Antenna Line Products

version 3
Your partner in quality cable solutions Draka NK Cables Ltd. P.O.Box 419, FIN-00101 Helsinki, FINLAND Tel. +358 10 5661, Fax +358 9 529 841 www.drakankc.fi
6/2004

www.drakacomteq.com

Draka NK Cables
Jumper cable

Feeder cable + connector

The roots of the company date back to 1912 when a cord factory was established in Helsinki. After those times both the name and the owners have changed, but the manufacturing of high quality cables continues. We have built on our strengths from the early days, and in course of the time developed into a strong international company. Since 1999 we are part of the Draka Group. Our parent company, Draka Holding based in Amsterdam, is one of Europes leading cable companies in communication and installation cables.
NK CABLES branded radio frequency

activities by complying with the principles of sustainable development. We are a proven antenna line supplier with network provider and operator experience on all continents. Our production facilities are located in Finland, China and Brazil, focusing their products in the respective home and neighbouring markets. An extensive sales network serves our customers worldwide.

cables have been designed to meet the highest quality and environmental standards. We take the environment into consideration in all our

Cable clamp

Contents
General Information on 50 Ohm Radio Frequency Cables
NK CABLES 50 Ohm Radio Frequency Cables

4 5 6-19 20-31 32-33 34-35 36-37 38-39 40-43

Feeder Cables
Grounding kit

Superflexible Cables Jumpers Accessories Drums Environment and Quality Codes

EMP Protector

All information in this catalog is subject to change without prior notice.

Cables
All our cables are halogen free, non corrosive and can be manufactured with fire retardant and low smoke emission jacket in black (BHF) or grey (GHF). In addition to the products presented in this catalog, we supply coaxial antennas for tunnels and indoor solutions.

General Information on 50 Ohm Radio Frequency Cables


Feeder cables are typically used for mobile telecommunication applications, such as GSM, WCDMA (UMTS), TDMA, D-AMPS, PCN, CDMA and TETRA. The function of the feeder cable is to transmit signal power between the transmission equipment and the antenna in all environmental conditions. The superflexible RFF cables are typically used as jumpers to connect the feeder cable to the transmission equipment or to the antenna in mobile telecommunication applications. The extraflexible RFE cables can be used for indoor and rooftop applications due to their excellent bending performance. In some cases RFE cables can eliminate the use of jumpers. Low attenuation at high frequencies, uniform impedance and low return loss are the most important qualities of NK CABLES branded radio frequency cables. In addition, our BHF jacketed RF cables pass the UL 1666 Flame test and can be supplied with a UL Rating of CATVR.

NK CABLES 50 Ohm Radio Frequency Cables


FEEDER CABLES Type Product code Inner conductor diam. (mm) 3.1 4.8 7.0 9.0 13.0 17.5 21.2 Outer conductor diam. (mm) 9.5 13.9 19.7 24.9 35.8 46.5 55.9 Jacket diam. (mm) Standard length (m) Standard Drum type P6D P11D P14G P14G P21G P21G P21Q

RF 3/8"-50 RF 1/2"-50 RF 5/8"-50 RF 7/8"-50 RF 1 1/4"-50 RF 1 5/8"-50 RF 2 1/4"-50

NKRF03800 NKRF01200 NKRF05800 NKRF07800 NKRF11400 NKRF15800 NKRF21400

11.2 16.0 21.9 27.5 39.0 50.0 60.0

250 500 500 500 600 400 300

SUPERFLEXIBLE CABLES Type Product code Inner conductor diam. (mm) 1.9 2.6 3.55 9.4 13.6 17.5 Outer conductor diam. (mm) 6.4 9.0 11.9 24.9 35.8 46.5 Jacket diam. (mm) Standard length (m) Standard Drum type 5C 5C P11D P14G P21G P21G

RFF 1/4"-50 RFF 3/8"-50 RFF 1/2"-50 RFE 7/8"-50 RFE 1 1/4"-50 RFE 1 5/8"-50

NKRFF01400 NKRFF03800 NKRFF01200 NKRFE07800 NKRFE11400 NKRFE15800

7.4 10.1 13.5 27.5 39.0 50.0

250 250 500 500 600 400

RF 3/8 -5 0

Feeder cable

RF 3/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 3.1 mm 8.0 mm 9.5 mm 11.2 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 126 kg/km 1650 N 50 mm 95 mm -55...+80C 2.0 kg/mm 2.1 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.86 78 pF/m 14 000 MHz see table 1.2 kV 16.1 kW 3.6 /km 3.1 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RF 3/8"-50 RF 3/8"-50 GHF RF 3/8"-50 BHF RF 3/8"-50 BHF

NKRF03800 NKRF03801 NKRF03802 NKRF03804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 13500

1.03 1.79 2.32 3.10 3.31 3.45 4.41 4.74 5.86 6.81 7.25 7.66 7.76 8.44 9.16 9.84 10.2 10.4 10.5 10.8 10.9 11.1 12.3 13.3 14.4 15.3 15.8 16.2 17.1 18.0 18.8 19.6 20.4 21.9 30.4 49.7

Attenuation dB/100 m

7.0 3.9 3.0 2.2 2.1 2.0 1.6 1.5 1.2 1.0 1.0 0.90 0.89 0.82 0.76 0.70 0.68 0.67 0.66 0.64 0.64 0.63 0.57 0.52 0.49 0.46 0.44 0.43 0.41 0.39 0.37 0.36 0.34 0.32 0.23 0.15

STANDARD DRUM
Cable type Standard drum name P6D Standard length m RF 3/8" 250 Outer diam. cm 60 Outer width cm 51 Drum weight kg 14 Total weight kg 46 Drum freight volume m3 0.18

UV retardancy

IEC 61034 low smoke emission

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

RF 1/2 -5 0

Feeder cable

RF 1/2-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 4.8 mm 12.1 mm 13.9 mm 16.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 250 kg/km 2550 N 70 mm 120 mm -55...+80C 2.0 kg/mm 3.8 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 10 000 MHz see table 1.80 kV 31.8 kW 1.43 /km 1.99 /km 50 1

