Sunteți pe pagina 1din 32

SUMMER TRAINING REPORT

12July to 24 August2011

Submitted By:Ankit Sharma B.Tech, 3rdYear Guru Premsukh Memorial College of Engineering

Certificate

This is to certify that Mr. Ankit Sharma, Student of Guru Premsukh Memorial college of Engineering, GGSIPU, pursuing Bachelors of Technology in Mechanical and Automation Engineering, 3nd year has successfully completed his summer training at BTPS NTPC , New Delhi from 12th July 2010 to 20 August 2011. He has completed the whole training as per

the training report submitted by him.

Training In-charge Badarpur Thermal Power Station NTPC, Badarpur New Delhi

ACKNOWLEDGEMENT

With profound respect and gratitude, I take the opportunity to convey my thanks to complete the training here. I express gratitude to the Mechanical and Automation Department of Guru Premsukh Memorial college of Engineering ,Delhi for providing this opportunity to undergo industrial training at National Thermal Power Corporation, Badarpur, New Delhi. I am extremely grateful to all the technical staff of BTPS-NTPC for their co-operation and guidance that helped me a lot during the course of training. I have learnt a lot working under them and I will always be indebted of them for this value addition in me.

Finally, I am indebted to all whosoever have contributed in this report work andfriendly stay at Badarpur Thermal Power Station, Badarpur, New Delhi.

Contents
1. About the Company 2. Thermal Power Plant 1. Introduction 2. Operation

3. Functioning 3.Electricity Generation Process 4.PAM 5. CHD/NCHP

CORPORATE VISION
A world class integrated power major, powering India's growth with increasing global

presence.

NTPC Limited is the largest thermal power generating company of India, Public Sector Company. It was incorporated in the year 1975 to accelerate power development in the country as a wholly owned company of the Government of India. At present, Government of India holds 89.5% of the total equity shares of the company and the balance 10.5% is held by FIIs, Domestic Banks, Public and others. The total installed capacity of the company is 31134 MW (including JVs) with 15 coal based and 7 gas based stations, located across the country.

By 2017, the power generation portfolio is expected to have a diversified fuel mix with coal based capacity of around 53000 MW, 10000 MW through gas, 9000 MW through Hydro generation, about 2000 MW from nuclear sources and around 1000 MW from Renewable Energy Sources (RES).

A Graphical Overview

THERMAL POWER PLANT

INTRODUCTION
Power Station (also referred to as generating station or power plant) is an industrial facility for the generation of electric power. Power plant is also used to refer to the engine in ships, aircraft and other large vehicles. Some prefer to use the term energy center because it more accurately describes what the plants do, which is the conversion of other forms of energy, like chemical energy, gravitational potential energy or heat energy into electrical energy. However, power plant is the most common term in the U.S., while elsewhere power station and power plant are both widely used, power station prevailing in many Commonwealth countries and especially in the United Kingdom.

A coal-fired Thermal Power Plant At the center of nearly all power stations is a generator, a rotating machine that converts Mechanical energy into Electrical energy by creating relative motion between a magnetic field and a conductor. The energy source harnessed to turn the generator varies widely. It depends chiefly on what fuels are easily available and the types of technology that the power company has access to. In thermal power stations, mechanical power is produced by a heat engine, which transforms Thermal energy (often from combustion of a fuel) into rotational energy. Most thermal power stations produce steam, and these are sometimes called steam power stations. About 80% of all electric power is generated by use of steam turbines. Not all thermal energy can be transformed to mechanical power, according to the second law of thermodynamics. Therefore, there is always heat lost to the environment. If this loss is employed as useful heat, for industrial processes or district heating, the power plant is referred to as a cogeneration power plant or CHP (combined heat-and-power) plant. In countries where district heating is common, there are dedicated heat plants called heat-only boiler

stations. An important class of power stations in the Middle East uses by-product heat for desalinationof water.

CLASSIFICATION

By fuel
Nuclear power plants use a nuclear reactor's heat to operate a steam turbine generator. Fossil fuelled power plants may also use a steam turbine generator or in the case of natural gas fired plants may use a combustion turbine. Geothermal power plants use steam extracted from hot underground rocks. Renewable energy plants may be fuelled by waste from sugar cane, municipal solid waste, landfill methane, or other forms of biomass. In integrated steel mills, blast furnace exhaust gas is a low-cost, although low-energy density, fuel. Waste heat from industrial processes is occasionally concentrated enough to use for power generation, usually in a steam boiler and turbine.

