Sunteți pe pagina 1din 61

Aspen FLARENET

Getting Started Guide


Version Number: 2006.0
Month: October
Copyright (c) 2006 by Aspen Technology, Inc. All rights reserved.
Aspen Accounting.21™, Aspen ACOL™, Aspen Adsim®, Aspen Advisor™, Aspen Aerotran®, Aspen Alarm & Event™, Aspen APLE™,
Aspen Apollo™, Aspen AssetBuilder Optimizer™, Aspen AssetBuilder Planner™, Aspen AssetBuilder Site Optimizer™, Aspen
AssetBuilder™, Aspen Batch Plus®, Aspen Batch.21™, Aspen Batch.21™CBT, Aspen BatchCAD™, Aspen BatchSep™, Aspen Blend
Model Library™, Aspen Blend™, Aspen Calc™ CBT, Aspen Capable-to-Promise®, Aspen CatRef®, Aspen Chromatography®, Aspen
Cim-IO Interfaces™, Aspen Cim-IO Monitor™, Aspen Cim-IO™ for @AGlance, Aspen Cim-IO™ for ABB 1190, Aspen Cim-IO™ for
Bailey SemAPI, Aspen Cim-IO™ for DDE, Aspen Cim-IO™ for Eurotherm Gauge via CDP, Aspen Cim-IO™ for Fisher-Rosemount
Chip, Aspen Cim-IO™ for Fisher-Rosemount RNI, Aspen Cim-IO™ for Foxboro FOXAPI, Aspen Cim-IO™ for G2, Aspen Cim-IO™ for
GE FANUC via HCT, Aspen Cim-IO™ for Hitachi Ex Series, Aspen Cim-IO™ for Honeywell TDC 3000 via HTL/access, Aspen Cim-IO™
for Intellution Fix, Aspen Cim-IO™ for Measurex MCN, Aspen Cim-IO™ for Measurex ODX, Aspen Cim-IO™ for Moore Apacs via Nim
(RNI), Aspen Cim-IO™ for PI, Aspen Cim-IO™ for RSLinx, Aspen Cim-IO™ for SetCim/InfoPlus-X/InfoPlus.21, Aspen Cim-IO™ for
Toshiba Tosdic, Aspen Cim-IO™ for ULMA 3D, Aspen Cim-IO™ for Westinghouse, Aspen Cim-IO™ for WonderWare InTouch™,
Aspen Cim-IO™ for Yokogawa ACG10S, Aspen Cim-IO™ for Yokogawa EW3, Aspen Collaborative Forecasting™, Aspen
Compliance.21™, Aspen COMThermo TRC Database™, Aspen COMThermo®, Aspen Crude Trading & Marketing™, Aspen Custom
Modeler®, Aspen Decision Analyzer™, Aspen Demand Manager™, Aspen DISTIL™, Aspen Distribution Scheduler™, Aspen
DMCplus®, Aspen DMCplus® CBT, Aspen DMCplus® Composite, Aspen DPO™, Aspen Dynamics®, Aspen eBRS™, Aspen ERP
Connect®, Aspen FCC®, Aspen FIHR™, Aspen FLARENET™, Aspen Fleet Operations Management™, Aspen FRAN™, Aspen Fuel Gas
Optimizer™, Aspen Grade-IT™, Aspen Harwell Subroutine Library™, Aspen Hetran®, Aspen HTFS Research Network™, Aspen HX-
Net Operations™, Aspen HX-Net®, Aspen Hydrocracker®, Aspen Hydrotreater™, Aspen HYSYS Amines™, Aspen HYSYS Crude™,
Aspen HYSYS Data Rec™, Aspen HYSYS Dynamics™, Aspen HYSYS Johnson Matthey Reactor Models™, Aspen HYSYS OLGAS 3-
Phase™, Aspen HYSYS OLGAS™, Aspen HYSYS OLI Interface™, Aspen HYSYS Optimizer™, Aspen HYSYS Tacite™, Aspen HYSYS
Upstream Dynamics™, Aspen HYSYS Upstream™, Aspen HYSYS®, Aspen Icarus Process Evaluator®, Aspen Icarus Project
Manager®, Aspen InfoPlus.21®, Aspen Inventory Management & Operations Scheduling™, Aspen Inventory Planner™, Aspen
IQmodel Powertools™, Aspen IQ™, Aspen Kbase®, Aspen Lab.21, Aspen MBO™, Aspen MPIMS™, Aspen Multivariate Server™,
Aspen MUSE™, Aspen OnLine®, Aspen Operations Manager - Event Management™, Aspen Operations Manager - Integration
Infrastructure™, Aspen Operations Manager - Integration Infrastructure™ Aspen Advisor, Aspen Operations Manager - Integration
Infrastructure™ Aspen Orion, Aspen Operations Manager - Integration Infrastructure™ Aspen PIMS, Aspen Operations Manager -
Integration Infrastructure™ Aspen Utilities, Aspen Operations Manager - Integration Infrastructure™ Base, Aspen Operations
Manager - Integration Infrastructure™ COM, Aspen Operations Manager - Integration Infrastructure™ Files, Aspen Operations
Manager - Integration Infrastructure™ IP.21, Aspen Operations Manager - Integration Infrastructure™ IP.21/SAP-PPPI, Aspen
Operations Manager - Integration Infrastructure™ OPC, Aspen Operations Manager - Integration Infrastructure™ Relational
Databases, Aspen Operations Manager - Integration Infrastructure™ SAP R3, Aspen Operations Manager - Integration
Infrastructure™ System Monitoring, Aspen Operations Manager - Performance Scorecarding™, Aspen Operations Manager - Role
Based Visualization™ MS SharePoint, Aspen Operations Manager - Role Based Visualization™ TIBCO, Aspen Operations Tracking™,
Aspen Order Credit Management™, Aspen Orion Planning™, Aspen Orion XT™, Aspen PEP Process Library™, Aspen PIMS
Distributed Processing™, Aspen PIMS Enterprise Edition™, Aspen PIMS Global Optimization™, Aspen PIMS Mixed Integer
Programming™, Aspen PIMS Simulator Interface™, Aspen PIMS Solution Ranging™, Aspen PIMS Submodel Calculator™, Aspen
PIMS XNLP Optimizer™, Aspen PIMS™, Aspen PIPE™, Aspen Plant Planner & Scheduler™, Aspen Plant Scheduler Lite™, Aspen Plant
Scheduler™, Aspen Polymers Plus®, Aspen Plus OLI Interface™, Aspen Plus Optimizer™, Aspen Plus®, Aspen Plus® CBT, Aspen
PPIMS™, Aspen Process Explorer™ CBT, Aspen Process Manual™ Applied Rheology, Aspen Process Manual™ Bulk Solids Handling,
Aspen Process Manual™ Crystallization, Aspen Process Manual™ Drying, Aspen Process Manual™ Gas Cleaning, Aspen Process
Manual™ Internet Mode, Aspen Process Manual™ Intranet Mode, Aspen Process Manual™ Mini-Manuals, Aspen Process Manual™
Slurry Handling, Aspen Process Manual™ Solid Liquid Separation, Aspen Process Manual™ Solvent Extraction, Aspen Process
Manual™ Waste Water Treatment, Aspen Process Order™, Aspen Process Recipe®, Aspen Process Tools™, Aspen Production
Control Web Server™, Aspen ProFES® 2P Wax, Aspen ProFES® Tranflo, Aspen Profile.21™, Aspen Properties®, Aspen Pumper
Log™, Aspen Q Server™, Aspen Quality Management™, Aspen RefSYS CatCracker™, Aspen RefSYS™, Aspen Report Writer™, Aspen
Retail Automated Stock Replenishment™, Aspen Retail Resource Scheduling Optimization™, Aspen Richardson Rbooks™, Aspen
Richardson WinRace Database™, Aspen RTO Watch™, Aspen SCM™, Aspen SmartStep Advanced™, Aspen SmartStep™, Aspen
Specialty Products Automated Stock Replenishment™, Aspen Specialty Products Resource Scheduling Optimization™, Aspen Split™,
Aspen SULSIM®, Aspen Supply Chain Analytics™, Aspen Supply Chain Connect™, Aspen Supply Planner™, Aspen Tank
Management™, Aspen TASC™, Aspen Teams®, Aspen TICP™, Aspen Transition Manager™, Aspen Utilities™, Aspen Voice
Fulfillment Management™, Aspen Watch™, Aspen Water™, Aspen Web Fulfillment Management™, Aspen XPIMS™, Aspen Zyqad
Development™, Aspen Zyqad™, SLM™, SLM Commute™, SLM Config Wizard™, the Aspen leaf logo, and Plantelligence are
trademarks or registered trademarks of Aspen Technology, Inc., Cambridge, MA.
All other brand and product names are trademarks or registered trademarks of their respective companies.

