Sunteți pe pagina 1din 20

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE

A guide to the lighting of SURFACE & UNDERGROUND RAILWAY SYSTEMS

Surface Railway Systems Underground Railway Systems

382 388

381

Surface Rail Systems


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
Designplan has worked closely with those involved with railway systems for more than thirty years. Early projects included work at Euston & Kings Cross Stations in London, Glasgow Central in Scotland followed by extensive locomotive sheds in Wolverton. In the early 80s a special fitting was designed, in close co-operation with British Rail engineers, to meet the special needs posed by the introduction of single operator trains. The resulting fitting was our Brunel and following
Grand Central Station New York City Tuscan in pit

its development almost every station on the entire Network S.E. system was converted to include this fitting under canopies in platform areas. Those that were not quite suited to Brunel were provided with new red Sparta instead. Since then we have worked continually with system operators, engineers & contractors both in the UK & overseas designing, manufacturing & supplying high quality, long lasting, value for money solutions to the problems posed by the Railway environment. Indeed the majority of fittings mentioned in this section of the catalogue are available with the

Birmingham New Street Station

Semi Recessed Brunel

Designplan Lifetime Guarantee see page 29. The information that follows will, we believe, assist those working & designing for this, often hostile, environment and will enable the engineer or architect to select a suitable fitting that has often been specifically designed for Railway or similar use. For simplicity we have selected the different areas of Railway infrastructure and then have made suggestions as to which Designplan fitting is best suited to light that given area. There are of course alternatives that appear within our catalogue, should suggestions within this guide not answer a particular need.

Parkalux & Centaur LED

In the event of a special requirement, as is frequently the case with such installations, then we are always pleased to work with the designer to create a Bespoke solution. Recent Bespoke projects include a special linear fitting for canopy areas for stations in the North East of England. Details of this service are provided on page 357.

Station entrance canopies Fittings required can be surface, semi-recessed or fully recessed. The Brunel (p201) & Aztec (p199) are available in all three options. The Tuscan range (p153) most often used in recessed form or if a downlighting solution is sought the RDL (p208) is a weather & vandal resistant answer.

382

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Station exteriors Fittings used to light the outsides of station buildings need to be both weather resistant and importantly, because of their locations in villages & towns, very strong. The following list has been selected with both of these criteria in mind but also, in a number of cases, with aesthetic appearance playing an important role.
Quay (p232) Flat area

The list provided is extensive & reflects the wide range of fittings we manufacture that have the selected features mentioned above. Pantheon (p205), Capella (p260), Ali Quadgrille (p190/191), Quadgrille (p194/195), Quay (p232), Maxi Callisto (p256), Vertigo (p252/255), Ziggy (p261), Cloister (p250), Wall Mount Brunel (p204), Corner Brunel (p202), Corner Quadrangle (p196), Hood (p245), Brunangle (p200) & Quadrato (p183). Car Parks flat Post top fittings that are weather & vandal resistant. Solaris (p267), Concourse (p271), Hermes (p274) & Post Top Brunel (p273). Car Parks multi story Linear fluorescent, bulkhead compact fluorescent & discharge fittings that are weather & vandal resistant. Parkalux (p148/149), Monitior (p150/151), Sparta (p146/147), Quadrant (p192), Quadring (p222) & Deluxe Brunel (p201). Under Bridge or Tracks Either a standard from the Tuscan range (p153) or a special Tuscan made to suit the project as that shown in the picture above right, for Dutch Railways, also suitable our Pantheon (p205), Circular Brunel (p238). Some projects require a continuous mounting system with in-built cable management trunking. If required please contact our technical sales o ffice 020.8254.2022.
Multi story car park Under bridge, Dutch Railways

383

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Underpass/Subway Usually an angled or recessed Tuscan (p153), Rampart (p166), Metro (p144),Tuscan II (p159), Mission (p145) & RDL (p208). Covered Walkway Recessed Tuscan (p153), Bergen (p167), Camasys (p162), Metro (p144), Mission (p145), Parkalux (p148/149), Monitor (p150/151), Aztec (p199), Deluxe Brunel (p201), Bubble (p226), Spoke (p230) & RDL (p208) Concourse Area Ceiling Flair (p143), RDL (p208), Antares (p351), Metro (p144), Corvo (p89), Sable (p62), Mink (p63), Recessed Tuscan (p153), Mission (p145), Camasys (p162) & Parkalux (p148/149).
St. Denis Station, Stade de France, Paris using Metro, page 144.

