Sunteți pe pagina 1din 14

opticalCON Field Assembly

TOOLS & ACCESSORIES

CABLE

MEASUREMENT

v1

opticalCON Field Assembly


Tools and Accessories
Pre-requirements Certification is valid for 2 years and can be evaluated after that period. In case of assembly quality issues, Field Assembly certification may be suspended. Cable requirements Neutrik opticalCON connectors may only be assembled with certified cables. Neutrik certified cables are listed below. Additional cable certifications may be requested from customers with Field Assembly certification. Minimum quantity on strain relief kits will be expected if existing strain reliefs do not match with custom requested cables. Type NO2MX-R-KIT-FA NO2SX-R-KIT-FA Description opticalCON DUO; ruthenium plating; multimode PC, single mode PC; strain relief KIT to be ordered separately; includes 2x field assembly LC

Ruthenium plating, MM PC Ruthenium plating, SM PC

NOSR-2C-FA NOSR-S1-FA NOSR-S5-FA NO2MLC-FA

Strain relief kit for 2-ch cables Strain relief kit for SMPTE cables Strain relief kit for Low voltage cables

Cable retention, crimp ferrules, boot (see cable table below). Cable retention, crimp ferrules, boot, pins (see cable table below). Cable retention, crimp ferrules, boot, pins (see cable table below). opticalCON field assembly LC; multimode PC

NO2SLC-FA

opticalCON field assembly LC; single-mode PC

CASOPTICALCON-FA

opticalCON Field Assembly case for selftermination.

v1

opticalCON Field Assembly


Tools and Accessories
HX-R-BNC Crimp tool for cable retention, suitable dies DIE-BNC-R-*

DIE-R-OPT* DIE-R-OPT3A DIE-R-OPT3 DIE-R-OPT4 DIE-R-OPT5

HEX HEX SQUARE 6.47 5.41 6.47 5.41 9.73 2.54 1.6 7.36 8.23

HTOPT-S1

HTOPT-S2

Crimp dies to be used with HX-RBNC crimp tool only. DIE-R-OPT3A offers combined strain relief assembly for low quantities. opticalCON assembly fixture for cable retention, use together with crimping tool HX-R-BNC plus appropriate die opticalCON strain relief assembly fixture, use for large quantity production opticalCON assembly fixture for opticalCON field termination, contains fixture, user manual and technical info. Cable stripper for HYBRID cables

HTOPT-S3

HTOPT-CS

v1

opticalCON Field Assembly


Tools and Accessories
CAS-FOCD opticalCON Fiber Optic Cleaning Device - contains lint-free wipes, dry cleaning sticks, fiber connector cleaner, fiberscope and adapter

FOCD-CF (refill accessory CAS-FOCD)

Fiber Optic Cleaning Devices Cleaning Fluid

FOCD-DC250

Dry cleaner 2.5mm for SC, FC,ST

FOCD-DC125

Dry cleaner 2.25mm for LC and MU

FOCD-DW

Lint-free dry wipes for fiber cleaning

CAS-FOMD

Measurement kit for fast system connectivity check - contains power meter SM, attenuator, 2.5mm/1.25mm adapter

FOMD-TC-MM850 FOMD-TC-SM1310 FOMD-TC-SM1550

Transceiver 850nm multimode Transceiver 1310nm single-mode Transceiver 1550nm single-mode)

FOMD-FM-MM FOMD-FM-SM

Fiber meter multimode Fiber meter single-mode 3 digit

v1

opticalCON Field Assembly


Tools and Accessories
Cable manufacturer order # OCC OC0002036 OCC OC0002401 OCC OC0002037 OCC OC0002402 BELDEN 7804C Belden BELDEN 7804R DUO lowvoltage single-mode hybrid OCC OC0002432 OCC OCC OC0002796 BELDEN GMTT204 50/125 BELDEN GMTTA04 E9 Belden Black shiny Gray matt Gray matt Gray matt

Fiber cable type DUO multimode

Cable manufacturer

Cable jacket Gray matt Black shiny Gray matt Black shiny Gray matt

Cable OD 5mm 0.20

DIE

Suitable connector kit

Related strain relief kit

OCC

OPT3

NO2MX-R-KIT-FA

NOSR-2C-FA

DUO singlemode

OCC

5mm 0.20

OPT3

NO2SX-R-KIT-FA

NOSR-2C-FA

DUO * SMPTE single-mode

9.2mm 0.36

OPT4

NO2SX-R-KIT

NOSR-S1-FA

NO2SX-S5-FA 7.3mm 0.30 OPT5 NO2SX-R-KIT-FA

QUAD multimode

5mm 0.20

OPT3

NO4MX-R-KIT-FA

NOSR-4C-FA

QUAD single-mode

Belden

Gray matt

5mm 0.20

OPT3

NO4SX-R-KIT-FA

NOSR-4C-FA

*Not compatible to SMPTE 344M standard. Suitable for indoor (studio) camera links considering specific conditions acc. to IEC 60664-1 like pollution degree 1, over voltage category 1 and rated voltage (max 250Vac / 400Vdc).

