BULLETIN 140U
Bulletin 140U
Table of Contents
Product Selection
100 A, G-Frame..........
Product Selection
125 A, H-Frame..........
Product Selection
250 A, J-Frame...........
Product Selection
400 A, K-Frame ..........
Product Selection
600 A, L-Frame...........
Product Selection
800 A, M-Frame .........
Product Selection
1200 A, N-Frame .......
9
16
21
26
31
36
Approvals
Conformity to Standards
UL Listed
CSA Certified
CE
KEMA-KEUR
UL 489
CSA 22.2, No. 5
IEC 60947-2
Frame Reference
G-Frame
H-Frame
J-Frame
K-Frame
L-Frame
M-Frame
Max. Current In
100 A
125 A
250 A
400 A
600 A
800 A
N-Frame
1200 A
Current Range
15100 A
15125 A
70250 A
100400 A
300600 A
300800 A
6001200 A
Thermal Magnetic
Electronic:
LS
LSI
LSG
LSIG
Interrupting Ratings:
380415V (Icu)
14
22
25
40
70
25
40
70
40
65
100
45
70
50
70
50
70
100
480V
14
22
25
35
65
25
35
65
35
65
100
35
65
50
65
50
65
100
600V
14
22
18
22
25
18
18
25
25
35
50
25
35
25
35
25
35
50
690V (Icu)
14
22
10
13
18
20
25
20
25
20
25
30
Rotary Operators
Internal Control
Modules
(Field installed)
Standards Compliance
UL 489
UL File E197878,
Guide No. DIV Q
IEC 60947-2
CE
KEMA-KEUR
Bulletin 140U
140U H
a
3 C50 H
Bulletin No.
Protection Type
Code
Description
Code
Description
Code
Description
140U
1 Auxiliary contact
2 Auxiliary contacts
1 Alarm contact
b
Frame/Rating
Code
Description
125 A
250 A
400 A
600 A
800 A
1200 A
c
Interrupting Rating/Breaking Capacity
(based on Ic at 480V)
Code
Description
2029 kA
3039 kA
5059 kA
6069 kA
8089 kA
100 kA
e
Poles
Code
Description
1 poles
2 poles
3 poles
f
Current Range
Code
Description
10 rr. A
100 rr0 A
1000 rr00 A
Code
Description
h
Voltage Code
See the following pages for
voltage code descriptions:
All frame sizes
Page 41
Bulletin 140U
Frames
140U
a
Bulletin No.
Protection Type
Code
Description
140U
b
Frame/Rating
Code
Description
250 A
400 A
600 A
800 A
Code
Description
2029 kA
3039 kA
5059 kA
6069 kA
8089 kA
100 kA
Code
Description
Frame Only
e
Poles
Code
Description
3 poles
Trip Units
140U
a
3 D25
Bulletin No.
Trip Unit
Poles
Code
Description
Code
Description
Code
Description
140U
Trip Unit
3 poles
Frame/Rating
Protection Type
Current Range
Code
Description
Code
Description
Code
250 A
10 rr. A
400 A
100 rr0 A
600 A
1000 rr00 A
800 A
Description
Bulletin 140U
Note: Accessories cannot be field installed to the G-Frame circuit breakers. Circuit breakers with 1 auxiliary contact are also
available.
Thermal Trip
[A]
Ir = In (Fixed)
Magnetic Trip
[A]
Im = 10 x In
15
20
25
30
35
40
45
50
15
20
25
30
35
40
45
50
150
200
250
300
350
400
450
500
240V AC
65
65
65
65
65
65
65
65
480V AC
14
14
14
14
14
14
14
14
2 Poles w/
2 Poles
1 aux. contact
Interrupt Rating [kA] 9
125/250 V DC 9
Cat. No.
Cat. No.
10
140U-G1C2-C15 140U-G1C2-C15-A
140U-G1C2-C20 140U-G1C2-C20-A
10
140U-G1C2-C25 140U-G1C2-C25-A
10
140U-G1C2-C30 140U-G1C2-C30-A
10
140U-G1C2-C35 140U-G1C2-C35-A
10
140U-G1C2-C40 140U-G1C2-C40-A
10
140U-G1C2-C45 140U-G1C2-C45-A
10
140U-G1C2-C50 140U-G1C2-C50-A
10
Thermal Trip
[A]
Ir = In (Fixed)
Magnetic Trip
[A]
Im = 10 x In
15
20
25
30
35
40
45
50
60
70
80
90
100
15
20
25
30
35
40
45
50
60
70
80
90
100
150
200
250
300
350
400
450
500
600
700
800
900
1000
240V AC
65
65
65
65
65
65
65
65
65
65
65
65
65
480V AC
22
22
22
22
22
22
22
22
22
22
22
22
22
3 Poles w/ 1 aux.
3 Poles
contact
Interrupt Rating [kA] 9
125/250 V DC 9
Cat. No.
Cat. No.
10
140U-G2C3-C15 140U-G2C3-C15-A
140U-G2C3-C20 140U-G2C3-C20-A
10
140U-G2C3-C25 140U-G2C3-C25-A
10
140U-G2C3-C30 140U-G2C3-C30-A
10
140U-G2C3-C35 140U-G2C3-C35-A
10
140U-G2C3-C40 140U-G2C3-C40-A
10
140U-G2C3-C45 140U-G2C3-C45-A
10
140U-G2C3-C50 140U-G2C3-C50-A
10
140U-G2C3-C60 140U-G2C3-C60-A
10
140U-G2C3-C70 140U-G2C3-C70-A
10
140U-G2C3-C80 140U-G2C3-C80-A
10
140U-G2C3-C90 140U-G2C3-C90-A
10
140U-G2C3-D10 140U-G2C3-D10-A
10
Bulletin 140U
140U-G-RVM12B
Red/Yellow Handle
140U-G-RVM12R
Qty: 1
140U-G-DRA2
Qty: 1
140U-G-DRA3
Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1
140U-G-PL
Cat. No.
Black Handle
Bulletin 140U
2-Pole Dimensions
.84
[ 21,4 ]
.49
[ 12,5 ]
2.00
[ 50,8 ]
.14
[ 3,6 ]
1.00
[ 25,4 ]
2.42
[ 61,5 ]
.97
[ 24,6 ]
3.22
[ 81,8 ]
1.00
[ 25,4 ]
3.21
[ 81,5 ]
.49
[ 12,4 ]
1.22
[ 30,9 ]
Bulletin 140U
.84
[ 21,3 ]
.36
[ 9,1 ]
.45
[ 11,4 ]
3.00
[ 76,2 ]
3.21
[ 81,4 ]
.16
[ 4,1 ]
1.00
[ 25,4 ]
4.88
[ 123,8 ]
140U
G FRAME
3.22
[ 81,7 ]
1.00
[ 25,4 ]
1.00
[ 25,4 ]
2.41
[ 61,2 ]
.45
[ 11,4 ]
.36
[ 9,1 ]
2.83
[ 71,8 ]
1.22
[ 31 ]
Bulletin 140U
Rated
Current
In [A]
Magnetic Trip
[A]
Im = 10 x In
240V
277V
Cat. No.
