Documente Academic
Documente Profesional
Documente Cultură
Selection table
N-9
N-18
N-23
N-28
N-32
N-32
N-37 N-37
N-13
N-3
N-42 N-48
N-53 N-53
1) Safety
N-0
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
Safety relays
A B C D E
aaaaaaaaaaaaaaaaaaaaaaaaaa
Technical specifications
Type of unit
F G H I J K L M N O P Q R
Emergency stop
Automatic reset
Expansion unit
Safety switch
Main unit
Muting
Product UE10-3OS UE23-2MF UE42-2HD UE43-2MF UE43-3MF UE43-6MF UE44-3SL UE45-3S1 UE48-2OS UE48-3OS UE49 LE20 LE20 Muting UE10-4XT UE11-4DX
Page N-3 N-9 N-13 N-18 N-23 N-28 N-37 N-32 N-42 N-48 N-53 N-57 N-64 N-71 N-74
0.5 0.22 3
1)
1 or 2 1 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 1 or 2 6 2 2
22.5 22.5 22.5 22.5 45.0 90.0 22.5 22.5 22.5 22.5 45.0 100.2 100.2 22.5 22.5
4 2) 4 4 4 4 4 4 4 4 4 2 2 6) 6)
1) 2)
/0
5) 5)
oder
Same as protective device The wires for the input and output signals shall be routed outside the control cabinet according to the category to be used 3) One normally open contact on-delayed 4) One normally open contact off-delayed
Testable Same as main unit 7) 4 normally open contacts / 2 normally closed contacts with off-delay function
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N-1
Safety relays
Symbols
Off-delay On-delay Function
EDM
Expansion unit
Safety switch
Emergency stop
Applications
Two-hand controls
N-2
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE10-3OS
UE10-3OS
A B C D E F G
For For
Product description
N/C
contact for external device monitoring (EDM) 2 LEDs for: Relay K1 Relay K2
of the expansion units UE10-4XT UE11-4DX Available with plug-in terminals (key coded)
Applications
D1 OSS D2 OSS
S3000
or
3 1
H I J K L
OSS
OS SD
D1
2
C4000
systems with monitored semiconductor outputs, integral external device monitoring and restart interlock, such as LSI LE20
M
Further information Page N-2
Symbols
N O P Q R
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE10-3OS2D0 UE10-3OS3D0 Part number 6024917 6024918
Internal circuitry
N-5
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N-3
UE10-3OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Inputs B1 ... B4
Activation time Switch-on voltage Switch-on current 40 ms 24 V (15 V ... 30 V) 500 mA
Contact type Contact material Load capacity of contacts Switching voltage enable current paths/signalling current paths Switching voltage contactor monitoring Switching current enable current paths Switching current signalling current paths Switching current contactor monitoring Total current across all contacts Application category according to EN 60947-5-1
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) Weight IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 0.2 kg 3 2 300 V AC 2.0 kV 4 kV III
N-4
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE10-3OS
Internal circuitry
13 23 33 B1 Y1 Y2 B3
A B
33 41 13 23
B1
B2
Y1
C D E F
External device monitoring (EDM) Category 3 or 4 according to EN 954-1 requires monitoring of contactors. This is provided in the connected protective device, for example in the C4000 or S3000. The normally closed contact (Y1 -Y2) in the UE10-3OS unit is, however, a part of this contactor monitoring system.
CH 1
K1
CH 2
K2
B3
B4
Y2
42 B2 41
14 42
24 B4
34
14
24
34
Function If the semiconductor outputs of the installed safety device (e.g. C4000, S3000) are energised, then the safety output contacts will close. When at least one of the semiconductor outputs of the safety device becomes de-energised, then the output contacts revert back to open circuit status. If restart interlock is needed, then this is achieved in the safety device, for example C4000 or S3000.
G H I J K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N-5
UE10-3OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Dimensional drawings
82.5 63 78 58
107.6
114
107.6
93.6
93.3 96.5
75.3
93.3 96.5
22.5
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
N-6
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
22.5
7024240
93.7
114
Safety relays
UE10-3OS
Connection diagrams
Safety light curtain C4000 Standard/Advanced connected to UE10-3OS safety relay
+ 24 V
A B C D E
B1 B3 UE10-3OS Y 1 13 23 33 41 S1
1 3 4 5 6 2 FE
+ 24 V Test n. c. n. c. n. c. 0V FE
1 5 6 3 4 2 FE
C4000S
C4000R
F
Y 2 14 24 34 42
B2 B4
G H I J K
0V
Operating mode: with manual reset and external device monitoring (active)
S1
6 2 WH BN GN
1 2 3 4
1 2 3 4 5 6 7 8
WH BN GN YE GY PK BU
L M
B1 B3 Y 1 13 23 33 41 UE10-3OS B2 B4 Y 2 14 24 34 42
GY
5 6
BU
7 8
C2000S
C2000R
N O P
Continued on next page
0V
Q
N-7
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
UE10-3OS
Safety relays
A B C D E F G H I J K L M N
S1
S3000
1 5 6 7 8 9 4 3 2
B1 B3 UE10-3OS B2 B4
Y 1 13
23
33
41
Y 2 14
24
34
42
0V
S1
2 5 1 3 4 7 FE
+ 24 V Test n. c. n. c. n. c. 0V FE
2 1 4 5 6 7 FE B1 B3 Y 1 13 23 33 41
C4000S
C4000R
UE10-3OS
B2 B4
Y 2 14
24
34
42
0V
O P Q R
N-8
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE23-2MF
UE23-2MF
A B C D E F G
For For
wires for the input and output signals shall be routed outside the control cabinet according to the category to be used.
Product description
2
of the expansion units UE10-4XT UE11-4DX External device monitoring (EDM) Screw-type terminals
Applications
emergency stops safety switches
H I J K
2 1
or
EDM
L M
Part number 6026146 6026147 6026148 Further information Page N-2 Type UE23-2MF2D3 UE23-2MF2A4 UE23-2MF2A3
Ordering information
Supply voltage 24 V DC 115 ... 120 V AC 230 V AC
N O P Q R
Symbols
7024240
N-9
UE23-2MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Power consumption
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1
1)
The wires for the input and output signals shall be routed outside the control cabinet according to the category to be used
N - 10
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE23-2MF
Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2
A B C D E F G
Weight
0.27 kg
Internal circuitry
A1 A2 Y1 Y2 Y3 13 23 31
K1 K2
H I
14 24 32
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain in the open state. If the connected sensor is not activated (i.e. the input circuits are closed), then the normally open contacts close immediately in automatic Reset (LED K1, K2 illuminates). In the case of manual reset, this only occurs after pressing the reset button.
External device monitoring (EDM) The unit can take over the function of external device monitoring. The contactor monitoring system monitors the external relays through their normally closed contacts. Manual reset For manual resetting a pushbutton must be connected to terminals Y1 and Y3. This reset is monitored. Automatic reset For automatic resetting, Y1 - Y2 must be linked.