Wall Cloister (p250), Quay (p232), Mission (p145), Maxi Callisto (p256), Ali Quadgrille (p190/191), Quadgrille (p194/195), Vertigo (p252/255), Pantheon (p205) & Capella (p260). In-ground Centaur L.E.D. (p110), Scoop L.E.D. (p108), Centaur (p300)_& Parador L.E.D. (p119). Ticket Hall Camasys (p162), Flair (p143), Mission (p145), RDL (p208), Antares (p351), Sable (p62), Mink (p63), Recessed Tuscan (p153), & Parkalux (p148/149). Escalators Ceiling RDL (p208), Antares (p351), Camasys (p162), Flair (p143), Mission (p145), Metro (p144), Sable (p62), Mink (p63), Recessed Tuscan (p153), & Parkalux

Grand Central Station, New York City

(p148/149). Wall Bubble (p226), Torino (p55), Maxi Callisto (p256), Ali Quadgrille (p190/191) & Buccaneer (p179-218). Escalator side wall Centaur (p300 & 110), Topaz (p128), Brick Light (p173), Bastion (p170), RDL (p208) & Zenith (p114).

384

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Stairways Ceiling RDL (p208), SDL (p217), Aztec (p199), Antares (p351), Sable (p62), Mink (p63), Corvo (p89), Recessed Tuscan (p153), Metro (p144), & Parkalux (p148/149). Wall Torino (p55), Angle Tuscan (p156), Tuscan II (p159), Quadrato (p183), Ali Quadgrille (p190/191), Quadgrille (p194/195), Vertigo (p252/255), Brunangle (p200) & Circo (p220). Toilets Buccaneer (p179 & 218), Torino (p55), Camino (p76), Kalico (p77), RDL (p208), Circo (p220), Quadrant (p192), Quadring (p222), Aztec (p199), Antares (p351), Recessed Tuscan (p153), Parkalux (p148/149), Mink (63) & Sable (p62). Waiting Rooms Buccaneer (p179 & 218), Kalico (p77), RDL (p208), Circo (p220), Quadrant (p192), Quadring (p222), Aztec (p199), Flair (p143), Geneva (p36), Antares (p351), Recessed Tuscan (p153), Parkalux (p148/149), Mink (p63) & Sable (p62). Lost Property Kalico (p77), RDL (p208), Parkalux (p148/149), Sparta (p146/147), Metro (p144) & Flair (p143). Plant Rooms Parkalux (p148/149), Sparta (p146/147), Mink (63), Recessed Tuscan (p153), Quadrant (p192), Quadring (p222), Kalico (p77) & RDL (p208). Administration Offices Mink (p63), Sable (p62), Isis (p34), Venito (p35), Zermatt (p46/47), Geneva (p36/37), County (p48/49), Kalico (p77) & RDL (p208).
Parkalux (p148/149) Sable (p62)

385

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Platforms Platforms often require special fittings to suit particular site conditions. For example a unit to fit within a specially constructed ceiling or a fitting manufactured to ensure that no glare appears on a T.V. screen when single operator trains are in operation. We have regularly worked with designers to solve the issues raised by local conditions & either modified a standard fitting or designed & manufactured a Bespoke solution. A few examples are offered on this page however the available adaptations & designs are endless, simply, what is needed will be provided. Fittings that are typically used for platforms include: Parkalux (p148/149), Abrams (p165), Sparta (p146/147), Camasys (p162), Metro (p144), Recessed Tuscan (p153), Antares (p351) & Deluxe Brunel (p201) & derivations thereof.