15
500
25
25
25
18 kA
140U-H1C1-C15
20
500
25
25
25
18 kA
140U-H1C1-C20
25
500
25
25
25
18 kA
140U-H1C1-C25
30
500
25
25
25
18 kA
140U-H1C1-C30
35
500
25
25
25
18 kA
140U-H1C1-C35
40
500
25
25
25
18 kA
140U-H1C1-C40
45
500
25
25
25
18 kA
140U-H1C1-C45
50
500
25
25
25
18 kA
140U-H1C1-C50
60
600
25
25
25
18 kA
140U-H1C1-C60
70
700
25
25
25
18 kA
140U-H1C1-C70
80
800
25
25
25
18 kA
140U-H1C1-C80
90
900
25
25
25
18 kA
140U-H1C1-C90
100
1000
25
25
25
18 kA
140U-H1C1-D10
110
1100
25
25
25
18 kA
140U-H1C1-D11
125
1250
25
25
25
18 kA
140U-H1C1-D12
220240V
Rated
Current
In [A]
Magnetic Trip
[A]
Im = 10 x In
240V
480V
600/347V
Cat. No.
15
500
35
35
25
25
35
25
18
140U-H2C2-C15
20
500
35
35
25
25
35
25
18
140U-H2C2-C20
25
500
35
35
25
25
35
25
18
140U-H2C2-C25
30
500
35
35
25
25
35
25
18
140U-H2C2-C30
35
500
35
35
25
25
35
25
18
140U-H2C2-C35
40
500
35
35
25
25
35
25
18
140U-H2C2-C40
45
500
35
35
25
25
35
25
18
140U-H2C2-C45
50
500
35
35
25
25
35
25
18
140U-H2C2-C50
60
600
35
35
25
25
35
25
18
140U-H2C2-C60
70
700
35
35
25
25
35
25
18
140U-H2C2-C70
80
800
35
35
25
25
35
25
18
140U-H2C2-C80
90
900
35
35
25
25
35
25
18
140U-H2C2-C90
100
1000
35
35
25
25
35
25
18
140U-H2C2-D10
110
1100
35
35
25
25
35
25
18
140U-H2C2-D11
125
1250
35
35
25
25
35
25
18
140U-H2C2-D12
220240V
380415V
500V
690V
Bulletin 140U
Rated
Current
In [A]
Thermal Trip
[A]
Ir = In (Fixed)
Magnetic Trip
[A]
Im = 10 x In
220240V
380415V
240V
480V
600/347V
Cat. No.
15
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C15
20
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C20
25
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C25
30
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C30
35
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C35
40
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C40
45
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C45
50
Fixed
500
85
43
40
30
85
35
22
140U-H3C2-C50
60
Fixed
600
85
43
40
30
85
35
22
140U-H3C2-C60
70
Fixed
700
85
43
40
30
85
35
22
140U-H3C2-C70
80
Fixed
800
85
43
40
30
85
35
22
140U-H3C2-C80
90
Fixed
900
85
43
40
30
85
35
22
140U-H3C2-C90
100
Fixed
1000
85
43
40
30
85
35
22
140U-H3C2-D10
110
Fixed
1100
85
43
40
30
85
35
22
140U-H3C2-D11
125
Fixed
1250
85
43
40
30
85
35
22
140U-H3C2-D12
500V
690V
Rated
Current
In [A]
Thermal Trip
[A]
Ir = In (Fixed)
Magnetic
Trip [A]
Im = 10 x In
240V
480V
600/347V
Cat. No.
15
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C15
20
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C20
25
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C25
30
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C30
35
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C35
40
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C40
45
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C45
50
Fixed
500
100
50
70
35
100
65
25
140U-H6C2-C50
60
Fixed
600
100
50
70
35
100
65
25
140U-H6C2-C60
70
Fixed
700
100
50
70
35
100
65
25
140U-H6C2-C70
80
Fixed
800
100
50
70
35
100
65
25
140U-H6C2-C80
90
Fixed
900
100
50
70
35
100
65
25
140U-H6C2-C90
100
Fixed
1000
100
50
70
35
100
65
25
140U-H6C2-D10
110
Fixed
1100
100
50
70
35
100
65
25
140U-H6C2-D11
125
Fixed
1250
100
50
70
35
100
65
25
140U-H6C2-D12
220240V
380415V
500V
690V
10
Thermal Trip
[A]
Ir = In (Fixed)
15
20
25
30
35
40
40
50
60
70
80
90
100
110
125
Magnetic Trip
[A]
Im = 10 x In
500
500
500
500
500
500
500
500
600
700
800
900
1000
1100
1250
380415V
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
500V
22
22
22
22
22
22
22
22
22
22
22
22
22
690V
17
17
17
17
17
17
17
17
17
17
17
17
17
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Cat. No.
140U-H2C3-C15
140U-H2C3-C20
140U-H2C3-C25
140U-H2C3-C30
140U-H2C3-C35
140U-H2C3-C40
140U-H2C3-C45
140U-H2C3-C50
140U-H2C3-C60
140U-H2C3-C70
140U-H2C3-C80
140U-H2C3-C90
140U-H2C3-D10
140U-H2C3-D11
140U-H2C3-D12
Bulletin 140U
Thermal Trip
[A]
Ir = In (Fixed)
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
Magnetic Trip
[A]
Im = 10 x In
500
500
500
500
500
500
500
500
600
700
800
900
1000
1100
1250
380415V
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
40
30
500V
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Cat. No.
140U-H3C3-C15
140U-H3C3-C20
140U-H3C3-C25
140U-H3C3-C30
140U-H3C3-C35
140U-H3C3-C40
140U-H3C3-C45
140U-H3C3-C50
140U-H3C3-C60
140U-H3C3-C70
140U-H3C3-C80
140U-H3C3-C90
140U-H3C3-D10
140U-H3C3-D11
140U-H3C3-D12
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Cat. No.
140U-H6C3-C15
140U-H6C3-C20
140U-H6C3-C25
140U-H6C3-C30
140U-H6C3-C35
140U-H6C3-C40
140U-H6C3-C45
140U-H6C3-C50
140U-H6C3-C60
140U-H6C3-C70
140U-H6C3-C80
140U-H6C3-C90
140U-H6C3-D10
140U-H6C3-D11
140U-H6C3-D12
690V
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Thermal Trip
[A]
Ir = In (Fixed)
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
Magnetic
Trip [A]
Im = 10 x In
500
500
500
500
500
500
500
500
600
700
800
900
1000
1100
1250
380415V
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
70
35
500V
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
690V
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Thermal Trip
[A]
Ir = In (Fixed)
Magnetic
Trip [A]
Im = 10 x In
1250
380415V
70
35
500V
35
690V
18
Cat. No.
140U-H6S3-D12
11
Bulletin 140U
Diagram
Cat. No.
140U-H-EA1
(1) 1a-1b
(2) 1a-1b
Mounting Location
140U-H-EA2
140U-H-ER1
(1) 1a-1b
(1) 1M (make)1B (break)
140U-H-EA1R1
2460V,
50/60/DC
140U-H-SNJ
110240V,
50/60/DC
140U-H-SND
380440V AC,
220250V DC
140U-H-SNN
380600V,
50/60 Hz
140U-H-SNB
24V, 50/60 Hz
140U-H-UJ
110127V,
50/60 Hz
140U-H-UD
208240V,
50/60 Hz
140U-H-UA
380500V,
50/60 Hz
140U-H-UB
525600V,
50/60 Hz
12
140U-H-UC
Bulletin 140U
Cat. No.
