Fivalco
General Information
Fivalco is a US company in our 20th year of manufacturing Fire Protection Valves of uncompromising quality for our discerning customers. All our products are FM or UL approved and most carry both UL and FM listings / approvals. The latest edition of the NFPA code stated products shall be listed or approved, without reference to either UL or FM although it is common practice for consultants to specify both a UL listing and a Factory Mutual approval. UL listed means that the product has been tested, has passed all the stringent tests mandated by UL and is listed in the UL catalogue of Fire Protection Equipment FM approved means that the product has passed all severe tests mandated by Factory Mutual and is approved by FM for use in building structures insured by Factory Mutual Insurance. We, and all other manufacturers of similar products are subject to identical factory and product audit approvals and tests without compromise as the same approval and test criteria are applied to all producers of such products. All buttery and gate valves are pressure tested for approval at 4 times the working pressure depending on valve size, and all valves must pass a cycling test of 1000 open/shut operations without failure of any part or component. We take great care to make our products both attractive and functional and it is essential that our customers and end users do the same in order to maintain product integrity and proper function. We draw your attention to minimum practices for handling and installation of our valves,at the end of this catalogue. We are not content with making valves purely to meet mandatory specications and have added quality and other features to stand out above the crowd. All gate valves have Stainless Steel Stems for better corrosion resistance-our competitors use common brass. All gate valves are painted true Fire Engine Red-RAL 3000-no on site painting needed. All materials for Buttery Valves are equal to or superior to our competitors
Fivalco
Product Index Approved and Listed Valves
CHECK VALVES
FIRE CHECK DCG GROOVED END ................................................................................................................................6/7
BREECHING INLET
TWO WAY BREECHING INLET ........................................................................................................................................29 FOUR WAY BREECHING INLET .......................................................................................................................................30
LANDING VALVES
LANDING VALVES 2-1/2'' BS FLANGED .........................................................................................................................31 LANDING VALVES 2-1/2'' BS THREADED .......................................................................................................................32
Fivalco
Highriser Gate Valve
Resilient Seated-300PSI-OS&Y Type-Flanged End
Valve Standard: Conforms to AWWA C515 / BS5163 Working pressure: 21 BARS/300PSI. Fusion Bonded Epoxy Coated Interior and Exterior RAL3002 Flanged Ends: ANSI B16.1 Class125/150/250, EN1092-2 PN10/PN16,BS10 Table E Stainless Steel Stem
Fig No.: 3299-300-F
Materials List:
Name Body Wedge Wedge Nut Stem Bonnet Gasket Packing Stem Nut Handwheel Material Ductile Iron ASTM A536 65-45-12 Ductile Iron ASTM A536 65-45-12 +EPDM Stainless Steel AISI 304 Stainless Steel AISI304/302 Ductile Iron ASTM A536 65-45-12 EPDM Graphite Bronze ASTM B62 Ductile Iron ASTM A536 65-45-12
Dimensions (In/mm):
Size Size L H D 2-2/1/65 7.50/191 16.46/418 7.20/183 3/80 8.00/203 19.21/488 9.96/253 4/100 9.00/229 21.18/538 9.96/253 5/125 10.0/254 25.75/654 12.05/306 6/150 10.50/267 29.13/740 12.05/306 8/200 11.50/292 36.81/935 13.98/355 10/250 13.00/330 44.33/1126 17.52/445 12/300 14.00/356 51.81/1316 17.52/445
Notes:
1. Design and dimensions conform to AWWA C515. 2. Flanged to ANSI B16.1, 125#. other flange types available. 3. Fusion bonded epoxy coated interior and exterior. 4. Valve is rated at 300PSI for Fire Protection Service. 5. Design and materials are subject to change without notice.
Fivalco
Highriser Gate Valve
Resilient Seated-300PSI-NRS Type-Flanged End
Valve Standard:Conforms to AWWA C515 / BS5163 Working pressure: 21 BARS/300PSI. Fusion Bonded Epoxy Coated Interior and Exterior RAL3002 Flanged Ends: ANSI B16.1 Class125/150/250, EN1092-2 PN10/PN16/BS10 Table E Stainless Steel Stem
Materials List:
Name Body Wedge Disc Disc Nut Stem Gasket Bonnet Thrust Collar Gland Wrench Nut Post Plate Material Ductile Iron ASTM A536 65-45-12 Ductile Iron ASTM A536 65-45-12 +EPDM Bronze ASTM B62 Stainless Steel AISI 304/302 EPDM Ductile Iron ASTM A536 65-45-12 Bronze ASTM B62 Ductile Iron ASTM A536 65-45-12 Ductile Iron ASTM A536 65-45-12 Ductile Iron ASTM A536 65-45-12
Dimensions (In/mm):
Size L H D 2-1/2/65 7.50/191 11.61/295 12.01/305 3/80 8.00/203 12.72/323 12.01/305 4/100 9.00/229 13.46/342 12.01/305 5/125 10.00/254 16.06/408 12.01/305 6/150 10.50/267 17.32/440 12.01/305 8/200 11.50/292 21.14/537 12.01/305 10/250 13.00/330 25.20/640 12.01/305 12/300 14.00/356 28.46/723 12.01/305
Notes:
1. Stainless steel stem. 2. Design and dimensions conform to AWWA C515. 3. Flanged to ANSI B16.1, 125#. other flange types available. 4. Fusion bonded epoxy coated interior and exterior. 5. Valve is rated at 300PSI for Fire Protection Service. 6. Design and materials are subject to change without notice. 7. All valves Provided with 2"(50mm) operating Nut.