Abrams (p165)

386

Rolling Stock Locations


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
The areas where work upon locomotives and rolling stock takes place a re often prone to particularly arduous working environments. For this reason modified versions of otherwise standard fittings have been developed over time to ensure that these conditions can be coped with. Full details of these alterations can be obtained from our technical sales office and we recommend that customers discuss their particular re q u i rements with our technical office to ensure that the corre c t solution is achieved 020.8254.2022. Maintenance Sheds Tuscan M8887, Sterilux (p353), QL Sterilux (p354/355) & Six Pack (p352). Washing Plants Tuscan M8887, Sterilux (p353) & QL Sterilux (p354/355). Inspection Pits Tuscan M8887. Workshops Sparta (p146/147), Sterilux (p353), Kalico (p77), RDL (p208), & Four or Six Pack (p352).

Signal Boxes Inside Mink (p63), Sable (p62), County (p48/49), Geneva (p36/37), Zermatt (p46/47), Kalico (p77) & RDL (p208). Outside Pantheon (p205), Buccaneer (p179 & 218), Quadrant (p192), Quadring (p222) & Tuscan II (p159). General Signs See pages 319/323.

Pantheon (p205)

Round QL Sterilux (p354)

387

Underground Railway Systems


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
In a similar way to our experience of working with those involved in surface railway networks we have for many years worked closely with designers & engineers on Underground railway system projects. Most often with London Underground Staff and their appointed design consultants & contractor partners, but also extensively with the New York & Paris Metro & Hong Kong MTR engineers. Notable projects completed in recent times by Designplan are the relighting of the entire metro system for the City of Liverpool, the supply of all lighting for the newly built North End Access, at Grand Central Station, New York City, a contract worth in excess of $1m & the complete refurbishment of the following underg round stations in London, Kennington, Tu ffnell Park, St. Johns Wood, Chalk Farm, Manor House and others. There are similarities between the lighting requirements for Surface & Underground systems but there are also differences. Both require equipment built to last many years that are simple to install & maintain. Both need fittings that have high IP & IK ratings, weather & strength properties, and both often require an input of Bespoke design & manufacture to ensure that the special needs of each are built into the equipment. One of the more significant differences is that for many underground projects glass is preferred for the diffusing material in front of lamps. Where this is needed we have adapted standard fittings, for example our Quadrant & Tuscan ranges, to meet this requirement or designed purpose made fittings with glass diffusers & cable management facilities built in. In the case of London Underground there is a difference between the requirements & standards below surface, designated Section 12 and above surface, non-section 12. The information that follows will, we believe, assist those working on & designing Underground Railway Systems and will enable the engineer or architect to select a suitable fitting that has often been specifically designed for this purpose. Where we have a fitting which has been specifically adapted for use or designed for Underground Systems we provide the specification within the following pages, otherwise we refer to the page number referring to the fitting recommended. If your project requires a Bespoke solution please refer to page 357.

