uried flexible structures used for culverts, drainage, and sewers are fabricated from a variety of materials to form soil-interaction pipe systems. The physical properties of each material or combination of materials used to fabricate pipe are characterized by either linear or non-linear elastic behavior that is strongly influenced by strain rate. This paper discusses the basic material properties that affect strength, the technical differences between the terms flexibility factor and pipe stiffness, the practical implementation of flexibility and stiffness values that are associated with various pipe products, and how these affect handling, installation, and shortterm and long-term performance.

Material properties of flexible pipe


When the AASHTO LRFD Bridge Design Specifications Section 12

were written, all buried structures were grouped together in a common document. This is convenient for the designer who is charged with evaluating and specifying buried pipe and conduit that is used for culverts, drainage, and sewers. This article focuses on flexible pipe structures. Considering engineering mechanics of solids, there are two general classes of material used to fabricate flexible pipe. Materials that are classified as linear elastic include steel (AASHTO M36, M245) and aluminum (AASHTO M196) pipe of various corrugation depths and steelreinforced thermoplastic pipe (AASHTO MP20-10). Materials that are classified as non-linear include corrugated, solidwall and profile-wall high-density polyethylene or HDPE (AASHTO M294, and ASTM F714-08, respectively), profilewall and solid-wall polyvinyl chloride or PVC (AASHTO M304 and AASHTO

Ninety-six-inch steel-reinforced polyethylene pipe installation in New Mexico M278) and glass-reinforced polymer mortar (ASTM D3262 and D3754). Table 1 lists these flexible pipe types and compares properties.

Instructions
The Professional Development Series is a unique opportunity to earn continuing education credit by reading specially focused, sponsored articles in CE News. If you read the following article, display your understanding of the stated learning objectives, and follow the simple instructions, you can fulfill a portion of your continuing education requirements at no cost to you. This article also is available online at www.cenews.com/continuingeducation.html. After reviewing the learning objectives below, read the Professional Development Series article, complete the quiz, and mail or fax your answers to the Professional Development Series sponsor for grading. Submittal instructions are provided on the Reporting Form on page 6. If you answer at least 80 percent of the questions correctly, you will receive a certificate of completion from the Professional Development Series sponsor within 90 days and will be awarded 1.0 professional development hour (equivalent to 0.1 continuing education unit in most states). Or, go to www.cenews.com/continuing-education.html to take the quiz online; quiz answers will be graded automatically and, if you answer at least 80 percent of the questions correctly, you can immediately download a certificate of completion. Note: It is the responsibility of the licensee to determine if this method of continuing education meets his or her governing board(s) of registrations requirements.

Learning Objectives

After reading this article, you should be able to: Understand the intrinsic behavior of buried flexible pipe structures Distinguish between design strength and serviceability parameters as defined by national specifications Understand the nuances between laboratory-based quality control procedures and experience-based installation quality assurance best practices Understand the practical considerations of the concepts pipe stiffness and flexibility factor

Professional Development Series Sponsor


CONTECH Construction Products Inc.

2 PDH

Professional Development Advertising Section CONTECH Construction Products Inc.

glass fibers show linear elastic behavior in a small displacement field (small strain), they do, along with most polymers used to fabricate plastic pipe, behave with visco-elastic characteristics and exhibit creep under long-term loads. The industry recognizes the difference between short-term and longterm plastic pipe properties and sets elastic modulus properties accordingly. Depending on the chemistry of the thermoplastic material, the ratio of short-term to long-term elastic modulus ranges between 3 and 5.

Design for strength


All flexible pipes are designed for strength using the same general approach. For a given material, wall section, and pipe diameter: the applied loads are determined, soil-interaction with the flexible pipe is modeled, stress in the wall area is computed, then local effects such as buckling or seam strength are checked. Linear elastic materials are addressed in AASHTO LRFD Section 12.7 and non-linear plastic materials are

Strain gage placement per steel-reinforced polyethylene pipe full-scale load testing As a linear elastic material, metals behave predictably within typical service temperatures and maintain their mechanical properties under constant load (Figures 1 and 2). Thermoplastic materials exhibit non-linear elastic behavior and are sensitive to rate of strain, temperature, and creep. Creep is a visco-elastic phenomenon where the strain in a material continues to increase with time when subjected to a constant load (Figure 3). Although

