Sunteți pe pagina 1din 86

PDS Express Project Creation

Quick Start Guide

Document Number DPDS3-PE-200016A DPDS3-PE-200016B DPDS3-PE-200016C

Version PDS 7.1 PDS 7.3 PDS 8.0 SE

Date April 2002 October 2004 November 2005

Pages 1-86 Cover/Notice Cover/Notice

Copyright
Copyright 1984-2005 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization.

Restricted Rights Legend


Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Contractor Rights in Technical Data clause at DFARS 252.2277013, subparagraph (b) of the Rights in Computer Software or Computer Software Documentation clause at DFARS 252.227-7014, subparagraphs (b)(1) and (2) of the License clause at DFARS 252.227-7015, or subparagraphs (c) (1) and (2) of Commercial Computer Software---Restricted Rights at 48 CFR 52.227-19, as applicable. Unpublished---rights reserved under the copyright laws of the United States. Intergraph Corporation Huntsville, Alabama 35894-0001

Warranties and Liabilities


All warranties given by Intergraph Corporation about equipment or software are set forth in your purchase contract, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in this publication is accurate as of its publication date. The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document. The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.

Trademarks
Intergraph, the Intergraph logo, SmartSketch, FrameWorks, SmartPlant, INtools, MARIAN, and PDS are registered trademarks of Intergraph Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. MicroStation is a registered trademark of Bentley Systems, Inc. ISOGEN is a registered trademark of Alias Limited. Other brands and product names are trademarks of their respective owners.

_ _______________
If You Need Assistance
Intergraph Online
Our web site brings you fast, convenient, up-to-the-minute information about Intergraphs products, services, and direction. Our web address is: http://www.intergraph.com.

If You Need Assistance

Support
For the lasest Support Services information, use a World Wide Web browser to connect to http://www.intergraph.com/ppo/services/support.asp. If you are outside of the United States, please call your local Intergraph office. The most upto-date list of international offices and distributors is available on the web at http://www.intergraph.com.

Intergraph Directory
The following numbers are only valid in the United States unless otherwise indicated. If you are outside the United States, please call your local Intergraph office.

Intergraph General Information


All countries 1-256-730-2000

Training Registration
1-800-766-7701 (U.S. Only) 1-256-730-5400 (Outside the U.S.)

Mailing Address
Intergraph Process, Power & Offshore 300 Intergraph Way Madison, Alabama 35758 U.S.A. You can also reach us by electronic mail at info@intergraph.com.

_ _______________
Documentation Contacts
We are constantly working on updates and improvements to the documents and other educational media. If you have any suggestions on where we can improve the documentation or where you think more information is needed, let us know. You can reach us by: Mail Intergraph Process, Power & Offshore Documentation Manager 300 Intergraph Way Madison, AL 35758

_ _______________
Table of Contents
If You Need Assistance ........................................................................................................ Intergraph Directory ............................................................................................................. Preface ................................................................................................................................................. Related Documents ............................................................................................................... Whats in This Document ..................................................................................................... General Conventions .................................................................................................................... Keyboard Conventions ......................................................................................................... Terminology ......................................................................................................................... 1. Getting Started ............................................................................................................................. Project Setup Overview ........................................................................................................ Before You Begin ................................................................................................................. Starting the Program .................................................................................................................... 2. Creating a Standard Project .......................................................................................................... How to Use the New User Option ........................................................................................ 3. Creating a Customized Project ..................................................................................................... How to Use the Advanced User Option ................................................................................ 4. Understanding the express.txt File ............................................................................................... Seed Data .............................................................................................................................. Default File Locations .......................................................................................................... RDB Libraries ....................................................................................................................... Drawing Cell Libraries ......................................................................................................... 2D Reference Data ................................................................................................................ Appendix A: Appendix B: Appendix C: The express.txt File .................................................................................................... Sample Data ................................................................................................................ Delivered SQL Scripts ................................................................................................

Table of Contents

3 3 7 7 7 9 10 11 13 13 14 14 17 18 27 27 51 52 54 55 58 58 59 77 79 81

Index ....................................................................................................................................................

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

_ _______________
Preface
Creating a new PDS project includes many distinct tasks that can be difficult to remember from one project to the next, particularly if you do not frequently create new projects. With the 6.0 release of PDS, Intergraph is providing a new utility, Express Project Creation, which automates most of the steps needed to create a project. This document describes how to use Express Project Creation to set up both standard and customized projects. This document provides only a general description of project setup. For example, adding 3D project data to an existing 2D project or adding structural data to a project after it was created cannot be accomplished using Express Project Creation. Procedures of this nature are described in the PDS Project Setup Technical Reference (Intergraph document number DEA5067) and the PDS Project Administrator (PD_Project) Reference Guide (Intergraph document number DEA5027).

Preface

Related Documents
For more information on related topics, see the following documents: Document Number _ _______________ DEA5018 DEA5027 DEA5028 DEA5050 DEA5065 DEA5067 Document Title _____________ PDS 2D RDB Administrator Users Guide Project Administrator (PD_Project) Reference Guide Reference Data Manager (PD_Data) Reference Guide Getting Started in PDS 2D PDS 2D RDB Administrator Reference Guide PDS Project Setup Technical Reference

Whats in This Document


This document contains the following chapters: Chapter 1 Getting Started. This chapter provides an overview of the workflow for setting up a project and describes how the Express Project Creation program fits into this workflow. Chapter 2 Creating a Standard Project. This chapter describes how to use the New User option to create a project that uses a standard directory structure. Chapter 3 Creating a Customized Project. This chapter describes how to use the Advanced User option to create a customized project.

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 Chapter 4 Understanding the express.txt File. This chapter describes how to edit the express.txt file to further streamline your project creation workflow. Appendix A The express.txt File. This appendix lists the complete express.txt file that is delivered with the product. Appendix B Sample Data. This appendix describes the sample data that is available with the New User option. Appendix C Delivered SQL Scripts. This appendix describes the SQL scripts that are delivered with the PD_Shell product.

_ _______________
General Conventions
This document contains many visual cues to help you understand the meaning of certain words or phrases. The use of different fonts for different types of information allows you to scan the document for key concepts or commands. Symbols help abbreviate and identify commonly used words, phrases, or groups of related information.

Preface

Typefaces
Italic Indicates a system response, which is an explanation of what the software is doing. For example, The text is placed in the viewing plane. Bold Indicates a command name, parameter name, or dialog box title. Command paths are shown using an arrow between command names. For example, Choose File > Open to load a new file. Sans serif Indicates a system prompt or message, which requires an action be taken by the user. For example, Select first segment of alignment Bold Typewriter Indicates what you should literally type in. For example, Key in original.dat to load the ASCII file. Normal Typewriter Indicates an actual file or directory name. For example, The ASCII report is stored in the layout.rpt file.

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

Symbols
This document uses the following symbols to represent mouse buttons and to identify special information: <C> <D> <R> <T> Command button Data button (usually the left mouse button) Reset/reject button (usually the right mouse button) Tentative button (usually the center mouse button) Note Important supplemental information.

Warning Critical information that could cause the loss of data if not followed.

Technical tip or information provides information on what the software is doing or how it processes information. Map or path shows you how to get to a specific command or form.

More information indicates there is additional or related information.

Need a hint used with activities and labs, provides a tip or hint for doing the exercises.

Keyboard Conventions
The following list outlines the abbreviations this document uses for keyboard keys and describes how to use them in combination. You can make some menu selections through the use of keyboard accelerators, which map menu selections to key combinations. ALT CTRL DEL ENTER ESC CTRL+z ESC,k Alternate key Control key Delete key Enter key Escape key To hold down the Control key and press Z. To press the Escape key, then K.

10

_ _______________
Terminology
Click To use a mouse or key combination to pick an item that begins an action. For example, Click Apply to save the changes. Select To mark an item by highlighting it with key combinations or by picking it with your cursor. Selecting does not initiate an action. After selecting an item, you click the action you want to affect the item. For example, Select the file original.dat from the list box, then click Delete to remove it from the directory. In addition, you would select items to define parameters, such as selecting toggle buttons. This also applies to selecting graphic elements from the design file. For example, Select the line string to define the graphic template. Tentative-select To place a tentative point on an existing graphic element in a design file. If you are using the CLIX operating system, you tentative-select by double-clicking with a mouse or pressing <T> on a hand-held cursor. If you are using the Windows NT operating system, you tentative-select by pressing a left-button, right-button chord. To select and execute a command by clicking the mouse or hand-held cursor button twice in rapid succession. This term implies that you are clicking the data button (<D>) as part of a menu or dialog box action. For example, Double-click on the file original.dat to load it into the new surface. Drag To press and hold the data button (<D>) while moving the mouse or hand-held cursor. To key a character string into a text box. To type in data and press ENTER to enter the data and execute the default action. In a dialog box, pressing TAB after keying in data will enter the data and move the cursor to the next field.

Preface

Double-click

Type Key in

11

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

12

_ _______________
1. Getting Started
The Express Project Creation program is a new feature that enables you to easily create projects using a predefined structure. Express Project Creation consists of two modes of operation New User and Advanced User. The Advanced User mode allows customization of the directory structure and distribution of the project files across multiple nodes. Express Project Creation is available only on Windows NT-based computers. It can create projects on computers that operate on either Windows NT or CLIX.

Getting Started

Getting Started

Project Setup Overview


A project is a convenient grouping of either all or part of the items that constitute a plant. The project is the fundamental structure for working in PDS. Each project contains all of the information that is required to work in a PDS task. A project and all of its accompanying files must be defined before you can use any of the other PDS modules. Setting up a project consists of the following steps: 1. Install the products. In addition to the operating system software, PDS requires that you have MicroStation, RIS, and a relational database set up. For information on installing software, see the PDS Project Setup Technical Reference. Also refer to the PD_Shell README.TXT file for information on product dependencies. Configure the system. This step includes setting up domain logins and setting up the networking environment. For information on system configuration, see the PDS Project Setup Technical Reference. Create project databases. The PD_Shell product includes scripts that automate the creation of the PDS databases for a number of database systems. These are located in the pdshell\sqls\ directory. Create the project. Start the Express Project Creation, and follow the steps outlined in the following chapters of this document. Define the reference data. Before you can begin working in your project, you must set up the reference data. This involves loading ASCII files that define components and specifications into the appropriate databases. These procedures are described in the PDS Project Setup Technical Reference and the PDS Reference Data Manager (PD_Data) Reference Guide.