Fivalco
Fireriser Indicator Post
Long Post
Fig. No: IP888
Materials List:
No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Qty 1 1 2 2 1 1 4 4 2 2 4 4 1 6 6 1 4 4 1 1 1 1 1 1 1 Name Locking Wrench Operating Nut Hex Nut Screw Hex Nut Snap Ring Target Carrier Nut Target Hex Cap Nut Window Glass Window Glass Gasket Hex Cap Screw Hex Nut Body Hex Cap Screw Hex Nut Base Flange Hex Cap Screw Hex Nut Crane Coupling Cotter Pin Stand Pipe Stem Plug Cover Locking Nose Material ASTM A126B ASTM B62 ASTM A105 ASTM A105 AISI 066 ASTM B62 ASTM B108 ASTM A105 LEXAN-UN PTFE ASTM A105 ASTM A105 ASTM A536 ASTM A105 ASTM A105 ASTM A126B ASTM A105 ASTM A105 ASTM A536 AISI 304 ASTM A53 AISI A1045 AISI 304 ASTM A126B ASTM 307 B
Field Adjustment:
1. Remove the top section from the top of the Indicator Post assembly. 2. Cut the required length off the bottom of the Standpipe for the Ground Line to match up with Standpipe Ground Line mark. 3. Set the "OPEN" and "SHUT" targets for the appropriate valve size. 4. Reattach the Top Section to the top of the Indicator Post assembly. 5. Design and dimensions are subject to change without notice.
Fivalco
Fireriser Indicator Post
Wall Type
Fig. No: WP999
Materials List:
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Component Lifting Eyey Bolt Hex Nut Washer Hand Wheel Operating Nut Hex Cap Screw Hex Nut Snap Ring Target Carrier Nut Target Hex Cap Screw Window Glass Window Glass Gasket Hex Cap Screw Hex Nut Body Stand Pipe Stem Cotter Pin Crane Coupling Plug Cover Locking Nose Qty 1 1 1 1 1 2 2 1 1 4 4 2 2 4 4 1 1 1 1 1 1 1 1 Material ASTM A105 ASTM A105 ASTM A105 ASTM A536 ASTM B62 ASTM A105 ASTM A105 AISI 066 ASTM B62 ASTM B108 ASTM A105 LEXAN-UN PTFE ASTM A105 ASTM A105 ASTM A536 ASTM A53 AISI 1045 AISI 304 ASTM A536 AISI 304 ASTM A126B ASTM 307 B
Field Adjustment:
1. Remove the top section from the top of the Indicator Post assembly. 2. Set the "OPEN" and "SHUT" targets for the appropriate valve size. 3. Reattach the Top Section to the top of the Indicator Post assembly. 4. Design and dimensions are subject to change without notice.
Fivalco
Fireriser
Indicator Post Adjustment
Installation
NOTE: Ensure that the Non-rising Stem Gate Valve is in the fully open position before installing the Ver-tical Indicator Post. If the Non-Rising Stem Gate Valve is opened left: move the two Open Targets(16)to the very top of the Target Carrier Assembly(12+13+14). Locate the two Shut Targets(not shown) according to the Non-rising Stem Gate Valve size(stem) turning distance. If the Non-rising Stem Gate Valve is opened right: move the two Shut Targets(not shown) to the very top of the Target Carrier Assembly(12+13+14). Locate the two Open Targets(16) according to the Non-ris-ing Stem Gate Valve size(stem) turning distance.
Maintenance
Oil the bearing in the Top Section(20) at least once per year by adding several drops of oil in the hole located on the top of the Operating Nut(19).
Fivalco
Highriser Grooved Check Valve
Fig.No.:DCG
SPECIFICATIONS Working Pressure : 300 PSI (21 Bars) Max. Test Pressure: 500 PSI (34.5 Bars) Max. Working Temp : 250 ( 120 )
Material
Ductile iron conforming toASTMA-536 epoxy coated Red or black (optional) 2"-5" type 304 or 302 stainless Steel to ASTMA-167 6"-8" ductile iron conforming to ASTMA-536, grade 65-45-12 Grade E EPDM -40 to 230 ( -40 to 110) Service Temperature range Type 304 stainless steel to ASTMA-123 ASTMA-213 ASTMA-312 or ASTMA-269 Type 302 stainless steel to ASTMA-313 Type 304 or 302 stainless steel to ASTMA-580 Sintered bronze to ASTMB-438
Clapper
Clapper Facing
Fivalco
Highriser Grooved Check Valve
Grooved Check Valves,UL.ULC Listed/FM Approved Grooved End, Size: 2-1/2", 3", 4", 6" and 8"
WORKING PRESSURE 300PSI/21BARS
The Check Valve is a compact, cost effective valve offering low pressure-drop, non-slam performance the Check valve assembly is lighter and fast to install, and costs less than anged and wafer valve assemblies. In the fully-open position the clapper is held tightly against the valve body, out of the flow stream, to provide maximum ow area and prevention of clapper utter. The clapper design produces quick, non-slam closure before ow reversal can occur, while meeting FM requirements for an anti-water hammer valve rating. Each valve is hydrostatically tested for leak tightness to 500 PSI. The clapper-seat design permits leak free sealing of back pressures in service conditions ranging from 300 PSI to as low as 5 P I
Fig.No:DCG
Fivalco
Fireriser Buttery Valve
Wafer Type Buttery Balves, UL, ULC Listed/FM Approved Wafer Type, Sizes: 2-1/2", 3", 4", 6" and 8".