Table 1 Comparison of round flexible pipe systems


Primary Structural Material Corrugated Steel inch & inch deep Corrugated Steel-1 inch deep Spiral Ribbed Steel Steel Structural Plate Steel-Reinforced Polyethylene Corrugated Aluminum inch & inch deep Corrugated Aluminum-1 inch deep Spiral Ribbed Aluminum Aluminum Structural Plate Glass-Reinforced Polymer Mortar* Profile Wall PVC Solid Wall PVC Solid Wall HDPE Corrugated HDPE Elastic Behavior Linear Linear Linear Linear Linear Linear Linear Linear Linear Non-Linear Non-Linear Non-Linear Non-Linear Non-Linear Creep Behavior No No No No No No No No No Yes Yes Yes Yes Yes TemperatureShort-Term Elastic Long-Term Elastic Dependent Behavior Modulus (ksi) Modulus (ksi) No No No No No No No No No Yes Yes Yes Yes Yes 29,000 29,000 29,000 29,000 29,000 10,000 10,000 10,000 10,000 2,600 440 440 110 110 29,000 29,000 29,000 29,000 29,000 10,000 10,000 10,000 10,000 1,500 140-158.4 140-158.4 22 22

* GRPM pipe elastic modulus are apparent values based on hoop testing.

Professional Development Advertising Section CONTECH Construction Products Inc.

PDH 3

The Practical Differences in Material Properties of Flexible Pipe Products


addressed in AASHTO LRFD Section 12.12. Readers will notice that while the two specification sections use the same general approach to overall design, the physical differences in the character of the materials are treated with appropriate elastic or thermoplastic consideration. The engineer must use judgment to select appropriate short or long term modulus values. These values are necessary for limit state computations. Inconsistencies between descriptive language and the equations within the AASHTO specification can be difficult for the engineer to interpret.

Pipe stiffness as a quality control procedure


ASTM D2412 is known as the parallel plate test and is used to measure the load at which a predetermined deflection is observed in a particular sample of plastic pipe. The parallel plate test is governed by ASTM sub-committee 17.11, which has responsibility for developing and maintaining standards for plastic pipe. In the test method, the term pipe stiffness is used to quantify laboratory behavior that is somewhat unique to thermoplastic pipe and reinforced polymer mortar pipe. The test method recognizes possible variability in measured data because of the intrinsic properties of thermoplastic pipe materials. As a result, the rate of deflection and testing temperatures are specified in exact terms. One purpose of carefully controlled test conditions is to establish a precision statement for the test method. Precision statements are mandatory for all ASTM Test Methods per the ASTM manual on Form and Style for ASTM Standards (March 2010). The Form and Style manual states: Precision is the closeness of agreement between test results obtained under prescribed conditions. A statement on precision allows potential users of the test method to assess in general terms its usefulness in proposed applications. A statement on precision is not intended to contain values that can be duplicated in every users laboratory. Instead, the statement provides guidelines as to the kind of variability that can be expected between test results when the test method is used in one or more reasonably competent laboratories. The results from the practical application of the test method help a manufacturer with quality control for a product as various day-to-day production variables must be addressed. Certificates ensuring the purchaser that a quality control program is utilized should accompany the materials during delivery. As part of an overall quality control plan, a manufacturer can use the test method to: establish a baseline for product

Serviceability
Serviceability is considered for all flexible pipe materials. The overall idea is that a flexible, round pipe should stay (essentially) round during fabrication, handling, delivery, installation, backfilling operations, and initial soil consolidation. All of the soil-interaction models are based on the assurance that a round pipe maintains the desired shape. Also, all joint types, including soil-tight, silt-tight, leak-resistant, and special designs (designed to resist shear, bending, pull apart, pressure, or water-tight), are dependent on the anticipated roundness of the pipe (AASHTO PP63-09). Because construction is not a perfect science, some allowances are made recognizing that flexible round shapes wont be perfect in geometry, but will still function as desired while being structurally sound. The approach to checking the handling and installation stiffness (or how well the pipe is expected to maintain a round shape) for most flexible pipe systems is based on the concept of the flexibility factor or FF which is computed by the equation: FF = D 2/EI (inches/kip)
(Equation 1)