2.

3.

4.

5.

13

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

Before You Begin


Before you can create a project, you must have first configured your system and installed the software. You will also need to create databases for each module of the PDS software to be used by your project. For example, for a project that will use the piping and equipment modules, you will need to create the project, design, and approved reference databases. For Express Project Creation, you will need to have PD_Lice and PD_Shell installed locally. (That is, they must be installed on the computer from which you plan to run the Express Project Creation program.) For New User mode, you will also need to have PD_Project, PD_Draw, PD_Data, PD_Eqp, and RD_USRDB or RD_DINRDB installed locally on the same disk partition. (A local installation means that the products are installed on the computer from which Express Project Creation is being run.) If the project will include both 2D and 3D data, the PDS2D software will also need to be installed locally. You will also need to install EE Raceway and FrameWorks Plus if your project will include these disciplines. If you are running Express Project Creation in Advanced User mode, you only need to have PD_Lice and PD_Shell installed locally. You can specify remote nodes where the other PDS modules have been loaded as a source location for the required libraries.

Starting the Program


To start the Express Project Creation program, double-click the Express Project Creation icon, which is located in the PD_Shell program group. The Project Options form is displayed.

14

_ _______________

Getting Started

Getting Started

Two modes are available for creating projects: New User and Advanced User

New User Mode


With New User mode, you can set up a project that follows a standard directory and database structure. The New User mode is ideal when your setup from one project to the next is consistent. This mode is the fastest way to set up a project, offering only minimal interaction once the process is started. The New User mode also provides an option to load sample data (models and drawings) into the created project. For information on creating a project using the New User option, see Creating a Standard Project, page 17. Use New User mode when any of the following conditions are true: Your project does not require a unique directory structure. You do not need to customize the relational data during project creation. You want to create a test or pilot project. You want to load a delivered sample dataset while creating the project.

15

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

Advanced User Mode


With Advanced User mode, you can customize the project as you are creating it. Not only can you specify a unique directory structure for the project files, but you can also have complete control over the structure of the data within the database. For information on creating a project using the Advanced User option, see Creating a Customized Project, page 27. Use Advanced User mode when any of the following conditions are true: Your project requires a unique directory structure. You need to customize the relational data. You want the ability to review and possibly change the settings read from the express.txt file.

16

_ _______________
2. Creating a Standard Project

Creating a Standard Project

The New User option enables you to create a project that follows a relatively simple, standard structure. Projects that are created using this option have the following directory structure:

New User

The system creates all the directories and subdirectories; you do not need to create the directory structure beforehand.

17

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 Each time you create a project, the express.txt file that was used to create the project is copied to the project directory. This enables you to keep a record of the specific parameters used for creating that project.

How to Use the New User Option


To create a project using the New User option, follow these steps: 1. On the Project Options form, set the User Level to New User. You are prompted to specify whether you want to load sample data. 2. Select Option Choose Yes to load sample project data (a small project that already contains plant items, such as piping, equipment, and so forth) or No to create a project that doesnt include sample data. If you choose Yes, the system loads a set of models and drawings into the created project. Refer to Appendix B for a description of the delivered sample data. If you load sample data, your plant monument is automatically set to 0,0,0. The available project disciplines are displayed. 3. Select Disciplines Select the disciplines that apply to your project. The available disciplines depend on the software you have loaded on the computer from which the Express Project Creation was started. These modules must be installed locally. Furthermore, they must all be installed on the same drive letter.

18

_ _______________

Creating a Standard Project

New User

4.

Accept or Select Other Discipline Once you have selected all required disciplines, choose Confirm to continue. The Define Project Data form is displayed.

19

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 5. On the Define Project Data form, key in the project number, project name, company name, job number, and plant name in the related fields. This information is stored in the Project Database and can be used in reports and other project documents. Also specify a design file in which project interferences are to be written. The default file name is your project name with .dgn appended to it. If your project includes a 2D discipline, key in a site name. The default site name is plant_name-project number. You can change the default name if needed. Be sure to press return as you enter information in each field. The project number determines the base directory name and the default schema names. 6. Accept or Provide Project Data Once you have specified all of the project data, choose Confirm to continue. The Define System Units form is displayed.

7.

Select Option On the Define System Units form, select the system of units English or Metric to be used for measuring distances in the model. You are prompted to specify the diameter units to be used for fittings and components.

20

_ _______________
8. Select Option If you chose to load sample data, the selections for system of units will determine the sample dataset to be loaded. You are prompted to specify whether or not you want to have plant monument information included in your project.

Creating a Standard Project

Select the Nominal Pipe Diameter (NPD) units English or Metric to be used for specifying pipe and fitting diameters in the model.

9.

Select Option Choose Yes to include Easting, Northing, or Elevation coordinates for the plant monument when the project is created. The plant monument is the center of the design volume for the plant; this point corresponds to the MicroStation position 0,0,0. Fields are displayed that enable you to specify the coordinates of the plant monument.

New User

OR Choose No to create the project without this information. 10. Accept or Select Option Once you have provided the necessary information, choose Confirm to continue. The Create Database Schemas form is displayed.

21

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

The selections that are available on this form vary depending on the disciplines chosen in Step 3. 11. Select Schemas On the Create Database Schemas form, specify the schemas to be created for your project. All of the required schemas are automatically selected for you. With the piping approved RDB schema and the EE RDB schema, you can choose to either create a new schema for your project or to attach to an existing schema. If you choose Use Existing Schema, a dialog box displays, which allows you to specify the existing project which contains reference data to share with the project being created. Select the project from the displayed form, and choose Confirm to continue. To create new schemas, select the Create New Schema option; then choose Confirm. The Create Project Control Schema form is displayed.

22

_ _______________

Creating a Standard Project

12.

The Create Project Control Schema form enables you to specify the parameters needed to build the schemas for your project. The information to be provided varies depending on the relational database being used. For each field, provide the following information: Network Protocol These fields indicate the types of network protocols used to access the database. For most Intergraph networks, you will use XNS or TCP. RIS uses the protocol at the top of the list as its primary protocol. Node Name or Address Key in the address of the node (workstation or server) to contain the database using the address format for the associated protocol (network address for XNS, internet address for TCP, and so forth). If you are creating the database on the local workstation, you can select Get Client Address to fill in these values. OS Type Select the end of the field and select the type of operating system for the database server: CLIX, VMS, or Windows NT. OS Username and Password For an Oracle database, key in the username and password to access the project schema. This must be the same username/password specified using the grant resource function. For a Sybase database, key in the username and password for a valid login to the database server. Database Username and Password For an Oracle database, key in the username and password to access the project schema. This must be the same username/password specified using the grant resource function. For an Informix database, key in the username and password of the PDS account on the database server. Database Name For Oracle, this is the SID name for the Oracle database. The SID name is defined when the database is created.

New User

23

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 For Informix, this is the same as the schema name as specified with the infxcreate statement. For Informix Standard Engine, key in the full directory path for the schema file (for example, c:\pdsproj\proj\pdproj). For Sybase, this is the same as the schema name as specified by the Sybase Create Database command. Database Management System Location Key in the directory path for the home directory of the database product (for example, c:\oracle or c:\informix). SQLEXEC Informix only. This field tells Informix which engine to run. It can be left blank unless Informix Standard Engine and On-line Engine are loaded on the same machine. DPTEMP Informix only. This field defines a directory where you want Informix to be create temporary files. The directory should be empty and must be created before creating the RIS schema. TBCONFIG Informix only. This field is used only if you have multiple copies of Informix running on the same system, each with its own tbconfig file. DSQUERY Sybase only. This field defines the database query listener (Sybase server name). SYBIFILE Sybase only. This field defines the interface file name. After you have specified all of the required information, choose Apply. The Create Project Control Schema form is dismissed, and the schema is created. If additional schemas are to be created, you are returned to Step 12. Otherwise, the Server Names & Drive Letters form is displayed.

24

_ _______________

Creating a Standard Project

New User

13.

On the Server Names & Drive Letters form, specify the node name of the file server on which the project is to reside. For Windows NT, key in the drive letter only (for example, D, without the colon). Be sure to press return to enter the data into each field. If your server runs on Windows NT and you want to create the project at a top-level drive (for example, c:\projname or e:\projname), you must first create a new share on the server for that drive and specify just the drive letter as the new share name. This is because the default Windows NT shares for the drive letters are available only to administrators. If you are running Express Project Creation on a client and specify that the project be located on a server, both the client and server nodes must be running the same version of Microstation. If the versions are different on the client and server, you will receive an Error updating seed files at the end of setup.

14.

Accept or Key in Data Once you have entered all of the node name and drive letter information, choose Confirm to continue. If your project includes structural data, the Create FrameWorks Sub-Project displays, and you continue to Step 15. Otherwise, the project is created, and the program exits.

25

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

15.

Key in Sub-Project Data On the Create FrameWorks Sub-Project form, specify the project number, the project name, the node name of the system and the directory on that system in which the FrameWorks information is to be stored, the force units for the subproject, and the name of the standard section table. Be sure to press return to enter the information in each field. When specifying the path, you must specify a full path name. Relative path names are not valid input for this field. Also, note that the directories for the structural sub-project are created such that the directory specified in the Sub-Project Number field is created as a subdirectory of the directory specified in the SubProject Path field.

16.

Accept or Modify Sub-Project Data Once you have specified all of the sub-project information, choose Confirm to continue. A dialog box is displayed indicating that the project was successfully created, and a log file named express.log is written in the project directory. If there are severe errors during the creation process, the system will try to clean up the database so that you can re-create the project after resolving the errors. No example specs are loaded for any of the sample projects. You must load specs in the specifications/material reference database before you can work in the new project.

26

_ _______________
3. Creating a Customized Project
The Advanced User option enables you to create a project with a customized database and/or file structure. Not only does this option enable you to specify a unique directory structure for all of the components that comprise a project, but it also enables you to customize working units, specify whether to use DBAcess for reporting, define unique locations for RDB data source files, and set up a project that shares or copies existing RDB data. Like the New User mode, Advanced User mode automates much of the work involved in setting up a project. But Advanced User mode differs from New User mode by allowing you to specify project creation parameters in the express.txt file. Furthermore, Advanced User mode enables you to confirm and modify these specifications interactively as the project is created. Advanced User combines the flexibility of the Create Project option in the PD_Project component with the convenience of a scripting file. For information on editing the express.txt file before starting the Advanced User mode, see Understanding the express.txt File, page 51.