140U-H-TC2
140U-H-TC4
Terminal Shields
IP20 Ingress Protection Rating
140U-H-TS
3 ft (0.9 m) Cable
140U-H-FCX03
4 ft (1.3 m) Cable
140U-H-FCX04
6 ft (1.9 m) Cable
140U-H-FCX06
10 ft (3.0 m) Cable
140U-H-FCX10
3 ft (0.9 m) Cable
140U-H-FCS03
4 ft (1.2 m) Cable
140U-H-FCS04
6 ft (1.9 m) Cable
140U-H-FCS06
10 ft (3.0 m) Cable
140U-H-FCS10
Black Handle
140U-H-RVM12B
Red/Yellow Handle
140U-H-RVM12R
Black Handle
140U-H-RVM21B
Red/Yellow Handle
140U-H-RVM21R
Black Handle
140U-H-NVM12B
Red/Yellow Handle
140U-H-NVM12R
Black Handle
140U-H-NVM21B
Red/Yellow Handle
140U-H-NVM21R
Motor Operator
Remotely opens, closes, and resets the circuit breaker
110240V AC
140U-H-EOPD
Motor Operator
Remotely opens, closes, and resets the circuit breaker
24V DC
140U-H-EOPZ
140U-H-MHM
Mounting Hardware
(4) M4 - 0.7 x 75 mm
13
Bulletin 140U
140U-H-RCB
Red/Yellow Handle
140U-H-RCR
Qty: 1
140U-H-ECM
Phase Barriers
Provides additional phase clearance when special connections that
extend past the circuit breaker housing are required
Qty: 2
140U-H-PB
Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1
140U-H-PL
Qty: 1
140U-H-PAD3
Qty: 1
140U-H-PDK
Qty: 1
140U-H-DRA
14
Cat. No.
Black Handle
140U-H-MTL3A
Qty: 3
140U-H-MTL3AN
140U-H-MTL6A
Qty: 3
140U-H-MTL6AN
Bulletin 140U
0.907
TOP
FNT
2.497
0.984
FNT
5.50
3.812
RGT
RGT
TOP
2.913
3.476
15
Bulletin 140U
0.8524
0.4179
TOP
3.414
FNT
1.973
FNT
0.168
RGT
RGT
TOP
3.812
1.007
FNT
2.9725
16
TOP
Bulletin 140U
Line End
.50
.50
(12.70) (12.70)
.45
(11.43)
.78
(19.81)
.09
(2.29)
.56
(14.22)
.22
(5.59)
Attachment
Leads Side
Exit Point
5.50
(139.70)
Push to
Trip Button
3.81
(96.78)
3.03
(76.96)
R2.13
Handle
C
L
1.73
(43.94)
.17
(4.32)
.15
(3.81)
E
D
1.38
(35.05)
2.18
(55.37)
.22
(5.59)
A
B
.17
(4.32)
1.08
(27.43)
.72
(18.29)
.57
(14.48)
.55
(13.97)
.09
(2.29)
.77
(19.56)
.03
(0.76)
1.42
(36.07)
2.77
(70.36)
2.93
2.99 (74.42)
(75.95)
C
1.00
(25.40)
1.00
(25.40)
1.21
(30.73)
3.00
(76.20)
1.50
(38.10)
Breaker Status
.44
(11.18)
On
2.71
(68.83)
2.53
(64.26)
3.46
(87.88)
2.83
(71.88)
2.75
(69.85)
Off
1.54
(39.12)
1.62
(41.15)
3.46
(87.88)
1.66
(42.16)
1.84
(46.74)
Tripped
2.33
(59.18)
2.23
(56.64)
3.54
(89.92)
2.46
(67.48)
2.45
(62.23)
Reset
1.39
(35.31)
1.49
(37.85)
3.42
(86.87)
1.52
(38.61)
1.70
(43.18)
.47
(11.94)
Attachment
Leads Rear
Exit Point
Dimension
A
.94
(23.88)
1.44
(36.58)
.67
(17.02)
17
Bulletin 140U
Breaker Frames
Breaking Capacity (50 Hz)
Icu /Ics [kA]
Rated
Current
In [A]
220240V
65
250
380415V
65
25
500V
25
690V
20
12
240V
480V
600V
Cat. No.
65
25
18
140U-J2X3
85
85
40
40
35
20
85
35
18
140U-J3X3
100
100
70
70
42
20
100
65
25
140U-J6X3
Trip Units
Electronic
Thermal-Magnetic
Cat. No.
Rated
Operational
Current
In
Thermal Trip
Ir = 0.41.0 x In
Magnetic Trip
Im = 214 x Ir
Protection
Type
Cat. No.
450900
140U-JTD3-C90
50
2050
40700
LS
140U-JTL3-C50
100
5001000
140U-JTD3-D10
50
2050
40700
LSI
140U-JTH3-C50
125
6001250
140U-JTD3-D12
50
2050
40700
LSG
140U-JTG3-C50
150
150
7501500
140U-JTD3-D15
50
2050
40700
LSIG
140U-JTI3-C50
175
175
8751750
140U-JTD3-D17
100
40100
801400
LS
140U-JTL3-D10
200
200
10002000
140U-JTD3-D20
100
40100
801400
LSI
140U-JTH3-D10
225
225
11252250
140U-JTD3-D22
100
40100
801400
LSG
140U-JTG3-D10
250
250
12502500
140U-JTD3-D25
100
40100
801400
LSIG
140U-JTI3-D10
160
63160
1262240
LS
140U-JTL3-D16
Rated
Operational
Current
In
Thermal Trip
Ir = In (Fixed)
Magnetic Trip
Im = 510 x Ir
90
90
100
125
160
63160
1262240
LSI
140U-JTH3-D16
160
63160
1262240
LSG
140U-JTG3-D16
160
63160
1262240
LSIG
140U-JTI3-D16
250
100250
2003500
LS
140U-JTL3-D25
250
100250
2003500
LSI
140U-JTH3-D25
250
100250
2003500
LSG
140U-JTG3-D25
250
100250
2003500
LSIG
140U-JTI3-D25
Rated Operational
Current
In
Breaking Capacity/
Interrupting Rating
[kA]7
Breaking Capacity/
Interrupting Rating
[kA]7
Breaking Capacity/
Interrupting Rating
[kA]7
400V
480V
Cat. No.
400V
480V
Cat. No.
400V
480V
Cat. No.
90
25
25
140U-J2D3-C90
40
35
140U-J3D3-C90
70
65
140U-J6D3-C90
100
25
25
140U-J2D3-D10
40
35
140U-J3D3-D10
70
65
140U-J6D3-D10
125
25
25
140U-J2D3-D12
40
35
140U-J3D3-D12
70
65
140U-J6D3-D12
150
25
25
140U-J2D3-D15
40
35
140U-J3D3-D15
70
65
140U-J6D3-D15
175
25
25
140U-J2D3-D17
40
35
140U-J3D3-D17
70
65
140U-J6D3-D17
200
25
25
140U-J2D3-D20
40
35
140U-J3D3-D20
70
65
140U-J6D3-D20
225
25
25
140U-J2D3-D22
40
35
140U-J3D3-D22
70
65
140U-J6D3-D22
250
25
25
140U-J2D3-D25
40
35
140U-J3D3-D25
70
65
140U-J6D3-D25
7 Full ratings are found in the breaker frames table on this page
18
Bulletin 140U
Breaking
Capacity/
Interrupting
Rating [kA]7
Breaking
Capacity/
Interrupting
Rating [kA]7
Rated
Operational
Current
In
Protection Type
400V
480V
Cat. No.