Figure 1: Constant load applied to a material

Figure 2: Constant strain response under constant load

Figure 3: Increasing strain response under constant load. Example shows slight recovery after load is removed.

where D = Diameter in inches (in.); E = Est = Short Term Modulus (ksi); and I = Moment of Inertia of the Pipe Wall (in.4/in.) The computed flexibility factor should not exceed the limits prescribed by AASHTO Section 12. Note that the short-term modulus for plastic pipe does not account for any temperature effects during stockpiling or storage immediately prior to installation.

4 PDH

Professional Development Advertising Section CONTECH Construction Products Inc.

acceptance compare various plastics in pipe form study the interrelations of dimensions and deflection properties of plastic pipe and conduit measure the deflection and loadresistance at any of several significant events (liner cracking or crazing, rupture, wall cracking, or wall delamination) if they occur during the test (visible to the unaided eye)

terms are different than the numbers that result from tested pipe stiffness. For example, strain is computed for thermoplastic pipe per AASHTO Section 12.12.3.5.4 using a series of equations that consider pipe stiffness. Throughout the computations, the long-term modulus value is used. In this procedure, the equation for pipe stiffness is: PS = F/ = EltI/(0.149 R3) (kip/in.-in.)
(Equation 3)

ASTM D2412 defines pipe stiffness (PS) as: PS = F/y (lbf/in./in.)


(Equation 2)

where F = Force per inch of Pipe Length (lbf/in.) y = Deflection at F (in.) The test method warns, although PS units are dimensionally the same as those for pressure and stress, they are different quantities and should not be confused one with the other. As a result, pipe stiffness as determined by ASTM D2412 is not the same as the pipe stiffness value used in AASHTO Section 12.12. Simply stated, this is not a direct comparison. The prescribed deflection rate and temperature of the ASTM parallel plate test are not relevant to actual in situ loads and exposure temperatures of a buried pipe. For a composite pipe system such as steel-reinforced polyethylene, the use of pipe stiffness per ASTM D2412 is intended to provide a basis for manufacturing quality control not structural design. AASHTO MP20-10 states, The pipe shall have minimum pipe stiffness at 5 percent deflection as listed [in the tables] 5 percent deflection criteria was selected for testing convenience and should not be considered as a limitation with respect to in-use deflection.

where F = Load per inch of Pipe (kip/in.) = Vertical Deflection of Pipe (in.) Elt = Long Term Modulus (ksi) I = Moment of Inertia of the Pipe Wall (in.4/in.) R = Radius of Pipe to Centroid of Wall Section (in.) Unlike Equation 3, it is important to emphasize that in the procedure described by ASTM D2412, the magnitude of pipe stiffness is determined by a carefully controlled laboratory test. Traditionally, pipe stiffness is not used for corrugated metal pipe; however, it does have usefulness with steel-reinforced polyethylene pipe. Although dimensionally the same as stress, pipe stiffness does not compute a magnitude of stress in the pipe wall.

At the jobsite, installation assurance should follow industry standards such as AASHTO LRFD Bridge Construction Specifications. Corrugated metal pipe is addressed in Section 26 and thermoplastic pipe is addressed in Section 30. Both specification sections state that the overall performance of the flexible pipe is highly dependent on installation handling, backfill material, and methods used to place and compact the backfill. Final visual inspection and acceptance of the installation by the owners technical representative is made significantly easier when appropriate consideration is given to pipe flexibility and pipe stiffness principles. At the time of this article, the principles of either Section 26 or 30 can be used for the installation of steel-reinforced polyethylene pipe.

Conclusion
Many flexible pipe systems are commercially available in a variety of materials, sizes, and wall configurations. In order to understand the overall behavior, design, and installation of flexible pipe, it is important to know how to navigate various industry specifications. Practitioners should be aware that the key difference between the behavior of metal and steel-reinforced polyethylene pipe and the behavior of thermoplastic pipe is how the time-dependent modulus is applied. Appropriate use of flexibility factor and pipe stiffness concepts for serviceability is emphasized. Pipe stiffness is not necessarily related to the buried pipes ability to handle loads. Pipe stiffness, as determined by ASTM D2412, is a tested value and it is not used in strength checks in the AASHTO specification. Appreciation of the differences related to types of pipe materials being considered for applications is critical. Misconceptions and misuse of standards should be avoided. With careful consideration and understanding of design principles, the practitioner can evaluate short-term installation considerations along with long-term structural reliability.

