Sunteți pe pagina 1din 95

GR No.: GR/SDH-07/01.MAR.

2005 for STM -64 Synchronous Multiplexer for Metro Networks

-1-

TRANSMISSION

Generic Requirements for STM-64 Synchronous Multiplexer for ADM & TM Applications for Metro Networks

GENERIC REQUIREMENTS No.: GR/SDH-07/01.MAR.2005

TELECOMMUNICATION ENGINEERING CENTRE


KHURSHID LAL BHAWAN, JANPATH NEW DELHI-110001. INDIA.

TEC 2005

All rights reserved and no part of this publication may be reproduced, stored in a retrieval sy stem or transmitted, in any form and by any means - electronic, mechanical, photocopying, recording, scanning or otherwise, without written permission from the Telecommunication Engineering Centre, New Delhi. -1-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-2-

Document History
Name of the GR STM-64 Synchronous Multiplexer for Terminal Multiplexer & ADM applications No. of the GR GR/SDH-07/01.MAR.2005 Remarks First release

-2-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-3-

INDEX Reference Documents ..............................................................................- 6 PART-I [GENERAL REQUIREMENTS] ...............................................................- 9 1.0 1.3 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 1.0 1.5.1 1.15 1.16 1.16.1 1.16.2 1.16.3 2.0 3.0 4.0 4.1 Introduction..........................................................................- 9 Brief overview of services.........................................................- 9 Reference Documents ............................................................ - 14 Engineering requirements ....................................................... - 15 Operational Requirements....................................................... - 16 Quality Requirements ............................................................ - 16 Maintenance requirements ...................................................... - 17 Power Supply....................................................................... - 17 Accessories ......................................................................... - 18 Documentation .................................................................... - 18 Protection requirements......................................................... - 19 Optical Safety Requirements .................................................... - 19 Optical Access Port ............................................................... - 19 Operating Personnel Safety Requirements ................................... - 20 Electromagnetic Compatibility (EMC).......................................... - 20 Functional requirements......................................................... - 23 Ethernet interfaces: Power-budget specification ........................... - 23 Equipment Redundancy .......................................................... - 26 Construction Practice ............................................................ - 28 Expansion chassis ................................................................. - 28 Cross-connect architecture...................................................... - 28 Universal-slot architecture ...................................................... - 28 Transport media ................................................................... - 28 Performance Requirements ..................................................... - 28 Network Requirements........................................................... - 29 Application topologies............................................................ - 29 -

PART-II [TECHNICAL REQUIREMENTS].......................................................... - 23 -

-3-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-4-

4.1.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5.0 5.1 5.2 5.3 6.0 6.2.3 6.2.4 6.2.4.2 6.2.5 6.2.6 6.3 6.3.1 6.3.1.1 6.3.2 6.3.3 6.3.4 6.4 6.5 6.6 6.8 6.9

Classifications and application codes.......................................... - 29 Network topologies ............................................................... - 29 Equipment configuration......................................................... - 29 Resilience & Protection .......................................................... - 31 System Restoration ............................................................... - 34 Traffic interfaces in M-ADM/ADM/TM configuration......................... - 34 Cross-Connect Capability ........................................................ - 35 Type of connections on SDH path-layer ....................................... - 36 Loop-backs at SDH and MAC Layers ............................................ - 37 System Requirements ............................................................ - 37 Synchronisation.................................................................... - 37 Maintenance, Performance Monitoring and Alarm Signals ................. - 40 Order-wire and User-Data c hannel............................................. - 42 Technical Specifications in details ............................................. - 42 Tandem Connection Monitoring ................................................ - 45 Concatenation & Encapsulation mechanisms................................. - 45 Virtual Concatenation ............................................................ - 45 Generic Framing Procedure ..................................................... - 45 Link Capacity Adjustment Scheme ............................................. - 45 Ethernet Service requirements ................................................. - 46 Layer 2 Service Implementation Requirements ............................. - 47 Service QoS Implementation .................................................... - 48 Layer 2 functionality details & specifications................................ - 49 Layer-2 Switching/Aggregation Implementation............................. - 50 Ethernet Provisioning VCAT details .......................................... - 52 Network Node Interfaces - Details ............................................. - 52 Window of Operation............................................................. - 53 Optical Line Interface : STM-64 interface .................................... - 53 Jitter and Wander Performance................................................ - 54 Optical Tributary Interfaces..................................................... - 55 -

-4-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-5-

6.10 6.13 6.13.2 7.0 8.0 9.0

PDH Tributary Interfaces ........................................................ - 59 Ethernet over SDH (EoS) interface............................................. - 63 Transparent SAN interfaces ..................................................... - 64 Mechanical standards............................................................. - 64 Minimum equipment for testing ................................................ - 66 Field Trial........................................................................... - 67 -

Annexure I ITU-T Parametric Tables Table 1/G.691 - Parameters for STM-64 optical interfaces................................ - 70 Table 2 {Parameters specified for STM-16 optical interfaces] - ITU-T/G.957 ........ - 71 Table-3 [Parameters specified for STM-4 optical interfaces] ITU-T/G.957 ........... - 73 Table- 4 [Parameters specified for STM-1 optical interfaces] ITU-T/G.957........... - 74 Annexure II Ordering Instructions ............................................................. - 76 APPENDIX I EMS Requirements ................................................................ - 77 1.0 1.1 2.0 3.0 4.0 5.0 6.0 7.0 7.1 8.0 8.1 8.2 8.3 8.4 9.0 GLOSSARY Network Management Functions ............................................... - 83 General Functions................................................................. - 83 Configuration Management ...................................................... - 83 Fault Management ................................................................ - 84 Performance Management....................................................... - 84 Security Management............................................................. - 85 Inventory management........................................................... - 86 Software Management............................................................ - 86 Software Download ............................................................... - 87 Management Interface............................................................ - 87 Southbound Interface ............................................................ - 87 Northbound Interface ............................................................ - 87 Local Management Interface .................................................... - 88 User Interface...................................................................... - 88 Embedded Control Channel ..................................................... - 88 ....................................................................................... - 95 -

APPENDIX II VLAN implementation in the M-ADM/ADM equipment ...................... - 92 -

-5-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-6-

Reference Documents
ITU-T Rec.G.691 ITU-T Rec.G.702 ITU-T Rec.G.703 ITU-T Rec.G.707 ITU-T Rec.G.712 ITU-T Rec.G.773 ITU-T Rec.G.774 ITU-T Rec.G.781 ITU-T Rec.G.783 ITU-T Rec.G.784 ITU-T Rec.G.803 ITU-T Rec.G.811 ITU-T Rec.G.812 ITU-T Rec.G.813 ITU-T Rec.G.821 ITU-T Rec.G.823 ITU-T Rec.G.825 ITU-T Rec.G.826 ITU-T Rec.G.828 ITU-T Rec.G.829 ITU-T Rec.G.841 ITU-T Rec.G.957 Optical interfaces for single-channel STM -64, STM-256 systems and other SDH systems with optical amplifiers. Digital hierarchy bit rates. Physical/electrical characteristics of hierarchical digital interfaces. Network node interface for the synchronous digital hierarchy (SDH). Transmission performance characteristics of pulse code modulation channels. Protocol suites for Q interfaces for management of transmission systems. Synchronous digital hierarchy (SDH) management information model for the network Synchronization layer function. Characteristics of SDH equipment functional blocks. Synchronous digital hierarchy (SDH) management. Architecture of transport networks based on the SDH. Timing characteristics of primary reference clocks. Timing requirements of slave clocks suitable for use as node clocks in synchronization. Timing characteristics of SDH equipment slave clocks (SEC) Error performance of an international digital connection operating at a bit rate below the primary rate and forming part of integrated services digital network. The control of jitter and wander within digital networks which are based on the 2048 kb/s hierarchy. The control of jitter and wander within digital networks which are based on the synchronous digital Hierarchy (SDH) Error performance parameters and objectives for international constant bit rate digital paths at or above the primary rate. Error performance events for SDH paths Error performance events for SDH multiplex section and regenerator section Types and characteristics of SDH network protection architectures. Optical interfaces for equipments and systems relating to the synchronous digital hierarchy.

-6-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-7-

ITU-T Rec.Q.811 ITU-T Rec.Q.812 ITU-T Rec.M.2100 ITU-T Rec.M.2101 ITU-T Rec.M.2120 ITU-T Rec.M.3010 ITU-T Rec.G.7041 ITU-T Rec.G.7042 ITU-T Rec.G.7712 ITU-T Rec.X.721 IEC Publication 479-1 IEC Publication 215 IEC Publication 1000-4-2 IEC Publication 1000-4-3 IEC Publication 1000-4-4 IEC Publication 1000-4-6 IS:8437 {1993} IS:13252 {1993} IEEE 802.3 IEEE 802.1 TMF 814, TMF 608, TMF 513

Lower layer protocol profiles for the Q3 and X interfaces Upper layer protocol profiles for the Q3 and X interfaces Performance limits for bringing into service and international PDH paths, sections and transmission systems. Performance limits for bringing into service and maintenance of international SDH paths and multiplex sections. PDH path, section and system and SDH path and multiplex section fault detection and localization procedures. TMN conformance and TMN compliance. Generic Framing Procedure Link Capacity Adjustment Scheme Architecture and specifications for data c ommunication network for management information Information technology -Open systems Interconnection Guide on the effects of current passing through the human body Safety requirements of radio transmitting equipments Testing and measurement techniques of Electrostatic discharge immunity test Radiated RF electromagnetic field immunity test Testing and measurement techniques of electrical fast transients/burst immunity test Immunity to conducted disturbances Guide on the effects of current passing through the human body Safety of information technology equipment including electrical business equipment IEEE Ethernet standards series IEEE Ethernet Bridging standards series TMN Forum Management Standards

-7-

GR No.: GR /SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM -64 bit rates

-8-

Part I General Requirements

-8-

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

-9-

Telecommunication Engineering Centre


K.L. Bhawan, Janpath, New Delhi-110001.

Generic Requirements for Synchronous Multiplexer


(ADM & TM) at STM-64 bit rates for Metro Applications (GR No.:GR/SDH-07/01.MAR.2005)

PART-I [GENERAL REQUIREMENTS] 1.0 1.1 Introduction


This document describes generic requirements and technical specifications for STM-64 Synchronous Multiplexer, for ADM and Terminal Multiplexer applications in metro networks in Indian telecom network. The basic multiplexing principles of the equipment shall be as per ITU-T Rec. G.707 specifications for SDH network node interface (NNI). The equipment shall be designed to work on ITU-T Rec. G.652 Single-Mode Fibre (SMF) as well as ITU-T Rec. G.655 Non-Zero Dispersion Shifted fibre (NZ-DSF) at 1550nm window of operation. The equipment in TM and ADM configurations shall provide a flexible combination of tributary interfaces as listed in clause 4.6 in PART II of the GR. The offered equipment shall support all the essential features and capabilities as outlined in this GR.

1.2

The equipment shall terminate a STM-64 ring on the aggregate interfaces as well as it shall terminate multiple STM-1/4/16 rings at tributary ports subject to cross-connection capacity in the system. An STM-64 aggregate ring formed with the equipment shall consist of a flexible mix of TDM portion (drop/add of 2Mbps, 34Mbps/DS3, STM-1/4/16 tributaries), Point to point-VCAT channels, Point to multipoint-VCAT channels and Multipoint to multipoint-VCAT channels. It is recommended that the boundaries between these service-groups shall be software provisioned using same interfaces/line-cards thus facilitating dynamic adjustments based on service requirements.

1.3

Brief overview of services


Point to Point data services using GFP/VCAT entities shall be one of the important applications of the equipment architecture; wherein the memberchannels forming a VCAT Group (VCG) shall be dynamically configured @VCn-Xv, based on requirements. Packet data from one or more users shall also be multiplexed on to a single VCAT (VCG) channel, as required, utilising a centralised layer-2 aggregation (or layer-2 aggregation on Ethernet IO cards) in the system, for greater network efficiency. Point to point, Point to multi-point and Multi-point to multi-point services with EIR, CIR, {EIR+CIR} with configurable
-9-

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 10 -

burst duration shall be supported as per Metro Ethernet Forum (MEF) and ITU-T Rec. 8010, G.8011, G.8011.x series standards. 1.3.1 The equipment shall facilitate the delivery of the following services:

Fixed-rate Ethernet Private Line (EPL) Services Variable Rate (Burstable) Ethernet Virtual Private Line (EVPL) Services Layer-2 Ethernet Transparent LAN Service (TLS) commonly called (E-LAN) Services TDM Private Line Services Storage Area Networking (SAN) services.

The system shall provide OAM capability for various data services in accordance with ITU-T Recs. G.8010, G.8011, and G.8011.x series (for EPL, EVPL, EVPLAN etc.) and relevant MEF standards.

1.4

The equipment shall effectively combine LAN and WAN technologies in a flexible, scalable, and cost-optimised solution. It is expected that architecture shall address both Access and Metro Transport applications, enabling service providers to cost-effectively deliver traditional & emerging data and TDM services over a common Metro Ethernet Network (MEN) to both enterprises and residential customers. It is envisioned that the equipment shall combine key features outlined in various international standards to maximize bandwidth efficiency for transporting data over a Metro Ethernet Network. These standards include IEEE 802.1 and 802.3 series, ITU-T VCAT, GFP & LCAS as per ITU-T Recs. G.707, G.7041 & G.7042 respectively, Ethernet-Line/LAN service attributes and QoS requirements as per ITU-T Recs. G.8010, G.8011, G.8011.x series as well as per relevant MEF service standards.

1.5

At functional level, the STM-64 equipment shall broadly consist of the following sub-systems:

SDH VC-4/VC-3/VC-12 cross-connect system Layer-2 Ethernet MAC bridging & aggregation sub-system (on Ethernet IO cards or a central Ethernet MAC switch) Traffic ports (SDH, PDH, SAN & Ethernet etc.) Clock reference sub-system Traffic control & management sub-system Local SOH & POH termination for auxiliary channels & OH access sub-system Engineering Order-wire sub-system Power-supply sub-system etc.

- 10 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 11 -

The traffic/line ports - STM-64/16/4/1, 45/34/2 Mbps, SAN (FICON, ESCON, FC, DVB-ASI etc.) & Ethernet (Fast Ethernet & Gigabit Ethernet) interfaces, shall be flexibly equipped upto 100% capacity of the equipment. The purchaser may convey specific requirements for interfaces. But system shall be loaded with 100% capacity for testing. An illustration for interface loading is given in clause 8.0 in PART II of the GR for test purposes.

1.6

The equipment shall be configurable either as an ADM or as two Terminal Multiplexers (TMs) with software configurations only. The granularity of the cross-connection shall be at VC-12, VC-3 and VC-4 in single-stage and the size of cross-connect shall be as specified in the subsequent clauses of the document.

1.7

STM-64 Synchronous Multiplexer shall be an SDH based multiplexing equipment, supporting the set of specifications for Synchronous Digital Hierarchy as per ITUT Rec. G.707 (2003 version), constituting a Network Element. The equipment shall have the Network Node Interface (NNI) compliant to ITU-T Rec. G.707. The Network Element shall meet various atomic and compound functions of the multiplexing equipment as specified in ITU-T Rec. G.783, with extensive management control capabilities as specified in ITU-T Rec. G.784.

1.8

The equipment shall provide optical line interfaces at 9953.280Mb/s with standard optical interfaces as per ITU-T Rec. G.691 as detailed later. The architecture of the equipment shall be as per ITU-T Rec. G.803 and the generic functions of equipment shall be as per ITU-T Rec. G.805. On the tributary-side, the Network Element shall provide access to the constituent electrical signals through 2Mb/s, 34Mbps/DS3 (auto-sensed or configured) and 155.520Mb/s electrical interfaces (STM-1e) as per ITU-T Rec. G.703, as well as standard optical interfaces at STM-1, STM-4 and STM-16 bit-rates as per ITU-T Rec. G.957. The purchaser shall communicate exact application-code requirements for STM-N line and tributary interfaces.

1.9

The equipment shall provide TCM functionality at VC-4 paths (softwareconfigured for TCM monitoring) using N1 byte of Higher Order Path-Overhead, in accordance with ITU-T Rec. G.707.

1.10

The equipment shall also support Ethernet over SDH (EoS) transport capability at Fast Ethernet interfaces - 10/100BaseT & 100BaseFX@1310nm, optical GigE interfaces at - 1000BaseSX multi-mode (optional to purchasers requirements), 1000BaseLX @1310nm and 1000BaseLH @1310nm using ITU-T G.7041 specified GFP encapsulation. The equipment shall support both GFP variants i.e., GFP-F &

- 11 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 12 -

GFP-T, as per ITU-T Rec. G.7041. GFP-Framed mode shall be supported for Ethernet clients and GFP-Transparent (GFP-T) mode shall be supported for blockcode oriented SAN payloads i.e., FICON, ESCON, FC, DVB-ASI etc. GFP-T is recommended to be provided through a common-card along with GFP-F. However, standalone SAN IO cards for GFP-T shall also be permitted. In case of a common-card, for both GFP modes, the selection of particular GFP mode shall be either auto-sensed or through LCT & EMS configuration.

1.11

In case of a common-card, for both GFP modes, the GFP-F and GFP-T configuration shall be provided per client port basis.

1.12

The equipment shall provide layer-2 Ethernet bridging and aggregation functionality as per IEEE 802.1D, with 802.1P priority and 802.1Q VLAN-ID support per Ethernet user-port. The exact details for VLAN administration are provided in Appendix II to the GR. The Layer-2 aggregation shall support Rapid Spanning Tree Protocol (RSTP) as per IEEE 802.1s standard. The detailed technical specifications for Ethernet switch are provided later in the GR. The bandwidth granularity for Ethernet ports shall be 64Kb/s for Fast Ethernet and 1Mb/s for GigE ports. Further, it is envisaged that the equipment shall support Link Capacity Adjustment Scheme (LCAS) for VCAT groups as per ITU-T Rec. G.7042.

1.13

Virtual concatenation in the form of VC12-Xv and VC4-Xv as per ITU-T Rec. G.707 shall be provided in the equipment. VC3 based VCGs shall be optional to purchasers requirements. Contiguous concatenated payloads at VC4-4c, VC416c, and VC4-64c (as applicable) for all STM-N ports irrespective of whether it is tributary port or a line port, as per ITU-T Rec. G.707 shall also be supported for termination as well as for cross-connection across the equipment.

1.14

The VCG (VCAT) channels shall be universal i.e., any VCG shall be composed of VCns across any combination of STM-N interfaces in a non-blocking manner. Also the VCGs as well as slots in the chassis shall be independent of service provisioning i.e., there shall be no demarcation based on VCGs for Fast Ethernet, GigE, SAN interfaces etc.

1.15

In order to support the specified Ethernet requirements, there shall be adequate no. of VCGs in the system supporting GFP-F and GFP-T encapsulation.

1.16

The system shall be engineered to support at least up to 32 Fast Ethernet ports in TM mode and up to 64 ports for ADM mode. It is recommended that each IO card for Fast Ethernet supports a minimum of 8 Ethernet ports @10/100BaseT or
- 12 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 13 -

100BaseFX. The system shall also provide integrated layer-2 switching & aggregation, the requirements and specifications of which are given in clause 6.3 and sub-clauses thereof, in PART II of the GR.

1.17

In Ring topology, the equipment shall support both Multiplex Section Shared Protection Ring (MS-SPRing) at STM-64 & STM-16 ports/interfaces as well as SNC/N protection mechanisms at STM-1 & STM-4 ports/interfaces configured per VC12, VC3, VC4 through EMS/LCT, as specified in the ITU-T Rec. G.841. The equipment shall provide protection to the members of VCG also. The protection by default for members of a VCG shall be ENABLED until configured otherwise.

1.18

The STM-1, STM-4 and STM-16 tributary ports in STM-64 ADM shall either be used as linear tributary interfaces uplinked through STM-64 line interfaces as well as shall be utilised to terminate STM-1/STM-4/STM-16 rings. It shall be possible to add/drop tributaries, fully or partially, pertaining to these STM-1/4/16 tributary rings across STM-64 aggregate ring terminated on the ADM, in a non-blocking manner, subject to matrix capacity. Also, it shall be possible to cross-connect the tributaries of these STM-1/STM-4/STM-16 tributary-rings and STM-64 aggregate ring to any of the AU/TU in the central cross-connect of M-ADM/ADM for further transmission. The STM-1, STM-4 and STM-16 tributary-rings, stated here-in-above, shall also support protection mechanisms as specified in their respective TEC product-GRs.

