Sunteți pe pagina 1din 12

ACTUATOR FOR DAMPERS

Fire & Smoke Protection


Actuator with spring return 5 Nm 20 Nm

For the application with Fire dampers Smoke dampers

Page:
2 3 4 12 7 8 - 11

Content:
General overview fire & smoke protection Summary: Actuators for fire & smoke protection Technical characteristics, Type 229, 5 Nm Technical characteristics, Type 239, 20 Nm Your way to Gruner

GR

UNER he frie t

alte dly n

rnative

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

GENERAL OVERVIEW: FIRE & SMOKE PROTECTION

Fire Protection
= Standard = Optional

Type
Spring Return Torque (Actuator) Torque (Spring) Angle of Rotation

229
5 Nm (ca. 1 m )
2

239
20 Nm (ca. 4 m2) 15 Nm 100

4 Nm 100

Control
On/Off

Power Supply
24 VAC/DC 230 VAC

Options
Auxiliary switch(es) Thermal Tripping Device (72C) Thermal Tripping Device for Duct Mounting (72C)

Applications
Motorised control of fire and smoke dampers in HVAC systems. All actuators correspond to the DIN-VDE standards and CE guidelines.

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

20/06 FSOE Copyright by Gruner AG Technical changes are reserved

SUMMARY: ACTUATORS FOR FIRE & SMOKE PROTECTION 3

= Standard = Optional

Type
Torque (Actuator) Torque (Spring) On/Off Control Angle of Rotation

5 Nm 4 Nm 100

Power Supply
24 VAC/DC 230 VAC

Options
Thernal Tripping Device (72C) Thernal Tripping Device for Duct Mounting (72C) Auxiliary switch(es) Page 4 4 6 6 8 8 8 10 10 10

Actuators typ 239 dispose of the manual override option by crank. Actuators according to US standard available upon demand.

Important Note
The modification and mounting of the actuator to the fire damper is made by the manufacturer of the damper. For this reason the spring-return actuator is only supplied directly to manufacturers of fire dampers. The manufacturer then bears overall responsibility for proper functioning of the damper.

GRUNER AG PF 1149, D-78560 Wehingen

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

22 902 405 22 -S 9T 2 A02 422 05 9-S 23 2 005 22 -S 9T 2 A23 005 -S 2 23 902 420 23 -S 9T 2 -0 24 -2 23 09T S2 A02 423 20 9-S 23 2 020 23 -S 9T 2 -2 30 -2 23 09T S2 A23 020 -S 2
5 Nm 4 Nm 100 5 Nm 4 Nm 100 5 Nm 4 Nm 100 20 Nm 20 Nm 20 Nm 20 Nm 20 Nm 20 Nm 15 Nm 15 Nm 15 Nm 15 Nm 15 Nm 15 Nm 100 100 100 100 100 100

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

229-024-05-S2, 229TA-024-05-S2
Applications
To regulate fire and smoke dampers in HVAC systems: Form-locking steel drive Torque 5 Nm / 4 Nm Angle of rotation 100 Hold safe position in case of high temperature no manual operation and position fixing reliable safe postion Electromagnetic compatibility controlled

Technical Characteristics
Control Connecting voltage Power consumption Transformer sizing Angle of rotation Direction of rotation Running time (90) Torque Auxiliary switches Switching power Auxiliary switches Connection Safety class Protection Dimensions Ambient temperature Maintenance CE Weight On/Off 24 VAC (50/60 Hz) / DC 20% Motion: 5.0 W / Power safe mode: 3.0 W 6.5 VA 100 (-5...+95) can be selected by mounting back to front Actuator: < 40...75 s / Spring: < 20 s Actuator: 5 Nm / Spring: 4 Nm 2, position fixed to 5 and 80 250 VAC / 5.0 (2.5) A, change-over switch Cable 900 mm / 0.75 mm2 III IP54 (Cable downwards) 158 x 66 x 61 mm -30C...+50C maintenance-free 73/23/EWG, 89/336/EWG 1,100 g

229-024-05-S2
Connection scheme S1 S2
1 2 3 4 5 6

229TA-024-05-S2
Connection scheme S1 S2 1 2 3 4 5 6 TA
TF1 TF2

BU BN

BU BN

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

229-024-05-S2, 229TA-024-05-S2
1 Fixing of the shaft
Concentric form locking shaft: 8...12 mm

Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of the damper can be read on the scale on front of the actuator.

