Sunteți pe pagina 1din 8

T6COMPACT+

10kVA - 40kVA

T6COMPACT+
10kVA - 40kVA
The T6 Compact+ is designed to protect against the many electrical threats which stalk our heavily computerised infrastructure. Most individuals simply think of power failures in the context of lightening strikes or some other so called act of God; however these opinions are very far from the truth.

In actuality, most power failures are not from an angry deity, but from altogether more benign sources. The reality is that your computer suite is more vulnerable from the contractor down the road with his big yellow JCB, or from the site electrician who has forgotten which breaker does what, in the jumbled up, spaghetti wired power distribution panel. Or what about one of the most common causes of a PC computer crash, the cleaner pulling the plug to use the vacuum cleaner, yes, it really happens! Many have the genuinely misguided opinion that a UPS is there essentially to protect against a power failure, and its true that such a failure can be a disaster for any IT installation. But in reality the electrical threats are much wider and more subtle than most can imagine, here are some threats explained, and how the T6 Compact+ can protect your system.

> Brown Outs


A brown out happens when the voltage to your network drops to a point whereby by it can cause a server or PC to simply stop working. The effect is the same as a full power failure, but may only last a second or two, or maybe even less. To illustrate, how often have you experienced your lights dim, just briefly? 90% of the time this is because of a voltage drop, or brown out. The T6 Compact+ is designed to deal with this subtle threat, offering your servers a fully regulated and clean supply regardless of the input voltage, and it will even record the event so that you can investigate at a later time.

2 | AEC | T6 COMPACT +

> Spikes
Spikes are very short bursts of high voltage and high energy; these are often caused by the stopping and starting of motors or compressors, typically air conditioning or chilling units. Smaller but equally disruptive spikes can be caused by laser printers or other similar machines. These spikes have a nasty habit of locking or freezing a computer program, an irritation we have all experienced. There is a bigger danger that larger spikes can easily damage a power supply, hence many quality servers have two. The T6 Compact+ incorporates high energy absorbing filters that will mitigate this threat, offering your network a clean and regulated supply.

> Installation Simplicity


A 15kVA T6 Compact+ weighs in at only 90Kg (no batteries), even its bigger brother the T6+ 40kVA weighs in at a meagre 141Kg. The weight advantage proves to be very useful when having to use lifts to site the UPS, as raised floors generally dont have to be reinforced and the whole siting procedure is made safer because of integrated wheels and easy manoeuvrability. Add to these features convenient cable access and battery installation, and its easy to see why we call the T6 Compact, the T6 Compact +.

Performance,
compactness and reliability for critical applications
T6 COMPACT + | AEC | 3

> Configurations
The T6 Compact+ offers ultimate protection for data networks, CCTV and other essential applications, thanks to its cutting edge modular design. Every T6 Compact+ is packed with communications options and optional operating modes. Normal mode is as a double conversion UPS, alternatively the T6 Compact+ can be configured to run as a line-Interactive system (green mode), further reducing energy costs or as a frequency converter, again all programmable. The T6 Compact+ is available from 10kVA to 30kVA in three to single phase and from 10kVA to 40kVA three to three phase. The technology of the T6 Compact+ series is true double conversion. With Double conversion technology, the load is run 100% of the time by a continuously rated inverter, with the output voltage and frequency being regulated, cleaned and constantly monitored. Added to the inverter section are additional output filters which remove any other electrical noise, even in bypass mode.

> Reduced Power Consumption


When running in its normal On-Line mode the T6 Compact+ can offer an AC/AC efficiency of 92%, this increases to 98% in DC to AC mode. Achieving a high DC to AC efficiency means that the batteries can run for longer, thus your network runs for longer. Should Green Mode be selected then AC to AC efficiency increases to approximately 98%, In Green Mode the T6 Compact+ acts as a Line-Interactive device, so that in the event that the mains fail, the load will be supported within less than 2 m/s by the battery. Note: when in On-Line mode there is no time delay between mains fail and battery on.

4 | AEC | T6 COMPACT +

> Serviceability
MTTR (Mean Time to Repair) can mean a lot more than just four letters when responsible for the efficient running of an IT network or production plant. A low MTTR is what all serious users need, in fact demand! This requirement is no problem for the T6 Compact+, which offers features that dramatically reduce service or repair times. Even before an engineer arrives on site, a problem can be diagnosed via the LCD screen or through a software interface. All circuit boards are housed within drawer like modules and are accessed via the front of the UPS, so removal and replacement of a drawer can be done in less than ten minutes.