RF 1/2"-50 RF 1/2"-50 GHF RF 1/2"-50 BHF RF 1/2"-50 BHF

NKRF01200 NKRF01201 NKRF01202 NKRF01204

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

Min. installation temperature

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 8800

0.669 1.17 1.51 2.02 2.16 2.25 2.88 3.09 3.83 4.45 4.74 5.01 5.08 5.53 6.01 6.45 6.67 6.84 6.88 7.09 7.13 7.29 8.05 8.77 9.44 10.1 10.4 10.7 11.3 11.9 12.4 12.9 13.5 14.5 20.2 25.5

Attenuation dB/100 m

12 6.9 5.3 4.0 3.7 3.6 2.8 2.6 2.1 1.8 1.7 1.6 1.6 1.4 1.3 1.2 1.2 1.2 1.2 1.1 1.1 1.1 0.99 0.90 0.84 0.79 0.76 0.74 0.70 0.66 0.63 0.61 0.58 0.54 0.39 0.31

STANDARD DRUM
Cable type Standard drum name P11D Standard length m RF 1/2" 500 Outer diam. cm 114 Outer width cm 55 Drum weight kg 43 Total weight kg 168 Drum freight volume m3 0.71

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

RF 5

/8 -

Feeder cable

50

RF 5/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 7.0 mm 17.6 mm 19.7 mm 21.9 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 410 kg/km 3750 N 90 mm 150 mm -55...+80C 1.6 kg/mm 4.4 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 6800 MHz see table 2.50 kV 64.3 kW 1.23 /km 1.09 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RF 5/8"-50 RF 5/8"-50 GHF RF 5/8"-50 BHF RF 5/8"-50 BHF

NKRF05800 NKRF05801 NKRF05802 NKRF05804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 6100

0.460 0.803 1.04 1.39 1.49 1.55 1.99 2.14 2.64 3.08 3.28 3.47 3.52 3.83 4.16 4.48 4.63 4.75 4.77 4.92 4.95 5.06 5.60 6.10 6.57 7.02 7.24 7.46 7.87 8.27 8.66 9.04 9.41 10.1 14.2 14.4

Attenuation dB/100 m

19 11 8.3 6.2 5.8 5.6 4.3 4.0 3.3 2.8 2.6 2.5 2.4 2.2 2.1 1.9 1.9 1.8 1.8 1.8 1.7 1.7 1.5 1.4 1.3 1.2 1.2 1.2 1.1 1.0 0.99 0.95 0.91 0.85 0.60 0.60

STANDARD DRUM
Cable type Standard drum name P14G Standard length m RF 5/8" 500 Outer diam. cm 144 Outer width cm 74 Drum weight kg 98 Total weight kg 303 Drum freight volume m3 1.53

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

10

11

RF 7

/8 -

Feeder cable

50

RF 7/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 9.0 mm 22.2 mm 24.9 mm 27.5 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 530 kg/km 3200 N 120 mm 250 mm -55...+80C 1.7 kg/mm 16.2 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 5300 MHz see table 3.2 kV 94.8 kW 1.04 /km 1.00 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RF 7/8"-50 RF 7/8"-50 GHF RF 7/8"-50 BHF RF 7/8"-50 BHF

NKRF07800 NKRF07801 NKRF07802 NKRF07804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4000 5000

0.360 0.629 0.817 1.09 1.17 1.21 1.56 1.67 2.07 2.42 2.57 2.72 2.75 3.00 3.26 3.51 3.63 3.72 3.74 3.86 3.87 3.97 4.39 4.78 5.15 5.51 5.68 5.85 6.18 6.49 6.80 7.09 7.38 7.95 8.75 10.0

Attenuation dB/100 m

26 15 12 8.5 8.0 7.7 6.0 5.6 4.5 3.8 3.6 3.4 3.4 3.1 2.8 2.6 2.5 2.5 2.5 2.4 2.4 2.3 2.1 1.9 1.8 1.7 1.6 1.6 1.5 1.4 1.3 1.3 1.2 1.1 1.0 0.9

STANDARD DRUM
Cable type Standard drum name P14G Standard length m RF 7/8" 500 Outer diam. cm 144 Outer width cm 74 Drum weight kg 98 Total weight kg 363 Drum freight volume m3 1.53

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

(UL) CATVR E205016

12

13

RF 1

1/4

Feeder cable

-50

RF 1 1/4-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 13.0 mm 32.2 mm 35.8 mm 39.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 940 kg/km 6050 N 200 mm 350 mm -55...+80C 2.5 kg/mm 48.7 Nm 1.5 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 3700 MHz see table 4.6 kV 211.2 kW 0.64 /km 0.55 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RF 1 1/4"-50 RF 1 1/4"-50 GHF RF 1 1/4"-50 BHF RF 1 1/4"-50 BHF


(UL) CATVR E205016

NKRF11400 NKRF11401 NKRF11402 NKRF11404

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3300

0.250 0.439 0.571 0.766 0.819 0.852 1.10 1.18 1.47 1.72 1.83 1.94 1.97 2.15 2.34 2.53 2.61 2.68 2.70 2.79 2.80 2.87 3.18 3.48 3.76 4.03 4.16 4.29 4.54 4.79 5.02 5.26 5.48 5.81

Attenuation dB/100 m

41 23 18 13 12 12 9.2 8.5 6.8 5.8 5.4 5.1 5.1 4.6 4.2 3.9 3.8 3.7 3.7 3.6 3.6 3.5 3.1 2.8 2.6 2.4 2.4 2.3 2.2 2.0 1.9 1.9 1.8 1.7

STANDARD DRUM
Cable type Standard drum name Standard length m RF 1 1/4" P21G 600 Outer diam. cm 214 Outer width cm 74 Drum weight kg 202 Total weight kg 766 Drum freight volume m3 3.39

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

14

15

RF 1

5/8

Feeder cable

-50

RF 1 5/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Corrugated copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 17.5 mm 42.0 mm 46.5 mm 50.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 1350 kg/km 3750 N 250 mm 500 mm -55...+80C 2.2 kg/mm 53.8 Nm 1.5 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 2800 MHz see table 5.6 kV 320.1 kW 0.73 /km 0.30 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

