Sunteți pe pagina 1din 64

Local Climate. Global Comfort.

air curtains radiant heaters fan heaters convectors controls

Welcome

to the Frico Mini Catalogue. The Catalogue displays an overview of the Frico range of Commercial Heating solutions for various applications. The brochure features our ranges of Air Curtains, Radiant Heaters, Fan Heaters, Convectors and Control Packages. Frico Ltd are pleased to be expanding their product offering to BSS Industrial, which now includes the Frico range of Commercial Electric Heating products. There has been a longstanding partnership between the companies with Frico manufacturing the BOSS branded Air Curtains for many years. BSS Industrial can now offer an extensive range of Electrically Heated products for the Commercial sector from a single manufacturing source. BSS Industrial is a leading distributor of pipeline and heating equipment. The company forms the Industrial Division of the 1.2 billion BSS Group business and believes its success is due to how it differentiates itself in a busy market place. BSS Industrial operates via a national network of almost 60 branches which enables them to service a wide range of sectors and by working closely with suppliers and partners, is capable of developing bespoke offerings for each of its customers including quality products, specifications, technical support and after sales care. BSS Industrial is quality driven, through world class product brands and the development of its employees. BSS believes in developing strong relationships with its customers and from this, building partnership agreements which enable the company to tailor their services to meet specific needs. The company continues to develop its brand network and logistics solutions to ensure it retains its number one position. To support the development of the product range both BSS and Frico Ltd have a network of Technical Sales Engineers that are willing to offer both product and project support and advice. Further information can be provided by the BSS Technical Support Team who will assist in the design and selection of products that are most suited to the specific application. We welcome the opportunity to discuss products and projects with you in the future.

Kevin Goodison Sales Director Frico Limited

Frico Ltd 72 Cheston Road Birmingham B7 5EJ United Kingdom Phone: 0121 322 0854 Fax: 0121 322 0858 sales@frico.co.uk www.frico.co.uk

Contents
Frico Thermozone Air curtains
Introduction Thermozone guidelines Thermozone AD 100, ADA Thermozone AD 200 Thermozone AD 300 Thermozone Portier Thermozone AR 200, recessed Thermozone AR 300, recessed Thermozone ADR, recessed Thermozone AC Corinte Thermozone AD Corinte Thermozone SF for circular and revolving doors , Thermozone RD, for circular and revolving doors BOSS S10, S15 BOSS LP S10/S15 recessed , Thermozone AD 400 Thermozone AG 4000 Thermozone AG 4500/5000 Thermozone AGV 4000 Thermozone AC 500, AC 600 Thermozone AGI Thermozone ADA Cool, cold storage Advanced energy controls ADEA, SMBS Output and speed controls CB, ADSR54, RTRD Other accessories 6 7 10 11 12 13 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 4

Radiant heaters
Introduction Comfort Panel SZR, water heated, recessed Comfort Panel SZ, water heated Thermoplus Thermocassette Elztrip EZ 100 Elztrip EZ 200 Elztrip EZ 300 Infrared heater IR Infrared heater IRCF Infrared heater IH weatherproof, outdoor Infrared heater CIR weatherproof, outdoor Infrared heater ELIR weatherproof, outdoor Controls/energy regulators ERP CIRT, S123 , 32 36 37 38 38 39 39 40 40 41 41 42 42 43

Fan heaters
Introduction K21 2kW Tiger, 2-9 kW, 15 kW, 20 and 30 kW P3110 3kW 110V PA1006 3kW door heater Cat 3-9 kW Elektra, for demanding environments Panther 6-15 kW, 20 and 30 kW Panther, accessories SW, water heated SW, accessories 44 45 45 46 46 46 47 48 49 50 51

Ceiling fans
Ceiling fan ICF 52

Convectors
Introduction Ribbed pipe radiator Frost guard Fan convector PFE, PFD Fan convector PFW, water heated ThermoWarm Bench heater 53 53 53 54 54 55 55

Thermostats and controls


Introduction 2-step room thermostats RTI2, RTI2V Timer CBT Room thermostats T10, TK10, TKS16, TD10 Thermostats KRT1900, KRTV19 2-step room thermostats KRT2800 Water controls Technical data
Design and specifications are subject to change without notice. See www.frico.co.uk for latest updated info.

56 56 56 57 57 57 58 59

Frico products
Todays high and increasing energy prices often make heating costs substantial. Frico strives to develop products and systems that provide energy saving heating solutions and better heating comfort at the same time. Reducing energy losses and making optimum use of the heat is also important. Air curtains in doorways and openings, radiant heaters or ceiling fans where the ceiling is high are examples of products that contribute to large energy savings.

Air curtains It makes sound economic sense to create an efficient and invisible door that keeps the heat inside. Air curtains can be even more effective when used in air conditioned or cold storage buildings. Thermozone technology with its precisely adjusted air velocity gives even protection throughout the opening. Frico air curtains provide the most efficient separation with the lowest possible energy consumption, regardless of whether it is the heat or the cold that you want to keep inside.

Radiant heaters Frico radiant heaters imitate the sun, the most comfortable and efficient heat source available. The heat is emitted only when the rays hit a surface and the room temperature can thus be lowered while occupants experience a comfortable environment. This makes radiant heaters well suited for zone and spot heating, for example to avoid cold draughts from windows. Radiant heaters are easy to install and require minimum maintenance. They heat directly when switched on and give no air movement.

Fan heaters We are proud of the worldwide fame Frico fan heaters have gained. They are reliable and are designed for long life. Our range covers all needs. The investment cost is low compared to other heating systems. A great advantage of fan heaters is the option of combining heating and ventilation. Frico fan heaters are compact, low noise and light weight. They are available for electrical heating as well as for water heating.

Convectors The circulation of air that forms in a room where the air is affected by a heat source is called convection. The air gets warm and rises, then cools and returns to be heated again. Heat disperses effectively while the upward directed warm air stream is utilized to counteract cold draughts from windows for example.

Ceiling fan Ceiling fans push down overheated air from the ceiling to the living area. Losses are decreased and the heat is used to best effect.

Thermostats and controls The key to energy efficient heating and good comfort is the combination of heating products and good controls. Frico offers a wide range of thermostats and controls, read more under each product or in the Frico Catalogues.

More information More information on Frico and Frico products can be found on our website www.frico.co.uk, in our main catalogues and other printed material that you can order from us or from our distributors.

Good reasons to choose Frico


Seventy five years experience of developing products for the varied Nordic climate has provided us with a unique knowledge bank. This is our foundation when creating today's energy efficient solutions for a comfortable indoor climate. Leading technology and design Frico is the leading supplier of air curtains, radiant heaters and fan heaters. All our products are well designed in good Scandinavian tradition. Knowledge and resources Since we develop our own products, our knowledge on how to create an energy efficient indoor climate is constantly growing. We have one of Europe's most modern and advanced air and sound laboratories to aid us. Qualified local support Frico is present locally in some 50 countries worldwide with a network of wholly-owned subsidiaries and independent distributors. Our highly qualified representatives are carefully chosen and together we are able to provide you with the best possible support. Frico Academy The Academy is an important platform for networking and sharing inspiration and knowledge between us and our distributors around the world. By exchanging ideas and knowledge we all learn more and are able to give our customers even better support and advice. Through the Frico Academy we share our knowledge on theory and technology, as well as product knowledge and insights in manufacturing and product development. Quality and long life Frico offers consistent and high product quality. All products are CE compliant and most of them are approved by the Swedish testing institute SEMKO, as well as several other testing institutes worldwide. Our product warranty covers manufacturing faults and is valid for three years. Frico products are designed for long life and are easy to maintain. We provide reliable maintenance and service support which includes the availability of spare parts for at least ten years. Research and development We have one of Europes most modern air and sound laboratories. Research and measurements are done regularly to develop new products but also to enhance and improve existing products. Measurements are done according to AMCA and ISO standards.

Frico Frico distributors

Frico's head office is located outside Gteborg in Sweden and we have subsidiaries in Norway, France, United Kingdom, Germany, Russia, China, Spain, Austria and the Netherlands. Dealers represent us in more than 50 countries all over the world. We manufacture at production units in Skinnskatteberg, Sweden and at other ISO-certified production units in Europe. Our warehouses are strategically placed in Sweden, UK, France, Spain and Germany.
5

Air curtains - Thermozone


Thermozone air curtains create an invisible barrier at openings and doors which separates different temperature zones without limiting access for people and vehicles. With Thermozone Technology an efficient air separation is created in combination with a low sound level, giving comfortable climate and large energy savings. Thermozone air curtains are appreciated worldwide for their quality and operating efficiency, and are currently used in over 50 countries. Thermozone technology Thanks to Thermozone technology, performance can be precisely adjusted to obtain an air curtain with efficient separation that is also comfortable to pass through. Thermozone air curtains are optimized in: Airflow geometry Performance Sound level Scandinavian design Frico cooperates with leading architects and product designers to create todays aesthetic products. The Thermozone range has an elegant Scandinavian design and for visible mounting there are models that harmonize with exclusive shop interiors as well as industrial buildings. Recessed mounting is also possible with only the outlet/ inlet visible. Air curtain knowledge We at Frico know most of what there is to know about air curtains and are happy to share that knowledge. We arrange for example The Frico Academy, a training forum for our distributors. Please see "Thermozone air curtain catalogue" for further information, or contact us directly.
R

Energy savings and good indoor climate In many buildings, such as shops, warehouses, industrial premises and goods terminals, doorways are open for a significant portion of the day. Expensive heated or cooled air will be lost, especially when the difference between the inside and outside temperatures is substantial. Low sound level and high performance The Thermozone range has been developed and is manufactured in our plant in Skinnskatteberg, Sweden. Here we have one of the most sophisticated airflow and sound laboratories in Europe. Advanced equipment and expertise make it possible to produce air curtain products with the lowest sound level and the best performance.

[C] [cm] [cm]

Opening

[cm]

Opening

[cm]

Opening without Thermozone The heated or conditioned air escapes through this unprotected opening. The result is energy loss and poor comfort.

Opening with correctly adjusted Thermozone A sharp separation between different temperature zones is obtained with a correctly set up air curtain. Thermozone creates a barrier that effectively prevents undesired air flows.

Air curtains - Thermozone


Choose the right air curtain For optimal air curtain effect, it is important to choose the right air curtain. Thermozone air curtains are available for doorways of any width and for heights up to 8 metres. They blow from above, from the side or from below. Choose between electrical, water heated or unheated versions. To get the most out of the product, the following hints are important to bear in mind. The installation height is crucial. The air curtain units should cover the whole width (or height) of the opening. Thermozone can be obtained in different lengths. For wide (high) openings, several units are mounted beside (on top) of each other. The units should be positioned as close to the opening as possible. For optimal performance it is important that the pressure difference between outside and inside is not too big. Control For optimal comfort and energy saving the air curtain needs to be controlled according to the requirements and conditions at hand. A quick and precise control is easily obtained. Our control kits on 3 different levels for each product cover most needs. Read more about the control kits in our air curtain catalogue or on www.frico.co.uk. A i r cu rt ai ns
Additional features Cable and plug. AD105: only cable. Cable and plug. Page 10 10 11 12 Brushed stainless steel Recessed model. Recessed model. Recessed model. Brushed stainless steel as standard. Polished stainless steel as standard. For revolving doors. For revolving doors. Front air inlet, modular construction. Front air inlet, modular construction. Brushed stainless steel as standard. Recessed model. 13 13 14 15 16 17 18 19 20 20 21 21 22 23 24 25 26 26 27 Special terminals for easy connection of several units. Cable and plug. 28 Horizontal

Air curtains - overview


Type AD100 ADA AD200 AD300 Portier AR200 AR300 ADR200/300 AC Corinte AD Corinte SF RD S10 S15 LP S10/15 recessed AD400 AG4000 AG4500/5000 AGV4000 AC500 AC600 AGI ADA Cool Application Small openings Entrance/cold storage Entrance/cold storage Entrance/cold storage Entrance Entrance Entrance Entrance Entrance Entrance Entrance Entrance Entrance Entrance Entrance Entrance Industry/cold storage Industry/cold storage Industry/cold storage Industry/cold storage Industry Industry Industry Cold storage Installation height/width Up to 1.5 m Up to 2.5 m Up to 2.5 m 2.5 m - 3.5 m Up to 2.5 m Up to 2.5 m Up to 3.5 m Up to 3.5 m Up to 2.5 m Up to 3 m Up to 4 m Up to 3 m Up to 2.7 m Up to 4 m Up to 2.5 m Up to 3.7 m 3m-4m Up to 4 m Up to 5 m Up to 4 m 3m-6m Large doorways Large doorways Up to 2.5 m El. Water Ambient Mounting heated heated unheated

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 1 1 1

Horizontal Horizontal Horizontal Horizontal Horizontal

2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1

Horizontal Horizontal Horizontal/vertical Horizontal/vertical Vertical Horizontal

1 1

Horizontal Horizontal Horizontal/vertical Horizontal Horizontal Horizontal Horizontal Vertical Horizontal/vertical Vertical Horizontal/vertical Horizontal

Air curtains - Thermozone


Quick guide to choosing the right air curtain
Thermozone air curtains are available for openings of different sizes and for different application areas. On the following pages are some typical cases which are intended to facilitate your choice. See previous page for more detailed information on important factors to consider when choosing an air curtain. Please note that it is the installation height that is decisive and not the height of the opening. Basic criteria: 1. Type of premises: store, warehouse etc. 2. Height: installation height 3. Width: installation width 4. Mounting: horizontal or vertical 5. Connection: ambient, unheated (A), electrical (E), water (W)

Small openings
Kiosk or service hatch 1. Type of premises: Kiosk 2. Installation height: 1 m 3. Installation width: 0,8 m 4. Mounting: Horizontal 5. Connection: Electrical Recommendation: An AD102/103 is recommended for these conditions. For the 1,5 metre opening, two units are mounted side by side to cover the whole width.

1m

1m

0,8 m

1,5 m

Entrance
Shop 1. Type of premises: Shop 2. Installation height: 2,1 m 3. Installation width: 1 m 4. Mounting: Horizontal 5. Connection: Electrical Recommendation: An AD210E06 or AD210E09 is recommended for these conditions. 2. Installation height: 2,2 m 3. Installation width: 2 m Recommendation: A shop with a large entrance and a lot of traffic through the opening requires a larger unit to obtain a comfortable climate. For these conditions we recommend AD320E18. Bank 1. Type of premises: Bank 2. Installation height: 2,2 m 3. Installation width: 2 m 4. Mounting: Horizontal or vertical 5. Connection: Water Recommendation: For an opening with high demands on design and performance we recommend one or two AD Corinte depending on the premises. AD Corinte can be installed horizontally or vertically.

2,1 m

2,2 m

1m

2m

2,2 m

2m

2,2 m

2m

Air curtains - Thermozone


Industry
Goods reception, grocery store 1. Type of premises: Goods reception, grocery store 2. Installation height: 3 m 3. Installation width: 3 m 4. Mounting: Horizontal 5. Connection: Water Recommendation: Two AD315W are recommended for these conditions. A i r cu rt ai ns
3m 3m 4m 4m 6m 4m 2,5 m 2,5 m

Warehouse 1. Type of premises: Warehouse 2. Installation height: 4 m 3. Installation width: 4 m 4. Mounting: Vertical 5. Connection: Water Recommendation: Two vertically mounted AGV4020W beside the opening, one at each side are recommended for these conditions.

Factory, heavy industry 1. Type of premises: Factory, heavy industry 2. Installation height: 6 m 3. Installation width: 4 m 4. Mounting: Vertical 5. Connection: Ambient Recommendation: For these conditions we recommend AC600. Air is pressed out at high speed through a narrow slot in the floor inside the opening. AC600 provides nearly 100 % protection against cold draughts along the floor.

Cold storage
Cold room 1. Type of premises: Cold room 2. Installation height: 2,5 m 3. Installation width: 2,5 m 4. Mounting: Horizontal 5. Connection: Ambient Recommendation: Two ADA Cool are recommended for these conditions, mounted side by side above the opening.

Air curtains - Thermozone Small openings and Entrance

Thermozone AD 100
Designed primarily for smaller openings such as kiosk and service hatches. The airflow can be regulated in two steps. Resetable overheat protection. Built-in thermostat (5-35 C). Models AD102 and AD103 are equipped with cable and plug, AD105 only cable. Height: 217 mm Depth: 131 mm Colour: white, RAL 9016. CE compliant. Supply: 230V~

Thermozone ADA
Designed to prevent loss of conditioned air. Installation height up to 2,5 metres. Suitable where space is limited between the ceiling and the upper edge of the doorway. Without heat. With cable and plug. Built-in switch for high/low speed. Height: 235 mm Depth: 215 mm Colour: white, RAL 9016. CE compliant.

1,5 m

0,8 m

2,5 m 0,9 / 1,2 m

Thermozone AD 100, electrically heated (IP20)


Type AD102 AD103 AD105 Heat output [kW] 0/1/2 0/2/3 0/3/4.5 Airflow [m/h] 400 400 500

3
Length [mm] 806 806 806

Thermozone ADA, ambient, unheated (IP21)


Type ADA090H ADA120H Heat output [kW] 0 0 Airflow [m/h] 1150 1400

1
Length [mm] 900 1200

Sound level [dB(A)] 36/48 36/48 50

Sound level [dB(A)] 43/54 44/51

10

Air curtains - Thermozone Entrance


A i r cu rt ai ns

Thermozone AD 200 A/E/W


Installation height up to 2,5 metres. Recessed mounting possible. Height: 225 mm Depth: 350 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Thermozone AD 200 W, water heated (IP21)
Type

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AD210W 9 1200 41/51 1020 AD215W 13.9 1800 43/53 1530 AD220W 17.9 2400 44/54 1960 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

2,5 m

1 / 1,5 / 2 m

Control kits AD200W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board

Thermozone AD 200 A, ambient, unheated (IP21)


Type AD210A AD215A AD220A Heat output [kW] 0 0 0 Airflow [m/h] 1400 2100 2800

1
Length [mm] 1020 1530 1960

Sound level [dB(A)] 41/51 43/53 44/54

CK03 Level 3

Control kit AD200A 1 Level 1 CB30N, controls the airflow in 3 steps

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

Thermozone AD 200 C, electrically heated, built-in thermostat and control box, cable and plug (IP21). Supply 230V~ 3
Type AD210C03 AD210C05 Heat output [kW] 0/2/3 0/2.3/4.5 Airflow [m/h] 1400 1400 Sound level [dB(A)] 41/47 41/47 Length [mm] 1020 1020

Accessories - AD 200 A/E/W


Type Description

Thermozone AD 200 E, electrically heated (IP21). Supply 400V3N~* 3


Heat output Airflow Sound level [kW] [m/h] [dB(A)] AD210E03* 0/1.5/3 1400 41/51 AD210E06 0/3/6 1400 41/51 AD210E09 0/4.5/9 1400 41/51 AD215E05 0/2/4.5 2100 43/53 AD215E09 0/4.5/9 2100 43/53 AD215E14 0/7/13.5 2100 43/53 AD220E12 0/6/12 2800 44/54 AD220E18 0/9/18 2800 44/54 *) All models except AD210E03 which has supply 230V~ Type Length [mm] 1020 1020 1020 1530 1530 1530 1960 1960

Control kits AD200E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03 Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board

CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 29-31 and 56-58.

11

Air curtains - Thermozone Entrance

Thermozone AD 300 A/E/W


Installation height 2,5-3,5 metres. Combines high performance with a compact size and an elegant design. Recessed mounting possible. Height: 340 mm Depth: 490 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Thermozone AD 300 W, water heated (IP20). Supply 230V~
Type

2,5 - 3,5 m

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AD310W 25 1800 44/57 1025 AD315W 42.1 3000 46/59 1565 AD320W 52.5 3600 47/60 2028 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

1 / 1,5 / 2 m

Control kits AD300W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CK03 Level 3 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board

Thermozone AD 300 A, ambient, unheated (IP20).


Type AD310A AD315A AD320A Heat output [kW] 0 0 0 Airflow [m/h] 1900 3200 3800 Sound level [dB(A)] 46/57 47/60 50/61

1
Length [mm] 1025 1565 2028

Control kits AD300A 1 Level 1: CB30N, controls the airflow in 3 steps Level 2: CB30N and MDC, magnetic door contact with time relay

*) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit.

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. Accessories - AD 300 A/E/W
Type Description

Thermozone AD 300 E, electrically heated (IP20) Supply 400V3~, control 230V~


Type AD310E09 AD315E14 AD320E18 Heat output [kW] 0/4.5/9 0/7/13.5 0/9/18 Airflow [m/h] 1900 3200 3800

3
Length [mm] 1025 1565 2028

Sound level [dB(A)] 46/57 47/60 50/61

Control kits AD300E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03 Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board

*) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit.

CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAIB Internal control board ADEAGD1 Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 29-31 and 56-58.

12

Air curtains - Thermozone Entrance


A i r cu rt ai ns

Thermozone Portier 200 E


For exclusive entrances. Installation height up to 2.5 metres. Mounting brackets available as an accessory. Overheat protection. Height: 280 mm Depth: 295 mm Colour: brushed stainless steel. CE compliant.