1.19

In case, it is not possible to equip the equipment interfaces as per clause 8.0 in PART II of the GR, in a single main-chassis; the use of only a single expansionchassis shall be permitted. There shall be neither cross-connections performed in the expansion-chassis nor any control-card housed therein. In such cases, where the expansion-chassis is used, redundant connectivity between main & expansion chassis shall be provided. It is recommended than such redundant connectivity is provided through system backplane.

1.20

In case, an expansion-shelf is used, the cross-connection of tributaries as residing in the expansion-chassis shall also be made using central cross-connect in the main-chassis. No subtended cross-connect, at expansion-chassis level, shall be permitted. There shall be only one central cross-connect in the system providing single-stage cross-connection, as specified in clause no. 4.7 in PART II of the GR. Further, the system shall not provide any blockage as regards cross-connection across any STM-N line to tributary interfaces (and vice-versa) and also tributary to tributary interfaces. Also, the system shall provide VCG (VCAT) configuration

- 13 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 14 -

comprising of any VCn in the system spanning across any STM-N line interface and tributary slot in the system.

1.21

The equipment shall support various types of SDH cross-connections, viz. - point to point unidirectional and point to point bi-directional as well as point to multipoint unidirectional and broadcast connections.

1.22

Provision shall exist to loop-back input digital signals at various higher or equivalent hierarchical stages of SDH multiplex hierarchy through the equipment. There shall also be provision for local and remote MAC layer loopbacks.

1.23

The equipment shall have provision for synchronization with the timing-signal extracted from SDH aggregate signals i.e., STM-N signals terminating at the equipment, with minimum three user-defined priorities exercised through LCT/EMS. The equipment shall also have a provision to be synchronized with external 2MHz signal as well as 2048 Kb/s signal per ITU-T Rec. G.703. Also, the equipment shall provide at least two external (one 2Mbps and the other as 2MHz) timing output ports with accuracy traceable to the system synchronisation clock.

1.24 1.25

The EMS requirements for the system have been detailed in the Appendix-I. In Add/Drop configuration, the equipment shall provide "Through payload crossconnect" capability, "Local cross-connect" capability", Drop and Continue" as well as "Broadcast" capability.

1.26

The equipment is envisaged to be used mainly for metro applications, supporting ITU-T G.691 shorthaul applications @1550nm window. In order to achieve the specified span-coverage for shorthaul applications on ITU-T Rec. G.652 and G.655 fibre, the use of Dispersion Compensation and Accommodation techniques shall be permitted, if necessary, as specified in ITU-T Rec. G.691.

2.0
2.1

Reference Documents
Whatever technical specifications that have not been not been specifically stated in this document, shall deem to be as per relevant, latest ITU-T specifications.

2.2

Some of relevant specifications are given in Applicable Reference Documents in the beginning of the GR.

2.3

All reference to TEC GRs implies for their latest issues.

- 14 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 15 -

3.0
3.1 3.2

Engineering requirements
The equipment shall be fully solid-state and adopt state-of-the-art technology. The equipment shall be compact and composite in construction and shall be light-weight. The actual dimensions and weight of the equipment shall be furnished by the manufacturers.

3.3

All connectors shall be reliable and of standard type to ensure failure-free operation over long periods under specified environmental conditions. All components shall be CACT approved.

3.4

All connectors and cables used shall be of low-loss type and suitably shielded. The type of connectors used at the application interfaces & the user- interfaces shall be of wire-wrapping type or as per any other international industry standard. No soldering shall be allowed for the connectors.

3.5

The equipment shall be housed in standard 19" or ETSI standard rack and shall provide front access.

3.6

The equipment shall provide natural cooling arrangement which shall not involve any forced cooling by using fans etc., either inside or outside the equipment. In case, the natural cooling arrangement is not sufficient, the manufacturer may use fans for cooling purposes provided:

Fan redundancy in hot-standby mode is provided. The fan failure is reported through LCT/EMS. Multiple fans are there in one tray with (N:1) redundancy. Fans are located at convenient place in the equipment not disturbing the internal equipment layout. Fans are DC operated. MTBF is better than 80,000 hours. Inclusion of fans for cooling purposes does not deteriorate the MTBF values of the equipment.

3.7

The supervisory indications, built-in test equipment (BITE), and other control/ switches shall be provided at convenient locations on the bay preferably at a height of around 1500mm for ease of maintenance.

3.8

The plug-in units shall be hot-swappable as to allow their removal/ insertion while the equipment is in energized condition.

3.9

The mechanical design and construction of each card/ unit shall be inherently robust and rigid under all conditions of operation, adjustment, replacement,

- 15 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 16 -

storage & transport and shall conform to para-12 of BSNL-QA document no.: QM 333 (issue-2:1998) - "Specifications for environmental testing of electronic equipment for transmission and switching use". The equipment shall comply with B2 category for environmental conditions including vibration test. 3.10 Each sub-assembly shall be clearly marked with schematic references to show its function, so as to be easily identifiable from the layout diagram in the handbook. 3.11 Each terminal block and individual tags shall be numbered suitably with clear identifying code and shall correspond to the associated wiring drawings. 3.12 All controls, switches & indicators etc., shall be clearly marked to show their circuit designation and functions.

4.0
4.1 4.2

Operational Requirements
The equipment shall be designed for continuous operation. The equipment shall perform satisfactorily without any degradation up to an altitude of 3000 meters above mean sea level. manufacturer shall be acceptable. A test certificate from the

4.3

The equipment shall work without any degradation in saline atmosphere near coastal areas and shall be protected against corrosion. A test certificate from the manufacturer shall be acceptable.

4.4 4.5

Visual indication to show power ON/OFF status shall be provided. Wherever visual indications are provided, green colour for healthy and red colour for unhealthy conditions shall be used. Some other colour shall be used for non-urgent alarms.

5.0
5.1

Quality Requirements
The manufacturer shall furnish the MTBF/MTTR values for the equipment. The calculations shall be based on the guidelines in either BSNL-QA document no.: QM-115 (January 1997) - "Reliability Methods and Predictions" or as per any other international standard.

5.2

The equipment shall be manufactured in accordance with international quality standards ISO-9001, ISO-9002 or ISO-9001:2000 for which the manufacturer shall be duly accredited. A quality plan describing the quality assurance system followed by the manufacturer shall be required to be submitted.

- 16 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 17 -

5.3

The equipment shall conform to the environmental requirements as specified in BSNL-QA document no.: QM-333 (latest issue): "Specification for environmental testing of electronic equipment for transmission and switching use". The applicable tests shall be taken for environmental category B2 including vibration test.

6.0
6.1

Maintenance requirements
Maintenance philosophy shall be to replace faulty units/subsystems after quick on-line analysis through monitoring sockets, alarm indications and Built-in Test Equipment. The actual repair shall be undertaken at centralized repair centres. The corrective measures at the site shall involve replacement of faulty units/sub-systems.

6.2 6.3

The equipment shall provide easy access for servicing and maintenance. Extension of degraded paths to the test-access points for diagnostic work, after traffic is switched over to the healthy path, shall be provided.

6.4

Suitable visual/audio alarms shall be provided for identification of faults in the system as well as in faulty units. Suitable potential free contacts (preferably) or any other suitable method, shall be provided for extension of summary alarms.

6.5

As and when bugs are found/determined in the software, the manufacturer shall provide patches/firmware replacement, if involved, free of cost for three years. Modified documentation, wherever applicable, shall also be supplied free of cost or as mutually agreed between the vendor and the purchaser.

6.6 6.7

Ratings and types of fuses used shall be indicated by the supplier. The manufacturer/supplier shall furnish the list of recommended spares for three years maintenance.

6.8 6.9

The supplier shall have maintenance/repair facility in India. Supplier shall guarantee the spares so long as the equipment is in service, at least for 10 years from the date of supply. The purchaser shall like to stock spares as and when the supplier decides to close-down the production of the offered equipment. In such an event, supplier shall give a two years notice to the purchaser so as to stock the spares.

7.0

Power Supply
The equipment shall be powered by the station power-plant and shall meet the

- 17 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 18 -

following requirements: (a) Nominal power supply is -48V DC with a variation in the range -40V to -60V. The equipment shall operate in this range without any degradation in performance. (b) (c) (d) (e) The equipment shall be adequately protected against voltage variation beyond the range specified in sub-clause (a) and also against reverse input polarity. The power consumption shall be minimal. The actual power-consumption shall be furnished by the manufacturer. The derived DC voltages in the equipment shall have adequate protection against over-voltage, short-circuit and overload. The equipment shall have a provision for redundancy of power supply cards.

8.0
8.1

Accessories
The supplier shall provide one complete set of: a. All necessary interfaces, connectors, connecting cables and accessories required for satisfactory and convenient operation of the equipment. Types of connectors, adapters to be used and accessories of approved quality shall be clearly indicated in the operating manuals which shall be in conformity with the detailed list in the GR. b. Software and the arrangement to load the software at site.

Note: Additional sets shall be ordered optionally. 8.2 Special tools, extender boards, extender cables and accessories as essential for installation, operation and maintenance of the equipment shall be clearly indicated and supplied along with the equipment. 8.3 Special tools, extender boards, extender cables and accessories as essential for repair of the equipment shall be clearly indicated and supplied in case the same are ordered.

9.0

Documentation
Technical literature in English language with complete layout, detailed blockschematics and circuit-diagrams of various assemblies shall be supplied. The repair philosophy of the equipment shall be specified by the manufacturer. All aspects of installation, operation and maintenance shall be covered in the manuals. The manuals shall include the following: i) Installation, Operation and Maintenance Manual: a) Safety measures to be observed in handling the equipment.
- 18 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 19 -

b) Precautions for installation, operation and maintenance. c) Test jigs & fixtures required and procedures for routine maintenance, preventive maintenance, troubleshooting and sub-assembly replacement. d) Illustration of internal and external mechanical parts. ii) Repair Manual (to be supplied when ordered): a) List of replaceable parts used including their sources and the approving authority shall be provided. b) Detailed ordering information for all the replaceable parts shall be listed in the manual to facilitate re-ordering of spares. c) Procedure for trouble-shooting and sub-assembly replacement shall also be provided. Test fixture and accessories required for repair shall also be indicated. Systematic trouble-shooting chart (fault tree) shall be given for the probable faults with their remedial actions.

10.0
10.1 10.2

Protection requirements The equipment shall have a terminal for grounding the rack. Protection against short-circuit/open-circuit in the accessible points shall be provided.

10.3

All switches/controls on front panel shall have suitable safeguards against accidental operation.

10.4

The equipment shall be adequately safeguarded to prevent entry of dust, insects and lizards.

11.0

Optical Safety Requirements The equipment shall meet optical safety requirements as per ITU-T Rec. G.664 and IEC-60825-1 (latest edition). The equipment shall have visual warning and controls ensuring danger-free operation. Automatic Power Reduction (APR) or Automatic Laser Shut-Down (ALSD) shall be provided at all optical line & user/traffic interfaces as per ITU-T Rec. G.664.

12.0

Optical Access Port The optical access ports shall be so designed as to protect themselves against entry of dust when they are not occupied by an external fiber-optic

- 19 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 20 -

connection. The optical access port shall be located appropriately as to be easy to operate. The optical access port shall be easy to clean by the user. 13.0 Operating Personnel Safety Requirements The operating personnel shall be protected against shock hazards as per: IS:8437 {1993}: Guide on the effects of current passing through the human body [equivalent to IEC publication 479-1 {1984}]. The equipment shall also conform to: IS:13252 {1992}: Safety of information technology equipment including electrical business equipment[equivalent to IEC publication 950 {1986}]. The equipment shall follow proper construction practice to minimize unintended radiation due to leakage from any gap or monitoring points. All unused ports and monitoring points shall be terminated. The power-flux density shall not exceed 1mW/cm 2 at a distance of 2.5 cms. 14.0 Electromagnetic Compatibility (EMC) The equipment shall conform to the EMC requirements as per the following standards and limits indicated therein. A test certificate and test report shall be furnished for: a) Conducted and radiated emissions: To comply with Class A or B [to be specified in the GR as per the product requirement] of CISPR 22 {2003} - "Limits and methods of measurement of radio disturbance characteristics of Information Technology Equipments"; b) Electrostatic discharge: To comply with IEC 61000-4-2 {2001} - "Testing and measurement techniques of Electrostatic discharge immunity test" under following test levels: Contact discharge level 2 { 4 KV}; Air discharge level 3 { 8 KV}; c) Fast-transients common-mode (burst): To comply with IEC 61000-4-4 {1995 with Amendment 1 (2000) and Amendment 2 (2001)} - "Testing and measurement techniques of electrical fast transients/ burst immunity test" under Level 2 {1 KV for DC power lines; 1 KV for signal control lines}; d) Immunity: IEC 61000-4-3{2002} Radiated RF Electromagnetic Field Immunity test under test level 2 (test field strength 3 V/m) for general purposes in
- 20 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 21 -

frequency range 80 MHz to 1000 MHz and under test level 3 (10 V/m) for protection against digital radio telephones in frequency ranges 800 MHz to 960 MHz and 1.4 GHz to 2.0 GHz. e) Surges line to earth coupling and line to line coupling: To comply with IEC 61000-4-5{2001}Test & Measurement techniques for Surge immunity tests" under test levels of 0.5 KV for line to line coupling and 1KV for line to earth coupling; f) Radio frequency common-mode: To comply with IEC 61000-4-

6{2001}"Immunity to conducted disturbances, induced by radio frequency fields" under the test level 2 {3 Vrms} clamp-injection method for DC lines and Signal Control lines. Note (i): Class B: Classification of the equipment: Class B is a category of apparatus which satisfies the class B disturbance limits. Class B is intended primarily for use in the domestic environment and may include: Equipment with no fixed place of use; for example, portable equipment powered by built in batteries; Telecommunication terminal equipment powered by the telecommunication network; Personal computers and auxiliary connected equipment. Note (ii): The domestic environment is an environment where the use of broadcast radio and television receivers may be expected within a distance of 10 m of the apparatus connected. Class A: Class A is a category of all other equipment, which satisfies the class A limits but not the class B limits. Note (iii): For tests for checking compliance to above EMC requirements, the method of measurements shall be in accordance with TEC standard No.:SD/EMI02/02.SEP.2001 and the references mentioned therein.] Note (iv): A test certificate from autonomous & accredited lab shall be acceptable on this account.

- 21 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 22 -

Part II Technical Requirements

- 22 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 23 -

PART-II [TECHNICAL REQUIREMENTS]

1.0 1.1

Functional requirements
It shall be possible to configure the ADM equipment as two back to back TMs by extracting/disabling the requisite hardware, and software settings. The equipment shall not extend any alarm, upon disabling/extracting the hardware.

1.2

The hot-swapping of a card/unit shall not affect working of any other tributaries. Hot-swapping capability shall be provided for all cards/units including powersupplies. No EMS notification or system setting shall be required for extraction or insertion of any unit/card.

1.3

It shall be possible to configure the network as unprotected and fully-protected in case of MS-SPRing protection. In case of SNC protection, it shall be possible to configure the network as fully-protected, partially-protected or unprotected. In case of MS-SPRing protection, it shall be possible to transport extra-traffic over protection-channels i.e., over protection VC4s during normal operation of a ring as specified in ITU-T Rec. G.841. Upon failure, the working traffic shall switchover to these protection channels.

1.4

The equipment is envisaged to comply with S 64.2a or S 64.2b optical interfaces @1550nm window as specified in ITU-T Rec. G.691. For test purposes, optical tributary interfaces @ STM-1o and STM-4o shall be as per ITU-T Rec. G.957 shorthaul application (S 1.1 and S 4.1 respectively at 1310nm) while the purchaser may ask for any other application-code. The exact requirements for optical interfaces for tributaries and aggregate shall be specified by the purchaser.

1.5

Also, the equipment shall support optional colour wavelength at STM-16 and STM64 aggregate levels as specified in ITU-T Rec. G.694.1. The manufacturer shall supply any of the wavelengths asked by the purchaser.

1.5.1

Ethernet interfaces: Power-budget specification The reach and power budget requirements for this document for various Ethernet interfaces shall be100BaseFX @1310nm 1000BaseSX1 (50 multi-mode) interface
Link power budget (multi-mode) Operating distance (nominal) Channel insertion loss 7.5dB 550m 3.56dB 8dB power budget on G.652 fibre.

- 23 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 24 -

Link power penalties Unallocated margin in link power budget 1

3.57dB 0.37dB

Link penalties are used to calculate link budget and distances and is not intended to be tested. A wavelength 830nm is used to evaluate channel insertion loss, link power penalties, and unallocated margin. Attenuation for 50 multi-mode fibre at 830nm is taken as 3.5dB/km and 1.5dB/km at 1310nm. * 1000BaseSX interface is optional to purchasers requirements. The interface shall be supplied with multi-mode to single-mode adaptor as an integral part of the offer.

1000BaseLX2 (10 single-mode @1310nm) interface


Link power budget Operating distance (nominal) Channel insertion loss Link power penalties Unallocated margin in link power budget 2 8.0dB 5000m 4.57dB 3.27dB 0.16dB

Link penalties are used to calculate link budget and distances and is not intended to be tested. A wavelength 1270nm is used to evaluate channel insertion loss, link power penalties, and unallocated margin. Attenuation for 10 single-mode fibre at 1300nm window is taken as 0.5dB/km.

1000BaseLH3 (10 single-mode @1310nm) interface


Link power budget Operating distance (nominal) Channel insertion loss Link power penalties Unallocated margin in link power budget 3 10.5dB 10,000m 7.8dB 2.5dB 0.2dB

Link penalties are used to calculate link budget and distances and is not intended to be tested. A wavelength 1270nm is used to evaluate channel insertion loss, link power penalties, and unallocated margin. Attenuation for 10 single-mode fibre at 1300nm window is taken as 0.5dB/km.

1.6

Two bytes viz. E1 or E2 are assigned for EOW applications. Either of the two bytes or both shall be used for the order-wire for the maintenance of the equipment, supporting Multiplexing to Multiplexing stations calling with full-duplex selectivecalling facilities. VoIP based implementation for EOW shall be permitted subject to1. Speech quality shall be equivalent to ITU-T Rec. G.712. 2. End to end packetized voice characteristics are with in ITU-T Rec. G.114 prescribed limits. 3. Manufacturer is able to arrange the test methodology and test procedure at his/her arrangements.

1.7

The order-wire shall be restored along with payload in case of system switchingover from normal to protection-channel and vice-versa. No disconnection of call in selective-calling mode shall take place in event of protection switching.

1.8

The equipment shall have the capability of providing the Timing Signal quality information as per ITU-T Rec. G.707 using S1 byte.

- 24 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 25 -

1.9

The power-supply failure/ Work Station/ Network Server break-down/ bugs in the software shall not affect the current tributary-connection map. The removal/replacement of any unit shall also not affect the existing connection map. No reconfiguration is called for against this action.

1.10

Differential Delay for VCAT Implementation Differential delay in reference to VCAT implementation refers to the maximum delay in arrival times of different members of a VCAT group. The manufacturer shall ensure that the system is capable to compensate for all values of differential delay from 125s right upto 30ms, as a continuous range. The systems capable to compensate for less than 30ms differential delay, shall be liable for rejection. Similarly, on the higher-side, the systems capable to compensate for >50ms differential delay, shall also be liable for rejection. The range from 30-50ms has been kept as a guard-band for implementation tolerance.
Desired continuous range for compensation Guard-band for design tolerance Rejection range

125s

30ms

50ms

Acceptance range
TEC confidential

Figure 1: Illustration for differential-delay compensation limits

The same limit shall apply to all VCs i.e.- VC12, VC3 & VC4.

1.11

The manufacturer shall ensure MS-SPRing interworking with equipment of other vendors.

1.12

There shall be no single point-of-failure in the system. For that objective, in ADM mode, the East & West-side TX/RX STM-N interfaces for STM-64 aggregate as well as STM-1/4/16 tributary rings shall be accommodated on two separate cards.