This document is intended as a guide to using AspenTech's software. This documentation contains AspenTech
proprietary and confidential information and may not be disclosed, used, or copied without the prior consent of
AspenTech or as set forth in the applicable license agreement. Users are solely responsible for the proper use of
the software and the application of the results obtained.

Although AspenTech has tested the software and reviewed the documentation, the sole warranty for the software
may be found in the applicable license agreement between AspenTech and the user. ASPENTECH MAKES NO
WARRANTY OR REPRESENTATION, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THIS DOCUMENTATION,
ITS QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE.

Aspen Technology, Inc.


Ten Canal Park
Cambridge, MA 02141-2201
USA
Phone: (1) (617) 949-1000
Toll Free: (1) (888) 996-7001
Fax: (1) (617) 949-1030
URL: http://www.aspentech.com
Contents
1 Introduction .........................................................................................................1
About this document.........................................................................................1
Audience .........................................................................................................1
Related Documentation .....................................................................................1
Technical Support ............................................................................................1

2 Overview ..............................................................................................................3
Overview.........................................................................................................3
Data Requirements...........................................................................................4
Pipe Segment Data.................................................................................4
Relief Source Data..................................................................................5
System Design Constraints......................................................................6
Starting FLARENET ...........................................................................................7
Starting a New Model........................................................................................9
Saving the Model ........................................................................................... 11
Building the Pipe Network ............................................................................... 13
Defining the Scenarios .................................................................................... 22
Defining the Sources ...................................................................................... 26
Rating the Network ........................................................................................ 33
Printing Data and Results ................................................................................ 35

3 Developing the Model .........................................................................................36


Overview....................................................................................................... 36
Data Requirements......................................................................................... 36
Pipe Segment Data............................................................................... 37
Relief Source Data................................................................................ 38
System Design Constraints.................................................................... 40
Opening the Old Model.................................................................................... 40
Updating the Model ........................................................................................ 41
Defining the Scenarios .................................................................................... 47
Defining the Sources ...................................................................................... 49
Sizing the Network ............................................................................... 53
Design Calculations ........................................................................................ 55

iv Contents
1 Introduction

This section provides information on the following topics:


 About this Document
 Audience
 Related Documentation
 Technical Support

About this document


The guide provides step by step instructions to the most commonly used
features within FLARENET.

Audience
This guide is intended for process and process systems engineers.

Related Documentation
Title Content
FLARENET Reference Manual Reference Manual for Using FLARENET

Technical Support
AspenTech customers with a valid license and software maintenance
agreement can register to access the online AspenTech Support Center at:
http://support.aspentech.com
This Web support site allows you to:
 Access current product documentation
 Search for tech tips, solutions and frequently asked questions (FAQs)

1 Introduction 1
 Search for and download application examples
 Search for and download service packs and product updates
 Submit and track technical issues
 Send suggestions
 Report product defects
 Review lists of known deficiencies and defects
Registered users can also subscribe to our Technical Support e-Bulletins.
These e-Bulletins are used to alert users to important technical support
information such as:
 Technical advisories
 Product updates and releases
Customer support is also available by phone, fax, and email. The most up-to-
date contact information is available at the AspenTech Support Center at
http://support.aspentech.com.

2 1 Introduction
2 Overview

This section provides information on the following topics:


 Overview
 Data Requirements
 Starting FLARENET
 Starting a New Model
 Saving the Model
 Building the Pipe Network
 Defining the Scenario
 Defining the Sources

Overview
This Getting Started tutorial shows the fundamental principles involved in
using FLARENET to design and rate a new flare system. This "guided tour" will
expose you to most of the major features of FLARENET.
This tutorial assumes that you are familiar with the use of Windows and have
some prior experience in the design of flare systems.
This example consists of the following main parts:
1 Building The Pipe Network - Pipes and nodes will be added using either
the PFD or the Manager views.
2 Defining the Scenarios - Different scenarios will be set up to simulate
various process conditions.
3 Defining The Sources - Relieving sources will be added to each scenario.
4 Sizing the Network - Finally, the pipe network will be simulated and
results will be viewed both in textual and graphical form.

2 Overview 3
Data Requirements
Before you can start to build a computer model of the flare header system,
you must first define all the data that will determine your system.

Pipe Segment Data


Data Description
When you are
sizing a flare Connectivity You would normally have prepared a system sketch that
system, the initial defines the nodes to which the pipe segments are connected.
pipe diameters may Length and fittings These will be based upon either a preliminary or detailed
affect the solution loss coefficients for isometric drawing of the piping.
when there is a
each pipe segment
liquid phase and
the liquid knockout Diameter and pipe If you are rating an existing network, these will normally be
drum is modeled. schedule for each taken from the flare system P&ID. If you are sizing a new
You should initially pipe segment flare system, the pipe diameters that you define are relatively
size a network unimportant since they will be overwritten by the sizing
using vapor phase
algorithms. It is recommended that reasonable diameters be
methods.
defined, so that the sizing algorithm initializes to a condition
that will give faster convergence.

