best BPDU. The corresponding port on that bridge becomes the designated port. If there are two or more ports connected to the LAN, the port with the best port identifier (lowest MAC address) becomes the designated port. Provides an alternate path to the root bridge and the root port. Supports the designated port on the same attached LAN segment. Backup ports exist only when the bridge is connected as a self-loop or to a shared-media segment.

Designated

Alternate Backup

When RSTP stabilizes, all:


Root ports and designated ports are in the forwarding state. Alternate ports and backup ports are in the blocking state.

RSTP makes the distinction between the alternate and backup port roles to describe the rapid transition of the alternate port to the forwarding state if the root port fails. Ports that connect to non-STP devices are edge ports. Edge ports do not participate in RSTP, and their role is not confirmed. Edge ports immediately enter the forwarding state.

Link Types
With RSTP, you can configure the link type of a port in an STPD. RSTP tries to rapidly move designated point-to-point links into the forwarding state when a network topology change or failure occurs. For rapid convergence to occur, the port must be configured as a point-to-point link.

ExtremeWare XOS 11.3 Concepts Guide

437

Spanning Tree Protocol Table 60 describes the link types.

Table 60: RSTP link types


Port Link Type Auto Description Specifies the switch to automatically determine the port link type. An auto link behaves like a point-to-point link if the link is in full-duplex mode or if link aggregation is enabled on the port. Otherwise, the link behaves like a broadcast link used for 802.1w configurations. Specifies a port that does not have a bridge attached. An edge port is placed and held in the STP forwarding state unless a BPDU is received by the port. Specifies a port attached to a LAN segment with more than two bridges. A port with a broadcast link type cannot participate in rapid reconfiguration. By default, all ports are broadcast links. Specifies a port attached to a LAN segment with only two bridges. A port with port-to-port link type can participate in rapid reconfiguration. Used for 802.1w configurations.

Edge Broadcast

Point-to-point

Configuring Link Types. By default, all ports are broadcast links. To configure the ports in an STPD, use the following command:
configure stpd <stpd_name> ports link-type [auto | broadcast | edge | point-to-point] <port_list>

Where the following is true:

autoConfigures the ports as auto links. If the link is in full-duplex mode or if link aggregation is enabled on the port, an auto link behaves like a point-to-point link. edgeConfigures the ports as edge ports. point-to-pointConfigures the ports for an RSTP environment.

To change the existing configuration of a port in an STPD, and return the port to factory defaults, use the following command:
unconfigure stpd <stpd_name> ports link-type <port_list>

To display detailed information about the ports in an STPD, use the following command:
show stpd <stpd_name> ports {[detail | <port_list> {detail}]}

RSTP Timers
For RSTP to rapidly recover network connectivity, RSTP requires timer expiration. RSTP derives many of the timer values from the existing configured STP timers to meet its rapid recovery requirements rather than relying on additional timer configurations. Table 61 describes the user-configurable timers, and Table 62 describes the timers that are derived from other timers and not user-configurable.

Table 61: User-configurable timers


Timer Hello Description The root bridge uses the hello timer to send out configuration BPDUs through all of its forwarding ports at a predetermined, regular time interval. The default value is 2 seconds. The range is 1 to 10 seconds.

438

ExtremeWare XOS 11.3 Concepts Guide

Rapid Spanning Tree Protocol

Table 61: User-configurable timers (Continued)


Timer Forward delay Description A port moving from the blocking state to the forwarding state uses the forward delay timer to transition through the listening and learning states. In RSTP, this timer complements the rapid configuration behavior. If none of the rapid rules are in effect, the port uses legacy STP rules to move to the forwarding state. The default is 15 seconds. The range is 4 to 30 seconds.

Table 62: Derived timers


Timer TCN Description The root port uses the topology change notification (TCN) timer when it detects a change in the network topology. The TCN timer stops when the topology change timer expires or upon receipt of a topology change acknowledgement. The default value is the same as the value for the bridge hello timer. The topology change timer determines the total time it takes the forwarding ports to send configuration BPDUs. The default value for the topology change timer depends upon the mode of the port: 802.1D modeThe sum of the forward delay timer value (default value is 15 seconds; range of 4 to 30 seconds) and the maximum age timer value (default value is 20 seconds; range of 6 to 40 seconds). 802.1w modeDouble the hello timer value (default value is 4 seconds) Message age A port uses the message age timer to time out receiving BPDUs. When a port receives a superior or equal BPDU, the timer restarts. When the timer expires, the port becomes a designated port and a configuration update occurs. If the bridge operates in 1w mode and receives an inferior BPDU, the timer expires early. The default value is the same as the STPD bridge max age parameter. A port uses the hold timer to restrict the rate that successive BPDUs can be sent. The default value is the same as the value for the bridge hello timer. The timer starts when a port leaves the backup role. When this timer is running, the port cannot become a root port. The default value is double the hello time (4 seconds). The timer starts when a port leaves the root port role. When this timer is running, another port cannot become a root port unless the associated port is put into the blocking state. The default value is the same as the forward delay time.

Topology change

Hold Recent backup

Recent root

The protocol migration timer is neither user-configurable nor derived; it has a set value of 3 seconds. The timer starts when a port transitions from STP (802.1D) mode to RSTP (802.1w) mode and viceversa. This timer must expire before further mode transitions can occur.

RSTP Operation
In an RSTP environment, a point-to-point link LAN segment has two bridges. A switch that considers itself the unique, designated bridge for the attached LAN segment sends a propose message to the other bridge to request a confirmation of its role. The other bridge on that LAN segment replies with an agree message if it agrees with the proposal. The receiving bridge immediately moves its designated port into the forwarding state. Before a bridge replies with an agree message, it reverts all of its designated ports into the blocking state. This introduces a temporary partition into the network. The bridge then sends another propose message on all of its designated ports for further confirmation. Because all of the connections are

ExtremeWare XOS 11.3 Concepts Guide

439

Spanning Tree Protocol blocked, the bridge immediately sends an agree message to unblock the proposing port without having to wait for further confirmations to come back or without the worry of temporary loops. Beginning with the root bridge, each bridge in the network engages in the exchange of propose and agree messages until they reach the edge ports. Edge ports connect to non-STP devices and do not participate in RSTP. Their role does not need to be confirmed. If an edge port receives a BPDU, it enters an inconsistency state. An inconsistency state puts the edge port into the blocking state and starts the message age timer. Every time the edge port receives a BPDU, the message age timer restarts. The edge port remains in the blocking state until no further BPDUs are received and the message age timer expires. RSTP attempts to transition root ports and designated ports to the forwarding state and alternate ports and backup ports to the blocking state as rapidly as possible. A port transitions to the forwarding state if any of the following is true. The port:

Has been in either a root or designated port role long enough that the spanning tree information supporting this role assignment has reached all of the bridges in the network. NOTE
RSTP is backward compatible with STP, so if a port does not move to the forwarding state with any of the RSTP rapid transition rules, a forward delay timer starts and STP behavior takes over.

Is now a root port and no other ports have a recent role assignment that contradicts with its root port role. Is a designated port and attaches to another bridge by a point-to-point link and receives an agree message from the other bridge port. Is an edge port. An edge port is a port connected to a non-STP device and is in the forwarding state.

The following sections provide more information about RSTP behavior.

Root Port Rapid Behavior


In Figure 38, the diagram on the left displays the initial network topology with a single bridge having the following:

Two ports are connected to a shared LAN segment. One port is the designated port. One port is the backup port.

The diagram on the right displays a new bridge that:


Is connected to the LAN segment. Has a superior STP bridge priority. Becomes the root bridge and sends a BPDU to the LAN that is received by both ports on the old bridge.

440

ExtremeWare XOS 11.3 Concepts Guide

Rapid Spanning Tree Protocol

Figure 38: Example of root port rapid behavior


Inital topology Bridge
Backup port Designated port Backup port

New topology Bridge


Designated port

LAN segment

Superior STP bridge priority

Root bridge
EX_054

If the backup port receives the BPDU first, STP processes this packet and temporarily elects this port as the new root port while the designated ports role remains unchanged. If the new root port is immediately put into the forwarding state, there is a loop between these two ports. To prevent this type of loop from occurring, the recent backup timer starts. The root port transition rule does not allow a new root port to be in the forwarding state until the recent backup timer expires. Another situation may arise if you have more than one bridge and you lower the port cost for the alternate port, which makes it the new root port. The previous root port is now an alternate port. Depending on your STP implementation, STP may set the new root port to the forwarding state before setting the alternate port to the blocking state. This may cause a loop. To prevent this type of loop from occurring, the recent root timer starts when the port leaves the root port role. The timer stops if the port enters the blocking state. RSTP requires that the recent root timer stop on the previous root port before the new root port can enter the forwarding state.

Designated Port Rapid Behavior


When a port becomes a new designated port, or the STP priority changes on an existing designated port, the port becomes an unsynced designated port. In order for an unsynced designated port to rapidly move into the forwarding state, the port must propose a confirmation of its role on the attached LAN segment (unless the port is an edge port). Upon receiving an agree message, the port immediately enters the forwarding state. If the receiving bridge does not agree and it has a superior STP priority, the receiving bridge replies with its own BPDU. Otherwise, the receiving bridge keeps silent, and the proposing port enters the forwarding state and starts the forward delay timer. The link between the new designated port and the LAN segment must be a point-to-point link. If there is a multi-access link, the propose message is sent to multiple recipients. If only one of the recipients agrees with the proposal, the port can erroneously enter the forwarding state after receiving a single agree message.

ExtremeWare XOS 11.3 Concepts Guide

441

Spanning Tree Protocol

Receiving Bridge Behavior


The receiving bridge must decide whether or not to accept a proposal from a port. Upon receiving a proposal for a root port, the receiving bridge:

Processes the BPDU and computes the new STP topology. Synchronizes all of the designated ports if the receiving port is the root port of the new topology. Puts all unsynced, designated ports into the blocking state. Sends down further propose messages. Sends back an agree message through the root port.

If the receiving bridge receives a proposal for a designated port, the bridge replies with its own BPDU. If the proposal is for an alternate or backup port, the bridge keeps silent.

Propagating Topology Change Information


When a change occurs in the topology of the network, such events are communicated through the network. In an RSTP environment, only non-edge ports entering the forwarding state cause a topology change. A loss of network connectivity is not considered a topology change; however, a gain in network connectivity must be communicated. When an RSTP bridge detects a topology change, that bridge starts the topology change timer, sets the topology change flag on its BPDUs, floods all of the forwarding ports in the network (including the root ports), and flushes the learned MAC address entries.

Rapid Reconvergence
This section describes the RSTP rapid behavior following a topology change. In this example, the bridge priorities are assigned based on the order of their alphabetical letters; bridge A has a higher priority than bridge F. Suppose we have a network, as shown in Figure 39, with six bridges (bridge A through bridge F) where the following is true:

Bridge A is the root bridge. Bridge D contains an alternate port in the blocking state. All other ports in the network are in the forwarding state.

442

ExtremeWare XOS 11.3 Concepts Guide

Rapid Spanning Tree Protocol

Figure 39: Initial network configuration

A
A,0

B
A,1

C
A,2

F
A,1
Designated port Root port

E
A,2
Blocked port

D
A,3

EX_055a

The following steps describe how the network reconverges. 1 If the link between bridge A and bridge F goes down, bridge F detects the root port is down. At this point, bridge F:

Immediately disables that port from the STP. Performs a configuration update. Considers itself the new root bridge. Sends a BPDU message on its designated port to bridge E.

As shown in Figure 40, after the configuration update, bridge F:


Figure 40: Down link detected

A
A,0
Down link

B
A,1

C
A,2

BPDU

F
F,0
Designated port Root port

E
A,2

D
A,3

EX_055b

2 Bridge E believes that bridge A is the root bridge. When bridge E receives the BPDU on its root port from bridge F, bridge E:

Determines that it received an inferior BPDU. Immediately begins the max age timer on its root port. Performs a configuration update.

ExtremeWare XOS 11.3 Concepts Guide

443

Spanning Tree Protocol As shown in Figure 41, after the configuration update, bridge E:

Regards itself as the new root bridge. Sends BPDU messages on both of its designated ports to bridges F and D, respectively.

Figure 41: New root bridge selected

A
A,0

B
A,1
Designated port

C
A,2

F
F,0

E
E,0
BPDU

D
A,3

Root port

EX_055c

3 As shown in Figure 42, when bridge F receives the superior BPDU and configuration update from bridge E, bridge F:

Decides that the receiving port is the root port. Determines that bridge E is the root bridge.

Figure 42: Communicating new root bridge status to neighbors

A
A,0

B
A,1
Designated port

C
A,2

F
E,1

E
E,0

D
A,3

Root port

EX_055d

4 Bridge D believes that bridge A is the root bridge. When bridge D receives the BPDU from bridge E on its alternate port, bridge D:

Immediately begins the max age timer on its alternate port. Performs a configuration update.

444

ExtremeWare XOS 11.3 Concepts Guide

Rapid Spanning Tree Protocol As shown in Figure 43, after the configuration update, bridge D:

Moves the alternate port to a designated port. Sends a propose message to bridge E to solicit confirmation of its designated role and to rapidly move the port into the designated state.

Figure 43: Sending a propose message to confirm a port role

A
A,0

B
A,1
Designated port

C
A,2

F
E,1

E
E,0
Propose BPDU

D
A,3

Root port

EX_055e

5 Upon receiving the proposal, bridge E (as shown in Figure 44):


Performs a configuration update. Changes its receiving port to a root port. The existing designated port enters the blocking state.

Bridge E then sends:


A propose message to bridge F. An agree message from its root port to bridge D.

Figure 44: Communicating port status to neighbors

A
A,0
Designated port

B
A,1
Root port

C
A,2

F
E,1

E
A,4
Agree BPDU

D
A,3

EX_055f

ExtremeWare XOS 11.3 Concepts Guide

445

Spanning Tree Protocol 6 To complete the topology change (as shown in Figure 45):

Bridge D moves the port that received the agree message into the forwarding state. Bridge F confirms that its receiving port (the port that received the propose message) is the root port, and immediately replies with an agree message to bridge E to unblock the proposing port.

Figure 45: Completing the topology change

A
A,0

B
A,1
Root port Designated port

C
A,2

F
A,5

E
A,4

D
A,3
EX_055g

Figure 46 displays the new topology.

Figure 46: Final network configuration

A
A,0

B
A,1
Root port Designated port

C
A,2

F
A,5

E
A,4

D
A,3
EX_055h

Compatibility With STP (802.1D)


RSTP interoperates with legacy STP protocols; however, the rapid convergence benefits are lost when interacting with legacy STP bridges. Each RSTP bridge contains a port protocol migration state machine to ensure that the ports in the STPD operate in the correct, configured mode. The state machine is a protocol entity within each bridge configured to run in 802.1w mode. For example, a compatibility issue occurs if you configure 802.1w mode and the bridge receives an 802.1D BPDU on a port. The receiving port starts the protocol migration timer and remains in 802.1D mode until the bridge stops receiving 802.1d BPDUs. Each time the bridge receives an 802.1D BPDU, the timer restarts. When the port migration timer expires, no more 802.1D BPDUs have been received, and the bridge returns to its configured setting, which is 802.1w mode.

446

ExtremeWare XOS 11.3 Concepts Guide

STP Rules and Restrictions

STP Rules and Restrictions


This section summarizes the rules and restrictions for configuring STP as follows:

The carrier VLAN must span all ports of the STPD. The StpdID must be the VLANid of the carrier VLAN; the carrier VLAN cannot be partitioned. A default VLAN cannot be partitioned. If a VLAN traverses multiple STPDs, the VLAN must be tagged. An STPD can carry, at most, one VLAN running in PVST+ mode, and its StpdID must be identical with that VLANid. In addition, the PVST+ VLAN cannot be partitioned. The default VLAN of a PVST+ port must be identical with the native VLAN on the PVST+ device connected to that port. If an STPD contains both PVST+ and non-PVST+ ports, that STPD must be enabled. If that STPD is disabled, the BPDUs are flooded in the format of the incoming STP port, which may be incompatible with those of the connected devices. The 802.1D ports must be untagged; and the EMISTP/PVST+ ports must be tagged in the carrier VLAN. An STPD with multiple VLANs must contain only VLANs that belong to the same virtual router instance. Automatically adding ports to an STPD (known as STP autobind) cannot be configured on a Netlogin VLAN. STP cannot be configured on the following ports:

A mirroring target port. A software-controlled redundant port. A Netlogin port.

Configuring STP on the Switch


To configure basic STP: 1 Create one or more STPDs using the following command:
create stpd <stpd_name>

2 Add one or more VLANs to the STPD using the following command:
configure stpd <stpd_name> add vlan <vlan_name> ports [all | <port_list>] {[dot1d | emistp | pvst-plus]}

3 Define the carrier VLAN using the following command:


configure stpd <stpd_name> tag <stpd_tag>

NOTE
The carrier VLANs VLANid must be identical to the StpdID of the STPD.

4 Enable STP for one or more STPDs using the following command:
enable stpd {<stpd_name>}

After you have created the STPD, you can optionally configure STP parameters for the STPD.

ExtremeWare XOS 11.3 Concepts Guide

447

Spanning Tree Protocol

NOTE
You should not configure any STP parameters unless you have considerable knowledge and experience with STP. The default STP parameters are adequate for most networks.

The following parameters can be configured on each STPD:


Hello time Forward delay Max age Bridge priority StpdID

The following parameters can be configured on each port:


Path cost Port priority Port mode NOTE

The device supports the RFC 1493 Bridge MIB, RSTP-03, and Extreme Networks STP MIB. Parameters of the s0 default STPD support RFC 1493 and RSTP-03. Parameters of any other STPD support the Extreme Networks STP MIB.

NOTE
If an STPD contains at least one port not in 802.1D (dot1D) mode, the STPD must be configured with an StpdID.

STP Configuration Examples


This section provides three configuration examples:

Basic 802.1D STP EMISTP RSTP 802.1w

Basic 802.1D Configuration Example


The following example:

Removes ports from the VLAN Default that will be added to VLAN Engineering. Creates the VLAN Engineering. Configures the VLANid. Adds ports to the VLAN Engineering. Creates an STPD named Backbone_st.

448

ExtremeWare XOS 11.3 Concepts Guide

STP Configuration Examples


Configures the default encapsulation mode of dot1d for all ports added to STPD Backbone_st. Enables autobind to automatically add or remove ports from the STPD. Assigns the Engineering VLAN to the STPD. Assigns the carrier VLAN. Enables STP.

configure vlan default delete ports 2:5-2:10 create vlan engineering configure vlan engineering tag 150 configure vlan engineering add ports 2:5-2:10 untagged create stpd backbone_st configure stpd backbone_st default-encapsulation dot1d enable stpd backbone_st auto-bind vlan engineering configure stpd backbone_st tag 150 enable stpd backbone_st

By default, the port encapsulation mode for user-defined STPDs is emistp. In this example, you set it to dot1d.

EMISTP Configuration Example


Figure 47 is an example of EMISTP.

Figure 47: EMISTP configuration example

VLAN red S1 VLAN green S2

VLAN yellow VLAN red S3 VLAN red VLAN blue

VLAN red VLAN brown S4

EX_051

NOTE
By default, all ports added to a user-defined STPD are in emistp mode, unless otherwise specified.

The following commands configure the switch located between S1 and S2:
create vlan red configure red tag 100 configure red add ports 1:1-1:4 tagged create vlan green configure green tag 200

ExtremeWare XOS 11.3 Concepts Guide

449

Spanning Tree Protocol


configure green add ports 1:1-1:2 tagged create vlan yellow configure yellow tag 300 configure yellow add ports 1:3-1:4 tagged create stpd s1 configure stpd s1 add green ports all configure stpd s1 tag 200 configure stpd s1 add red ports 1:1-1:2 emistp enable stpd s1 create stpd s2 configure stpd s2 add yellow ports all configure stpd s2 tag 300 configure stpd s2 add red ports 1:3-1:4 emistp enable stpd s2

RSTP 802.1w Configuration Example


Figure 48 is an example of a network with multiple STPDs that can benefit from RSTP. For RSTP to work, you need to do the following:

Create an STPD. Configure the mode of operation for the STPD. Create the VLANs and assign the VLANid and the VLAN ports. Assign the carrier VLAN. Add the protected VLANs to the STPD. Configure the port link types. Enable STP.

450

ExtremeWare XOS 11.3 Concepts Guide

STP Configuration Examples

Figure 48: RSTP example

Sales, Personnel, Marketing


Switch A

Manufacturing, Engineering, Marketing


Switch Y

Switch B

Switch Z Switch M

STPD 1

STPD 2

Sales, Personnel, Manufacturing, Engineering, Marketing

EX_048

ExtremeWare XOS 11.3 Concepts Guide

451

Spanning Tree Protocol In this example, the commands configure switch A in STPD1 for rapid reconvergence. Use the same commands to configure each switch and STPD in the network.
create stpd stpd1 configure stpd stpd1 mode dot1w create vlan sales create vlan personnel create vlan marketing configure vlan sales tag configure vlan personnel configure vlan marketing configure vlan sales add configure vlan personnel configure vlan marketing

100 tag 200 tag 300 ports 1:1,2:1 tagged add ports 1:1,2:1 tagged add ports 1:1,2:1 tagged

configure stpd stpd1 add vlan sales ports all configure stpd stpd1 add vlan personnel ports all configure stpd stpd1 add vlan marketing ports all configure stpd stpd1 ports link-type point-to-point 1:1,2:1 configure stpd stpd1 tag 100 enable stpd stpd1

Displaying STP Settings


To display STP settings, use the following command:
show stpd {<stpd_name> | detail}

This command displays the following information:


STPD name STPD state STPD mode of operation Rapid Root Failover Tag Ports Active VLANs Bridge Priority Bridge ID Designated root STPD configuration information

To display the STP state of a port, use the following command:


show stpd <stpd_name> ports {[detail | <port_list> {detail}]}

452

ExtremeWare XOS 11.3 Concepts Guide

Displaying STP Settings This command displays the following information:


STPD port configuration STPD port mode of operation STPD path cost STPD priority STPD state (root bridge, and so on) Port role (root bridge, edge port, and so on) STPD port state (forwarding, blocking, and so on) Configured port link type Operational port link type

If you have a VLAN that spans multiple STPDs, use the show vlan <vlan_name> stpd command to display the STP configuration of the ports assigned to that specific VLAN.

The command displays the following: STPD port configuration STPD port mode of operation STPD path cost STPD priority STPD state (root bridge, and so on) Port role (root bridge, edge port, and so on) STPD port state (forwarding, blocking, and so on) Configured port link type Operational port link type

ExtremeWare XOS 11.3 Concepts Guide

453

Spanning Tree Protocol

454

ExtremeWare XOS 11.3 Concepts Guide

21 Extreme Standby Router Protocol


This chapter covers the following topics:

Overview of ESRP on page 455 ESRP Concepts on page 456 Determining the ESRP Master on page 462 Configuring an ESRP Domain on a Switch on page 466 Advanced ESRP Features on page 469 Displaying ESRP Information on page 476 Using ELRP with ESRP on page 476 ESRP Examples on page 479 ESRP Cautions on page 484

Overview of ESRP
The Extreme Standby Router Protocol (ESRP) is a feature of ExtremeWare XOS that allows multiple switches to provide redundant routing services to users. From the workstations perspective, there is only one default router (that has one IP address and one MAC address), so address resolution protocol (ARP) cache entries in client workstations do not need to be refreshed or aged out. ESRP is available only on Extreme Networks switches. In addition to providing Layer 3 routing redundancy for IP and IPX, ESRP also provides Layer 2 redundancy. You can use these layered redundancy features in combination or independently. You do not have to configure the switch for routing to make valuable use of ESRP. The Layer 2 redundancy features of ESRP offer fast failure recovery and provide for dual-homed system design. In some instances, depending on network system design, ESRP can provide better resiliency than using Spanning Tree Protocol (STP) or Virtual Router Redundancy Protocol (VRRP). Extreme Networks recommends that all switches participating in ESRP run the same version of ExtremeWare XOS. This section provides an overview of the following topics:

ESRP Modes of Operation on page 456 ESRP and ELRP on page 456 Reasons to Use ESRP on page 456

ExtremeWare XOS 11.3 Concepts Guide

455

Extreme Standby Router Protocol

ESRP Modes of Operation


ExtremeWare XOS has two modes of ESRP operation: standard and extended. Select standard ESRP if your network contains some switches running ExtremeWare, others running ExtremeWare XOS, and a combination of those switches participating in ESRP. Standard ESRP is backward compatible with and supports the ESRP functionality of ExtremeWare. Select extended ESRP if your network contains switches running only ExtremeWare XOS. Extended mode ESRP supports and is compatible with switches running ExtremeWare XOS. By default, ExtremeWare XOS operates in extended mode. In addition to the modes of operation, ESRP has an auto toggle feature. Depending on the mode of operation configured on the neighbor switch, the mode of operation at this end will toggle to the same mode of operation as the neighbor. For more detailed information about the ESRP modes of operation, see Standard and Extended ESRP on page 459.

ESRP and ELRP


Support for the Extreme Loop Recovery Protocol (ELRP) was introduced in ExtremeWare XOS 11.1. ELRP allows you to prevent, detect, and recover from Layer 2 loops in the network. For more information about configuring ELRP in an ESRP environment, see Using ELRP with ESRP on page 476. For more information about standalone ELRP, see Using Standalone ELRP to Perform Loop Tests on page 620.

Reasons to Use ESRP


You can use ESRP to achieve edge-level or aggregation-level redundancy. Deploying ESRP in this area of the network allows you to simplify your network design, which is important in designing a stable network. ESRP also works well in meshed networks where Layer 2 loop protection and Layer 3 redundancy are simultaneously required.

ESRP Concepts
You configure ESRP on a per domain basis on each switch. A maximum of two switches can participate in providing redundant Layer 3 or Layer 2 services to a single Virtual LAN (VLAN). If you configure and use ESRP groups, more than two switches can provide redundant Layer 2 or Layer 3 services to a single VLAN. The switches exchange keep-alive packets for each VLAN independently. Only one switch (the master) can actively provide Layer 3 routing and/or Layer 2 switching for each VLAN. This switch handles the forwarding, ARP requests, and routing for this particular VLAN. Other participating switches for the VLAN are in slave mode waiting for an ESRP state change. For a VLAN within an ESRP domain, each participating switch uses the same MAC address and must be configured with the same IP address or IPX NetID. It is possible for one switch to be a master switch for one or more VLANs while being a slave switch for other VLANs, thus allowing the load to be split across participating switches.

456

ExtremeWare XOS 11.3 Concepts Guide

ESRP Concepts Figure 49 displays a basic ESRP topology.

Figure 49: Example of a basic ESRP topology

ESRP Core Switch #1 State Domain Group 0 Master corpnet1 0 Master corpnet2 0 Slave corpnet3

ESRP Core Switch #2 State Domain Group 0 Slave corpnet1 0 Slave corpnet2 0 Master corpnet3

Corpnet1, Corpnet2 advertised ESRP virtual mac: 00:E0:2B:00:00:80

Corpnet3 advertised virtual mac: 00:E0:2B:00:00:80

ESRP-aware

ESRP-aware

ESRP-aware

EX_099

NOTE
If you configure the Open Shortest Path First (OSPF) routing protocol and ESRP, you must manually configure an OSPF router identifier (ID). Be sure that you configure a unique OSPF router ID on each switch running ESRP. For more information on configuring OSPF, see Chapter 25.

To participate in ESRP, the following must be true:


A VLAN can belong to only one ESRP domain. The IP address for the VLANs participating in an ESRP domain must be identical. All switches in the ESRP network must use the same election algorithm, otherwise loss of connectivity, broadcast storms, or other unpredictable behavior may occur. If you have an untagged master VLAN, you must specify an ESRP domain ID. The domain ID must be identical on all switches participating in ESRP for that particular domain. If you have a tagged master VLAN, ESRP uses the 802.1Q tag (VLANid) of the master VLAN for the ESRP domain ID. If you do not use the VLANid as the domain ID, you must specify a different domain ID. As previously described, the domain ID must be identical on all switches participating in ESRP for that particular domain.

ExtremeWare XOS 11.3 Concepts Guide

457

Extreme Standby Router Protocol

ESRP-Aware Switches
Extreme Networks switches that are not actively participating in ESRP but are connected on a network that has other Extreme Networks switches running ESRP are ESRP-aware. When ESRP-aware switches are attached to ESRP-enabled switches, the ESRP-aware switches reliably perform failover and failback scenarios in the prescribed recovery times. If Extreme Networks switches running ESRP are connected to Layer 2 switches that are manufactured by third-party vendors, the failover times for traffic local to that segment may appear longer, depending on the application involved and the FDB timer used by the other vendors Layer 2 switch. ESRP can be used with Layer 2 switches from other vendors, but the recovery times vary. The VLANs associated with the ports connecting an ESRP-aware switch to an ESRP-enabled switch must be configured using an 802.1Q tag on the connecting port; or, if only a single VLAN is involved, as untagged using the protocol filter any. ESRP will not function correctly if the ESRP-aware switch interconnection port is configured for a protocol-sensitive VLAN using untagged traffic. You can also use port restart in this scenario. For more information about port restart, see ESRP Port Restart on page 473.

Configuring ESRP-Aware Switches


For an Extreme Networks switch to be ESRP-aware, you must create an ESRP domain on the aware switch, add a master VLAN to that ESRP domain, and configure a domain ID, if necessary. To participate as an ESRP-aware switch, the following must be true:

The ESRP domain name must identical on all switches (ESRP-enabled and ESRP-aware) participating in ESRP for that particular domain. The master VLAN name and IP address must be identical on all switches (ESRP-enabled and ESRPaware) participating in ESRP for that particular domain. The domain ID must be identical on all switches (ESRP-enabled or ESRP-aware) participating in ESRP for that particular domain.

If you have an untagged master VLAN, you must specify an ESRP domain ID. If you have a tagged master VLAN, ESRP uses the 802.1Q tag (VLANid) of the master VLAN for the ESRP domain ID. If you do not use the VLANid as the domain ID, you must specify a different domain ID. NOTE

Before you begin, make a note of the ESRP domain parameters on the ESRP-enabled switch. That way you can easily refer to your notes while creating the ESRP domain on the ESRP-aware switch.

To configure an ESRP-aware switch, complete the following steps: 1 Create an ESRP domain using the create esrp <esrpDomain> command. After you create the domain, do not enable it. 2 Add a master VLAN to your ESRP domain using the configure esrp <esrpDomain> add master <vlan_name> command. You are only required to add a master VLAN to the ESRP domain. You are not required to add member VLANs to the ESRP domain. 3 If necessary, configure a domain ID for the ESRP domain using the configure esrp <esrpDomain> domain-id <number> command.

458

ExtremeWare XOS 11.3 Concepts Guide

ESRP Concepts

Displaying ESRP-Aware Information


To display ESRP-aware information, use the following command:
show esrp {<name>}

The display includes the group number and MAC address for the master of the group, as well as the age of the information.

Standard and Extended ESRP


ESRP has two modes of operation: standard and extended. By default, ExtremeWare XOS operates in extended mode. To configure a different mode of operation, use the following command:
configure esrp mode [extended | standard]

Standard mode is backward compatible with and supports the ESRP functionality of switches running ExtremeWare. ESRP functionality available in extended mode is not applicable in standard mode. Use standard mode if your network contains both switches running ExtremeWare and switches running ExtremeWare XOS participating in ESRP. Extended mode supports and is compatible with switches running ExtremeWare XOS while participating in ESRP. Use extended mode if your network contains only switches running ExtremeWare XOS. The following list describes the major differences in behavior between standard and extended mode:

Handshaking In standard mode, events such as link flapping cause the ESRP master switch to generate a large number of packets and to increase processing time. To prevent this, extended mode supports handshaking. Handshaking occurs when a switch requests a state change, forces its neighbor to acknowledge the change, and the neighbor sends an acknowledgement to the requesting switch. For example, if a slave switch wants to become the master, it enters the pre-master state, notifies the neighbor switch, and forces the neighbor to acknowledge the change. The neighbor then sends an acknowledgement back to the slave switch. While the requesting switch waits for the acknowledgements, future updates are suppressed to make sure the neighbor does not act on incorrect data.

Stickiness In standard mode, if an event causes the ESRP master switch to fail over to the slave, it becomes the new master. If another event occurs, the new master switch returns to the slave and you have experienced two network interruptions. To prevent this, extended mode supports the sticky election metric. The default election algorithm uses the sticky metric. For example, if an event causes the ESRP master switch to fail over to the slave, it becomes the new master and has a higher sticky value. If another event occurs, for example adding active ports to the slave, the new master does not fail back to the original master even if the slave has more active ports. After sticky is set on the master, regardless of changes to its neighbors election algorithm, the new master retains its position. Sticky algorithms provide for fewer network interruptions than non-sticky algorithms. Sticky is set only on the master switch.

Port weight In standard mode, the port count calculation does not take into account the available bandwidth of the ports. For example, a switch with a one Gigabit Ethernet uplink may be unable to become master because another switch has a load-shared group of four fast Ethernet links. The active port count only consider the number of active ports, not the bandwidth of those ports.

ExtremeWare XOS 11.3 Concepts Guide

459

Extreme Standby Router Protocol In extended mode, the active port count considers the number of active ports and the port weight configuration also considers the bandwidth of those ports. You enable port weight only on the loadshared master port.

Domain ID In standard mode, ESRP packets do not contain domain information; therefore, the only information about the packet comes from the receiving port. The concept of domain ID is applicable only to extended mode. A domain ID in the packet clearly classifies the packet, associates a received ESRP PDU to a specific ESRP domain, and tells the receiving port where the packet came from. In extended mode, you must have a domain ID for each ESRP domain. Each switch participating in ESRP for a particular domain must have the same domain ID configured. The ESRP domain ID is determined from one of the following user-configured parameters:

ESRP domain number created with the configure esrp <esrpDomain> domain-id <number> command 802.1Q tag (VLANid) of the tagged master VLAN

Hello messages In standard mode, both the master switch and slave switch send periodic ESRP hello messages. This causes an increase in packet processing by both the master and slave. In extended mode, the master switch sends periodic ESRP hello messages. This reduces the amount of packet processing, increases the amount of available link bandwidth, and does not impact communicating state changes between switches.

In addition to the modes of operation, ESRP has an auto toggle feature. Depending on the mode of operation configured on the neighbor switch, the mode of operation at this end will toggle to the same mode of operation as the neighbor. For example, if you use the default modeextendedand your ESRP domain contains a switch running ExtremeWare XOS that detects a neighbor switch running ExtremeWare, the mode automatically changes to standard for that domain. This action causes the switch to enter the neutral state and re-elect the ESRP master. Since you are using the default mode of operation, and the switch running ExtremeWare XOS detected a neighbor switch running ExtremeWare, the ExtremeWare XOS switch toggles to standard mode although the configured mode of operation remains as extended.

ESRP Domains
ESRP domains allow you to configure multiple VLANs under the control of a single instance of the ESRP protocol. By grouping multiple VLANs under one ESRP domain, the ESRP protocol can scale to provide protection to large numbers of VLANs. All VLANs within an ESRP domain simultaneously share the same active and standby router and failover router, as long as one port of each member VLAN belongs to the domain master. Depending on the election policy used, when a port in a member VLAN belongs to the domain master, the member VLAN ports are considered when determining the ESRP master. You can configure a maximum of 64 ESRP domains in a network. If you disable an ESRP domain, the switch notifies its neighbor that the ESRP domain is going down, and the neighbor clears its neighbor table. If the master switch receives this information, it enters the neutral state to prevent a network loop. If the slave switch receives this information, it enters the neutral state.

460

ExtremeWare XOS 11.3 Concepts Guide

ESRP Concepts

ESRP Domain IDs


ESRP packets do not identify themselves to which domain they belong; you either configure a domain ID or the ESRP domain uses the 802.1Q tag (VLANid) of the master VLAN. A domain ID in the packet clearly classifies the packet, associates a received ESRP PDU to a specific ESRP domain, and tells the receiving port where the packet came from.

Linking ESRP Switches


When considering system design using ESRP, Extreme Networks recommends using a direct link. Direct links between ESRP switches are useful under the following conditions:

A direct link can provide a more direct routed path, if the ESRP switches are routing and supporting multiple VLANs where the master/slave configuration is split such that one switch is master for some VLANs and a second switch is master for other VLANs. The direct link can contain a unique router-to-router VLAN/subnet, so that the most direct routed path between two VLANs with different master switches uses a direct link, instead of forwarding traffic through another set of connected routers. A direct link can be used as a highly reliable method to exchange ESRP hello messages, so that the possibility of having multiple masters for the same VLAN is lessened if all downstream Layer 2 switches fail. A direct link is necessary for the ESRP host attach (HA) option. The direct link is used to provide Layer 2 forwarding services through an ESRP slave switch.

Direct links may contain a router-to-router VLAN, along with other VLANs participating in an ESRP domain. If multiple VLANs are used on the direct links, use 802.1Q tagging. The direct links may be aggregated into a load-shared group, if desired. If multiple ESRP domains share a host port, each VLAN must be in a different ESRP group.

ESRP and Hitless FailoverModular Switches Only


When you install two Management Switch Fabric Module (MSM) modules in a BlackDiamond chassis, one MSM assumes the role of primary and the other assumes the role of backup MSM. The primary MSM executes the switchs management functions, and the backup MSM acts in a standby role. Hitless failover transfers switch management control from the primary MSM to the backup MSM and maintains the state of ESRP. The ESRP extended version supports hitless failover. For hitless failover support, ESRP switches and the primary and backup MSMs must run a version of ExtremeWare XOS that supports hitless failover and operate in ESRP extended mode.

NOTE
Beginning with ExtremeWare XOS 11.0, the BlackDiamond 10K supports hitless failover for ESRP. If you are running an earlier version of ExtremeWare XOS, the BlackDiamond 10K switch does not support ESRP hitless failover. Beginning with ExtremeWare XOS 11.3, the BlackDiamond 8800 switch (formerly known as Aspen) supports hitless failover for ESRP. If you are running an earlier version of ExtremeWare XOS, the BlackDiamond 8800 does not support ESRP hitless failover.

The ESRP domain on the primary MSM is active and participates in the ESRP protocol. The ESRP domain on the backup MSM is in the neutral state listening for configuration changes, tracking failures,

ExtremeWare XOS 11.3 Concepts Guide

461

Extreme Standby Router Protocol and checkpointing messages and link state events. When you initiate MSM failover, the master ESRP switch notifies its neighbor ESRP switch about the failover. After the neighbor receives information from the master switch, the neighbor remains in its current state and waits for the failover to occur. After the failover from the primary MSM to the backup MSM is complete, the master ESRP switch notifies the neighbor so the neighbor can relinquish its current state. To initiate hitless MSM failover on a network that uses ESRP: 1 Confirm that the MSMs are synchronized and have identical software and switch configurations using the show switch {detail} command. The output displays the status of the MSMs, with the primary MSM showing MASTER and the backup MSM showing BACKUP (InSync). If the MSMs are not synchronized, proceed to step 2. If the MSMs are synchronized, proceed to step 3. 2 If the MSMs are not in sync, replicate all saved images and configurations from the primary to the backup using the synchronize command. 3 Initiate failover using the run msm-failover command. For more detailed information about verifying the status of the MSMs and system redundancy, see Understanding System Redundancy with Dual MSMs InstalledModular Switches Only on page 70. For more information about hitless failover, see Understanding Hitless Failover SupportModular Switches Only on page 74.

Determining the ESRP Master


The system determines the ESRP master switch (providing Layer 3 routing and/or Layer 2 switching services for a VLAN) using the following default factors:

StickinessThe switch with the higher sticky value has higher priority. When an ESRP domain claims master, its sticky value is set to 1 (available only in extended mode). Active portsThe switch that has the greatest number of active ports takes highest precedence. Tracking informationVarious types of tracking are used to determine if the switch performing the master ESRP function has connectivity to the outside world. ExtremeWare XOS supports the following types of tracking:

VLANTracks any active port connectivity to one designated VLANs. An ESRP domain can track one VLAN, and the tracked VLAN should not be a member of any other ESRP domain in the system. IP route table entryTracks specific learned routes from the IP route table. PingTracks ICMP ping connectivity to specified devices. Environment (health checks)Tracks the environment of the switch, including power supply and chassis temperature.

If any of the configured tracking mechanisms fail, the master ESRP switch relinquishes status as master, and remains in slave mode for as long as the tracking mechanism continues to fail.

ESRP priorityThis is a user-defined field. The range of the priority value is 0 to 255; a higher number has higher priority, except for 255. The default priority setting is 0. A priority setting of 255 makes an ESRP switch a standby switch that remains in slave mode until you change the priority setting. Extreme Networks recommends this setting for system maintenance. A switch with a priority setting of 255 will never become the master. System MAC addressThe switch with the higher MAC address has higher priority.

462

ExtremeWare XOS 11.3 Concepts Guide

Determining the ESRP Master

Active port weightThe switch that has the highest port weight takes precedence. The bandwidth of the port automatically determines the port weight (available only in extended mode).

You can configure the precedence order of the factors used by the system to determine the master ESRP switch. For more information about configuring the ESRP election metrics, see ESRP Election Algorithms on page 465.

Master Switch Behavior


If a switch is master, it actively provides Layer 3 routing services to other VLANs, and Layer 2 switching between all the ports of that VLAN. Additionally, the switch exchanges ESRP packets with other switches that are in slave mode.

Pre-Master Switch Behavior


A pre-master switch is ready to transition to master, but is going through possible loop detection prior to changing to the master state. Upon entering the pre-master state, the switch sends ESRP packets to other switches on that same VLAN. If the switch finds itself superior to its neighbor, and successfully executes loop detection techniques, the switch transitions to master. This temporary state avoids the possibility of having simultaneous masters.

Slave Switch Behavior


If a switch is in slave mode, it exchanges ESRP packets with other switches on that same VLAN. When a switch is in slave mode, it does not perform Layer 3 routing or Layer 2 switching services for the VLAN. From a Layer 3 routing protocol perspective (for example, RIP or OSPF), when in slave mode for the VLAN, the switch marks the router interface associated with that VLAN as down. From a Layer 2 switching perspective, no forwarding occurs between the member ports of the VLAN; this prevents loops and maintains redundancy. If you configure the switch to use the optional ESRP HA configuration, the switch continues Layer 2 forwarding to the master. For more information, see ESRP Host Attach on page 473.

Neutral Switch Behavior


The neutral state is the initial state entered into by the switch. In a neutral state, the switch waits for ESRP to initialize and run. A neutral switch does not participate in ESRP elections. If the switch leaves the neutral state, it enters the slave state.

Electing the Master Switch


A new master can be elected in one of the following ways:

A communicated parameter change Loss of communication between master and slave(s)

If a parameter determines the master changes (for example, link loss or priority change), the election of the new master typically occurs within one second. A parameter change triggers a handshake between the routers. As long as both routers agree upon the state transition, new master election is immediate.

ExtremeWare XOS 11.3 Concepts Guide

463

Extreme Standby Router Protocol If a switch in slave mode loses its connection with the master, a new election (using the same precedence order indicated on page 462 or using a configured precedence order described in ESRP Election Algorithms on page 465) occurs. The new election typically takes place in three times the defined timer cycle (8 seconds by default). Before the switch transitions to the master state, it enters a temporary pre-master state. While in the premaster state, the switch sends ESRP PDUs until the pre-master state timeout expires. Depending upon the election algorithm, the switch may then enter the master or slave state. Traffic is unaffected by the pre-master state because the master continues to operate normally. The pre-master state avoids the possibility of having simultaneous masters. You can configure the pre-master state timeout using the following command:
configure esrp <esrpDomain> timer premaster <seconds>

CAUTION
Configure the pre-master state timeout only with guidance from Extreme Networks personnel. Misconfiguration can severely degrade the performance of ESRP and your switch.

ESRP Failover Time


ESRP Failover time is largely determined by the following factors:

ESRP hello timer setting. ESRP neighbor timer setting. The routing protocol being used for interrouter connectivity if Layer 3 redundancy is used; OSPF failover time is faster than RIP failover time.

The failover time associated with the ESRP protocol depends on the timer setting and the nature of the failure. The default hello timer setting is 2 seconds; the range is 2 to 1024 seconds. The default neighbor timer setting is 8 seconds; the range is 3*hello to 1024 seconds. The failover time depends on the type of event that caused ESRP to failover. In most cases, a non-hardware failover is less than 1 second, and a hardware failover is 8 seconds. If routing is configured, the failover of the particular routing protocol (such as RIP V1, RIP V2, or OSPF) is added to the failover time associated with ESRP. If you use OSPF, make your OSPF configuration passive. A passive configuration acts as a stub area and helps increase the time it takes for recalculating the network. A passive configuration also maintains a stable OSPF core. For more information about the ESRP timers and configuring the ESRP timers, see the ExtremeWare XOS Command Reference Guide.

ESRP Election Algorithms


You configure the switch to use one of 16 different election algorithms to select the ESRP master. ESRP uses the default election policy for extended mode. If you have an ESRP domain operating in standard mode, the domain ignores the sticky and weight algorithms.

464

ExtremeWare XOS 11.3 Concepts Guide

Determining the ESRP Master To change the election algorithm, you must first disable the ESRP domain and then configure the new election algorithm. If you attempt to change the election algorithm without disabling the domain first, an error message appears. To disable the ESRP domain, use the following command:
disable esrp {<esrpDomain>}

To modify the election algorithm, use the following command:


configure esrp <esrpDomain> election-policy [ports > track > priority | ports > track > priority > mac | priority > mac | priority > ports > track > mac | priority > track > ports > mac | sticky > ports > track > priority | sticky > ports > track > priority > mac | sticky > ports > weight > track > priority > mac | sticky > priority > mac | sticky > priority > ports > track > mac | sticky > priority > track > ports > mac | sticky > track > ports > priority > | track > ports > priority | track > ports > priority > mac >]

Table 63 describes the ESRP election algorithms. Each algorithm considers the election factors in a different order of precedence. The election algorithms that use sticky and weight are only available in extended mode.

Table 63: ESRP election algorithms


Election Algorithm ports > track > priority ports > track > priority > mac Description Specifies that this ESRP domain should consider election factors in the following order: Active ports, tracking information, ESRP priority. Specifies that this ESRP domain should consider election factors in the following order: Active ports, tracking information, ESRP priority, MAC address. NOTE: This is the default election algorithm for standard mode. priority > mac priority > ports > track > mac Specifies that this ESRP domain should consider election factors in the following order: ESRP priority, MAC address. Specifies that this ESRP domain should consider election factors in the following order: ESRP priority, active ports, tracking information, MAC address. Specifies that this ESRP domain should consider election factors in the following order: ESRP priority, tracking information, active ports, MAC address. Specifies that this ESRP domain should consider election factors in the following order: Stickiness, active ports, tracking information, ESRP priority. Specifies that this ESRP domain should consider election factors in the following order: Stickiness, active ports, tracking information, ESRP priority, MAC address. Specifies that this ESRP domain should consider election factors in the following order: Stickiness, active ports, port weight, tracking information, ESRP priority, MAC address. NOTE: Beginning with ExtremeWare XOS 11.1 and later, this is the default election algorithm for extended mode. sticky > priority > ports > track > mac Specifies that this ESRP domain should consider election factors in the following order: Stickiness, ESRP priority, active ports, tracking information, MAC address.

priority > track > ports > mac

sticky > ports > track > priority

sticky > ports > track > priority > mac

sticky > ports > weight > track > priority > mac

ExtremeWare XOS 11.3 Concepts Guide

465

Extreme Standby Router Protocol

Table 63: ESRP election algorithms (Continued)


Election Algorithm sticky > priority > track > ports > mac Description Specifies that this ESRP domain should consider election factors in the following order: Stickiness, ESRP priority, tracking information, active ports, MAC address. Specifies that this ESRP domain should consider election factors in the following order: Stickiness, ESRP priority, MAC address. Specifies that this ESRP domain should consider election factors in the following order: Stickiness, tracking information, active ports, ESRP priority. Specifies that this ESRP domain should consider election factors in the following order: Tracking information, active ports, ESRP priority. Specifies that this ESRP domain should consider election factors in the following order: Tracking information, active ports, ESRP priority, MAC address.

sticky > priority > mac sticky > track > ports > priority

track > ports > priority track > ports > priority > mac

CAUTION
All switches in the ESRP network must use the same election algorithm, otherwise loss of connectivity, broadcast storms, or other unpredictable behavior may occur.

NOTE
If you have a network that contains a combination of switches running ExtremeWare XOS and ExtremeWare, only the ports-track-priority-mac election algorithm is compatible with ExtremeWare releases prior to version 6.0.

Configuring an ESRP Domain on a Switch


To create, configure, and enable a basic ESRP domain, complete the following steps: 1 Create and configure the master VLAN. 2 Create and configure the member VLAN(s), if applicable. 3 Create the ESRP domain. 4 Configure the ESRP domain ID, if applicable. 5 Add the master VLAN to the ESRP domain. 6 Add the member VLAN(s) to the ESRP domain, if applicable. 7 Enable ESRP for the specified ESRP domain. The instructions that follow assume that you have already created and configured the VLANs to use as the ESRP domain master and member VLANs. For more information about creating VLANs, see Chapter 5, Virtual LANs. For more information about ESRP master and member VLANs, see Adding VLANs to an ESRP Domain on page 468. You can also configure other ESRP domain parameters, including ESRP:

Mode of operation as described in Standard and Extended ESRP on page 459. Timers as described in the ExtremeWare XOS Command Reference Guide.

466

ExtremeWare XOS 11.3 Concepts Guide

Configuring an ESRP Domain on a Switch


Election algorithms as described in ESRP Election Algorithms on page 465. Tracking as described in ESRP Tracking on page 469. Port restart as described in ESRP Port Restart on page 473. Host attach as described in ESRP Host Attach on page 473. Groups as described in ESRP Groups on page 475.

For more detailed information about all of the commands used to create, configure, enable, and disable an ESRP domain, please refer to the ExtremeWare XOS Command Reference Guide.

Creating and Deleting an ESRP Domain


You specify a unique ESRP domain name to identify each ESRP domain in your network. To create an ESRP domain, use the following command:
create esrp <esrpDomain>

The esrpDomain parameter is a character string of up to 32 characters that identifies the ESRP domain to be created.

NOTE
If you use the same name across categories (for example, STPD and ESRP names) Extreme Networks recommends that you specify the appropriate keyword as well as the actual name. If you do not specify the keyword, the switch may display an error message.

The following example creates an ESRP domain named esrp1:


create esrp esrp1

To delete an ESRP domain, use the following command:


delete esrp <esrpDomain>

The following example deletes the ESRP domain named esrp1:


delete esrp esrp1

Configuring the ESRP Domain ID


If you choose not use the 802.1Q tag (VLANid) of the master VLAN, or you have an untagged master VLAN, you must create a domain ID before you can enable the ESRP domain. For more information about ESRP domains and the ESRP domain ID, see ESRP Domains on page 460. To configure an ESRP domain ID, use the following command:
configure esrp <esrpDomain> domain-id <number>

The number parameter specifies the number of the domain ID. The user-configured ID range is 4096 through 65,535. The following example creates a domain ID of 4097 for ESRP domain esrp1:

ExtremeWare XOS 11.3 Concepts Guide

467

Extreme Standby Router Protocol


configure esrp esrp1 domain-id 4097

Adding VLANs to an ESRP Domain


This section assumes that you have already created and configured the VLANs that you want to add to the ESRP domain.

Adding and Deleting a Master VLAN


The master VLAN is the VLAN on the ESRP domain that exchanges ESRP PDUs and data between a pair of ESRP-enabled devices. You must configure one master VLAN for each ESRP domain, and a master VLAN can belong to only one ESRP domain. To add a master VLAN to an ESRP domain, use the following command:
configure esrp <esrpDomain> add master <vlan_name>

The esrpDomain parameter specifies the name of the ESRP domain, and the vlan_name parameter specifies the name of the master VLAN. The following example adds the VLAN sales as the master VLAN to ESRP domain esrp1:
configure esrp esrp1 add master sales

To delete a master VLAN, you must first disable the ESRP domain before removing the master VLAN using the disable esrp {<esrpDomain>} command. To delete a master VLAN from an ESRP domain, use the following command:
configure esrp <esrpDomain> delete master <vlan_name>

The following examples removes the master VLAN sales from ESRP domain esrp1:
configure esrp esrp1 delete master sales

Adding and Deleting a Member VLAN


The member VLAN can belong to only one ESRP domain, and you configure zero or more member VLANs for each ESRP domain. The state of the ESRP device determines whether the member VLAN is in the forwarding or blocking state. To add a member VLAN to an ESRP domain, use the following command:
configure esrp <esrpDomain> add member <vlan_name>

The esrpDomain parameter specifies the name of the ESRP domain, and the vlan_name parameter specifies the name of the master VLAN. The following example adds the VLAN purple as a member VLAN to ESRP domain esrp1:
configure esrp esrp1 add member purple

To delete a member VLAN from an ESRP domain, use the following command:

468

ExtremeWare XOS 11.3 Concepts Guide

Advanced ESRP Features


configure esrp <esrpDomain> delete member <vlan_name>

The following example removes the member VLAN purple from ESRP domain esrp1:
configure esrp esrp1 delete member purple

Enabling and Disabling an ESRP Domain


To enable a specific ESRP domain, use the following command:
enable esrp <esrpDomain>

To disable a specific ESRP domain, use the following command:


disable esrp {<esrpDomain>}

Advanced ESRP Features


This section describes the following advanced ESRP features:

ESRP Tracking on page 469 ESRP Port Restart on page 473 ESRP Host Attach on page 473 ESRP Port Weight and Dont Count on page 474 ESRP Groups on page 475

ESRP Tracking
Tracking information is used to track various forms of connectivity from the ESRP switch to the outside world. This section describes the following ESRP tracking options:

ESRP Environment Tracking on page 470 ESRP VLAN Tracking on page 470 ESRP Route Table Tracking on page 470 ESRP Ping Tracking on page 471 Displaying Tracking Information on page 471

ESRP Environment Tracking


You can configure ESRP to track hardware status. If a power supply fails, if the chassis is overheating, or if a non-fully loaded power supply is detected, the priority for the ESRP domain will change to the failover settings. NOTE
ExtremeWare XOS determines the maximum available power required for the switch by calculating the number of power supplies and the power required by the installed modules. Enabling environmental tracking on the switch without enough power budget causes tracking to fail. In this case, the tracking failure occurs by design.

ExtremeWare XOS 11.3 Concepts Guide

469

Extreme Standby Router Protocol To configure the failover priority for an ESRP domain, follow these steps: 1 Set the failover priority, using the following command:
configure esrp <esrpDomain> add track-environment failover <priority>

2 Assign the priority flag precedence over the active ports count, using the following command:
configure esrp <esrpDomain> election-policy [ports > track > priority | ports > track > priority > mac | priority > mac | priority > ports > track > mac | priority > track > ports > mac | sticky > ports > track > priority | sticky > ports > track > priority > mac | sticky > ports > weight > track > priority > mac | sticky > priority > mac | sticky > priority > ports > track > mac | sticky > priority > track > ports > mac | sticky > track > ports > priority > | track > ports > priority | track > ports > priority > mac >]

Because the priority of both ESRP domains are set to the same value, ESRP will use the active ports count to determine the master ESRP domain.