1.13

The provision for 100BaseFX Ethernet interface shall preferably be made through IO cards in the system; however the use of separate media-converter for conversion of electrical Fast Ethernet interface to 100BaseFX (and vice-versa) shall also be acceptable. There shall be adequate arrangements provided for these media-converters to be mounted in standard racks. The system engineering of the

- 25 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 26 -

equipment shall be well-planned to route the optical patch-cords from the sideways of the equipment to avoid jumbling of patch-cords.

1.14

Network Applications of STM-64 multiplexer The main applications of STM-64 equipment in a metro network shall be the network-nodes where a lot of wide-band traffic from multiple lower-speed tributaries needs to be consolidated, groomed and distributed towards high-speed core network & vice-versa. It shall also offer data interfaces for terminating and aggregating layer-2 traffic. The system shall also be used for Storage Area Networking applications. In Terminal Multiplexer mode, STM-64 equipment may be used to consolidate metro traffic on STM-64 interface constituting one channel of DWDM longhaul network. The inclusion of STM-64 equipment at the Central Office shall facilitate replacement of multiple ring-wise ADMs at Central Office for flexible ring-interconnection in a non-blocking manner facilitating metro traffic aggregation. It shall be possible to configure the equipment in various topologies i.e., mesh connectivity, star connectivity as well as other network topologies. The STM-64 equipment must support the following range of Network Element applications: 1. Linear topologies with add/drop functions (chains) & hubbing operation. 2. Arbitrary mesh topology with a robust mesh restoration. 3. Ring topologies with support for termination of multiple rings on all optical line/tributary ports. The equipment shall be configured as a multi-line TM, as an ADM as well as a stand-alone cross-connect for various network applications.

1.15

Equipment Redundancy The equipment shall provide complete redundancy for 1. Control/Processor If the Control/Processor unit failure does not affect the working traffic, no redundancy of Control/Processor unit shall be required. However, if the Control/Processor unit failure does result in traffic failure, then (1+1) hot-standby mode redundancy of Control/Processor shall be provided in the equipment. Immediate upon insertion of a healthy card, the system shall revert to its pre-failure NMS/EMS configuration.

- 26 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 27 -

There shall be support for dual homing for EMS connectivity for no loss of EMS connectivity, through two Gateway NEs (GNEs) on a ring. Both GNEs shall have control- card equipped. In case of total loss of EMS connectivity to the system/network, the system design shall provide local storage of all performance & fault data, as specified in Appendix I to GR, for all connections pertaining to all NEs, in the sub-network. Such connectivity loss might happen due to control-card failure at both GNEs and/or failure of DCN link to EMS. In-built intelligence shall be there in EMS for selection of appropriate GNE at distant end of a DCN link upon failure of control card at one of the GNEs, for EMS connectivity. Note: The performance data as envisaged above for SDH connections shall also be ensured for Ethernet clients. 2. Switch/Matrix There shall be provision for a parallel hot-standby matrix unit as per details as in clause 4.7 (for SDH connect) to take-over traffic during failure of the working card. In case of centralised MAC SW, there shall be a backup MAC SW. For distributed MAC switching on IO cards, it is recommended that there shall be a combined backup IO card for both Fast and Gigabit Ethernet interfaces with capacity as detailed later in the GR. The local Ethernet traffic after PHY termination in IO card shall have autonomous path availability to the MAC fabric of this backup IO card through backplane. The user Ethernet traffic shall be switched to this alternate path if MAC fabric fails in an IO card. The switching over time from working switch matrix to standby matrix (at SDH & MAC layers) shall be completed within 50 ms. 3. Power Supply If the power-supply is provided through a centralized power-supply unit at chassislevel, a hot-standby power-supply shall be provided at chassis-level, to ensure smooth working of the equipment during failures. Further, there shall be provision for dual-feed arrangement to the chassis powersupply, such that in case of failure of one feed, the system shall be able to function in a healthy manner without traffic interruption. 4. There has to be complete redundancy for Timing Circuitry against failures.
* The changeover for all redundancy actions shall be completed with in 50ms.

- 27 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 28 -

1.16
1.16.1

Construction Practice
Expansion chassis Solution shall be supplied as a single-chassis solution. Only one expansion-chassis shall be permitted if the whole capacity as per clause 8.0 in PART II of the GR is not accommodated in a single main-chassis. The expansion-chassis shall contain only IO cards. There shall be single-stage (direct) and non-blocking access/visibility of the central cross-connect to all IO cards irrespective of whether an IO card is in main or expansion-chassis. There shall be no control-card and cross-connect card equipped in the expansion-chassis. The expansion-chassis shall provide dualredundant connectivity to the main-chassis.

1.16.2

Cross-connect architecture There shall be single-stage cross-connection in the equipment. For that, there shall be no cross-connections performed in the expansion-chassis. The expansionchassis, if used, shall only serve as IO extension-cage. There shall be single-stage 4/3/1 cross-connection for all the IO cards in a non-blocking manner.

1.16.3

Universal-slot architecture It is recommended that all slot positions except control-card, matrix, STM-N optical and power supply slots shall be universal. Any interface unit shall be housed in any slot.

2.0

Transport media
The equipment in the longhaul application shall use Standard Single-Mode Fibre cable as per TEC GR Nos. 1. GR/OFC-01/ 04.SEP.2003 (with all amendments) on Metal Free Optical Fibre Cable 2. GR/OFC-02/03 SEP.2003 (with amendments) on Armoured Optical Fibre Cable 3. GR/OFC-05/01.JUL.2000 (with amendments) on Metal-Free Optical Fibre Ribbon Cable. 4. GR/OFC-06/01.JAN.2001 (with amendments) on Armoured Optical Fibre Ribbon Cable. 5. GR/OFC-08/01.JUL.2003 (with amendments) on Metal-Free Optical Fibre NZ-DSF Cable.

3.0

Performance Requirements
The equipment shall be tested for error performance as follows: a) In laboratory: BER performance over simulated hop shall be tested better than 1x10 -10 for 48 hours on each channel at reference receive-level (nominal level). Also IETF RFC 2544 compliance shall be tested for end-to-end Ethernet service.

- 28 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 29 -

b) In field: BER performance for 48 hours shall be established to conform to ITUT Recs. G.826 & G.828.

4.0 4.1

Network Requirements
Application topologies The equipment is envisaged to work on shorthaul application code, S 64.2a or S 64.2b, as per ITU-T Rec. G.691.

4.1.1

Classifications and application codes The STM-64 Synchronous Multiplexer shall support shorthaul S 64.2a or S 64.2b optical line interface for G.652 fibre and S 64.5a or S 64.5b optical line interface for G.655 fibre, as per ITU-T Rec. G.691. The targeted distances are defined in Table-1 are based upon attenuation of 11dB/40 kms. at 1550nm worse than 10 -12. The distance figures given in the Table-1 are between the optical Mux and Demux without In-Line Amplifiers. System may implement FEC as per ITU-T Rec. G.707 or G.709 to achieve application code requirements.
Table-1 Fibre Type Application Code Target distance (km) G.652 S-64.2a 40 G.652 S-64.2b 40 G.655 S-64.5a 40 G.655 S-64.2b 40

as per ITU-T G.691. These limits are the worst-case

figures at the end of life and are based upon the design objective of a BER not

4.2

Network topologies It shall be possible to configure the equipment to implement various network topologies as detailed below1) Point to point/Linear-chain topology 2) Bus topology 3) Ring or Hub 4) Mesh topology. Two-fibre application i.e., one dedicated fibre for transmit-direction and one for receive-direction is envisaged for all network applications as above.

4.3

Equipment configuration The equipment shall support the following configurations1) Terminal Multiplexer
- 29 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 30 -

2) Add/Drop Multiplexer. 4.3.1 Ring termination capability The following ring inter-connection topologies shall be supported.

Single-Node Interconnected Rings Two-Node Overlapping Rings Two-Node Interconnected Rings

Single-Node Interconnected Rings This topology uses one node to connect two separate rings. The interconnecting node uses four optical ports (two for each ring). Each ring must use two ring-ports on two separate modules (east and west). Equipment shall support the following protection schemes in single-node interconnections-

Figure 2 Single-Node Interconnected Rings

SNCP ring <> SNCP ring. SNCP ring <> MS-SPRing.

Node-1

Two-Node Overlapping Rings This topology connects two rings using a single fiber between two optical modules. At each interconnecting node there are three optical ports: two east and a shared west. Each ring shares the bandwidth of the west port. Equipment shall support the following protection schemes in two-node overlapping ring interconnections: SNCP ring <> SNCP ring. SNCP ring <> MS-SPRing.
Figure 3- Two-node overlapping rings
Node-2

- 30 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 31 Node-1

Node-2

Figure 4: Two-node interconnected rings

Two-Node Interconnected Rings This topology uses four trunk ports in each node to connect two separate rings. The east and west port of each ring must be on two separate modules. Equipment shall support the following protection schemes in two-node ring interconnections: SNCP ring <> SNCP ring. SNCP ring <> MS-SPRing.

4.4
4.4.1

Resilience & Protection


Network Protection The equipment shall provide configurable SNC/N path-protection at VC12, 3 & 4 hierarchical levels, in accordance with ITU-T Rec. G.841 at all STM-1, 4, 16 & 64 traffic interfaces. All electrical STM-1, optical STM-1, STM-4, STM-16 & STM-64 traffic ports shall participate in any combination of SNCP schemes as per ITU-T Rec. G.841 configured by LCT/EMS. Traffic ports participating in the protection schemes shall belong to same or different modules. The STM-16 and STM-64 traffic ports/interfaces shall also participate in 2-fibre MS-SPRing protection as per ITU-T Rec. G.841. A multiple of MS-SPRings at STM-16 interface (with 16 STM-1 equivalent tributaries) shall be terminated on the equipment subject to matrix capacity constraints. Similarly, a multiple of SNC rings at STM-1, STM-4, STM-16 and STM-64 tributary ports shall be terminated by the equipment subject to matrix capacity. It shall be possible to provide SNC/N protection to all/selected tributaries (emanating from a node) or no protection may be provided, at all, to any of the tributaries. Similarly, there shall be provision for configuring selective/no protection to individual multiplex-sections in a ring (aggregate & tributary rings) as

- 31 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 32 -

well as to various VCns within a multiplex-section. Such protection configurations shall be possible through EMS/LCT. The details for the equipment ports to provide support for network protection mechanisms are: SDH Layer Linear MSP for STM-1, STM-4 and STM-16 interfaces 2-fibre MS-SPRing with configurable E-NUT capability for STM-16 and STM-64 interfaces AU4/AU3/TU3/TU12 (1+1) SNCP protection at STM-1, STM-4, STM-16 and STM-64 interfaces in accordance with ITU-T Rec. G.841 with Non-intrusive as well as optional Inherent monitoring. The following nesting (combination) of network protection switching shall be supported: Nesting of a linear (1+1) MSP with SNCP for any order of VC i.e., VC4, VC3 & VC12. Nesting of 2-fibre MS-SPRing with SNCP for any order of VC i.e., VC4, VC3 & VC12. The equipment shall support termination for a multiple of SDH rings. Ring interworking and/or dual-homing shall be supported via drop & continue functionality as described in clause no. 4.8.2 of the GR. The manufacturer shall ensure MS-SPRing protection interworking with other vendors equipment. MAC Layer In addition to SDH level protection; there shall also be configurable RSTP protection @IEEE 802.1s, offered to packet traffic at MAC layer. The layer-2 protection shall be configurable through LCT & EMS per Ethernet user-flow.

4.4.1.1

Multiplex Section Shared Protection Ring (MS-SPRing) The equipment shall support the MS-SPRing @STM-64 and STM-16 interfaces, applicable to the ring topology as defined in the ITU-T Rec. G.841 with two-fibre working. In MS-Shared Protection Rings, the working channels shall carry normal traffic while the protection channels shall be reserved for protection of this traffic. The traffic shall be transported bi-directionally. The granularity of

- 32 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 33 -

protection shall be VC4. The configurable E-NUT capability for running extra traffic on protection channels shall also be provisioned. The equipment shall support the facility of disabling/enabling the MS-SPRing feature for specific STM-N sections from the Network Manager of EMS.

4.4.1.2

Sub-Network Connection Protection Non- Intrusive (SNC-N) SNC-N scheme shall be provided at 1) VC-4 level 2) VC-3 level 3) VC-12 level. This protection is applicable for ring configuration using two fibres. The container generated from a PDH interface is mapped to form two virtual containers. Each of these two containers has the same data payload and is independently transmitted in both directions of transmission around the network. At the receiving end multiplexer, both the VCs are received and monitored and the VC with better performance is selected and de-mapped to the container level. As both the VCs are continuously monitored the switch can switch the de-mapping process to the second VC in the event of a signal failure or signal degradation of the selected VC. It shall be possible to configure the network as fully protected network, partially protected network and unprotected network via EMS. The purchaser may exercise option for SNC-I protection.

4.4.2

Equipment Protection The equipment shall support MSP [1+1] protection for all STM-N interfaces. It shall be at users discretion to ask for it or not. The inter-connection of an expansionchassis to main-chassis, if any, shall compulsorily provide [1+1] protected redundant connectivity. All common cards e.g., control/processor, switching-matrix [SDH], timing-source, power-supply etc., are envisaged as (1+1) hot-standby protected as per conditions laid-down in clause 1.15 in PART II of the GR.

4.4.3

Protection Switching Time for MS-SPRing In a ring (less than 1200 kms. in length) with no extra traffic and all nodes in the idle-state (i.e. no detected failures, no active automatic or external commands, and receiving only Idle K-bytes), the switch (ring and span) completion time for a failure on a single-span shall be less than 50ms. On rings under all other conditions,

- 33 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 34 -

the switch completion time might exceed 50ms marginally (the specific interval is under study) to allow time to remove extra-traffic, or to negotiate and accommodate coexisting APS requests. 4.4.4 Protection Switching Time for SNC The protection switching for LO-VCs and HO-VCs shall be completed within 50ms. Protection switch completion time excludes the detection time necessary to initiate the protection switch and the hold-off time.

4.5

System Restoration The equipment shall provide system restoration as follows:

It shall identify the failures in the connected route by monitoring SDH Overhead bytes. It is recommended that there shall be end to end SNC protection in a mesh network topology. The memory shall be non-volatile to avoid any loss of data in case of total system-failure. The restoration of the network shall be supported by the management system offered with the equipment. The cross-connection map shall acquire back its pre-failure condition after restoration of faults.

4.6

Traffic interfaces in M-ADM/ADM/TM configuration It shall be possible to configure system to support the following types of SDH, PDH, SAN and Ethernet payloads 1. 2. 3. 4. 5. 6. 7. 8. 9. STM-64o (as part of STM-64 MS-SPRing/SNC aggregate ring) STM-16o (as a point to point tributary or part of a STM-16 MS-SPRing/SNC ring) STM-4o (as a point to point tributary or part of a STM-4 SNC ring) STM-1o and STM-1e (as a point to point tributary or part of STM-1 SNC ring) 34.368Mbps/DS-3 (44.736 Mbps) [auto-sensed or configurable] 2048 Kbps PDH interface Ethernet interface 10/100BaseT Cat-5 UTP Ethernet interface 100BaseFX @1310nm single-mode interface. Ethernet interface 1000BaseSX multi-mode interface {optional}.

10. Ethernet interface 1000BaseLX @1310 nm single mode interface. 11. Ethernet interface 1000BaseLH @1310nm single-mode interface. 12. Fibre Connection (FICON) SAN interface 13. Enterprise Systems Connection (ESCON) SAN interface 14. Fibre Channel (FC) SAN interface 15. Digital Video Broadcasting - Asynchronous Serial Interface (DVB-ASI) interface.

- 34 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 35 -

Note 1: Subscript e stands for electrical interface and o stands for optical. Note 2: Use of 1310nm window shall be permitted at STM-1o, STM-4o & STM-16o tributary interfaces for shorthaul applications. The purchaser is to indicate exact application-code requirements for optical tributary interfaces.

4.7

Cross-Connect Capability The STM-64 Synchronous Multiplexer shall provide cross-connect capability with a granularity of VC-4, VC-3 and VC-12 bit rates. It shall be possible to provide dynamic cross-connectivity between any hierarchical VC to any other VC at same hierarchical-level across STM-64 aggregate ring as well as across terminating STM16 rings, STM-4 and STM-1 rings (terminated on tributary ports) in flexible and nonblocking manner. Similarly, there shall also be possible provisioning between tributary to tributary ports for all VC hierarchies, subject to capacity constraints. The lower-order (LO) VC-3 and VC-12 cross-connect granularity shall be implemented using an integrated approach i.e., using cross connections at VC-4, VC-3 and VC-12 in the same equipment in single-stage. Equipment implementation with two-stage cross-connection shall be liable for rejection. It shall be possible to switch any VC-12/VC-3/VC-4 from any physical port to any other VC-12/VC-3/VC-4 of any physical port irrespective of whether is tributary port or aggregate port. The granularity of switching shall be minimum VC-12. The equipment shall implement the cross-connect size asAs an ADM
256x256 VC-4 equivalents at VC-4 hierarchical level i.e., a total of 512 VC-4s :

HOVC.
128x128 VC-4 equivalent at VC-12 and VC-3 hierarchical level i.e., a total of 256

VC-4s, 256x3 VC-3s or 256x3x63 VC-12s : LOVC. Each port in the above description is assumed as unidirectional and hence shall be configured for any direction of transmission (TX or RX). The particular VC-4s granular up to VC-12 and VC-3 shall be dynamically configured out of all possible STM-Ns in the system including aggregate (for both East & West) as well as tributary ports through EMS. A total of 128 nos. bi-directional VC-4s, from West & East directions, shall be available for flexible termination physically in form of E1/E3/DS3s as well as Ethernet & SAN tributaries and/or a mix of them. The TUs, in the east port, the TUs in the west port in aggregate ring as well as the signals in the tributary ports shall be flexibly cross-connectable subject to

- 35 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 36 -

matrix capacity. This will facilitate rearrangement of TUs on the main STM-64 routes, thereby permitting efficient capacity utilisation. In addition, the equipment in ADM configuration shall support "Drop-and-Continue" or "Broadcast" capability, where the connection of one TU to a tributary interface will not restrict its continuation along the main STM-N route. The equipment shall also support local cross-connect capability between tributary interfaces without having any interconnection with STM-N signals. This capacity shall be subject to matrix capacity for such cross-connections at tributary level. This is intended for remote provisioning of leased -line services.

4.8

Type of connections on SDH path-layer


The equipment shall provide support for the following types of connections:

4.8.1

Bi-directional connection Bi-directional connections shall provide connectivity in both directions of flow of signals at VC12, VC3 and VC4 for point to point applications. This shall be used for normal two-way transmission of traffic.

4.8.2

Drop & Continue connection The equipment shall provide Drop & Continue mode of connection where the signals received from one port shall be dropped at a port and continued via a third port, as per requirement, for onward transmission. Such configuration shall be possible through management system control. This feature shall be provisioned @VC12, VC3 and VC4 levels. The drop and continue channels may also be aggregated using VCAT to form a drop & continue GFP-encapsulated point-to-multipoint VCAT packet transport.

4.8.3

Unidirectional Broadcast connection The unidirectional broadcast connection shall support point to multi-point transmission of the same signal. It shall be unidirectional. This type of connection shall be suitable for video transmission applications. This feature shall be provisioned @VC12, VC3 and VC4 levels. The equipment shall also support aggregation of one or more unidirectional broadcast connections using VCAT to form a Broadcast packet transport.

- 36 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 37 -

4.9

Loop-backs at SDH and MAC Layers The equipment shall be capable of providing local as well as remote userconfigurable (transparent as well as non-transparent) loop-backs at the interface ports, at the input of the matrix as well as at the output of the matrix. There shall be no limitations on the loop-backs and the loop-backs at AU-4, AU-3, TU-3, TU-12, VC-4, VC-3 & VC-12 levels shall be possible. It shall be possible to control/manage the loop-backs using local craft terminal and EMS of the system. There shall also be capability to provide loop at MAC layer for all Ethernet ports (both local and remote loop-backs). The equipment shall also be capable for necessary VLAN swapping for realizing a MAC layer loop for measurement purposes through the equipment.