The following diagram shows the connectivity of the system that you will be
designing in this example.
Fig 1.1

4 2 Overview
The piping in the network diagram is detailed in the following table:

Item Length Internal Wall Fittings Elevation


(m) Diameter Thickness Loss Change
(mm) (mm) (m)
Flare Tip 3.0 0
Stack 100 876.3 19.05 0 100
Header 3 50 876.3 19.05 0 0
Tail Pipe 1 25 428.65 14.275 0 0
Tail Pipe 2 25 428.65 14.275 0 0

The flare tip is not a pipe segment, but rather a node that represents a zero
length piece of pipe with defined fittings loss coefficients. Since the internal
diameter is not specified it will assume the same diameter as the upstream
pipe segment. Fittings loss coefficients for the flare tip exclude pipe
enlargement and junction losses for the connect to the upstream pipe which
will automatically be calculated.

Relief Source Data


The following data must be specified for the sources:

Data Description
Flow and These may vary for each scenario that you are evaluating. If a
Composition relief source is not used in a particular scenario the flow may
be set to zero. The Flow refers to the quantity of fluid that the
source valve must pass as a consequence of the plant upset
condition. The Rated Flow refers to the quantity of fluid that
the source valve will pass due to its physical construction.
Rated flow must always be greater than or equal to flow.
Maximum Allowable This is the maximum pressure that can exist at the outlet of
Back Pressure the device (source) without affecting its capacity.
(MABP)
Downstream This temperature is used as the pressure independent
temperature temperature at which the source enters the network. This
temperature is used when ideal gas enthalpies are used to
calculate the heat balance, or as an initial guess when any
other enthalpy method is used.
Upstream pressure These are only used if Ideal Gas enthalpies are not used for
and temperature the heat balance. These may vary for each scenario that you
are evaluating. With relief valves, the flowing pressure should
be used.
Discharge flange This will normally be determined from the relief valve sizing
size calculations. If this value is unknown then the field should be
left empty to ignore the pressure change from the valve to
the downstream pipe due to the swage.

In this example, you will consider three scenarios that represent one fire case
and two single blocked discharge cases. The following tables define the source
data for each scenario.

2 Overview 5
Default Source Data

Source Flowrate Flange Mol. US DS US MABP


Name (kg/hr) Size Wt. Temp Temp Pres. (bar
(mm) (C) (C) (bar abs)
abs)
Source 100000 300 20 15 15 10 5.0
1
Source 100000 300 25 15 15 10 5.0
2

Source 1 is a control valve while Source 2 is a relief valve.

Source 1 Only Data

Source Flowrate Flange Mol. US DS US MABP


Name (kg/hr) Size Wt. Temp Temp Pres. (bar
(mm) (C) (C) (bar abs)
abs)
Source 100000 300 20 15 15 10 5.0
1
Source 0 300 25 15 15 10 5.0
2

Source 2 Only Data

Source Flowrate Flange Mol. US DS US MABP


Name (kg/hr) Size Wt. Temp Temp Pres. (bar
(mm) (C) (C) (bar abs)
abs)
Source 0 300 20 15 15 10 5.0
1
Source 100000 300 25 15 15 10 5.0
2

System Design Constraints


In this case, the following data is used for both Scenarios:
 Maximum allowable mach number - 0.50 for both main headers and
tailpipes.
 Maximum allowable noise – 100 dB for both main headers and tailpipes.

6 2 Overview
Starting FLARENET
The installation process creates a short-cut to FLARENET in the Start menu
under Programs...Hyprotech. To Start FLARENET,
1 Select the Start menu.
2 Select Programs-Hyprotech-FLARENET 3.51-FLARENET 3.51.
Fig 1.2

3 Now you are ready to begin working with FLARENET.


4 When you start FLARENET, the FLARENET Desktop will appear:

2 Overview 7
Fig 1.3

The view in Figure 1.3 has been resized; your Desktop view should appear
larger than this when initially opened. To re-size the view, click and drag
the outside border. To make the view full size, click the Maximise icon in
the upper right corner.
Before setting up the Getting Started case, you should choose the
FLARENET unit set for displaying information. You can check your current
unit set by accessing the Preferences Editor:
5 Select File-Preferences and the Preferences Editor view will open.
Fig 1.4

6 The current unit set is shown in the Units drop-down list. The FLARENET
default is Metric, which will be used for this example.

8 2 Overview
Fig 1.5

7 Confirm that the Edit Objects on Add checkbox is active (checked). This
option will open the object editor view each time a new object is added.
8 Click the OK button to close the Preferences Editor view.

Starting a New Model


To start a new case, do one of the following:
1 Select File-New on the main program menu bar.
2 Click the New Case icon.
The Description Editor view appears.
Fig 1.6

3 Enter the appropriate data (as shown in Figure 1.6) into the User Name,
Job Code, Project, and Description fields, and then click the OK button.
The Component Manager view then appears.

2 Overview 9
Fig 1.7

The Selected list is There are number of ways to select components for your simulation. One
empty, indicating that method is to filter the database for a certain component type. In this
no components have model, we will be using the following components: Methane, Ethane and
Propane.
yet been installed in
the case.
To add methane using the filter option:
1 Ensure that the HC checkbox in the Component Types group is
activated.
2 Start typing methane in the Selection Filter field. Notice that as you
are typing, the Database list will be filtered out to show only the
matching components.
3 Double click Methane in the Database list. Methane will now have
Initially, all the been selected and will be shown in the Selected list.
checkboxes in the
Component Types Fig 1.8
group are active.
You can deactivate
them by clicking
the Invert button.

10 2 Overview
4 Repeat the previous step with Ethane and Propane. As an alternative
Notice that now all
method, you may scroll through the Database list until you see the
the required
components are
desired component. Highlight the component by single clicking on it and
shown in the then click Add to place it in the Selected Components list.
Selected This Component Manager view will now appear as follows:
Components list,
indicating that they Fig 1.9
have been installed
in the case.

5 Click OK to close the Component Manager view and accept the list of
components.
6 Open the View menu and then the Data sub-menu. Select Components
from the sub-menu. The Components data view will be displayed:
Fig 1.10

You can use the


horizontal scroll
bar at the bottom
of the view to
view all of the
component
properties.

Saving the Model


It is good practice to periodically save your case by doing one of the
following:
 Click the Save icon on the toolbar.
 Select File-Save from the menu bar.
 Press Ctrl S.
As this is the first time you have saved your case, the Save FLARENET Model
view will be displayed:

2 Overview 11
Fig 1.11

After selecting an appropriate disk drive and directory in the Save in drop-
down menu, enter the name of the file to which you want to save the case in
the File name field.

Note: You do not need to include the .fnw extension; FLARENET will
add it automatically.
Click Save to close the view and save the file.