Thermozone AR 200
AR200 is especially suited for environments requiring unobtrusive installation. It is recessed in ceilings above entry doors and other small doors where the height is no greater than 2.5 metres. A low unit height makes it possible to install AR200 where ceiling space is limited. The recessed installation and low sound level makes AR200 very discreet. The visible bottom plate may be painted 1 / 1,5 / 2 m to make it blend even better with the premises. Just one model per length, with a choice of outputs and voltages selectable on installation making it simple and flexible to adapt the output to current need. Installation height up to 2.5 metres. Height: 198 mm Depht: 432 mm Colour (bottom plate): white, RAL 9016 CE compliant. Thermozone AR200E, electrically heated (IP20)
Type 2,5 m

2,5 m 1 / 1,5 m

Thermozone Portier 200E, electrically heated (IP21)


Type PS210E03 PS210E06 PS210E09 PS215E09 PS215E14 Heat output [kW] 0/1.5/3 0/3/6 0/4.5/9 0/4.5/9 0/6.7/13.5 Airflow [m/h] 1200 1200 1200 1900 1900 Sound level [dB(A)] 44/50 44/50 44/50 39/50 39/50

3
Length [mm] 1020 1020 1020 1530 1530

Control kits Portier 200E 3 Level 1 CB22, controls the airflow in 2 steps and the heat output in 2 steps RTI2, 2-step room thermostat Level 2 Level 3 CB22, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAEB, external control board

Accessories - Portier 200E


Type Description

CB22 Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 MDC Magnetic door contact with time relay, IP44 ADPK1 Suspension kit, max 1 m P2WB Suspension brackets (pair) P2JK Joining kit 2x1 m More information about accessories on pages 25-27 and 56-58.
1

Length Sound Airflow Output Output level steps steps 400V3N~ 230V~ [mm] [dB(A)] [m/h] [kW] [kW] 0/3 0/3/6 AR210E09 0/6/9 1200 34/50 1042 0/3 0/3/5 0/4,5 0/3,4/6,8 AR215E11 0/6,8/11,3 1750 34/50 1552 0/4,5 0/4,5/6,8 0/6 0/6/12 AR220E18 0/12/18 2400 40/54 2042 0/6 0/6/10 AR200 is delivered as 9 kW, 11 kW and 18 kW (400 V3N~) models, but they are convertible to 230 V~ and different outputs as shown in above table.

Control kits AR200E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CB32N, RTI2 and MDC, magnetic door contact with time relay

P2WB

P2JK

Accessories - AR 200E
Type CK01E CK02E CB32N T10 RTI2 MDC CBT Description Control kit Electric level 1 (CB32N, RTI2) Control kit Electric level 2 (CB32N, RTI2, MDC) Control box (E) Room thermostat, IP30 2-step room thermostat, IP44 Magnetic door contact with time relay, IP44 Electronic timer, IP44

13
3

Air curtains - Thermozone Entrance

Thermozone AR 300 E/W


AR300 is especially suited for environments requiring unobtrusive installation. The recessed installation is very discreet and the built-in control contributes further to the concealed appearance. Installation height up to 3,5 metres. Easy to service via a large hatch in the bottom of the unit. The filter is cleaned from the outside. Height: 302 mm Depth: 595 mm Colour (frame and hatch): white, RAL9016 CE compliant. Control AR300 The built-in control of AR300 is designed to give the highest level of functionality while minimizing installation and daily operation. No additional wiring or external controls are needed. The air curtain operates at its maximum performance in all situations and is not dependent on day-to-day adjustments. When the door is open the air curtain separates outdoor and indoor air and provides heat if it is needed. When the door is closed the air curtain operates as part of the heating system supplying additional heat if indoor temperature falls below desired temperature. There are also possibilities to connect the air curtain to a BMS system for on/off control and alarm indication.

3,5 m 1 / 1,5 / 2 m

Thermozone AR 300 E, electrically heated (IP44). Supply 400V3~ 3


Type AR310E09 AR315E14 AR320E18 Heat output [kW] 0/4.5/9 0/7/13.5 0/9/18 Airflow [m/h] 2000 2800 4000 Sound level [dB(A)] 43/59 43/60 46/63 Length [mm] 1057 1567 2073

Accessories - AR 300 W
Type Description

Thermozone AR 300 W, water heated (IP44). Supply 230V~


Type

VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator More information about accessories on page 58.

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AR310W 16 2000 43/58 1057 AR315W 23 2800 43/59 1567 AR320W 33 4000 46/62 2073 *Applicable at water temperature 82/71C, air temperature, in +15C.

Type

Water temperature 60/40 80/60 81/72 60/40 80/60 81/72 60/40 80/60 81/72

VR20 X

VR25

AR310W

X X X X X X X X

AR315W

AR320W

The thermostat setting and open door fan speed selection is hidden under the cover.

The IR-eye detects when the door is opened and closed. The thermostat is located by the inlet grille and heat or ambient mode is set by a push button. Alarm indication by LED.

14

Air curtains - Thermozone Entrance


A i r cu rt ai ns

Thermozone ADR E/W


ADR is especially suited for environments requiring unobtrusive installation. For recessed mounting in false ceilings. Installation height up to 3,5 metres. Only the discreetly placed inlet and outlet grilles are visible. The filter is cleaned from outside. Height: 260-460 mm (adjustable) Depth: 720 mm CE compliant. Thermozone ADR W, water heated (IP23). Supply 230V~
Type

1 / 1,5 / 2 m

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] ADR210WH 10.1 1350 40/57 1000 ADR215WH 14.5 2000 43/60 1500 ADR220WH 18.5 2600 44/60 2000 ADR310WH 15.0 1800 44/61 1000 ADR315WH 23.5 2400 43/60 1500 ADR320WH 28.2 3400 45/62 2000 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

3,5 m

Thermozone ADR E, electrically heated (IP23). Supply 400V3~


Type ADR210E ADR215E ADR220E ADR310E ADR315E ADR320E Heat output [kW] 0/6/9 0/8/12 0/12/18 0/6/9 0/8/12 0/12/18 Airflow [m/h] 1400 2100 2700 1900 2500 3500 Sound level [dB(A)] 40/57 43/60 44/60 44/61 43/60 45/62 Length [mm] 1000 1500 2000 1000 1500 2000

Control kits ADR W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CK03GD Level 3 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Control kits ADR E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03GD Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

Accessories - ADR E/W


Type Description

CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03GD Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator More information about accessories on pages 29-31 and 56-58.

15

Air curtains - Thermozone Entrance

1,5 / 2,0 / 2,5 / 3,0 m

Thermozone AC Corinte E/W


For exclusive entrances with high demands on design, noise level and finish. Slim design in stainless steel. Mounted with one unit on either side of the opening, thus creating a classic symmetry. Can also be mounted horizontally. Installation width up to 5 metres (2 units). Installation height up to 3 metres. Height/depth: 393 mm Depth/width: 314 mm Colour: brushed stainless steel (option: polished or mirror polished stainless steel) Supply: ACC E: 400V3~, ACC W: 230V~. CE compliant. Thermozone AC Corinte for horizontal mounting Thermozone AC Corinte E, electrically heated (IP20)
Type Heat output [kW] 9 12 18 18 24 Airflow [m/h] 1900 2600 3800 4500 5100

5m

Accessories - ACC E/W


Type CK01E CK02E CK03GD CK01W CK02W CB30N CB32N ADEA ADEAEB ADEAIS ADEAGD1 Description

ACC1000EH ACC1500EH ACC2000EH ACC2500EH ACC3000EH

Sound level Length [dB(A)] [mm] 44/61 1000 45/62 1500 47/64 2000 48/65 2500 48/65 3000

Thermozone AC Corinte WH, water heated (IP20)


Type

Length Sound Airflow Heat level output*1 [mm] [dB(A)] [m/h] [kW] ACC1000WHH 11 1900 44/61 1000 ACC1500WHH 1500 17 2600 45/62 ACC2000WHH 24 3800 47/64 2000 ACC2500WHH 30 4500 48/65 2500 ACC3000WHH 35 5100 48/65 3000 *1) Applicable at water temperature 82/71 C, air temperature, in +15 C.

Control kit Electric level 1 (CB32N, RTI2) Control kit Electric level 2 (CB32N, RTI2, MDC) Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) Control kit Water level 1 (CB30N, T10) Control kit Water level 2 (CB30N, RTI2, MDC) Control box (A/W) Control box (E) Air curtain control External control board, IP55 External room sensor, IP30 Additional control board to acheive ADEA and BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat, knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator AXP300 Collision protection More information about accessories on pages 29-31 and 56-58.

Ordering key
ACC - Length - Heat medium - Unit shape - Connections position - Finish / Material Example: ACC - 1500 - WL - VL - 2 - P

Thermozone AC Corinte for vertical mounting Thermozone AC Corinte E, electrically heated (IP20)
Type Heat output [kW] 12 18 18 24 Airflow [m/h] 2600 3800 4500 5100 Sound level [dB(A)] 45/62 47/64 48/65 48/65

Length

1000, 1500, 2000, 2500 or 3000 WL (low temperature water), WH (high temperature water) or E (electrical). H (Horizontal), VL (Vertical Left) or VR (Vertical Right) seen from the inside 1 or 2, see below. B240 = Brushed grain 240 P = Polished bright annealed M = Mirror polished

3
Height [mm] 1500 2000 2500 3000

Heat medium

Unit shape Connections position Finish / material

ACC1500EVL/R ACC2000EVL/R ACC2500EVL/R ACC3000EVL/R

Thermozone AC Corinte WH, water heated (IP20)


Type

Connections position
A A

Height Sound Airflow Heat level output*1 [mm] [dB(A)] [m/h] [kW] ACC1500WHVL/R 17 2600 45/62 1500 ACC2000WHVL/R 24 3800 47/64 2000 ACC2500WHVL/R 30 4500 48/65 2500 ACC3000WHVL/R 35 5100 48/65 3000 *1) Applicable at water temperature 82/71 C, air temperature, in +15 C.
HL HR

3m 1,0 / 1,5 / 2,0 / 2,5 / 3,0 m

Control kits ACC E/W: see control kits AG4000 page 24 16

Air curtains - Thermozone Entrance


A i r cu rt ai ns
1,7 / 2,2 m

2,2 / 2,5 m

Thermozone AD Corinte A/E/W


For exclusive entrances with high demands on design, noise level and finish. Mounted with one unit on either side of the opening, thus creating a classic symmetry. Can also be mounted horizontally. Installation width up to 5,5 metres (2 units). Installation height up to 3,5 metres. Height/depth: 500 mm Depth/width: 350 mm Colour: polished stainless steel (option: brushed or mirror polished stainless steel). Supply: Delivered connected for 230V3~. Convertible from 230V3~ to 400V3~. CE compliant.

5,5 m

Thermozone AD Corinte W, water heated (IP20)


Type

3,5 m

Height/ Sound Airflow Heat Length level output*3 [mm] [dB(A)] [m/h] [kW] ADCH17W*1 33 3000 38/58 1700 ADCH22W*1 46 4000 39/59 2200 ADCV22W*2 46 4000 39/59 2200 ADCV25W*2 52 4500 40/60 2450 *1) For horizontal mounting (H= horizontal). *2) For vertical mounting (V= vertical). *3) Applicable at water temperature 82/71C, air temperature, in +15 C

Thermozone AD Corinte A, ambient, unheated (IP20)


Airflow Heat output [m/h] [kW] ADCH17A*1 0 3000 ADCH22A*1 0 4000 ADCV22A*2 0 4000 ADCV25A*2 0 4500 *) For horizontal mounting (H= horizontal). *) For vertical mounting (V= vertical). Type Sound level [dB(A)] 40/60 42/61 42/61 43/63

1
Height/ Length [mm] 1700 2200 2200 2450

Control kits AD Corinte W 2 Level 1 FC15M, frequency inverter T10, room thermostat VR20/25*, valve set Level 2 ADEA, air curtain control with outdoor sensor, builtin room sensor and door contact ADEAEB, external control board VR20/25*, valve set) FC15A, frequency inverter
*) option: TVV20/25 with SD20 For control recommendations please contact Frico Technical Department for advise.

Control kit AD Corinte A 1 Level 1 FC15M, frequency inverter Product specific accessories, AD Corinte Thermozone AD Corinte E, electrically heated (IP20)
Airflow Heat output [m/h] [kW] ADCH17E*1 0/7.5/15 3000 ADCH22E*1 0/10/20 4000 ADCV22E*2 0/10/20 4000 ADCV25E*2 0/11.2/22.5 4500 *) For horizontal mounting (H= horizontal). *) For vertical mounting (V= vertical). Type Sound level [dB(A)] 40/60 42/61 42/61 43/63

3
Height/ Length [mm] 1700 2200 2200 2450

FC15A, frequency inverter Frequency inverter for variable fan speed control of AD Corinte. Input voltage 230V~, output voltage 3x230V~. Max input inverter 16 A at 230V~ supply voltage. EMC-filter is included as standard. IP20. All settings are pre-programmed for regulation in combination with ADEA. FC15M is similar to FC15A but pre-programmed for manual fan speed control.

ADCFC, filter
Spare filter for single use. Filter class F5 (EU5). Different filter cassettes for each length of AD Corinte.

Control kit AD Corinte E 3 Level 1 ADEA, air curtain control with outdoor sensor, builtin room sensor and door contact ADEAEB, external control board FC15A, frequency inverter

ADCEH, extension hood


Extension hood used to cover the space between the ceiling and the air curtain for a neat finish.

17

Air curtains - Thermozone Entrance

Thermozone SF
For circular and revolving doors with openings up to 4 metres wide. Mounted vertically beside the opening. Curved design that integrates neatly with the door. Extension possible up to 3900 mm (extension without fans). Several optional finishes are available. Depth: 270 mm Width: 560 mm Colour: two-pack coating (any RAL colour) CE compliant.
Type

4m

Thermozone SF W, water heated (IP20). Supply 230V~

Heat output* Airflow Sound level Height [kW] [m/h] [dB(A)] [mm] SF18WL 18 1800 55 2200 SF24WL 23 2400 56 2200 SF36WL 38 3600 57 2200 SF54WL 49 5400 57 2200 *) Applicable at water temperature 80/60 C, air temperature, in +15 C.

Control kit SF W 2 CK02W CB30N, controls the airflow in 3 steps Level 2 RTI2, 2-step room thermostat MDC, magnetic door contact with time relay

Thermozone SF E, electrically heated (IP20). Supply 400V3~


Type SF18E09 SF24E12 SF36E18 SF54E30 Heat output [kW] 0/6/9 0/8/12 0/12/18 0/20/30 Airflow [m/h] 1800 2400 3600 5400 Sound level [dB(A)] 55 56 57 57 Height [mm] 2200 2200 2200 2200

Note! A three-way motor valve with actuator and by-pass valve VKSF (option: VR20/25 or only TVV20/25 with SD20) should be added for a complete control kit.

Accessories - SF E/W
Type Description

Control kit SF E 3 CK02E CB32N, controls the airflow in 3 steps and the heat Level 2 output in 2 steps RTI2, 2-step room thermostat MDC, magnetic door contact with time relay

CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator VKSF Built-in valve set for SF FH25 Flexible hose DN25, L=1 m, 2 pcs SF ext 2500 Extension of unit up to 2500 mm SF ext 3000 Extension of unit up to 3000 mm SF ext 3000+ Extension of unit above 3000 mm SF Powder RAL Powder coating RAL SF Powder NCS Powder coating NCS SF-CrNi-K240 Stainless steel K240 finish SF-CrNi-Br Brushed stainless steel finish SF-CrNi-Ba Polished stainless steel finish SF-CrNi-M8 Mirror polished stainless steel finish More information about accessories on pages 29-31 and 56-58.

18

Air curtains - Thermozone Entrance


A i r cu rt ai ns

Thermozone RD
For circular and revolving doors of all sizes with opening height up to 3 metres. Discreet mounting on top of the revolving door with only the outlet grille visible. The outlet is adapted to fit the revolving door. Several optional finishes are available. Height: 250 mm Depth: 520 mm Colour: two-pack coating (any RAL colour). CE compliant. Thermozone RD W, water heated (IP20). Supply 230V~
Type

3m

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] RD18WL 7.8 1800 48 1000 RD27WL 9.4 2400 49 1000 RD36WL 14.5 3500 50 1500 RD54WL 21.4 5100 51 2000 RD63WL 26.1 6000 52 2500 *) Applicable at water temperature 60/40 C, air temperature, in +20 C.

Control kit RD W 2 CK02W CB30N, controls the airflow in 3 steps Level 2 RTI2, 2-step room thermostat MDC, magnetic door contact with time relay

Thermozone RD E, electrically heated (IP20)


Type RD18E09 RD27E15 RD36E23 RD54E30 RD63E36 Heat output [kW] 0/6/9 0/10/15 0/15/23 0/20/30 0/24/36 Airflow [m/h] 1800 2700 3600 5400 6300

3
Length [mm] 1000 1000 1500 2000 2500

Sound level [dB(A)] 48 49 50 51 52

Note! A three-way motor valve with actuator and by-pass valve VKRD (option: VR20/25 or only TVV20/25 with SD20) should be added for a complete control kit.

Accessories - RD E/W
Type Description

Control kit RD E 3 CK02E CB32N, controls the airflow in 3 steps and the heat Level 2 output in 2 steps RTI2, 2-step room thermostat MDC, magnetic door contact with time relay

CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 MDC Magnetic door contact with time relay, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator VKRD Built-in valve set for RD AFTRD Built-in antigel thermostat for RD FH25 Flexible hose DN25, L=1 m, 2 pcs RD-Powder-RAL Powder coating RAL RD-Powder-NCS Powder coating NCS RD-CrNi-K240 Stainless steel K240 finish RD-CrNi-Br Brushed stainless steel finish RD-CrNi-Ba Polished stainless steel finish RD-CrNi-M8 Mirror polished stainless steel finish More information about accessories on pages 29-31 and 56-58.

19

Air curtains - Entrance

S10 series
The S10 range is BOSSs most popular modular air curtain system. Suitable for offices, shops, reception areas and other commercial premises, the S10 series combines streamlined good looks with high performance and low noise. Modules can be mounted singularly to cover doorways up to 1.5m, or combined to provide a continuous barrier over any width of opening and are suitable for doorways up to 2.7m high. The S10 series is supplied without controls. Remote switching and a control link allow any number of modules to be centrally controlled. High performance is provided by low noise tangential fans connected to powerful twin shaft motors for long service life. Construction is durable white powder coated steel galvanised steel chassis, moulded end caps and brushed aluminium inlet grille.

S15 series
S15 modular air curtains combine the same design characteristics as the S10 range, with higher output for larger commercial applications. Typically S15 units can be mounted up to 4.0m high, but still provide high performance and relatively low noise. S15 units are available in 1.0m and 1.5m modules and like all BOSS modular units can be linked together to form a continuous barrier. Remote switching and a control link allow any number of modules to be centrally controlled. S15 units also use tangential fans coupled to twin-shaft motors for reliability and long service even in the most demanding environments. Construction is durable white powder coated steel galvanised steel chassis, moulded end caps and brushed aluminium inlet grille.

S10 series
Heat output Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] S10-100A 0 1250 53/45 1064 S10-100E 0/4.5/9 1250 53/45 1064 S10-100W 0/8.4* 1150 52/47 1064 S10-150A 0 1900 53/40 1564 S10-150E 0/6.75/13.5 1900 53/40 1564 S10-150W 0/13.2* 1700 48/40 1564 *) Applicable at water temperature 82/71 C, air temperature, in +15 C. Type

S15 series
Heat output Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] S15-100A 0 2400 64/54 1070 S15-100E 0/6/12 2400 64/54 1070 S15-100W 0/18.6* 2200 62/54 1070 S15-150A 0 3600 64/55 1570 S15-150E 0/9/18 3600 64/55 1570 S15-150W 0/27.8* 3300 64/58 1570 *) Applicable at water temperature 82/71 C, air temperature, in +15 C. Type

Accessories
BOSS modular air curtains are supplied without controls, allowing a wide variety of remote switching options and convenient location of the user controls. Typically air curtains are controlled manually using on/off and output switching. This method is suitable where the doorway is continually open or in frequent use. The BOSS range provides a number of control options. Accessories S10/S15
Type CB30N CB32N RTI2 VR20 VR25 MDC SBMS Description Control box (ambient and water heated units) Control box (electrically heated units) 2-step room thermostat, IP44 Valve set, DN 20 mm Valve set, DN 25 mm Door contact Control box for BMS

Standard control boxes Each CB30N (water/ambient unit) or CB32N (electric unit) can be used to control single or multiple units and may be mounted up to 20m from the air curtains. These robust controls allow on/ off, high/low fan speed and high/low output (electric versions only) . Thermostatic control (RTI2) Air curtains may be controlled thermostatically either to switch the unit or the heating elements. Thermostatic control is most suitable where the air curtain is also being used to provide a heating service.