J K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 11
UE23-2MF
Safety relays
A B C E F G H I J K L M N O P Q R D
Dimensional drawings
93.5 71.5 22.5
123 96 61.2
75.5
55.5 76.5
Housing with screw-type terminals
Dimensions in mm
N - 12
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE42-2HD
UE42-2HD
A B C D E F G
For
Dual-channel 22.5 mm
Product description
3
of the expansion unit UE10-4XT device monitoring (EDM) Available with plug-in terminals (key coded)
External
Applications
two-hand controls Typ III C in accordance with EN 574 For safety switches 2 1
H I J K L M
EDM
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE42-2HD2D2 UE42-2HD3D2 Part number 6024878 6024881
Further information
Page N-2
Symbols
N O P Q R
7024240
N - 13
UE42-2HD
Safety relays
A B C D E F G H I J K L M N O P Q R
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
N - 14
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE42-2HD
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 EN 60947-1 02/99 EN 60947-1 02/99 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
A B C D E F G H I J K
Weight
0.2 kg
Internal circuitry
A1 A2 Y1 Y2 Y11 Y12 Y14 13 23 31
Feedback
Channel 1 K1
Control-Logic Channel 2 K2
14
24
32
L
External device monitoring (EDM) The UE42-2HD can take over the function of external device monitoring. The normally closed contacts of the external relays are switched in series, connected to the terminals Y1 - Y2. Automatic start The UE42-2HD has an automatic start facility. Monitoring of simultaneous activation The pressing of the start buttons at the same time is monitored. Only when both start buttons are activated within 0.5 sec do normally open contacts close and the normally closed contact opens.
Function The UE42-2HD unit corresponds to EN 574 Type III C. A prerequisite for the release of the outputs is that the two inputs (e.g. two-hand pushbuttons) are actuated within 0.5 sec. After applying the supply voltage to the terminals A1 - A2 the LED SUPPLY illuminates to indicate that electrical power is present. Pressing the two-hand pushbuttons S1 and S2 at the same time (see page N-17 connection diagrams) closes the two normally open contacts. Releasing even one of the buttons will cause the circuits to adopt the open circuit status. A renewed attempt to initiate starting is only possible if both start buttons are set to their nominal start position (for twohand pushbuttons units: if both have been released) and the normally closed contact is closed.
M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 15
UE42-2HD
Safety relays
A B C D E F G H I J K L M N O P Q R
Dimensional drawings
82.5 63 78 58
107.6
107.6
93.6
114
75.3
93.3 96.5
93.3 96.5
22.5
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
N - 16
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
22.5
7024240
93.7
114
Safety relays
UE42-2HD
Connection diagrams
Two-hand control with UE42-2HD safety relay, dual-channel system
+ 24 V
A B C D
S2
S1
Y12 S14
Y22
Y24 A1
13
23
31
E F G
K2
UE42-2HD
Y11 Y21 Y1 Y2 A2 14 24 32
k1
k2 K1
0V
H I J K L
Operating mode: with automatic start and external device monitoring (EDM)
Y12 S14
Y22
Y24 A1
13
23
31
UE42-2HD
Y11 Y21 Y1 Y2 A2 14 24 32
M N O
K2
k1
k2 K1
0V
Operating mode: with automatic reset and external device monitoring (EDM)
P Q
N - 17
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
UE43-2MF
UE43-2MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2 N-20
For For
Product description
Cross
circuit detection on dual-channel wired systems 3 LEDs: Supply voltage Relay K1 Relay K2
Manual
reset reset Increase in the number of outputs by way of the expansion units UE10-4XT UE11-4DX External device monitoring (EDM) Available with plug-in terminals (key coded)
Automatic
Applications
emergency stops safety switches 2 1
or
EDM
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE43-2MF2D2 UE43-2MF3D2 Part number 6024893 6024894
N - 18
7024240
Safety relays
UE43-2MF
A B C D E F G H I J K L M N O P
Continued on next page
Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Q R
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 19
UE43-2MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
Internal circuitry
A1 A2 S34 S35 S12 S31 13 23 31
+
K1
--
ControlLogic
K2
--
K2 24 32
S22 14
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain in the opened state. If the connected sensor is not activated (i.e. the input circuits are closed), then the normally open contacts close immediately in automatic reset (LED K1 and K2 illuminate). In the case of manual reset, this only occurs after pressing and releasing the reset button. Activation of the sensor (opening of one or both input circuits) effects the opening of the normally open outputs. External device monitoring (EDM) The UE43-2MF unit can take over the function of external device monitoring. The contactor monitoring system monitors the external relays by means of their normally closed contacts.
Manual reset For manual resetting a pushbutton must be connected to terminals S33 - S34. Reset is monitored. Automatic reset For automatic resetting, S12 - S35 must be linked. Cross circuit detection Cross circuit is detected on dual-channel wired systems if these are wired with opposing polarity. Monitoring of synchronisation Only if input 2 closes by no later than 0.5 sec after input 1 do the output circuits close. If input 2 closes before input 1, the monitoring of synchronisation will not be effected, and the output circuits will close. This monitoring only takes place in automatic reset.
N - 20
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE43-2MF
Dimensional drawings
82.5 63 78 58
A B C D
93.7 114
107.6
93.6
114
107.6
E F G
75.3
93.3 96.5
93.3 96.5
22.5
22.5
H I J K L M N O P Q
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 21
UE43-2MF
Safety relays
A B C D
Connection diagram
Two safety switches i10 to UE43-2MF safety relay, dual-channel system
+24 V
21
13 i10
S1
S33 S11 S31 S21 A1 13 23 31
E F G H I J K L M N O P Q R
N - 22
21 22
22
14 B2 13 i10 14 B1
k1 k2
UE43-2MF
S34 S35 S12 S22 A2 14 24 32
H4 (rd) 0V
K1
K2
Operating mode: with manual reset and external device monitoring (EDM)
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE43-3MF
UE43-3MF
A B C D E F G
For For
Single- or dual-channel 45 mm
Product description
Cross
circuit detection on dual-channel wired systems 3 LEDs: Supply voltage Relay K2 Relay K3
Manual
reset Automatic reset Increase in the number of outputs by way of the expansion units UE10-4XT UE11-4DX External device monitoring (EDM)
Applications
emergency stops safety switches
H I J K L M
or
EDM
Ordering information
Supply voltage 24 V DC 24 V AC 115 V AC 120 V AC 230 V AC Type UE43-3MF2D3 UE43-3MF2A0 UE43-3MF2A1 UE43-3MF2A2 UE43-3MF2A3 Part number 6024897 6024898 6024899 6024900 6024901 Further information Page N-2
Symbols
N O P Q R
7024240
N - 23
UE43-3MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Power consumption
N - 24
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE43-3MF
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
A B C D E F G H I J K L M N O P Q
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.75 mm2 ... 2.5 mm2 0.75 mm2 ... 2.5 mm2 0.5 mm2 ... 1.5 mm2 0.5 mm2 ... 1.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 25
UE43-3MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Internal circuitry
A1 A2 Y13 Y14 Y12 Y12 Y31
13 23 33
41
K2 K3
+ --
K1 Y11 Y21
K2 Y22
K3
-14 24 34 42 42
Function After applying the supply voltage (LED SUPPLY illuminates) the normally open contacts remain open. If the connected sensor is not activated (i.e. the input circuits are closed), the normally open contacts close immediately in automatic reset (LED K2 and K3 illuminate). In the case of manual resetting, this is only effected upon pressing and releasing the reset button. Activation of the sensor (opening of one or both input circuits) effects the opening of the normally open contacts (LED K2 and K3 off). External device monitoring (EDM) The UE43-3MF unit can take over the external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts.
