MV ring main units HV metering units LV transformer cabinets Package substations LV distribution pillars LV substation fuseboards Multi service

pillars Multi service distribution boards Heavy duty cutouts Domestic service cutouts Street lighting cutouts Pole mounting cutouts ABC service boxes Connector boxes Fuse links Weatherproof housings Earth fault indicators MV and HV disconnectors MV and HV connectors

ENGINEERING BRILLIANT SOLUTIONS

Cut- out solutions

A division of W Lucy & Co Ltd

Contents

HSCO House Service Cut-outs MLNS Connector Box SP, SPNE, TPNE Single Pole or Triple Pole, Neutral and Earth Cut-out

HDCO Heavy Duty Cut-outs MC300 Single Pole Cut-out 300A MC630 Three Phase & Neutral Cut-out 630A GF200/400/600 Three Phase & Neutral Cut-out 200A, 400A, 600A MPC400 Pole Mounted Cut-out ABC Service Box

11

MSDB Multi Service Distribution Boards Multi Service Distribution Boards Horizontal Busbar Arrangement Multi Service Distribution Boards Vertical Busbar Arrangement

13

Street Lighting Cut-outs SLF Single Phase Cut-out 25A

14

Accessories Fuse Accessories

HSCO House Service Cut-out


MLNS Connector box Features MLNS5
CONF ORM S T O B S 7 6 5 7 : 1 9 9 3 S P E C I F I C A T I O N

MLNS6
MOU LD E D IN B LA C K P H E N OLIC T H E R MOS E T MAT E RIAL

M OUL DE D I N GR E Y GL AS S F I L L E D E NG I N E E R I N G T HE RM OP L AS T I C

SIN G LE P OLE

6 WAY C ON N E C T OR B OX M OUL DE D S HI E L D F O R E AC H C AB L E E X I T C A P T IVE SE A LIN G SC R E WS S INGL E P OL E SE A LIN G WIR E FA C ILIT Y 5 WAY CONNE C T O R B O X T WO T E R MIN A L P IN C H SC R E WS FOR E A C H CABLE ENTRY US E D F OR L I V E AND NE UT R AL C O NNE C T I O N S T E R MIN A T ION B LOC K MA C H IN E D FR OM BRASS, WITH AL T E RNAT I V E L AB E L L E D C O V E R W HE N U SE D A S E A R T H BL OCK ACCEPTS 2 X 70MM 2 CABLES AT BOTTOM AND 3 X 70MM 2 S E AL ING W I R E F AC I L I T Y C A B LE S AT T OP SE R R A T E D C A B LE B OR E S

T W O T E RM I NAL P I NC H S C R E W S F O R E A C H C A B LE E N T R Y

T E RM INAT I O N B L O C K M AC HI NE D F R O M B R A SS , WIT H S E RRAT E D C AB L E B O R E S

ACCEPTS 2 X 35MM 2 CABLES AT BOTTOM AND 3 X 35MM 2 CABL E S AT T O P

MLNS6

MLNS5

MLNS5

Ref.

Description

Material

Dimensions in mm

MLNS5 MLNS6

5 way single pole connector box 6 way single pole connector box

Grey glass filled engineering thermoplastic Black phenolic thermoset

H58 W49 D42 H53 W115 D53

Ref.

Options

3mm Hex-Drive pinch screws 2

HSCO House Service Cut-out


SP/SPNE Features
A CCEP T S F US E L I NK S I N AC C O R DANC E W I T H B S 1 3 6 1 :1 9 9 1 M A X IMUM RAT I NG T Y P E I I a F US E 6 0 / 8 0 A M A X IMUM RAT I NG T Y P E I I b F US E 1 0 0 A NON INTERCHANGEABLE SOLID LINK DISCONNECTOR AVAILABLE T ES T ED AND AP P R O V E D T O B S 7 6 5 7 : 1 9 9 3 MOULDED IN LIGHT GREY GLASS REINFORCED POLYESTER DMC T HE RMOS E T M AT E R I AL S OL ID BRAS S T E R M I NAL B L O C K S W I T H S E R R A T E D B OR E S A N D T W O HE X AGON DR I V E T E R M I NAL P I NC HI N G SC R E W S P ER CONDUCT O R T W O INCOM ING AND O UT GO I NG T E R M I NA LS S H IEL DE D INCOM I NG AND O UT GO I NG P HASE P R O T E C T ION SE P A R A T E C A B LE C OVE R OR SE A LIN G CHAMBE R SA FE T Y IN T E R LOC KE D MOU LD IN G S. N O COVE R MOULDINGS C A N B E R E MOVE D U N T IL FU SE C A R R IE R OR SOLID LINK IS WIT H D R A WN . U N U SE D C A B LE E N T R Y SE A LIN G P LU G S SUP P LIE D SWIT C H WIR E P R OVISION ON N E U T R A L/E ART H BLOCK A C C E P T S C ON D U C T OR S U P T O 3 5 MM 2 R E VE R SIB LE MOU N T IN G SE A LIN G WIR E FA C ILIT Y B U SB A R FA C ILIT Y T O IN T E R C ON N E C T C UT -OUT S SP C A N B E U SE D IN C ON JU N C T ION WITH CNE CUT-OUT TO FOR M T P N E SE T

