Documente Academic
Documente Profesional
Documente Cultură
APN 2004
The adixen Pirani gauge APN 2004 with the standard Tungsten filament is a reliable and cost effective solution for general industral vacuum applications and also in research and development. Certain applications require a filament with improved resistance against corrosive gases. To address these applications adixen offers a new active Pirani gauge, the APN 2004.
PRODUCT BENEFITS
The APN 2004 is equipped with a filament made of Nickel (Ni) instead of the standard Tungsten (W) filament used on the AP 2004. Improved resistance in atmospheres with corrosive gases (except with high concentrations of Cl and F) Considerably longer filament lifetime in high water vapour environments Withstands sterilization processes in medical and pharmaceutical applications Can replace AP 2004 without modification of circuitry, including setpoints Fully integrated into the Series 2000 vacuum gauges family
APPLICATIONS
The APN 2004 is the best choice in all vacuum applications where the accuracy of a Pirani gauge is required but a Tungsten filament will suffer from corrosive gases or process by-product. Industrial drying processes outgassing of monomers or traces of acids Freeze drying - high water vapour content Sterilization - water vapour at high temperatures, Hydrogen peroxide Reactive sputtering - Oxygen plasma Fabrication of nano structures - Silicon and Carbon chemistry
APN 2004
ELECTRICAL SPECIFICATIONS
Power supply Voltage Consumption max. Analog output signal Measurement range Pressure signal Error Signal Minimum load Cable length max. Type of protection Set points Dry contacts (2) 1 A 30 VDC 24 VDC (14 - 30 VDC) (tolerance ripple : below 2 Vp-p) <1W 2.2 V - 8.5 V logarithmic 1 V / decade < 0.1 V or = 0.4 V 200 m (0.34 mm ) IP40 100 k
ENVIRONMENTAL SPECIFICATIONS
Temperature Storage Operation Bakeout Bakeout with high temp. O-Ring Pressure max. - 20 C / +70 C +5 C / +60 C < 150 C (without electronics) < 300 C (without electronics) 10 bar*
ORDERING INFORMATION
DN 16 ISO KF, Output 0 - 10 V with 2 set-points Compatible Controllers ACS 2000 single channel controller with numerical display ACM 2000 triple channel controller with graphical display Measuring cable 5 m -10 m - 20 m Accessories Filter DN 16 ISO KF 20 m
APN 2004
115 244 112711 112712 112751 112752 - 112753 305225
COMPATIBLE CONTROLLERS
ACS 2000 ACM 2000
www.adixen.com
China
Alcatel Vacuum Technology Shanghai Tel: (8621) 5027 0628 Fax: (8621) 3895 3815
France (Headquarters)
Alcatel Vacuum Technology France Tel: 33 (0)4 50 65 77 77 Fax: 33 (0)4 50 65 77 89
Germany
Alcatel Hochvakuum Technik GmbH Tel: (49) 9342 96 10 0 Fax: (49) 9342 96 10 30
India
Alcatel Vacuum Technology India Tel: (91) 124 473 7777 Fax: (91) 124 473 7799
Italy
Alcatel Vacuum Systems S.p.A. Tel: (39) 039 686 3855 Fax: (39) 039 667 125
Japan
Alcatel-Lucent Japan Ltd Tel: (81) 3 6431 7130 Fax: (81) 45 544 0049
Korea
Alcatel Vacuum Technology Korea Tel: (82) 31 206 6277 Fax: (82) 31 204 6279
Netherlands
Alcatel Vacuum Technology Netherlands Tel: (31) 345 478 400 Fax: (31) 345 531 076
Singapore
Alcatel-Lucent Singapore Tel: (65) 6254 0828 Fax: (65) 6254 7018
Sweden
Adixen Scandinavia Tel: (46) 13 35 59 00 Fax: (46) 13 35 59 01
Taiwan
Alcatel Vacuum Technology Taiwan Tel: (886) 3 5599 230 Fax: (886) 3 5599 231
United Kingdom
Alcatel Vacuum Technology (U.K.) Ltd Tel: (44) 1 506 418 000 Fax: (44) 1 506 418 002
USA
Alcatel Vacuum Products Tel: (1) 781 331 4200 Fax: (1) 781 331 4230
Publication: Alcatel Vacuum Technology - Part Number 791662 - 03/2009 - All information can be modified without prior notice.