Manual reset For manual resetting a pushbutton must be connected to terminals Y12 and Y13. Reset is monitored. Automatic reset For automatic resetting Y12 - Y14 must be linked. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity. Monitoring of synchronisation Only if input 2 closes by no later than 0.5 sec after input 1 do the output circuits close. If input 2 closes before input 1, the monitoring of synchronisation will not be effected, and the output circuits will close. This monitoring only takes place in automatic reset.
N - 26
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE43-3MF
Dimensional drawings
for mounting rail EN 50 022
A B C
107 120.5
Dimensions in mm
52.5
75 3.8
45
D E F
+ 24 V
Connection diagram
Emergency stop switch connected to UE43-3MF2D3 safety relay
+ 24 V
G
S1
A)
S1
B)
H I J
Y13 Y11 Y14 A1 13 23 33 41
k1 k2
k1 k2
S0
Y13 Y11 Y14 A1 13 23 33 41
S0
UE43-3MF2D3
Y31 Y12 Y21 Y22 A2 14 24 34 42
UE43-3MF2D3
Y31 Y12 Y21 Y22 A2 14 24 34 42
K L M N O P Q
K1 0V
K2 0V
K1
K2
Operating mode: with manual reset and external device monitoring A) single-channel system B) dual-channel system
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 27
UE43-6MF
UE43-6MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2 N-31
For For
Product description
Cross
circuit detection on dual-channel wired systems 6 LEDs: Supply voltage Input circuit CH1 Input circuit CH2 Relay K1 Relay K2 Relay K3 RESET
Manual
reset reset Increase in the number of outputs by way of the expansion modules UE10-4XT UE11-4DX External device monitoring (EDM)
Automatic
6 4
Applications
or
EDM
Ordering information
Supply voltage 24 V DC 120 V AC 230 V AC Type UE43-6MF2D3 UE43-6MF2A2 UE43-6MF2A3 Part number 6024902 6024905 6024906
N - 28
7024240
Safety relays
UE43-6MF
A B C D E F G H I J K L M N O P
Continued on next page
Power consumption
Output circuits (13 - 14, 23 - 24, 33 - 34, 43 - 44, 53 - 54, 63 - 64, 71 - 72, 81 - 82, 91 - 92, 01 - 02)
Response time (K1 / K2) Relay contacts Contact type Contact material Load capacity of contacts Switching voltage Switching current Total current across all contacts Application category according to EN 60947-5-1 10 V AC ... 230 V AC / 10 V DC ... 30 V DC 10 mA ... 6 A 24 A AC-15 Ue 230 V AC, Ie 3 A (3600 c/h) DC-13 Ue 24 V DC, Ie 6 A (360 c/h) DC-13 Ue 24 V DC, Ie 2 A (3600 c/h) 3600 c/h 1 x 107 switching cycles 2 x 106 switching cycles 60 ms 6 N/O, enable current paths, safety relevant 4 N/C, signalling current paths, not safety relevant Positively guided Silver alloy; gold-plated
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Q R
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 29
UE43-6MF
Safety relays
A B C D E F G H I J K L M N O P Q R
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.75 mm2 ... 2.5 mm2 0.75 mm2 ... 2.5 mm2 0.5 mm2 ... 1.5 mm2 0.5 mm2 ... 1.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.8 kg
N - 30
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE43-6MF
Internal circuitry
A1 A2 S33 S34 Y1 S37 S11 S12 13 23 33 43 53 63 71 81 91 01 (+) K1 K3 CONTROL LOGIC
A B C
14 24 34 44 54 64 72 82 92 02
RESET
CH1
SUPPLY
Feedback CH2 ()
K2 (+)
Y1
Y2
S21 S22 Y3
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain open. If the connected sensor is not activated, the LEDs CH1 and CH2 illuminate. In the case of automatic resetting, the normally open contacts close immediately (LEDs K1 and K2 illuminate). With manual resetting the normally open contacts only close upon pressing and releasing the reset button. The activation of the sensor (opening of one or both input circuits) effects the opening of the normally open contacts (LEDs K1 and K2 off). External device monitoring (EDM) The UE43-6MF unit can take over the external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts.
Manual reset For manual reset a pushbutton is to be connected between contacts S12 and S34 and Y1 - S37 must be jumpered. This reset is monitored. Automatic reset S12 - S34 must be jumpered. Y1 - Y37 is not jumpered. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity. Monitoring of synchronisation Only if input 2 closes by no later than 0.5 sec after input 1 do the output circuits close. If input 2 closes before input 1, the monitoring of synchronisation will not be effected, and the output circuits will close. This monitoring only takes place in automatic reset.
D E F G H I J K L
Dimensional drawings
for mounting rail EN 50022
52.5 75
3.8
90
107 120.5
Dimensions in mm
M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 31
UE45-3S1
UE45-3S1
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2
For For
Product description
Cross
circuit detection on dual-channel wired systems Outputs: 2 normally open contacts 1 normally open contact with off-delay, adjustable from 0.15 ... 3 s or 1.5 ... 30 s 3 LEDs: Supply voltage Relay K1 / K2 (without delay) Relay K3 / K4 (delayed) emergency stops safety switches
Manual
reset reset Increase in the number of outputs by way of the expansion modules UE10-4XT UE11-4DX External device monitoring (EDM) Available with plug-in terminals (key coded)
Automatic
Applications
2 1
+
or
EDM
Ordering information
Off-delay time 0.15 s ... 3 s 1.5 s ... 30 s Connection type Screw-type terminals Plug-in terminals Screw-type terminals Plug-in terminals Type UE45-3S12D33 UE45-3S13D33 UE45-3S12D330 UE45-3S13D330 Part number 6024911 6024912 6024913 6024914
Symbols
N - 32
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE45-3S1
A B C D E F G H I J K L M N O P Q
N - 33
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
UE45-3S1
Safety relays
A B C D E F G H I J K L M N O P Q R
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 EN 60947-1 02/99 EN 60947-1 02/99 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
Internal circuitry
A1 A2 S33 S34 S35 13 23 37
+
RESET CONTROL- LOGIC Channel 1 Channel 2 (+ ) ( ) K1 K2 K3 K4
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain open. If the connected sensor is not activated (i.e. the input circuits are closed), the normally open contacts close immediately during automatic resetting, LED K1 / K2 and K3 / K4 illuminate. In the case of manual resetting, this only occurs after pressing and releasing the reset button. The activation of the sensor (opening of one or both input circuits) effects the opening of both normally open contacts (13 - 14 / 23 - 24) immediately, and a time delayed closing of the third circuit (37 - 38), with LED K1 / K2 immediately going off and K3 / K4 going off later. External device monitoring (EDM) The unit can take over external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts.
