Optional IP65 ABS Enclosure 120 x 120 x 100
The current product lines are now to be found in a range of devices in the standard Eliwell 32x74 size and incorporate in one single controller all the best technological and application solutions that have distinguished our electronic controllers for years along with 72x72 panel mount and DIN rail mount models.
DR4020
32 X 74 PANEL MOUNT SINGLE LINE DISPLAY IC902 NTC/PTC Single Stage Temperature Controller 0.1 degree steps 3 digit with and without decimal point IC915,915LX Pt100 / TcJ / TcK NTC/PTC Two Stage Temperature Controller DTN121210H DIN RAIL MOUNT DR4020 DR4022 DATA LOGGER MEMORY 1000 METERING AVAM TRANSFORMER TF111117 240V/12V 15VA Power Supply for 12V Controllers IP65 ABS Enclosure 120 x 120 x 100
GRIMWOOD HEATING PTY LTD ABN 40 105 569 739 Mailing Address: P.O. Box 4 Villawood NSW 2163 Phone: 02 8717 0222 Fax: 02 8717 0284 www.grimwoodheating.com.au sales@grimwoodheating.com.au
SECTION
15-9
PAGE 15-9-2
81007 81008
81011 81012
Ideal for laboratories and industrial applications when a permanently hard-wired installation is not required. The units can be user adjusted for set point, differential and heating or cooling. 81007
NOTE: The maximum load rating is for pure resistance loads, such as a heating element. Where a motor, such as a pump or fan is used, the starting current of the motor should not exceed the maximum stated.
GRIMWOOD HEATING PTY LTD ABN 40 105 569 739 Mailing Address: P.O. Box 4 Villawood NSW 2163 Phone: 02 8717 0222 Fax: 02 8717 0284 www.grimwoodheating.com.au sales@grimwoodheating.com.au
EW7220 - EW7222
C3
Applications The new Eliwell thermoregulators in the Universal Controller series are ideal for all industrial applications requiring high precision temperature control, ranging from the moulding of plastic materials and packaging to raw material transformation process control. Common features Front panel: IP65 Container: PC+ABS UL94 V-0 resin plastic casing, switch keys with adhesive polycarbonate film Dimensions: front panel 72x72mm, depth 80mm
General features Display: Analogue inputs: Digital inputs: Connections:
Installation: panel mounting with 67x67mm drilling template (+0.2/-0.1mm) Operating temperature: -5...55C Storage temperature: -20...85C Ambient humidity for operation and storage: 10...90% RH (non-condensing)
EW7222 no decimal point * 2 4-digit displays + sign 1 input*(see Analogue Inputs table) 1 clean contact at extra low safety voltage TTL port and internal RS-485 for connection to Copy Card, TelevisSystem or systems with ModBus protocol 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250V~ 1 SPST 5A 250Va V-I: 0...1V, 0...5V, 0...10V / 0...20mA, 4...20mA according to probe used according to probe used according to probe used 3W max 12...24Va/12...36Vc 10% 50/60Hz 100...240Va 10% 50/60Hz