20

Air curtains - Entrance/Industry


A i r cu rt ai ns LP series
The BOSS architectural series has been introduced to meet the needs of architects who require the energy efficiency and comfort benefits of air curtains but also demand units that are in keeping with stylish interior design. The graceful curved profile of BOSSs LP range of air curtains meet the demanding requirements for prestigious locations, such as retailing, corporate head offices, hotels and theatres. Finished in mirror polished (option) or brushed stainless steel (standard finish) these units combine stylish looks with the same high performance and low noise of all other BOSS air curtains. Bespoke manufacture allows some tailoring of the units to meet the requirements of individual locations. In addition to stainless steel, painted finishes can be accommodated, either to a RAL finish or to match a customers sample. You are invited to contact our technical department to discuss specific applications. Architectural air curtains may also be mounted vertically using a special bracket set to provide stylish columns by the entrance door. This option is especially useful in buildings with extensive entrance glazing. Installation height up to 3.5 m. Mirror Polished and RAL colours: POA

S10/15 recessed series


Both S10 and S15 ranges are available as recessed units allowing safe and simple installation in false ceiling voids. In their recessed form S-range air curtains can cover openings up to 2.5m high (S10/R) or 3.7m high (S15/R), and 2m wide. Internally the air curtain components are identical to the standard surface mounted models and are supplied ready fitted in a robust steel mounting frame. The frame can be suspended from a load bearing structure using drop rods or other suitable fixings. The BOSS recessed system is quick and convenient to install as well as being very versatile. The supplied mounting frame ensures that the air curtain components are mounted securely and that safe clearances are maintained around the unit. Each recessed unit comes complete with a flush fitting ceiling grille. No controls are supplied but any of BOSSs remote control options may be used.

S10 recessed series


Heat output Airflow Sound level Length [kW] [m/h] [dB(A)]*2 [mm] S10-100ER 0/4.5/9 1250 53/45 1174 S10-100WR 0/8.4*1 1150 52/47 1174 S10-150ER 0/6.75/13.5 1900 53/40 1674 S10-150WR 0/13.2*1 1700 48/40 1674 S10-200ER 0/9/18 2500 2238 S10-200WR 0/16.8*1 2500 2238 *1) Applicable at water temperature 82/71 C, air temperature, in +15 C. *2) Actual sound level will be influenced by the ceiling void and mounting method. Type

LP series - Brushed stainless steel finish


Heat output Airflow Length [kW] [m/h] [mm] LP-1000ESS 9 1200 1000 LP-1000WSS 10 1200 1000 LP-1500ESS 12 2000 1500 LP-1500WSS 15 2000 1500 LP-2000ESS 18 2500 2000 LP-2000WSS 20 2500 2000 LP-2500ESS 18 3400 2500 LP-2500WSS 20 3400 2500 LP-3000ESS 24 4000 3000 LP-3000WSS 30 4000 3000 *) Applicable at water temperature 82/71 C, air temperature, in +15 C. Type

S15 recessed series


Heat output Airflow Sound level Length [kW] [m/h] [dB(A)]*2 [mm] S15-100ER 0/6/12 2400 64/54 1186 S15-100WR 0/18.6*1 2200 62/54 1186 S15-150ER 0/9/18 3600 64/55 1686 S15-150WR 0/27.8*1 3300 64/58 1686 S15-200ER 0/12/24 4800 2258 S15-200WR 0/37.2*1 4800 2258 *1) Applicable at water temperature 82/71 C, air temperature, in +15 C. *2) Actual sound level will be influenced by the ceiling void and mounting method. Type

Accessories LP
Type LP-NFT LP-ADC LP-TC LP-RT LP-MDC LP-WB15 LP-WB20 LP-CH15 LP-CH20 Description Frost protection D711M Auto door control 2 way blow out temperature control Room thermostat Magnetic door contact Wall brackets 1500 Wall brackets 2000 Covering for hanging 1500 Covering for hanging 2000

See page 20 for range of S10/S15 recessed accessories.

21

Air curtains - Thermozone Industry

Thermozone AD 400 A/E/W


Installation height up to 4 metres Combines high performance with a compact size and an elegant design. Recessed mounting possible. Height: 340 mm Depth: 490 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Thermozone AD 400 W, water heated (IP20)
Type

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AD410W3 29.4 2300 53/62 1025 AD415W3 49.3 3800 39/63 1565 AD420W3 63.8 4800 55/65 2028 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

4m

1 / 1,5 / 2 m

Control kits AD400W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board

Thermozone AD 400 A, ambient, unheated (IP20)


Type AD410A AD415A AD420A Heat output [kW] 0 0 0 Airflow [m/h] 2500 4200 5000

1
Length [mm] 1025 1565 2028

Sound level [dB(A)] 48/63 35/64 50/65

CK03 Level 3

Control kits AD400A 1 Level 1: CB30N, controls the airflow in 3 steps Level 2: CB30N and MDC, magnetic door contact with time relay

*) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit.

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

Thermozone AD 400 E, electrically heated (IP20) Supply 400V3~, control 230V~


Type AD410E14 AD415E20 AD420E27 Heat output [kW] 0/9/13.5 0/13.5/20 0/18/27 Airflow [m/h] 2500 4200 5000

3
Length [mm] 1025 1565 2028

Accessories - AD 400 A/E/W


Type Description

Sound level [dB(A)] 48/63 35/64 50/65

Control kits AD400E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03 Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board

*) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit.

CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAIB Internal control board ADEAGD1 Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 29-31 and 56-58.

22

Air curtains - Thermozone Industry


A i r cu rt ai ns

Thermozone AG 4000 A/E/W


Installation height up to 4 metres. Clean, stylish and simple design. Height: 260 mm Depth: 480 mm Colour: white, RAL 9016. CE compliant. Thermozone AG 4000 W, water heated (IP23)
Type

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AG4010WH 19 2400 49/65 1000 AG4015WH 30 3500 48/66 1500 AG4020WH 47 5100 50/67 2000 AG4025WH 54 6000 51/69 2500 *) Applicable at water temperature 82/71 C, air temperature, in +15 C. 1/1,5/2/2,5m

4m

Thermozone AG 4000 A, ambient, unheated (IP23)


Type AG4010A AG4015A AG4020A AG4025A Heat output [kW] 0 0 0 0 Airflow [m/h] 2700 3800 5400 6300 Sound level [dB(A)] 49/65 48/66 50/67 51/69

1
Length [mm] 1000 1500 2000 2500

Control kits AG4000W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CK03GD Level 3 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Control kits AG4000A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 CB30N and MDC, magnetic door contact with time relay

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

Thermozone AG 4000 E, electrically heated (IP23) Supply 400V3~ and 230V~ (2 supplies required)
Type AG4010E15 AG4015E23 AG4020E30 AG4025E36 Heat output [kW] 0/10/15 0/15/22,5 0/20/30 0/24/36 Airflow [m/h] 2500 3600 5200 6100 Sound level [dB(A)] 49/65 48/66 50/67 51/69

3
Length [mm] 1000 1500 2000 2500

Accessories - AG 4000 A/E/W


Type CK01E CK02E CK03GD CK01W CK02W CB30N CB32N ADEA ADEAEB ADEAIS ADEAGD1 RTI2 RTI2V T10 KRT1900 MDC AGB304 KUR CBT VR20 VR25 TVV20 TVV25 SD20 GWB400 Description

Control kits AG4000E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03GD Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Control kit Electric level 1 (CB32N, RTI2) Control kit Electric level 2 (CB32N, RTI2, MDC) Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) Control kit Water level 1 (CB30N, T10) Control kit Water level 2 (CB30N, RTI2, MDC) Control box (A/W) Control box (E) Air curtain control External control board, IP55 External room sensor, IP30 Additional control board to acheive BMS functionality 2-step room thermostat, IP44 2-step room thermostat with knob, IP44 Room thermostat, IP30 Room thermostat, IP55 Magnetic door contact with time relay, IP44 Door contact, IP44 Digital time switch, IP44 Electronic timer, IP44 Valve set, DN 20 mm Valve set, DN 25 mm 2-way control valve, DN 20 mm 2-way control valve, DN 25 mm Actuator Wall bracket. AG4010/4015 require 2 pcs, AG4020/AG4025 require 3 pcs. More information about accessories on pages 29-31 and 56-58.

23

Air curtains - Thermozone Industry

Thermozone AG 4500/5000 A/W


Installation height up to 5 metres. Clean, stylish and simple design. Height: 450 mm Depth: 750 mm Colour: white, RAL 9016. CE compliant. Accessories - AG 4500/5000 A/W
Type CK01W CK02W CK03GD CB30N CB32N ADEA ADEAEB ADEAIS ADEAGD1 RTI2 RTI2V T10 KRT1900 MDC AGB304 KUR CBT VR20 VR25 TVV20 TVV25 SD20 GWB640 Description

1/1,5/2/2,5m

Thermozone AG 4500/5000 A, ambient, unheated (IP23)


Type AG4515A AG4520A AG4525A AG5010A AG5015A AG5020A AG5025A Heat output [kW] 0 0 0 0 0 0 0 Airflow [m/h] 5300 7600 10200 4700 7100 9300 11600 Sound level [dB(A)] 48/67 50/69 51/70 48/67 50/69 51/70 52/71

Length [mm] 1500 2000 2500 1000 1500 2000 2500

Control kits AG 4500/5000 A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 CB30N and MDC, magnetic door contact with time relay

Control kit Water level 1 (CB30N, T10) Control kit Water level 2 (CB30N, RTI2, MDC) Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) Control box (A/W) Control box (E) Air curtain control External control board, IP55 External room sensor, IP30 Additional control board to acheive BMS functionality 2-step room thermostat, IP44 2-step room thermostat with knob, IP44 Room thermostat, IP30 Room thermostat, IP55 Magnetic door contact with time relay, IP44 Door contact, IP44 Digital time switch, IP44 Electronic timer, IP44 Valve set, DN 20 mm Valve set, DN 25 mm 2-way control valve, DN 20 mm 2-way control valve, DN 25 mm Actuator Wall bracket. AG4510/4515 and AG5010/5015 require 2 pcs. AG4520/AG4525 and AG5020/AG5025 require 3 pcs. More information about accessories on pages 29-31 and 56-58.

Thermozone AG 4500/5000 W, water heated (IP23)


Type

Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AG4515WH 37 4800 48/67 1500 AG4520WH 62 7000 50/69 2000 AG4525WH 82 9400 51/70 2500 AG5010WH 39 4200 48/67 1000 AG5015WH 44 6500 50/69 1500 AG5020WH 70 8500 51/70 2000 AG5025WH 88 10600 52/71 2500 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

Control kits AG 4500/5000 W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CK03GD Level 3 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

24

5m

Air curtains - Thermozone Industry


A i r cu rt ai ns
6m

Thermozone AGV 4000 A/E/W


Floor standing mounting. Installation width up to 4 metres. Mounted on floor consoles (included). Clean, stylish and simple design. Width: 260 mm Depth: 460 mm Colour: white, RAL 9016. CE compliant. Thermozone AGV 4000 W, water heated (IP23)
Type

1,5 / 2 / 2,5 m

Heat output* Airflow Sound level Height [kW] [m/h] [dB(A)] [mm] AGV4015WH 26.9 3500 48/66 1500 AGV4020WH 42.0 5100 50/67 2000 AGV4025WH 48.4 6000 51/69 2500 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

Thermozone AGV 4000 A, ambient, unheated (IP23)


Type AGV4015A AGV4020A AGV4025A Heat output [kW] 0 0 0 Airflow [m/h] 3800 5400 6300 Sound level [dB(A)] 48/66 50/67 51/69

1
Height [mm] 1500 2000 2500

Control kits AGV4000 W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CK03GD Level 3 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

Control kits AGV4000 A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 CB30N and MDC, magnetic door contact with time relay

Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit.

Thermozone AGV 4000 E, electrically heated (IP23) Supply 400V3~ and 230V~ (2 supplies required)
Type AGV4015E AGV4020E AGV4025E Heat output [kW] 0/15/22.5 0/20/30 0/24/36 Airflow [m/h] 3600 5200 6100 Sound level [dB(A)] 48/66 50/67 51/69

3
Height [mm] 1500 2000 2500

Accessories - AG 4000 A/E/W


Type Description

Control kits AG4000E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK03GD Level 3 CB32N, RTI2 and MDC, magnetic door contact with time relay ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board

CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03GD Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator GWB400* Wall bracket AXP300 Collision protection *) Wall bracket GWB400 can be used to fix the unit to the wall or the ceiling. More information about accessories on pages 29-31 and 56-58.

25

Air curtains - Thermozone Industry

Thermozone AC 500
Installation height 3 - 6 metres. Can also be mounted vertically. Without heat. Height: 785 mm Depth: 520 mm Colour: white, RAL 9016. CE compliant.

Thermozone AC 600
Thermozone AC600 consists of a pillar with inlet hood, silencers and fans, as well as a floor channel with its slot at floor level. It is placed inside and next to the door opening. Air at high speed is pressed out through the narrow slot in the floor inside the door opening. The width of the slot and the blow angle are adapted to the opening. Complete slot with inspection hatch could be custom made. AC600 creates a very effective air barrier inside the the door opening, when pressing air at high speed out through a narrow slot. The air curtain is angled upwards and gives best possible protection against colder and heavier air getting into the building. Colour: grey. CE compliant. Thermozone AC 600, ambient, unheated (IP24)

3-6 m

1 / 1,5 m

Thermozone AC 500, ambient, unheated (IP24)


Type Heat output [kW] [V] 230V~/400V3~ 0 230V~/400V3~ 0 Voltage Airflow [m/h] 5200 7700

1
Length [mm] 1030 1550

AC501 AC502

Sound level [dB(A)] 63 65

8m

1
Sound level [dB(A)] 66 83 85 74 86

Control kits AC500 1 Level 1: AGB304, door contact, starts/stops the air curtain when the door is opened/closed RTRD7, RTRD14, 5-step fan speed control Level 2: AGB304 and PKDM12, stepless fan speed control, high/low speed

Type

Voltage [V] 400V3~ 400V3~ 400V3~ 400V3~ 400V3~

AC601 AC602 AC603 AC601X AC602X

Motor output [kW] 5.5 11 (2x5,5) 15 7.5 15 (2x7,5)

Airflow [m/h] 10800 13400 14700 15500 18000

Accessories - AC 500
Type Description

Accessories - AC 600
Type Description

RTRD7 5-step fan speed control, Max 7 A RTRD14 5-step fan speed control, Max 14 A RTRDU7 5-step fan speed control, high/low speed PKDM12 Stepless fan speed control, high/low speed AGB304 Door contact, IP44 More information about accessories on pages 29-31 and below.

MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 ACR60x Start equipment More information about accessories on pages 29-31.

Product specific accessories, AC 600


ACR600, control box Control box with start/stop and indication lamp for each fan. Time delay between the motors when starting. Possible to connect door contact (AGB304). Built-in motor protection for each fan.

Product specific accessories, AC 500


PKDM12, 3-phase stepless fan speed control The appropriate fan speed is set for open and closed door respectively (high/low speed). The fan speed can be controlled with an external 010 V signal. Max input 12 A. IP54.

26

Air curtains - Thermozone Industry


A i r cu rt ai ns

Thermozone AGI A/W


Thermozone AGI is a robust air curtain for industrial doors that can be mounted horizontally or vertically. Four module lengths means you can easily combine the curtains to cover the individual needs of every door. An adjustable air blower grille allows you to direct the airflow to achieve an optimal air curtain effect. Width: 730 mm Depth: 490 mm Colour: grey, RAL 9006. All units have 400 V3~ supply. CE compliant. Thermozone AGI A, ambient, unheated, vertical mounting, (IP23) 1
Type AGIV2A AGIV3A AGIV4A AGIV5A Heat output [kW] 0 0 0 0 Airflow [m/h] 7000 10500 14000 17500 Sound level [dB(A)] 69 71 72 73 Height [mm] 1200 1800 2400 3000

1,2 / 1,8 / 2,4 / 3,0 m

Thermozone AGI W, water heated, vertical mounting, (IP23)


Type

1,2 / 1,8 / 2,4 / 3,0 m

Heat output* Airflow Sound level Height [kW] [m/h] [dB(A)] [mm] AGIV2WL 48.7 7000 69 1200 AGIV3WL 75.8 10500 71 1800 AGIV4WL 104.2 14000 72 2400 AGIV5WL 130.2 17500 73 3000 *) Applicable at water temperature 82/71 C, air temperature, in +15 C.

Thermozone AGI W, water heated, horizontal mounting, (IP23) 2


Heat output* Airflow Sound level Length [kW] [m/h] [dB(A)] [mm] AGIH2WL 43.8 7000 69 1200 AGIH3WL 68.2 10500 71 1800 AGIH4WL 93.8 14000 72 2400 AGIH5WL 117.2 17500 73 3000 *) Applicable at water temperature 82/71 C, air temperature, in +15 C. Type

Thermozone AGI A, ambient, unheated, horizontal mounting, (IP23) 1


Type AGIH2A AGIH3A AGIH4A AGIH5A Heat output [kW] 0 0 0 0 Airflow [m/h] 7000 10500 14000 17500 Sound level [dB(A)] 69 71 72 73 Length [mm] 1200 1800 2400 3000

Control kits AGI W 2 Level 1 RTRD7, RTRD14, 5-step fan speed control T10, room thermostat Level 2 RTRD, T10 and MDC, magnetic door contact with time relay

Accessories - AGI A/W Control kits AGI A 1 Level 1 AGB304, door contact, starts/stops the air curtain when the door is opened/closed RTRD7, RTRD14, 5-step fan speed control
Type Description

RTRD7 5-step fan speed control, Max 7 A RTRD14 5-step fan speed control, Max 14 A RTRDU7 5-step fan speed control, high/low speed T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP44 CBT Electronic timer, IP44 More information about accessories on pages 29-31 and 56-58.

27

Air curtains - Thermozone Cold storage


Our cool models

Frico offers several models without heat that are suitable for keeping the cold in cold storages. Choose the appropriate unit according to the dimensions of the opening. There are units for horizontal and vertical mounting and in different designs.

Thermozone ADA Cool


For cold storage openings. Installation height up to 2,5 metres. Suitable where space is limited between the ceiling and the upper edge of the doorway. With cable and plug. Should be mounted on the outside (warm side). ADAC has a simple connection making it possible to link units together in order to cover wide openings such as open cold storages. All connections are done with cable and plug, including the control. Recessed mounting possible. Height: 235 mm Depth: 215 mm Colour: white, RAL 9016. CE compliant.

Installation height up to 2,5 m


ADA Cool

2,5 m

AD 200 A Horizontal mounting Lengths: 1, 1.5 and 2 metres.

AD 200

Installation height up to 3,5 m


0,9 / 1,2 m

AD 300 A Horizontal mounting Lengths: 1, 1.5 and 2 metres.


AD 300 / 400

Installation height up to 4 m
Thermozone ADA Cool, ambient, unheated (IP22)
Type Voltage [V] 230V~ 230V~ Heat output [kW] 0 0 Airflow [m/h] 1120 1450

1
Length [mm] 900 1200

ADAC090 ADAC120

Sound level [dB(A)] 59 59

AD 400 A Horizontal mounting Lengths: 1, 1.5 and 2 metres.


AG 4000 / 4500 / 5000

Installation height up to 4,5 m


AG 4000 A Horizontal mounting Lengths: 1, 1.5, 2 and 2.5 metres.

Accessories - ADA Cool


Type ADACR Description 5-step fan speed control

Installation height up to 5 m
AG 4500 A and AG 5000 A Horizontal mounting Lengths: 1, 1.5, 2 and 2.5 metres.
AGV

Product specific accessories, ADA Cool


ADACR, 5-step fan speed control ADACR is a control and connection set consisting of a 5-step fan speed control, flexible cable and earthed plug. Can control a maximum of 7-9 units (max. 7 units at 60 Hz). Max input: 5 A. Dimensions: 200x105x105 mm. IP30.

2,2 m

ADACR 5A

Installation width up to 4 m
AGV 4000 A Vertical mounting Heights: 1.5, 2 and 2.5 metres.

2,2 m

Large entrances
AGI Vertical or horizontal mounting Heights/ Length: 1.2, 1.8, 2.4 and 3 metres.

AGI

28

Air curtains - Thermozone controls


ADEA Air conditioner control ADEAR, air curtain control with display unit and built-in room sensor ADEAOS, outdoor sensor MDCDC, magnetic door contact Building Management System Elevator control Fire alarm system Entrance control

Air curtain control

ADEAIB, internal control board, for AD300/400

ADEAIS, external room sensor

ADEAEB, external control board

SBMS, BMS control level 1

ADEA, air curtain control


ADEA is an advanced and user friendly control for air curtains. ADEA is ready to run directly after installation on account of the pre-programmed parameters. An outdoor sensor, room sensor and door contact govern the control, which adapts the heat and fan speed, according to the preset parameters, to the prevailing conditions. In its basic design the fan speed is controlled in 3 stages, but can, via a 0-10V signal, govern an external controller (ADSR54 or frequency inverter) to provide fully variable control. A control board needs to be added, ADEAIB for internal mounting (for AD300/400 only) or ADEAEB (IP55) for external mounting (for all units). Depending on the motor current, one or more units may be controlled with one control board. An extra control board ADEAGD1 is needed to control AG, AGV, ACC, RD and ADR air curtains. The control board also makes it possible to connect any Frico air curtain running with ADEA to an advanced BMS system. The extra control board is mounted on the ADEAB control board. One ADEA is needed for each opening, but it can control several air curtains.

Integrating air curtains AD200400 to a BMS system BMS control - level 1


The SBMS control box is used for connecting an AD200-400 air curtain to a Building Management System. The SBMS has a 24 V AC relay for on/off signals and a volt free alarm signal. Protection class IP44.