SPECIFICATIONS
Working Pressure: 300 PSI (21Bars) Max.Test Pressure: 600 PSI (42.8 Bars) Max.Working Temp: 250 (120) Factory installed UL, listed double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No:HPW
Material
ASTM A-536 Nylon-11 Coated ASTM B-536 EPDM Encapsulated AISI 420-SS AISI 410-SS ASTM A-536 ASTM A-536 ASTM A-536 ASTM A-510 ASTM B-148 or B-548 EPDM Grade"E" EPDM Grade"E"
Fivalco
Fireriser Buttery Valve
Grooved Buttery Valves, ULULC Listed/FM Approved
Specifications
Working Pressure: 300 PSI (21Bars) Max.Test Pressure: 600 PSI (42.8 Bars) Max.Working Temp: 250 (120) Factory installed UL, listed double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:HPG
Material
ASTM A-536 Nylon-11 Coated ASTM B-536 EPDM Encapsulated AISI 420-SS AISI 410-SS ASTM A-536 ASTM A-536 ASTM A-536 ASTM A-510 EPDM Grade"E" ASTM B-148 or B-584 EPDM GradeE EPDM GradeE
Fivalco
Fireriser Buttery Valve
Grooved Butterfly Valves, ULULC Listed/FM Approved Two Tapped Outlets
Specifications
Working Pressure: 300 PSI (21 Bars) Max.Test Pressure: 600 PSI (42.8 Bars) Max.Working Temp: 250 (120) Factory installed UL listed double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:HPGT
Material
ASTM A-536 Nylon-11 Coated ASTM B-536 EPDM Encapsulated AISI 420-SS AISI 410-SS ASTM A-536 ASTM A-536 ASTM A-536 ASTM A-510 ASTM B-148 EPDM Grade"E" EPDM Grade"E"
A
105 112 145 179 204
B
127 127 127 143.5 152.4
C
135 135 135 193 193
D
73.0 88.9 114.3 168.3 219.1
E
135 142 175 209 234
F
128 128 128 220 220
H
30 30 30
N
13 13 13 15 15
M
4--1/2-14NPT 4--1/2-14NPT 4--1/2-14NPT 4--3/4-14NPT 4--3/4-14NPT
6.8 24.2
40.4 40.4
Fivalco
Fireriser Buttery Valve
Water Type Buttery Valves,UL,ULC Listed/FM Approved DW Water Type,Size: 2-1/2", 3", 4", 6", 8"
Universal wafer Type Buttery Valve Suitable for Connecting to ANSI B 16 Class 125, ISO 2084/Din 2501 PN 16 & BS 4504 PN 16 Flanges Specifications
Working Pressure: 175 PSI (12.5 Bars) Max.Test Pressure: 350 PSI (25.0 Bars) Max.Working Temp: 250 (120) Factory installed UL, listed double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:DW
Material
ASTM A-536 EMPE Encapsulated ASTM B-548 or B-148 AISI 420-SS AISI 410-SS ASTM A-536 ASTM A-536 ASTM A-536 ASTM A-510 ASTM B-148 EPDM GradeE EPDM GradeE
Fivalco
Fireriser Grooved Buttery Valve
UL, ULC Listed/ FM Approved
Specifications
Working Pressure: 175 PSI(12.5 Bars) Max. Test Pressure: 350 PSI(25.0 Bars) Max. Working Temp.: 250 (120) Factory Installed UL Listed Double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:DG
Material
ASTM A-536 Nylon-11 Coated ASTM B-536 EPDM Encapsulated AISI 420-SS AISI 410-SS ASTM A-536 ASTM A-536 ASTM A-536 ASTM A-510 ASTM B-148 EPDM GradeE EPDM GradeE
Fivalco
Fireriser Buttery Valve
Bronze Buttery Valve, UL, ULC Listed/FM Approved BG Grooved End, Size: 2" and 2-1/2"
Specifications
Working Pressure: 175 PSI (12.5 Bars) Max.Test Pressure: 350 PSI (25.0 Bars) Max.Working Temp. : 250 (120) Factory Installed UL Listed Double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:BG
Material
ASTM B-505 ASTM B-548 EPDM Encapsulated ASTM A-564 Type XM12 ASTM A-564 Type XM12 ASTM A-619 ASTM A-619 ASTM B-16 ASTM A-283 ASTM B-16 ASTM A-307 EPDM Grade"E" NBR9
Fivalco
Fireriser Buttery Valve
Bronze Buttery Valves,UL,ULC Listed/FM Approved BT Size: 1", 1-1/4", 1-1/2", 2" and 2-1/2"
Specifications
Working Pressure: 175 PSI (12.5 Bars) Max. Test Pressure: 350 PSI (25.0 Bars) Max. Working Temp.: 250 (120) Factory Installed UL Listed Double Tamper Switches Valve Approved For Indoor and Outdoor Use
Fig.No.:BT
Material