> Battery Management


To off-set the unavoidable process of battery decay, the T6 Compact+ incorporates a battery management system which is calibrated in accordance with almost any battery manufacturers specifications. If at some future point you want to use an alternative brand of battery other than the original its no problem, after a small adjustment the T6 Compact+ will accommodate your desired brand. The T6 Compact+ is a transformerless UPS with an IGBT A great friend of current ripple and equally destructive is temperature, the hotter a battery gets the less it performs. Battery temperature within the T6 Compact+ is carefully monitored, with the data being passed back to the charger. input and output all controlled by DSP technology (Digital Signal Processor). Again here we have acronyms, IGBT, DSP, but how do these affect you, the user? The combination of Isolated Gate Bipolar Transistors and Digital Signal Possessing, allows the T6 Compact+ to have an almost negligible effect on the mains supply, in that less than five percent harmonic distortion is generated. The benefit of this important feature is that a generator can be down sized by as much as 50%, the user, will more than likely fall outside any financial penalty bands that many EEC countries are considering for mains pollution. Should the batteries get warmer the T6 Compact+ will adjust its charging regime to reduce voltage. Any life threatening battery problems will automatically be raised as an alarm, giving an opportunity to remedy the problem.

> Mains Friendly

T6 COMPACT + | AEC | 5

> Standard Properties


Hi Level diagnostics via LCD screen or lap top. Input power factor correction .99pf
Low audible noise.

> Blade Server Compatibility


The T6 Compact+ will work with almost any type of load accepting power factors of either .9 leading or .9 lagging (many other manufactures standard is .8pf). This makes it ideally suited for applications with Blade Servers, or other devices where a leading power factor can offer a serious challenge, a challenge not all UPS can meet.

Back feed protection Green Mode. Modular Construction High speed temperature compensated
battery charge

Light weight and compact. Front access Made in EEC

> Efficiency
DSP, IGBT, Tri Core technology, all add up to an efficient UPS, and efficiency equates to saving substantial amounts of money. Achieving >92% in On-Line mode, this is typically 7% to 8% better than a conventional UPS, in real terms you could be saving 2.8KW per hour on a 40kVA installation. Imagine a 2.5KW electric fire running in your office day in day out, this is the potential saving you could make with the help of the T6 Compact+! Because the T6 Compact+ runs efficiently, generating less

> Optional Accessories


Parallel capacity/ redundancy Isolation transformer External bypass External battery
cabinets

heat, the air conditioning system can be down rated on an almost pro-rata basis, again savings are made, another big PLUS for the T6 Compact+.

Battery switch box

Battery thermal probe Transformers/


autotransformers for voltage adaption

The T6 Compact+ runs so


efficiently, the air conditioning can be down rated

6 | AEC | T6 COMPACT +

T6COMPACT +
TECHNICAL SPECIFICATIONS
POWER - KVA Capacity (kVA/kW) Dimensions WxHxD (mm) Weight (kg) w/o battery with battery Input/output connection Battery INPUT Nominal voltage Voltage range Frequency Power factor Current distortion (THDi) OUTPUT Nominal voltage Frequency Voltage regulation PF acceptable without de-rating Overload capacity 220, 230, 240 Vac single phase 220/380, 230/400, 240/415 Vac three phase 50/60 Hz 1% static; 2% dynamic 100% load change, <10 ms recovery time Lagging to 0.9 leading 101125% for 10 min (on-line); 126150% for 1 min (on-line); 500% for 1 cycle (bypass) Efficiency EPS (Eco-mode) Options >92% >98% Parallel capacity/redundancy; isolation transformer; external bypass; external battery cabinets, battery switch box; battery thermal probe; transformers/ autotransformers for voltage adaptation; USER INTERFACE Front panel Standard communication ports Optional ENVIRONMENTAL Operating temperature Storage temperature Altitude Audible noise at 1 meter (dBA) STANDARDS & CERTIFICATION Marking Safety EMC Test and Performance Quality CE IEC EN 62040-1 IEC EN 62040-2 IEC EN 62040-3 ISO9001 :2000 0C +40C -10C +70C <1000 m <60 Graphical LCD display, mimic with LEDs and keyboard RS232 serial port, USB port, Emergency Power Off input, battery switch monitoring port Web/SNMP, ModBus, relay, modem cards; remote panel; monitoring, managing and shutdown software 220/380, 230/400, 240/415 Vac three phase -20%, +10% from nominal 50/60 Hz (4565 Hz) 0,99 3% 90 250 100 260 100 260 10 kVA 10/8 15 kVA 15/12 20 kVA 20/16 10 kVA 10/8 15 kVA 15/12 20 kVA 20/16 30 kVA 30/24 40 kVA 20/16

450x1200x650 90 250 100 260 100 260 141 141

Hardwired (dual input) Internal or external, 360 cells

Hardwired (optional dual input) External, 360 cells

The data and text contained within this brochure are for general information only and can not be deemed as definitive, specifications can change without notice. T6 COMPACT + | AEC | 7

AEC UK
Systems House Eckington Business Park Rotherside Road Eckington Sheffield. S21 4HL Tel: 0044 01246 431431

Fax: 0044 01246 431444 Email: sales@aeceuro.co.uk Web: www.aeceuro.co.uk