400V
480V
Cat. No.
400V
480V
Cat. No.
50
LS
25
25
140U-J2L3-C50
40
35
140U-J3L3-C50
70
65
140U-J6L3-C50
50
LSI
25
25
140U-J2H3-C50
40
35
140U-J3H3-C50
70
65
140U-J6H3-C50
50
LSG
25
25
140U-J2G3-C50
40
35
140U-J3G3-C50
70
65
140U-J6G3-C50
50
LSIG
25
25
140U-J2I3-C50
40
35
140U-J3I3-C50
70
65
140U-J6I3-C50
100
LS
25
25
140U-J2L3-D10
40
35
140U-J3L3-D10
70
65
140U-J6L3-D10
100
LSI
25
25
140U-J2H3-D10
40
35
140U-J3H3-D10
70
65
140U-J6H3-D10
100
LSG
25
25
140U-J2G3-D10
40
35
140U-J3G3-D10
70
65
140U-J6G3-D10
100
LSIG
25
25
140U-J2I3-D10
40
35
140U-J3I3-D10
70
65
140U-J6I3-D10
160
LS
25
25
140U-J2L3-D16
40
35
140U-J3L3-D16
70
65
140U-J6L3-D16
160
LSI
25
25
140U-J2H3-D16
40
35
140U-J3H3-D16
70
65
140U-J6H3-D16
160
LSG
25
25
140U-J2G3-D16
40
35
140U-J3G3-D16
70
65
140U-J6G3-D16
160
LSIG
25
25
140U-J2I3-D16
40
35
140U-J3I3-D16
70
65
140U-J6I3-D16
250
LS
25
25
140U-J2L3-D25
40
35
140U-J3L3-D25
70
65
140U-J6L3-D25
250
LSI
25
25
140U-J2H3-D25
40
35
140U-J3H3-D25
70
65
140U-J6H3-D25
250
LSI
25
25
140U-J2G3-D25
40
35
140U-J3H3-D25
70
65
140U-J6G3-D25
250
LSIG
25
25
140U-J2I3-D25
40
35
140U-J3I3-D25
70
65
140U-J6I3-D25
Thermal Trip
Ir = In [A]
Magnetic Trip
[A]
Im = 10 x In
250
2500
380415V
70
70
Interrupting Rating
(60 Hz) [kA]
500V
42
690V
20
240V
100
480V
65
600V
25
Cat. No.
140U-J6S3-D25
19
Bulletin 140U
Diagram
Cat. No.
140U-H-EA1
(1) 1a-1b
(2) 1a-1b
Mounting Location
140U-H-EA2
140U-J-ER1
140U-JEA1R1
(1) 1a-1b
(1) 1M (make)-1B (break)
Right side ONLY
2460V, 50/60/DC
140U-H-SNJ
110240V, 50/60/DC
140U-H-SND
140U-H-SNN
380600V, 50/60 Hz
140U-H-SNB
24V, 50/60 Hz
140U-H-UJ
110127V, 50/60 Hz
140U-H-UD
208240V, 50/60 Hz
140U-H-UA
380500V, 50/60 Hz
140U-H-UB
525600V, 50/60 Hz
140U-H-UC
Terminal Lugs
Description
Terminal Lugs
20
Frame Size
Cat. No.
Qty: 1
140U-J-TLA1
Qty: 1
140U-J-TLS1
Bulletin 140U
Cat. No.
Terminal Shields
IP20 Ingress Protection Rating
140U-J-TS
3 ft (0.9 m) Cable
140U-J-FCX03
4 ft (1.3 m) Cable
140U-J-FCX04
6 ft (1.9 m) Cable
140U-J-FCX06
10 ft (3.0 m) Cable
140U-J-FCX10
3 ft (0.9 m) Cable
140U-J-FCS03
4 ft (1.2 m) Cable
140U-J-FCS04
6 ft (1.9 m) Cable
140U-J-FCS06
10 ft (3.0 m) Cable
140U-J-FCS10
Black Handle
140U-J-RVM12B
Red/Yellow Handle
140U-J-RVM12R
Black Handle
140U-J-RVM21B
Red/Yellow Handle
140U-J-RVM21R
Black Handle
140U-J-NVM12B
Red/Yellow Handle
140U-J-NVM12R
Black Handle
140U-J-NVM21B
Red/Yellow Handle
140U-J-NVM21R
Black Handle
140U-J-RCB
Red/Yellow Handle
140U-J-RCR
140U-J-ECM
Phase Barriers
Provides additional phase clearance when special connections that extend past the circuit
breaker housing are required
Qty: 2
140U-J-PB
Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1
140U-J-PL
Qty: 3
140U-J-MTL3A
Qty: 3
140U-J-MTL6A
140U-J-GFP1503
140U-J-GFP2503
Motor Operator
Remotely opens, closes, and resets the circuit breaker
Mounting Hardware
(4) M4 - 0.7 x 90 mm
140U-J-EOPD
140U-J-EOPZ
140U-J-MHM
21
Bulletin 140U
5.048
.170
4.125
6.000
2.062
4.453
#8-32 TAP
4 HOLES
5.642
1.541
.281
THERMAL ADJUSTMENT
5.500
.256
3.922
.145
7.000
5.500
4 HOLES
BREAKER HANDLE
H
.688
2.750
4.125
1.375
.664
2.062
.688
.203
1.375
PUSH TO TRIP
2.906
.897
.650
TYP(6)
4.125
3.978
.500
2.062
.625
6 HOLES
1.188
TRIP
.594
R2.656
4.0
.500
7.000
BREAKER HANDLE
6.000
4.427
3.570
3.440
3.344
1.375
3.344
3.194
1.906
REF
2.750
.187
.188
1.771
.624
2.062
.125
.198
.625
.625
1.000
.125
7.000
R.188
1.875
3.922
.173
.949
4.938
BREAKER
K HANDLE
.859
1.062
.949
.500
.281
2.000
4.000
.260
22
Bulletin 140U
Breaker Frames
Breaking Capacity (50 Hz)
Icu /Ics [kA]
Rated Current
In
220240V
400
65
65
100
100
200
200
380415V
480V
600V
Cat. No.
40
30
30
10
65
35
25
140U-K3X3
35
35
50
38
13
100
65
35
140U-K6X3
100
100
65
49
18
200
100
50
140U-K0X3
40
500V
690V
Electronic
Rated
Operational
Current In
Magnetic Trip
Im = 28 x Ir
Protection Type
Cat. No.
LS
140U-KTL3-D40
Cat. No.
100
100
5001000
140U-KTD3-D10
125
125
6251250
140U-KTD3-D12
150
150
7501500
140U-KTD3-D15
175
175
8951750
140U-KTD3-D17
200
200
10002000
140U-KTD3-D20
225
225
11252250
140U-KTD3-D22
250
250
12502500
140U-KTD3-D25
300
300
15003000
140U-KTD3-D30
350
350
17503500
140U-KTD3-D35
400
400
20004000
140U-KTD3-D40
400
4003200
2004009
LSI
140U-KTH3-D40
LSG
140U-KTG3-D40
Rating Plugs
Thermal Trip In
Cat. No.