Thermal tripping devices (Fig. 1 + 2)


Version TA Self test Duct temperature Ambient temperature Yes Yes Yes

If 72C are reached the actuator turns the damper back to its safe position.

2
2.00

Thermal tripping device TA

50.00 20.00 20.00

2.8...3 9.5...10

27.60

107.002.00

50.00 40.00

2.8...3

66.001.00

9.00

Technical drawing
229-024-05-S2

R2

157.001.00

.0

93.000.50 82.50 48.50

2.00

12.00

0 ,2

13.00

1,2,3,4,5,6 11.00

GRUNER AG PF 1149, D-78560 Wehingen

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

N ,B BU

66.001.00

,4

12.20

52.00
TA

61.001.00

,6 ,8

6.00

12.20

13.00

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

1
R65 .00

R1 1

.00
66.00

2.00

http://www.gruner.de E-Mail: info@gruner.de

229-230-05-S2, 229TA-230-05-S2
Applications
To regulate fire and smoke dampers in HVAC systems: Form-locking steel drive Torque 5 Nm / 4 Nm Angle of rotation 100 Hold safe position in case of high temperature no manual operation and position fixing reliable safe postion Electromagnetic compatibility controlled

Technical Characteristics
Control Connecting voltage Power consumption Transformer sizing Angle of rotation Direction of rotation Running time (90) Torque Auxiliary switches Switching power Auxiliary switches Connection Safety class Protection Dimensions Ambient temperature Maintenance CE Weight On/Off 230 VAC (50/60 Hz) 15% Motion: 5.0 W / Power safe mode: 2.5 W 5.5 VA 100 (-5...+95) can be selected by mounting back to front Actuator: < 40...75 s / Spring: < 20 s Actuator: 5 Nm / Spring: 4 Nm 2, position fixed to 5 and 80 250 VAC / 5.0 (2.5) A, change-over switch Cable 900 mm / 0.75 mm2 II IP54 (Cable downwards) 158 x 66 x 61 mm -30C...+50C maintenance-free 73/23/EWG, 89/336/EWG 1,100 g

229-230-05-S2
Connection scheme S1 S2 1 2 3 4 5 6

229TA-230-05-S2
Connection scheme S1 S2 1 2 3 4 5 6 TA
TF1 TF2

BU BN

BU BN

N L

N L

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

229-230-05-S2, 229TA-230-05-S2
1 Fixing of the shaft
Concentric form locking shaft: 8...12 mm

Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of the damper can be read on the scale on front of the actuator.

Thermal tripping devices (Fig. 1 + 2)


Version TA Self test Duct temperature Ambient temperature Yes Yes Yes

If 72C are reached the actuator turns the damper back to its safe position.

2
2.00

Thermal tripping device TA

50.00 20.00 20.00

2.8...3 9.5...10

27.60

107.002.00

50.00 40.00

2.8...3

66.001.00

9.00

Technical drawing
229-230-05-S2

R2

157.001.00

.0

93.000.50 82.50 48.50

2.00

12.00

0 ,2

13.00

1,2,3,4,5,6 11.00

GRUNER AG PF 1149, D-78560 Wehingen

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

N ,B BU

66.001.00

,4

12.20

52.00
TA

61.001.00

,6 ,8

6.00

12.20

13.00

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

1
R65 .00

R1 1

.00
66.00

2.00

http://www.gruner.de E-Mail: info@gruner.de

239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2


Applications
To regulate fire and smoke dampers in HVAC systems: Form-locking steel drive Torque 20 Nm / 15 Nm Angle of rotation 100 Hold safe position in case of high temperature manual operation and position fixing reliable safe postion Electromagnetic compatibility controlled

Technical Characteristics
Control Connecting voltage Power consumption Transformer sizing Angle of rotation Direction of rotation Running time (90) Torque Auxiliary switches Switching power Auxiliary switches Connection Safety class Protection Dimensions Ambient temperature Maintenance CE Weight On/Off 24 VAC (50/60 Hz) / DC 20% Motion: 6.5 W / Power safe mode: 4,0 W 10 VA 100 (-5...+95) can be selected by mounting back to front Actuator: 150 s / Spring: < 20 s Actuator: 20 Nm / Spring: 15 Nm 2, position fixed to 5 and 80 250 VAC / 5.0 (2.5) A, change-over switch Cable 900 mm / 0.75 mm2 III IP54 (Cable downwards) 250 x 98 x 58 mm -30C...+50C maintenance-free 73/23/EWG, 89/336/EWG 2,500 g