Creating a Customized Project

How to Use the Advanced User Option


To create a project using the Advanced User option, follow these steps: 1. On the Project Options form, set the User Level to Advanced User. You are prompted to specify the name and location of the setup configuration file that is to be used to create the project. 2. Key in ASCII File Name, Node, and Path Key in the name of the scripting file (usually express.txt) to be used to create the project, the node name of the computer on which the file is located, and the path to the file. Be sure to press return to enter the information into each field. The default file name is express.txt. The file is delivered to the pdshell\seedz directory. The available project disciplines are displayed. 3. Select Disciplines Select the disciplines that apply to your project. The available disciplines depend on the software you have loaded on the computer from which the Express Project Creation was started. (These modules do not necessarily have to reside on the computer; they can be installed in a client configuration.)

Advanced User

27

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

4.

Accept or Select Other Discipline Once you have selected all required disciplines, choose Confirm to continue. The Define Project Data form is displayed.

28

_ _______________
5.

Creating a Customized Project

On the Define Project Data form, key in the project number, project name, company name, job number, and plant name in the related fields. Also specify a design file in which project interferences are to be written. The default file name is your project name with .dgn appended to it. If your project includes a 2D discipline, key in a site name. The default site name is plant_name-project number. You can change the default name if needed. Be sure to press return as you enter information in each field. The project number determines the base directory name and the default schema names.

6.

Accept or Provide Project Data Once you have specified all of the project data, choose Confirm to continue. The Define System Units form is displayed.

Advanced User

7.

Select Option On the Define System Units form, select the system of units English or Metric to be used for measuring distances in the model. You are prompted to specify the diameter units to be used for fittings and components.

29

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 8. Select Option Select the Nominal Pipe Diameter (NPD) units English or Metric to be used for specifying pipe and fitting diameters in the model. You are prompted to specify whether or not you want to have plant monument information included in your project.

9.

Select Option Choose Yes to include Easting, Northing, or Elevation coordinates for the plant monument when the project is created. Fields are displayed that enable you to specify the coordinates of the plant monument.

OR Choose No to create the project without this information, and go to Step 11. 10. Key in coordinates for the plant monument in the Easting, Northing, and Elevation fields. Be sure to press return as you enter information in each field. You are prompted to specify whether you want to modify the project working units for the piping and equipment models.

11.

Select Option Choose Yes if you want to modify the working units or No if you want to accept the default working units.

30

_ _______________
12. Accept or Select Option Choose Confirm to continue. If you specified that you wanted to modify the working units, the Revise Working Units form is displayed. If you chose not to modify working units, go to Step 15.

Creating a Customized Project

13.

On the Revise Working Units form, enter the UORs per subunit (SU) in the available field. Then select the field name that you want reflected in your project. The default English working units are 2032 UORs per subunit. For Metric projects, the default working units are 80 UORs per subunit. The field name selections that are available depend on whether you specified English or Metric working units. The number of positional units per subunit should not be revised to be less than 635 PU per inch (English units) or 25 PU per mm (metric units). The software updates the piping, equipment, and drawing seed files to reflect the change to the working units. The working units in the drawing seed file will be updated to be 96 times the number of positional units per subunit that you specified for the models. All of the models that will be referenced in the project (for example, structural, architectural, and so forth) will need to have the same working units as the piping and equipment models.

Advanced User

14.

Accept or Select Option Choose Confirm to continue.

31

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 The Create Database Schemas form is displayed.

15.

On the Create Database Schemas form, specify the schemas to be created for your project. All of the required schemas are automatically selected for you. With the piping approved RDB schema and the EE RDB schema, you can choose to either create a new schema for your project or to attach to an existing schema. If you choose Use Existing Schema, a dialog box displays, allowing you to specify the existing project that contains reference data to share with the project being created. Select the project from the displayed form, and choose Confirm to continue. To create new schemas, select the Create New Schema option and then choose Confirm. The Create Project Control Schema form is displayed.

32

_ _______________
16. The Create Project Control Schema form enables you to specify the parameters needed to build the schemas for your project. For each field, provide the following information: Network Protocol These fields indicate the types of network protocols used to access the database. For most Intergraph networks, you will use XNS or TCP. RIS uses the protocol at the top of the list as its primary protocol. Node Name or Address Key in the address of the node (workstation or server) to contain the database using the address format for the associated protocol (network address for XNS, internet address for TCP, and so forth). If you are creating the database on the local workstation, you can select Get Client Address to fill in these values. OS Type Select the end of the field and select the type of operating system for the database server: CLIX, VMS, or Windows NT.

Creating a Customized Project

OS Username and Password For an Oracle database, key in the username and password to access the project schema. This must be the same username/password specified using the grant resource function. For a Sybase database, key in the username and password for a valid login to the database server. Database Username and Password For an Oracle database, key in the username and password to access the project schema. This must be the same username/password specified using the grant resource function. For an Informix database, key in the username and password of the PDS account on the database server.

Advanced User

Database Name For Oracle, this is the SID name for the Oracle database. The SID name is defined when the database is created. For Informix, this is the same as the schema name as specified with the infxcreate statement. For Informix Standard Engine, key in the full directory path for the schema file (for example, c:\pdsproj\proj\pdproj). For Sybase, this is the same as the schema name as specified by the Sybase Create Database command. Database Management System Location Key in the directory path for the home directory of the database product (for example, c:\oracle or c:\informix). SQLEXEC Informix only. This field tells Informix which engine to run. It can be left blank unless Informix Standard Engine and On-line Engine are loaded on the same machine.

33

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 DPTEMP Informix only. This field defines a directory where you want Informix to be create temporary files. The directory should be empty and must be created before creating the RIS schema. TBCONFIG Informix only. This field is used only if you have multiple copies of Informix running on the same system, each with its own tbconfig file. DSQUERY Sybase only. This field defines the database query listener (Sybase server name). SYBIFILE Sybase only. This field defines the interface file name. After you have specified all of the required information, choose Apply. The Create Project Control Schema form is dismissed, and the schema is created. If additional schemas are to be created, you are returned to Step 16. Otherwise, the Database Customization Options form is displayed. The first field enables you to specify whether or not you want to revise the piping design database structure.

17.

Select Option Choose Yes to modify the structure. The Database Structure Revision form is displayed.

34

_ _______________

Creating a Customized Project

OR Choose No to accept the default structure, and go to Step 32. 18. Identify Table for Modification The Database Structure Revision form enables you to modify certain attribute lengths, add user-defined attributes, define attributes to be displayed, or define attributes to be case sensitive. Select the table to be modified from the display on the left side of the form. The modifiable attributes for the selected table are displayed.

Advanced User

19.

Modify Lengths or Select Other Option Select the attribute you want to change. Then key in a number within the displayed range to specify the length of the attribute.

35

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 20. You can select User Defined Attributes to add additional attributes to the selected table. If you cannot add additional attributes to the selected table, a warning message is displayed.

21.

Enter Attribute Name Key in the description for the new attribute. Be sure to press return to enter the description.

22.

Select Attribute Type Select the attribute type for the specified attribute: Decimal, Integer, Short Integer, Alphanumeric, or Standard Note. If you select Alphanumeric, you must also specify the number of characters. If you select Standard Note, you must also key in the number of the code list set.

23.

Accept Attribute Data or Modify Choose Confirm to post the newly defined attribute to the top part of the form.

24.

Enter Attribute Name or Exit Return to Step 21 to define another attribute. OR

Choose Cancel to return to the Database Structure Revision form. 25. You can select Attributes to be Displayed to define the attributes within the selected table to be displayed or not displayed for database operations.

36

_ _______________
The available fields redisplay to list the attributes for the selected table.

Creating a Customized Project

26.

Select Attributes to NOT be Displayed From the list, select the attributes that you do not want to be displayed.

27.

Accept or Select Additional Attributes Select additional attributes as needed. Then choose Confirm to accept the displayed information.

Advanced User

The Database Structure Revision form is redisplayed. 28. You can select Attributes to be Case Insensitive to define the attributes within the selected table to be case insensitive for database operations. Attributes that are identified as case insensitive are treated as uppercase regardless of the case entered during data input. The available fields redisplay.

37

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

29.

Select Attributes to be CASE INSENSITIVE From the displayed list of attributes, select one that you want to be case insensitive. The selected attributes will have their alphanumeric data automatically converted to uppercase in the following situations: When a row is being created in the database. When a row is being updated in the database. When a value for such a column in a table is being used as search criteria for a database query. Alphanumeric data that is to be transferred from the P&ID Database to the Piping Design Database must be defined consistently in terms of case sensitivity for both databases for successful data transfer and comparison. Presently all alphanumeric data, with the following exceptions, is considered to be case sensitive. The following alphanumeric data is always considered to be uppercase and cannot be changed: Piping materials class. Schedule/thickness. Pressure rating.

38

_ _______________
Commodity code. Any attributes that are designated as case insensitive will have their data type changed from character to upper_case in the design.ddl file in the project directory. If, after creating the project, you determine that an attribute was inadvertently selected or not selected for case insensitivity, you can edit the design.ddl file manually to reverse the selection. However, this will not update any previously created data. 30. Accept or Select Additional Attributes Select additional attributes as needed. Then choose Confirm to accept the displayed information. The Database Structure Revision form is redisplayed. 31.

Creating a Customized Project

Once you have made all necessary database revisions, choose Confirm to continue. The Database Customization Options form redisplays, and you are prompted to specify whether or not you want to use DBAccess for reporting.

Advanced User

32.

Select Option Select Yes to add the database structure necessary to support DBAccess reporting. OR Select No if you will be using some other reporting tool.

39

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 33. Select Option If your project includes the EE Raceway discipline, you are prompted to specify whether or not you want to customize the EE project database. Choose Yes to customize the database. Additional fields display for you to specify the SQL File Name and the Command File Name, as well as the Node Name and the Path (of the system on which the SQL and command files reside).

OR Select No to continue without customizing the EE project database. The .sql and .cmd files in the eerway\db directory are used to setup the database. 34. Accept or Select Option Choose Confirm to continue. The Define RDB File Locations form is displayed. You are prompted to specify whether or not you want to have nonexisting directories created as needed.

40

_ _______________

Creating a Customized Project

35.

Select Option Select Yes to allow the program to create directories as needed. OR Select No to use only existing directories. Additional fields are displayed for you to specify how your 3D RDB data is to be built.