BMS control - level 2


Integrating AD200-400 air curtains to a Building Management System with ADEAEB/IB. Use the air curtain as an integral part of the buildings climate system by operating fan speed and heat output with the BMS. Includes an alarm signal for the fan motor (only AD300/400) and possibilities to guide the air curtains operations with a door contact. The level 2 solution requires 010 V signals to control fan speed and heat output.

BMS control - level 3


Advanced integration of AD200-400 air curtains to a Building Management System with ADEAEB and ADEAGD. Use the air curtain as an integral part of the buildings climate system. Manages on/off, fan speed, and heat output operations. The level 3 solution also gives indications of current running mode: on/off, fan speed, heat output and alarm signal. Includes possibilities to guide the air curtain operations with a door contact. The level 3 solution requires 010 V signals to control fan speed and heat output.

For BMS control of other air curtains, please contact Frico.

Type

Description

AD Corinte

AD 200/300/400*1

Portier

ADR

AG 4000 AG 4500/5000 AGV 4000 W X X X X X* A E X X X X X* W X X X X X *

A ADEA ADEAOS ADEAEB ADEAIB ADEAIS ADEAGD1 Air curtain control Outdoor sensor External control board Internal control board External room sensor Extra control board for ADEAEB, BMS

E X X X X X

W X X X X X

E X X X X* X X

W X X X X * X X X

E X X X X X

E X X X X X*

SBMS Control box for BMS *) only for AD300/400. *) ADEAGD1 is required when ADEA is used with these products.

29

A i r cu rt ai ns

Air curtains - Thermozone Fan speed controls

CB32N

CB30N

ADSR54

RTRD7

RTRD14

RTRDU7

MDC

MDCDC

AGB304

CB32N, control box


For AD E, AG E, ADR E and RD E. Controls the airflow in 3 steps and heat output in 2 steps. CB32N is used for electrically heated units. Can control several units. Max input 10 A. IP44.

RTRDU7, 5-step fan speed control (high/low speed)


For AC500 and AGI. With RTRDU7 the air velocity is set in 5 steps for maximum efficiency. When the door is closed the fan runs at a preset low speed to keep the room warm, when the door is open the fan is preset at a high speed to accommodate different external conditions. Max input 7 A. IP21.

CB30N, control box


For AD A/W, AG A/W, ADR W and RD W. Controls the airflow in 3 steps. CB30N is used for unheated and water heated units. Can control several units. Max input 10 A. IP44.

MDC, magnetic door contact with time relay


Starts the air curtain or increases from low to high speed when the door is opened. When the door is closed, the fan continues to run for the preset time (2 s10 min). Prevents the fan from starting/stopping continuously and is especially suitable for doors that are frequently opened. Three alternating volt-free contacts 10 A, 230 V~. Is activated by a volt-free make. A MDCDC is included in MDC. IP44.

ADSR54, stepless fan speed control


For AD200/300/400 A/W. For unheated and water heated air curtains (single phase supply 230 V~, max 3 A). Controls the motor without causing disturbing electro magnetic noise. Can be controlled with an external 010 V signal. Max. input 3 A, 230 V~. IP54.

MDCDC, magnetic door contact


Indicates door status. Extra MDCDC are used when several doors are connected to a MDC. IP44.

RTRD7, 5-step fan speed control


For AC500 and AGI. With RTRD7 the air velocity is adjusted in 5 steps for optimum efficiency. The air velocity is set to accommodate different external conditions. Max input 7 A. IP21.

AGB304, door contact


Starts the air curtain or activates a fan speed control when the door is opened. When the door closes, AGB304 stops the air curtain or changes fan speed through a fan speed control. Alternating contact 4 A, 230 V~. IP44.

RTRD14, 5-step fan speed control


For AC500 and AGI. With RTRD14 the air velocity is adjusted in 5 steps for optimum efficiency. The air velocity is set to accommodate different external conditions. Max input 14 A. IP21.

AD Corinte*

AD 200/300/400

Portier

AR200

SF, RD ADR E X W X

AG4000 AG4500/5000 AGV4000 A X X E W X

AC500

AGI

AC600*

A CB30N CB32N CB22 ADSR54 RTRD7 RTRD14 RTRDU7 MDC X

A X

E X

W X

E X

X X* X* X X X X X X X X X X X X X X X X X X X X X X X X X X X

AGB304 *) These air curtains have their controls described on their product page. *) Max.input 3 A.

30

Air curtains - Thermozone accessories


ADPK1 ADPF
4x

2x

22003, 22004

GWB

AXP300

22003, 22004, false ceiling grille


Primarily used as air inlet grille when the air curtain is recessed into a false ceiling. Available in two sizes; 1192x192 mm and 1515x192 mm. Colour: white.

GWB, wall bracket


For AG4000/4500/5000. GWB400 is used for AG4000 and GWB640 is used for AG4500/5000. 2 brackets are needed for units up to 1,5 metres and 3 brackets are needed for 2 and 2,5 metre units. The brackets are screwed into place in the wall. The air curtain is then suspended from the brackets using threaded bars. Can also be used for AGV4000 to fix the unit to the wall or the ceiling. Zinc plated.

ADPK1, suspension kit


For AD200/300/400. Mounting kit for suspension mounting of the AD-range. Consists of 2 hanging brackets, length 1 metre, and 4 bracket fixtures (2 for the unit and 2 for the ceiling). The hanging brackets are covered by a white plastic trim to cover the cables. The brackets may be cut to shorter length, if required. Note! The 2-metres AD-units need 3 fixing points. Colour: white.

AXP300, collision protection


AXP300 is mounted on the ground next to a vertical air curtain to prevent it from being hit by trucks, shopping trolleys and similar. Colour: metal grey.

ADPF1, suspension brackets


For AD200/300/400. Suspension brackets for the AD-range. Consists of 4 brackets (2 for the unit and 2 for the ceiling). Note! The 2-metres long AD-units need 3 fixing points. Colour: white.

AD Corinte A 22003 22004 ADPK1 ADPF1 GWB400 GWB640 AXP300 X X X E W

AD 200/300/400 A X X X X E X X X X W X X X X

Portier E A

AG4000 E W

AG4500/5000 A E W A

AGV4000 E W A

AGI W

X X X X X X X X X X X X X

31

A i r cu rt ai ns

Radiant heaters
Heating with radiant heaters is indirect. The heat is transferred from the radiant heaters at the ceiling to surfaces such as floors, walls, fixtures and the like, which in their turn give off heat to the air in the room. No losses occur on the way from ceiling to floor. Radiant heating can be compared to ordinary light. Dispersion and reflection occur in relatively the same way. Radiant heaters create a very equal temperature distribution between floor and ceiling. The expensive cushion of overheated air that is easily formed when using other heating systems can be avoided. In rooms with high ceilings, radiant heaters give significantly lower energy consumption. Total heating Radiant heaters heat people first, then the air. The operative temperature, being the temperature a person senses, is therefore a little higher than the actual air temperature. For a specific comfort level, use of a radiant heating system will allow a reduction in air temperature of a couple of degrees when compared to a conventional system, and every degree reduction will reduce energy consumption by approx. 5 %. Zone and spot heating With a radiant heating system, different zones within the same room can have different temperatures. It is therefore possible to divide any area into smaller zones and maintain a different comfort level in each zone. It is also possible to focus the heat on a certain spot, such as a single workstation. A spot heating application can be controlled much as spot lighting, with the level of heating being increased when needed. Complementary heating As addition to other heating systems and when expanding an existing system, radiant heaters are often a simple, inexpensive solution. For a water heated building, putting up a single or a few electrical heaters is often a smoother and more flexible solution than extending the water pipe system. Cold draught protection A cool surface such as a window has a chilling effect on the neighbouring air. Radiant heaters provide efficient and economical protection against cold draughts caused by windows by heating the windows surface. The colder the window, the more radiant heat it will draw. The radiated heat automatically migrates to where it is most needed, which facilitates the creation of a comfortable indoor climate.

32

Radiant heaters
There are many advantages with radiant heaters:
Economy

Heat people and objects first and then the surrounding air. This allows the temperature to be reduced while maintaining comfort. Produces instant heat, thus much quicker than traditional heating systems. This is especially useful outdoor and in buildings that is used occasionally such as sport centres and country houses. Heat at floor level, not at the ceiling. Radi an t h e a t e r s
33

Reduced night temperture possible with right controls thanks to quick heat-up time.
Safety

By positioning the heaters at high level the risk of getting in contact with the heater is greatly reduced. The heater is also protected against damage. Some radiant heaters are ideal for premises with fire risk or highly explosive environments (see radiant heaters SZ and SZR).
Simplicity

Easy and flexible installation. Requires a minimum of maintenance.


Space

By putting the heater on the ceiling, valuable wall and floor space is saved.
Comfort

Using the radiation principle air is not heated directly. This results in a soft, draught-free, comfortable indoor climate and an even temperature. Does not cause any air movement, as traditional heating systems often do. Reducing the spread of dust, bacteria or odours improves the quality of the indoor environment.
Discreet

The system is completely silent. Mounting on the ceiling or recessed in a false ceiling gives a discreet heating.

Choose the right radiant heater


Radiant heaters are available in various designs it is primarily the installation height, the surrounding environment and the type of heating wanted (see page 32) that determine the choice of product. Our radiant heaters are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and "Outdoors" but most of them can be used in several application areas as you can see in below table. Comfort To acheive good comfort, it is essential to choose the right type of radiant heater. An infrared heater equipped with halogen lamps at approx. 2000 C provides intense, short-wave radiation. It is well-suited to outdoor use or in rooms with high ceilings. For a similar but softer heat an infrared heater with tube elements at approx. 750 C can be used. The heat emitted from these radiant heaters can be compared to the radiant heat felt from an open fireplace. A Thermocassette with a large element surface and a surface temperature of approx. 100 C, provides longwave heat radiation, giving comfortable heating and good dispersion in rooms of normal height (2,7 m). In a building with high demands on comfort, a larger number of heaters with low output should be used instead of fewer heaters with high output. When zone- or spot heating an area, the heaters should be placed so that the heat comes from at least two directions. This is especially important when the heaters are mounted at lower heights. Below table and the examples on the following pages will help you to choose the right radiant heater.

Quick selection guide radiant heaters


Type Heating Installation height [m] Comfort panel SZR Comfort panel SZ Thermoplus Thermocassette Elztrip EZ100 Elztrip EZ200 Elztrip EZ300 Infrared IR Infrared IRCF Infrared IH Infrared CIR 2,510 315 23 <3 2,54 310 412 4,520 35 1,83,5 22,5 Output [W] 100-580*2 50-1900*2 300-900 300-600 600-1500 800-2200 3600 3000-6000 1500-4500 1000-2000 500-2000 Surface temp. [C] 80 80 180 100 280 340 350 700 2200*3 2200*3 750 ++ ++ ++ ++ ++ + + + ++ ++ ++ ++ + + + + ++ ++ Application area*1 Offices Industry Outdoors Radiant steel panel Radiant steel panel Radiant aluminium panel Heating film Radiant aluminium panel Radiant aluminium panel Radiant aluminium panel Infrared heating rod Halogen lamp Halogen lamp Infrared heating rod 36 37 38 38 39 39 40 40 41 41 42 42 Heating element Page

23 1200-1800 2200*3 + ++ Halogen lamp Infrared ELIR *1) Our products are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and "Outdoors" but most products can be used in several application areas. *2) Per metre, depending on water temperature. *3) Filament temperature

2 2 3 3 3 3 3 3 3 3 3 3

34

Installation examples for radiant heaters


Frico radiant heaters are available for different kind of heating and for different application areas. To facilitate your choice of product, you will find some typical cases on the following pages. More detailed information on important factors to consider when choosing a radiant heater is found on the previous pages. Basic criterias: 1. Type of premises store, warehouse etc. 2. Type of heating - total heating, zone heating, cold draught protection 3. Height, installation height 4. Mounting: wall or ceiling 5. Connection: with electrical heat or water heat

Offices, shops and public premises


Total heating, cafeteria 1. Type of premises: cafeteria 2. Type of heating: total heating 3. Height: 2,80 metres 4. Mounting: ceiling 5. Connection: electrical Recommendation: Thermocassette can be recessed into a false ceiling. When using Thermocassette for total heating, the units should be spread out through the ceiling for example as shown. Radi an t h e a t e r s
35

Industry
Total heating, workshop 1. Type of premises: workshop 2. Type of heating: total heating 3. Height: 5 metres 4. Mounting: ceiling 5. Connection: with electrical heat Recommendation: A number of EZ300 evenly positioned over the area to be heated creates comfortable heat.

Outdoors
Zone heating, restaurant terrace 1. Type of premises: restaurant terrace 2. Type of heating: zone heating 3. Height: 3 metres 4. Mounting: ceiling (above the tables) 5. Connection: with electrical heat Recommendation: Several CIR mounted in line above the tables ensure the comfort for all customers in deep terraces.

Radiant heaters - Offices, shops and public premises

Comfort Panel SZR recessed, water heated


Comfort Panel SZR is used for water supplied heating/cooling systems. It is primarily intended for mounting in false ceilings and perfectly suits 2,5 - 10 m in fine environments such as offices, shops, etc, but can also be mounted free hanging. Discreet flat satin finished surface with very discreet countersinks. The satin finished surface matches most false ceiling panel designs. A perfect symmetri can be created with heating/cooling panels in combination with neutral panels. Complies to EN14037 which is based on the EU Construction Product Directives 89/106/CEE. EN14037 is compulsory for a CE mark for water heated radiant heaters. Max working pressure: 4 bar. Max water temperature: 90 C Colour: Epoxy-polyester coating in RAL 9010 (white) as standard. Comfort Panel SZR
Type*1

Heat output*2 Weight LxHxW [W/pcs] [kg] [mm] SZR120 355 14 1186x35x586 SZR180 534 21 1786x35x586 SZR240 713 28 2386x35x586 SZR300 893 35 2986x35x586 SZRN60 Neutral 4 586x35x586 SZRN120 Neutral 8 1186x35x586 *1) Panels delivered without male threaded connections are available as SZRCxxx *2) Applicable at water temperature 80/60 C, air temperature +20 C.

Insulation 30 mm (included, not mounted) Suspension

Accessories - Comfort Panel SZR


Type Description Insulation holding strip

T10 Room thermostat, IP30 TVV20/25 2-way control valve, DN 20/25 mm SD20 Actuator TRV20/25 3-way control valve, DN 20/25 mm Suspension accessories are priced on request.

Suspension
Comfort Panel SZR may be installed in several different ways using the supporting structure of the ceiling.

3/4 male threaded connection (included, not mounted). Flat pipe end 22 mm

Construction
The Comfort Panel SZR radiant panels are made of a 1 mm thick galvanized steel plate. A 1 mm thick oblong-shaped copper tube is fixed to the panel. A galvanized cover plate is welded to the panel in order to hold the pipe in place and to secure the best surface contact between the pipe and the panel. An insulating layer of mineral wool (30 mm thick) protected by an aluminium sheet (25 micron thick) is supplied with SZR to be mounted on the top of the panel.
Wood Concrete Concrete

A Comfort Panel with detailed information is available at www.frico.se. Further information can also be obtained by contacting Frico. 36

Radiant heaters - Industry and large premises

Comfort Panel SZ, water heated


Comfort Panel SZ is the ideal system solution for heating of larger buildings such as industrial buildings, commercial buildings and sports 3 - 15 m centres. Comfort Panel SZ is suitable for both high and low installation, and extremely high installations are possible with pressurized hot water. Elegant design in white or grey. Other colours available on request to match the premises. Complies to EN14037 which is based on the EU Construction Products Directives 89/106/CEE. EN14037 is compulsory for a CE mark for water heated radiant heaters. Max working pressure: 10 bar (special version: 16 bar) Max water temperature: 120 C (special version: 180 C) Colour: white, RAL 9010 or light grey, RAL 9002. Other colours available on request.

Comfort Panel SZ max 120 C


Type

Heat output* Weight Width [W/m] [kg/m] [mm] SZ23 162 4 300 SZ26 289 8 600 SZ29 406 12 900 SZ212 543 16 1200 SZ33 194 6 300 SZ36 345 12 600 SZ39 501 18 900 SZ312 639 24 1200 *) Applicable at water temperature 80/60 C, air temperature +15 C.

Comfort Panel SZ special max 180 C


Type

Heat output* Weight Width [W/m] [kg/m] [mm] SZ23SP 267 5 300 SZ26SP 477 10 600 SZ29SP 667 15 900 SZ212SP 870 20 1200 SZ33SP 324 7 300 SZ36SP 574 14 600 SZ39SP 790 21 900 SZ312SP 1005 28 1200 *) Applicable at water temperature 130/70 C, air temperature +15 C.

Construction
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Threaded male connection ( 1/2 - 3/4 - 1 - 1.1/4) Connection for drain valve 3/8 Connection for air vent. valve 3/8 First or end header Steel pipe 1/2 Radiant panel Suspension bracket Insulation Side edging strip Insulation retaining clip Anti-convective side skirts (accessory) Skirt hook Pipe ends adapted for press fitting or compression fitting or belled end for welding 14. Make-up joint 15. Make-up joint between panel and header (accessory)

Accessories - see Comfort Panel SZR

Suspension
SZ panels can be mounted horizontally, vertically or in an angle. The suspensions are not supplied with the radiant panels, and must be provided by the customer or ordered separately. These can be made using threaded rods, chains or perforated brackets, and they must be adjustable. The length of the suspensions must be proportional to the total thermal expansion of the radiant panel.

A Comfort Panel catalogue with detailed information is available at www.frico.se. Further information can also be obtained by contacting Frico. 37

>L

Radi an t h e a t e r s

Radiant heaters - Offices, shops and public premises

Thermoplus
Thermoplus is mounted above windows and gives an efficient protection against cold draught. The slim shape also makes it suitable 2-3m for heating areas with limited space, like for example bathrooms. It can furthermore be a cost-effective and flexible alternative to floor heating. A front panel of white enamelled aluminium makes it scratch-resistant and discreet. The slim shape makes it practically invisible when mounted in the ceiling angle. Brackets for wall mounting are included. Fixtures for ceiling mounting are extra. Type EC, for dry rooms. Controlled by a separate thermostat or output control. Type ECVT, for wet rooms. With a built-in cord switch and thermostat. Type ECV, for wet rooms. Primarily designed for connection as slave device to ECVT, but can also be controlled separately using the same methods as for EC. Same technical data as for ECVT but 0,3 kg lighter. Max. surface temperature: 180 C. Colour: white, RAL9010. CE compliant.

Thermocassette HP
Thermocassette is intended for discreet heating in offices, bathrooms, schools etc. Designed for either surface or recessed mounting it <3m is well suited for total heating as well as for spot heating of for example a reception desk. Mounted in a false ceiling it is well protected against damage and can easily be moved if necessary (model with cable and plug). Recessed mounting makes the heater an integral part of the ceiling. The low surface temperature (max. 100 C) makes Thermocassette well suited for low ceiling heights. There is no risk of burns to person(s) in the vicinity. Type HP300/600, for false ceiling systems. Type HP305/605, standard model with brackets, approved for use in rooms where there is an increased risk of fire and recommended for use in agricultural buildings. Max. surface temperature: 100 C. Colour: white, RAL 9016. CE compliant. HP305/605 are approved for use in rooms where there is an increased risk of fire and is recommended for use in agricultural buildings.

Thermoplus EC for dry rooms (IP20)


Type EC45021 EC45031 EC60021 EC60031 EC75021 EC75031 EC90021 EC90031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ 230V~ 400V~

3
LxHxD [mm] 1076x100x90 1076x100x90 1505x100x90 1505x100x90 1810x100x90 1810x100x90 2140x100x90 2140x100x90 Weight [kg] 2,6 2,6 3,7 3,7 4,4 4,4 4,8 4,8

Thermocassette HP for false ceilings, with cable and plug (IP20) 3


Type HP300 HP600 Voltage [V] 230V~ 230V~ Heat output [W] 300 600 LxHxD [mm] 593x30x593 593x30x1193 Weight [kg] 5,4 10,3

Heat output [W] 450 450 600 600 750 750 900 900

Thermocassette HP with mounting brackets and cable (IP55)


Voltage [V] HP305 230V~ HP605 230V~ *) Height with brackets Type Heat output [W] 300 600 LxHxD [mm] 593x80*x593 593x80*x1193

Thermoplus ECV(T) for wet rooms (IP44)


Type ECV(T)30021 ECV(T)55021 ECV(T)55031 ECV(T)70021 ECV(T)70031 Voltage [V] 230V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 550 550 700 700

3
LxHxD [mm] 870x100x90 1505x100x90 1505x100x90 1810x100x90 1810x100x90 Weight [kg] 2,6 4,3 4,3 5,0 5,0

Weight [kg] 5,8 10,7

Accessories - Thermocassette
Type Description

Accessories - Thermoplus
Type Description

TF1 Fixtures for ceiling mounting (2 pcs) OS1 Protection net 1070 mm OS2 Protection net 1500 mm For controls, see Thermocassette and pages 52-53.

ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 KRT1900 Room thermostat, IP55 SKB10 Shelter bars 74701 Wire mounting kit For controls, see pages 43 and 56-57.