ASTM B-506 ASTM B-548 EPDM Encapsulated ASTM A-564 Type XM12 ASTM A-564 Type XM12 ASTM A-619 ASTM A-619 ASTM B-16 ASTM A-283 ASTM B-16 ASTM A-307 EPDM Grade"E" NBR
Dimensions:
Size 1/25 1-1/4"/32 1-1/2/40 2/50 2-1/2/65 A 1.75(43.7) 2.16(54) 2.4(60) 2.8(70) 3.6(90) B 1.56(39.7) 196(47) 2.24(70) 2.8(70) 3.36(84) C 2.16(54) 2.68(67) 2.92(73) 3.3(82.4) 4.16(104) D 2.08(52) 2.24(56) 2.36(90) 2.56(54) 2.78(69.5) E 1.48(52) 1.64(41) 2.45(61.3) 1.96(49) 2.18(54.5) F 43 47 50 . . G 34.) 47 48.6 . .
Fivalco
Wafer Buttery Valve
PN20/300PSI
Valve Standards: Complies with EN593/BS5155/MSS SP-67 Conrms to LPCB Standard Requirement. Working Pressure and Temperature Working Pressure PN20/300PSI. Temperature from -10 to 100 for EPDM seat. Temperature from -10 to 82 for NBR seat. Top: Flange: Complies with ISO5211/1. End-To-End Dimensions according to MSS SP-67-2002 Flange Types: ANSI B16.1 Class 125/250,EN1092-2 PN10/PN16/BS10 Table E Operator: Gear operator. With two internal CE approved switches.
Fig.No.:2903
Material
Ductile Iron Tainless Steel DI EPDM Coated DI NBR Coated PTFE EPDM/NBR
EN Spec.
EN-JS1050 BS970 420S37 EN-JS1050 EN-JS1050 Commercial Commercial
ASTM Spec.
A536 65-45-12 AISI 416 A536 65-45-12 A536 65-45-12 Commercial Commercial
Dimensions:
Size A B C L1 L2 L3 2"/50 278 80 43 165 54 158 2-1/2"/65 292 89 46 165 54 158 3"/80 298 95 46 165 54 158 4"/100 317 114 52 165 54 158 5"/125 330 127 56 165 54 158 6"/150 343 145 56 165 54 158 8"/200 377 175 60 165 54 158 10"/250 472 223 68 172 75 230 12"/300 518 245 78 193 78.5 238
Fivalco
Grooved Buttery Valve
PN20/300PSI
Valve Standards: Complies with EN593/BS5155/MSS SP-67 Conrms to LPCB Standard Requirement. Working Pressure and Temperature Working Pressure PN20/300PSI. Temperature from -10 to 100 for EPDM seat. Temperature from -10 to 82 for NBR seat. Top: Flange: Complies with ISO5211/1. End-To-End Dimensions according to MSS SP-67-2002 Flange Types: Grooved dimensions comply with Metric or ANSI Pipe Standards Operator: Gear operator. With two internal CE approved switches.
Fig.No.:2902
Material
Ductile Iron Stainless Steel DI EPDM Coated DI NBR Coated PTFE EPDM/NBR
EN Spec.
EN-JS1050 BS970 420S37 EN-JS1050 EN-JS1050 Commercial Commercial
ASTM Spec.
A536 65-45-12 AISI 416 A536 65-45-12 A536 65-45-12 Commercial Commercial
Dimensions:
Size A B C a Pipe OD E F G H K 2"/50 100 70 82.4 16 60.3 136 158 54 165 65 2-1/2"/65 106 75 96.8 16 73.0/76.1 142 158 54 165 65 3"/80 112.5 82 96l8 16 88.9 148.5 158 54 165 65 4"/100 135 100 115.85 16 114.3 171 158 54 165 65 5"/125 148.7 119 147.6 16 139.7/141.3 184.7 158 54 165 65 6"/150 176 130 147.6 16 165.1/168.3 212 158 54 165 65 8"/200 204 162 133.4 19 219.1 240 158 54 165 65 10"/250 228.1 200 158.8 19 273.0 265.6 230 75 172 75 12"/300 266.2 224 163.6 19 323.9 304.7 238 62 193 77
Fivalco
Fireriser Installation Guide
Fivalco
Design Requirements
The Fivalco grooved butterfly valve should be connected to the piping system with aproved couplings or flange adapters. Flow may be from either direction, and the valve may be positioned in any direction. Fivalco butterfly valves have been designed with a slow close hand wheel operator which effectively minimizes water hammer. These valves feature minimum ow restriction and pressure loss when in the fully open position. When the valves are received from the manufacture they should be handled carefully to avoid breakage and damage to the seating area. Before installation of the valve, clean piping, ange and couping. When the valve closes hard, it is usually due to debris lodged in the sealing area. Often this may be corrected by backing off the hand wheel and closing again.