SP 100

SPNE 100

SPNE 100 with Cable Cover

TPNE 100 with Cable Cover

HSCO House Service Cut-out


SP/SPNE
TPNE 100 TPNE SC F100

Ref.

Description

Fuse rating

Dimensions in mm

SP 60/80 SP 100 SPNE 60/80 SPNE 100 SPNE L TPNE 60/80 TPNE 100

DMC SP 60/80A House Service Cut-out DMC SP 100A House Service Cut-out DMC SPNE 60/80A House Service Cut-out DMC SPNE 100A House Service Cut-out DMC SPNE Solid Link Disconnector DMC SP 60/80 + SPNE 60/80 House Service Cut-out DMC SP 100 + SPNE 100 House Service Cut-out

Type IIa 60/80A Type IIb 100A Type IIa 60/80A Type IIb 100A

H98 W44 D96 H98 W44 D96 H98 W84 D96 H98 W84 D96 H98 W84 D96

Type IIa 60/80A Type IIb 100A

H98 W180 D96 H98 W180 D96

Ref.

Accessories

Dimensions in mm

Ref.

Options

SPNE CC SPNE SC SEBL DEBL

DMC SPNE Cable Cover DMC SPNE Sealing Chamber Single Extension Busbar Link kit Double Extension Busbar Link kit

H102 W87 D42 H135 W123 D75

F60 F80 F100

Fitted with 60A Fuse link Fitted with 80A Fuse link Fitted with 100A Fuse link

TPNE CC TPNE SC

DMC TPNE Cable Cover DMC TPNE Sealing Chamber

H166 W185 D52 H165 W235 D75

Ref.

Spares

RFC80 RFC100 RDL

60/80 Replacement Fuse Carrier 100 Replacement Fuse Carrier Replacement Disconnector Link

Type IIa 60/80A Type IIb 100A

Example

TPNE 100 - TPNE SC - F100 100A TPNE HSCO with sealing chamber, fitted with 100A fuse links

HDCO Heavy Duty Cut-out


MC300 Features
A CCE P T S BS 8 8 J T Y P E F US E L I NK S

M AX IM UM R AT I NG 3 0 0 A

F US E CARRI E R W I T H 8 3 M M C E NT R E S

M OUL DE D I N W HI T E GL AS S F I L L E D P O LY E ST E R T HE RM OS E T M AT E R I AL

A LL CONT AC T S M ANUF AC T UR E D F R O M SO LI D B R A SS S E CT ION W I T H 2 T E R M I NAL P I NC HI NG SC R E WS P ER CONDUC T O R

Type 1 Clamp fitting for 35mm2 to 120mm2

Type 2 Clamp fitting for 185mm2

CABL E E NT R Y AND E X I T S T HR O UGH P VC G R O M ME T

M AX IM UM C AB L E S I Z E 1 8 5 M M 2

OP T IONAL NE UT R AL L I NK

REFER TO PAGE 14 FOR FUSE BASES, CONTACTS AND F US E HANDL E S

Type 3 Tunnel Terminal for 95mm2

MC300N

N/B

Ref.

Description

Max Fuse rating

Max cable size

Dimensions in mm

MC300
Ref.

Single Phase Heavy Duty Cut-out with fuse


Description

300A
Max Fuse rating

185mm

H162 W135 D76


Dimensions in mm

Max cable size

MC300N

Single Phase Heavy Duty Cut-out with neutral link

300A

185mm2

H162 W135 D76

Ref.

Fittings for MC300

Ref.

