GT IRRI-GATOR
Self-Priming Centrifugal Pumps 60 Hz FEATURES
Self-Priming Design: Once pump is initially primed, filled with water, it will reprime when the water level rises above the end of the suction pipe. Serviceable: Now available with an optional higher base. Back pullout design allows disassembly of pump for service without disturbing piping. Two compartment motor for easy access to motor wiring and replaceable components. Diffuser (Guidevane): Bolt down diffuser provides positive alignment with impeller. Diffuser has stainless wear ring for extended performance in abrasive conditions. F.D.A. compliant, injection molded, food grade, glass filled Lexan for durability and abrasion resistance. Impeller: F.D.A. compliant, glass filled Noryl. Corrosion and abrasion resistant. Corrosion Resistant: Electro-coat paint process is applied inside and out, then baked on. Casing: Cast iron construction. Four (4) bolt, back pull-out design. Tapped openings provided for vacuum gauge and casing drain. Powered for Continuous Operation: Pump ratings are within the motor manufacturers recommended working limits. Can be operated continuously without damage. Mechanical Seal: Carbon/ceramic faces, BUNA elastomers. 300 series stainless steel metal parts. Pump design prevents the seal from running dry.

IT T

www.goulds.com Goulds Pumps is a brand of ITT Corporation. Goulds Pumps is ISO 9001 Registered.

Goulds Pumps
Residential Water Systems
APPLICATIONS Specifically designed for the following uses: Lawn sprinkling Irrigation Air conditioning systems Heat pumps Water transfer Dewatering SPECIFICATIONS Pump: Pipe connections: 1 NPT suction 1 NPT discharge Capacities: to 110 GPM at 5 foot suction lift Heads: to 128 feet Reprime capabilities: to 25 feet suction lift Maximum working pressure: 125 PSIG Maximum water temperature: 140 F (60 C) Rotation: clockwise when viewed from motor end. Motor: NEMA standard open drip proof 60 Hz, 3500 RPM Stainless steel shaft Single phase: 1 HP, 115/230 V; 2 and 3 HP, 230 V only. Built-in overload with automatic reset. Three phase: 230/460 V. Overload protection must be provided in starter unit. Starter and heaters (3) must be ordered separately. Optional TEFC motors are available. See price book for order numbers. AGENCY LISTINGS

Canadian Standards Association Underwriters Laboratories

UL

STANDARD ODP MODELS


Model HP Phase GT07 GT10 1 GT15 1 1 GT20 2 GT30 3 GT073 GT103 1 GT153 1 3 GT203 2 GT303 3 Add on S suffix for extended base. See back page.

DIMENSIONS AND WEIGHTS


Model HP Length L Width Height Weight (lbs.) Phase GT07 19316 GT10 1 1978 GT15 1 21316 GT20 2 203132 GT30 3 211132 GT073 19 GT103 1 19 GT153 1 20116 GT203 2 201316 GT303 3 21316

48

52

60 Single

65

8 9 (13 with S Base) 76 49

52

55 Three

69

71

(All dimensions are in inches and weights in lbs. Do not use for construction purposes.)

1 NPT DISCHARGE 1 SUCTION

3 9 318

GT _ _ S with optional base

4916

3 8 PAGE 2

7 8

4916

518

Goulds Pumps
Residential Water Systems
PERFORMANCE CURVE
METERS FEET 40 120 TOTAL DYNAMIC HEAD (H)
25

30

100

25

25 20 20 20

80 20
25 20 25

15 15 20 10 15 10 15 10 5 GT20

60

40 10 20

15 10 5 GT07

10

5 GT10 5 GT15

5 GT30

0 0 0

10

20 5

30

40

50

60

70

80

90 20

100

110

120 U.S. GPM

10 15 GALLONS PER MINUTE (Q)

25 m3/hr.

Single and three phase have same performance.

PERFORMANCE RATINGS
Model GT07/ GT073 GT10/ GT103 GT15/ GT153 GT20/ GT203 GT30/ GT303 PSI Discharge Pressure 20 30 40 20 30 40 20 30 40 20 30 40 20 30 40 Suction Lift in Feet 5 44 34 10 53 43 29 63 60 45 86 80 65 105 92 73 10 41 31 4 51 41 22 59 55 38 77 72 60 100 90 67 15 36 26 0 49 38 16 54 51 33 70 67 57 88 84 62 20 31 22 0 46 36 8 49 46 20 59 57 50 76 75 55 25 24 14 0 41 32 0 39 37 14 46 44 43 60 57 50

SELF-PRIMING (AFTER INITIAL PRIME)

Water recirculates, but during re-priming operation only. Air is exhausted from suction line through discharge pipe.

Arrows show flow of water after all air has been exhausted from suction line.

Performance ratings are in GPM.

PAGE 3

COMPONENTS
Item No. 1 2 3 4 5 6 7 8 9A 9B 9C 10 11 12 13 14
Also available as a 15K86.

Description Plug NPT Casing Seal ring diffuser Diaphragm Machine screw Diffuser Impeller Mechanical seal Foot and 1 HP Base 1 HP and up Extended base S suffix Bolt foot to adapter Motor adapter Bolt casing to adapter Bolt adapter to motor Deflector

14 8 12 7 3 4 2 1 5 6 10 9A 11 1 13

9C 9B

9C Order by adding an S suffix, ex. GT07S. It is also sold as a 15K86 stand alone part.

2881 East Bayard Street, Seneca Falls, NY 13148 Phone: (315) 568-7123 Fax: (315) 568-7973 www.goulds.com

IT T

Goulds Pumps and Irri-gator are registered trademarks of ITT Corporation. ITT and the Engineered Blocks Symbol are registered trademarks of ITT Manufacturing Enterprises, Inc. Noryl and Lexan are registered trademarks of GE Plastic.
Copyright 2011 ITT Corporation BGT March, 2011 Printed in U.S.A. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.