Installation
The valve should never be forced to seat by applying a wrench to the hand wheel as this may distort the valve componects or score the sealing surface. The use of excessive force to open or close the valve violates all warranties whether express or implied. The inlet and outlet pipe adjacent to the valve should be properly supported to prevent excessive stress on the valve body. The valve should not be used to force a pipeline into position as this may result in distortion of the valve body. Conduit and elecrical connections to the optional tamper switch must be in accordance with National Electrical Code(NFPA 72)and/or requirements of the local authority having jurisdiction.
Fivalco buttery valves require no regular maintenance, however, it is advisable to inspect and verify proper operation of the unit annually or in accordance with the authorty having jurisdiction. The inspection should include a visual check for leakage at the valve pipe connection and body to operator connection. Inspection and maintenance should be performed by a qualied inspection service.
Switch Installaion
Fivalco butterfly valves are provided with internal supervisory position switches. The tamper switch operates by a cam connected to the vallve stem. The switch will change positon and close within two(2) full turns of the hand wheel from the fully open position. Switch#1: For connection to the supervisory circuit. Normally closed Normally open Common : 2 Yellow : 2 Red : 2 White Switch#2: Auxiliary switch connected per authority. Normally closed Normally open Common Ground Lead :1 Yellow :1 Red : 2 White : 1 Green
Fivalco
Fireriser Installation, Operation and Maintenance of ResilientSeated Gate Valves
1. GENERAL
Resilient-seated gate valves form a significant component of many fire-fighting and water-distribution systems. Failure of a resilient-seated gate valve in such systems, either due to faulty installation or improper maintenance, could result in extensive damage and costly repairs. In addition, many resilient-seated gate valves are installed in buried-service or underground applications. Problems with or malfunctions of the valves due to faulty installation or improper maintenance may result in extensive and costly unearthing operation to effectively correct or eliminate the problem. Many resilient-seated gate-valve problems and failures can be traced back to improper installation, operation, or maintenance procedures.
2. UNLOADING
All valves should be unloaded carefully. Each valve should be carefully lowered from the truck to the ground; it should not be dropped. In the case of larger valves, forklifts or slings around the body of the valve or under the skids should be used for unloading. Only hoists and slings with adequate load capacity to handle the weight of the valve or valves should be used. Hoists should not be hooked into or chains fastened around yokes, gearing, motors, cylinders, or handwheels. Failure to carefully follow these recommendations is likely to result in damage to the valve.
4. STORAGE
Valves should be stored in the fully closed position to prevent the entry of foreign material that could cause damage to the seating surface. Whenever practical, valves should be stored indoors. If outside storage is required, means should be provided to protect the operating mechanism from weather elements. During outside storage, valves should be protected from the weather, sunlight, ozone, and foreign materials. In colder climates where valves may be subject to freezing temperatures, it is absolutely essential to remove the water from the valve interior and close the valve before storage. Failure to do so may result in a cracked valve casting and or deterioration of the resilient seat material.
5. INSTALLATION
At the jobsite prior to installation, each valve should be visually inspected and any foreign material in the interior portion of the valve should be removed. A detail inspection of the valve as outlined in Sec. 3 should be performed prior to installation. 5.1 Bolts all bolts should be checked for proper tightness and protected by the installer to prevent corrosion, either with a suitable paint or by polyethylene wrapping. 5.2 Underground Installation Valves in water-distribution lines shall, where practical, be located in easily accessible areas. 5.2.1 During installation there is the possibility of foreign materials inadvertently entering the valve. Foreign material can damage internal working parts during operation of the gate valve. For this reason, gate valves should be installed in the closed position. Each valve should be placed on rm footing in the trench to prevent settling and excessive strain on the connection to the pipe. Pipe systems should be supported and aligned to avoid damage to the valve. 5.2.2 A valve box or vault should be provided for each valve used in a buried-service application. The valve box should be installed so as not to transmit shock loads or stress to the valve. The valve box should be centered over the operating nut of the valve with the box cover ush with the surface of the nished area or such other level as directed by the owner. Valve boxes should be of such design that a trafc load on the top of is not transmitted to the valve. 5.2.3 Valves buried in unusually deep trenches should have special provisions for operating the valve either a riser on the stem to permit use of a normal key or a notation on the valve records that a long key will be required.