Manual reset For manual resetting, a pushbutton must be connected to terminals S33 - S34. This reset is monitored. Automatic reset For automatic resetting S33 - S35 must be linked. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity. Monitoring of synchronisation Only if input 2 closes by no later than 0.5 sec after input 1 do the output circuits close. If input 2 closes before input 1, the monitoring of synchronisation will not be effected, and the output circuits will close. This monitoring only takes place in automatic reset.
N - 34
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE45-3S1
Dimensional drawings
82.5 63 78 58
A B C D
93.7 114
107.6
93.6
114
107.6
E F G
75.3
93.3 96.5
93.3 96.5
22.5
22.5
H I J K L M N O P Q
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 35
UE45-3S1
Safety relays
A B C D E F G H I J K L M N O P Q R
Connection diagram
Two safety switches connected to UE45-3S1 safety relay
+ 24 V
S1
k1
k2
13
23
37
UE45-3S1
S11 S31 S12 S22 A2 14 24 38
K1
K2 0V
M 3
Operating mode: with manual reset and external device monitoring (EDM)
N - 36
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE44-3SL
UE44-3SL
A B C D E F G
For
Product description
Cross
circuit detection on dual-channel wired systems Outputs: 2 normally open contacts 1 on-delayed response time enable current path, adjustable from 0.15 ... 3 s or 1.5 ... 30 s 3 LEDs: Supply voltage Relay K1 / K2 (without delay) Relay K3 / K4 (delayed)
Manual
reset reset Increase in the number of outputs by way of the expansion modules UE10-4XT UE11-4DX External device monitoring (EDM) Available with plug-in terminals (key coded)
Automatic
Applications
emergency stops safety switches For safety switches with mechanical locking
For
H I J K L M
2 1
+
or
EDM
Ordering information
On-delay time 0.15 s ... 3 s 1.5 s ... 30 s Connection type Screw-type terminals Plug-in terminals Screw-type terminals Plug-in terminals Type UE44-3SL2D33 UE44-3SL3D33 UE44-3SL2D330 UE44-3SL3D330 Part number 6024907 6024908 6024909 6024910
Further information
N O P Q R
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 37
UE44-3SL
Safety relays
A B C D E F G H I J K L M N O P Q R
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category 4 kV III Continued on next page
N - 38
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE44-3SL
Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 EN 60947-1 02/99 EN 60947-1 02/99 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV
A B C D E F G H I J
Weight
0.2 kg
Internal circuitry
A1 A2 S33 S34 S35 13 23 37
+
RESET CONTROL-LOGIC Channel 1 Channel 2 (+) (-) K1 K2 K3 K4
K
Manual reset For manual resetting, a pushbutton is to be connected between 24 V DC supply and terminal S34. This reset is monitored. For applications with mechanical locking safety switches, only channel 2 must be closed during manual reset. Automatic reset For automatic resetting S 12 - S35 must be linked. For applications with mechanical locking safety switches, only channel 1 must be closed during automatic reset. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity. Monitoring of synchronisation Only if input 2 closes by no later than 0.5 sec after input 1 do the output circuits close. If input 2 closes before input 1, the monitoring of synchronisation will not be effected, and the output circuits will close. This monitoring only takes place in automatic reset.
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts (13 - 14 / 23 - 24) remain open. After completion of the on-delay set on the relay, the delay circuit (37 - 38) closes, and the LED K3 / K4 illuminates. If the connected sensor is not activated (i.e. the input circuits are closed), the normally open contacts (13 - 14 / 23 - 24) close immedi-ately during automatic reset, the LED K1 / K2 illuminates, and the delay circuit (37 - 38) opens (LED K3 / K4 off). In the case of manual reset, this only occurs after pressing and releasing the reset button. The activation of the sensor (opening of one or both input circuits) effects the opening of both normally open contacts (13 - 14 / 23 - 24), with LED K1 / K2 being off, and a time delayed closing of the third circuit (37 - 38), with LED K3 / K4 illuminating. External device monitoring (EDM) The unit can take over external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts.
L M N O P Q R
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 39
UE44-3SL
Safety relays
A B C D E F G H I J K L M N O P Q R
Dimensional drawings
82.5 63 78 58
107.6
107.6
93.6
114
75.3
93.3 96.5
93.3 96.5
22.5
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
N - 40
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
22.5
7024240
93.7
114
Safety relays
UE44-3SL
Connection diagram
i200 Lock safety switch (with mechanical locking) connected to UE44-3SL safety relay
+ 24 V
A B C
S1 S4
D E
13 23 37
k1 k2 11 21 33 41 53 E1
S11 S21 S35 S34 A1
F G H I
UE44-3SL
S33 S31 S12 S22 A2 14 24 38
i200 Lock
12 23 34
42
54
E2
K1 0V
K2
J K L M N O P Q
Operating mode: with manual reset and external device monitoring (EDM)
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 41
UE48-2OS
UE48-2OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2 N-44
For
Product description
Cross
circuit detection on dual-channel wired systems 3 LEDs: Supply voltage Relay K1 Relay K2 Manual reset
Automatic
reset
of the expansion modules UE10-4XT UE11-4DX External device monitoring (EDM) Available with plug-in terminals (key coded)
Applications
or or
or
OSSD 1
emergency stops safety switches For safety laser scanners For safety light curtains For non-contact safety switches For pressure sensitive mats in accordance with EN 1760 using 4-wire technology
For
OSSD 2
OS SD 1
OS SD
or
2 1
EDM
Compact
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE48-2OS2D2 UE48-2OS3D2 Part number 6024915 6024916
N - 42
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE48-2OS
A B C D E F G H I J K L M N O P Q R
N - 43
25 ms 70 ms ... 130 ms 2 N/O, enable current paths, safety relevant 1 N/C, signalling current path, not safety relevant Positively guided Silver alloy; gold-plated
7024240
UE48-2OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
Internal circuitry
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain open. If the connected sensor is not activated or the protective field of the connected optoelectronic protective device is not broken (i.e. the input circuits are closed), then the normally open contacts close immediately in automatic reset, LED K1 and K2 illuminate. In the case of manual resetting, this only occurs after pressing and releasing the reset button. The activation of the sensor or incursion into the protective field of the non-contact safety device (open state of one of the two input circuits) effects the opening of the normally open contacts (LED K1 and K2 off).
External device monitoring (EDM) The unit can take over external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts. Manual reset For manual resetting, a pushbutton must be connected to terminals S33 - S34. This reset is monitored. Automatic reset For ESPEs: S33 - S35 must be linked For applications with potential free contacts on the input circuit S12 - S35 must be linked. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity.