UV retardancy

IEC 61034 low smoke emission

JACKET

CODE

TYPE

Min. installation temperature

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600

0.197 0.346 0.452 0.610 0.653 0.680 0.880 0.950 1.19 1.40 1.49 1.59 1.61 1.76 1.93 2.08 2.16 2.22 2.23 2.30 2.32 2.38 2.65 2.91 3.16 3.40 3.51 3.63 3.85 4.07 4.28

Attenuation dB/100 m

57 32 25 18 17 16 12 12 9.3 7.9 7.4 7.0 6.8 6.2 5.7 5.3 5.1 4.9 4.9 4.8 4.7 4.6 4.1 3.8 3.5 3.2 3.1 3.0 2.8 2.7 2.5

STANDARD DRUM
Cable type Standard drum name Standard length m RF 1 5/8" P21G 400 Outer diam. cm 214 Outer width cm 74 Drum weight kg 202 Total weight kg 742 Drum freight volume m3 3.39

RF 1 5/8"-50

NKRF15800

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

RF 1 5/8"-50 GHF NKRF15801 RF 1 5/8"-50 BHF NKRF15802 RF 1 5/8"-50 BHF NKRF15804


(UL) CATVR E205016

16

17

RF 2

1/4

Feeder cable

-50

RF 2 1/4-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductorr Jacketing Marking Corrugated copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 21.2 mm 52.0 mm 55.9 mm 60.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 2000 kg/km 6950 N 270 mm 550 mm -55...+80C 3.4 kg/mm 94.5 Nm 1.5 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customer's specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 2400 MHz see table 6.6 kV 449.4 kW 0.48 /km 0.21 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

IEC 61034 low smoke emission

UV retardancy

JACKET

Min. installation temperature

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200

0.167 0.295 0.386 0.523 0.560 0.584 0.758 0.819 1.03 1.21 1.30 1.38 1.40 1.53 1.68 1.82 1.89 1.94 1.95 2.02 2.03 2.08 2.33 2.56 2.79 3.01 3.11 3.22 3.42

Attenuation dB/100 m

72 41 31 23 21 20 16 15 12 9.8 9.2 8.6 8.5 7.7 7.1 6.5 6.3 6.1 6.1 5.9 5.8 5.7 5.1 4.6 4.2 3.9 3.8 3.7 3.4

STANDARD DRUM
Cable type Standard drum name Standard length m RF 2 1/4" P21Q 300 Outer diam. cm 214 Outer width cm 112 Drum weight kg 213 Total weight kg 813 Drum freight volume m3 5.13

CODE

TYPE

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

RF 2 1/4"-50 RF 2 1/4"-50 GHF RF 2 1/4"-50 BHF

NKRF21400 NKRF21401 NKRF21402

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes

no yes yes

no yes yes

yes no yes

-20C -5C -5C

18

19

RFF 1/4 -5 0

Superflexible cable

RFF 1/4-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 1.9 mm 4.8 mm 6.4 mm 7.4 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 74 kg/km 780 N 12.5 mm 25 mm -55...+80C 2.3 kg/mm 1.1 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance 50 2

Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.83 80 pF/m 21000 MHz see table 0.74 kV 6.5 kW 9.8 /km 7.7 /km

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RFF 1/4"-50 RFF 1/4"-50 GHF RFF 1/4"-50 BHF RFF 1/4"-50 BHF
(UL) CATVR E205016

NKRFF01400 NKRFF01501 NKRFF01402 NKRFF01404

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 20400

1.78 3.10 4.02 5.35 5.71 5.94 7.58 8.14 10.0 11.6 12.4 13.1 13.2 14.4 15.6 16.7 17.3 17.7 17.8 18.3 18.4 18.8 20.7 22.5 24.1 25.7 26.5 27.2 28.6 30.0 31.4 32.6 33.9 36.3 49.8 102

Attenuation dB/100 m

3.4 2.0 1.5 1.1 1.1 1.0 0.81 0.75 0.61 0.53 0.49 0.47 0.46 0.43 0.39 0.37 0.35 0.35 0.34 0.33 0.33 0.32 0.29 0.27 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.19 0.18 0.17 0.12 0.06

STANDARD DRUM
Cable type Standard drum name P5C Standard length m RFF 1/4" 250 Outer diam. cm 54 Outer width cm 50 Drum weight kg 12 Total weight kg 31 Drum freight volume m3 0.15

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

20

21

RFF 3/8 -5 0

Superflexible cable

RFF 3/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 2.6 mm 6.5 mm 9.0 mm 10.1 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 130 kg/km 500 N 13 mm 25 mm -55...+80C 3.3 kg/mm 2.3 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.81 82 pF/m 15200 MHz see table 1.04 kV 13.2 kW 5.1 /km 6.1 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RFF 3/8"-50 RFF 3/8"-50 GHF RFF 3/8"-50 BHF RFF 3/8"-50 BHF
(UL) CATVR E205016

NKRFF03800 NKRFF03801 NKRFF03802 NKRFF03804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 13400

1.32 2.29 2.98 3.97 4.24 4.42 5.65 6.08 7.51 8.74 9.30 9.84 9.96 10.8 11.8 12.7 13.1 13.4 13.5 13.9 14.0 14.3 15.8 17.2 18.5 19.7 20.3 20.9 22.1 23.2 24.3 25.3 26.3 28.3 39.5 64.5

Attenuation dB/100 m

6.2 3.6 2.7 2.1 1.9 1.9 1.5 1.3 1.1 0.93 0.87 0.83 0.83 0.75 0.69 0.64 0.62 0.62 0.60 0.58 0.60 0.57 0.51 0.47 0.44 0.41 0.40 0.39 0.37 0.35 0.33 0.32 0.31 0.29 0.20 0.12

STANDARD DRUM
Cable type Standard drum name P5C Standard length m RFF 3/8" 250 Outer diam. cm 54 Outer width cm 50 Drum weight kg 12 Total weight kg 45 Drum freight volume m3 0.15