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006 -18-
Fivalco
5.2.4 When valves with exposed gearing or operating mechanisms are installed belowground, a vault designed to allow pipe clearance and prevent settling on the pipe should be provided. The operating nut should be accessible from the top opening of the vault with a valve key. The size of the vault should provide for easy remove of the valve bonnet and internal parts of the valve for purpose of repair. Consideration should be given to the possible entry of groundwater and /or surface water and to the need to provide for the disposal of such water. 5.3 Aboveground Installation Valve installed aboveground or in a plant piping system should be supported and aligned to avoid damage to the valves. Valve should not be used to correct the misalignment of piping. 5.4 Inspection After installation and before pressurization of the valve, all pressure-containing bolting (bonnet, seal plate, packing gland, and end connections) should be inspected for adequate tightness to prevent leakage. In addition, an inspection should be made for adequate tightness of all tapped and plugged connections to the valve interior. Proper inspection at this time will minimize the possibility of leaks after pressurization of the piping system. 5.5 Testing In order to prevent time lost searching for leaks, it is recommended that the Valve excavations are not backlled until after pressure tests have been made. After installation, it is desirable to test newly installed piping sections, including valves, at some pressure above the system design pressure. The test pressure should not exceed the rated working pressure of the valve. After the test, steps should be taken to relieve any tapped pressure in the body of the valve. The resilient-seated gate valve should not be operated in either the opening or closing direction at different pressures above the rated working pressure. It is also recognized that wear or foreign material may damage valve seating surfaces and may cause leakage. 5.6 Records On completion of the installation, valve location, size, make, type, date of installation, number of turns to open, direction of opening, and other information deemed pertinent should be entered on permanent records. 5.7 Application Hazards. Resilient-seated gate valves should not be installed in applications or for service other than those recommended by the manufacturer. 5.7.1 Resilient-seated gate valves should not be installed in lines where service pressure will exceed the rated working pressure of the valve. 5.7.2 Resilient-seated gate valves should not be used for throttling service unless the design is specically recommended for that purpose of approved in advance by the manufacture. 5.7.3 Resilient-seated gate valves should not be used in applications that are exposed to freezing temperature unless sufcient ow is maintained through the valve or other protection is provided to prevent freezing. 5.7.4 Gate valves should not be installed at a dead end or near a bend in a pipeline without proper and adequate restraint to support the valve and prevent it form blowing off the end of the line. 5.7.5 To prevent damage, 4 and below size NPS resilient-seated gate valves should not be operated with input torques greater than 200 ft-lb (270N.m). Gate valves 6 to 12 NPS should not be operated with input torques greater than 300ft-lb (406N.m).
Fivalco
7. Repairs
Leakage, broken parts, hard operation, and other major defects should be corrected by a repair crew as soon as possible after the defect has been reported. If repairs are to be performed in the eld, the repair crews should take a full complement of spare parts to the jobsite. Provisions should be made to isolate the defective valve from water pressure and relieve internal trapped pressure prior to performing any corrective maintenance. Disassembly of the valve should be accomplished in accordance with the procedure supplied by the manufacturer. After repairing the valve, the operating mechanism should be cycled through one complete operating cycle. With full line pressure applied to the valve in the open position, an inspection should be made to detect leakage in the areas around the seal plate, bonnet, packing gland, and body-end connections. A record should be made to indicate that the valve has been repaired and is in working condition. Any markings indicating that the valve is inoperable should be removed. In addition, fire departments and other appropriate municipal departments should be informed of the satisfactory repair of the valve.
Fivalco
Fireriser Buttery Valve
Buttery Valves Packing Firey BT & BG
UL Listed FM Approved Nom.Pipe End Size Connection In.
1" 1-1/4" 1-1/2" 2" 2-1/2" 2" 2-1/2"
mm
(25) (32) (40) (50) (65) (50) (65) TH TH TH TH TH GR(M) GR(M)
Suitable for ANSI B16.1 125,DIN 2633 ft DN2501 PN16 Water British Standard 4504 /PN 16 Flanges 2-1/2 3 4 6 8 (65) (80) (100) (150) (200) w w w w w 50 50 40 30 24 20.2/9.2 20.5/9.3 22.0/10.0 32.0/14.5 41.0/19.0 1050/475 1050/525 1000/400 960/435 1032/468
Note :GR-Grooved End. GRV-Grooved Metric End. Crate Dimensions: 2-1/2 to 4 Crate Dimensions: 6 and 8 Crate Dimensions: 10 and 12
TH--Threaded End W-Wafer Type. THM Threaded Metric End. (1.10m LX1.10m W X0.61mm H) (1.10m LX1.10m W X0.76mm H) TBA
Copyright Fivalco 2006 -21-
Fivalco
QuickonnectTM Flexible Sprinkler Connector
Anchoring components are intended for use with drop ceilings conforming to ASTM C635 and other major standards when installed in accordance with the Standard Practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels, ASTM C636 or other equivalent standards
Component List: NO
1 2 3 4 5 6 7 8 9
Part Name
Flexible Tube Nut Isolation Ring O-Ring Reducer Nipple Center Bracket End Bracket Square Bar
Material
SS304 S10C Nylon66 Silicon Zinc Plated Steel Zinc Plated Steel Zinc Plated Steel Zinc Plated Steel Zinc Plated Steel
Qty.