N - 44
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE48-2OS
Dimensional drawings
82.5 63 78 58
A B C D
93.7 114
107.6
93.6
114
107.6
E F G
75.3
93.3 96.5
93.3 96.5
22.5
22.5
H I J K L M N O P Q
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 45
UE48-2OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Connection diagrams
Safety light curtain C4000 Basic to UE48-2OS safety relay
+ 24 V
1 3 4 5 6 2 FE n.c 0V FE 1 5 6 3 4 2 FE
S33 S11 S12 S31 A1 13 23 31
S1
C4000S
C4000E
k1 k2
UE48-2OS
S34 S35 S21 S22 A2 14 24 32
K1 0V
K2
Operating mode: with manual reset and external device monitoring (EDM)
Safety light curtain C4000 Standard / Advanced light curtain connected to UE48-2OS safety relay
+24V
1 3 4 5 6 2 FE
1 5 6 3 4 2 FE
S33 S11S12 S31 A1 13 23 31
k1 k2 x y z k1 k2 z
C4000S
C4000R k1 k2
UE48-2OS2D2
S34 S35 S21S22 A2 14 24 32
K1 0V PELV
K2
Operating mode: with manual reset and external device monitoring (EDM)
N - 46
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE48-2OS
A
S1
x y k1 k2 x y z k1 k2 z
+24V
B C D E F G H I J K L M N O P Q
k1 k2
k1 k2
S0
S0
UE48-2OS2D2
S34S35 S12 S22 A2 14 24 32
K1 0V
K2 0V
K1
K2
Operating mode: with manual reset and external device monitoring (EDM)
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 47
UE48-3OS
UE48-3OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2 N-51
For
Product description
Cross
circuit detection on dual-channel wired systems 3 LEDs: Supply voltage Relay K1 Relay K2
Manual
reset reset Increase in the number of outputs by way of the expansion modules UE10-4XT UE11-4DX External device monitoring (EDM) Available with plug-in terminals (key coded)
Automatic
Applications
or
or
emergency stops For safety switches For safety laser scanners For safety light curtains For non-contact safety switches For pressure sensitive mats in accordance with EN 1760 using 4-wire technology 3
or
OSSD 1
OSSD 2
OS SD 1
OS SD
EDM
or
Compact
N - 48
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE48-3OS
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE48-3OS2D2 UE48-3OS3D2 Part number 6025089 6025097
A B C
PELV PELV or SELV 4 0 24 V AC/DC (20.4 V AC/DC ... 26.4 V AC/DC) AC mode DC mode 4.6 VA 2.1 W 2.4 VSS 50 Hz ... 60 Hz
D E F G H I J K L M N
Continued on next page
Residual ripple in DC mode (within the limits of VS) Nominal frequency in AC mode
O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 49
UE48-3OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 DIN EN 61000-6-4 DIN EN 61000-6-2 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
N - 50
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE48-3OS
Internal circuitry
A1 A2 S33 S34 S35 13 23 33
A B C D
14 24 34 K1
K2
SUPPLY
+
S21 S11 S12 S33 S31 S22
Function After applying the supply voltage (LED SUPPLY illuminates), the normally open contacts remain open. If the connected sensor is not activated or the protective field of the connected optoelectronic protective device is not broken (i.e. the input circuits are closed), then the normally open contacts close immediately in automatic reset, LED K1 and K2 illuminate. In the case of manual resetting, this only occurs after pressing and releasing the reset button. The activation of the sensor or incursion into the protective field of the non-contact safety device (open state of one of the two input circuits) effects the opening of the normally open contacts (LED K1 and K2 off).
External device monitoring (EDM) The unit can take over external device monitoring. The contactor monitoring system monitors the external relays by way of their normally closed contacts. Manual reset For manual resetting, a pushbutton must be connected to terminals S33 - S34. This reset is monitored. Automatic reset For ESPEs: S33 - S35 must be linked. For applications with potential free contacts on the input circuit S12 - S35 must be linked. Cross circuit detection Cross circuit is detected on dual-channel wired systems, if these are wired with opposing polarity.
E F G H I J K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 51
UE48-3OS
Safety relays
A B C D E F G H I J K L M N O P Q R
Dimensional drawings
82.5 63 78 58
107.6
107.6
93.6
114
75.3
93.3 96.5
93.3 96.5
22.5
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
Connection diagrams
Connection diagrams see safety relay UE48-2OS starting on page N-46
N - 52
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
22.5
7024240
93.7
114
Safety relays
A B C D E F
Muting
4 (EN 954-1)
Product description
UE49 muting modules are intended for use on: Electrosensitive protective equipments (ESPE) with monitored active switching outputs (OSSD), two-channel, complying with EN 61496-1. They enable protective operation with or without the muting function. In protective operation with muting, the muting module differentiates between conveyed goods and persons. The ESPE permits certain objects to penetrate into the hazardous area without the dangerous movement being switched off, whereas persons are excluded. The operating modes are selected using a rotary switch. In all operating modes, there is detection of wire breakage at the ESPE connections, and detection, with visual signal, of over and low voltage is also available. In addition, there is a connection for a monitored reset button.
module for electrosensitive protective equipment (ESPE) Meets requirements up to category 4 according to EN 954-1 Connection of 2 resp. 4 muting sensors Integrated override function Automatic reset Manual reset Muting functions by operating mode selector switch
G H I J K L M N O P Q R
Applications
You can find more applications using the application finder at www.sickusa.com/applications
Automotive Robotic Machining Palletizers
industry
Packaging Stone
centres
Further information
Page
Internal circuitry
N-55
7024240
N - 53
Safety relays
A B C D E F G H I J K L M N O P Q R
Ordering information
Number of enable current paths 2 3 Number of signalling current paths 1 Model Name UE49-2MM3D3 UE49-3MM3D3 Part number 6025098 6025099
1200 switching cycles/h 6A GL (EN 60947-5-1), C 8 A 1 x 107 switching cycles switching cycles (to AC 15 at 2 A, 230 V AC) III
N - 54
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
Internal circuitry
UE49-2MM3D3
A1+ A2 S12 S14 S21 S22 S24 S23 S31 S32 S34 S33 S41 S42 S44 S43 M1 M2 13 23 31
A
UE49-3MM3D3
A1+ A2 S12 S14 S21 S22 S24 S23 S31 S32 S34 S33 S41 S42 S44 S43 M1 M2 13 23 33
B C D E
PTC
Galvanic isolation K1
PTC
Galvanic isolation K1
K2
K2
K1
K1
run1
K2
K2
run2
K1
K1
run1
K2
K2
run2
48
58
X44
14 24 32
48
58
X44
14 24 34
Function UE49-2MM and UE49-3MM muting modules meet safetyspecific requirements up to category 4 (EN 954). Connected command units and safety sensors, subsequent controls, their wiring and installation must also comply with this category as defined in EN 954. The muting function is employed when certain objects, e.g. material pallets, are permitted to pass into the hazardous area. For the duration of this transport through the safety light beams, it suppresses monitoring by the ESPE. For the period during which the material is being transported, muting sensors detect its presence. By careful choice of the type of sensors and their arrangement, it is possible to distinguish between objects and persons. To this end, two or four muting sensors can be connected to the muting module. As it interacts with the muting sensors and ESPE, the conveyed object produces a precisely-defined signal sequence as it
passes the hazardous area. So as to ensure that the entry of a person to the ESPE will always result in the dangerous movement being switched off, it must not be possible for a person to generate the same signal sequence as a conveyed object. During the muting condition, the muting lamp, which is monitored by the device, is illuminated. The maximum permitted duration of the muting condition can be set in steps between 10 seconds and 8 hours, or be completely deactivated. During the muting cycle, an error in the sequence of muting signals or exceeding the permissible muting duration results in a FAULT. A release by pressing the reset button is only permitted when the muting sensors are quiescent, the muting lamp is not defective, and the ESPE that is to be bypassed is free.
