ORDER WIRE EQUIPMENT

EOW 300 ( Surpass hiT - 1 / 4 / 16 )

User Guide

N56715450104

SIEMENS

ORDER WIRE EQUIPMENT EOW 300


User Guide

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A0-1

CONTENTS

Order Wire Equipment (EOW).A0-1 to A2-19


CONTENTS A0-2

1. GENERAL ...............................................................................................................A1-1 to A1-9 1.1 - Product overview 1.2 - Operating features 1.2.1 - Call management rules 1.2.2 - DMTF sequences 1.2.3 - LEDs 1.2.4 - Tone signals 1.2.5 - Reset button 1.3 - Technical specifications 1.3.1 - V.11 interface - DIGITAL PORTS (#1, #2, #3) 1.3.2 - Z interface - TELSET 1.3.3 - Power supply - PWR 1.3.4 - LOOPS 1.3.5 - Environmental conditions
Figures Figure 1.1 - Overview of the EOW300

A1-1 A1-3 A1-3 A1-4 A1-6 A1-7 A1-7 A1-8 A1-8 A1-9 A1-9 A1-9 A1-9

2. INSTALLATION - COMMISSIONING...................................................................A2-1 to A2-11 2.1 - Installation 2.2 - External ports / connections A2-1 A2-3

2.3.1 - Z interface configuration 2.3.2 - Network configurations 2.3.3.1 - Linear networks 2.3.3.2 - Ring networks 2.4 - Commissioning 2.5 - Operation
Figures Figure 2.1 - Mechanical features Figure 2.2 - EOW300 - Different mounting modes Figure 2.3 - EOW300 / External ports - connections Figure 2.4 - EOW 300 Association Figure 2.5 - Typical configuration

A2-8 A2-9 A2-10 A2-10 A2-11 A2-11

User Guide - N56715450104 Page A-0-2 Reproduction and communication not allowed without written authorization from Siemens AG

1 - GENERAL

1. GENERAL 1.1 - Product overview


EOW300 telephone engineering order wire units are deployed along a link or in a transmission network to allow communication between operators for installation or maintenance purposes. The telephones that are connected to the EOW300 are standard off-the-shelf telephones and compatible with the switched network. They must be set to dual tone multifrequency mode (DTMF). The EOW300 units communicate with one another over 64 kbit/s digital channels available on the transmission equipment (optical fibres, microwave links etc). Each EOW300 acts as a digital repeater/multiplexer. All data from one channel (V.11 or Z) is forwarded to the others to broadcast the information throughout the network. Each EOW300 comprises (see Figure 1.1): three 64 kbit/s interfaces (V.11), a local telephone interface (Z interface), LEDs, signalling loop extension contacts (dry loops), a Reset button, a -48 Vdc power supply connector, an external power supply connector. Calls set up via the EOW300 units have the following general features: Calls can be made to a specific telephone, a group of telephones or to all telephones. The EOW300 units provide no confidentiality; any user can join in a conversation that is already set up. The equipment in the EOW300 network can be configured as a "closed loop" (ring networks) provided that one of the EOW300 units in the ring is declared as the "ring master".

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A1-1

1 - GENERAL

Equipment FAULT LED Engaged LED

Remote FAULT LED

ST A FAU LTS

TUS

LOOPS

V11 digital ports #1, #2, #3

Reset

Master LED

Power supply (PWR)

Power supply (Jack)

Power LED (ON)

Telephone socket (TELSET)

V11 Status ports #1, #2, #3

Figure 1.1 - Overview of the EOW300

User Guide - N56715450104 Page A1-2 Reproduction and communication not allowed without written authorization from Siemens AG

