Sunteți pe pagina 1din 5

Software exchange for the TNC 426 CB/PB, TNC430 CA/PA and the TNC 426 M and TNC

430 M with EPROMs (Id. Nr. 324 990-xx to 324 997-xx). The procedure for software exchange on the TNC 426 M and TNC 430 M with flash EPROMs (Id.-Nr. 344 958-xx to 344 965-xx) is described later in this document. ============================================================================ The NC operating software of the TNC426/TNC430 is located on EPROMs. System files, the language and cycle files and all other files are saved on hard disk. To exchange the software on the TNC426/TNC430 you receive an EPROM kit and floppy disks with new language and cycle files(saved in compressed format in the files SETUP.BCK, SETUP.LST). These floppy disks also contain a data transfer program (TNCBACK.EXE) and the files SETUP.BAT and SETUP32.BAT, which calls the data transfer program with the correct parameters. This enables you to transfer the new language and cycle file over the serial interface or Ethernet (only with SETUP32.BAT) to the control. One floppy disk also includes a description of the machine parameters for the new software level (LIES_MP.A or READ_MP.A file). Data transfer is in LSV2 protocol and is started from the PC by entering SETUP or SETUP32 after the DOS prompt. Use SETUP for the operating systems Windows 3.1 and Windows for Workgroups 3.11. Use SETUP32 for the operating systems Windows 95, 98 and NT. Data transfer over the serial interface: You define the interface by entering a parameter after the SETUP or SETUP32 command, separated by a space. The parameter value 1 indicates the interface COM1, the value 2 indicates COM2, etc. The baud rate adjusts itself automatically to the baud rate of the control. Example: COM2: SETUP 2 or SETUP32 2 Data transfer over Ethernet: Data transfer via Ethernet is possible only with SETUP32. The IP address of the TNC is entered after the command SETUP32, separated by a space. Example: SETP32 160.1.180.21 In both cases, transmission can be canceled with ESC. Please proceed as follows to exchange the software: ======================================================= ************************************************************************* * CAUTION: The software must be exchanged only by properly * * trained personnel! * ************************************************************************* - ************************************************************************* * Note: If customized (OEM) cycles are saved on the TNC, read-out the * * cycle structure with cycle design. For detailed information, * * refer to the CycleDesign documentation. * * * * If you are updating from software 280 470-xx to 280 472-xx, * * 280 474-xx or 280 476-xx and there are OEM cycles on the TNC, *

* after exchanging the EPROM you must retransfer the OEM cycle * * with CycleDesign to the TNC. With the introduction of software * * 280 472-01 the format of the cycle system file was changed. * * * * If you are updating to software 280 474-04 or later, you should * * save your cycle project as a separate OEM project. This makes * * you independent of future changes in the standard HEIDENHAIN * * cycle structure. Refer to the CycleDesign-Documentation! * ************************************************************************* - In the Programming and Editing mode, press the MOD key. - Enter the code number 95148. - Press the MOD key. - Press the UPDATE DATA soft key. - Press the CONVERT BIN=>ASC soft key. This converts all files into ASCII format. Before conversion, free data storage space must be at least half a large as the amount of space already occupied. If you need more space, you can move files temporarily to the PC (e.g. with TNCremo, TNCremoNT or TNCBACK.EXE). - Switch off the control. - Exchange the EPROMs. Replace the EPROMs IC1 to IC6 (see sockets) with the new ones. Ensure the correct mounting position of the EPROMs. +-------------------------------------------+ Sockets on processor board for LE426 CB/PB LE430 CA/PA +-------+ +-------+ IC5 IC6 +-------+ +-------+ +-------+ +-------+ IC3 IC4 +-------+ +-------+ +-------+ +-------+ +-------+ ICS IC1 IC2 +-------+ +-------+ +-------+ +-------------------------------------------+ +--------------------------------------+ Sockets on processor board for LE426 M LE430 M