Contact information - cable manufacturer: OCC- optical cable corporation Concourse Drive 5290 11967 Roanoke, VA 24022-1967 USA www.occfiber.com Belden Europe Edisonstraat 9 5900 AA Venlo The Netherlands www.belden.com

v1

opticalCON Field Assembly


Cable Datasheets
OC-0002036 OC-0002401

Item number Number of fibers Fiber type Core diameter Cladding Diameter Primary coating diameter Secondary buffer diameter Numerical aperture Proof test level Wavelength Attenuation Bandwidth Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature

OC-0002036 2 multimode 50 um 125 um 500 um 900 um 0.20 100 kpsi 850 nm/1300 nm 3.0 dB/km (850 nm); 1.0 dB/km (1300 nm) 500 MHz/km 23 kg/km 5.0 mm

OC-0002401 2 multimode 50 um 125 um 500 um 900 um 0.20 100 kpsi 850 nm/ 1300 nm 3.0 dB/km (850 nm); 1.0 dB/km (1300 nm) 500 MHz/km 23 kg/km 5.0 mm

1800N 8.0 cm

1800N 8.0 cm

600N 4.0 cm 200 impacts (EIA/TIA-455-25 Military Req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C

600N 4.0 cm 200 impacts (EIA/TIA-455-25 Military Req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C

Cable surface

V jacket

C - jacket

v1

opticalCON Field Assembly


Cable Datasheets
OC-0002037 OC-0002402

Item number Number of fibers Fiber type Core diameter Cladding Diameter Primary coating diameter Secondary buffer diameter Numerical aperture Proof test level Wavelength Attenuation Nominal zero dispersion slope Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature

OC-0002037 2 single-mode 8.3 um 125 um 500 um 900 um 0.13 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5dB/km (1550 nm) 0.092 ps/(nm2-km) 23 kg/km 5.0 mm

OC-0002402 2 single-mode 8.3 um 125 um 500 um 900 um 0.13 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5dB/km (1550 nm) 0.092 ps/(nm2-km) 23 kg/km 5.0 mm

1800 N 8.0 cm

1800 N 8.0 cm

600 N 4.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C

600 N 4.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C

Cable surface

V jacket

C jacket

v1

opticalCON Field Assembly


Cable Datasheets
Belden 7804C

Item number Number of fibers Fiber Type Core diameter Cladding diameter Fiber buffer tube diameter Wavelength Attenuation Cable weight Cable diameter Min. bend radius

Belden 7804C 2 Single-mode 9.5 um 125 um 900 um 1310 nm 0.45 dB/km 121 kg/m 9.2 mm 63.5mm

Number of conductors Conductor diameter Conductor insulation diameter Conductor DC resistance

4 0.6 mm (AWG 24)/ 1.49 mm (AWG 16) 1.27 mm (AWG 24)/ 2.36 mm (AWG 16) AWG 24: 76.4 ohms/1000m AWG 16: 14.1 ohms/1000m

Operating temperature Cable surface

-30 to +60 C C C-jacket

v1

opticalCON Field Assembly


Cable Datasheets
Belden 7804R

Item number Number of fibers Fiber Type Core diameter Cladding diameter Fiber buffer tube diameter Wavelength Attenuation Cable weight Cable diameter Min. bend radius

Belden 7804C 2 Single-mode 9.5 um 125 um 900 um 1310 nm 0.45 dB/km 121 kg/m 9.2 mm 63.5mm

Number of conductors Nominal core OD Conductor DC resistance

4 1.27 mm (AWG 24)/ 2.36 mm (AWG 16) AWG 24: 76.4 ohms/1000m AWG 16: 28.9 ohms/1000m

Operating temperature Cable surface

-30 to +60 C C C-jacket

v1

opticalCON Field Assembly


Cable Datasheets

OCC OC-0002432 OCC OC-0002796

Item number Number of fibers Fiber type Cladding Diameter Primary coating diameter Secondary buffer diameter Proof test level Wavelength Attenuation