1 - GENERAL

1.2 - Operating features 1.2.1 - Call management rules


The EOW300 operates as follows: In general, a high-pitched beep in the handset signals that the dialled DTMF sequence has been recognized and accepted whereas a low pitched beep indicates that the sequence has not been recognized. During a conversation, two distinctive beeps indicate that a user has lifted or replaced his handset. Calls can be made to a single telephone, a group of telephones or to all the telephones in the network. Calls to a single telephone are made in the usual way by lifting the handset and dialling the number of the required telephone (three digit number). Dialling and its effects (ringing) can be cancelled by hanging up the calling phone. If no call is in progress when the handset is lifted, the EOW300 responds with a dial tone. When the number has been dialled, the local EOW300 responds with a routing tone followed by the ringing tone. Note: For a group call or general call, the routing and ringing tones do not exist. A high pitched beep tells the user that the call request has been accepted. When conversation begins, it cuts out any tone signals to make way for the speech signals. If one handset is lifted, the lifting of a second handset connects the two users, regardless of whether a number has been dialled. If a user lifts his handset when a call is in progress, he is automatically connected to that call. A call ends when all the phones have been hung up. Any DTMF sequence can be dialled when a conversation is already in progress. During conversation, the user can isolate himself from the network by pressing "R" (or with an on-hook pulse of between 50 and 350 ms) to dial a DTMF sequence for example. The same "R" button is used to return to conversation mode. When a telephone is engaged in a call, it does not ring if its number is dialled. It is possible to switch to programming mode at any time. This is for setting up the local EOW300 (assigning the telephone number, group number etc). A self-call function is used to test the local EOW300 (checking the telephone number and the ringing and tone functions). The telephone is disconnected from the EOW300 communication network during this test.

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A1-3

1 - GENERAL

1.2.2 - DTMF sequences


The DTMF sequences for using and programming the equipment are listed below:

- DTMF using Sequences


#, on-hook or Reset sequence. This is for cancelling a DTMF call sequence when entering numbers. ### within three seconds, remote on-hook sequence for telephones off-hook. This works by muting any phone that is off the hook and generating noise. The EOW300 concerned transmits a busy tone in the handset and disconnects the digital summing of the speech signals over the Z interface in both directions. Note: - This mode does not adversely affect telephones that are on the hook. - To end mute mode, simply replace the handset. - Any handset that has been the only one off-hook on the line for more than 10 minutes is automatically muted. *** within three seconds, general call sequence This rings all the phones in the network at the same time. Note: No routing or ringing tones. A high-pitched beep indicates that the dialled sequence has been accepted.

*N within three seconds, group call sequence. N represents a digit from 0 to 9. Note: No routing or ringing tones. A high-pitched beep indicates that the dialled sequence has been accepted.

NNN, individual call sequence, N representing a digit from 0 to 9. Note: For a self-call, dialling your own number generates a busy tone and the telephone rings when it has been hung up. The EOW300 self-call procedure ends the next time the handset is lifted.

** within three seconds, sequence for switching to programming mode. This is for setting up the EOW300. In this mode, the unit disconnects the sound bridge between the Z interface and the V.11 interfaces. This sequence can be dialled at any time. The EOW300 confirms the transition to this mode with six short 440 Hz beeps in the handset. This signal is repeated approximately every three seconds. Simply hang up the handset to exit this mode.

User Guide - N56715450104 Page A1-4 Reproduction and communication not allowed without written authorization from Siemens AG

1 - GENERAL

DTMF programming sequences:


*1NNN, telephone number programming sequence. N represents a digit from 0 to 9. *2N, group number programming sequence. N represents a digit from 0 to 9. *3CCC, programming sequence for activating each V.11 interface. C is either 0 (port OFF), or 1 (port ON). The first, second or third C respectively selects or deselects the first, second or third port. *0*0, network reset sequence. This remotely reboots all the network units and the local unit after one second. It's necessary to wait for a low-pitched beep between the two *0 sequences for the command to take effect, otherwise the operation must be reordered.

Note :

- All the parameters configured during programming mode (telephone number, group number, port selection) are saved in non volatile memory.

Important:

Default configuration (factory settings).