+-------+ +-------+ IC5 IC6 +-------+ +-------+ +-------+ +-------+ IC3 IC4 +-------+ +-------+ +-------+ +-------+ IC1 IC2 +-------+ +-------+ +--------------------------------------+ ************************************************************************* * CAUTION: Ensure compliance with the precautionary measures against * * electrostatic discharge (ESD) described in EN 100 015. * ************************************************************************* - Switch on the control. - Add or delete machine parameters. For information on the machine parameters, refer to READ_MP.A or LIES_MP.A. - To exit the machine parameters, press the END key. The message LANGUAGE LOAD ERROR appears. - At the PC, enter SETUP or SETUP32 to transfer the language and cycle files. After the files have been transferred, the control performs a reset. - ************************************************************************* * CAUTION: If customized (OEM) cycles are saved on the TNC, use * * CycleDesign to transfer the cycle structure to the TNC. * * Refer also to the CycleDesign documentation. * ************************************************************************* - In the Programming and Editing mode, press the MOD key. - Enter the code number 95148. - Press the MOD key. - Press the UPDATE DATA soft key. - Press the soft key CONVERT ASC=>BIN to restore the files. - Restore the temporarily saved files from the PC. - End of software exchange. - With the COPY SAMPLE FILES soft key, the cutting data tables, the tilting-axis geometry table and the table of M-function macros are copied to the corresponding folders. **************************************************************************** ****************************************************************************

Software exchange for the TNC 426 M and TNC 430 M with flash EPROMs (Id. Nr. 344 958-xx to 344 965-xx) ============================================================================ The NC operating system software of the TNC426 M/TNC430 M with the abovementioned ID number is supplied on flash EPROMs. The system files, language files, cycle files, and all other files are saved on the hard disk. To exchange the software on the TNC426/TNC430 with flash EPROMs, you receive data with the files SETUP.BCK and SETUP.LST. The data also include a data transfer program (TNCBACK.EXE) and the files SETUP.BAT and SETUP32.BAT. This enables you to transfer the new language and cycle file over the serial interface or Ethernet to the control. The data also include a description of the machine parameters for the new software level (file names LIES_MP.A and READ_MP.A). Data transfer is in LSV2 protocol and is started from the PC by entering SETUP or SETUP32 after the DOS prompt. Use SETUP for the operating systems Windows 3.1 and Windows for Workgroups 3.11. Use SETUP32 for the operating systems Windows 95, 98 and NT. Data transfer over the serial interface: You define the interface by entering a parameter after the SETUP or SETUP32 command, separated by a space. The parameter value 1 indicates the interface COM1, the value 2 indicates COM2, etc. The baud rate adjusts itself automatically to the baud rate of the control. Example: COM2: SETUP 2 or SETUP32 2 Data transfer over Ethernet: Data transfer via Ethernet is possible only with SETUP32. The IP address of the TNC is entered after the command SETUP32, separated by a space. Example: SETP32 160.1.180.21 In both cases, transmission can be canceled with ESC. Please proceed as follows to exchange the software: ======================================================= ************************************************************************* * CAUTION: The software must be exchanged only by properly * * trained personnel! * ************************************************************************* - ************************************************************************* * Note: If customized (OEM) cycles are saved on the TNC, read-out the * * cycle structure with cycle design. For detailed information, * * refer to the CycleDesign documentation. * * * * If you are updating from software 280 470-xx to 280 472-xx, * * 280 474-xx or 280 476-xx and there are OEM cycles on the TNC, * * after exchanging the EPROM you must retransfer the OEM cycle * * with CycleDesign to the TNC. With the introduction of software *

* 280 472-01 the format of the cycle system file was changed. * * * * If you are updating to software 280 474-04 or later, you should * * save your cycle project as a separate OEM project. This makes * * you independent of future changes in the standard HEIDENHAIN * * cycle structure. Refer to the CycleDesign-Documentation! * ************************************************************************* - In the Programming and Editing mode, press the MOD key. - Enter the code number 95148. - Press the MOD key. - Press the UPDATE DATA soft key. - Press the CONVERT BIN=>ASC soft key. This converts all files into ASCII format. Before conversion, free data storage space must be at least half a large as the amount of space already occupied. If you need more space, you can move files temporarily to the PC (e.g. with TNCremo, TNCremoNT or TNCBACK.EXE). - On the PC, enter SETUP or SETUP32 to transfer the new NC software to the control. After the files have been transferred, the control performs a reset. - Add or delete machine parameters. For information on the machine parameters, refer to READ_MP.A or LIES_MP.A. - To exit the machine parameters, press the END key. The message LANGUAGE LOAD ERROR appears. - ************************************************************************* * CAUTION: If customized (OEM) cycles are saved on the TNC, use * * CycleDesign to transfer the cycle structure to the TNC. * * Refer also to the CycleDesign documentation. * ************************************************************************* - In the Programming and Editing mode, press the MOD key. - Enter the code number 95148. - Press the MOD key. - Press the UPDATE DATA soft key. - Press the soft key CONVERT ASC=>BIN to restore the files. - Restore the temporarily saved files from the PC. - End of software exchange. - With the COPY SAMPLE FILES soft key, the cutting data tables, the tilting-axis geometry table and the table of M-function macros are copied to the corresponding folders.