By prime mover
Steam turbine plants use the dynamic pressure generated by expanding steam to turn the blades of a turbine. Almost all large non-hydro plants use this system. Gas turbine plants use the dynamic pressure from flowing gases to directly operate the turbine. Natural-gas fuelled turbine plants can start rapidly and so are used to supply "peak" energy during periods of high demand, though at higher cost than base-loaded plants. These may be comparatively small units, and sometimes completely unmanned, being remotely operated. This type was pioneered by the UK, Prince town being the world's first, commissioned in 1959. Combined cycle plants have both a gas turbine fired by natural gas, and a steam boiler and steam turbine which use the exhaust gas from the gas turbine to produce electricity. This greatly increases the overall efficiency of the plant, and many new base load power plants are combined cycle plants fired by natural gas. Internal combustion Reciprocating engines are used to provide power for isolated communities and are frequently used for small cogeneration plants. Hospitals, office buildings, industrial plants, and other critical facilities also use them to provide backup power in case of a power outage. These are usually fuelled by diesel oil, heavy oil, natural gas and landfill gas.

Micro turbines, Sterling engine and internal combustion reciprocating engines are low cost solutions for using opportunity fuels, such as landfill gas, digester gas from water treatment plants and waste gas from oil production.

FUNCTIONING
In a thermal power plant, one of coal, oil or natural gas is used to heat the boiler to convert the water into steam. The steam is used to turn a turbine, which is connected to a generator. When the turbine turns, electricity is generated and given as output by the generator, which is then supplied to the consumers through high-voltage power lines.

Detailed process of power generation in a thermal power plant:

1) Water intake: Firstly, water is taken into the boiler through a water source. If water is available in a plenty in the region, then the source is an open pond or river. If water is scarce, then it is recycled and the same water is used over and over again.

2) Boiler heating: The boiler is heated with the help of oil, coal or natural gas. A furnace is used to heat the fuel and supply the heat produced to the boiler. The increase in temperature helps in the transformation of water into steam.

3) Steam Turbine: The steam generated in the boiler is sent through a steam turbine. The turbine has blades that rotate when high velocity steam flows across them. This rotation of turbine blades is used to generate electricity.

4) Generator: A generator is connected to the steam turbine. When the turbine rotates, the generator produces electricity which is then passed on to the power distribution systems.

5) Special mountings: There is some other equipment like the economizer and air pre-heater. An economizer uses the heat from the exhaust gases to heat the feed water. An air pre-heater heats the air sent into the combustion chamber to improve the efficiency of the combustion process.

6) Ash collection system: There is a separate residue and ash collection system in place to collect all the waste materials from the combustion process and to prevent them from escaping into the atmosphere. Apart from this, there are various other monitoring systems and instruments in place to keep track of the functioning of all the devices. This prevents any hazards from taking place in the plant.

CAPACITY OF NTPC-BTPS PLANT

Overview of Coal Based Thermal Power Plant

There are basically three main units of a thermal power plant: 1. Steam Generator or Boiler 2. Steam Turbine 3. Electric Generator

We have discussed about the processes of electrical generation further. A complete detailed description of two (except 2) units is given further.

Coal is conveyed (14) from an external stack and ground to a very fine powder by large metal spheres in the pulverised fuel mill (16). There it is mixed with preheated air (24) driven by the forced draught fan (20). The hot air-fuel mixture is forced at high pressure into the boiler where it rapidly ignites. Water of a high purity flows vertically up the tube-lined walls of the boiler, where it turns into steam, and is passed to the boiler drum, where steam is separated from any remaining water. The steam passes through a manifold in the roof of the drum into the pendant super heater (19) where its temperature and pressure increase rapidly to around 200 bar and 540C, sufficient to make the tube walls glow a dull red. The steam is piped to the high pressure turbine (11), the first of a three-stage turbine process. A steam governor valve (10) allows for both manual control of the turbine and automatic set-point following. The steam is exhausted from the high pressure turbine, and reduced in both pressure and temperature, is returned to the boiler reheater (21). The reheated steam is then passed to the intermediate pressure turbine (9), and from there passed directly to the low pressure turbine set (6). The exiting steam, now a little above its boiling point, is brought into thermal contact with cold water (pumped in from the Cooling tower) in the condenser (8), where it condenses rapidly back into water, creating near vacuum-like conditions inside the condensor chest. The condensed water is then passed by a feed pump (7) through a deaerator (12), and pre-warmed, first in a feed heater (13) powered by steam drawn from the high pressure set, and then in the economiser (23), before being returnedto the boiler drum. The cooling water from the condensor is sprayed inside a cooling tower (1), creating a highly visible plume of water vapour, before being pumped back to the condensor (8) in cooling water cycle. The three turbine sets are sometimes coupled on the same shaft as the three-phase electrical generator (5) which generates an intermediate level voltage (typically 20-25 kV). This is stepped up by the unit transformer (4) to a voltage more suitable for transmission (typically 250-500 kV) and is sent out onto the three-phase transmission system (3). Exhaust gas from the boiler is drawn by the induced draft fan (26) through an electrostatic precipitator (25) and is then vented through the chimney stack (27).