12 2 Overview
Building the Pipe Network
Since all scenarios have a common pipe network, you should first build the
pipe network model via the PFD.
Click the Open PFD View icon on the toolbar. The PFD view will be displayed
Before proceeding with its own toolbar.
any further, make
sure that the Edit
Fig 1.12
Objects on Add
checkbox on the
General tab of the
Preferences Editor
view is checked.

At this point the view should be blank, since we have not added a single
object yet.
The desired objects can be added by using either of the following methods:
 Clicking the Toggle Palette Display icon on the PFD view or pressing the
F4 key will open the Toolbox view, which displays all the objects available
in FLARENET. You can add an object by clicking on it
Fig 1.13

2 Overview 13
 Objects can also be added via the Pipe Manager and the Node Manager
views. These are accessible through Pipes... and Nodes... in the Build
menu, respectively.
For the Flare Tip, click the Flare Tip icon on the Toolbox view. Since the Edit
Objects on Add checkbox is selected, The Flare Tip Editor view will be
displayed:
Fig 1.14

By default the Flare Tip has been named as 1, which can be changed to a
more appropriate name as follows:
1 Click in the Name field on the Flare Tip Editor view.
The fittings loss 2 Delete the default name and type Flare Tip as the new name.
coefficient basis Since this example is of smaller size, the Location field will be left blank.
should be set to This field is only useful for larger cases with multiple sections (areas)
Total Pressure to
within a same plant. Now you need to specify the pipe, which will be
indicate that the
loss coefficient simulated as a flare stack, and it is attached to the Tip.
we are defining 3 Enter the name Stack in the Inlet field.
will calculate the 4 In the At drop-down list, select Downstream as the pipe end connected
pressure loss in
to the Tip.
the flare tip
including the In order to complete the Flare Tip Editor view, you need to specify the
velocity pressure Diameter and the Fitting Loss values on the Calculations tab.
loss.
5 On the Calculations tab, enter 876.3 as the diameter and 3 as the fitting
loss in the appropriate fields.

14 2 Overview
Fig 1.15

The default
Now you have provided all the necessary information about the Tip.
methods, as
defined in the 6 Click OK to close the view.
Calculation Options
Notice that two new objects have been added to the PFD view. These may
Editor view, should
be Isothermal
be drawn one on top of the other so you should either manually arrange
Vapor Pressure them by clicking and dragging the object icons or let FLARENET auto-
Drop, and arrange the icons by selecting View-PFD-Regenerate.
Compressible Gas 7 Open the Stack property view and move to the Dimensions tab.
VLE.
8 Specify the Length as 100 m and the Elevation Change as 100 m.
This will result in a vertical pipe measuring 100 m tall.
9 Select the Nominal Diameter as 36 inch and the Pipe Schedule as 40.

2 Overview 15
Fig 1.16

10 On the Methods tab, confirm that Vertical Pipe and VLE Method are set
as default models.
In this example, every pipe segment uses the default models which are
specified on the Methods tab of the Calculation Options Editor view.
11 Click OK to close the Stack property view.
Now you need to add another pipe segment which will be added using the
Pipe Manager view.
12 Select Build-Pipes from the menu bar. The Pipe Manager view will be
displayed.
Fig 1.17

13 Click the Add button.


The Pipe Editor property view will be displayed.

16 2 Overview
Fig 1.18

14 Change the default name to Header 3.


15 Move to the Dimensions tab and enter the following data in the
appropriate fields:
Field Value
Length (m) 50
Nominal Diameter (inch) 36
Pipe Schedule 40

16 Click OK to close the Pipe Editor view.


17 Close the Pipe Manager view by clicking the OK button.
You need to attach Header 3 with Stack using a node. FLARENET allows
you to choose between a variety of nodes, since you need a simple
connection between the two pipes, a Connector node will be used.
18 On the PFD Toolbox view click on the Connector icon.

This will open the Connector Editor view.

2 Overview 17
Fig 1.19

19 On the Connections tab, enter the new name as Con 1.


20 In the Downstream drop-down list, select Stack and specify the
connection at Upstream (of Stack) in the At drop-down list.
21 In the Upstream drop-down list, select Header 3 and specify the
connection at Downstream (of Header 3) in the At drop-down list.
22 Move to the Calculations tab.
Fig 1.20

Notice that by default the Theta has a value of 90 deg and the Fitting Loss
Method is set as Calculated. These and the other entries may be left at
their default values for this example.
23 Click the OK button to close the Connector Editor view.
Now, a tee will be added, using the Node Manager, to combine the flow
from the two sources.
24 Select Build-Nodes. The Node Manager view will be displayed.

18 2 Overview
Fig 1.21

25 Click the Add button and Select Tee from the pop up list.
The Tee Editor will be displayed.
Fig 1.22

26 Change the default name to Tee 1 in the Name field.


27 Specify the Downstream connection to be Header 3 and select
Upstream from the At drop-down list.
28 Move to the Calculations tab and change the Fittings Loss Methods
setting to Miller in the drop-down list. The remaining fields may be left at
their default values.
29 Close the Tee Editor property view by clicking the OK button.
30 Click OK to close the Node Manager view.
Now, you can add two pipe segments to the upstream and branch section of
Tee 1 using the Pipe Manager view.
31 Open the Pipe Manager view by selecting Build-Pipes.

2 Overview 19
Fig 1.23

32 Click the Add button to add a new pipe segment.


33 Change the default pipe name to Tail Pipe 1.
34 Specify Tee 1 as the Downstream connection and select Branch in the
At drop-down list

Note: Setting the tailpipe option to Yes will cause the pressure
drop to be calculated using the rated flows rather than the
actual flow. For this pipe which is a tail pipe to a control valve
source, the rated flow and actual flow will be the same so the
setting of this option will have no effect.

20 2 Overview
Fig 1.24

35 Move to the Dimensions tab and specify the Length as 25 m.


36 Set Nominal Diameter as 18 inch from the drop-down list.
37 Click Next to add another pipe segment.
Notice that Tail Pipe 1 has been added to the Pipe Manager list.
38 Change the new pipe segment default name to Tail Pipe 2.
39 Specify Tee 1 as the Downstream connection and select Upstream in
the At drop-down list. Since this pipe is a tail pipe for a relief valve set
the Tailpipe option to Yes.
40 Move to the Dimensions tab and specify the Length as 25 m.
41 Set Nominal Diameter as 18 inch from the drop-down list
Fig 1.25

42 Click the OK button to close the Pipe Editor property view.

2 Overview 21
43 Close the Pipe Manager view by clicking the OK button.

You can also open Select Data-Pipes from the View menu on the menu bar. The Pipes view
the Pipes view by displays the data for all of the pipe segments:
clicking the Open
Fig 1.26
Pipe Tabular View
icon.

You could also check the PFD to ensure that the proper connections have
been made. A portion of the PFD is displayed below:
Fig 1.27

Defining the Scenarios


You now need to define the data for the entire scenario, the Default
Scenario, Source 1 Only and Source 2 Only scenarios. Since each case
must contain at least one scenario, a set of default scenario data is created
when you start a new case. We need to modify this data.
1 Select Scenarios from the Build menu on the menu bar.
The Scenario Manager view will be displayed.