Parameter Telephone number Group number Active ports

Default setting 000 0 1, 2 and 3

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A1-5

1 - GENERAL

1.2.3 - LEDs
LED on Colour Green Off On engaged Green Off Blinking On equipment Red Off On remote Red Off On port #1 Yellow Off Blinking On port #2 Yellow Off Blinking On port #3 Yellow Off Blinking On master Yellow Off Blinking On State : Equipment not powered up : Equipment powered up : Telephone on hook and no call in progress : Telephone on hook and call in progress : Telephone off hook : No faults : DSP or power supply malfunction : No faults : Fault on one of the V.11 channels or "master" mode fault. : Channel 1 inactive : No fault on channel 1 : Fault on channel 1 : Channel 2 inactive : No fault on channel 2 : Channel 2 fault : Channel 3 inactive : No fault on channel 3 : Channel 3 fault : Equipment in slave mode : Equipment in master mode : Equipment in master mode and break in the ring detected

LED table

User Guide - N56715450104 Page A1-6 Reproduction and communication not allowed without written authorization from Siemens AG

1 - GENERAL

1.2.4 - Tone signals


Description Dial tone Routing tone Ringing tone Busy tone Programming mode Failure signal (DTMF sequence not recognized) Acknowledgement signal (DTMF sequence recognized) Off-hook signal On-hook signal Continuous 440 Hz signal 440 HZ signal for 50 ms and silence for 50 ms. 440 Hz signal for 1.5 s then silence for 3.5 s 440 Hz signal for 500 ms then silence for 500 ms. 440 Hz signal for 250 ms then silence for 125 ms. Sequence repeated six times followed by silence for 750 ms 220 Hz signal for 500 ms (low-pitched beep) 880 Hz signal for 500 ms (high-pitched beep) 880 Hz signal for 250 ms then 660 Hz signal for 250 ms 660 Hz signal for 250 ms then 880 Hz signal for 250 ms

Tone table

1.2.5 - Reset button


Pressing the Reset button reboots the DSP on the EOW300 board. The unit's own settings (telephone and group numbers, ports in use etc) are then automatically reloaded from EEPROM.

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A1-7

1 - GENERAL

1.3 - Technical specifications 1.3.1 - V.11 interface - DIGITAL PORTS (#1, #2, #3)
Bit rate: Synchronization clocks (64 kHz and 8 kHz) : Polarity of the 64 kHz synchronization clocks: Frame sync signal Electrical levels: Frame sync quality: Timing diagrams:
64 kHz Synchronization clock OR

64 kbit/s codirectional and contradirectional in master or slave mode Option of rising or falling edge (no adjustment on the 8 kHz synchronization clock) internal or external RS-422 Usable up to an error rate of 10-3

8 kHz Synchronization clock

Data B7 B8 B1 B2 B3 B4

An EOW300 can be linked to: Transmission equipment via two V.11 ports (any two) for communication in both East and West directions. Transmission equipment via a single V.11 port (any one) for communication in one direction only (East or West). One or more items of equipment (EOW300 or transmission equipment) via one or more V.11 ports (free choice).

User Guide - N56715450104 Page A1-8 Reproduction and communication not allowed without written authorization from Siemens AG

1 - GENERAL

1.3.2 - Z interface - TELSET


The Z interface has the following features: Number of wires: Balancing and input impedance: Frequency band: Relative input and output levels: 2 600 300 Hz - 3400 Hz Input: 0 dB, +3 dB Output: -1 dB, -4 dB, -7 dB, -10 dB, -13 dB Selected by switch DTMF

Dialling type:

1.3.3 - Power supply - PWR


The EOW300 is powered by a single voltage with the following characteristics: Voltage between -20 Vdc and -72 Vdc Consumption <7W

The EOW300 may be powered either via the 25-way HE 5 connector or the jack connector.

1.3.4 - LOOPS
The "LOOPS" connector comprises the loop extension contacts for the "equipment" and "remote" LEDs. These are dry loops. Fault "equipment" State not declared declared "remote" not declared declared Loop Contact closed between pins 6 and 3 Contact closed between pins 6 and 2 Contact closed between pins 8 and 4 Contact closed between pins 8 and 5

1.3.5 - Environmental conditions


Storage temperature: Operating temperature: Relative humidity in operation: -40 C to +70 C -10C to +55 C < 85 %

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A1-9

2 - INSTALLATION - COMMISSIONING

2. INSTALLATION - COMMISSIONING 2.1 - Installation


The EOW300 is housed in a 1U module that can be adapted width-wise to 19" and metric formats. Check that the unit's position in the frame does not prevent heat dissipation from other equipment. The earth connection is at the rear of the module.