Coal Handling Department

Coal is delivered by highway truck, rail, barge or collier ship. Some plants are even built near coal mines and coal is delivered by conveyors. A large coal train called a "unit train" may be a kilometres (over a mile) long, containing 60 cars with 100 tons of coal in each one, for a total load of 6,000 tons. A large plant under full load requires at least one coal delivery this size every day. Plants may get as many as three to five trains a day, especially in "peak season", during the summer months when power consumption is high. A large thermal power plant such as the Badarpur Thermal Power Station, New Delhi stores several million tons of coal for use when there is no wagon supply.

Coal Handling Plant Layout

Modern unloaders use rotary dump devices, which eliminate problems with coal freezing in bottom dump cars. The unloader includes a train positioner arm that pulls the entire train to position each car over a coal hopper. The dumper clamps an individual car against a platform that swivels the car upside down to dump the coal. Swivelling couplers enable the entire operation to occur while the cars are still coupled together. Unloading a unit train takes about three hours. Shorter trains may use railcars with an "air-dump", which relies on air pressure from the engine plus a "hot shoe" on each car. This "hot shoe" when it comes into contact with a "hot rail" at the unloading trestle, shoots an electric charge through the air dump apparatus and causes the doors on the bottom of the car to open, dumping the coal through the opening in the trestle. Unloading one of these trains takes anywhere from an hour to an hour and a half. Older unloaders may still use manually operated bottom-dump rail cars and a "shaker" attached to dump the coal. Generating stations adjacent to a mine may receive coal by conveyor belt or massive diesel electric-drive trucks.

Coal is prepared for use by crushing the rough coal to pieces less than 2 inches (50 mm) in size. The coal is then transported from the storage yard to in-plant storage silos by rubberized conveyor belts at rates up to 4,000 tons/hour. In plants that burn pulverized coal, silos feed coal pulverisers (coal mill) that take the larger 2 inch pieces grind them into the consistency of face

powder, classify them, and mixes them with primary combustion air which transports the coal to the furnace and preheats the coal to drive off excess moisture content. In plants that do not burn pulverized coal, the larger 2 inch pieces may be directly fed into the silos which then feed the cyclone burners, a specific kind of combust or that can efficiently burn larger pieces of fuel.

Run-Of-Mine (ROM) Coal


The coal delivered from the mine that reports to the Coal Handling Plant is called Run-of-mine, or ROM, coal. This is the raw material for the CHP, and consists of coal, rocks, middlings, minerals and contamination. Contamination is usually introduced by the mining process and may include machine parts, used consumables and parts of ground engaging tools. ROM coal can have a large variability of moisture and maximum particle size.

Coal Handling
Coal needs to be stored at various stages of the preparation process, and conveyed around the CHP facilities. Coal handling is part of the larger field of bulk material handling, and is a complex and vital part of the CHP.

Stockpiles
Stockpiles provide surge capacity to various parts of the CHP. ROM coal is delivered with large variations in production rate of tonnes per hour (tph). A ROM stockpile is used to allow the wash plant to be fed coal at lower, constant rate. Simple stockpile is formed by machinery dumping coal into a pile, either from dump trucks, pushed into heaps with bulldozers or from conveyor booms. More controlled stockpiles are formed using stackers to form piles along the length of a conveyor, and reclaimers to retrieve the coal when required for product loading, etc. Taller and wider stockpiles reduce the land area required to store a set tonnage of coal. Larger coal stockpiles have a reduced rate of heat lost, leading to a higher risk of spontaneous combustion.

Stacking
Travelling, lugging boom stackers that straddle a feed conveyor are commonly used to create coal stockpiles. Stackers are nominally rated in tph (tonnes per hour) for capacity and normally travel on a rail between stockpiles in the stockyard. A stacker can usually move in at least two directions typically: horizontally along the rail and vertically by luffing its boom. Luffing of the boom minimises dust by reducing the height that the coal needs to fall to the top of the stockpile. The boom is luffed upwards as the stockpile height grows.

