INTRODUCTION 1.1 CONFIGURATION 1:
2
3 3 3 4
PRE-REQUISITES CONFIGURATION 1
Figures
Figure 1 - Configuration 1 Physical Topology ................................................................................. 4 Figure 2 - Huanyang Front Control Panel ....................................................................................... 5
Revision History
Version Draft 1.0 Date 04/12/11 Author Michael Prinzi Reviewer / Approver Version Details Initial draft
Chapter
1
Huanyang Speed Control
Introduction
Previously I wrote a guide on how to control you machines speed via Pulse Width Modulation. In this guide I will detail how to control a 3 phase motor, that being a spindle or lathe motor with a 3 pole switch and the speed via a potentiometer.
1.1
Configuration 1:
1. VFD Huanyang HY02D223B 1.5Kw Spindle Drive Controller 2. 10K Linear Potentiometer (Jaycar RP3510) 3. 3 Pole toggle switch
Pre-Requisites
None
Light Reading
In addition, you need to familiarise yourself with the appropriate hardware manuals supplied by the component vendors. These are available from their respective webpage. 1. Huanyang VFD Manual
You should download and read the manual prior to embarking on the configuration set out within this guide. Be aware of the warnings within these manuals relating to Mains Power Interfaces. You have been warned again!!
Chapter
2 1
Configuration
Configuration 1
The following diagram shows the physical connectivity between the elements used in the solution. This solution comprises of the following specific hardware. 3 Phase motor Huanyang HY02D223B (1.5KW HF VFD) Use this diagram to wire up the units
Note: The values shaded grey have been included as a reference and are what I used to enable my 3 phase motor to work with the VFD.
PD Value PD 01 PD 02 PD 03 PD 04 PD 05 PD 06 PD 07 PD 08 PD 09 PD 10 PD 11 PD 70 PD 71 PD 72 PD 73 PD 74 PD 75 PD 76 Manual Control 1 1 11 50 60 2.5 0.5 220 63 6.5 0 0 20 0 50 0 0 0
To set the values in the VFD via the front panel (Figure 2), use the following sequence: 5
1. 2. 3. 4. 5. 6. 7. 8.
Press Prog Enter Programming Mode Press Up Button Sets a value of 1 Press Set Save Value Press Set Enter PD002 as the Software automatically increments numbers Press Up Button Sets a value of 1 Press Set Save Value Press Prog Exit Programming Mode etc
Chapter
3
Acronyms
Acronym ACM PROG PWM Vi VFD +10V Meaning Common Terminal of Analog & Control Signals Programming Mode Pulse Width Modulation Analog Voltage Frequency Reference Input Variable Frequency Drive Power Supply for Speed Setting