Min. distances EC [mm]


Type Ceiling Wall / long side of the unit (EC) Flammable material/ front side (EC) Flammable material/ lower side (EC) Floor A B C D E EC 60 25 90 25 1800

Min. distances HP [mm]


Type Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor HP 80 50 50 500 1800 50 500 1800 80

38

Radiant heaters - Offices, shops and public premises

Elztrip EZ 100
EZ100 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments such as offices, shops etc. 2,5 - 4 m Clean and simple design that blends well with electrical fittings. Surface structure that gives optimal efficiency. Fixtures for easy mounting on the ceiling are included. Bracket for wall mounting (EZMVK) is available as an accessory. The heaters are approved for serial connection. Max. surface temperature: 280 C. Colour: white, RAL 9016. CE compliant.

Elztrip EZ 200
EZ200 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments such as restaurants, department stores, assembly 3 - 10 m halls etc. Clean and simple design that blends well with electrical fittings. Surface structure that gives optimal efficiency. Fixtures for easy mounting on the ceiling are included. The heaters are suitable for serial connection. Max. surface temperature: 340 C. Colour: white, RAL 9016. CE compliant.

Elztrip EZ 100 (IP44)


Type EZ106 EZ111 EZ115

3
Heat output [W] 600 1050 1500 LxHxD [mm] 1000x50x150 1500x50x150 2000x50x150 Weight [kg] 3,7 5,4 7,8

Elztrip EZ 200 (IP44)


Type EZ208 EZ212 EZ217 EZ222 EZ20831 EZ21231 EZ21731 EZ22231

3
Heat output [W] 800 1200 1700 2200 800 1200 1700 2200 LxHxD [mm] 683x64x282 923x64x282 1221x64x282 1520x64x282 683x64x282 923x64x282 1221x64x282 1520x64x282 Weight [kg] 4,9 6,8 8,8 10,7 4,9 6,8 8,8 10,7

Voltage [V] 230V~ 230V~ 230V~

Accessories - EZ 100
Type Description

Voltage [V] 230V~ 230V~ 230V~ 230V~ 400V2~ 400V2~ 400V2~ 400V2~

ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 CIRT Stepless output control with timer, IP44 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 EZMVK Wall mounting bracket For controls, see pages 43 and 56-57.

Accessories - EZ 200
Type Description

ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 CIRT Stepless output control with timer, IP44 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 For controls, see pages 43 and 56-57.

Min. distances EZ 100 [mm]


Type Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E EZ100 50 50 50 500 1800
B A C D E

Min. distances EZ 200 [mm]


Type Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E EZ200 80 150 150 600 1800
B A C D E

39

Radi an t h e a t e r s

Radiant heaters - Industry and large premises

Elztrip EZ 300
EZ300 is intended for total and supplementary heating in industrial environments such as warehouses, workshops etc. Discreet and robust design that blends well 4 - 12 m with electrical fittings. Surface structure that gives optimal efficiency. Fixtures for easy mounting on the ceiling are included. The heaters are approved for serial connection. Max. surface temperature: 350 C. Colour: Casing of grey alu-zinc coated steel panels with high corrosion resistance. Heating panel of naturally anodized aluminium. CE compliant.

Industrial infrared heater IR


IR is suitable for total or supplementary heating of premises with large volume and high ceilings. It can also be used outdoors for example on sport arena stands or to keep loading bays dry 4,5 - 20m and frostfree. Robust industrial design. Reflectors of highgloss polished aluminium for optimal heat distribution. The mounting hinges allow the heater to be angled in five different positions. Protection grille is available as an accessory. Max. element temperature: 700 C. Colour: grey aluminium zinc coated steel panels with high corrosion resistance. CE compliant.

Industrial infrared heater IR (IP44) Elztrip EZ 300 (IP44)


Type EZ336

3
LxHxD [mm] 1670x63x420 Weight [kg] 19,8

Voltage Heat output [V] [W] 230V3~/400V3~ 3600

Elztrip EZF42 (IP44)


Type EZF42 Voltage [V] 400V3~

3
Heat output [W] 4200 LxHxD [mm] 1760x67x400 Weight [kg] 20,0

Voltage Heat output LxHxD Weight [V] [W] [mm] [kg] IR3000 400V3N~* 1000/2000/3000 1125x83x358 9,0 IR4500 400V3N~* 1500/3000/4500 1500x83x358 11,1 IR6000 400V3N~* 2000/4000/6000 1875x83x358 13,2 *) Can be connected without neutral, but then without output steps. With neutral, one elements at a time can be connected.

Type

Accessories - Industrial infrared heater IR


Type Description

Accessories - EZ 300
Type Description

S123 Manual switch for 1-2-3 steps, IP42 T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 CBT Electronic timer, IP44 For controls, see pages 43 and 56-57.

S123 Manual switch for 1-2-3 steps, IP42 T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 CBT Electronic timer, IP44 IRG3000 Protection grille IR3000 IRG4500 Protection grille IR4500 IRG6000 Protection grille IR6000 For controls, see pages 43 and 56-57.

Min. distances IR [mm]


Type Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E IR 400 400 400 700 2300

Min. distances EZ 300 [mm]


Type Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E EZ300 115 250 250 700 1800
B A C D E

40

Radiant heaters - Industry and Outdoors

Infrared heater IRCF


IRCF is especially designed for spot heating of premises with large air volumes, such as churches, aircraft hangars and marquees. With 3-5m its high efficiency and compact size it is perfect for many difficult applications. Discreet and compact design. Equipped with one to three halogen lamps and with glossy finished reflectors. Easy mounting with mounting bracket on the wall or ceiling. The heater can be angled Protection grille available as an accessory. Max. element temperature: 2200 C. Colour: RAL 9006 CE compliant.

Infrared heater IH
IH is an efficient heater and a perfect choice for exposed outdoor applications where design is important. There are two versions of 1,8 - 3,5 m IH, which allows a number of permutations. IHW gives a comfortable heat in the occupied area from close range and also wider heat distribution. IHF has more direct heat distribution and is designed to be installed higher up. IH is easy to position thanks to its compact design. IH consists of a halogen lamp with a very high intensity and a brightly-polished reflector for optimum heat distribution. Supplied with adjustable mounting bracket for wall mounting. Max. element temperature: 2200 C. Colour: RAL9006 CE compliant. Infrared heater IHW with wide heat distribution (IPX4)
Heat output [W] 1500 3000 4500 HxWxD [mm] 490x230x140 490x375x140 490x515x140 Weight [kg] 2,0 2,5 3,0 Type IHW10 IHW15 IHW20 Voltage [V] 230V~ 230V~ 230V~ Heat output [W] 1000 1500 2000 LxH*xD [mm] 500x77x169 500x77x169 500x77x169

Infrared heater IRCF (IP20)


Type IRCF1500 IRCF3000 IRCF4500

3
Weight [kg] 1,9 1,9 1,9

Voltage [V] 230V~ 230V~ 230V~/400V3~

Accessories - IRCF
Type S123 CBT T10 TK10 KRT1900 IRCFL15 IRCG1 Description

Infrared heater IHF with directed heat distribution (IPX4)


Voltage [V] IHF10 230V~ IHF15 230V~ IHF20 230V~ *) without brackets Type Heat output [W] 1000 1500 2000 LxH*xD [mm] 500x77x169 500x77x169 500x77x169

Manual switch for 1-2-3 steps, IP42 Electronic timer, IP44 Electronic thermostat with concealed knob Electronic thermostat with visible knob Capillary room thermostat, IP55 Extra lamp Protection grille for IRCF1500. IRCF3000 require 2 pcs, IRCF4500 require 3 pcs. For controls, see pages 43 and 56-57.

Weight [kg] 1,9 1,9 1,9

Accessories - IH
Type Description

CBT Electronic timer, IP44 IHL1000 Halogen lamp 1000W IHL1500 Halogen lamp 1500W IHL2000 Halogen lamp 2000W For controls, see pages 43 and 56-57.

Min. distances IRCF [mm]

Min. distances IH [mm]


Type IH A B C 200 1000 1800 Ceiling Flammable material Floor

B
B C

Type Ceiling Wall Floor A B C

IRCF 500 50 2300

Type Ceiling Wall Floor A B C

IRCF 180 500 2300

B C

41

Radi an t h e a t e r s

Radiant heaters - Outdoors

Infrared heater CIR


CIR provide comfort all year around on terraces, balconies and open-air restaurants. CIR can also be used for spot heating in workshops and warehouses. Requires no 2-3 m protection against bad weather and has fiveyear corrosion warranty. CIR is discreet with its slim design and silent operation and needs little space to fit in. Reflectors of high-gloss polished aluminium with maximum resistance against corrosion. Grey terminal boxes of heat and weather resistant polycarbonate. Adjustable mounting brackets for easy mounting on the wall or ceiling. Max. element temperature: 750 C. Colour: white, RAL 9002. Approved by SEMKO and CE compliant.

Infrared heater ELIR


ELIR gives an intense heat suitable for all outdoor applications and tough industrial premises. While ELIR is light, stable and 2-3 m portable it is also well suited for temporary heating on building sites etc. With its concentrated heat it is a good complement to dehumidifiers for drying in areas damaged by water. High protection class (IP65) offers a wide range of installation possibilities. Thorough design in a compact format. Simple, robust and light (1 kg). All parts are anti-corrosive. Casing/reflectors of high-gloss polished aluminium with maximum resistance against corrosion. Grey terminal boxes of heat and weather resistant plastic. ELIR is mounted on the wall with the accompanying mounting bracket or suspended from the ceiling. It can also be mounted on a stand for portable use. Suspension details and stand are extra. Max. lamp temperature: 2200 C. Colour: RAL 7035. CE compliant.

Infrared heater CIR without built-in switch (IP24)


Type CIR10521 CIR11021 CIR11031 CIR11521 CIR11531 CIR12021 CIR12031 Voltage [V] 230V~ 230V~ 400V2~ 230V~ 400V2~ 230V~ 400V2~ Heat output [W] 500 1000 1000 1500 1500 2000 2000

3
Weight [kg] 1,5 2,2 2,2 3,0 3,0 3,7 3,7

LxHxD [mm] 710x44x94 1250x44x94 1250x44x94 1755x44x94 1755x44x94 2180x44x94 2180x44x94

Infrared heater ELIR (IP65)


Type ELIR12 Voltage [V] 230V~

3
Heat output [W] 1200 LxHxD [mm] 712x112x83 Weight [kg] 1,0

Infrared heater CIR with built-in switch (IP24)


Type CIR20521 CIR21021 CIR21031 CIR21531 CIR22031 Voltage [V] 230V~ 230V~ 400V2~ 400V2~ 400V2~ Heat output [W] 500 1000 1000 1500 2000

3
Weight [kg] 1,5 2,2 2,2 3,0 3,7

Accessories - ELIR
Type Description

LxHxD [cm] 710x44x94 1250x44x94 1250x44x94 1755x44x94 2180x44x94

Accessories - CIR
Type Description

ELIRC Chain for ceiling mounting ELIRS Floor stand (tripod) with bracket for ELIR included ELIRB Universal bracket when using any floor stand (i.e. tripod) IREL12 Extra lamp CBT Electronic timer, IP44 For controls, see pages 43 and 56-57.

CIRT Stepless output control with timer, IP44 CBT Electronic timer, IP44 For controls, see pages 43 and 56-57.

Min. distances ELIR [mm]

Min. distances CIR [mm]

150

Typ Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E

ELIR 400 600 600 1000 1800

300 700 1800

150

42

Radiant heaters - Controls

ERP

CIRT

S123

ERP electric heating control ,


ERP is a modern, variable control that precisely adapts energy use to the current demand. Intended for single-phase or 2-phase electrical heaters. The control is connected in series between the mains and an electrical heater. The current is electronically switched by a triac without any moving parts. Therefore, the ERP is silent and maintenance free. ERP makes the temperature of the heaters even, for maximum comfort. The current is switched at zero phase angle, to eliminate network disturbance. ERP has a built-in temperature sensor, but external sensors (extra) can be connected and be mounted in a room or incoming air channel. For larger power outputs a slave unit (ERPS) can be connected. Each ERPS can handle the same power as ERP . Functions ERP: Comfort temperature, economy saving via external time switch. Ambient temperature: 030 C. Economy saving: 010 C. Voltage: 230V~/400V2~ Load: 3500/6400 W Dim: 153x94x43 mm Colour: white. IP20. CE compliant. Accessories ERP
Type ERPRG ERPGG ERPS Description Room sensor ERP Floor/duct sensor ERP Slave unit ERP

CIRT, stepless output control


Stepless output control with timer, primarily intended for infrared heaters and other radiant heaters. Especially suited for spot and zone heating. The heat contribution is regulated for best comfort (25-100 %). The built-in timer can be set for 0,5 to 4 or 4 to 24 hours. IP44. Voltage: 230 V~/400 V2~ Load: 3500/6000 W Dim: 155x87x43 mm CE compliant.

S123, manual switch for 1-2-3 steps


Controls the output in three steps 0-1/3-2/3-3/3. Used with EZ300, IR or IRCF it is possible to manually connect , the heaters elements 1 + 1 + 1. IP42. Dim: 72x64x46 mm CE compliant.

43

Radi an t h e a t e r s

Fan heaters
For decades Frico has been the world leader in fan heater design. Today we have a complete range of high quality equipment modelled on the demanding climate of Scandinavia. Fricos worldwide distribution network encounters many different environmental conditions, such as storage rooms, pump rooms, building sites, mines, sports centres, shops, drying rooms, stables, boats, etc. We are proud of the worldwide acclaim we have gained through our line of fan heaters. They are known as reliable and long-lasting products. The heaters are also robust and will withstand rough treatment in aggressive environments, at the same time having the lowest sound level on the market.

Exceptionally quiet One of the most important tasks in our product development, is the construction of low noise fan heaters. At our plant in Skinnskatteberg, Sweden, you will find one of the most sophisticated air and sound laboratories in Europe, staffed by highly skilled technicians making it possible to manufacture products of the finest quality. Lots of power, small investment Compared to other heating systems, the investment cost for fan heaters is low. Frico fan heaters give you lots of power for the money. Compact and robust Frico fan heaters are compact and light. Therefore they are easy to carry or can easily be mounted on the wall. The heaters are also very robust and withstand heavy handling in aggressive environments. Electricity or water? Frico fan heaters are available for electrical or water heating - you have the choice! Heating and ventilation A great advantage of fan heaters is the option of combining heating and ventilation. Mixing cabinets for stationary fan heaters create economic heating and ventilation, by mixing the return air with fresh air.

44

Fan heaters - portable

Fan heater K21


K21 is a robust and compact fan heater for portable use. Suitable for heating of a variety of small areas such as garages, caravans, cottages, offices and terraces. If K21 is used outdoors, it should be protected under a roof. K21 has a self-limiting ceramic PTC element and low airflow. This gives an intense hot air (the air is heated approximately 65 C when it passes through K21). K21 is equipped with a 2 metre cable with an earthed plug. Thermostat with setting range 5 40 C. Colour: white, RAL 9016. Approved by SEMKO and CE compliant.

Fan heater Tiger 15 kW


Tiger fans with 15 kW output are designed for heating and drying, when there is demand for high output. Suitable application areas are for example warehouses, industry and workshops. Can be mounted on the wall and has resetable overheat protection. Delivered with 1,8 m cable with CEE plug. Thermostat with setting range 5 35 C. Colour: red, RAL 3020. CE compliant.

Fan heater Tiger 15 kW (IP44)


Type Voltage [V] 400V3~

3
Airflow [m/h] 1120 HxWxD [mm] 510x410x530 Weight [kg] 15,9

Fan heater K21 (IP21)


Type K21 Voltage [V] 230V~

3
Airflow [m/h] 90 HxWxD [mm] 220x160x200 Weight [kg] 2,5

P153

Output steps [kW] 0/7,5/15

Output steps [kW] 0/1/2

Fan heater Tiger 29 kW


Tiger is a range of fan heaters for portable use. The compact and robust design makes them suitable for use in workshops, garages and shops. Tiger can easily be hung on the wall. With the mode selector, the thermostat can be set to control just the heat or both heat and fan. The latter means that the fan is running only until the set temperature is reached. Thermostat with setting range 5 35 C. Tiger 2 kW and 3 kW have plugs for connection to earthed wall sockets. (3 kW requires 16 A fuse.) The 400 V3N~ Tigers have a CEE plug mounted on the cable, and on the back of each, there is a 230 V~ socket for hand lamps, drills, battery chargers, etc. Colour: red, RAL 3020. CE compliant.

Fan heater Tiger 20 and 30 kW


Tiger fans with 20 kW and 30 kW output are primarily used for heating and drying, when there is demand for high output. These heaters are very reliable and highly resistant to rough handling and vibrations. Suitable areas of use are for example warehouses, industry, mines and workshops. Tiger 20 kW and 30 kW have a switch for full/half airflow. Delivered with cable without plug. Thermostat with setting range 5 35 C. Colour: red, RAL 3020. CE compliant.

Fan heater Tiger 20 and 30 kW (IP44)


Voltage Output steps [V] [kW] P203 400V3~ 0/10/20 P303 400V3~ 0/10/20/30 P3053* 440V3~ 0/7,5/15/23/ 500V3~ 0/10/20/30 *) Convertible 440/500 V3~ Type

3
HxWxD [mm] 590x630x600 590x630x600 590x630x600 Weight [kg] 25,5 29,5 30,0

Fan heater Tiger 29 kW (IP44)


Type

3
Airflow [m/h] 280 280 480 280 480 720 HxWxD [mm] 450x290x390 450x290x390 450x290x390 450x290x390 450x290x390 530x350x480 Weight [kg] 5,7 6,0 6,4 6,3 6,7 10,2

Voltage Output steps [V] [kW] P21 230V~ 0/2 P31 230V~ 0/2/3 P51 230V~ 0/3,3/5 P33 400V3N~* 0/1,5/3 P53 400V3N~* 0/2,5/5 P93 400V3N~* 0/4,5/9 *) Also available without neutral

Airflow [m/h] 1900/2600 1900/2600 1900/2600

Accessories - Tiger
Type LT22406 Description Wall bracket

45

Fan heater s

Fan heaters - portable / wall mounted

Fan heater P3110


P3110 is is a robust and compact fan heater for portable use. The housing is made from galvanized, red painted sheet metal. The heating elements are stainless and encapsulated. The thermostat measures the temperature of the input air, which gives high accuracy. Can be used in damp or wet areas and on building sites. P3110 has a reset button for the over-heating protection on the top. Can also be wall mounted. P3110 is equipped with a 2 metre cable with an earthed plug. Thermostat with setting range 0 35 C. Colour: red. Approved by SEMKO and CE compliant. Fan heater P3110 (IPX4)
Type P3110-UK Voltage [V] 110V~

Fan heater Cat


Cat is a range of compact and robust fan heaters for wall mounting. The heaters are well suited for the heating of buildings such as smaller warehouses, garages, workshops and shops. Output selector with two steps. Thermostat range 535 C. With the mode selector, the thermostat can be set to control both heat and fan or just the heat. Cat can also be controlled via external output selector, thermostat and timer if so desired. With a mixing cabinet, heating can be combined with ventilation by mixing return air with fresh air. A mixing cabinet is available as an accessory for Cat 3 and 5 kW (includes an outer wall grille, a masonry frame and a control lever). All Cat heaters are equipped with mounting brackets with a preset downward angle of 10. Colour: white, RAL 9016. CE compliant. Fan heater Cat (IP44)
Type C3* Voltage

3
Output steps [kW] 0/1.5/3 Airflow [m/h] 290 HxWxD [mm] 320x275x320

3
Airflow Sound HxWxD level [m/h] [dB(A)] [mm] 280 41 255x335x276 40 44 255x335x276 315x405x335 Weight [kg) 6,3 6,7 10,2

[V] 230V~ 400V3N~ C5 400V3N~ 0/2,5/5 480 C9 400V3N~ 0/4,5/9 720 *) Convertible 230 V/400 V3N~

Output steps [kW] 0/1,5/3

Control kits Cat


Built-in control:

Door heater PA1006


PA1006 is a compact door heater which heats the incoming air and gives increased comfort on the inside. When wall mounted, the unit can act as a stationary fan heater. The bracket included in delivery makes it possible to angle the unit 30 out from the wall, which gives an even heat distribution in the premises. The door heater has a clean, straight forward design. As the air inlet is placed on top of the unit the front of the unit is kept free of dirt and dust. Colour: white, RAL 9016. CE compliant. Door heater PA1006E03 (IP20)
Type

The built-in thermostat controls fan speed and heat, or heat only. The choice is made with the mode selector. The output can be controlled via the built-in output selector (0-1/2-1/1). External regulation: T10 or KRT1900, room thermostats EV300, output selector CBT, electronic timer or KUR, digital time switch Accessories - Cat
Type Description

Voltage Output Airflow Sound HxWxD Weight steps level [V] [kW] [m/h] [dB(A)] [mm] [kg] PA1006E03 230V~ 0/1.5/3 230 44 153x164x650 5,3

T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 TKS16 Room thermostat with knob, 1-pole switch, IP30 KRT1900 Room thermostat, IP55 EV300 Output selector, IP44 CBT Electronic timer, IP44 KUR Digital time switch, IP44 CMB35 Mixing cabinet for C3 and C5 TP3/5 Cover panel for switches for C3 and C5 TP9 Cover panel for switches for C9 For controls, see pages 56-57.