Fittings for MC300N

A B C H J 5

Type 2 contact Type 2/3 contact Type 3 contact Type 1 contact Type 1/3 contact

Fittings 185mm / 185mm


2 2 2

2 2 2

N/A N/B N/C N/E N/F

Type 2 contact Type 2/3 contact Type 3 contact Type 1 contact Type 1/3 contact

Fittings 185mm2 / 185mm2 Fittings 185mm2 / 2 x 95mm2 Fittings 2 x 95mm2 / 2 x 95mm2 Fittings 35-120mm2 / 35-120mm2 Fittings 35-120mm2 / 2 x 95mm2

Fittings 185mm / 2 x 95mm

Fittings 2 x 95mm / 2 x 95mm

Fittings 35-120mm2 / 35-120mm2 Fittings 35-120mm2 / 2 x 95mm2

Example

HDCO MC300N - N/B Single Phase Heavy Duty Cut-out with neutral link with fittings

HDCO Heavy Duty Cut-out


MC630 Features
ACCE P T S BS 8 8 J T Y P E F US E L I NK S M AX IM UM R AT I NG 6 3 0 A

F US E CARRI E R W I T H 9 2 M M C E NT R E S

MOULDED IN LIGHT GREY GLASS REINFORCED POLYESTER DM C

E ACH P HAS E F UL L Y I NS UL AT E D W I T H SE P A R A T E LID

WOODE N B AT T E NS P R E - DR I L L E D F O R WA LL M O U N T IN G

S INGL E P HAS E O R T HR E E P HAS E V E R S I O N S A V A ILA B LE

M AX IM UM C AB L E S I Z E 2 X 3 0 0 M M 2

CABL E E NT R Y AND E X I T T HR O UGH P VC G R O M M E T S

AL L CABL E T E R M I NAT I O NS M ANUF AC T U R E D I N H A R D DRAW N CO P P E R

COP P E R NE UT R AL L I NK S E C UR E D B Y B O LT S

INCOM ING C O NNE C T I O NS C AN B E I NSU LA T E D W H ILST T ERM INAT ING O UT GO I NG C O NNE C T I O N S

4MC630

MC630

Ref.

Description

Max Fuse rating

Max cable size

Dimensions in mm

MC630 4MC630

Single Phase Heavy Duty Cut-out Three Phase and Neutral Heavy Duty Cut-out

630A 630A

2X300mm2 2X300mm
2

H350 W120 D180 H350 W500 D195

HDCO Heavy Duty Cut-out


Insulated Single Pole Three Phase & Neutral GF Features
MOULDED IN LIGHT GREY GLASS REINFORCED POLYESTER DM C 2 00 A, 4 0 0 A O R 6 0 0 A R AT I NG ACCE P T S BS 8 8 J T Y P E F US E L I NK O N P H A SE S INCOMING CONNECTIONS CAN BE INSULATED/SHROUDED F US E CARRI E R S W I T H 8 3 M M O R 9 2 M M C E N T R E S L IF T OFF CO V E R W I T H S E C UR I T Y S E AL I N G FA C I LIT IE S A LL C A B LE T E R MIN A T ION S MA N U FA C TURE D IN HARD TWO P ART DE T AC HAB L E C AB L E T R O U G H CABL E S IZ E S : 1 2 0 M M 2 , 1 8 5 M M 2 O R 3 0 0 M M 2 THREE CABLE ENTRY POSITIONS BY EITHER BRASS GLAND OR P V C GRO M M E T CABL E E X IT B Y W O O DE N O R C L O S E D C E LL FO A M CABL E BUS H D R A WN C OP P E R SU IT A B LE FOR B OT H P ME A N D SN E A P P LICAT IONS TOP P LA T E A D A P T OR A VA ILA B LE T O C ONNE CT WITH ME T E R IN G C A B IN E T WH ILST OU T G OIN G C ON N E C T ION S A R E BE ING T E R MIN A T E D AVAILABLE WITH SHEAR HEAD MECHANICAL CONNECTORS ON IN C OMIN G OR OU T G OIN G T E R MIN ALS VA R IA B LE N E U T R A L/E A R T H T E R MIN A TIONS SOLUTIONS T O SU IT SP E C IFIE R S R E QU IR E ME N T S

GF200

GF400

GF600

HDCO Heavy Duty Cut-out


GF

GF400

LT - LT

FB

Ref.

Description

Max Fuse rating

Fuse carrier

Dimensions in mm

GF200

TPNE FUSED CUTOUT

200A

83mm centre

H425 W355 D187

Ref.