388

Surface, non section 12 areas


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
Station entrance canopies Fittings required can be surface, semi-recessed or fully recessed. The Deluxe Brunel (p201) & Aztec (p199) are available in all three options. The Tuscan range (p153) most often used in recessed form or if a downlighting solution is sought the RDL (p208) is a weather & vandal resistant answer. Station exteriors Fittings used to light the outsides of station buildings need to be both weather & vandal resistant. The following list has been selected with both of these criteria in mind but also, in a number of cases, with aesthetic appearance playing an important role. The list provided is extensive reflecting the wide range that we manufacture offering the selected features mentioned above, most of which are available with our Lifetime Guarantee, see page 29. A number are available in surface, semi-recessed & fully recessed designs. Pantheon (p205), Capella (p260), Ali Quadgrille (p190/191), Quadgrille (p194/195), Quay (p232), Maxi Callisto (p256), Vertigo (p252/255), Ziggy (p261), Cloister (p250), RDL (p208), Wall Mount Brunel (p204), Corner Brunel (p202), Corner Quadrangle (p196), Hood (p245), Brunangle (p204) & Quadrato (p183). Emergency Lighting The majority of fittings mentioned can be provided with self-contained, central Battery or mains backup emergency & Auto test facilities as described on pages 313 & 314 In addition we have a number specifically adapted to below surface, section 12, requirements details of which are provided in the section 12 part of the guide. Concourse Area & Ticket Halls This is often a particularly busy part of a station and needs to be well lit. It is also the area where, at times, designers take the opportunity to c reate some diff e rences in lighting style, since many other locations, particularly below surface, tend very much to adopt similar equipment & aesthetic appearance. We frequently work with designers to modify existing fittings from our range or create new ideas for concourse areas. Where more standard equipment is chosen then versions of Camasys (p162), Metro (p144), Flair (p143), Mission (p145), Tuscan (p153), often modified, are installed. Also if recessed downlighting is needed one of our RDL (p208) range. 389
An installation using Piccadilly Piccadilly (p397) Pantheon (p205)

Surface, non section 12 areas


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
Staff areas & offices. Whilst standard recessed modular fittings (p64) may be suitable or recessed fittings to suit LG3 or LG7 requirements may be needed, for example our Sable (p62), there are a number of areas within Underg ro u n d facilities for which a special fitting to IP21 is pre f e r red. Scipio has been designed in conjunction with London Underg round engineers to meet the need where it is felt that a limited degree of water seepage can occur. There are two fittings currently available in the Scipio range. Scipio 1: A trough reflector type fitting with closed ends to the trough. All joints are fully welded & the high frequency control gear is mounted upon the back of the trough. This is then recessed into the body with an internal flange onto which the trough sits. There is fused plug & socket connection to the terminal block sited in the back of the body. End cable entry is provided which should be used with a suitable cable gland. The back of the body has no piecing in it & the fitting is installed using external brackets that are welded to the body ends. The fitting body & reflector are finished white polyester powder coat. Lamp size D944/26HFM10242 D944/16HFM10242
Scipio 1

270w 170w 258w 158w 236w 136w 218w 118w

D944/25HFM10242 D944/15HFM10242 D944/24HFM10242 D944/14HFM10242 D944/22HFM10242 D944/12HFM10242

Scipio 2: A recessed modular suitable for 600mm 600mm square ceiling grid. The fitting has no holes in the rear, recessed, part that could allow water in & it is of an all welded construction to seal against water entry. Louvres are mounted within a perforated front plate that is retained on wishbone springs. High frequency control gear & lamps are above the removable section on a demountable tray with a fused plug & socket connection to a terminal block in the back of the body. 20mm cable entry is provided adjacent to the terminal block which when used should be fitted with a suitable cable gland. Lamp size D916/2PL24LHFM10243 D916/2PL36LHFM10243
Scipio 2

224wPLL 236wPLL

For surface version add suffix A.