F G H I J K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 55
Safety relays
A B C E F G I J K L M N O P Q R H D
Dimensional drawings
84
45
118
Dimensions in mm
N - 56
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
LE20
LE20
A B C D E F G H I J K L M N
Further information Page
Product description
2
External
Functions
Restart
interlock External device monitoring (EDM) Self testing 7-segment diagnostic display
Applications
Hazardous area protection using the VS/VE18 and the LE20 on an automated guided vehicle (AGV)
Ordering information
Connection type Screw terminal connector Spring clamp terminal connector Enclosure rating IP 20 IP 65 IP 20 IP 65 Type LE20-2612 LE20-1612 LE20-2614 LE20-1614 Part number 1016503 1016500 1016505 1016499
O P Q R
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 57
LE20
Safety relays
A B C D E F G H I J K L M N O P Q R
Response time for test input Reset time Connecting cables Inputs: signal level on/off Test extern
Max. 30 ms Max. 50 ms 0.5 mm2, length max. 30 m 2.5 mm2, length max. 150 m HIGH: 15 V ... VS LOW: 0 V ... 10 V HIGH: external test inactive LOW: external test active Pulse duration > 30 ms 2s
Outputs
Outputs OSSD 1, OSSD 2 (the levels refer to connection to the system connector) Switching current Imax Switching voltage Vmax Switching capacity Pmax Inductive switching capacity Pmax ind Protective field free V Protective field interrupted V Residual current at signal level "0" I Max. capacitive load PNP, monitored and short-circuit-proof 500 mA VS 2.0 V at 500 mA 13.2 W 1 VA Vmax 0V 0.1 mA 200 nF at I: 50 mA 2.5 F at I: 500 mA 2s 150 s approx. VS 2.65 V/0 V Total current Test A + Test B < 10 mA Max. capacitive load 10 F
Test period test rate Test pulse width Test A, Test B (inactive/active)
N - 58
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
LE20
Operating data
Protection class Enclosure rating Type according to EN 61496 Ambient operating temperature Storage temperature Air humidity (non condensing) Vibration resistance Shock resistance
1)
III 2) IP 20, IP 65 optional Type 2 20 C ... +60 C 25 C ... +75 C 15 % ... 95 % 5g, 10 Hz ... 55 Hz according to IEC 60068-2-6 10 g, 16 ms according to IEC 60068-2-29
A B C D E F G H I J K L M N O P Q
The upper and lower supply voltage limits must not be infringed. The external voltage supply to the devices must be capable of withstanding a short-term power failure of 20 ms in accordance with EN 60204. Suitable power supply units are available from SICK as accessories The circuits connected to the inputs and outputs must conform to the creepage and clearance distances specified in the relevant standards with regard to safe isolation in accordance with PELV (EN 60204, 6.4)
2)
Internal circuitry
LE20
STATUS OSSD OFF RESTART OSSD ON CODE POWER IN SENSOR INPUT SENSOR OUTPUT
TEST EXTERN
EDM DISABLE
RES DISABLE
SENSOR A
SENSOR B
TEST/NON
+ 24 V DC
OSSD 1
15
10
11
12
13
14
16
The LE20 safety evaluation unit is able to carry out a periodic safety test of the connected photoelectric switches, and provides the photoelectric switch system with the additional reset interlock and external device monitoring safety functions.
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
OSSD 2
TEST A
TEST B
EDM
RES
0V
NC
NC
N - 59
LE20
Safety relays
A B D E F G H I J K L M N O P Q R C
Dimensional drawings
109.5
100.2
80.9
77
90.8 99.1
Dimensions in mm
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 60
7024240
Safety relays
LE20
173.7
A B C D E F
31 14 14 14 14 1414 14 25
80 121
146.7
PG13.5
203.5 226.5
PG7
G H I
Dimensions in mm
18 38.5 136
Mechanical dimensions, IP 65 housing for LE20
J K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 61
LE20
Safety relays
A B C D E F G H I J K L M N O P Q R
Connection diagrams
Safety relay LE20 with 4 single-beam photoelectric safety switches WS/WE27-2, WS/WE18-2 or WS/WE12-2
+24 V 1) x
POWER IN
TEST EXTERN +24 V DC SENSOR A
SENSOR
SENSOR B TEST/NON
INPUT
EDM DISABLE RES DISABLE
SENSOR
OUTPUT
k1 x y z k1 k2
ODSS1
10
11
12
13
14
15
16
ODSS2
TEST B
TEST A
EDM
R ES
0V
NC
NC
k1 kT S1 k2
+ Q _ WE X WS X
+ T _
+ Q _ WE X WS X
+ T _
+ Q _ WE X 0V WS X
+ T _
+ Q _ WE X WS X
+ T _
K1
K2
These contacts must be integrated into the control system such that when the output circuit is open the hazardous state is eliminated.
In safety categories 4 and 3 they must be integrated in twochannel configuration (x, y paths). Single-channel insertion into the control system (z path) is only possible with single-channel control and taking account of the risk analysis.
N - 62
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
LE20
A B C D E F G H I J K L
Type UE10-2OS2DO UE10-2OS4DO Part number 2019772 2019771
OUTPUT k1 x
ODSS1 ODSS2 TEST B
LE20
POWER IN
TEST EXTERN +24 V DC SENSOR A
SENSOR
SENSOR B TEST/NON
INPUT
EDM DISABLE RES DISABLE
SENSOR
y z
TEST A
EDM
R ES
0V
NC
NC
k1 k2
10
11
12
13
14
15
16
k1 kT S1 k2 K1 0V PELV K2
TEST
0V
SEL 1
SEL 1
SEL 2
SHIELD
SEL 2
0V
24 V
NC
OSSD 1
C2000R
8
OSSD 2
C2000S
8
C2000R
8
C2000S
8
C2000R
C2000S
These contacts must be integrated into the control system such that when the output circuit is open the hazardous state is eliminated.
In safety categories 4 and 3 they must be integrated in twochannel configuration (x, y paths). Single-channel insertion into the control system (z path) is only possible with single-channel control and taking account of the risk analysis.