EW7220 no decimal point * 2 4-digit displays + sign 1 input*(see Analogue Inputs table) not available TTL port for connection to Copy Card, TelevisSystem or systems with ModBus protocol 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250Va not available according to probe used according to probe used according to probe used 3W max 12...24Va/12...36Vc 10% 50/60Hz 100...240Va 10% 50/60Hz
Digital outputs:
Analogue output: Measurement range: Accuracy: Resolution: Power consumption: Power supply:
*(selectable by parameter)
Wiring diagrams
Sonde
10 11 12 PTC/NTC/Pt1000 10 11 12 Pt100 + 10 11 12 TC 10 11 12 + +12V
EW7220
EW7222
14 15 17 18 19 20 21 22 23 24
D.I. out3
+ +
GND
RS-485
V (0...1/0...5/0...10V) I (0...20/4...20mA)
out 1
out 2
out 1
out 2
1 2 3 4 5
8 9 10 11 12
Power Supply Sonde
V-I
1 2 3 4 5
8 9 10 11 12
Power Supply Sonde
1 2 3 4 5 6 7
10 11 12
1 2 3 4 5 6 7
10 11 12
C4
DR4020 - DR4022
Applications The new Eliwell thermoregulators in the Universal Controller series are ideal for all industrial applications requiring high precision temperature control, ranging from the moulding of plastic materials and packaging to raw material transformation process control. Common features Front panel: IP65 Container: plastic casing with 4 DIN modules Dimensions: front panel 70x85mm, depth 61mm Installation: on DIN rail (Omega 3) or panel mounting, with 70x45mm (+0.2/-0.1mm) drilling template
General features Display: Analogue inputs: Digital inputs: Connections:
Operating temperature: -5...55C Storage temperature: -20...85C Ambient humidity for operation and storage: 10...90% RH (non-condensing)
DR4022 no decimal point * 2 4-digit displays + sign 1 input* (see Probes table) 1 clean contact at extra low safety voltage TTL port and internal RS-485 for connection to Copy Card, TelevisSystem and systems with ModBus protocol 1 SPDT 3A 250Va + 1 SPST 2A 250Va V-I: 0...1V, 0...5V, 0...10V / 0...20mA, 4...20mA according to probe used according to probe used according to probe used 4W max 12...24Va/12...36Vc 10% 50/60Hz 100...240Va 10% 50/60Hz
DR4020 no decimal point * 2 4-digit displays + sign 1 input* (see Probes table) not available TTL port for connection to Copy Card, TelevisSystem and systems with ModBus protocol 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250Va not available according to probe used according to probe used according to probe used 4W max 12...24Va/12...36Vc 10% 50/60Hz 100...240Va 10% 50/60Hz
Digital outputs: Analogue output: Measurement range: Accuracy: Resolution: Power consumption: Power supply:
*(selectable by parameter)
Wiring diagram
1 2
1 2
5 6 7 8 9 10 11 12
D.I.
+ +
Sonde
222324
+ -
222324
222324
PTC/Pt1000
GND
out2
out2
RS-485
DR4020
out 1 100...240Va
TTL out 1
DR4022
TTL 100...240Va
Pt100
NTC
222324
100...240Va 12...24Va 12...36Vc
+ -
21 22 2324
+12V
13 14 15
out 1
19 20 21 22 23 24
12...24Va 12...36Vc
13 14 15
out 1
19 20 21 22 23 24
12...24Va 12...36Vc
TC
+ V + I -
22 2324
+VV (0...5/0...10Vc)
13 14 15
18 19
21 22 23 24
13 14 15
18 19
21 22 23 24
I (0...20/4...20mA) V (0...1Vc)
C6
IC902
Applications IC902 controllers are one-step devices which can be used for both heating and cooling applications.