ESRP VLAN Tracking


You can configure an ESRP domain to track port connectivity to a specified VLAN as criteria for ESRP failover. The number of VLAN active ports are tracked. If the switch is no longer connected to the specified VLAN, the switch automatically relinquishes master status and remains in slave mode. You can track a maximum of one VLAN. To add or delete the tracked VLAN, use one of the following commands:
configure esrp <esrpDomain> add track-vlan <vlan_name>> configure esrp <esrpDomain> delete track-vlan <vlan_name>

ESRP Route Table Tracking


You can configure ESRP to track specified routes in the route table as criteria for ESRP failover. If all of the configured routes are not available within the route table, the switch automatically relinquishes master status and remains in slave mode. You can track a maximum of eight routes per route table. To add or delete a tracked route, use one of the following commands:
configure esrp <esrpDomain> add track-iproute <ipaddress>/<masklength> configure esrp <esrpDomain> delete track-iproute <ipaddress>/<masklength>

ESRP Ping Tracking


You can configure ESRP to track connectivity using a simple ping to any device. This may represent the default route of the switch, or any device meaningful to network connectivity of the master ESRP switch. The switch automatically relinquishes master status and remains in slave mode if a ping keepalive fails. You can configure a maximum of eight ping tracks. NOTE
The ESRP ping tracking option cannot be configured to ping an IP address within an ESRP VLAN subnet. It should be configured on some other normal VLAN across the router boundary.

To configure ping tracking, use the following command:

470

ExtremeWare XOS 11.3 Concepts Guide

Advanced ESRP Features


configure esrp <esrpDomain> add track-ping <ipaddress> frequency <seconds> miss <misses>

To disable ping tracking, use the following command:


configure esrp <esrpDomain> delete track-ping <ipaddress>

Displaying Tracking Information


You can view the status of ESRP tracking on a per domain basis. The information displayed includes the type of tracking used by the ESRP domain and how you configured the tracking option. To view the status of tracked devices, use the following command:
show esrp <name>

ESRP Tracking Example


Figure 50 is an example of ESRP tracking.

Figure 50: ESRP tracking


ESRP master 200.1.1.1/24 vlan esrp1
Host 2: 200.1.1.14/24 Gateway: 200.1.1.1

(track-vlan) vlan vlan1


Router

L2 switch

10.10.10.121

Host 1: 200.1.1.13/24 Gateway: 200.1.1.1

ESRP slave 200.1.1.2/24


EX_094

To configure VLAN tracking, use the following command:


configure esrp esrp1 add track-vlan vlan1

Using the tracking mechanism, if VLAN1 fails, the ESRP master realizes that there is no path to the upstream router via the master switch and implements an ESRP failover to the slave switch. To configure route table tracking, use the following command:

ExtremeWare XOS 11.3 Concepts Guide

471

Extreme Standby Router Protocol


configure esrp esrp1 add track-iproute 10.10.10.0/24

The route specified in this command must exist in the IP routing table. When the route is no longer available, the switch implements an ESRP failover to the slave switch. To configure ping tracking, use the following command:
configure esrp esrp1 add track-ping 10.10.10.121 frequency 2 miss 2

The specified IP address is tracked. If the fail rate is exceeded, the switch implements an ESRP failover to the slave switch.

ESRP Port Restart


You can configure ESRP to restart ports in the ESRP master domain when the downstream switch is from a third-party vendor. This action takes down and restarts the port link to clear and refresh the downstream ARP table. To configure port restart, use the following command:
configure esrp <esrpDomain> ports <ports> restart

To disable port restart, use the following command:


configure esrp <esrpDomain> ports <ports> no-restart

If a switch becomes a slave, ESRP takes down (disconnects) the physical links of member ports that have port restart enabled. The disconnection of these ports causes downstream devices to remove the ports from their FDB tables. This feature allows you to use ESRP in networks that include equipment from other vendors. After 2 seconds, the ports re-establish connection with the ESRP switch. To remove a port from the restart configuration, delete the port from the VLAN and re-add it.

ESRP Host Attach


ESRP host attach (HA) is an optional ESRP configuration that allows you to connect active hosts directly to an ESRP master or slave switch. Normally, the Layer 2 redundancy and loop prevention capabilities of ESRP do not allow packet forwarding from the slave ESRP switch. ESRP HA allows configured ports that do not represent loops to the network to continue Layer 2 operation independent of their ESRP status. ESRP HA is designed for redundancy for dual-homed server connections. HA allows the network to continue Layer 2 forwarding regardless of the ESRP status. Do not use ESRP HA to interconnect devices on the slave ESRP switch instead of connecting directly to the ESRP master switch. The ESRP HA option is useful if you are using dual-homed network interface cards (NICs) for server farms, as shown in Figure 51. The ESRP HA option is also useful where an unblocked Layer 2 environment is necessary to allow high-availability security.

472

ExtremeWare XOS 11.3 Concepts Guide

Advanced ESRP Features

Figure 51: ESRP host attach


OSPF/BGP-4

EX_095

ESRP VLANs that share ESRP HA ports must be members of different ESRP groups. Each port can have a maximum of seven VLANs. If you use load sharing with the ESRP HA feature, configure the load-sharing group first and then enable HA on the group. Other applications allow lower-cost redundant routing configurations because hosts can be directly attached to the switch involved with ESRP. HA also requires at least one link between the master and the slave ESRP switch for carrying traffic and to exchange ESRP hello packets. ESRP domains that share ESRP HA ports must be members of different ESRP groups. NOTE
Do not use the ESRP HA feature with the following protocols: STP, Ethernet Automatic Protection Switching (EAPS), or VRRP. A broadcast storm may occur.

To configure a port to be a host port, use the following command:


configure esrp ports <ports> mode [host | normal]

ESRP Port Weight and Dont Count


In an ESRP domain, the switch automatically calculates the port weight based on the bandwidth of the port. ESRP uses the port weight to determine the master ESRP switch. For load-shared ports, configure the master port in the load-share group with the port weight. A loadshared port has an aggregate weight of all of its member ports. If you add or delete a load-shared port (or trunk), the master load-shared port weight is updated. If you do not want to count host ports and normal ports as active, configure the ESRP port weight on those ports. Their weight becomes 0 and that allows the port to be part of the VLAN, but if a link failure occurs, it will not trigger a reconvergence. With this configuration, ESRP experiences fewer state

ExtremeWare XOS 11.3 Concepts Guide

473

Extreme Standby Router Protocol changes due to frequent client activities like rebooting and unplugging laptops. This port is known as a dont-count port. To configure the port weight on either a host attach port or a normal port, use the following command:
configure esrp ports <ports> weight [auto | <port-weight>]

ESRP Groups
ExtremeWare XOS supports running multiple instances of ESRP within the same VLAN or broadcast domain. This functionality is called an ESRP group. Although other uses exist, the most typical application for multiple ESRP groups is when two or more sets of ESRP switches are providing fastfailover protection within a subnet. A maximum of seven distinct ESRP groups can be supported on a single ESRP switch, and a maximum of seven ESRP groups can be defined within the same network broadcast domain. You can configure a maximum of 32 ESRP groups in a network. For example, two ESRP switches provide Layer 2/Layer 3 connectivity and redundancy for the subnet, while another two ESRP switches provide Layer 2 connectivity and redundancy for a portion of the same subnet. Figure 52 shows ESRP groups.

Figure 52: ESRP groups

ESRP
Group1 Master

ESRP
Group1 Standby

ESRP
Group2 Master (L2 only)

ESRP Group2 Standby


(L2 only)

EX_096

An additional use for ESRP groups is ESRP HA, described on page 473.

474

ExtremeWare XOS 11.3 Concepts Guide

Displaying ESRP Information

Displaying ESRP Information


To view ESRP information, use the following command:
show esrp

Output from this command includes:


The operational state of an ESRP domain and the state of its neighbor ESRP port configurations

To view more detailed information about an ESRP domain, use the following command and specify the domain name:
show esrp {<name>}

Output from this command includes:


The operational state of an ESRP domain ESRP election policy ESRP tracking information Timer statistics State change information

To view ESRP counter information for a specific domain, use the following command:
show esrp {<name>} counters

To view ESRP-aware information for a specific domain (including the group number, MAC address for the master, and the age of information) use the following command:
show esrp {<name>}

For more information about any of the commands used to enable, disable, or configure ESRP, refer to the ExtremeWare XOS Command Reference Guide.

Using ELRP with ESRP


Extreme Loop Recovery Protocol (ELRP) is a feature of ExtremeWare XOS that allows you to prevent, detect, and recover from Layer 2 loops in the network. You can use ELRP with other protocols such as ESRP. With ELRP, each switch, except for the sender, treats the ELRP protocol data unit (PDU) as a Layer 2 multicast packet. The sender uses the source and destination MAC addresses to identify the packet it sends and receives. When the sender receives its original packet back, that triggers loop detection and prevention. Once a loop is detected, the loop recovery agent is notified of the event and takes the necessary actions to recover from the loop. ELRP operates only on the sending switch; therefore, ELRP operates transparently across the network. How a loop recovers is dependent upon the protocol that uses the loop detection services provided by ELRP. If you are using ELRP in an ESRP environment, ESRP may recover by transitioning the ESRP domain from master to slave. This section describes how ESRP uses ELRP to recover from a loop and the switch behavior.

ExtremeWare XOS 11.3 Concepts Guide

475

Extreme Standby Router Protocol

Using ELRP with ESRP to Recover Loops


ELRP sends loop-detect packets to notify ESRP about loops in the network. In an ESRP environment, when the current master goes down, one of the slaves becomes the master and continues to forward Layer 2 and Layer 3 traffic for the ESRP domain. If a situation occurs when a slave incorrectly concludes that the master is down, the slave incorrectly assumes the role of master. This introduces more than one master on the ESRP domain which causes temporary loops and disruption in the network.

ELRP on an ESRP Pre-Master Switch


A pre-master switch is an ESRP switch that is ready to transition to master but is going through possible loop detection. A pre-master periodically sends out ELRP loop-detect packets (ELRP PDUs) for a specified number of times and waits to make sure that none of the sent ELRP PDUs are received. Transition to master occurs only after this additional check is completed. If any of the ELRP PDUs are received, the switch transitions from pre-master to slave state. You configure pre-master ELRP loop detection on a per ESRP domain basis.

ELRP on an ESRP Master Switch


A master switch is an ESRP switch that sends ELRP PDUs on its ESRP domain ports. If the master switch receives an ELRP PDU that it sent, the master transitions to the slave. While in the slave state, the switch transitions to the pre-master rate and periodically checks for loops prior to transitioning to the master. The pre-master process is described in ELRP on an ESRP Pre-Master Switch on page 477. You configure the master ELRP loop detection on a per ESRP domain basis.

Configuring ELRP
This section describes the commands used to configure ELRP for use with ESRP. By default, ELRP is disabled.

Configuring Pre-Master Polling


If you enable the use of ELRP by ESRP in the pre-master state, ESRP requests ELRP packets sent to ensure that there is no loop in the network prior to changing to the master state. If no packets are received, there is no loop in the network. By default, the use of ELRP by ESRP in the pre-master state is disabled. To enable the use of ELRP by ESRP in the pre-master state on a per-ESRP domain basis, and to configure how often and how many ELRP PDUs are sent in the pre-master state, use the following command:
configure esrp <esrpDomain> elrp-premaster-poll enable {count <count> | interval <interval>}

Where the following is true:


esrpDomainSpecifies an ESRP domain name. countSpecifies the number of times the switch sends ELRP PDUs. The default is 3, and the range

is 1 to 32.

intervalSpecifies how often, in seconds, the ELRP PDUs are sent. The default is 1 seconds, and

the range is 1 to 32 seconds.

476

ExtremeWare XOS 11.3 Concepts Guide

Using ELRP with ESRP To disable the use of ELRP by ESRP in the pre-master state, use the following command:
configure esrp <esrpDomain> elrp-premaster-poll disable

Configuring Master Polling


If you enable the use of ELRP by ESRP in the master state, ESRP requests that ELRP packets are periodically sent to ensure that there is no loop in the network while ESRP is in the master state. By default, the use of ELRP by ESRP in the master state is disabled. To enable the use of ELRP by ESRP in the master state on a per-ESRP domain basis, and to configure how often the master checks for loops in the network, use the following command:
configure esrp <esrpDomain> elrp-master-poll enable {interval <interval>}

Where the following is true:


esrpDomainSpecifies an ESRP domain name. intervalSpecifies how often, in seconds, successive ELRP packets are sent. The default is 1

second, and the range is 1 to 64 seconds. To disable the use of ELRP by ESRP in the master state, use the following command:
configure esrp <esrpDomain> elrp-master-poll disable

Configuring Ports
You can configure one or more ports of an ESRP domain where ELRP packet transmission is requested by ESRP. This allows the ports in your network that might experience loops, such as ports that connect to the master, slave, or ESRP-aware switches, to receive ELRP packets. You do not need to send ELRP packets to host ports. By default, all ports of the ESRP domain have ELRP transmission enabled on the ports. If you change your network configuration, and a port no longer connects to a master, slave, or ESRPaware switch, you can disable ELRP transmission on that port. To disable ELRP transmission, use the following command:
configure esrp <esrpDomain> delete elrp-poll ports [<ports> | all]

To enable ELRP transmission on a port, use the following command:


configure esrp <esrpDomain> add elrp-poll ports [<ports> | all]

Displaying ELRP Information


To display summary ELRP information, use the following command:
show elrp

In addition to displaying the enabled/disabled state of ELRP, the command displays the total number of:

Clients registered with ELRP. ELRP packets transmitted.

ExtremeWare XOS 11.3 Concepts Guide

477

Extreme Standby Router Protocol

ELRP packets received.

For more information about the output associated with the show elrp command, see the ExtremeWare XOS Command Reference Guide.

ESRP Examples
This section provides examples of ESRP configurations.

Single Domain Using Layer 2 and Layer 3 Redundancy


The example shown in Figure 53 uses a number of Extreme Networks devices as edge switches that perform Layer 2 switching for ESRP domain esrp1 and VLAN Sales. The edge switches are dual-homed to the BlackDiamond 10K switches. The BlackDiamond 10K switches perform Layer 2 switching between the edge switches and Layer 3 routing to the outside world. Each edge switch is dual-homed using active ports to two BlackDiamond 10K switches. ESRP is enabled on each BlackDiamond 10K switch for the ESRP domain esrp1 that interconnects to the edge switches. Each BlackDiamond 10K switch has the VLAN Sales configured using the identical IP address. The BlackDiamond 10K switches then connect to the routed enterprise normally, using the desired routing protocol (for example, RIP or OSPF).

478

ExtremeWare XOS 11.3 Concepts Guide

ESRP Examples

Figure 53: Single ESRP domain using Layer 2 and Layer 3 redundancy

OSPF or RIP

Domain - esrp1, VLAN - Sales (master)

Domain - esrp1, VLAN - Sales (standby)

EX_097

The BlackDiamond 10K switch, acting as master for ESRP domain esrp1, performs both Layer 2 switching and Layer 3 routing services for VLAN Sales. The BlackDiamond 10K switch in slave mode for ESRP domain esrp1, performs neither for VLAN Sales, thus preventing bridging loops in the VLAN. The BlackDiamond 110K10808 switch. There are four paths between the BlackDiamond 10K switches on VLAN Sales. All the paths are used to send ESRP packets, allowing for four redundant paths for communication. The edge switches, being ESRP-aware, allow traffic within the VLAN to failover quickly because these edge switches sense when a master/slave transition occurs and flush FDB entries associated with the uplinks to the ESRP-enabled BlackDiamond 10K switches. The following commands are used to configure both BlackDiamond 10K switches. In this scenario, the master is determined by the programmed MAC address of the switch because the number of active links for the VLAN and the priority are identical to both switches. This example assumes the following:

ESRP election algorithm used is the default for standard mode (ports > track > priority > mac). The Inter-router backbone is running OSPF, with other routed VLANs already properly configured. Similar commands would be used to configure a switch on a network running RIP. Ports added to the VLAN have already been removed from VLAN default. IP address for the VLANs participating in ESRP must be identical.

ExtremeWare XOS 11.3 Concepts Guide

479

Extreme Standby Router Protocol

NOTE
If your network has switches running ExtremeWare and ExtremeWare XOS participating in ESRP, Extreme Networks recommends that the ExtremeWare XOS switches operate in ESRP standard mode. To change the mode of operation, use the configure esrp mode [extended | standard] command.

The commands used to configure the BlackDiamond 10K switches are as follows:
create vlan sales configure vlan sales add ports 1:1-1:4 configure vlan sales ipaddress 10.1.2.3/24 enable ipforwarding create esrp esrp1 configure esrp esrp1 domain-id 4096 configure esrp esrp1 add master sales enable esrp esrp1 configure ospf add vlan sales area 0.0.0.0 passive configure ospf routerid 5.5.5.5 enable ospf

480

ExtremeWare XOS 11.3 Concepts Guide

ESRP Examples

Multiple Domains Using Layer 2 and Layer 3 Redundancy


The example shown in Figure 54 illustrates an ESRP configuration that has multiple domains using Layer 2 and Layer 3 redundancy.

Figure 54: Multiple ESRP domains using Layer 2 and Layer 3 redundancy

Sales master, Engineering standby

OSPF or RIP

Sales standby, Engineering master

Sales

Sales

Sales + Engineering

Engineering

VLAN Sales, ESRP domain esrp1 - untagged link VLAN Engineering, ESRP domain esrp2 - untagged link VLANs Sales + Engineering, shared between ESRP domains esrp1 + esrp2 - tagged link

EX_098

This example builds on the previous example. It has the following features:

An additional VLAN, Engineering, is added that uses Layer 2 redundancy. The VLAN Sales uses three active links to each BlackDiamond 10K switch. The VLAN Engineering has two active links to each BlackDiamond 10K switch. One of the edge devices carries traffic for both VLANs. The link between the third edge device and the first BlackDiamond 10K switch uses 802.1Q tagging to carry traffic from both VLANs traffic on one link. The BlackDiamond switch counts the link active for each VLAN. The second BlackDiamond switch has a separate physical port for each VLAN connected to the third edge switch.

In this example, the BlackDiamond switches are configured for ESRP such that the VLAN Sales normally uses the first BlackDiamond switch and the VLAN Engineering normally uses the second BlackDiamond switch. This is accomplished by manipulating the ESRP priority setting for each VLAN for the particular BlackDiamond switch.

ExtremeWare XOS 11.3 Concepts Guide

481

Extreme Standby Router Protocol Configuration commands for the first BlackDiamond 10K switch are as follows:
create vlan sales configure vlan sales tag 10 configure vlan sales add ports 1:1-1:2 configure vlan sales add ports 1:3 tagged configure vlan sales ipaddress 10.1.2.3/24 create vlan engineering configure vlan engineering tag 20 configure vlan engineering add ports 1:4 configure vlan engineering add ports 1:3 tagged configure vlan engineering ipaddress 10.4.5.6/24 create esrp esrp1 configure esrp esrp1 domain-id 4096 configure esrp esrp1 add master sales configure esrp esrp1 priority 5 enable esrp esrp1 create esrp esrp2 configure esrp esrp2 domain-id 4097 configure esrp esrp2 add master engineering enable esrp esrp2

Configuration commands for the second BlackDiamond 10K switch are as follows:
create vlan sales configure vlan sales tag 10 configure vlan sales add ports 1:1-1:3 configure vlan sales ipaddress 10.1.2.3/24 create vlan engineering configure vlan engineering tag 20 configure vlan engineering add ports 1:4, 2:1 configure vlan engineering ipaddress 10.4.5.6/24 create esrp esrp1 configure esrp esrp1 domain-id 4096 configure esrp 1 add master sales enable esrp esrp1 create esrp esrp2 configure esrp esrp2 domain-id 4097 configure esrp esrp2 add master engineering configure esrp esrp2 priority 5 enable esrp esrp2

482

ExtremeWare XOS 11.3 Concepts Guide

ESRP Cautions

ESRP Cautions
This section describes important details to be aware of when configuring ESRP.

Configuring ESRP and IP Multinetting


When configuring ESRP and IP multinetting on the same switch, the same set of IP addresses must be configured for all involved VLANs.

ESRP and STP


A switch running ESRP should not simultaneously participate in STP for the same VLAN(s). Other switches in the VLAN being protected by ESRP may run STP; the switch running ESRP forwards, but does not filter, STP BPDUs. Therefore, you can combine ESRP and STP on a network and a VLAN, but you must do so on separate devices. You should be careful to maintain ESRP connectivity between ESRP master and slave switches when you design a network that uses ESRP and STP.

ESRP and VRRP


Do not configure ESRP and VRRP on the same VLAN or port. This configuration is not allowed or supported.

ESRP Groups and Host Attach


ESRP domains that share ESRP HA ports must be members of different ESRP groups.

Port Configurations and ESRP


The following ports cannot be part of a VLAN that participates in an ESRP domain:

A mirroring target port. A software-controlled redundant port. A Netlogin port.

In addition, the following ESRP ports cannot be a mirroring, software-controlled redundant port, or Netlogin port:

Host Attach port. Dont-count port (this port has a port weight of zero). Restart port.

ExtremeWare XOS 11.3 Concepts Guide

483

Extreme Standby Router Protocol

484

ExtremeWare XOS 11.3 Concepts Guide

22 Virtual Router Redundancy Protocol


This chapter covers the following topics:

Overview on page 485 Determining the VRRP Master on page 485 Additional VRRP Highlights on page 488 VRRP Operation on page 489 VRRP Configuration Parameters on page 491 VRRP Examples on page 492 VRRP Cautions on page 494

This chapter assumes that you are already familiar with the Virtual Router Redundancy Protocol (VRRP). If not, refer to the following publications for additional information:

RFC 2338Virtual Router Redundancy Protocol (VRRP) RFC 2787Definitions of Managed Objects for the Virtual Router Redundancy Protocol Draft IETF VRRP Specification v2.06

Overview
Like the Extreme Standby Router Protocol (ESRP), VRRP allows multiple switches to provide redundant routing services to users. VRRP is used to eliminate the single point of failure associated with manually configuring a default gateway address on each host in a network. Without using VRRP, if the configured default gateway fails, you must reconfigure each host on the network to use a different router as the default gateway. VRRP provides a redundant path for the hosts. Using VRRP, if the default gateway fails, the backup router assumes forwarding responsibilities.

Determining the VRRP Master


The VRRP master is determined by the following factors:

VRRP priorityThis is a user-defined field. The range of the priority value is 1 to 254; a higher number has higher priority. The value of 255 is reserved for a router that is configured with the virtual router IP address. A value of 0 is reserved for the master router, to indicate it is releasing responsibility for the virtual router. The default value is 100. Higher IP addressIf the routers have the same configured priority, the router with the higher IP address becomes the master.

ExtremeWare XOS 11.3 Concepts Guide

485

Virtual Router Redundancy Protocol

VRRP Tracking
Tracking information is used to track various forms of connectivity from the VRRP router to the outside world. ExtremeWare XOS supports the use of the following VRRP tracking options:

VRRP VLAN Tracking VRRP Route Table Tracking VRRP Ping Tracking

VRRP VLAN Tracking


You can configure VRRP to track connectivity of up to eight specified VLANs as criteria for failover. If no active ports remain on the specified VLANs, the router automatically relinquishes master status and remains in backup mode. To add or delete a tracked VLAN, use one of the following commands:
configure vrrp vlan <vlan_name> vrid <vridval> add track-vlan <target_vlan_name> configure vrrp vlan <vlan_name> vrid <vridval> delete track-vlan <target_vlan_name>

VRRP Route Table Tracking


You can configure VRRP to track specified routes in the route table as criteria for VRRP failover. If any of the configured routes are not available within the route table, the router automatically relinquishes master status and remains in INIT mode. To add or delete a tracked route, use one of the following commands:
configure vrrp vlan <vlan_name> vrid <vridval> add track-iproute <ipaddress>/ <masklength> configure vrrp vlan <vlan_name> vrid <vridval> delete track-iproute <ipaddress>/ <masklength>

VRRP Ping Tracking


You can configure VRRP to track connectivity using a simple ping to any outside responder. The responder may represent the default route of the router, or any device meaningful to network connectivity of the master VRRP router. If pinging the responder fails the specified number of times, consecutively, the router automatically re-assumes he master role, as soon as the connection is reestablished. To add or delete a tracked route, use one of the following commands:
configure vrrp vlan <vlan_name> vrid <vridval> add track-ping <ipaddress> frequency <seconds> miss <misses> configure vrrp vlan <vlan_name> vrid <vridval> delete track-ping <ipaddress>

To view the status of tracked devices, use the following command:


show vrrp {detail}

486

ExtremeWare XOS 11.3 Concepts Guide

Determining the VRRP Master

VRRP Tracking Example


Figure 55 is an example of VRRP tracking.

Figure 55: VRRP tracking


VRRP master 200.1.1.1/24 (track-vlan) vlan vlan1
Host 2: 200.1.1.14/24 Gateway: 200.1.1.1 L2 switch or hub Router

10.10.10.121

Host 1: 200.1.1.13/24 Gateway: 200.1.1.1

VRRP backup 200.1.1.2/24


EX_067

To configure VLAN tracking, as shown in Figure 55, use the following command:
configure vrrp vlan vrrp1 vrid 2 add track-vlan vlan1

Using the tracking mechanism, if VLAN1 fails, the VRRP master realizes that there is no path to upstream router via the master switch and implements a VRRP failover to the backup. To configure route table tracking, as shown in Figure 55, use the following command:
configure vrrp vlan vrrp1 vrid 2 add track-iproute 10.10.10.0/24

The route specified in this command must exist in the IP routing table. When the route is no longer available, the switch implements a VRRP failover to the backup. To configure ping tracking, as shown in Figure 55, use the following command:
configure vrrp vlan vrrp1 vrid 2 add track-ping 10.10.10.121 frequency 2 miss 2

The specified IP address is tracked. If the fail rate is exceeded, the switch implements a VRRP failover to the backup. A VRRP node with a priority of 255 may not recover from a ping-tracking failure if there is a Layer 2 switch between it and another VRRP node. In cases where a Layer 2 switch is used to connect VRRP nodes, Extreme Networks recommends that those nodes have priorities of less than 255.

ExtremeWare XOS 11.3 Concepts Guide

487

Virtual Router Redundancy Protocol

Electing the Master Router


VRRP uses an election algorithm to dynamically assign responsibility for the master router to one of the VRRP routers on the network. A VRRP router is elected master if the router has the highest priority (the range is 1 to 254; 255 is a reserved number). If the master router becomes unavailable, the election process provides dynamic failover and the backup router that has the highest priority assumes the role of master. A new master is elected when one of the following things happen:

VRRP is disabled on the master router. Loss of communication occurs between master and backup router(s). Another VRRP router is attached to the VLAN, and the new router has the same priority as the current master.

When VRRP is disabled on the master interface, the master router sends an advertisement with the priority set to 0 to all backup routers. This signals the backup routers that they do not need to wait for the master down interval to expire, and the master election process for a new master can begin immediately. The master down interval is set as follows: 3 * advertisement interval + skew time Where:

The advertisement interval is a user-configurable option. The skew time is (256-priority/256). NOTE

An extremely busy CPU can create a short dual master situation. To avoid this, increase the advertisement interval.

Additional VRRP Highlights


The following additional points pertain to VRRP:

VRRP packets are encapsulated IP packets. The VRRP multicast address is 224.0.0.18. The virtual router MAC address is 00 00 5E 00 01 <vrid> Duplicate VRIDs are allowed on the router but not on the same interface. The maximum number of supported VRIDs per interface is seven. An interconnect link between VRRP routers should not be used, except when VRRP routers have hosts directly attached. A maximum of 64 VRID instances are supported on the router. Up to seven unique VRIDs can be configured on the router. VRIDs can be re-used, but not on the same interface.

488

ExtremeWare XOS 11.3 Concepts Guide

VRRP Operation

VRRP and the Spanning Tree Protocol (STP) can be simultaneously enabled on the same switch. Extreme Networks does not recommend simultaneously enabling VRRP and ESRP on the same switch.

VRRP Operation
This section describes two VRRP network configurations:

A simple VRRP network A fully redundant VRRP network

Simple VRRP Network Configuration


Figure 56 shows a simple VRRP network.

Figure 56: Simple VRRP network


Switch A
Switch A = Master VRID = 1 Virtual router IP address = 192.168.1.3 MAC address = 00-00-5E-00-01-01 Priority = 255

Switch B
Switch B = Backup VRID = 1 Virtual router IP address = 192.168.1.3 MAC address = 00-00-5E-00-01-01 Priority = 100

192.168.1.3

192.168.1.5

Default Gateway = 192.168.1.3


EX_068

In Figure 56, a virtual router is configured on Switch A and Switch B using these parameters:

VRID is 1. MAC address is 00-00-5E-00-01-01. IP address is 192.168.1.3.

Switch A is configured with a priority of 255. This priority indicates that it is the master router. Switch B is configured with a priority of 100. This indicates that it is a backup router. The master router is responsible for forwarding packets sent to the virtual router. When the VRRP network becomes active, the master router broadcasts an ARP request that contains the virtual router MAC address (in this case, 00-00-5E-00-01-01) for each IP address associated with the virtual router. Hosts on the network use the virtual router MAC address when they send traffic to the default gateway. The virtual router IP address is configured to be the real interface address of the IP address owner. The IP address owner is usually the master router. The virtual router IP address is also configured on each backup router. However, in the case of the backup router, this IP address is not associated with a

ExtremeWare XOS 11.3 Concepts Guide

489

Virtual Router Redundancy Protocol physical interface. Each physical interface on each backup router must have a unique IP address. The virtual router IP address is also used as the default gateway address for each host on the network. If the master router fails, the backup router assumes forwarding responsibility for traffic addressed to the virtual router MAC address. However, because the IP address associated with the master router is not physically located on the backup router, the backup router cannot reply to TCP/IP messages (such as pings) sent to the virtual router.

Fully Redundant VRRP Network


You can use two or more VRRP-enabled switches to provide a fully redundant VRRP configuration on your network. Figure 57 shows a fully redundant VRRP configuration.

Figure 57: Fully redundant VRRP configuration


Switch A
Master for virtual IP 192.168.1.3 Master VRID = 1 Backup for virtual IP 192.168.1.5 Backup VRID = 2 MAC address = 00-00-5E-00-01-01

Switch B
Master for virtual IP 192.168.1.5 Master VRID = 2 Backup for virtual IP 192.168.1.3 Backup VRID = 1 MAC address = 00-00-5E-00-01-02

Default Route

Backup Route

EX_069

In Figure 57, switch A is configured as follows:


IP address 192.168.1.3 Master router for VRID 1 Backup router for VRID 2 MAC address 00-00-5E-00-01-01

Switch B is configured as follows:


IP address 192.168.1.5 Master router for VRID 2 Backup router for VRID 1 MAC address 00-00-5E-00-01-02

Both virtual routers are simultaneously operational. The traffic load from the four hosts is split between them. Host 1 and host 2 are configured to use VRID 1 on switch A as their default gateway. Host 3 and host 4 are configured to use VRID 2 on switch B as their default gateway. In the event that either switch fails, the backup router configured is standing by to resume normal operation.

490

ExtremeWare XOS 11.3 Concepts Guide

VRRP Configuration Parameters

VRRP Configuration Parameters


Table 64 lists the parameters that you configure on a VRRP router.

Table 64: VRRP configuration parameters


Parameter vrid priority Description This is the virtual router identifier and is a configured item in the range of 1- to 255. This parameter has no default value. This priority value to be used by this VRRP router in the master election process. A value of 255 is reserved for a router that is configured with the virtual router IP address. A value of 0 is reserved for the master router to indicate it is releasing responsibility for the virtual router. The range is 1 to 254. The default value is 100. This is the IP address associated with this virtual router. You can associate one or more IP addresses to a virtual router. This parameter has no default value. This is the time interval between advertisements, in seconds. The range is 1 to 255. The default value is 1 second. This is the time to skew master_down_interval, in seconds. This value is calculated as ((256-priority)/256). This is the time interval for the backup router to declare master down, in seconds. This value is calculated as ((3 * advertisement_interval) + skew_time). This controls whether a higher priority backup router preempts a lower priority master. A value of true allows preemption, and a value of false prohibits preemption. The default setting is true. NOTE: The router that owns the virtual router IP address always preempts, independent of the setting of this parameter.

ip_address

advertisement_interval skew_time master_down_interval

preempt_mode

ExtremeWare XOS 11.3 Concepts Guide

491

Virtual Router Redundancy Protocol

VRRP Examples
This section provides the configuration syntax for the two VRRP networks discussed in this chapter.

Configuring the Simple VRRP Network


Figure 58 shows the simple VRRP network described in Simple VRRP Network Configuration section.

Figure 58: Simple VRRP network


Switch A
Switch A = Master VRID = 1 Virtual router IP address = 192.168.1.3 MAC address = 00-00-5E-00-01-01 Priority = 255

Switch B
Switch B = Backup VRID = 1 Virtual router IP address = 192.168.1.3 MAC address = 00-00-5E-00-01-01 Priority = 100

192.168.1.3

192.168.1.5

Default Gateway = 192.168.1.3


EX_068

The following examples assume that you have already created the VLAN named vlan1 on the switch. The configuration commands for switch A are as follows:
configure vlan vlan1 ipaddress 192.168.1.3/24 create vrrp vlan vlan1 vrid 1 configure vrrp vlan vlan1 vrid 1 prioirty 255 configure vrrp vlan vlan1 vrid 1 add 192.168.1.3 enable vrrp

The configuration commands for switch B are as follows:


configure vlan vlan1 ipaddress 192.168.1.5/24 create vrrp vlan vlan1 vrid 1 configure vrrp vlan vlan1 vrid 1 add 192.168.1.3 enable vrrp

492

ExtremeWare XOS 11.3 Concepts Guide

VRRP Examples

Configuring the Fully Redundant VRRP Network


Figure 59 shows the fully redundant VRRP network configuration described in the Fully Redundant VRRP Network section.

Figure 59: Fully redundant VRRP configuration


Switch A
Master for virtual IP 192.168.1.3 Master VRID = 1 Backup for virtual IP 192.168.1.5 Backup VRID = 2 MAC address = 00-00-5E-00-01-01

Switch B
Master for virtual IP 192.168.1.5 Master VRID = 2 Backup for virtual IP 192.168.1.3 Backup VRID = 1 MAC address = 00-00-5E-00-01-02

Default Route

Backup Route

EX_069

The following examples assume that you have already created the VLAN named vlan1 on the switch. The configuration commands for switch A are as follows:
configure vlan vlan1 ipaddress create vrrp vlan vlan1 vrid 1 configure vrrp vlan vlan1 vrid configure vrrp vlan vlan1 vrid create vrrp vlan vlan1 vrid 2 configure vrrp vlan vlan1 vrid enable vrrp 192.168.1.3/24 1 priority 255 1 add 192.168.1.3 2 add 192.168.1.5

The configuration commands for switch B are as follows:


configure vlan vlan1 ipaddress create vrrp vlan vlan1 vrid 2 configure vrrp vlan vlan1 vrid configure vrrp vlan vlan1 vrid create vrrp vlan vlan1 vrid 1 configure vrrp vlan vlan1 vrid enable vrrp 192.168.1.5/24 2 priority 255 2 add 192.168.1.5 1 add 192.168.1.3

ExtremeWare XOS 11.3 Concepts Guide

493

Virtual Router Redundancy Protocol

VRRP Cautions
This section describes important details to be aware of when configuring VRRP.

Assigning Multiple Virtual IP Addresses


It is possible to assign multiple virtual IP addresses to the same VRID for a VRRP VR. In this case, you must meet the following conditions:

Multiple virtual IP addresses must be on the same subnet. The switch cannot own any of the multiple IP addresses.

For example, if you have a VLAN named v1 configured with IP addresses 1.1.1.1/24 and 2.2.2.2/24, the following configurations are allowed:

VRRP VR on VLAN v1 with VRID 99 with virtual IP addresses 1.1.1.2 and 1.1.1.3 VRRP VR on VLAN v1 with VRID 99 with virtual IP addresses 1.1.1.98 and 1.1.1.99

Using the VLAN v1 configuration described above, the following configurations are not allowed:

VRRP VR on VLAN v1 with VRID 99 with virtual IP addresses 1.1.1.1 and 2.2.2.2 (the IP addresses are not on the same subnet). VRRP VR on VLAN v1 with VRID 99 with virtual IP addresses 1.1.1.1 and 1.1.1.99 (the switch owns IP address 1.1.1.1).

VRRP and ESRP


Do not configure VRRP and ESRP on the same VLAN or port. This configuration is not allowed or supported.

494

ExtremeWare XOS 11.3 Concepts Guide

23 IPv4 Unicast Routing


This chapter describes the following IPv4 topics:

Overview of IPv4 Unicast Routing on page 495 Proxy ARP on page 499 Relative Route Priorities on page 498 Configuring IPv4 Unicast Routing on page 500 Verifying the IPv4 Unicast Routing Configuration on page 501 Routing Configuration Example on page 501 IPv4 Multinetting on page 503 Configuring DHCP/BOOTP Relay on page 509 UDP Forwarding on page 511

This chapter assumes that you are already familiar with IP unicast routing. If not, refer to the following publications for additional information:

RFC 1256ICMP Router Discovery Messages RFC 1812Requirements for IP Version 4 Routers NOTE

For more information on interior gateway protocols, see Chapter 25, RIP or Chapter 27, OSPF. For information on exterior gateway protocols, see Chapter 29, Border Gateway Protocol. For more information on switch support for IPv6, see Chapter 24, IPv6 Unicast Routing.

Overview of IPv4 Unicast Routing


The switch provides full Layer 3, IPv4 unicast routing. It exchanges routing information with other routers on the network using either the Routing Information Protocol (RIP) or the Open Shortest Path First (OSPF) protocol. The switch dynamically builds and maintains a routing table and determines the best path for each of its routes. Each host using the IP unicast routing functionality of the switch must have a unique IP address assigned. In addition, the default gateway assigned to the host must be the IP address of the router interface. Beginning in release 11.2, ExtremeWare XOS can provide both IPv4 and IPv6 routing at the same time. Separate routing tables are maintained for the two versions. Most commands that require you to specify an IP address can now accept either an IPv4 or IPv6 address and act accordingly. Additionally, many of the IP configuration, enabling, and display commands have added tokens for IPv4 and IPv6 to clarify the version required. For simplicity, existing commands affect IPv4 by default and require you to specify IPv6, so configurations from an earlier release will still correctly configure an IPv4 network.

ExtremeWare XOS 11.3 Concepts Guide

495

IPv4 Unicast Routing

Router Interfaces
The routing software and hardware routes IP traffic between router interfaces. A router interface is simply a virtual LAN (VLAN) that has an IP address assigned to it. As you create VLANs with IP addresses belonging to different IP subnets, you can also choose to route between the VLANs. Both the VLAN switching and IP routing function occur within the switch.

NOTE
Each IP address and mask assigned to a VLAN must represent a unique IP subnet. You cannot configure the same IP address and subnet on different VLANs.

In Figure 60, a BlackDiamond switch is depicted with two VLANs defined; Finance and Personnel. All ports on slots 1 and 3 are assigned to Finance; all ports on slots 2 and 4 are assigned to Personnel. Finance belongs to the IP network 192.207.35.0; the router interface for Finance is assigned the IP address 192.207.35.1. Personnel belongs to the IP network 192.207.36.0; its router interface is assigned IP address 192.207.36.1. Traffic within each VLAN is switched using the Ethernet MAC addresses. Traffic between the two VLANs is routed using the IP addresses.

Figure 60: Routing between VLANs

192.207.35.1 192.207.35.0 Finance

192.207.36.1 192.207.36.0 Personnel

192.207.35.11

192.207.35.13 192.207.36.14
EX_070

192.207.36.12

Populating the Routing Table


The switch maintains an IP routing table for both network routes and host routes. The table is populated from the following sources:

Dynamically, by way of routing protocol packets or by Internet Control Message Protocol (ICMP) redirects exchanged with other routers

496

ExtremeWare XOS 11.3 Concepts Guide

Overview of IPv4 Unicast Routing

Statically, by way of routes entered by the administrator:


Default routes, configured by the administrator Locally, by way of interface addresses assigned to the system By other static routes, as configured by the administrator NOTE

If you define a default route and subsequently delete the VLAN on the subnet associated with the default route, the invalid default route entry remains. You must manually delete the configured default route.

Dynamic Routes
Dynamic routes are typically learned by way of RIP or OSPF. Routers that use RIP or OSPF exchange information in their routing tables in the form of advertisements. Using dynamic routes, the routing table contains only networks that are reachable. Dynamic routes are aged out of the table when an update for the network is not received for a period of time, as determined by the routing protocol.

Static Routes
Static routes are manually entered into the routing table. Static routes are used to reach networks not advertised by routers. Static routes can also be used for security reasons, to control which routes you want advertised by the router. You configure, if you want all static routes to be advertised, using one of the following commands:

enable rip export [bgp | direct | e-bgp | i-bgp | ospf | ospf-extern1 | ospfextern2 | ospf-inter | ospf-intra | static] [cost <number> {tag <number>} | policy <policy-name>] or disable rip export [bgp | direct | e-bgp | i-bgp | ospf | ospf-extern1 | ospf-extern2 | ospf-inter | ospf-intra | static] enable ospf export [bgp | direct | e-bgp | i-bgp | rip | static] [cost <cost> type [ase-type-1 | ase-type-2] {tag <number>} | <policy-map>] or disable ospf export [bgp | direct | e-bgp | i-bgp | rip | static]

The default setting is disabled. Static routes are never aged out of the routing table. A static routes nexthop (gateway) must be associated with a valid IP subnet. An IP subnet is associated with a single VLAN by its IP address and subnet mask. If the VLAN is subsequently deleted, the static route entries using that subnet must be deleted manually.

Multiple Routes
When there are multiple, conflicting choices of a route to a particular destination, the router picks the route with the longest matching network mask. If these are still equal, the router picks the route using the following default criteria (in the order specified):

Directly attached network interfaces Static routes ICMP redirects

ExtremeWare XOS 11.3 Concepts Guide

497

IPv4 Unicast Routing


Dynamic routes Directly attached network interfaces that are not active. NOTE

If you define multiple default routes, the route that has the lowest metric is used. If multiple default routes have the same lowest metric, the system picks one of the routes.

You can also configure blackhole routestraffic to these destinations is silently dropped. The criteria for choosing from multiple routes with the longest matching network mask is set by choosing the relative route priorities.

Relative Route Priorities


Table 65 lists the relative priorities assigned to routes depending on the learned source of the route. NOTE
Although these priorities can be changed, do not attempt any manipulation unless you are expertly familiar with the possible consequences.

Table 65: Relative route priorities


Route Origin Direct BlackHole Static ICMP EBGP IBGP OSPFIntra OSPFInter RIP OSPFExtern1 OSPFExtern2 BOOTP Priority 10 50 1100 1200 1700 1900 2200 2300 2400 3200 3300 5000

To change the relative route priority, use the following command:


configure iproute {ipv4} priority [rip | blackhole | bootp | ebgp | ibgp | icmp | static | ospf-intra | ospf-inter | ospf-as-external | ospf-extern1 | ospf-extern2] <priority>

498

ExtremeWare XOS 11.3 Concepts Guide

Proxy ARP

IP Route Sharing
IP route sharing allows multiple equal-cost routes to be used concurrently. IP route sharing can be used with static routes or with OSPF routes. In OSPF, this capability is referred to as equal cost multipath (ECMP) routing. To use IP route sharing, use the following commands:
enable iproute sharing configure sharing address-based [L2 | L3]

Next, configure static routes and/or OSPF as you would normally. BlackDiamond 10K Only. For the BlackDiamond 10K, ExtremeWare XOS supports route sharing across up to 8 static routes and up to 8 ECMP routes for OSPF. BlackDiamond 8800 family and Summit X450. For the BlackDiamond 8800 family and the Summit X450 switches, ExtremeWare XOS supports route sharing across up to 4 static routes and up to 4 ECMP routes for OSPF. Using route sharing makes router troubleshooting more difficult because of the complexity in predicting the path over which the traffic will travel.

Proxy ARP
Proxy Address Resolution Protocol (ARP) was first invented so that ARP-capable devices could respond to ARP request packets on behalf of ARP-incapable devices. Proxy ARP can also be used to achieve router redundancy and to simplify IP client configuration. The switch supports proxy ARP for this type of network configuration. The section describes some example of using proxy ARP with the switch.

ARP-Incapable Devices
To configure the switch to respond to ARP requests on behalf of devices that are incapable of doing so, you must configure the IP address and MAC address of the ARP-incapable device using the use the following command:
configure iparp add proxy [<ipNetmask> | <ip_addr> {<mask>}] {vr <vr_name>} {<mac>} {always}

After it is configured, the system responds to ARP requests on behalf of the device as long as the following conditions are satisfied:

The valid IP ARP request is received on a router interface. The target IP address matches the IP address configured in the proxy ARP table. The proxy ARP table entry indicates that the system should answer this ARP request, based on the ingress VLAN and whether the always parameter is set. When the always option is set, the switch will ARP for the host even if the ARP requester is on the same subnet as the requested host. If the always option is not set, the switch will only answer if the ARP request comes in from a VLAN that is not on the same subnet as the requested host.

When all the proxy ARP conditions are met, the switch formulates an ARP response using the configured MAC address in the packet.

ExtremeWare XOS 11.3 Concepts Guide

499

IPv4 Unicast Routing

Proxy ARP Between Subnets


In some networks, it is desirable to configure the IP host with a wider subnet than the actual subnet mask of the segment. You can use proxy ARP so that the router answers ARP requests for devices outside of the subnet. As a result, the host communicates as if all devices are local. In reality, communication with devices outside of the subnet are proxied by the router. For example, an IP host is configured with a class B address of 100.101.102.103 and a mask of 255.255.0.0. The switch is configured with the IP address 100.101.102.1 and a mask of 255.255.255.0. The switch is also configured with a proxy ARP entry of IP address 100.101.0.0 and mask 255.255.0.0, without the always parameter. When the IP host tries to communicate with the host at address 100.101.45.67, the IP hosts communicates as if the two hosts are on the same subnet, and sends out an IP ARP request. The switch answers on behalf of the device at address 100.101.45.67, using its own MAC address. All subsequent data packets from 100.101.102.103 are sent to the switch, and the switch routes the packets to 100.101.45.67.

Configuring IPv4 Unicast Routing


This section describes the commands associated with configuring IP unicast routing on the switch. To configure routing: 1 Create and configure two or more VLANs. 2 Assign each VLAN that will be using routing an IP address using the following command:
configure vlan <vlan_name> ipaddress [<ipaddress> {<ipNetmask>} | ipv6-link-local | {eui64} <ipv6_address_mask>]

Ensure that each VLAN has a unique IP address. 3 Configure a default route using the following command:
configure iproute add default <gateway> {vr <vrname>} {<metric>} {multicast-only | unicast-only}

Default routes are used when the router has no other dynamic or static route to the requested destination. 4 Turn on IP routing for one or all VLANs using the following command:
enable ipforwarding {ipv4 | broadcast | ignore-broadcast | fast-direct-broadcast} {vlan <vlan_name>}

5 Configure the routing protocol, if required. For a simple network using RIP, the default configuration may be acceptable. 6 Turn on RIP or OSPF using one of the following commands:
enable rip enable ospf

500

ExtremeWare XOS 11.3 Concepts Guide

Verifying the IPv4 Unicast Routing Configuration

Verifying the IPv4 Unicast Routing Configuration


Use the show iproute command to display the current configuration of IP unicast routing for the switch and for each VLAN. The show iproute command displays the currently configured routes and includes how each route was learned. Additional verification commands include:

show iparpDisplays the IP ARP table of the system. show ipconfigDisplays configuration information for one or more VLANs.

Routing Configuration Example


Figure 61 illustrates a BlackDiamond switch that has three VLANs defined as follows:

Finance

All ports on slots 1 and 3 have been assigned. IP address 192.207.35.1. Protocol-sensitive VLAN using the IP protocol. All ports on slots 2 and 4 have been assigned. IP address 192.207.36.1. Port-based VLAN. All ports on slots 1 through 4 have been assigned.

Personnel

MyCompany

ExtremeWare XOS 11.3 Concepts Guide

501

IPv4 Unicast Routing

Figure 61: Unicast routing configuration example

192.207.35.1

192.207.36.1

MyCompany 192.207.35.0 Finance 192.207.36.0 Personnel

IP NetBIOS IP NetBIOS

IP NetBIOS IP NetBIOS

= IP traffic = NetBIOS traffic


EX_047

The stations connected to the system generate a combination of IP traffic and NetBIOS traffic. The IP traffic is filtered by the protocol-sensitive VLANs. All other traffic is directed to the VLAN MyCompany. In this configuration, all IP traffic from stations connected to slots 1 and 3 have access to the router by way of the VLAN Finance. Ports on slots 2 and 4 reach the router by way of the VLAN Personnel. All other traffic (NetBIOS) is part of the VLAN MyCompany. The example in Figure 61 is configured as follows:
create vlan Finance create vlan Personnel create vlan MyCompany configure Finance protocol ip configure Personnel protocol ip configure Finance add port 1:*,3:* configure Personnel add port 2:*,4:* configure MyCompany add port all configure configure configure configure Finance ipaddress 192.207.35.1 Personnel ipaddress 192.207.36.1 rip add vlan Finance rip add vlan Personnel

enable ipforwarding enable rip

502

ExtremeWare XOS 11.3 Concepts Guide

IPv4 Multinetting

IPv4 Multinetting
IP multinetting refers to having multiple IP networks on the same bridging domain (or VLAN). The hosts connected to the same physical segment can belong to any one of the networks, so multiple subnets can overlap onto the same physical segment. Any routing between the hosts in different networks is done through the interface of the router. Typically, different IP networks will be on different physical segments, but IP multinetting does not require this. Multinetting can be a critical element in a transition strategy, allowing a legacy assignment of IP addresses to coexist with newly configured hosts. However, because of the additional constraints introduced in troubleshooting and bandwidth, Extreme Networks recommends that you use multinetting as a transitional tactic only, and not as a long-term network design strategy. Multinetting was not supported in ExtremeWare XOS 10.1, but versions of ExtremeWare prior to that supported a multinetting implementation that required separate VLANs for each IP network. The implementation introduced in ExtremeWare XOS 11.0 is simpler to configure, does not require that you create a dummy multinetting protocol, and does not require that you create VLANs for each IP network. This implementation does not require you to explicitly enable IP multinetting. Multinetting is automatically enabled when a secondary IP address is assigned to a VLAN. The following sections discuss these multinetting topics:

Multinetting Topology on page 503 How Multinetting Affects Other Features on page 504 Configuring IPv4 Multinetting on page 508 IP Multinetting Examples on page 509

Multinetting Topology
For an IP multinetted interface, one of the IP networks on the interface acts as the transit network for the traffic that is routed by this interface. The transit network is the primary subnet for the interface. The remaining multinetted subnets, called the secondary subnets, must be stub networks. This restriction is required because it is not possible to associate the source of the incoming routed traffic to a particular network. IP routing happens between the different subnets of the same VLAN (one arm routing) and also between subnets of different VLANs.

ExtremeWare XOS 11.3 Concepts Guide

503

IPv4 Unicast Routing

Figure 62: Multinetted Network Topology


Transit network

VLAN multi Primary subnet

Secondary subnet-1 Secondary subnet-2

Host

BD10K
EX_102

Figure 62 shows a multinetted VLAN named multi. VLAN multi has three IP subnets so three IP addresses have been configured for the VLAN. One of the subnets is the primary subnet and can be connected to any transit network (for example, the Internet). The remaining two subnets are stub networks, and multiple hosts such as management stations (such as user PCs and file servers) can be connected to them. You should not put any additional routing or switching devices in the secondary subnets to avoid routing loops. In Figure 62 the subnets are on separate physical segments, however, multinetting can also support hosts from different IP subnets on the same physical segment. When multinetting is configured on a VLAN, the switch can be reached using any of the subnet addresses (primary or secondary) assigned to VLAN. This means that you can perform operations like ping, Telnet, Trivial File Transfer Protocol (TFTP), Secure Shell 2 (SSH2), and others to the switch from a host residing in either the primary or the secondary subnet of the VLAN. Other host functions (such as traceroute) are also supported on the secondary interface of a VLAN.

How Multinetting Affects Other Features


Multinetting will affect some other features in ExtremeWare XOS. The following sections explain how multinetting affects both Layer 2 and Layer 3 features.

ARP
ARP operates on the interface and responds to every request coming from either the primary or secondary subnet. When multiple subnets are configured on a VLAN and an ARP request is generated by the switch over that VLAN, the source IP address of the ARP request must be a local IP address of the subnet to which the destination IP address (which is being ARPed) belongs. For example, if a switch multinets the subnets 10.0.0.0/24 and 20.0.0.0/24 (with VLAN IP addresses of 10.0.0.1 and 20.0.0.1), and generates an ARP request for the IP address 10.0.0.2, then the source IP address in the ARP packet will be set to 10.0.0.1 and not to 20.0.0.1.

504

ExtremeWare XOS 11.3 Concepts Guide

IPv4 Multinetting

Route Manager
The Route Manager will install a route corresponding to each of the secondary interfaces. The route origin will be direct, will be treated as a regular IP route, and can be used for IP data traffic forwarding. These routes can also be redistributed into the various routing protocol domains if you configure route redistribution.

IRDP
There are some functional changes required in Internet Router Discovery Protocol (IRDP) as result of IP multinetting support. When IRDP is enabled on a Layer 3 VLAN, ExtremeWare XOS periodically sends ICMP router advertisement messages through each subnet (primary and secondary) and responds to ICMP router solicitation messages based on the source IP address of soliciting host.

Unicast Routing Protocols


Unicast routing protocols treat each IP network as an interface. The interface corresponding to the primary subnet is the active interface, and the interfaces corresponding to the secondary subnet are passive subnets. For example, in the case of Open Shortest Path First (OSPF), the system treats each network as an interface, and hello messages are not sent out or received over the non-primary interface. In this way, the router link state advertisement (LSA) includes information to advertise that the primary network is a transit network and the secondary networks are stub networks, thereby preventing any traffic from being routed from a source in the secondary network. Interface-based routing protocols (for example, OSPF) can be configured on per VLAN basis. There is no way to configure a routing protocol on an individual primary or secondary interface. Configuring a protocol parameter on a VLAN automatically configures the parameter on all its associated primary and secondary interfaces. The same logic applies to configuring IP forwarding, for example, on a VLAN. Routing protocols in the multinetted environment advertise the secondary subnets to their peers in their protocol exchange process. For example, for OSPF the secondary subnets are advertised as stub networks in router LSAs. RIP also advertises secondary subnets to its peers residing on the primary subnet. OSPF. This section describes the behavior of OSPF in an IPv4 multinetting environment:

Each network is treated as an interface, and hello messages are not sent out or received over the nonprimary interface. In this way, the router LSA includes information to advertise that the primary network is a transit network and the secondary networks are stub networks, thereby preventing any traffic from being routed from a source in the secondary network. Any inbound OSPF control packets from secondary interfaces are dropped. Direct routes corresponding to secondary interfaces can be exported into the OSPF domain (by enabling export of direct routes), if OSPF is not enabled on the container VLAN. When you create an OSPF area address range for aggregation, you must consider the secondary subnet addresses for any conflicts. That is, any secondary interface with the exact subnet address as the range cannot be in another area. The automatic selection algorithm for the OSPF router ID considers the secondary interface addresses also. The numerically highest interface address is selected as the OSPF router-id.

ExtremeWare XOS 11.3 Concepts Guide

505

IPv4 Unicast Routing RIP. This section describes the behavior of the Routing Information Protocol (RIP) in an IP multinetting environment:

RIP does not send any routing information update on the secondary interfaces. However, RIP will advertise networks corresponding to secondary interfaces in its routing information packet to the primary interface. Any inbound RIP control packets from secondary interfaces are dropped. Direct routes corresponding to secondary interfaces can be exported into the RIP domain (by enabling export of direct routes), if RIP is not enabled on the container VLAN.