Description

Max Fuse rating

Fuse carrier

Dimensions in mm

GF400

TPNE FUSED CUTOUT

400A

83mm centre

H647 W510 D228

Ref.

Description

Max Fuse rating

Fuse carrier

Dimensions in mm

GF600

TPNE FUSED CUTOUT

600A

92mm centre

H827 W550 D258

Cable Terminations Options Ref. Incoming Outgoing

TC - TC LT - TC SMC1 - TC SMC2 - TC SMC1 - MC SMC2 - MC


Ref.

Tunnel Connector Lug Termination Shear Head Mechanical Connectors for 95mm2 cable Shear Head Mechanical Connectors for 185mm2 cable Shear Head Mechanical Connectors for 95mm cable
2

Tunnel Connector Tunnel Connector Tunnel Connector Tunnel Connector Mechanical Connector Mechanical Connector
Outgoing
TC - Tunnel Connector

Shear Head Mechanical Connectors for 185mm2 cable


Incoming

LT - LT SMC2 - LT SMC3 - LT SMC2 - MC SMC3 - MC


Ref.

Lug Termination Shear Head Mechanical Connectors for 185mm cable


2

Lug Termination Lug Termination Lug Termination Mechanical Connector Mechanical Connector
Outgoing
SMC - Shear Head Mechanical Connector LT - Lug Termination

Shear Head Mechanical Connectors for 300mm2 cable Shear Head Mechanical Connectors for 185mm2 cable Shear Head Mechanical Connectors for 300mm2 cable
Incoming

LT - LT SMC3 - LT SMC3 - MC

Lug Termination Shear Head Mechanical Connectors for 300mm2 cable Shear Head Mechanical Connectors for 300mm2 cable

Lug Termination Lug Termination Mechanical Connector

Ref.

Top Exit Plate

FB WB

Closed Cell Foam Cable Bush Wooden Cable Bush

MC - Mechanical Connector

Example

HDCO GF 400 LT - LT - FB GF400 Heavy Duty Cut-out with lug termination and cable exit by closed cell foam plate 8

HDCO
MPC400 Pole Mounted Cut-outs Features
COM P L IE S W I T H B S 7 6 5 6 : 1 9 9 3

ACCEPTS BS 88 J TYPE FUSE LINKS HAVING 83MM FIXING CENTRE

M AX IM UM F US E R AT I NG 4 0 0 A

M AX IM UM C AB L E S I Z E 1 8 5 M M 2

MOULDED IN LIGHT GREY GLASS REINFORCED POLYESTER DMC

S U PP L IE D W I T H C O AC H B O L T F O R F I X I NG T O WO OD P OLE

AV AIL ABL E W I T H C O M P R E S S I O N L UG O R SH E A R H E A D M E CHANICAL C O NNE C T O R S

F IT T E D W IT H P V C C AB L E E NT RY GR O M M E T S

Fuse Handle

MPC 400

MPC400

SMC2

Ref.

Description

Max Fuse rating

Max cable size

Dimensions in mm

MPC400

Pole mounted cut-out

400A

185mm2

H267 W140 D215

Ref.

Cable Terminations

SMC2 LT

Shear Head Mechanical Connectors for 185mm2 cable Lug Termination

HDCO
ABC Service Box Features
COM P L IE S W I T H E AT S S T ANDAR D 4 3 - 1 4

MANUFACTURED IN STRONG THERMOPLASTIC MATERIAL WITH EX T E RNAL P R O T E C T I O N T O I P 4 3

ACCE P T S CAB L E S UP T O 5 0 M M 2

UP T O 9 S E RV I C E C AB L E S B AL ANC E D O V E R T H R E E P H A SE S PROTECTED BY POLYCARBONATE COVERS AND TAGS TO SCREEN UNUS E D L IV E W AY S

S OLID BRAS S T I NNE D NE UT R AL B L O C K WI T H D E F LE C T IVE PV C COV E R

AL L T E RM INAL B L O C K S HAV E S E R R AT ED B O R E S

OUT GOING C AB L E S ( M AX I M UM 3 5 M M 2 ) E X I T T H R OU G H T OP M OUNT E D CL O S E D C E L L F O AM C AB L E B U SH

INT E RNAL P R O T E C T I O N T O I P 2 X B

S UP P L IE D AS S T ANDAR D W I T H 2 O FF 1 9 M M H E X A G ON H E A D COACH BOL T S F O R W O O DE N P O L E M O U N T I N G

S UIT ABL E F O R W AL L O R B R AC K E T M O U N T I N G

ABC Box

ABC

Ref.

