Sunteți pe pagina 1din 5

Remote Sensor System Switch Signal Transmission

DC2 wire Exclusive detector type


System configuration Characteristics -Possible to connect with Exclusive proximity switch RXD or mechanicla limit switch. -Possible to deliver with integrated exclusive proximity SW and cabel.

Switch Sitnal

RXD

Number of Signals 1 8

Two air gaps transmission type

- Remote Sensor System which inductively supply power and transmit signals through two air gaps. - Possible to connect with Exclusive proximity switchRXD.

Sensor type ( Detector ) -Exclusive proximity switch /RXD series

Signals

Operating distance 2mm

Size M12 M12 M18 M18 M30 M18

Type code Transmitter Output sensor

Page 48 48 49 50 51 52

RXT-1202-PU-_ _ RST-1202-PU-_ _ RXT-1805-PU-_ _ RXT8-1805-PU-_ _ RXT8-3010-PU-_ _


Transmitter Receiver

RXE-1202 -PU-_ _ RXE-1805 -PU-_ _ RXE8-1800 -PU-_ _ RXE8-3000 -PU-_ _


Emitter Output sensor

2mm 5mm 5mm 10mm 4mm

RXT-1805-PU-_ _ RWT-R1800-PU-_ _ RWT-E1800-PU-_ _ RPE-1804 -PU-_ _

Exclusive proximity switch/RXD series


RXD sensors are exclusive proximity switches for above-mentioned RXT-xxxx series
Series RXD seriesfor Exclusive detector type no LED
RXD

Operating distance 1.5mm 2mm 5mm 10mm

Size M8 M12 M18 M30

Type code

RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _

ApplicableTransmitter RXT-xxxx RXT8-xxxx

Page 55 55 55 55

Type code
: N NPNP PNPD DC2 wire(Transmitter only _ _ at the end means cable length(m). Examples are showed below.

RXT-1202-PU-01
cable length(m) 01=1m 02=2m 03=3m

Transmitter

RXE-1202N-PU-02
N=NPN P=PNP cable length(m) 02=2m 03=3m 05=5m

Output sensor

Standard cable length is 1m.

Standard cable length is 2m.

The Transmitter and the Output sensor should be same size on same table.

h16

Remote Sensor System Switch Signal Transmission


DC2 wire/ Exclusive switch type

Switch Signal

Number of Signals RXD

M 12
Transmitter Output sensor

Size

0...2mm

Operating distance

4 1 LED

M12x1 17 (20) (1000)

30 35.5

38 61.5 (2000)

A009

Wiring Transmitter
Type code Detector RXD

C012/P.109

Output sensor
Type code NPN

Mechanical SW Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface

RXT-1202-PU-01 RST-1202-PU-01
----1 0...2mm0...1.6mm 1.5mm --0...+50 IP67 PUR / 5 2x0.34mm2 Nickel plated brass Nylon12 : operating distance at flush-mounted

PNP Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface

RXE-1202N-PU-02 RXE-1202P-PU-02
24V DC 10incl. ripple 25mA 1 max.100mA 25Hz Signal output indication 0...+50 IP67 PUR / 5 3x0.34mm2 Nickel plated brass Nylon12

Note

Note

Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.

Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.

Influence of surrounding metal

Mutual interference

Typical Transmitting DiagramSupply voltage at 24V /non-flush mount


RXT-1202-PU-_ _ / RXE-1202 -PU-_ _
Y mm
Y

C
B

4 3
2
X

Center offset Operating distance (mm)

1
8 6 4 2 0 2 4 6 X 8

Type code RXT-1202-PU-_ _ RXE-1202 -PU-_ _


rated value

A(mm) 126

B(mm)

C(mm)

120 10020

: flush-mounted

h48

Power Output sensor Power supply/ PLC

RXD

Transmitter

Switch Signal

Number of Signals RXD

detected signal

DC2 wire/ Exclusive switch type M 18


Transmitter Output sensor
4 1 LED
Size

0...5mm

Operating distance

Remote Sensor
Products table
(2000)

M18x1 24 (29) A010 (1000) 40

10

10

33.5 59

DC3 wire Detector type DC3 wire Terminal type Wiring C012/P.109 DC2 wire Detector type DC2 wire Terminal type DC2 wire/ Exclusive switch Exclusive switch DC2 wire/ Two air gaps Exclusive proximity swithch Terminal Box Accessories Thermocouple K type Thermocouple J type Resistance thermometer sensor

Transmitter
Type code

Output sensor
Type code

Detector RXD RXT-1805-PU-01 ----1 0...5mm0...4mm 2.5mm --0...+50 IP67 PUR / 5 2x0.34mm2 Nickel plated brass Nylon12

NPN PNP

RXE-1805N-PU-02 RXE-1805P-PU-02
24V DC 10incl. ripple 25mA 1 max.100mA 25Hz Signal output indication 0...+50 IP67 PUR / 5 3x0.34mm2 Nickel plated brass Nylon12

Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface

Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface

Note

Note

Applicable switch
- This remote sensor is only for the followings.(refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.

Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.

Load Cell Analog sensor

Influence of surrounding metal

Mutual interference Wiring Wiring


C

Typical Transmitting DiagramSupply voltage at 24V /non-flush mount


RXT-1805-PU-_ _ / RXE-1805 -PU-_ _
Y 7 6 mm
Y

B
Center offset Operating distance (mm)

5
4 3 2 X 10 8 6 4 2 0 2 4 6 8 10 1

Type code RXT-1805-PU-_ _ RXE-1805 -PU-_ _


rated value

A(mm) 189

B(mm)

C(mm)

180 11035

: flush-mounted

h49

Remote Sensor System Switch Signal Transmission


DC2 wire/ Exclusive switch type

Switch Signal

Number of Signals RXD

M 18
Transmitter Output sensor

Size

1...5mm

Operating distance

4 1 LED

M18x1 24 (29) A014

35 (1000) 61

10

10

63 77.5 94 (2000)

Wiring Transmitter
Type code

C027/P.109

Output sensor
Type code NPN

RXD/mechanical

RXT8-1805-PU-01
----8 1...5mm 2.5mm --0...+50 IP67 PUR / 7.9 9x0.2mm2 Nickel plated brass Nylon12

PNP Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface

RXE8-1800N-PU-02 RXE8-1800P-PU-02
24V DC 10incl. ripple 150mA 8+1inzone max.50mA/ output type 100Hz INZONE 0...+50 IP67 PUR / 7.7 2x0.5mm2+9x0.2mm2 Nickel plated brass Nylon12

Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface

Note

Note

Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.

Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.

Influence of surrounding metal

Mutual interference

Typical Transmitting DiagramSupply voltage at 24V /non-flush mount


RXT8-1805-PU-_ _ / RXE8-1800 -PU-_ _
Y
mm

C
B

7 6 5 4 3 2 1 6 5 4 3 21 0 1 2 3 4 5 6 X
X

Center offset Operating distance (mm)

Type code RXT8-1805-PU-_ _ RXE8-1800 -PU-_ _


rated value

A(mm) 18

B(mm) 18

C(mm) 110

h50

Power Output sensor Power supply/ PLC

Transmitter RXD

Switch Signal

Number of Signals RXD

detected signal

DC2 wire/ Exclusive switch type M30


Transmitter Output sensor
Size

1...10mm

Operating distance

LED

(41.5)

Remote Sensor
Products table
M30x1.5 36 35 13.5 13.5 66 83.5 95 (2000)

(1000)

64

DC3 wire Detector type DC3 wire Terminal type C027/P.109 DC2 wire Detector type DC2 wire Terminal type DC2 wire/ Exclusive switch Exclusive switch DC2 wire/ Two air gaps Exclusive proximity swithch Terminal Box Accessories Thermocouple K type Thermocouple J type Resistance thermometer sensor

A004

Wiring Transmitter
Type code

Output sensor
Type code

RXD/mechanical

RXT8-3010-PU-01
----8 1...10mm 3mm --0...+50 IP67 PUR / 7.9 9x0.2mm2 Nickel plated brass Nylon12

NPN PNP

RXE8-3000N-PU-02 RXE8-3000P-PU-02
24V DC 10incl. ripple 150mA 8+1inzone max.50mA/ output type 100Hz INZONE 0...+50 IP67 PUR / 7.7 2x0.5mm2+9x0.2mm2 Nickel plated brass Nylon12

Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface

Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface

Note

Note

Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.

Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.

Load Cell Analog sensor

Influence of surrounding metal

Mutual interference Wiring Wiring


C

Typical Transmitting DiagramSupply voltage at 24V /non-flush mount


RXT8-3010-PU-_ _ / RXE8-3000 -PU-_ _
Y mm

B
Y

14 12 10 8 6 4 2
161412108 6 4 2 0 2 4 6 810121416 X

Center offset Operating distance (mm)

Type code RXT8-3010-PU-_ _ RXE8-3000 -PU-_ _


rated value

A(mm) 30

B(mm) 20

C(mm) 200

h51