22 2 Overview
Fig 1.28

2 Double click Default Scenario in the Scenario list.


Fig 1.29

3 The Scenario Editor view will be displayed. Alternatively, you could select
Default Scenario in the Scenario list then click Edit.
Update the header Mach number limit on the Constraints page for the
4 Default Scenario scenario as shown in Figure 1.30, then click OK to
close the Edit Scenario view and return to the Scenario Manager.

2 Overview 23
Fig 1.30

Now we should add the data for the Source 1 Only scenario.
4 Click Add on the Scenario Manager. The Clone Scenario From view will
be displayed.
Fig 1.31

5 Select the only entry in the view, i.e. Default Scenario scenario.
6 Change the default name to Source 1 Only and enter the data for the
Source 1 Only scenario as shown in Figure 1.32.

24 2 Overview
Fig 1.32

7 To add a new scenario click Next on the Scenario Editor and select the
Source 1 Only scenario from the Clone Scenario From view.
8 Change the default name for the new scenario to Source 2 Only.
Fig 1.33

9 Enter the data for the new scenario as shown in Figure 1.34.

2 Overview 25
Fig 1.34

10 Click OK to close the Scenario Editor view and return to the Scenario
Manager, then click OK to close the Scenario Manager.

Defining the Sources


You will now enter the source data for the sources in all scenarios. Since for
the first part of the example you will be defining the source compositions in
terms of molecular weight, the program preferences must be set to accept
the compositions on this basis.
1 Select Preferences from the File menu on the menu bar. The
Preferences view will be displayed.
Fig 1.35

26 2 Overview
Ensure that Mol. Wt. is selected in the Composition Basis drop-down
list on the Defaults tab.
Fig 1.36

2 Click OK to close the Preferences Editor view.


Before defining a set of source data, you must select the scenario which
corresponds to this data. You will start by defining the data for the Default
Scenario.
3 Select the Default Scenario scenario from the drop-down list on the
main Tool Bar. Any open data views would now display data for this
scenario. This can be done using the scenario selector drop-down list on
the main FLARENET toolbar.

2 Overview 27
Fig 1.37

You can now add the data corresponding to this scenario for each source.
4 Select Nodes from the Build menu on the main menu bar (ALT B N). The
Node Manager view will be displayed:
Fig 1.38

5 Click Add and select Control Valve from the pop up list.

28 2 Overview
Fig 1.39

The Control Valve Editor view will be displayed:


Fig 1.40

6 Change the default name to Source 1. Select Tail Pipe 1 in the Outlet
drop-down list and set connection to be at Upstream (of Tail Pipe 1).

2 Overview 29
Fig 1.41

7 Move to the Conditions tab and set the Mass Flow as 100000 kg/hr. In
this example, the inlet pressure and temperatures are the same as the
default values but this will not normally be the case.
Fig 1.42

The Mole Fractions


are automatically
estimated from the
Molecular Weight.
Because HC is
selected from the
drop-down list, only
hydrocarbon
components will be
used to match the
Molecular Weight.

8 On the Composition tab, specify the Mol. Wt. to be 20. Once you have
entered the Mol. Wt. and tabbed to the next field you will notice the
composition will be calculated to give the required Mol. Wt.

30 2 Overview
Fig 1.43

9 Click Next to add a new source. The node pop up list will again be
displayed.
10 Select Relief Valve from the pop up menu and the Relief Valve view will
be displayed.
11 Name the new source as Source 2 on the Connections tab.
12 Select Tail Pipe 2 in the Outlet drop-down list and set connection to be
at Upstream (of Tail Pipe 2).
Fig 1.44

13 On the Conditions tab, check that the relief valve set pressure or MAWP
is set to the default value of 10 bar which is correct for this source. Select
the Auto checkbox next to the Relieving pressure field. This tells
FLARENET to calculate the relieving pressure from the MAWP and the
selected Contingency, which should be left as Operating in this case.
Check that the relieving pressure is calculated as 10.89 bar.
14 Still on the Conditions tab, check that the MABP is set to 5.0 bar. Then
enter the required mass flow rate for this source of 100000 kg/ hr. Select
the Auto checkbox next to the Rated flow field. This tells FLARENET to

2 Overview 31
calculate the rated flow for the valve from the specified fluid conditions
and properties, valve type and orifice area.
15 Still on the Conditions tab, use the drop-down list next to the Orifice
area field to select orifice code T. Check that the orifice area is updated to
16774 mm2 and notice the rated flow calculation is updated to reflect the
increased orifice area.
16 On the Composition tab specify the molecular weight of the fluid to be
25. When you tab away from this field, FLARENET will calculate the
composition of the fluid from the mole weight. Click back on the
Conditions tab to confirm that the Rated flow calculation has been
updated to give a rated flow of 109,405 kg/hr.
Fig 1.45

17 Click OK to close the Relief Valve Editor view.


The Node Manager view will now appear as follows:
Fig 1.46

18 Close the Node Manager view by clicking the OK button.


19 Select Data-Sources from the View menu on the menu bar.
The Sources data view for the Default Scenario will be displayed:

32 2 Overview
Fig 1.47

You must now add the source data for the other two scenarios.
20 Select the Source 1 Only scenario from the Scenario Selector drop-
down list on the toolbar (to the right of the icons). Any open data views
will now display data for this scenario.
21 Make the following changes to the flowrates in the Source 1 Only
Scenario (all other information remains the same):
Source 1 - 100000 kg/hr
Source 2 - 0 kg/hr
Finally reselect the Default Scenario from the Scenario Selector.
22 Next, select the Source 2 Only scenario from the Scenario Selector
drop-down list on the tool bar (to the right of the icons) and make the
following changes to the Source 2 Only:
Source 1 - 0 kg/hr
Source 2 - 100000 kg/hr
Finally reselect the Default Scenario from the Scenario Selector.

Rating the Network


We have now entered all the model data and can now make the sizing
calculations. We will need to set the calculation options before starting the
calculations.
1 Select Options from the Calculation menu on the menu bar. The
Calculation Options Editor view will be displayed:

2 Overview 33
Fig 1.48

2 For this example we are going to use the default methods and settings
defined when FLARENET creates a new model. This includes the following
key options:
On the General tab, Calculation Mode should be set to Rating, Enable
heat Transfer checkbox should be cleared, Include Kinetic Energy
checkbox should be cleared.
On the Scenarios tab, Calculate should be set to All Scenarios.
On the Methods tab, the VLE Method should be set to Compressible
Gas, the Enthalpy Method to Ideal Gas and all pressure drop methods
to Isothermal Gas.
You can now start the calculations.
3 Select Calculate from the Calculation menu on the menu bar (ALT C C or
CTRL R). Alternatively, you could click the Calculate icon.