239-024-20-S2
Connection scheme S1 S2
1 2 3 4 5 6

239T-024-20-S2
Connection scheme S1 S2 1 2 3 4 5 6 T
TF1

239TA-024-20-S2
Connection scheme S1 S2 1 2 3 4 5 6 TA
TF1 TF2

BU BN

BU BN

BU BN

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2


1 Fixing of the shaft
Concentric form locking shaft: 8...12 mm

Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of the damper can be read on the scale on front of the actuator.

Thermal tripping devices (Fig. 1 + 2)


Version T Self test Duct temperature Ambient temperature No No Yes Version TA Yes Yes Yes

If 72C are reached the actuator turns the damper back to its safe position.

2
2.00

Thermal tripping device TA

50.00 20.00 20.00

2.8...3 9.5...10

27.60

107.002.00

50.00 40.00

2.8...3

66.001.00

9.00

Technical drawing
6(6x) 10

239-024-20-S2
R1

Motor bl, br

S1, S2 80 1, 2, 3, 4, 5, 6

80

36

98

58 2

24

43

27 149 250 67

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

15

10

239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2


Applications
To regulate fire and smoke dampers in HVAC systems: Form-locking steel drive Torque 20 Nm / 15 Nm Angle of rotation 100 Hold safe position in case of high temperature manual operation and position fixing reliable safe postion Electromagnetic compatibility controlled

Technical Characteristics
Control Connecting voltage Power consumption Transformer sizing Angle of rotation Direction of rotation Running time (90) Torque Auxiliary switches Switching power Auxiliary switches Connection Safety class Protection Dimensions Ambient temperature Maintenance CE Weight On/Off 230 VAC (50/60 Hz) 15% Motion: 9.0 W / Power safe mode: 7,0 W 10.0 VA 100 (-5...+95) can be selected by mounting back to front Actuator: 150 s / Spring: < 20 s Actuator: 20 Nm / Spring: 15 Nm 2, position fixed to 5 and 80 250 VAC / 5.0 (2.5) A, change-over switch Cable 900 mm / 0.75 mm2 II IP54 (Cable downwards) 250 x 98 x 58 mm -30C...+50C maintenance-free 73/23/EWG, 89/336/EWG 2,500 g

239-230-20-S2
Connection scheme S1 S2 1 2 3 4 5 6

239T-230-20-S2
Connection scheme S1 S2
1 2 3 4 5 6 T
TF1

239TA-230-20-S2
Connection scheme S1 S2 1 2 3 4 5 6 TA
TF1 TF2

BU BN

BU BN

BU BN

N L

N L

N L

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2


1 Fixing of the shaft
Concentric form locking shaft: 8...12 mm

11

Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of the damper can be read on the scale on front of the actuator.

Thermal tripping devices (Fig. 1 + 2)


Version T Self test Duct temperature Ambient temperature No No Yes Version TA Yes Yes Yes

If 72C are reached the actuator turns the damper back to its safe position.

2
2.00

Thermal tripping device TA

50.00 20.00 20.00

2.8...3 9.5...10

27.60

107.002.00

50.00 40.00

2.8...3

66.001.00

9.00

Technical drawing
6(6x) 10

239-230-20-S2
R1

Motor bl, br

S1, S2 80 1, 2, 3, 4, 5, 6

80

36

98

58 2

24

43

27 149 250 67

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

15

YOUR WAY TO GRUNER

Stuttgart

A8

Mnchen

Balingen Karlsruhe
Schmberg

Freudenstadt

A81

Wehingen
B27
Gosheim Frittlingen Denkingen

Tuttlingen

Strasbourg

Rottweil B14
Schramberg Aldingen

Spaichingen

Offenburg A5 B33 Freiburg B31

34
B27

Donaueschingen

Singen Zrich

Basel N1 N3

GRUNER AG PF 1149, D-78560 Wehingen

Tel. (++49) 74 26 / 948 - 0 Fax (++49) 74 26 / 948 - 200

http://www.gruner.de E-Mail: info@gruner.de

16/07 FSOE Copyright by Gruner AG Technical changes are reserved

S-ar putea să vă placă și