5.0 5.1

System Requirements
Synchronisation The synchronisation of the system shall be done in accordance with ITU-T Rec. G.783. The synchronisation network shall be based on Primary Reference Clock. The internal and holdover-mode clock interfaces shall meet the timing requirements the option-1 of ITU-T Rec. G.813. The SDH Equipment Clock (slave clock) shall meet the requirements related to the SDH equipment as per ITU-T Rec. G.781 as well as Rec. G.813.

5.1.1

Synchronisation References The synchronisation references shall be in accordance with ITU-T Rec. G.783. The SDH equipment Terminal Multiplexers, Add/Drop Multiplexers shall have provision of deriving the timing references from the following types of inputs apart from its internal oscillator1. Incoming STM-64 line. 2. Incoming STM-16 signal. 3. Incoming STM-4 signal. 4. Incoming STM-1 signal 5. External clock at 2048 KHz as per ITU-T Rec. G.703. 6. External clock at 2048 Kb/s as per ITU-T Rec. G.703. It shall be possible for user to select minimum three timing-reference signals and their priority shall be set through management software. T equipment shall he generate Timing Marker and shall be able to transfer it to other nodes via S1 byte in the Section-Overhead.

- 37 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 38 -

In the event of selected reference-timing as mentioned above is lost, the SDH equipment shall switch-over to next priority reference timing within 300ms to 1800ms. It shall be possible to provide both manual and automatic-reversing timing-signal through software. The WTR period for automatic reversing shall be as per ITU-T Rec. G.781. 5.1.2 Frequency Accuracy The frequency accuracy of the internal oscillator of the SDH equipment in freerunning condition shall be 4.6 ppm (The test time shall be minimum 24 hours). 5.1.3 Hold-over mode accuracy The holdover mode short term and long term accuracy shall be as per ITU-T Rec. G.813. 5.1.4 Clock bandwidth The clock bandwidth shall be in the range of 1~10 Hz as specified in ITU-T Rec. G.813 for internal clock and hold-over mode and as per ITU-T Rec. G.812 for transitnode and local-node clock. 5.1.5 Frequency pull-in and pull-out range The minim um pull-in and pull-out range shall be 20ppm for hold-over mode and internal clock. For transit and local node clocks it shall be as per ITU-T Recs. G.812 & G.813. 5.1.6 Timing output interface The SDH equipment shall provide minimum two Timing-Output interfaces. One of them shall be at 2048KHz and the other one at 2048Kbps, both per ITU-T Rec. G.703, for external synchronisation. The output specifications shall conform to ITU-T Recs. G.812 & 813 as applicable. 5.1.7 Specification of clock ports The specification of the input and output port for 2048KHz shall be as under:

5.1.7.1

Specifications of 2048 KHz clock interface


The received digital signal presented at the input port shall be modified by the characteristics of the interconnecting cable. The attenuation of this cable shall be assumed to follow f law and the loss at a frequency 1024KHz shall be in range 0 to 6dB. Return loss at the input port shall be >15 dB.
- 38 -

5.1.7.1.1 Specification at input port

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 39 -

5.1.7.1.1.1 Jitter and wander specifications The input jitter tolerance and input wander tolerance of holdover/internal clock shall be as per ITU-T Rec. G.813. For transit and local node clocks it shall be as per ITU-T Rec. G.812. 5.1.7.1.2 Specification at output port The output port shall meet the specification as given in Table 11/ITU-T Rec. G.703 and shall meet the mask given in figure 20/ITU-T Rec. G.703. The port impedance shall be 120 . 5.1.7.1.2.1 Jitter and wander specifications The output jitter and wander shall be as per ITU-T Rec. G.813 for holdover/internal clock, and for transit as well as local node clocks shall be as per ITU-T Rec. G.812.

5.1.7.2
5.1.7.2.1

Specification of 2048 Kb/s interface Specification at input port The received digital signal presented at the input port shall be modified by the characteristics of the interconnecting cable. The attenuation of this cable shall be assumed to follow f law and the loss at a frequency 1024 KHz shall be in range 0 to 6 dB. Return loss at the input port shall be as follows:
Frequency range (KHz) 51-102 102-2048 2048-3072 Return Loss (dB) 12 18 14

5.1.7.2.1.1 Jitter and wander specifications The jitter and wander at the input port shall be as per ITU-T Recs. G.812 and G.813 as applicable. 5.1.7.2.2 Specification of output port The output port shall meet the specification as given in Table 7/G.703 and shall meet the mask given in figure 15/G.703. The port impedance shall be 120 . Return loss at the input port shall be as under:
Frequency range (KHz) 51-102 102-3072 Return Loss (dB) 6 8

5.1.7.2.2.1 Jitter and wander specifications The jitter and wander at the output port shall be as per ITU-T Recs. G.812 and G.813 as applicable.
- 39 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 40 -

5.1.8

Tributary Re -timing [optional requirement] The equipment shall provide E1 tributary re-timing option w.r.t. local STM-N as1. 2. Separate E1 IO card for re-timing option or; Same card with per-E1 retiming configuration.

The specifications at the input port and output port shall be same as clause 5.1.7 as above.

5.2

Maintenance, Performance Monitoring and Alarm Signals a) ITU-T designated overhead bytes shall provide in-service monitoring. Major alarm signals such as Loss of Signal (LOS), Loss of Frame (LOF), and Loss of Pointer (LOP) resulting in Alarm Indication Signal (AIS) are required to be transmitted downstream. In response to different AIS signals, Remote Defect Indication (RDI)/Enhanced Remote Defect Indication (E-RDI) as applicable is sent upstream. The remote indication operation such as REI & RDI and AIS generation shall be as per Appendix II of ITU-T Rec. G.806. The generation of Enhanced RDI shall be in accordance with Appendix VII of ITU-T Rec. G.783. The generation of Signal Failure and Signal Degradation shall be as per Appendix IV of ITU-T Rec. G.806. The defects, anomalies, correlation, restoration, performance monitoring and consequent actions shall be as defined in ITU-T Recs. G.783 and G.806. The detail of alarms is as given in clause 5.2.1 PART II of the GR. b) Performance monitoring at each level in the maintenance hierarchy is based on Bit- Interleaved-Parity (BIP) checks calculated on frame by frame basis. These BIP checks are inserted in the Overheads associated with the Section and Path. Errors detected in the Higher Order (HO) Path and Lower Order (LO) Path BIPs cause the respective Remote Error Indication (REI) signals to be sent upstream. The REI generation and transmission shall be in accordance with Appendix III of ITU-T Rec. G.806. It shall be possible to assign the programmable threshold to performance monitoring mechanisms such as B1err, B2err, B3err and BIP-2err. The programming of threshold shall be from 1 in 104 to 1 in 109 through software. c) Details for section-level and path-level maintenance & performance monitoring

and signals provided by various byte functionalities shall be as specified in ITU-T Rec. G.707. d) The parameters to be monitored in the system shall be as given in ITU-T Rec. G.783.

- 40 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 41 -

5.2.1

Alarms It shall be possible to monitor the following alarms and consequent actions via EMS & LCT of the equipment. For the classification of the alarms as critical/major/minor/deferred shall be provisioned by different colour LEDs1. 2. 3. 4. 5. 6. 7. 8. 9. Loss of signal (LoS) Loss of Frame (LoF) RS-TIM MS-AIS B-2 Err*.(Excessive) 1x103 MS-RDI AU-AIS AU-LOP HP-UNEQ

10. HP-TIM 11. HP- RDI 12. B-3 Err. (Excessive) 1x10 -3 13. LP- TU-AIS 14. LP- UNEQP 15. LP- TIM 16. TU- LOP 17. TU-LOM 18. V-5 Error* 19. LP- RDI 20. GFP alarms as per ITU-T G.7041 LFD CSF TSF EXM UPM

21. TCM alarms as per ITU-T G.707 Tandem Connection AIS Tandem Connection Outgoing Defect Indication Tandem Connection LOP failure Tandem Connection RDI

22. LCAS alarms as per ITU-T Rec. G.7042.

- 41 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 42 -

5.2.2

Performance degradation counters B1err, B2err, B3err, V5err LP-REI HP-REI MS-REI.

The EMS equipment shall support monitoring of B-errors. Also the EMS shall support monitoring of consequent actions due to Excessive-errors in the higher-order path and lower- order path. On exceeding the B3 and V5 error thresholds, a remoteerror-indication (REI) anomaly shall be sent to the remote-end in the form of HPREI and LP-REI. Similarly, Remote Defect Indications anomalies shall also be created due to defects at the receiving stations.

5.3
5.3.1

Order-wire and User-Data channel


Engineering Order-wire Channels Only E1 or E2 bytes shall be used to provide order-wire channels for voice communication between stations. No other byte shall be used for order-wire applications. The order-wire shall have the facility of selective-calling. The permissibility for VoIP EOW is already spelt out in clause 1.6 in PART II of the GR.

5.3.2

Order-wire Channel Performance The order-wire channel shall be 64 Kb/s PCM channel (or emulated over IP for VoIP EOW) and shall comply with performance requirements laid down in ITU-T Rec. G.712.

5.3.3

User-Data Channels F1 Byte The F1 byte shall provide 64 Kb/s data channels for Path Layer user applications. The physical interface for F-1 byte shall be RS-232/V.11/G.703.

5.3.3.1

5.3.3.2

F2 byte (Optional requirement) The F2 byte shall provide 64 Kb/s data channels for Path Layer user applications. F2 byte may also be used to map DCC information. The interface for F-2 bytes shall be RS-232 /V.11/G.703.

6.0 6.1

Technical Specifications in details SDH Multiplexing Structure The SDH multiplexing structure shall be in accordance with ITU-T Rec. G.707, as detailed in figure 6-1/ ITU-T Rec. G.707.

- 42 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 43 -

6.1.1

Multiplexing method The equipment shall adopt the multiplexing methods for 64 nos. of AUGs into STM64 frame as per ITU-T Rec. G.707. The various multiplexing options of Virtual Containers into STM-N and their position in STM-64 frame shall be as per ITU-T Rec. G.707.

6.1.2

Pointer Applications The equipment shall provide the pointer generation and pointer interpretations as per Para 8/ G.707. The pointer shall accommodate the phase difference of VCn and the SOH as well as differences in the frame rates. The equipment shall process STM-16 AU-pointer, AU-4 pointer, AU-3 pointer, AU pointer of other mapped tributaries - TU-3 pointer and TU12 pointer etc., (as applicable) as specified in Para 8/ ITU-T Rec. G.707.

6.1.3

Section Overhead The SOH shall be added to the payload to create an STM-16 signal. The SOH information shall further be classified in to Regenerator Section Overhead {RSOH} and Multiplex Section Overhead {MSOH}. The termination of Regenerator Section Overhead shall be done at the Regenerator and Multiplexers; whereas the termination of Multiplex Section Overhead shall only be done at Multiplexers. The Section Overhead and its various functions shall follow the recommendations given in Para 9/ ITU-T Rec. G.707.

6.1.4

Regenerator Section Over-Head (RSOH) The Regenerator Section Overhead shall provide the following bytes as per ITU-T Rec. G.707A1, A2 J0 B1 E1 F1 D1, D3 : : : : : : Framing bytes Regenerator-Section trace byte BIP-8 , error monitoring byte Engineering Order-wire byte User channel byte 192 Kbps Regenerator-Section DCC bytes

6.1.5

Multiplex Section Over-Head (MSOH) The Multiplex-Section Overhead shall provide the following bytes as per ITU-T Rec. G.707B2 K1, K2 : : BIP-Nx24, Error Monitoring bytes Automatic Protection switching, APS bytes

- 43 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 44 -

D4, D12 E2 S1 M1 Z0

: : : : :

576 Kbps Multiplex-Section DCC bytes Engineering Order-wire bytes Synchronization Status Message byte Multiplex Section Remote Error Indication byte Spare byte

The STM-16 Section Over-Head shall be as per figure 9-4/ITU-T Rec. G.707. 6.1.6 Virtual Container POH Two categories of Virtual Container POH shall be supported by the SDH equipment.

6.1.6.1 Higher Order Virtual Container POH: VC-4/VC-3 POH


The VC-4 and VC-3 POH shall be located in the first column of the container VC-4 and VC-3 POH shall be as underJ1 B3 C2 G1 F2 H4 F3 K3 N1 : : : : : : : : : Path trace byte Path BIP8 byte Signal Label byte Path Status byte Path User Channel byte Position Indicator byte Path User Channel byte Automatic Protection Switching Channel byte Network Operator TCM byte

6.1.6.2

Lower Order Virtual Container POH: VC-3/VC-12 POH VC12 POH shall be as followsV5 J2 N2 K4 : : : : Error Monitoring byte Path trace byte Network operator TCM byte Automatic Protection Switching byte

The exact function for K3, K4 shall be as decided by ITU-T but the equipment shall support K3 & K4 bytes.

6.2

Mapping of Tributaries into Virtual Containers (VCs) The accommodation of asynchronous and synchronous tributaries as defined in ITUT Rec. G.702 shall be possible. The equipment shall support asynchronous mapping of 2Mbps, 34Mbps/DS3 PDH signals into their respective VCs as specified in Para 10/ITU-T Rec. G.707.

- 44 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 45 -

Also the equipment shall support byte synchronous mapping of 2048 Kb/s signals. The system shall support TUG-3 structured multiplexing chain to form AU-4. 6.2.1 Information payload The payload structure shall be organised in accordance with ITU-T Recommendations given in Para 6.2.2/ITU-T Rec. G. 707. 6.2.2 Maintenance signals The maintenance signals shall be as per Para 6.2.4/ITU-T Rec. G.707. 6.2.3 Tandem Connection Monitoring The system shall support the Tandem Connection Monitoring at VC4 and VC4-Xc level as per ITU-T Recs. G.707, G.783 and G.803, using N1 byte in Higher Order Path. The path performance degradation and path failure alarms shall be provided as per ITU-T Rec. G.707.

6.2.4 6.2.4.1

Concatenation & Encapsulation mechanisms


Contiguous Concatenation The equipment shall support contiguous concatenation @VC4 level as specified in Para 11.1/ITU-T Rec. G.707. The system shall support termination of VC4-4c, VC416c interfaces and their cross-connection as well. The system shall provide an optional capability for translation of a contiguous concatenated payload in to a VCG (and vice-versa).

6.2.4.2

Virtual Concatenation The equipment shall support virtual concatenation at VC12, VC3 and VC4 levels as specified in Para 11.2/ITU-T Rec. G.707. The details of VCG shall be as per clause 6.5.4 in PART II of this GR.

6.2.5

Generic Framing Procedure The equipment shall support the encapsulation of Ethernet and other higher-layers clients data through GFP-Framed as well as GFP-Transparent as specified in ITU-T Rec. G.7041. Preferably, the system shall provide per Ethernet port selection for either GFP-F or GFP-T (as applicable). However, separate Ethernet cards for both GFP encapsulations shall also be permitted.

6.2.6

Link Capacity Adjustment Scheme The equipment shall support Link Capacity Adjustment Scheme as specified in ITUT Rec. G.7042. The addition/deletion of VCns from a VCG shall be hitless. Implementation of LCAS in the system shall not introduce/contribute additional latency in the data path.

- 45 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 46 -

6.2.6.1

LCAS requirements LCAS signalling between peers shall be carried in the SDH path overhead as outlined in ITU-T Recs. G.7042 and G.707. The following LCAS capabilities shall be supported.
Basic LCAS Operation LCAS and 1+1 Path Protection LCAS Group Identifiers Asymmetric LCAS LCAS inter-working.

The LCAS feature specified above shall be applicable to all Virtually Concatenated payloads configurable through EMS/LCT.

6.2.6.2

Asymmetric LCAS Asymmetric LCAS arises when an LCAS-enabled VC bundle is configured with different bandwidth in each direction. Equipment shall correctly transmit and receive Ethernet data when some (but not all) of the members of the bundle are unidirectional paths. In addition, the equipment shall correctly transmit and receive Ethernet data when some (but not all) of the members of the bundle are bi-directional paths that have failed in only one direction.

6.2.6.3

LCAS Inter-working When two nodes use virtual concatenation for a network connection, it shall be possible that one side is configured to use LCAS on the connection, and the other side is not (or does not support LCAS). That is, when a node is using LCAS on a VC bundle (i.e. LCAS configuration is enabled), it shall send LCAS control-messages. If a node does not receive any LCAS control messages, it shall assume that the peer is not using LCAS.

6.3

Ethernet Service requirements The following services shall be offeredPoint-to-Point Dedicated (P2PD) A point-to-point dedicated service shall map Ethernet traffic into one transport path and transport the traffic to another Ethernet interface on the far end. There is no aggregation at either side of the network. Alternatively, the Ethernet traffic from one port can be mapped on a module to another. The P2PD service is used to offer dedicated Ethernet Private Line services.

- 46 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 47 -

Point-to-Point Shared (P2PS) A point-to-point shared service shall map Ethernet traffic from multiple Ethernet interfaces on one Ethernet IO module into one transport path and shall transport the traffic across the network to another Ethernet module. The P2PS service is used to offer Ethernet Virtual Private Line services. Internet Access Service (IAS) An Internet access service shall allow multiple subscribers access the hub-site router for Internet access. This service shall aggregate traffic in two locations: at the subscriber side and at the hub-site. On the subscriber site, the node shall statistically multiplex Ethernet traffic from multiple Ethernet ports on the same card onto a transport path. At the hub-site, the node shall statistically multiplex traffic from multiple transport paths onto one single Ethernet interface. The IAS service is used to offer shared Ethernet access to Internet services. Transparent LAN Service (TLS) A transparent LAN service shall allow multiple Ethernet devices in multiple locations to appear as a single private LAN (virtual LAN or VLAN). Each device shall attach to an Ethernet port on an individual node. Each node shall connect to another node in a point-to-point or linear-chain topology. Each Ethernet device can exchange data with any other device on the LAN with the same virtual identifier (VLAN). The transparent LAN services can be configured for individual customers (separate Ethernet devices) but shall share the trunk bandwidth between nodes. Apart from the same, there shall be support for point to point, point to multi-point as well as multi-point to multi-point services on all Ethernet ports in accordance with ITU-T & MEF standards, as defined previous and subsequent clauses in the GR. 6.3.1 Layer 2 Service Implementation Requirements The equipment shall support VCAT/GFP over any of the SDH interfaces in the equipment, and shall aggregate the packet traffic through packet-switching subsystem (Ethernet MAC), and encapsulate the packet traffic within GFP/VACT/LCAS channels and forward the same over various STM-N interfaces in the system. This mechanism shall provide significant efficiency while transporting data through the SDH network through the following features: 1. Right sizing the VCAT pipe for point to point Ethernet-Lines (EPL, EVPL etc.) services.

- 47 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 48 -

2. Right sizing the VCAT pipe for multi-point to multi-point Ethernet-LAN (EPLAN, EVPLAN etc.) services. 3. Idle packet suppression only packets containing customer data shall be transported through the egress interface. This is to reduce the capacity requirements of the egress interfaces, number of such egress interfaces, and the capacity requirements on the Router interfaces that connect to the equipment for further service creation. 4. Statistical multiplexing with SLA shall facilitate the purchaser to offer data services at multiple QoS classes with different SLA contracts.

6.3.1.1

Service QoS Implementation


Point to point data private-line service shall be offered through right-sized GFP/VCAT with guaranteed bandwidth between the two end points.

6.3.1.1.1 Fixed-rate Point to Point Ethernet Private Line service

6.3.1.1.2 Burtsable Ethernet Private Line & LAN service Burtsable Ethernet Private Line & LAN service is a service instance wherein traffic from multiple Ethernet user-ports shall be aggregated using 802.1Q & 802.1ad defined Q-in-Q and transported through VCAT/GFP, for shared private line & LAN services. This shall be an overbooked service. The devices shall offer layer-2 traffic management and OAM features, such as port-rate limiting, ingress policing, troubleshooting etc. The SLA (service level agreements) for such services shall include CIR (Committed Information Rate), EIR (Excess Information Rate), COS (upto 4 classes of service) with 802.1P classification. This service shall facilitate node-based over-subscription. Thus bandwidth allocation between two SDH nodes on a ring shall be allocated permanently (for example STM1-2v), and traffic from multiple Ethernet customers shall be multiplexed with CIR/EIR (as configured) overbooking through VCAT path. 6.3.1.1.3 Additional layer 2 service attributes

The system shall provide layer-2 encapsulation and forwarding through MPLS using PWE3 as per RFC-3916 & IETF draft Martini draft-ietf-pwe3-ethernetencap-09.txt and related drafts. [optional requirement]

Solid demarcation point between provider and customer, in the form of MEF UNI1.0. Per customer unique identifiers for SLA monitoring and service identification. [optional requirement]

Ethernet OAM&P support for connectivity verification across the network, and within the network.