1 2 1 1 1 1 1 2 1
Technical Date
Rated Pressure:175PSI Maximum Ambient Temperature : 225(), 170 () Maximum Sprinkler K-factor for 1/2 in. outlet: 5.6gal/mm/(psi)1/2 Maximum Sprinkler K-factor for 3/4 in. outlet: 8.0gal/mm/(psi)1/2 Designed for use in Wet and Dry Systems Minimum Bend Radius: 8In/200mm
Model
FX(B)-07 FX(B)-08 FX(B)-10 FX(B)-12 FX(B)-15 FX(B)-18 FX(B)-07 FX(B)-08 FX(B)-10 FX(B)-12 FX(B)-15 FX(B)-18
in/mm
1/2(15mm) 1/2(15mm) 1/2(15mm) 1/2(15mm) 1/2(15mm) 1/2(15mm) 3/4(20mm) 3/4(20mm) 3/4(20mm) 3/4(20mm) 3/4(20mm) 3/4(20mm)
Fivalco
QuickonnectTM Flexible Sprinkler Connector
Installation Instructions
FXB: BRAIDED TYPE FX: UNBRAIDED TYPE NOTES: NPT + METRIC THREADS AVAILABLE: SPECIFY WHEN ORDERING -Packing : 20 pieces per carton per each size -
Place the two End brackets properly in position. Push the end brackets into the ceiling structure rails and check the end brackets sit securely on the rails. Fasten the wing bolts on the side of the End brackets nger tight. Do not over tighten
Insert the reducer from the side of the center bracket in a horizontal direction (not from the top vertically). Adjust the angle of the reducer by turning it gently into the bracket. Do not over tighten
Fivalco
Forged Brass Fire Hose Valve
FM Approved
Working Pressure And Temperature:
300PSI/21Bars with water Available as standard with threaded connections NPT/BSPT Other Thread types/end connections available for specic markets
Figure No.:FH-1
Material
Forged Brass Forged Brass Forged Brass Cast Iron High Tensile Brass PTFE High Tensile Brass FPM
ASTM Specification
ASTM B16 ASTM B16 ASTM B16 ASTM A48 Class 35 ASTM B16 Commercial ASTM B16 Commercial
FM Approved
Available with Male or Female Threaded Outlet as standard. Approval tested at 4 Times working pressure = 1200 PSI/83 Bars; Production tested at twice working pressure 600PSI/41 Bars
Dimensions (in/mm):
SIZE L H(Open) H(Closed) 1-1/2"/40 2.17/55 7.70/195.5 6.61/168 2-1/2"/65 3.15/80 10.69/272 8.9/226
Optional Finishes:
Forged Finish / Polished/ Forged Chrome Plated /Forged Polished Chrome Plated
Fivalco
UL Listed Trim Valves
Brass Ball Valve
Valve Standards:
Conforms to MSS SP 110
Material
B16 C36000 Brass PTFE B16 C36000 Brass B16 C36000 Brass PTFE Commercial FPM Commercial PTFE Commercial B16 C36000 Brass B16 C36000 Brass Steel Steel/PVC
Dimensions (mm)
SIZE L1 H L 1/2"/15 59 50 16 3/4"/20 67 58 17 1"/25 77 63 19 1-1/4"/30 90 78 21 1-1/2"/40 100 89 22 2"/50 100 96 24
Notes:
Approved under the SAFT brand - A Fivalco company.
Fivalco
UL Listed Trim Valves
Brass Globe Valve
Valve Standards:
BS/EN 13789/MSS SP85
Material
Copper alloy ASTM B16 C36000 Brass Brass PTFE Commercial Copper alloy ASTM B16 Copper alloy ASTM B16 Copper alloy ASTM B16 PTFE Copper alloy ASTM B16 Brass Cast Iron Aluminium Brass
Dimensions (mm):
SIZE L L1 H L2 1/2"/15 50 10.5 64 53.5 3/4"/20 55 10.5 69 53.5 1"/25 64 12.5 82 57.5 1-1/4"/30 73 14 94.5 71.5 1-1/2"/40 84 15 107 71.5 2"/50 90 16 120 77.5
Notes:
Approved under the SAFT brand - A Fivalco company.
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006 -26-
Fivalco
UL Listed Trim Valves
Angle Globe Valve
Valve Standards:
BS/EN 13789/MSS SP85
Material
Copper alloy ASTM B16 Brass ASTM B16 Brass ASTM B16 PTFE Commercial Copper alloy ASTM B16 Copper alloy ASTM B16 Copper alloy ASTM B16 PTFE Commercial Copper alloy ASTM B16 Cast Iron Aluminium Brass
Dimensions (mm):
SIZE L L1 H L2 1/2"/15 50 10.5 64 53.5 3/4"/20 55 10.5 69 53.5 1"/25 64 12.5 82 57.5 1-1/4"/30 73 14 94.5 71.5 1-1/2"/40 84 15 107 71.5 2"/50 90 16 120 77.5
Notes:
Approved under the SAFT brand - A Fivalco company.
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006 -27-
Fivalco
Automatic Air Vent Valve
PN 16/Class 125/ 235 PSI
Working Pressure and Temperature Working pressure PN16/Class 125./235 Psi Temperture from -10 to 120.