CMB35 with Cat

EV300, output selector Output steps: 01/21/1. Dim 100x80x90 mm. IP44.

46

Fan heaters - demanding environments

Fan heater Elektra


Elektra is a fan heater range for demanding conditions. It is compact and robust. Elektra is primarily intended for wall mounting, but the brackets can be angled for portable use. Elektra is available in four versions: Elektra C for corrosive and damp environments, such as car wash areas. IP65. Elektra F for rooms with increased risk of fire, such as carpenters workshops and farms. IP65. Elektra V i.e. for ships and offshore platforms. Approved by Det Norske Veritas. IP44. Elektra H for rooms with high temperatures, up to +70 oC. IP44. Thermostat with setting range 035 C (ELC, ELF and ELV) and 070 C (ELH). Colour: casing of acid-proof stainless steel panels (ELC) and stainless steel panels (ELF , ELV and H). Grille and bracket RAL 3020 (red). Approved by SEMKO and CE compliant. Elektra V is approved by Det Norske Veritas.
Elektra F for rooms with increased risk of fire, such as carpenters workshops and farms. IP65. Elektra C for corrosive and damp environments, such as car wash areas. IP65.

Fan heater Elektra (C-F IP65/V-H IP44)


Type ELC331 ELC633 ELC933 ELC1533 ELF331 ELF633 ELF933 ELV331 ELV3333 ELV3344 ELV5333 ELV6344 ELH633 ELH933 Connection voltage [V] 230V~ 400V3~ 400V3~ 400V3~ 230V~ 400V3~ 400V3~ 230V~ 400V3~ 400/440V3~ 400V3~ 400/440V3~ 400V3N~ 400V3N~ Output steps [kW] 0/1,5/3 0/3/6 0/4,5/9 0/7,5/15 0/1,5/3 0/3/6 0/4,5/9 0/2/3 0/1,5/3 0/1,8/3,6 0/2,5/5 0/3/6 0/3/6 0/4,5/9

3
Weight [kg] 13 20 20 20 13 13 20 13 13 13 13 13 20 20 Elektra V i.e. for ships and offshore platforms. Approved by Det Norske Veritas. IP44. [mm] 375x300x340 445x375x430 445x375x430 445x375x430 375x300x340 445x375x430 445x375x430 375x300x340 375x300x340 375x300x340 375x300x340 445x375x430 445x375x430 445x375x430

Airflow HxWxD [m/h] 400 1000 1000 1300 400 700 1000 400 400 400 700 700 1000 1000

Accessories - Elektra
Type ELSRT ELSRT4 ELS ELRT KRT1900 Description Control box with thermostat for ELC and ELV, start/stop, 175x150x100 mm Control box with thermostat for ELC and ELV, start/stop, for 4 units, 255x360x110 mm Control box for ELF , start/stop, 105x70x80 mm Room thermostat for ELH, 175x150x100 mm Room thermostat, IP55

Elektra H for rooms with high temperatures, up to +70 oC. IP44.

ELSRT

ELSRT4

ELS

ELRT

47

Fan heater s

Fan heaters - wall mounted

Fan heater Panther 6 15 kW


Panther models are very quiet and efficient fan heaters for wall mounting. They are suitable for the heating, drying and ventilation of for example workshops, sport centres, shops, gymnasiums and drying rooms. The flexible mounting bracket makes it possible to direct the air stream. Panther is delivered with a built-in thermostat range 5 35 C. Output and fan speed can be set on the control panel, which is extra. Master/slave function. Colour: white, RAL 9016. CE compliant.

Fan heater Panther 20 and 30 kW


Panther models are very quiet and efficient fan heaters for wall mounting. They are suitable for the heating, drying and ventilation of industrial areas. Flexible mounting bracket makes it possible to direct the air stream. Output and fan speed can be set on the control box, which is extra. The temperature is controlled with a Frico thermostat. Over run thermostat to protect elements. Colour: white, RAL 9016. CE compliant.

Fan heater Panther 6-15 kW (IP44)


Output steps [V] [kW] SE06 400V3N~ 0/3/6 SE09 400V3N~ 0/4,5/9 SE12 400V3N~ 0/6/12 SE15 400V3N~ 0/7,5/15 SE135 440V3~ 0/5/10 500V3~* 0/7/13,5 *) Convertible 440/500 V3~ Type Voltage Airflow [m/h] 900/1300 900/1300 900/1300 900/1300 900/1300 900/1300

3
Sound level [db(A)] 39/47 39/47 39/47 39/47 39/47 HxWxD [mm] 520x450x510 520x450x510 520x450x510 520x450x510 520x450x510 520x450x510 Weight [kg] 21 22 22 22 23

Fan heater Panther 20 and 30 kW (IP44)


Output steps [V] [kW] SE20 400V3N~ 0/10/20 SE30 400V3N~ 0/10/20/30 SE305 440V3~ 0/7,5/15/23 500V3~* 0/10/20/30 *) Convertible 440/500 V3~ Type Voltage Airflow

3
HxWxD [mm] 576x478x545 576x478x545 576x478x545 576x478x545 Weight [kg] 27 31 32

Sound level [m/h] [db(A)] 1900/2600 52/60 1900/2600 52/60 1900/2600 52/60 1900/2600

Control kits Panther 6-15 kW


Fan speed and thermostat control: PP15, control box, controls the output in two steps and the airflow in three steps. Automatic temperature control: PTA, automatic temperature control Control of mixing cabinet: PHR01, control lever, manual damper control or PSA01, automatic damper and temperature control PSM01, damper motor, is used in combination with PSA01 when several mixing cabinets should be controlled

Control kits Panther 20 -30 kW


Fan speed and thermostat control: KRT2800 or RTI2, 2-step room thermostats PP20, control box, controls the output in two steps and the airflow in two steps (SE20) PP30, control box, controls the output in three steps and the airflow in three steps (SE30, SE305). Automatic temperature control: PTA, automatic temperature control Control of mixing cabinet: PHR01, control lever, manual damper control or PSA01, automatic damper and temperature control PSM01, damper motor, is used in combination with PSA01 when several mixing cabinets should be controlled

48

Fan heaters - wall mounted

PP15/20/30

PTA01

PBS01/02

PSA01

Product specific accessories - Panther 6 15 kW and Panther 20 and 30 kW


PP15/20/30, control box
Desired output and fan speed can be set on the control box. Up to six units can be regulated from one control box. IP44. Accessories Panther 6-12, 20 and 30 kW
Type Description

PTA01, automatic temperature control


The PTA01 can be used to lower the heat when necessary, for example over nights and weekends. The control consists of an electronic time switch (24-hour/week setting) and an electronic thermostat with an external sensor. The time switch alternates between day and night mode. IP55.

PBS01/02, mixing cabinet


Saves energy by mixing return air and fresh air in choosen proportions. Supplied with outer wall grille and masonry frame. Damper controls are extra.

PHR01, control lever for mixing cabinet


A control lever is used to control the mixing cabinet manually. The rod (not included) for the lever should have a diameter of 8 mm.

PSM01, damper motor


The damper motor is used in combination with PSA01 when several mixing cabinets should be controlled (one damper motor is included in PSA01). IP54.

PLR15/30, air director


Directs the air stream vertically or horizontally. PLR is snapped on the front of the heater. Torsional (turning) angle 0 35.

PSA01, automatic damper and temp. regulator


Lowers the temperature and reduces the air intake when the demand is lower. Consists of timer and thermostat with sensor, potentiometer and damper motor. If an exhaust fan is used, it can also be controlled with PSA01. IP55.

PTRP drying room kit ,


Consists of exhaust air fan, thermostat and timer. The exhaust air fan works alternately with for example a fan heater for shortest possible drying time and minimal energy consumption. A complete kit includes Panther fan heater with output 6-12 kW.

PFF15/30, exhaust air fan


Can be used for example in combination with the fan heater/mixing cabinet to obtain good ventilation. Air flow approximately 1400 m3/h or 2600 m3/h.

49

Fan heater s

PP15 Control box SE06 - SE15, IP44 PP20 Control box SE20, IP44 PP30 Control box SE30 and SE305, IP44 PTA01 Automatic temperature control, IP55 PBS01 Mixing cabinet SE06 SE15 PBS02 Mixing cabinet SE20, SE30 and SE305 PHR01 Control lever for mixing cabinet PSM01 Damper motor, IP54 PLR15 Air director SE06 SE15 PLR30 Air director SE20, SE30 and SE305 PSA01 Automatic damper and temp. control, IP55 PTRP Drying room kit without fan heater PFF15 Exhaust air fan SE06 SE15, IP54 PFF30 Exhaust air fan SE20, SE30 and SE305, IP54 KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 CBT Electronic timer, IP44 KUR Digital time switch, IP44 For controls, see pages 56-57.

Fan heaters - wall mounted, water heated

Fan heater SW
Fan heater SW is suitable for heating of buildings such as industrial premises, work shops and warehouses. Thanks to Frico technology which optimises the air flow through the battery, extremely low sound levels are obtained. The sound level can be as low as 35 dB(A). The basic unit consists of an integrated motor with an axial fan and a water-supplied heating coil and a corrosion proof casing of hot zinc-plated powder lacquered steel panels. Delivered with air director. The heater can be mounted on the wall or on the ceiling, and water connection can be done either on the right or left side. The airflow can be controlled in three steps. A thermostat is needed to regulate the water valve, see section on Thermostats. Mounting brackets are extra. Colour: white, RAL9016. CE compliant. Fan heater SW 1222 (IP44)
Type

Voltage Output Airflow Sound HxWxD Weight steps* level [V] [kW] [m/s] [dB(A)] [mm] [kg] SW12 230V~ 12-17 0,30/0,51 35/49 580x525x405 25 SW22 230V~ 23-30 0,50/0,90 41/52 725x680x410 30 *) Applicable at water temperature 80/60 C, air temperature, in +15 C

Control kits SW12 and SW22


Control by thermostat only: KRT(V), T(K)10 or RTI2, room thermostat SWR20/25, valve set, or TVV20/25, valve + SD20, actuator 3-step control of airflow only: SWR2, 3-step fan speed control Thermostat and 3-step control:

Fan heater SW 02 (IP44)


Type

Voltage Output Airflow Sound HxWxD Weight steps* level [V] [kW] [m/s] [dB(A)] [mm] [kg] SW02 230V~ 8-10 0,20/0,31 34-45 520x450x510 15 *) Applicable at water temperature 80/60 C, air temperature, in +15 C

SWR2, 3-step fan speed control KRT(V), T(K)10 or RTI2, room thermostat SWR20/25, valve set, or TVV20/25, valve + SD20, actuator Automatic temperature and airflow control: SWR1, airflow/temperature control (thermostat included) SWR20/25, valve set, or TVV20/25, valve + SD20, actuator

Accessories - Fan heater SW 02


Type Description

T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 KRT2800 2-step room thermostat, IP55 KUR Digital time switch, IP44 CB30N Control box RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 SWFT02 Basic filter SW22 SWR20 Valve set connection DN20 SWR25 Valve set connection DN25 TVV20 2-way control valve DN20 TVV25 2-way control valve DN25 SD20 Actuator For controls, see pages 56-58.

Fan heater SW 3233 (IP54)


Type

Voltage Output Airflow Sound HxWxD Weight steps* level [V] [kW] [m/s] [dB(A)] [mm] [kg] SW32 230V~ 28-50 0,67/1,72 39/60 855x820x530 40 SW33 230V~ 35-65 0,63/1,59 38/60 855x820x530 45 *) Applicable at water temperature 80/60 C, air temperature, in +15 C

Control kits SW32 and SW33


Control by thermostat only: KRT(V), T(K)10 or RTI2, room thermostat SWR20/25, valve set, or TVV20/25, valve + SD20, actuator 5-step control of airflow only: RE3, 5-step fan speed control 3A, or RE7, 5-step fan speed control 7A Thermostat and 5-step control: RE3, 5-step fan speed control 3A, or RE7, 5-step fan speed control 7A KRT(V), T(K)10 or RTI2, room thermostat SWR20/25, valve set, or TVV20/25, valve + SD20, actuator

CB30N, control box Controls the airflow in 3 steps. Max input 10 A. IP44.

50

Fan heaters - wall mounted, water heated


SWR1

SWR

RTI2

SWR2

RE3/RE7

2 3 6 4 1 8 5 7

SWR1, automatic temperature control


Only for SW12 and SW22. Controls the room temperature through automatic adaptation of the fan speed. When the heat demand is low the fan speed is low and when the heat demand increases the fan speed is increased accordingly. Manual control is possible. Consists of a thermostat RTI2 and a control box SWR Controls up to six SW in parallel.

SWR2, 3-step fan speed control


Only for SW12 and SW22. Controls up to six SW in parallel. IP44.

RE3, 5-step fan speed control


Only for SW32 and SW33. Controls the fan speed in 5 steps, max. 3 A. Controls up to one SW. IP54.

RE7, 5-step fan speed control


Only for SW32 and SW33. Controls the fan speed in 5 steps, max. 7 A. Controls up to two SW. IP54.

1) Fan heater SW 2) Mounting brackets SWK 3) Basic filter SWFT 4) Filter section SWF 5) Return air inlet SWD 6) Mixing cabinet SWBS 7) Outer wall grille SWY 8) Extra air director SWLR Figs. 4, 5, 6 and 8 are corrosion proof, hot zinc-plated. All steel panels are white powder coated.

SWK, mounting brackets


Fig. 2. When not using the filter section or mixing cabinet the main unit is suspended from the wall or ceiling using brackets SWK. Brackets are extra and supplied as a pair.

Accessories - Fan heater SW 12 - 33


Type Description

SWFT, basic filter


Fig. 3. Used as an alternative to the filter section. Provides the heating coil with basic protection. The filter is easily fitted into the SW unit and can be cleaned from either the top or bottom of the SW unit. The SW unit has a re-usable filter.

SWF, filter section


Fig. 4. Filters the outdoor air or/and return air from particles that might reduce the performance and reliability of SW. The disposable deep-pleated bagfilter is a cassette of synthetic material. Filterclass G85 (EU3). The filter section is equipped with filter on delivery. Note! If the filter section is not used in combination with the mixing cabinet, a return air inlet (SWD) is required.

SWEF, extra filter cassette


Replacement filter for SWF .

SWD, return air inlet


Fig. 5. Allows air inlet when filter section is used without mixing cabinet SWBS. Return air inlet is not required when the mixing cabinet is used.

SWBS, mixing cabinet


Fig. 6. The mixing cabinet is used to combine ventilation with heating by mixing outdoor air with return air. The mixture ratio is controlled and infinitely variable with a damper, either manually or with a damper motor.

SWY, outer wall grille


Fig. 7. For intake of fresh air into the mixing cabinet. Grille of hot zinc-plated steel panels.

SWLR, extra air director


Fig. 8. To direct the air stream sideways. On delivery, SW is equipped with an air director for vertical direction of the air stream. Individually adjustable louvres in anodized aluminium. The extra air director is mounted to SW by hooking it onto the existing air director.

SWK1 Mounting brackets SW12 SWK2 Mounting brackets SW22 SWK3 Mounting brackets SW32/33 SWLR1 Extra air director SW12 SWLR2 Extra air director SW22 SWLR3 Extra air director SW32/33 SWF1 Filter section SW12 SWF2 Filter section SW22 SWF3 Filter section SW32/33 SWD1 Return air inlet (SWF1) SW12 SWD2 Return air inlet (SWF1) SW22 SWD3 Return air inlet (SWF1) SW32/33 SWEF1 Extra filter cassette SW12 SWEF2 Extra filter cassette SW22 SWEF3 Extra filter cassette SW32/33 SWFT1 Basic filter SW12 SWFT2 Basic filter SW22 SWFT3 Basic filter SW32/33 SWBS1 Mixing cabinet SW12 SWBS2 Mixing cabinet SW22 SWBS3 Mixing cabinet SW32/33 SWSM01 Damper motor SWY1 Outer wall grille SW12 SWY2 Outer wall grille SW22 SWY3 Outer wall grille SW32/33 SWMSK Motor protection 0.4 10 A SWR1 Automatic temperature control SW12/22, IP44 SWR2 3-step fan speed control SW12/22, IP44 RE3 5-step fan speed control SW32/33, IP54 RE7 5-step fan speed control SW32/33, IP54 T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 KUR Digital time switch, IP44 SWR20 Valve set connection DN20 SWR25 Valve set connection DN25 TVV20 2-way control valve DN20 TVV25 2-way control valve DN25 SD20 Actuator For controls, see pages 56-58.

51

Fan heater s

Ceiling fans

Ceiling fan ICF


Ceiling fans are used primarily to equalize the temperature in rooms with high ceilings, such as industrial and warehouse buildings, gymnasiums, and shops. Several controls as well as downrods and blades of different sizes are available, making it possible to adapt ceiling fan ICF to almost all premises. Ceiling fan ICF pushes the hot air from the ceiling and thus lowers the temperature there, the heat losses through the roof and walls are reduced and in many cases, heating costs can be reduced by up to 30%. Industrial ceiling fan ICF has a functional design and white colour which blends well in most premises. The low sound level makes it even more discreet. Can operate clockwise and counter-clockwise. Canopie with vibration absorption. The fan speed of ceiling fans should be regulated to obtain optimal heat equalization and prevent draught, see accessories. Protection class ICF20: normal design (IPX0) Protection class ICF55: splash-proof design (IPX5) Colour: white, NCS S 0505-R90B. Approved by IMQ and CE compliant.

Ceiling fan ICF (ICF20:IPX0 / ICF55:IPX5)


Type ICF20 ICF55 Voltage [V] 230V~ 230V~ Output [kW] 70 70 Airflow [m/h] 13500 13500

3
HxWxD [mm] 545x1422 545x1422 Weight [kg] 6,2 6,2

Accessories - ICF
Type CAR15 CFR1R PE1 PE2,5 RE5 CFAP200 CFAP750 CFB900 CFB1200 Description Automatic fan speed control 5-step fan speed control for 1 fan Stepless fan speed control for 2 fans Stepless fan speed control for 6 fans 5-step fan speed control for 12 fans Short downrod, total height 395 mm Long downrod, total height 945 mm Fan blades 914 mm (3 pcs) Fan blades 1218 mm (3 pcs)

Product specific accessories, ICF


CAR15, automatic fan speed control Control a maximum of 15 fans. Automatic fan speed control, through external sensor, in accordance with variations in the temperature between the ceiling and the floor. Built-in switch for reversed rotation. IP33. CFR1R, 5-step fan speed control Built-in switch for reversed rotation. Controls a maximum of 1 fan. IPX0. RE5, 5-step fan speed control Controls a maximum of 12 fans. IP54. PE, stepless fan speed control Single-phase manual thyristor for stepless speed adjustment of the fan and on/off control. PE1 controls a maximum of 2 fans. PE2,5 controls a maximum of 6 fans. For external mounting (IP54) or recessed mounting (IP44).
a

CAR15

CFR1R

a/2

RE5

PE1/PE2,5
a/2

Ceiling height (m) Distance between fans a (m)

Recommended distance between fans 4 6 8 10 12 5 7 8 9 10

52

Convectors
The rotary movement of air that forms in a room where the air is affected by a heat source is called convection. The air gets warm and rises then cools and returns to be heated again. Heat disperses in the room while the upward directed warm air stream is utilised to counteract cold draughts from windows for example. The ribbed pipe radiator is our oldest product that is still produced. The design is essentially the same as when it was first developed in the 1930s. The robust and durable construction is still very popular and has even found a new market in modern houses with large windows where ribbed pipe radiators are used for discrete heating and protection against cold draught. Our aim is for all our products to become classic. They should have a design that lasts, high quality and the best performance.

Ribbed pipe radiator


Frico ribbed pipe radiators are very robust and durable.The ribbed-pipe flanges give a large heat-emitting surface and make the radiator compact. Equipped with protection grille for higher safety. Areas of use are for example wardrobes, dressing-rooms and small store rooms. Type 126 is equipped with an output selector 01/32/31. Resetable overheat protection covers the whole length of the unit. The radiators are to be mounted horizontally on the wall with the overheat protection on the upper side of the unit. Colour: dark green, RAL 6005. CE compliant. 125-32B, 125-42B and type 126 are approved by Det norske Veritas. Type 127 is sand filled and recommended for use in rooms where there is risk of fire and for use in agricultural buildings. Ribbed pipe radiator (IP44)
Type 125-12B 125-22B 125-32B 125-42B 126-32B 126-42B 126-52B 127-22B 127-42B Voltage [V] 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~

Frost guard
Frost guards are small, compact and give off a lot of heat despite their small size. They are appropriate for heating or frost protection in many different locations such as food cellars, pump houses, junction boxes, storage areas etc. Wall fixtures are included. FML must be mounted in a horizontal postition with the knob on the right hand side. FMS is mounted in a vertical position. Equipped with 1 metre cable, earthed plug and thermostat. The thermostat can be variably controlled from the frost guard position of +5 C up to +35 C. Stainless steel heating element. Built-in overheat protection. Colour: white front. FMLR200 is in stainless steel. CE compliant.