BGP. There are no behavioral changes in the Border Gateway Protocol (BGP) in an IP multinetting environment. This section describes a set of recommendations for using BGP with IP multinetting:

Be careful of creating a BGP neighbor session with a BGP speaker residing in secondary subnet. This situation may lead to routing loops. All secondary subnets are like stub networks, so you must configure BGP in such a way that the BGP next hop becomes reachable using the primary subnet of a VLAN. When setting the BGP next hop using an inbound or outbound policy, ensure that the next hop is reachable from the primary interface. A BGP static network's reachability can also be resolved from the secondary subnet. Secondary interface addresses can be used as the source interface for a BGP neighbor. Direct routes corresponding to secondary interfaces can be exported into the BGP domain (by enabling export of direct routes).

IGMP Snooping and IGMP


Internet Group Management Protocol (IGMP) snooping and IGMP treat the VLAN as an interface. Only control packets with a source address belonging to the IP networks configured on that interface are accepted. IGMP accepts membership information that originates from hosts in both the primary and secondary subnets. The following describes the changes in behavior of IGMP in an IP multinetting environment:

A layer 3 VLAN will always use the primary IP address as the source address to send out an IGMP query, and querier election is based on the primary IP address of interface. Because the RFC dictates that there is only one querier per physical segment, the querier may be attached to any of configured IP interfaces, including secondary interfaces, although this is not a recommended configuration. For a static IGMP group, the membership report is also sent out using the primary IP address. For local multicast groups such as 224.0.0.X, the membership report is sent out using the first IP address configured on the interface, which is the primary IP address in ExtremeWare XOS. The source IP address check is disabled for any IGMP control packets (such as IGMP query and IGMP membership report). Source IP address checking for IGMP control packet id disabled for all VLANs, not just the multinetted VLANs.

Multicast Routing Protocols


For Protocol-Independent Multicast (PIM), the following behavior changes should be noted in a multinetting environment:

PIM does not peer with any other PIM router on a secondary subnet. PIM also processes data packets from the host on secondary subnets.

506

ExtremeWare XOS 11.3 Concepts Guide

IPv4 Multinetting

PIM also accepts membership information from hosts on secondary subnets.

EAPS, ESRP, and STP


Control protocols like Ethernet Automatic Protection Switching (EAPS), Extreme Standby Router Protocol (ESRP), and the Spanning Tree Protocol (STP) treat the VLAN as an interface. If the protocol control packets are exchanged as Layer 3 packets, then the source address in the packet is validated against the IP networks configured on that interface.

DHCP Server
The Dynamic Host Configuration Protocol (DHCP) server implementation in ExtremeWare XOS 11.0 will only support address allocation on the primary IP interface of the configured VLAN. That is, all DHCP clients residing on a bridging domain will have IP address belonging to the primary subnet. To add a host on secondary subnet, you must manually configure the IP address information on that host.

DHCP Relay
When the switch is configured as a DHCP relay agent, it will forward the DHCP request received from a client to the DHCP server. When doing so, the system sets the GIADDR field in the DHCP request packet to the primary IP address of the ingress VLAN. This means that the DHCP server that resides on a remote subnet will allocate an IP address for the client in the primary subnet range.

VRRP
The Virtual Router Redundancy Protocol (VRRP) protection can be provided for the primary as well as for the secondary IP addresses of a VLAN. For multinetting, the IP address assigned to an VRRP virtual router identifier (VRID) can be either the primary or the secondary IP addresses of the corresponding VLAN. For example, assume a VLAN v1 with two IP addresses: a primary IP address of 10.0.0.1/24, and a secondary IP address of 20.0.0.1/24.

ExtremeWare XOS 11.3 Concepts Guide

507

IPv4 Unicast Routing To provide VRRP protection to such a VLAN, you must configure one of the following:

Configure VRRP in VLAN v1 with two VRRP VRIDs. One VRID will have the virtual IP address 10.0.0.1/24, and the other VRID will have the virtual IP address 20.0.0.1/24. The other VRRP router, the one configured to act as backup, should be configured similarly. Configure VRRP in VLAN v1 with two VRRP VRIDs. One VRID will have the virtual IP address as 10.0.0.1/24, and the other VRID will have the virtual IP address as 20.0.0.1/24

OR

It is possible for a VRRP VR to have additional virtual IP addresses assigned to it. In this case, the following conditions must be met:

Multiple virtual IP addresses for the same VRID must be on the same subnet. Multiple virtual IP addresses must all not be owned by the switch.

Assuming a VLAN v1 that has IP addresses 1.1.1.1/24 and 2.2.2.2/24, here are some more examples of valid configurations:

VRRP VR on v1 with VRID of 99 with virtual IP addresses of 1.1.1.2 and 1.1.1.3 VRRP VR on v1 with VRID of 100 with virtual IP addresses of 2.2.2.3 and 2.2.2.4 VRRP VR on v1 with VRID of 99 with virtual IP addresses of 1.1.1.98 and 1.1.1.99 VRRP VR on v1 with VRID of 100 with virtual IP addresses of 2.2.2.98 and 2.2.2.99

Given the same VLAN v1 as above, here are some invalid configurations:

VRRP VR on v1 with VRID of 99 with virtual IP addresses of 1.1.1.1 and 2.2.2.2 (the virtual IP addresses are not on the same subnet) VRRP VR on v1 with VRID of 100 with virtual IP addresses of 2.2.2.2 and 1.1.1.1 (the virtual IP addresses are not on the same subnet) VRRP VR on v1 with VRID of 99 with virtual IP addresses of 1.1.1.1 and 1.1.1.99 (one virtual IP address is owned by the switch and one is not) VRRP VR on v1 with VRID of 100 with virtual IP addresses of 2.2.2.2 and 2.2.2.99 (one virtual IP address is owned by the switch and one is not).

Configuring IPv4 Multinetting


You configure IP multinetting by adding a secondary IP address to a vlan. Use the following command to add a secondary IP address:
configure vlan <vlan_name> add secondary-ipaddress [<ipaddress> {<netmask>} | <ipNetmask>]

Once you have added a secondary IP address, you cannot change the primary IP address of a VLAN until you first delete all the secondary IP addresses. Use the following command to delete secondary IP addresses:
configure vlan <vlan_name> delete secondary-ipaddress [<ipaddress> | all]

508

ExtremeWare XOS 11.3 Concepts Guide

Configuring DHCP/BOOTP Relay

IP Multinetting Examples
The following example configures a switch to have one multinetted segment (port 5:5) that contains three subnets (192.168.34.0/24, 192.168.35.0/24, and 192.168.37.0/24).
configure default delete port 5:5 create vlan multinet configure multinet ipaddress 192.168.34.1/24 configure multinet add secondary-ipaddress 192.168.35.1/24 configure multinet add secondary-ipaddress 192.168.37.1/24 configure multinet add port 5:5 enable ipforwarding

The following example configures a switch to have one multinetted segment (port 5:5) that contains three subnets (192.168.34.0, 192.168.35.0, and 192.168.37.0). It also configures a second multinetted segment consisting of two subnets (192.168.36.0 and 172.16.45.0). The second multinetted segment spans three ports (1:8, 2:9, and 3:10). RIP is enabled on both multinetted segments.
configure default delete port 5:5 create vlan multinet configure multinet ipaddress 192.168.34.1 configure multinet add secondary-ipaddress 192.168.35.1 configure multinet add secondary-ipaddress 192.168.37.1 configure multinet add port 5:5 configure default delete port 1:8, 2:9, 3:10 create vlan multinet_2 configure multinet_2 ipaddress 192.168.36.1 configure multinet_2 add secondary-ipaddress 172.16.45.1 configure multinet_2 add port 1:8, 2:9, 3:10 configure rip add vlan multinet configure rip add vlan multinet_2 enable rip enable ipforwarding

Configuring DHCP/BOOTP Relay


After IP unicast routing has been configured, you can configure the switch to forward Dynamic Host Configuration Protocol (DHCP) or BOOTP requests coming from clients on subnets being serviced by the switch and going to hosts on different subnets. This feature can be used in various applications, including DHCP services between Windows NT servers and clients running Windows 95. To configure the relay function: 1 Configure VLANs and IP unicast routing. 2 Enable the DHCP or BOOTP relay function, using the following command:
enable bootprelay {vr <vrid>}

3 Configure the addresses to which DHCP or BOOTP requests should be directed, using the following command:
configure bootprelay add <ip_address> {vr <vrid>}

To delete an entry, use the following command:


configure bootprelay delete [<ip_address> | all] {vr <vrid>}

ExtremeWare XOS 11.3 Concepts Guide

509

IPv4 Unicast Routing

Configuring the DHCP Relay Agent Option (Option 82)


After configuring and enabling the DHCP/BOOTP relay feature, you can enable the DHCP relay agent option feature. This feature inserts a piece of information, called option 82, into any DHCP request packet that is to be relayed by the switch. Similarly, if a DHCP reply received by the switch contains a valid relay agent option, the option will be stripped from the packet before it is relayed to the client. The DHCP relay agent option consists of two pieces of data, called sub-options. The first is the agent circuit ID sub-option, and the second is the agent remote ID sub-option. When the DHCP relay agent option is enabled on switches running ExtremeWare XOS, the value of these sub-options is set as follows:

Agent circuit ID sub-option: Contains the ID of the port on which the original DHCP request packet was received. This ID is encoded as ((slot_number * 1000) + port_number). For example, if the DHCP request were received on port 3:12, the agent circuit ID value would be 3012. On non-slot-based switches, the agent circuit ID value is simply the port number. Agent remote ID sub-option: Always contains the Ethernet MAC address of the relaying switch. You can display the Ethernet MAC address of the switch by issuing the show switch command.

To enable the DHCP relay agent option, use the following command after configuring the DHCP/ BOOTP relay function:
configure bootprelay dhcp-agent information option

To disable the DHCP relay agent option, use the following command:
unconfigure bootprelay dhcp-agent information option

In some instances, a DHCP server may not properly handle a DHCP request packet containing a relay agent option. To prevent DHCP reply packets with invalid or missing relay agent options from being forwarded to the client, use the following command:
configure bootprelay dhcp-agent information check

To disable checking of DHCP replies, use this command:


unconfigure bootprelay dhcp-agent information check

A DHCP relay agent may receive a client DHCP packet that has been forwarded from another relay agent. If this relayed packet already contains a relay agent option, then the switch will handle this packet according to the configured DHCP relay agent option policy. The possible actions are to replace the option information, to keep the information, or to drop packets containing option 82 information. To configure this policy, use the following command:
configure bootprelay dhcp-agent information policy [drop | keep | replace]

The default relay policy is replace. To configure the policy to the default, use this command:
unconfigure bootprelay dhcp-agent information policy

For more general information about the DHCP relay agent information option, refer to RFC 3046.

Verifying the DHCP/BOOTP Relay Configuration


To verify the DHCP/BOOTP relay configuration, use the following command:
show bootprelay

510

ExtremeWare XOS 11.3 Concepts Guide

UDP Forwarding This command displays the configuration of the BOOTP relay service and the addresses that are currently configured.

UDP Forwarding
UDP Forwarding is a flexible and generalized routing utility for handling the directed forwarding of broadcast UDP packets. UDP forwarding enables you to configure your switch so that inbound broadcast UDP packets on a VLAN are forwarded to a particular destination IP address or VLAN. UDP Forwarding allows applications, such as multiple DHCP relay services from differing sets of VLANs, to be directed to different DHCP servers. The following rules apply to UDP broadcast packets handled by this feature:

If the UDP profile includes BOOTP or DHCP, it is handled according to guidelines specified in RFC 1542. If the UDP profile includes other types of traffic, these packets have the IP destination address modified as configured, and changes are made to the IP and UDP checksums and decrements to the TTL field, as appropriate.

If UDP Forwarding is used for BOOTP or DHCP forwarding purposes, do not configure or use the existing bootprelay function. However, if the previous bootprelay functions are adequate, you may continue to use them. NOTE
UDP forwarding only works across a layer 3 boundary and currently, UDP forwarding can be applied to IPv4 packets only, not to IPv6 packets.

Configuring UDP Forwarding


To configure UDP Forwarding, create an policy file for your UDP profile, and then associate the profile with a VLAN using the following command:
configure vlan <vlan_name> udp-profile [<profilename> | none]

You can apply a UDP forwarding policy only to an L3 VLAN (a Vlan having at least one IP address configured on it). If there is no IP address configured on the VLAN, then the command will be rejected. UDP profiles are similar to ACL policy files. UDP profiles use a subset of the match conditions allowed for ACLs. A UDP forwarding policy must contain only the following attributes. Unrecognized attributes will be ignored.

Match attributes

Destination UDP Port Number (destination-port) Source IP address (source-ipaddress) Destination IP address (destination-ipaddress) VLAN name (vlan)

Action modified (set) attributes


Policy files used for UDP forwarding are processed differently from standard policy files. Instead of terminating when an entrys match clause becomes true, each entry in the policy file will be processed and the corresponding action will be taken for each true match clause.

ExtremeWare XOS 11.3 Concepts Guide

511

IPv4 Unicast Routing For example, if the following policy file is used as a UDP forwarding profile, any packets destined for UDP port 67 will be sent to IP address 20.0.0.5 AND flooded to VLAN to7:
entry one { if match all { destination-port 67 ; } then { destination-ipaddress 20.0.0.5 ; } } entry two { if match all { destination-port 67 ; } then { vlan "to7" ; } }

If you include more than one VLAN set attribute or more than one destination-ipaddress set attribute in one policy entry, the last one will be accepted and the rest ignored. Therefore, you can have two valid set statements in each entry of a UDP forwarding policy; one a destination-ipaddress and one a VLAN. ExtremeWare XOS currently allows a maximum of eight entries in a UDP forwarding policy, so you can define a maximum of sixteen destinations for one inbound broadcast UDP packet: eight IP address and eight VLANs.

NOTE
It is strongly advised not to have more than eight entries in a UDP forwarding profile. The UDP forwarding module will process those entries even if the entries do not contain any attributes for UDP forwarding. Having more than eight entries will drastically reduce the performance of the system. If the inbound UDP traffic rate is very high, having more than eight entries could cause the system to freeze or become locked.

NOTE
If you rename a VLAN referred to in your UDP forwarding profile, you must manually edit the policy to reflect the new name, and refresh the policy.

You can also validate whether the UDP profile has been successfully associated with the VLAN by using the command show policy {<policy-name> | detail}. UDP forwarding is implemented as part of the netTools process, so the command will display netTools as a user of the policy. To remove a policy, use the none form of the following command:
configure vlan <vlan_name> udp-profile [<profilename> | none]

or use this command:


unconfigure vlan <vlan_name> udp-profile

For more information about creating and editing policy files, see Chapter 12, Policy Manager. For more information about ACL policy files, see Chapter 13, Access Lists (ACLs).

512

ExtremeWare XOS 11.3 Concepts Guide

UDP Forwarding

UDP Echo Server


You can use UDP echo packets to measure the transit time for data between the transmitting and receiving end. To enable UDP echo server support, use the following command:
enable udp-echo-server {vr <vrid>}{udp-port <port>}

To disable UDP echo server support, use the following command:


disable udp-echo-server {vr <vrid>}

ExtremeWare XOS 11.3 Concepts Guide

513

IPv4 Unicast Routing

514

ExtremeWare XOS 11.3 Concepts Guide

24 IPv6 Unicast Routing


This chapter covers the following topics: This chapter describes the following topics:

Overview of IPv6 Unicast Routing on page 515 Router Interfaces on page 516 Specifying IPv6 Addresses on page 516 Neighbor Discovery Protocol on page 518 Populating the Routing Table on page 519 Configuring IP Unicast Routing on page 522 Verifying the IP Unicast Routing Configuration on page 522 Routing Configuration Example on page 522

This chapter assumes that you are already familiar with IPv6 unicast routing. If not, refer to the following publications for additional information:

RFC 2460Internet Protocol, Version 6 (IPv6) Specification RFC 3513Internet Protocol Version 6 (IPv6) Addressing Architecture NOTE

For more information on interior gateway protocols, see Chapter 26, RIPng or Chapter 28, OSPFv3.

Overview of IPv6 Unicast Routing


The switch provides full Layer 3, IPv6 unicast routing. It exchanges routing information with other routers on the network using either the IPv6 version of Routing Information Protocol (RIPng) or the IPv6 version of Open Shortest Path First (OSPFv3) protocol. The switch dynamically builds and maintains a routing table and determines the best path for each of its routes. Beginning in release 11.2, ExtremeWare XOS can provide both IPv4 and IPv6 routing at the same time. Separate routing tables are maintained for the two protocols. Most commands that require you to specify an IP address can now accept either an IPv4 or IPv6 address and act accordingly. Additionally, many of the IP configuration, enabling, and display commands have added tokens for IPv4 and IPv6 to clarify the version required. For simplicity, existing commands affect IPv4 by default and require you to specify IPv6, so configurations from an earlier release will still correctly configure an IPv4 network. ACLs and routing policies also support IPv6. Use an IPv6 address in a rule entry will automatically use IPv6.

NOTE
IPv6 functionality is supported only on the virtual routers VR-Default and VR-Mgmt. VR-Mgmt supports only IPv6 addressing and static routing; VR-Default also supports dynamic routing.

ExtremeWare XOS 11.3 Concepts Guide

515

IPv6 Unicast Routing

Router Interfaces
The routing software and hardware routes IPv6 traffic between router interfaces. A router interface is either a virtual LAN (VLAN) that has an IP address assigned to it, or, new for IPv6, a layer 3 tunnel. As you create VLANs and tunnels with IPv6 addresses, you can also choose to route (forward traffic) between them. Both the VLAN switching and IP routing function occur within the switch. An interface can have up to 255 IPv6 addresses, with at least one being a link local address. IPv4 and IPv6 interfaces can coexist on the same VLAN, allowing both IPv4 and IPv6 networks to coexist on the same Layer 2 broadcast domain.

NOTE
Each IP address and mask assigned to a VLAN must represent a unique IP subnet. You cannot configure the same IP address and subnet on different VLANs within the same virtual router.

Tunnels
Layer 3 tunnels are a transition method, as networks change over from IPv4 to IPv6. ExtremeWare XOS supports the use of IPv6-in-IPv4 tunnels (known as configured tunnels or 6in4 tunnels) and IPv6-toIPv4 tunnels (known as 6to4 tunnels). To create or delete a tunnel, use the following commands:
create tunnel <tunnel_name> 6to4 source <source-address> create tunnel <tunnel_name> ipv6-in-ipv4 destination <destination-address> source <source-address> delete tunnel <tunnel_name>

To configure and unconfigure IPv6 addresses for the tunnels, use the following commands:
configure tunnel <tunnel_name> ipaddress [{eui64} [<ipv6_address_mask> | <ipv6_address>] | ipv6-link-local] unconfigure tunnel <tunnel_name> ipaddress <ipv6_address_mask>

To display tunnel information, use the following commands:


show tunnel show ipstats ipv6 {vlan <name> | tunnel <tunnelname> | vr <vrname>} show ipconfig ipv6 {vlan <vlan_name> | tunnel <tunnelname>}

Specifying IPv6 Addresses


IP addresses have gone from the 32-bit (four-byte) numbers of IPv4 to the 128-bit (16-byte) numbers of IPv6. The ExtremeWare XOS CLI accepts two standard representations for IPv6 addresses, as described in RFC 3513, section 2.2, items 1, 2, and 3. For example, the 128 bits of the address are represented by eight, four-digit hexadecimal numbers separated by colons:
2000:af13:ee10:34c5:800:9192:ba89:2311 3f11:5655:2300:304:0000:0000:7899:acde

516

ExtremeWare XOS 11.3 Concepts Guide

Overview of IPv6 Unicast Routing Leading zeros in a four-digit group can be omitted. There is a special use of a double colon (::) in an address. The double colon stands for one or more groups of 16 bits of zeros and can only be used once in an address. For example, the following addresses:
fe80:0:0:0:af34:2345:4afe:0 fe80:0:0:111:0:0:0:fe11 3c12:0:0:0:0:89:ff:3415

can be represented as:


fe80::af34:2345:4afe:0 fe80:0:0:111::fe11 3c12::89:ff:3415

Additionally, you can specify an address in a mixed IPv4/IPv6 mode that uses six, four-digit hexadecimal numbers for the highest-order part of the address, and uses the IPv4 dotted decimal representation for the lowest-order remaining portion. For example:
0:0:0:0:0:0:192.168.1.1 0:0:0:0:0:ffff:10.0.14.254

These can be represented as:


::192.168.1.1 ::ffff:10.0.14.254

Duplicate Address Detection


When you configure an active interface with an IPv6 address, the interface must send out an advertisement containing its address. All other interfaces on the subnet have the opportunity to respond to the newly configured interface, and inform it that the address is a duplicate. Only after this process occurs, can the interface use the newly configured address. If the interface receives a message that the newly configured address is a duplicate, it cannot use the address. Until the Duplicate Address Detection (DAD) process completes, the new address is considered tentative, and will be shown as such in any display output. If the address is a duplicate, it will also be labeled as such, and must be reconfigured. On an active interface, the DAD process should occur so quickly that you would not see the address labeled as tentative. However, if you are configuring an interface before enabling it, and you display the configuration, you will see that the address is currently tentative. As soon as you enable the interface, the address should be ready to use, or labeled as duplicate and must be reconfigured. See RFC 2462, IPv6 Stateless Address Autoconfiguration, for more details.

Scoped Addresses
IPv6 uses a category of addresses called link local addresses that are used solely on a local subnet. Due to the way that local link addresses can be automatically assigned, a switch can have the same link local address assigned to different VLANs, or different neighbors on different links may be using the same link local address. Because of this, there are cases where you need to specify an address and a VLAN/ tunnel to indicate which interface to use. For those cases, you can indicate the interface by using a scoped address. To scope the address, append the VLAN/tunnel name to the end of the address, separated by a percent sign (%). For example, to indicate the link local address fe80::2 on VLAN finance, use the following form:
fe80::14%finance

ExtremeWare XOS 11.3 Concepts Guide

517

IPv6 Unicast Routing Scoped addresses also appear in the outputs of display commands.

IPv6 Addresses Used in Examples


For the purposes of documentation, we follow RFC 3849, which indicates that the prefix 2001:db8::/32 can be used as a global unicast address prefix and will not be assigned to any end party.

Neighbor Discovery Protocol


The Neighbor Discovery Protocol, as defined in RFC 2461, defines mechanisms for the following functions:

Resolving link-layer addresses of the IPv6 nodes residing on the link. Locating routers residing on the attached link. Locating the address prefixes that are located on the attached link. Learn link parameters such as the link MTU, or Internet parameters such as the hop limit value that has to be used in the outgoing packets. Automatic configuration of the IPv6 address for an interface. Detect whether the address that it wishes to use is not already in use by another node, also known as Duplicate Address Detection (DAD). Redirect the traffic to reach a particular destination through a better first-hop.

MAC Address Resolution


In IPv4, MAC address resolution is done by ARP. For IPv6, this functionality is handled by the Neighbor Discovery Protocol. The router maintains a cache of IPv6 addresses and their corresponding MAC addresses and allows the system to respond to requests from other nodes for the MAC address of the IPv6 Addresses configured on the interfaces. You can also statically configure the MAC Address of IPv6 destinations on the attached links. Use the following commands to configure, display, and clear the dynamic Neighbor Discovery cache:
configure neighbor-discovery cache {vr <vr_name>} add [<ipv6address> | <scoped_link_local>] <mac> configure neighbor-discovery cache delete {vr <vr_name>} [<ipv6address> | <scoped_link_local>] show neighbor-discovery cache ipv6 {[<ipv6_addr> | <mac> | permanent] {vr <vr_name>} | vlan <vlan_name> | vr <vr_name>} clear neighbor-discovery cache ipv6 {<ipv6address> {vr <vr_name>} | vlan <vlan_name> | vr <vr_name>}

Router Discovery
Also supported is router discoverythe ability to send out router advertisements that can be used by a host to discover the router. The advertisements sent out contain the prefixes and configuration parameters that allow the end nodes to auto-configure their addresses. The switch also responds to requests from nodes for router advertisements.

518

ExtremeWare XOS 11.3 Concepts Guide

Overview of IPv6 Unicast Routing The following settings can be configured on an interface to manage router advertisements:

Settings to control the sending of router advertisements over the interface periodically and to control responding to router solicitations. The maximum time between sending unsolicited router advertisements The minimum time between sending unsolicited router advertisements Managed Address Configuration Flag Other Stateful Configuration Flag Link MTU Retransmit Timer Current Hop Limit Default Lifetime Reachable Time

You can configure the following values, that are advertised by the switch:

Additionally, you can configure the following values for each prefix on the prefix list associated with an interface:

Valid Lifetime of the Prefix On-Link Flag Preferred Lifetime of the Prefix Autonomous Flag

To enable router discovery on a VLAN, use the following command:


enable router-discovery {ipv6} {vlan <vlan_name>}

To configure the prefixes advertised by router discovery, use the following command to add prefixes:
configure vlan <vlan_name> router-discovery {ipv6} add prefix <prefix>

To display router discover settings, use the following command:


show router-discovery {ipv6} {vlan <vlan_name>}

NOTE
Unlike ExtremeWare, ExtremeWare XOS does not support host processing of neighbor router advertisements.

Populating the Routing Table


The switch maintains an IP routing table for both network routes and host routes. The table is populated from the following sources:

Dynamically, by way of routing protocol packets or by Internet Control Message Protocol (ICMP) redirects exchanged with other routers Statically, by way of routes entered by the administrator:

Default routes, configured by the administrator Locally, by way of interface addresses assigned to the system By other static routes, as configured by the administrator

ExtremeWare XOS 11.3 Concepts Guide

519

IPv6 Unicast Routing

NOTE
If you define a default route and subsequently delete the VLAN on the subnet associated with the default route, the invalid default route entry remains. You must manually delete the configured default route.

Dynamic Routes
Dynamic routes are typically learned by way of RIPng or OSPFv3. Routers that use RIPng or OSPFv3 exchange information in their routing tables in the form of advertisements. Using dynamic routes, the routing table contains only networks that are reachable. Dynamic routes are aged out of the table when an update for the network is not received for a period of time, as determined by the routing protocol.

Static Routes
Static routes are manually entered into the routing table. Static routes are used to reach networks not advertised by routers. Static routes can also be used for security reasons, to control which routes you want advertised by the router. You configure, if you want all static routes to be advertised, using one of the following commands:

enable ripng export [direct | ospfv3 | ospfv3-extern1 | ospfv3-extern2 | ospfv3inter | ospfv3-intra | static] [cost <number> {tag <number>} | policy <policyname>] or disable ripng export [direct | ospfv3 | ospfv3-extern1 | ospfv3-extern2 | ospfv3-inter | ospfv3-intra | static] enable ospfv3 {domain <domainName>} export [direct | ripng | static] [cost <cost> type [ase-type-1 | ase-type-2] {tag <number>} | <policy-map>] or disable ospfv3 {domain <domainName>} export [direct | ripng | static]

The default setting is disabled. Static routes are never aged out of the routing table. A static routes nexthop (gateway) must be associated with a valid IP subnet. An IP subnet is associated with a single VLAN by its IP address and subnet mask. If the VLAN is subsequently deleted, the static route entries using that subnet must be deleted manually.

Multiple Routes
When there are multiple, conflicting choices of a route to a particular destination, the router picks the route with the longest matching network mask. If these are still equal, the router picks the route using the following default criteria (in the order specified):

Directly attached network interfaces Static routes ICMP redirects Dynamic routes Directly attached network interfaces that are not active.

520

ExtremeWare XOS 11.3 Concepts Guide

Overview of IPv6 Unicast Routing

NOTE
If you define multiple default routes, the route that has the lowest metric is used. If multiple default routes have the same lowest metric, the system picks one of the routes.

You can also configure blackhole routestraffic to these destinations is silently dropped. The criteria for choosing from multiple routes with the longest matching network mask is set by choosing the relative route priorities.

Relative Route Priorities


Table 66 lists the relative priorities assigned to routes depending on the learned source of the route. NOTE
Although these priorities can be changed, do not attempt any manipulation unless you are expertly familiar with the possible consequences.

Table 66: Relative route priorities


Route Origin Direct BlackHole Static ICMP OSPF3Intra OSPF3Inter RIPng OSPFv3 ASExt OSPFv3 Extern1 OSPFv3 Extern2 Priority 10 50 1100 1200 2200 2300 2400 3100 3200 3300

To change the relative route priority, use the following command:


configure iproute ipv6 priority [ripng | blackhole | icmp | static | ospfv3-intra | ospfv3-inter | ospfv3-as-external | ospfv3-extern1 | ospfv3-extern2] <priority>

ExtremeWare XOS 11.3 Concepts Guide

521

IPv6 Unicast Routing

Configuring IP Unicast Routing


This section describes the commands associated with configuring IP unicast routing on the switch. To configure routing: 1 Create and configure two or more VLANs. 2 Assign each VLAN that will be using routing an IP address using the following command:
configure vlan <vlan_name> ipaddress [<ipaddress> {<ipNetmask>} | ipv6-link-local | {eui64} <ipv6_address_mask>]

Ensure that each VLAN has a unique IP address. 3 Configure a default route using the following command:
configure iproute add default [<ipv6Gateway> | <ipv6ScopedGateway>] {vr <vrname>} {<metric>} {multicast-only | unicast-only}

Default routes are used when the router has no other dynamic or static route to the requested destination. 4 Turn on IP routing for one or all VLANs using the following command:
enable ipforwarding ipv6 {vlan <vlan_name> | tunnel <tunnel-name> | vr <vr_name>}

5 Configure the routing protocol, if required. For a simple network using RIPng, the default configuration may be acceptable. 6 Turn on RIPng or OSPFv3 using one of the following commands:
enable ripng enable ospfv3 {domain <domainName>}

Verifying the IP Unicast Routing Configuration


Use the show iproute ipv6 command to display the current configuration of IP unicast routing for the switch and for each VLAN. The show iproute ipv6 command displays the currently configured routes and includes how each route was learned. Additional verification commands include:

show neighbor-discovery cache ipv6Displays the neighbor discovery cache of the system. show ipconfig ipv6Displays configuration information for one or more VLANs.

Routing Configuration Example


Figure 63 illustrates a BlackDiamond switch that has three VLANs defined as follows:

Finance

Protocol-sensitive VLAN using IPv6 protocol All ports on slots 1 and 3 have been assigned. IP address 2001:db8:35::1/48. Protocol-sensitive VLAN using the IPv6 protocol. All ports on slots 2 and 4 have been assigned.

Personnel

522

ExtremeWare XOS 11.3 Concepts Guide

Routing Configuration Example


IP address 2001:db8:36::1/48. Port-based VLAN. All ports on slots 1 through 4 have been assigned.

MyCompany

Figure 63: IPv6 Unicast routing configuration example

2001:db8:35::1/48

2001:db8:36::1/48

MyCompany 2001:db8:35::/48 Finance 2001:db8:36::/48 Personnel

IPv6 NetBIOS IPv6 NetBIOS

IPv6 NetBIOS IPv6 NetBIOS

= IPv6 traffic = NetBIOS traffic


EX_106

The stations connected to the system generate a combination of IPv6 traffic and NetBIOS traffic. The IPv6 traffic is filtered by the protocol-sensitive VLANs. All other traffic is directed to the VLAN MyCompany. In this configuration, all IPv6 traffic from stations connected to slots 1 and 3 have access to the router by way of the VLAN Finance. Ports on slots 2 and 4 reach the router by way of the VLAN Personnel. All other traffic (NetBIOS) is part of the VLAN MyCompany. The example is configured as follows:
create vlan Finance create vlan Personnel create vlan MyCompany configure Finance protocol ipv6 configure Personnel protocol ipv6 configure Finance add port 1:*,3:* configure Personnel add port 2:*,4:* configure MyCompany add port all

ExtremeWare XOS 11.3 Concepts Guide

523

IPv6 Unicast Routing


configure configure configure configure Finance ipaddress 2001:db8:35::1/48 Personnel ipaddress 2001:db8:36::1/48 ripng add vlan Finance ripng add vlan Personnel

enable ipforwarding ipv6 enable ripng

Tunnel Configuration Examples


ExtremeWare XOS supports two types of tunnels, IPv6-in-IPv4 tunnels (known as configured tunnels or 6in4 tunnels) and IPv6-to-IPv4 tunnels (known as 6to4 tunnels). Both types of tunnels can be used to connect regions of IPv6 routing across a region of IPv4 routing. From the perspective of the router, the tunnel across the IPv4 region is one hop, even if multiple IPv4 routers are traversed during transport. A 6in4 tunnel connects one IPv6 region to one other IPv6 region. Multiple 6in4 tunnels can be configured on a single router to connect with other IPv6 regions. Dynamic and static routing can be configured across a 6in4 tunnel. Hosts in the IPv6 regions need know nothing about the configured tunnel, since packets destined for remote regions are sent over the tunnel like any other type of routing interface. A 6to4 tunnel connects one IPv6 region with multiple IPv6 regions. Only one 6to4 tunnel can be configured on a single router. Hosts in the IPv6 regions connected by 6to4 tunnels must be configured with 2002::/16 6to4 addresses in order for traffic to flow. ExtremeWare XOS does not support 6to4 relay router functionality.

524

ExtremeWare XOS 11.3 Concepts Guide

Tunnel Configuration Examples

6in4 Tunnel Configuration Example


Figure 64 illustrates a 6in4 tunnel configured between two IPv6 regions across an IPv4 region.

Figure 64: 6in4 Tunnel Example

Host A
2001:db8:1::101/64

Router A
2
2001:db8:1::1/64

IPv6

1 2001:db8:a::1/64
192.168.1.1/24

IPv4

Router B IPv6
2001:db8:a::2/64 1 10.2.0.1/24

2001:db8:2::1/64 2

Host B
2001:db8:2::101/64
EX_108

In Figure 64, Router A has an interface to an IPv4 region with the address 192.168.1.1 (for this example we are using private IPv4 addresses, but to tunnel across the Internet, you would use a public address). Router B has an IPv4 interface of 10.2.0.1. The IPv4 interface must be created before the tunnel is configured and cannot be deleted until the tunnel is deleted. This example has one subnet in each IPv6 region, 2001:db8:1::/64 for Router A and 2001:db8:2::/64 for Router B. Hosts A and B are configured to use IPv6 addresses 2001:db8:1::101 and 2001:db8:2::101 respectively. In order for traffic to move from one region to the other, there must be a route. In this example, a static route is created, but you could enable RIPng or OSPFv3 on the tunnel interface. In this example, we assume that the IPv4 network can route from Router A to Router B (in other words, some IPv4 routing protocol is running on the public-ipv4 interfaces). However, you do not need to enable IPv4 forwarding on the public interfaces in this example unless you are also routing IPv4 traffic on them (in this example, it is assumed you are running no IPv4 traffic inside your respective IPv6 networks, although you could).

ExtremeWare XOS 11.3 Concepts Guide

525

IPv6 Unicast Routing

Router A
configure vlan default delete port all create vlan public-ipv4 configure vlan public-ipv4 add port 1 untagged configure vlan public-ipv4 ipaddress 192.168.1.1/24 create tunnel public6in4 ipv6-in-ipv4 destination 10.2.0.1 source 192.168.1.1 configure tunnel public6in4 ipaddress 2001:db8:a::1/64 enable ipforwarding ipv6 public6in4 create vlan private-ipv6 configure vlan private-ipv6 add port 2 untagged configure vlan private-ipv6 ipaddress 2001:db8:1::1/64 enable ipforwarding ipv6 private-ipv6 configure iproute add 2001:db8:2::/64 2001:db8:a::2

Router B
configure vlan default delete port all create vlan public-ipv4 configure vlan public-ipv4 add port 1 untagged configure vlan public-ipv4 ipaddress 10.2.0.1/24 create tunnel public6in4 ipv6-in-ipv4 destination 192.168.1.1 source 10.2.0.1 configure tunnel public6in4 ipaddress 2001:db8:a::2/64 enable ipforwarding ipv6 public6in4 create vlan private-ipv6 configure vlan private-ipv6 add port 2 untagged configure vlan private-ipv6 ipaddress 2001:db8:2::1/64 enable ipforwarding ipv6 private-ipv6 configure iproute add 2001:db8:1::/64 2001:db8:a::1

526

ExtremeWare XOS 11.3 Concepts Guide

Tunnel Configuration Examples

6to4 Tunnel Configuration Example


Figure 65 illustrates a 6to4 tunnel configured between two IPv6 regions across an IPv4 region.

Figure 65: 6to4 Tunnel Configuration Example

Host 1
2002:c0a8:101::204:96ff:fe1f:a52a/48

Router 1
2
2002:c0a8:101::2/48

1 2002:c0a8:101::1/16

IPv6

192.168.1.1/24

IPv4

Router 2 IPv6
2002:a00:1::1/16 10.0.0.1/24 2002:a00:1:1::1/64 2002:a00:1:2::1/64

1 2 3

Host 2
2002:a00:1:1:204:96ff:fe1f:a432/64

Host 3
2002:a00:1:2:201:30ff:fe00:c200/64
EX_109

In Figure 65, Router 1 has an interface to an IPv4 region with the address 192.168.1.1 (for this example we are using private IPv4 addresses, but to tunnel across the Internet, you would use a public address). Router 2 has an IPv4 interface of 10.0.0.1. The IPv4 interface must be created before the tunnel is configured and cannot be deleted until the tunnel is deleted. The IPv6 endpoints of 6to4 tunnels must follow the standard 6to4 address requirement. The address must be of the form 2002:<IPv4_source_endpoint>::/16, where <IPv4_source_endpoint> is replaced by the IPv4 source address of the endpoint, in hexadecimal, colon separated form. For example, for a tunnel endpoint located at IPv4 address 10.20.30.40, the tunnel address would be 2002:0a14:1e28::/16. In hex, 10 is 0a, 20 is 14, 30 is 1e and 40 is 28. This example shows a simple setup on the Router 1 side (one big /48 IPv6 routing domain with no subnets), and a slightly more complex setup on the Router 2 side (two subnets :0001: and :0002: that are /64 in length). Hosts 1, 2, and 3 will communicate using their global 2002: addresses. The hosts in this example configure themselves using the EUI64 interface identifier derived from their MAC addresses. Refer to your host OS vendors documentation for configuring IPv6 addresses and routes.

ExtremeWare XOS 11.3 Concepts Guide

527

IPv6 Unicast Routing In this example, we assume that the IPv4 network can route from Router 1 to Router 2 (in other words, some IPv4 routing protocol is running on the public-ipv4 interfaces). However, you do not need to enable IPv4 forwarding on the public interfaces in this example unless you are also routing IPv4 traffic on them (in this example, it is assumed you are running no IPv4 traffic inside your respective IPv6 networks, although you could).

Router 1
configure vlan default delete port all create vlan public-ipv4 configure vlan public-ipv4 add port 1 untagged configure vlan public-ipv4 ipaddress 192.168.1.1/24 create tunnel public6to4 6to4 source 192.168.1.1 configure tunnel public6to4 ipaddress 2002:c0a8:0101::1/16 enable ipforwarding ipv6 public6to4 create vlan private-ipv6 configure vlan private-ipv6 add port 2 untagged configure vlan private-ipv6 ipaddress 2002:c0a8:0101::2/48 enable ipforwarding ipv6 private-ipv6

Router 2
configure vlan default delete port all create vlan public-ipv4 configure vlan public-ipv4 add port 1 untagged configure vlan public-ipv4 ipaddress 10.0.0.1/24 create tunnel public6to4 6to4 source 10.0.0.1 configure tunnel public6to4 ipaddress 2002:0a00:0001::1/16 enable ipforwarding ipv6 public6to4 create vlan private-ipv6-sub1 configure vlan private-ipv6-sub1 add port 2 untagged configure vlan private-ipv6-sub1 ipaddress 2002:0a00:0001:0001::1/64 enable ipforwarding ipv6 private-ipv6-sub1 create vlan private-ipv6-sub2 configure vlan private-ipv6-sub2 add port 3 untagged configure vlan private-ipv6-sub2 ipaddress 2002:0a00:0001:0002::1/64 enable ipforwarding ipv6 private-ipv6-sub2

Host Configurations
The IPv6 addresses of these hosts are based on their MAC address-derived EUI64 interface identifiers and the address prefixes for their subnets. Each host must also have a static route configured on it for 6to4 addresses. Host 1:

MAC address00:04:96:1F:A5:2A IPv6 address2002:c0a8:0101::0204:96ff:fe1f:a52a/48 Static routedestination 2002::/16, gateway 2002:c0a8:0101::2

528

ExtremeWare XOS 11.3 Concepts Guide

Tunnel Configuration Examples Host 2:


MAC address00:04:96:1F:A4:32 IP address2002:0a00:0001:0001:0204:96ff:fe1f:a432/64 Static routedestination 2002::/16, gateway 2002:0a00:0001:0001::1

Host 3:

MAC address00:01:30:00:C2:00 IP address2002:0a00:0001:0002:0201:30ff:fe00:c200/64 Static routedestination 2002::/16, gateway 2002:0a00:0001:0002::1

ExtremeWare XOS 11.3 Concepts Guide

529

IPv6 Unicast Routing

530

ExtremeWare XOS 11.3 Concepts Guide

25 RIP
This chapter describes the following topics:

Overview on page 531 Overview of RIP on page 532 Route Redistribution on page 533 RIP Configuration Example on page 535

This chapter assumes that you are already familiar with IP unicast routing. If not, refer to the following publications for additional information:

RFC 1058Routing Information Protocol (RIP) RFC 1723RIP Version 2 Interconnections: Bridges and Routers by Radia Perlman ISBN 0-201-56332-0 Published by Addison-Wesley Publishing Company

Overview
The switch supports the use of two interior gateway protocols (IGPs); the Routing Information Protocol (RIP), and the Open Shortest Path First (OSPF) protocol. RIP is a distance-vector protocol, based on the Bellman-Ford (or distance-vector) algorithm. The distance-vector algorithm has been in use for many years and is widely deployed and understood. OSPF is a link-state protocol, based on the Dijkstra link-state algorithm. OSPF is a newer IGP and solves a number of problems associated with using RIP on todays complex networks.

NOTE
RIP and OSPF can be enabled on a single VLAN.

RIP is described in this chapter, and OSPF is described in Chapter 27, OSPF on page 543.

RIP Versus OSPF


The distinction between RIP and OSPF lies in the fundamental differences between distance-vector protocols and link-state protocols. Using a distance-vector protocol, each router creates a unique routing table from summarized information obtained from neighboring routers. Using a link-state protocol, every router maintains an identical routing table created from information obtained from all routers in the autonomous system (AS). Each router builds a shortest path tree, using itself as the root. The linkstate protocol ensures that updates sent to neighboring routers are acknowledged by the neighbors, verifying that all routers have a consistent network map.

ExtremeWare XOS 11.3 Concepts Guide

531

RIP

Advantages of RIP and OSPF


The biggest advantage of using RIP is that it is relatively simple to understand and to implement, and it has been the de facto routing standard for many years. RIP has a number of limitations that can cause problems in large networks, including the following:

A limit of 15 hops between the source and destination networks. A large amount of bandwidth taken up by periodic broadcasts of the entire routing table. Slow convergence. Routing decisions based on hop count; no concept of link costs or delay. Flat networks; no concept of areas or boundaries.

OSPF offers many advantages over RIP, including the following:


No limitation on hop count. Route updates multicast only when changes occur. Faster convergence. Support for load balancing to multiple routers based on the actual cost of the link. Support for hierarchical topologies where the network is divided into areas.

The details of RIP are explained later in this chapter.

Overview of RIP
RIP is an IGP first used in computer routing in the Advanced Research Projects Agency Network (ARPAnet) as early as 1969. It is primarily intended for use in homogeneous networks of moderate size. To determine the best path to a distant network, a router using RIP always selects the path that has the least number of hops. Each router that data must traverse is considered to be one hop.

Routing Table
The routing table in a router using RIP contains an entry for every known destination network. Each routing table entry contains the following information:

IP address of the destination network Metric (hop count) to the destination network IP address of the next router Timer that tracks the amount of time since the entry was last updated

The router exchanges an update message with each neighbor every 30 seconds (default value), or when there is a change to the overall routed topology (also called triggered updates). If a router does not receive an update message from its neighbor within the route timeout period (180 seconds by default), the router assumes the connection between it and its neighbor is no longer available.

532

ExtremeWare XOS 11.3 Concepts Guide

Route Redistribution

Split Horizon
Split horizon is a scheme for avoiding problems caused by including routes in updates sent to the router from which the route was learned. Split horizon omits routes learned from a neighbor in updates sent to that neighbor.

Poison Reverse
Like split horizon, poison reverse is a scheme for eliminating the possibility of loops in the routed topology. In this case, a router advertises a route over the same interface that supplied the route, but the route uses a hop count of 16, which defines that router as unreachable.

Triggered Updates
Triggered updates occur whenever a router changes the metric for a route. The router is required to send an update message immediately, even if it is not yet time for a regular update message to be sent. This generally results in faster convergence, but may also result in more RIP-related traffic.

Route Advertisement of VLANs


Virtual LANs (VLANs) that are configured with an IP address but are configured to not route IP or are not configured to run RIP, do not have their subnets advertised by RIP. RIP advertises only those VLANs that are configured with an IP address, are configured to route IP, and run RIP.

RIP Version 1 Versus RIP Version 2


A new version of RIP, called RIP version 2, expands the functionality of RIP version 1 to include the following:

Variable-length subnet masks (VLSMs). Support for next-hop addresses, which allows for optimization of routes in certain environments. Multicasting. RIP version 2 packets can be multicast instead of being broadcast, reducing the load on hosts that do not support routing protocols. NOTE

If you are using RIP with supernetting/Classless Inter-Domain Routing (CIDR), you must use RIPv2 only.

Route Redistribution
More than one routing protocol can be enabled simultaneously on the switch. Route redistribution allows the switch to exchange routes, including static routes, between the routing protocols. Figure 66 is an example of route redistribution between an OSPF AS and a RIP AS.

ExtremeWare XOS 11.3 Concepts Guide

533

RIP

Figure 66: Route redistribution

OSPF AS
Backbone Area 0.0.0.0

ABR

Area 121.2.3.4

ASBR

ASBR

RIP AS
EX_046

Configuring Route Redistribution


Exporting routes from one protocol to another and from that protocol to the first one are discreet configuration functions. For example, to run OSPF and RIP simultaneously, you must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPF to RIP and the routes to export from RIP to OSPF. Likewise, for any other combinations of protocols, you must separately configure each to export routes to the other.

Redistributing Routes into RIP


Enable or disable the exporting of static, direct, BGP-learned, and OSPF-learned routes into the RIP domain using the following commands:
enable rip export [bgp | direct | e-bgp | i-bgp | ospf | ospf-extern1 | ospf-extern2 | ospf-inter | ospf-intra | static] [cost <number> {tag <number>} | policy <policyname>] disable rip export [bgp | direct | e-bgp | i-bgp | ospf | ospf-extern1 | ospf-extern2 | ospf-inter | ospf-intra | static]

534

ExtremeWare XOS 11.3 Concepts Guide

RIP Configuration Example These commands enable or disable the exporting of static, direct, and OSPF-learned routes into the RIP domain. You can choose which types of OSPF routes are injected, or you can simply choose ospf, which will inject all learned OSPF routes regardless of type. The default setting is disabled.

RIP Configuration Example


Figure 67 illustrates a BlackDiamond switch that has three VLANs defined as follows:

Finance

Protocol-sensitive VLAN using the IP protocol. All ports on slots 1 and 3 have been assigned. IP address 192.207.35.1. Protocol-sensitive VLAN using the IP protocol. All ports on slots 2 and 4 have been assigned. IP address 192.207.36.1. Port-based VLAN. All ports on slots 1 through 4 have been assigned.

Personnel

MyCompany

This example does use protocol-sensitive VLANs that only admit IP packets. This is not a common requirement for most networks. In most cases, VLANs will admit different types of packets to be forwarded to the hosts and servers on the network.

ExtremeWare XOS 11.3 Concepts Guide

535

RIP

Figure 67: RIP configuration example

192.207.35.1

192.207.36.1

MyCompany 192.207.35.0 Finance 192.207.36.0 Personnel

IP NetBIOS IP NetBIOS

IP NetBIOS IP NetBIOS

= IP traffic = NetBIOS traffic


EX_047

The stations connected to the system generate a combination of IP traffic and NetBIOS traffic. The IP traffic is filtered by the protocol-sensitive VLANs. All other traffic is directed to the VLAN MyCompany. In this configuration, all IP traffic from stations connected to slots 1 and 3 have access to the router by way of the VLAN Finance. Ports on slots 2 and 4 reach the router by way of the VLAN Personnel. All other traffic (NetBIOS) is part of the VLAN MyCompany. More commonly, NetBIOS traffic would be allowed on the Finance and Personnel VLANs, but this example shows how to exclude that traffic. To allow the NetBIOS traffic (or other type of traffic) along with the IP traffic, remove the configure finance protocol ip and configure Personnel protocol ip commands from the example. The example in Figure 67 is configured as follows:
create vlan Finance create vlan Personnel create vlan MyCompany configure Finance protocol ip configure Personnel protocol ip configure Finance add port 1:*,3:* configure Personnel add port 2:*,4:* configure MyCompany add port all configure Finance ipaddress 192.207.35.1 configure Personnel ipaddress 192.207.36.1

536

ExtremeWare XOS 11.3 Concepts Guide

RIP Configuration Example

enable ipforwarding configure rip add vlan all enable rip

ExtremeWare XOS 11.3 Concepts Guide

537

RIP

538

ExtremeWare XOS 11.3 Concepts Guide

26 RIPng
This chapter describes the following topics:

Overview on page 539 Overview of RIPng on page 540 Route Redistribution on page 541 RIPng Configuration Example on page 542

This chapter assumes that you are already familiar with IP unicast routing. If not, refer to the following publications for additional information:

RFC 2080RIPng for IPv6

Overview
Routing Information Protocol Next Generation (RIPng) is an interior gateway protocol (IGP) developed for IPv6 networks. The analogous protocol used in IPv4 networks is called Routing Information Protocol (RIP). Like RIP, RIPng is a relatively simple protocol for the communication of routing information among routers. Many concepts and features of RIPng are directly parallel to those same features in RIP. RIPng is a distance-vector protocol, based on the Bellman-Ford (or distance-vector) algorithm. The distance-vector algorithm has been in use for many years and is widely deployed and understood. The other common IGP for IPv6 is OSPFv3, a link-state protocol.

NOTE
RIPng and OSPFv3 can be enabled on a single VLAN.

RIPng is described in this chapter, and OSPFv3 is described in Chapter 28, OSPFv3 on page 557.

RIPng Versus OSPFv3


The distinction between RIPng and OSPFv3 lies in the fundamental differences between distance-vector protocols and link-state protocols. Using a distance-vector protocol, each router creates a unique routing table from summarized information obtained from neighboring routers. Using a link-state protocol, every router maintains an identical routing table created from information obtained from all routers in the autonomous system (AS). Each router builds a shortest path tree, using itself as the root. The linkstate protocol ensures that updates sent to neighboring routers are acknowledged by the neighbors, verifying that all routers have a consistent network map.

ExtremeWare XOS 11.3 Concepts Guide

539

RIPng

Advantages of RIPng and OSPFv3


The biggest advantage of using RIPng is that it is relatively simple to understand and to implement, and it has been the de facto routing standard for many years. RIPng has a number of limitations that can cause problems in large networks, including the following:

A limit of 15 hops between the source and destination networks. A large amount of bandwidth taken up by periodic broadcasts of the entire routing table. Slow convergence. Routing decisions based on hop count; no concept of link costs or delay. Flat networks; no concept of areas or boundaries.

OSPFv3 offers many advantages over RIPng, including the following:


No limitation on hop count. Route updates multicast only when changes occur. Faster convergence. Support for load balancing to multiple routers based on the actual cost of the link. Support for hierarchical topologies where the network is divided into areas.

The details of RIPng are explained later in this chapter.

Overview of RIPng
RIPng is primarily intended for use in homogeneous networks of moderate size. To determine the best path to a distant network, a router using RIPng always selects the path that has the least number of hops. Each router that data must traverse is considered to be one hop.

Routing Table
The routing table in a router using RIPng contains an entry for every known destination network. Each routing table entry contains the following information:

IP address and prefix length of the destination network Metric (hop count) to the destination network IP address of the next hop router, if the destination is not directly connected Interface for the next hop Timer that tracks the amount of time since the entry was last updated A flag that indicates if the entry is a new one since the last update The source of the route, for example, static, RIPng, OSPFv3, etc.

The router exchanges an update message with each neighbor every 30 seconds (default value), or when there is a change to the overall routed topology (also called triggered updates). If a router does not receive an update message from its neighbor within the route timeout period (180 seconds by default), the router assumes the connection between it and its neighbor is no longer available.

540

ExtremeWare XOS 11.3 Concepts Guide

Route Redistribution

Split Horizon
Split horizon is a scheme for avoiding problems caused by including routes in updates sent to the router from which the route was learned. Split horizon omits routes learned from a neighbor in updates sent to that neighbor.

Poison Reverse
Like split horizon, poison reverse is a scheme for eliminating the possibility of loops in the routed topology. In this case, a router advertises a route over the same interface that supplied the route, but the route uses a hop count of 16, which defines that router as unreachable.

Triggered Updates
Triggered updates occur whenever a router changes the metric for a route. The router is required to send an update message immediately, even if it is not yet time for a regular update message to be sent. This generally results in faster convergence, but may also result in more RIPng-related traffic.

Route Advertisement of VLANs


Virtual LANs (VLANs) that are configured with an IP address but are configured to not route IP or are not configured to run RIP, do not have their subnets advertised by RIP. RIP advertises only those VLANs that are configured with an IP address, are configured to route IP, and run RIP.

Route Redistribution
More than one routing protocol can be enabled simultaneously on the switch. Route redistribution allows the switch to exchange routes, including static routes, between the routing protocols. Route redistribution is also called route export.

Configuring Route Redistribution


Exporting routes from one protocol to another and from that protocol to the first one are discreet configuration functions. For example, to run OSPFv3 and RIPng simultaneously, you must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPFv3 to RIPng and the routes to export from RIPng to OSPFv3. Likewise, for any other combinations of protocols, you must separately configure each to export routes to the other.

Redistributing Routes into RIPng


Enable or disable the exporting of static, direct, or other protocol-learned routes into the RIPng domain using the following commands:
enable ripng export [direct | ospfv3 | ospfv3-extern1 | ospfv3-extern2 | ospfv3inter | ospfv3-intra | static] [cost <number> {tag <number>} | policy <policy-name>]

ExtremeWare XOS 11.3 Concepts Guide

541

RIPng

disable ripng export [direct | ospfv3 | ospfv3-extern1 | ospfv3-extern2 | ospfv3-inter | ospfv3-intra | static]

These commands enable or disable the exporting of static, direct, and OSPF-learned routes into the RIPng domain. You can choose which types of OSPF routes are injected, or you can simply choose ospf, which will inject all learned OSPF routes regardless of type. The default setting is disabled.

RIPng Configuration Example


The following configuration is similar to the example in the RIP chapter, but uses IPv6 addresses. It illustrates a BlackDiamond switch that has three VLANs defined as follows:

Finance

All ports on slots 1 and 3 have been assigned. IP address 2001:db8:35::1/48. All ports on slots 2 and 4 have been assigned. IP address 2001:db8:36::1/48. Port-based VLAN. All ports on slots 1 through 4 have been assigned.