OC-0002032 2 single-mode 125 um 245 um 900 um 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5 dB/km (1550 nm) 65 kg/km 7.3 mm

OC-0002796 2 single-mode 125 um 245 um 900 um 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5 dB/km (1550 nm) 65 kg/km 7.3 mm

Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature

2200 N 12.0 cm

2200 N 12.0 cm

500 N 8.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -40 to +85 C C -55 to +85 C C

500 N 8.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -40 to +85 C C -55 to +85 C C

Cable surface

V jacket

C - jacket

v1

opticalCON Field Assembly


Cable Datasheets
Belden GMTT204 50/125 Belden GMTTA04 E9

Item number Number of fibers Fiber type Cladding Diameter Secondary buffer diameter Wavelength Attenuation

Belden GMTT204 50/125 4 multimode 125 um 900 um 1300 nm/ 850 nm 2.3 dB/km (850 nm) 0.6 dB/km (1300 nm) 31 kg/km 5.8 mm

Belden GMTTA04 E9 4 single-mode 125 um 900 um 1300 nm/ 850 nm 0.35 dB/km (1310 nm) 0.21 dB/km (1550 nm) 31 kg/km 5.8 mm

Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Crush resistance Operation temperature Storage temperature

1200 N 10 cm

1200 N 10 cm

800 N 10 cm 4000 N/m -55 to +85 C C -70 to +85 C C

800 N 10 cm 4000 N/m -55 to +85 C C -70 to +85 C C

Cable surface

black matt

black matt

v1

opticalCON Field Assembly


Pin Assignment
The pin assignments are in-house standards. The solder cups in the opticalCON connector are designed for certified cables (see cable matrix). To reduce faults use following pin assignment for each cable.

Belden 7804C: Wire color White Red Gray White Pin number 1 2 3 4

OCC OC-0002432 OCC OC-0002796 Wire color Black/White White Pin number 1 4

v1

opticalCON Field Assembly


Pin Assignment
Attention: The following step shows the measurement system in our in-house production from Neutrik AG.

Single-mode
Zeroing

Measurement

Multimode
Zeroing
LAUNCH FIBRE 500 m / 50 m FC-ADAPTER NEUTRIK NO2-4FD[1]
MEASURING CABLE

FC-ADAPTER

MEASURING CABLE

TAIL FIBRE 100 m / 50 m

MM

SM

OUT LIGHT SOURCE POWER METER

IN

Measurement
LAUNCH FIBRE 500 m / 50 m FC-ADAPTER NEUTRIK NO2-4FD[1] NEUTRIK NO2-4FD[2] FC-ADAPTER
MEASURING CABLE MEASURING CABLE

TAIL FIBRE 100 m / 50 m

DUT NEUTRIK NKO2M-***

MM

SM

OUT LIGHT SOURCE POWER METER

IN

v1

opticalCON Field Assembly


Contact Info
Liechtenstein (Headquarters) NEUTRIK AG, Im alten Riet 143, 9494 Schaan T +423 237 24 24, F +423 232 53 93, neutrik@neutrik.com Germany/Netherlands/Denmark/Austria Neutrik Vertriebs GmbH, Felix-Wankel-Strasse 1, 85221 Dachau T +49 8131 28 08 90, info@neutrik.de Great Britain Neutrik (UK) Ltd., Westridge Business Park, Cothey Way Ryde, Isle of Wight PO33 1 QT T +44 1983 811 441, sales@neutrik.co.uk France Neutrik France SARL, Rue du Parchamp 13, 92100 Boulogne-Billancourt T +33 1 41 31 67 50, info@neutrik.fr USA Neutrik USA Inc., 195 Lehigh Avenue, Lakewood, NJ 08701-4527 T +1 732 901 94 88, info@neutrikusa.com Japan Neutrik Limited, Yusen-Higashinihonbashi-Ekimae Bldg., 3-7-19 Higashinihonbashi, Chuo-ku, Tokyo 103 T +81 3 3663 47 33, mail@neutrik.co.jp Hong Kong Neutrik Hong Kong LTD., Workshop 14, 16 Floor, Wah Wai Centre Nr. 38-40 Au Pui Wan Street, Shatin, New Territories T +852 2687 6055, neutrik@neutrik.com.hk China Ningbo Neutrik Electronics Co., Ltd., Shiqi Street, Yinxian Road West Fengjia Villiage, Yinzhou Area, Ningbo, Zhejiang; 315153 T +86 574 88250488 800, neutrik@neutrik.com.cn