Sunteți pe pagina 1din 5

Operation And Maintenance Features

Subscriber Line Testing


See TPS

Issue of template: 25.06.97

Line Work Station (LWS)


See TPS

Ring Back Service (RBS)


Meaning of RBS Tones RBS reached Start of testing Result good Result conditionally bad Reault bad Result external voltage too high see TOG-Spec. Highway/Channel

Note: The RBS tones "RBS active", "RBS start of test" or "RBS result good-tone" come from highway 1 / channel 0.

Metallic Test Access (MTA)


See TPS

Trunk Testing
Trunk Testing With ATE
a) Test classes which can be used for outgoing trunks to EWSD and non-EWSD switches: Test Class 1 2 3 4 5 9 11 12 13 14 EWSD Std [X] [X] [X] [X] [X] [X] [X] [X] [X] [X] Testing ... Start Signal Start signal and tone level (broadband) Start Signal and End signal Start Signal, tone level (broadband) and End Signal Tone level (broadband) Start Signal, End Signal, 2nd Start Signal, Tone, 2nd End Signal Meter pulse as Class 2 but with given tone level as Class 4 as Class 5

Waiting time: 45 secs. ,Tone Level: > 256 msec., > -20 dBm

b) Special EWSD to EWSD, addressing of ETEAE, test classes for incoming and outgoing trunks: Test Class 6 7 EWSD Std [X] [X] Testing ... 1st Start Signal, End Signal 2nd Start Signal, ATE noise level measurement for <=45dBm0 Meter pulse ATE noise level measurement for <=45dBm0 [X] Start Signal, Meter Pulse, Tone Level

(BPO)
8

Ericsson

c) Test classes which can be used for outgoing international trunks: Test Class 56 57 58 59 60..57 70..67 80..77 90..87 EWSD Std [X] [X] [X] [X] [X] [X] [X] [X] Testing ... Responder without evaluation Q137 & Q490 Responder with evaluation (transmission level 0 dBm0) Q136 Responder with evaluation (transmission level -10 dBm0) Q136 Responder R2 Q490 Diverse responder with Answer Diverse responder with Answer / CLEAR BACK Diverse responder with EOS / Answer Diverse responder with EOS / Answer / CLEAR

ETEAE Programs
a) Responder and test functions used for incoming trunks:

Test Class 1

EWSD Std [X]

Testing ... After 2 seconds the ETEAE sends: 1st Start Signal and 1400 Hz tone for 2.5 seconds End Signal for 2.5 seconds 2nd Start Signal without tone until Release Start Signal and 1400 Hz tone for 5 sec., End Signal until Release Dial Tone for 1 second, pause for 1 second 5 times ... Start Signal and Dial Tone for 3 sec. End Signal for 1 second, 5th End Signal with additional information "Forced Release

[X]

After 1 second the ETEAE sends:

[X]

The ETEAE sends:

[X]

After 1 second the ETEAE sends: Start Signal and 820 Hz tone (6 seconds), End Signal 2 seconds and cyclic repetition until Release

b) Special responder functions for trunk tests EWSD-EWSD, test class for incoming trunks: Test Class 6 EWSD Std [X] Testing ... After 1 second the ETEAE sends- Acknowledge tone 1400 Hz (Note: This is not evaluated at the opposite end) - 1st Start Signal for 1 second, then End Signal for 1 second - 2nd Start Signal until release: 7 [X] Speech channels in both directions are connected in the ETEAE for the ATE tone level test Tones received are amplified by 0.5 dB and echoed back.

After 1 second the ETEAE sends: - Acknowledge tone 1400 Hz (Note: This is not evaluated at the opposite end) and then 1 meter pulse: Speech channels in both directions are connected in the ETEAE for the ATE tone level test Received tones are amplified by 0.5 dB and echoed back.

[X]

After 1 second the ETEAE sends: - Acknowledge tone 1400 Hz - Start Signal - 1st meter pulse Speech channels in both directions are connected in the ETEAE for the ATE tone level test Received tones are amplified by 0.5 dB and echoed back.

FTAM
Used host Host operating system Verification necessary ......... ......... [ ]

TMN
Standard as offered by version.

Monitoring
Standard as offered by version and rerouting to intercept subscriber like in SAL V7.1W.

Other O&M Features


None.