OPERATING MANUAL DIGITAL DRIVER MODULE MODEL NUMBER:

21XXX-YDM
DOCUMENT NUMBER: 51A14095A

This Operating Manual is for use with AOM Drivers with model numbers: XXX = a fixed frequency of between 27 and 300 MHz crystal controlled. Y = 0.4, 1, or 2 Watts output D = Digital Modulation M = OEM Module

Document approved for release: W Seale

Date: 9/23/05

US OFFICE: NEOS Technologies, Inc. 4005 Opportunity Drive Melbourne, FL 32934 USA Tel: (321) 242-7818 Fax: (321) 242-1019 Email: neos@neostech.com UK OFFICE: Gooch & Housego The Old Magistrates Court Ilminster, Somerset TA19 0AB UK Tel: +44 1460 52271 Fax: +44 1460 54972 Email: sales@goochandhousego.com

NEOS Technologies, Inc

a Gooch and Housego Company

TABLE OF CONTENTS Section I. II. III. IV. V. VI. Description INSPECTION PROCEDURE DESCRIPTION SPECIFICATIONS OUTLINE DRAWING CONTROLS AND CONNECTIONS TESTING PROCEDURE OPERATING PROCEDURE Page 3 4 5 6 7 8 9

51A14095A.doc

2 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION I INSPECTION PROCEDURE

a Gooch and Housego Company

Examine the shipping carton for damage. If the shipping carton or packing material is damaged it should be kept for the carriers inspection. Check the contents of the shipment for completeness, mechanical damage, and then test the equipment electronically. Operating procedures are contained in Section V. Notify the carrier and NEOS Technologies. If the contents are incomplete, or the equipment does not pass the electrical testing please notify NEOS Technologies. If there is any problem with the use of this equipment, or if the equipment fails to function as expected contact NEOS Technologies, do not try to trouble shoot or repair this equipment. Consult with a NEOS service engineer. If the equipment needs repair or replacement, contact NEOS Technologies, Inc for a Return Authorization Number.

51A14095A.doc

3 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION II. DESCRIPTION

a Gooch and Housego Company

The model 21XXX-YDM is a crystal controlled RF frequency generator designed to supply a signal of XXX MHz., where XXX is a fixed frequency of between 27 and 300 MHz. at up to two Watts maximum output; and is used to drive the NEOS Technologies 15000, 23000, 24000, 26000 free space series and fiber coupled series acousto optic modulators. The standard output power setting Y is typically 0.4, 1 or 2 Watts. The output signal can be modulated by a Digital TTL external signal, applied to Digital Modulation input. The output power is adjustable through the hole in the cover. If purchased with a NEOS AO Modulator, the RF power will be preset for optimum performance. The unit is supplied as a OEM module and requires the customer to supply 24 Volts to power the unit and the unit must be attached to an adequate heatsink.

21XXX-YDM 53B2384 DIGITAL DRIVER MODULE

51A14095A.doc

4 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION III SPECIFICATIONS


PARAMETER:
Output Frequency: Stability: Spurious Levels: Harmonic Distortion: Digital Input:

a Gooch and Housego Company

SPECIFICATION:
XXX MHz Where XXX = a fixed frequency of between 27 and 300 MHz + 0.01% Quartz Stabilized -50 dBc Maximum -15 dBc Maximum TTL Levels TTL HIGH = Full RF Power TTL LOW = Minimum RF Power 0 Volt = Minimum RF Power Rise Time PRF: 10 to 90 % < 30 ns typical < 18 ns typical < 8 ns typical Fall Time PRF: 90 to 10 % < 30 ns < 18 ns < 8 ns Extinction Ratio Minimum < -50dB < -40dB < -30dB

Output Frequency 27 to 50 MHz 50 to 150 MHz 150 to 300 MHz RF Output Power:

0.4, 1, or 2 Watts, Nominal Adjustable, Factory Set for Optimum Performance When Paired with a NEOS AO Device. 50 Ohms Nominal + 24 VDC + 0.5 Volt 1 Amp Maximum

Output Impedance: Supply Voltage: Supply Current:

MAXIMUM RATINGS:
Supply Voltage: Power Output: Case Temperature: + 28 Volts No DC Feedback Allowed + 550 C The Driver Must Be Attached to an Adequate Heatsink.

CONNECTORS & MECHANICAL:


RF Output Connector: Modulation Input Connector: Power Supply Connections: Physical Size: Vcc Return BNC Female BNC Female Solder Post Ground Lug 4.8" L x 1.61" H x 3.87" W

RELATED DOCUMENTS:
Outline Drawing: 53B2384

51A14095A.doc

5 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION IV OUTLINE DRAWING

a Gooch and Housego Company

51A14095A.doc

6 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION V

a Gooch and Housego Company

CONTROLS AND CONNECTIONS

A. RF Out

BNC - Female

RF Power Output The output is a factory set, crystal controlled, fixed frequency of between 27 and 300 MHz with an output power set nominally to 0.4, 1, or 2 Watts. When purchased with a NEOS AOM the output power will be set to give optimum performance. It must be terminated with a 50 Ohm load capable of dissipating 2 Watts or an AOM of the same power capability. B. Modulation Input BNC - Female The modulation input accepts TTL level signal. A TTL HIGH = Full RF Power and a TTL LOW = Minimum RF Power. All above signals are referenced to the shield of the BNC connector. C. Level Adjust The level adjust is a factory adjustment, but is accessible through the hole in the cover. Note: Do not adjust the output power above the value specified as maximum for the AOM as this will result in damage to the AOM. D. Power in Solder Post, and Ground Lug +24 volts DC @ 1 Amp.

TOP VIEW

51A14095A.doc

7 of 9

ECO # 58A18365

NEOS Technologies, Inc SECTION V OPERATING PROCEDURES TESTING PROCEDURE:

a Gooch and Housego Company

With the power off, attach a 50 Ohm load capable of dissipating 2 Watts to the "RF Output" of the unit. Apply +24 Volts to the 24V INPUT solder post of the module and return to the Ground Lug. Apply a TTL HI to the Modulation Input port through a 50 Ohm cable. Measure the frequency and output power and other parameters of the driver. ( Note: power is factory pre-set to match the NEOS AO device for optimum performance and is listed on the AO device Acceptance Test Results form. Other parameters are listed on the Acceptance Test Results form included with this driver.) Adjust, if necessary, the output power to the power level necessary for the AO device to be driven for optimum performance. The adjustment is accessible through the hole in the cover. Warning: The RF power should never exceed that specified for the AO Modulator driven. See the AO device manual for power limitations and other warnings. If damage results due to overpowering the AOM, the warranty will be void. Apply a TTL modulating signal to the Modulation Input. Measure the RF output for specifications for this driver as listed in the Acceptance Test Results form included with this driver. The driver has been designed and has been tested to meet the specification. Notify NEOS Technologies, Inc if the driver does not pass the electrical testing.

51A14095A.doc

8 of 9

ECO # 58A18365

NEOS Technologies, Inc OPERATION PROCEDURE:

a Gooch and Housego Company

The driver should be pre-set to output RF power at the required power level for the AOM. With the power off, attach the NEOS 15000, 23000, 24000, or 26000 free space or fiber coupled acousto optic modulator or other acousto optic modulator device to the driver with a 50 Ohm cable. Apply +24 Volts to the 24V INPUT solder post of the module and return to the Ground Lug. Apply a TTL HI to the Modulation Input port through a 50 Ohm cable. Follow the instructions in the AO Modulator manual to align and adjust the optical modulator, as required for optimum performance. Apply a TTL signal to the Modulation Input as desired.