Advanced User

41

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

36.

Select Option Select one of the following options: Define Location for New RDB Specifies the path names for the reference data libraries, but does not copy any of the libraries to the specified directory. This option updates the pdtable_102 entries; this is the option to use if you want to create new libraries. This option enables you to build a new RDB or point to reference data that already exists on the file server, but which is not associated with an existing project. Share RDB with Existing Project Enables you to share reference data with an existing project. Like the Define Location for New RDB option, this option also updates the pdtable_102 entries without copying the libraries. However, it updates the entries to match those defined in an existing project rather than reading the library locations from the express.txt file. When you select this option, a list of existing projects is displayed for you to specify the project with which RDB data is to be shared. Copy Existing RDB to New Project Enables you to copy reference data from an existing project to the new project. This option updates the pdtable_102 entries for the libraries and also copies the files from the source directory to the specified output location. The source directory is defined by the location of all the libraries in the existing project. When you select this option, a list of existing projects is displayed for you to specify the project from which RDB data is to be copied.

42

_ _______________
Copy RDB Data Enables you to copy reference data to the new project. This option updates the pdtable_102 entries for the libraries and also copies the files from the source directory specified in the express.txt file to the specified output location. You are prompted to specify whether or not you want to share report format/search criteria with an existing project.

Creating a Customized Project

37.

Select Option Choose Yes to use existing report format and search criteria. A list of existing projects is displayed for you to to specify the project including the report specifications to be shared.

Advanced User

OR Choose No to use the delivered report specifications, and go to Step 39. 38. Double-click to select a project from the displayed list. If your project includes any of the 2D disciplines, additional fields are displayed for you to specify how your 2D RDB data is to be built.

43

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

39.

Select Option Select one of the following options: Define Location for New RDB Specifies the path names for the reference data libraries, but does not copy any of the libraries to the specified directory. This option enables you to point to reference data that already exists on the file server, but which is not associated with an existing project. Share RDB with Existing Project Enables you to share reference data with an existing project. When you select this option, a list of existing projects is displayed for you to specify the project with which RDB data is to be shared. Copy Existing RDB to New Project Enables you to copy reference data from an existing project to the new project. The source directory is defined by the location of all the libraries in the existing project. When you select this option, a list of existing projects is displayed for you to specify the project from which RDB data is to be copied. Copy Delivered RDB Data to New Project Enables you to copy delivered reference data to the new project.

40.

Accept or Select Option Choose Confirm to continue. If you chose the Define Location for New RDB option, the Define Location for New RDB form is displayed. Go to Step 41.

44

_ _______________
If you chose the Copy RDB Data option, the Copy 3D RDB to New Project form is displayed. Go to Step 42. If you chose Share RDB with Existing Project or Copy Existing RDB to New Project, and your project includes any of the 2D disciplines, the Define 2D Reference Data Locations form is displayed, and you go to Step 43. Otherwise, go to Step 44. 41. Accept or Update File Name, Node Name, and File Path

Creating a Customized Project

On the Define Location for New RDB form, use the scroll bars to review the displayed data. The default nodes and paths are read from the express.txt file used to create the project. To change the node name and path for one file, simply click on the field you want to edit and key in revised information. You can change all of the node names by selecting the Change Node Names To field and keying in a new node name. The Substitute Root Paths From/To fields enable you to change groups of pathnames. If you choose not to define a specific library, space through the fields for the file name, node, and path. Be sure to press Return in each field. Once you have defined the reference data to be used to create the reference data for the new project, choose Confirm to continue. If the program is unable to locate a specified file, a message box is displayed. When you close the message box, the file that caused the problem is highlighted in red. Edit the data as necessary, and choose Confirm to continue.

Advanced User

45

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 If your project includes any of the 2D disciplines, the Define 2D Reference Data Location form is displayed, and you go to Step 43. Otherwise, the Copy Files to Project Directory form is displayed, and you go to Step 44. 42. Accept or Update File Name, Node Name, and File Path

The Copy 3D RDB to New Project form displays the source (where you want the files copied from) and destination (where you want the files copied to) for the reference data. The default nodes and paths are read from the express.txt file used to create the project. Use the scroll bars to review the displayed data. To change the node name and path for one file, simply click on the field you want to edit and key in the revised information. You can change all of the source node names by selecting the Change Source Node Names To field and entering a new node name. The Substitute Source Root Paths From/To fields enable you to change groups of source pathnames. Similarly, the Change Destination Node Names To and Substitute Destination Root Paths From/To fields enable you to change groups of destination node names and pathnames for the new project. Once you have defined the reference data to be used in the new project, choose Confirm to continue. If the program is unable to locate a specified file, a message box is displayed. When you close the message box, the file that caused the problem is highlighted in red. Edit the data as necessary, and choose Confirm to continue.

46

_ _______________
The Copy Files to Project Directory form is displayed. 43. Accept or Update Node Name and File Path

Creating a Customized Project

The Define 2D Reference Data Location form displays the destination (where you want the delivered files copied to) for the 2D reference data. The default nodes and paths are read from the express.txt file used to create the project. Use the scroll bars to review the displayed data. To change the node name and path for one file, simply click on the field you want to edit and key in the revised information. You can change all of the node names by selecting the Change Node Names To field and entering a new node name. The Substitute Root Paths From/To fields enable you to change groups of pathnames. Once you have defined the reference data to be used in the new project, choose Confirm to continue. If the program is unable to locate a specified file, a message box is displayed. When you close the message box, the file that caused the problem is highlighted in red. Edit the data as necessary, and choose Confirm to continue. The Copy Files to Project Directory form is displayed. 44. Accept or Update Node Name and File Path

Advanced User

47

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

The Copy Files to Project Directory form displays a list of files to be copied to your project. The File Description and File Name fields are not editable. The file descriptions match the keywords in the express.txt file. Use the scroll bars to review the displayed information. The Node and Path columns reflect the values read from the express.txt file that was used to create the project. You can change the Node and Path specifications for an individual file by clicking on the field you want to change and entering the revised information. To change all of the nodes, select the Change Node Names To field, and enter the new node name. The Substitute Root Paths From/To fields enable you to quickly change groups of pathnames. Once you have defined the location of the project files to be used to create the new project, choose Confirm to continue. If the program is unable to locate a specified file, a message box is displayed. When you close the message box, the file that caused the problem is highlighted in red. Edit the data as necessary, and choose Confirm to continue. The Define Default Miscellaneous File Locations form is displayed.

48

_ _______________

Creating a Customized Project

45.

Accept or Update Node Name and File Path The Define Default Miscellaneous File Locations form is much like the Copy Files to Project Directory form. Instead of dealing primarily with seed, border, category, and configuration files, the Define Default Miscellaneous File Locations form establishes the location for a variety of files that are specific to certain PDS modules. The File Description and File Name fields are not editable. The file descriptions match the keywords in the express.txt file. Use the scroll bars to review the displayed information. The Node and Path columns reflect the values read from the express.txt file that was used to create the project. You can change the Node and Path specifications for an individual file by clicking on the field you want to change and entering the revised information. To change all of the nodes, select the Change Node Names To field, and enter the new node name. The Substitute Root Paths From/To fields enable you to quickly change groups of pathnames. Once you have defined the location of the project files to be used to create the new project, choose Confirm to continue. If the program is unable to locate a specified file, a message box is displayed. When you close the message box, the file that caused the problem is highlighted in red. Edit the field as necessary, and choose Confirm to continue.

Advanced User

49

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 If your project includes structural data, the Create FrameWorks Sub-Project form is displayed, and you continue to Step 40. Otherwise, the project is created, and the program exits.

46.

Key in Sub-Project Data On the Create FrameWorks Sub-Project form, specify the project number, the project name, the node name of the system, the directory in which the FrameWorks information is to be stored, the force units for the sub-project, and the name of the standard section table. Be sure to press return to enter the information in each field. When specifying the path, you must specify a full path name. Relative path names are not valid input for this field. Also, note that the directories for the structural sub-project are created such that the directory specified in the Sub-Project Number field is created as a subdirectory of the directory specified in the SubProject Name field.

47.

Accept or Modify Sub-Project Data Once you have specified all of the sub-project information, choose Confirm to continue. A dialog box is displayed indicating that the project was successfully created, and a log file named express.log is created in the project directory. If there are severe errors during the creating process, the system will try to clean up the database so that you can re-create the project after resolving the errors.

50

_ _______________
4. Understanding the express.txt File
The express.txt file enables you to customize the way a project is created. This file is read whether you create a project using the New User mode or the Advanced User mode. With Advanced User mode, you can modify the file settings as you create the project; in New User mode, many of the settings in the express.txt file are inferred from responses made to the various prompts and fields displayed during the process. In the New User mode, the express.txt file that is located in the \win32app\ingr\pdshell\seedz directory is read, and the project is created using the directory structure specified. The express.txt file is then copied to the project directory. You cannot edit this file. You can only edit copies of this file, and these customized files can only be used in Advanced User mode. In the Advanced User mode, you can use a specific express.txt file. This file can be located in any directory on any computer recognized through the network by your computer. It can also have any file name. Its contents, however, must follow the structure of the delivered express.txt file. The express.txt file uses primary and secondary keywords to set variables needed to create a project. Primary keywords are on a line by themselves and are followed by a colon (:). You cannot edit primary keywords. Secondary keywords set the variable data. Secondary keywords are always followed by an equal sign (=). You can edit the information on the right side of the equal sign to be the value you want, but you cannot change the keyword. That is, you can change the value for the keyword, but not the keyword itself. Comments information in the file added solely to help with the readability of the file are also included; text that is on a line beginning with an exclamation point (!) is a comment.

Understanding the express.txt File

In New User mode, information in the file is replaced either by information that you key in (through the forms interface) or by information from the system registry. For example, the delivered express.txt file uses software_node to describe the node name of the computer on which the PDS software resides. This text is replaced by the values read from the system registry. (This information is added to the system registry whenever you install software.) Other information, such as the value for file_server_node (the node name of the computer on which the project data resides), is replaced by the node name you enter on the Server Names & Drive Letters form. For a complete printout of the delivered express.txt file, see Appendix A.

express.txt

51

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 The express.txt file contains the following major sections: Specifications for seed data. Specifications for default file locations. Specifications for approved and unapproved RDB libraries. Specifications for drawing cell libraries. Specifications for the location of 2D reference data.