Personnel

MyCompany

The stations connected to the system generate a combination of IPv6 traffic and NetBIOS traffic. In this configuration, all traffic from stations connected to slots 1 and 3 have access to the router by way of the VLAN Finance. Ports on slots 2 and 4 reach the router by way of the VLAN Personnel. All traffic (NetBIOS and IPv6) is part of the VLAN MyCompany. The example is configured as follows:
create vlan Finance create vlan Personnel create vlan MyCompany configure Finance add port 1:*,3:* configure Personnel add port 2:*,4:* configure MyCompany add port all configure Finance ipaddress 2001:db8:35::1/48 configure Personnel ipaddress 2001:db8:36::1/48 enable ipforwarding ipv6 configure ripng add vlan Finance configure ripng add vlan Personnel enable ripng

542

ExtremeWare XOS 11.3 Concepts Guide

27 OSPF
This chapter covers the following topics:

Overview of OSPF on page 543 Route Redistribution on page 550 Configuring OSPF on page 551 OSPF Configuration Example on page 553 Displaying OSPF Settings on page 555

This chapter assumes that you are already familiar with IP unicast routing. If not, refer to the following publications for additional information:

RFC 2328OSPF Version 2 RFC 1765OSPF Database Overflow RFC 2370The OSPF Opaque LSA Option RFC 3101The OSPF Not-So-Stubby Area (NSSA) Option RFC 3623Graceful OSPF Restart Interconnections: Bridges and Routers by Radia Perlman ISBN 0-201-56332-0 Published by Addison-Wesley Publishing Company

Overview of OSPF
Open Shortest Path First (OSPF) is a link state protocol that distributes routing information between routers belonging to a single IP domain; the IP domain is also known as an autonomous system (AS). In a link-state routing protocol, each router maintains a database describing the topology of the AS. Each participating router has an identical database maintained from the perspective of that router. From the link state database (LSDB), each router constructs a tree of shortest paths, using itself as the root. The shortest path tree provides the route to each destination in the AS. When several equal-cost routes to a destination exist, traffic can be distributed among them. The cost of a route is described by a single metric. OSPF is an interior gateway protocol (IGP), as is the other common IGP, RIP. OSPF and are compared in Chapter 25, RIP on page 531.

Licensing
To use the complete OSPF functionality, you must have a Core license installed on your switch. The BlackDiamond 10K ships with a Core, or Advanced Core license. Other platforms can be upgraded to a Core license. See the section Software Licensing on page 33 for more information about licensing. A subset of OSPF, called OSPF Edge Mode, is available with an Advanced Edge license.

ExtremeWare XOS 11.3 Concepts Guide

543

OSPF

OSPF Edge Mode


OSPF Edge Mode is a subset of OSPF available on platforms with an Advanced Edge license. There are two restrictions on OSPF Edge Mode:

At most, two Active OSPF VLAN interfaces are permitted. There is no restriction on the number of Passive interfaces. The OSPF Priority on VLANs is zero, and is not configurable. This prevents the system from acting as a DR or BDR

Link State Database


Upon initialization, each router transmits a link state advertisement (LSA) on each of its interfaces. LSAs are collected by each router and entered into the LSDB of each router. Once all LSAs are received, the router uses the LSDB to calculate the best routes for use in the IP routing table. OSPF uses flooding to distribute LSAs between routers. Any change in routing information is sent to all of the routers in the network. All routers within an area have the exact same LSDB. Table 67 describes LSA type numbers.

Table 67: LSA type numbers


Type Number 1 2 3 4 5 7 9 10 11 Description Router LSA Network LSA Summary LSA AS summary LSA AS external LSA NSSA external LSA Link localOpaque Area scopingOpaque AS scopingOpaque

Database Overflow
The OSPF database overflow feature allows you to limit the size of the LSDB and to maintain a consistent LSDB across all the routers in the domain, which ensures that all routers have a consistent view of the network. Consistency is achieved by:

Limiting the number of external LSAs in the database of each router. Ensuring that all routers have identical LSAs.

To configure OSPF database overflow, use the following command:


configure ospf ase-limit <number> {timeout <seconds>}

where:

<number>Specifies the number of external LSAs that the system supports before it goes into overflow state. A limit value of zero disables the functionality.

When the LSDB size limit is reached, OSPF database overflow flushes LSAs from the LSDB. OSPF database overflow flushes the same LSAs from all the routers, which maintains consistency.

544

ExtremeWare XOS 11.3 Concepts Guide

Overview of OSPF

timeoutSpecifies the timeout, in seconds, after which the system ceases to be in overflow state. A

timeout value of zero leaves the system in overflow state until OSPF is disabled and re-enabled.

Opaque LSAs
Opaque LSAs are a generic OSPF mechanism used to carry auxiliary information in the OSPF database. Opaque LSAs are most commonly used to support OSPF traffic engineering. Normally, support for opaque LSAs is autonegotiated between OSPF neighbors. In the event that you experience interoperability problems, you can disable opaque LSAs across the entire system using the following command:
enable ospf capability opaque-lsa

To re-enable opaque LSAs across the entire system, use the following command:
enable ospf capability opaque-lsa

If your network uses opaque LSAs, Extreme Networks recommends that all routers on your OSPF network support opaque LSAs. Routers that do not support opaque LSAs do not store or flood them. At minimum a well interconnected subsection of your OSPF network must support opaque LSAs to maintain reliability of their transmission.

Graceful OSPF Restart


RFC 3623 describes a way for OSPF control functions to restart without disrupting traffic forwarding. Without graceful restart, adjacent routers will assume that information previously received from the restarting router is stale and wont be used to forward traffic to that router. However, in many cases, two conditions exist that allow the router restarting OSPF to continue to forward traffic correctly. The first condition is that forwarding can continue while the control function is restarted. Most modern router system designs separate the forwarding function from the control function so that traffic can still be forwarded independent of the state of the OSPF function. Routes learned through OSPF remain in the routing table and packets continue to be forwarded. The second condition required for graceful restart is that the network remain stable during the restart period. If the network topology is not changing, the current routing table remains correct. Often, networks can remain stable during the time for restarting OSPF.

Restarting and Helper Mode


Routers involved with graceful restart fill one of two roles: the restarting router or the helper router. With graceful restart, the router that is restarting sends out Grace-LSAs informing its neighbors that it is in graceful restart mode, how long the helper router should assist with the restart (the grace period), and why the restart occurred. If the neighboring routers are configured to help with the graceful restart (helper-mode), they will continue to advertise the restarting router as if it was fully adjacent. Traffic continues to be routed as though the restarting router is fully functional. If the network topology changes, the helper routers will stop advertising the restarting router. The helper router will continue in helper mode until the restarting router indicates successful termination of graceful restart, the Grace-LSAs expire, or the network topology changes. A router can be configured for graceful restart, and for helper-mode separately. A router can be a helper when its neighbor restarts, and can in turn be helped by a neighbor if it restarts.

ExtremeWare XOS 11.3 Concepts Guide

545

OSPF

Planned and Unplanned Restarts


Two types of graceful restarts are defined: planned and unplanned. A planned restart would occur if the software module for OSPF was upgraded, or if the router operator decided to restart the OSPF control function for some reason. The router has advance warning, and is able to inform its neighbors in advance that OSPF is restarting. An unplanned restart would occur if there was some kind of system failure that caused a remote reboot or a crash of OSPF, or an MSM failover occurs. As OSPF restarts, it informs its neighbors that it is in the midst of an unplanned restart. You can decide to configure a router to enter graceful restart for only planned restarts, for only unplanned restarts, or for both. Also, you can separately decide to configure a router to be a helper for only planned, only unplanned, or for both kinds of restarts.

Configuring Graceful OSPF Restart


To configure a router to perform graceful OSPF restart, use the following command:
configure ospf restart [none | planned | unplanned | both]

Since a router can act as a restart helper router to multiple neighbors, you will specify which neighbors to help. To configure a router to act as a graceful OSPF restart helper, use the following command:
configure ospf [vlan [all | <vlan-name>] | area <area-identifier> | virtual-link <router-identifier> <area-identifier>] restart-helper [none | planned | unplanned | both]

The graceful restart period sent out to helper routers can be configured with the following command:
configure ospf restart grace-period <seconds>

By default, a helper router will terminate graceful restart if received LSAs would affect the restarting router. This will occur when the restart-helper receives an LSA that will be flooded to the restarting router or when there is a changed LSA on the restarting router's retransmission list when graceful restart is initiated. You can disable this behavior by using the following command:
disable ospf [vlan [all | <vlan-name>] | area <area-identifier> | virtual-link <router-identifier> <area-identifier>] restart-helper-lsa-check

Areas
OSPF allows parts of a network to be grouped together into areas. The topology within an area is hidden from the rest of the AS. Hiding this information enables a significant reduction in LSA traffic and reduces the computations needed to maintain the LSDB. Routing within the area is determined only by the topology of the area. The three types of routers defined by OSPF are as follows:

Internal router (IR)An internal router has all of its interfaces within the same area. Area border router (ABR)An ABR has interfaces in multiple areas. It is responsible for exchanging summary advertisements with other ABRs. Autonomous system border router (ASBR)An ASBR acts as a gateway between OSPF and other routing protocols, or other autonomous systems.

546

ExtremeWare XOS 11.3 Concepts Guide

Overview of OSPF

Backbone Area (Area 0.0.0.0)


Any OSPF network that contains more than one area is required to have an area configured as area 0.0.0.0, also called the backbone. All areas in an AS must be connected to the backbone. When designing networks, you should start with area 0.0.0.0 and then expand into other areas. NOTE
Area 0.0.0.0 exists by default and cannot be deleted or changed.

The backbone allows summary information to be exchanged between ABRs. Every ABR hears the area summaries from all other ABRs. The ABR then forms a picture of the distance to all networks outside of its area by examining the collected advertisements and adding in the backbone distance to each advertising router. When a VLAN is configured to run OSPF, you must configure the area for the VLAN. If you want to configure the VLAN to be part of a different OSPF area, use the following command:
configure ospf vlan <vlan-name> area <area-identifier>

If this is the first instance of the OSPF area being used, you must create the area first using the following command:
create ospf area <area-identifier>

Stub Areas
OSPF allows certain areas to be configured as stub areas. A stub area is connected to only one other area. The area that connects to a stub area can be the backbone area. External route information is not distributed into stub areas. Stub areas are used to reduce memory consumption and computational requirements on OSPF routers. Use the following command to configure an OSPF area as a stub area:
configure ospf area <area-identifier> stub [summary | nosummary] stub-default-cost <cost>

Not-So-Stubby-Areas
Not-so-stubby-areas (NSSAs) are similar to the existing OSPF stub area configuration option but have the following two additional capabilities:

External routes originating from an ASBR connected to the NSSA can be advertised within the NSSA. External routes originating from the NSSA can be propagated to other areas, including the backbone area.

The command line interface (CLI) command to control the NSSA function is similar to the command used for configuring a stub area, as follows:
configure ospf area <area-identifier> nssa [summary | nosummary] stub-default-cost <cost> {translate}

The translate option determines whether type 7 LSAs are translated into type 5 LSAs. When configuring an OSPF area as an NSSA, the translate should only be used on NSSA border routers, where translation is to be enforced. If translate is not used on any NSSA border router in a NSSA, one of the ABRs for that NSSA is elected to perform translation (as indicated in the NSSA specification). The

ExtremeWare XOS 11.3 Concepts Guide

547

OSPF option should not be used on NSSA internal routers. Doing so inhibits correct operation of the election algorithm.

Normal Area
A normal area is an area that is not:

Area 0 Stub area NSSA

Virtual links can be configured through normal areas. External routes can be distributed into normal areas.

Virtual Links
In the situation when a new area is introduced that does not have a direct physical attachment to the backbone, a virtual link is used. A virtual link provides a logical path between the ABR of the disconnected area and the ABR of the normal area that connects to the backbone. A virtual link must be established between two ABRs that have a common area, with one ABR connected to the backbone. Figure 68 illustrates a virtual link. NOTE
Virtual links cannot be configured through a stub or NSSA area.

Figure 68: Virtual link using area 1 as a transit area


Virtual link

ABR

ABR

Area 2

Area 1

Area 0
EX_044

Virtual links are also used to repair a discontiguous backbone area. For example, in Figure 69, if the connection between ABR1 and the backbone fails, the connection using ABR2 provides redundancy so that the discontiguous area can continue to communicate with the backbone using the virtual link.

548

ExtremeWare XOS 11.3 Concepts Guide

Overview of OSPF

Figure 69: Virtual link providing redundancy


Virtual link

Area 2 ABR 2

ABR 1

Area 1

Area 3

Area 0
EX_045

Point-to-Point Support
You can manually configure the OSPF link type for a VLAN. Table 68 describes the link types.

Table 68: OSPF link types


Link Type Auto Broadcast Number of Routers Varies Any Description ExtremeWare XOS automatically determines the OSPF link type based on the interface type. This is the default setting. Routers must elect a designated router (DR) and a backup designated router (BDR) during synchronization. Ethernet is an example of a broadcast link. This type synchronizes faster than a broadcast link because routers do not elect a DR or BDR. It does not operate with more than two routers on the same VLAN. The Point-to-Point Protocol (PPP) is an example of a point-to-point link. An OSPF point-to-point link supports only zero to two OSPF routers and does not elect a designated router (DR) or backup designated router (BDR). If you have three or more routers on the VLAN, OSPF fails to synchronize if the neighbor is not configured. A passive link does not send or receive OSPF packets.

Point-to-point

Up to 2

Passive

NOTE
The number of routers in an OSPF point-to-point link is determined per VLAN, not per link.

NOTE
All routers in the VLAN must have the same OSPF link type. If there is a mismatch, OSPF attempts to operate, but it may not be reliable.

ExtremeWare XOS 11.3 Concepts Guide

549

OSPF

Route Redistribution
More than one routing protocol can be enabled simultaneously on the switch. Route redistribution allows the switch to exchange routes, including static routes, between the routing protocols. Figure 70 is an example of route redistribution between an OSPF AS and a RIP AS.

Figure 70: Route redistribution

OSPF AS
Backbone Area 0.0.0.0

ABR

Area 121.2.3.4

ASBR

ASBR

RIP AS
EX_046

Configuring Route Redistribution


Exporting routes from one protocol to another and from that protocol to the first one are discreet configuration functions. For example, to run OSPF and RIP simultaneously, you must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPF to RIP and the routes to export from RIP to OSPF. Likewise, for any other combinations of protocols, you must separately configure each to export routes to the other.

Redistributing Routes into OSPF


Enable or disable the exporting of BGP, RIP, static, and direct (interface) routes to OSPF using the following commands:

550

ExtremeWare XOS 11.3 Concepts Guide

Configuring OSPF
enable ospf export [bgp | direct | e-bgp | i-bgp | rip | static] [cost <cost> type [ase-type-1 | ase-type-2] {tag <number>} | <policy-map>] disable ospf export [bgp | direct | e-bgp | i-bgp | rip | static]

These commands enable or disable the exporting of RIP, static, and direct routes by way of LSA to other OSPF routers as AS-external type 1 or type 2 routes. The default setting is disabled. The cost metric is inserted for all Border Gateway Protocol (BGP), RIP, static, and direct routes injected into OSPF. If the cost metric is set to 0, the cost is inserted from the route. For example, in the case of BGP export, the cost equals the multiple exit discriminator (MED) or the path length. The tag value is used only by special routing applications. Use 0 if you do not have specific requirements for using a tag. (The tag value in this instance has no relationship with IEEE 802.1Q VLAN tagging.) The same cost, type, and tag values can be inserted for all the export routes, or policies can be used for selective insertion. When a policy is associated with the export command, the policy is applied on every exported route. The exported routes can also be filtered using policies. Verify the configuration using the command:
show ospf

OSPF Timers and Authentication


Configuring OSPF timers and authentication on a per area basis is a shortcut to applying the timers and authentication to each VLAN in the area at the time of configuration. If you add more VLANs to the area, you must configure the timers and authentication for the new VLANs explicitly. Use the command:
configure ospf vlan [<vlan-name> | all] timer <retransmit-interval> <transit-delay> <hello-interval> <dead-interval> {<wait-timer-interval>}

Configuring OSPF
Each switch that is configured to run OSPF must have a unique router ID. Extreme Networks recommends that you manually set the router ID of the switches participating in OSPF, instead of having the switch automatically choose its router ID based on the highest interface IP address. Not performing this configuration in larger, dynamic environments could result in an older LSDB remaining in use.

Configuring OSPF Wait Interval


ExtremeWare XOS allows you to configure the OSPF wait interval, rather than using the router dead interval. CAUTION
Do not configure OSPF timers unless you are comfortable exceeding OSPF specifications. Non-standard settings may not be reliable under all circumstances.

To specify the timer intervals, use the following commands:

ExtremeWare XOS 11.3 Concepts Guide

551

OSPF
configure ospf area <area-identifier> timer <retransmit-interval> <transit-delay> <hello-interval> <dead-interval> {<wait-timer-interval>} configure ospf virtual-link <router-identifier> <area-identifier> timer <retransmitinterval> <transit-delay> <hello-interval> <dead-interval> configure ospf vlan [<vlan-name> | all] timer <retransmit-interval> <transit-delay> <hello-interval> <dead-interval> {<wait-timer-interval>}

OSPF Wait Interval Parameters


You can configure the following parameters:

Retransmit intervalThe length of time that the router waits before retransmitting an LSA that is not acknowledged. If you set an interval that is too short, unnecessary retransmissions result. The default value is 5 seconds. Transit delayThe length of time it takes to transmit an LSA packet over the interface. The transit delay must be greater than 0. Hello intervalThe interval at which routers send hello packets. Shorter times allow routers to discover each other more quickly but also increase network traffic. The default value is 10 seconds. Dead router wait interval (Dead Interval)The interval after which a neighboring router is declared down because hello packets are no longer received from the neighbor. This interval should be a multiple of the hello interval. The default value is 40 seconds. Router wait interval (Wait Timer Interval)The interval between the interface coming up and the election of the DR and BDR. This interval should be greater than the hello interval. If this time is close to the hello interval, the network synchronizes very quickly but might not elect the correct DR or BDR. The default value is equal to the dead router wait interval. NOTE

The OSPF standard specifies that wait times are equal to the dead router wait interval.

552

ExtremeWare XOS 11.3 Concepts Guide

OSPF Configuration Example

OSPF Configuration Example


Figure 71 is an example of an autonomous system using OSPF routers. The details of this network follow.

Figure 71: OSPF configuration example

Area 0

IR 2
10.0.3.2

10.0.1.1

10.0.1.2 10.0.2.2
_1 0_ 0_ 2

IR 1

3 0_ 0_ _1 HQ

Headquarters

ABR 2

10.0.3.1

ABR 1

HQ

10.0.2.1

161.48.2.2

Los Angeles
LA _1
26

160.26.25.1

160.26.26.1
_2

161.48.2.1
_4 8_

61

160.26.26.2

Ch

160.26.25.2

Area 5

i_1

Virtual link

6_

60

Chicago

Area 6 (stub)
EX_040

Area 0 is the backbone area. It is located at the headquarters and has the following characteristics:

Two internal routers (IR1 and IR2) Two area border routers (ABR1 and ABR2) Network number 10.0.x.x Two identified VLANs (HQ_10_0_2 and HQ_10_0_3)

Area 5 is connected to the backbone area by way of ABR1 and ABR2. It is located in Chicago and has the following characteristics:

Network number 160.26.x.x One identified VLAN (Chi_160_26_26) Two internal routers

ExtremeWare XOS 11.3 Concepts Guide

553

OSPF Area 6 is a stub area connected to the backbone by way of ABR1. It is located in Los Angeles and has the following characteristics:

Network number 161.48.x.x One identified VLAN (LA_161_48_2) Three internal routers Uses default routes for inter-area routing

Two router configurations for the example in Figure 71 are provided in the following section.

Configuration for ABR1


The router labeled ABR1 has the following configuration:
create create create create vlan vlan vlan vlan HQ_10_0_2 HQ_10_0_3 LA_161_48_2 Chi_160_26_26 HQ_10_0_2 ipaddress 10.0.2.1 255.255.255.0 HQ_10_0_3 ipaddress 10.0.3.1 255.255.255.0 LA_161_48_2 ipaddress 161.48.2.2 255.255.255.0 Chi_160_26_26 ipaddress 160.26.26.1 255.255.255.0

configure configure configure configure

vlan vlan vlan vlan

create ospf area 0.0.0.5 create ospf area 0.0.0.6 enable ipforwarding configure configure configure configure configure ospf ospf ospf ospf ospf area 0.0.0.6 stub nosummary stub-default-cost 10 add vlan LA_161_48_2 area 0.0.0.6 add vlan Chi_160_26_26 area 0.0.0.5 add vlan HQ_10_0_2 area 0.0.0.0 add vlan HQ_10_0_3 area 0.0.0.0

enable ospf

Configuration for IR1


The router labeled IR1 has the following configuration:
configure vlan HQ_10_0_1 ipaddress 10.0.1.2 255.255.255.0 configure vlan HQ_10_0_2 ipaddress 10.0.2.2 255.255.255.0 enable ipforwarding configure ospf add vlan all area 0.0.0.0 enable ospf

554

ExtremeWare XOS 11.3 Concepts Guide

Displaying OSPF Settings

Displaying OSPF Settings


You can use a number of commands to display settings for OSPF. To show global OSPF information, use the show ospf command with no options. To display information about one or all OSPF areas, use the following command:
show ospf area {<area-identifier>}

The detail option displays information about all OSPF areas in a detail format. To display information about OSPF interfaces for an area, a VLAN, or for all interfaces, use the following command:
show ospf interfaces {vlan <vlan-name> | area <area-identifier>}

The detail option displays information about all OSPF interfaces in a detail format. ExtremeWare XOS provides several filtering criteria for the show ospf lsdb command. You can specify multiple search criteria, and only those results matching all of the criteria are displayed. This allows you to control the displayed entries in large routing tables. To display the current link-state database, use the following command:
show ospf lsdb {detail | stats} {area [<area-identifier> | all]} {{lstype} [<lstype> | all]} {lsid <lsid-address>{<lsid-mask>}} {routerid <routerid-address> {<routeridmask>}} {interface[[<ip-address>{<ip-mask>} | <ipNetmask>] | vlan <vlan-name>]}

The detail option displays all fields of matching LSAs in a multiline format. The summary option displays several important fields of matching LSAs, one line per LSA. The stats option displays the number of matching LSAs but not any of their contents. If not specified, the default is to display in the summary format. A common use of this command is to omit all optional parameters, resulting in the following shortened form:
show ospf lsdb

The shortened form displays LSAs from all areas and all types in a summary format.

ExtremeWare XOS 11.3 Concepts Guide

555

OSPF

556

ExtremeWare XOS 11.3 Concepts Guide

28 OSPFv3
This chapter covers the following topics:

Overview of OSPFv3 on page 557 Route Redistribution on page 561

Overview of OSPFv3
Open Shortest Path First (OSPF) is a link state protocol that distributes routing information between routers belonging to a single IP domain; the IP domain is also known as an autonomous system (AS). In a link-state routing protocol, each router maintains a database describing the topology of the AS. Each participating router has an identical database for an area maintained from the perspective of that router. From the link state database (LSDB), each router constructs a tree of shortest paths, using itself as the root. The shortest path tree provides the route to each destination in the AS. When several equal-cost routes to a destination exist, traffic can be distributed among them. The cost of a route is described by a single metric. OSPFv3 supports IPv6, and uses commands only slightly modified from that used to support IPv4. OSPFv3 has retained the use of the four-byte, dotted decimal numbers for router IDs, LSA IDs, and area IDs. OSPFv3 is an interior gateway protocol (IGP), as is the other common IGP for IPv6, RIPng. OSPFv3 and RIPng are compared in Chapter 26, RIPng on page 539.

Licensing
To use OSPFv3, you must have a Core license installed on your switch. The BlackDiamond 10K ships with a Core, or Advanced Core license. Other platforms can be upgraded to a Core license. See the section Software Licensing on page 33 for more information about licensing.

Link State Database


Upon initialization, each router transmits a link state advertisement (LSA) on each of its interfaces. LSAs are collected by each router and stored into the LSDB of each router. Once all LSAs are received, the router uses the LSDB to calculate the best routes for use in the IP routing table. OSPFv3 uses flooding to distribute LSAs between routers. Any change in routing information is sent to all of the routers in the network. All routers within an area have the exact same LSDB. Table 69 describes LSA type numbers.

Table 69: Selected OSPFv3 LSA types


Type Number 0x0008 0x2001 Description Link LSA Router LSA

ExtremeWare XOS 11.3 Concepts Guide

557

OSPFv3

Table 69: Selected OSPFv3 LSA types (Continued)


Type Number 0x2002 0x2003 0x2004 0x2009 0x4005 Description Network LSA Inter-Area-Prefix LSA Inter-Area-Router LSA Intra-Area-Prefix LSA AS external LSA

Areas
OSPFv3 allows parts of a network to be grouped together into areas. The topology within an area is hidden from the rest of the AS. Hiding this information enables a significant reduction in LSA traffic and reduces the computations needed to maintain the LSDB. Routing within the area is determined only by the topology of the area. The three types of routers defined by OSPFv3 are as follows:

Internal router (IR)An internal router has all of its interfaces within the same area. Area border router (ABR)An ABR has interfaces in multiple areas. It is responsible for exchanging summary advertisements with other ABRs. Autonomous system border router (ASBR)An ASBR acts as a gateway between OSPFv3 and other routing protocols, or other autonomous systems.

Backbone Area (Area 0.0.0.0)


Any OSPFv3 network that contains more than one area is required to have an area configured as area 0.0.0.0, also called the backbone. All areas in an AS must be connected to the backbone. When designing networks, you should start with area 0.0.0.0 and then expand into other areas. NOTE
Area 0.0.0.0 exists by default and cannot be deleted or changed.

The backbone allows summary information to be exchanged between ABRs. Every ABR hears the area summaries from all other ABRs. The ABR then forms a picture of the distance to all networks outside of its area by examining the collected advertisements and adding in the backbone distance to each advertising router. When a VLAN is configured to run OSPFv3, you must configure the area for the VLAN. If you want to configure the VLAN to be part of a different OSPFv3 area, use the following command:
configure ospfv3 {domain <domainName>} [vlan <vlan-name> | tunnel <tunnel-name>] area <area-identifier>

If this is the first instance of the OSPFv3 area being used, you must create the area first using the following command:
create ospfv3 {domain <domainName>} area <area-identifier>

558

ExtremeWare XOS 11.3 Concepts Guide

Overview of OSPFv3

Stub Areas
OSPFv3 allows certain areas to be configured as stub areas. A stub area is connected to only one other area. The area that connects to a stub area can be the backbone area. External route information is not distributed into stub areas. Stub areas are used to reduce memory consumption and computational requirements on OSPFv3 routers. Use the following command to configure an OSPFv3 area as a stub area:
configure ospfv3 {domain <domainName>} area <area-identifier> stub [summary | nosummary] stub-default-cost <cost>

Not-So-Stubby-Areas
Not-so-stubby-areas (NSSAs) are not supported currently in the ExtremeWare XOS implementation of OSPFv3.

Normal Area
A normal area is an area that is not:

Area 0 Stub area NSSA

Virtual links can be configured through normal areas. External routes can be distributed into normal areas.

Virtual Links
In the situation when a new area is introduced that does not have a direct physical attachment to the backbone, a virtual link is used. A virtual link provides a logical path between the ABR of the disconnected area and the ABR of the normal area that connects to the backbone. A virtual link must be established between two ABRs that have a common area, with one ABR connected to the backbone. Figure 72 illustrates a virtual link. NOTE
Virtual links cannot be configured through a stub or NSSA area.

ExtremeWare XOS 11.3 Concepts Guide

559

OSPFv3

Figure 72: Virtual link using area 1 as a transit area


Virtual link

ABR

ABR

Area 2

Area 1

Area 0
EX_044

Virtual links are also used to repair a discontiguous backbone area. For example, in Figure 73, if the connection between ABR1 and the backbone fails, the connection using ABR2 provides redundancy so that the discontiguous area can continue to communicate with the backbone using the virtual link.

Figure 73: Virtual link providing redundancy


Virtual link

Area 2 ABR 2

ABR 1

Area 1

Area 3

Area 0
EX_045

Link-Type Support
You can manually configure the OSPFv3 link type for a VLAN. Table 70 describes the link types.

Table 70: OSPFv3 link types


Link Type Auto Number of Routers Varies Description ExtremeWare XOS automatically determines the OSPFv3 link type based on the interface type. This is the default setting.

560

ExtremeWare XOS 11.3 Concepts Guide

Route Redistribution

Table 70: OSPFv3 link types (Continued)


Link Type Broadcast Number of Routers Any Description Routers must elect a designated router (DR) and a backup designated router (BDR) during synchronization. Ethernet is an example of a broadcast link. A passive link does not send or receive OSPFv3 packets.

Passive

NOTE
The number of routers in an OSPFv3 point-to-point link is determined per VLAN, not per link.

NOTE
All routers in the VLAN must have the same OSPFv3 link type. If there is a mismatch, OSPFv3 attempts to operate, but it may not be reliable.

Route Redistribution
More than one routing protocol can be enabled simultaneously on the switch. Route redistribution allows the switch to exchange routes, including static routes, between the routing protocols. Figure 74 is an example of route redistribution between an OSPFv3 AS and a RIPng AS.

ExtremeWare XOS 11.3 Concepts Guide

561

OSPFv3

Figure 74: Route redistribution

OSPF AS
Backbone Area 0.0.0.0

ABR

Area 121.2.3.4

ASBR

ASBR

RIP AS
EX_046

Configuring Route Redistribution


Exporting routes from one protocol to another and from that protocol to the first one are discreet configuration functions. For example, to run OSPFv3 and RIPng simultaneously, you must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPFv3 to RIPng and the routes to export from RIPng to OSPFv3. Likewise, for any other combinations of protocols, you must separately configure each to export routes to the other.

Redistributing Routes into OSPFv3


Enable or disable the exporting of RIPng, static, and direct (interface) routes to OSPFv3 using the following commands:
enable ospfv3 {domain <domainName>} export [direct | ripng | static] [cost <cost> type [ase-type-1 | ase-type-2] {tag <number>} | <policy-map>] disable ospfv3 {domain <domainName>} export [direct | ripng | static]

These commands enable or disable the exporting of RIPng, static, and direct routes by way of LSA to other OSPFv3 routers as AS-external type 1 or type 2 routes. The default setting is disabled.

562

ExtremeWare XOS 11.3 Concepts Guide

OSPFv3 Configuration Example The cost metric is inserted for all RIPng, static, and direct routes injected into OSPFv3. If the cost metric is set to 0, the cost is inserted from the route. The tag value is used only by special routing applications. Use 0 if you do not have specific requirements for using a tag. (The tag value in this instance has no relationship with IEEE 802.1Q VLAN tagging.) The same cost, type, and tag values can be inserted for all the export routes, or policies can be used for selective insertion. When a policy is associated with the export command, the policy is applied on every exported route. The exported routes can also be filtered using policies. Verify the configuration using the command:
show ospfv3 {domain <domainName>}

OSPFv3 Timers
Configuring OSPFv3 timers on a per area basis is a shortcut to applying the timers to each VLAN in the area at the time of configuration. If you add more VLANs to the area, you must configure the timers for the new VLANs explicitly. Use the command:
configure ospfv3 {domain <domainName>} [vlan <vlan-name> | tunnel <tunnel-name> | [vlan | tunnel] all] timer {retransmit-interval} <retransmit-interval> {transit-delay} <transit-delay> {hello-interval} <hello-interval> {dead-interval} <dead-interval>

OSPFv3 Configuration Example


Figure 75 is an example of an autonomous system using OSPFv3 routers. The details of this network follow.

ExtremeWare XOS 11.3 Concepts Guide

563

OSPFv3

Figure 75: OSPFv3 configuration example


Router 2
2001:db8:4444:6666::2/64

Area 0.0.0.0

to-r2

Router 1

2001:db8:4444:6666::1/64

2001:db8:3333:5555::1/64

Router 3
to-r3

2001:db8:3333:5555::2/64

Area 0.0.0.1
EX_107

In Figure 75 there are three Extreme Networks switches running ExtremeWare XOS images that have support for OSPFv3. Router 1 is an area border router and is connected to two other switches Router 2 and Router 3. Router 1 runs OSPFv3 on both the links connecting it to Router 2 and Router 3. The router configurations for the example in Figure 75 are provided in the following section. After doing all the configurations, Router 1 will establish OSPFv3 adjacency with Router 2 and Router 3. They will also exchange the various link state databases.

Configuration for Router 1


The router labeled Router 1 has the following configuration:
create vlan to-r2 create vlan to-r3 configure vlan to-r2 ipaddress 2001:db8:4444:6666::1/64 configure vlan to-r3 ipaddress 2001:db8:3333:5555::1/64 configure vlan to-r2 add port 1:1 configure vlan to-r3 add port 1:2 enable ipforwarding ipv6 configure ospfv3 routerid 0.0.0.1

564

ExtremeWare XOS 11.3 Concepts Guide

OSPFv3 Configuration Example


configure ospfv3 add vlan to-r2 area 0.0.0.0 create ospfv3 area 0.0.0.1 configure ospfv3 add vlan to-r3 area 0.0.0.1 enable ospfv3

Configuration for Router 2


The router labeled Router 2 has the following configuration:
create vlan to-r1 configure vlan to-r1 ipaddress 2001:db8:4444:6666::2/64 configure vlan to-r1 add port 1:1 enable ipforwarding ipv6 configure ospfv3 routerid 0.0.0.2 configure ospfv3 add vlan to-r1 area 0.0.0.0 enable ospfv3

Configuration for Router 3


The router labeled Router 3 has the following configuration:
create vlan to-r1 configure vlan to-r1 ipaddress 2001:db8:3333:5555::3/64 configure vlan to-r1 add port 1:1 enable ipforwarding ipv6 configure ospfv3 routerid 0.0.0.3 configure ospfv3 add vlan to-r1 area 0.0.0.1 enable ospfv3

ExtremeWare XOS 11.3 Concepts Guide

565

OSPFv3

566

ExtremeWare XOS 11.3 Concepts Guide

29 Border Gateway Protocol


This chapter covers the following topics:

Overview on page 568 BGP Attributes on page 568 BGP Communities on page 568 BGP Features on page 569

This chapter describes how to configure the Border Gateway Protocol (BGP), an exterior routing protocol available on the switch. For more information on BGP, refer to the following documents:

RFC 1771Border Gateway Protocol version 4 (BGP-4) RFC 1965Autonomous System Confederations for BGP RFC 1966BGP Route Reflection RFC 1997BGP Communities Attribute RFC 1745BGP/IDRP for IPOSPF Interaction RFC 2385Protection of BGP Sessions via the TCP MD5 Signature Option RFC 2439BGP Route Flap Damping RFC 2796BGP Route Reflection - An Alternative to Full Mesh IBGP RFC 2842Capabilities Advertisement with BGP-4 RFC 2858Multiprotocol Extensions for BGP-4 RFC 2918Route Refresh Capability for BGP-4 NOTE

ExtremeWare XOS supports BGP version 4 only.

NOTE
Although the CLI commands are available, this release of ExtremeWare XOS does not support the MBGP/Routerefresh features.

Licensing
BGP requires a Core license, at a minimum. The BGP process will not spawn without the required license level. The MSM-1XL is shipped with an Advanced Core license and the MSM-1 is shipped with a Core license. Other platforms can be upgraded to a Core license. See the section Software Licensing on page 33 for more information about licensing.

ExtremeWare XOS 11.3 Concepts Guide

567

Border Gateway Protocol

Overview
BGP is an exterior routing protocol that was developed for use in TCP/IP networks. The primary function of BGP is to allow different autonomous systems (ASs) to exchange network reachability information. An AS is a set of routers that are under a single technical administration. This set of routers uses a different routing protocol, for example Open Shortest Path First (OSPF), for intra-AS routing. One or more routers in the AS are configured to be border routers, exchanging information with other border routers (in different ASs) on behalf of all of the intra-routers. BGP can be used as an exterior gateway protocol (referred to as EBGP), or it can be used within an AS as an interior gateway protocol (referred to as IBGP).

BGP Attributes
The following BGP attributes are supported by the switch:

OriginDefines the origin of the route. Possible values are Interior Gateway Protocol (IGP), Exterior Gateway Protocol (EGP), and incomplete. AS_PathThe list of ASs that are traversed for this route. Next_hopThe IP address of the next hop BGP router to reach the destination listed in the NLRI field. Multi_Exit_DiscriminatorUsed to select a particular border router in another AS when multiple border routers exist. Local_PreferenceUsed to advertise this routers degree of preference to other routers within the AS. Atomic_aggregateIndicates that the sending border router has used a route aggregate prefix in the route update. AggregatorIdentifies the BGP router AS number and IP address that performed route aggregation. CommunityIdentifies a group of destinations that share one or more common attributes. Cluster_IDSpecifies a 4-byte field used by a route reflector to recognize updates from other route reflectors in the same cluster. Originator_IDSpecifies the router ID of the originator of the route in the local AS.

BGP Communities
A BGP community is a group of BGP destinations that require common handling. ExtremeWare XOS supports the following well-known BGP community attributes:

no-export no-advertise no-export-subconfed

568

ExtremeWare XOS 11.3 Concepts Guide

BGP Features

BGP Features
This section describes the following BGP features supported by ExtremeWare XOS:

Route Reflectors on page 569 Route Confederations on page 571 Route Aggregation on page 574 Using the Loopback Interface on page 574 BGP Peer Groups on page 574 BGP Route Flap Dampening on page 575 BGP Route Selection on page 577 Route Redistribution on page 577 BGP Static Network on page 578

Route Reflectors
Another way to overcome the difficulties of creating a fully meshed AS is to use route reflectors. Route reflectors allow a single router to serve as a central routing point for the AS. A cluster is formed by the route reflector and its client routers. Peer routers that are not part of the cluster must be fully meshed according to the rules of BGP. A BGP cluster, including the route reflector and its clients, is shown in Figure 76.

Figure 76: Route reflectors


AS 100
1.1.1.1
10.0.0.1 Non-client 10.0.0.2 20.0.0.2 30.0.0.2

3.3.3.3 2.2.2.2
20.0.0.1 Client

4.4.4.4
30.0.0.1 Client

Route Reflector

Cluster
EX_042

The topology shown in Figure 76 minimizes the number of BGP peering sessions required in an AS by using route reflectors. In this example, although the BGP speakers 3.3.3.3 and 4.4.4.4 do not have a direct BGP peering session between them, these speakers still receive routes from each other indirectly through 2.2.2.2. The router 2.2.2.2 is called a route reflector and is responsible for reflecting routes between its clients. Routes

ExtremeWare XOS 11.3 Concepts Guide

569

Border Gateway Protocol received from the client 3.3.3.3 by the router 2.2.2.2 are reflected to 4.4.4.4 and vice-versa. Routes received from 1.1.1.1 are reflected to all clients. To configure router 1.1.1.1, use the following commands:
create vlan to_rr configure vlan to_rr add port 1:1 configure vlan to_rr ipaddress 10.0.0.1/24 enable ipforwarding vlan to_rr configure bgp router 1.1.1.1 configure bgp as-number 100 create bgp neighbor 10.0.0.2 remote-as 100 enable bgp enable bgp neighbor all

To configure router 2.2.2.2, the route reflector, use the following commands:
create vlan to_nc configure vlan to_nc add port 1:1 configure vlan to_nc ipaddress 10.0.0.2/24 enable ipforwarding vlan to_nc create vlan to_c1 configure vlan to_c1 add port 1:2 configure vlan to_c1 ipaddress 20.0.0.2/24 enable ipforwarding vlan to_c1 create vlan to_c2 configure vlan to_c2 add port 1:2 configure vlan to_c2 ipaddress 30.0.0.2/24 enable ipforwarding vlan to_c2 configure bgp router 2.2.2.2 configure bgp as-number 100 create bgp neighbor 10.0.0.1 remote-as 100 create bgp neighbor 20.0.0.1 remote-as 100 create bgp neighbor 30.0.0.1 remote-as 100 configure bgp neighbor 20.0.0.1 route-reflector-client configure bgp neighbor 30.0.0.1 route-reflector-client enable bgp neighbor all enable bgp

To configure router 3.3.3.3, use the following commands:


create vlan to_rr configure vlan to_rr add port 1:1 configure vlan to_rr ipaddress 20.0.0.1/24 enable ipforwarding vlan to_rr configure bgp router 3.3.3.3 configure bgp as-number 100 create bgp neighbor 20.0.0.2 remote-as 100 enable bgp neighbor all enable bgp

To configure router 4.4.4.4, use the following commands:


create vlan to_rr

570

ExtremeWare XOS 11.3 Concepts Guide

BGP Features
configure vlan to_rr add port 1:1 configure vlan to_rr ipaddress 30.0.0.1/24 enable ipforwarding vlan to_rr configure bgp router 4.4.4.4 configure bgp as-number 100 create bgp neighbor 30.0.0.2 remote-as 100 enable bgp neighbor all enable bgp

Route Confederations
BGP requires networks to use a fully meshed router configuration. This requirement does not scale well, especially when BGP is used as an IGP. One way to reduce the size of a fully meshed AS is to divide the AS into multiple sub-ASs and to group these sub-ASs into a routing confederation. Within the confederation, each sub-AS must be fully meshed. The confederation is advertised to other networks as a single AS.

Route Confederation Example


Figure 77 shows an example of a confederation.

Figure 77: Routing confederation

AS 200
SubAS 65001 EBGP A
192.1.1.6/30 192.1.1.5/30

B
192.1.1.22/30

192.1.1.9/30

192.1.1.17/30

IBGP
192.1.1.18/30 192.1.1.21/30

EBGP

EBGP E

192.1.1.13/30

192.1.1.14/30

IBGP SubAS 65002

192.1.1.10/30

EX_043

In this example, AS 200 has five BGP speakers. Without a confederation, BGP would require that the routes in AS 200 be fully meshed. Using the confederation, AS 200 is split into two sub-ASs: AS65001 and AS65002. Each sub-AS is fully meshed, and IBGP is running among its members. EBGP is used between sub-AS 65001 and sub-AS 65002. Router B and router D are EBGP peers. EBGP is also used between the confederation and outside ASs.

ExtremeWare XOS 11.3 Concepts Guide

571

Border Gateway Protocol To configure router A, use the following commands:


create vlan ab configure vlan ab add port 1 configure vlan ab ipaddress 192.1.1.6/30 enable ipforwarding vlan ab configure ospf add vlan ab area 0.0.0.0 create vlan ac configure vlan ac add port 2 configure vlan ac ipaddress 192.1.1.17/30 enable ipforwarding vlan ac configure ospf add vlan ac area 0.0.0.0 enable ospf configure bgp as-number 65001 configure bgp routerid 192.1.1.17 configure bgp confederation-id 200 enable bgp create bgp neighbor 192.1.1.5 remote-AS-number 65001 create bgp neighbor 192.1.1.18 remote-AS-number 65001 enable bgp neighbor all

To configure router B, use the following commands:


create vlan ba configure vlan ba add port 1 configure vlan ba ipaddress 192.1.1.5/30 enable ipforwarding vlan ba configure ospf add vlan ba area 0.0.0.0 create vlan bc configure vlan bc add port 2 configure vlan bc ipaddress 192.1.1.22/30 enable ipforwarding vlan bc configure ospf add vlan bc area 0.0.0.0 create vlan bd configure vlan bd add port 3 configure vlan bd ipaddress 192.1.1.9/30 enable ipforwarding vlan bd configure ospf add vlan bd area 0.0.0.0 enable ospf configure bgp as-number 65001 configure bgp routerid 192.1.1.22 configure bgp confederation-id 200 enable bgp create bgp neighbor 192.1.1.6 remote-AS-number 65001 create bgp neighbor 192.1.1.21 remote-AS-number 65001 create bgp neighbor 192.1.1.10 remote-AS-number 65002 configure bgp add confederation-peer sub-AS-number 65002 enable bgp neighbor all

572

ExtremeWare XOS 11.3 Concepts Guide

BGP Features To configure router C, use the following commands:


create vlan ca configure vlan ca add port 1 configure vlan ca ipaddress 192.1.1.18/30 enable ipforwarding vlan ca configure ospf add vlan ca area 0.0.0.0 create vlan cb configure vlan cb add port 2 configure vlan cb ipaddress 192.1.1.21/30 enable ipforwarding vlan cb configure ospf add vlan cb area 0.0.0.0 enable ospf configure bgp as-number 65001 configure bgp routerid 192.1.1.21 configure bgp confederation-id 200 enable bgp create bgp neighbor 192.1.1.22 remote-AS-number 65001 create bgp neighbor 192.1.1.17 remote-AS-number 65001 enable bgp neighbor all

To configure router D, use the following commands:


create vlan db configure vlan db add port 1 configure vlan db ipaddress 192.1.1.10/30 enable ipforwarding vlan db configure ospf add vlan db area 0.0.0.0 create vlan de configure vlan de add port 2 configure vlan de ipaddress 192.1.1.14/30 enable ipforwarding vlan de configure ospf add vlan de area 0.0.0.0 enable ospf configure bgp as-number 65002 configure bgp routerid 192.1.1.14 configure bgp confederation-id 200 enable bgp create bgp neighbor 192.1.1.9 remote-AS-number 65001 create bgp neighbor 192.1.1.13 remote-AS-number 65002 configure bgp add confederation-peer sub-AS-number 65001 enable bgp neighbor all

To configure router E, use the following commands:


create vlan ed configure vlan ed add port 1 configure vlan ed ipaddress 192.1.1.13/30 enable ipforwarding vlan ed configure ospf add vlan ed area 0.0.0.0 enable ospf

ExtremeWare XOS 11.3 Concepts Guide

573

Border Gateway Protocol

configure bgp as-number 65002 configure bgp routerid 192.1.1.13 configure bgp confederation-id 200 enable bgp create bgp neighbor 192.1.1.14 remote-AS-number 65002 enable bgp neighbor 192.1.1.14

Route Aggregation
Route aggregation is the process of combining the characteristics of several routes so that they are advertised as a single route. Aggregation reduces the amount of information that a BGP speaker must store and exchange with other BGP speakers. Reducing the information that is stored and exchanged also reduces the size of the routing table.

Using Route Aggregation


To use BGP route aggregation: 1 Enable aggregation using the following command:
enable bgp aggregation

2 Create an aggregate route using the following command:


configure bgp add aggregate-address {address-family [ipv4-unicast | ipv4multicast]} <ipaddress> {as-match | as-set} {summary-only} {advertise-policy <policy>} {attribute-policy <policy>}

Using the Loopback Interface


If you are using BGP as your IGP, you may decide to advertise the interface as available, regardless of the status of any particular interface. The loopback interface can also be used for EBGP multihop. Using the loopback interface eliminates multiple, unnecessary route changes.

BGP Peer Groups


You can use BGP peer groups to group together up to 512 BGP neighbors. All neighbors within the peer group inherit the parameters of the BGP peer group. The following mandatory parameters are shared by all neighbors in a peer group:

remote AS source-interface route-policy send-community next-hop-self

Each BGP peer group is assigned a unique name when it is created. To create or delete peer groups, use the following command:
create bgp peer-group <peer-group-name> delete bgp peer-group <peer-group-name>

574

ExtremeWare XOS 11.3 Concepts Guide

BGP Features Changes made to the parameters of a peer group are applied to all neighbors in the peer group. Modifying the following parameters will automatically disable and enable the neighbors before changes take effect:

remote-as timer source-interface soft-in-reset password

Adding Neighbors to a BGP Peer Group


To create a new neighbor and add it to a BGP peer group, use the following command:
create bgp neighbor <remoteaddr> peer-group <peer-group-name> {multi-hop}

The new neighbor is created as part of the peer group and inherits all of the existing parameters of the peer group. The peer group must have remote AS configured. To add an existing neighbor to a peer group, use the following command:
configure bgp neighbor [all | <remoteaddr>] peer-group [<peer-group-name> | none] {acquire-all}

If you do not specify the acquire-all option, only the mandatory parameters are inherited from the peer group. If you specify the acquire-all option, all of the parameters of the peer group are inherited. This command disables the neighbor before adding it to the peer group. To remove a neighbor from a peer group, use the peer-group none option. When you remove a neighbor from a peer group, the neighbor retains the parameter settings of the group. The parameter values are not reset to those the neighbor had before it inherited the peer group values.

BGP Route Flap Dampening


Route flap dampening is a BGP feature designed to minimize the propagation of flapping routes across an internetwork. A route is considered to be flapping when it is repeatedly available, then unavailable, then available, then unavailable, and so on. When a route becomes unavailable, a withdrawal message is sent to other connected routers, which in turn propagate the withdrawal message to other routers. As the route becomes available again, an advertisement message is sent and propagated throughout the network. As a route repeatedly changes from available to unavailable, large numbers of messages propagate throughout the network. This is a problem in an internetwork connected to the Internet because a route flap in the Internet backbone usually involves many routes.

Minimizing the Route Flap


The route flap dampening feature minimizes the flapping problem as follows. Suppose that the route to network 172.25.0.0 flaps. The router (in which route dampening is enabled) assigns network 172.25.0.0 a

ExtremeWare XOS 11.3 Concepts Guide

575

Border Gateway Protocol penalty of 1000 and moves it to a history state in which the penalty value is monitored. The router continues to advertise the status of the route to neighbors. The penalties are cumulative. When the route flaps so often that the penalty exceeds a configurable suppress limit, the router stops advertising the route to network 172.25.0.0, regardless of how many times it flaps. Thus, the route is dampened. The penalty placed on network 172.25.0.0 is decayed until the reuse limit is reached, when the route is once again advertised. At half of the reuse limit, the dampening information for the route to network 172.25.0.0 is removed. The penalty is decayed by reducing the penalty value by one-half at the end of a configurable time period, called the half-life. Routes that flap many times may reach a maximum penalty level, or ceiling, after which no additional penalty is added. The ceiling value is not directly configurable, but the configuration parameter used in practice is the maximum route suppression time. No matter how often a route has flapped, once it stops flapping, it will again be advertised after the maximum route suppression time.

Configuring Route Flap Dampening


Using a routing policy, you enable BGP route flap dampening per BGP peer session, for a BGP peer group, or for a set of routes. To enable route flap dampening over BGP peer sessions, use the following command:
configure bgp neighbor [all | <remoteaddr>] {address-family [ipv4-unicast | ipv4multicast]} dampening {{half-life <half-life-minutes> {reuse-limit <reuse-limitnumber> suppress-limit <suppress-limit-number> max-suppress <max-suppress-minutes>} | policy-filter [<policy-name> | none]}

To enable route flap dampening for a BGP peer group, use the following command:
configure bgp peer-group <peer-group-name> {address-family [ipv4-unicast | ipv4multicast]} dampening {{half-life <half-life-minutes> {reuse-limit <reuse-limitnumber> supress-limit <suppress-limit-number> max-suppress <max-suppress-minutes>}} | policy-filter [<policy-name> | none]}

You can supply the dampening parameters directly through the command line interface (CLI) command, or use the command to associate a policy that contains the desired parameters.

Disabling Route Flap Dampening


To disable route flap dampening for a BGP neighbor (disabling the dampening also deletes all the configured dampening parameters), use the following command:
configure bgp neighbor [<remoteaddr> | all] {address-family [ipv4-unicast | ipv4multicast]} no-dampening

To disable route flap dampening for a BGP peer group, use the following command:
configure bgp peer-group <peer-group-name> no-dampening

Viewing the Route Flap Dampening Configuration


To view the configured values of the route flap dampening parameters for a BGP neighbor, use the following command:
show bgp [neighbor {detail} | {neighbor} <remoteaddr>]

576

ExtremeWare XOS 11.3 Concepts Guide

BGP Features To view the configured values of the route flap dampening parameters for a BGP peer group, use the following command:
show bgp peer-group {detail | <peer-group-name> {detail}}

To display the dampened routes, use the following command:


show bgp neighbor <remoteaddr> {address-family [ipv4-unicast | ipv4-multicast]} flapstatistics {detail} [all | as-path <path-expression> | community [no-advertise | noexport | no-export-subconfed | number <community_num> | <AS_Num>:<Num> ] | network [any / <netMaskLen> | <networkPrefixFilter>] {exact} ]

BGP Route Selection


BGP selects routes based on the following precedence (from highest to lowest):

higher weight higher local preference shortest length (shortest AS path) lowest origin code lowest Multi Exit Discriminator (MED) route from external peer lowest cost to next hop lowest routerID

Stripping Out Private AS Numbers from Route Updates


Private AS numbers are AS numbers in the range 64512 through 65534. You can remove private AS numbers from the AS path attribute in updates that are sent to external BGP (EBGP) neighbors. Possible reasons for using private AS numbers include:

The remote AS does not have officially allocated AS numbers. You want to conserve AS numbers if you are multihomed to the local AS.

Private AS numbers should not be advertised on the Internet. Private AS numbers can be used only locally within an administrative domain. Therefore, when routes are advertised out to the Internet, the routes can be stripped out from the AS paths of the advertised routes using this feature. To configure private AS numbers to be removed from updates, use the following command:
enable bgp neighbor [<remoteaddr> | all] remove-private-AS-numbers

To disable this feature, use the following command:


disable bgp neighbor [<remoteaddr> | all] remove-private-AS-numbers

Route Redistribution
BGP, OSPF, and RIP can be enabled simultaneously on the switch. Route redistribution allows the switch to exchange routes, including static and direct routes, between any two routing protocols.

ExtremeWare XOS 11.3 Concepts Guide

577

Border Gateway Protocol Exporting routes from OSPF to BGP and from BGP to OSPF are discrete configuration functions. To run OSPF and BGP simultaneously, you must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPF to BGP and the routes to export from BGP to OSPF.

Configuring Route Redistribution


Exporting routes between any two routing protocols are discrete configuration functions. For example, you must configure the switch to export routes from OSPF to BGP; and, if desired, you must configure the switch to export routes from BGP to OSPF. You must first configure both protocols and then verify the independent operation of each. Then you can configure the routes to export from OSPF to BGP and the routes to export from BGP to OSPF. You can use route maps to associate BGP attributes including Community, NextHop, MED, Origin, and Local Preference with the routes. Route maps can also be used to filter out exported routes. To enable or disable the exporting of OSPF, RIP, static, and direct (interface) routes to BGP, use the following commands:
enable bgp export [direct | ospf | ospf-extern1 | ospf-extern2 | ospf-inter | ospfintra | rip | static] {address-family [ipv4-unicast | ipv4-multicast]} {export-policy <policy-name>} disable bgp export [direct | ospf | ospf-extern1 | ospf-extern2 | ospf-inter | ospfintra | rip | static] {address-family [ipv4-unicast | ipv4-multicast]}

Using the export command to redistribute routes complements the redistribution of routes using the configure bgp add network command. The configure bgp add network command adds the route to BGP only if the route is present in the routing table. The enable bgp export command redistributes the specified routes from the routing table to BGP. If you use both commands to redistribute routes, the routes redistributed using the network command take precedence over routes redistributed using the export command.

BGP Static Network


ExtremeWare XOS BGP allows users to add static networks in BGP, which will be redistributed (advertised) into the BGP domain if there is a corresponding active route in the IP routing table. Users can associate a policy with the static BGP network to change or to set the route attributes before the route is advertised to the BGP neighbors. Use the following command to create a static BGP network:
configure bgp add network {address-family [ipv4-unicast | ipv4-multicast]} <ipaddr>/ <mask_len> {network-policy <policy>}

Use the following command to delete a static BGP network


configure bgp delete network {address-family [ipv4-unicast | ipv4-multicast]} [all | <ipaddress/mask length>]

578

ExtremeWare XOS 11.3 Concepts Guide

30 IP Multicast Routing
This chapter covers the following topics:

Overview on page 579 Configuring IP Multicast Routing on page 583 Configuration Examples on page 583

For more information on IP multicasting, refer to the following publications:


RFC 1112Host Extension for IP Multicasting RFC 2236Internet Group Management Protocol, Version 2 PIM-DM Version 2draft_ietf_pim_v2_dm_03 RFC 2362Protocol-Independent Multicast - Sparse Mode (PIM-SM): Protocol Specification

The following URL points to the website for the IETF PIM Working Group: http://www.ietf.org/html.charters/pim-charter.html

Overview
IP multicast routing is a function that allows a single IP host to send a packet to a group of IP hosts. This group of hosts can include devices that reside on or outside the local network and within or across a routing domain. IP multicast routing consists of the following functions:

A router that can forward IP multicast packets A router-to-router multicast routing protocol (for example, Protocol Independent Multicast (PIM)) A method for the IP host to communicate its multicast group membership to a router (for example, Internet Group Management Protocol (IGMP)) NOTE

You should configure IP unicast routing before you configure IP multicast routing.

