Sunteți pe pagina 1din 1

#### Nomenclature:

15-RV-006.361

Established Flow Condition

F2 A Ac N Ps T W1 Wm W M R = = = = = = = = = = = = = Selected Orifice Area (See Table 1) Ref: Orifice Letter: J Calculated Orifice Area (From Data Sht.) Number of Working Valves Set Pressure in "bara" Set Pressure in barg ( 13 ) + 1 bar Absolute Relief Temperature Relief Temperature in C ( 102 ) + 273.15K Ratio of Specific Heats = Cp/Cv Discharge Rate (From Data Sht.) Maximum Disch. Rate / Valve = Maximum Disch. Rate / Valve = Molecular Weight Gas Constant = 8.314 M = = = = = = = = = = = 830 602 1 14.00 375.15 1.2 mm mm bara K F1

F1 F1

F1 W1 . A N. Ac Wm 3600 101610.9 140095 38.92 18.46 0.45 kJ/kgK F2 9.81 m/s F3 Table 1 "A" Orifice Area (mm) 71 126 198 325 506 Formulae
F1 = 129 W 1000

Kg/h Kg/h Kg/s Only F2 is Effective, as other forces are balanced. At RV. Pop Condition

Acceleration due to Gravity

Size D E F G H

"A" Orifice Area (mm) 830 1186 1841 2323 2800

Size J K L M N

"A" Orifice Area (mm) 4116 7129 10323 16774

Size P Q R T F3 = 2F1

With Impact factor of 2

T + 1 )M

129 x 38.92 1000

1.2 x 375.15 (1.2+1) x 18.46 38.92 x 0.5 x 375.15 0.1 x 14 x 830

16.714

kN

F2 =

W R T 0.1xPs A

220.199

kN

F3 = 2 x F1

2 x 16.7

33.428

kN

7/16/2011 6:10 PM

PSV1 4112 RV-XXX Closed System