Fig. 9701
Material
Cast Iron Cast Iron Stainless Steel Stainless Steel Stainless Steel Carbon Steel Stainless Steel Viton Stainless Steel Stainless Steel Brass Stainless Steel
EN Spec.
EN-JL1040 EN-JL1040 BS970 304S15 BS970 304S15 BS970 304S15 Carbon Steel BS970 304S15 Commercial BS970 304S15 BS970 304S15 CuZn39Pb3 BS970 304S15
ASTM Spec.
A126 Class B A126 Class B AISI 304 AISI 304 AISI 304 A307 B AISI 304 Commercial AISI 304 AISI 304 B16 C36000 AISI 304
Dimensions (mm):
SIZE 1/2" 3/4" 1" 1/2"/15 1/2BSP or NPT 3/4BSP or NPT 1BSP or NPT
Fivalco
Two Way Breeching Inlet
Figure No.:BRE-2
Breeching inlets are provided to give Fire Brigade access to riser systems in the event of a re. Our products are manufactured and tested in accordance with BS 336/5043. Constructed of high quality materials from Fivalcoa leader in the Fire Protection Industry.
Materials List: No
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Component
Body 1" Couplling 1" Gate valve Plug Chain Chain Coupling M10 Nut Spring Stem O Ring Gasket Valve Seat Chain Gasket
Material
Cast iron ASTM A126 Class B Steel Commercial Brass B16 Plastic Steel Commercial Steel Commercial Brass B16 Brass B16 Steel Commercial Steel Commercial NBR Commercial NBR Commercial EPDM Commercial Steel Commercial EPDM Commercial
Dimensions:
Flange Size 4/100 A 222 B 180 C 100
Notes:
1.Hydraulic test 2.5MPA. 2.Painting red RAL 3000. 3.All dimensions in mm. 4.Flanges are PN16
Fivalco
Four Way Breeching Inlet
Figure No.:BRE-4
Breeching inlets are provided to give Fire Brigade access to riser systems in the event of a re. Our products are manufactured and tested in accordance with BS 336/5043. Constructed of high quality materials from Fivalcoa leader in the Fire Protection Industry.
Materials List: No
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Component
Body 1"Couplling 1"Gate valve Plug Chain Chain Coupling M10 Nut Spring Stem O Ring Gasket Valve Seat Chain Gasket
Material
Cast iron ASTM A126 Class B Steel Commercial Brass B16 Plastic Steel Commercial Steel Commercial Brass B16 Brass B16 Steel Commercial Steel Commercial NBR Commercial NBR Commercial EPDM Commercial Steel Commercial EPDM Commercial
Dimensions:
Flange Size 6"/150 A 285 B 240 C 150 L 265
Notes:
1.Hydraulic test 2.5MPA. 2.Painting red RAL 3000. 3.All dimensions in mm. 4.Flanges are PN16.
Fivalco
Landing Valves
Landing valves 2-1/2BS Flanged
Materials List: Component
Handwheel Chain Stem Plug O-Ring Body Seal O-Ring Valve Body Bolts Spring Nut Cap Coupler Seal
Figure No.:LVF
Material
DI ASTM ASS6-65-45-12 Commercial Steel Brass B16 Brass B16 EPDM EPDM EPDM Brass B16 Commercial Steel Tempered Steel Commercial Steel Brass B16 Coupler
Dimensions (mm)
Size 2-1/2/65 D 13 H 188 L 164.5
Fivalco
Landing Valves
Landing valves 2-1/2 BS Threaded
Materials List: Component
Handwheel Chain Stem Plug O-Ring Body Seal O-Ring Valve Body Bolts Spring Nut Cap Coupler Seal
Figure No.:LVS
Material
DI ASTM ASS6-65-45-12 Commercial Steel Brass B16 Brass B16 EPDM EPDM EPDM Brass B16 Commercial Steel Tempered Steel Commercial Steel Brass B16 Coupler
Dimensions (in/mm)
Size 2-1/2/65 H 207
Fivalco
Fivalco Inc. Limited Warranty
Fivalco Inc, warrants each metal valve to be free from defects in material and workmanship under normal use and service for a period of one year from the date of purchase. In the event that any defect is discovered which may be covered by this Warranty, the owner should contact Fivalco Inc, in writing or by telephone. The owner may be instructed to return the valve at owner's expense to Fivalco Inc, or an authorized Fivalco location for inspection. In the case that inspection reveals that the valve is defective it will be replaced at Fivalco Inc.'s expense. Replacements shall be shipped free of charge to the owners provided that the valve was installed in accordance with Fivalco Inc. Instructions and in accordance with the local authority having jurisdiction. To the extent permitted by law this warranty specifically excludes incidental and consequential damages of every type and description resulting from any claimed defect in material or workmanship, including, but not limited to, personal injuries and property damages. To the extent permitted by law, implied warranties of merchantability and tness for particular purposes are limited in duration. Some jurisdictions do not allow exclusion or limitation of incidental damages and such limitations may not apply to you. This warranty provides the owner with specic legal rights and owners may have other rights which vary by jurisdiction
Distributed By:
Fivalco
Distributor
Fivalco
Website: www.fivalcovalves.com