Top view

ST AT FA UL TS

US

EOW300 Equipment Fixing brackets

ST AT FA UL TS

US

Fixing brackets

Figure 2.1- Mechanical features


Distribution of the interfaces:

Position Front

Interface Port 1 (V.11) - HE 5 connector, 15-way Port 2 (V.11) - HE 5 connector, 15-way Port 3 (V.11) - HE 5 connector, 15-way Telephone port (Z interface) - RJ11 connector 8 LEDs (on, engaged, FAULT equipment, FAULT remote, STATUS port #1,#2,#3 master) RESET button (recessed) Loops - HE 5 connector, 9-way 48 V power supply - HE 5, 25-way External power supply - Jack

Rear

The EOW300 can be installed in 19" racks or in ETSI racks (see Figure 2.2) The unit is attached to the rack via the two brackets on the unit as shown in Figure 2. These brackets are secured to the rack by four screws.

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 PageA2-1

2 - INSTALLATION - COMMISSIONING

EOW 300 19" unit fixing for type 80 rack

ST A FAU L TS

TU S

EOW 300 19" unit fixing for type M3 rack

ST A FAU L TS

TU S

Figure 2.2- EOW300 - Different fixings

User Guide - N56715450104 Page A2-2 Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING

2.2 - External ports / connections

"master" LED
ST AT FA U LT S US

PWR - 20 / - 72VDC
13 25 1 14

"reset" button

1 : N48V2 2 : N48V2 3 : N48V1 4 : N48V1 5 : NC 6 : NC 7 : NC 8 : NC 9 : OB 10 : OB 11 : GND 12 : NC 13 : NC

14 : N48V2 15 : NC 16 : N48V1 17 : NC 18 : NC 19 : NC 20 : NC 21 : NC 22 : OB 23 : OB 24 : GND 25 : GND

LOOPS
5 9 1 6

1 : NC 2 : R_DF_EQUIP 3 : T_DF_EQUIP 4 : R_DF_V11 5 : T_DF_V11

6 : C_DF_EQUIP 7 : NC 8 : C_DF_V11 9 : NC

ON ON +48V

V11 DIGITAL PORTS #3


8 15 9 1

TELSET
Contact 1 Contact 6

1 : H8_EM_3N 2 : H8_EM_3P 3 : H8_REC_3N 4 : RX_DATA_3P 5 : RX_DATA_3N 6 : H8_REC_3P 7 : GND 8 : TX_DATA_3P

9 : TX_DATA_3N 10 : H64_EM_3P 11 : H64_EM_3N 12 : H64_REC_3P 13 : H64_REC_3N 14 : GND 15 : NC

1 : NC 2 : NC 3 : LA

4 : LB 5 : NC 6 : NC

#2
8 15 9 1

"engaged" LED

"equipment" LED

1 : H8_EM_2N 2 : H8_EM_2P 3 : H8_REC_2N 4 : RX_DATA_2P 5 : RX_DATA_2N 6 : H8_REC_2P 7 : GND 8 : TX_DATA_2P

9 : TX_DATA_2N 10 : H64_EM_2P 11 : H64_EM_2N 12 : H64_REC_2P 13 : H64_REC_2N 14 : GND 15 : NC

FAULTS
"remote" LED

#1
8 15 9 1

"port # 1" LED

"port # 2" LED

STATUS

1 : H8_EM_1N 2 : H8_EM_1P 3 : H8_REC_1N 4 : RX_DATA_1P 5 : RX_DATA_1N 6 : H8_REC_1P 7 : GND 8 : TX_DATA_1P

9 : TX_DATA_1N 10 : H64_EM_1P 11 : H64_EM_1N 12 : H64_REC_1P 13 : H64_REC_1N 14 : GND 15 : NC

"port # 3" LED (NC : Not Connected)

Figure 2.3 - EOW 300 / External ports - connections


User Guide - N56715450104 PageA2-3

Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING Connector pin-outs:


Connector PWR (HE5, 25-way) male Pin 1 2 3 4 9 10 11 14 16 22 23 24 PWR (Jack) TELSET (RJ11) #1 (HE5, 15-way) female 25 central external 3 4 1 Name N48V2 N48V2 N48V1 N48V1 OB OB GND N48V2 N48V1 OB OB GND GND - 48V GND LA LB H8_EM_1N - 48 V DC - 48 V DC - 48 V DC - 48 V DC OB OB Ground - 48 V DC - 48 V DC OB OB Ground Ground - 48V DC OB Telephone Telephone 8 kHz sync clock - Transmit Description

2 3 4 5 6 7 8 9 10 11 12 13 14

H8_EM_1P H8_REC_1N RX_DATA_1P RX_DATA_1N H8_REC_1P GND TX_DATA_1P TX_DATA_1N H64_EM_1P H64_EM_1N H64_REC_1P H64_REC_1N GND

8 kHz sync clock - Transmit 8 kHz sync clock - Receive Data In - Receive Data In - Receive 8 kHz sync clock - Receive Ground Data Out - Transmit Data Out - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Receive 64 kHz sync clock - Receive Ground

The clock signal direction depends on the synchronization mode selected (codirectional, contradirectional, master, slave); see section 2.3.1.

User Guide - N56715450104 Page A2-4 Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING

Connector #2 (HE5, 15-way) female

Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Name H8_EM_2N H8_EM_2P H8_REC_2N RX_DATA_2P RX_DATA_2N H8_REC_2P GND TX_DATA_2P TX_DATA_2N H64_EM_2P H64_EM_2N H64_REC_2P H64_REC_2N GND H8_EM_3N H8_EM_3P H8_REC_3N RX_DATA_3P RX_DATA_3N H8_REC_3P GND TX_DATA_3P TX_DATA_3N H64_EM_3P H64_EM_3N H64_REC_3P H64_REC_3N GND

Description 8 kHz sync clock - Transmit 8 kHz sync clock - Transmit 8 kHz sync clock - Receive Data In - Receive Data In - Receive 8 kHz sync clock - Receive Ground Data Out - Transmit Data Out - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Receive 64 kHz sync clock - Receive Ground 8 kHz sync clock - Transmit 8 kHz sync clock - Transmit 8 kHz sync clock - Receive Data In - Receive Data In - Receive 8 kHz sync clock - Receive Ground Data Out - Transmit Data Out - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Transmit 64 kHz sync clock - Receive 64 kHz sync clock - Receive Ground

#3 (HE5, 15-way) female

1 2 3 4 5 6 7 8 9 10 11 12 13 14

The clock signal direction depends on the synchronization mode selected (codirectional, contradirectional, master, slave); see section 2.3.1.

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 PageA2-5

2 - INSTALLATION - COMMISSIONING

Connector LOOPS (HE5, 9-way) female 2 3 4 5 6 8

Pin

Name R_DF_EQUIP T_DF_EQUIP R_DF_V11 T_DF_V11 C_DF_EQUIP C_DF_V11

Description Normally open contact - Equipment fault Normally closed contact - Equipment fault Normally closed contact Remote fault Normally open contact Remote fault Common - Equipment fault Common - Remote fault

User Guide - N56715450104 Page A2-6 Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING

EOW 300 More than three ports interconnexion

Three line ports are available on the EOW 300 . If more than three ports are required, it's possible to associate several EOW as described below.

EOW 300

EOW 300

EOW 300

Figure 2.6 EOW 300 Association

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A2-7

2 - INSTALLATION - COMMISSIONING

2.3.1 - Z interface configuration


The Z interface is designed to operate with a telephone with 600 ohms impedance. Only one of switches S607-1 to S607-5 must be ON (receive gain setting). Group Z interface Name S607-1 S607-2 S607-3 S607-4 S607-5 S607-6 Use Relative receive level set at -1 dB Relative receive level set at -4 dB Relative receive level set at -7 dB Relative receive level set at -10 dB Relative receive level set at -13 dB OFF = Relative transmit level set at +0 dB ON = S607-7 Relative transmit level set at +3 dB ON Factory setting OFF OFF ON OFF OFF OFF