Cat. No.
200
140U-KRP3-D20
300
140U-KRP3-D30
225
140U-KRP3-D22
350
140U-KRP3-D35
250
140U-KRP3-D25
400
140U-KRP3-D40
Breaking
Capacity/
Interrupting
Rating [kA]7
Breaking
Capacity/
Interrupting
Rating [kA]7
Rated
Operati
onal
Current
In
400V
480V
Cat. No.
400V
480V
Cat. No.
400V
480V
Cat. No.
100
40
35
140U-K3D3-D10
65
65
140U-K6D3-D10
100
100
140U-K0D3-D10
125
40
35
140U-K3D3-D12
65
65
140U-K6D3-D12
100
100
140U-K0D3-D12
150
40
35
140U-K3D3-D15
65
65
140U-K6D3-D15
100
100
140U-K0D3-D15
175
40
35
140U-K3D3-D17
65
65
140U-K6D3-D17
100
100
140U-K0D3-D17
200
40
35
140U-K3D3-D20
65
65
140U-K6D3-D20
100
100
140U-K0D3-D20
225
40
35
140U-K3D3-D22
65
65
140U-K6D3-D22
100
100
140U-K0D3-D22
250
40
35
140U-K3D3-D25
65
65
140U-K6D3-D25
100
100
140U-K0D3-D25
300
40
35
140U-K3D3-D30
65
65
140U-K6D3-D30
100
100
140U-K0D3-D30
350
40
35
140U-K3D3-D35
65
65
140U-K6D3-D35
100
100
140U-K0D3-D35
400
40
35
140U-K3D3-D40
65
65
140U-K6D3-D40
100
100
140U-K0D3-D40
Assembled circuit breakers can be created by adding a trip unit and rating plugs (electronic only) to a circuit breaker frame. Example: Cat. No. 140U-K3X3 +
140U-KTL3-D40 + 140U-KRP3-D35
7 Full ratings are found in the breaker frames table on this page
23
Bulletin 140U
Rated
Current
In
400
Thermal Trip
Ir = 0.51.0 x In
Breaking Capacity/
Interrupting Rating
[kA]7
Breaking Capacity/
Interrupting Rating
[kA]7
Protection
400V
480V
Type
Cat. No.
400V
480V
Cat. No.
400V
480V
Cat. No.
140U-K3L3-D40
65
65
140U-K6L3-D40
100
100
140U-K0L3-D40
35
140U-K3H3-D40
65
65
140U-K6H3-D40
100
100
140U-K0H3-D40
35
140U-K3G3-D40
65
65
140U-K6G3-D40
100
100
140U-K0G3-D40
LS
40
35
LSI
40
LSG
40
1004009
Breaking Capacity/
Interrupting Rating
[kA]7
Magnetic Trip
10 x In
400
4000
380415V
65
65
500V
50
690V
38
13
240V
100
480V
65
600V
35
Cat. No.
140U-K6S3-D40
Pkg. Quantity
Terminal Lugs
140U-K-TLA1A
1
140U-K-TLA1
3 (includes shield)
24
140U-K-TLA2
140U-K-TLC1A
1
140U-K-TLC1
3 (includes shield)
140U-K-TLC2
140U-K-TLA2A
3 (includes shield)
Terminal Lugs
Cat. No.
140U-K-TLA1B
3 (includes shield)
140U-K-TLC1B
140U-K-MTL3A
140U-K-MTL6A
Bulletin 140U
Description
Diagram
140U-K-EA1
(1) 1a-1b
(2) 1a-1b
Cat. No.
140U-K-EA2
140U-K-ER1
Auxiliary/Alarm Contact
(AX/AL)
Combination
Combination of auxiliary
contact and alarm contact
140U-KEA1R1
(1) 1a-1b
(1) 1M (make)-1B (break)
Right side ONLY
1224V, 50/60/DC
140U-K-SNJ
140U-K-SND
140U-K-SNN
480600V, 50/60 Hz
140U-K-SNB
24V, 50/60 Hz
140U-K-UJ
110127V, 50/60 Hz
140U-K-UD
208240V, 50/60 Hz
140U-K-UA
380500V, 50/60 Hz
140U-K-UB
25
Bulletin 140U
Cat. No.
Terminal Shields
IP20 Ingress Protection Rating
140U-K-TS
4 ft (1.3 m) Cable
140U-K-FCX04
6 ft (1.9 m) Cable
140U-K-FCX06
10 ft (3.0 m) Cable
140U-K-FCX10
4 ft (1.2 m) Cable
140U-K-FCS04
6 ft (1.9 m) Cable
140U-K-FCS06
10 ft (3.0 m) Cable
140U-K-FCS10
Black Handle
140U-K-RVM12B
Red/Yellow Handle
140U-K-RVM12R
Black Handle
140U-K-RVM21B
Red/Yellow Handle
140U-K-RVM21R
Black Handle
140U-K-NVM12B
Red/Yellow Handle
140U-K-NVM12R
Black Handle
140U-K-NVM21B
Red/Yellow Handle
140U-K-NVM21R
Black Handle
140U-K-RCG
Red/Yellow Handle
140U-K-RCR
140U-K-ECM
Phase Barriers
Provides additional phase clearance when special connections that extend past the circuit
breaker housing are required
Mounting Hardware
(4) M4 - 0.7 x 75 mm
26
Qty: 2
140U-K-PB
140U-K-MHM
Bulletin 140U
Side View
5.490 (139.43)
.844
(21.44)
1.719
(43.66)
Line End
.625
(15.88)
2.813
(71.45)
1.719
(43.66)
.860 (21.84)
2.063 (52.39)
.125
(3.18)
4.125 (104.78)
.093 R
(2.36) R
3.75
(9.52)
ON
.375
(9.52)
Contact
Position
Indicators
Red/1 - On
Green/O - Off
White - T rip
2.438
(61.89)
.750
(19.05)
1.063
(27.00)
.500
(12.70)
8.438
(214.33)
8.875
(225.43)
CL
10.125
(257.18)
OFF
3.875 R
(98.42) R
Handle
.500
(12.70)
1.625
(41.28)
1.625
(41.28)
.250
(6.35)
.063
(1.60)
.062
(1.57)
1.219
(30.96)
.250 R
(6.35) R
1.250
(31.75)
43
4.000
(101.60)
3.563
(90.50)
1.000
(25.40)
3.813
(96.85)
.188
(4.77) R
7.406
(112.70)
.694
(17.63)
5.000(127.00)
2.563
(12.70)
4.437
(65.10)
.500
(12.70)
Trough for
Attachment
Leads
5.966(151.54)
.500
(12.70)
5.766 (146.46)
.625 (15.88)
6 Holes
4.313
(109.55)
3.438
(87.32)
.209
(5.31)
.188
(4.77)
1.734
(44.04)
2.391
(60.73)
39
4.782 (121.46)
.698
.547
(13.89) (17.73)
.188 R
(4.77) R
.500
(12.70)
1.160
(29.49)
.063 (1.60)
.937
(23.80)
.875
(22.25)
.438
(11.13)
.250 (6.35) R
1.063
(27.00)
.750 (19.05)
Wide Conductor
with .391 (9.93)
Dia Hole Line
and Load End
3.812
(96.82)
.188
(4.77)
.766
(19.46)
2.375
(60.33)
.500
(12.70)
Load End
.062
(1.57)
4.062
(103.17)
E
F
Breaker
Status
Dimensions
A
On
5.39
(136.9)
5.20
(132.1)
5.69
(144.5)
5.61
(142.5)
4.72
(119.9)
4.77
(121.2)
Handle
Force
30 lbs.