UV retardancy

IEC 61034 low smoke emission

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

22

23

RFF 1

/2

-50

Superflexible cable

RFF 1/2-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Copper-clad aluminium wire Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 3.55 mm 9.0 mm 11.9 mm 13.5 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 190 kg/km 900 N 15 mm 30 -55...+80C 3.4 kg/mm 2.7 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.82 82 pF/m 12500 MHz see table 1.39 kV 19.0 kW 2.73 /km 4.11 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RFF 1/2"-50 RFF 1/2"-50 GHF RFF 1/2"-50 BHF RFF 1/2"-50 BHF
(UL) CATVR E205016

NKRFF01200 NKRFF01201 NKRFF01202 NKRFF01204

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 6000 10200

0.98 1.71 2.22 2.96 3.16 3.29 4.22 4.53 5.60 6.52 6.94 7.34 7.44 8.09 8.79 9.45 9.77 10.0 10.1 10.4 10.4 10.7 11.8 12.8 13.8 14.8 15.2 15.7 16.5 17.3 18.2 18.9 19.7 21.2 29.6 40.8

Attenuation dB/100 m

7.8 4.5 3.5 2.6 2.4 2.3 1.8 1.7 1.4 1.2 1.1 1.0 1.0 0.94 0.86 0.80 0.78 0.76 0.75 0.73 0.73 0.71 0.64 0.59 0.55 0.51 0.50 0.48 0.46 0.43 0.41 0.40 0.38 0.36 0.25 0.18

STANDARD DRUM
Cable type Standard drum name P11D Standard length m RFF 1/2" 500 Outer diam. cm 114 Outer width cm 55 Drum weight kg 43 Total weight kg 138 Drum freight volume m3 0.71

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

24

25

Extraflexible cable

RFE 7/8 -5 0

RFE 7/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Corrugated copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 9.4 mm 21.7 mm 24.9 mm 27.5 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 434 kg/km 1500 N 90 mm 120 mm -55...+80C 1.6 kg/mm 15.7 Nm 1.0 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 74.3 pF/m 5400 MHz see table 2.8 kV 91.3 kW 2.50 /km 1.05 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RFE 7/8"-50 RFE 7/8"-50 GHF RFE 7/8"-50 BHF RFE 7/8"-50 BHF
(UL) CATVR E205016

NKRFE07800 NKRFE07801 NKRFE07802 NKRFE07804

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes yes

no yes yes yes

no yes yes yes

yes no yes yes

-40C -5C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3400 4900

0.382 0.668 0.868 1.16 1.24 1.29 1.66 1.78 2.21 2.58 2.75 2.91 2.95 3.21 3.49 3.76 3.89 3.99 4.01 4.13 4.16 4.25 4.71 5.14 5.54 5.92 6.11 6.29 6.65 6.99 7.33 7.65 7.97 8.58 10.7

Attenuation dB/100 m

23 13 10 7.8 7.0 6.9 5.4 5.0 4.0 3.4 3.2 3.1 3.0 2.8 2.5 2.4 2.3 2.2 2.2 2.2 2.1 2.1 1.9 1.7 1.6 1.5 1.5 1.4 1.3 1.3 1.2 1.2 1.1 1.0 0.83

STANDARD DRUM
Cable type Standard drum name P14G Standard length m RFE 7/8" 500 Outer diam. cm 144 Outer width cm 74 Drum weight kg 98 Total weight kg 315 Drum freight volume m3 1.53

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

26

27

RFE 1

1/4

-50

Extraflexible cable

RFE 1 1/4-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Corrugated copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 13.6 mm 32.2 mm 35.8 mm 39.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 837 kg/km 5100 N 120 mm 220 mm -55...+80C 2.3 kg/mm 30.2 Nm 1.5 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 3700 MHz see table 4.5 kV 187.2 kW 1.24 /km 0.59 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

RFE 1 1/4"-50 RFE 1 1/4"-50 GHF RFE 1 1/4"-50 BHF

NKRFE11400 NKRFE11401 NKRFE11402

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes

no yes yes

no yes yes

yes no yes

-40C -5C -5C

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600 2800 3000 3300

0.251 0.441 0.575 0.773 0.827 0.862 1.11 1.20 1.49 1.75 1.87 1.98 2.01 2.20 2.40 2.59 2.68 2.75 2.77 2.86 2.87 2.94 3.27 3.48 3.88 4.17 4.30 4.44 4.71 4.96 5.21 5.46 5.70 6.05

Attenuation dB/100 m

36 21 16 12 11 11 8.3 7.7 6.2 5.3 4.9 4.6 4.6 4.2 3.8 3.6 3.4 3.4 3.3 3.2 3.2 3.1 2.8 2.6 2.4 2.2 2.2 2.1 2.0 1.9 1.8 1.7 1.6 1.5

STANDARD DRUM
Cable type Standard drum name Standard length m RFE 1 1/4" P21G 600 Outer diam. cm 214 Outer width cm 74 Drum weight kg 202 Total weight kg 704 Drum freight volume m3 3.39

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

28

29

RFE 1

5/8

-50

Extraflexible cable

RFE 1 5/8-50
Specifications
CONSTRUCTION Inner conductor Dielectric Outer conductor Jacketing Marking Corrugated copper tube Cellular polyethylene Corrugated copper tube See table below NK Cables, cable type, manufacture week, year, batch number and meter mark 17.5 mm 42.0 mm 46.5 mm 50.0 mm ATTENUATION
Power rating kW

MECHANICAL CHARACTERISTICS Weight Maximum pulling force Minimum bending radius Single bending Repeated bending Operating temperature range Crush resistance Bending moment Recommended clamp distance 1300 kg/km 2700 N 200 mm 350 mm -55...+80C 2.1 kg/mm 48.1 Nm 1.5 m

Frequency

ELECTRICAL CHARACTERISTICS at +20C Characteristic impedance Return loss 24 dB for 100 m cable with NKC connectors Bands according to customers specifications 380500 MHz 806960 MHz 17101880 MHz 19002170 MHz Other bands also available on request Attenuation Velocity factor Capacitance Maximum frequency Max power rating Peak RF voltage rating Peak power rating DC resistance Inner conductor Outer conductor see table 0.88 76 pF/m 2800 MHz see table 5.0 kV 284.0 kW 1.23 /km 0.38 /km 50 1