Common features Front panel: IP65 Container: PC+ABS UL94 V-0 plastic resin casing, polycarbonate window, thermoplastic resin keys Dimensions: front panel 74x32mm, depth 59mm
General features Display range: Display: Analogue inputs: Connections: Digital outputs: Measurement range: Accuracy: Resolution: Power consumption: Power supply: Alarm:
*(selectable by parameter)
Installation: panel mounting with 71x29 mm (+0.2/0.1 mm) drilling template Operating temperature: -5...55C Storage temperature: -30...85C Ambient humidity for operation and storage: 10...90% RH (non-condensing)
IC902/A NTC probe: -50.0...110.0C PTC probe: -55.0...140.0C no decimal point * 3 and a half digits + sign 1 PTC or NTC * TTL port for connection to Copy Card 1 SPDT 8(3)A 250Va from -50 to 99C better than 0.5% of end of scale +1 digit 0.1 or 1C 1.5W for model 12Va 3W for model 230Va 12Va 10% 50/60Hz 230Va 10% 50/60Hz present
IC902 NTC probe: -50.0...110.0C PTC probe: -55.0...140.0C no decimal point * 3 and a half digits + sign 1 PTC or NTC * TTL port for connection to Copy Card 1 SPDT 8(3)A 250Va from -50 to 140C better than 0.5% of end of scale +1 digit 0.1 or 1C 1.5W for model 12Va 3W for model 230Va 12Va, 12/24Va/C 10% 50/60Hz 230Va 10% 50/60Hz not available
Wiring diagram
IC 902
out1 230Va Pb1
IC 902 /A
Pb1 230Va
1 2 3 6 7
out1 12Va
8 9
Pb1
230Va
1 2 3 6 7
12Va
8 9
Pb1
230Va
1 2 3
6 7 8 9
12Va
1 2 3
6 7 8 9
12Va
Codes p/n description Relay Probe Power supply IC11C00TCD700 IC902 Cooling 8A PTC 230V IC11C00THD700 IC902 Heating 8A PTC 230V
Codes p/n description Relay Probe Power supply IC11C00TCD400 IC902 Cooling 8A PTC 12/24Va/C
IC915
C9
Applications IC915 controllers are electronic two-step devices, either dependent or independent or with neutral zone, used to control temperature, relative humidity and pressure. Common features Front panel: IP65 Container: PC+ABS UL94 V-0 plastic resin casing, polycarbonate window, thermoplastic resin keys Dimensions: front panel 74x32mm, depth 59mm Installation: panel mounting with 71x29mm drilling template
General features Display range: IC915 NTC/PTC NTC probe: -50.0...110.0C PTC probe: -55.0...140.0C no decimal point * 3 and a half digits + sign 1 PTC or NTC * TTL port for connection to Copy Card 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250Va from -50 to 140 better than 0.5% of end of scale +1 digit
(+0.2/-0.1mm) Operating temperature: -5...55C Storage temperature: -30...85C Ambient humidity for operation and storage: 10...90% RH (non-condensing) Soft Start function present
IC915 LX TC/Pt100 Pt100 probe: -150...650C TcJ probe: -40...750C TcK probe: -40...1350C no decimal point * 3 and a half digits + sign 1 Pt100 or 1 TcJ/TcK TTL port for connection to Copy Card 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250Va from -150 to 1350 Pt100: 0.5% for whole scale + 1 digit, 0.2% from -150 to 300C TcJ: 0.4% for whole scale + 1 digit TcK: 0.5% for whole scale + 1 digit, 0.3% from -40 to 800C Pt100: 0.1C (0.1F) up to 199.9C 1C (1F) over TcJ: 0.1C (0.1F) up to 199.9C (1F) over TcK: 0.1C (0.1F) 1.5W for model 12Va 3W for model 230Va 12Va/12..24Va/24Va 10% 50/60Hz 110...115Va/220...230Va10% 50/60Hz optional
IC915 LX P/R/V-I -99...100 * -99.9...100.0 * 999...1000 * no decimal point * 3 and a half digits + sign
1 V-I (0...1V,0...5V,0...10V,0...20mA,4...20mA)*
TTL port for connection to Copy Card 1 SPDT 8(3)A 250Va + 1 SPST 8(3)A 250Va from -999 to 1000 better than 0.5% of end of scale +1 digit
Resolution:
0.1 C
0.1 or 1C *
1.5W for model 12Va 3W for model 230Va 12Va/12..24Va/24Va 10% 50/60Hz 110...115Va/220...230Va10% 50/60Hz optional