- 48 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 49 -

6.3.2

IEEE 802.3ad link aggregation and protection on service and trunk ports.

Layer 2 functionality details & specifications In order to realise the above-mentioned services, there shall be in-built layer-2 bridging & aggregation functionality as per IEEE 802.1D in the system. The implementation for the same is described in clause 6.3.3. There shall be support for VLAN stacking (Q-in-Q) per IEEE 802.1ad on all ports. The users shall be identified based on MAC address/Physical port of arrival/VLAN-ID (C-VLAN) @IEEE 802.1q, as configured. There shall be customer and provider MAC address separation and learning. The transport-side VLAN (S-VLAN) shall be configured through LCT/EMS. For Ethernet Virtual Private Lines (EVPL) & Ethernet Virtual Private LAN (EVPLAN) services, multiple Ethernet user-ports shall share a configured VCG between two points. The VCG selection shall be autonomous based on VLAN-ID, MAC based, and port based which shall be configured through EMS & LCT. The VCG selection may also be pre-configured through EMS. The purchaser shall convey exact requirements. Also there shall be provision for non-shared VCAT bandwidths against specific Ethernet ports which shall be used for Ethernet Private Lines (EPL). Either the support for EPL, EVPL, EPLAN, and EVPLAN services shall be configurable per Ethernet port on a common IO card or standalone Ethernet IO cards shall be provided for shared and dedicated access. The service requirements of MEF and ITU-T Recs. G.8010, G.8011, G.8011.x series shall be complied for Ethernets services. Some of the service i plementation m details are given in the following sections. Exact details regarding VLAN administration for connectivity services are outlined in Appendix II of the GR. Ethernet Private Line/LAN service Each Fast Ethernet port shall be configured with a backhaul bandwidth VC12-Xv where X=1 to 46 against a particular port, configured through EMS/LCT. The support for VC3-Xv where X=1-2, shall be optional to purchasers requirements. Similarly each GigE port shall be configured with a backhaul bandwidth VC4-Xv where X = 1 to 7 configured through EMS/LCT. The virtual concatenation shall be implemented in accordance with ITU-T Rec. G.707 at VC12, VC3 (optional) & VC4 and shall be configurable through EMS/NMS/LCT for each Ethernet port. Virtual Private Line/LAN service Same as for Ethernet Private Line/LAN service but with the following additional requirements- 49 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 50 -

The system shall perform layer-2 aggregation of the Ethernet user-flows sensitive to the C-VLANs carried in the terminated Ethernet flows at Ethernet user ports. There shall be VLAN-based VCAT selection through EMS, for backhaul. Various Ethernet flows across multiple Ethernet user-ports on an IO card with specific CVLAN shall be aggregated and backhauled through a configured VCAT group (VCG). The QoS requirements are already spelt out before.

6.3.2.1

Details of Ethernet interface provisioning The equipment shall support a minimum of 8 nos. of 10/100BaseT cards in ADM mode. This assumes 8 nos. Fast Ethernet ports per IO card. Similarly, the equipment shall support a minimum of up to 4 Gigabit Ethernet ports in ADM mode. In case, no. of Ethernet ports supported per card is more, the quantity of Ethernet IO cards shall go down accordingly.

6.3.3

Layer-2 Switching/Aggregation Implementation The GR envisages layer-2 aggregation for Fast Ethernet interfaces and for Gigabit Ethernet interfaces. Some of the possible provisions for Ethernet interfaces are1. IO cards with multiple Fast Ethernet (recommended minimum 8 ports for this

GRs compliance) and one or more Gigabit Ethernet ports each.


2. Separate IO cards for Fast & Gigabit Ethernet interfaces.

The equipment shall implement layer-2 aggregation as a centralised switch. However, implementation of layer-2 switch at Ethernet IO card-level shall also be acceptable provided inter-IO card cross-connections at MAC layer are possible. In case of MAC switch-fabric failure on one IO card, the system shall bridge local Ethernet user traffic to a MAC switch fabric for layer-2 processing on a backup IO card through autonomous arrangements. In case of IO card level layer-2 aggregation, there may be a common backup IO card provided, with redundancy in (N:1) mode for all Fast Ethernet IO cards and Gigabit Ethernet IO cards (provision option #2 as above). Similarly, there may be a common backup IO card provided, with redundancy in (N:1) mode for all {Fast+Gigabit} Ethernet IO cards (provision option #1 as above). The switch-fabric capacity shall be as specified for a Gigabit Ethernet IO card (in case it is a standalone card refer provision option #2). In such case, the configurations for the Ethernet traffic (for the IO card on which MAC switch failure has occurred) shall be maintained. In case of layer-2 aggregation at IO card-level, the layer-2 switch-fabric for individual Fast Ethernet

- 50 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 51 -

IO cards shall be minimum 2.4Gb/s (assuming 8 Fast Ethernet ports per IO card). The capacity shall increase on pro-rata basis if the number of Fast Ethernet ports is more than 8 per IO card. If provided as combined {8 FE+1GigE} per IO card, it shall implement minimum 4.8Gb/s MAC switch-fabric. If there are standalone Gigabit Ethernet IO cards, it shall provide a minimum of 6Gb/s MAC fabric. The equipment shall support a minimum of 64 nos. of Fast Ethernet interfaces in ADM mode & 32 nos. Fast Ethernet interfaces in TM mode. There shall be provision in the system to provide up to 4 nos. of Gigabit Ethernet interfaces in ADM mode. There shall be minimum 2 Gigabit Ethernet ports per GigE IO card. The manufacturer shall ensure support for at least 1000BaseLX and LH @1310nm interfaces. 1000BaseSX multi-mode interfaces shall be optional to purchasers requirements. The purchaser shall communicate exact interface requirements for 1000BaseSX/LX/LH. The switch fabric requirements in case of centralised MAC switch implementation shall be 2.4*8 + 2*6~ 30Gb/s for ADM mode (for standalone cards for Fast & Gigabit Ethernet) and 4.8*8 ~ 36Gb/s for combined Gigabit Ethernet IO card. There shall be a hot-standby redundant MAC switch of equal capacity for failures. The aggregated Ethernet traffic from central layer-2 switches or IO cards (depending upon implementation) shall be encapsulated using GFP techniques and mapped onto SDH payload through virtually concatenated VCns (VCGs) with configurable LCAS implementation. Note: The description of Ethernet switch-fabric considers each of the TX and RX direction of an Ethernet interface as separate for calculation of switch-fabric. The TX & RX direction of a Gigabit Ethernet interface is taken as equivalent of 1Gb/s in calculating the fabric capacity. Similarly, each of the TX & RX direction of a Fast Ethernet interface is taken as equivalent of 100Mb/s in calculating the fabric capacity. And an over-subscription ratio @2:1 is assumed. According to this description methodology, one GigE user-interface necessitates provision of 3Gb/s MAC switch-fabric and similarly one Fast Ethernet interface necessitates provision of 300Mb/s MAC switch-fabric.

6.3.3.1

Bridging specifications
1. 2. 3. 4.

VLAN IEEE 802.1Q support on all ports VLAN priority IEEE 802.1P support on all ports IEEE 802.1s RSTP support on all ports IEEE 802.1ad Q-in-Q on all ports

- 51 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 52 -

5.

IEEE 802.3ad LAG on all trunk ports for aggregation up to 4 ports.

6.3.3.2

Bandwidth granularity @64kbps Fast Ethernet with rate limiting per port through LCT & EMS. @1Mbps GigE with rate limiting per port through LCT & EMS.

6.3.4

Ethernet Provisioning VCAT details The Ethernet interface provisioning is envisaged through Ethernet interface cards. In Ethernet Private Lines {E-LINE}/LAN {E-LAN} applications, a bandwidth in the form of a Virtual Concatenated Group (VCG), VCn-Xv where n=12, 3 & 4 shall be provided at the backhaul of these Ethernet interfaces as per the following details: Fast Ethernet 10/100BaseT & 100BaseFX

VC12-Xv VC3-Xv

where X=1 to 46 and, where X=1 to 2 (optional to purchasers requirements).

Gigabit Ethernet 1000BaseSX/LX/LH


VC4-Xv VC3-Xv

where X=1 to 7 and, where X=1 to 21 (optional to purchasers requirements).

The bandwidth, so provisioned, for a particular Ethernet port shall be indicated through GUI on the NMS/EMS (or LCT) server as well as shall be available in printable format for Service Level Agreement (SLA) obligations & for QoS certification. Note: The unutilized bandwidth after Ethernet backhaul applications shall not be blocked for other tributary applications.

6.4

Network Node Interfaces - Details


There shall be three types of Network Node Interfaces, namely1. SDH interfaces The SDH interfaces for STM-1o, STM-4o, STM-16o and STM-64o shall conform to ITU-T Recs. G.957 and G.783 and STM-1e shall conform to ITU-T Rec. G.703. The shorthaul application code S 16.1, S 4.1 and S 1.1 shall be sufficient for SDH interfaces at STM-16o, STM-4o and STM-1o respectively, for compliance to this GR. 2. PDH interfaces The 2Mbps, 34Mbps/DS-3 PDH electrical interfaces shall be compliant to ITU-T Rec. G.703.

- 52 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 53 -

3. Ethernet on SDH interfaces The equipment shall support IEEE 802.3 standard 10/100BaseT, 100BaseFX, 1000BaseSX* (optional), 1000BaseLX and 1000BaseLH (at 1310nm) single-mode Ethernet interfaces for transport of over SDH in accordance with ITU-T Rec. G.7041 (GFP). The provision for 1000BaseSX shall be optional to purchasers requirements. 4. Transparent SAN interfaces The equipment shall support Storage Area Network (SAN) interfaces - FC, FICON, ESCON and DVB-ASI video interface. The encapsulation of SAN data shall be as per GFP-T mode, specified in ITU-T Rec. G.7041.

6.5

Window of Operation 1550nm as per ITU-T G.957/G.691.

6.6

Optical Line Interface : STM-64 interface


The optical line interfaces are required to provide the interface between two line equipments connected by an optical path, with possible intermediate regeneration, if needed. It is intended to achieve transverse compatibility within any signal in the optical section. The equipment shall meet the optical interfaces specifications @ S 64.2a or S 64.2b (on G.652 fibre) and S 64.5a or S 64.5b (on G.655 fibre) at 1550 nm as per ITU-T Rec. G.691. The target distances supported by this optical interface shall be 40kms. approximately based on ITU-T assumption of fibre attenuation @ 0.275dB/Km. at 1550nm with a span loss of 11dB. Note The distances are meant for classification only, and not for specification purpose. The actual coverable distances will depend on the attenuation & dispersion characteristics of the fibre.

6.7

Digital Signal The STM-64 line shall be in accordance with ITU-T Recs. G.691, G.707 and G.783.

6.7.3

Nominal bit-rate The nominal bit-rate in the synchronised mode shall be in accordance with ITU-T Rec. G.811. The nominal bit rate in the free-running mode shall be as follows. STM-64 9953.280Mb/s 4.6ppm (nominal).

- 53 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 54 -

6.7.4

Optical parameters The optical parameter values for the specified application-code shall meet the requirements given in ITU-T Rec. G.691 for the system operating wavelengths specified therein.

6.7.5

Receiver Sensitivity The values given in ITU-T Rec. G.691 against minimum sensitivity of receiver at reference point "R" are worst case end-of-life {EOL} values for long haul application. The beginning-of-the-life {BOL} values are specified to be 2-4dB better than the given values in above referred tables.

6.7.6

Eye pattern The shape of the optical pulse of the transmitter at reference point S, shall conform to the eye pattern mask as given in ITU-T Rec. G.691. Type of connectors FC-PC/SC/LC connectors shall be provided at FDF/ODF end. In case, other than FC-PC connectors viz., LC, SC, etc., are provided at the equipment-end, suitable adapters/patch-cords etc., shall be provided by the manufacturer as an integral part of the offer.

6.8

Jitter and Wander Performance Jitter requirements for optical for optical interfaces at STM-64 level shall be as given in Para15/ITU-T Rec. G.783. The STM-64 wander parameters shall be per ITU-T Rec. G.813.

6.8.3

SDH interfaces - Jitter and Wander The jitter and wander specifications of SDH interfaces at STM-64 aggregate level shall be as per ITU-T Recs. G.783, G.825, G.811 and G.813 as applicable.

6.8.3.1

Jitter and Wander Generation The output jitter and wander shall meet short-term stability as specified in table 6/ITU-T Rec. G.813 and table 7/ITU-T Rec. G.813. Further, the equipment shall meet the jitter and wander limits as specified in ITU-T Rec. G.783.

6.8.3.2

Jitter and Wander Transfer The jitter and wander transfer function of an SDH regenerator shall be under the curve given in ITU-T Rec. G.783, when input sinusoidal jitter up to the mask level specified in ITU-T Rec. G.783, is applied. The jitter and wander transfer guidelines shall be as per Para 15/ ITU-T Rec. G.783.

- 54 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 55 -

6.8.3.3

Jitter and Wander Tolerance SDH Terminals, ADM and regenerators shall meet the jitter tolerance specifications given in ITU-T Rec. G.783, with reference to figure 15.2/ITU-T Rec. G.783 with parameters specified for various types and bit rates.

6.8.3.4

Transfer of wander encoded in AU and TU pointer adjustments Shall conform to Para 10.1.4/ ITU-T Rec. G.783.

6.9
6.9.3

Optical Tributary Interfaces


STM-16 optical interface The STM-16 interface shall be in accordance with ITU-T Recs. G.957, G.707 and G.783.

6.9.3.1

Nominal bit-rate The nominal bit-rate in the synchronised mode shall be in accordance with ITU-T Rec. G.811. The nominal bit rate in the free-running mode shall be as follows. STM-16 2488.320 Mb/s 4.6ppm (nominal).

6.9.3.2

Optical parameters The optical parameter values for the specified application code shall meet the requirements given in table 4/ITU-T Rec. G.957 for system operating wavelengths specified therein. The definitions of the various parameters are as given in Para 6/ITU-T Rec. G.957.

6.9.3.2.1

Receiver Sensitivity The values given in the table 4/ ITU-T Rec. G.957 against minimum sensitivity of receiver at reference point "R" are worst case end-of-life {EOL} values for long haul application. The beginning-of-the-life {BOL} values are specified to be 2-4dB better than the given values in above referred tables.

6.9.3.2.2

Eye pattern The shape of the optical pulse of the transmitter at reference point S, shall conform to the eye pattern mask as given in Figure 2/ITU-T Rec. G.957. Type of connectors FC-PC/SC/LC connectors shall be provided at FDF/ODF end. In case, other than FC-PC connectors viz., LC, SC, etc., are provided at the equipment-end, suitable adapters/patch-cords etc., shall be provided by the manufacturer as an integral part of the offer.

- 55 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 56 -

6.9.3.3

Jitter and Wander Performance Jitter requirements for optical for optical interfaces at STM-16 level shall be as given in Para15/ITU-T Rec. G.783. The STM-16 wander parameters shall be per ITU-T Rec. G.813.

6.9.4

STM-4 optical interface The STM-4 line signal shall be as per ITU-T Recs. G.707 & G.783. Nominal bit-rate 622.080 Mb/s4.6ppm (Nominal)

The STM-4 tributary signal shall be in accordance with ITU-T Recs. G.707 & G.783. The nominal bit rate in the synchronized mode shall be traceable to ITU-T Rec. G.811. The nominal bit-rate in the free-running mode shall be 155.520Mb/s +/4.6ppm.

6.9.4.1

Optical Parameters The STM-4o traffic interfaces shall meet optical interface specifications for shorthaul inter-office application, S 4.1, as per ITU-T Rec. G.957 in 1330nm window using ITU-T Rec. G.652 single mode fibre. However, S 4.2 application as per ITU-T Rec. G.957, in 1550nm window, shall also be acceptable.

Note:

However, the purchaser may demand other ITU-T Rec. G.957 application codes i.e., long-haul inter-office applications in 1330nm and/or 1550nm window using ITU-T Rec. G.652 single-mode fibre, @L 4.1 & L 4.2 respectively.

6.9.4.1.1

Eye Pattern Mask The shape of the optical pulse of the transmitter at reference point S, shall conform to the eye pattern mask as given in figure 2/ITU-T Rec. G.957. Type of connectors FC-PC/LC/SC connectors shall be provided at FDF/ODF end. In case, any other type of connectors viz., LC, SC etc., are provided at the equipment, suitable adapters/patch-cords etc., shall be provided by the manufacturer as an integral part of the offer.

6.9.4.1.2

Receiver Sensitivity The receiver sensitivity values for the specified application-code shall meet the requirements given in table-4/ITU-T Rec. G.957, as reproduced at the end of the GR, for the system operating wavelengths specified therein. All values specified in the table are end-oflife {EOL} values. The beginning of the life {BOL} values shall

- 56 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 57 -

be specified 2-4dB better than the given values. Receiver sensitivity shall be provided as per S1.1 application at 1310nm or S1.2 at 1550nm application.

6.9.4.2

Jitter and Wander Performance Jitter requirements for optical for optical interfaces at STM-4 level shall be as given in ITU-T Rec. G.783. The STM-4 wander parameters shall be per ITU-T Rec. G.813.

6.9.5

STM-1 optical interface The STM-1 line signal shall be as per ITU-T Recs. G.707 & G.783. Nominal bit-rate 155.520 Mb/s.

The STM-1 line signal shall be in accordance with ITU-T Recs. G.707 & G.783. The nominal bit-rate in the synchronized mode shall be traceable to ITU-T Rec. G.811. The nominal bit- rate in the free-running mode shall be 155.520Mb/s +/- 4.6ppm.

6.9.5.1

Optical Parameters The STM-1o traffic interfaces shall meet optical interface specifications for shorthaul inter-office application, S 1.1, as per ITU-T Rec. G.957 in 1330nm w indow using ITU-T Rec. G.652 single mode fibre. However, S 1.2 application as per ITU-T Rec. G.957, in 1550nm window, shall also be acceptable.

Note: However, the purchaser may demand other ITU-T Rec. G.957 application codes i.e., long-haul inter-office applications in 1330nm and/or 1550nm window using ITU-T Rec. G.652 single-mode fibre, @L 1.1 & L 1.2 respectively. 6.9.5.1.1 Eye Pattern Mask The shape of the optical pulse of the transmitter at reference point S, shall conform to the eye pattern mask as given in figure 2/ITU-T Rec. G.957. Type of connectors FC-PC/LC/SC connectors shall be provided at FDF/ODF end. In case, any other type of connectors viz., LC, SC etc., are provided at the equipment, suitable adapters/patch-cords etc., shall be provided by the manufacturer as an integral part of the offer. 6.9.5.1.2 Receiver Sensitivity The receiver sensitivity values for the specified application code shall meet the requirements given in table 4/ITU-T Rec. G.957, as reproduced at the end of the GR, for the system operating wavelengths specified therein. All values specified in the table are end of life values. The beginning of the life values shall be specified

- 57 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 58 -

2-4dB better than the given values. Receiver sensitivity shall be provided as per S1.1 application at 1310nm or S1.2 at 1550nm application.

6.9.5.2

Jitter and Wander Performance Jitter requirements for optical for optical interfaces at STM-1 level shall be as given in ITU-T Rec. G.783. The STM-1 wander parameters shall be per ITU-T G.813.

6.9.6 6.9.6.1

STM-1 Electrical Interface


General Characteristics The interface requirements for STM-1 tributary interface shall be as per Para 12/ ITU-T Rec. G.703. Nominal bit rate Tolerance Code Over-voltage protection : 155520 kb/s : 20ppm : CMI (Code Mark Inversion) : ITU-T Rec. K.41.

