Documente Academic
Documente Profesional
Documente Cultură
Question No.
Question Body
Question 1.
Selection)
(769,Single
1. Normal source 2. Secondary source 3. Primary source 4. None of the above Wrong! Looking for answers(s):2
What is called that supplies power to the load only during the absence of power?
Explanation: Normal source is one which supplies power to the load round the clock and secondary source is one which supplies power to the load only during the absence of power from normal source
Question 2.
Selection)
(770,Single
1. Complete absence of rotary parts. Hence no wear and tear, Maintenance is easy, Long life. 2. Conversion efficiency is high. 3. Regulation is easy without involving any moving mechanism. 4. All of the above Wrong! Looking for answers(s):4
Explanation: Previously M.G (Motor-Generator) sets were used for A.C to D.C conversion. In this A.C motor rotates on commercial A.C. supply. To the shaft of this AC motor, D.C. Generator will be coupled which generates D.C
Question 3.
Selection)
(771,Single
1. Two phase, 2-wire, 50 Hz supply 2. Three phase, 4-wire, 50 Hz supply 3. Three phase, 3-wire, 50 Hz supply 4. Two phase, 4-wire, 50 Hz supply Wrong! Looking for answers(s):2
Question 4.
Selection)
(772,Single
1. 2.00v/cell
If the float rectifier output voltage is 51.5v, the cells are floated at
Question 5.
Selection)
(773,Single
1. at the top 2. at the bottom 3. left side 4. right side Wrong! Looking for answers(s):1
Question 6.
Selection)
(774,Single
1. thyristors 2. integrated circuits 3. transistors 4. Both 2 & 3 Wrong! Looking for answers(s):4
Question 7.
Selection)
(775,Single
Question 8.
Selection)
(776,Single
HT Voltage corresponds to
Question 9.
Selection)
(777,Single
1. Multi-rack configuration.
2. Facility to parallel a maximum of 21 nos. (or 22 nos.) of 100A (5600W) rectifier modules operation from three phase, 400V, 50Hz AC input. 3. Termination for three sets of VRLA batteries and exchange load. 4. All of the above Wrong! Looking for answers(s):4
Question 10.
Selection)
(778,Single
Question 11.
Selection)
(779,Single
Question 12.
Selection)
(780,Single
Question 13.
Selection)
(781,Single
To monitor AC input current, How many nos. of singlephase AC current transformers are mounted on the panel of main rack of SMPS power plant (ITI Make)
Question 14.
Selection)
(782,Single
Question 15.
Selection)
(783,Single
Question 16.
Selection)
(784,Single
1. reduces the switching losses of the power semiconductors 2. decreases the electromagnetic interference (EMI) 3. Both 1 & 2 4. None of the above Wrong! Looking for answers(s):3
Question 17.
Selection)
(785,Single
In SMPS (ITI make), Total harmonic distortion (THD) of the input current wave form is below
Question 18.
Selection)
(786,Single
1. auto float 2. auto charge 3. manual boost 4. All of the above Wrong! Looking for answers(s):4
Question 19.
Selection)
(787,Single
Power factor shall be greater than_____________lagging durin nomainal input,max output &load 25% to 100%
Question 20.
Selection)
(788,Single
Question 21.
Selection)
(789,Single
1. All reference voltages and protections to the sub-modules 2. Signalization and manual interface (adjustment potentiometers and test jacks) for the whole unit 3. Communication with power system controller 'ITI' 4. All of the above Wrong! Looking for answers(s):4
Question 22.
Selection)
(790,Single
1. balance load 2. imbalance load 3. Both 1 & 2 4. None of the above Wrong! Looking for answers(s):2
Question 23.
Selection)
(791,Single
Question 24.
Selection)
(792,Single
1. DC/DC Converter 2. Transformer 3. Snubber Circuit 4. None of the above Wrong! Looking for answers(s):1
The heart of the module(IN SMPS ITI make, single submodule R, S or T ) is the
Question 25.
Selection)
(793,Single
1. 1 X 230 Vac rms (with neutral wire) source 2. 2 X 230 Vac rms (with neutral wire) source 3. 3 X 230 Vac rms (with neutral wire) source 4. None of the above Wrong! Looking for answers(s):3