PIM Overview
The switch supports both dense mode and sparse mode operation. You can configure dense mode or sparse mode on a per-interface basis. After they are enabled, some interfaces can run dense mode, while others run sparse mode.

ExtremeWare XOS 11.3 Concepts Guide

579

IP Multicast Routing

Licensing
To use the complete PIM functionality, you must have at least a Core license installed on your switch. The BlackDiamond 10K ships with a Core, or Advanced Core license. Other platforms can be upgraded to a Core license. See the section Software Licensing on page 33 for more information about licensing. A subset of PIM, called PIM Edge Mode, is available with an Advanced Edge license.

PIM Edge Mode


PIM Edge Mode is a subset of PIM available on platforms with an Advanced Edge license. There are only three restrictions on PIM Edge Mode:

The switch will not act as a candidate RP. The switch will not act as a candidate BSR. At most, two Active PIM-SM interfaces are permitted. There is no restriction on the number of Passive interfaces (within the limit of the maximum IP interfaces). Only PIM Sparse Mode (PIM-SM) is supported in this mode.

Active PIM interfaces can have other PIM enabled routers on them. Passive interfaces should only have host sourcing or receiving multicast traffic.

PIM Dense Mode


Protocol-Independent Multicast - Dense Mode (PIM-DM) is a multicast routing protocol. PIM-DM is a broadcast and prune protocol, which allows you to prune and graft multicast routes. PIM-DM routers perform reverse path multicasting (RPM). However, instead of exchanging its own unicast route tables for the RPM algorithm, PIM-DM uses the existing unicast routing table for the reverse path. As a result, PIM-DM requires less system memory.

PIM Sparse Mode


Unlike PIM-DM, Protocol-Independent Multicast - Sparse Mode (PIM-SM) is an explicit join and prune protocol, and it supports shared trees as well as shortest path trees (SPTs). The routers must explicitly join the group(s) in which they are interested in becoming a member, which is beneficial for large networks that have group members that are sparsely distributed. Using PIM-SM, the router sends a join message to the rendezvous point (RP). The RP is a central multicast router that is responsible for receiving and distributing the initial multicast packets. You can configure a dynamic or static RP. When a router has a multicast packet to distribute, it encapsulates the packet in a unicast message and sends it to the RP. The RP decapsulates the multicast packet and distributes it among all member routers. When a router determines that the multicast rate has exceeded a configured threshold, that router can send an explicit join to the originating router. When this occurs, the receiving router gets the multicast directly from the sending router and bypasses the RP.

580

ExtremeWare XOS 11.3 Concepts Guide

Overview

NOTE
You can run either PIM-DM or PIM-SM per virtual LAN (VLAN).

PIM Mode Interoperation


An Extreme Networks switch can function as a PIM multicast border router (PMBR). A PMBR integrates PIM-SM and PIM-DM traffic. When forwarding PIM-DM traffic into a PIM-SM network, the PMBR acts as a virtual first hop and encapsulates the initial traffic to RP. The PMBR forwards PIM-DM multicast packets to the RP, which, in turn, forwards the packets to those routers that have joined the multicast group. The PMBR also forwards PIM-SM traffic to a PIM-DM network, based on the (*.*.RP) entry. The PMBR sends a (*.*.RP) join message to the RP, and the PMBR forwards traffic from the RP into the PIM-DM network. No commands are required to enable PIM mode interoperation. PIM mode interoperation is automatically enabled when a dense mode interface and a sparse mode interface are enabled on the same switch.

IGMP Overview
IGMP is a protocol used by an IP host to register its IP multicast group membership with a router. Periodically, the router queries the multicast group to see if the group is still in use. If the group is still active, a single IP host responds to the query, and group registration is maintained. IGMPv2 is enabled by default on the switch, and beginning with release 11.2, ExtremeWare XOS supports IGMPv3. However, the switch can be configured to disable the generation of periodic IGMP query packets. IGMP should be enabled when the switch is configured to perform IP unicast or IP multicast routing. IGMPv3, specified in RFC 3376, adds support for source filtering. Source filtering is the ability for a system to report interest in receiving packets only from specific source addresses, (filter mode include), or from all sources except for specific addresses, (filter mode exclude). IGMPv3 is designed to be interoperable with IGMPv1 and IGMPv2.

IGMP Snooping
IGMP snooping is a Layer 2 function of the switch; it does not require multicast routing to be enabled. In IGMP snooping, the Layer 2 switch keeps track of IGMP reports and only forwards multicast traffic to that part of the local network that requires it. IGMP snooping optimizes the use of network bandwidth and prevents multicast traffic from being flooded to parts of the local network that do not need it. IGMP snooping is enabled by default on the switch. If IGMP snooping is disabled, all IGMP and IP multicast traffic floods within a given VLAN. IGMP snooping expects at least one device on every VLAN to periodically generate IGMP query messages. When a port sends an IGMP leave message, the switch removes the IGMP snooping entry after 1000 milliseconds (the leave time is configurable, ranging from 0 to 10000 ms). The switch sends a query to

ExtremeWare XOS 11.3 Concepts Guide

581

IP Multicast Routing determine which ports want to remain in the multicast group. If other members of the VLAN want to remain in the multicast group, the router ignores the leave message, but the port that requests removal is removed from the IGMP snooping table. If the last port within a VLAN sends an IGMP leave message and the router does not receive any responses to the query, then the router immediately removes the VLAN from the multicast group.

Static IGMP
To receive multicast traffic, a host must explicitly join a multicast group by sending an IGMP report; then, the traffic is forwarded to that host. In some situations, you would like multicast traffic to be forwarded to a port where a multicast-enabled host is not available (for example, when you test multicast configurations). Static IGMP emulates a host or router attached to a switch port, so that multicast traffic is forwarded to that port, and the switch will send a proxy join for all the statically configured IGMP groups when an IGMP query is received. You can emulate a host to forward a particular multicast group to a port; and you may emulate a router to forward all multicast groups to a port. Static IGMP is only available with IGMPv2. Use the following command to emulate a host on a port:
configure igmp snooping {vlan} <vlanname> ports <portlist> add static group <ip address>

To emulate a multicast router on a port, use the following command:


configure igmp snooping {vlan} <vlanname> ports <portlist> add static router

To remove these entries, use the corresponding command:


configure igmp snooping {vlan} <vlanname> ports <portlist> delete static group [<ip_address> | all] configure igmp snooping vlan <vlanname> ports <portlist> delete static router

To display the IGMP snooping static groups, use the following command:
show igmp snooping vlan <name> static [group | router]

IGMP Snooping Filters


IGMP snooping filters allow you to configure a policy file on a port to allow or deny IGMP report and leave packets coming into the port. (For details on creating policy files, see Policy Manager on page 257.) IGMP snooping filters is available with IGMPv2 and IGMPv3. For the policies used as IGMP snooping filters, all the entries should be IP address type entries, and the IP address of each entry must be in the class-D multicast address space but should not be in the multicast control subnet range (224.0.0.x/24). After you create a policy file, use the following command to associate the policy file and filter a set of ports:
configure igmp snooping vlan <vlanname> ports <portlist> filter [<policy> | none]

To remove the filter, use the none option.

582

ExtremeWare XOS 11.3 Concepts Guide

Configuring IP Multicast Routing To display the IGMP snooping filters, use the following command:
show igmp snooping {vlan} <name> filter

Configuring IP Multicast Routing


To configure IP multicast routing: 1 Configure the system for IP unicast routing. 2 Enable multicast routing on the interface using the following command:
enable ipmcforwarding {vlan <name>}

3 Enable PIM on all IP multicast routing interfaces using the following command:
configure pim add vlan [<vlan_name> | all] {dense | sparse} {passive}

4 Enable PIM on the router using the following command:


enable pim

Configuration Examples
Figure 78 and Figure 79 are used in Chapter 25 to describe the Open Shortest Path First (OSPF) configuration on a switch. See Chapter 25 for more information about configuring OSPF.

ExtremeWare XOS 11.3 Concepts Guide

583

IP Multicast Routing

PIM-DM Configuration Example


In Figure 78, the system labeled IR 1 is configured for IP multicast routing, using PIM-DM.

Figure 78: IP multicast routing using PIM-DM configuration example

Area 0

IR 2
10.0.3.2

10.0.1.1

10.0.1.2 10.0.2.2
_1 0_ 0_ 2

IR 1

3 0_ 0_ _1 HQ

Headquarters

ABR 2

10.0.3.1

ABR 1

HQ

10.0.2.1

161.48.2.2

Los Angeles
LA _1
26

160.26.25.1

160.26.26.1
_2

161.48.2.1
_4 8_

61

160.26.26.2

Ch

160.26.25.2

Area 5

i_1

Virtual link

6_

60

Chicago

Area 6 (stub)
EX_040

584

ExtremeWare XOS 11.3 Concepts Guide

Configuration Examples The router labeled IR1 has the following configuration:
configure vlan HQ_10_0_1 ipaddress 10.0.1.2 255.255.255.0 configure vlan HQ_10_0_2 ipaddress 10.0.2.2 255.255.255.0 configure ospf add vlan all area 0.0.0.0 enable ipforwarding enable ospf enable ipmcforwarding configure pim add vlan all dense enable pim

PIM-SM Configuration Example


In Figure 79, the system labeled ABR1 is configured for IP multicast routing using PIM-SM.

Figure 79: IP multicast routing using PIM-SM configuration example

Area 0

IR 2
10.0.3.2

10.0.1.1

10.0.1.2 10.0.2.2
0_ 0_ 2

IR 1
HQ_10_10_4

HQ

Headquarters

ABR 2

10.0.3.1

ABR 1

HQ

10.0.2.1

_1

160.26.25.1

160.26.26.1
60 _2 6

_2

_1 0_ 0_ 3

Rendezvous point
161.48.2.2

Los Angeles
LA _1 61 _4 8_

161.48.2.1

160.26.26.2

Ch

160.26.25.2

Area 5

i_1

Virtual link

Chicago

Area 6 (stub)
EX_062

The router labeled ABR1 has the following configuration:


configure vlan HQ_10_0_2 ipaddress 10.0.2.1 255.255.255.0 configure vlan HQ_10_0_3 ipaddress 10.0.3.1 255.255.255.0

ExtremeWare XOS 11.3 Concepts Guide

585

IP Multicast Routing
configure vlan LA_161_48_2 ipaddress 161.48.2.2 255.255.255.0 configure vlan CHI_160_26_26 ipaddress 160.26.26.1 255.255.255.0 configure ospf add vlan all area 0.0.0.0 enable ipforwarding enable ipmcforwarding configure pim add vlan all sparse tftp TFTP_SERV -g -r rp_list.pol configure pim crp HQ_10_0_3 rp_list 30 configure pim cbsr HQ_10_0_3 30

The policy file, rp_list.pol, contains the list of multicast group addresses serviced by this RP. This set of group addresses are advertised as candidate RPs. Each router then elects the common RP for a group address based on a common algorithm. This group to RP mapping should be consistent on all routers. The following is a policy file which will configure the CRP for the address ranges 239.0.0.0/24 and 232.144.27.0:
entry extreme1 { if match any { } then { nlri 239.0.0.0/24 ; nlri 232.144.27.0 ; } }

586

ExtremeWare XOS 11.3 Concepts Guide

31 IPv6 Multicast Routing


This chapter covers the following topics:

Overview on page 587 MLD Overview on page 587 MLD Snooping on page 587 Static MLD on page 588

Overview
IPv6 multicast routing is a function that allows a single IPv6 host to send a packet to a group of IPv6 hosts. This group of hosts can include devices that reside on or outside the local network, or within or across a routing domain. IPv6 multicast routing consists of the following functions:

A router that can forward IPv6 multicast packets A router-to-router multicast protocol [for example, Protocol Independent Multicast (PIM)] A method for the IPv6 host to communicate its multicast group membership to a router [for example, Multicast Listener Discovery (MLD)] NOTE

In the current release of ExtremeWare XOS (11.3), IPv6 multicast packets are flooded to VLANs that receive the traffic.

MLD Overview
MLD is a protocol used by an IPv6 host to register its IP multicast group membership with a router. Periodically, the router queries the multicast group to see if the group is still in use. If the group is still active, a single IP host responds to the query, and group registration is maintained. MLD is the IPv6 equivalent to IGMP. MLDv1 is equivalent to IGMPv2, and MLDv2 is equivalent to IGMPv3. MLDv1 is currently supported on the switch.

MLD Snooping
MLD snooping is a Layer 2 function of the switch; it does not require multicast routing to be enabled. In MLD snooping, the Layer 2 switch keeps track of MLD reports and only forwards multicast traffic to that part of the local network that requires it. MLD snooping optimizes the use of network bandwidth and prevents multicast traffic from being flooded to parts of the local network that do not need it.

ExtremeWare XOS 11.3 Concepts Guide

587

IPv6 Multicast Routing MLD snooping is enabled by default on the switch. If MLD snooping is disabled, all MLD and IP multicast traffic floods within a given VLAN. MLD snooping expects at least one device on every VLAN to periodically generate MLD query messages. When a port sends an MLD done message, the switch removes the MLD snooping entry after 1000 milliseconds (the leave time is configurable, ranging from 0 to 10000 ms). The switch sends a query to determine which ports want to remain in the multicast group. If other members of the VLAN want to remain in the multicast group, the router ignores the done message, but the port that requests removal is removed from the MLD snooping table. If the last port within a VLAN sends an MLD done message and the router does not receive any responses to the query, then the router immediately removes the VLAN from the multicast group.

Static MLD
To receive multicast traffic, a host must explicitly join a multicast group by sending an MLD report; then, the traffic is forwarded to that host. In some situations, you would like multicast traffic to be forwarded to a port where a multicast-enabled host is not available (for example, when you test multicast configurations). Static MLD emulates a host or router attached to a switch port, so that multicast traffic is forwarded to that port, and the switch will send a proxy join for all the statically configured MLD groups when an MLD query is received. You can emulate a host to forward a particular multicast group to a port; and you may emulate a router to forward all multicast groups to a port. Use the following command to emulate a host on a port:
configure mld snooping {vlan} <vlanname> ports <portlist> add static group <v6grpipaddress>

To emulate a multicast router on a port, use the following command:


configure mld snooping {vlan} <vlanname> ports <portlist> add static router

To remove these entries, use the corresponding command:


configure mld snooping {vlan} <vlanname> ports <portlist> delete static group [all | <v6grpipaddress>] configure mld snooping {vlan} <vlanname> ports <portlist> delete static router

To display the MLD snooping static groups, use the following command:
show mld snooping vlan <name> static [group | router]

588

ExtremeWare XOS 11.3 Concepts Guide

Appendixes

Software Upgrade and Boot Options

This appendix describes the following topics:


Downloading a New Image on page 591 Understanding Hitless UpgradeBlackDiamond 10K Switch Only on page 597 Saving Configuration Changes on page 601 Using TFTP to Upload the Configuration on page 603 Using TFTP to Download the Configuration on page 603 Synchronizing MSMsModular Switches Only on page 604 Accessing the Bootloader on page 605 Upgrading the BootROMBlackDiamond 10K Switch Only on page 606 Upgrading the BootROMSummit X450 Switch Only on page 606 Upgrading the FirmwareBlackDiamond 8800 Family of Switches Only on page 607

Downloading a New Image


The core image file contains the executable code that runs on the switch and is preinstalled at the factory. As new versions of this image are released, you should upgrade the software running on your system. Modular software packages enhance the functionality of the ExtremeWare XOS core image currently running on your switch. Modular software packages are not preinstalled at the factory. On the BlackDiamond 10K switch, you can upgrade the images without taking the switch out of service or interrupting network operation. This is known as hitless upgrade. For more information, see Understanding Hitless UpgradeBlackDiamond 10K Switch Only on page 597. This section describes the following topics:

Image Filename Prefixes on page 591 Understanding the Image Version String on page 592 Software Signatures on page 592 Selecting a Primary or a Secondary Image on page 593 Installing a Core Image on page 593 Installing a Modular Software Package on page 594 Rebooting the Switch on page 596 Rebooting the Management ModuleModular Switches Only on page 597

Image Filename Prefixes


The software image file can be a .xos file, which contains an ExtremeWare XOS core image, or a .xmod file, which contains an ExtremeWare XOS modular software package.

ExtremeWare XOS 11.3 Concepts Guide

591

Software Upgrade and Boot Options You can identify the appropriate image or module for your platform based on the filename of the image. Table 71 lists the filename prefixes for each platform:

Table 71: Filename prefixes


Platform BlackDiamond 10K BlackDiamond 8810 BlackDiamond 8806 Summit X450 Filename Prefixes bd10Kbd8800bd8800summitX450-

For example, if you have a BlackDiamond 8806 switch, download image filenames with the prefix bd8800-. For additional installation requirements see the sections, Installing a Core Image on page 593 and Installing a Modular Software Package on page 594.

Understanding the Image Version String


The image version string contains build information for each version of ExtremeWare XOS. You can use either the show version or show switch command to display the ExtremeWare XOS version running on your switch. Depending on the command line interface (CLI) command, the output is structured as follows:

show version

ExtremeWare XOS Version <major>.<minor>.<patch>.<build> For example: ExtremeWare XOS version 10.1.2.16

show switch

<major>.<minor>.<patch>.<build> For example: 10.1.2.16 Table 72 describes the image version fields.

Table 72: Image version fields


Field major minor patch build Description Specifies the ExtremeWare XOS major version number. Specifies the ExtremeWare XOS minor version number. Identifies a specific patch release. Specifies the ExtremeWare XOS build number. This value is reset to zero for each new major and minor release.

Software Signatures
Each ExtremeWare XOS image contains a unique signature. The BootROM checks for signature compatibility and denies an incompatible software upgrade. In addition, the software checks both the installed BootROM and software and also denies an incompatible upgrade.

592

ExtremeWare XOS 11.3 Concepts Guide

Downloading a New Image

Selecting a Primary or a Secondary Image


A switch can store up to two core images: a primary and a secondary. When downloading a new image, you select which partition (primary or secondary) to install the new image. If you do not specify a partition, the software image is downloaded and installed into the current (active) partition. If you want to install the software image to the alternate partition, you must specify that partition before downloading the image. To view your current (active) partition, use the following command:
show switch

Output from this command includes the selected and booted images and if they are in the primary or secondary partition. If two MSMs are installed in a modular switch, the downloaded image is saved to the same location on each one. You can select which image the switch will load on the next reboot by using the following command:
use image {partition} <partition> {msm <slotid>}

Installing a Core Image


Depending on the switch, you can upgrade the core image by using a download procedure from a Trivial File Transfer Protocol (TFTP) server on the network or an external compact flash memory card installed in the external compact flash slot of the Management Switch Fabric Module (MSM). Downloading a new image involves the following steps:

Loading the new image onto a TFTP server on your network (if you are using TFTP). Loading the new image onto an external compact flash memory card (if you are using the external compact flash slot). This method is available only on modular switches. Use a PC with appropriate hardware such as a compact flash reader/writer and follow the manufacturers instructions to access the compact flash card and place the image onto the card. For more information about installing the external compact flash memory card into the external compact flash slot of the MSM, please refer to the Extreme Networks Consolidated XOS Hardware Installation Guide.

Selecting the partition to use when downloading an image. For more information, see Selecting a Primary or a Secondary Image on page 593. Downloading the new image to the switch using the following command:
download image [[<hostname> | <ipaddress>] <filename> {{vr} <vrname>} | memorycard <filename>] {<partition>} {msm <slotid>}

Before the download begins, the switch asks if you want to install the image immediately after the download is finished. If you install the image to the active partition, you must reboot the switch. If you install the image to the inactive partition, you do not need to reboot the switch. Enter y to install the image after download. Enter n to install the image at a later time. If you download and install the software image on the active partition, the switch automatically reboots after the download and installation is completed. The following message appears when downloading and installing on the active partition:
Image will be installed to the active partition, a reboot required. Do you want to continue? (y or n)

ExtremeWare XOS 11.3 Concepts Guide

593

Software Upgrade and Boot Options Enter y to continue the installation and reboot the switch. Enter n to cancel. If you install the image at a later time, the image is still downloaded and saved to the switch, but you must use the following command to install the software:
install image <fname> {<partition>} {msm <slotid>} {reboot}

NOTE
Unlike ExtremeWare, the download image command in ExtremeWare XOS causes the switch to use the newly downloaded software image during the next switch reboot. To modify or reset the software image used during a switch reboot, issue the use image command.

Installing a Modular Software Package


In addition to the functionality available in the ExtremeWare XOS core image, you can add functionality to your switch by installing modular software packages. Modular software packages are contained in files named with the file extension.xmod, while the core images use the file extension.xos. Modular software packages are built at the same time as core images and are designed to work in concert with the core image, so the version number of a modular software package must match the version number of the core image that it will be running with. For example, the modular software package for Secure Shell (SSH) named as follows:
bd10K-11.2.0.18-ssh.xmod

can run only with the core image named:


bd10K-11.2.0.18.xos

You can install a modular software package on the active partition or on the inactive partition. You would install on the active partition if you want to add the package functionality to the currently running core image without having to reboot the switch. You would install on the inactive partition if you want the functionality available after a switch reboot. To install the package, you use the same process that you use to install a new core image. Follow the process described in the earlier section Installing a Core Image. On the BlackDiamond 10K switch, you can use hitless upgrade to install the package. See Understanding Hitless Upgrade BlackDiamond 10K Switch Only on page 597 for more information. You activate the installed modular software package either by rebooting the switch or by issuing the following command:
run update

You can uninstall packages by issuing the following command:


uninstall image <fname> <partition> {msm <slotid>} {reboot}

NOTE
Do not terminate a process that was installed since the last reboot unless you have saved your configuration. If you have installed a software module and you terminate the newly installed process without saving your configuration, your module may not be loaded when you attempt to restart the process with the start process command.

The rest of this section describes the following topics:

Guidelines for Activating SSL

594

ExtremeWare XOS 11.3 Concepts Guide

Downloading a New Image

Upgrading a Modular Software Package

Guidelines for Activating SSL


Whether you are currently running SSH or downloading the SSH software module for the first time, you must complete the following steps to activate the Secure Socket Layer (SSL) functionality that is packaged with the SSH module. Before you can configure SSL on the switch, do the following:

Download and install the SSH software module on the active partition Activate the SSH software module Gracefully terminate and re-start the thttpd process running on the switch

The following is an example of activating SSL on the switch:


download image 10.10.10.2 bd10K-11.2.0.18-ssh.xmod run update restart process thttpd

For more information about SSH and SSL, see Chapter 16, Security.

Upgrading a Modular Software Package


When Extreme Networks introduces a new core software image, a new modular software package is also available. If you have a software module installed and upgrade to a new core image, you need to upgrade to the corresponding modular software package. Two methods are available to upgrade an existing modular software package on your switch. Regardless of which method you choose, you must terminate and restart the processes associated with the software module. Method One. 1 Terminate the processes associated with the software module using the following command:
terminate process <name> [forceful | graceful] {msm <slot>}

2 Download the software module from your TFTP server or external compact flash memory card using the following command:
download image [[<hostname> | <ipaddress>] <filename> {{vr} <vrname>} | memorycard <filename>] {<partition>} {msm <slotid>}

3 Activate the installed modular package, if installed on the active partition, using the following command:
run update

4 Restart the processes associated with the software module using the following command:
start process <name> {msm <slot>}

ExtremeWare XOS 11.3 Concepts Guide

595

Software Upgrade and Boot Options Method Two. 1 Download the software module from your TFTP server or external compact flash memory card using the following command:
download image [[<hostname> | <ipaddress>] <filename> {{vr} <vrname>} | memorycard <filename>] {<partition>} {msm <slotid>}

2 Activate the installed modular package, if installed on the active partition, using the following command:
run update

3 Terminate and restart the processes associated with the software module using the following command: restart process [class <cname> | <name> {msm <slot>}] Examples. The following examples upgrade the SSH module on the active partition and assume that you have:

Upgraded the switch to a new core image (see Installing a Core Image on page 593 for more information) Downloaded the corresponding modular software package to your TFTP server. On a modular switch, you can download the modular software package to an external compact flash memory card (see Downloading a New Image on page 591 for more information)

The first example uses the terminate process and start process commands to terminate and restart the processes associated with the software module that you are updating:
terminate process exsshd graceful download image 10.10.10.2 bd10K-11.3.0.10-ssh.xmod run update start process exsshd

The second example uses the restart process command to terminate and restart the processes associated with the software module that you are updating:
download image 10.10.10.2 bd10K-11.3.0.10-ssh.xmod run update restart process exsshd

Rebooting the Switch


To reboot the switch, use the following command:
reboot {time <month> <day> <year> <hour> <min> <sec>} {cancel} {warm} {msm <slot_id>}

Use this command to schedule a time to reboot the switch or to reboot the switch immediately. To schedule a time to reboot the switch, use the following command:
reboot time <date> <time>

Where date is the date and time is the time (using a 24-hour clock format) when the switch will be rebooted. The values use the following format:
mm dd yyyy hh mm ss

596

ExtremeWare XOS 11.3 Concepts Guide

Understanding Hitless UpgradeBlackDiamond 10K Switch Only

NOTE
When you configure a timed reboot of the switch, use the show switch command to see the scheduled time.

To reboot the switch immediately, use the following command:


reboot

If you do not specify a reboot time, the reboot occurs immediately following the command, and any previously schedule reboots are cancelled. To cancel a previously scheduled reboot, use the cancel option.

Rebooting the Management ModuleModular Switches Only


To reboot a management module in a specific slot, rather than rebooting the switch, use the following command:
reboot {time <month> <day> <year> <hour> <min> <sec>} {cancel} {warm} {msm <slot_id>}

with the additional options available:


slot_id Specifies the slot where the module is installed msm-aSpecifies the MSM module installed in slot A msm-bSpecifies the MSM module installed in slot B

NOTE
When you configure a timed reboot of an MSM, use the show switch command to see the scheduled time.

Understanding Hitless UpgradeBlackDiamond 10K Switch Only


ExtremeWare XOS 11.1 introduced the concept of hitless upgrade. Hitless upgrade is a mechanism that allows you to upgrade the ExtremeWare XOS software running on the MSMs without taking the switch out of service. Some additional benefits of using hitless upgrade include:

Minimizing network downtime Reducing the amount of traffic lost

Although any method of upgrading software can have an impact on network operation, including interrupting Layer 2 network operation, performing a hitless upgrade can decrease that impact. You must have two MSMs installed in your switch to perform a hitless upgrade. With two MSMs installed in the switch, one assumes the role of primary and the other assumes the role of backup. The primary MSM provides all of the switch management functions including bringing up and programming the I/O modules, running the bridging and routing protocols, and configuring the switch. The primary MSM also synchronizes its configurations with the backup MSM which allows the backup to take over the management functions of the primary.

ExtremeWare XOS 11.3 Concepts Guide

597

Software Upgrade and Boot Options

NOTE
The software on the I/O modules is not updated during a hitless upgrade, only the software on the MSMs. The I/O module software is updated when the switch reboots, or when a disabled slot is enabled.

NOTE
If you download an image to the backup MSM, the image passes through the primary MSM before the image is downloaded to the backup MSM.

Performing a Hitless Upgrade


The steps described in this section assume the following:

You have received the new software image from Extreme Networks, and the image is on either a TFTP server or an external compact flash memory card. See Downloading a New Image on page 591 for more information. You are running ExtremeWare XOS 11.1 or later on both MSMs installed in the switch. Earlier versions of ExtremeWare XOS do not support hitless upgrade.

Summary of Tasks
To perform a hitless upgrade to install and upgrade the ExtremeWare XOS software on your system, complete the following tasks: 1 Determine your selected and booted image partitions. 2 Select the partition to download the image to (and the partition to boot from after installing the image). 3 Download and install the new ExtremeWare XOS software on the backup MSM and reboot the backup MSM, if necessary. 4 Initiate failover from the primary MSM to the backup MSM. 5 Download and install the new ExtremeWare XOS software on the new backup MSM and reboot, if necessary.

Detailed Steps
To perform a hitless upgrade to install and upgrade the ExtremeWare XOS software on your system, complete the following steps: 1 View your selected and booted partition using the following command:
show switch

Output from this command indicates, for each MSM, the selected and booted images and if they are in the primary or the secondary partition. The selected image partition indicates which image will be used at the next reboot. The booted image partition indicates the image used at the last reboot. It is the active partition. 2 Select the partition to download the image to and download and install the new ExtremeWare XOS software on the backup MSM using the following command:

598

ExtremeWare XOS 11.3 Concepts Guide

Understanding Hitless UpgradeBlackDiamond 10K Switch Only


download image [[<hostname> | <ipaddress>] <filename> {{vr} <vrname>} | memorycard <filename>] {<partition>} {msm <slotid>}

NOTE
If the backup MSM is installed in slot B, specify msm B. If the backup MSM is installed in slot A, specify msm A.

Before the download begins, the switch prompts you to install the image immediately after the download is finished. If you install the image immediately after download on the active partition, the switch MSM reboots.

If you download and install the software image on the active partition, you will immediately reboot the MSM. The following message appears when downloading and installing on the active partition:
Image will be installed to the active partition, a reboot required. Do you want to continue? (y or n)

Enter y to continue the installation and reboot the MSM. Enter n to cancel.

If you download and install the software image on the non-active partition, you will need to reboot the MSM manually before you proceed. Use the following command to reboot the switch: reboot {time <month> <day> <year> <hour> <min> <sec>} {cancel} {warm} {msm <slot_id>} Reboot only the backup MSM so the switch will continue to forward traffic.

If you install the image at a later time, use the following command to install the software:
install image <fname> {<partition>} {msm <slotid>} {reboot}

3 Initiate failover from the primary MSM to the backup MSM using the following command:
run msm-failover {force}

When you failover from the primary MSM to the backup MSM, the backup becomes the new primary, runs the software on its active partition, and provides all of the switch management functions. 4 Select the partition to download the image to and download and install the new ExtremeWare XOS software on the new backup MSM (this was the original primary MSM) using the following command:
download image [[<hostname> | <ipaddress>] <filename> {{vr} <vrname>} | memorycard <filename>] {<partition>} {msm <slotid>}

NOTE
If the new backup MSM is installed in slot A, specify msm A. If the new backup MSM is installed in slot B, specify msm B.

Before the download begins, the switch prompts you to install the image immediately after the download is finished. If you install the image immediately after download on the active partition, the switch MSM reboots.

If you download and install the software image on the active partition, you will immediately reboot the MSM. The following message appears when downloading and installing on the active partition:
Image will be installed to the active partition, a reboot required. Do you want to continue? (y or n)

Enter y to continue the installation and reboot the MSM. Enter n to cancel.

ExtremeWare XOS 11.3 Concepts Guide

599

Software Upgrade and Boot Options

If you download and install the software image on the non-active partition, you will need to reboot the MSM manually before you proceed. Use the following command to reboot the switch: reboot {time <month> <day> <year> <hour> <min> <sec>} {cancel} {warm} {msm <slot_id>} Reboot only the backup MSM so the switch will continue to forward traffic.

If you install the image at a later time, use the following command to install the software:
install image <fname> {<partition>} {msm <slotid>} {reboot}

You can also perform a hitless upgrade on ExtremeWare XOS modular software packages (.xmod files). To perform a hitless upgrade of a software package, you must install the core software image first, and the version number of the modular software package must match the version number of the core image that it will be running with. For more detailed information about modular software packages, see Installing a Modular Software Package on page 594. To perform a hitless upgrade, follow the steps described in the previous section, Performing a Hitless Upgrade.

Hitless Upgrade Examples


Using the assumptions described below, the following examples perform a hitless upgrade for a core software image on the BlackDiamond 10K switch:

You have received the new software image from Extreme Networks named bd10K-11.1.0.14.xos. You do not know your selected or booted partitions. You are currently using the primary partition. The image is on a TFTP server named tftphost. You are installing the new image immediately after download. The MSM installed in slot A is the primary. The MSM installed in slot B is the backup. You are running ExtremeWare XOS 11.1 or later on both MSMs.

Performing a Hitless Upgrade on the Inactive Partition


The following example shows the commands necessary to perform a hitless upgrade on the inactive partition. In this example, the secondary partition is the inactive partition:
show switch download image tftphost bd10K-11.1.0.14.xos secondary msm B reboot msm B run msm-failover download image tftphost bd10K-11.1.0.14.xos secondary msm A reboot msm A

After executing these commands, MSM B will be the master, and the secondary partition will be the active partition for both MSMs. The previously running software will reside on the inactive partition (now, the primary partition).

600

ExtremeWare XOS 11.3 Concepts Guide

Saving Configuration Changes

Performing a Hitless Upgrade on the Current Partition


The following example shows the commands necessary to perform a hitless upgrade on the current partition. In this example, the primary partition is the current partition:

NOTE
If you download the image to the current partition, specifying the partition name is optional. show switch download image tftphost bd10K-11.1.0.14.xos primary msm B run msm-failover download image tftphost bd10K-11.1.0.14.xos primary msm A

After executing these commands, MSM B will be the master, and the primary partition will be the active partition for both MSMs. The previously running software was overwritten on the primary partition, and is no longer on the switch.

Saving Configuration Changes


The configuration is the customized set of parameters that you have selected to run on the switch. As you make configuration changes, the new settings are stored in run-time memory. Settings that are stored in run-time memory are not retained by the switch when the switch is rebooted. To retain the settings and have them loaded when you reboot the switch, you must save the configuration to nonvolatile storage. The switch can store multiple user-defined configuration files, each with its own filename. By default, the switch has two prenamed configurations: a primary and a secondary configuration. When you save configuration changes, you can select to which configuration you want the changes saved or you can save the changes to a new configuration file. If you do not specify a filename, the changes are saved to the configuration file currently in use. Or if you have never saved any configurations, you are asked to save your changes to the primary configuration.

NOTE
Configuration files have a .cfg file extension. When you enter the name of the file in the CLI, the system automatically adds the .cfg file extension.

If you have made a mistake or you must revert to the configuration as it was before you started making changes, you can tell the switch to use the backup configuration on the next reboot. Each filename must be unique and can be up to 32 characters long. Filenames are also case sensitive. For information on filename restrictions, please refer to the specific command in the ExtremeWare XOS Command Reference Guide. To save the configuration, use the following command:
save configuration {primary | secondary | <existing-config> | <new-config>}

Where the following is true:

ExtremeWare XOS 11.3 Concepts Guide

601

Software Upgrade and Boot Options


primarySpecifies the primary saved configuration secondarySpecifies the secondary saved configuration existing-configSpecifies an existing user-defined configuration (displays a list of available userdefined configuration files) new-configSpecifies a new user-defined configuration

You are then prompted to save the changes. Enter y to save the changes or n to cancel the process. To use the configuration, use the following command:
use configuration [primary | secondary | <file_name>]

Where the following is true:


primarySpecifies the primary saved configuration secondarySpecifies the secondary saved configuration file_nameSpecifies an existing user-defined configuration (displays a list of available user-defined configuration files)

The configuration takes effect on the next reboot.

NOTE
If the switch is rebooted while in the middle of saving a configuration, the switch boots to factory default settings if the previously saved configuration file is overwritten. The configuration that is not in the process of being saved is unaffected.

Viewing a Configuration
You can view the current configuration on the switch by using the following command:
show configuration {<module-name>}

You can also view just the portion of the configuration that applies to a particular module (for example, SNMP) by using the module-name parameter. You can send output from the show configuration {<module-name>} command to the Extreme Networks Technical Support department for problem-solving purposes. The output maintains the command line interface (CLI) format of the current configuration on the switch.

Returning to Factory Defaults


To return the switch configuration to factory defaults, use the following command:
unconfigure switch

This command resets the entire configuration, with the exception of user accounts and passwords that have been configured and the date and time. To unset the currently selected configuration image, reset all switch parameters, and reboot the switch, use the following command:
unconfigure switch {all}

602

ExtremeWare XOS 11.3 Concepts Guide

Using TFTP to Upload the Configuration

Using TFTP to Upload the Configuration


You can upload the current configuration to a Trivial File Transfer Protocol (TFTP) server on your network. The uploaded configuration file retains your system configuration and is saved in Extensible Markup Language (XML) format. This allows you to send a copy of the configuration file to the Extreme Networks Technical Support department for problem-solving purposes. To view your current switch configuration, use the show configuration {<module-name>} command available on your switch. Do not use a text editor to view or modify your switch configuration files. For more information about the show configuration {<module-name>} command, see the ExtremeWare XOS Command Reference Guide. For more information about TFTP, see Using the Trivial File Transfer Protocol on page 69. To upload the configuration to a TFTP server, use the following command:
tftp [<host-name> | <ip_address>] -p -l <local_file> {-r <remote_file>}

Where the following is true:


host-nameIs the host name of the TFTP server ip_addressIs the IP address of the TFTP server -pPuts the specified file from the local host and copies it to the TFTP server -l <local_file>Specifies the name of the configuration file that you want to save to the TFTP

server

-r <remote_file>Specifies the name of the configuration file on the TFTP server

If you upload a configuration file and see the following message:


Error: No such file or directory

Check to make sure that you entered the filename correctly, including the .cfg extension, and that you entered the correct host name or IP address for the TFTP server. If your upload is successful, the switch displays a message similar to the following:
Uploading megtest1.cfg to TFTPhost ... done!

Using TFTP to Download the Configuration


You can download previously saved XML formatted XOS configuration files from a TFTP host to the switch to modify the switch configuration. Do not use a text editor to view or modify your switch configuration files; modify your switch configurations directly in the CLI. To download the configuration, use the following command:
tftp [<host-name> | <ip_address>] -g -r <remote_file> {-l <local_file>}

Where the following is true:


host-nameIs the host name of the TFTP server ip_addressIs the IP address of the TFTP server

ExtremeWare XOS 11.3 Concepts Guide

603

Software Upgrade and Boot Options


-gGets the specified file from the TFTP server and copies it to the local host -r <remote_file>Specifies the name of the configuration file that you want to retrieve from the

TFTP server

-l <local_file>Specifies the name of the configuration file on the switch

If you download a configuration file and see the following message:


Error: Transfer timed out

Check to make sure that you entered the filename correctly, including the .cfg extension, and that you entered the correct host name or IP address for the TFTP server. If your download is successful, the switch displays a message similar to the following:
Downloading megtest2.cfg to switch... done!

Configurations are downloaded and saved into the switch nonvolatile memory. The configuration is applied after you reboot the switch. If the configuration currently running in the switch does not match the configuration that the switch used when it originally booted, an asterisk (*) appears before the command line prompt when using the CLI.

Synchronizing MSMsModular Switches Only


On a dual MSM system, you can take the primary MSM configurations and images and replicate them on the backup MSM using the following command:
synchronize

CAUTION
During a synchronization, half of the switch fabric is lost. When the primary MSM finishes replicating its configurations and images to the backup MSM, the full switch fabric is restored.

In addition to replicating the configuration settings and images, this command also replicates which configuration or image the MSM should use on subsequent reboots. This command does not replicate the run-time configuration. You must use the save configuration command to store the run-time configuration first.

Additional Behavior on the BlackDiamond 8800 Family of Switches Only


On the BlackDiamond 8800 family of switches (formerly known as Aspen), the I/O ports on the backup MSM go down when you synchronize the MSMs. When the primary MSM finishes replicating its configurations and images to the backup MSM, the I/O ports on the backup MSM come back up.

604

ExtremeWare XOS 11.3 Concepts Guide

Accessing the Bootloader

Automatic Synchronization of Configuration Files


On a dual MSM system, ExtremeWare XOS automatically synchronizes all of the configuration files from the primary MSM to the backup MSM if the switch detects that the backup MSMs configuration file contents are different from the primary MSM. You do not configure this behavior. The switch deletes the old configuration files on the backup MSM only upon a successful file synchronization. If an error occurs, the switch does not delete the old configuration files on the backup MSM. For example, if you install a backup MSM that contains different configuration files from the primary MSM, the old configuration files are deleted after a successful bootup of the backup MSM. To see a complete listing of the configuration files on your system, use the ls command. For more detailed information, see the section Replicating Data Between Nodes on page 72.

Accessing the Bootloader


The Bootloader of the switch initializes certain important switch variables during the boot process. In the event the switch does not boot properly, some boot option functions can be accessed through the Bootloader. Interaction with the Bootloader is required only under special circumstances and should be done only under the direction of Extreme Networks Customer Support. The necessity of using these functions implies a nonstandard problem which requires the assistance of Extreme Networks Customer Support. To access the Bootloader menu, follow these steps: 1 Attach a serial cable to the console port of the switch. 2 Attach the other end of the serial cable to a properly configured terminal or terminal emulator, power cycle the switch, and press the spacebar key on the keyboard of the terminal during the bootup process. NOTE
To access the Bootloader, you have to press the spacebar key immediately after a power cycle of the MSM in order to get into the Bootloader application.

As soon as you see the BOOTLOADER> prompt (BlackDiamond 10K) or the BootRom -> prompt (BlackDiamond 8800 family of switches), release the spacebar. You can issue a series of commands to:

View the installed images Select the image to boot from Select the configuration to use Load a recovery image over the management port Load a recovery image over the serial port (BlackDiamond 10K switch only)

To see a list of available commands or additional information about a specific command, enter h or type help. The following describes some ways that you can use the Bootloader.

Viewing imagesTo display a list of installed images, use the show image command.

ExtremeWare XOS 11.3 Concepts Guide

605

Software Upgrade and Boot Options

Selecting an imageTo change the image that the switch boots from in flash memory, use the boot {image number} command. If you specify image number, the specified image is booted. If you do not specify an image number, the default image is booted. Selecting a configurationTo select a different configuration from the one currently running, use the config {alt | default | <filename> | none} command. This command is useful if you experience a problem with the current configuration and there is an alternate configuration available.

altSpecifies the alternate configuration file defaultSpecifies the default configuration file filenameSpecifies a configuration filename noneUses no configuration

To view the current configuration, use this command without any arguments. To exit the Bootloader, use the boot command. Specifying boot runs the currently selected ExtremeWare XOS image.

Upgrading the BootROMBlackDiamond 10K Switch Only


Upgrade the BootROM from a TFTP server on the network or an external compact flash memory card installed in the compact flash slot of the MSM, after the switch has booted. Upgrade the BootROM only when asked to do so by an Extreme Networks technical representative. To upgrade the BootROM, use the following command:
download bootrom [[<ipaddress> | <hostname>] <filename> {{vr} <vrname>} | memorycard <filename>] {msm <slotid>}

Upgrading the BootROMSummit X450 Switch Only


The Summit X450 switch has a two-stage BootROM. The first stage, called bootstrap, does basic initialization of the switch processor and will load one of two second-stage bootloaders (called primary and secondary). If the switch does not boot properly, both bootstrap and bootloader allows the user to access the boot options using the CLI. If necessary, the bootloader can be updated after the switch has booted, using TFTP. You can upgrade the BootROM from a TFTP server on the network after the switch has booted and only when asked to do so by an Extreme Networks technical representative. To upgrade the BootROM, use the following command:
download bootrom [[<ipaddress> | <hostname>] <filename> {{vr} <vrname>} | memorycard <filename>] {msm <slotid>}

NOTE
The Summit X450 switch does not support user-created VRs.

606

ExtremeWare XOS 11.3 Concepts Guide

Upgrading the FirmwareBlackDiamond 8800 Family of Switches Only

Accessing the Bootstrap CLI on the Summit X450


The bootstrap CLI contains command to support the selection of which bootloader to use. To access the bootstrap CLI, follow these steps: 1 Attach a serial cable to the serial console port of the switch. 2 Attach the other end of the serial cable to a properly configured terminal or terminal emulator. 3 Power cycle or reboot the switch. 4 As soon as you see the Bootstrap Banner, press the spacebar. The BOOTSTRAP> prompt appears on the screen. For detailed information and instructions on accessing the bootloader, see Accessing the Bootloader on page 605.

Upgrading the FirmwareBlackDiamond 8800 Family of Switches Only


Firmware images are bundled with ExtremeWare XOS software images. ExtremeWare XOS automatically compares the existing firmware image flashed into the hardware with the firmware image bundled with the ExtremeWare XOS image when you:

Download a new version of ExtremeWare XOS to the active partition. Install a new module into an active chassis.

After a firmware image upgrade, messages are sent to the log. You can configure the switch to automatically upgrade the firmware when a different image is detected, or you can have the switch prompt you to confirm the upgrade process. To configure the switchs behavior during a firmware upgrade, use the following command:
configure firmware [auto-install | install-on-demand]

Where the following is true:

auto-installSpecifies ExtremeWare XOS to automatically upgrade the firmware if the software detects a newer firmware image is available. The switch does not prompt you to confirm the firmware upgrade. on-demandSpecifies the switch to prompt you to upgrade the firmware when ExtremeWare XOS determines that a newer firmware image is available. This is the default behavior.

Use the install firmware {force} command to install the firmware bundled with the ExtremeWare XOS image on the BlackDiamond 8800 family of switches. Specify the force parameter only under guidance from Extreme Networks Technical Support personnel. Forcing a firmware upgrade may cause incompatibility issues between the firmware and the software installed on the MSM. During the firmware upgrade, do not cycle down or disrupt the power to the switch. If a power interruption occurs, the firmware may be corrupted and need to be recovered. ExtremeWare XOS automatically attempts to recover corrupted firmware; however, in some situations user intervention is required.

ExtremeWare XOS 11.3 Concepts Guide

607

Software Upgrade and Boot Options Power over Ethernet (PoE) firmware is always automatically upgraded or downgraded to match the operational ExtremeWare XOS code image. This configuration is not applicable to PoE firmware.

608

ExtremeWare XOS 11.3 Concepts Guide

Troubleshooting

This appendix describes some troubleshooting tips on the following topics:


Troubleshooting Checklists on page 609 LEDs on page 612 Using the Command Line Interface on page 614 Using Standalone ELRP to Perform Loop Tests on page 620 Using the Rescue Software ImageModular Switches Only on page 623 Debug Mode on page 626 Saving Debug Information to the Memory Card on page 626 TOP Command on page 629 TFTP Server Requirements on page 629 System Health CheckModular Switches Only on page 629 System Odometer on page 631 Temperature Operating Range on page 632 Corrupted BootROM on the BlackDiamond 8800 Family of Switches on page 633 Inserting Powered Devices in the PoE ModuleBlackDiamond 8800 Family of Switches Only on page 633 Untagged Frames on the 10 Gbps ModuleBlackDiamond 10K Switch Only on page 633 Running MSM Diagnostics from the BootloaderBlackDiamond 10K Switch Only on page 633 Contacting Extreme Networks Technical Support on page 634

If you encounter problems when using the switch, this appendix may be helpful. If you have a problem not listed here or in the release notes, please contact Extreme Networks Technical Support.

Troubleshooting Checklists
The information in this section provides simple troubleshooting checklists for Layer 1, Layer 2, and Layer 3. The commands and recommendations described are applicable to both IPv4 and IPv6 environments unless otherwise specified. If more detailed information about a topic is available, you are referred to the applicable section in this appendix.

Layer 1
When troubleshooting Layer 1 issues, verify:

The installation of cables and connectors. The behavior of LED status lights. For additional information about LEDs, see LEDs on page 612.

ExtremeWare XOS 11.3 Concepts Guide

609

Troubleshooting

That the port is enabled, the link status is active, and speed and duplex parameters match the port settings at the other end of the cable. Use the show ports configuration command to display the configuration of one or more ports. That the packets are being received and transmitted. Use the show ports {<port_list>} statistics {no-refresh} command to display the number of packets being received and transmitted.

That there are no packet errors. Use the following commands to display packet error statistics:

show ports {<port_list>} rxerrors {no-refresh}Displays receive error statistics show ports {<port_list>} txerrors {no-refresh}Displays transmit error statistics show ports {mgmt | <port_list>} collisions {no-refresh}Displays collision statistics

Layer 2
When troubleshooting Layer 2 issues, verify:

That the MAC addresses are learned, in the correct Virtual LAN (VLAN), and are not blackhole entries. Use the show fdb command to display FDB entries. Your VLAN configuration, including the VLAN tag, ports in the VLAN, and whether or not the ports are tagged. Use the show vlan detail command to display detailed information for each VLAN configured on the switch. For additional VLAN troubleshooting tips, see VLANs on page 618.

Your Spanning Tree Protocol (STP) configuration, including the STP domain (STPD) number, VLAN assignment, and port state. Use the following commands to display STP information:

show stpd detailDisplays the STP settings on the switch show stpd portsDisplays the STP state of a port show vlan stpdDisplays the STP configuration of the ports assigned to a specific VLAN

For additional STP troubleshooting tips, see STP on page 618.

Layer 3
When troubleshooting Layer 3 issues, verify:

The IP address assigned to each VLAN router interface. Use the show vlan command to display summary information for all of the VLANs configured on the device.

That IP forwarding is enabled, the routing protocol is globally enabled, and the routing protocol is enabled for a VLAN. To display the configuration information for a specific VLAN, use one of the following commands:

show ipconfig {ipv4} {vlan <vlan_name>}IPv4 environment show ipconfig ipv6 {vlan <vlan_name> | tunnel <tunnelname>}IPv6 environment

610

ExtremeWare XOS 11.3 Concepts Guide

Troubleshooting Checklists

Which destination networks are in the routing table and the source of the routing entry. To display the contents of the routing table or the route origin priority, use one of the following commands:

show iprouteIPv4 environment show iproute ipv6IPv6 environment

To display the contents of the routing table only for routes of a specified origin, use one of the following commands:

show iproute originIPv4 environment show iproute ipv6 originIPv6 environment

That the IP Address Resolution Protocol (ARP) table has the correct entries. NOTE
The ARP table is applicable only in IPv4 environments.

Use the show iparp command to display the contents of the IP ARP table.

That the Neighbor Discovery (ND) cache has the correct entries. NOTE
The ND cache is applicable only in IPv6 environments.

Use the show neighbor-discovery cache ipv6 command to display the contents of the ND cache.

IP routing protocol statistics for the CPU of the switch. Only statistics of the packets handled by the CPU are displayed. To display IP statistics for the CPU of the switch, use one of the following commands:

show ipstatsIPv4 environment show ipstats ipv6IPv6 environment

Your Open Shortest Path First (OSPF) configuration, including the OSPF area ID, router state, link cost, OSPF timers, interface IP address, and neighbor list. NOTE
OSPF is applicable only in IPv4 environments.

Use the following commands to display OSPF information:


show ospfDisplays global OSPF information for the switch show ospf areaDisplays information related to OSPF areas show ospf area detailDisplays detailed information related to OSPF areas show ospf interfaces detailDisplays detailed information about OSPF interfaces

Your OSPFv3 configuration, including the OSPFv3 area ID, router state, link cost, OSPFv3 timers, interface IP address, and neighbor list. NOTE
OSPFv3 is applicable only in IPv6 environments.

ExtremeWare XOS 11.3 Concepts Guide

611

Troubleshooting Use the following commands to display OSPFv3 information:


show ospfv3Displays global OSPFv3 information for the switch show ospfv3 areaDisplays information related to OSPFv3 areas show ospfv3 interfacesDisplays detailed information about OSPFv3 interfaces

Your Routing Information Protocol (RIP) configuration, including RIP poison reverse, split horizon, triggered updates, transmit version, and receive version. NOTE
RIP is applicable only in IPv4 environments.

Use the show rip command to display detailed information about how you have RIP configured on the switch.

RIP activity and statistics for all VLANs on the switch. NOTE
RIP is applicable only in IPv4 environments.

Use the show rip interface detail command to display RIP-specific statistics for all VLANs.

Your RIP next generation (RIPng) configuration, including RIPng poison reverse, split horizon, triggered updates, transmit version, and receive version. NOTE
RIPng is applicable only in IPv6 environments.

Use the show ripng command to display detailed information about how you have RIPng configured on the switch.

RIPng activity and statistics for all VLANs on the switch. NOTE
RIPng is applicable only in IPv6 environments.

Use the show ripng interface command to display RIPng-specific statistics for all VLANs.

End-to-end connectivity. Use the ping command to test for connectivity to a specific host. The routed path between the switch and a destination end station. Use the traceroute command to verify and trace the routed path.

LEDs
Power LED does not light: Check that the power cable is firmly connected to the device and to the supply outlet.

612

ExtremeWare XOS 11.3 Concepts Guide

LEDs On powering-up, the MGMT LED lights yellow: The device has failed its Power On Self Test (POST) and you should contact your supplier for advice. A link is connected, but the Status LED does not light: Check that:

All connections are secure. Cables are free from damage. The devices at both ends of the link are powered-up. Both ends of the Gigabit link are set to the same autonegotiation state. The Gigabit link must be enabled or disabled on both sides. If the two sides are different, typically the side with autonegotiation disabled will have the link LED lit, and the side with autonegotiation enabled will not be lit. The default configuration for a Gigabit port is autonegotiation enabled. Verify by entering the following command:
show ports configuration

On power-on, some I/O modules do not boot: Check the output of the show power budget command to see if all power supplies display the expected input voltage. Also refer to the section Power Management Guidelines on page 80 for more detailed information about power management. ERR LED on the Management Switch Fabric Module (MSM) turns amber: Check the syslog message for critical software errors. To reset the ERR LED and clear the log, use the following command and reboot the switch:
clear log static

If you continue to see critical software errors or the ERR LED is still amber after issuing the clear log static command and a switch reboot, contact Extreme Networks Technical support for further assistance. Status LED on the I/O module turns amber: Check the syslog message for a related I/O module error. If the error is an inserted I/O module that conflicts with the software configuration, use one of the following commands to reset the slot configuration:
clear slot configure slot <slot> module <module_type>

Otherwise, contact Extreme Networks Technical Support for further assistance. ENV LED on the MSM turns amber: Check each of the power supplies and all of the fans. Additionally, you display the status in the show
power and show fans displays.

ExtremeWare XOS 11.3 Concepts Guide

613

Troubleshooting Switch does not power up: All products manufactured by Extreme Networks use digital power supplies with surge protection. In the event of a power surge, the protection circuits shut down the power supply. To reset the power, unplug the switch for 1 minute, plug it back in, and attempt to power-up the switch. If this does not work, try using a different power source (different power strip/outlet) and power cord.

Using the Command Line Interface


This section describes helpful information for using and understanding the command line interface (CLI). This section contains the following topics:

General Tips and Recommendations on page 614 MSM PromptModular Switches Only on page 616 Command Prompt on page 616 Port Configuration on page 617 VLANs on page 618 STP on page 618 ESRP on page 619 VRRP on page 620

General Tips and Recommendations


The initial welcome prompt does not display: Check that:

Your terminal or terminal emulator is correctly configured Your terminal or terminal emulator has the correct settings:

9600 baud 8 data bits 1 stop bit no parity XON/OFF flow control enabled

For console port access, you may need to press [Return] several times before the welcome prompt appears. The SNMP Network Manager cannot access the device: Check that:

The Simple Network Management Protocol (SNMP) access is enabled for the system. The device IP address, subnet mask, and default router are correctly configured, and that the device has been reset. The device IP address is correctly recorded by the SNMP Network Manager (refer to the user documentation for the Network Manager).

614

ExtremeWare XOS 11.3 Concepts Guide

Using the Command Line Interface


The community strings configured for the system and Network Manager are the same. The SNMPv3 USM, Auth, and VACM configured for the system and Network Manager are the same.

The Telnet workstation cannot access the device: Check that:

The device IP address, subnet mask, and default router are correctly configured, and that the device has been reset. You entered the IP address of the switch correctly when invoking the Telnet facility. Telnet access is enabled for the switch.