6.9.6.1.1

Specifications at the input ports The digital signal presented at the input port should conform to table 11/ ITU-T Rec. G.703 and figures 22 & 23/ITU-T Rec. G.703 modified by the characteristics of the interconnecting coaxial pair. The attenuation of the coaxial cable should be assumed to follow an approximate f law and to have a maximum insertion loss of 12.7dB at a frequency of 78 MHz. The return loss characteristics should be the same as that specified for the output port.

6.9.6.1.2

Specifications at output ports The specifications at the output port are given as below and as per figures 22 & 23/ ITU-T Rec. G.703. Return Loss : 15 dB over freq. range 8 MHz to 240MHz.

6.9.6.1.3

Specifications at the Cross-Connect Points The signal power level and eye diagram requirements shall be as specified in Para 15.4/ ITU-T Rec. G.703. Type of connector: BNC/Spinner/SMA/SMB.

6.9.6.2

SDH interfaces - Jitter and Wander Refer clause 8.1.2.3 in Part II of TEC GR No.: GR/SDH-10/02.MAR.2005 for STM-4 Synchronous Multiplexer.

- 58 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 59 -

6.10
6.10.3

PDH Tributary Interfaces 34 Mb/s Electrical Tributary Interface The Interface requirements for the 34 Mb/s Tributary Interface shall be as per ITU-T Rec. G.703.

6.10.3.1

General characteristics Bit rate Code 34368 Kb/s 20ppm HDB3.

6.10.3.2

Specification at output ports The specification at output ports are given as below and as per figure 17/ITU-T Rec. G.703.
(a) Pulse shape (b) Pairs in each direction (c) Test load impedance (d) Peak voltage of a mask (pulse) (e) Peak voltage of a space (no pulse) (f) Nom. pulse width (g) Ratio of the amplitudes of positive and negative pulses at the centre of a pulse interval (h) Ratio of the width of positive and negative pulses at nominal half amplitude Nominally rectangular and conforming to the masks shown in Figure 17/ ITU-T Rec. G. 703, irrespective of sign. One coaxial pair 75 ohms resistive 1.0 V 10% 1.0 V 10% 14.55 ns 0.95 to 1.05 0.95 to 1.05

Note:

Refer to Figure 17 / ITU-T Rec G. 703 for (b) to (h) above. Return Loss The Return loss at output port shall be as followsFrequency Range (kHz) 860 to1720 1720 to 51550 Return Loss (dB) 6 8

Type of connector: BNC/Spinner/SM A/SMB.

6.10.3.3

Specifications at the input ports The digital signal presented at the input port should conform to table 8/ITU-T Rec. G.703 and figure 17/ITU-T Rec. G.703 modified by the characteristics of the interconnecting coaxial pair. The attenuation of the coaxial cable should be assumed to follow an approximate "square root of f" law and to have a maximum insertion loss of in the range of 0 to 12 dB at a frequency of 17184 KHz. The Return loss at the input port shall be as followsFrequency range 860 KHz to 1720 KHz Return Loss >12dB

- 59 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 60 -

720KHz to 34368 KHz 34368 to 51550KHz

>18dB >14 dB

6.11

2 Mb/s Electrical Interface The Interface requirements for the 2 Mbps Tributary Interface shall be as per ITUT Rec. G.703.

6.11.3

General Characteristics Bit rate Code : 2048 kb/s 50 ppm : HDB3.

6.11.4

Specification at the input ports The digital signal presented at the input port shall be modified by the characteristics of the interconnecting cable. The attenuation of this cable shall be assumed to follow f law and the loss at a frequency 1024 KHz shall be in the range 0 to 6 dB. Return loss at the input port shall be as follows:
Frequency Range (kHz) 51.2 KHz to 102.4KHz 102.4KHz to 2048 KHz 2048KHz to 3072KHz Return Loss (dB) >12dB >18dB >14dB

6.11.5

Specification at output ports The specifications at the output port are given as below and as per figure 15/ ITUT Rec. G.703.
Frequency Range (kHz) 51 to102 102 to 3072 Return Loss (dB) 6 8

Type of connector Wire-wrapping type, the wire-wrapping pin should be able to take wire 0.6 mm diameter. Alternatively IDC type or D-type terminations shall also be acceptable. The wire diameter in the case of IDC and D-type termination shall be min. 0.5 mm diameter. The crimping tool and a minimum of 20m connection-cable shall be supplied as an integral part of the offer.

6.12

44.736 Mb/s Electrical interfaces (DS-3) The electrical interface of 44.736 Mb/s shall be as per clause 8 of ITU-T Rec. G.703. The card for DS3 interface must be software configurable as a 34Mb/s card

- 60 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 61 -

to accept a 34Mb/s PDH signal as defined in ITU Rec. G.703. The electrical interface for 34Mb/s signal shall be in accordance with ITU Rec. G.703 and the multiplexing of 34 Mb/s signal to SDH hierarchy shall be as per ITU Rec. G.707. Nominal line rate 6.12.3 Line-rate accuracy In a self -timed, free-running mode, the line-rate tolerance shall be 895bits/s ( 20ppm) or better. 6.12.4 Line code B3ZS (bipolar with three-zero substitutions). 6.12.5 Frame structure The signal shall have the frame structure defined in ITU-T Rec. G.752. 6.12.6 Medium Unbalanced coaxial line shall be used for each direction of transmission. 6.12.7 Test load impedance Unbalanced 75 ohms coaxial line shall be used for each direction of transmission. 6.12.8 Pulse shape The shape of every pulse that approximates an isolated pulse (is preceded by two zeros and followed by one or more zeros) shall conform to the mask in Figure 14 of ITU Rec. G.703. See clause 5.2 of ITU Rec. G.703 for allowable procedures to be followed in checking conformance. This mask includes an allowance of 3% of the peak pulse amplitude at any point on the mask relative to the pulse mask in the earlier version. 6.12.9 Power level A wideband power measurement of an AIS signal (as defined in Recommendation G.704) using a power level sensor with a working frequency range of 200 MHz shall be between 4.7 dBm and +3.6dBm, including the effects of a range of connecting cable lengths between 68.6 meters (225 feet) and 137.2 meters (450 feet). A low-pass filter having a flat pass-band and cut-off frequency of 200 MHz shall be used. important; or an alternate power level specification of the power of an all-ones signal (Note 2/ ITU Rec. G.703) is useful for some equipment qualifications. It requires that the power in a 3 kHz 1 kHz band centred at 22,368 kHz be between 1.8dBm and The roll-off characteristics of this filter are not : 44. 736 Mb/s

- 61 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 62 -

+5.7 dBm. It further requires that the power in a 3 kHz 1 kHz band centred at 44,736 kHz be at least 20dB below that at 22 368 kHz. 6.12.10 Pulse imbalance 1. The ratio of amplitudes of positive and negative isolated pulses shall be between 0.90 and 1.10. 2. Positive and negative isolated pulses shall both conform to the mask of Figure 14/ ITU Rec. G.703. 6.12.11 DC power There shall be no DC power applied at the interface. 6.12.12 Verification access Access to the signal at the interface shall be provided for verification of signal specifications. Type of connector: BNC/Spinner/SMA/SMB. 6.12.13 6.12.14 PDH interfaces Jitter and Wander 2/34Mbps The input jitter and wander tolerance shall be as per ITU-T Rec. G.823.

6.12.14.1 Input Jitter and Wander Tolerance 6.12.14.2 Jitter and Wander Transfer characteristics
The jitter and wander characteristics shall be per ITU-T Rec. G.823.

6.12.14.3 Jitter and Wander Generation


6.12.14.3.1 Jitter and Wander from tributary mapping Jitter and wander from the tributary mapping shall be as specified in ITU-T Rec. G.783. 6.12.14.3.2 Jitter and Wander from pointer adjustments Jitter and wander from pointer adjustments shall be as specified in ITU-T Rec. G.783. 6.12.14.3.3 Combined Jitter & Wander from tributary-mapping and pointer adjustments Combined jitter and wander from tributary mapping and pointer adjustments shall be as per ITU-T Rec. G.783. 6.12.15 DS-3 interface - Jitter and Wander The maximum permissible jitter tolerance shall be as per table-1/ITU-T Rec. G.824.

6.12.15.1 Maximum permissible jitter tolerance

- 62 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 63 -

6.12.15.2 Output wander


The wander at the output of interface shall not exceed the limits as specified in table-3/ITU-T Rec. G.824.

6.12.15.3 Input jitter and wander tolerance


Input jitter and wander transf er characteristics shall be as per table-11 of ITU Rec. G.824 and figure 9/ ITU-T Rec. G.824.

6.13

Ethernet over SDH (EoS) interface The Ethernet services and implementation requirements have already been spelt out in clauses 6.2 and 6.3 in PART II of the GR. The equipment shall support Ethernet over SDH at 10/100BaseT, 100BaseFX@1310nm Fast Ethernet and 1000BaseSX (multi-mode) {optional}, 1000BaseLX & LH (both at 1310nm) Ethernet interfaces in accordance with ITU-T Rec. G.7041 (GFP-F) encapsulation. Ethernet tributaries (at electrical level) shall be terminated on Ethernet tributary cards or extended to IO cards after termination at common termination panel, using RJ-45 connectors with UTP Cat.5 cable or any other appropriate international standard cable. International industry optical connectors shall be provided for optical Ethernet ports. Type of connector Ethernet tributaries shall be terminated on Ethernet tributary cards using RJ-45 connectors with UTP Cat.5 or any other appropriate international standard cable for respective Ethernet interfaces, e.g., 10/100BaseT at electrical interface. The optical Ethernet connector shall be carrier-grade as per internationally industry standard. The Ethernet interface termination may be either provided directly on the IO cards at RJ-45/optical termination or may be terminated and extended to IO cards through backplane.

Note:

The exact nos. of 10/100BaseT, 100BaseFX, 1000BaseSX, 1000BaseLX and 1000BaseLH Ethernet interface cards shall be as per requirements of the purchaser.

6.13.1

Ethernet Adapters: (Optional) Ethernet Adapter shall be optionally provided for installation at Customer and Central office ends as per networking requirements.

- 63 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 64 -

Figure 5: Ethernet Adaptor


IEEE 10/100BaseT

Ethernet Adapter

IEEE 100Base FX To Central Office

The both side connectors and connecting patch-cords shall be the part of Ethernet Adapter.
# The purchaser may specify 10BaseT also.

6.13.2

Transparent SAN interfaces The payload and physical interface related requirements of Fibre Connection interface shall meet the requirements of ANSIX3.230 and the mapping of Fibre Connection payload shall transparently be done in accordance with ITU-T Rec. G.7041. The type of coding, alarms, error handling mechanism and payload integrity requirements shall be as per ITU-T Rec. G.7041.

6.13.2.1 Fibre Connection (FICON) interface

6.13.2.2 Enterprise Systems Connection (ESCON) interface


The payload related specifications of Enterprise Systems Connection (ESCON) SAN interface shall as per ANSIX3.296 and the mapping of the data shall be in accordance wit ITU-T Rec. G.7041. The type of coding, error-handling mechanism, alarms and payload integrity requirements shall be as per ITU-T Rec. G.7041.

6.13.2.3 Fibre Channel (FC) interface


The payload and physical interface related requirements of Fibre-Channel (FC) SAN interface shall meet the requirements of ANSIX3.230 and the mapping of the data shall be as per ITU-T Rec. G.7041. The type of coding, error-handling mechanism, alarms and payload integrity requirements shall be as per ITU-T Rec. G.7041.

6.13.2.4 Digital Video Broadcasting - Asynchronous Serial Interface (DVB-ASI) interface


The payload and physical interface related requirements of DVB-ASI interface requirements shall as per ANSIX3.230 the mapping of the data shall be as per ITU-T Rec. G.7041. The type of coding, error-handling mechanism, alarms and payload integrity requirements shall be as per ITU-T Rec. G.7041.

7.0

Mechanical standards
1. The equipment shall be housed in the standard sub-racks preferably 19'' width or ETSI standard rack. The sub-rack/chassis shall be fitted with motherboard duly masked to avoid short-circuiting. The sub-rack shall have protruded impressions on the top and base-plate of sub-rack assembly to act as built-in guides known as CNC guide forming for holding the PCBs in the sub-rack. The
- 64 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 65 -

back and forth movement of PCBs shall be very smooth without any significant play towards the sideways. 2. The guides in the sub-rack shall be made with CNC machines/tools. In case of CNC tool being used to make guides, in order to maintain the accuracy, the technique adopted shall use a single DIE punching. The plastic guides shall not be permitted. 3. In order to avoid bending/sagging of top and base-plates during transportation, installation and maintenance process, the metal-sheet used for these plates shall be minimum 1.2 mm in thickness for mild-steel material, 1.5 mm for Aluminium material and in case of stainless-steel material; the thickness of metal-sheet shall be 1.0 mm. 4. The connectors used on the PCB and their mating connectors on the motherboard shall have tight grip to avoid jacking problems. The connectors used shall be professional grade telecom connectors of international industry standards. (Euro-type or better). 5. The slots for interfaces in the sub-rack shall be universal, supporting any type of PCBs in any position ex cept for common control, matrix and line cards. No damage shall take place to PCBs when loaded in the wrong slot except in power-supply unit slots. The PCBs shall have the provision of locking/screwing to the sub-rack. 6. The input/output terminations of tributary signals shall either follow extended mother-board using connectorised connections or directly from proper connectors at the mother-board. 7. The termination of 2048 Kb/s signals in each case shall adopt wire-wrapping, IDC, D-type connectors. No soldering for connections shall be permitted. There shall be proper covers on the sub-racks/main-racks or similar arrangements to avoid the ingress of dust. 8. The height of main-rack shall be strictly as per this document till specified otherwise. The main-rack shall be made from metal-sheet of minimum 2.0 mm thickness and shall be covered from three-side minimum, with top and base covers. The thickness of the back -covers shall be 1.0 mm minimum. The base-plate of the main-rack shall be 2.0 mm minimum. 9. The main-rack shall have adequate provision of holding/fixing the sub-racks in their positions. It shall be ensured that there is no lateral movement of sub-

- 65 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 66 -

racks when fitted in main-rack. The main-rack shall have the proper fixing arrangements on floor, preferably with a base-plate and expansion-bolts etc. The thickness of base-plate shall be minimum 2.0 mm. The main-rack supplied with equipment shall be uniform in size irrespective of the loading of the equipment for all consignments by the manufacturer. 10. The manufacturer shall specify the mechanical standard of racks and sub-racks in their manual and shall maintain the size and standard of racks, sub-racks, connectors etc., during supply of the equipment. The main-rack shall have sufficient space preferably in the sideways for running the input out cabling etc. This shall specifically be ensured during the testing, field trial and QA of the equipment. 11. The permanent wiring such as distribution of power-supply and grounding etc. shall be pre-wired. During the testing and supply of the equipment the racks and sub-racks quality supplied by the manufacturer shall be ensured. 12. The front opening of the sub-rack/main-rack is envisaged. No rear-side/sideway opening shall be permitted. The access to data terminations shall be from the front side only.

8.0

Minimum equipment for testing


One complete wired set of equipment with all functionalities as outlined in the GR with equipped traffic interfaces [as follows in this clause] in a wired-rack for full capacity of the equipment shall be offered for testing. An EMS/LCT loaded with software along with test jigs and test & measurement instruments shall also be offered to facilitate the testing.
Full-wired rack STM-16 interfaces STM-4 interfaces STM-1e, o interfaces 2Mbps interfaces 34/DS-3 interfaces 10/100BaseT interfaces 100BaseFX @1310nm interfaces 1000BaseSX* interfaces 1000BaseLX @1310nm interfaces 1000BaseLH @1310nm interfaces EMS LCT Test jigs, instruments & instrumentation
* optional to purchasers requirements.

- 66 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 67 Interfaces to be offered for testing Minimum 3 ADM nodes shall be offered for TAC testing with the loaded interfaces as followsSTM-64 interfaces STM-16 interfaces STM-4 interfaces STM1o interfaces STM-1e interfaces E1 tributary interfaces E3/DS3 tributary interfaces Ethernet 10/100BaseT interfaces Ethernet 100BaseFX at 1310nm 1000BaseSX*interfaces 1000BaseLX at 1310nm interfaces 1000BaseLH at 1310mn interfaces 2 nos. 4 nos. 20 no. 48 nos. 16 nos. 63 nos. 3 nos. 32 nos. 32 nos. 2 nos. 2 nos. 2 nos.

Note:

Each unit in above description infers a module providing one interface each for both directions of traffic.

9.0

Field Trial
The equipment shall be subjected to field-trial for a minimum of 4 weeks with working traffic. The equipment shall be loaded with maximum possible live-traffic for the entire system capacity & the balance with simulated traffic to assess the performance of the equipment.
_______________

- 67 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 68 -

ANNEXURE I ITU-T Parametric Tables

- 68 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 69 -

Tx
40 Kms.

Rx

Figure 1 Schematic diagram for a STM-64 short-haul link.

- 69 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 70 Table 1/G.691 - Parameters for STM-64 optical interfaces Unit Transmitter at reference point MPLS Operating wavelength range Mean launched power -maximum -minimum Spectral characteristics -maximum-20dB width -chirp parameter , -maximum spectral power density -minimum SMSR Minimum EX Main optical path, MPI-S to MPI-R Attenuation range -maximum -minimum Chromatic dispersion -maximum -minimum Passive dispersion compensation -maximum -minimum Maximum DGD Min ORL of cable plant at MPI-S, including any Connectors Maximum discrete reflectance between MPI-S and MPI-R Receiver at reference point MPI-R Minimum sensitivity (BER of 1*10-12) Minimum overload Maximum optical path penalty Maximum reflectance of receiver, measured at MPI-R dBm dBm dB dB -18 -8 2 -27 -17 -8 1 -27 dB dB ps/nm ps/nm ps/nm ps/nm ps dB dB 11 7 800 700 0 0 30 24 -27 11 3 130 110 0 0 30 24 -27 nm 1530 1565 -1 -5 0.1 * * 30 8.2 1530 1565 -1 -5 0.1 * * 30 8.2 S64.2a S-64.5a

dBm dBm nm Rad mw/MHz dB dB

- 70 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 71 Table 2 Parameters specified for STM-16 optical interfaces ITU-T/G.957


Unit Digital signal Nominal bit rate Application code (Table 1) Operating wavelength range Transmitter at reference point S Source type Spectral characteristics: maximum RMS width () maximum 20 Db width minimum side mode suppression ratio Mean launched power: maximum minimum Minimum extinction ratio Optical path between S and R Attenuation rangec) Maximum dispersion Minimum optical return loss of cable plant at S, including any connectors Maximum discrete reflectance Between S and R Receiver at reference point R Minimum sensitivityc) Minimum overload Maximum optical path penalty Maximum reflectance of receiver, measured at R dBm dBm dB dB dB dB ps/nm dB 0-7 12 24 0-12 NA 24 0-12
b)

Values STM-16 according to Recommendation G.707

kbit/s I-16 nm 1266 a) -1360 S-16.1 1260 a) -1360 S-16.2

2 488 320 L-16.1 1280-1335 L-16.2 1500-1580 L-16.3 1500-1580

1430-1580

MLM

SLM

SLM

SLM

SLM

SLM

nm nm dB

1 30

1 30

< 1b)
30

< 1b)
30

< 1b)
30

dBm dBm dB

3 10
8.2

+3 2
8.2

+3 2
8.2

+3 2
8.2

5
8.2

5
8.2

10-24e) NA 24

10-24e) 1200-1600b),d) 24

10-24e)
b)

24

24

27

27

27

27

27

27

18 3
1

18
0 1

18
0 1

27 9
1

28 9
2

27 9
1

27

27

27

27

27

27

- 71 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 72 -

table 4/G.957 / ----contd. a) b) c) d)

Some Administrations may require a limit of 1270 nm. See 6.2.2. See clause 6. The indicated dispersion range corresponds to the approximate worst-case dispersion for 80 km G.652/G.654 fibre over the

wavelength range 1500-1580 nm: manufacturers shall ensure sufficient margins to guarantee proper operation over a target distance of 80 kms.
e)

To meet 10 dB minimum attenuation instead of 12 dB, it will be required to decrease the maximum output power, to increase the

minimum overload, to use optical attenuators, or a combination thereof.