(13.61 kgs.)
Tripped
4.77
(121.2)
4.69
(119.1)
5.08
(129.0)
5.11
(129.8)
4.89
(124.2)
4.89
(124.2)
N/A
Off
4.16
(105.7)
4.21
(106.9)
4.46
(113.3)
4.64
(117.9)
4.95
(125.7)
4.91
(124.7)
25 lbs.
(11.34 kgs.)
Reset
4.07
(103.4)
4.14
(105.2)
4.57
(116.1)
4.56
(115.8)
4.95
(125.7)
4.90
(124.5)
35 lbs.
(15.87 kgs.)
All handle forces measured approximately 0.125 (3.17) from top of handle.
27
Bulletin 140U
Breaker Frames
Rated
Current In
600
380415V
500V
690V
240V
480V
600V
Cat. No.
85
85
45
45
30
30
20
10
65
35
25
140U-L3X3
100
100
70
70
50
38
25
13
100
65
35
140U-L6X3
Electronic
Rated
Current
In
Thermal Trip
Ir = In (Fixed)
Magnetic Trip
Im = 510 x In
Cat. No.
250
250
12502500
140U-LTD3-D25
300
300
15003000
140U-LTD3-D30
350
350
17503500
140U-LTD3-D35
400
400
20004000
140U-LTD3-D40
500
500
25005000
140U-LTD3-D50
600
600
30006000
140U-LTD3-D60
250
400
600
100250
2002500
160400
3204000
240600
4806000
Protection Type
Cat. No.
LS
140U-LTL3-D25
LSI
140U-LTH3-D25
LSG
140U-LTG3-D25
LSIG
140U-LTI3-D25
LS
140U-LTL3-D40
LSI
140U-LTH3-D40
LSG
140U-LTG3-D40
LSIG
140U-LTI3-D40
LS
140U-LTL3-D60
LSI
140U-LTH3-D60
LSG
140U-LTG3-D60
LSIG
140U-LTI3-D60
Breaking
Capacity/Interrupting
Rating [kA]7
Thermal Trip
Ir = In
400V
480V
Breaking
Capacity/Interrupting
Rating [kA]7
Cat. No.
400V
480V
Cat. No.
250
250
45
35
140U-L3D3-D25
70
65
140U-L6D3-D25
300
300
45
35
140U-L3D3-D30
70
65
140U-L6D3-D30
350
350
45
35
140U-L3D3-D35
70
65
140U-L6D3-D35
400
400
45
35
140U-L3D3-D40
70
65
140U-L6D3-D40
500
500
45
35
140U-L3D3-D50
70
65
140U-L6D3-D50
600
600
45
35
140U-L3D3-D60
70
65
140U-L6D3-D60
7 Full ratings are found in the breaker frames table on this page
28
Bulletin 140U
Breaking Capacity/
Interrupting Rating
[kA]7
Protection
400V
480V
Type
Thermal Trip
Ir = 0.51.0 x In
LS
250
100250
400
160400
600
240600
45
35
Breaking Capacity/
Interrupting Rating
[kA]7
Cat. No.
400V
480V
Cat. No.
140U-L3L3-D25
70
65
140U-L6L3-D25
LSI
45
35
140U-L3H3-D25
70
65
140U-L6H3-D25
LSG
45
35
140U-L3G3-D25
70
65
140U-L6G3-D25
LSIG
45
35
140U-L3I3-D25
70
65
140U-L6I3-D25
LS
45
35
140U-L3L3-D40
70
65
140U-L6L3-D40
LSI
45
35
140U-L3H3-D40
70
65
140U-L6H3-D40
LSG
45
35
140U-L3G3-D40
70
65
140U-L6G3-D40
LSIG
45
35
140U-L3I3-D40
70
65
140U-L6I3-D40
LS
45
35
140U-L3L3-D60
70
65
140U-L6L3-D60
LSI
45
35
140U-L3H3-D60
70
65
140U-L6H3-D60
LSG
45
35
140U-L3G3-D60
70
65
140U-L6G3-D60
LSIG
45
35
140U-L3I3-D60
70
65
140U-L6I3-D60
Magnetic Trip
Im = 10 x In
600
6000
100
380415V
70
70
500V
50
690V
38
25
13
240V
480V
600V
Cat. No.
100
65
35
140U-L6S3-D60
Terminal Lugs
Description
Cat. No.
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(1) 500750 MCM
(1) 240380 mm2
140U-L-TL6A1
Terminal Lugs
Copper Lug
Copper Wire only
(1) 500750 MCM
(1) 240380 mm2
140U-L-TL6C1
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(2) 2500 MCM
(2) 35240 mm2
140U-L-TL6A2
Terminal Lugs
Copper Lug
Copper Wire only
(2) 2500 MCM
(2) 35240 mm2
140U-L-TL6C2
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(1) 2500 MCM
(1) 35240 mm2
Qty: 1
140U-L-TL4A1
Terminal Lugs
Copper Lug
Copper Wire only
(1) 2500 MCM
(1) 35240 mm2
Qty: 1
140U-L-TL4C1
29
Bulletin 140U
Diagram
Cat. No.
140U-H-EA1
(1) 1a-1b
(2) 1a-1b
Mounting Location
140U-H-EA2
140U-J-ER1
Auxiliary/Alarm Contact
(AX/AL)
Combination
Combination of auxiliary
contact and alarm contact
(1) 1a-1b
(1) 1M (make)-1B (break)
140U-JEA1R1
Right side ONLY
2460V, 50/60/DC
140U-H-SNJ
110240V, 50/60/DC
140U-H-SND
140U-H-SNN
380600V, 50/60 Hz
140U-H-SNB
140U-H-UJ
110127V, 50/60 Hz
140U-H-UD
208240V, 50/60 Hz
140U-H-UA
380500V, 50/60 Hz
140U-H-UB
525600V, 50/60 Hz
30
24V, 50/60 Hz
140U-H-UC
Bulletin 140U
Cat. No.
