iris diaphragm lever fine focus knob 7. An increase in magnification causes a decrease in the field of view. a decrease in the working distance. a decrease in the depth of field. all of the above. 8. Working distance is the distance from your house to your job. distance the microscope nosepiece travels using the coarse focus knob. distance from the bottom of the objective lens to the specimen. distance the specimen can travel across the microscope stage. 9. The magnification of a light microscope is limited to 1000X by the resolving power of the instrument. true false 10. When using the oil immersion lens, you should raise the objective lenses for easy application of an oil droplet to the slide. true false 11. Why must a small object seen through the ocular lens be centered in the field of view, before changing to a higher power objective lens? to prevent damage to the objective lens to compensate for the decrease in resolving power of the lens to prevent its disappearance due to the decrease in the field of view to prevent eyestrain 12. A parfocal microscope allows you to quickly focus using the low power or scanning lens and then, to switch to a higher power lens with only a minimal adjustment of the fine focus knob.
true false 13. Why is it necessary to adjust the amount of light after changing objective lenses? Higher magnification lenses require more light. Proper lighting is needed to see specimen details. The lens aperture decreases with higher magnification lenses. All of the above. 14. One meter equals 100 cm. 1000 mm. 1,000,000 microns. All of the above. 15. A grid slide (with 1 mm squares) is used to directly measure the field of view. the depth of field. the working distance. magnification. 16. If you prepare a wet mount slide and observe a large empty circle with dark edges, you are most likely seeing an air bubble. true false 17. If the field of view of the low power (10x) objective lens is 4 mm, what would the field of view be for the oil immersion (100x) lens? 400 microns 4 mm 0 .4 cm None of the above.
18. Depth of field is best demonstrated with a slide showing the letter e. a slide containing overlapping threads. a wet mount slide preparation. the oil immersion lens. 19. When the letter e slide is viewed with the microscope, it appears right side up. right side up and backwards. upside down. upside down and backwards. 20. A wet mount is a freshly prepared slide. a horse left out in the rain.