Fig 1.49

Once the calculations are complete you can review the results.
4 Select Results-Messages from the View menu on the menu bar.
The Messages data view will be displayed.

34 2 Overview
Fig 1.50
The Problems tab
lists two mach
number violations.
These problems can
be fixed by doing
design calculations
for the network but
for this example we
will ignore the
problem.
The above view contains general information and warning messages
regarding the calculations.
5 Select Source 1 Only from the Scenario selector.
6 Click Pressure/Flow Summary icon on the toolbar.
The Pressure/Flow Summary view will be displayed:
Fig 1.51

With the Pressure/Flow Summary view open, select each scenario in turn
using the Scenario selector on the toolbar.

Note: In the scenario Source 1 Only, the mach number problem


on Tail Pipe 1 is automatically highlighted.
7 At this point save the model using either the Save icon from the main
Toolbar or the File-Save menu option.

Printing Data and Results


To print data and results:
1 Select File-Print from the menu bar. The Print view will be displayed.
2 Click on the appropriate checkboxes to select the items that you want to
print. Also check the All Scenarios checkbox to print the results for all of
the scenarios instead of just the current scenario. If you want to print to a
file, check the Print To Text File checkbox, then select the file type from
the Text File Type drop-down list.
3 Click OK.

2 Overview 35
3 Developing the Model

This section provides information on the following topics:


 Overview
 Data Requirements
 Opening the Old Model
 Updating the Model
 Defining the Scenarios
 Defining the Sources
 Design Calculations

Overview
In this Getting Started tutorial you will change the network designed in
Getting Started to model the tie-in of two new control valves into our current
system. The modified system will be simulated for two new scenarios, one
each for the new sources.
This tutorial assumes that you are familiar with the use of Windows and have
This tutorial is a some prior experience in the design of flare systems.
continuation of the
one in Getting This example consists of the following main parts:
Started and 1 Building The Pipe Network - Pipes and nodes will be added using either
requires that you the PFD or the Manager views.
complete that
tutorial before 2 Defining the Scenarios - Different scenarios will be set up to simulate
continuing with this various process conditions.
one. 3 Defining The Sources - Relieving sources will be added to each scenario.
4 Sizing the Network - Finally, the pipe network will be simulated and
results will be viewed both in textual and graphical form.

Data Requirements
Before you can start to upgrade a computer model of the existing flare header
system, you must first define all the data that will determine your system.

36 3 Developing the Model


Pipe Segment Data
When you are Data Description
sizing a flare Connectivity You would normally have prepared a system sketch
system, the initial that defines the nodes to which the new pipe
pipe diameters may segments are connected.
affect the solution
when there is a Length and fittings loss These will be based upon either a preliminary or
liquid phase and coefficients for new pipe detailed isometric drawing of the piping.
the liquid knockout segment
drum is modelled. Diameter and pipe schedule If you are rating an existing network, these will
You should initially for each pipe segment normally be taken from the flare system P&ID. If
size a network you are sizing a new flare system, the pipe
using vapour phase diameters that you define are relatively
methods. unimportant since they will be overwritten by the
sizing algorithms. It is recommended that
reasonable diameters be defined, so that the sizing
algorithm initialises to a condition that will give
faster convergence.

The following diagram shows the connectivity of the system which includes
the new sources you will be adding in this example.
Fig 2.1

The pipe segments in the network diagram are detailed in the following table.

Segment Length (m) Nominal Schedule Fittings Elevation


Name Diameter (inch) Loss Change (m)
Stack 100 36 40 0 100
Header 1 50 28 30 0 0
Header 2 50 28 30 0 0
Header 3 50 36 40 0 0
Tail Pipe 25 18 40 0 0
1
Tail Pipe 25 18 40 0 0
2

3 Developing the Model 37


Tail Pipe 25 12 40 0 0
3
Tail Pipe 25 18 40 0 0
4

The new pipe segments Header 1, Header 2, Tail Pipe 3 and Tail Pipe 4 will be
added.

Relief Source Data


The following data must be specified for the sources:

Data Description
Flow and These may vary for each scenario that you are evaluating.
Composition If a relief source is not used in a particular scenario the flow
may be set to zero. The Flow refers to the quantity of fluid
that the source valve must pass as a consequence of the
plant upset condition. The Rated Flow refers to the quantity
of fluid that the source valve will pass due to its physical
construction. Rated flow must always be greater than or
equal to flow.
Maximum Allowable This is the maximum pressure that can exist at the outlet of
Back Pressure the device (source) without affecting its capacity.
(MABP)
Downstream This temperature is used as the pressure independent
Temperature temperature at which the source enters the network. This
temperature is used when ideal gas enthalpies are used to
calculate the heat balance, or as an initial guess when any
other enthalpy method is used.
Upstream Pressure These are only used if the Ideal Gas enthalpies are not used
and Temperature for the heat balance. These may vary for each scenario that
you are evaluating. With relief valves, the flowing pressure
should be used.
Discharge Flange This will normally be determined from the relief valve sizing
Size calculations.

In this example, you will consider five scenarios that represent one fire case
and four single blocked discharge cases. The following tables define the
source data for each scenario.
The discharge flange size values are left undefined. In this case they are
assumed to have the same diameter as the attached pipes

Default Source Data

Source Flowrate Mol. US Temp DS US MABP


Name (kg/hr) Wt. (C) Temp Pres. (bar
(C) (bar abs)
abs)

38 3 Developing the Model


Source 100000 20 15 15 10 5.0
1
Source 100000 25 15 15 10 5.0
2
Source 100000 30 15 15 10 5.0
3
Source 100000 35 15 15 10 5.0
4

Source 1 Only Data

Source Flowrate Mol. US DS US MABP


Name (kg/hr) Wt. Temp Temp Pres. (bar
(C) (C) (bar abs)
abs)
Source 100000 20 15 15 10 5.0
1
Source 0 25 15 15 10 5.0
2
Source 0 30 15 15 10 5.0
3
Source 0 35 15 15 10 5.0
4

Source 2 Only Data

Source Flowrate Mol. US DS US MABP


Name (kg/hr) Wt. Temp Temp Pres. (bar
(C) (C) (bar abs)
abs)
Source 0 20 15 15 10 5.0
1
Source 100000 25 15 15 10 5.0
2
Source 0 30 15 15 10 5.0
3
Source 0 35 15 15 10 5.0
4

Source 3 Only Data

Source Flowrate Mol. US DS US MABP


Name (kg/hr) Wt. Temp Temp Pres. (bar
(C) (C) (bar abs)
abs)
Source 0 20 15 15 10 5.0
1
Source 0 25 15 15 10 5.0
2
Source 100000 30 15 15 10 5.0

3 Developing the Model 39


3
Source 0 35 15 15 10 5.0
4

Source 4 Only Data

Source Flowrate Mol. US DS US MABP


Name (kg/hr) Wt. Temp Temp Pres. (bar
(C) (C) (bar abs)
abs)
Source 0 20 15 15 10 5.0
1
Source 0 25 15 15 10 5.0
2
Source 0 30 15 15 10 5.0
3
Source 100000 35 15 15 10 5.0
4

System Design Constraints


In this case, the following data is used for all Scenarios:
 Maximum allowable mach number - 0.50 for both main headers and
tailpipes.
 Maximum Noise – 100 dB for both main headers and tailpipes.