If you attempt to log in and the maximum number of Telnet sessions are being used, you should receive an error message indicating so. Traps are not received by the SNMP Network Manager: Check that the SNMP Network Manager's IP address and community string are correctly configured, and that the IP address of the Trap Receiver is configured properly on the system. The SNMP Network Manager or Telnet workstation can no longer access the device: Check that:

Telnet access or SNMP access is enabled for the system. The port through which you are trying to access the device has not been disabled. If it is enabled, check the connections and network cabling at the port. The port through which you are trying to access the device is in a correctly configured Virtual LAN (VLAN). The community strings configured for the device and the Network Manager are the same.

Try accessing the device through a different port. If you can now access the device, a problem with the original port is indicated. Re-examine the connections and cabling. A network problem may be preventing you from accessing the device over the network. Try accessing the device through the console port. Permanent entries remain in the FDB: If you have made a permanent entry in the FDB that requires you to specify the VLAN to which the entry belongs and then deleted the VLAN, the FDB entry remains. Although this does not harm the system, if you want to removed the entry, you must manually delete it from the FDB. Default and static routes: If you have defined static or default routes, those routes remain in the configuration independent of whether the VLAN and VLAN IP address that used them remains. You should manually delete the routes if no VLAN IP address is capable of using them. You forget your password and cannot log in: If you are not an administrator, another user having administrator access level can log in, delete your user name, and create a new user name for you, with a new password.

ExtremeWare XOS 11.3 Concepts Guide

615

Troubleshooting Alternatively, another user having administrator access level can log in and initialize the device. This will return all configuration information (including passwords) to the initial values. In the case where no one knows a password for an administrator level user, contact your supplier.

MSM PromptModular Switches Only


You do not know which MSM you are connected to: If you use a console connection to access and configure the switch, you should connect to the console port of the primary MSM, not the backup MSM. To determine which console port you are connected to issue the show switch command. The output displays both the primary and backup MSMs, if installed, and an asterisk (*) appears to the right of the MSM you are connected to. The following truncated sample output indicates that you are connected to MSM-A, the primary MSM:
MSM: MSM-A * MSM-B

You have user privileges, not administrator privileges, on the backup MSM: If you establish a console connection to access the backup MSM, only user privileges are available. This is true regardless of the privileges configured on the primary MSM. If you enter an administrator level command on the backup MSM, the switch displays a message stating that the command is only supported on the primary MSM.

Command Prompt
You do not know if the switch configuration has been saved: If an asterisk (*) precedes the command prompt, a new change to the switch configuration has not been saved. To save the configuration, issue the save configuration command. After you save the configuration, the asterisk (*) no longer precedes the command prompt. You do not know if you are logged in as an administrator or a user: Observe the console prompt. If you are logged in as an administrator, the prompt ends with the hash symbol(#). If you are logged in as a user, the prompt ends with a greater than sign (>). The following is sample output from an administrator-level account:
BD-10808.1 #

The following is sample output from a user-level account:


BD-10808.1 >

Port Configuration
No link light on 10/100 Base port: If patching from a switch to another switch, ensure that you are using a category 5 (CAT5) crossover cable. This is a CAT5 cable that has pins 1 and 2 on one end connected to pins 3 and 6 on the other end.

616

ExtremeWare XOS 11.3 Concepts Guide

Using the Command Line Interface Excessive RX CRC errors: When a device that has autonegotiation disabled is connected to an Extreme Networks switch with autonegotiation enabled, the Extreme Networks switch links at the correct speed, but in half-duplex mode. The Extreme Networks switch 10/100 physical interface uses a method called parallel detection to bring up the link. Because the other network device is not participating in autonegotiation (and does not advertise its capabilities), parallel detection on the Extreme Networks switch is able only to sense 10 Mbps versus 100 Mbps speed and not the duplex mode. Therefore, the switch establishes the link in half-duplex mode using the correct speed. The only way to establish a full-duplex link is either to force it at both sides, or run autonegotiation on both sides (using full-duplex as an advertised capability, which is the default setting on the Extreme Networks switch).

NOTE
A mismatch of duplex mode between the Extreme switch and another network device causes poor network performance. Viewing statistics using the show ports rxerrors command on the Extreme Networks switch may display a constant increment of CRC errors. This is characteristic of a duplex mismatch between devices. This is NOT a problem with the Extreme Networks switch.

Always verify that the Extreme Networks switch and the network device match in configuration for speed and duplex. No link light on Gigabit fiber port: Check that:

The transmit fiber goes to the receive fiber side of the other device and vice-versa. All Gigabit fiber cables are of the crossover type. The Gigabit ports are set to Auto Off (using the command configure ports <port_list> auto off speed [10 | 100 | 1000 | 10000] duplex [half | full]) if you are connecting the Extreme Networks switch to devices that do not support autonegotiation. By default, the Extreme Networks switch has autonegotiation set to On for Gigabit ports and set to Off for 10 Gigabit ports.

You are using multimode fiber (MMF) when using a 1000BASE-SX Gigabit Ethernet Interface Connector (GBIC), and single-mode fiber (SMF) when using a 1000BASE-LX GBIC. 1000BASE-SX technology does not work with SMF. The 1000BASE-LX technology works with MMF but requires the use of a mode conditioning patchcord (MCP).

VLANs
You cannot add a port to a VLAN: If you attempt to add a port to a VLAN and get an error message similar to:
localhost:7 # configure vlan marketing add ports 1:1,1:2 Error: Protocol conflict when adding untagged port 1:1. Either add this port as tagged or assign another protocol to this VLAN.

you already have a VLAN using untagged traffic on a port. Only one VLAN using untagged traffic can be configured on a single physical port.

ExtremeWare XOS 11.3 Concepts Guide

617

Troubleshooting You verify the VLAN configuration using the following command:
show vlan {detail |<vlan_name> {stpd}}

The solution for this error using this example is to remove ports 1 and 2 from the VLAN currently using untagged traffic on those ports. If this were the default VLAN, the command would be:
localhost:23 # configure vlan default delete ports 1:1,1:2

You can now re-enter the previous command without error:


localhost:26 # configure vlan marketing add ports 1:1,1:2

VLAN names: There are restrictions on VLAN names. They cannot contain whitespaces and cannot start with a numeric value. VLANs, IP addresses, and default routes: The system can have an IP address for each configured VLAN. You must configure an IP address associated with a VLAN if you intend to manage (Telnet, SNMP, ping) through that VLAN or route IP traffic. You can also configure multiple default routes for the system. The system first tries the default route with the lowest cost metric.

STP
You have connected an endstation directly to the switch and the endstation fails to boot correctly: The switch has the Spanning Tree Protocol (STP) enabled, and the endstation is booting before the STP initialization process is complete. Specify that STP has been disabled for that VLAN, or turn off STP for the switch ports of the endstation and devices to which it is attempting to connect; then, reboot the endstation. Spanning Tree Domain names: There are restrictions on Spanning Tree Domain (STPD) names. They cannot contain whitespaces and cannot start with a numeric value. You cannot add ports within a VLAN to the specified STPD: Check to ensure that you are adding ports that already exist in the carrier VLAN. If you see an error similar to the following:
Error: Cannot add VLAN default port 3:5 to STP domain

You might be attempting to add:

Another 802.1D mode STP port to a physical port that already contains an 802.1D mode STP port (only one 802.1D encapsulation STP port can be configured on a particular STP port). A carrier VLAN port to a different STP domain than the carrier VLAN belongs. A VLAN and/or port for which the carrier VLAN does not yet belong.

618

ExtremeWare XOS 11.3 Concepts Guide

Using the Command Line Interface

NOTE
This restriction is only enforced in an active STPD and when you enable STP to make sure you have a legal STP configuration.

Only one carrier VLAN can exist in an STPD: Only one carrier VLAN can exist in a given STPD although some of the ports on the carrier VLAN can be outside the control of any STPD at the same time. The StpdID must be identical to the VLANid of the carrier VLAN in that STPD. The switch keeps aging out endstation entries in the switch FDB: If the switch continues to age out endstation entries in the switch FDB:

Reduce the number of topology changes by disabling STP on those systems that do not use redundant paths. Specify that the endstation entries are static or permanent.

ESRP
ESRP names: There are restrictions on Extreme Standby Router Protocol (ESRP) names. They cannot contain whitespaces and cannot start with a numeric value. You cannot enable an ESRP domain: Before you enable a specific ESRP domain, it must have a domain ID. A domain ID is either a userconfigured number or the 802.1Q tag (VLANid) of the tagged master VLAN. The domain ID must be identical on all switches participating in ESRP for that particular domain. If you do not have a domain ID, you cannot enable ESRP on that domain. Please note the following on the interaction of tagging, ESRP, and ESRP domain IDs:

If you have an untagged Master VLAN, you must specify an ESRP domain ID. If you have a tagged master VLAN, ESRP uses the 802.1Q tag (VLANid) of the master VLAN for the ESRP domain ID. If you do not use the VLANid as the domain ID, you must specify a different domain ID.

You cannot delete the master VLAN from the ESRP domain: If you attempt to remove the master VLAN before disabling the ESRP domain, you see an error message similar to the following:
ERROR: Failed to delete master vlan for domain "esrp1" ; ESRP is enabled!

If this happens, do the following:


Disable the ESRP domain using the disable esrp command. Remove the master VLAN from the ESRP domain using the configure esrp delete master command.

ExtremeWare XOS 11.3 Concepts Guide

619

Troubleshooting

VRRP
You cannot define VRRP virtual router parameters: Before configuring any virtual router parameters for VRRP, you must first create the VRRP instance on the switch. If you define VRRP parameters before creating the VRRP, you may see an error similar to the following:
Error: VRRP VR for vlan vrrp1, vrid 1 does not exist. Please create the VRRP VR before assigning parameters. Configuration failed on backup MSM, command execution aborted!

If this happens, do the following:


Create a VRRP instance using the create vrrp vlan vrid command. Configure the VRRP instances parameters.

Using Standalone ELRP to Perform Loop Tests


Having a tool to determine if the network has any loops is extremely useful. There are various other protocols that can exploit this tool to prevent network loops. There are also situations where you might want to check the topology for the existence or absence of a loop. The Extreme Loop Recovery Protocol (ELRP) allows you to prevent, detect, and recover from Layer 2 loops in the network. You can use ELRP with other protocols such as ESRP, as described in the section Using ELRP with ESRP on page 476. Other protocols such as Ethernet Automatic Protection Switching (EAPS) requires that a network have a ring topology to operate. In this case you can use ELRP to ensure that the network has a ring topology. ELRP is used to detect network loops in a Layer 2 network. A switch running ELRP transmits multicast packets with a special MAC destination address out of some or all of the ports belonging to a VLAN. All of the other switches in the network treat this packet as a regular, multicast packet and flood it to all of the ports belonging to the VLAN. If the packets transmitted by a switch are received back by that switch, this indicates a loop in the Layer 2 network. Once a loop is detected through ELRP, different recovery actions can be taken such as blocking certain ports to prevent loop or logging a message to system log. The action taken is largely dependent on the protocol using ELRP to detect loops in the network. Using ELRP with ESRP is one way you can use ELRP. For more information about configuring ESRP and ELRP, see the section Using ELRP with ESRP on page 476. Another way to use ELRP is to invoke standalone ELRP commands to determine whether a network has an Layer 2 loop or not. The remaining sections describe how to configure standalone ELRP on your switch. This section describes the following topics:

About Standalone ELRP on page 621 Configuring Standalone ELRP on page 621 Displaying Standalone ELRP Information on page 622

620

ExtremeWare XOS 11.3 Concepts Guide

Using Standalone ELRP to Perform Loop Tests

About Standalone ELRP


Standalone ELRP gives you the ability to send ELRP packets, either periodically or on an ad hoc oneshot basis on a specified subset of VLAN ports. If any of these transmitted packets is received back then standalone ELRP can perform a configured action such as sending a log message to the system log file or sending a trap to the SNMP manager. Standalone ELRP allows you to:

Configure ELRP packet transmission on specified VLANs. Specify some or all the ports of VLAN for packet transmission. NOTE
Reception of packets is not limited to any specific ports of the VLAN and cannot be configured.

Configure transmission of ELRP packets on specified ports of a VLAN periodically with the added ability to configure the interval between consecutive timings. Save and restore standalone ELRP configuration across reboots. Request periodic or non-periodic transmission of ELRP packets on specified ports of a VLAN. For non-periodic ELRP requests:

You can specify the number of times ELRP packets must be transmitted and the interval between consecutive transmissions. A message is printed to the console and logged into the system log file indicating detection of network loop when ELRP packets are received back or no packets are received within the specified duration. There is no need to trap to the SNMP manager. If ELRP packets are received back, a message is printed to the system log file and a trap is sent to the SNMP manager indicating detection of a network loop.

For periodic ELRP requests:

Configuring Standalone ELRP


This section describes configuring ELRP packet transmission to detect network loops. The ELRP client (standalone ELRP) must be enabled globally in order for it to work on any VLANs. To globally enable the ELRP client use the following command:
enable elrp-client

The ELRP client can be disabled globally so that none of the ELRP VLAN configurations take effect. Use the following command to globally disable the ELRP client:
disable elrp-client

To start one-time, non-periodic ELRP packet transmission on specified ports of a VLAN using a particular count and interval, use one of the following commands:

configure elrp-client one-shot <vlan_name> ports [<ports> | all] interval <sec> retry <count> [log | print | print-and-log](This command is backward compatible with

Extreme Networks switches running the ExtremeWare software.)

run elrp <vlan_name> {ports <ports>} {interval <sec>} {retry <count>}

ExtremeWare XOS 11.3 Concepts Guide

621

Troubleshooting These commands start one-time, non-periodic ELRP packet transmission on the specified ports of the VLAN using the specified count and interval. If any of these transmitted packets is returned, indicating loopback detection, the ELRP client can perform a configured action such as logging a message in the system log file or printing a log message to the console. There is no need to trap to the SNMP manager for non-periodic requests. To start periodic ELRP packet transmission on specified ports of a VLAN using a particular interval, use one of the following commands:
configure elrp-client periodic <vlan_name> ports [<ports> | all] interval <sec> [log | log-and-trap | trap]

This command starts periodic ELRP packet transmission on the specified ports of the VLAN using the specified interval. If any of these transmitted packets is returned, indicating loopback detection, the ELRP client can perform a configured action such as logging a message in the system log file and/or sending a trap to the SNMP manager. To disable a pending one-shot or periodic ELRP request for a specified VLAN use the following command:
unconfigure elrp-client <vlan_name>

Displaying Standalone ELRP Information


To display summary ELRP information, use the following command:
show elrp

The following information about ELRP appears:


State of ELRP (enabled/disabled). Clients registered with ELRP ELRP packets transmitted ELRP packets received

For more detailed information about the output associated with the show elrp command, see the ExtremeWare XOS Command Reference Guide.

Using the Rescue Software ImageModular Switches Only


WARNING!
The rescue image completely re-initializes the system. All data residing on the switch is cleared, including configuration files, policy files, and other system-related files. Use this feature only with the guidance of Extreme Networks Technical Support.

The concept of a rescue software image was introduced in ExtremeWare XOS 11.1. The rescue software image recovers a switch that does not boot up by initializing the internal compact flash and installing the ExtremeWare XOS software on both primary and secondary images of the compact flash. To use the

622

ExtremeWare XOS 11.3 Concepts Guide

Using the Rescue Software ImageModular Switches Only rescue software image, you must be running ExtremeWare XOS 11.1 or later. Earlier versions of ExtremeWare XOS do not support the rescue software image. Beginning with ExtremeWare XOS 11.3, the BlackDiamond 8800 family of switches support loading the rescue image to the external compact flash memory card installed in the MSM. For more information see Obtaining the Rescue Image from an External Compact Flash Memory CardBlackDiamond 8800 Family of Switches Only on page 624. Before you begin the recovery process, collect the following information:

IP address, netmask, and gateway for the switch IP address of the TFTP server that contains the ExtremeWare XOS image ExtremeWare XOS image filename (the image has a .xos filename extension) NOTE

The rescue process initializes the primary and secondary images with the ExtremeWare XOS software image. No additional software packages or configuration files are preserved or installed. This process takes a minimum of 7 minutes to complete. To install additional modular software packages, BootROM images (BlackDiamond 10K switch only), and configuration files, see Appendix A, Software Upgrade and Boot Options for more information.

Obtaining the Rescue Image from a TFTP Server


To recover the switch, you must enter the Bootloader and issue a series of commands. To access the Bootloader: 1 Attach a serial cable to the console port of the MSM. 2 Attach the other end of the serial cable to a properly configured terminal or terminal emulator. The terminal settings are:

9600 baud 8 data bits 1 stop bit no parity XON/OFF flow control enabled

3 Reboot the MSM and press the spacebar key on the keyboard of the terminal during the boot up process. NOTE
You must press the spacebar key immediately after a power cycle of the MSM in order to get into the Bootloader application.

As soon as you see the BOOTLOADER -> prompt (BlackDiamond 10K) or the BootRom -> prompt (BlackDiamond 8800 family of switches), release the spacebar. From here, you can begin the recovery process. To obtain the rescue image and recover the switch: 1 Provide the network information (IP address, netmask, and gateway) for the switch using the following command:
configip ipaddress <ip-address>[/<netmask>] gateway <gateway-address>

ExtremeWare XOS 11.3 Concepts Guide

623

Troubleshooting Where the following is true:


ip-addressSpecifies the IP address of the switch netmaskSpecifies the netmask of the switch gateway-addressSpecifies the gateway of the switch

2 Download the ExtremeWare XOS image using the following command:


download image <tftp-address> <filename>

Where the following is true:

tftp-addressSpecifies the IP address of the TFTP server that contains the ExtremeWare

XOS image

filenameSpecifies the filename of the ExtremeWare XOS image

If you attempt to download a non-rescue image, the switch displays an error message and returns you to the BOOTLOADER -> (BlackDiamond 10K switch) or the BootRom -> (BlackDiamond 8800 family of switches) command prompt. After you download the ExtremeWare XOS image file, the switch installs the software and reboots. After the switch reboots, the switch enters an uninitialized state. At this point, configure the switch and save your configuration. In addition, if you previously had modular software packages installed, you must re-install the software packages to each switch partition. For more information about installing software packages, see Appendix A, Software Upgrade and Boot Options. If you are unable to recover the switch with the rescue image, or the switch does not reboot, please contact Extreme Networks Technical Support.

Obtaining the Rescue Image from an External Compact Flash Memory CardBlackDiamond 8800 Family of Switches Only
In addition to recovering the switch using the internal compact flash and the management port, ExtremeWare XOS 11.3 introduces support for loading the rescue image to the external compact flash memory card installed in the MSM. The compact flash memory card must be file allocation table (FAT) formatted. Use a PC with appropriate hardware such as a compact flash reader/writer and follow the manufacturers instructions to access the compact flash card and place the image onto the card. Before you remove or install any hardware, review the Extreme Networks Consolidated XOS Hardware Installation Guide for correct handling instructions. To recover the switch, you must remove power from the switch, install an appropriate compact flash memory card into the MSM, and enter the Bootloader to issue a series of commands. To access the Bootloader: 1 Remove all power cords from the power supplies switch. There should be no power to the switch. 2 Insert the FAT formatted compact flash memory card into the external compact flash slot of the MSM installed in slot 5/A. 3 Remove the MSM installed in slot 6/B. Place the MSM in a safe location and do not re-install it until you finish recovering the switch. 4 Attach a serial cable to the console port of the MSM installed in slot 5/A. Attach the other end of the serial cable to a properly configured terminal or terminal emulator. The terminal settings are:

624

ExtremeWare XOS 11.3 Concepts Guide

Debug Mode

9600 baud 8 data bits 1 stop bit no parity XON/OFF flow control enabled

5 Provide power to the switch by re-inserting the power cords into the power supplies. 6 Immediately press the spacebar until the BootRom -> prompt appears. NOTE
You must press the spacebar key immediately after a power cycle of the MSM in order to get into the Bootloader application.

As soon as you see the BootRom -> prompt, release the spacebar. From here, you can begin the recovery process. To obtain the rescue image that you placed on the compact flash memory card and recover the switch: 1 Download the ExtremeWare XOS image that is already on the external compact flash memory card using the following command:
boot file <filename>

Where the filename specifies the image file for the BlackDiamond 8800 family of switches. 2 At the BootRom -> prompt, press [Enter]. The following message appears:
ok to continue

Type YES to begin the recovery process. This takes a minimum of 7 minutes. 3 After the process runs, the BootRom -> prompt displays the following message:
****press enter to reboot*****

Press [Enter] to reboot the switch. The switch reboots and displays the login prompt. You have successfully completed the setup from the external compact flash memory card. 4 Remove the external compact flash memory card installed in the MSM. After you download the ExtremeWare XOS image file, the switch installs the software and reboots. After the switch reboots, the switch enters an uninitialized state. At this point, configure the switch and save your configuration. In addition, if you previously had modular software packages installed, you must re-install the software packages to each switch partition. For more information about installing software packages, see Appendix A, Software Upgrade and Boot Options. If you are unable to recover the switch with the rescue image, or the switch does not reboot, please contact Extreme Networks Technical Support.

Debug Mode
The Event Management System (EMS) provides a standard way to filter and store messages generated by the switch.With EMS, you must enable debug mode to display debug information. You must have administrator privileges to use these commands. If you do not have administrator privileges, the switch rejects the commands. To enable or disable debug mode for EMS, use the following commands:

ExtremeWare XOS 11.3 Concepts Guide

625

Troubleshooting
enable log debug-mode disable log debug-mode

After debug mode has been enabled, you can configure EMS to capture specific debug information from the switch. Details of EMS can be found in Chapter 8, Status Monitoring and Statistics, on page 181.

Saving Debug Information to the Memory Card


You can save switch data and statistics to either an external memory card installed in the external compact flash slot of an MSM (modular switches only) or the internal memory card that comes preinstalled in the Summit X450 switch. With assistance from Extreme Networks Technical Support personnel, you can configure the switch to capture troubleshooting information, such as a core dump file, to the specified memory card. The switch only generates core dump files in the following situations:

If an ExtremeWare XOS process fails. When forced under the guidance of Extreme Networks Technical Support.

The core dump file contains a snapshot of the process when the error occurred.

NOTE
Use the commands described in this section only under the guidance of Extreme Networks Technical Support personnel to troubleshoot the switch.

This section describes the following topics:


Enabling the Switch to Send Debug Information on page 627 Copying Debug Information on page 627 Managing Files on the External Memory CardModular Switches Only on page 627

Modular Switches OnlyBefore you can enable and save process core dump information to the external memory card, you must install an external memory card into the external compact flash slot of the MSM. For more information about installing an external compact flash memory card, please refer to the Extreme Networks Consolidated XOS Hardware Installation Guide.

Enabling the Switch to Send Debug Information


To enable the switch to save process core dump information to the specified memory card, use the following command:
configure debug coredumps [internal-memory | memorycard | off]

Where the following is true:

internal-memorySpecifies that saving debug information to the internal memory card is enabled. Use this parameter only under the guidance of Extreme Networks Technical Support personnel. (This parameter is available only on the Summit X450 switch.) memorycardSpecifies that saving debug information to the external memory card is enabled. Use this parameter only under the guidance of Extreme Networks Technical Support personnel. (This parameter is available only on modular switches.)

626

ExtremeWare XOS 11.3 Concepts Guide

Saving Debug Information to the Memory Card

offSpecifies that saving debug information to the external memory card is disabled. This is the default behavior.

Copying Debug Information


To save and copy debug information to the specified memory card, use the following command:
save debug tracefiles

Modular Switches OnlyAfter the switch writes a core dump file or other debug information to the external memory card, and before you can view the contents on the card, you must ensure it is safe to remove the card from the external compact flash slot on the MSM. Use the eject memorycard command to prepare the card for removal. After you issue the eject memorycard command, you can manually remove the card from the external compact flash slot on the MSM am read the data on the card. To access and read the data on the card, use a PC with appropriate hardware such as a compact flash reader/writer and follow the manufacturers instructions to access the compact flash card and read the data.

Managing Files on the External Memory CardModular Switches Only


Using a series of commands, you can manage the files stored on your external memory card. For example, you can rename or copy a configuration file, display a comprehensive list of the configuration and policy files, or delete a policy file. The following sections provide a brief overview of the available commands and describe the following topics:

Displaying Files on page 628 Moving or Renaming Files on page 628 Copying Files on page 628 Deleting Files on page 629

For more detailed information about these commands, see Chapter 4, Managing the ExtremeWare XOS Software.

NOTE
Filenames are case-sensitive. For information on filename restrictions, please refer to the specific command in the ExtremeWare XOS Command Reference Guide.

Displaying Files
To display a list of the files stored on your card, including configuration and policy files, use the following command:
ls {memorycard}

ExtremeWare XOS 11.3 Concepts Guide

627

Troubleshooting Output from this command includes the file size, date and time the file was last modified, and the file name.

Moving or Renaming Files


To move or rename an existing configuration or policy file in the system, use the following command:
mv {memorycard} <old-name> {memorycard} <new-name>

Where the following is true:


memorycardSpecifies the removable external compact flash memory card old-nameSpecifies the current name of the configuration or policy file new-nameSpecifies the new name of the configuration or policy file

Configuration files have a .cfg file extension; policy files have a .pol file extension. When you rename a file, make sure the renamed file uses the same file extension as the original file. If you change the file extensions, the file may be unrecognized by the system. For example, if you have an existing configuration file named test.cfg, the new filename must include the .cfg file extension.

Copying Files
The copy function allows you to make a copy of an existing file before you alter or edit the file. By making a copy, you can easily go back to the original file if needed. To copy an existing configuration or policy file on your card, use the following command:
cp {memorycard} <old-name> {memorycard} <new-name>

Where the following is true:


memorycardSpecifies the removable external compact flash memory card old-nameSpecifies the name of the configuration or policy file that you want to copy new-nameSpecifies the name of the copied configuration or policy file

Configuration files have a .cfg file extension; policy files have a .pol file extension. When you copy a configuration or policy file from the system, make sure you specify the appropriate file extension. For example, if you want to copy a policy file, specify the filename and .pol.

Deleting Files
To delete a configuration or policy file from your card, use the following command:
rm {memorycard} <file-name>

Where the following is true:


memorycardSpecifies the removable external compact flash card file-nameSpecifies the name of the configuration or policy file to delete

When you delete a configuration or policy file from the system, make sure you specify the appropriate file extension. For example, if you want to delete a policy file, specify the filename and .pol. After you delete a file, it is unavailable to the system.

628

ExtremeWare XOS 11.3 Concepts Guide

TOP Command

TOP Command
The top command is a UNIX-based command that displays real-time CPU utilization information by process. The output contains a list of the most CPU-intensive tasks and can be sorted by CPU usage, memory usage, and run time. For more detailed information about the top command, please refer to your UNIX documentation.

TFTP Server Requirements


Extreme Networks recommends using a TFTP server that supports blocksize negotiation (as described in RFC 2348, TFTP Blocksize Option), to enable faster file downloads and larger file downloads.

System Health CheckModular Switches Only


This section provides a brief overview the system health check functionality of the following switches:

BlackDiamond 10K BlackDiamond 8800 family of switches (formerly known as Aspen)

For all switches, system health check errors are reported to the syslog. If you see an error, please contact Extreme Networks Technical Support. For more detailed information about the system health checker, including a configuration example, see Chapter 8, Status Monitoring and Statistics.

Overview of the System Health Checker


There are two modes of health checking available on the switch: polling and backplane diagnostic packets. These methods are briefly described for each platform.

BlackDiamond 10K Switch

Polling is always enabled on the system and occurs every 60 seconds by default. The system health checker polls and tracks the ASIC counters that collect correctable and uncorrectable packet memory errors, check sum errors, and parity errors on a per ASIC basis. By reading and processing the registers, the system health check detects and associates faults to specific system ASICs. Backplane diagnostic packets are disabled by default. Once this feature is enabled, the system health checker tests the packet path for a specific I/O module every 6 seconds by default. The Management Switch Fabric Module (MSM) sends and receives diagnostic packets from the I/O module to determine the state and connectivity. (The other I/O modules with backplane diagnostic packets disabled continue polling every 60 seconds by default.)

BlackDiamond 8800 Family of Switches

Polling is always enabled on the system and occurs every 5 seconds by default. The polling value is not a user-configured parameter. The system health check polls the control plane health between

ExtremeWare XOS 11.3 Concepts Guide

629

Troubleshooting MSMs and I/O modules, monitors memory levels on the I/O module, monitors the health of the I/O module, and checks the health of applications and processes running on the I/O module. If the system health checker detects an error, the health checker notifies the MSM.

Backplane diagnostic packets are disabled by default. If you enable this feature, the system health checker tests the data link for a specific I/O module every 5 seconds by default. The MSM sends and receives diagnostic packets from the I/O module to determine the state and connectivity. If you disable backplane diagnostics, the system health checker stops sending backplane diagnostic packets.

Enabling and Disabling Backplane Diagnostic Packets on the Switch


To enable backplane diagnostic packets, use the following command:
enable sys-health-check slot <slot>

BlackDiamond 10K switchBy default, the system health checker tests the packet path every 6 seconds for the specified slot. BlackDiamond 8800 family of switchesBy default, the system health checker tests the data link every 5 seconds for the specified slot. NOTE

Enabling backplane diagnostic packets increases CPU utilization and competes with network traffic for resources.

To disable backplane diagnostic packets, use the following command:


disable sys-health-check slot <slot>

BlackDiamond 10K switchBy default, the system health checker discontinues sending backplane diagnostic packets and returns the polling frequency to 60 seconds on the specified slot. Only polling is enabled. BlackDiamond 8800 family of switchesBy default, the system health checker discontinues sending backplane diagnostic packets to the specified slot. Only polling is enabled.

Configuring Backplane Diagnostic Packets on the Switch


To configure the frequency of sending backplane diagnostic packets, use the following command:
configure sys-health-check interval <interval>

NOTE
Extreme Networks does not recommend configuring an interval of less than the default interval. Doing so can cause excessive CPU utilization.

System Odometer
Each field replaceable component contains a system odometer counter in EEPROM. The show odometers command displays an approximate days of service duration for an individual component since the component was manufactured.

630

ExtremeWare XOS 11.3 Concepts Guide

System Odometer

Monitored Components
On a modular switch, the odometer monitors the following components:

Chassis MSMs I/O modules Power controllers

On the Summit X450 switch, the odometer monitors the following components:

Switch XGN-2xn card

Recorded Statistics
The following odometer statistics are collected by the switch:

Service DaysThe amount of days that the component has been running First Recorded Start DateThe date that the component was powered-up and began running

Depending on the software version running on your switch, the modules installed in your switch, and the type of switch you have, additional or different odometer information may be displayed. The following is sample output from a BlackDiamond 10K switch:
Field Replaceable Units ----------------------Chassis : BD-10808 Slot-1 : G60X Slot-2 : G60X Slot-3 : G60X Slot-4 : Slot-5 : 10G6X Slot-6 : Slot-7 : G60T Slot-8 : 10G6X MSM-A : MSM-1XL MSM-B : MSM-1XL PSUCTRL-1 : PSUCTRL-2 : Service Days ------107 99 74 151 49 184 146 62 172 152 First Recorded Start Date -------------Feb-23-2004 Dec-10-2003 Mar-22-2004 Jan-12-2004 Apr-09-2004 Dec-03-2003 Jan-12-2004 Apr-21-2004 Dec-14-2003 Mar-17-2004

The following is sample output from the BlackDiamond 8800 family of switches:
Field Replaceable Units ------------------------Chassis : BD-8810 Slot-1 : G48T Slot-2 : 10G4X Slot-3 : G48T Slot-4 : G24X Slot-5 : G8X Slot-6 : Service Days ------209 208 219 228 226 139 First Recorded Start Date -------------Dec-07-2004 Dec-07-2004 Nov-02-2004 Oct-26-2004 Oct-19-2004 Dec-07-2004

ExtremeWare XOS 11.3 Concepts Guide

631

Troubleshooting
Slot-7 Slot-8 Slot-9 Slot-10 MSM-A MSM-B PSUCTRL-1 PSUCTRL-2 : : : : : : : : 10G4X 10G4X G48P MSM-G8X 160 133 111 137 209 208 Dec-16-2004 Dec-14-2004 Nov-04-2004 Dec-07-2004 Dec-07-2004 Dec-07-2004

The following is sample output from a Summit X450 switch:


Field Replaceable Units ------------------------Switch : SummitX450-24t XGM-2xn-1 : Service Days ------7 First Recorded Start Date -------------Dec-08-2004

Temperature Operating Range


ExtremeWare XOS has its own temperature operating range of -10 to 50 C. On a modular switch, any module in the switch that is reported outside this range is automatically shut down. ExtremeWare XOS specifically performs a reboot on any MSM that falls outside the expected range. This behavior is expected and not indicative of a problem. If you experience this behavior more than once, please contact Extreme Networks Technical Support. On the Summit X450 switch, if the switch runs outside the expected range, the switch logs an error message, generates a trap, and continues running. No components are shutdown. To verify the state of the switch, use either the show switch or show temperature commands. If the temperature exceeds the maximum limit, the show switch output indicates the switch in an OPERATIONAL (Overheat) mode, and the show temperature output indicates an error state due to overheat.

Corrupted BootROM on the BlackDiamond 8800 Family of Switches


If your default BootROM image becomes corrupted, you can force the MSM to boot from an alternate BootROM image, by inserting a pen into the Alternate (A) and Reset (R) holes on the BlackDiamond 8800 MSM and applying pressure. The alternate BootROM image also prints boot progress indicators, and you can later use this alternate image to re-install a new default BootROM image. Finally, a corrupted compact flash can be recovered from either the Alternate or Default BootROM. For more information, please refer to the Extreme Networks Consolidated XOS Hardware Installation Guide.

632

ExtremeWare XOS 11.3 Concepts Guide

Inserting Powered Devices in the PoE ModuleBlackDiamond 8800 Family of Switches Only

Inserting Powered Devices in the PoE Module BlackDiamond 8800 Family of Switches Only
To reduce the chances of ports fluctuating between powered and non-powered states, newly inserted powered devices (PDs) are not powered when the actual delivered power for the module is within approximately 19 W of the configured inline power budget for that slot. However, actual aggregate power can be delivered up to the configured inline power budget for the slot (for example, when delivered power from ports increases or when the configured inline power budget for the slot is reduced).

Untagged Frames on the 10 Gbps Module BlackDiamond 10K Switch Only


On the BlackDiamond 10K switch, the 10 Gbps module must have the serial number 804405-00-09 or higher to support untagged frames. To display the serial number of the module, issue the show slot <slot_number> command. (All the modules for the BlackDiamond 8800 family of switches support tagged and untagged frames.)

Running MSM Diagnostics from the Bootloader BlackDiamond 10K Switch Only
If you experience problems with your MSM module, or you are unable to use the run diagnostics command, you can enter the Bootloader and issue a series of commands to run diagnostics on the MSM. To access the Bootloader: 1 Attach a serial cable to the console port of the MSM. 2 Attach the other end of the serial cable to a properly configured terminal or terminal emulator.

ExtremeWare XOS 11.3 Concepts Guide

633

Troubleshooting 3 Reboot the MSM and press the spacebar key on the keyboard of the terminal during the boot up process. NOTE
You must press the spacebar key immediately after a power cycle of the MSM in order to get into the Bootloader application.

As soon as you see the BOOTLOADER> prompt, release the key. From here, you can run the diagnostics on the MSM. To run diagnostics on the MSM: 1 Identify the currently running software images by using the show images command. 2 Run diagnostics on the MSM by using the boot [1-4] command. The numbers 1 through 4 correlate to specific images and diagnostics on the MSM:

1XOS primary image 2XOS secondary image 3Diagnostics for image 1 (initiates diagnostics for the primary image) 4Diagnostics for image 2 (initiates diagnostics for the secondary image)

For example, to run diagnostics on the primary image, use the following command:
boot 3

When the test is finished, the MSM reboots and runs the ExtremeWare XOS software.

Contacting Extreme Networks Technical Support


If you have a network issue that you are unable to resolve, contact Extreme Networks technical support. Extreme Networks maintains several Technical Assistance Centers (TACs) around the world to answer networking questions and resolve network problems. You can contact technical support by phone at:

(800) 998-2408 (408) 579-2826

Or by email at:

support@extremenetworks.com

You can also visit the support website at: http://www.extremenetworks.com/services/resources/ From the support website, you can download software updates (requires a service contract) and documentation (including a .pdf version of this manual).

634

ExtremeWare XOS 11.3 Concepts Guide

CNA Agent

The entire CNA software package consists of multiple parts. The Extreme Networks devices run only the CNA Agent. You must have the entire package; you cannot use the CNA Agent without the CNA software from Avaya. The user interface is a combination of a Java applet hosted from the CNA Server and a Command Line Interface (CLI). You configure and manage the CNA Agent using the CLI.

NOTE
Contact your Avaya representative to obtain the rest of the CNA software and the associated documentation.

If you are using Avaya CNA solutions, you download a separate software module to add the CNA Agent to ExtremeWare XOS 11.2 software; this software module runs on all platforms.

NOTE
You must download and install the SSH software module prior to downloading and installing the CNA Agent software module.

This appendix covers the following topics regarding the CNA Agent:

Overview on page 635 Downloading the CNA Agent Software Module on page 636 Running the Tests on page 636 Configuring the CNA Agent on page 637

Overview
The CNA Agent accepts requests (from the CNA Server) to run tests for measuring and verifying network performance, and the CNA Agent reports back the results to the CNA Server. The CNA Agent functions as a UDP service accepting authenticated requests from and returning test results to the CNA Server. You download the CNA Agent software as a separate software module onto your device. If you do not have it already, you must also download the separate SSH software module, which contains SSL. Once you enable the software, the CNA Agent registers with the CNA Server and exchanges openSSL keys, using a 128-bit encryption key. All following communication between the CNA Agent and the CNA Server is encrypted. The CNA Server communicates with the CNA Agent to request specific tests and to schedule those tests. The CNA Agent runs the requested tests and sends the results back to the CNA Server. The CNA Agent can register with one CNA Server, talk to one CNA Server at a time, and respond to only one test request at a time. The other test requests are queued up.

ExtremeWare XOS 11.3 Concepts Guide

635

CNA Agent The system sends messages to the syslog for each new connection, the status of that connection, received test requests, and reported test results. Also EMS messages are generated after successful registration.

RedundancyBlackDiamond 10K Switch and BlackDiamond 8800 Family of Switches Only


The CNA Agent software offers resiliency and redundancy on the BlackDiamond 10K switch and the BlackDiamond 8800 family of switches. On systems with a primary and a backup MSM, the CNA Agent software fails over to the backup MSM when the primary MSM goes down. Also, the MSM restarts the CNA Agent software if the CNA Agent goes down or gets into a looped condition.

Downloading the CNA Agent Software Module


To use the CNA Agent functionality, you download the separate Extreme Networks software module (cna.xmod) following the instructions outlined in Appendix A. Because the CNA Agent software uses openSSL, you must first download the separate Extreme Networks SSH software module that contains SSL.

NOTE
You must download the SSH module prior to downloading the CNA module.

If you attempt to download the CNA software module and you have not already downloaded the SSH software module, the system returns an error.

Running the Tests


The CNA Server requests the CNA Agent to run a specific test, and the CNA Agent runs the test and reports the results back to the CNA Server. The CNA Agent can run the following tests:

TracerouteMeasures per-hop round-trip delays to a target IP address by sending a sequence of hop-limited UPD messages, each with a time-to-live (TTL) value that is one greater than that of the preceding message. RTPEmulates VoIP traffic to measure delay, packet loss and jitter to another CNA Agent by sending a simulated RTP stream that is echoed back. PingSends an ICMP echo message to a target IP address and reports whether or not a response was returned. TCPconnectAttempts to establish a TCP connection to a specified port at a target IP address and reports whether the attempt succeeded or failed. MergeUsed by CNA software to identify a single device with multiple IP addresses and to merge its multiple appearances into one in the network topology map.

636

ExtremeWare XOS 11.3 Concepts Guide

Configuring the CNA Agent The CNA Agent starts the specified test within 100 ms once it receives an authenticated and correctly formatted test request from the CNA Server. The CNA Agent sends the test results to the CNA Server within 100 ms of test completion.

Configuring the CNA Agent


To run the tests, configure the following:

Enable the CNA Agent. Configure the IP address the CNA Agent uses to communicate with the CNA Server. Configure the VLAN interface for the CNA Server

This step is optional. By default, the CNA Server uses the primary IP address on the switchs Default VLAN. This step is optional.

Clear the counters.

Display the test results.

All these configurations are saved when you issue the save configuration command.

Enabling the CNA Agent


You enable the CNA Agent (test plug) by issuing the following command:
enable cna-testplug

Once you enable the CNA Agent, you register the CNA Agent with the CNA Server, and the CNA Agent performs the requested network tests and reports the results. To disable the CNA Agent, use the following command:
disable cna-testplug

Connecting to the CNA Server


After you enable the CNA Agent, you must configure this parameter to allow the CNA Agent to register with the CNA Server. Use the following command: configure cna-testplug scheduler ipaddress <ip_address> You enter the IP address of the CNA Server. (With ExtremeWare XOS software version 11.2, this must be an IPv4 address.) Once you configure the IP address for the CNA server, the CNA Agent and the CNA Server exchange SSL keys and establish encryption. After successful registration, you can connect with more than one CNA Server, in which case you share the encryption key you negotiated with your initial CNA Server connection. At this time, the system establishes the socket connection to the CNA Server using this IP address. The CNA Agent listens for instructions for the testing from this IP address.

ExtremeWare XOS 11.3 Concepts Guide

637

CNA Agent

Configuring the Interface


By default, the Extreme Networks device uses the default VLAN as the interface that the CNA Agent (test plug) uses to receive test requests, conduct the tests, and send the results to the CNA Server. (The default VLAN belongs to the default virtual router: VR-Default). If you want to change this interface, issue the following command:
configure cna-testplug vlan <vlan_name>

If the VLAN has more than one IP address, the system uses the primary IP address.

NOTE
Extreme Networks recommends that you put IP telephones on the same virtual router.

Clearing the Counters


You clear the CNA Agent (test plug) counters by issuing the following command:
clear cna-testplug counters

This command clears the CNA Agent counters on the Extreme Networks devices and resets those counters to zero. You can also issue the clear counters command, which clears all the counters on the device including those associated with the CNA Agent.

Displaying CNA Agent Information


You display summaries of completed tests as well as the CNA Server (scheduler) connections and status for the CNA Agent (test plug) by issuing the following command:
enable cna-testplug

The following shows sample output from this command:


show cna-testplug HW Name: BlackDiamond 10808 Firmware Version: 11.3.0.4 Interface VLAN: "Default" on Virtual router "VR-Default" IP address of the Interface: 10.203.135.61 CNA Testplug version: 3.0.1 Interface version with Scheduler:17 Admin: Enabled Status: Registered Errors: 29846 Total tests received: 58338 Scheduler (SBC): 10.203.128.123: 20000: Listening ports --Test requests(from ANS): 50000 --RTP test requests(from test plugs): 50001

638

ExtremeWare XOS 11.3 Concepts Guide

Configuring the CNA Agent


--RTP and Traceroute responses(from test plugs): 50015 Last Test: Ping to 10.203.135.61 Result Last Test: ping results: rtt: 2.292000, loss: 0.000000 Results: TEST COUNT FAILED -------------Traceroute 65489 0 RTP 51403 0 Ping 101549 0 Tcpconnect 36455 0 Merge 50 0

NOTE
Adaptive Networking Software (ANS) runs on the CNA Server.

Troubleshooting
If the CNA Agent is not able to register with the CNA Server, check the following items:

Ensure the time on the Extreme Networks device is set correctly.


To display the time, issue the show switch command. To reset the time, issue the configure time <month> <day> <year> <hour> <min> <sec> command.

Ensure that the openSSL certificate on the CNA Server has not expired.

ExtremeWare XOS 11.3 Concepts Guide

639

CNA Agent

640

ExtremeWare XOS 11.3 Concepts Guide

Supported Protocols, MIBs, and Standards

This appendix provides a list of software standards and protocols supported by ExtremeWare XOS. This appendix includes the following topics:

General Routing and Switching on page 641 Virtual LANS (VLANs) on page 642 Link Fault Signal (LFS) on page 642 Quality of Service (QoS) on page 642 Routing Information Protocol (RIP) on page 642 Routing Information Protocol for IPv6 (RIPng) on page 642 Open Shortest Path First (OSPF) on page 642 Open Shortest Path First for IPv6 (OSPFv3) on page 642 Border Gateway Protocol 4 (BGP4) on page 642 Power over Ethernet (PoE) on page 642 IP Multicast on page 643 Management - SNMP & MIBs on page 643 Management - Other on page 644 Security on page 644 DiffServ - Standards and MIBs on page 644

General Routing and Switching RFC 1812 Requirements for IP Version 4 Routers RFC 1519 An Architecture for IP Address Allocation with CIDR RFC 1256 ICMP Router Discovery Messages RFC 783 TFTP Protocol (revision 2) RFC 951 Bootstrap Protocol RFC 1542 Clarifications and Extensions for the Bootstrap Protocol RFC 2131 Dynamic Host Configuration Protocol RFC 1122 Requirements for Internet Hosts Communication Layers RFC 768 User Datagram Protocol RFC 791 Internet Protocol RFC 792 Internet Control Message Protocol RFC 793 Transmission Control Protocol RFC 826 Ethernet Address Resolution Protocol: Or converting network protocol addresses to 48.bit Ethernet address for transmission on Ethernet hardware RFC 2402 IP Authentication Header RFC 2460 Internet Protocol, Version 6 (IPv6) Specification RFC 2461 Neighbor Discovery for IP Version 6 (IPv6) RFC 2338 Virtual Router Redundancy Protocol Draft VRRP spec v2.06 (minor modifications to RFC 2338) RFC 3619 Ethernet Automatic Protection Switching (EAPS) Version 1 Ethernet Automatic Protection Switching (EAPS) Version 2 Extreme Standby Router Protocol (ESRP) IEEE 802.1ab Link Layer Discovery Protocol (LLDP) IEEE 802.1D-1998 Spanning Tree Protocol IEEE 802.1W - 2001 Rapid Spanning Tree Protocol Definitions of managed objects for bridges with rapid spanning tree protocol Draft-ietf-bridge-rstpm.b-03.txt IEEE 802.1Q - 1998 Virtual Bridged Local Area Networks

ExtremeWare XOS 11.3 Concepts Guide

641

Supported Protocols, MIBs, and Standards

Virtual LANS (VLANs) IEEE 802.1Q VLAN Tagging IEEE 802.3ad Static ConfigPort-based VLANs Protocol-sensitive VLANs Multiple STP domains per VLAN Virtual MANs

Link Fault Signal (LFS) IEEE 802.3ae-2002

Quality of Service (QoS) IEEE 802.1D -1998 (802.1p) Packet Priority RFC 2474 Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers RFC 2598 An Expedited Forwarding PHB Bi-directional Rate Shaping RFC 2597 Assured Forwarding PHB Group RFC 2475 An Architecture for Differentiated Service Layer 1-4, Layer 7 Policy-Based Mapping

Routing Information Protocol (RIP) RFC 1058 Routing Information Protocol RFC 2453 RIP Version 2

Routing Information Protocol for IPv6 (RIPng) RFC 2080 RIPng for IPv6

Open Shortest Path First (OSPF) RFC 2328 OSPF Version 2 RFC 1587 The OSPF NSSA Option RFC 1765 OSPF Database Overflow RFC 2370 The OSPF Opaque LSA Option RFC 3623 Graceful OSPF Restart

Open Shortest Path First for IPv6 (OSPFv3) RFC 2740 OSPF for IPv6 OSPF-v3 SNMP MIB access: draft-ietf-ospfv3-mib-08 RFC 1765 OSPF Database Overflow

Border Gateway Protocol 4 (BGP4) RFC 1771 A Border Gateway Protocol 4 (BGP-4) RFC 1965 Autonomous System Confederations for BGP RFC 2796 BGP Route Reflection - An Alternative to Full Mesh IBGP RFC 1657 Definitions of Managed Objects for the Fourth Version of the Border Gateway Protocol (BGP-4) Using SMIv2 RFC 1997 BGP Communities Attribute RFC 1745 BGP4/IDRP for IP---OSPF Interaction RFC 2385 Protection of BGP Sessions via the TCP MD5 Signature Option RFC 2439 BGP Route Flap Dampening MBGP

Power over Ethernet (PoE) RFC 3621 Power Ethernet MIB IEEE 802.3af standard

642

ExtremeWare XOS 11.3 Concepts Guide

IP Multicast RFC 2362 Protocol Independent Multicast-Sparse Mode (PIM-SM): Protocol Specification PIM-DM Draft IETF PIM Dense Mode v2-dm-03 PIM MIB draft-ietf-pim-mib-v2-01.txt RFC 1112 Host extensions for IP multicasting RFC 2236 Internet Group Management Protocol, Version 2 IGMP Snooping with Configurable Router Registration Forwarding RFC 3376 Internet Group Management Protocol, Version 3

Management - SNMP & MIBs RFC 1157 Simple Network Management Protocol (SNMP) RFC 1215 Convention for defining traps for use with the SNMP RFC 1901 Introduction to Community-based SNMPv2 RFC 1902 Structure of Management Information for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1903 Textual Conventions for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1904 Conformance Statements for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1905 Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1906 Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1907 Management Information Base for Version 2 of the Simple Network Management Protocol (SNMPv2) RFC 1908 Coexistence between Version 1 and Version 2 of the Internet-standard Network Management Framework RFC 2570 Introduction and Applicability Statements for Internet-Standard Management Framework RFC 2571 An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks RFC 1757 Remote Network Monitoring Management Information Base RFC 2021 Remote Network Monitoring Management Information Base Version 2 using SMIv2 RFC 2572 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP) RFC 2573 Simple Network Management Protocol (SNMP) Applications RFC 2574 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3) RFC 2575 View-based Access Control Model (VACM) for the Simple Network Management Protocol ExtremeWare vendor MIBs (includes statistics, STP, CPU monitoring, EAPS, ACL, CLEAR-Flow, and others) EAPS MIB supports get functions RFC 1212 Concise MIB definitions RFC 1213 Management Information Base for Network Management of TCP/IP-based internets: MIB-II RFC 2233 Evolution of the Interfaces Group of MIB-II RFC 1724 RIP Version 2 MIB Extension RFC 1850 OSPF Version 2 Management Information Base Management Information Base for OSPFv3 based on draft-ietf-ospf-ospfv3-mib-08.txt RFC 2465 Management Information Base for IP Version 6: Textual Conventions Group RFC 2466 Management Information Base for IP Version 6: ICMPv6 Group RFC 1493 Definitions of Managed Objects for Bridges BGP4-V2-MIB draft-ietf-idr-bgp4-mibv2-02.txt RFC 2668 Definitions of Managed Objects for IEEE 802.3 Medium Attachment Units (MAUs) RFC 2787 Definitions of Managed Objects for the Virtual Router Redundancy Protocol RFC 2737 Entity MIB (Version 2) LLDP Basic MIB LLDP-EXT-DOT1-MIB LLDP-EXT-DOT2-MIB

ExtremeWare XOS 11.3 Concepts Guide

643

Supported Protocols, MIBs, and Standards

Management - Other RFC 854 Telnet Protocol Specification Telnet client and server Secure Shell 2 (SSH2) client and server Secure Copy 2 (SCP2) client and server Configuration logging Multiple Images, Multiple Configs BSD System Logging Protocol (SYSLOG), with Multiple Syslog Servers Local Messages (criticals stored across reboots) RFC 2030 Simple Network Time Protocol (SNTP) Version 4 for IPv4 and OSI

Security Routing protocol authentication RFC 1492 An Access Control Protocol, Sometimes Called TACACS Secure Shell (SSHv2) & Secure Copy (SCPv2) with encryption/authentication Secure Socket Layer (SSL) IEEE 802.1x Port Based Network Access Control RFC 2138 Remote Authentication Dial In User Service (RADIUS) RFC 2139 RADIUS Accounting Access Control Lists (ACLs) RFC 2406 IP Encapsulating Security Payload (ESP)

DiffServ - Standards and MIBs RFC 2474 Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers RFC 2475 An Architecture for Differentiated Services RFC 2597 Assured Forwarding PHB Group RFC 2598 An Expedited Forwarding PHB

644

ExtremeWare XOS 11.3 Concepts Guide

Glossary
A
AAA Authentication, authorization, and accounting. A system to control which computer resources specific users can access and to keep track of the activity of specific users over the network. Area border router. In OSPF, an ABR has interfaces in multiple areas, and it is responsible for exchanging summary advertisements with other ABRs. Access Control List. ACLs are a mechanism for filtering packets at the hardware level. Packets can be classified by characteristics such as the source or destination MAC, IP addresses, IP type, or QoS queue. Once classified, the packets can be forwarded, counted, queued, or dropped. In Extreme Networks XOS software, you configure ACLs by creating a file, called a policy file (with a .pol file extension). The system parses the policy file and loads the ACL into the hardware. In RSTP, the alternate port supplies an alternate path to the root bridge and the root port. Access point. In wireless technology, access points are the devices that connect to the regular wired network and forward and receive the radio signals that transmit wireless data. In OSPF, an area is a logical set of segments connected by routers. The topology within an area is hidden from the rest of the AS. Address Resolution Protocol. ARP is part of the TCP/IP suite used to dynamically associate a devices physical address (MAC address) with its logical address (IP address). The system broadcasts an ARP request, containing the IP address, and the device with that IP address sends back its MAC address so that traffic can be transmitted. Autonomoous system. In OSPF, an AS is a connected segment of a network topology that consists of a collection of subnetworks (with hosts attached) interconnected by a set of routes. The subnetworks and the routers are expected to be under the control of a single administration. Within an AS, routers may use one or more interior routing protocols and sometimes several sets of metrics. An AS is expected to present to other ASs an appearance of a coherent interior routing plan and a consistent picture of the destinations reachable through the AS. An AS is identified by a unique 16-bit number. Autonomous system border router. In OSPF, an ASBR acts as a gateway between OSPF and other routing protocols or other ASs.

