Output Ratings
Generating Set Model 380-415V,50Hz Prime* 60.0 kVA 48.0 kW 480V, 60 Hz 68.8 kVA 55.0 kW * Refer to ratings definitions on page 4. Ratings at 0.8 power factor. Standby* 65.0 kVA 52.0 kW 75.0 kVA 60.0 kW
Technical Data
Engine Make & Model: Alternator Model: Base Frame Type: Circuit Breaker Type: Frequency: Engine Speed: RPM Fuel Tank Capacity: litres (US gal) Fuel Consumption: Prime l/hr (US gal/hr) Fuel Consumption: Standby l/hr (US gal/hr) Perkins 1103A-33TG2 LL2014H Heavy Duty Fabricated Steel 3 Pole MCB / 3 Pole MCCB 50 Hz 1500 60 Hz 1800
175 (46.2) 13.8 (3.6) 15.1 (4.0) 15.9 (4.2) 17.4 (4.6)
FG Wilson has manufacturing facilities in the following locations: Northern Ireland Brazil China India USA
With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network. To contact your local Sales Office please visit the FG Wilson website at www.FGWilson.com
P60P3 / P65E3
Air System
Air Filter Type: Combustion Air Flow: m/min (cfm) -Standby: -Prime: Max. Combustion Air Intake Restriction: kPa (in H2O)
50 Hz
60 Hz
Replaceable Element 3.9 (138) 3.8 (134) 8.0 (32.1) 4.8 (170) 4.7 (166) 8.0 (32.1)
Cooling Method: Governing Type: Governing Class: Compression Ratio: Displacement: l (cu.in) Bore/Stroke: mm (in) Moment of Inertia: kg m (lb. in) Engine Electrical System: -Voltage/Ground: -Battery Charger Amps: Weight: kg (lb) - Dry: - Wet:
Water Mechanical ISO 8528 G2 17.25:1 3.3 (201.4) 105.0 (4.1)/127.0 (5.0) 1.14 (3896) 12/Negative 65 420 (926) 438 (966)
Radiator Cooling Air Flow: m/min (cfm) External Restriction to Cooling Air Flow: Pa (in H2O) 120 (0.5) 120 (0.5) 110.4 (3899) 145.8 (5149)
Cooling System
Cooling System Capacity: l (US gal) Water Pump Type: Heat Rejected to Water & Lube Oil: kW (Btu/min) -Standby: -Prime: Heat Radiation to Room:
50 Hz
60 Hz
10.2 (2.7)
10.2 (2.7)
Centrifugal
37.7 (2144) 35.2 (2002) 16.7 (950) 15.2 (864) 1.0 (1.3)
42.8 (2434) 41.0 (2332) 17.9 (1018) 17.0 (967) 1.7 (2.3)
Performance
Engine Speed: RPM Gross Engine Power: kW (hp) -Standby: -Prime: BMEP: kPa (psi) -Standby: -Prime: Regenerative Power: kW
50 Hz
1500 60.5 (81.0) 55.0 (74.0) 1467.0 (212.8) 1333.0 (193.4) 7.0
60 Hz
1800 69.6 (93.0) 63.3 (85.0) 1407.0 (204.0) 1279.0 (185.5) 9.0 kW (Btu/min)
-Standby: -Prime:
Cooling system designed to operate in ambient conditions up to 50C (122F). Contact your local FG Wilson dealer for power ratings at specific site conditions.
Lubrication System
Oil Filter Type: Total Oil Capacity l (US gal): Spin-On, Full Flow 8.3 (2.2) 7.8 (2.1) AP1 CG4 15W-40 Water
Fuel System
Fuel Filter Type: Recommended Fuel: Fuel Consumption: l/hr (US gal/hr) 110% Load Prime 50 Hz 60 Hz 15.1 (4.0) 17.4 (4.6) 13.8 (3.6) 15.9 (4.2) 10.3 (2.7) 12.0 (3.2) 7.3 (1.9) 8.8 (2.3) 100% Load 75% Load 50% Load Replaceable Element Class A2 Diesel
Exhaust System
Silencer Type: Silencer Model & Qty: Pressure Drop Across Silencer System: kPa (in Hg) Silencer Noise Reduction
50 Hz
Level 1 SD80 (1) 0.98 (0.289) 19 10.0 (3.0) 10.4 (367) 10.1 (357) 571 (1060) 557 (1035)
60 Hz
1.22 (0.360) 18 15.0 (4.4) 12.5 (441) 11.8 (417) 564 (1047) 534 (993)
Standby 50 Hz 60 Hz 15.1 (4.0) 17.4 (4.6) 11.1 (2.9) 13.0 (3.4) 7.7 (2.0) 9.3 (2.5)
Level: dB Max. Allowable Back Pressure: kPa (in. Hg) Exhaust Gas Flow: m/min (cfm) -Standby: -Prime: Exhaust Gas Temperature: C (F) -Standby: -Prime:
(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
P60P3 / P65E3
60 Hz
240/120V 208/120V 230/115V 440/254V 220/127V
148
139
128
164
163
109
127
119
140
300
300
300
300
300
300
300
300
300
Xd X'd X''d
Reactances shown are applicable to prime ratings * Based on 30% voltage dip. ** With optional Permanent Magnet generator or AREP excitation.
Operating Data
Overspeed: RPM Voltage Regulation (steady state) (%): Wave Form NEMA = TIF: Wave Form IEC = THF: Total Harmonic Content LL/LN: Radio Interference: 2250 +/- 0.5 50 2.0% 4.0%
Radiant Heat: kW (Btu/min) -50 Hz: -60 Hz: 5.8 (330) 6.9 (392)
P60P3 / P65E3
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, 1800 RPM
Voltage
kVA
415/240V 400/230V 380/220V 230/115V 220/127V 220/110V 200/115V 60.0 60.0 60.0 60.0 60.0 60.0 60.0
Prime
kW
48.0 48.0 48.0 48.0 48.0 48.0 48.0
Standby
kVA
65.0 65.0 65.0 65.0 65.0 65.0 65.0
Voltage
kW
52.0 52.0 52.0 52.0 52.0 52.0 52.0 480/277V 220/127V 380/220V 240/120V 230/115V 440/254V 220/110V 208/120V 240/139V
Prime
kVA
68.8 68.8 68.7 68.8 68.8 68.8 68.7 68.8 68.8
Standby
kW
55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0
kVA
75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0
kW
60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0
Definitions
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Dimensions: mm (in)
2150 (84.6) 752 (29.6) 1366 (53.8)
General Data
Documents
A full set of operation and maintenance manuals and circuit wiring diagrams.
Warranty
All equipment carries full manufacturer's warranty. Extended warranty terms available. For details on warranty cover please contact your local dealer, or visit our website: www.FGWilson.com
In line with our policy of continuous product development, we reserve the right to change specification without notice.
P60P3 / P65E3/4PP/0209/GB