Regional Office, 1st Floor, Shankar Shopping Complex,Krishna Nagar Main Road, Kurnool – 518 002
To
Sir ,
Sub: PCB – RO – KNL – CDCC - CFO application of M/s Vakkal Impex Pvt. Ltd, unit-B,
Sy.No.78, Devarapalli(v), Hindupur(M), Anantapur Dist. – Verification report –
Regarding.
Ref: 1) CFE Order No. ATP – 102/PCB/ZOK/C Estt/2006 – 1267, dt: 24-02-2006
2) Lr.No.617/A1/2007, dt: 06-03-2007, received through General Manager,
District Industries Centre, Anantapur on 12-03-2007
3) Clarification sought on 12-03-2007
4) Industry letter dated: 11-04-2007
The details of the industry and inspection report are submitted as below:
General Details:
1 Name and Address of the industry M/s Vakkal Impex Pvt. Ltd, unit-B,
Sy.No.78, Devarapalli(v), Hindupur(M),
Anantapur Dist.
With Tel. No,
08556 – 329659
E-mail.
vakkal_aluminium@yahoo.com
Page 1 of 7
5 Status of E.C
I Line of Activity as per EIA Notification. N.A
II Environmental Clearance order No.
and date
(Copy shall be enclosed).
III Violations of EIA Notification, If any.
6 I Inspection conducted by A.E.E-II
II Representative of Industry present Mr. Acharya, Plant Incharge
III Date of Inspection 15-03-2007
CFO Details
7 Raw materials / Fuels required for production at Consented capacity per Day / Month.
Note : Should not be mentioned as “ enclosed with the application “
S.No Name of the Major Raw material / (Per / Month ) for each product
material used in the Activity
1 Aluminium scrap & Aluminium scrap with 35 TPD
Iron attachments
9 Water consumption.
I Source of water supply Borewell
(River / Bore wells / Public supply)
S. Purpose Quantity in KLD
no
1. Process / Scrubbing 2.0 KLD
2. Washings ---
3. Boiler Feed ---
4 Industrial Cooling (Makeup) / 2.0 KLD
Humidification / Water spraying).
5 Gardening / Irrigation. 1.0 KLD
6 Others (to be specified) ---
7 Domestic 2.0 KLD
Total: 7.0 KLD
II. Status of Functioning of Water Meters Not provided
Page 2 of 7
11 Out let – as per CFE / CFO order dt.
iii. For Domestic waste water: Septic tank followed by soak pit
13 Water Cess
I Returns filed upto (Month & Year) February 2007
II Assessment issued upto (Month & ---
Year)
III Assessment paid upto (Month & Year) ---
IV Assessment amount due (In Rs.) ---
14 Air pollution:
Page 3 of 7
17 Inspection Officer’s Remarks: M/s Vakkal Impex Pvt. Ltd, unit-B, had obtained CFE
order of the Board on 24-02-2006 for establishment of alluminium Alloy Ingots &
Aluminium Extruder and drawn sections to the tune of 30 TPD & 7 TPD respectively. The
industry had commissioned the unit in the month of March 2006 (It was informed during
inspection on 08-11-2006). This office issued a notice on 09-11-2006 for operating the
industry without CFO of the Board and without providing necessary air pollution control
equipment. The industry has submitted a letter dt: 15-02-2007, stating that they have
taken Demand Draft or Rs. 18,400/- towards consent fee and will submit CFO application
within a week time. The industry has submitted CFO application at District Industries
Centre, Anantapur under Single Window Clearances on 06-03-2007 received in this office
on 12-03-2007. This office sought clarification on 12-03-2007 after scrutinizing on the
following points.
The main source of water pollution due to this unit are cooling section,
scrubbing section and domestic usage. The industry generates hazardous waste
i.e., waste oil from D.G sets and oil sludge from furnace oil storage tank and
proposed to dispose the same authorized parties. The industry generates 0.2 TPD
of iron waste & 0.45 TPD of dross as solid waste against production of 7.5 TPD. It
is reported that the industry is disposing the iron waste to the steel units and
disposing the dross as land filling.
During inspection, the stack monitoring was carried out at stack attached to
the oil fired furnace of capacity – 5 T/8hr. and the SPM concentration was found to
be 105.32 µg/Nm3.
I Maintenance of ETP / APC : Industry has provided wet scrubber as air pollution
control equipment attached to oil fired furnace of capacity – 5 T/8hr. and
operating at the time of inspection.
II Records Maintained
• ETP Log Book.
• Stack Monitoring Report.
• Ambient Air Quality Monitoring report.
• Energy consumption records.
• Water meter readings.
Page 4 of 7
18 Compliance of the industry on CFE (Schedule- A & B) Conditions for Fresh CFO
/ Schedule – B conditions for renewal.
CFE Order No. ATP – 102/PCB/ZOK/C Estt/2006 – 1267, dt: 24-02-2006
S.
Condition Compliance
No.
1 Industry shall install the air pollution : Industry has provided air pollution
control equipment as proposed to control equipment i.e., wet scrubber to
arrest air pollution in the surrounding oil fired furnace of capacity 5 T/8hr.
area. and proposed to provide air pollution
control equipment to 3T/8hr. furnace
before commissioning.
2 Industry shall meet the Boards AAQ : Complied for stack emissions
and stack monitoring standards.
3 Industry shall dispose the solid waste : Industry is storing the solid waste i.e.,
in scientific manner on their own iron & dross within the premises.
premises.
S.
Condition Compliance
No.
---
---
S.
Condition Compliance
No.
--- ---
S.
CREP Recommendations Compliance
No.
--- ---
Page 5 of 7
III. Mitigation Measures (Where The industry has to operate air pollution
significant adverse effects are control equipment continuously and also they
identified, description of the should provide air pollution contril equipment
measures to be taken to avoid, to the oil fired furnace of capacity 3T/8hr. and
reduce or remedy those effects). for 7 crusibles. The industry should provide
ETP for treating the scrubbing water. The
industry should develop greenbelt in the
vacant places of the plant along with all
around the boundary. The industry has to
handle the hazardous waste in a safe manner.
The industry has not submitted the hazardous
waste application.
Common TSDF –
Common HW Incinerator –
For recycle / reused -
viii) Whether industry has submitted annual N.A
returns, date of latest submission.
Page 6 of 7
xiii) Steps taken by industry towards waste ---
minimization and cleaner production.
This is submitted for favour of kind information and taking necessary action.
1. CFO applications Y
along with enclosures
2. CFE/ CFO order copy N
3. Effluents analysis report N
4. Stack Emissions analysis Y
reports
Yours faithfully,
ENVIRONMENTAL ENGINEER