1.5W for model 12Va 3W for model 230Va 12Va/12..24Va/24Va 10% 50/60Hz 110...115Va/220...230Va10% 50/60Hz optional
Wiring diagram
IC 915 NTC-PTC
out1 out2 230Va
Pb1
IC 915 P-R-V/I
230Va
IC 915 Pt100/TC
V
1 2 3 4 5 6 7
out1 out2 12Va
8 9 10
Pb1
230Va
1 2 3 4 5 6 7
out1 out2 12Va
8 9 10 11
V
1 2 3 4 5
6 7 8 9 10
12Va
1 2 3 4 5
6 7 8 9 10 11
description Probe Power supply IC915 temperature NTC/PTC 230Va IC915 temperature NTC/PTC 12...24Va IC915 temperature TC/Pt100 230Va IC915 temperature TC/Pt100 12...24Va
Codes p/n description IR12I00TBD700 IC915 humidity IP12A00TRD700 IC915 pressure IP12B00TRD700 IC915 pressure IC12I00TRN700 IC915 neutral
+ +
out1
out2
Pb1 +12V
out1
out2 230Va
230Va
1 2 4 5 6 7
out1 out2 12Va
10 11 12
230Va
Pb1 +12V
+
6 7
12Va
1 2 4 5
10 11 12
12Va
Probe Power supply 4...20mA 230Va EWPA 007 230Va EWPA 030 230Va 4...20mA 230Va
C12
EWTS950 LX - EWTS990 LX
Applications The Eliwell series of digital timers is the ideal measuring solution for all measurable quantities in commercial refrigeration and light industry. The range, which consists of 2 different models, is used in all applications requiring precision control of processing stages and the management of functions linked to preset time intervals. Common features Front panel: IP65 Container: PC+ABS UL94 V-0 plastic resin casing, polycarbonate window, thermoplastic resin keys Dimensions: front panel 74x32mm, depth 59mm
General features Display range: Display: Digital inputs: Connections: Digital outputs: Accuracy: Power consumption: Power supply: External battery: EWTS950 LX
Installation: panel mounting with 71x29 mm (+0.2/0.1 mm) drilling template Operating temperature: -5...55C Storage temperature: -30...85C Ambient humidity for operation and storage: 1090% RH (non-condensing)
EWTS990 LX
9999 hours / 99 hours and 59 minutes / 99 minutes and 59 seconds 9999 hours / 99 hours and 59 minutes / 99 minutes and 59 seconds
/ 99 seconds and 99 hundredths of a second / 99 seconds and 99 hundredths of a second no decimal point * 4 digits + sign no decimal point * 4 digits + sign 2 clean contacts at extra low safety voltage 2 clean contacts at extra low safety voltage TTL port for connection to Copy Card and TelevisSystem TTL port for connection to Copy Card and TelevisSystem 1 SPDT 8(3)A 1/2hp 250Va 1 SPDT 8(3)A 1/2hp 250Va + 3.6 sec/h 3VA max 12Va/C oppure 230Va 10% 50/60Hz power supply 9Vc battery duration: depends on model, with 9Vc/10mA/h battery duration 1h instrument absorption with power supply from 10mA battery 1 SPST 8(3)A 1/2hp 250Va 3.6 sec/h 3VA max 12Va/C oppure 230Va 10% 50/60Hz power supply 9Vc battery duration: depends on model, with 9Vc/10mA/h battery duration 1h instrument absorption with power supply from 10mA battery
Wiring diagram
EWTS 950 LX
out1 230Va
DI1 DI2 9Vc V +
EWTS 990 LX
out1 out2 230Va
DI1 DI2 9Vc V +
1 2 3 6 7
out1 12Va
8 9 10 11
DI1 DI2 9Vc V +
230Va
1 2 3 4 5 6 7
out1 out2 12Va
8 9 10 11
DI1 DI2 9Vc V +
230Va
1 2 3
6 7 8 9 10 11
12Va
1 2 3 4 5
6 7 8 9 10 11
12Va
description EWTS950 LX
description EWTS990 LX
E4
Memory1000
Applications Memory1000 is available in a wide range of models, combining the capabilities of a monitoring system with the ease-of-use of a data logger in order to meet various customer requirements. Specifications Powerful, easy to use and cheap to run Compatible with RadioAdapter wireless networks Manages all aspects of network controller alarms
General features User interface: Analogue inputs: Digital inputs: Digital outputs: Connections:
12 months+ data logging capacity A wide range of models to fit all application requirements
Memory1000 with printer Backlit graphic LCD 8 polycarbonate keys Up to 8 analogue inputs (NTC/4...20mA) Up to 2 digital inputs 1 SPDT 5(2)A 250Va RS-485 port for input expansion via compatible Eliwell Televis controllers RS-232 port for exporting data using Microsoft Windows software (supplied) SD memory card slot for downloading data present present 20W max (printer in use) 230Va 10% 50/60Hz Integrated thermal printer
Memory1000 with no printer Backlit graphic LCD 7 polycarbonate keys Up to 8 analogue inputs (NTC/4...20mA) Up to 2 digital inputs 1 SPDT 5(2)A 250Va RS-485 port for input expansion via compatible Eliwell Televis controllers RS-232 port for exporting data using Microsoft Windows software (supplied) SD memory card slot for downloading data present present 5W max 230Va 10% 50/60Hz -
Wiring diagram
9 10 11 12 13
22 23 24
Basic Models
Power Supply
out 1
AI 1
AI 2
AI 3
AI 4
D.I.1 D.I.2
9 10 11 12 13
14 15 16 17 18 19 20 21
22 23 24
1080 1085
AI 1
AI 2
AI 3
AI 4
AI 5
AI 6
AI 7
AI 8
D.I.1 D.I.2
9 10 11 12 13
14 15 16 17 18 19 20 21
22 23 24
AI1
AI2
AI 3
AI 4
AI 5
AI 6
AI 7
AI 8
D.I.1 D.I.2
9 10 11 12 13
14 15 16 17 18 19 20 21
22 23 24
25 26 27
AI1
AI2
AI 3
AI 4
AI 5
AI 6
AI 7
AI 8
D.I.1 D.I.2
- GND RS-485
RS485 models
No Inputs
25 26 27
1100/6
- GND RS-485
Codes
p/n M1K04N03D1X00 M1K08N03D1X00 M1K26S03D1X00 M1K08N03D0X00 description Memory1000 Printer Memory1000 Printer Memory1000 Printer Memory1000 Printer connectable probes 4 NTC 6 NTC+2x4...20mA 6 NTC+2x4...20mA +RS-485 8 NTC
Codes
p/n M1K04X03D0X00 M1K26N03D0X00 M1K26S03D0X00 M1K08N03D0X00 description Memory1000 Memory1000 Memory1000 Memory1000 connectable probes 4 NTC 6 NTC+2x4...20mA 6 NTC+2x4...20mA +RS-485 8 NTC
AVAM
WHAT IT IS AVAM is a digital A.C. instrument field selectable to be used as ammeter or as voltmeter.
HOW IT IS MADE Housing: with plastic ABS, front 72x72 mm Din Depth: 102 mm Mounting: panel mount Connections: terminal block for 4 mm2 leads Relative humidity: from 10% to 90% (no condensing) Voltage range: selectable by front keypad from 0 to 99.9 Vac and from 0 to 600 Vac Current range: selectable by front keypad from 0 to 5 A (direct) and from 0 to 999 A (through A.T. xxx/5) A.T. and decimal point selection: through front keypad Max contact relay: relay 8(2) Amp 250 V Accuracy: 0.5% F.S. 1 digit Resolution: 1/1000 F.S. Consumption: 4 VA max Power supply: 24 Vac 10% or 115/230 Vac 10%, 50/60 Hz
MAIN FEATURES Three digit display (12.5 mm of height) Plastic ABS box 72x72 mm, self-extinguishing Panel mounting Connections through clamp conductor, maximum section 4 mm2 Current input may be direct or through external T.A. with primary of up to 1000 A and 5 A secondary Overload alarm-light One relay output. FRONT KEYPAD SET: to display/modify the setpoint and to have access the programming. UP: value increase key. DOWN: value decrease key. RESET: manual reset key (if enabled). PARAMETERS PROGRAMMING Push the SET key for 5 seconds to enter the programming mode. The PAS label will be shown (the PAS default value is 000). To enter the correct password number use the SET key to shift the next figures, the corresponding led situated on the right low corner of the figure will blink, then push the UP and DOWN arrow keys to modify the figure. Use the UP and DOWN arrow keys to select a parameter label; use the SET key to display / exit the parameter value; use the UP and DOWN arrow keys to modify a parameter value. Wait for 5 seconds without pushing any key to exit the programming.