Terminal Shields
IP20 Ingress Protection Rating
140U-L-TS
4 ft (1.3 m) Cable
140U-L-FCX04
6 ft (1.9 m) Cable
140U-L-FCX06
10 ft (3.0 m) Cable
140U-L-FCX10
4 ft (1.2 m) Cable
140U-L-FCS04
6 ft (1.9 m) Cable
140U-L-FCS06
10 ft (3.0 m) Cable
140U-L-FCS10
Black Handle
140U-L-RVM12B
Red/Yellow Handle
140U-L-RVM12R
Black Handle
140U-L-RVM21B
Red/Yellow Handle
140U-L-RVM21R
Black Handle
140U-L-NVM12B
Red/Yellow Handle
140U-L-NVM12R
Black Handle
140U-L-NVM21B
Red/Yellow Handle
140U-L-NVM21R
Black Handle
140U-L-RMX
Qty: 1
140U-L-ECM
Phase Barriers
Provides additional phase clearance when special connections that extend past the circuit
breaker housing are required
Qty: 2
140U-K-PB
400 A
140U-L-GFP4003
600 A
140U-L-GFP6003
140U-L-EOPD
140U-L-EOPZ
140U-L-MHM
Motor Operator
Remotely opens, closes, and resets the circuit breaker
110240V AC
Mounting Hardware
(4) M5 - 0.8 x 100 mm
31
Bulletin 140U
1.72
[ 43,6 ]
10.13
[ 257,2
8.44
[ 214,4
1.72
[ 43,7 ]
3.36
[ 85,3 ]
.22
[ 5,5 ]
1.72
[ 43,7 ]
5.43
[ 137,9
.25
[ 6,4 ]
.97
[ 24,6 ]
1.34
[ 34,1 ]
32
Bulletin 140U
Breaker Frames
Rated
Current
In
800
380415V
480V
600V
Cat. No.
65
65
50
50
50
500V
25
20
690V
10
65
50
25
140U-M5X3
100
100
70
70
70
50
25
13
100
65
35
140U-M6X3
Electronic
Rated
Current
In
Thermal Trip
Ir = In
Magnetic Trip
Im = 510 x In
Cat. No.
300
300
15003000
140U-MTD3-D30
350
350
17503500
140U-MTD3-D35
400
400
20004000
140U-MTD3-D40
450
450
22504500
140U-MTD3-D45
500
500
25005000
140U-MTD3-D50
600
600
30006000
140U-MTD3-D60
700
700
35007000
140U-MTD3-D70
800
800
40008000
140U-MTD3-D80
Rated
Operational
Current
In
800A
4008009
Magnetic Trip
Im = 28 x In
8006400
Protection Type
Cat. No.
400800 A LS
Electronic Trip
Unit
140U-MTL3-D80
400800 A LSI
Electronic Trip 140U-MTH3-D80
Unit
400800 A
LSG Electronic
Trip Unit
140U-MTG3-D80
Rating Plugs
Thermal Trip
In [A]
Cat. No.
Thermal Trip
In [A]
Cat. No.
400
140U-MRP3-D40
700
140U-MRP3-D70
500
140U-MRP3-D50
800
140U-MRP3-D80
600
140U-MRP3-D60
Breaking
Capacity/Interrupting Rating
[kA]7
Rated Operational
Current
In
Thermal Trip
Ir = In
400V
480V
Cat. No.
400V
480V
Cat. No.
300
300
50
50
140U-M5D3-D30
70
65
140U-M6D3-D30
350
350
50
50
140U-M5D3-D35
70
65
140U-M6D3-D35
400
400
50
50
140U-M5D3-D40
70
65
140U-M6D3-D40
450
450
50
50
140U-M5D3-D45
70
65
140U-M6D3-D45
500
500
50
50
140U-M5D3-D50
70
65
140U-M6D3-D50
600
600
50
50
140U-M5D3-D60
70
65
140U-M6D3-D60
700
700
50
50
140U-M5D3-D70
70
65
140U-M6D3-D70
800
800
50
50
140U-M5D3-D80
70
65
140U-M6D3-D80
7 Full ratings are found in the breaker frames table on this page
33
Bulletin 140U
Breaking Capacity/
Interrupting Rating [kA]7
Thermal Trip
Ir = 0.51.0 x In
2008009
Breaking Capacity/
Interrupting Rating [kA]7
Protection
Type
400V
480V
Cat. No.
400V
480V
Cat. No.
LS
50
50
140U-M5L3-D80
70
65
140U-M6L3-D80
LSI
50
50
140U-M5H3-D80
70
65
140U-M6H3-D80
LSG
50
50
140U-M5G3-D80
70
65
140U-M6G3-D80
<ENSpace/>
800
8000
34
380415V
100
70
100
70
500V
70
50
25
13
240V
480V
600V
Cat. No.
100
65
35
140U-M6S3-D80
Bulletin 140U
Mounting Location
Cat. No.
140U-M-EA1
(1) 1a-1b
(2) 1a-1b
Diagram
140U-M-EA2
140U-M-ER1
Auxiliary/Alarm Contact
(AX/AL)
Combination
Combination of auxiliary
contact and alarm
contact
140U-MEA1R1
(1) 1a-1b
(1) 1M (make)-1B (break)
Right Side Only
1224V, 50/60/DC
140U-M-SNJ
110240V AC,
110125V DC
140U-M-SND
380440V AC,
220250V DC
140U-M-SNN
480600V, 50/60 Hz
140U-M-SNB
24V, 50/60 Hz
140U-M-UJ
110127V, 50/60 Hz
140U-M-UD
208240V, 50/60 Hz
140U-M-UA
380500V, 50/60 Hz
140U-M-UB
35
Bulletin 140U
140U-M-FCX04
6 ft (1.8 m) Cable
140U-M-FCX06
10 ft (3.0 m) Cable
140U-M-FCX10
4 ft (1.3 m) Cable
140U-M-FCS04
6 ft (1.8 m) Cable
140U-M-FCS06
10 ft (3.0 m) Cable
140U-M-FCS10
Black Handle
140U-M-RVM12B
Red/Yellow Handle
140U-M-RVM12R
Black Handle
140U-M-RVM21B
Red/Yellow Handle
140U-M-RVM21R
Black Handle
140U-M-NVM12B
Red/Yellow Handle
140U-M-NVM12R
Black Handle
140U-M-NVM21B
Red/Yellow Handle
140U-M-NVM21R
Qty: 1
140U-M-TLC3
Qty: 1
140U-M-TLA3
Qty: 1
140U-M-TLA2
Qty: 1
140U-M-TLA2A
Qty: 1
140U-M-TLC2
Phase Barriers
Provides additional phase clearance when special connections that
extend past the circuit breaker housing are required
Qty: 2
140U-M-PB
Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1
140U-M-PL
140U-M-MHM
Terminal Lugs
Terminal Lugs
Mounting Hardware
(4) M8 - 1 x 35 mm
36
Cat. No.
4 ft (1.3 m) Cable
Bulletin 140U
Line End
2.018
(51.26)
.375 (9.53) Dia. 4-Holes for .312 (7.92) 16 (406.40) x 1.75 (44.45) Large Mounting Screws.
8.302
(210.87)
.500
(12.70)
1.411
(35.84)
Max.
.547
(13.89)
7.677
(195.00)
6.052
(153.72)
On/I
.415
(10.54)
Tripped
0.2
11.500
(292.10)
On/I
On
14.7
C
L
Handle
Pivot
Off
19.2
Off/O
Off/O
14.750
(374.65)
Reset
24.2
16.000
(406.40)
Dim.
B
1.375
(34.93)
Dim.
A
.500
(12.70)
2.750
(69.85)
.531
(13.49)
2.531
(64.29)
4.062
(103.17)
2.750
(69.85)
5.500
(139.70)
4.375
(111.13)
4.250
(107.95)
8.250
(209.55)
Load End
3.250
(82.55)
1.625
(41.28)
1.625
(41.28)
.813
(20.65)
1.874
(47.60)
Breaker Status
Dimension A
Dimension B
On
8.72
(221.49)
9.17
(232.92)
Off
6.72
(170.69)
7.14
(181.36)
Tripped
7.86
(199.64)
8.30
(210.82)
Reset
6.44
(163.58)
6.84
(173.74)
37
Bulletin 140U
Thermal Trip
Ir = 0.51.0 x In
1200
1200
1200
60012009
6001200
60012009
Magnetic Trip
Im = 28 x In
Protection
Type
120010600
120010600
120010600
220240V 380415V
500V
690V
240V
480V
600V
Cat. No.