Wagon Tripler at Badarpur Thermal Power Station, New Delhi

Some stackers are able to rotate by slewing the boom. This allows a single stacker to form two stockpiles, one on either side of the conveyor. Stackers are used to stack into different patterns, such as cone stacking and chevron stacking. Stacking in a single cone tends to cause size segregation, with coarser material moving out towards the base. Raw cone ply stacking is when additional cones are added next to the first cone. Chevron stacking is when the stacker travels along the length of the stockpile adding layer upon layer of material. Stackers and Reclaimers

were originally manually controlled manned machines with no remote control. Modern machines are typically semi-automatic or fully automated, with parameters remotely set.

Reclaiming
Tunnel conveyors can be fed by a continuous slot hopper or bunker beneath the stockpile to reclaim material. Front-end loaders and bulldozers can be used to push the coal into feeders. Sometimes front-end loaders are the only means of reclaiming coal from the stockpile. This has a low up-front capital cost, but much higher operating costs, measured in dollars per tonne handled.

Coal Storage Area of the Badarpur Thermal Power Station, New Delhi

High-capacity stockpiles are commonly reclaimed using bucket-wheel reclaimers. These can achieve very high rates.

Coal Sampling
Sampling of coal is an important part of the process control in the CHP. A grab sample is a one off sample of the coal at a point in the process stream, and tends not to be very representative. A routine sample is taken at a set frequency, either over a period of time or per shipment.

Screening
Screens are used to group process particles into ranges by size. These size ranges are also called grades. Dewatering screens are used to remove water from the product. Screens can be static, or mechanically vibrated. Screen decks can be made from different materials such as high tensile steel, stainless steel, or polyethylene.

Screening and Separation Unit of Coal Handling Division

Magnetic Separation
Magnetic separators shall be used in coal conveying systems to separate tramp iron (including steel) from the coal. Basically, two types are available. One type incorporates permanent or electromagnets into the head pulley of a belt conveyor. The tramp iron clings to the belt as it goes around the pulley drum and falls off into a collection hopper or trough after the point at which coal is charged from the belt. The other type consists of permanent or electromagnets incorporated into a belt conveyor that is suspended above a belt conveyor carrying coal. The tramp iron is pulled from the moving coal to the face of the separating conveyor, which in turn holds and carries the tramp iron to a collection hopper or trough. Magnetic separators shall be used just ahead of the coal crusher, if any, and/or just prior to coal discharge to the in-plant bunker or silo fill system.

Coal Crusher
Before the coal is sent to the plant it has to be ensured that the coal is of uniform size, and so it is passed through coal crushers. Also power plants using pulverized coal specify a maximum coal size that can be fed into the pulverizer and so the coal has to be crushed to the specified size using the coal crusher. Rotary crushers are very commonly used for this purpose as they can provide a continuous flow of coal to the pulverizer.

Pulverizer
Most commonly used pulverizer is the Boul Mill. The arrangement consists of 2 stationary rollers and a power driven boul in which pulverization takes place as the coal passes through the sides of the rollers and the boul. A primary air induced draught fan draws a stream of heated air through the mill carrying the pulverized coal into a stationary classifier at the top of the pulverizer. The classifier separates the pulverized coal from the unpulverized coal.

Advantages of Pulverized Coal


Pulverized coal is used for large capacity plants. It is easier to adapt to fluctuating load as there are no limitations on the combustion capacity. Coal with higher ash percentage cannot be used without pulverizing because of the problem of large amount ash deposition after combustion.

Increased thermal efficiency is obtained through pulverization.

An external view of a Coal Pulverizer

The use of secondary air in the combustion chamber along with the powered coal helps in creating turbulence and therefore uniform mixing of the coal and the air during combustion. Greater surface area of coal per unit mass of coal allows faster combustion as more coal is exposed to heat and combustion. The combustion process is almost free from clinker and slag formation. The boiler can be easily started from cold condition in case of emergency. Practically no ash handling problem. The furnace volume required is less as the turbulence caused aids in complete combustion of the coal with minimum travel of the particles. The pulverized coal is passed from the pulverizer to the boiler by means of the primary air that is used not only to dry the coal but also to heat is as it goes into the boiler. The secondary air is used to provide the necessary air required for complete combustion. The primary air may vary anywhere from 10% to the entire air depending on the design of the boiler. The coal is sent into the boiler through burners. A very important and widely used type of burner arrangement is the Tangential Firing arrangement.