Pipe stiffness and flexibility factor for quality assurance


Where quality control is procedural and testing protocol establishes a basis for acceptance, quality assurance is practice based and related to documenting or providing a pledge of performance. In a manufacturing setting, quality assurance takes the form of providing a certificate or some other tangible means that the product was manufactured, tested, and supplied in accordance with a predetermined specification. The pipe stiffness values, as measured by the parallel plate test in ASTM D2412, provide data relevant to acceptance of a finished product compared with an established baseline in strictly controlled laboratory testing conditions.

Tested pipe stiffness versus structural design capacity


Equations in AASHTO Section 12.12 contain terms that appear to be similar to pipe stiffness. These computed

Professional Development Advertising Section CONTECH Construction Products Inc.

PDH 5

The Practical Differences in Material Properties of Flexible Pipe Products


Darrell Sanders, P.E., is chief engineer for CONTECH Construction Products Inc. He holds a B.S. degree in Civil Engineering from the University of Cincinnati and an MBA from the University of Dayton. He has been a registered Professional Engineer in Ohio since 1996. Sanders is a member of several industry committees, including NCSPA, AASTHO, ASTM, and Uni-Bell. Andrew Jenkins, E.I., is the national plastic products manager for CONTECH Construction Products Inc. He holds a B.S. degree in Engineering from Missouri University of Science and Technology (Rolla). Jenkins experience comes from 13 years in the petroleum, mining, and civil engineering industries.

REFERENCES
AASHTO LRFD Bridge Design Specifications, 5th Edition, 2010. AASHTO M36, Standard Specification for Corrugated Steel Pipe, MetallicCoated, for Sewers and Drains. AASHTO M245, Standard Specification for Corrugated Steel Pipe, Polymer-Precoated, for Sewers and Drains. AASHTO M196, Standard Specification for Corrugated Aluminum Pipe for Sewers and Drains. AASHTO MP20-10, Standard Specification for Steel-Reinforced Polyethylene (PE) Ribbed Pipe, 300- to 900-mm (12- to 36-in.) Diameter. AASHTO M294, Standard Specification for Corrugated Polyethylene Pipe, 300- to 1500-mm (12- to 60-in.) Diameter. ASTM F714-08 Standard Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter. AASHTO M304, Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Wall Drain Pipe and Fittings Based on Controlled Inside Diameter. AASHTO M278, Standard Specification for Class PS46 Poly (Vinyl Chloride) (PVC) Pipe. ASTM D3262, Standard Specification for Fiberglass (Glass-FiberReinforced Thermosetting-Resin) Sewer Pipe. ASTM D3754, Standard Specification for Fiberglass (Glass-FiberReinforced Thermosetting-Resin) Sewer and Industrial Pressure Pipe. AASHTO PP63-09, Standard Practice for Pipe Joint Selection for Highway Culvert and Storm Drains. ASTM D2412, Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading. ASTM Form and Style for ASTM Standards, March 2010. AASHTO LRFD Bridge Construction Specifications, 3rd Edition, 2010.

Professional Development Series Sponsor:


9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 Phone: 800-338-1122 Fax: 513-645-7993 Email: info@contech-cpi.com Web: www.contech-cpi.com

CE News Professional Development Series Reporting Form


Article Title: The Practical Differences in Material Properties of Flexible Pipe Products Publication Date: December 2010 Sponsors: CONTECH Construction Products Inc. Valid for credit until: December 2012

Instructions: Select one answer for each quiz question and clearly circle the appropriate letter. Provide all of the requested contact information. Fax this Reporting Form to 513-645-7993. (You do not need to send the Quiz; only this Reporting Form is necessary to be submitted.) Or, go to www.cenews.com/continuing-education.html to take the quiz online.
1) 2) 3) 4) 5) a a a a a b b b b b c c c c c d d d d d 6) 7) 8) 9) 10) a a a a a b b b b b c c c c c d d d d d

Required contact information


Last Name: Title: Address: City: Telephone: Fax: State: E-mail: Zip: First Name: Firm Name: Middle Initial:

Certification of ethical completion: I certify that I read the article, understood the learning objectives, and completed the quiz questions to the best of my ability. Additionally, the contact information provided above is true and accurate.
Signature: Date:

6 PDH

Professional Development Advertising Section CONTECH Construction Products Inc.