390

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Walkways Increasingly lighting combined with cable management facilities are being utliised. Running services within a single unit saves installation costs, makes maintenance a more simple task and enables significant improvements in the overall aesthetic look of an area to be achieved. Working with customers we have either provided standard answers via, for example, Camasys (p162), or modified other fittings, Metro (p144), Tuscan (p153) and others. Where requested purpose built solutions have been designed & manufactured see Bespoke manufacture (p357). Where a walkway is some distance from the actual station then the risk of damage from vandalism rises and a number of our fittings are well suited to provide years of trouble free life, each available with our lifetime guarantee p29. Toilets Depending upon the frequency of use, the cleaning and maintenance regime and the location, toilets & washrooms can be perfectly well lit with normal lighting. However, in some cases, they may need to be provided with a more robust solution where vandalism is possible. The following fittings are therefore ideally suited where normal conditions are expected, Kalico (p77), Mink (p63), Geneva (p36/37) Script (p54). If damage is a possibility then the following will provide protection, RDL (p208), Buccaneer (p179 &218), Circo (p220), Quadrant (p192), Quadring (p220), Aztec (p199), Antares (p351), Recessed Tuscan (p153), Parkalux (p148/149) or Abrams No-Body (p332). Stairways Staircases poorly lit inevitably lead to the possibility of accidents & certainly give rise to feelings of insecurity, there f o re good lighting is essential usually with the provision of an emergency facility included. Both Tuscan (p153) & Rampart (p166), will be suitable for stairways but in addition consideration may be given to Ali Quad (p188/189), Quadrant (p192) & Quadring (p222). Whilst there are a significant number of other fittings that would be suitable for stairways the ones suggested are available for non section 12 with polycarbonate diffusers as well as with matching glass diffusers to comply with section 12 which will allow the designer to carry through the same design both above & below surface. Lost Property Kalico (p77), RDL (p208), Mink (p63), Sable (p62), Parkalux (p148/149) & Sparta (p146/147). Plant Rooms Mink (p63), Buccaneer (p179 & 218), Geneva (p36/37), T5 Monitor (p151), Tuscan (p153), Quadrant (p192), Quadring (p222) & RDL (p208). 391

Rolling Stock Locations.


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
The areas where work upon trains and rolling stock takes place are often prone to particularly arduous working environments. For this reason modified versions of otherwise standard fittings have been developed over time to ensure that these conditions can be coped with. Full details of these alterations can be obtained from our technical sales office 020.8254.2022. Maintenance Sheds Tuscan M8887, Sterilux (p353) &QL Sterilux (p354) Six Pack (p352). Washing Plants Tuscan M8887, Sterilux (p353) &QL Sterilux (p354). Inspection Pits Tuscan M8887. Workshops Sparta (p146/147), Sterilux (p353) & RDL (p208) Six Pack (p352).

Round QL Sterilux (p287)

Sterilux (p286)

392

Below Surface, Section 12 areas


SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE
Where fittings are to be installed below surface, London Underground have attached the designation Section 12 to which such equipment must comply. There a number of features that are required in order for compliance to be achieved the most notable being cable to be of a low smoke & fume type, all glazing to be glass & paints used must meet strict requirements called up in standard E1042. L.E.D. Lighting L.E.D. lighting is becoming ever more popular as the solution to the lighting or highlighting of particular areas. We have a standard range of wall & inground L.E.D. fittings (p107/137) that may be useful for underground as well as above ground areas. Again, as with all of our range, special & bespoke (p357) fittings can be provided to meet specific requirements. Use catalogue number from standard page & add suffix M8277T for the section 12 adaptations. Escalators Escalators often start above surface but all end below & there f o re section 12 type fittings are likely to be required. RDL (p208), Bastion (p170), Bricklight (p173) , Centaur LED (110), Topaz (p128), Camasys (p162) & Antares (p351) each with a glass option, would be suitable. Use catalogue number from standard page & add suffix M8277T for the section 12 adaptations. Plant Rooms Mission M8277T (p398), Tuscan M8277T (p396), Quadrant M8277T (p397), Quadring M8277T (p397) & RDL M8277T (p208). Use catalogue number from standard page & add suffix M8277T for the section 12 adaptations. In-ground If an in-ground fitting is re q u i re then our Centaur range (p300) or Centaur d with L.E.D. lamps (p109) may be the solution. Use catalogue number fro m standard page & add suffix M8277T for the section 12 adaptations. Tunnels There are some areas in the underground network of tunnels that require lighting. For these a special fitting has been developed. Simplon IP65: Body in die cast aluminium finished in black powder coat, secured to stainless steel fixing plate. High frequency control gear and lamp on removable gear tray with plug & socket connector to ease installation & maintenance (Particularly important in these areas). Glass control lens providing light output in linear pattern along length of tunnel. Catalogue Number SIM142PLTLHF Lamp size 142w PLT
Simplon RDL (p208)