- 72 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 73 Table-3 [Parameters specified for STM-4 optical interfaces] ITU-T G.957


Unit Digital signal Nominal bit rate Application code (Table 1) Operating wavelength range Transmitter at reference point S Source type Spectral characteristics: maximum RMS width () maximum 20 Db width minimum side mode suppression ratio Mean launched power: maximum minimum Minimum extinction ratio Optical path between S and R Attenuation rangec) Maximum dispersion Minimum optical return loss of cable plant at S, including any connectors Maximum discrete reflectance between S and R Receiver at reference point R Minimum sensitivityc) MLM nm nm dB 14.5 LED 35 MLM 4/2.5 SLM 1 30 MLM 2.0/1.7 SLM 1 30 SLM < 1 b) 30 SLM 1 30 kb/s I-4 1261 a) -1360 Values STM-4 according to Recommendation G.707 622 080 S-4.1 S-4.2 L-4.1 1293-1334 / 1274-1356 14301580 13001325/ 1296-1330 12801335

L-4.2 14801580

L-4.3 14801580

nm

dBm dBm dB

8 15 8.2

8 15 8.2

8 15 8.2

+2 3 10

+2 3 10

+2 3 10

dB Ps/n m dB

0-7 13 NA 14

0-12 46/74 NA

0-12 NA 24 27

10-24 92/109 NA 20 25

10-24
b)

10-24 NA 20 25

24 27

dB

NA

NA

dBm

23

28

28 8 1 27

28 8 1 14

28 8 1 27

28 8 1 14

Minimum overload dBm 8 8 Maximum optical path dB 1 1 penalty Maximum reflectance of dB NA NA receiver, measured at R a) Some Administrations may require a limit of 1270 nm. b) See 6.2.2 c) See clause 6.

- 73 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 74 Table- 4 [Parameters specified for STM-1 optical interfaces]


Unit Digital signal Nominal bit rate kb/s Application code (Table 1) Operating nm wavelength range Transmitter at reference point S Source type Spectral characteristics: maximum RMS nm width () nm maximum 20 dB width minimum side dB mode suppression ratio Mean launched power: maximum dBm minimum dBm Minimum dB extinction ratio Optical path between S and R Attenuation rangeb) dB Maximum ps/nm dispersion Minimum optical return loss of cable plant at S, dB including any connectors Maximum discrete dB reflectance between S and R Receiver at reference point R Minimum dBm sensitivity b) Values STM-1 according to Recommendation G.707 155 520 I-1 1260 a) -1360 S-1.1 1261 a) 1360 S-1.2 14301576 14301580 L-1.1 1263 a) -1360 L-1.2 14801580 L-1.3 1534-1566/ 1523-1577 14801580

MLM

LED

MLM

MLM

SLM

MLM

SLM

SLM

MLM

SLM

40

80

7.7

2.5

1 30

1 30

1 30

3/2.5

1 30

8 15 8.2

8 15 8.2

8 15 8.2

0 5 10

0 5 10

0 5 10

0-7 18 25

0-12 96

0-12 296 NA

10-28 246 NA

10-28 NA

10-28 246/296 NA

NA

NA

NA

NA

20

NA

NA

NA

NA

NA

25

NA

23

28

28 8 1 NA

34 10 1 NA

34 10 1 25

34 10 1 NA

Minimum overload dBm 8 8 Maximum optical dB 1 1 path penalty Maximum dB NA NA reflectance of receiver, measured at R a) Some Administrations may require a limit of 1270 nm. b) See clause 6.

- 74 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 75 -

ANNEXURE II Ordering Instructions

- 75 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 76 -

Part I: General Requirements Clause 1.1 Clause 1.13 Clause 1.14 Specify choice for ADM or TM. Specify requirements, if any, for VC3 based VCGs. Specify Ethernet/SAN interface option.

Part II: Technical Requirements Clause 1.5.1 Clause 4.1.1 Clause 4.4.1 Clause 6.2.4.1 Specify application codes requirements for line and tributary interfaces. Specify Ethernet interfaces choice. Specify Inherent SNC protection requirements. The system shall provide optional capability for translation of a contiguous concatenated payload in to a VCG (and vice-versa). The choice may be conveyed, if required. Clause 6.3.2 The VCG selection shall either be autonomous based on VLAN-ID, MAC based, port based which shall be configured through EMS & LCT or it may also be pre-configured through EMS. The purchaser shall convey exact requirements. Clause 6.14.1 Clause 5.1.8 Ethernet media converter requirements may be spelt out. Specify Tributary Interface re-timing option.

Appendix I: EMS Requirements Clause 2.1 The purchaser shall communicate requirements for (1+1) server backup or internal constituents of server. Appendix II: VLAN Administration The purchaser shall communicate VLAN scalability requirements depending upon the deployed network size.

- 76 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 77 -

APPENDIX I EMS Requirements

- 77 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 78 -

APPENDIX I - Part I
1.0 General Operational & Functional Requirements 1. The EMS shall be multi-user system and based on Graphical User Interface. 2. It should be possible to generate customized reports for various types of faults, performance history, security management etc. It should also be possible to generate up time-reports at 2Mbps, 34Mbps, DS-3, Ethernet, STM-1, STM-4, STM-16, STM-64 and SAN interfaces (as applicable) to facilitate monitoring of performance statistics in a pre-defined/customized format. It shall be possible to generate and define the formats at any time, based on network needs. 3. It should be possible to have a view of selected sub-networks/rings controlled by the Element Management System as per requirement. By zooming-in, it shall be possible to drill down up to module-level in each NE for configuration and fault management. The same shall be provided through user-friendly GUI commands. 4. The EMS shall be able to diagnose its own faults by running diagnostic software. 5. The Element Manager shall provide the complete view of the network elements and the interconnecting links. The EMS shall have the ability to include the network elements and the links in the visual/graphical map of the domain. The visual maps shall display the elements and the links in different colour depending upon the status of the links. It is preferable that green colour for healthy and amber/yellow colour f r degraded condition and red for o unhealthy condition is used. 6. It shall provide the ability to drill down to the individual element, then to subsystem, then to card and then to port level configuration template from the domain-map by clicking on the icon of the network element. 7. The Element Manager shall have suitable system level backup mechanism for taking backup of EMS data of at least one month. There shall be no magnetic tapes used for the objective, only DVD, CD-ROM shall be provided. 8. The information model shall be as per specified standards. The EMS shall support correlation (filtering and suppression) to avoid multiple alarms from a single source of failure within the sub-network. Single Alarm shall be provided for the events that are correlated and are due to a common cause. 9. The EMS shall provide the visual presentation of the Network Elements status and the alarms. It shall also present the complete map of the network domain with suitable icons and in suitable colour like green for healthy, red for non-operational, yellow for degraded mode of operation etc. 10. It shall be possible to take any Network Element out-of-service & in-service from the EMS. It shall be possible to restart the Network Element from EMS. 11. The EMS shall carry out the systematic Health Monitoring of the elements of the Network. Check on the health of the card of any element of the Network shall be possible through command with settable periodicity - @ 24 Hrs, 1 week, 1 month. 12. It shall be possible to log recent commands and be re-displayed, and re-issued on request through GUI.

- 78 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 79 -

13. The configuration of the various network elements like creating, viewing, and editing shall be possible from the EMS. The configurations of the network elements shall also be stored at suitable place in EMS from where it can be retrieved in case of failure. 14. It shall provide the graphical layout of the network elements with modules drawn using different colours to indicate their status. 15. Manufacturer shall provide soft copy of his EMS on a CD on per-ink or per-ring basis (or as asked for by the purchaser). The setup/procedure to download the software shall be clearly mentioned in the system manual of the equipment. 16. Calendar Management It shall be possible to execute any schedulable administrative command i e.- NE backup, . software download, performance, operator log-in/ log-out etc., at any time by attaching a time tag to the command and it shall be executed when the Network real time matches the time tag. It shall be possible to define both time and date. If no date is mentioned, the command shall be executed daily at the time indicated. 17. Messaging system The EMS shall have a messaging system which will generate and send alert messages on telephone (fixed & mobile), e-mail or SMS to the designated personnel depending upon the location of NE, on generation of alarms.. 18. It is recommended that the response time for query/command on any operator terminal, local or remote shall be 10 seconds or better. For updation on topological information on the terminals, the response time shall be better than 20 seconds under all conditions. The response time shall however, be reviewed depending upon total NE load and topology by purchaser during testing of EMS. 19. The supplier shall provide all necessary interface details (with the documents) for integration of its EMS with existing or proposed NMS (irrespective of its brand/make) and also provide time bound support for its integration, under obligation of a Non-Disclosure Agreement (NDA). 20. The supplier shall provide infrastructure requirements to the purchasers for setting up the EMS. The items of infrastructure include A/C power, Air conditioning load, space etc. 21. All critical components and units of the EMS i.e. LAN interfaces, hard-disk, processor etc., shall be fault resilient. 22. It shall be possible to produce customized reports. The purchaser shall be free to ask for customization of reports based on the data available in the database from time to time. 23. It shall be desirable to interconnect a Disaster Recovery EMS with an existing EMS, in future, with possible manual switchover between them. The issues regarding hardware and software compatibility with regards to existing server platform shall be subject to a mutual understanding on the issue between purchaser and manufacturer. 24. Installation & commissioning of the EMS shall include supply & installation of cables, distribution frames, electrical switches etc. 25. Format for creation of database of rings, network elements, circuits, ADM/DXC/TMs etc., and their numbering scheme, details of built up points across various rings other commissioning details, supplementary information, order reference, dates etc. shall be prescribed by purchaser at the time of validation of EMS.

- 79 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 80 -

26. The purchaser shall validate all the components of EMS a features of EMS. All the nd instruments necessary foe carrying out validation test shall be arranged by supplier. 2.0 2.1 EMS Architecture & Server Specifications Architecture 1. It shall be ensured that EMS connectivity to sub-network is not disrupted and there is no loss of EMS performance and fault data from the sub-network. To ensure EMS connectivity to the sub-network under control-card failure, there shall be provision to support dual-homed connectivity of EMS to two Gateway NEs (GNEs) in a sub-network. The performance and fault data for the sub-network shall be available even if the master control-card at one GNE fails. In case of total loss of EMS connectivity, the sub-network shall continue to provide the services without any deterioration. 2. In case of total loss of EMS connectivity, it is recommended that the performance data of the NE shall be stored in the controller card, and shall be sent to central EMS server upon restoration of EMS connectivity. it is recommended that 6400 performance and fault data messages containing a minimum of 100 alarms shall be stored by the system. The response time shall however, be reviewed depending upon total NE load and topology by purchaser during testing of EMS. 3. In case of loss of EMS connectivity, the LCT privilege shall remain for monitoring and for local configurations, as privileged by EMS administrator. 4. The centralized EMS may consist of standalone application server, database server and firewall server or it can be a standalone EMS server subject to scaling requirements. Any other server required for meeting the purchase requirements shall be quoted separately by the bidder. 5. LCT connectivity to EMS for privileged operation shall be through a log-in password. 6. As a cost effective measure, two display units are adequate for all the servers (application, database, and firewall servers). Purchaser is at discretion to convey any additional requirements. It shall be possible to access any server from any of the display. 7. The purchaser shall communicate requirements for (1+1) server backup or internal constituents of server. 2.2 1. 2. Scalability Aspects The EMS should be able to support at least 1000 NEs. The EMS application shall also be scaleable to 1000 NEs. Any more requirements may be communicated by purchaser. Operating system and applications for EMS including database server shall be multi-user with minimum 25 concurrent users (including local terminals at EMS site and remote terminals i.e. LCTs). Any more requirements may be communicated by purchaser. A minimum of four operator terminals will be provided at the EMS site. The EMS shall be equipped to connect to at least 10 local terminals at EMS site. It shall be upgradeable to 25 local terminals. The operator terminals at the EMS site are recommended to be PC Pentium IV with 80 GB HDD, 17 video display, Ethernet interface (10/100 Mbps) with industry standard operating system UNIX/Windows but having GUI.

3.

- 80 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 81 -

2.3

EMS Server Specifications A Telecom Grade Enterprise Server from a reputed national/international vendor with broad specifications, as below, shall be provided at a minimum: The multi-process EMS design is recommended which shall enable distribution of functions over multiple processors. In addition, the RMI inter-process communication enables distribution of functions over multiple servers. Consequently, increasing system capability can be achieved by upgrading the existing platform (e.g. adding CPUs) or adding new servers into the cluster. The manufacturer shall indicate limitations regarding processing requests, notifications, updates, Network-map view refreshing etc., in the supplied system. Both Application and Database servers shall have UNIX based operating system. The EMS shall be supplied with a Work Station offering Graphical User Interface (GUI) using 17 colour screen with key board and Mouse etc. The Work Station shall be of latest type of machine with very high processing speed as available on the date of procurement of equipment. The Work Station shall support Ethernet ports as 10BaseT, 100BaseT. The operating system shall be Windows 2000 or XP. The specifications are given in clause 2.7 of the Appendix I.

2.4

Application Server Specifications The EMS application server shall multi-server based (with at least the two servers [1+1] to begin with), with each server having multi-processor (at least 2 processor), at least 1.5 GHz clock, 8 GB RAM, 512 KB cache memory, 80 GB HDD with CD-ROM/DVD-ROM, Ethernet LAN interfaces floppy drive, and shall operate in high availability cluster mode. However, the purchaser may choose single server as per network needs. Exact specifications may be issued by purchaser.

2.5

Database Server Specifications The database server shall be multi-server based (desired with 2 servers for redundancy) each with 4 processors and expandable to minimum 8 processors, RISC based 64 bit system with at least 1.5 GHz clock, 8 GB RAM and one GB Cache memory. However, the purchaser may choose single server as per network needs. The system disc shall be 80 GB with OS and RDBMS mirroring 20/40 GB DAT drives shall be provided as back up devices. The system shall support at least 6X DVD for loading of software and configuration. The system shall have Hard-disk storage implemented on RAID 0, RAID 1, RAID 0+1 and RAID 5 architecture of Disk Storage which shall be site configurable. The RAID system shall be hardware based and shall have redundant Fibre based RAID controller. The Hard-Disk storage shall provide for no single point of failure. The server will operate in high availability cluster mode, on load sharing basis. Any alternate specifications may be issued by purchaser. 1. Database hard-disk memory shall be sufficient to store all the information as indicated in the document and any other necessary system for at least one month duration. 2. Each of the server i.e. EMS server and database server as well as firewall server shall have redundancy for control module, disk, power supply and LAN interface. 3. Industry standard relational database (RDBMS) for storing all the data related to the network and the system shall be used. 4. The database interface shall be open so that a centralized EMS at a future date is able to retrieve information from the EMS database using TCP/IP stack and do post processing. The data base structure for all the databases used in the system shall be provided. - 81 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 82 -

5. The memory of the Database Server shall be sufficient to store the data of 1000 fully loaded equipment nodes (as per respective type/category of equipment) at a minimum. It shall be capable of storing performance/ fault history of 30 days of the network under its domain. This shall be ensured during the testing of the equipment. 2.6 Firewall Server [optional requirement] In order to provide security to EMS from public networks, adual redundant hardware based Firewall system may be provided at each of the NMS locations for providing security to the various servers at the EMS. The Firewall System shall be as per TEC GR No.: GR/FWS-01. The Firewall System (FWS) shall have a capability of handling a concurrent sessions of around 20,000. The Firewall System shall support 4 ports of 10/100BaseT expandable to 12 ports. There shall be a common Firewall System. The firewall system shall be used for providing the security cover to the Web Based Customer Care System from the internet. The same Firewall system shall also provide the security to the EMS Database from the Internet and the Web Based Customer Care Users & the Systems. The firewall shall be based on stateful connection-oriented firewalling and shall be appliance/hardware based. The firewall shall track the following parameters of each packet-source and destination address, Transmission Control Protocol (TCP) sequence numbers, port numbers and TCP flags.

2.7

Specifications for Local Crafts Terminal/Client Terminal/Work Station The LCT desktop configuration as a PC or Laptop shall be as given below at a minimum Pentium IV 2 GHz and above 17 Colour Monitor (for PC) and LCD/TFT display (for Laptop) 40GB/256 MB RAM 48X CD-ROM drive 1.44 MB floppy drive LAN port Inbuilt Modem 2 Nos. USB Ports Printer port Mouse port PS-2 Keyboard port Licensed Operating software preloaded/Recovery CDs.

The Desktop/Laptop shall be supplied with the LCT software installed in it. The PC shall be from a reputed international/national PC manufacturer. Note: No QM-333 environmental tests shall be conducted on the EMS Server/LCT PC.

- 82 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 83 -

APPENDIX I - Part II

FCAPS TEMPLATE FOR SDH TRASNMISION PRODUCTS


1.0 1.1 Network Management Functions General Functions The equipment EMS shall provide general management functions described in ITU-T Rec. G.784. The filters for performance and fault management shall also be as per ITU-T Rec. G.784. The other management functions as defined in ITU-T Rec. G.784 shall be as under: 1. 2. 3. 4. 5. 6. Configuration Management Fault Management Performance Management Security Management Software Management Inventory Management.

FCAPS shall be evaluated in terms of the circuits/connections which shall be identifiable in terms of ADM/TM/DXC based on addressing mechanism. 2.0 Configuration Management The equipment EMS shall support configuration and provisioning capabilities as per ITU-T Recs. G.783 and G.784. The system shall support Point & Click provisioning in a vendors subnetwork, subject to clearance by Inventory Management, shall be supported as per the following configuration provisioning: 1. To partition the network as defined in ITU-T Rec. G.803 on request and control either in full or with limited network resources. 2. Network Element creation in the NE Management domain. 3. Programming of a multiple interface unit. 4. To create, update, delete and retrieve the managed network topology data. 5. Assigning the equipment protection to a unit/interface. 6. Selection of protection switching within the managed network and protection switching granularity. 7. Matrix connections. 8. Error detection thresholds. 9. Network Element configuration. 10. Software download (local & remote). 11. Protection switching enabling/disabling for individual traffic interface at virtual containers, i.e., VC4. 12. Ethernet/SAN interface bandwidth through VCAT and MAC configurations 13. Enabling/disabling of LCAS 14. Enabling/disabling of FEC (if implemented) 15. DCC multiple management configurations 16. Configuration related to multiple management options etc.

- 83 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 84 -

3.0

Fault Management The equipment management system shall support Fault Management Functions as described in the ITU-T Rec. G.784. The Equipment Management Function within the Network Element shall perform a persistency check on the fault-cause, before it declares a fault causing failure. The time taken to declare the fault shall be as per ITU-T Rec. G.784. Each failure and clearance, thereof, shall be time-stamped. The atomic functions associated with the failure shall be as per ITU-T Rec. G.784. The equipment shall do surveillance of alarms & their detection, reporting of relevant events and conditions that lead to the generation of alarm after filtering. The system shall support the alarm history as per ITU-T Rec. G.784. Further, the element management system shall support the following: 1. Path alarm notification to be generated and recorded, the alarm notification shall include: type, occurrence, severity, probable cause and clearing. 2. Path alarm shall be graphically shown by the EMS/LCT. 3. Alarm and status display. 4. Fault localization. 5. Fault correlation control. 6. Storing and processing of current alarm information, up to module/unit level. 7. Storing and processing of historical alarm information for 30 days minimum. The EMS/LCT shall provide on-line logging capability for historical alarms and events with sufficient information such as managed resources, alarm/event type, alarm severity, day and time of occurrence etc. The retrieving functions with filtering capabilities for historical alarms and events shall be provided as well. 8. FCS errors for Ethernet clients. 9. Assigning alarm severity i.e., Critical, Major, Minor & Deferred.

4.0

Performance Management The equipment shall support the Performance Management functions in accordance with ITUT Rec. G.784. The performance management shall consist of set of functions that evaluate and report on the behaviour of network element and their effectiveness relating to the communication taking place on the network. The performance management shall deal with definitions, evaluation and reporting of equipment performance. It shall be possible to store all the performance and traffic statistics for a month. It shall also be possible to generate daily, weekly, monthly reports for the individual element as well as complete domain. The report generation shall be supported for text and graphic reports. These functions shall be implemented using information flows at the reference points S1 & S2 and filtering functions as described in ITU-T Rec. G.783. The performance monitoring shall conform to ITU-T Recs. M.2100, M.2101, M.2120, G.821, G.826, G.828 and G.829. The near-end performance monitoring, far-end performance monitoring, performance data collection and performance history shall be as per ITU-T Rec. G.784. Performance history for minimum 30 days shall be supported with configurable launch-time and performance evaluation/integration period. The main performance functionality to be provided shall be as under: Configuration of threshold concerning the error counters. Performance reporting and monitoring. Performance history (data logging) The EMS shall store the performance data of the sub-network in terms of configured circuits. In addition to, the following shall also be some of the different parameters that shall be stored -

- 84 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 85 -

The collection of the performance counters shall be performed at pre-assigned rate as per ITU-T Rec. G.784. The EMS shall support configurable scheduling of the performance measurement, collection, storage and transfer of the performance statistics. It shall also support presentation of the performance statistics in graphical and text mode as and when requested and at repeated interval automatically.

