Sunteți pe pagina 1din 6

Mantri Magnolia - progress as on 27.

07
Planned work completion till 30.07.11 ( in % ) Phase 1
I 1 2 4 5 6 7 8 9 II 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 III 1

Sl.No

Description

Guest Floors Fourth Floor False ceiling Fixing of door frame Dadoing:For toilets/ Kitchen/lift cladding Fixing of Vanity counters Fixing of Marbles in dado/niche above counter Fixing of inbuilt furniture / wall panel / mirror panel Flooring - Tiles/ Marble threshold,IPS for corridors Internal Painting works excluding final coat Fifth Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing & brick bat filling in toilet area Fixing of plumbing line & sprinkler line including testing Fixing of HVAC & Ducting Fixing of FCUs POP punning in rooms & corridors False ceiling Fixing of door frame dadoing:For toilets/ Kitchen/lift cladding Fixing of Vanity counters Fixing of Marbles in dado/niche above counter Fixing of inbuilt furniture / wall panel / mirror panel Flooring - Tiles/ Marble threshold,IPS for corridors Sixth Floor Marking for levels, bullmark for MEP & ID works 100% 100% 100% 100% 100% 65% 41% 33% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 83% 100% 100% 100% 100% 16% 41% 100%

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 IV 1 2 3 4 5 6 7 8 9 10 11 12 14 15 V 1 2 3 4 5 6 7 8 9 10

Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing &brick bat filling in toilet area Fixing of plumbing line & sprinkler line including testing Fixing of HVAC & Ducting Fixing of FCUs POP punning in rooms & corridors False ceiling Fixing of door frame dadoing:For toilets/ Kitchen/lift cladding Fixing of Vanity counters Second Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing &brick bat filling in toilet area Fixing of plumbing line & sprinkler line including testing Fixing of HVAC & Ducting Fixing of FCUs POP punning in rooms & corridors Fixing of door frame dadoing:For toilets/ Kitchen/lift cladding Third Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing &brick bat filling in toilet area Fixing of plumbing line & sprinkler line including testing Fixing of HVAC & Ducting Guest Floors Seventh Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works

100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 83% 11% 74% 45% 16% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 42% 13% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% Phase II

I 1 2

100% 100%

3 4 5 6 7 8 9 10 12 14 II 1 2 3 4 5 6 7 8 11 III 1 2 3 4 5 6 IV 1 VI 1

Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing &brick bat filling in toilet area Fixing of plumbing line & sprinkler line including testing Fixing of HVAC & Ducting POP punning in rooms & corridors Fixing of door frame Eighth Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines bore packing Waterproofing &brick bat filling in toilet area POP punning in rooms & corridors Ninth Floor Marking for levels, bullmark for MEP & ID works Corecutting for plumbing works Chasing for electrical conduits Chasing for plumbing works Fixing of electrical conduits/boxes walls & above false ceiling Fixing of sanitary lines Tenth Floor Marking for levels, bullmark for MEP & ID works Eleventh Floor Public Area Balance Civil works

100% 100% 100% 100% 100% 100% 22% 22% 100% 9% 100% 100% 100% 100% 100% 100% 67% 30% 63% 100% 100% 100% 100% 22% 22% 33% 62%

ia - progress as on 27.07.11
Actual completed as on 27.07.11 ( in % ) Phase 1

Remarks

35% 95% 75% 5% 90% 75% 100% 100% 100% 100% 100% 95% 50% 80% 60% 75% 0% 60% 60% 70%

Only 8 rooms framing is done, no MEP clearance for gypsum board, rooms wiring pending, HVAC canvas/grills/fcu drain pending), Sprinkler rework is pending.

Marble is awaited, FCU drain issue. Marble/wash basins awaited. Services ceiling clearances still pending. Marble is awaited Shortage of manpower, Glazing side is not covered No services clearance( flooring will be done after false ceiling)

Balcony pending for rainwater

Testing 0%, Sprinkler 50 % FCU with heater not received, FCU drain no clearance

No MEP clearance for gypsum board, rooms wiring pending, HVAC canvas/grills/fcu drain pending), Sprinkler rework is pending, Shortage of manpower Shortage of manpower Clearance only for 12 rooms given by MEP Marble/wash basins awaited. Services ceiling clearances still pending. Marble is awaited Shortage of manpower, Glazing side is not covered No services clearance( flooring will be done after false ceiling) Shortage of manpower

75% 100% 100% 100% 100% 100% 95% 50% 70% 60% 60% 75% 100% 100% 100% 100% 100% 70% 50% 35% 50% 40% 20% 30% 20% 30% 69% 35% Phase II

Balcony pending for rainwater

Testing 0%, Sprinkler 50 % FCU with heater not received, FCU drain no clearance

Shortage of manpower

No MEPClearance

Shortage of manpower Balcony pending for rainwater

Corner room is pending Testing 0%, Sprinkler 50 % Piping is done, duct material not available 0.5 Shortage of Manpower No MEPClearance & shortage of manpower

Shortage of manpower, shortage of materials ( FCU's , cisterns & fire dampers0

56% 56%

33% 56% 33% 72% 30% 30% 22% 33% 22% 33% 61% 20% 11% 11% -

Shortage of manpower & Materials

shortage of materials & Manpower

shortage of materials & Manpower

S-ar putea să vă placă și