Other lamp options available, please contact our technical sales office. Photometric data contact our technical sales office. Available pre-wired for rapid installation, contact technical sales office for further information. 393

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


The lighting of platforms has many & varied solutions entirely dependent upon the requirements & ideas of the particular designer or engineer involved. Over the past thirty & more years Designplan has worked with engineers in many countries to provide the ideal answer to the particular challenge posed by each specific platform to be lit. For this reason it is almost impossible to give a definitive answer as to what fitting to use for platforms. For general guidance more often than not a version of either Camasys (p162), Antares (p315) or Tuscan (p153) are the chosen products. Invariably the standard fitting is modified to a greater or lesser degree so that the ideal solution is arrived at. See also our Bespoke Tuscan (p164) & Bespoke Manufacture (p357). For guidance & as a starting point a recent platform installation at Manor House underground station, London, used Camasys cable management system (p162) . The lighting system incorporates two side wings which hinge to reveal cable ways and allow re-lamping. The specification included the standard section 12 features as mentioned at the beginning of this part of the guide, and quick release quarter turn fasteners for the wings, In addition to this hinging facility each fitting can be designed to be able to be individually isolated for maintenance & relamping, another an important factor in platform situations. The reason for quick release is simply that maintenance in underg ro u n d areas can only be carried out at very limited times & the faster & easier it is for the maintenance to be completed the better & more cost effective the work. In addition a reflector in anocoil aluminium was used to provide maximum e fficiency. In this case the lamps chosen were 2 55wPL. The IP rating, IP65, to ensure that dust, always an issue in platform areas, was kept out of the fitting. To assist cleaning a special gloss powder finish was selected. Platform Public help points have been successfully highlighted using our Maxi Callisto (p398) with either CDMT or compact fluorescent lamps, all section 12 compliant. This angled fitting lends itself to simple installation on the tunnel curve to highlight the now numerous help points. Refer to page 162 for Camasys lighting and cable management system.

394

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Tuscan M10280. IP65 Lamp size D840/2PL55LM10280 D840/2PL40LM10280 255wPLL 240wPLL

Additional fittings which can be incorporated within similar cable management systems. D850 Tuscan Standard fitting specification page 158. D850/26M10280 D850/16M10280 D850/25M10280 D850/15M10280 D850/24M10280 D850/14M10280 270wT8 170wT8 258wT8 158wT8 236wT8 136wT8

D810 T5 Tuscan Standard fitting specification page 154. High efficiency D810/114T5 M10280 D810/214T5 M10280 D810/121T5 M10280 D810/221T5 M10280 D810/128T5 M10280 D810/228T5 M10280 D810/135T5 M10280 D810/235T5 M10280 Lamp size 114w 214w 121w 221w 128w 228w 135w 235w High output D810/124T5 M10280 224w not available D810/139T5 M10280 239w not available D810/154T5 M10280 254w not available D810/149T5 M10280 249w not available 149w 154w 139w Lamp size 124w

For the addition of self contained emergency facility add suffix 058, however more often a central battery system is preferred for underground facilities. Details of this option can be found on page 313.