IEC 60754 -1/-2 halogen free, non corrosive

IEC 60332-3 C fire retardant

JACKETING OPTIONS

IEC 61034 low smoke emission

UV retardancy

JACKET

CODE

TYPE

Min. installation temperature

10 30 50 88 100 108 174 200 300 400 450 500 512 600 700 800 850 890 900 950 960 1000 1200 1400 1600 1800 1900 2000 2200 2400 2600

0.198 0.349 0.456 0.615 0.659 0.686 0.889 0.959 1.19 1.41 1.51 1.60 1.63 1.76 1.95 2.11 2.19 2.25 2.26 2.34 2.35 2.41 2.69 2.95 3.21 3.45 3.57 3.68 3.91 4.14 4.35

Attenuation dB/100 m

57 32 25 18 17 16 12 12 9.3 7.9 7.4 7.0 6.8 6.2 5.7 5.3 5.1 4.9 4.9 4.8 4.7 4.6 4.1 3.8 3.5 3.2 3.1 3.0 2.8 2.7 2.5

STANDARD DRUM
Cable type Standard drum name Standard length m RFE 1 5/8" P21G 400 Outer diam. cm 214 Outer width cm 74 Drum weight kg 202 Total weight kg 722 Drum freight volume m3 3.39

RFE 1 5/8"-50

NKRFE15800

Black polyethylene, halogen free Grey, halogen free fire retardant thermoplastic Black, halogen free fire retardant thermoplastic

yes yes yes

no yes yes

no yes yes

yes no yes

-40C -5C -5C

Attenuation values are typical at ambient temperature +20C. Power rating ambient temperature +40C, inner conductor +100C.

RFE 1 5/8"-50 GHF NKRFE15801 RFE 1 5/8"-50 BHF NKRFE15802

30

31

Jum pe rs

Jumpers
NK jumper test report with return loss and intermodulation measurements. For traceability, a weatherproof ID label is attached to each jumper.

Jumpers with superflexible RFF 1/2" cable


Jumpers are typically used to connect the feeder cable to the transmission equipment or to the antenna in mobile telecommunication applications. The design of the assembly ensures the waterproofness of the jumper to IP 68. The soldered inner and outer conductor guarantees excellent return loss and low intermodulation. Highlights of NK jumpers Excellent return loss values with low and stable intermodulation Waterproof per IP68 water immersion testing specifications Test report with return loss and intermodulation measurements attached to each jumper Stable electrical performance is ensured by high quality superflexible cable and special connector head design. The design is based on three main principles ensuring compliance with water immersion testing: 7-16 head sealing with O-rings induction soldering of the inner and outer conductors providing 360 degrees of contact and sealing enclosing the connection at the rear of the connector with injection molded plastic providing the external waterproof seal and stain relief Additional protection is maintained during storage and transport by a watertight protective cap on each end.

Connectors
Male 7/16 Male 7/16

RFF 1/2cable length 0.5 m NKJ 11 NKJ 111 NKJ 121 NKJ 131 1m NKJ 112 NKJ 122 NKJ 132 1.5 m NKJ 113 NKJ 123 NKJ 133 2m NKJ 114 NKJ 124 NKJ 134 2.5 m NKJ 115 NKJ 125 NKJ 135 3m NKJ 116 NKJ 126 NKJ 136 4m 5m

NKJ 118 NKJ 1110 NKJ 128 NKJ 1210 NKJ 138 NKJ 1310

Male 7/16

Female 7/16

NKJ 12
Male 7/16 Male N

NKJ 13
Male 7/16 Female N

NKJ 14
Male 7/16 Male 7/16 90

NKJ 141

NKJ 142

NKJ 143

NKJ 144

NKJ 145

NKJ 146

NKJ 148 NKJ 1410

NKJ 15
Male 7/16 Male N 90

NKJ 151

NKJ 152

NKJ 153

NKJ 154

NKJ 155

NKJ 156

NKJ 158 NKJ 1510

NKJ 16
Female 7/16 Female 7/16

NKJ 161 NKJ 221 NKJ 231 NKJ 241

NKJ 162 NKJ 222 NKJ 232 NKJ 242

NKJ 163 NKJ 223 NKJ 233 NKJ 243

NKJ 164 NKJ 224 NKJ 234 NKJ 244

NKJ 165 NKJ 225 NKJ 235 NKJ 245

NKJ 166 NKJ 226 NKJ 236 NKJ 246

NKJ 168 NKJ 1610 NKJ 228 NKJ 2210 NKJ 238 NKJ 2310 NKJ 248 NKJ 2410

NKJ 22
Female 7/16 Male N

NKJ 23
Female 7/16 Female N

NKJ 24
Female 7/16 Male 7/16 90

NKJ 25
Female 7/16 Male N 90

NKJ 251

NKJ 252

NKJ 253

NKJ 254

NKJ 255

NKJ 256

NKJ 258 NKJ 2510

NKJ 26
Male N Male N

NKJ 261 NKJ 331 NKJ 341

NKJ 262 NKJ 332 NKJ 342

NKJ 263 NKJ 333 NKJ 343

NKJ 264 NKJ 334 NKJ 344

NKJ 265 NKJ 335 NKJ 345

NKJ 266 NKJ 336 NKJ 346

NKJ 268 NKJ 2610 NKJ 338 NKJ 3310 NKJ 348 NKJ 3410

NKJ 33
Male N Female N

NKJ 34
Male N Male 7/16 90

NKJ 35
Male N Male N 90

NKJ 351

NKJ 352

NKJ 353

NKJ 354

NKJ 355

NKJ 356

NKJ 358 NKJ 3510

NKJ 36
Female N Female N

NKJ 361 NKJ 441

NKJ 362 NKJ 442

NKJ 363 NKJ 443

NKJ 364 NKJ 444

NKJ 365 NKJ 445

NKJ 366 NKJ 446

NKJ 368 NKJ 3610 NKJ 448 NKJ 4410

NKJ 44
Female N Male 7/16 90

NKJ 45
Female N Male N 90

NKJ 451

NKJ 452

NKJ 453

NKJ 454

NKJ 455

NKJ 456

NKJ 458 NKJ 4510

NKJ 46

NKJ 461

NKJ 462

NKJ 463

NKJ 464

NKJ 465

NKJ 466

NKJ 468 NKJ 4610

Fire retardant jumpers for indoor applications also available, for instance NKJ112BHF and NKJ112GHF. Also other lengths are available.