OFF = Ringing frequency = 25 Hz ON = Ringing frequency = 50 Hz

General

S607-8

OFF = Transparent mode enabled ON = Transparent mode disabled

OFF

S608-1

OFF = Equipment in slave mode ON = Equipment in master mode OB unconnected OB linked to electrical 0 V EQUIP_FAULT loop not referenced EQUIP_FAULT loop referenced to OB V11_FAULT loop not referenced V11_FAULT loop referenced to OB

OFF

E51

Pins 2-3 : Pins 1-2 :

Pins 2-3

E53

Pins 2-3 : Pins 1-2 :

Pins 2-3

E54

Pins 2-3 : Pins 1-2 :

Pins 2-3

IMPORTANT: * Jumpers E700 and E701 must be on pins 1-2 for the AA01 and AA02 issues (suppression from AA03).

User Guide - N56715450104 Page A2-8 Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING

2.3.2 - Network configurations

EOW300

Transmission Equipment

EOW300

Transmission Equipment

Transmission Equipment

EOW300

EOW300 EOW300 EOW300

Transmission Equipment EOW300 in "master" mode

EOW300

EOW300

EOW300

EOW300

Transmission Equipment

EOW300

Transmission Equipment

Transmission Equipment

EOW300

Transmission Equipment EOW300 in "master" mode

Transmission Equipment

EOW300

EOW300

Transmission Equipment

Transmission Equipment

Transmission Equipment

Figure 2.8 - Typical configuration

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A2-9

2 - INSTALLATION - COMMISSIONING

2.3.3.1 - Linear networks


In linear networks, all EOW300 units whether or not linked to transmission equipment must be in "slave ring" mode. Any V.11 port may be used.

2.3.3.2 - Ring networks


"Ring master" mode: When the EOW300 units are on a ring network, only one unit in the ring must be configured in "ring master" mode. Each EOW300 in "ring master" mode is designed to: disconnect digital summing and signalling in both transmission directions when the communication ring is correctly closed. switch to "ring slave" mode (standard mode) when it detects the opening of the communication ring when a fault has been declared (see section 1.2.3).

Rules for setting the equipment to "ring master": If, in a ring network, only one EOW300 is configured with three V.11 ports active, this equipment must be in "ring master" mode. If, in a ring network, several EOW300 units are configured with three V.11 ports active, one of these units must be in "ring master" mode. If, in a ring network, no EOW300 is configured with three V.11 ports active, the unit in "ring master" mode can be set any way.

Important: An EOW300 "ring master" mode unit must have ports 1 and 2 on the communication ring of which it is master.

User Guide - N56715450104 Page A2-10 Reproduction and communication not allowed without written authorization from Siemens AG

2 - INSTALLATION - COMMISSIONING

2.4 - Commissioning
On each unit, check when powering up that: the selftest is OK: Engaged, remote, port#1, port#2, port#3 and master come on in turn every 0.5 seconds. The V.11 channels linked to units already powered up must be enabled and those linked to units powered down must indicate a fault. When all the EOW300 units in a network have been powered up, it is advisable to execute a General reset (programming sequence *0 *0) from any station.

Important: The setup parameters are saved in the event of a power down or power outage.

2.5 - Operation
Fault "equipment" "remote" Off: On: Off: On: LED action No fault Equipment fault No fault Fault on one of the V.11 channels or fault with "master" mode Loop action Active: No fault Inactive: Equipment fault Inactive: No fault Active: Fault on one of the V.11 channels or fault with "master" mode

Note:

Loop inactive Loop active

= Contact established between C_DF_XXX and R_DF_XXX = Contact established between C_DF_XXX and T_DF_XXX

Note: If there is a fault on network equipment (fibre breakage between ADR equipment for example), the quality of the speech between the affected unit and the others may be degraded.

Reproduction and communication not allowed without written authorization from Siemens AG

User Guide - N56715450104 Page A2-11

User Guide - N56715450104 Page A2-12 Reproduction and communication not allowed without written authorization from Siemens AG