Description

Max Fuse rating

Max cable size

Dimensions in mm

ABC

Aerial Bundled Conduct Service Box

200A

50mm2

H384 W390 D106

10

MSDB Multi Service Distribution Boards


Horizontal Busbar Arrangement Features
M ANUF AC T UR E D I N L I GHT GR E Y GL A SS R E I N F OR C E D POLYESTER (GF) OR 1.6MM STEEL (ST) AND PAINTED WITH E P OX Y P O W DE R E L E C T R O S T AT I C O V E N C U R E D P A IN T OUTGOING CABLES NOMINAL 35MM 2 EXIT THROUGH PVC POLYESTER STOVE ENAMELLED TEXTURED PAINT FINISHED IN ADM IRAL T Y GR E Y T O B S 3 8 1 C S HA D E N O . 6 3 2 G R OMME T S OR T H R OU G H A C LOSE D CE LL FOAM TOP P LA T E . IN SU LA T E D FR ON T SC R E E N S PROT E CT LIVE IN C OMIN G T E R MIN A LS FITTED WITH TWO PART REMOVABLE OUTER COVER AND F OUR BOS S E S F O R W AL L M O UNT I NG TE R MIN A T ION B Y C OMP R E SSION OR ME CHANICAL C ON N E C T OR S ON T O C OP P E R B U SB A R S HORIZ ONT AL B US B AR AR R ANGE M E N T SOLID B R A SS 2 P IE C E N E U T R A L/E A R T H BAR WITH LINK S E CURIT Y S E AL I NG F AC I L I T Y O N P HA SE C U T - O U T S A N D OUT E R CO V E R FA C ILIT Y A N D T U N N E L T E R MIN A T ION S HAVING 8MM D IA ME T E R T E R MIN A L P IN C H IN G SC R E WS INCOMING CABLE NOMINAL 185MM 2 ENTERING THROUGH P VC G R OMME T IN ON E OF T H R E E P O SIT IONS

INT E RIOR F I T T E D W I T H B S 7 6 5 7 : 1 9 9 3 C U T - O U T S U SIN G IIb T Y P E F US E S ( M AX I M UM R AT I NG 1 0 0 A )

E A R T H C ON N E C T ION MA N U FA C T U R ED IN HARD DRAWN C OP P E R WIT H B R A SS ST U D

3 0 0 A BUS B AR R AT I NG

C IR C U IT ID E N T IFIC A T ION /LA B E LLIN G FACILIT Y

INT E RNAL P R O T E C T I O N T O I P 2 X B

MSDB ST 16

MSDB GF 10

MSDB ST RM 12

SMC2

Ref.

Busbar Arrangement

Material

Description

No of ways

MSDB GF 7 MSDB GF 10 MSDB ST 7 MSDB ST 10 MSDB ST 16 MSDB ST RM 12 MSDB ST RM 18 MSDB ST RM 24 MSDB ST RM 30 MSDB ST RM 36 MSDB ST J 12 MSDB ST J 18 MSDB ST J 24 11 MSDB ST J 30 MSDB ST J 36

Horizontal Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical

Glass Fibre Glass Fibre Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel Steel

7 SP/N cut-out with 3 blank ways 10 SP/N cut-out 7 way SP/N cut-out 10 way SP/N cut-out 16 way SP/N cut-out MSDB for rising main MSDB for rising main MSDB for rising main MSDB for rising main MSDB for rising main Combined MSDB and J Combined MSDB and J Combined MSDB and J Combined MSDB and J Combined MSDB and J

7 10 7 10 16 12 18 24 30 36 12 18 24 30 36

MSDB Multi Service Distribution Boards


Vertical Busbar Arrangement Features
M ANUF ACT UR E D I N 1 . 6 M M S T E E L AND P A I N T E D WIT H EP OX Y P OW DE R E L E C T R O S T AT I C O V E N C U R E D P A IN T OU T G OIN G C A B LE S N OMIN A L 3 5 MM 2 EXIT E NCLOSURE T H R OU G H A C LOSE D C E LL FOA M T OP PLAT E . INSULATED FR ON T SC R E E N S P R OT E C T LIVE IN C OMING T E RMINALS POLYESTER STOVE ENAMELLED TEXTURED PAINT FINISHED IN ADM IRAL T Y GR E Y T O B S 3 8 1 C S HA D E N O . 6 3 2 C IR C U IT ID E N T IFIC A T ION /LA B E LLIN G FACILIT Y

