7. Gradually change the field rheostat of generator in steps of 0.1A 8. Note down the corresponding readings. 9. Draw the necessary graph. TABULATION : S.No. 1 2 3 4 5 6 7 8 9 Fielfd Current Ish ( I ) Induced e.m.f E0 (v)
Tabulation for Drop Test ( Rsh ):S.No. Voltage (v) Current (A) 1 2 3 4 Average PRECAUTIONS: 1. 2. 3. 4. 5. 6. 7. Model Graph:Rsh = V/I ()
Connections should be tight Take the readings without parallax errors. Fuses should be properly rated. The operation of the 3-Point starter should be slow and uniform. Armature rheostat should be connected in maximum position initially. Field rheostat of motor should be in minimum resistance position. Generator field rheostat should be in the maximum position
Rc A OCC Eo Rsh C P
Q Model Calculations:-
If
Critical Resistance RC = OP/OQ Critical Speed NC = N1 x BC/AC RESULT:The experiment was done on the given D.C. Shunt Generator and its o.c.c. curve is drawn and also critical field resistance and critical speed are calculated.
VIVA QUESTIONS