32

33

Acc ess ori es

Accessories

Connectors Low intermodulation Primary weatherproofness with O-ring technology

Tools Reduced assembly time Guarantee of constant assembly quality

For radio frequency cables Draka NK Cables offers factory designed accessories that are easy to install and reliable in any environmental conditions. Connectors, tools, grounding kits and EMP-protectors are specified below. For other accessories please contact Draka NK Cables sales personnel.

Grounding kits Fast and easy to install Waterproof per IP 68 Reusable

EMP-Protectors One-piece, easy and rapid installation No maintenance required

EMP Protector Product Code Frequency range Broadband quarter-wave EMP-protector NKA3000 800 f 2170 MHz

FEEDER CABLES Connectors 7-16 male 7-16 female 7-16 male right angle N-male N-female N-male right angle RF 3/8 RF 1/2 RF 5/8 NKC1058100 NKC1058200 NKC1058300 NKC1058400 RF 7/8 NKC1078100 NKC1078200 NKC1078500 NKC1078300 NKC1078400 RF 1 1/4 NKC1114100 NKC1114200 NKC1114300 NKC1114400 RF 1 5/8 NKC1158100 NKC1158200 NKC1158300 NKC1158400 RF 2 1/4 NKC1214100 NKC1214200 NKC1214300 NKC1214400

SUPERFLEXIBLE CABLES Connectors 7-16 male 7-16 female 7-16 male right angle N-male N-female N-male right angle RFF 1/4 NKC2014120 NKC2014220 NKC2014320 NKC2014420 NKC2014620 RFF 3/8 RFF 1/2 RFE 7/8 RFE 1 1/4 NKC1114100 NKC1114200 NKC1114300 NKC1114400 RFE 1 5/8 NKC1158100 NKC1158200 NKC1158300 NKC1158400

NKC1038100 NKC1012100 NKC1038200 NKC1012200 NKC1012500 NKC1038300 NKC1012300 NKC1038400 NKC1012400 NKC1012600

NKC2038120 NKC2012120 NKC1078100 NKC2038220 NKC2012220 NKC1078200 NKC2012520 NKC1078500 NKC2038320 NKC2012320 NKC1078300 NKC2038420 NKC2012420 NKC1078400 NKC2038620 NKC2012620

Grounding kits Grounding kit NKG103800 NKG101200 NKG105800 NKG107800 NKG111400 NKG115800 NKG121400

Grounding kits Grounding kit NKG203800 NKG201200 NKG107800 NKG111400 NKG115800

Tools Manual tools Drill tools Grounding kit tools


(Stripping length, mm)

Tools NKA1000 NKA1001 NKA12012 NKA1401222 (22) NKA1401226 (26) NKA1002 NKA12058 NKA1003 NKA12078 NKA1407822 (22) NKA1407826 (26) NKA1004 NKA12114 NKA1411422 (22) NKA1411430 (30) NKA1004 and NKA1005 NKA1005 NKA12158 NKA12214 NKA1415822 (22) NKA1415830 (30) Manual tools Drill tools Grounding kit tools
(Stripping length, mm)

NKA1007

NKA1008

NKA1009 NKA22012 NKA1401222 (22) NKA1401226 (26)

NKA1003

Grounding kit tools


(Stripping length, mm)

Grounding kit tools


(Stripping length, mm)

NKA1004 and NKA1005 NKA12078 NKA12114 NKA1407822 NKA1411422 (22) (22) NKA1407826 NKA1411430 (26) (30)

NKA1004 and NKA1005 NKA12158 NKA1415822 (22) NKA1415830 (30)

34

35

Dru ms

Drums
HANDLING INSTRUCTIONS FOR TRANSPORT

Only lift with a bar through the center.

When handling with a forklift; keep uppright.

Keep uppright, do not lay flat.

Roll according to the arrow.

STANDARD DRUMS FOR RF-CABLES

Wooden cable drums The drums are made of barkless boards or plywood The standard drum sizes are specified below Special drums can be supplied on request Impregnation available on request

Cable type

Standard Standard length drum name m P5C P5C P6D P11D P11D P14G P14G P14G P21G P21G P21G P21G P21Q 250 250 250 500 500 500 500 500 600 600 400 400 300

Optional length m 250 250275 250 400620 400600 400600 400622 400622 400607 400607 200400 200400 250350

Outer diam. (D) cm 54 54 60 114 114 144 144 144 214 214 214 214 214

Inner diam. (d) cm 25 25 33 70 70 80 80 80 130 130 130 130 150

Outer width (W) cm 50 50 51 55 55 74 74 74 74 74 74 74 112

Inner width (w) cm 40 40 43 43 43 61 61 61 61 61 61 61 97

Shaft hole (e) mm 82 82 82 82 82 82 82 82 82 82 82 82 82

Drum Cable weight weight kg 12 12 14 43 43 98 98 98 202 202 202 202 213 kg/m 0.074 0.130 0.126 0.250 0.190 0.410 0.530 0.434 0.940 0.837 1.350 1.300 2.000

Total weight kg 31 45 46 168 138 303 363 315 766 704 742 722 813

Drum freight volume m3 0.15 0.15 0.18 0.71 0.71 1.53 1.53 1.53 3.39 3.39 3.39 3.39 5.13

Drums to fit in 20 / 40 container 146 / 328 146 / 328 80 / 160 42 / 84 42 / 84 12 / 24 12 / 24 12 / 24 8 / 16 8 / 16 8 / 16 8 / 16 5 / 11

Handling and transport Handling instructions are attached on each drum The reeling direction of the cable is indicated by an arrow For transportation and storage the cable is protected by wooden (19 mm) lagging Plastic cover is placed on the drum under the cable and also over the outer layer of the cable, beneath the lagging Cable ends are sealed with a shrinkable plastic tube For detailed instructions for the handling of drums please see our multi-lingual booklet The right way to transport and move drums (in English, Spanish, Portuguese, French, Russian, Chinese, Arabic, Finnish, Swedish and German).