5.0

Security Management The management system shall provide adequate security to the data and for the access to the management system as per the following details: 1. The EMS shall have the capability of supporting the management of Network through local and remote Operators. The authorizations and the privileges of the operators (Remote and Local) shall depend upon the Login and Password. a. Low level protection for read only access to faults and performance information. b. Medium level protection for access to configuration status and features. c. High level protection for control of access to change in the configuration and control parameters. 2. Network management security features shall include operator authentication, command, menu-restriction and operator privileges. The EMS shall support multi-level passwords as belowa. EMS shall allow the System Administrator to define the level of access to the network capabilities or feature for each assigned password. It shall be desirable that the EMS shall block the access to the operator in case of unauthorized commands being tried for five consecutive times. Also it is desirable that the EMS shall also not allow the entry into the EMS in case wrong password is provided more than five consecutive times during the login. b. The system administrator shall be able to monitor and log all operator activities in the EMS and Local Craft Terminal. c. The dynamic password facility shall be provided in which the operator may change his password at any time. 3. All log-in and log-out attempts shall be logged in the security log file of the EMS system. 4. The network and the management system shall be protected against intentional or accidental abuse, unauthorized access and loss of communication. 5. The man-machine communication programs shall have the facility of restricting the use of certain commands or procedures to certain passwords and terminals. 6. The LCTs shall normally operate through the centralized EMS. Only in the case of failure of link between the LCT location and the EMS, the LCT should be able to supervise/monitor the local assigned to it. 7. It should be mandatory for the system to have a record of all log-ins for a period of at least six months after which a back up should be possible under system administrator command. 8. It shall be possible to connect EMS and the network elements to the IP-MPLS network. The EMS and components of the existing/proposed Network Management layer (NML)/Service Management Layer (SML) of a purchaser shall be part of the common MPLS-VPN providing the inherent security required for the Management information in addition to the login and Password based authorization for the operators of the Network Manager. 9. Back up for programmes and data.

- 85 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 86 -

10. The EMS shall be able to back up and restore the data base to and from external storage media; 11. External Security Measures {Optional Requirements} Network security may require deployment of external devices/machines/ firm-ware at the network operation centre [NOC], likefirewalls access control servers 3. data encryption devices/use of PKI keys 4. anti-virus packages. 5. in the data communication network (DCN) for management system, VLAN tags/MPLS labels may be used for security to information flows from Gateway NEs (GNEs) to DCN Gateways with IPSec, PKI security options.
1. 2.

The purchaser may communicate requirements as per his network security needs. 6.0 Inventory management 1. It shall indicate the absence or presence of any physical module in hardware elements. It shall also indicate the usage of module i.e. how many ports are in use, which interface is in use and which are free to be used etc. 2. The EMS shall be able to discover and keep the device information 3. The EMS shall be able to keep track on any change in the network inventory reported chronologically. 4. The EMS shall provide the inventory information to the Network Management layer (NML)/Service Management Layer (SML) so that SML is able to create and activate a service to the customer automatically. This shall also assist SML in providing the network inventory to which the SML shall add the customer identification and maintain this information in its database. 5. The EML shall be able to show inventory based on the available device inventory in terms of circuits utilization. 6. The EMS shall provide the complete view of the network elements and the interconnecting links. 7.0 Software Management It shall be possible to carry out the following tasks under the software management function: 1. Loading of new system software. 2. Manage different versions of software. 3. Shall have the capability of managing multiple versions of software for individual elements. In this case, one software version shall remain active and other versions shall be passive. 4. Installation of software patches. 5. Examine contents of all system memory and disk memory. 6. At the time of downloading the software, the message shall be displayed that the software has been downloaded successfully or failed and at what stage. 7. The EMS shall support FTP/TFTP for downloading of Software, configuration, patches etc., to the Network Element. 8. The operator terminals (local & remote) shall not allow loading of any software without the terminal administrators authorization.

- 86 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 87 -

9. The EMS shall enable operations like changing the system configuration, reconfiguration of input and output devices, loading a new software package, etc. Both automatic and manual reconfiguration capabilities shall be available. 10. All commands which are executed over the EMS program or data shall be logged in a file (read only) and it shall be possible to retrieve the same on demand whenever required, using Man-Machine Commands. The file usage of up to 50%, 75% and 90% shall generate alerts in the server platform, of suitable category prompting the operator to initiate the backup operation. 11. It shall be possible through a single Man-Machine Command to obtain a list and the total number of equipment of a particular domain in a state (e.g. in-service, blocked etc.). 12. While working on system level commends, it shall be possible to store at least the last 20 commands on the screen and by scrolling and editing any command shall be re-executable. 7.1 Software Download Local & remote software download via management system to NEs and LCT shall be possible, including the means of identification of software module versions. No loss of data/traffic & connection-map shall take place during the software down-loading process. Management Interface The complete details of the management interface and the protocols, as pertaining to each layer of the protocol-stack implemented in the management system, shall be made available, for the purpose of integrating the local management capabilities with the centralized NMS at a later date. The requirements, in brief, shall be: 8.1 Protocol details at all layers of TCP/IP stack. PHY I/F at each layer. Database structures. Number formats. Node addressing system. Complete application software details etc. EMS software check-sum.

8.0

Southbound Interface The system shall provide at least one remote management interface and one Local Management Interface at each Network Element as conforming to ITU-T Rec. G.773. The system shall provide an SNMP version2c [or later interface] with standard MIBs Browzer. It shall be implemented on UDP/IP stack at all Gateway NEs (GNEs) to interact with a centralized Element Management System (EMS). Or else ITU-T specified Qx or Bellcore specified TL1 interface implemented on TCP/IP, remote management interface shall also be acceptable.

Note 1:

The equipment shall provide an Ethernet port for Work Station/Network Server connectivity with standard RJ-45 connector. The purchaser may validate vendors claim for management functions as well as protocol compliance for Qx or SNMPv2c interface (or later interface) through NMS Protocol Analyzer etc. Northbound Interface For remote management purposes, the equipment shall provide remote and local management interfaces at NEs as outlined in the GR. The northbound interface of the EMS towards NMS layer shall be TMF 814 CORBA [version 3.0].

Note 2:

8.2

- 87 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 88 -

And the southbound interface towards NEs shall be SNMPv2c [or later interface] implemented on UDP/IP stack. The purchaser may verify SNMP MIBs and CORBA IDLs during their testing. 8.3 Local Management Interface The manufacturer shall provide a Work Station/Network Server, which shall act as a manager of management activities, i.e. monitoring and controlling NEs within its management domain. The Local Craft Terminal i.e., a Personal Computer shall support the local management of NEs. The Local Craft Terminal and Network Server shall be operating simultaneously. The interoffice communication shall be facilitated through DCC channels or dedicated datalink. The equipment shall provide V.24/V.28/RS232/RS-485 for connecting a PC-server as a Local Craft Terminal. 8.4 User Interface The management system shall be provided with user-friendly interfaces based on Windows/UNIX icons & menus and mouse to accomplish management function that needs user interventions. The EMS start-up and shut-down shall be user friendly, and shall provide online help. The EMS shall be able to provide an on-screen nested geographical view of the managed network in the management domain of the manufacturer. It shall be possible to access any managed node with in the whole network in the managed domain. The EMS shall be able to depict the failure state of each link and node in the displayed network. Further, it shall also be possible from the EMS system to get the details of status of an individual managed NE, such as equipment presence, settings, alarm status etc. 9.0 Embedded Control Channel Twelve bytes D1 to D12 shall be used for Embedded Control Channel (ECC) protocol stack in accordance with the ITU-T Rec. G.784. There shall be additional requirement for multiple management options using DCC channels as outlined in the following clause. 10.0 Multiple Management Options The equipment shall support Embedded Control Channels (ECC) transported over DCC bytes viz., D1 to D12 to be used for transfer of management information, in accordance with ITU-T Rec. G.784. Each of STM-N (whether it is line or tributary) shall have accompanying ECC. The equipment shall provide handling of all the ECC/DCC from/to all STM-N interfaces. The flow of protocols between the Work Station/Server and SDH equipment NE to NE shall strictly flow through Embedded Control Channels D1 to D12 with additional functionalities as below D1-D3 bytes of RSOH - DCCr D4-D12 bytes of MSOH - DCCm The configuration for the above shall be provided through EMS. It shall be possible to allow DCC bytes which are unused by the equipment to flow transparently through the equipment. It shall be possible to map/retrieve DCC information to/from D1-D3 and D4-D12, local Ethernet Qx/SNMP management port, embedded VC12 in STM-N ports or physical E1 ports at local end. It shall be possible to transparently pass through D1-D3 and D4-D12. This is

- 88 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 89 -

required for allo cation of one of the sets to IP or OSI-DCC. Otherwise dual stack IP/OSI DCC shall be provided. It shall be possible to allow DCC bytes which are unused by the equipment to flow transparently through the equipment. The equipment shall provide multiple management options, in addition to the conventional use of DCC bytes, to allow greater scope for inter-vendor interoperability and simplification of operation, administration & management of the network. The following options shall be provided in the equipment for physical access to the DCC information on STM-N line1. 2. 3. 4. Tunnelling DCC in to assigned VC-12 embedded in outgoing STM-N line frame or, Termination of DCC at E1 interface/s as part of an external DCN or Termination at Ethernet traffic interface/s as part of an external DCN. Termination at remote management interface at Gateway NEs (GNEs) on Ethernet interface.

Or else, the equipment shall provide dual IP or OSI DCC routing stack in accordance with ITUT Rec. G.7712. In such cases, configuration of DDCr (D1-D3) and DCCm (D4-D12) shall be provided as either IP-DCC or OSI-DCC through EMS. The equipment shall provide in-built intelligence to auto-sense as to which DCC block is relevant to it. The other DCC block shall be transparently tunnelled across, either at physical layer through one (and more VC12) or routed through IP/OSI stack. Termination of DCC at Qx/SNMP/TL-1 remote management interface at GNE #1 & 2 at Ethernet interface/s shall essentially be provided. Regarding tributary STM-1/4/16 DCC termination, the system shall provide physical layer transparent tunnelling of DCC information across desired STM-N aggregate lines. 11.0 Extending DCC to central EMS Sever The ports and the bandwidth requirements for DCC connectivity to an IP/MPLS network for extending the connectivity of network elements to the centralized EMS shall be indicated by manufacturer to the purchaser. Bandwidth requirement per NE/EMS shall also be specifically indicated by the manufacturer. 12.0 List of Constituents for a DCN Dual-stack (IP and OSI) Routers LAN Switches Interface converters between Ethernet/E1 G.703 Ethernet adaptors 100BaseFX @1310nm 12.1 Specifications Broad specifications of LAN Switch and Routers are outlined in the following, whereas the purchaser is at discretion to issue alternate specifications as per networking needs. 12.1.1 LAN Switch LAN switches may be used to terminate Ethernet interfaces from NEs at a transmission centre and to aggregate at uplink WAN ports towards a router. The LAN switch shall provide 10BaseT or Fast Ethernet interfaces towards NEs. The LAN switch for DCN shall be middle range LAN The quantity shall be conveyed by purchaser. The quantity shall be conveyed by purchaser. The quantity shall be conveyed by purchaser. The quantity shall be conveyed by purchaser.

- 89 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 90 -

switch as per TEC GR No.: G/LSW-01/01.JUN.2000. The middle range LAN switch (LAN SWITCH-1) may be used in case 16 ports supporting 10/100 Mbps is the requirement. Similarly, LAN switches may also be used at EMS location for connecting various servers, firewalls etc. The exact network design and architecture for a DCN is out of scope for this document. 12.1.2 Router A router may be required to interconnect various transmission centres in a city and finally to connect to an IP/MPLS network for providing regional/national connectivity over MPLS-VPNs. In order to integrate existing NEs based on OSI management model, the router shall provide dual-stack (IP+OSI) i.e. - CLNP for Q3-based NEs and IP [OSPF/RIP] for TCP/IP-based NEs. Or else, the operator may choose to work at physical layer which makes the implementation transparent from higher layers. The router for DCN networking in a city may use Ethernet over SDH transport to connect to IP/MPLS network. However, other possibilities are not ruled out. It is suggested to use 48V (-40V-60V) DC operated low range routers as per TEC GR No.: GR/TCP-01/ equipped with at least 2 Ethernet interfaces, one serial interface as LAN interfaces and 2 WAN Ports (which can be Nx64 Kbps or Ethernet). If the LAN ports are felt short of requirement, a LAN switch may be used, as above, to aggregate the transmission centers management traffic on fewer Ethernet ports. The exact network design and architecture for a DCN is out of scope for this document.

____________

- 90 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 91 -

APPENDIX II VLAN implementation in M-ADM/ADM equipment

- 91 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 92 -

VLAN implementation in the M-ADM/ADM equipment

Introduction Customers cannot be restricted for use of VLANs in their networks. Hence either translation of customer VLAN in to a S-VLAN unique in the aggregation network or issuance of VLAN to customers unique within service providers network are the possible solutions. Another compulsion is to maintain transparency to customer services. Hence VLAN stacking is inevitable. There needs be a separate VLAN for services and for service providers. This VLAN is relevant to the WANside. No visibility of customer changes (new entries or churns) shall be there if LAN is decoupled from MAN. Customer MAC to/from VLAN mapping is decoupled from LAN to WAN. There can be any MAC address behind an M-ADM/ADM. It shall give networking flexibility. Service segregation in aggregation transport network Two types of customer segregation are possible1. Customer based 2. Network based. Service identification may be based on source/destination MAC or IP addresses of the IP service-edges. Single VLAN carriage of customer traffic, in such case, is possible only with network-based service segregation. This simplifies customers access network but suffers from QoS issues. In customer-based segregation, VLANs are separate for various services. VLANs can be used for QoS differentiation or service segregation. A standard Ethernet network deploys Ethernet (VLAN) bridging. A VLAN bridge makes use of multiple separate virtual bridge instances. An incoming Ethernet frame is assigned to a particular virtual bridge based on its VLAN-ID. The VLAN-ID is a 12-bit field of the IEEE 802.1Q tag. For untagged frames (i.e., frames that are not 802.1Q tagged), the virtual bridge can be chosen based on either the port on which the Ethernet frame arrived or the Ethertype of the Ethernet frame. Each virtual bridge then performs an independent Ethernet forwarding process, deciding on which bridge (ports) to forward Ethernet frames to, based on the frames MAC destination address and its own MAC address forwarding table. Traffic cannot be exchanged between two virtual bridges. To obtain more flexible and more scalable use of VLAN-IDs, the IEEE 802.1ad stacked VLANs shall be used. This allows the tagging of Ethernet frames with two VLAN tags: the original VLAN tag, now called customer VLAN (C-VLAN) tag and a completely new service VLAN (S-VLAN) tag. For upstream traffic, the Transport node shall assign the user Ethernet frame to a VLAN based on 1. The port/VLAN, or 2. The VLAN tag (if the frame is already tagged), or 3. The protocol carried inside the Ethernet frame. Next, the virtual bridge corresponding to this VLAN forwards the Ethernet frame to one or more of the Ethernet ports, based on the frames MAC destination address. The outgoing frame carries a VLAN tag. In the intelligent bridging model, traffic from multiple subscribers gets VLAN tagged with the same VLAN-ID. Typically, the VLAN-ID will be unique per Transport node (not per subscriber). The VLAN tag that is applied is either a customer VLAN tag (C-TAG), or a service VLAN tag (S-TAG). Both tags have an identical structure, but are identified by a different Ethertype. C-VLANs will be used in combination with legacy VLAN-aware Ethernet switches in the aggregation network, while S-VLANs will be deployed in provider-bridged networks. It is also possible to apply a so-called VLAN stack i.e., a combination of a C-VLAN and an S-VLAN. This last solution makes it possible, for example, to use the CVLAN tag for service differentiation on the last mile. Figure 2 shows an example of the intelligent bridging model. The right side shows that Ethernet traffic from the black and the red virtual access-

- 92 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 93 -

port gets tagged with a blue VLAN (VLAN 1), while traffic from the blue virtual access-port gets tagged with an orange VLAN (VLAN 2). Note The structure of C-VLAN and S-VLAN shall be same as IEE 802.1p/q. Only the roles are different.

802.1q or 802.1ad

802.3 RFC 2516 ATM

802.3

DSL

ETHERNET

Access Link

Transport Uplink

Virtual port 1 line 1 Virtual port 2 line 1 Virtual port 1 line 2

VLAN1 VLAN2 VLAN1

Figure 1 - Cross-connect model Mapping of Figure 1 shall be primarily EPL/EVPL/EVPLAN/EPLAN/VPLS/IP-VPNs etc. implemented for SME/SOHO connectivity services-

802.1q or 802.1ad

802.3 RFC 2516 ATM

802.3

DSL

ETHERNET

Access Link Transport uplink

Virtual port 1 line 1 Virtual port 2 line 1 Virtual port 1 line 2

VLAN1 VLAN2 VLAN1

Figure 2 - Intelligent bridging model Mapping of Figure 2 shall be implemented for residential-service aggregation mainly. Any other use, however, not ruled out. Scalability statement of the network A C-VLAN unique to M -ADM/ADM shall be appended to customers Ethernet frame to identify the customer in aggregation network. 4094 customers per M-ADM/ADM ring shall thus be possible. In order to scale beyond this limit, VLAN stacking shall be used appending a service provider VLAN i.e., S-VLAN (unique to M-ADM/ADM) which shall be flexible used to identify M-ADM/ADM, a particular service or a particular service provider. There shall be 4094 customers possible per S-VLAN distinguished by unique (per M-ADM/ADM) C-VLAN. Theoretically, the number of S-VLANs per M-ADM/ADM shall be = 4094/(No. of M-ADM/ADM on the ring).

- 93 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 94 -

Total C-VLANs (unique supported in ring

to

packet

ring)

= = =

4094 4094 x 4094 4094 x 4094

Per ring VLAN support (with VLAN stacking) Theoretical no. of customers possible on a packet ring

The purchaser shall communicate VLAN scalability requirements depending upon deployed network size.

____________

- 94 -

GR No.: GR/SDH-07/01.MAR.2005 for Synchronous Multiplexer at STM-64 bit rates for metro applications

- 95 -

GLOSSARY
AIS BIP BITE CRT DCC ECC EMC EMS GDMO HOP HP-UNEQ LOF LOP LOP LOS LP-UNEQ MDU MIB MTU MDU MS-AIS MSOH MS-RDI MTBF MTTR NE NMS OSI PCM PICS POH QA REI SDH SNC-N STM-1e STM-1o TMN TSA TSI TUs VC Alarm Indicating Signal Bit Interleaved Parity Built-In Test Equipment Cathode Ray Tube Data Communication Channel Embedded Control Channel Electro-Magnetic Compatibility Element Management System General Definition of Managed Objects Higher Order Path Higher Path Unequipped Loss of Frame Loss of Pointer Lower Order Path Loss of Signal Lower Path Unequipped Multi-Dwelling Unit Management Information Base Multi-Tenant Unit Multi-Dwelling Unit Multiplex Section Alarm Indicating Signal Multiplex Section Over Head Multiplex Section Remote Defect Indication Mean Time Between Failure Mean Time To Restore Network Element Network Management System Open System Interconnection Pulse Code Modulation Protocol Information Compliance Statement Path Over Head Quality Assurance Remote Error Indication Synchronous Digital Hierarchy Sub-Network Connection Non-intrusive STM 1 Electrical STM 1 Optical Telecommunication Management Network Time Slot Assignment Time Slot Interchange Tributary Units Virtual Container

-------END OF DOCUMENT------