SHIELD
24 V
M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 63
LE20 Muting
LE20 Muting
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-66
Muting Restart External Self
Product description
2
OSSDs, PNP, monitored and shortcircuit protected External test pulse not required Functions individually selectable
Up
to 4 muting inputs, sensor or PLC signals possible Muting monitoring functions: sequence and concurrence operation possible Integrated override function
Applications
Ordering information
Internal circuitry
Connection type Screw terminal connector Spring clamp terminal connector Enclosure rating IP 20 IP 65 IP 20 IP 65 Type LE20-2622 LE20-1622 LE20-2624 LE20-1624 Part number 1016502 1016498 1016501 1016497
N - 64
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
LE20 Muting
A B C D E F G H I J K L M
Continued on next page
Response time for test input Reset time Connecting cables Inputs: signal level on/off Test extern
Max. 30 ms Max. 50 ms 0.5 mm2, length max. 30 m 2.5 mm2, length max. 150 m HIGH: 15 V ... VS LOW: 0 V ... 10 V HIGH: external test inactive LOW: external test active Pulse duration > 30 ms Time window selectable: 3 s or 2s
Outputs
Outputs OSSD 1, OSSD 2 (the levels refer to connection to the system connector) Switching current Imax Switching voltage Vmax Switching capacity Pmax Inductive switching capacity Pmax ind Protective field free V Protective field interrupted V Residual current at signal level "0" I Max. capacitive load PNP, monitored and short-circuit-proof 500 mA VS 2.0 V at 500 mA 13.2 W 1 VA Umax 0V 0.1 mA 200 nF bei I = 50 mA 2.5 F bei I = 500 mA 2s 150 s approx. VS 2.65 V/0 V Total current Test A + Test B < 10 mA Max. capacitive load 10 F 24 V DC, 1 ... 10 W 24 V DC, 1 ... 10 W
Test period test rate Test pulse width Test A, Test B (inactive/active)
N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 65
LE20 Muting
Safety relays
A B C D E F G H I J K L M N O P Q R
Operating data
Protection class Enclosure rating Type according to EN 61496 Ambient operating temperature Storage temperature Air humidity (non condensing) Vibration resistance Shock resistance
1)
III 2) IP 20, IP 65 optional Type 2 20 C ... +60 C 25 C ... +75 C 15 % ... 95 % 5g, 10 Hz ... 55 Hz according to IEC 60068-2-6 10 g, 16 ms according to IEC 60068-2-29
The upper and lower supply voltage limits must not be infringed. The external voltage supply to the devices must be capable of withstanding a short-term power failure of 20 ms in accordance with EN 60204. Suitable power supply units are available from SICK as accessories The circuits connected to the inputs and outputs must conform to the creepage and clearance distances specified in the relevant standards with regard to safe isolation in accordance with PELV (EN 60204, 6.4)
2)
Internal circuitry
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18
BIT 1
BIT 2
Intercon. +
Intercon. +
Intercon. +
Intercon. +
SEQUENCE
M1 M2 M3 M4 INPUT
Intercon. +
CONFIG.
TIME SELECT
CONCURR.
OUTPUT STATUS
OSSD OFF RESTART OSSD ON CODE POWER IN SENSOR INPUT SENSOR OUTPUT
LE20
TEST EXTERN
EDM DISABLE
RES DISABLE
SENSOR A
SENSOR B
OVERRIDE
TEST/NON
+ 24 V DC
OSSD 1
15
LAMP 1
16
10
11
12
13
14
The LE20 safety evaluation unit is able to carry out a periodic safety test of the connected photoelectric switches, and provides the photoelectric switch system with the additional reset interlock and external device monitoring safety functions.
OSSD 2
TEST A
TEST B
EDM
RES
0V
The expanded LE20 Muting version uses additional muting sensors to distinguish objects entering the hazardous area past the photoelectric switches from human beings, and allows the objects to pass without stopping the machine.
N - 66
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
LE20 Muting
Dimensional drawings
A B
90.8
C D E F
121.2
109.5
100.2
84.8
G H
Dimensions in mm
I J
Continued on next page
K L M N O P Q
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 67
LE20 Muting
Safety relays
A B C D E F G H I
PG13.5
173.7
80 121
146.7
PG7
14 14 14 14 1414 14 25
31
18
J K L M N O P Q R
N - 68
Mechanical dimensions, IP 65 housing for LE20 Muting
38.5 136
Dimensions in mm
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
203.5 226.5
7024240
Safety relays
LE20 Muting
Connection diagrams
Safety relay LE20 Muting with C2000, 2 muting sensors and 2 muting indicator lamps
+24 V
A B
1) X Y
C D E F G H
32
M1
31
M2
30
M3
29
M4
28
Interconn+
27
BIT1
26
BIT2
25
Interconn+
24
Interconn+
23
SEQUENCE
22
CONCURR.
21
Interconn+
20
Interconn+
19
LAMP 2
18
LAMP 1
+ Q
k1
k2 X Y Z
LE20
INPUT POWER IN
TEST EXTERN
A1 OUTPUT OUTPUT
OVERRIDE LAMP
+ Q
k1
A2
SENSOR B
SENSOR A
k2
OSSD1 OSSD2
TEST/NON
OVERRIDE
10
11
12
13
TEST B
TEST A
+24 V
EDM
RES
0V
14
15
16
I J K L M N O P Q
CR2000
CS2000
These contacts must be integrated into the control system such that when the output circuit is open the hazardous state is eliminated.
In safety categories 4 and 3 they must be integrated in twochannel configuration (x, y paths). Single-channel insertion into the control system (z path) is only possible with single-channel control and taking account of the risk analysis.
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 69
LE20 Muting
Safety relays
A B C D E F G H I J K L M N O P Q R
1) 32
M1
31
M2
30
M3
29
M4
28
Interconn+
27
BIT1
26
BIT2
25
Interconn+
24
Interconn+
23
SEQUENCE
22
CONCURR.
21
Interconn+
20
Interconn+
19
LAMP 2
18
LAMP 1
k1
+ Q + Q
k2 X Y Z
LE20
INPUT POWER IN
TEST EXTERN SENSOR A
CONFIG. SENSOR
SENSOR B
INPUT
EDM DISABLE
OUTPUT OUTPUT
OVERRIDE LAMP
A1
+ Q
B1 k1 k2
A2
OSSD1 OSSD2
TEST/NON
OVERRIDE
10
11
12
13
TEST B
TEST A
+24 V
EDM
RES
0V
14
15
16
11
M2000-A/P
These contacts must be integrated into the control system such that when the output circuit is open the hazardous state is eliminated.
In safety categories 4 and 3 they must be integrated in twochannel configuration (x, y paths). Single-channel insertion into the control system (z path) is only possible with single-channel control and taking account of the risk analysis.