ABR

ACL

alternate port AP

area ARP

AS

ASBR

ExtremeWare XOS 11.3 Concepts Guide

645

Glossary

A (Continued)
autobind In STP, autobind, when enabled, automatically adds or removes ports from the STPD. If ports are added to the carrier VLAN, the member ports of the VLAN are automatically added to the STPD. If ports are removed from the carrier VLAN, those ports are also removed from the STPD. As set forth in IEEE 802.3u, autonegotation allows each port on the switchin partnership with its link partnerto select the highest speed between 10 Mbps and 100 Mbps and the best duplex mode.

autonegotation

B
backbone area In OSPF, a network that has more than one area must have a backbone area, configured as 0.0.0.0. All areas in an AS must connect to the backbone area. In RSTP, the backup port supports the designated port on the same attached LAN segment. Backup ports exist only when the bridge is connected as a self-loop or to a shared media segment. In VRRP, the backup router is any VRRP router in the VRRP virtual router that is not elected as the master. The backup router is available to assume forwarding responsibility if the master becomes unavailable. Backup designated router. In OSPF, the system elects a DR and a BDR. The BDR smooths the transition to the DR, and each multiaccess network has a BDR. The BDR is adjacent to all routers on the network and becomes the DR when the previous DR fails. The period of disruption in transit traffic lasts only as long as it takes to flood the new LSAs (which announce the new DR). The BDR is elected by the protocol; each hello packet has a field that specifies the BDR for the network. Border Gateway Protocol. BGP is a router protocol in the IP suite designed to exchange network reachability information with BGP systems in other ASs. You use a fully meshed configuration with BGP. BGP provides routing updates that include a network number, a list of ASs that the routing information passed through, and a list of other path attributes. BGP works with cost metrics to choose the best available path; it sends updated router information only when one host has detected a change, and only the affected part of the routing table is sent. BGP communicates within one AS using Interior BGP (IBGP) because BGP does not work well with IGP. The routers inside the AS thus maintain two routing tables: one for the IGP and one for IBGP. BGP uses exterior BGP (EBGP) between different ASs. This is a hardware-based technology that allows you to manage bandwidth on Layer 2 and Layer 3 traffic flowing to each port on the switch and to the backplane, per physical port on the I/O module. The parameters differ across platforms and modules.

backup port

backup router

BDR

BGP

bi-directional rate shaping

ExtremeWare XOS 11.3 Concepts Guide

646

B (Continued)
blackhole In the Extreme Networks implementation, you can configure the switch so that traffic is silently dropped. Although this traffic appears as received, it does not appear as transmitted (because it is dropped). Bootstrap Protocol. BOOTP is an Internet protocol used by a diskless workstation to discover its own IP address, the IP address of a BOOTP server on the network, and a file that can be loaded into memory to boot the machine. Using BOOTP, a workstation can boot without a hard or floppy disk drive. Bridge protocol data unit. In STP, a BPDU is a packet that initiates communication between devices. BPDU packets contain information on ports, addresses, priorities, and costs and ensure that the data ends up where it was intended to go. BPDU messages are exchanged across bridges to detect loops in a network topology. The loops are then removed by shutting down selected bridge interfaces and placing redundant switch ports in a backup, or blocked, state. In conventional networking terms, bridging is a Layer 2 function that passes frames between two network segments; these segments have a common network layer address. The bridged frames pass only to those segments connected at a Layer 2 level, which is called a broadcast domain (or VLAN). You must use Layer 3 routing to pass frames between broadcast domains (VLANs). In wireless technology, bridging refers to forwarding and receiving data between radio interfaces on APs or between clients on the same radio. So, bridged traffic can be forwarded from one AP to another AP without having to pass through the switch on the wired network. broadcast A broadcast message is forwarded to all devices within a VLAN, which is also known as a broadcast domain. The broadcast domain, or VLAN, exists at a Layer 2 level; you must use Layer 3 routing to communicate between broadcast domains, or VLANs. Thus, broadcast messages do not leave the VLAN. Broadcast messages are identified by a broadcast address.

BOOTP

BPDU

bridge

C
carrier VLAN In STP, carrier VLANs define the scope of the STPD, including the physical and logical ports that belong to the STPD as well as the 802.1Q tags used to transport EMISTP- or PVST+-encapsulated BPDUs. Only one carrier VLAN can exist in any given STPD. Checkpointing is the process of copying the active state configurations from the primary MSM to the backup MSM on modular switches. Classless Inter-Domain Routing. CIDR is a way to allocate and specify the Internet addresses used in interdomain routing more flexibly than with the original system of IP address classes. This address aggregation scheme uses supernet addresses to represent multiple IP destinations. Rather than advertise a separate route for each destination, a router uses a supernet address to advertise a single route representing all destinations. RIP does not support CIDR; BGP and OSPF support CIDR.

checkpointing CIDR

ExtremeWare XOS 11.3 Concepts Guide

647

Glossary

C (Continued)
CLEAR-Flow CLEAR-Flow allows you to specify certain types of traffic to perform configured actions on. You can configure the switch to take an immediate, preconfigured action to the specified traffic or to send a copy of the traffic to a management station for analysis. CLEAR-Flow is an extension to ACLs, so you must be familiar with ACL policy files to apply CLEAR-Flow. Command line interface. You use the CLI to monitor and manage the switch. In BGP, a cluster is formed within an AS by a route reflector and its client routers. Converged Network Analyzer. This application suite, available from Avaya, allows the server to determine the best possible network path. The CNA Agent is a software piece of the entire CNA application that you install on Extreme Networks devices. You use the CNA Agent software only if you are using the Avaya CNA solution, and the CNA Agent cannot function unless you also obtain the rest of the CNA application from Avaya. Combination port. On some Extreme Networks devices (such as the Summit X450 switch), certain ports can be used as either copper or fiber ports. In EAPS, the common link is the physical link between the controller and partner nodes in a network where multiple EAPS share a common link between domains. In EAPS, the controller node is that end of the common line that is responsible for blocking ports if the common link fails, thereby preventing a superloop. In EAPS, the control VLAN is a VLAN that sends and receives EAPS messages. You must configure one control VLAN for each EAPS domain. Cyclic redundancy check. This simple checksum is designed to detect transmission errors. A decoder calculates the CRC for the received data and compares it to the CRC that the encoder calculated, which is appended to the data. A mismatch indicates that the data was corrupted in transit. Cyclic redundancy check error. This is an error condition in which the data failed a checksum test used to trap transmission errors. These errors can indicate problems anywhere in the transmission path.

CLI cluster CNA

combo port

common link

controller node

control VLAN

CRC

CRC error

D
DA DAD Destination address. The DA is the IP or MAC address of the device that is to receive the packet. Duplicate Address Detection. IPv6 automatically uses this process to ensure that no duplicate IP addresses exist.

ExtremeWare XOS 11.3 Concepts Guide

648

D (Continued)
default encapsulation mode In STP, default encapsulation allows you to specify the type of BPDU encapsulation to use for all ports added to a given STPD, not just to one individual port. The encapsulation modes are:

802.1dThis mode is used for backward compatibility with previous STP versions and for compatibility with third-party switches using IEEE standard 802.1d. EMISTPExtreme Multiple Instance Spanning Tree Protocol (EMISTP) mode is an extension of STP that allows a physical port to belong to multiple STPDs by assigning the port to multiple VLANs. PVST+This mode implements PVST+ in compatibility with thirdparty switches running this version of STP.

designated port

In STP, the designated port provides the shortest path connection to the root bridge for the attached LAN segment. Each LAN segment has only one designated port. The Device Manager is an Extreme Networks-proprietary process that runs on every node and is responsible for monitoring and controlling all of the devices in the system. The Device Manager is useful for system redundancy. Dont fragment bit. This is the dont fragment bit carried in the flags field of the IP header that indicates that the packet should not be fragmented. The remote host will return ICMP notifications if the packet had to be split anyway, and these are used in MTU discovery. Dynamic Host Configuration Protocol. DHCP allows network administrators to centrally manage and automate the assignment of IP addresses on the corporate network. DHCP sends a new IP address when a computer is plugged into a different place in the network. The protocol supports static or dynamic IP addresses and can dynamically reconfigure networks in which there are more computers than there are available IP addresses. Differentiated Services. Defined in RFC 2474 and 2475, DiffServ is an architecture for implementing scalable service differentiation in the Internet. Each IP header has a DiffServ (DS) field, formerly known as the Type of Service (TOS) field. The value in this field defines the QoS priority the packet will have throughout the network by dictating the forwarding treatment given to the packet at each node. DiffServ is a flexible architecture that allows for either end-to-end QoS or intradomain QoS by implementing complex classification and mapping functions at the network boundary or access points. In the Extreme Networks implementation, you can configure the desired QoS by replacing or mapping the values in the DS field to egress queues that are assigned varying priorities and bandwidths. Denial of service attacks occur when a critical network or computing resource is overwhelmed so that legitimate requests for service cannot succeed. In its simplest form, a DoS attack is indistinguishable from normal heavy traffic. ExtremeWare XOS software has configurable parameters that allow you to defeat DoS attacks.

Device Manager

DF

DHCP

DiffServ

DoS attack

ExtremeWare XOS 11.3 Concepts Guide

649

Glossary

D (Continued)
DR Designated router. In OSPF, the DR generates an LSA for the multiaccess network and has other special responsibilities in the running of the protocol. The DR is elected by the OSPF protocol. These are packets that the switch received but does not transmit.

dropped packets

E
EAPS Extreme Automatic Protection Switching. EAPS is an Extreme Networks-proprietary protocol that prevents looping Layer 2 of the network. This feature is discussed in RFC 3619. An EAPS domain consists of a series of switches, or nodes, that comprise a single ring in a network. An EAPS domain consists of a master node and transit nodes. The master node consists of one primary and one secondary port. EAPS operates by declaring an EAPS domain on a single ring. Each common link in the EAPS network must have a unique link ID. The controller and partner shared ports belonging to the same common link must have matching link IDs, and not other instance in the network should have that link ID. Exterior Border Gateway Protocol. EBGP is a protocol in the IP suite designed to exchange network reachability information with BGP systems in other ASs. EBGP works between different ASs. Equal Cost Multi Paths. In OSPF, this routing algorithm distributes network traffic across multiple high-bandwidth links to increase performance. The Extreme Networks OSPF implementation supports multiple equal cost paths between points and divides traffic evenly among the available paths. As many as four links may be involved in an ECMP link, and traffic is shared on the basis of IP source/ destination address session. In STP, edge ports connect to non-STP devices such as routers, endstations, and other hosts. Extreme Discovery Protocol. EDP is a protocol used to gather information about neighbor Extreme Networks switches. Extreme Networks switches use EDP to exchange topology information. Electrically erasable programmable read-only memory. EEPROM is a memory that can be electronically programmed and erased but does not require a power source to retain data. Exterior Gateway Protocol. EGP is an Internet routing protocol for exchanging reachability information between routers in different ASs. BGP is a more recent protocol that accomplishes this task. In ESRP, this is a user-defined criteria to determine how the master and slave interact. The election algorithm also determines which device becomes the master or slave and how ESRP makes those decisions.

EAPS domain

EAPS link ID

EBGP

ECMP

edge ports EDP

EEPROM

EGP

election algorithm

ExtremeWare XOS 11.3 Concepts Guide

650

E (Continued)
ELRP EMISTP Extreme Loop Recovery Protocol. ELRP is an Extreme Networksproprietary protocol that allows you to detect Layer 2 loops. Extreme Multiple Instance Spanning Tree Protocol. This Extreme Networks-proprietary protocol uses a unique encapsulation method for STP messages that allows a physical port to belong to multiple STPDs. Event Management System. This Extreme Networks-proprietary system saves, displays, and filters events, which are defined as any occurrences on a switch that generate a log message or require action. Using STP, you can configure ports within an STPD to accept specific BPDU encapsulations. The three encapsulation modes are:

EMS

encapsulation mode

802.1DThis mode is used for backward compatibility with previous STP versions and for compatibility with third-party switches using IEEE standard 802.1D. EMISTPExtreme Multiple Instance Spanning Tree Protocol mode is an extension of STP that allows a physical port to belong to multiple STPDs by assigning the port to multiple VLANs. PVST+This mode implements PVST+ in compatibility with thirdparty switches running this version of STP.

EPICenter ESRP

EPICenter is an Extreme Networks-proprietary graphical user interface (GUI) network management system. Extreme Standby Router Protocol. ESRP is an Extreme Networksproprietary protocol that provides redundant Layer 2 and routing services to users. This is an Extreme Networks device that is not running ESRP itself but that is connected on a network with other Extreme Networks switches that are running ESRP. These ESRP-aware devices also fail over. An ESRP domain allows multiple VLANs to be protected under a single logical entity. An ESRP domain consists of one domain-master VLAN and zero or more domain-member VLANs. An ESRP-enabled device is an Extreme Networks switch with an ESRP domain and ESRP enabled. ESRP-enabled switches include the ESRP master and slave switches. An ESRP group runs multiple instances of ESRP within the same VLAN (or broadcast domain). To provide redundancy at each tier, use a pair of ESRP switches on the group. You enable ESRP on a per domain basis; each time you enable ESRP is an ESRP instance. A VLAN that is part of an ESRP domain, with ESRP enabled, is an ESRP VLAN.

ESRP-aware device

ESRP domain

ESRP-enabled device

ESRP groups

ESRP instance ESRP VLAN

ExtremeWare XOS 11.3 Concepts Guide

651

Glossary

E (Continued)
Ethernet This is the IEEE 802.3 networking standard that uses carrier sense multiple access with collision detection (CSMA/CD). An Ethernet device that wants to transmit first checks the channel for a carrier, and if no carrier is sensed within a period of time, the device transmits. If two devices transmit simultaneously, a collision occurs. This collision is detected by all transmitting devices, which subsequently delay their retransmissions for a random period. Ethernet runs at speeds from 10 Mbps to 10 Gbps on full duplex. ESRP extended mode supports and is compatible only with switches running ExtremeWare XOS software exclusively.

extended mode

F
Fast Convergence In EAPS, Fast Convergence allows convergence in less than 50 milliseconds. You configure this parameter for the entire switch, not by EAPS domain. Forwarding database. The switch maintains a database of all MAC address received on all of its ports and uses this information to decide whether a frame should be forwarded or filtered. Each FDB entry consists of the MAC address of the sending device, an identifier for the port on which the frame was received, and an identifier for the VLAN to which the device belongs. Frames destined for devices that are not currently in the FDB are flooded to all members of the VLAN. For some types of entries, you configure the time it takes for the specific entry to age out of the FDB. Forwarding Information Base. On the BlackDiamond 8800 family of switches and the Summit X450 switch, the Layer 3 routing table is referred to as the FIB. This is the unit of transmission at the data link layer. The frame contains the header and trailer information required by the physical medium of transmission. This is the communication mode in which a device simultaneously sends and receives over the same link, doubling the bandwidth. Thus, a full-duplex 100 Mbps connection has a bandwidth of 200 Mbps, and so forth. A device either automatically adjusts its duplex mode to match that of a connecting device or you can configure the duplex mode; all devices at 1 Gbps or higher run only in full-duplex mode.

FDB

FIB

frame

full-duplex

G
GBIC Gigabit Interface Connector. These devices, available in a variety of fiber modes and physical shapes, provide the physical interface to a gigabit Ethernet connection. This is the networking standard for transmitting data at 1000 Mbps or 1 Gbps. Devices can transmit at multiples of gigabit Ethernet as well.

Gigabit Ethernet

ExtremeWare XOS 11.3 Concepts Guide

652

H
HA Host Attach. In ExtremeWare XOS software, HA is part of ESRP that allows you to connect active hosts directly to an ESRP switch; it allows configured ports to continue Layer 2 forwarding regardless of their ESRP status. This is the communication mode in which a device can either send or receive data, but not simultaneously. (Devices at 1 Gbps or higher do not run in half-duplex mode; they run only in full-duplex mode.) This is control information (such as originating and destination stations, priority, error checking, and so forth) added in front of the data when encapsulating the data for network transmission. In the Extreme Networks implementation on modular switches, hitless failover means that designated configurations survive a change of primacy between the two MSMs with all details intact. Thus, those features run seamlessly during and after control of the system changes from one MSM to another.

half-duplex

header

hitless failover

I
IBGP ICMP Interior Border Gateway Protocol. IBGP is the BGP version used within an AS. Internet Control Message Protocol. ICMP is the part of the TCP/IP protocol that allows generation of error messages, test packets, and operating messages. For example, the ping command allows you to send ICMP echo messages to a remote IP device to test for connectivity. ICMP also supports traceroute, which identifies intermediate hops between a given source and destination. Institute of Electrical and Electronic Engineers. This technical professional society fosters the development of standards that often become national and international standards. The organization publishes a number of journals and has many local chapters and several large societies in special areas. Internet Engineering Task Force. The IETF is a large, open, international community of network designers, operators, vendors, and researchers concerned with the evolution of the Internet architecture and the smooth operation of the Internet. The technical work of the IETF is done in working groups, which are organized by topic. Internet Group Management Protocol. Hosts use IGMP to inform local routers of their membership in multicast groups. Multicasting allows one computer on the Internet to send content to multiple other computers that have identified themselves as interested in receiving the originating computer's content. When all hosts leave a group, the router no longer forwards packets that arrive for the multicast group.

IEEE

IETF

IGMP

ExtremeWare XOS 11.3 Concepts Guide

653

Glossary

I (Continued)
IGMP snooping This provides a method for intelligently forwarding multicast packets within a Layer 2 broadcast domain. By snooping the IGMP registration information, the device forms a distribution list that determines which endstations receive packets with a specific multicast address. Layer 2 switches listen for IGMP messages and build mapping tables and associated forwarding filters. IGMP snooping also reduces IGMP protocol traffic. Interior Gateway Protocol. IGP refers to any protocol used to exchange routing information within an AS. Examples of Internet IGPs include RIP and OSPF. According to IEEE 802.3 af, inline power refers to providing an AC or DC power source through the same cable as the data travels. It allows phones and network devices to be placed in locations that are not near AC outlets. Most standard telephones use inline power. Internet Protocol. The communications protocol underlying the Internet, IP allows large, geographically diverse networks of computers to communicate with each other quickly and economically over a variety of physical links; it is part of the TCP/IP suite of protocols. IP is the Layer 3, or network layer, protocol that contains addressing and control information that allows packets to be routed. IP is the most widely used networking protocol; it supports the idea of unique addresses for each computer on the network. IP is a connectionless, best-effort protocol; TCP reassembles the data after transmission. IP specifies the format and addressing scheme for each packet. Internet Protocol version 6. IPv6 is the next-generation IP protocol. The specification was completed in 1997 by IETF. IPv6 is backwardcompatible with and is designed to fix the shortcomings of IPv4, such as data security and maximum number of user addresses. IPv6 increases the address space from 32 to 128 bits, providing for an unlimited (for all intents and purposes) number of networks and systems; IPv6 is expected to slowly replace IPv4, with the two existing side by side for many years. IP address is a 32-bit number that identifies each unique sender or receiver of information that is sent in packets; it is written as four octets separated by periods (dotted-decimal format). An IP address has two parts: the identifier of a particular network and an identifier of the particular device (which can be a server or a workstation) within that network. You may add an optional subnetwork identifier. Only the network part of the address is looked at between the routers that move packets from one point to another along the network. Although you can have a static IP address, many IP addresses are assigned dynamically from a pool. Many corporate networks and online services economize on the number of IP addresses they use by sharing a pool of IP addresses among a large number of users. (The format of the IP address is slightly changed in IPv6.)

IGP

inline power

IP

IPv6

IP address

ExtremeWare XOS 11.3 Concepts Guide

654

I (Continued)
ISP An Internet Service Provider is an organization that provides access to the Internet. Small ISPs provide service via modem and ISDN while the larger ones also offer private line hookups (T1, fractional T1, etc.). Customers are generally billed a fixed rate per month, but other charges may apply. For a fee, a Web site can be created and maintained on the ISP's server, allowing the smaller organization to have a presence on the Web with its own domain name. Internal router. In OSPF, IR is an internal router that has all interfaces within the same area. Internet Router Discovery Protocol. Used with IP, IRDP enables a host to determine the address of a router that it can use as a default gateway. In Extreme Networks implementation, IP multinetting requires a few changes for the IRDP.

IR IRDP

J
jumbo frames These are Ethernet frames that are larger that 1522 bytes (including the 4 bytes in the CRC). The jumbo frame size is configurable on Extreme Networks devices; the range is from 1523 to 9216 bytes.

L
LACP Link Aggregation Control Protocol. LACP is part of the IEEE 802.3ad and automatically configures multiple aggregated links between switches. Link aggregation group. A LAG is the logical high-bandwidth link that results from grouping multiple network links in link aggregation (or load sharing). You can configure static LAGs or dynamic LAGs (using the LACP). Layer 2 is the second, or data link, layer of the OSI model, or the MAC layer. This layer is responsible for transmitting frames across the physical link by reading the hardware, or MAC, source and destination addresses. Layer 3 is the third layer of the OSI model. Also known as the network layer, Layer 3 is responsible for routing packets to different LANs by reading the network address. Light-emitting diode. LEDs are on the device and provide information on various states of the devices operation. See the Consolidated XOS Hardware Installation Guide for a complete explanation of the LEDs on devices running ExtremeWare XOS. ExtremeWare XOS version 11.1 introduces a licensing feature to the ExtremeWare XOS software. You must have a license, which you obtain from Extreme Networks, to apply the full functionality of some features.

LAG

Layer 2

Layer 3

LED

license

ExtremeWare XOS 11.3 Concepts Guide

655

Glossary

L (Continued)
link aggregation Link aggregation, also known as trunking or load sharing, conforms to IEEE 802.3ad. This feature is the grouping of multiple network links into one logical high-bandwidth link. In OSPF, there are four link types that you can configure: auto, broadcast, point-to-point, and passive. Link Layer Discovery Protocol. LLDP conforms to IEEE 802.1ab and is a neighbor discovery protocol. Each LLDP-enabled device transmits information to its neighbors, including chassis and port identification, system name and description, VLAN names, and other selected networking information. The protocol also specifies timing intervals in order to ensure current information is being transmitted and received. Load sharing, also known as trunking or link aggregation, conforms to IEEE 802.3ad. This feature is the grouping of multiple network links into one logical high-bandwidth link. For example, by grouping four 100 Mbps of full-duplex bandwidth into one logical link, you can create up to 800 Mbps of bandwidth. Thus, you increase bandwidth and availability by using a group of ports to carry traffic in parallel between switches. Link Fault Signal. LFS, which conforms to IEEE standard 802.3ae-2002, monitors 10 Gbps ports and indicates either remote faults or local faults. In ELRP, loop detection is the process used to detect a loop in the network. The switch sending the DLRP PDU waits to receive its original PDU back. If the switch received this original PDU, there is a loop in the network. Link state advertisement. An LSA is a broadcast packet used by link state protocols, such as OSPF. The LSA contains information about neighbors and path costs and is used by the receiving router to maintain a routing table. Link state database. In OSPF, LSDB is a database of information about the link state of the network. Two neighboring routers consider themselves to be adjacent only if their LSDBs are synchronized. All routing information is exchanged only between adjacent routers.

link type LLDP

load sharing

LFS

loop detection

LSA

LSDB

M
MAC address Media access control address. The MAC address, sometimes known as the hardware address, is the unique physical address of each network interface card on each device. Metropolitan area network. A MAN is a data network designed for a town or city. MANs may be operated by one organization such as a corporation with several offices in one city, or be shared resources used by several organizations with several locations in the same city. MANs are usually characterized by very high-speed connections.

MAN

ExtremeWare XOS 11.3 Concepts Guide

656

M (Continued)
master node In EAPS, the master node is a switch, or node, that is designated the master in an EAPS domain ring. The master node blocks the secondary port for all non-control traffic belonging to this EAPS domain, thereby avoiding a loop in the ring. In VRRP, the master router is the physical device (router) in the VRRP virtual router that is responsible for forwarding packets sent to the VRRP virtual router and for responding to ARP requests. The master router sends out periodic advertisements that let backup routers on the network know that it is alive. If the VRRP IP address owner is identified, it always becomes the master router. In ESRP, the master VLAN is the VLAN on the ESRP domain that exchanges ESRP-PDUs and data between a pair of ESRP-enabled devices. You must configure one master VLAN for each ESRP domain, and a master VLAN can belong to only one ESRP domain. Multiple exit discriminator. BGP uses the MED metric to select a particular border router in another AS when multiple border routers exist. In QoS, metering monitors the traffic pattern of each flow against the traffic profile. For out-of-profile traffic the metering function interacts with other components to either re-mark or drop the traffic for that flow. In the Extreme Networks implementation, you use ACLs to enforce metering. In ESRP, you configure zero or more member VLANs for each ESRP domain. A member VLAN can belong to only one ESRP domain. The state of the ESRP device determines whether the member VLAN is in forwarding or blocking state. Management Information Base. MIBs make up a database of information (for example, traffic statistics and port settings) that the switch makes available to network management systems. MIB names identify objects that can be managed in a network and contain information about the objects. MIBs provide a means to configure a network device and obtain network statistics gathered by the device. Standard, minimal MIBs have been defined, and vendors often have private enterprise MIBs. Port mirroring configures the switch to copy all traffic associated with one or more ports to a designated monitor port. The monitor port can be connected to an network analyzer or RMON probe for packet analyzer. Multimode fiber. MMF is a fiber optic cable with a diameter larger than the optical wavelength, in which more than one bound mode can propagate. Capable of sending multiple transmissions simultaneously, MMF is commonly used for communications of 2 kilometers or less.

master router

master VLAN

MED

metering

member VLAN

MIB

mirroring

MMF

ExtremeWare XOS 11.3 Concepts Guide

657

Glossary

M (Continued)
MSM Master Switch Fabric Module. This Extreme Networks-proprietary name refers to the module that holds both the control plane and the switch fabric for switches that run the ExtremeWare XOS software on modular switches. One MSM is required for switch operation; adding an additional MSM increases reliability and throughput. Each MSM has two CPUs. The MSM has LEDs as well as a console port, management port, modem port, and compact flash; it may have data ports as well. The MSM is responsible for upper-layer protocol processing and system management functions. When you save the switch configuration, it is saved to all MSMs. Maximum transmission unit. This term is a configurable parameter that determines the largest packet than can be transmitted by an IP interface (without the packet needing to be broken down into smaller units). Note: Packets that are larger than the configured MTU size are dropped at the ingress port. Or, if configured to do so, the system can fragment the IPv4 packets and reassemble them at the receiving end. multicast Multicast messages are transmitted to selected devices that specifically join the multicast group; the addresses are specified in the destination address field. In other words, multicast (point-to-multipoint) is a communication pattern in which a source host sends a message to a group of destination hosts. IP multinetting assigns multiple logical IP interfaces on the same circuit or physical interface. This allows one bridge domain (VLAN) to have multiple IP networks.

MTU

multinetting

N
NAT Network Address Translation. This is a network capability that enables a group of computers to dynamically share a single incoming IP address. NAT takes the single incoming IP address and creates a new IP address for each client computer on the network. Network login provides extra security to the network by assigning addresses only to those users who are properly authenticated. You can use web-based, MAC-based, or IEEE 802.1x-based authentication with network login. The two modes of operation are campus mode and ISP mode. A netmask is a string of 0s and 1s that mask, or screen out, the network part of an IP address, so that only the host computer part of the address remains. In ESRP, the neutral state is the initial state entered by the switch. In a neutral state, the switch waits for ESRP to initialize and run. A neutral switch does not participate in ESRP elections.

netlogin

netmask

neutral state/switch

ExtremeWare XOS 11.3 Concepts Guide

658

N (Continued)
NLRI Network layer reachability information. In BGP, the system sends routing update messages containing NLRI to describe a route and how to get there. A BGP update message carries one or more NLRI prefixes and the attributes of a route for each NLRI prefix; the route attributes include a BGP next hop gateway address, community values, and other information. In the Extreme Networks implementation, a node is a CPU that runs the management application on the switch. Each MSM on modular switches installed in the chassis is a node. In general networking terms, a node is a device on the network. Node Manager The Node Manager performs the process of node election, which selects the master, or primary, MSM when you have two MSMS installed in the modular chassis. The Node Manager is useful for system redundancy. Not-so-stubby area. In OSPF, NSSA is a stub area, which is connected to only one other area, with additional capabilities:

node

NSSA

External routes originating from an ASBR connected to the NSSA can be advertised within the NSSA. External routes originating from the NSSA can be propagated to other areas.

O
odometer In the Extreme Networks implementation, each field replaceable component contains a system odometer counter in EEPROM. On modular switches, using the CLI, you can display how long each following individual component has been in service:

chassis MSMs I/O modules power controllers

On stand-alone switches, you display the days of service for the switch. option 82 This is a security feature that you configure as part of BOOTP/DHCP. Option 82 allows a server to bind the clients port, IP address, and MAC number for subscriber identification. Open Systems Interconnection. OSI is the international standard computer network architecture known for its 7-layer reference model.

OSI

ExtremeWare XOS 11.3 Concepts Guide

659

Glossary

O (Continued)
OSI reference model The 7-layer standard model for network architecture is the basis for defining network protocol standards and the way that data passes through the network. Each layer specifies particular network functions; the highest layer is closest to the user, and the lowest layer is closest to the media carrying the information. So, in a given message between users, there will be a flow of data through each layer at one end down through the layers in that computer and, at the other end, when the message arrives, another flow of data up through the layers in the receiving computer and ultimately to the end user or program. This model is used worldwide for teaching and implementing networking protocols. Open Shortest Path First. This is an IGP. OSPF, a routing protocol for TCP/IP networks, uses a link state routing algorithm that calculates routes for packets based on a number of factors, including least hops, speed of transmission lines, and congestion delays. You can also configure certain cost metrics for the algorithm. This protocol is more efficient and scalable than vector-distance routing protocols. OSPF features include least-cost routing, ECMP routing, and load balancing. Although OSPF requires CPU power and memory space, it results in smaller, less frequent router table updates throughout the network. This protocol is more efficient and scalable than vector-distance routing protocols. OSPFv3 is one of the routing protocols used with IPV6 and is similar to OSPF.

OSPF

OSPFv3

P
packet This is the unit of data sent across a network. Packet is a generic term used to describe units of data at all levels of the protocol stack, but it is most correctly used to describe application data units. The packet is a group of bits, including data and control signals, arranged in a specific format. It usually includes a header, with source and destination data, and user data. The specific structure of the packet depends on the protocol used. In EAPS, the partner node is that end of the common link that is not a controller node; the partner node does not participate in any form of blocking. Powered device. In PoE, the PD is the powered device that plugs into the PoE switch. Protocol data unit. A PDU is a message of a given protocol comprising payload and protocol-specific control information, typically contained in a header. Protocol-Independent Multicast - Dense mode. PIM-DM is a multicast protocol that uses Reverse Path Forwarding but does not require any particular unicast protocol. It is used when recipients are in a concentrated area.

partner node

PD PDU

PIM-DM

ExtremeWare XOS 11.3 Concepts Guide

660

P (Continued)
PIM-SM Protocol-Independent Multicast - Sparse mode. PIM-SM is a multicast protocol that defines a rendezvous point common to both sender and receiver. Sender and receiver initiate communication at the rendezvous point, and the flow begins over an optimized path. It is used when recipients are in a sparse area. Packet Internet Groper. Ping is the ICMP echo message and its reply that tests network reachability of a device. Ping sends an echo packet to the specified host, waits for a response, and reports success or failure and statistics about its operation. PIM multicast border router. A PIMBR integrates PIM-DM and PIMSM traffic. Power over Ethernet. The PoE standard (IEEE 802.3af) defines how power can be provided to network devices over existing Ethernet connections. You use policy files in ExtremeWare XOS to specify ACLs and policies. A policy file is a text file (with a .pol extension) that specifies a number of conditions to test and actions to take. For ACLs, this information is applied to incoming traffic at the hardware level. Policies are more general and can be applied to incoming routing information; they can be used to rewrite and modify routing advertisements. Port mirroring configures the switch to copy all traffic associated with one or more ports to a designated monitor port. A packet bound for or heading away from the mirrored port is forwarded onto the monitor port as well. The monitor port can be connected to a network analyzer or RMON probe for packet analysis. Port mirroring is a method of monitoring network traffic that a network administrator uses as a diagnostic tool or debugging feature; it can be managed locally or remotely. Power On Self Test. On Extreme Networks switches, the POST runs upon powering-up the device. If the MGMT LED is yellow after the POST completes, contact your supplier for advice. In EAPS, a primary port is a port on the master node that is designated the primary port to the ring. In STP, protected VLANs are the other (other than the carrier VLAN) VLANs that are members of the STPD but do not define the scope of the STPD. Protected VLANs do not transmit or receive STP BPDUs, but they are affected by STP state changes and inherit the state of the carrier VLAN. Also known as non-carrier VLANs, they carry the data traffic. In EAPS, a protected VLAN is a VLAN that carries data traffic through an EAPS domain. You must configure one or more protected VLANs for each EAPS domain. This is also known as a data VLAN.

ping

PMBR PoE

policy files

port mirroring

POST

primary port protected VLAN

ExtremeWare XOS 11.3 Concepts Guide

661

Glossary

P (Continued)
proxy ARP This is the technique in which one machine, usually a router, answers ARP requests intended for another machine. By masquerading its identity (as an endstation), the router accepts responsibility for routing packets to the real destination. Proxy ARP allows a site to use a single IP address with two physical networks. Subnetting is normally a better solution. Per VLAN Spanning Tree +. This implementation of STP has a 1:1 relationship with VLANs. The Extreme Networks implementation of PVST+ allows you to interoperate with third-party devices running this version of STP. PVST is a earlier version of this protocol and is compatible with PVST+.

PVST+

Q
QoS Quality of Service. Policy-enabled QoS is a network service that provides the ability to prioritize different types of traffic and to manage bandwidth over a network. QoS uses various methods to prioritize traffic, including IEEE 802.1p values and IP DiffServ values.

R
RADIUS Remote Authentication Dial In User Service. RADIUS is a client/ server protocol and software that enables remote access servers to communicate with a central server to authenticate dial-in users and authorize their access to the requested system or service. RADIUS allows a company to maintain user profiles in a central database that all remote servers can share. It provides better security, allowing a company to set up a policy that can be applied at a single administered network point. With RADIUS, you can track usage for billing and for keeping network statistics. Reverse ARP. Using this protocol, a physical device requests to learn its IP address from a gateway server's ARP table. When a new device is set up, its RARP client program requests its IP address from the RARP server on the router. Assuming that an entry has been set up in the router table, the RARP server will return the IP address to the machine which can store it for future use. Request for Comment. The IETF RFCs describe the definitions and parameters for networking. Routing Information Protocol. This IGP vector-distance routing protocol is part of the TCP/IP suite and maintains tables of all known destinations and the number of hops required to reach each. Using RIP, routers periodically exchange entire routing tables. RIP is suitable for use only as an IGP. RIP next generation. RIPng is one of the routing protocols used with IPV6 and is similar to RIP.

RARP

RFC RIP

RIPng

ExtremeWare XOS 11.3 Concepts Guide

662

R (Continued)
RMON Remote monitoring. RMON is a standardized method to make switch and router information available to remote monitoring applications. It is an SNMP network management protocol that allows network information to be gathered remotely. RMON collects statistics and enables a management station to monitor network devices from a central location. It provides multivendor interoperability between monitoring devices and management stations. RMON is described in several RFCs (among them IETF RFC 1757 and RFC 2201). Network administrators use RMON to monitor, analyze, and troubleshoot the network. A software agent can gather the information for presentation to the network administrator with a graphical user interface (GUI). The administrator can find out how much bandwidth each user is using and what Web sites are being accessed; you can also set alarms to be informed of potential network problems. In STP, the root bridge is the bridge with the best bridge identifier selected to be the root bridge. The network has only one root bridge. The root bridge is the only bridge in the network that does not have a root port. In STP, the root port provides the shortest path to the root bridge. All bridges except the root bridge contain one root port. In BGP, you can combine the characteristics of several routes so they are advertised as a single route, which reduces the size of the routing tables. A route is flapping when it is repeatedly available, then unavailable, then available, then unavailable. In the ExtremeWare XOS BGP implementation, you can minimize the route flapping using the route flap dampening feature. In BGP, you can configure the routers within an AS such that a single router serves as a central routing point for the entire AS. In BGP, you can configure a fully meshed AS into several sub-ASs and group these sub-ASs into a routing confederation. Routing confederations help with the scalability of BGP. Rapid Spanning Tree Protocol. RSTP, described in IEEE 802.1w, is an enhanced version of STP that provides faster convergence. The Extreme Networks implementation of RSTP allows seamless interoperability with legacy STP.

root bridge

root port route aggregation

route flapping

route reflector routing confederation

RSTP

S
SA SCP Source address. The SA is the IP or MAC address of the device issuing the packet. Secure Copy Protocol. SCP2, part of SSH2, is used to transfer configuration and policy files.

ExtremeWare XOS 11.3 Concepts Guide

663

Glossary

S (Continued)
secondary port In EAPS, the secondary port is a port on the master node that is designated the secondary port to the ring. The transit node ignores the secondary port distinction as long as the node is configured as a transit node. sFlow allows you to monitor network traffic by statistically sampling the network packets and periodically gathering the statistics. The sFlow monitoring system consists of an sFlow agent (embedded in a switch, router, or stand-alone probe) and an external central data collector, or sFlow analyzer. Small form-factor pluggable. SFP is a specific type of GBIC, designed for use with small form factor connectors. These transceivers offer high speed and physical compactness. The 6in4 tunnels, which encapsulate IPv6 packets into IPv4 packets, use dynamic routing protocols to establish connectivity between several IPv6 networks through over the intervening IPv4 network. The 6in4 tunnel must be created at each tunnel endpoint. The IPv6 routing protocol considers the 6in4 tunnel as a single IPv6 hop, even if the tunnel comprises many IPv4 hops; the IPv6 protocol considers the 6in4 tunnel as a normal IPv6 point-to-point link. You can have many 6in4 tunnels per VR. The 6to4 tunnels are one way to send IPv6 packets over IPv4 networks. This transition mechanism provides a way to connect IPv6 end-site networks by automatically tunnelling over the intervening IPv4 Internet. A special IPv6 routing prefix is used to indicate that the remaining part of the external routing prefix contains the IPv4 endpoint address of a boundary IPv6 router for that site that will process IPv6-in-IPv4-encapsulated packets. You can have only one 6to4 tunnel per VR. Single-mode fiber. SMF is a laser-driven optical fiber with a core diameter small enough to limit transmission to a single bound mode. SMF is commonly used in long distance transmission of more than 3 miles; it sends one transmission at a time. Simple Network Management Protocol. SNMP is a standard that uses a common software agent to remotely monitor and set network configuration and runtime parameters. SNMP operates in a multivendor environment, and the agent uses MIBs, which define what information is available from any manageable network device. You can also set traps using SNMP, which send notifications of network events to the system log. Simple Network Time Protocol. SNTP is used to synchronize the system clocks throughout the network. An extension of the Network Time Protocol, SNTP can usually operate with a single server and allows for IPv6 addressing.

sFlow

SFP

6in4 tunnels

6to4 tunnels

SMF

SNMP

SNTP

ExtremeWare XOS 11.3 Concepts Guide

664

S (Continued)
SSH Secure Shell, sometimes known as Secure Socket Shell, is a UNIXbased command interface and protocol of securely gaining access to a remote computer. With SSH commands, both ends of the client/server connection are authenticated using a digital certificate, and passwords are protected by being encrypted. At Extreme Networks, the SSH is a separate software module, which must be downloaded separately. (SSH is bundled with SSL in the software module.) Secure Sockets Layer. SSL is a protocol for transmitting private documents using the Internet. SSL works by using a public key to encrypt data that is transferred over the SSL connection. SSL uses the public-and-private key encryption system, which includes the use of a digital certificate. At Extreme Networks, SSL is bundled with the SSH software module, which must be downloaded separately. SSL used for other applications than SSH, CNA at Extreme Networks for example. Use ESRP standard mode if your network contains switches running ExtremeWare and switches running ExtremeWare XOS, both participating in ESRP. Spanning Tree Protocol. STP is a protocol, defined in IEEE 802.1d, used to eliminate redundant data paths and to increase network efficiency. STP allows a network to have a topology that contains physical loops; it operates in bridges and switches. STP opens certain paths to create a tree topology, thereby preventing packets from looping endlessly on the network. To establish path redundancy, STP creates a tree that spans all of the switches in an extended network, forcing redundant paths into a standby, or blocked, state. STP allows only one active path at a time between any two network devices (this prevents the loops) but establishes the redundant links as a backup if the initial link should fail. If STP costs change, or if one network segment in the STP becomes unreachable, the spanning tree algorithm reconfigures the STP topology and re-establishes the link by activating the standby path. Spanning Tree Domain. An STPD is an STP instance that contains one or more VLANs. The switch can run multiple STPDs, and each STPD has its own root bridge and active path. In the Extreme Networks implementation of STPD, each domain has a carrier VLAN (for carrying STP information) and one or more protected VLANs (for carrying the data). The mode of operation for the STPD. The two modes of operation are:

SSL

standard mode

STP

STPD

STPD mode

802.1dCompatible with legacy STP and other devices using the IEEE 802.1d standard. 802.1wCompatible with Rapid Spanning Tree (RSTP).

stub areas

In OSPF, a stub area is connected to only one other area (which can be the backbone area). External route information is not distributed to stub areas.

ExtremeWare XOS 11.3 Concepts Guide

665

Glossary

S (Continued)
superloop In EAPS, a superloop occurs if the common link betwee two EAPS domains goes down and the master nodes of both domains enter the falied state putting their respective secondary ports into the forwarding state. If there is a data VLAN spanning both EAPS domains, this action forms a loop between the EAPS domains. The primary responsibility of the system health checker is to monitor and poll error registers. In addition, the system health checker can be enabled to periodically send diagnostic packets. System health check errors are reported to the syslog.

system health check

T
TACACS+ Terminal Access Controller Access Control System. Often run on UNIX systems, the TACAS+ protocol provides access control for routers, network access servers, and other networked computing devices via one or more centralized servers. TACACS+ provides separate authentication, authorization, and accounting services. User passwords are administered in a central database rather than in individual routers, providing easily scalable network security solutions. You identify packets as belonging to the same tagged VLAN by putting a value into the 12-bit (4 octet) VLAN ID field that is part of the IEEE 802.1Q field of the header. Using this 12-bit field, you can configure up to 4096 individual VLAN addresses (usually some are reserved for system VLANs such as management and default VLANs); these tagged VLANs can exist across multiple devices. The tagged VLAN can be associated with both tagged and untagged ports. Topology change notification. The TCN is a timer used in RSTP that signals a change in the topology of the network. Transmission Control Protocol. Together with Internet Protocol (IP), TCP is one of the core protocols underlying the Internet. The two protocols are usually referred to as a group, by the term TCP/IP. TCP provides a reliable connection, which means that each end of the session is guaranteed to receive all of the data transmitted by the other end of the connection, in the same order that it was originally transmitted without receiving duplicates. Trivial File Transfer Protocol. TFTP is an Internet utility used to transfer files, which does not provide security or directory listing. It relies on UDP. In EAPS, the transit node is a switch, or node, that is not designated a master in the EAPS domain ring.

tagged VLAN

TCN TCP

TFTP

transit node

U
UDP User Datagram Protocol. This is an efficient but unreliable, connectionless protocol that is layered over IP (as is TCP). Application programs must supplement the protocol to provide error processing and retransmitting data. UDP is an OSI Layer 4 protocol.

ExtremeWare XOS 11.3 Concepts Guide

666

U
unicast untagged VLAN A unicast packet is communication between a single sender and a single receiver over a network. A VLAN remains untagged unless you specifically configure the IEEE 802.1Q value on the packet. A port cannot belong to more than one untagged VLAN using the same protocol. User-based security model. In SNMPv3, USM uses the traditional SNMP concept of user names to associate with security levels to support secure network management.

USM

V
virtual link In OSPF, when a new area is introduced that does not have a direct physical attachment to the backbone, a virtual link is used. Virtual links are also used to repair a discontiguous backbone area. In the Extreme Networks implementations, virtual routers allow a single physical switch to be split into multiple virtual routers. Each virtual router has its own IP address and maintains a separate logical forwarding table. Each virtual router also serves as a configuration domain. The identity of the virtual router you are working in currently displays in the prompt line of the CLI. The virtual routers discussed in relation to Extreme Networks switches themselves are not the same as the virtual router in VRRP. In VRRP, the virtual router is identified by a virtual router (VRID) and an IP address. A router running VRRP can participate in one or more virtual routers. The VRRP virtual router spans more than one physical router, which allows multiple routers to provide redundant services to users. virtual router MAC address In VRRP, RFC 2338 assigns a static MAC address for the first five octets of the VRRP virtual router. These octets are set to 00-00-5E-0001. When you configure the VRRP VRID, the last octet of the MAC address is dynamically assigned the VRID number. Virtual LAN. The term VLAN is used to refer to a collection of devices that communicate as if they are on the same physical LAN. Any set of ports (including all ports on the switch) is considered a VLAN. LAN segments are not restricted by the hardware that physically connects them. The segments are defined by flexible user groups you create with the CLI. Variable-length subnet masks. In OSPF, VLSMs provide subnets of different sizes within a single IP block. Virtual MAN. In ExtremeWare XOS software, VMANs are a bidirectional virtual data connection that creates a private path through the public network. One VMAN is completely isolated from other VMANs; the encapsulation allows the VMAN traffic to be switched over Layer 2 infrastructure. You implement VMAN using an additional 892.1Q tag and a configurable EtherType; this feature is also known as Q-in-Q switching.

virtual router

VLAN

VLSM VMAN

ExtremeWare XOS 11.3 Concepts Guide

667

Glossary

V (Continued)
VoIP Voice over Internet Protocol is an Internet telephony technique. With VoIP, a voice transmission is cut into multiple packets, takes the most efficient path along the Internet, and is reassembled when it reaches the destination. This virtual router is part of the embedded system in Extreme Networks BlackDiamond 10K switches. The VR-Control is used for internal communications between all the modules and subsystems in the switch. It has no ports, and you cannot assign any ports to it. It also cannot be associated with VLANs or routing protocols. (Referred to as VR-1 in earlier ExtremeWare XOS software versions.) This virtual router is part of the embedded system in Extreme Networks BlackDiamond 10K switches. The VR-Default is the default virtual router on the system. All data ports in the switch are assigned to this virtual router by default; you can add and delete ports from this virtual router. Likewise, this virtual router contains the default VLAN. Although you cannot delete the default VLAN from this virtual router, you can add and delete any user-created VLANs. One instance of each routing protocol is spawned for this virtual router, and they cannot be deleted. (Referred to as VR-2 in earlier ExtremeWare XOS software versions.) In VRRP, the VRID identifies the VRRP virtual router. Each VRRP virtual router is given a unique VRID. All the VRRP routers that participate in the VRRP virtual router are assigned the same VRID. This virtual router is part of the embedded system in Extreme Networks BlackDiamond 10K switches. The VR-Mgmt enables remove management stations to access the switch through Telnet, SSH, or SNMP sessions; and it owns the management port. The management port cannot be deleted from this virtual router, and no other ports can be added.The Mgmt VLAN is created is in this virtual router, and it cannot be deleted; you cannot add or delete any other VLANs or any routing protocols to this virtual router. (Referred to as VR-0 in earlier ExtremeWare XOS software versions.) Virtual Router Redundancy Protocol. VRRP specifies an election protocol that dynamically assigns responsibility for a virtual router to one of the VRRP routers on a LAN. The VRRP router controlling the IP address(es) associated with a virtual router is called the master router, and forwards packets sent to these IP addresses. The election process provides dynamic failover in the forwarding responsibility should the master router become unavailable. In case the master router fails, the virtual IP address is mapped to a backup router's IP address; this backup becomes the master router. This allows any of the virtual router IP addresses on the LAN to be used as the default firsthop router by end-hosts. The advantage gained from using VRRP is a higher availability default path without requiring configuration of dynamic routing or router discovery protocols on every host. VRRP is defined in RFC 2338. Any router that is running VRRP. A VRRP router can participate in one or more virtual routers with VRRP; a VRRP router can be a backup router for one or more master routers.

VR-Control

VR-Default

VRID

VR-Mgmt

VRRP

VRRP router

ExtremeWare XOS 11.3 Concepts Guide

668

X
XENPAK Pluggable optics that contain a 10 Gigabit Ethernet module. The XENPAKs conform to the IEEE 802.3ae standard.

ExtremeWare XOS 11.3 Concepts Guide

669

Glossary

ExtremeWare XOS 11.3 Concepts Guide

670

Index of Commands
C
check policy, 258 clear access-list counter, 273 clear counters, 208, 329 clear inline-power stats ports, 173 clear log counters, 208 clear log static, 613 clear session, 44, 69 clear slot, 110, 613 clear vlan dhcp-address-allocation, 319 configure access-list, 259, 272 configure account, 44 configure banner, 44 configure bgp add aggregate-address, 574 configure bgp add network, 578 configure bgp delete network, 578 configure bgp import-policy, 260, 284 configure bgp neighbor dampening, 576 configure bgp neighbor no-dampening, 576 configure bgp neighbor peer-group, 575 configure bgp neighbor route-policy, 260, 284 configure bgp peer-group dampening, 576 configure bgp peer-group no dampening, 576 configure bgp peer-group route-policy, 260, 284 configure bootprelay add, 509 configure bootprelay delete, 509 configure cli max-sessions, 60 configure core-dumps, 627 configure diffserv examination code-point, 301 configure diffserv replacement, 302 configure dns-client add, 54 configure dns-client default-domain, 54 configure dos-protect acl-expire, 321 configure dos-protect interval, 321 configure dos-protect trusted-ports, 321 configure dos-protect type l3-protect alertthreshold, 321 configure dos-protect type l3-protect notifythreshold, 321 configure dot1p type, 298 configure eaps add control vlan, 406 configure eaps add protect vlan, 407 configure eaps failtime, 405 configure eaps failtime expiry-action, 405 configure eaps fast-convergence, 407 configure eaps hellotime, 405 configure eaps mode, 404 configure eaps primary port, 406 configure eaps secondary port, 406 configure eaps shared-port domain, 414 configure eaps shared-port mode, 414 configure eaps shared-port segment-timeout, 415 configure edp advertisement-interval, 135 configure elrp-client one-shot, 622 configure elrp-client periodic, 622 configure esrp add master, 468 configure esrp add member, 469 configure esrp add track-environment failover, 470 configure esrp add track-iproute, 471 configure esrp add track-ping, 471 configure esrp add track-vlan, 470 configure esrp delete elrp-poll ports, 478 configure esrp delete master, 468, 620 configure esrp delete member, 469 configure esrp delete track-iproute, 471 configure esrp delete track-ping, 471 configure esrp delete track-vlan, 470 configure esrp domain-id, 460, 468 configure esrp election-policy, 465, 470 configure esrp elrp-master-poll disable, 478 configure esrp elrp-premaster-poll disable, 478 configure esrp elrp-premaster-poll enable, 477 configure esrp mode, 459 configure esrp port-mode ports, 475 configure esrp ports mode, 474 configure esrp ports no-restart, 473 configure esrp ports restart, 473 configure esrp timer premaster, 464 configure failsafe-account, 49 configure fdb agingtime, 252 configure firmware, 607 configure igmp snooping add static group, 582 configure igmp snooping add static router, 582, 588 configure igmp snooping delete static group, 582, 588 configure igmp snooping delete static router, 582, 588 configure igmp snooping filter, 582 configure inline-power budget slot, 165, 170 configure inline-power disconnect-precedence, 166, 171 configure inline-power label ports, 173 configure inline-power operator-limit ports, 168,

ExtremeWare XOS 11.3 Concepts Guide

671

Index of Commands 173 configure inline-power priority ports, 166, 171 configure inline-power usage-threshold, 167, 172 configure iparp add proxy, 499 configure ip-mtu vlan, 117, 118 configure iproute add default, 61, 66, 500, 522 configure iproute priority, 498, 521 configure jumbo-frame size, 117 configure log filter, 202, 205 configure log filter events match, 206 configure log target, 200 configure log target filter, 200 configure log target format, 206 configure log target match, 204 configure log target syslog, 199 configure mld snooping add static group, 588 configure netlogin add mac-list, 369 configure netlogin base-url, 364 configure netlogin delete mac-list, 370 configure netlogin dot1x guest-vlan, 362 configure netlogin dotix timers, 363 configure netlogin local-user, 357, 358 configure netlogin move-fail-action, 350 configure netlogin port mode, 372 configure netlogin redirect-page, 364 configure node slot priority, 71 configure ospf area external-filter, 260, 284 configure ospf area interarea-filter, 260, 284 configure ospf area nssa, 547 configure ospf area stub, 547, 559 configure ospf area timer, 552 configure ospf ase-limit, 544 configure ospf timer, 552 configure ospf virtual-link timer, 552 configure ospf vlan area, 547, 558 configure ospf vlan timer, 551, 552, 563 configure pim add vlan, 583 configure ports auto off, 44, 113, 617 configure ports auto on, 113 configure ports auto-polarity off, 115 configure ports auto-polarity on, 115 configure ports limit-learning, 316 configure ports lock-learning, 317 configure ports preferred-medium, 140 configure ports qosprofile, 304 configure ports redundant, 137 configure ports unlock-learning, 318 configure powersupply, 81 configure protocol add, 227 configure qosprofile ingress, 312 configure radius server client-ip, 323 configure radius shared-secret, 323, 324 configure radius timeout, 323 configure radius-accounting, 324, 333 configure radius-accounting timeout, 324 configure rip import-policy, 260, 284 configure rip trusted-gateway, 260, 284 configure rip vlan route-policy, 260, 284 configure sflow agent, 211 configure sflow collector, 211 configure sflow max-cpu-sample-limit, 212 configure sflow poll-interval, 212 configure sflow ports sample-rate, 212 configure sflow sample-rate, 212 configure sharing add ports, 124 configure sharing address-based, 121 configure sharing delete ports, 124 configure slot module, 44, 110, 613 configure snmp add community, 84 configure snmp add trapreceiver community, 84 configure snmp delete trapreceiver, 84 configure snmpv3 add access, 87 configure snmpv3 add filter subtree type, 91 configure snmpv3 add filter-profile param, 91 configure snmpv3 add group user, 88 configure snmpv3 add mib-view, 89 configure snmpv3 add mib-view subtree, 89 configure snmpv3 add notify tag, 92 configure snmpv3 add target-addr param ipaddress, 90 configure snmpv3 add target-params, 86 configure snmpv3 add user, 87 configure snmpv3 delete access, 88 configure snmpv3 delete filter, 91 configure snmpv3 delete filter-profile, 92 configure snmpv3 delete group user, 88 configure snmpv3 delete mib-view, 90 configure snmpv3 delete notify, 92 configure snmpv3 delete target-addr, 90 configure snmpv3 delete target-params, 91 configure snmpv3 delete user, 87 configure snmpv3 engine-boots, 87 configure snmpv3 engine-id, 87 configure snmpv3 target-params user mp-model, 91 configure sntp-client, 94 configure sntp-client update-interval, 94 configure ssh2 key, 45, 336 configure ssh2 key pregenerated, 336 configure ssl certificate, 341 configure ssl certificate pregenerated, 342 configure ssl privkeyword pregenerated, 342 configure stpd add vlan, 427, 447 configure stpd default-encapsulation, 426 configure stpd delete vlan, 428 configure stpd mode, 425 configure stpd ports link-type, 438 configure stpd ports mode, 426

672

ExtremeWare XOS 11.3 Concepts Guide

Index of Commands configure stpd tag, 447 configure sys-health-check interval, 191, 631 configure sys-recovery-level, 45, 193 configure sys-recovery-level slot, 194 configure tacacs server client-ip, 331 configure tacacs shared-secret, 331, 333 configure tacacs timeout, 331 configure tacacs-accounting timeout, 333 configure telnet access-profile, 68 configure telnet port, 67 configure telnet vr, 67 configure time, 45 configure timezone, 45, 93 configure vlan add esrp elrp-poll ports, 478 configure vlan add ports, 427 configure vlan dhcp-address-range, 319 configure vlan dhcp-lease-timer, 319 configure vlan dhcp-options, 319 configure vlan esrp elrp-master-poll enable, 478 configure vlan ipaddress, 45, 65, 500, 522 configure vlan name, 228 configure vlan qosprofile, 304 configure vr add ports, 244 configure vr add protocol, 245 configure vr delete ports, 244 configure vr delete protocol, 245 configure vrrp vlan vrid add track-iproute, 486 configure vrrp vlan vrid add track-ping, 486 configure vrrp vlan vrid add track-vlan, 486 configure vrrp vlan vrid delete track-iproute, 486 configure vrrp vlan vrid delete track-ping, 486 configure vrrp vlan vrid delete track-vlan, 486 cp, 99, 102, 628 create account, 45, 49 create bgp neighbor peer-group, 575 create bgp peer-group, 574 create eaps, 404 create eaps shared-port, 414 create esrp, 458, 467 create log filter, 202 create netlogin local-user, 356, 357 create ospf area, 547, 558 create protocol, 226 create stpd, 424, 447 create virtual-router, 244 create vlan, 45, 246 delete fdbentry, 316 delete netlogin local-user, 359 delete stpd, 424 delete virtual router, 244 delete vlan, 45 disable access-list refresh blackhole, 259 disable bgp export, 578 disable bgp neighbor remove-private-as-numbers, 577 disable bootp vlan, 45, 64 disable clear-flow, 376 disable cli-config-logging, 45, 209 disable clipaging, 45 disable cpu-monitoring, 106 disable dhcp ports vlan, 318 disable dhcp vlan, 64 disable dos-protect, 321 disable eaps, 407, 408 disable edp ports, 134 disable elrp-client, 622 disable esrp, 465, 468, 469, 620 disable idletimeout, 45 disable inline-power, 164, 169 disable inline-power legacy, 168, 172 disable inline-power ports, 169 disable inline-power slot, 169 disable ipforwarding, 329 disable learning port, 253 disable log debug-mode, 626 disable log target, 198 disable netlogin, 350 disable netlogin dot1x guest-vlan ports, 363 disable netlogin logout-privilege, 365 disable netlogin ports vlan, 350 disable netlogin session-refresh, 365 disable ospf capability opaque-lsa, 545 disable ospf export, 551, 562 disable ospf export static, 497, 520 disable port, 45, 113 disable radius, 324 disable radius-accounting, 325 disable rip export, 534 disable rip export static, 497, 520 disable ripng export, 542 disable rmon, 216 disable sflow, 211 disable sflow ports, 211 disable sharing, 123 disable smartredundancy, 137 disable snmp access, 83 disable ssh2, 45 disable sys-health-check slot, 191, 630 disable tacacs, 332 disable tacacs-accounting, 334

