Product Sheet

DCG Series DC Generator Sets


Mechrons DCG line of generator sets is designed for use in DC prime, standby and hybridrenewable applications. DCG generators ensure continuous operation of your equipment, providing automatic start to charge station batteries in the event of utility or rectifier failure or low station batteries. DCG generators feature advanced microprocessor controls and available remote monitoring and control capability. DCG Series Generator Sets are available with weather-resistant enclosures for outdoor installation.

Mechron Power Systems 2437 Kaladar Avenue Ottawa, Ontario Canada K1V 8B9 Tel: (613) 733-3855 Fax: (613) 733-8197 www.mechron.com A Division of Toromont Industries Ltd.

Benefits:
Simple, redundant battery backup designed for ease of installation and maintenance DC output reduces costs and space requirements and increases efficiency and reliability over AC solutions. The DC output connects directly to the station battery, bypassing rectifiers; no transfer switch is required Seamless integration with hybrid-renewable systems, including solar, wind and Mechrons Cycle Charge system Automatic operation based on defined conditions including loss of AC utility power and low station battery voltage ensures uninterrupted DC power availability Available in 4.5 or 7 kW, 24 or 48 VDC, positive or negative ground Available in diesel, natural gas and liquid propane gas versions Allows for smaller capacity station battery Configurable shutdowns and alarms via PC interface Remote monitoring, control and configuration via GC View software or GC WebView web browser interface

Product Sheet

Features:
Automatic start on loss of AC utility power or low station battery voltage Engine run hourmeter Discrete Outputs: Common Alarm, AC Available, Engine Running Shutdowns (with indication) Low Oil Pressure High Engine Temperature Overspeed Underspeed Overvoltage No speed signal Local Run / Off / Auto settings Discrete input for remote Start / Stop / Reset RS232 and Ethernet communications ports for remote monitoring and control and diagnostic interface GC View Software: Allows complete remote monitoring, control and configuration of alarms, shutdowns and settings GC WebView: Built-in web server for HTTP web-based monitoring

Mechron Power Systems 2437 Kaladar Avenue Ottawa, Ontario Canada K1V 8B9 Tel: (613) 733-3855 Fax: (613) 733-8197 www.mechron.com A Division of Toromont Industries Ltd.

Options:
Outdoor enclosure Wind, snow, ice and rain resistant Forklift pockets Lockable, with tamper resistant hardware Available height extension legs up to 1m (39) Available sound-attenuation 67 dBA @ 25 feet (7.6m) Cold weather package Extended maintenance interval (1,000 hours) Extended run 48 hour fuel tank (150L / 39.6 US gal) Single point lift (without enclosure) Start battery and on-board battery charger DC output circuit breaker Dial-up Modem Package Automatic dial out pager notification on warning or fault Trend and Report Software for GC View Programmable HMI operator interface for on-site visual display of operating parameters, alarms, shutdowns and settings and control of ancillary site functions

Product Sheet

GC Series Controllers:
DCG Series Generator Sets include Mechrons GC 2000 controller. The GC 2000 features a full HMI interface, providing comprehensive controls and safety shutdowns, including full engine and alternator field control, automatic start, cycling and remote control and monitoring capability.

SPECIFICATIONS
Mechron Power Systems 2437 Kaladar Avenue Ottawa, Ontario Canada K1V 8B9 Tel: (613) 733-3855 Fax: (613) 733-8197 www.mechron.com A Division of Toromont Industries Ltd.
Power Ratings Output Voltages Engine Types Voltage Regulation Ripple Communications Discrete Outputs 4.5 - 7 kW 24 or 48 VDC, positive or negative ground Liquid Cooled - Kubota +/-1% 500 mV Protocols: TCP/IP (HTTP, custom), Modbus ASCII Connectors: RS232-DB9, Ethernet RJ45 Common Alarm AC Available Engine Running Low Oil Pressure High Engine Temperature Overspeed / Underspeed Overvoltage No speed signal -40C to +45C (-40F to 113F) w/cold start package Without Enclosure: 80 dBA @ 25 feet (7.6m) 12 V with on-board charger

Shutdowns

Operating Temperature Acoustic Noise Starting System

MODELS
Specification Without Enclosure Power Output Voltage Output Fuel Types Engine Fuel Consumption 75% load Weight (Dry) Dimensions (LxWxH) Enclosure Dimensions (LxWxH) Weight Acoustic Noise 53 x 30 x 37" / 135cm x 76cm x 94cm 350 lb / 159 kg With Enclosure: 67 dBA @ 25 feet (7.6m) Diesel Kubota Z482 0.40 gal/h 1.5 L/h 267 lb / 121 kg 4.5kW 24 or 48V LPG / NG Kubota DF752 29 / 66 ft /h 290 lb / 132 kg
3

DCG4500

DCG7000 7kW 24 or 48V Diesel Kubota D722 0.63 gal/h 2.4 L/h 354 lb / 161 kg LPG / NG Kubota DF752 44 / 102 ft3/h 354 lb / 161 kg

35 x 25.5 x 30" 89 cm x 65 cm x 76 cm

39 x 25.5 x 30" 99 cm x 65 cm x 76 cm

Product Sheet

DIMENSIONS

Mechron Power Systems 2437 Kaladar Avenue Ottawa, Ontario Canada K1V 8B9 Tel: (613) 733-3855 Fax: (613) 733-8197 www.mechron.com A Division of Toromont Industries Ltd.