Connection type
Delivery/cable length
N - 70
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE10-4XT
UE10-4XT
A B C D E F G
Expansion External
Product description
The
UE10-4XT expansion module serve to: Increase the number of output contacts of a main unit N/C contact for external device monitoring (EDM)
Ordering information
Connection type Screw-type terminals Plug-in terminals Type UE10-4XT2D2 UE10-4XT3D2 Part number 6024919 6024920
(EDM)
H I J K L M N
4 2
Further information
Page N-2
Symbols
O P Q R
A-2
7024240
N - 71
UE10-4XT
Safety relays
A B C D E F G H I J K L M N O P Q R
Output circuits (13 - 14, 23 - 24, 33 - 34, 43 - 44, 51 - 52, 61 - 62, Y1 - Y2)
Response time (K1 / K2) Relay contacts 40 ms 4 N/O, enable current paths, safety relevant 2 N/C, signalling current paths, not safety relevant 1 N/C, contactor monitoring Positively guided Silver alloy; gold-plated Switching voltage enable current paths Switching voltage contactor monitoring Switching current enable current paths Switching current signalling current paths Switching current contactor monitoring Total current across all contacts Application category according to EN 60947-5-1 10 V AC ... 230 V AC / 10 V DC ... 30 V DC 10 V DC ... 24 V DC 10 mA ... 6 A 10 mA ... 2 A 10 mA ... 0.1 A 12 A AC-15 Ue 230 V AC, Ie 6 A (3600 c/h) DC-13 Ue 24 V DC, Ie 6 A (360 c/h) DC-13 Ue 24 V DC, Ie 3 A (3600 c/h) 3600 c/h 1 x 107 switching cycles 2 x 106 switching cycles
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 EN 60947-1 02/99 EN 60947-1 02/99 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 72
7024240
Safety relays
UE10-4XT
Internal circuitry
A1 A2 Y1 13 23 33 43 51 61
A B C D
Y2 14 24 34 44 52 62
K1 K2
Function The supply voltage of the expansion module is linked to an output contact of a main unit. Upon applying the supply voltage to terminals A1 and A2, relays K1 and K2 are energised (the LEDs for both relays illu-minate): The 4 ouput contacts close, the two normally closed contacts and the EDM (feedback) circuit switch to open circuit status.
When the output contacts of the standard unit opens (e.g. by activation of the emergency stop), the relays K1 and K2 deenergise: The normally open contacts open, and the two normally closed contacts close. External device monitoring (EDM) If external device monitoring is implemented in the connected main unit, then the normally closed contacts (Y1 - Y2) prevent the resetting of the main unit, when K1 and/or K2 do not deenergise.
E F G H I J K
Dimensional drawings
82.5 63 78 58
107.6
107.6
93.6
114
93.7
114
75.3
L M N
93.3 96.5
93.3 96.5
22.5
22.5
O P Q R
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 73
UE11-4DX
UE11-4DX
Safety relays
A B C D E F G H I J K L M N O P Q R
Further information Page N-2 N-76
Expansion
Product description
The
UE11-4DX expansion module serve to: Increase the number of output contacts of a main unit UE11-4DX has off-delayed outputs (0.5 s, 1 s, 2 s or 3 s, depending on model) N/C contact for external device monitoring (EDM)
Ordering information
N - 74
7024240
Safety relays
UE11-4DX
A B C D E F G H I J K L M N O P Q
N - 75
Output circuits (17 - 18, 27 - 28, 37 - 38, 47 - 48, 55 - 56, 65 - 66, Y1 - Y2) off-delayed
Switch-off delay time (depending on type) Influence of the supply voltage Influence of ambient temperature Mean value of error (% + 10 ms) Dispersion (% + 10 ms) Relay contacts 0.5 s, 1 s, 2 s or 3 s 0.5 (%/% UN) 0.4 (%/K) 20 2 4 N/O, enable current paths, safety relevant 2 N/C, signalling current paths, not safety relevant 1 N/C, contactor monitoring Positively guided Silver alloy; gold-plated Switching voltage enable current paths Switching voltage contactor monitoring Switching current enable current paths Switching current signalling current paths Switching current contactor monitoring Total current across all contacts Application category according to EN 60947-5-1 10 V AC ... 230 V AC / 10 V DC ... 30 V DC 10 V DC ... 24 V DC 10 mA ... 6 A 10 mA ... 2 A 10 mA ... 0.1 A 12 A AC-15 Ue 230 V AC, Ie 6 A (3600 c/h) DC-13 Ue 24 V DC, Ie 6 A (360 c/h) DC-13 Ue 24 V DC, Ie 3 A (3600 c/h) 3600 c/h 1 x 107 switching cycles 2 x 106 switching cycles
Permitted switching frequency Service life, mechanical (relay contacts) Service life, electrical (dependent on the load)
Operating data
Surge voltage rating (UImp.) Excess voltage category Contamination rating of the unit (EN 50178) External Internal Voltage rating Test voltage Ueff (50 Hz) EN 60439-1 Enclosure rating Housing Terminals Radio interference Screening against interference Ambient operating temperature Storage temperature Wire cross-sections Single strand wire (2 x, identical cross section) Single strand wire (1 x) Fine stranded wire with terminal crimps (2 x, identical cross section) Fine stranded wire with terminal crimps (1 x) IP 40 IP 20 EN 60947-1 02/99 EN 60947-1 02/99 25 C ... +55 C 25 C ... +75 C 0.14 mm2 ... 0.75 mm2 0.14 mm2 ... 2.5 mm2 0.25 mm2 ... 0.5 mm2 0.25 mm2 ... 2.5 mm2 3 2 300 V AC 2.0 kV 4 kV III
Weight
0.2 kg
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
UE11-4DX
Safety relays
A B C D E F G H I J K L M N O P Q R
Internal circuitry
A1 A2 Y1 17 27 37 47 55 65
K1
K2
Y2
18 28
38 48 56 66
Function The supply voltage of the expansion module is switched by way of a output contact of a standard unit. Upon applying the supply voltage to terminals A1 and A2, relays K1 and K2 are energised (the LEDs for both relays illu-minate): The 4 output contacts close, the two normally closed contacts and the EDM (feedback) circuit switch to open circuit status. When the output contacts of the standard unit opens (e.g. by activation of the emergency stop switch), the relays K1 and K2 de-energise after a unit specific delay. These fixed switch-off delay times of 0.5 s, 1 s, 2 s and 3 s are according to the type.
This is achieved by means of capacitors, so that even in the event of power supply failure the off-delay runs it full duration in each instance. Only after the delay period has expired do the relays K1 and K2 return to their neutral rest position. With the combination of UE11-4DX (with off-delayed) and a standard unit, stop category 1 (EN 418) can be realised. External device monitoring (EDM) If external device monitoring is implemented in the upstream installed standard unit, then the normally closed contacts (Y1 - Y2) prevents the resetting of the standard unit, when K1 and/or K2 do not de-energise.
N - 76
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
7024240
Safety relays
UE11-4DX
Dimensional drawings
82.5 63 78 58
A B C D E F G
22.5
107.6
107.6
93.6
114
75.3
93.3 96.5
93.3 96.5
93.7
114
22.5
H I J K L M N O P Q
48.3 66.7
Housing with screw-type terminals Housing with plug-in terminals
57 85
Dimensions in mm
7024240
SICK, Inc., USA. All rights, including changes to technical specifications and or to the equipment without prior notification, are reserved.
N - 77