395

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE

Other Current Section 12 compliant fittings

Linear Tuscan M10492 IP65 Based upon Tuscan (p158) type fitting with square sides to the body. Heavy gauge steel frame housing a toughened glass panel. The frame is held against gasket by toggle latches which allow hinging of frame for maintenance & relamping. An optional louvre, manufactured in aluminium, can be fitted behind the glass panel. Standard finish RAL9006 silver. Without louvre D850/26M10492 D850/16M10492 D850/25M10492 D850/15M10492 D850/24M10492
Standard Tuscan (not M10492)

Lamp size 270w 170w 258w 158w 236w 136w

With louvre D850/26M10492A D850/16M10492A D850/25M10492A D850/15M10492A D850/24M10492A D850/14M10492A

D850/14M10492

D840 Tuscan 10492 (Standard fitting specification page 156.) Without louvre D840/2PL55LM10492 D840/2PL40LM10492 Lamp size 255wPLL 240wPLL

D810 T5 Tuscan 10492 (Standard fitting specification page 154.) High efficiency D810/114T5M10492 D810/214T5M10492 D810/121T5M10492 D810/221T5M10492 D810/128T5M10492 D810/228T5M10492 D810/135T5M10492 D810/235T5M10492 With louvre add suffix A Additionally to the above any Tuscan fitting can be provided with section 12 modifications, simply specify catalogue number of fitting wanted & add M8277 (frosted glass) to the chosen number. If clear glass is preferred add M8277T or for Georgian Wired glass M8277M. If, in place of toggle latches, security screws are required to secure diffuser frame add suffix C. For security screw & louvre suffix D. Lamp size 114w 214w 121w 221w 128w 228w 135w 235w High output D810/124T5M10492 224w not available D810/139T5M10492 239w not available D810/154T5M10492 254w not available D810/149T5M10492 249w not available 149w 154w 139w Lamp size 124w

396

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Quadrant. IP65 Manufactured to general the specification of Quadrant (p192) but having section 12 requirements (glass diffuser). High Frequency Clear patterned DQ382DLPHFBM8277T DQ282DLPHFBM8277T DQ212DLPHFBM8277T DQ162DLPHFBM8277T DQ2PL9LPHFBM8277T Lamp size 138w2D 128w2D 121w2D 116w2D 29wPL
Quadrant Quadring

Semi recessed add suffix V in place of T Fully recessed add suffix W in place of T Frosted diffuser, at extra cost, delete T & add suffix X Photometric data see page 471 A wall mounted angle version, generally as p193, but to section 12 as right is available - add suffix M2877T to chose Quadrangle number.
Piccadilly Quadrangle

Quadring. IP65 Manufactured to general the specification of Quadring (p222) but having section 12 requirements (glass diffuser). High Frequency Clear patterned RB382DLPHFBM8277T RB282DLPHFBM8277T RB162DLPHFBM8277T RB2PL11LPHFBM8277T RB2PL9LPHFBM8277T Lamp size 138w2D 128w2D 116w2D 211wPL 29wPL

Semi recessed add suffix V in place of T Fully recessed add suffix W in place of T Frosted diffuser, at extra cost, delete T & add suffix X Photometric data see page 471 Piccadilly. IP65 Zinc coated steel body finished in textured white powder coat. High frequency control gear mounted upon removable tray with plug & socket connector block. Patterned glass diffuser held against gasket by stainless steel screws. Manufactured to section 12 requirements. Lamp size PIC324PLHFW 324wPL Semi recessed add suffix SR. Fully recessed add suffix R Photometric data contact our technical sales office 020.8254.2022 397

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Mission IP65 Manufactured to the general specification of Mission (p145) but having section 12 requirements (glass diffuser). Please note that at date of going to press London Underground in general did not sanction the use of T5 lamps. Please seek up to date information before specifying their use.
Mission Maxi Callisto

T8 Lamps High frequency D599/15HF M8277T D599/14HF M8277T D599/12HF M8277T T5 Lamps High efficiency D599/114T5M8277T
FSRDL

Lamp size 158w 136w 118w

High output D599/25HF M8277T D599/24HF M8277T D599/22HF M8277T

Lamp size 258w 236w 218w

Lamp size 114w 214w 121w 221w 128w 228w 135w 235w

High output D599/124T5 M8277T D599/224T5 M8277T D599/139T5 M8277T D599/239T5 M8277T D599/154T5 M8277T D599/254T5 M8277T D599/149T5 M8277T D599/249T5 M8277T