Seed Data
Piping_Seed_Model Specifies the node name and directory of the seed file for piping models . Equipment_Seed_Model Specifies the node name and directory of the seed file for equipment models. Raceway_Seed_Model Specifies the node name and directory of the seed file for raceway models. Default_Seed_Drawing Specifies the node name and directory of the default piping drawing seed file. Alternate_Seed_Drawing Specifies the node name and directory for the alternate drawing seed files. There is a separate entry for each drawing type. Orthographic_Drawing_Plot_Size_Table Specifies the node name and directory of the plot size table for orthographic drawings (drawplotsize). Drawing_Cell_Library Specifies the node name and directory of the drawing cell libraries (drawing.cel). Drawing_Labels_per_Object_Type Specifies the node name and directory of the drawing labels. There is a separate entry for each drawing type (labels.***, where *** is the drawing type number, such as 643 for Equipment Arrangements). Instrument_Objects_for_Drawing_Annotation Specifies the node name and directory for the instrument objects that are used for annotating drawings (in_object.dwg). Equipment_Objects_for_Drawing_Annotation Specifies the node name and directory for the equipment objects that are used for annotating drawings (eqp_object.dwg).

52

_ _______________
Label_Button_for_Drawing_Annotation Specifies the node name and directory for the ASCII file that defines the label placement form for the Drawing Mass Annotation command (lab_button.dwg). Equipment_Centerline_Definitions_for_Drawings Specifies the node name and directory for the equipment centerlines file (eqp_center.dwg).

Understanding the express.txt File

Clash_Plot_Cell_Library Specifies the node name and directory for the cell library to be used for clash reports (clash_plot.cel). Clash_Plot_Border Specifies the node name and directory for the border file to be used for clash reports (borderifc.dgn). Clash_Plot_Settings Specifies the node name and directory for the settings file for plotting clashes (ifc.i). Piping_Model_Category_Descriptions_by_NPD Specifies the node name and directory for the file that sorts piping category descriptions by nominal pipe diameter (pipecats1.txt). Piping_Model_Category_Descriptions_by_Fluid_Code Specifies the node name and directory for the file that sorts piping category descriptions by fluid code (pipecats2.txt). Drawing_Category_Descriptions Specifies the node name and directory of the drawing category descriptions file. (drwcats.txt). FrameWorks_Category_Descriptions Specifies the node name and directory of the FrameWorks category descriptions file (framewks.txt). ModelDraft_Category_Descriptions Specifies the node name and directory of the ModelDraft category descriptions file (symbology.sms). Raceway_Configuration_File Specifies the node name and directory of the Raceway configuration file (ee.cfg). PID_to_Piping_NPD_Equivalent_Table Specifies the node name and directory of the nominal pipe diameter equivalent table for P&ID-to-Piping data transfer (pid_npd_equiv). PID_to_Piping_Correlation_Table Specifies the node name and directory of the correlation table used for the P&ID-to-Piping data transfer (pid_to_piping). Queue_Description_Library Specifies the node name and directory for the queue descriptions file (queue_descript). RDB_Option_File Specifies the node name and directory of the reference database options file used by the Interactive Spec Writer command (RDB_options).

express.txt

53

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 Standard_Note_Maximum_Length_Table Specifies the node name and directory of the maximum length table for standard notes (stnote_max_len). Spec_Order_Maximum_Length_Table Specifies the node name and directory of the file that contains the table of specification attribute orders and their related maximum lengths (spec_order.max).

Default File Locations


PDS_Project_Directory Specifies the node name and directory for the PDS project directory. Raceway_Project_Directory Specifies the node name and directory for the raceway data. Piping_Models Specifies the node name and directory for the piping models. Equipment_Models Specifies the node name and directory for the equipment models. HVAC_Models Specifies the node name and directory for the HVAC models. Architectural_Models Specifies the node name and directory for the architectural models. Orthographic_Drawings_by_Drawing_Type Specifies the node name and directory for the orthographic drawings, ordered by drawing type. There is one entry for each drawing type. Drawing_Borders Specifies the node name and directory for drawing borders. Piping_Eden_Source Specifies the default location (node name and directory) for the Eden source files. Dimension_or_Spec_Table_Source Specifies the default location (node name and directory) for the Dimension Table and Spec Table source files. Piping_Spec_Source Specifies the default location (node name and directory) for the neutral files to be used to load the Specification/Material Reference Database and Material Description Libraries. Piping_Assembly_Source Specifies the default location (node name and directory) for the Piping Assembly Language source files. Standard_Note_Library_Source Specifies the default location (node name and directory) for Standard Note (code list) source files.

54

_ _______________
Equipment_Eden_Source Specifies the default location (node name and directory) for the Equipment Eden source files. TDF_Table_Source Specifies the default location (node name and directory) for Equipment table definition files. Model_Builder_Source Specifies the default location (node name and directory) for model builder language source files. Design_Review_Model Specifies the node name and directory for DesignReview models and tags. Reports Specifies the node name and directory for MTO reports. Report_Formats Specifies the node name and directory for report format files. Report_Discrimination_Data Specifies the node name and directory for report discrimination data. Report_Search_Criteria_Data Specifies the node name and directory for report search criteria data.

Understanding the express.txt File

Clash_Reports Specifies the node name and directory for interference clash plot reports. Clash_Plots Specifies the node name and directory for interference design files. Equipment_IForms Specifies the node name and directory for the forms used by the PD_Eqp (Equipment) module.

RDB Libraries
A_Standard_Note_Library Specifies the node name, directory, and file name for the approved standard note library. U_Standard_Note_Library Specifies the node name, directory, and file name for the unapproved standard note library.

express.txt

A_Label_Description_Library Specifies the node name, directory, and file name for the approved label description library. U_Label_Description_Library Specifies the node name, directory, and file name for the unapproved label description library. A_Piping_Assembly_Library Specifies the node name, directory, and file name for the approved piping assembly library.

55

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 U_Piping_Assembly_Library Specifies the node name, directory, and file name for the unapproved piping assembly library. A_Graphic_Commodity_Library Specifies the node name, directory, and file name for the approved graphic commodity library. U_Graphic_Commodity_Library Specifies the node name, directory, and file name for the unapproved graphic commodity library. A_Piping_Spec_Job_Table_Library Specifies the node name, directory, and file name for the approved piping specification job table library. U_Piping_Spec_Job_Table_Library Specifies the node name, directory, and file name for the unapproved piping specification job table library. A_US_Physical_Data_Library Specifies the node name, directory, and file name for the approved U.S. physical data library. U_US_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved U.S. physical data library. A_DIN_Physical_Data_Library Specifies the node name, directory, and file name for the approved DIN physical data library. U_DIN_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved DIN physical data library. A_British_Standard_Physical_Data_Library Specifies the node name, directory, and file name for the approved British standard physical data library. U_British_Standard_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved British standard physical data library. A_European_A_Physical_Data_Library Specifies the node name, directory, and file name for the approved European A physical data library. U_European_A_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved European A physical data library. A_European_B_Physical_Data_Library Specifies the node name, directory, and file name for the approved European B physical data library. U_European_B_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved European B physical data library. A_JIS_Physical_Data_Library Specifies the node name, directory, and file name for the approved JIS physical data library.

56

_ _______________
A_Australian_Physical_Data_Library Specifies the node name, directory, and file name for the approved Australian physical data library. U_Australian_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved Australian physical data library. A_International_A_Physical_Data_Library Specifies the node name, directory, and file name for the approved International A physical data library. U_International_A_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved International A physical data library. A_International_B_Physical_Data_Library Specifies the node name, directory, and file name for the approved International B physical data library. U_International_B_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved International B physical data library. A_Company_Practice_Physical_Data_Library Specifies the node name, directory, and file name for the approved company practice physical data library. U_Company_Practice_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved company practice physical data library. A_Short_Material_Description_Library Specifies the node name, directory, and file name for the approved short material description library. U_Short_Material_Description_Library Specifies the node name, directory, and file name for the unapproved short material description library. A_Long_Material_Description_Library Specifies the node name, directory, and file name for the approved long material description library.

Understanding the express.txt File

U_JIS_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved JIS physical data library.

express.txt

U_Long_Material_Description_Library Specifies the node name, directory, and file name for the unapproved long material description library. A_Specialty_Material_Description_Library Specifies the node name, directory, and file name for the approved specialty material description library. U_Specialty_Material_Description_Library Specifies the node name, directory, and file name for the unapproved specialty material description library.

57

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 A_Equipment_Graphic_Commodity_Library Specifies the node name, directory, and file name for the approved equipment graphic commodity library. U_Equipment_Graphic_Commodity_Library Specifies the node name, directory, and file name for the unapproved equipment graphic commodity library. A_Equipment_Tutorial_Definition_Library Specifies the node name, directory, and file name for the approved equipment tutorial definition library. U_Equipment_Tutorial_Definition_Library Specifies the node name, directory, and file name for the unapproved equipment tutorial definition library. A_Equipment_Physical_Data_Library Specifies the node name, directory, and file name for the approved equipment physical data library. U_Equipment_Physical_Data_Library Specifies the node name, directory, and file name for the unapproved equipment physical data library. A_Equipment_Cell_Library Specifies the node name, directory, and file name for the approved equipment cell library. U_Equipment_Cell_Library Specifies the node name, directory, and file name for the unapproved equipment cell library.

Drawing Cell Libraries


Drawing_Cell_Library_by_Drawing_Type Specifies the node name, directory, and file name of the source and destination, ordered by drawing type. There is a separate entry for each drawing type.

2D Reference Data
PDS2D_Reference_Data Specifies the node name and directory for the 2D reference data. PID_Reference_Data Specifies the node name and directory for the P&ID reference data. PFD_Reference_Data Specifies the node name and directory for the PFD reference data.