VERT ICAL BUS B AR AR R ANGE M E NT

SOLID B R A SS N E U T R A L B LOC K

ONE P IE CE 1 . 6 M M S T E E L R E M O V AB L E C O V E R W IT H S ECURIT Y S E AL I NG F AC I L I T Y

OP T ION A L SOLID B R A SS E A R T H B LOC K

R E MOVA B LE N E U T R A L/E A R T H LIN K FA CILIT Y F OUR BOS S E S F O R W AL L M O UNT I NG AVA ILA B LE IN P ME OR SN E C ON FIG U R AT ION FITTED WITH INTERIOR BS 7657:1993 CUT-OUTS USING IIb F US E S M AX I M UM R AT I NG 1 0 0 A MSD B ST J IS A VA ILA B LE WIT H FU SE D INCOME R, MA N U FA C T U R E D IN 2 MM ST E E L ( 6 3 0 A BUSBAR RATING) 50 0 A BUS BAR R AT I NG

INT E RNAL P R O T E C T I O N T O I P 2 X B

INCOM ING C AB L E NO M I NAL 3 0 0 M M 2 EN T E R S T O P OR BOT T OM T HR O UGH P V C GR O M M E T T ER M I N A T I O N B Y COM P RE S S IO N O R M E C HANI C AL C O NNE C T O R S O N T O COP P E R BUS B AR S

MSDB ST RM 12

MSDB ST J Type

Fuse rating

Dimensions in mm

Ref.

Cable Termination Options

100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

H652 W576 D143 H652 W576 D143 H602 W392 D147 H741 W533 D147 H741 W815 D147 H1020 W457 D192 H1020 W551 D192 H1020 W645 D192 H1020 W739 D192 H1020 W833 D192 H1120 W513 D440 H1120 W607 D440 H1120 W701 D440 H1120 W795 D440 H1120 W889 D440

SMC2 SMC3 LT Example:

Shear Head Mechanical Connectors for 185mm2 cable Shear Head Mechanical Connectors for 300mm2 cable Lug Termination

MSDB ST RM 12 - SMC2 MSDB for rising main, steel material, 12 ways, and fitted with mechanical connectors for 185mm2 cables

12

Street Lighting Cut-out


SLF Single Phase Fuse Unit Features
DESIGNED, MANUFACTURED AND TESTED IN ACCORDANCE WIT H BS 7 6 5 4 : 1 9 9 7 ALL TERMINALS ARE FORMED FROM SOLID BRASS, SERRATED A N D E LE C T R OP LA T E D

M OUL DE D I N HI GH GR ADE , HI GH P E R F O R M A N C E THE RM OP L AS T I C T O B S 7 6 5 4 : 1 9 9 7

C ON D U C T OR P IN C H SC R E WS SLOT T E D OR 3 MM HEX DRIVE

MAXIMUM CABLE OF 16MM 2 STRANDED COPPER OR 25MM 2 M EE T S DE GR E E O F P R O T E C T I O N I P 2 X B E X T E R N A LLY SOLID A LU MIN IU M C ON D U C T OR S

ACCE P T S F US E L I NK S T O B S 8 8 P AR T 1, A C 1 6 TA G TYP E

C A B LE E N T R Y VIA P VC G R OMME T S A S ST ANDARD

25 A CURRE NT R AT I NG

OU T G OIN G C A B LE S E XIT B E LOW H OR IZ ONT AL T O FORM D R IP LOOP

S INGL E P OL E I S O L AT I O N SE A LIN G WIR E FA C ILIT Y AVAILABLE WITH SEPARATE NEUTRAL AND EARTH (SNE) OR COMBINED NEUTRAL/EARTH (CNE) FOR PME INSTALLATIONS C A M OP E R A T E D LE VE R ME C H A N ISM W IT H RE DUCED E XT R A C T ION FOR C E T O D ISC ON N E C T THE FUSE CARRIER S INGL E F US E

SLF SNE

Ref.

Description

Dimensions in mm

Ref.