3
LxWxD [mm] 370x180x185 530x180x185 730x180x185 880x180x185 730x180x185 880x180x185 1185x180x185 980x180x185 1925x180x185 Weight [kg] 2,4 3,3 4,5 5,5 4,7 5,7 7,5 10,9 33,3

Frostguard FMS, FML, FMLR (IP31)


Type FMS200 FMLR200 FML200 FML300 FML450 Voltage [V] 230V~ 230V~ 230V~ 230V~ 230V~

3
LxWxD [mm] 90x298x68 298x90x68 298x90x68 398x90x68 498x90x68 Weight [kg] 0,7 0,7 0,7 0,9 1,1

Heat output [W] 200 375 575 775 575 775 1150 500 800

Heat output [W] 200 200 200 300 450

min 300

250
180 125

50 60

185

min 200

53

Co nvecto r s

Convectors

Fan convector PF
The fan convector is designed to operate using less energy than ordinary radiators. The airflow equalises the temperature difference between floor and ceiling, which gives a higher efficiency and lower energy consumption compared to radiators without fan. The lower surface temperature allows painting of the front plate by the user if required. The standard version of PF is painted white. The circulating airflow created by the fan convector makes it suitable for installations where rapid heating is desired. The fan is very quiet with a sound level below 30 dB(A). Approved by SEMKO and CE compliant.

Fan convector PFW, water heated


Effective heating can be maintained with considerably lower water temperature as the fan distributes the heat from the radiator quickly and efficiently. The product is adapted to todays low temperature heating systems and replaces conventional radiators. The unit is equipped with a filter.

Fan convector PFW, water heated (IP23)


Voltage Heat output* [V] [W] PFW10 230V~ 0-1000 PFW20 230V~ 0-2000 *) Depending on the water temperature Type

2
LxWxD [mm] 598x330x100 1058x330x100 Weight [kg] 7,3 12,8

Accessories - PFW
Type PFFAL Description Front, brushed aluminium

Fan convector PFE/PFD, electrically heated


The PFE/PFD convectors have an electronic thermostat with night set-back facility. When installing several radiators, it is possible to use one as a master. All electrical radiators are equipped with overheat protection. Models up to 800 W have a lower surface temperature than most heating appliances (60 C nominal).

Fan convector PFE/PFD, electrically heated (IP23)


Type PFE5 PFE8 PFE10 PFE12 PFD5 PFD8 PFD10 PFD12 Voltage [V] 230V~ 230V~ 230V~ 230V~ 400V2~ 400V2~ 400V2~ 400V2~ Heat output [W] 500 800 1000 1200 500 800 1000 1200

3
Weight [kg] 6 6 6 6 6 6 6 6

LxWxD [mm] 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90

Accessories - PFE/PFD
Type PFFAL PFFS Description Front, brushed aluminium Floor stand

54

Convectors

TWT

TWTC

ThermoWarm
ThermoWarm is a range of very compact and easily positioned radiators with ribbed flanges and encased tube elements suitable for public premises such as dressing rooms, stockrooms and rest rooms. The TWTC can also be used in corrosive and aggressive environments. The ribbed flanges provide the radiators with a large heatemitting surface, and thus, a lower surface temperature. The TWT200 has a covered front which reduces the surface temperature further, to 60 C. All models are easily mounted on the wall and have a thermostat with a setting range of 035 C. The front plate is easy to remove for cleaning. A resetable overheat protection covers the whole length of the unit and it releases if the convector is covered. Colour TWT100 and TWT300: white, RAL 9016, grey end caps Colour TWT200: grey covered front, grey end caps Colour TWTC: front in stainless steel, black end caps CE compliant.

Bench heater
Bench heaters are designed for permanent mounting under church pews, waiting room benches etc. Outer and inner reflectors give downward heat dispersion. Equipped with stainless steel tube elements and protection grille. Approved for serial connection. The unit is to be mounted with brackets (included). Colour: grey CE compliant.

Bench heater (IP21)


Type SH17521 SH17531 SH25021 SH25031 SH37521 SH37531 *) With brackets

3
Heat output [W] 175 175 250 250 375 375 LxH*xD [mm] 700x110x200 700x110x200 1000x110x200 1000x110x200 1500x110x200 1500x110x200 Weight [kg] 1,4 1,4 1,9 1,9 2,9 2,9

Voltage [V] 230V~ 400V2~ 230V~ 400V2~ 230V~ 400V2~

TWT100 (IP44) white, with switch


Type TWT10321 TWT10331 TWT10521 TWT10531 TWT11021 TWT11031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~

3
LxWxD [mm] 345x205x123 345x205x123 465x205x123 465x205x123 765x205x123 765x205x123 Weight [kg] 1,5 1,5 2,0 2,0 3,0 3,0

Heat output [W] 300 300 500 500 1000 1000

TWT200 (IP44) covered front, with switch, 60 C


Type TWT20321 TWT20331 TWT20521 TWT20531 TWT21021 TWT21031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 300 500 500 1000 1000

3
Weight [kg] 1,5 1,5 2,0 2,0 3,0 3,0

TWT300 (IP21) white, cable and plug


Type TWT30321 TWT30521 TWT31021 Voltage [V] 230V~ 230V~ 230V~

3
LxWxD [mm] 345x205x123 465x205x123 765x205x123 Weight [kg] 1,5 2,0 3,0

Heat output [W] 300 500 1000

TWTC (IP54) stainless steel, cable and plug,


Type TWTC30321 TWTC30521 TWTC31021 Voltage [V] 230V~ 230V~ 230V~ Heat output [W] 300 500 1000

3
Weight [kg] 1,5 2,0 3,0

LxWxD [mm] 345x205x123 465x205x123 765x205x123

55

Co nvecto r s

LxWxD [mm] 345x205x123 345x205x123 465x205x123 465x205x123 765x205x123 765x205x123

Thermostats and controls


The control system is the intelligent centre and the brain of a heating system and essential for good comfort level and low energy consumption. The temperature of an electric heating system can be quickly, easily and precisely regulated and is more responsive than any other heating system. Frico offers a wide range of thermostats and controls, read more under each product or in the Frico catalogues.

RTI2

RTI2V

CBT

KUR

RTI, electronic thermostats


RTI2 is an electronic 2-step thermostat with alternating voltfree contacts. Controls the heat output. Adjustable temperature difference between the steps (110 C), night time reduction (110 C) can be activated by an externally connected contact, such as a weekly timer. External sensor (RTS01, see below) can also be connected. RTI2V is similar to RTI2, but with external dial (knob). IP44.
Type RTI2 RTI2V Voltage [V] 230V~ 230V~ Setting range [C] 5 - +35 5 - +35 HxWxD [mm] 155x87x43 155x87x43

CBT, electronic timer


Electronic timer with alternating contact. Setting range 1/2-1-2-4 or 4-8-16-24 hours respectively. The setting range can be limited down to a maximum time of 1/2 hour. Max breaking current 16 A. IP44. CE compliant.
Type CBT Voltage [V] 230V~ HxWxD [mm] 155x87x43

KUR, digital time switch


Accessories
Type RTS01 Description External floor/duct sensor

Digital weekly time switch with 8 program steps (36 storage positions). Alternating contact. Max breaking current 10 A. IP44. CE compliant.
Type KUR Voltage [V] 230V~ HxWxD [mm] 155x87x43

56

Thermostats and controls

T10

TK10

TKS16(400)

TD10

KRT1900

KRTV19

KRT2800

T, TK, TD thermostats
Processor controlled thermostats for room/floor heating. Available with concealed/visible knob or digital display. Model with visible knob also available with switch and in 400 V. On/off control (for slow systems) or proportional control (for faster systems) in the same thermostat. TD10 has adjustable P-band and time of cycle. Internal and/or external sensors (external sensor RTS01 available as an accessory) give the possibility of selecting the sensor function e.g limiting external sensors (min/max). Save reduction either by built-in manual switch or via external timer. CE compliant.

Capillary tube thermostats with alternating contacts


For the control of heating and cooling, valves and fans. The housing is of thermal plastic. For 230/400 V and approved for 16 A at 230 V and 10 A at 400 V. KRT1900 and KRT1901 have internal dial. IP55. KRTV19 has an external dial with an adjustable stop for the maximum setting. IP44.
Type KRT1900 KRT1901 KRTV19 Voltage [V] 230/400V~ 230/400V~ 230/400V~ Setting range [C] 0 - +40 -35 - +10 0 - +40 HxWxD [mm] 165x57x60 165x57x60 165x57x60

Type T10 TK10 TKS16 TKS16400 TD10

Voltage [V] 230~ 230~ 230~ 400V2~ 230V~

Max input [A] 10 10 16 16 10

Setting range [C] 5 - +30 5 - +30 5 - +30 5 - +30 5 - +37

HxWxD [mm] 80x80x31 80x80x31 80x80x39 80x80x39 80x80x31

2-step thermostat capillary tube with alternating contacts


Two-step control is appropriate for the gentle and economical control of heat output in fan heaters and air curtains. KRT 2800 has an adjustable temperature difference between the steps (14 C). For 230/400 V and approved for 16 A at 230 V and 10 A at 400 V. IP55.
Type KRT2800 Voltage [V] 230/400V~ Setting range [C] 0 - +40 HxWxD [mm] 165x57x60

Accessories
Type RTS01 Description External floor/duct sensor

Functions

| Thermostats
Basic offer T10 TK10 X X* X* X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TKS16 TKS16400 X X* X* X X X X X X X X X X X X X X X TD10 X X* X* Electronic 2-step RTI2 X X* X* RTI2V X X* X* Capillary tube KRT1900 KRT1901 X KRTV19 X KRT2800 X

Internal sensor External sensor Save reduction 1-pole switch Volt free contact Contact, 1-pole closing Contact, 1-pole alternating Digital display Advanced extra functions* Internal setting Processor controlled Capillary tube Fits wall box system Heating or cooling function 2-step Adjustable temp.diff. between the steps *) External sensor (RTS01) as accessory. *) Can be used with an external timer. *) See manuals on www.frico.se.

X X* X*

57

Ther most at s an d cont rol s

Water controls
VR20/25

AV20/25

JVF20/25

TRV20/25

BPV10

SD20

SD20

TVV20/25

VR20/25

AV20/25

VR20/25

AV20/25

JVF20/25 TRV20/25 T10/KRT


C

BPV10 JVF20/25 SD20 TRV20/25 T10/KRT


C

BPV10 SD20

TVV20/25 SD20 T10/KRT


C

TVV20/25 SD20 T10/KRT


C

230V ~

230V ~

230V ~

230V ~

VR 20/25, valve set


For control of water flow to water heated air curtains. The valve set consists of the following: AV20/25, stop valve JVF20/25, adjustment valve TRV20/25, on/off 3-way control valve BPV10, by-pass valve SD20. actuator on/off 230V~ The stop valve (AV20/25) consists of a ball valve which is either open or closed. It is used to turn the water flow off and on. The water flow can be fine-tuned manually with the adjustment valve and can also be completely turned off. The water flow may be read off the valve. The kv value for JVF20 is 3,5 and for JVF25 it is 5,5. If the 3-way valve (TRV20/25) is closed, the flow through the by-pass valve is low to ensure presence of warm water in the heating coil. This leads to instant heat supply when needed and some degree of frost protection. The actuator (SD20) works on/off. The valve set is available with two different valve dimensions: VR 20 - DN20 (3/4) and VR 25 - DN25 (1). The by-pass valve dimension is DN10 (3/8). To regulate VR20/25, a suitable thermostat has to be added.

TVV20/25, 2-way control valve


TVV20 has a pipe dimension of DN20 (3/4) and TVV25 of DN25 (1). Pressure class PN16. Maximum pressure 2 MPa (20 bar). Maximum pressure drop TVV20: 100 kPa (1 bar) Maximum pressure drop TVV25: 62 kPa (0,62 bar) The kv-value is adjustable in 3 steps:
Pos 1 TVV20 TVV25 kv 1,6 kv 2,5 Pos 2 kv 2,5 kv 4,0 Pos 3 kv 3,5 kv 5,5

SD20, actuator on/off 230V~


SD20 regulates the heat supply. Works on/off. A 5 second closing of the valve prevents sudden pressure changes in the pipe system. IP40. TVV20/25, 2-way regulation valve and SD20, actuator provides a basic form of water regulation, without the possibility of adjusting or shutting the water flow off, e.g. when making maintenance. A suitable thermostat is chosen to regulate TVV20/25 and SD20.

58

Technical data

Symbols for model types = normal design (no symbols), IPX0 = drip-proof design, IPX1 = splash-proof design, IPX4 = jet-proof design, IPX5 Protection classes for electrical material
IP first figure , 0 1 2 3 4 5 6 IP second figure , 0 1 2 3 4 5 6 7 8 Protection against solid objects No protection Protection against solid objects 50 mm Protection against solid objects 12,5 mm Protection against solid objects 2,5 mm Protection against solid objects 1,0 mm Protection against dust Dust-tight Protection against water No protection Protection against vertically dripping water Protection against dripping water angled at max 15 Protection against sprinkled water Protection against spraying with water Protection against water jets Protection against heavy seas Protection against short-term immersion in water Protection against the effects of long-term immersion in water

Heat insulation, U-value U = thermal transmittance value [W/mC] U-values indicate the heat insulating capacity of a building section.

Material Walls Single brick 12 cm 1 1/2 brick 18 cm Light concrete block 20 cm Light concrete block 30 cm Concrete 15 cm Concrete with 5 cm insulation Concrete with 10 cm insulation Frame wall with 5 cm insulation Frame wall with 10 cm insulation Frame wall with 15 cm insulation New construction Roof Concrete beam frame 15 cm Concrete beam frame with 5 cm insulation Concrete beam frame with 10 cm insulation Light concrete 20 cm Light concrete 30 cm Sheet metal roof, uninsulated Sheet metal roof with 5 cm insulation Sheet metal roof with 10 cm insulation Sheet metal roof with 25 cm insulation New construction Windows 1 pane window 2 pane window 3 pane window 3 pane window insulation pane

U-value [W/mC] 1,8 1,1 0,8 0,6 2,8 0,8 0,4 0,8 0,4 0,3 0,3 2,8 0,8 0,4 0,8 0,6 4,0 0,8 0,2 0,2

How is sound measured? Sound level is measured in decibels (dB). The dB is a logarithmic unit used to describe a ratio. If the sound level is increased by 10 dB, the result is twice as loud (as perceived by human ear). It is also useful to know that two equally strong sound sources give an added sound level of 3 dB. Assume you have two entrances with two air curtains in each entrance, all four units with a sound level of 50 dB. The total sound level will then be 56 dB. The first opening will have a total sound level of 53 dB plus an extra 3 dB from the other opening. Points of reference dB 0 10 30 40 50 60 80 85 110 120 The softest sound a person can hear Normal breathing Recommended max. level for bedrooms Quiet office, library Large office Normal conversation Ringing telephone Noisy restaurant Shouting in ear The threshold of pain

5,0 3,0 2,0 1,8

The sound level is stated for each product in the mini catalogue. Our sound measurements are done according to international standards BS 848, AMCA standard 210-85 and DIN 24 163, (the distance to the product 5 metres, directional factor 2, equivalent absorption area 200 m).

59

Frico Radiant Heating


BSS codes - Air curtains and Convectors
BOSS Modular Air Curtains
Model BSS Code 59017160 59017201 59017234 59017267 Price 313.00 471.00 810.00 1,213.00

Frico Convectors
Model BSS Code BSS Code Price Price 39.00 158.00 31.00 187.00 50.00 215.00 58.00 225.00 93.00 231.00 116.00 260.00 39.00 292.00 75.00 215.00 192.00 335.00 220.00 31.00 97.00 38.00 37.00 39.00 51.00

Ambient Overdoor Air Curtain


BOSS S10-100A BOSS S10-150A BOSS S15-100A BOSS S15-150A

Ribbed Pipe Radiator Air Curtain Controls and Accessories


CB30 WATER/AMBIENT 59017939 125-12B 230V 200WATTSWITCH BOX 59032000 RTE 102 ROOM THERMOSTAT 59017865 125-22B 230V 375WATT 59032011 SB ELECTRIC 575WATT 59017928 125-32B 230VSWITCH BOX 59032022 TS2 ELECTRONIC THERMOSTAT 59017876 125-42B 230V 775WATT 59032033 MDC MAGNETIC DOOR CONTACT 59017887 126-32B 230V 575WATT 59032044 SBMS BMS INTERFACE 24V ON/OFF 59017898 126-42B 230V 775WATT 59032055 ADPF1 CEILING BRACKETS 59017906 126-52B 230V 1150WATT 59032066 ADPK SUSPENSION SET COMPLETE 59017917 127-22B 230V 500WATT 59032077 VR 20 VALVE SET 59018088 127-42B 230V 800WATT 59032088 VR 25 VALVE SET 59018099 AGB304 DOOR CONTACT-INDUSTL DR 59018107 Frost Guard PROTECTION AXP300 COLLISION 59018118 FMS200 230V 200WATT 59032107 * VR20 / VR25 Valve sets recommended to control water heated Air Curtains. FML200 230V 200WATT 59032118 FML300 230V 300WATT 59032129 FML450 230V 450WATT 59032140

Electrically Heated Overdoor Air Curtain


BOSS S10-100E Max 9kw BOSS S10-150E Max 13.5kw BOSS S15-100E Max 12kw BOSS S15-150E Max 18kw 59017171 59017212 59017245 59017278 535.00 760.00 993.00 1,454.00

Water Heated Overdoor Air Curtain


BOSS S10-100W 8.4kw BOSS S10-150W 13.2kw BOSS S15-100W 18.6kw BOSS S15-150W 27.8kw 59017182 59017223 59017256 59017289 525.00 785.00 956.00 1,430.00

Electrically Heated Recessed Air Curtain


BOSS S10-100ER Max 9kw BOSS S10-150ER Max 13kw BOSS S10-200ER Max 18kw BOSS S15-100ER Max 12kw BOSS S15-150ER Max 18kw BOSS S15-200ER Max 24kw 59017684 59017695 59017703 59017791 59017780 59017810 822.00 1,125.00 1,583.00 1,368.00 1,952.00 2,620.00

Fan Convector PF and Accessories


PFE5 230V 500WATT PFE8 230V 800WATT PFE10 230V 1000WATT PFE12 230V 1200WATT PFD5 400V 500WATT PFD8 400V 800WATT PFD10 400V 1000WATT PFD12 400V 1200WATT PFFAL FRONT BRUSHED ALUMINIUM PFFS FLOOR STAND 59032609 59032620 59032631 59032642 59032653 59032664 59032675 59032686 59032801 59032812 139.00 145.00 155.00 165.00 146.00 157.00 165.00 180.00 33.00 20.00

Water Heated Recessed Air Curtain


BOSS S10-100WR 8.4kw BOSS S10-150WR 13.2kw BOSS S10-200WR 16.8kw BOSS S15-100WR 18.6kw BOSS S15-150WR 27.8kw BOSS S15-200WR 37.2kw 59017651 59017662 59017673 59017714 59017725 59017736 809.00 1,101.00 1,557.00 1,343.00 1,913.00 2,585.00

Thermowarm

Page 483 < BACK

to main menu > NEXT page > PREVIOUS Architectural Range Stainless Steel Electrically Heated
BOSS LP-1000ESS Max 9kw BOSS LP-1500ESS Max 12kw BOSS LP-2000ESS Max 18kw BOSS LP-2500ESS Max 21kw BOSS LP-3000ESS Max 24kw 59018044 59017566 59017599 59017629 59018066 1,960.00 2,685.00 3,710.00 4,650.00 5,555.00

page

Range

Architectural Range Stainless Steel Water Heated


BOSS LP-1000WSS Max 10kw* BOSS LP-1500WSS Max 20kw* BOSS LP-2000WSS Max 20kw* BOSS LP-2500WSS Max 20kw* BOSS LP-3000WSS Max 30kw* *LP HW at 82/71c 59018055 59017577 59017607 59017640 59018077 1,705.00 2,425.00 3,457.00 4,395.00 5,300.00

Industrial Heated
Price 313.00 471.00 810.00 1,213.00 Air Curtains for doorways inModel of 4.0m in height are available, contact the excess BSS Code Price BSS Technical Team at Fleet House for a solution to fit your specification/requirements.