PARAMETERS DESCRIPTION dP: it select the decimal point. n = whole number; y = decimal point. SEt: SEtpoint value. The range is between 0 and 999. tA: rated T.A. primary value which determines transformation ratio. Programmable from 5 (direct insertion) to 995; "000" corresponds to 1000:5. PAS: PASsword number to access to the parameter programming. The range is between 0 and 999. dI: dIfferential (histeresis). The range is between 1 and 999. od: output delay. The relay will switch after the time set in this parameter; the range is between 5 and 999 tenths of a second. rES: automatic reset. If parameter is set to "n", the output relay is rearmed manually by pressing "Reset" on the front panel. n = no; y = yes. AMMETER FUNCTION Close with a jumper the terminals number 5 and 6. After switching on the power supply, the display shows for 2 seconds the value of the tA parameter and then the input signal on terminals 7 and 8. Push and release the DOWN arrow key to display the amperometric transformer value (tA parameter); it can not be modified. Wait for 5 seconds without pushing any key to exit the amperometric transformer set value.
AVAM
ammeter function
POWER SUPPLY
5 6 7 8 9 10
11 12 13 14 15 16 17 18
Current range: selectable by front keypad from 0 to 5 A (direct) and from 0 to 999 A (through A.T. xxx/5). A.T. and decimal point selection: through front keypad. Max contact relay: relay 8(2) Amp 250 V. Accuracy: 0.5% F.S. 1 digit. Resolution: 1/1000 F.S. Consumption: 4 VA max. Power supply: 24 Vac or 115/230 Vac 10%, 50/60 Hz.
load
Siebe Climate Controls Italia s.p.a. via dellArtigianato, 65 Zona Industriale Paludi 32010 Pieve dAlpago (BL) Italy Telephone +39 0437 986111 Facsimile +39 0437 989066
AC LINE
An Invensys company
AVAM
voltmeter function
POWER SUPPLY
5 6 7 8 9 10
11 12 13 14 15 16 17 18
load
AC LINE
VOLTMETER FUNCTION Keep the terminals number 5 and 6 open. To select the range between 0 and 99.9, enter the programming and set the dp = y; to select the range between 0 and 999, enter the programming and set dp = n. The tA parameter is not available. USER INFORMATION Push and release the SET key to display the setpoint (SEt parameter); the setpoint can not be modified. Wait for 5 seconds without pushing any key to exit the set value. After turning on the power supply the relay output will be energized and the terminal 16 and 18 will be closed. When the input signal is higher then the SEt value, the relay output will be de-energized and the terminals 16 and 18 will be opened.
No manual reset: if the probe signal goes lower than the SEt - dI the system restart automatically. Manual reset: to restart the system push the RESET key. TECHNICAL DATA Housing: with plastic ABS, front 72x72 mm Din. Depth: 102 mm. Mounting: panel mount. Connections: terminal block for 4 mm2 leads. Operating temperature: 565 C; (23149 F). Storage temperature: 3075 C; (22167 F). Relative humidity: from 10% to 90% (no condensing). Voltage range: selectable by front keypad from 0 to 99.9 Vca and from 0 to 600 Vca.