58

_ _______________
Appendix A:

The express.txt File

Appendix A The express.txt File


Appendix A
The following express.txt file is delivered as part of the Express Project Creation program:
! This is the default ASCII file used by Express Setup. ! Primary keywords must end with a colon (:). ! Secondary keywords must include equals ( = ), and are indented | for clarity. ! The following are logical node names that have been used. In new user ! mode, these logical names will be automatically replaced by inputs from ! the user. ! software_node ! file_server_node ! design_review_node ! ! ! ! ! ! ! ! ! ! ! ! ! == == == node name of location for PDS products node name of file server for PDS project node name of DesignReview workstation

The following are logical drive letters that have been used. In new user mode, these logical names will be automatically replaced by inputs from the user. Likewise, the \pds root path will be automatically replaced by the project number. pds_product pds_project_data pds_model_data pds_dwg_data pds_3d_rdb_data pds_report_data pds_clash_data pds_review_data pds_2d_rdb_data == == == == == == == == == drive drive drive drive drive drive drive drive drive letter letter letter letter letter letter letter letter letter of of of of of of of of of location location location location location location location location location for for for for for for for for for PDS products PDS project data PDS model data PDS drawing data PDS 3D reference data PDS report data PDS clash data DesignReview data PDS 2D reference data

!\ ! Source for Seed Data to be Copied to PDS Project Directory !/ Piping_Seed_Model: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Equipment_Seed_Model: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Raceway_Seed_Model: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\eerway\dgn\seed Default_Seed_Drawing: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Foundation Location Drawings Drawing_Type = 535 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz

59

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
Alternate_Seed_Drawing: ! Piling Drawings Drawing_Type = 537 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Structural Perspectives, Plans, Sections and Details Drawing_Type = 540 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Plot Plans Drawing_Type = 641 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Equipment Arrangement Drawings Drawing_Type = 643 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Piping Underground Drawings Drawing_Type = 651 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Equipment Orientations Drawing_Type = 661 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Piping One Line Drawings Drawing_Type = 663 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Piping Perspectives, Plans, Sections and Details Drawing_Type = 665 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Pipeline Alignment Drawings Drawing_Type = 667 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Instrument Location Plans Drawing_Type = 731 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz

60

_ _______________
Appendix A:
Alternate_Seed_Drawing: ! Electrical Area Classification Drawings Drawing_Type = 841 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Electrical Underground Drawings Drawing_Type = 851 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! Lighting Perspectives, Plans, Sections and Details Drawing_Type = 865 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Alternate_Seed_Drawing: ! HVAC Perspectives, Plans, Sections and Details Drawing_Type = 971 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\seedz Orthographic_Drawing_Plot_Size_Table: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\plot Drawing_Cell_Library: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Drawing_Labels_per_Object_Type: ! Foundation Location Drawings Drawing_Type = 535 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Piling Drawings Drawing_Type = 537 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Structural Perspectives, Plans, Sections and Details Drawing_Type = 540 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Plot Plans Drawing_Type = 641 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Equipment Arrangement Drawings Drawing_Type = 643 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample

The express.txt File

Appendix A

61

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
Drawing_Labels_per_Object_Type: ! Piping Underground Drawings Drawing_Type = 651 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Equipment Orientations Drawing_Type = 661 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Piping One Line Drawings Drawing_Type = 663 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Piping Perspectives, Plans, Sections and Details Drawing_Type = 665 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Pipeline Alignment Drawings Drawing_Type = 667 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Instrument Location Plans Drawing_Type = 731 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Electrical Area Classification Drawings Drawing_Type = 841 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Electrical Underground Drawings Drawing_Type = 851 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! Lighting Perspectives, Plans, Sections and Details Drawing_Type = 865 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Drawing_Labels_per_Object_Type: ! HVAC Perspectives, Plans, Sections and Details Drawing_Type = 971 Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample

62

_ _______________
Appendix A:
Instrument_Objects_for_Drawing_Annotation: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Equipment_Objects_for_Drawing_Annotation: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Label_Button_for_Drawing_Annotation: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Equipment_Centerline_Definitions_for_Drawings: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddraw\sample Clash_Plot_Cell_Library: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Clash_Plot_Border: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\border Clash_Plot_Settings: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\plot Piping_Model_Category_Descriptions_by_NPD: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\categ Piping_Model_Category_Descriptions_by_Fluid_Code: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\categ Drawing_Category_Descriptions: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\categ FrameWorks_Category_Descriptions: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\categ ModelDraft_Category_Descriptions: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\categ Raceway_Configuration_File: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\eenuc PID_to_Piping_NPD_Equivalent_Table: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\pid PID_to_Piping_Correlation_Table: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\pid

The express.txt File

Appendix A

63

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
Queue_Description_Library: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\plot RDB_Option_File: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddata\sample\data Standard_Note_Maximum_Length_Table: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Spec_Order_Maximum_Length_Table: ! Copied to Piping_Spec_Source - not Project Directory Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pddata\sample\format !\ ! Default File Locations !/ PDS_Project_Directory: Node = file_server_node Path = pds_project_data:\pds\project Raceway_Project_Directory: Node = file_server_node Path = pds_model_data:\pds\raceway Piping_Models: Default_Node = file_server_node Default_Path = pds_model_data:\pds\models\piping Equipment_Models: Default_Node = file_server_node Default_Path = pds_model_data:\pds\models\eqp HVAC_Models: Default_Node = file_server_node Default_Path = pds_model_data:\pds\models\hvac Architectural_Models: Default_Node = file_server_node Default_Path = pds_model_data:\pds\models\arch Orthographic_Drawings_by_Drawing_Type: ! Foundation Location Drawings Drawing_Type = 535 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\535 Orthographic_Drawings_by_Drawing_Type: ! Piling Drawings Drawing_Type = 537 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\537 Orthographic_Drawings_by_Drawing_Type: ! Structural Perspectives, Plans, Sections and Details Drawing_Type = 540 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\540

64

_ _______________
Appendix A:
Orthographic_Drawings_by_Drawing_Type: ! Plot Plans Drawing_Type = 641 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\641 Orthographic_Drawings_by_Drawing_Type: ! Equipment Arrangement Drawings Drawing_Type = 643 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\643 Orthographic_Drawings_by_Drawing_Type: ! Piping Underground Drawings Drawing_Type = 651 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\651 Orthographic_Drawings_by_Drawing_Type: ! Equipment Orientations Drawing_Type = 661 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\661 Orthographic_Drawings_by_Drawing_Type: ! Piping One Line Drawings Drawing_Type = 663 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\663 Orthographic_Drawings_by_Drawing_Type: ! Piping Perspectives, Plans, Sections and Details Drawing_Type = 665 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\665 Orthographic_Drawings_by_Drawing_Type: ! Pipeline Alignment Drawings Drawing_Type = 667 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\667 Orthographic_Drawings_by_Drawing_Type: ! Instrument Location Plans Drawing_Type = 731 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\731 Orthographic_Drawings_by_Drawing_Type: ! Electrical Area Classification Drawings Drawing_Type = 841 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\841 Orthographic_Drawings_by_Drawing_Type: ! Electrical Underground Drawings Drawing_Type = 851 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\851

The express.txt File

Appendix A

65

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
Orthographic_Drawings_by_Drawing_Type: ! Lighting Perspectives, Plans, Sections and Details Drawing_Type = 865 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\865 Orthographic_Drawings_by_Drawing_Type: ! HVAC Perspectives, Plans, Sections and Details Drawing_Type = 971 Default_Node = file_server_node Default_Path = pds_dwg_data:\pds\dwg\971 Drawing_Borders: ! PDS Drawing Borders will be copied into specified location for new users only Node = file_server_node Path = pds_dwg_data:\pds\dwg\border Piping_Eden_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\eden_piping Dimension_or_Spec_Table_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\table Piping_Spec_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\spec Piping_Assembly_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\assembly Standard_Note_Library_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\std_note Equipment_Eden_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\eden_eqp TDF_Table_Source: Default_Node = file_server_node Default_Path = pds_3d_rdb_data:\pds\rdb\source\eqp\tdf Model_Builder_Source: Default_Node = file_server_node Default_Path = pds_model_data:\pds\model_builder Design_Review_Model: Destination_Node = design_review_node Destination_Path = pds_review_data:\pds\design_review Reports: Default_Node = file_server_node Default_Path = pds_report_data:\pds\report\mto Report_Formats: Default_Node = file_server_node Default_Path = pds_report_data:\pds\report\format

66

_ _______________
Appendix A:
Report_Discrimination_Data: Default_Node = file_server_node Default_Path = pds_report_data:\pds\report\discrimination Report_Search_Criteria_Data: Default_Node = file_server_node Default_Path = pds_report_data:\pds\report\search Clash_Reports: Destination_Node = file_server_node Destination_Path = pds_clash_data:\pds\clash\report Clash_Plots: Destination_Node = file_server_node Destination_Path = pds_clash_data:\pds\clash\plot Equipment_IForms: Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp !\ ! Locations of Approved and Unapproved RDB Libraries !/ A_Standard_Note_Library: Source_File = std_note.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = std_note.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Standard_Note_Library: Source_File = std_note.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = std_note.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Label_Description_Library: Source_File = labels.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = labels.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Label_Description_Library: Source_File = labels.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = labels.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Piping_Assembly_Library: Source_File = assembly.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = assembly.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved

The express.txt File

Appendix A

67

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
U_Piping_Assembly_Library: Source_File = assembly.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = assembly.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Graphic_Commodity_Library: Source_File = pip_gcom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = pip_gcom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Graphic_Commodity_Library: Source_File = pip_gcom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\lib Destination_File = pip_gcom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Piping_Spec_Job_Table_Library: Source_File = us_pjstb.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_pjstb.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Piping_Spec_Job_Table_Library: Source_File = us_pjstb.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_pjstb.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_US_Physical_Data_Library: Source_File = us_pcdim.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_US_Physical_Data_Library: Source_File = us_pcdim.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_DIN_Physical_Data_Library: Source_File = din_pcdim.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rddinrdb\piping\libs Destination_File = din_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved

68

_ _______________
Appendix A:
U_DIN_Physical_Data_Library: Source_File = din_pcdim.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rddinrdb\piping\libs Destination_File = din_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_British_Standard_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = bs_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_British_Standard_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = bs_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_European_A_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = eura_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_European_A_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = eura_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_European_B_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = eurb_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_European_B_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = eurb_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_JIS_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = jis_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved

The express.txt File

Appendix A

69

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
U_JIS_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = jis_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Australian_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = aus_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Australian_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = aus_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_International_A_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = inta_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_International_A_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = inta_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_International_B_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = intb_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_International_B_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = intb_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Company_Practice_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = cmp_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved

70

_ _______________
Appendix A:
U_Company_Practice_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = cmp_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Short_Material_Description_Library: Source_File = us_shbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_shbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Short_Material_Description_Library: Source_File = us_shbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_shbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Long_Material_Description_Library: Source_File = us_lgbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_lgbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Long_Material_Description_Library: Source_File = us_lgbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_lgbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Specialty_Material_Description_Library: Source_File = us_spbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_spbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Specialty_Material_Description_Library: Source_File = us_spbom.l Source_Node = software_node Source_Path = pds_product:\win32app\ingr\rdusrdb Destination_File = us_spbom.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Equipment_Graphic_Commodity_Library: Source_File = zi_eqpms.lib Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = zi_eqpms.lib Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\approved

The express.txt File

Appendix A

71

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
U_Equipment_Graphic_Commodity_Library: Source_File = zi_eqpms.lib Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = zi_eqpms.lib Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\unapproved A_Equipment_Tutorial_Definition_Library: Source_File = zi_tutlib.lib Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = zi_tutlib.lib Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\approved U_Equipment_Tutorial_Definition_Library: Source_File = zi_tutlib.lib Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = zi_tutlib.lib Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\unapproved A_Equipment_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = us_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\approved U_Equipment_Physical_Data_Library: Source_File = Source_Node = Source_Path = Destination_File = us_pcdim.l Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\lib\unapproved A_Equipment_Cell_Library: Source_File = equip.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = equip.cel Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\approved U_Equipment_Cell_Library: Source_File = equip.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdeqp\dat Destination_File = equip.cel Destination_Node = file_server_node Destination_Path = pds_3d_rdb_data:\pds\rdb\eqp\unapproved !\ ! Drawing Cell Libraries for each Drawing Type !/

72

_ _______________
Appendix A:
Drawing_Cell_Library_by_Drawing_Type: ! Foundation Location Drawings Drawing_Type = 535 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_535.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Piling Drawings Drawing_Type = 537 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_537.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Structural Perspectives, Plans, Sections and Details Drawing_Type = 540 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_540.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Plot Plans Drawing_Type = 641 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_641.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Equipment Arrangement Drawings Drawing_Type = 643 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_643.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Piping Underground Drawings Drawing_Type = 651 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_651.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell

The express.txt File

Appendix A

73

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
Drawing_Cell_Library_by_Drawing_Type: ! Equipment Orientations Drawing_Type = 661 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_661.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Piping One Line Drawings Drawing_Type = 663 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_663.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Piping Perspectives, Plans, Sections and Details Drawing_Type = 665 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_665.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Pipeline Alignment Drawings Drawing_Type = 667 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_667.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Instrument Location Plans Drawing_Type = 731 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_731.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Electrical Area Classification Drawings Drawing_Type = 841 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_841.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell

74

_ _______________
Appendix A:
Drawing_Cell_Library_by_Drawing_Type: ! Electrical Underground Drawings Drawing_Type = 851 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_851.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! Lighting Perspectives, Plans, Sections and Details Drawing_Type = 865 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_865.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell Drawing_Cell_Library_by_Drawing_Type: ! HVAC Perspectives, Plans, Sections and Details Drawing_Type = 971 Source_File = drawing.cel Source_Node = software_node Source_Path = pds_product:\win32app\ingr\pdshell\cell Destination_File = dwg_971.cel Destination_Node = file_server_node Destination_Path = pds_dwg_data:\pds\dwg\cell !\ ! Reference Data Locations for All 2D Disciplines !/ PDS2D_Reference_Data: Node = file_server_node Path = pds_2d_rdb_data:\pds\pds2d\rdb PID_Reference_Data: Node = file_server_node Path = pds_2d_rdb_data:\pds\pid\rdb PFD_Reference_Data: Node = file_server_node Path = pds_2d_rdb_data:\pds\pfd\rdb !\ ! Miscellaneous !/ Copy_Report_Format_and_Search_Criteria_Data: Source_Project_No = Material_Reference_Database: Source_Project_No = Raceway_Reference_Database: Source_Project_No = ! ! Notes: !

The express.txt File

Appendix A

75

_ _______________
PDS Express Project Creation Quick Start Guide April 2002
! 1) The value for each drawing type, Drawing_Type = xxx, should be extracted ! from CL2000 in the Standard Note Library. !

76

_ _______________
Appendix B:

Sample Data

Appendix B Sample Data


Four sample projects are available with the New User option. These projects are set up as follows: Product Loaded RD_USRDB RD_USRDB RD_USRDB RD_DINDB NPD Units English English Metric Metric Model Units English Metric Metric Metric Sample Project English Mixed Metric DIN

Appendix B

Each of these projects contain models from the following disciplines: Piping, Equipment, Structural (FrameWorks), and Raceway. These projects also include drawing. The dataset that is loaded is determined based on the following criteria: If you choose English NPD units and English model units, the English project is loaded. If you choose English NPD units and Metric model units, the Mixed project is loaded. If you choose Metric NPD units and Metric model units, the Metric project is used unless you have the RD_DINRDB product installed on your system. In that case, the DIN project is loaded.

Information in the Delivered Dataset


Each dataset contains a file named sample_data.txt, which identifies the files to be loaded for that dataset. English Piping models: pipealm1, pipealm2, and pipealm3; Equipment model: eqpalm1; Raceway model: rwayalm1; Structural subproject: fw1; Orthographic drawings: aircool, htexchg, pumps, tank, overall001, overall002, piping001, pipin002, cable. Mixed Piping models: pipealm1, pipealm2, pipealm3; Equipment model: eqpalm1; Raceway model: rwayalm1; Structural subproject: sametric; Orthographic drawing: EXAMPLE. Metric Piping models: pipealm1, pipealm2, pipealm3; Equipment model: eqpa1; Raceway model: rway1a1; Structural subproject: sametric; Orthographic drawing: EXAMPLE. DIN Piping models: pipmod1, pipmod2, pipmod3, pipmod4; Equipment models: eqpmod1, eqpmod2; Structural subproject: frm1; Orthographic drawings: fundament, produktion, tanklager, rohr_prod1, rohr_prod2, rohr_tank.

77

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 No example specs are loaded for any of the sample projects. You must load specs in the specification /material reference database before you can work in the new project.

P&ID Assemblies
In addition to the sample datasets, P&ID assemblies are also delivered to enable you to create P&IDs that correspond to the sample projects. English/Mixed project 38pi1.asm, 39pi1.asm, 40pi1.asm, 40pi1.asm, 40pi2.asm, and 41pi1.asm. Metric project 39m1.asm, 39m1.asm, 40m1.asm, and 41m1.asm. DIN project prod01.asm, and tank01.asm. The system does not automatically load the assemblies into the created project. You should create the necessary units and drawings (one drawing for each assembly) in the PDS2D environment. Then use the Place Assembly command within the P&ID environment to place the graphics for the P&IDs. You can propagate the created drawings to load the information into the P&ID database.

78

_ _______________
Appendix C:

Delivered SQL Scripts

Appendix C Delivered SQL Scripts


The following SQL scripts are delivered with the PD_Shell product in the win32app\ingr\pdshell\sql\ directory. You can use these scripts to simplify the process of creating the required database information before creating a new PDS project or to drop information from the database after deleting a PDS project. These scripts have been provided as examples and should not be used until a database manager at your site has reviewed them to ensure that they will be usable in a specific database environment. Intergraph Corporation assumes no risks or responsibilities regarding the use of these files. They are provided for use at your discretion. These scripts require that the database engine has already been installed and configured to support the creation of new databases/users. Use a text editor to review the comments at the top of each file for information to be edited and information on how to run the scripts. \pdshell\sql\mssql\create.sql Script to create all MS SQL Databases for a PDS project.

Appendix C

\pdshell\sql\mssql\drop.sql Script to drop all MS SQL databases for a PDS project. \pdshell\sql\oracle\create.sql Script to create all Oracle users for a PDS project. \pdshell\sql\oracle\drop.sql Script to drop all Oracle users for a PDS project. \pdshell\sql\sybsql\create.sql Script to create all Sybase SQL databases for a PDS project. \pdshell\sql\sybsql\drop.sql Script to drop all Sybase SQL databases for a PDS project.

79

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

80

_ _______________
Index
2D reference data 58 A A_Australian_Physical_Data_Library keyword 57 A_British_Standard_Physical_Data_Library keyword 56 A_Company_Practice_Physical_Data_Library keyword 57 additional resources related documents 7 A_DIN_Physical_Data_Library keyword 56 Advanced User mode 16, 27 how to use 27 A_Equipment_Cell_Library keyword 58 A_Equipment_Graphic_Commodity_Library keyword 58 A_Equipment_Physical_Data_Library keyword 58 A_Equipment_Tutorial_Definition_Library keyword 58 A_European_A_Physical_Data_Library keyword 56 A_European_B_Physical_Data_Library keyword 56 A_Graphic_Commodity_Library keyword 56 A_International_A_Physical_Data_Library keyword 57 A_International_B_Physical_Data_Library keyword 57 A_JIS_Physical_Data_Library keyword 56 A_Label_Description_Library keyword 55 A_Long_Material_Description_Library keyword 57 Alternate_Seed_Drawing keyword 52 A_Piping_Assembly_Library keyword 55 A_Piping_Spec_Job_Table_Library keyword 56 Architectural_Models keyword 54 A_Short_Material_Description_Library keyword 57 A_Specialty_Material_Description_Library keyword 57 A_Standard_Note_Library keyword 55 attributes 35 case sensitive 37 displaying 36 modifying 35 Attributes to be Case Insensitive option 37 Attributes to be Displayed option 36 A_US_Physical_Data_Library keyword 56 B borderifc.dgn file 53 C case sensitive attributes 37 cell libraries 58 Clash_Plot_Border keyword 53 clash_plot.cel file 53 Clash_Plot_Cell_Library keyword 53 Clash_Plots keyword 55 Clash_Plot_Settings keyword 53 Clash_Reports keyword 55 contents of document 7 Copy Delivered RDB Data to New Project option 44 Copy Existing RDB to New Project option 42, 44 Copy Files to Project Directory form 47 Copy RDB Data option 43 Create Database Schemas form 21, 32 Create FrameWorks Sub-Project form 25, 50 Create Project Control Schema form 22, 32 customization 51 customized projects 27 D Database Customization Options form 34 Database Management System Location field 24, 33 Database Name field 23, 33 Database Structure Revision form 34 Database Username field 23, 33 DBAccess 39 DBTEMP field 24, 34 default directory structure 17 default file locations 54 Default_Seed_Drawing keyword 52 Define Default Miscellaneous File Locations form 48 Define Location for New RDB option 42, 44 Define Project Data form 19, 28 Define RDB File Locations form 40 Define System Units form 20, 29 Design_Review_Model keyword 55 Dimension_or_Spec_Table_Source keyword 54 directory structure default 17 document organization 7