Options

SLF SNE SLF CNE

TYPE 1 Separate Neutral & Earth TYPE 2 Combined Neutral & Earth

H150 x W76 x D61 H150 x W76 x D61

H F25 FX

3mm Hex-Drive pinch screws Fitted with 25A Fuse Link Fitted with XA (Please specify fuse rating)

13 NB: Please contact our Lucy Lighting office on 01865 311670 for the complete Street Lighting Catalogue.

Accessories
J Fuse
- Conforms to BS 88 PT6 and EA 12-10 and 12-20 - For use in LV switchgear, pole mounted cut-outs and heavy duty cut-outs - Rated Voltage: 415V a.c. - Rated breaking capacities: 80kA at 415V a.c.
Fixing Centre G 83mm 92mm Current Rating

Fuse Bases
- Accepts BS 88 J type fuse link on phases - Base mounted in phenolic - All tunnel cable terminations manufactured from solid brass section with 2 pinching screws on each conductor - All T section terminations manufactured from solid brass section - Connector pads manufactured from hard drawn copper, drilled for lug connection and suitable material for mechanical connectors
Ref. Current Rating Contact Type

JPU 63 JPU 80 JPU 100 JPU 125 JPU 160 JPU 200 JPU 250 JPU 315 JPU 355 JPU 400 (JPU 450) (JPU 500) (JPU 560) (JPU 630) -

JSU 63 JSU 80 JSU 100 JSU 125 JSU 160 JSU 200 JSU 250 JSU 315 JSU 355 JSU 400 JSU 450 JSU 500 JSU 560 JSU 630 JSU 800

63A 80A 100A* 125A 160A* 200A* 250A* 315A* 355A* 400A* 450A 500A* 560A 630A* 800A

E60 Base E150 Base E300 Base

200A 200A 400A

Tunnel T T

Fuse Handles
- Accepts BS 88 J type fuse links and fuse handle links - Handle manufactured in glass reinforced polyester - Handle operation by wedge tightening thumb screws
Ref. Design Contact centre

* BS 88: part 5: 1988 standardised current ratings (XX) restricted to intermittent loading when used in 400A contacts NB: JSU 800 fuse-links comply with BS 88: part1: 1988 and are restricted to intermittent loading when used in 630A contacts.

Handle MJW3 Handle MJW3ST Handle MJW4ST Handle PSA

Un-shrouded Shrouded Shrouded Shrouded

83mm 83mm 92mm 92mm

RH & RHL Fuse


- Conforms to BS 1361, EA 12-10 and IEC requirements - Rated Voltage: 240V a.c. - Breaking range and utilization category: gG - Rated breaking capacities: 20kA at 240V a.c.
Ref. Current Rating Dimensions in mm

Fuse Handle Links


- Manufactured in electro-plated hard drawn copper with riveted centre piece
Ref. Current Rating Contact centre

RH60 RH80 RHL60 RHL80 RHL100

Type IIa 60A Type IIa 80A Type IIb 60A Type IIb 80A Type IIb 100A

L 57 D22.23 L 57 D22.23 L 57 D30.16 L 57 D30.16 L 57 D30.16

25177 25178 25179

400A 600A 800A

83mm 92mm 92mm

Screwdriver Operated Wedge Links


- Operation by screwdriver wedge tightening - Manufactured in hard drawn copper - Wedge and tightening block manufactured from solid brass sections - Lifting lug for easy removal - Angled sides for entry guidance - Link extractor tool available
Ref. Current Rating Contact centre

Spring Bolted Links


- Operation by screwdriver wedge tightening - Manufactured in hard drawn copper - Lifting lug for easy removal - Angled sides for entry guidance - Link extractor tool available
Ref. Current Rating Contact centre

25169 25170 25171

400A 600A 800A

83mm 92mm 92mm

25160 25161 25162

400A 600A 800A

83mm 92mm 92mm 14

Lucy Switchgear Howland Road, Thame, Oxfordshire, OX9 3UJ, UK tel: +44 (0)1844 267267 fax: +44 (0)1844 267223 email: sales@lucyswitchgear.com

Lucy Middle East PO Box 17335, Jebel Ali, Dubai, United Arab Emirates tel: +9714 812 9999 fax: +9714 812 9900 email: sales@lucyme.ae

The Saudi Lucy Company Ltd PO Box 834, Al-Khobar, 31952, Saudi Arabia tel: +966 3 8823057 fax:+ 966 3 8822553 email: info@saudilucy.com

www.lucyswitchgear.com
LS00001 CO 08 2004

S-ar putea să vă placă și