RFF 1/4" RFF 3/8" RF 3/8" RF 1/2" RFF 1/2" RF 5/8" RF 7/8" RFE 7/8" RF 1 1/4" RFE 1 1/4" RF 1 5/8" RFE 1 5/8" RF 2 1/4"

SPECIAL DRUMS FOR RF-CABLES

Cable type

Special drum name P16G P16G P22Q P19Q P19Q P22U P19Q P22U P22U

Max. length m

Outer diam. cm 164 164 220 194 194 220 194 220 220

Inner diam. cm 80 80 130 130 130 110 130 110 110

Outer width cm 74 74 118 106 106 130 106 130 130

Inner Shaft width hole cm 62.5 62.5 94 99 99 120 99 120 120 mm 82 82 82 82 82 82 82 82 82

Drum Drum weight freight volume kg m3 99 99 220 157 157 250 235 250 250 1.99 1.99 5.71 3.99 3.99 6.29 3.99 6.29 6.29

Drums to fit in 20 / 40 container 10 / 21 10 / 21 5 / 10 6 / 12 6 / 12 2/5 6 / 12 2/5 2/5

RF 7/8" RFE 7/8" RF 7/8" RF 1 1/4" RFE 1 1/4" RF 1 1/4" RF 1 5/8" RF 1 5/8" RFE 1 5/8"

937 937 2000 665 665 1200 400 1205 1205


Drum label shows cable type , length , weight and batch number .
36
D d e

w W

37

Environment and Quality

Env i and ronm Qu ent ali ty

Environmental Management System Draka NK Cables is committed to sustainable development. Operations and products are undergoing continuous development with an eye on reducing environmental load. Our environmental management system has been assessed, approved and audited regularly by Lloyds Register Quality Assurance to ISO 14001 Environmental Management System Standard. Environmental Statement

Quality Management System The quality management system of Draka NK Cables Ltd. has been assessed, approved and audited regularly by Lloyds Register Quality Assurance to ISO 9001 Quality Management System Standard. Compliance with ISO 9001:2000 standard guarantees the quality and continuous improvement of our processes. The quality management system of Draka NK Cables is open to customers evaluation. Quality Statement

Draka NK Cables Environmental Policy aims at Draka NK Cables commits to following environmental protection legislation and regulations reducing adverse environmental impacts during the whole life cycle preventing environmental pollution and increasing recovery and recycling raising environmental awareness of the entire personnel through training and reviewing encouraging material suppliers and contractors to sustainable development activities openly reporting the environmental impacts of its activities and products fulfilling customers needs in all processes providing customer satisfying products in due time performing customer service properly improving our processes constantly a quality concept covering everything from the products and services to overall operations

38

39

Co de s

Codes
NK code NKA1000 NKA1001 NKA1002 NKA1003 NKA1004 NKA1005 NKA1007 NKA1008 NKA1009 NKA3000 NKA3001 Product Cutting Tool for RF 3/8 cable Cutting Tool for RF 1/2 cable Cutting Tool for RF 5/8 cable Cutting Tool for RF 7/8 and RFE 7/8" cable Cutting Tool for RF / RFE 1 1/4 and RF / RFE 1 5/8 cable Cutting Tool for RFE 1 1/4, RF / RFE 1 5/8 and RF 2 1/4 cable Cutting Tool for RFF 1/4 cable Cutting Tool for RFF 3/8 cable Cutting Tool for RFF 1/2 cable EMP-protector, 800-2170 MHz, 7-16 m/f EMP-protector, 1710-1990 MHz, 7-16 m/f NK code NKA14000 NKA1401222 NKA1401226 NKA1407822 NKA1407826 NKA1411422 NKA1411430 NKA1415822 NKA1415830 Product T-Handles Stripping Tool for RF 1/2 Stripping tool for RF 1/2 Stripping Tool for RF 7/8 Stripping tool for RF 7/8 Stripping Tool for RF 1 1/4 Stripping tool for RF 1 1/4 Stripping Tool for RF 1 5/8 Stripping tool for RF 1 5/8 NK code NKC1114100 NKC1114200 NKC1114300 NKC1114400 NKC1158100 NKC1158200 NKC1012100 NKC1012200 NKC1012300 NKC1012400 NKA12012 NKA12058 NKA12078 NKA12114 NKA12158 NKA12214 NKA22012 Drill mounted cutting tool for RF 1/2" cable Drill mounted cutting tool for RF 5/8" cable Drill mounted cutting tool for RF 7/8" cable Drill mounted cutting tool for RF 1 1/4" cable Drill mounted cutting tool for RF 1 5/8" cable Drill mounted cutting tool for RF 2 1/4" cable Drill mounted cutting tool for RFF 1/2" cable NKC1012500 NKC1012600 NKC1038100 NKC1038200 NKC1038300 NKC1038400 NKC1058100 NKC1058200 NKA13000 NKA13001 Replacement blade for NKA1000-NKA1003 Replacement blade for NKA1004 and NKA1005 Replacement blade for NKA1007-NKA1009 Replacement blade for NKA12012 Replacement blade for NKA12058 Replacement blade for NKA12078 Replacement blade for NKA12114 Replacement blade for NKA12158 Replacement blade for NKA22012 NKC1058300 NKC1058400 NKC1078100 NKC1078200 NKC1078300 NKC1078400 NKC1078500 Connector 7-16 male for RF 1/2", O-ring Connector 7-16 female for RF 1/2, O-ring Connector N male for RF 1/2, O-ring Connector N female for RF 1/2, O-ring Connector 7-16 Right angle male for RF 1/2, O-ring Connector N Right angle male for RF 1/2, O-ring Connector 7-16 male for RF 3/8, O-ring Connector 7-16 female for RF 3/8, O-ring Connector N male for RF 3/8, O-ring Connector N female for RF 3/8, O-ring Connector 7-16 male for RF 5/8, O-ring Connector 7-16 female for RF 5/8, O-ring Connector N male for RF 5/8, O-ring Connector N female for RF 5/8, O-ring Connector 7-16 male for RF 7/8/RFE 7/8", O-ring Connector 7-16 female for RF 7/8"/RFE 7/8", O-ring Connector N male for RF 7/8"/RFE 7/8", O-ring Connector N female for RF 7/8"/RFE 7/8", O-ring Connector 7-16 Right angle male for RF 7/8"/RFE 7/8", O-ring NKC1158300 NKC1158400 NKC1214100 NKC1214200 NKC1214300 NKC1214400 Product Connector 7-16 male for RF 1 1/4" and RFE 1 1/4, O-ring Connector 7-16 female for RF 1 1/4 and RFE 1 1/4, O-ring Connector N male for RF 1 1/4 and RFE 1 1/4, O-ring Connector N female for RF 1 1/4 and RFE 1 1/4, O-ring Connector 7-16 male for RF 1 5/8", O-ring Connector 7-16 female for RF 1 5/8", O-ring Connector N male for RF 1 5/8", O-ring Connector N female for RF 1 5/8", O-ring Connector 7-16 male for RF 2 1/4", O-ring Connector 7-16 female for RF 2 1/4", O-ring Connector N male for RF 2 1/4", O-ring Connector N female for RF 2 1/4", O-ring NK code NKC2012120 NKC2012220 NKC2012320 NKC2012420 NKC2012520 NKC2012620 NKC2014120 NKC2014220 NKC2014320 NKC2014420 NKC2014620 NKC2038120 NKC2038220 NKC2038320 NKC2038420 NKC2038620 Product Connector 7-16 male for RFF 1/2 Connector 7-16 female for RFF 1/2 Connector N male for RFF 1/2 Connector N female for RFF 1/2 Connector 7-16 Right angle male for RFF 1/2 Connector N Right angle male for RFF 1/2 Connector 7-16 male for RFF 1/4, heat shrink sleeve Connector 7-16 female for RFF 1/4, heat shrink sleeve Connector N male for RFF 1/4, heat shrink sleeve Connector N female for RFF 1/4, heat shrink sleeve Connector N Right angle male for RFF 1/4, heat shrink sleeve Connector 7-16 male for RFF 3/8, heat shrink sleeve Connector 7-16 female for RFF 3/8, heat shrink sleeve Connector N male for RFF 3/8, heat shrink sleeve Connector N female for RFF 3/8, heat shrink sleeve Connector N Right angle male for RFF 3/8, heat shrink sleeve