Quiz instructions
On the Professional Development Series Reporting Form, circle the correct answer for each of the following questions. Or, go to www.cenews.com/continuing-education.html to take the quiz online; quiz answers will be graded automatically and, if you answer at least 80 percent of the questions correctly, you can immediately download a certificate of completion.

1. Linear elastic behavior is associated with a) Corrugated metal and steel-reinforced thermoplastic pipe b) Flexible thermoplastic pipe c) Materials that are sensitive to temperature and strain rate d) All of the above 2. Non-linear behavior is associated with a) All flexible pipe systems containing some thermoplastic b) Flexible thermoplastic pipe c) Corrugated metal and steel-reinforced polyethylene pipe d) All of the above 3. Creep behavior in soil-interacting flexible pipe is a) Observed when a soil mass moves down hill b) Commonly observed with corrugated metal and steelreinforced polyethylene pipe c) Independent of time d) Observed when strain increases under constant load 4. If a short-term modulus of a flexible, thermoplastic pipe is reported to be 250 ksi, a reasonable estimate of the long-term modulus is a) Exactly 250 ksi b) About 60 ksi c) About 1,000 ksi d) About 440 psi 5. The dimension lb/in./in. per ASTM D2412, is physically and mechanically the same as stress or pressure (psi). a) True b) False

d) Both used in evaluating corrugated metal and steelreinforced thermoplastic pipe 7. Careful control of laboratory temperature and strain rate in the parallel plate test are needed to a) Establish a baseline for comparing materials b) Judge consistency in measured observations c) Establish quality control acceptance for day-to-day variability in manufacturing d) All of the above 8. When evaluating the thickness of a corrugated metal pipe section a) Lower flexibility factor is likely to assure good installation b) Higher flexibility factor is likely to assure good installation c) Computed flexibility factor must equal the AASHTO LRFD value d) Computed flexibility factor must be determined in a laboratory environment 9. A serviceability check using flexibility factor assures overall quality by providing a) A combined material compressive strength and wall section with adequate area for a given diameter b) A standard to be sure a round pipe maintains the desired shape c) Inspection guidelines for aggregate gradation d) All of the above 10. After a flexible pipe is installed, finished pavement is in place, and all contractors have de-mobilized a) Consideration of flexibility factor is no longer necessary b) Pipe stiffness is important to analyze long-term pipe strength to resist paving loads c) The owners technical representative should request quality control/quality assurance certificates d) Any deviation from theoretically perfect geometry should be questioned

6. Pipe stiffness and flexibility factors are a) Linearly proportional to each other b) Used to compute wall stress c) Both used in evaluating thermoplastic pipe

Professional Development Advertising Section CONTECH Construction Products Inc.

PDH 7

Providing the Perfect Sanitary Solutions


Steel Reinforced Bell and Spigot

A2000 PVC Pipe

Dur

A STEEL REINFORCED POLYETHYLENE PIPE

Steel Reinforced Pressure Rated Polyethylene Resin

INNOVATIVE AND PROVEN SOLUTIONS


A2000 PVC
Diameters 12 to 36 Fast Installation Innovative Joint Design 27 Years of History ASTM F949

DuroMaxx SRPE
Diameters 36 to 96 Lightweight Water Tight & ElectroFusion Joints Proven Materials (Reinforced Pressure Rated Resin) ASTM F2562

Since 1963, CONTECH Construction Products has been a leader in providing sanitary solutions. A-2000 and DuroMaxx combine innovative pipe design with proven materials.

Knowledge. Solutions. Service.

CONTECH Construction Products Inc. 800.338.1122 www.contech-cpi.com

S-ar putea să vă placă și