D
delete delete delete delete delete account, 45, 49 bgp peer-group, 574 eaps, 404 eaps shared-port, 414, 415 esrp, 467

ExtremeWare XOS 11.3 Concepts Guide

673

Index of Commands disable telnet, 45, 68 disable udp-echo-server, 513 disable web https, 341 download bootrom, 53, 606 download image, 53, 593, 599 download ssl certificate, 341 download ssl privkey, 342 enable ospf export static, 497, 520 enable pim, 583 enable port, 113 enable radius, 324 enable radius-accounting, 325, 334 enable rip, 500, 522 enable rip export, 534 enable rip export static, 497, 520 enable ripng export, 541 enable rmon, 216 enable sflow, 211 enable sflow ports, 211 enable sharing grouping, 123 enable smartredundancy, 137 enable snmp access, 83 enable sntp-client, 94 enable ssh2, 46, 336, 338 enable stpd, 447 enable stpd auto-bind, 428 enable stpd rapid-root-failover, 429 enable sys-health-check slot, 190, 630 enable tacacs, 332 enable telnet, 46, 68 enable udp-echo-server, 513 enable web https, 340

E
edit policy, 67, 258, 337 eject memorycard, 627 enable access-list refresh blackhole, 259 enable bgp aggregation, 574 enable bgp export, 578 enable bgp neighbor remove-private-as-numbers, 577 enable bootp vlan, 45, 64 enable bootprelay, 509 enable clear-flow, 376 enable cli-config-logging, 45, 209 enable clipaging, 46 enable cpu-monitoring, 106 enable dhcp ports vlan, 318 enable dhcp vlan, 64 enable diffserv replacement ports, 301 enable dos-protect, 321 enable dos-protect simulated, 320 enable dot1p replacement ports, 299 enable eaps, 407 enable edp ports, 134 enable elrp-client, 621 enable esrp, 469 enable idletimeout, 46 enable inline-power, 164, 169 enable inline-power legacy, 168, 172 enable inline-power ports, 169 enable inline-power slot, 169 enable ipforwarding, 500, 522 enable ipmcforwarding, 583 enable jumbo-frame ports, 117 enable license, 46 enable log debug-mode, 209, 626 enable log target, 198 enable log target console, 207 enable log target session, 207 enable netlogin, 350 enable netlogin dot1x guest-vlan ports, 362 enable netlogin logout-privilege, 365 enable netlogin ports, 350 enable netlogin session-refresh, 365 enable ospf, 500, 522 enable ospf capability opaque-lsa, 545 enable ospf export, 551, 562

H
history, 44, 46

I
install firmware, 607 install image, 594, 599, 600

L
link aggregation

troubleshooting, 119 logout, 66 ls, 70, 100, 101, 102, 628 ls memorycard, 101

M
mv, 98, 102, 628

N
nslookup, 54

P
ping, 48, 53, 54, 55

674

ExtremeWare XOS 11.3 Concepts Guide

Index of Commands

Q
quit, 66

R
reboot, 72, 73, 596, 597 refresh policy, 259 reset inline-power ports, 167, 173 restart process, 104 rm, 101, 102, 629 RMON configuring, 216 output, 217 run diagnostics, 185 run elrp, 622 run msm-failover, 71, 73, 599 run update, 594

S
save configuration, 601, 604 save debug tracefiles memorycard, 627 scp2, 339 show access-list, 259, 273 show access-list counter, 273 show account, 49 show accounts, 49 show banner, 46 show bgp peer-group, 577 show bootprelay, 510 show checkpoint-data, 72, 73 show clear-flow, 376 show clear-flow acl-modified, 376 show clear-flow any, 376 show clear-flow port, 376 show clear-flow rule-all, 376 show clear-flow rule-triggered, 376 show clear-flow vlan, 376 show configuration, 102, 115, 602 show cpu-monitoring, 107 show dhcp-client state, 64 show dhcp-server, 319 show diagnostics slot, 189 show diffserv, 302 show dos-protect, 321 show eaps, 408 show eaps shared-port, 413, 415 show edp, 134 show elrp, 478, 622 show esrp, 459, 471, 476, 479 show esrp counters, 476 show fans, 197, 613 show fdb, 252

show igmp snooping filter, 583 show igmp snooping static group, 582 show inline-power, 169, 171, 172, 174 show inline-power configuration ports, 171, 173, 177 show inline-power info ports, 167, 178 show inline-power slot, 170, 176 show inline-power stats ports, 179 show inline-power stats slot, 176 show iparp, 501 show ipconfig, 501, 522 show iproute, 501, 522 show iproute ipv6, 522 show log, 207 show log components, 201 show log configuration filter, 203 show log configuration target, 199 show log counters, 208 show log events, 201 show management, 68, 84, 217, 329, 336 show memory process, 105 show mirroring, 133 show mld snooping static group, 588 show neighbor-discovery cache, 522 show netlogin local-users, 359 show netlogin mac-list, 370 show netlogin vlan, 350 show node, 73 show odometers, 631 show ospf, 551, 555, 563 show ospf area, 555 show ospf interfaces, 555 show ospf lsdb, 555 show ospf lsdb area lstype, 555 show ports configuration, 613 show ports info detail, 316 show ports information, 305, 312 show ports qosmonitor, 308, 312 show ports rxerrors, 183, 617 show ports sharing, 127 show ports statistics, 182 show ports txerrors, 182 show power, 82, 196, 613 show power budget, 82 show power controller, 82 show process, 103 show protocol, 232 show qosprofile, 308 show qosprofile ports, 312 show rmon memory, 217 show session, 69 show sflow, 211, 213 show sflow statistics, 213 show slot, 83, 110, 195

ExtremeWare XOS 11.3 Concepts Guide

675

Index of Commands show snmpv3 access, 88 show snmpv3 filter, 91 show snmpv3 filter-profile, 91 show snmpv3 group, 88 show snmpv3 mib-view, 89 show snmpv3 notify, 92 show snmpv3 target-addr, 90 show snmpv3 target-params, 91 show snmpv3 user, 87 show sntp-client, 94 show ssl, 341, 343 show stpd, 429, 452 show stpd ports, 438, 452 show switch, 71, 73, 93, 94, 193, 329, 592, 593, 598 show temperature, 195 show version, 592 show virtual-router, 245 show vlan, 231, 368, 618 show vlan dhcp-address-allocation, 319 show vlan dhcp-config, 319 show vlan security, 316 show vlan stpd, 453 show vman, 238 show vrrp, 486 ssh2, 339 start process, 105 synchronize, 71, 73, 604 unconfigure sflow, 213 unconfigure sflow agent, 211 unconfigure sflow collector, 211 unconfigure stpd ports link-type, 438 unconfigure switch, 46, 602 unconfigure vlan dhcp, 319 unconfigure vlan dhcp-address-range, 319 unconfigure vlan dhcp-options, 319 uninstall image, 594 upload log, 208 use configuration, 602 use image, 593

V
virtual-router, 246

T
telnet, 53, 64 terminate process, 104 tftp, 67, 69, 102, 258, 337, 603 top, 629 traceroute, 53, 54, 55

U
unconfigure unconfigure unconfigure unconfigure unconfigure unconfigure unconfigure unconfigure 166, 171 unconfigure 168, 173 unconfigure unconfigure 172 unconfigure access-list, 259, 272 eaps primary port, 408 eaps secondary port, 408 eaps shared-port link-id, 415 eaps shared-port mode, 415 elrp-client, 622 inline-power budget slot, 165, 170 inline-power disconnect-precedence, inline-power operator-limit ports, inline-power priority ports, 166, 171 inline-power usage-threshold, 167, port redundant, 137

676

ExtremeWare XOS 11.3 Concepts Guide

Index
Symbols
# prompt, 48 * prompt, 48 .cfg file, 601 .pol file, 257 .xmod file, 594 .xos file, 594 > prompt, 48 counters, 273 description, 261 editing, 258 examples, 273274 file syntax, 262 metering, 271 refreshing, 259 rule entry, 262 rules, 270 transferring to the switch, 258 troubleshooting, 257 action modifiers, ACL, 264 action statements, policy, 283 actions, ACL, 263 active interface, 580 Address Resolution Protocol. See ARP address-based load-sharing, 120, 121 admin account, 48 advertisement interval, EDP, 135 agent, local, 210 agent, RMON, 213 aging entries, FDB, 250 alarm actions, 216 Alarms, RMON, 215 area 0, OSPF, 547 area 0, OSPFv3, 558 areas, OSPF, 546 areas, OSPFv3, 558 ARP and IP multinetting, 504 communicating with devices outside subnet, 500 configuring proxy ARP, 499 displaying system table, 501 incapable device, 499 proxy ARP between subnets, 500 proxy ARP, description of, 499 responding to ARP requests, 499 AS numbers, private, 577 authentication local database, 355 RADIUS, 322, 351 TACACS+, 330 authentication methods 802.1x, 359 MAC-based, 368 web-based, 363

Numerics
10 gigabit ports, 114 802.1D, 425, 426 802.1Q tagging, 223, 224 802.1w, 425 802.1x authentication advantages, 347 co-existence with web-based, 346 configuration, example, 361 disadvantages, 347 interoperability requirements, 359 methods, 359 requirements, 346 VLAN movement, post-authentication, 363

A
access levels, 47 accessing the switch, 46 account types admin, 48 user, 48 accounting server RADIUS, 324 TACACS, 333 accounts creating, 49 default, 48 deleting, 49 failsafe, 49 viewing, 49 ACL match conditions, 265 ACL-based traffic, QoS, 296 ACLs .pol file, 257 action modifiers, 264 actions, 263

ExtremeWare XOS 11.3 Concepts Guide

677

Index AuthnoPriv, 88 AuthPriv, 88 autobind ports, 428 automatic failover, 138139 autonegotiation description, 113 displaying setting, 140, 141 flow control, 113 off, 114 on, 113 support, 115 autonomous system expressions, 281 autonomous system, description, 568 autopolarity, 115 route reflectors, 569 route selection, 577 static networks, 578 bi-directional rate shaping configuring, 312 description, 310 maximum bandwidth settings, 311 maximum committed rate, 311 maximum ingress queues, 310 minimum bandwidth settings, 311 BlackDiamond 10K series switches, 22 BlackDiamond 8800 family of switches, 22 BlackDiamond 8806 MSM slots, 111 BlackDiamond 8810 MSM slot, 110 blackhole entries, FDB, 315 blackhole entry, FDB, 251 Bootloader accessing, 605 exiting, 606 prompt, 605 BOOTP relay configuring, 509 viewing, 510 BOOTP server, 64 BOOTP, using, 64 BootRom prompt, 605 BootROM, upgrading, 606 Bootstrap Protocol. See BOOTP Border Gateway Protocol. See BGP bulk checkpointing, 72

B
backbone area, OSPF, 547 backbone area, OSPFv3, 558 backplane diagnostics configuring, 191 disabling, 191 enabling, 190 base URL, network login, 364 becomes, 139 BGP and IP multinetting, 506 attributes, 568 autonomous system, 568 autonomous system path, 568 cluster, 569 community, 568 description, 568 examples route confederations, 571574 route reflector, 569571 features, 569 loopback interface, 574 peer groups creating, 574 deleting, 574 description, 574 mandatory parameters, 574 neighbors, 575 private AS numbers, 577 redistributing to OSPF, 577 route aggregation description, 574 using, 574 route confederations, 571 route flap dampening configuring, 576 description, 575 viewing, 576

C
cabling 10/10/1000BASE-T ports, 115 crossover cables, 115 cabling for redundancy, 139, 140 campus mode, 348 carrier vlan, STP, 424 checkpointing bulk, 72 dynamic, 73 statistics, displaying, 73 CLEAR-Flow configuring, 375 enabling and disabling, 376 overview, 375 rule types, 378 CLI # prompt, 48 * prompt, 48

678

ExtremeWare XOS 11.3 Concepts Guide

Index > prompt, 48 access levels, 47 command shortcuts, 41 configuration access, 48 history, 44 limits, 42 line-editing keys, 43 named components, 41 prompt line, 48 starting up, 51 symbols, 41 syntax, 39 syntax helper, 40 syntax symbols (table), 42, 168 users adding, 49 deleting, 49 viewing, 49 using, 3940 cluster, 569 collector, remote, 211 combination ports, 138, 139 combo ports, 138 command history, 44 prompts, 48 shortcuts, 41 Command Line Interface. See CLI command syntax, understanding, 39 common commands (table), 4446 communicating with devices outside subnet, 500 community strings private, 84 public, 84 read, 84 read-write, 84 components, EMS, 201 conditions, EMS, 201 configuration primary and secondary, 601 returning to factory default, 602 viewing current, 602 configuration command prompt, 48 configuration domain, virtual routers, 243 configuration file .cfg file, 601 copying, 99, 628 deleting, 101, 629 description, 601 displaying, 100, 628 downloading, 603 managing, 98 overview, 102 relaying from primary to backup, 72 renaming, 98, 628 saving changes, 601 selecting, 602 uploading, 603 using, 602 configuration mode, XML, 102 configuration, change log, 209 configuring PoE, 169 connectivity, 54 console connection, 60 console, maximum sessions, 59 control VLAN, EAPS, 406 controlling Telnet access, 66 conventions, guide notice icons, 22 text, 23 core image. See image Core license, 33 CPU monitoring description, 106 disabling, 106 enabling, 106 overview, 98 troubleshooting, 106 CPU utilization, TOP command, 629

D
database applications, and QoS, 291 database overflow, OSPF, 544 debug mode, 209, 626 See also EMS default accounts, 48 gateway, 485, 495 passwords, 50 port status, 113 returning to factory settings, 602 software values, 36 users, 48 denial of service protection configuring, 321 description, 320 disabling, 321 enabling, 321 destination VLAN, network login, 357 DHCP network login and, 346 requirement for web-based network login, 346 DHCP relay and IP multinetting, 507 configuring, 509 viewing, 510

ExtremeWare XOS 11.3 Concepts Guide

679

Index DHCP server and IP multinetting, 507 description, 318 diagnostics displaying, 182, 189 I/O module, 185 LEDs, 186 MSM, 185 running, 185 Summit X450 switch, 185 DiffServ See also QoS and virtual routers, 300 code point, 301 configuring, 300 examining, 301 disabling route advertising, RIP, 533 disabling route advertising, RIPng, 541 distance-vector protocol, description, 531, 539 DNS configuring, 54 description, 53 Domain Name Service. See DNS domains, EAPS, 397 domains, ESRP, 460 domains, STP, 423 duplex setting, ports, 113 duplex, displaying setting, 140, 141 dynamic checkpointing, 73 dynamic entries, FDB, 250, 315 Dynamic Host Configuration Protocol. See DHCP dynamic routes, 497 dynamic routes, IPv6, 520 health-check packet, 399, 405 hellotime, 405 licensing, 395 link down message, 398 master node, 396, 404 multiple domains per switch, 400 names, 41 overview, 29 polling, 398 polling timers, configuring, 405 primary port, 396, 406 process, 398 protected VLAN, 407 ring port, unconfiguring, 408 ring restoration, 399 rings and a common link, 402 secondary port, 396, 397, 406 shared port common link failure, 412 configuration rules, 418 configuring the domain ID, 414 creating and deleting, 414 defining the mode, 414 description, 411 show eaps display fields (table), 409, 416 show eaps shared-port display fields (table), 416 spatial reuse, 401 status information, displaying, 408, 415 switch mode, defining, 404 transit node, 396, 404 troubleshooting, 397 EDP advertisement interval, 135 clearing counters, 134 default, 134 description, 133 disabling, 134 enabling, 134 timeout interval, 135 viewing information, 134, 141 egress flooding displaying, 256 guidelines, 255 egress traffic rate limiting, 309 election algorithms, ESRP, 465 ELRP and ESRP, 477 description, 476 loop detection, 620 master behavior (ESRP), 477 pre-master behavior (ESRP), 477 standalone, 620 with ESRP, overview, 456

E
EAPOL and DHCP, 346 EAPS and IP multinetting, 507 common link, 411 configuring, 403 control VLAN, 406 description, 395, 397 EAPS domain creating and deleting, 404 enabling and disabling, 407 enabling, 403 enabling and disabling on a switch, 407 failed state, 398, 405 failtime expiry action, 399, 405 failtimer, 399, 405 Fast Convergence, 397, 407 FDB, 398 hardware layer, 398

680

ExtremeWare XOS 11.3 Concepts Guide

Index without ESRP, 620 EMISTP description, 426 example, 433 rules, 434 EMS and dual MSM systems, 198 configuring targets components, 201 conditions, 201 description, 199 severity, 200 subcomponents, 201 debug mode, 209 description, 197 displaying messages console, 207 session, 207 event message formats, 206 expressions matching, 204 regular, 204 filtering event messages, 199 filters configuring, 202 creating, 202 viewing, 203 log target default, 198 disabling, 198 enabling, 198 types, 198 logs displaying, 207 displaying counters, 208 uploading, 208 parameters behavior, 206 matching, 204 viewing components and subcomponents, 201 viewing conditions, 201 encapsulation modes, 425 See also STP entries, FDB, 249 EPICenter support, 61 ESRP 802.1Q tag, 461 and ELRP, 456 and IP multinetting, 484, 507 and load sharing, 474 and OSPF, 464 and STP, 484 and VRRP, 484, 489, 494 auto toggle, 456, 460 basic topology, 457 description, 455 direct link, 461 displaying data, 476 domain ID, 461 domains, description, 460 dont count, 474 election algorithms, 465 environment tracking, 470 ESRP-aware, 458 examples, 479483 extended mode description, 456, 459 differences between standard mode, 459 failover time, 464 groups, 475 hitless failover support, 461 host attach, 473 linking switches, 461 load sharing and, 474 master behavior, 463 definition, 456 determining, 462 electing, 463 election algorithms, 465 multiple VLANs sharing a host port, 461 neutral state, behavior, 463 overview, 30 ping tracking, 471 port restart, 473 port weight, 459 pre-master behavior, 463 timeout, 464 reasons to use, 456 restarting ports, 473 route table tracking, 470 slave mode behavior, 463 definition, 456 standard mode description, 456, 459 differences between extended mode, 459 tracking description, 469 example, 472 troubleshooting, 457, 458, 619 VLANid, 461 ESRP-aware, description, 458 Ether type, 238 Ethernet Automatic Protection Switching. See EAPS Event Management System. See EMS

ExtremeWare XOS 11.3 Concepts Guide

681

Index Events, RMON, 215 explicit packet marking, QoS, 296 extended mode, ESRP domain, 456, 459 Extreme Discovery Protocol. See EDP Extreme Loop Recovery Protocol. See ELRP Extreme Multiple Instance Spanning. See EMISTP Extreme Standby Router Protocol. See ESRP filters, protocol, 226 flooding, 254 flooding, displaying, 141 flow control displaying setting, 140, 141 Gigabit Ethernet ports, 113 Forwarding Database. See FDB

F
factory default values, 36 failover, 71 failsafe account, 49 Fast Convergence, EAPS, 397 fault protection, 396 FDB configuring aging time, 252 contents, 249 creating a permanent entry example, 251 description, 249 disabling MAC learning, 253 displaying, 252 dynamic entries, limiting, 316 egress flooding, 254 entries adding, 250 aging, 250 blackhole, 251 description, 249 dynamic, 250 limiting, 253 multicast with multiport entries, 256 non-aging, 251 permanent, 251 prioritizing, 253 static, 251 prioritizing entries, 315 feature highlights, 27 feature pack, 29 features, platform-specific, 22 file server applications, and QoS, 291 file syntax ACL, 262 policy, 279 file system administration, 97 filename requirements, 98, 628 filenames, troubleshooting, 98, 628 files copying, 99, 628 deleting, 101, 629 displaying, 100, 628 renaming, 98, 628 filter profiles and filters, SNMPv3, 91

G
graceful OSPF restart, 545 Greenwich Mean Time Offsets (table), 95 groups ESRP, 475 SNMPv3, 87 guest VLAN description, 361 disabling, 363 enabling, 362 troubleshooting, 361

H
hardware support, 27 helper-mode, 545 History, RMON, 214 hitless failover BlackDiamond 8800 caveats, 78 description, 74 ESRP, 461 I/O ports on MSM, 111 modular switch caveats, 78 network login, 348 platform support, 77 PoE PoE

hitless failover support, 163


protocol support, 74 STP, 429 host attach, ESRP, 473

I
I/O module diagnostics, 185 MSM, same module on BlackDiamond 8800 MSM I/O ports, same module on BlackDiamond 8800 MSM, 110 power management, 79 I/O ports BlackDiamond 8806 switch, 111 BlackDiamond 8810 switch, 110 IEEE 80.2.1w, 436

682

ExtremeWare XOS 11.3 Concepts Guide

Index IEEE 802.1D, 423 IEEE 802.1Q, 223 IEEE 802.1Q tagging, 223 IEEE 802.1x, comparison with web-based authentication, 346 IGMP and IP multinetting, 506 description, 581 snooping, 581, 587 snooping filters, 582 static, 582 image .xos file, 594 definition, 591 downloading, 593 primary and secondary, 593 rescue, 623 selecting a partition, 593 upgrading, 593 version string, 592 ingress rate shaping. See bi-directional rate shaping or QoS ingress rates, 310 Input/Output module. See I/O module interface active, 580 passive, 580 interface, IP multinetting, 503 interfaces, IPv6 router, 516 interfaces, router, 496 Internet Group Management Protocol. See IGMP Internet Router Discovery Protocol. See IRDP interoperability requirements, 802.1x authentication, 359 IP address VLANs, 229 VMANs, 232 IP address, entering, 65 IP fragmentation, 118 IP multicast routing configuring, 583 description, 579 example, 583 IGMP description, 581 snooping, 581, 587 snooping filters, 582 PIM mode interoperation, 581 PIM multicast border router (PMBR), 581 PIM-DM, 580 PIM-SM, 580 IP multinetting and ESRP, 484 configuring, 508 description, 503 example, 509 interface, 503 interoperability with ARP, 504 BGP, 506 DHCP relay, 507 DHCP server, 507 EAPS, 507 ESRP, 507 IGMP, IGMP snooping, 506 IRDP, 505 OSPF, 505 PIM, 506 RIP, 506 STP, 507 VRRP, 507 overview, 31 recommendations, 503 topology, 503 IP parameters, configuring, 64 IP unicast routing BOOTP relay, 509 configuration examples, 501 configuring, 500 default gateway, 495 DHCP relay, 509 enabling, 500 multinetting description, 503 example, 509 proxy ARP, 499 relative priorities, 498 router interfaces, 496 routing table dynamic routes, 497 multiple routes, 497 populating, 496 static routes, 497, 520 verifying the configuration, 501 IPv6 displaying VLANs, 231 link aggregation, 120 ping, 55 VLANs, 219, 230 IPv6 addresses, scoped, 517 IPv6 multicast routing MLD description, 587 IPv6 unicast routing configuration examples, 522 configuring, 522 enabling, 522 relative priorities, 521

ExtremeWare XOS 11.3 Concepts Guide

683

Index router interfaces, 516 routing table dynamic routes, 520 routing table IPv6 multiple routes, 520 populating, 519 verifying the configuration, 522 IRDP, and IP multinetting, 505 ISP mode, 348 SSH2, 36 verifying, 35 limit, sFlow maximum CPU sample limit, 212 limiting entries, FDB, 253 line-editing keys, 43 link aggregation See also load sharing adding or deleting ports, 124 and control protocols, 119 and IPv6, 120 and software-controlled redundant ports, 120 and VMANs, 119 description, 119 displaying, 126 dynamic example, 126 LACP active and standby ports, 122 algorithms, 125 configuring, 124 displaying, 126 LAG, 123 master port, 123 maximum links, 125 verifying configuration, 125 maximum ports and groups, 124 restrictions, 124 static troubleshooting, 119 Link Fault Signal. See LFS Link Layer Discovery Protocol (LLDP), 147 link types, configuring in RSTP, 438 link-state advertisement. See LSA link-state database. See LSDB link-state protocol, description, 531, 539 LLDP, 147 and 802.1x, 150 configuring, 156 default TLVs, 151 EMS messages, 150 enabling, 156 EtherType, 148 length limit, 148 mandatory TLVs, 152 multicast address, 148 port configuration information, 160, 162 repeated TLVs, 151 restoring defaults, 160 SNMP traps, 150 standards-mandated TLVs, 151 statistics, 161 system description TLV, 153 timers, 150

J
jumbo frames BlackDiamond and Summit X450, 116 configuring on the BlackDiamond 8800 switch, 116 description, 116 enabling, 116 IP fragmentation, 118 path MTU discovery, 117 troubleshooting, 116 viewing port settings, 141 VMANs, 116

K
keys line-editing, 43 port monitoring, 183

L
LACP See link aggregation LAG See link aggregation latestReceivedEngineTime, 86 Layer 1, troubleshooting, 609 Layer 2, troubleshooting, 610 Layer, troubleshooting, 610 LEDs, during diagnostics, 186 legacy powered devices. See PoE LFS description, 114 troubleshooting, 114 license voucher, 35 licensing description, 33 enabling, 35 license voucher, 35 ordering, 35 security license, 35 software keys, 33

684

ExtremeWare XOS 11.3 Concepts Guide

Index troubleshooting, 149 unconfiguring, 156, 160 LLDPDU, 148 load sharing See also link aggregation algorithms, 120, 121 and ESRP dont count, 474 and ESRP host attach, 474 and VLANs, 126 BlackDiamond 10K switch, 121 BlackDiamond 8800 switch, 121 configuring, 123 displaying, 141 master port, 123 maximum ports and groups, 124 Summit X450 switch, 121 troubleshooting, 126 local agent, 210 local database authentication description, 355 password, 355 user name, 355 local netlogin account creating, 356 deleting, 359 destination VLAN creating, 357 modifying, 358 displaying, 359 modifying, 358 log target, EMS disabling, 198 enabling, 198 logging configuration changes, 209 logging in, 51 logging messages. See EMS logout privilege, network login, 365 loop detection, using ELRP and ESRP, 477 loop detection, using standalone ELRP, 620 loop tests, using ELRP and ESRP, 477 loop tests, using standalone ELRP, 620 loopback interface, 574 LSA type numbers (table) OSPF, 544 OSPFv3, 557 LSA, description, 544, 557 LSDB, description, 544, 557 configuration, secure MAC, 370 description, 368 disabling, 369 disadvantages, 347 enabling, 369 MAC-based security, 253, 315 MAC-based VLANs, network login, 372 management access, 47 management accounts displaying, 52 Management Information Base. See MIBs management port, 61 Management Switch Fabric Module. See MSM manually bind ports, 427 master port, load sharing, 123 match conditions, ACL, 265 match conditions, policy, 280 matching expressions, EMS, 204 matching parameters, EMS, 204 maximum CPU sample limit, sFlow, 212 memory protection, 98, 105 metering, 271, 310 mgmt VLAN, 61 MIBs, supported, 84, 643 MLD description, 587 static, 588 modular switch jumbo frames, 116 load sharing, configuring, 123 monitor port, 130 port number, 43, 112 port-mirroring, 130, 131 slot configuration, 109 virtual port, 131 module recovery actions, 194 configuring, 194 description, 193 displaying, 195 troubleshooting, 195 module, type and number of, 110 monitor port, port-mirroring, 130 monitoring command prompt, 48 monitoring the switch, 181 MSM console sessions, 59 diagnostics, 185 reboot, 597 MSM module BlackDiamond 8806 switch, 111 BlackDiamond 8810 switch, 110 MSM prompt, troubleshooting, 616 MSMs, synchronizing, 604

M
MAC learning, FDB, 253 MAC-based authentication advantages, 347 configuration, example, 371

ExtremeWare XOS 11.3 Concepts Guide

685

Index multicast FDB static entry, 256 VMANs, 234 multinetting. See IP multinetting multiple routes, 497 multiple routes IPv6, 520 multiple supplicants, network login support, 347 session refresh, 365 settings, displaying, 350 user netlogin-only disabled, 351 netlogin-only enabled, 351 user accounts, 351 web-based authentication, user login, 367 noAuthnoPriv, 88 node election configuring priority, 71 determining primary, 70 overview, 70 node states, 73 node status, viewing, 73 non-aging entries, FDB, 251 normal area, OSPF, 548 normal area, OSPFv3, 559 notification tags, SNMPv3, 92 notification, SNMPv3, 90 Not-So-Stubby-Area. See NSSA NSSA, 547, 559 See also OSPF See also OSPFv3

N
names character types, 41 conventions, 41 maximum length of, 41 VLAN, 228 VLAN, STP, EAPS, 41 native VLAN, PVST+, 436 netlogin. See network login netlogin-only disabled, 351 netlogin-only enabled, 351 network login authenticating users, 351 authentication methods, 346 campus mode, 348 configuration examples 802.1x, 361 MAC-based, 371 web-based, 365 description, 345 disabling, 350 disabling, port, 350 enabling, 350 exclusions and limitations, 351 guest VLAN, 361 hitless failover support, 348 ISP mode, 348 local account creating, 356 deleting, 359 displaying, 359 modifying, 358 local account, destination VLAN creating, 357 modifying, 358 local database authentication, 355 logout privilege, 365 MAC-based VLANs, 372 move fail action, 350 multiple supplicants, 347 port, enabling, 350 RADIUS attributes, 352 RADIUS authentication, 351 redirect page, 364 secure MAC, 369

O
opaque LSAs, OSPF, 545 Open Shortest Path First IPv6. See OSPFv3 Open Shortest Path First. See OSPF OSPF advantages, 532 and ESRP, 464 and IP multinetting, 505 area 0, 547 areas, 546 authentication, 551 backbone area, 547 configuration example, 553554 consistency, 544 database overflow, 544 description, 531, 543 display filtering, 555 enabling, 500 graceful restart, 545 link type, 549 LSA, 544 LSDB, 544 normal area, 548 NSSA, 547 opaque LSAs, 545 point-to-point links, 549 redistributing routes configuring, 534, 550 description, 533, 550

686

ExtremeWare XOS 11.3 Concepts Guide

Index enabling or disabling, 550 redistributing to BGP, 577 restart, 545 router types, 546 settings, displaying, 555 stub area, 547 timers, 551 virtual link, 548 wait interval, configuring, 551 OSPFv3 advantages, 540 area 0, 558 areas, 558 authentication, 563 backbone area, 558 configuration example, 563565 description, 539, 557 enabling, 522 link type, 560 LSA, 557 LSDB, 557 normal area, 559 NSSA, 559 redistributing routes configuring, 541, 562 description, 541, 561 enabling or disabling, 562 router types, 558 stub area, 559 timers, 563 virtual link, 559 Per VLAN Spanning Tree. See PVST+ permanent entries, FDB, 251 permit-established, 274 PIM and IP multinetting, 506 mode interoperation, 581 multicast border router (PMBR), 581 PIM-DM description, 580 example, 584 PIM-SM description, 580 example, 585 rendezvous point, 580 ping troubleshooting, 55 platform availability, 27 platform dependence, 22 PoE budgeted power, 165, 170 capacitance measurement, 172 configuration display, 173 configuring, 169 default power, 170 deny port, 170 denying power, 165 disconnect precedence, 170 EMS message, 167 enabling and disabling power, 169 features, 163 LEDs for usage, 168 legacy powered devices, 172 operator limit, 172 port fault state, 166 port labels, 173 port power limits, 168 port priority for PoE, 170 power budget, 173 power checking, 164 powering PoE modules, 164 required power, 164 reserving power per slot, 170 resetting ports, 173 SNMP events, 171 statistics, 173 troubleshooting, 165, 171 upper port power limit, 172 usage threshold, 171 PoE features, 163 poison reverse, RIP, 533 poison reverse, RIPng, 541 policies action statements, 283 autonomous system expressions, 281

P
partition, 593 passive interface, 580 password security configuring, 51 displaying, 52 passwords, 50 creating, 51 default, 50 displaying, 52 failsafe account, 49 forgetting, 51 local database authentication, 355 security, 50 shared secret, RADIUS, 323 shared secret, RADIUS accounting, 324 shared secret, TACACS, 331 shared secret, TACACS accounting, 333 troubleshooting, 50 path MTU discovery, 117 peer groups, 574

ExtremeWare XOS 11.3 Concepts Guide

687

Index examples translating a route map, 286 translating an access profile, 284 file syntax, 279 rule entry, 279 policy file copying, 99, 628 deleting, 101, 629 displaying, 100, 628 renaming, 98, 628 policy match conditions, 280 policy-based QoS. See QoS polling interval, sFlow, 212 port autonegotiation, 113 configuring, 111 duplex setting, 113 enabling and disabling, 113 flow control, 113 LFS, 114 link aggregation, 119 load sharing, 119 management, 61 monitoring display keys, 183 network login, 345 numbers and ranges, 42, 112 receive errors, 183 software-controlled redundant configuring, 137 description, 135 speed configuring, 113 displaying, 140, 141 supported types of, 113 transmit errors, 182 utilization, 140 viewing configuration, 140 information, 140 receive errors, 183 statistics, 182 transmit errors, 182 wildcard combinations, 43, 112 port lists, 42, 112 port mode, 448 port priority, STP, 448 port restart, ESRP, 473 port weight, ESRP, 459 port-based load-sharing, 120, 121 port-based VLANs, 220223 port-mirroring and protocol analyzers, 131 description, 130 displaying, 133 examples, 132 guidelines, 131 monitor port, 130 tagged and untagged frames, 131 traffic filter, 130, 131 troubleshooting, 131 virtual port, 131 post-authentication VLAN movement, network login, 363 power checking, PoE modules, 164 power management consumption, 79 displaying information, 82 initial system boot-up, 79 loss of power, 80 overriding, 81 re-enabling, 81 replacement power supply, 80 Summit X450, 81 Power over Ethernet. See PoE power supply controller, 79 powered devices. See PoE primary image, 593 prioritizing entries, FDB, 253 private AS numbers, 577 private community, SNMP, 84 privilege levels admin, 48 user, 48 privileges creating, 49 default, 48 viewing, 49 probe, RMON, 213 probeCapabilities, 215 probeDateTime, 215 probeHardwareRev, 215 probeResetControl, 215 probeSoftwareRev, 215 process control, 98 start, 103 stop, 103 terminate, 103 profiles, QoS, 293, 294 prompt admin account, 48 Bootloader, 605 BootRom, 605 unsaved changes, 48 user account, 48

688

ExtremeWare XOS 11.3 Concepts Guide

Index protected VLAN, EAPS, 407 protected VLAN, STP, 424 protocol analyzers, use with port-mirroring, 131 protocol filters, 226 Protocol Independent Multicast- Dense Mode. See PIM-DM Protocol Independent Multicast. See PIM Protocol Independent Multicast-Sparse Mode. See PIM-SM protocol-based VLANs, 225 proxy ARP communicating with devices outside subnet, 500 conditions, 499 configuring, 499 description, 499 MAC address in response, 499 responding to requests, 499 subnets, 500 public community, SNMP, 84 PVST+ description, 426, 436 native VLAN, 436 VLAN mapping, 436 default mapping to QoS profile, 301 examining, 301 replacing value, 301 viewing mapping to QoS profile, 302 examples source port, 304 VLAN, 304 file server applications, 291 guidelines, 309 ingress hardware queues default mapping to priority value, 310 description, 310 ingress QoS profile (IQP), 310 maximum bandwidth, 294 metering, 271, 310 minimum bandwidth, 294 monitoring real-time performance, 308 overview, 30 peak rates, 294 precedence of traffic, 295 priority, 294, 295 profiles default, 294, 295 description, 292 naming, 292 parameters, 293, 294 qostype priorities, 295 queues, 289 sFlow, 292 Summit X450 specific, 292 traffic groupings ACL-based, 296 description, 292, 295 explicit packet marking, 296 source port, 304 VLAN, 304 traffic guidelines, 291 traffic precedence, 295 troubleshooting, 292, 303 verifying, 308 video applications, 290 viewing port settings, 141, 304 voice applications, 290 web browsing applications, 291 weight, 293 Quality of Service. See QoS

Q
QoS 802.1p priority changing QoS profile mapping, 298 default mapping to QoS profile, 298 overview, 297 replacing value, 299 and ACLs, 292 and duplex, 291 applications, 290 bandwidth utilization, 289 bi-directional rate shaping configuring, 312 description, 310 maximum bandwidth, 311 maximum committed rate, 311 minimum bandwidth settings, 311 BlackDiamond 8800 specific, 292 buffer, 293 class of service, 296 classification priorities, 295 committed rates, 294 database applications, 291 default QoS profiles, 294, 295 description, 289 DiffServ changing mapping to QoS profile, 301 configuring, 300

R
RADIUS accounting configuring, 324 enabling and disabling, 325, 334 password, 324

ExtremeWare XOS 11.3 Concepts Guide

689

Index and TACACS+, 62, 322, 330 client configuration, 325 description, 62, 322 enabling and disabling, 323 Merit server configuration (example), 328 password, 323 per-command authentication, 325 per-command configuration (example), 329 RFC 2138 attributes, 326 server configuration, 323 servers, 322 TCP port, 325 user accounts, creating, 351 RADIUS accounts, network login, 351 RADIUS attributes, network login, 352 rapid root failover, 429 Rapid Spanning Tree Protocol. See RSTP rate limiting displaying, 141 egress traffic, 309 rate shaping, bi-directional. See bi-directional rate shaping read-only switch access, 84 read-write switch access, 84 reboot MSM, 597 switch, 596 receive errors, port, 183 redirect page, network login, 364 redirection, URL. See URL redirection redundant ports, software-controlled configuring, 137 description, 135 related publications, 23 relative route priorities IPv4, 498 IPv6, 521 Remote Authentication Dial In User Service. See RADIUS remote collector, 211 Remote Monitoring. See RMON renaming a VLAN, 228 rendezvous point, 580 rescue image, 623 resilience, 396 responding to ARP requests, 499 restart graceful, 545 returning to factory defaults, 602 RFCs, 641 BGP, 567 bridge, 448 IPv4 multicast routing, 579 IPv4 unicast routing, 495 IPv6 unicast routing, 515, 517, 518 OSPF, 543 RIP, 531 RIPng, 539 VRRP, 485 RIP advantages, 532 and IP multinetting, 506 configuration example, 535537 description, 531, 532 disabling route advertising, 533 enabling, 500 limitations, 532 poison reverse, 533 redistributing routes configuring, 534, 550 description, 533, 550 enabling or disabling, 534 redistributing to BGP, 577 routing table entries, 532 split horizon, 533 triggered updates, 533 version 2, 533 RIPng advantages, 540 configuration example, 542 description, 539 disabling route advertising, 541 enabling, 522 limitations, 540 poison reverse, 541 redistributing routes configuring, 541, 562 description, 541, 561 enabling or disabling, 541 routing table entries, 540 split horizon, 541 triggered updates, 541 RMON agent, 213 alarm actions, 216 Alarms group, 215 description, 213 Events group, 215 features supported, 214 History group, 214 management workstation, 214 probe, 213 probeCapabilities, 215 probeDateTime, 215 probeHardwareRev, 215 probeResetControl, 215 probeSoftwareRev, 215

690

ExtremeWare XOS 11.3 Concepts Guide

Index Statistics group, 214 trapDestTable, 216 route aggregation, 574 route confederations, 571 route flap dampening, 575 route reflectors, 569 route selection, 577 router interfaces, 496, 516 router types, OSPF, 546 router types, OSPFv3, 558 Routing Information Protocol, IPv6. See RIPng Routing Information Protocol. See RIP routing protocols and virtual routers, 245 routing table entries, RIP, 532 routing table entries, RIPng, 540 routing table IPv6, populating, 519 routing table, populating, 496 routing. See IP unicast routing routing. See IPv6 unicast routing RSTP See also STP and STP, 446 configuring, 447 designated port rapid behavior, 441 link types auto, 438 broadcast, 438 configuring, 438 description, 438 edge, 438 point-to-point, 438 operation, 439 overview, 436 port roles alternate, 437 backup, 437 designated, 437 edge, 437 root, 437 rapid reconvergence, 442 receiving bridge behavior, 442 root port rapid behavior, 440 timers, 438 topology information, propagating, 442 rule entry ACL, 262 policy, 279 rule types, 378 saving configuration changes, 601 scoped IPv6 addresses, 517 SCP2, 339 secondary image, 593 Secure Copy Program 2. See SCP2 protocol secure MAC configuration, example, 370 description, 369 Secure Shell 2. See SSH2 protocol Secure Socket Layer. See SSL security and safe defaults mode, 315 egress flooding, 254 security license, 35 security name, SNMPv3, 87 session refresh, network login, 365 sessions console, 59 deleting, 69 maximum number of, 59 shell, 60 SSH2, 69 Telnet, 63 TFTP, 69 severity levels, EMS, 199 sFlow BlackDiamond 8800 switches, 292 configuring, 210 displaying configuration, 213 displaying statistics, 213 enabling on specific ports, 211 on the switch, 211 local agent, 210 maximum CPU sample limit, 212 overview, 30, 209 polling interval, 212 remote collector, 211 resetting values, 213 sampling rate, 212 Summit X450 switch, 292 shared secret RADIUS, 323 RADIUS accounting, 324 TACACS, 331 TACACS accounting, 333 shell configuring, 60 maximum number of, 60 overview, 60 Simple Network Management Protocol. See SNMP Simple Network Time Protocol. See SNTP slot

S
safe defaults mode, 46 safe defaults script, 46 sampling rate, sFlow, 212

ExtremeWare XOS 11.3 Concepts Guide

691

Index automatic configuration, 109 clearing, 110 diagnostics, 184 displaying information, 110 manual configuration, 110 mismatch, 110 preconfiguring, 110 Smart Redundancy configuring, 137 description, 135 displaying, 141 port recovery, 136 SNAP protocol, 227 SNMP and safe defaults mode, 83 community strings, 84 configuring, 84 settings, displaying, 84 supported MIBs, 84 system contact, 84 system location, 84 system name, 84 trap receivers, 84 using, 82 SNMPEngineBoots, 86 snmpEngineID, 86 SNMPEngineTime, 86 SNMPv3 filter profiles and filters, 91 groups, 87 MIB access control, 89 notification, 90 overview, 85 security, 86 security name, 87 tags, notification, 92 target address, 90 target parameters, 90 user name, 87 SNTP configuring, 93 Daylight Savings Time, 93 description, 92 example, 96 Greenwich Mean Time offset, 93 Greenwich Mean Time Offsets (table), 95 NTP servers, 93 software version for platforms, 27 software factory defaults, 36 software functionality, 33 software image. See image software licensing, 33 software module .xmod file, 594 activating, 594 description, 594 downloading, 593 overview, 29, 591 uninstalling, 594 software signature, 592 software-controlled redundant ports and link aggregation, 120 description, 135 displaying, 141 displaying configuration, 137 troubleshooting, 135, 137 typical configurations, 135 spanning tree identifier. See StpdID Spanning Tree Protocol. See STP speed, displaying setting, 140, 141 speed, ports configuring, 113 displaying, 140, 141 split horizon, RIP, 533 split horizon, RIPng, 541 SSH2 client, 338 SSH2 license, 36 SSH2 protocol ACL policy, 337 authentication key, 336 default port, 336 description, 69, 335 enabling, 336 maximum number of sessions, 69 sample ACL policies, 337 TCP port number, 336 troubleshooting, 336 SSL certificates, downloading, 341 certificates, generating, 341 certificates, pre-generated, 342 description, 339 disabling, 341 enabling, 340 private key, downloading, 342 private key, pregenerated, 342 secure web access, 340 using commands, 340 stand-alone switch load sharing example, 125 port number, 43, 112 standard mode, ESRP domain, 456, 459 standards, 641 start process, 103 static IGMP, 582 static MLD, 588

692

ExtremeWare XOS 11.3 Concepts Guide

Index static networks, and BGP, 578 static routes, 497, 520 statistics, port, 182 Statistics, RMON, 214 status monitoring, 181 stop process, 103 STP advanced example, 433 and ESRP, 484 and IP multinetting, 507 and RSTP, 446 and VLANs, 424 and VRRP, 489 autobind ports, 428 basic configuration example, 430 bridge priority, 448 carrier vlan, 424 configurable parameters, 448 configuration examples, 448 configuring, 447 description, 423 displaying settings, 141, 452 domains 802.1D, 425 802.1w, 425 creating, 424 deleting, 424 description, 423 displaying, 452 EMISTP example, 433 rules, 434 encapsulation mode 802.1D, 426 description, 425 EMISTP, 426 PVST+, 426 forward delay, 448 guidelines, 447 hello time, 448 hitless failover support, 429 manually bind ports, 427 max age, 448 names, 41 path cost, 448 port and multiple STPDs, 423 port mode, 448 port priority, 448 port states blocking, 426 disabled, 427 displaying, 452 forwarding, 427 learning, 427 listening, 427 protected VLAN, 424 PVST+, description, 436 rapid root failover, 429 rules and restrictions, 447 StpdID, 426, 448 troubleshooting, 447, 618 StpdID, 426 strings, community, 84 stub area, OSPF, 547 stub area, OSPFv3, 559 subcomponents, EMS, 201 Subnetwork Access Protocol. See SNAP protocol Summit X450 switch, 22 supplicant side requirements, 359 switch basic information, 56 switch management console, 60 overview, 59 TFTP, 6970 user sessions, 59 switch RMON features, 214 switch, monitoring, 181 switch, reboot, 596 symbols, command syntax, 41 synchronizing MSMs, 604 syntax See also CLI abbreviated, 40 understanding, 39 syntax helper, 40 system contact, SNMP, 84 system diagnositcs, 184 system health check, 189 system health checker configuring backplane diagnostics, 191 description, BlackDiamond 10K switch, 189 description, BlackDiamond 8800 family, 190 disabling backplane diagnostics, 191, 630 enabling backplane diagnostics, 190, 630 example, BlackDiamond 10K switch, 191 example, BlackDiamond 8800 family, 192 modes of operation, BlackDiamond 10K switch, 189, 630 modes of operation, BlackDiamond 8800 family, 190 modes of operation, BlackDiamond 8800 family of switches, 630 system health, monitoring, 189 system LEDs, 612 system location, SNMP, 84 system name, SNMP, 84 system odometer, 631

ExtremeWare XOS 11.3 Concepts Guide

693

Index system recovery configuring, 193 description, 193 displaying, 193 system redundancy bulk checkpointing, 72 configuring node priority, 71 determining the primary node, 70 dynamic checkpointing, 73 failover, 71 node election, 70 relaying configurations, 72 viewing checkpoint statistics, 73 status, 73 system temperature, 195 system virtual routers, 242 session establishing, 63 maximum number of, 63 opening, 63 terminating, 68 viewing, 69 TCP port number, 64 using, 62 telnet MSM, 53 temperature range behavior, modular switch, 632 behavior, Summit X450 switch, 632 ExtremeWare XOS, 632 temperature, displaying fans, 197 I/O modules, 195 MSM modules, 195 power controllers, 195 power supplies, 196 Summit X450 switch, 196 Terminal Access Controller Access Control System Plus. See TACACS+ terminate process, 103 TFTP connecting to another host, 69 default port, 70 description, 69 maximum number of sessions, 69 server, 593 server requirements, 69, 629 using, 69, 603 TFTP server, troubleshooting, 69 timeout interval, EDP, 135 toggling, ESRP modes of operation, 456, 460 TOP command, 629 TOS, 300 traceroute, 55 traffic filter, port-mirroring, 130, 131 traffic groupings, and QoS, 295 transmit errors, port, 182 trap receivers, SNMP, 84 trapDestTable, 216 triggered updates, RIP, 533 triggered updates, RIPng, 541 Trivial File Transfer Protocol. See TFTP troubleshooting ACLs, 257 campus mode, 348 connectivity, 54 copying files, 99 CPU utilization, 106 debug mode, EMS, 626 deleting files, 101

T
TACACS accounting configuring, 333 password, 333 configuration example, 332 password, 331 server configuration, 331 TACACS accounting configuration example, 334 TACACS+ and RADIUS, 62, 322, 330 description, 62, 330 servers, specifying, 330 tagging, VLAN, 223 target address, SNMPv3, 90 target parameters, SNMPv3, 90 technical support, contacting, 634 Telnet ACL policy, 67 and safe defaults mode, 66 changing port, 67 client, 63 configuring virtual router, 67 connecting to another host, 64 controlling access, 66 default port, 64 default virtual router, 64 description, 62 disabling, 68 displaying status, 68 re-enabling, 68 sample ACL policies, 67 server, 63

694

ExtremeWare XOS 11.3 Concepts Guide

Index diagnostics viewing results, 189 disabling backplane diagnostics, 630 downloads and TFTP, 69, 629 EAPS, 397 enabling backplane diagnostics, 630 ESRP, 457, 458, 619 filenames, 98, 628 guest VLAN configuration, 361 hitless failover, BlackDiamond 8800, 78 hitless failover, modular switch, 78 IP, 32 IP fragmentation, 118 ISP mode, 348 jumbo frames, 116 Layer 1, 609 Layer 3, 610 Layer2, 610 LEDs BlackDiamond 10K switch I/O module diagnostics, 186 BlackDiamond 8800 family backup MSM diagnostics, 188 BlackDiamond 8800 family I/O module diagnostics, 186 BlackDiamond 8800 family primary MSM diagnostics, 187 MSM-1 diagnostics, 186 MSM-1XL, 186 Summit X450 switch diagnostics, 188 licenses, 33 link aggregation, 119 LLDP, 148, 149 load sharing, 119, 124 memory, 105 module recovery, 195 MSM and I/O ports same module, 111 MSM prompt, 616 MSM-1 diagnostics, 633 MSM-1XL diagnostics, 633 passwords, 50 path MTU discovery, 117 ping, 54 PoE, 164, 165, 170, 171 port configuration, 617 port-mirroring, 130, 131 power fluctuation on PoE module, 633 QoS, 292, 298, 300, 303, 304 rescue image, 623 software, 33 software-controlled redundant ports, 137 SSH2, 336 SSL, 48 SSL commands, 340 STP, 447, 618 system LEDs, 612 TFTP server, 69, 629 traceroute, 54 untagged frames on 10Gbps module, 633 virtual routers, 29 VLANs, 221, 224, 229, 618 VMANs, 116, 233 VRRP, 494, 620 VRRP and ESRP, 494 trunks, 223 tunneling IP, 524 See also VMANs VMANs, 238 Type of Service. See TOS

U
UDP echo server, 513 untagged frames, VLANs, 221, 229 upgrading the image, 593 uploading the configuration, 603 upstream forwarding, 254 URL redirection, 346 user account, 48 user name, local database authentication, 355 user name, SNMPv3, 87 user sessions, 59 See also sessions user virtual routers, 243 User-Based Security Model. See USM users access levels, 47 adding, 49 authenticating, 62, 322 creating, 49 default, 48 deleting, 49 passwords, 50 viewing, 49 USM, SNMPv3 security, 86 utilization port, 140

V
vendor ID, 352 Vendor Specific Attribute. See VSA version string, 592 video applications, and QoS, 290 View-Based Access Control Model, SNMPv3, 89 Virtual LANs. See VLANs virtual link, OSPF, 548

ExtremeWare XOS 11.3 Concepts Guide

695

Index virtual link, OSPFv3, 559 virtual port, port-mirroring, 131 Virtual Router Redundancy Protocol. See VRRP virtual routers adding and deleting routing protocols, 245 and routing protocols, 245 and VLANs, 220 commands, 243 configuration domain, 243 configuration example, 246 configuring routing protocols and VLANs, 246 creating, 244 default for Telnet, 64 deleting, 244 description, 241 displaying information, 245 overview, 29 system, 242 troubleshooting, 28, 29 user, 243 VLAN tagging, 223 VLAN, guest. See guest VLAN VLANid, 223 VLANs and load sharing, 126 and STP, 424 and virtual routers, 220 assigning a tag, 224 assigning IP address, 229 benefits, 219 configuration examples, 229 configuring, 229 default tag, 224 description, 219 disabling route advertising, 533, 541 displaying IPv6 addresses, 231 displaying settings, 141, 230 IP fragmentation, 118 IPv4 routing, 500 IPv6 address, 230 IPv6 addresses, 219 IPv6 routing, 522 mgmt, 61 mixing port-based and tagged, 225 names, 41, 228 port-based, 220223 precedence, 227 protocol filters customizing, 226 deleting, 227 predefined, 226 protocol-based, 225 QoS profile, 231 renaming, 228 tagged, 223 troubleshooting, 221, 224, 227, 229, 235, 618 trunks, 223 types, 220 untagged packets, 221, 224, 229 VLANid, 223 VMANs and EAPS, 238 and link aggregation, 119 and virtual routers, 234 assigning IP addresses, 232 configuring, 235 displaying, 238 displaying settings, 141 EtherTypes, 233 example, 236, 237 guidelines, 235 jumbo frames, 116, 233 multicasting, 234 names, 41 tagging ports, 233 troubleshooting, 119, 235 voice applications, and QoS, 290 VoIP network measurement, 636 VRRP advertisement interval, 488, 491 and ESRP, 484, 489, 494 and IP multinetting, 507 and STP, 489 configuration parameters (table), 491 default gateway, 485 description, 485 electing the master, 488 examples, 492493 IP address, 491 master down interval, 488, 491 master router determining, 485 electing, 488 multicast address, 488 operation, 489 ping tracking, 486, 487 preempt mode, 491 priority, 485, 488, 491 redundancy, 490 route table tracking, 486 skew time, 488, 491 tracking description, 486 example, 487 troubleshooting, 494, 620 virtual IP addresses, 494

696

ExtremeWare XOS 11.3 Concepts Guide

Index virtual router MAC address, 488, 489 VLAN tracking, 486, 487 VRRP virtual router identifier (VRID), 491 VSA definitions, 352 definitions (table), 352 order of use, 353 VSA 203 example, 354 guidelines, 354 VSA 204 example, 355 guidelines, 354 VSA 205 example, 355 guidelines, 355 VSA 206 examples, 352 guidelines, 355 VSA 209 example, 354 guidelines, 354 VSA 211 examples, 353 guidelines, 353

W
web browsing applications, and QoS, 291 web-based authentication, 363 advantages, 346 configuration, example, 365 disabling, 364 disadvantages, 347 enabling, 364 requirements, 346 URL redirection, 346 user login setup, 367 wildcard combinations, port, 43, 112

X
XML, 102 XML configuration mode, 102

ExtremeWare XOS 11.3 Concepts Guide

697

Index

698

ExtremeWare XOS 11.3 Concepts Guide

S-ar putea să vă placă și