Air Curtain Controls and Accessories

535.00 760.00 993.00 1,454.00

525.00 785.00 956.00 1,430.00

CB30 WATER/AMBIENT SWITCH BOX 59017939 RTE 102 ROOM THERMOSTAT 59017865 SB ELECTRIC SWITCH BOX 59017928 TS2 ELECTRONIC THERMOSTAT 59017876 MDC MAGNETIC DOOR CONTACT 59017887 SBMS BMS INTERFACE 24V ON/OFF 59017898 ADPF1 CEILING BRACKETS 59017906 ADPK SUSPENSION SET COMPLETE 59017917 VR 20 VALVE SET 59018088 VR 25 VALVE SET 59018099 AGB304 DOOR CONTACT-INDUSTL DR 59018107 483 AXP300 COLLISION PROTECTION 59018118 * VR20 / VR25 Valve sets recommended to control water heated Air Curtains.

web: web: www.bssuk.co.uk 531 email: enquiries@bssgroup.com www.bssuk.co.uk e

39.00 31.00 50.00 58.00 93.00 116.00 39.00 75.00 192.00 220.00 31.00 97.00

A full range of trench and perimeter heating is available through BSS. Contact Bench Heater the BSS Technical Support Team SH17521 230V 175WATT 59032502 81.00 or your local BSS branch. SH17531 400V 175WATT 59032513 81.00
SH25021 230V 250WATT 59032524 SH25031 400V 250WATT 59032535 BSS TECHNICAL SUPPORT TEAM SH37521 230V 375WATT 59032546 SH37531 400V 375WATT TEL: 0116 256 7052 59032557 92.00 92.00 107.00 107.00

TWT10321 WHITE C/W SWITCH 230V 300WATT TWT10331 WHITE C/W SWITCH 400V 300WATT TWT10521 WHITE C/W SWITCH 230V 500WATT TWT10531 WHITE C/W SWITCH 400V 500WATT TWT11021 WHITE C/W SWITCH 230V 1000WATT TWT11031 WHITE C/W SWITCH 400V 1000WATT TWT20321 COVERED FRONT CW SWITCH 230V 300WATT TWT20331 COVERED FRONT CW SWITCH 400V 300WATT TWT20521 COVERED FRONT CW SWITCH 230V 500WATT TWT20531 COVERED FRONT CW SWITCH 400V 500WATT TWT21021 COVERED FRONT CW SWITCH 230V 1000WATT TWT21031 COVERED FRONT CW SWITCH 400V 1000WATT TWT30321 WHITE,CABLE & PLUG 230V 300WATT TWT30521 WHITE,CABLE & PLUG 230V 500WATT TWT31021 WHITE,CABLE & PLUG 230V 1000WATT TWTC30321 S/S,CABLE & PLUG 230V 300WATT TWTC30521 S/S,CABLE & PLUG 230V 500WATT TWTC31021 S/S,CABLE & PLUG 230V 1000WATT

TRENCH AND PERIMETER HEATING

59032203 59032214 59032225 59032236 59032247 59032258 59032269 59032280 59032291 59032310 59032321 59032332 59032343 59032354 59032365 59032376 59032387 59032398

69.00 69.00 72.00 72.00 75.00 75.00 72.00 72.00 74.00 74.00 80.00 80.00 72.00 73.00 74.00 150.00 172.00 187.00

FAX: 0116 256 7453 EMAIL: technicalheatingteam@bssgroup.com

822.00 1,125.00

60

Frico Radiant Heating Frico Radiant Heating


BSS codes - Radiant heaters
Frico Radiant Heaters Frico Radiant Heaters
Model Model BSS Code BSS Code 59030007 59030007 59030018 59030018 59030029 59030029 59030040 59030040 59030051 59030051 59030062 59030062 59030073 59030073 59030084 59030084 Price Price 68.00 68.00 68.00 68.00 86.00 86.00 86.00 86.00 92.00 92.00 92.00 92.00 105.00 105.00 105.00 105.00 Model Model BSS Code BSS Code 59030638 59030638 59030649 59030649 59030660 59030660 59030671 59030671 Price Price 71.00 71.00 42.00 42.00 14.00 14.00 51.00 51.00

Thermoplus EC for Dry rooms Thermoplus EC for Dry rooms


EC45021 230V 450WATT EC45021 230V 450WATT EC45031 400V 450WATT EC45031 400V 450WATT EC60021 230V 600WATT EC60021 230V 600WATT EC60021 400V 600WATT EC60021 400V 600WATT EC75021 230V 750WATT EC75021 230V 750WATT EC75031 400V 750WATT EC75031 400V 750WATT EC90021 230V 900WATT EC90021 230V 900WATT EC90031 400V 900WATT EC90031 400V 900WATT

Elztrip Accessories Elztrip Accessories


CIRT STEPLESS OUTPUT CONTROL WITH TIMER CIRT STEPLESS OUTPUT CONTROL WITH TIMER TK10 ROOM THERMOSTAT DIGITAL CONTROL TK10 ROOM THERMOSTAT DIGITAL CONTROL EZMVK WALL MOUNTING BRACKET EZMVK WALL MOUNTING BRACKET S123 MANUAL SWITCH FOR 1-2-3 STEPS S123 MANUAL SWITCH FOR 1-2-3 STEPS

Industrial Infrared Heater IR Industrial Infrared Heater IR


IR3000 400V 3000WATT IR3000 400V 3000WATT IR4500 400V 4500WATT IR4500 400V 4500WATT IR6000 400V 6000WATT IR6000 400V 6000WATT 59030701 59030701 59030712 59030712 59030723 59030723 226.00 226.00 245.00 245.00 275.00 275.00

Thermoplus EC for Wet rooms Thermoplus EC for Wet rooms


ECV30021 230V 300WATT ECV30021 230V 300WATT ECV55021 230V 550WATT ECV55021 230V 550WATT ECV55031 400V 550WATT ECV55031 400V 550WATT ECV70021 230V 700WATT ECV70021 230V 700WATT ECV70031 400V 700WATT ECV70031 400V 700WATT ECVT30021 AS SLAVE 300WATT ECVT30021 AS SLAVE 300WATT ECVT55021 AS SLAVE 550WATT ECVT55021 AS SLAVE 550WATT ECVT55031 AS SLAVE 550WATT ECVT55031 AS SLAVE 550WATT ECVT70021 AS SLAVE 700WATT ECVT70021 AS SLAVE 700WATT ECVT70031 AS SLAVE 700WATT ECVT70031 AS SLAVE 700WATT 59030095 59030095 59030103 59030103 59030114 59030114 59030125 59030125 59030136 59030136 59030147 59030147 59030158 59030158 59030169 59030169 59030180 59030180 59030191 59030191 69.00 69.00 94.00 94.00 94.00 94.00 99.00 99.00 99.00 99.00 105.00 105.00 124.00 124.00 124.00 124.00 135.00 135.00 135.00 135.00

Infrared Heater IRCF Infrared Heater IRCF


IRCF15 230V 1500WATT IRCF15 230V 1500WATT IRCF30 230V 3000WATT IRCF30 230V 3000WATT IRCF45 230/400V 6000WATT IRCF45 230/400V 6000WATT 59030789 59030789 59030808 59030808 59030819 59030819 160.00 160.00 275.00 275.00 402.00 402.00

Infrared Accessories Infrared Accessories


TK10 ROOM THERMOSTAT WITH KNOB TK10 ROOM THERMOSTAT WITH KNOB CBT ELECTRONIC TIMER CBT ELECTRONIC TIMER IRG3000 PROTECTION GRILL IRG3000 PROTECTION GRILL IRG4500 PROTECTION GRILL IRG4500 PROTECTION GRILL IRG6000 PROTECTION GRILL IRG6000 PROTECTION GRILL LIRCF EXTRA LAMP LIRCF EXTRA LAMP GIR15 PROTECTION GRILL IRCF30/IRCF15/IRCF45 GIR15 PROTECTION GRILL IRCF30/IRCF15/IRCF45 GIR30 PROTECTION GRILL IRCF30 GIR30 PROTECTION GRILL IRCF30 IRC13 INFRARED HEATER 1300WATT IRC13 INFRARED HEATER 1300WATT IRT EXTRA LAMP IRT EXTRA LAMP 59030734 59030734 59030745 59030745 59030756 59030756 59030767 59030767 59030778 59030778 59030830 59030830 59030841 59030841 59030852 59030852 59030863 59030863 59030874 59030874 31.00 31.00 53.00 53.00 43.00 43.00 50.00 50.00 53.00 53.00 69.00 69.00 30.00 30.00 28.00 28.00 245.00 245.00 59.00 59.00

Thermoplus Accessories Thermoplus Accessories


TF1 FIXTURES CEILING MOUNTING TF1 FIXTURES CEILING MOUNTING OS1 PROTECTION NET 1070MM OS1 PROTECTION NET 1070MM OS2 PROTECTION NET 1500MM OS2 PROTECTION NET 1500MM 59030210 59030210 59030221 59030221 59030232 59030232 15.00 15.00 20.00 20.00 20.00 20.00

Thermocassette HP Thermocassette HP
HP300 230V 300WATT HP300 230V 300WATT HP600 230V 600WATT HP600 230V 600WATT HP305 230V 300WATT HP305 230V 300WATT HP605 230V 600WATT HP605 230V 600WATT 59030306 59030306 59030317 59030317 59030328 59030328 59030339 59030339 108.00 108.00 152.00 152.00 119.00 119.00 176.00 176.00

Infrared Heater CIR Infrared Heater CIR


CIR10521 230V 500WATT W/O SWITCH CIR10521 230V 500WATT W/O SWITCH CIR11021 230V 1000WATT W/O SWITCH CIR11021 230V 1000WATT W/O SWITCH CIR11031 400V 1000WATT W/O SWITCH CIR11031 400V 1000WATT W/O SWITCH CIR11521 230V 1500WATT W/O SWITCH CIR11521 230V 1500WATT W/O SWITCH CIR11531 400V 1500WATT W/O SWITCH CIR11531 400V 1500WATT W/O SWITCH CIR12021 230V 2000WATT W/O SWITCH CIR12021 230V 2000WATT W/O SWITCH CIR12031 400V 2000WATT W/O SWITCH CIR12031 400V 2000WATT W/O SWITCH CIR20521 230V 500WATT C/W SWITCH CIR20521 230V 500WATT C/W SWITCH CIR21021 230V 500WATT C/W SWITCH CIR21021 230V 500WATT C/W SWITCH CIR21031 400V 1000WATT C/W SWITCH CIR21031 400V 1000WATT C/W SWITCH CIR21531 400V 1500WATT C/W SWITCH CIR21531 400V 1500WATT C/W SWITCH CIR22031 400V 2000WATT C/W SWITCH CIR22031 400V 2000WATT C/W SWITCH 59030904 59030904 59030915 59030915 59030926 59030926 59030937 59030937 59030948 59030948 59030959 59030959 59030970 59030970 59030981 59030981 59030992 59030992 59031009 59031009 59031020 59031020 59031031 59031031 44.00 44.00 58.00 58.00 58.00 58.00 65.00 65.00 65.00 65.00 75.00 75.00 75.00 75.00 63.00 63.00 71.00 71.00 71.00 71.00 84.00 84.00 91.00 91.00

Thermocassette Accessories Thermocassette Accessories


ERP ELECTRIC HEATING CONTROL PANEL ERP ELECTRIC HEATING CONTROL PANEL ERPS ELECTRIC HEATING CONTROL SLAVE ERPS ELECTRIC HEATING CONTROL SLAVE T10 ROOM THERMOSTAT T10 ROOM THERMOSTAT TKS16 ROOM THERMOSTAT WITH KNOB TKS16 ROOM THERMOSTAT WITH KNOB KRT1900 ROOM THERMOSTAT KRT1900 ROOM THERMOSTAT SKB10 SHELTER BARS SKB10 SHELTER BARS 74701 WIRE MOUNTING KIT 74701 WIRE MOUNTING KIT 59030350 59030350 59030361 59030361 59030372 59030372 59030383 59030383 59030394 59030394 59030402 59030402 59030413 59030413 60.00 60.00 60.00 60.00 31.00 31.00 44.00 44.00 58.00 58.00 28.00 28.00 15.00 15.00

Elztrip EZ100 & EZ200 Elztrip EZ100 & EZ200


EZ106 230V 600WATT EZ106 230V 600WATT EZ111 230V 1050WATT EZ111 230V 1050WATT EZ115 230V 1500WATT EZ115 230V 1500WATT EZ208 230V 800WATT EZ208 230V 800WATT EZ20831 400V 800WATT EZ20831 400V 800WATT EZ212 230V 1200WATT EZ212 230V 1200WATT EZ21231 400V 1200WATT EZ21231 400V 1200WATT EZ217 230V 1700WATT EZ217 230V 1700WATT EZ21731 400V 1700WATT EZ21731 400V 1700WATT EZ222 230V 2200WATT EZ222 230V 2200WATT EZ22231 400V 2200WATT EZ22231 400V 2200WATT EZ336 3600WATT EZ336 3600WATT 59030509 59030509 59030520 59030520 59030531 59030531 59030542 59030542 59030553 59030553 59030564 59030564 59030575 59030575 59030586 59030586 59030597 59030597 59030605 59030605 59030616 59030616 59030627 59030627 87.00 87.00 116.00 116.00 121.00 121.00 110.00 110.00 110.00 110.00 132.00 132.00 132.00 132.00 165.00 165.00 165.00 165.00 176.00 176.00 176.00 176.00 280.00 280.00

Infrared Heater ELIR Infrared Heater ELIR


ELIR12 230V 1200WATT ELIR12 230V 1200WATT 59031042 59031042 139.00 139.00

Infrared Heater ELIR Accessories Infrared Heater ELIR Accessories


ELIRC CHAIN FOR CEILING MOUNT ELIRC CHAIN FOR CEILING MOUNT ELIRS FLOOR STAND ELIRS FLOOR STAND ELIRB UNIVERSAL BRACKET ELIRB UNIVERSAL BRACKET IREL EXTRA LAMP IREL EXTRA LAMP 59031053 59031053 59031064 59031064 59031075 59031075 59031086 59031086 18.00 18.00 42.00 42.00 22.00 22.00 53.00 53.00

529 529

web: www.bssuk.co.uk email: enquiries@bssgroup.com web: www.bssuk.co.uk email: enquiries@bssgroup.com

61

Frico Radiant Heating Frico Radiant Heating


BSS codes - Fan heaters
Frico Fan Heaters Frico Fan Heaters
Model Model BSS Code BSS Code 59031097 59031097 Price Price 90.00 90.00 Model Model BSS Code BSS Code 59031791 59031791 59031810 59031810 59031821 59031821 59031832 59031832 59031843 59031843 59031854 59031854 59031865 59031865 59031876 59031876 59031887 59031887 59031898 59031898 59031906 59031906 59031917 59031917 59031928 59031928 59031939 59031939 59031950 59031950 59031961 59031961 59031972 59031972 Price Price 50.00 50.00 58.00 58.00 62.00 62.00 295.00 295.00 220.00 220.00 262.00 262.00 655.00 655.00 205.00 205.00 64.00 64.00 81.00 81.00 315.00 315.00 325.00 325.00 57.00 57.00 261.00 261.00 70.00 70.00 58.00 58.00 72.00 72.00

Fan Heater K21 Fan Heater K21


PORTABLE FAN HEATER 230V 2KW PORTABLE FAN HEATER 230V 2KW

Fan Heater Panther Accessories Fan Heater Panther Accessories


PP15 CONTROL PANEL SE06-15 PP15 CONTROL PANEL SE06-15 PP20 CONTROL PANEL SE20 PP20 CONTROL PANEL SE20 PP30 CONTROL PANEL SE30 PP30 CONTROL PANEL SE30 PTA01 AUTO TEMP REG SE06-15 PTA01 AUTO TEMP REG SE06-15 PBS01 MIXING CABLE SE06-15 PBS01 MIXING CABLE SE06-15 PBS02 MIXING CABLE SE20 SE30 PBS02 MIXING CABLE SE20 SE30 PSA01 DAMPER AND AUTO TEMP REG PSA01 DAMPER AND AUTO TEMP REG PSM01 DAMPER MOTOR FOR MIXING CABLE PSM01 DAMPER MOTOR FOR MIXING CABLE PLR15 DEFLECTOR SE06-15 PLR15 DEFLECTOR SE06-15 PLR30 DEFLECTOR SE20 SE30 PLR30 DEFLECTOR SE20 SE30 PFF15 EXHAUST FAN 1400M3/H PFF15 EXHAUST FAN 1400M3/H PFF30 EXHAUST FAN 2600M3/H PFF30 EXHAUST FAN 2600M3/H PHR01 CTRL LEVER FOR MIXING CABINET PHR01 CTRL LEVER FOR MIXING CABINET PTRP DRYING ROOM KIT W/O FAN HEATER PTRP DRYING ROOM KIT W/O FAN HEATER KRT2800 22STEP THERMOSTAT KRT2800 STEP THERMOSTAT RT12 22STEP THERMOSTAT RT12 STEP THERMOSTAT RT12V 22STEP THERMOSTAT WITH KNOB RT12V STEP THERMOSTAT WITH KNOB

Fan Heater Tiger Fan Heater Tiger


P21 230V 2KW P21 230V 2KW P31 230V 3KW P31 230V 3KW P3110-UK 110V 3KW P3110-UK 110V 3KW P33 400V 3KW P33 400V 3KW P53 400V 5KW P53 400V 5KW P93 400V 9KW P93 400V 9KW P153 400V 15KW P153 400V 15KW P203 400V 20KW P203 400V 20KW P303 400V 30KW P303 400V 30KW P305 400V 30KW P305 400V 30KW 59031201 59031201 59031212 59031212 59031223 59031223 59031234 59031234 59031245 59031245 59031256 59031256 59031267 59031267 59031278 59031278 59031289 59031289 59031308 59031308 133.00 133.00 169.00 169.00 215.00 215.00 176.00 176.00 190.00 190.00 225.00 225.00 335.00 335.00 565.00 565.00 635.00 635.00 754.00 754.00

Fan Heater Cat Fan Heater Cat


C3 WALL MOUNTED FAN HTR 3KW C3 WALL MOUNTED FAN HTR 3KW C5 WALL MOUNTED FAN HTR 5KW C5 WALL MOUNTED FAN HTR 5KW C9 WALL MOUNTED FAN HTR 9KW C9 WALL MOUNTED FAN HTR 9KW 59031404 59031404 59031415 59031415 59031426 59031426 195.00 195.00 195.00 195.00 260.00 260.00

Fan Heater Cat Accessories Fan Heater Cat Accessories


EV300 OUTPUT SELECTOR EV300 OUTPUT SELECTOR KUR DIGITAL TIMER SWITCH KUR DIGITAL TIMER SWITCH CMB305 MIXING CABINET CMB305 MIXING CABINET TP3/5 COVER PANEL SWITCHES C3/C5 TP3/5 COVER PANEL SWITCHES C3/C5 TP9 COVER PANEL SWITCHES C9 TP9 COVER PANEL SWITCHES C9 59031437 59031437 59031448 59031448 59031459 59031459 59031470 59031470 59031481 59031481 30.00 30.00 100.00 100.00 138.00 138.00 14.00 14.00 11.00 11.00

Fan Heater Elektra Wall Mounted Fan Heater Elektra Wall Mounted
ELC331 ELEKTRA CC230V 3KW ELC331 ELEKTRA 230V 3KW ELC633 ELEKTRA CC400V 6KW ELC633 ELEKTRA 400V 6KW ELC933 ELEKTRA CC230V 3KW ELC933 ELEKTRA 230V 3KW ELC1533 ELEKTRA CC400V 3KW ELC1533 ELEKTRA 400V 3KW ELF331 ELEKTRA FF230V 3KW ELF331 ELEKTRA 230V 3KW ELF633 ELEKTRA FF400V 6KW ELF633 ELEKTRA 400V 6KW ELF933 ELEKTRA FF400V 9KW ELF933 ELEKTRA 400V 9KW ELV3333 ELEKTRA VV400V 3KW ELV3333 ELEKTRA 400V 3KW ELV3344 ELEKTRA VV400V 6KW ELV3344 ELEKTRA 400V 6KW ELV5333 ELEKTRA VV400V 5KW ELV5333 ELEKTRA 400V 5KW ELV6344 ELEKTRA VV400V 6KW ELV6344 ELEKTRA 400V 6KW ELV6344 ELEKTRA VV230V 6KW ELV6344 ELEKTRA 230V 6KW ELH633 ELEKTRA HH400V 6KW ELH633 ELEKTRA 400V 6KW ELH933 ELEKTRA HH400V 9KW ELH933 ELEKTRA 400V 9KW 59031500 59031500 59031511 59031511 59031522 59031522 59031533 59031533 59031544 59031544 59031555 59031555 59031566 59031566 59031588 59031588 59031599 59031599 59031607 59031607 59031618 59031618 59031629 59031629 59031640 59031640 59031651 59031651 610.00 610.00 765.00 765.00 805.00 805.00 875.00 875.00 585.00 585.00 645.00 645.00 735.00 735.00 640.00 640.00 640.00 640.00 710.00 710.00 715.00 715.00 605.00 605.00 732.00 732.00 782.00 782.00

Fan Heater Elektra Accessories Fan Heater Elektra Accessories


ELSRT CONTROL BOX C/W THERMOSTAT ELC/V ELSRT CONTROL BOX C/W THERMOSTAT ELC/V ELS CONTROL BOX ELF ELS CONTROL BOX ELF ELRT ROOM THERMOSTAT ELH ELRT ROOM THERMOSTAT ELH 59031662 59031662 59031673 59031673 59031684 59031684 135.00 135.00 43.00 43.00 128.00 128.00

Fan Heater Panther Fan Heater Panther


SE06 400V 6KW SE06 400V 6KW SE09 400V 9KW SE09 400V 9KW SE12 400V 12KW SE12 400V 12KW SE135 440V 10KW SE135 440V 10KW SE15 400V 15KW SE15 400V 15KW SE20 400V 20KW SE20 400V 20KW SE30 400V 30KW SE30 400V 30KW SE305 440V 23KW SE305 440V 23KW 59031703 59031703 59031714 59031714 59031725 59031725 59031736 59031736 59031747 59031747 59031758 59031758 59031769 59031769 59031780 59031780 418.00 418.00 451.00 451.00 480.00 480.00 600.00 600.00 495.00 495.00 605.00 605.00 650.00 650.00 755.00 755.00

Tel: 0116 262 3232 Fax: 0116 253 1343 Tel: 0116 262 3232 Fax: 0116 253 1343

530 530

62

S-ar putea să vă placă și