LS
85
85
50
50
40
20
20
10
65
50
25
140U-N5L3-E12
LS
100
100
70
50
50
25
25
13
100
65
35
140U-N6L3-E12
LSI
100
100
70
50
50
25
25
13
100
65
35
140U-N6H3-E12
LSG
100
100
70
50
50
25
25
13
100
65
35
140U-N6G3-E12
LS
200
100
100
50
65
33
35
18
200
100
50
140U-N0L3-E12
LSI
200
100
100
50
65
33
35
18
200
100
50
140U-N0H3-E12
LSG
200
100
100
50
65
33
35
18
200
100
50
140U-N0G3-E12
Rating Plugs
Rated
Operational
Current
In
600
Cat. No.
Rated
Operational
Current
In
Cat. No.
140U-NRP3-D60
900
140U-NRP3-D90
700
140U-NRP3-D70
1000
140U-NRP3-E10
800
140U-NRP3-D80
1200
140U-NRP3-E12
Magnetic Trip
10 x In
1200
12000
38
380415V
70
50
500V
50
25
25
13
240V
100
480V
65
600V
35
Cat. No.
140U-N6S3-E12
Bulletin 140U
Mounting Location
Cat. No.
140U-N-EA1
(1) 1a-1b
(2) 1a-1b
Diagram
140U-N-EA2
140U-N-ER1
Auxiliary/Alarm Contact
(AX/AL)
Combination
Combination of auxiliary
contact and alarm
contact
Undervoltage Release
(UVT)
Automatically trips
breaker when voltage
falls between preset
value, 3570%
Shunt trip is not available
when undervoltage
release is used
(1) 1a-1b
(1) 1M (make)-1B (break)
140U-NEA1R1
Right side ONLY
1224V, 50/60/DC
140U-N-SNJ
110240V AC,
110125V DC
140U-N-SND
380440V AC,
220250V DC
480600V, 50/60 Hz
140U-N-SNN
Left side ONLY
140U-N-SNB
24V, 50/60 Hz
140U-N-UJ
110127V, 50/60 Hz
140U-N-UD
208240V, 50/60 Hz
140U-N-UA
380500V, 50/60 Hz
140U-N-UB
39
Bulletin 140U
Cat. No.
4 ft. (1.2 m) Cable
140U-N-FCX04
140U-N-FCX06
140U-N-FCX10
Black Handle
140U-N-RM12B
Phase Barriers
Provides additional phase clearance when
special connections that extend past the
circuit breaker housing are required
Qty: 2
140U-N-PB
Padlock Kit
Padlocking Hasp
Lock-OFF only
Qty: 1
140U-N-PL
Motor Operator
Remotely opens, closes, and resets the
circuit breaker
Qty: 1
140U-N-EOPD
Qty: 1
140U-N-EOPA
Motor Operator
Remotely opens, closes, and resets the
circuit breaker
Qty: 1
140U-N-EOPZ
140U-M-MHM
Mounting Hardware
(4) M8 - 1 x 35 mm
40
Bulletin 140U
Cat. No.
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(2) 1500 MCM
(2) 50240 mm2
Description
Qty: 1
140U-N-TLA2
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(3) 3/0400 MCM
(3) 95185 mm2
Qty: 1
140U-N-TLA3
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(4) 4/0500 MCM
(4) 120300 mm2
Qty: 1
140U-N-TLA4
Terminal Lugs
Aluminum Lug
Aluminum or Copper Wire
(3) 500750 MCM
(3) 300400 mm2
Qty: 1
140U-N-TLA3A
Terminal Lugs
Copper Lug
Copper Wire only
(2) 2/0500 MCM
(2) 70240 mm2
Qty: 1
140U-N-TLC2
Terminal Lugs
Copper Lug
Copper Wire only
(3) 3/0500 MCM
(3) 95240 mm2
Qty: 1
140U-N-TLC3
Terminal Lugs
Copper Lug
Copper Wire Only
(4) 3/0400 MCM
(4) 95185 mm2
Qty: 1
140U-N-TLC4
41
Bulletin 140U
Removable T erminal
Cover Must Be in
Place While in Service
1.157(29.388)
.532(13.513)
.062(1.575)
Line End
3.236
(82.194)
Trough for
Attachment Lead
.250 R
(6.350)R
7.000 (177.774)
9.250 (234.950)
14.750(374.650)
8.625(219.075)
115.00 (292.075)
11.431
(290.348)
.125 X .750
(3.175 X 19.050)
Slots for
Attachment Leads
.062 R
(1.575) R
.094 R
(2.388) R
.297
(7.544)
3.850R
212
ON/I
ON
.353
(6.331)
02
TRIPPED
.750 (19.050)
.375 (9.525)
OFF/O
.188R
(4.762) R
2.511
(63.786)
1.375
(34.925)
2.750
(69.850)
2.344
3.187
(59.541)
(80.950)
6.375
(161.925)
4.124
(104.750)
.062
(1.588)
R
1.095(27.813)
3.344(84.938)
5.188(131.769)
5.500(139.687)
Dimensions
2.750 Ref.
(69.850) Ref.
2.000
(50.800)
.781 (19.844)
.062
(1.588)
R
.062 (1.575)
.532 (13.513)
5.248(133.293)
1.688
(42.863)
1.562
(39.687)
Load End
Removable Terminal
Cover Must Be in
Place While in Service
3.375
(85.725)
2.000
(50.800)
1.000
(25.400)
Breaker Status
6.000(152.400)
On
7.90 (200.66)
8.30 (210.82)
Tripped
6.50 (165.10)
6.90 (175.26)
Off
5.70 (144.78)
6.10 (154.94)
Reset
5.60 (142.24)
6.00 (152.40)
7.132 (181.146)
3.906
(99.187)
On
Off
Reset
1.500 Ref
(38.100) Ref
3.819
(96.723)
4.875
(123.799)
.062
(1.575)
42
1.034
(33.281)
Handle
Pivot
8.250
(209.550)
2.982
(75.743)
B A
3.808
(96.723)
2.798
(71.057)
.375
(9.525)
RESET
1.500
(38.100)
.312 R
(7.925) R
132OFF
152
.946
(24.022)
CL Push To Trip
16.000 (406.401)
CL Handle
2.493
(63.792)
6.375 Ref
(161.925) Ref
Bulletin 140U
3-Pole Breaker
Mounting Location
Left side only
2-Pole
3-Pole
(1) AX
-A
-A
Suffix
Auxiliary and
Alarm
Contacts
Suffix
- G
- P
- H
- Q
- R
Suffix
Suffix
(1) AX
-A
(2) AX
-B
- J
(1) AL
-D
- L
- T
- N
- V
(1) AX + (1)
AL
-F
24
AC,
50/60 Hz
Voltage [V]
DC
Voltage [V]
1224
110240
380600
AC,
50/60 Hz
Voltage [V]
1224
110125
DC
Allen-Bradley distributor.
43