Lamp size 124w 224w 139w 239w 154w 254w 149w 249w

D599/214T5 M8277T D599/121T5 M8277T D599/221T5 M8277T D599/128T5 M8277T D599/228T5 M8277T D599/135T5 M8277T D599/235T5 M8277T Maxi Callisto IP65

General specification, as shown on page 256 but each fitting to be modified to section 12 requirements. Discharge XCAL70CDMTLM8277U XCAL35CDMTLM8277U High frequency XCAL1PLT18LHFM8277U Switch start XCAL1PLT18LM8277U Lamp size 170wCDMT 135wCDMT Lamp size 118wPLT Lamp size 118wPLT

For white finish add suffix W. For Satin Silver finish add suffix C29 For top cable entry add suffix TH FSRDL IP65 Downlighter range as described on pages 212 to 214 but manufactured to include section 12 requirements. Simply select fitting number required & add suffix M8277T. 398

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Callisto IP55 General specification, as shown on page 258 but each fitting to be modified to section 12 requirements. Lamp size MR1612v CAL50IRC60M8277U CAL50IRC38M8277U CAL50IRC24M8277U CAL50IRC10M8277U CAL35IRC60M8277U CAL35IRC38M8277U CAL35IRC24M8277U CAL35IRC10M8277U CAL20IRC38M8277U CAL20IRC10M8277U For white finish add suffix W For Satin Silver finish add suffix C29 Semi recessed version add suffix SR L.E.D. versions available see page 127 Supplied with lamps. Note: As with all Tungsten fittings the external case temperature will get hot. However the L.E.D. version runs cool. Quadrato IP65 Cast aluminium body & hood finished in matt black powder coat. High frequency control gear mounted upon removable tray with plug & socket connector block. Glass panel held against gasket by stainless steel scre w s . Manufactured to section 12 requirements. Surface QTO1PLC18LM8277U QTO1PLC26LM8277U QTO70SONLM8277U QTO75MALM8277U Lamp size 118wPLC 126wPLC 170wSON 175wMAL Semi-recessed QTO1PLC18LSRM8277U QTO1PLC26LSRM8277U QTO70SONLSRM8277U QTO75MALSRM8277U 50w 50w 50w 50w 35w 35w 35w 35w 20w 20w 60deg 38deg 24deg 10deg 60deg 38deg 24deg 10deg 38deg 10deg
Callisto Quadrato

Lamp angle

Photometric data see page 471.

399

SURFACE & UNDERGROUND RAILWAY SYSTEMS LIGHTING GUIDE


Centaur. IP65 In-ground range as described on page 300 but manufactured to include section 12 requirements. L.E.D. versions see page 109. Simply select fitting number required & add suffix M8277U. Curso IP55 Recessed wall mounting fitting as described on page 259 but manufactured to include section 12 requirements. L.E.D. versions see
Curso

page 127. Simply select fitting number required & add suffix M8277U. Emergency Exit Signs, self-contained In conjunction with London Underground engineers two self-contained 3hour duration emergency exit units have been developed. Zinc coated steel body finished in textured white powder coat. Control gear, batteries & module mounted upon removable tray with plug & socket connector block. Glass panel within steel frame held against gasket by stainless steel screws. Manufactured to section 12 requirements. Maintained. (normal mains operation & emergency operation). Lamp size M1977 111wPL

Non-Maintained (no light available in normal times, emergency operation only).


M1977/M3981

Lamp size M1897 111wPL

To the above catalogue numbers simply add the correct suffix for chosen sign.
M3981 M3982 M3983 M3984

M3981 M3982 M3983 M3984 Other signs or symbols available upon request. If fittings are wanted without signage simply specify the catalogue number but with no additional suffix. If Auto-test facility on the maintained emergency circuit is required add suffix M5780 (full details see page 314). This is not available for nonmaintained fittings.

400

S-ar putea să vă placă și