Index

Index

81

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 document overview 7 Drawing_Borders keyword 54 Drawing_Category_Descriptions keyword 53 drawing.cel file 52 Drawing_Cell_Library keyword 52 Drawing_Cell_Library_by_Drawing_Type keyword 58 Drawing_Labels_per_Object_Type keyword 52 drawplotsize file 52 drwcats.txt file 53 DSQUERY field 24, 34 E ee.cfg file 53 eqp_center.dwg file 53 eqp_object.dwg file 52 Equipment_Centerline_Definitions_for_Drawings keyword 53 Equipment_Eden_Source keyword 55 Equipment_IForms keyword 55 Equipment_Models keyword 54 Equipment_Objects_for_Drawing_Annotation keyword 52 Equipment_Seed_Model keyword 52 express.txt file 18, 51 2D reference data 58 cell libraries 58 default file locations 54 RDB libraries 55 seed files 52 syntax 51 F files 2D reference data 58 borderifc.dgn 53 cell libraries 58 clash_plot.cel 53 default locations 54 drawing.cel 52 drawplotsize 52 drwcats.txt 53 ee.cfg 53 eqp_center.dwg 53 eqp_object.dwg 52 express.txt 18, 51 framewks.txt 53 ifc.i 53 in_object.dwg 52 lab_button.dwg 53 pid_npd_equiv 53 files (continued) pid_to_piping 53 pipecats2.txt 53 pipecats.txt 53 queue_descript 53 RDB libraries 55 RDB_options 53 spec_order.max 54 stnote_max_len 54 symbology.sms 53 forms Copy Files to Project Directory 47 Create Database Schemas 21, 32 Create FrameWorks Sub-Project 25, 50 Create Project Control Schema 22, 32 Database Customization Options 34 Database Structure Revision 34 Define Default Miscellaneous File Locations 48 Define Project Data 19, 28 Define RDB File Locations 40 Define System Units 20, 29 Revise Working Units 31 Server Names & Drive Letters 24 framewks.txt file 53 FrameWorks_Category_Descriptions keyword 53 H HVAC_Models keyword 54 I ifc.i file 53 in_object.dwg file 52 Instrument_Objects_for_Drawing_Annotation keyword 52 introduction 13 K keyword Label_Button_for_Drawing_Annotation 53 keywords A_Australian_Physical_Data_Library 57 A_British_Standard_Physical_Data_Library 56 A_Company_Practice_Physical_Data_Library 57 A_DIN_Physical_Data_Library 56 A_Equipment_Cell_Library 58 A_Equipment_Graphic_Commodity_Library 58 A_Equipment_Physical_Data_Library 58 A_Equipment_Tutorial_Definition_Library 58 A_European_A_Physical_Data_Library 56 A_European_B_Physical_Data_Library 56 A_Graphic_Commodity_Library 56

82

_ _______________

Index

keywords (continued) keywords (continued) A_International_A_Physical_Data_Library 57 Piping_Model_Category_Descriptions_by_NPD A_International_B_Physical_Data_Library 57 53 A_JIS_Physical_Data_Library 56 Piping_Models 54 A_Label_Description_Library 55 Piping_Seed_Model 52 A_Long_Material_Description_Library 57 Piping_Spec_Source 54 Alternate_Seed_Drawing 52 Queue_Description_Library 53 A_Piping_Assembly_Library 55 Raceway_Configuration_File 53 A_Piping_Spec_Job_Table_Library 56 Raceway_Project_Directory 54 Architectural_Models 54 Raceway_Seed_Model 52 A_Short_Material_Description_Library 57 RDB_Option_File 53 A_Specialty_Material_Description_Library 57 Report_Discrimination_Data 55 A_Standard_Note_Library 55 Report_Formats 55 A_US_Physical_Data_Library 56 Reports 55 Clash_Plot_Border 53 Report_Search_Criteria_Data 55 Clash_Plot_Cell_Library 53 Spec_Order_Maximum_Length_Table 54 Clash_Plots 55 Standard_Note_Library_Source 54 Clash_Plot_Settings 53 Standard_Note_Maximum_Length_Table 54 Clash_Reports 55 TDF_Table_Source 55 Default_Seed_Drawing 52 U_Australian_Physical_Data_Library 57 Design_Review_Model 55 U_British_Standard_Physical_Data_Library 56 Dimension_or_Spec_Table_Source 54 U_Company_Practice_Physical_Data_Library 57 Drawing_Borders 54 U_DIN_Physical_Data_Library 56 Drawing_Category_Descriptions 53 U_Equipment_Cell_Library 58 Drawing_Cell_Library 52 U_Equipment_Graphic_Commodity_Library 58 Drawing_Cell_Library_by_Drawing_Type 58 U_Equipment_Physical_Data_Library 58 Drawing_Labels_per_Object_Type 52 U_Equipment_Tutorial_Definition_Library 58 Equipment_Centerline_Definitions_for_Drawings U_European_A_Physical_Data_Library 56 53 U_European_B_Physical_Data_Library 56 Equipment_Eden_Source 55 U_Graphic_Commodity_Library 56 Equipment_IForms 55 U_International_A_Physical_Data_Library 57 Equipment_Models 54 U_International_B_Physical_Data_Library 57 Equipment_Objects_for_Drawing_Annotation 52 U_JIS_Physical_Data_Library 57 Equipment_Seed_Model 52 U_Label_Description_Library 55 FrameWorks_Category_Descriptions 53 U_Long_Material_Description_Library 57 HVAC_Models 54 U_Piping_Assembly_Library 56 Instrument_Objects_for_Drawing_Annotation 52 U_Piping_Spec_Job_Table_Library 56 Model_Builder_Source 55 U_Short_Material_Description_Library 57 ModelDraft_Category_Descriptions 53 U_Specialty_Material_Description_Library 57 Orthographic_Drawing_Plot_Size_Table 52 U_Standard_Note_Library 55 Orthographic_Drawings_by_Drawing_Type 54 U_US_Physical_Data_Library 56 PDS2D_Reference_Data 58 PDS_Project_Directory 54 L PFD_Reference_Data 58 lab_button.dwg file 53 PID_Reference_Data 58 Label_Button_for_Drawing_Annotation keyword 53 PID_to_Piping_Correlation_Table 53 PID_to_Piping_NPD_Equivalent_Table 53 M Piping_Assembly_Source 54 Model_Builder_Source keyword 55 Piping_Eden_Source 54 ModelDraft_Category_Descriptions keyword 53 Piping_Model_Category_Descriptions_by_Fluid_Code modifying attributes 35 53

Index

83

_ _______________
PDS Express Project Creation Quick Start Guide April 2002 N Network Protocol field 23, 33 New User mode 15, 17 how to use 18 Node Name or Address field 23, 33 O Orthographic_Drawing_Plot_Size_Table keyword 52 Orthographic_Drawings_by_Drawing_Type keyword 54 OS Type field 23, 33 OS Username field 23, 33 overview 7 project setup 13 P Password field 23, 33 PDS2D_Reference_Data keyword 58 PDS_Project_Directory keyword 54 PFD_Reference_Data keyword 58 pid_npd_equiv file 53 PID_Reference_Data keyword 58 pid_to_piping file 53 PID_to_Piping_Correlation_Table keyword 53 PID_to_Piping_NPD_Equivalent_Table keyword 53 pipecats1.txt file 53 pipecats2.txt file 53 Piping_Assembly_Source keyword 54 Piping_Eden_Source keyword 54 Piping_Model_Category_Descriptions_by_Fluid_Code keyword 53 Piping_Model_Category_Descriptions_by_NPD keyword 53 Piping_Models keyword 54 Piping_Seed_Model keyword 52 Piping_Spec_Source keyword 54 plant monument entering coordinates 21 plant monument coordinates 30 preface 7 prerequisites 14 project schemas 32 project setup overview 13 project setup steps 13 Q queue_descript file 53 Queue_Description_Library keyword 53 R Raceway_Configuration_File keyword 53 Raceway_Project_Directory keyword 54 Raceway_Seed_Model keyword 52 RDB libraries 55 RDB_Option_File keyword 53 RDB_options file 53 related documents 7 Report_Discrimination_Data keyword 55 Report_Formats keyword 55 reporting options 39 Reports keyword 55 Report_Search_Criteria_Data keyword 55 Revise Working Units form 31 S schemas 32 seed files 52 Server Names & Drive Letters form 24 Share RDB with Existing Project option 42, 44 spec_order.max file 54 Spec_Order_Maximum_Length_Table keyword 54 SQLEXEC field 24, 33 Standard_Note_Library_Source keyword 54 Standard_Note_Maximum_Length_Table keyword 54 starting the program 14 stnote_max_len file 54 SYBIFILE field 24, 34 symbology.sms file 53 T TBCONFIG field 24, 34 TDF_Table_Source keyword 55 typefaces 9 U U_Australian_Physical_Data_Library keyword 57 U_British_Standard_Physical_Data_Library keyword 56 U_Company_Practice_Physical_Data_Library keyword 57 U_DIN_Physical_Data_Library keyword 56 U_Equipment_Cell_Library keyword 58 U_Equipment_Graphic_Commodity_Library keyword 58 U_Equipment_Physical_Data_Library keyword 58 U_Equipment_Tutorial_Definition_Library keyword 58 U_European_A_Physical_Data_Library keyword 56

84

_ _______________
U_European_B_Physical_Data_Library keyword 56 U_Graphic_Commodity_Library keyword 56 U_International_A_Physical_Data_Library keyword 57 U_International_B_Physical_Data_Library keyword 57 U_JIS_Physical_Data_Library keyword 57 U_Label_Description_Library keyword 55 U_Long_Material_Description_Library keyword 57 U_Piping_Assembly_Library keyword 56 U_Piping_Spec_Job_Table_Library keyword 56 User Defined Attributes option 36 U_Short_Material_Description_Library keyword 57 using Advanced User mode 27 using the New User option 18 U_Specialty_Material_Description_Library keyword 57 U_Standard_Note_Library keyword 55 U_US_Physical_Data_Library keyword 56 W working units 30

Index

Index

85

_ _______________
PDS Express Project Creation Quick Start Guide April 2002

86

S-ar putea să vă placă și