TABLES OF CYCLES
1. COAL CYCLE

Tangential Burners
The tangential burners are arranged such that they discharge the fuel air mixture tangentially to an imaginary circle in the center of the furnace. The swirling action produces sufficient turbulence in the furnace to complete the combustion in a short period of time and avoid the necessity of producing high turbulence at the burner itself. High heat release rates are possible with this method of firing. The burners are placed at the four corners of the furnace. At the Badarpur Thermal Power Station five sets of such burners are placed one above the other to form six firing zones. These burners are constructed with tips that can be angled through a small vertical arc. By adjusting the angle of the burners the position of the fire ball can be adjusted so as to raise or lower the position of the turbulent combustion region. When the burners are tilted downward the furnace gets filled completely with the flame and the furnace exit gas temperature gets reduced. When the burners are tiled upward the furnace exit gas temperature increases. A difference of 100 degrees can be achieved by tilting the burners.

PLANT AUXILLIARY MAINTENANCE

Water circulation System:


Cooling towers
Cooling towers are eveporative coolers used for cooling water. Cooling tower use evaporation of water to reject heat from processes such as cooling the circulaing water used in oil refineries, chemical plants, power plants, etc. The tower vary in size from small roof top units to very large hyperboloid structures that can be upto 200 meters tall and 100 meters in diameter, or rectangular structure that can be over 40 meters tall and 80 meters long. Smaller towers are normally factory built while larger ones are constructed on site. The primary use of large, industrial cooling tower system is to remove the heat absorbed in the circulating water system used in power plants, petroleum refineries, petrochemical and chemical plants, natural gas processing plants and other industrial facilities. The absorbed heat is rejected to the atmosphere by the evaporation of some of the cooling water in mechanical forced draft or induced draft towers or in natural draft hyperbolic shaped cooling towers as seen at most nuclear power plants.

Heat transfer methods

With respect to the heat transfer mechanism employed, the main types are: Wet cooling towers or simply cooling towers operate on the principle of evaporation. The working fluid and the evaporated fluid (usually H2O) are one and the same. Dry coolers operate by heat transfer through a surface that separates the working fluid from ambient air, such as in a heat exchanger, utilizing convective heat transfer. They do not use evaporation Fluid coolers are hybrids that pass the working fluid through a tube bundle, upon which clean water is sprayed and a fan-induced draft applied. The resulting heat transfer performance is much closer to that of a wet cooling tower, with the advantage provided by a dry cooler of protecting the working fluid from environmental exposure.

ASH HANDLING PLANT


Fly Ash Collection
Fly ash is captured and removed from the flue gas by electrostatic precipitators or fabric bag filters (or sometimes both) located at the outlet of the furnace and before the induced draft fan. The fly ash is periodically removed from the collection hoppers below the precipitators or bag filters. Generally, the fly ash is pneumatically transported to storage silos for subsequent transport by trucks or railroad cars.

Bottom Ash Collection and Disposal


At the bottom of every boiler, a hopper has been provided for collection of the bottom ash from the bottom of the furnace. This hopper is always filled with water to quench the ash and clinkers falling down from the furnace. Some arrangement is included to crush the clinkers and for conveying the crushed clinkers and bottom ash to a storage site.

Ash Handling System at Badarpur Thermal Power Station, New Delhi

Water Treatment Plant


Boiler Make-up Water Treatment Plant and Storage
Since there is continuous withdrawal of steam and continuous return of condensate to the boiler, losses due to blow-down and leakages have to be made up for so as to maintain the desired water level in the boiler steam drum. For this, continuous make-up water is added to the boiler water system. The impurities in the raw water input to the plant generally consist of calcium and magnesium salts which impart hardness to the water. Hardness in the make-up water to the boiler will form deposits on the tube water surfaces which will lead to overheating and failure of the tubes. Thus, the salts have to be removed from the water and that is done by a Water Demineralising Treatment Plant (DM). A DM plant generally consists of cation, anion and mixed bed exchangers. The final water from this process consists essentially of hydrogen ions and hydroxide ions which is the chemical composition of pure water. The DM water, being very pure, becomes highly corrosive once it absorbs oxygen from the atmosphere because of its very high affinity for oxygen absorption.

The capacity of the DM plant is dictated by the type and quantity of salts in the raw water input. However, some storage is essential as the DM plant may be down for maintenance. For this purpose, a storage tank is installed from which DM water is continuously withdrawn for boiler make-up. The storage tank for DM water is made from materials not affected by corrosive water, such as PVC. The piping and valves are generally of stainless steel. Sometimes, a steam blanketing arrangement or stainless steel doughnut float is provided on top of the water in the tank to avoid contact with atmospheric air. DM water make-up is generally added at the steam space of the surface condenser (i.e., the vacuum side). This arrangement not only sprays the water but also DM water gets deaerated, with the dissolved gases being removed by the ejector of the condenser itself.