Opening the Old Model


1 Start FLARENET and open the previously stored case that you have just
saved in Getting Started.
2 Select Open from the File menu on the main program menu bar.
3 Click the Load An Existing Model From Disk button.
4 Press Ctrl O.
5 The Open FLARENET Model view will appear.
Fig 2.2

40 3 Developing the Model


6 Use the Look in drop-down menu to select the appropriate disk drive and
directory.
7 Next select the file that you created in Getting Started from the list and
click the Open button.

Updating the Model


You need to add new pipe segments to the existing model, but first you must
delete the connection between Tee 1 and Header 3. Open the PFD and delete
the connection as follows:
1 Click the Toggle Connect/Arrange Mode icon to switch to connect
mode and select the connection between Tee 1 and Header 3.
Fig 2.3

2 Press the DELETE key.


To add a tee section after Header 3:
3 Open the Node Manager view, using the Build-Nodes menu option.
Fig 2.4

3 Developing the Model 41


Click the Add button and select the Tee from the pop up list.
The Tee Editor view will be displayed:

42 3 Developing the Model


Fig 2.5

5 Specify the name to be Tee 3, the Downstream connection to be


Since this example Header 3 and select Upstream from the At drop-down list.
is of smaller size, 6 Move to the Calculations tab and change the Fittings Loss Methods
therefore the
setting to Miller in the drop-down list.
Location field will
be left blank. This 7 Close the Tee Editor property view by clicking OK button.
field is only useful 8 Click OK to close the Node Manager view.
for larger case with
multiple sections Now, you can add two pipe segments to the upstream and branch section
(areas) within a of Tee 3 using the Pipe Manager view.
same plant. 9 Open the Pipe Manager view by selecting Pipes from the Build
menu.
Fig 2.6

10 Click the Add button to add a new pipe segment.


11 Change the default pipe name to Tail Pipe 4.

3 Developing the Model 43


12 Specify Tee 3 as the Downstream connection and select Branch in
After clicking Next, the At drop-down list.
you will notice that
Tail Pipe 4 has Fig 2.7
been added to the
Pipe Manager list.

13 Move to the Dimensions tab and specify the Length as 25 m.


14 Set Nominal Diameter as 18 inch from the drop-down list.
15 Click Next to add another pipe segment.
16 Change the new pipe segment default name to Header 2.
17 Specify Tee 3 as the Downstream connection and select Upstream in
the At drop-down list.
18 Move to the Dimensions tab and specify the Length as 50 m.
19 Set Nominal Diameter as 28 inch from the drop-down list.
Fig 2.8

20 Click the OK button to close the Pipe Editor property view.


21 Close the Pipe Manager view by clicking the OK button.

44 3 Developing the Model


Notice that three new objects have been added to the PFD view. You can
either manually arrange them by clicking and dragging the object icons or
let FLARENET do the auto-arrangement by selecting PFD-Regenerate
from the View menu.
Now you will add a tee section using the PFD Toolbox.
22 Open the PFD Toolbox view (if it is not displayed) by clicking the PFD
Toolbox icon
23 Click the Tee icon on the Toolbox view.
Since the Edit Objects on Add checkbox is selected, The Tee Editor view
will be displayed.
Fig 2.9

24 Change the default name to Tee 2.


25 Specify Header 2 as the Downstream connection and select Upstream
in the At drop-down list. On the Calculations tab set the fittings loss
method to Miller.
26 Close the Tee Editor view by clicking the OK button.
Multiple pipe
buttons with Now, you can add two pipe segments to the upstream and branch section
different of Tee 2 using the PFD Toolbox view.
orientations will 27 Click the Pipe button to add a new pipe segment. A fly out menu of 4
appear when this is buttons showing alternate pipe directions will appear to allow you to select
selected.
the orientation that you require for your PFD. This is only the initial
orientation and it may be changed later.
28 On the Pipe Editor view, change the default pipe name to Tail Pipe 3.
29 Specify Tee 2 as the Downstream connection and select Branch in the
At drop-down list.

3 Developing the Model 45


Fig 2.10

30 Move to the Dimensions tab and specify the Length as 25 m.


31 Set Nominal Diameter as 12 inch from the drop-down list.
32 Close the Pipe Editor property view by clicking the OK button.
33 Click the Pipe button again to add another pipe segment.
34 Change the new pipe segment default name to Header 1.
35 Specify Tee 2 as the Downstream connection and select Upstream in
the At drop-down list.
36 Specify Tee 1 as the Upstream connection and select Downstream in
the At drop-down list.
37 Move to the Dimensions tab and specify the Length as 50 m.
38 Set Nominal Diameter as 28 inch from the drop-down list.
Fig 2.11

46 3 Developing the Model


39 Click the OK button to close the Pipe Editor property view.
Select Data-Pipes from the View menu on the menu bar. The Pipes view
displays the data for all of the pipe segments:
Fig 2.12

At this point you might want to rearrange the new items on the PFD
manually or use the View-PFD-Regenerate menu option to redraw the
PFD automatically. The PFD should be similar to that displayed in Figure
2.13:
Fig 2.13

Defining the Scenarios


You now need to define the data for the new scenarios, the Source 3 Only
and Source 4 Only scenarios. The existing model already contains three
scenarios which you will still be using in this example. To add the new
scenarios:
1 Select Scenario from the Build menu on the menu bar.
The Scenario Manager view will be displayed.

3 Developing the Model 47


Fig 2.14

2 Click Add on the Scenario Manager. The Clone Scenario From view will
be displayed.
Fig 2.15

3 Select the Source 2 Only scenario from the list.


4 Change the default name to Source 3 Only and set the Mach number
data in the Headers and Tailpipes tab to 0.5 as shown in Figure 2.16.

48 3 Developing the Model


Fig 2.16

5 To add a new scenario click Next on the Scenario Editor and select the
Source 3 Only scenario from the Clone Scenario From view.
6 Change the default name for the new scenario to Source 4 Only.
Fig 2.17

7 Enter the data for the new scenario as shown in Figure 2.16.
8 Click OK to close the Scenario Editor view and return to the Scenario
Manager. Now select Default Scenario and click the Current button to
make this the working scenario. Click OK to close the Scenario Manager.

Defining the Sources


You will now enter the source data for the sources in all scenarios. Since for
the first part of the example you will be defining the source compositions in
terms of molecular weight, the program preferences must be set to accept
the compositions on this basis as described in Getting Started.
1 Select Nodes from the Build menu on the main menu bar (Alt B S).