NKA13002 NKA13012 NKA13058 NKA13078 NKA13114 NKA13158 NKA23012

40

41

Co de s

Codes
NK code NKD5C NKD6D NKDP11D NKDP14G NKDP16G NKDP19Q NKDP21G NKDP21Q NKDP22U NKDP22Q Product Drum P5C Drum P6D Drum P11D Drum P14G Drum P16G Drum P19Q Drum P21G Drum P21Q Drum P22U Drum P22Q NK code NKRF01200 NKRF01201 NKRF01202 NKRF01204 NKRF03800 NKRF03801 NKRF03802 NKRF03804 NKRF05800 NKRF05801 NKRF05802 NKRF05804 NKRF07800 NKRF07801 NKRF07802 NKRF07804 NKRF11400 NKRF11401 NKRF11402 NKRF15800 NKRF15801 NKRF15802 NKRF21400 NKRF21401 NKRF21402 Product Feeder cable RF 1/2-50 Feeder cable RF 1/2-50 GHF Feeder cable RF 1/2-50 BHF Feeder cable RF 1/2-50 BHF (UL) CATVR E205016 Feeder cable RF 3/8-50 Feeder cable RF 3/8-50 GHF Feeder cable RF 3/8-50 BHF Feeder cable RF 3/8-50 BHF (UL) CATVR E205016 Feeder cable RF 5/8-50 Feeder cable RF 5/8-50 GHF Feeder cable RF 5/8-50 BHF Feeder cable RF 5/8-50 BHF (UL) CATVR E205016 Feeder cable RF 7/8-50 Feeder cable RF 7/8-50 GHF Feeder cable RF 7/8-50 BHF Feeder cable RF 7/8-50 BHF (UL) CATVR E205016 Feeder cable RF 1 1/4-50 Feeder cable RF 1 1/4-50 GHF Feeder cable RF 1 1/4-50 BHF Feeder cable RF 1 5/8-50 Feeder cable RF 1 5/8-50 GHF Feeder cable RF 1 5/8-50 BHF Feeder cable RF 2 1/4-50 Feeder cable RF 2 1/4-50 GHF Feeder cable RF 2 1/4-50 BHF NK code NKRFE07800 NKRFE07801 NKRFE07802 NKRFE11400 NKRFE11401 NKRFE11402 NKRFE15800 NKRFE15801 NKRFE15802 NKRFF01200 NKRFF01201 NKRFF01202 NKRFF01204 NKRFF01400 NKRFF01402 NKRFF01404 NKRFF03800 NKRFF03802 NKRFF03804 Product Extraflexible cable RFE 7/8-50 Extraflexible cable RFE 7/8-50 GHF Extraflexible cable RFE 7/8-50 BHF (UL) CATVR E205016 Extraflexible cable RFE 1 1/4-50 Extraflexible cable RFE 1 1/4-50 GHF Extraflexible cable RFE 1 1/4-50 BHF Extraflexible cable RFE 1 5/8-50 Extraflexible cable RFE 1 5/8-50 GHF Extraflexible cable RFE 1 5/8-50 BHF Superflexible cable RFF 1/2-50 Superflexible cable RFF 1/2-50 GHF Superflexible cable RFF 1/2-50 BHF Superflexible cable RFF 1/2-50 BHF (UL) CATVR E205016 Superflexible cable RFF 1/4-50 Superflexible cable RFF 1/4-50 BHF Superflexible cable RFF 1/4-50 BHF (UL) CATVR E205016 Superflexible cable RFF 3/8-50 Superflexible cable RFF 3/8-50 BHF Superflexible cable RFF 3/8-50 BHF (UL) CATVR E205016

NKG101200 NKG103800 NKG105800 NKG107800 NKG111400 NKG115800 NKG121400

Grounding kit for RF 1/2 cable Grounding kit for RF 3/8 cable Grounding kit for RF 5/8 cable Grounding kit for RF 7/8 and RFE 7/8" cable Grounding kit for RF 1 1/4 and RFE 1 1/4 cable Grounding kit for RF 1 5/8 and RFE 1 5/8 cable Grounding kit for RF 2 1/4 cable