6
159 [6.25]
159 [6.25]
19 [1,150]
14
27
22
20
2.47
[4.0]
[8.0]
[6.5]
[6.0]
[8.1]
EXHAUST SYSTEM
Maximum Allowable Back Pressure ..kPa [in Hg]
Maximum Bending Moment at Turbine Outlet Mounting Flange Nm [ftlb]
Maximum Incremental Direct Load at Turbine Outlet Mounting Flange
kg [lb]
10 [3]
22 [16]
9 [20]
4 [15]
6 [25]
17 [30]
TBD= To Be Determined
http://marine.cummins.com
Cummins Inc.
Marine Engine General Data Sheet
LUBRICATION SYSTEM
Oil Consumption Rate (Volume Percent of Fuel Consumption Rate)
Oil Pressure at Normal Operating Temperature
Idle Speed - Minimum in Main Oil Gallery
Rated Speed - Measured in Main Oil Gallery (Low)
Rated Speed - Measured in Main Oil Gallery (High)
Max. Allowable Oil Temperature (Sump)
Oil Pan Capacity (Shallow) OP
Low ..
High .
Total System Capacity (Max. Sump + Filter(s))
Oil Pan Capacity (Deep) OP
Low
High ..
Total System Capacity (Max. Sump + Filter(s))
By-Pass Oil Filter Capacity
0.07
kPa [psi]
kPa [psi]
kPa [psi]
C [F]
138
345
483
121
liter [gal]
liter [gal]
liter [gal]
32.2 [8.5]
37.9 [10.0]
47.3 [12.5]
liter [gal]
liter [gal]
liter [gal]
liter [gal]
64.4
71.9
81.4
2.8
[17.0]
[19.0]
[21.5]
[0.75]
30.3
45.4
6.1
34.5
0.0
96
71
5%
[8.0]
[12.0]
[1.6]
[5.0]
[0.0]
[205.0]
[160.0]
COOLING SYSTEM
Coolant Capacity
Engine Only liter [gal]
Engine Including Heat Exchanger and Integral Expansion Tank liter [gal]
liter [gal]
Min. Coolant Makeup Capacity
kPa [psi]
Max. Pressure Drop Across Any External Cooling System Circuit
Max. Allowable Block Coolant System Pressure kPa [psi]
C [F]
Max. Coolant Temperature at Engine Outlet
Min. Block Coolant Temperature (Warm Engine) C [F]
Capacity
Min. Allowable Coolant Expansion
p
Space
p
.% of System
y
p
y
Sea Water Pump Specifications.. Refer to MAB 0.08.17-07/16/2001
ELECTRICAL AND STARTER SYSTEM
Electrical
Min. Recommended Battery Capacity
Cold Cranking Amperes Rating (CCA)
Marine Cranking Amperes Rating (MCA)
Reserve Capacity (Discharging 25 Amps @ 80F) minutes
Volts
Min. Allowable System Voltage (@ Battery While Running)
Volts
Min. Allowable System Voltage (@ Battery While Cranking)
Volts
Max. Allowable System Voltage (@ Battery While Running)
Volts
Max. Allowable Voltage Drop of Starting Circuit (While Cranking)
rpm
Min. Engine Cranking Speed
Air Starter
Regulated Pressure for Air Starter System kPa [psi]
TBD= To Be Determined
[20]
[50]
[70]
[250]
12V
24V
0
0
320
12.0
0
15.5
0.0
150
900
1125
320
21.0
18
31.0
2.6
150
1034
150
http://marine.cummins.com