3 Developing the Model 49


The Node Manager view will be displayed:
Fig 2.18

2 Click Add and select Control Valve from the pop up list.
Fig 2.19

The Control Valve Editor view will be displayed:


Fig 2.20

3 Change the default name to Source 3. Select Tail Pipe 3 in the Outlet
drop-down list and set connection to be at Upstream (of Tail Pipe 3).

50 3 Developing the Model


4 Move to the Conditions tab and set the Mass Flow as 100000 kg/hr.
Fig 2.21

5 On the Composition tab, specify the Mol. Wt. to be 30.

Note: The composition will be calculated as soon as you tab away


from the Mol Wt field.
Fig 2.22

The Mole Fractions


are automatically
estimated from the
Molecular Weight.
Because HC is
selected from the
drop-down list, only
hydrocarbon
components will be
used to match the
Molecular Weight.

6 Click Next to add a new source. The node pop up list will again be
displayed.
7 Again select Control Valve and the Control Valve Editor view will be
displayed.
8 Name the new source as Source 4.
9 Select Tail Pipe 4 in the Outlet drop-down list and set connection to be
at Upstream (of Tail Pipe 4).

3 Developing the Model 51


Fig 2.23

10 Repeat 5-7 to add all the information required by the scenario. Specify
Mole Wt. to be 35 on the Composition tab.
11 Click the OK button to close the Control Valve Editor view.
The Node Manager view will now appear as follows:
Fig 2.24

12 Close the Node Manager view by clicking the OK button.


13 Select Data-Sources from the View menu on the menu bar.
The Sources data view for the Default Scenario will be displayed:
Fig 2.25

14 You must now add the source data for the other four scenarios.

52 3 Developing the Model


15 Select the scenarios from the selector on the tool bar. Any open data
views will display data for the selected scenario.
Make the following changes to the flowrates in all scenarios:

Scenarios Source 1 Source 2 Source 3 Source 4


(kg/hr) (kg/hr) (kg/hr) (kg/hr)
Source 1 100000 0 0 0
Only
Source 2 0 100000 0 0
Only
Source 3 0 0 100000 0
Only
Source 4 0 0 0 100000
Only

For each scenario, ensure that the sources which have a flowrate of zero are
ignored (i.e. select the Ignore checkbox for the source).

Sizing the Network


You have now entered all the model data and can now make the sizing
calculations. You will need to set the calculation options before starting the
calculations.
1 Select Options from the Calculation menu on the menu bar. The
Calculation Options Editor view will be displayed:
Fig 2.26

3 Developing the Model 53


2 For the first calculation of this example ensure that the following options
are set:
 On the General tab, Calculation Mode should be set to Rating, Enable Heat
Transfer checkbox should be cleared, Include Kinetic Energy checkbox
should be cleared, Ignore Source to Pipe Pressure Loss in Design Mode
should be set.
 On the Scenarios tab, the Calculate drop-down list should be set to
Current Scenario.
 On the Methods tab, the VLE Method should be set to Compressible Gas,
the Enthalpy Method to Ideal Gas and all the pressure drop methods to
Isothermal Gas.
3 Ensure that the Default Scenario is selected using the Scenario
Selector drop-down list on the main toolbar.
You can now start the calculations.
4 Select Calculate from the Calculation menu on the menu bar (ALT C C or
ctrl r). Alternatively, you could click the Calculations icon.
Fig 2.27

Once the calculations are complete you can review the results.
5 Select Results-Problems from the View menu on the menu bar. The
Messages data view will be displayed.
Fig 2.28

The above view contains general information and warning messages


regarding the calculations. In this case the mach number exceeds the design
value of 0.5, which was defined for each scenario, for Tail Pipe 3. It also
shows both upstream and downstream pipe segment mach number for each
violation. It is due to smaller pipe segments causing very high fluid velocities
across the pipe segment.
At this point, it is a good idea to save your case before doing detail design.
6 Select Save As from the File menu and save the file as Get Started 2
Rating.fnw.

54 3 Developing the Model


Design Calculations
1 We will now use FLARENET's design capabilities to redesign the network to
resolve the mach number problem we have identified in the rating
calculation we have just completed.
Use the Calculation Mode selector on the main toolbar to change the
calculation mode to Debottleneck. This calculation mode will redesign
the flare system to meet our defined system limits without reducing the
current sizes of any pipes.
2 Click the Start Calculation icon on the toolbar.
After the calculation has been completed, you can review the new results.
Fig 2.29

3 Open the Results - Messages view from the View menu and then select
the Sizing tab to see a list of the changes that FLARENET has made to the
network. In this case it has increased the size of Tailpipe 3 from 12 inch
to 14 inch.
You can also access 4 Select Results - Pressure/Flow Summary from the View menu on
the Pressure/Flow
the menu bar.
Summary view by
clicking the Open The Pressure/Flow Summary view will be displayed:
Pressure/Flow
Summary icon. Fig 2.30

Notice that the upstream and downstream mach numbers are now within
the design specification for the given scenario. You can use the bottom
scroll bar to move across the columns.
We now have a flare system that is designed correctly for the Default
Scenario where all sources are relieving but we have not yet checked
that it is adequate for all of the scenarios. To do this we will do a Rating
calculation for all of the scenarios.
5 Open the Calculation Options view and set the Calculation Mode to
Rating on the General tab. On the Scenarios tab, set the Calculate
option to All Scenarios. After closing the Calculation Options view,
click the Start Calculation icon to run the rating check.

3 Developing the Model 55


6 When the calculations have finished, open the Results - Messages view
from the View menu. Click on the Problems tab where any violations of
our system design limits will be displayed. You will see that FLARENET
has detected a violation of the mach number limits for the tail pipes in the
single source scenarios.
Fig 2.31

The reason for this is that the lower back pressure in the system when only a
single source is relieving means that the gas density is reduced resulting in
higher velocities.
7 To fix this problem with our design we will re-run the Debottleneck
calculations for all the scenarios. Use the Calculation Mode selector on
the main toolbar to change the calculation mode to Debottleneck and
then click the Calculate icon.
8 When complete, review the Problems tab of the Messages view to
confirm that the flare system now meets all our design limits in all
scenarios. The Sizing tab will show which pipe sizes have been
increased.
Fig 2.32

Note: We could have run the Debottleneck calculations for all


scenarios immediately after our first rating calculation and
obtained the same results. While this might have been faster, we
have obtained a better understanding of which scenarios have
caused changes to pipe sizes by doing our calculations in stages.
9 Select Results-Pressure/Flow Summary from the View menu on the
menu bar.
The Pressure/Flow Summary view will be displayed:
Fig 2.33

56 3 Developing the Model


Notice that the upstream and downstream mach numbers are now within the
design specification for the given scenario. You can use the bottom scroll bar
to move across the columns.
10 Press Ctrl A to save the case as a new file.
11 Enter the new file name as Get Started 2 Design.fnw on the Save
FLARENET Model view and click the Save button.