45 to 55 kW
AC operated
1SBC573242F0301
Description
A95-30-00
A95 ... A110 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 / 1000 V AC or 220 V DC.
These contactors are of the block type design with:
3 main poles
control circuit: AC operated
add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
40 C
400 V
690 V
AC-3
AC-1
kW
A
45
145
55
160
UL/CSA
3-phase
motor
rating
480 V
hp
60
A
125
75
140
V 50 Hz
24
48
110
220230
230240
380400
400415
24
48
110
220230
230240
380400
400415
V 60 Hz
24
48
110120
230240
240260
400415
415440
24
48
110120
230240
240260
400415
415440
Auxiliary Type
contacts
tted
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A95-30-00
A95-30-00
A95-30-00
A95-30-00
A95-30-00
A95-30-00
A95-30-00
A110-30-00
A110-30-00
A110-30-00
A110-30-00
A110-30-00
A110-30-00
A110-30-00
Order code
Weight
Pkg
(1 pce)
1SFL431001R8100
1SFL431001R8300
1SFL431001R8400
1SFL431001R8000
1SFL431001R8800
1SFL431001R8500
1SFL431001R8600
1SFL451001R8100
1SFL451001R8300
1SFL451001R8400
1SFL451001R8000
1SFL451001R8800
1SFL451001R8500
1SFL451001R8600
kg
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
Main dimensions
mm, inches
123.5 4.86"
6.5 0.26"
5/18 | ABB
20 0.79"
1SFC101007C0201
A95, A110
10 0.39"
E0784D1
90 3.54"
E0783D
148 5.83"
6 0.24"
1SBC101374F0014
AF95-30-00
Ordering details
IEC
Rated operational
power
current
40 C
400 V
690 V
AC-3
AC-1
kW
A
45
145
UL/CSA
3-phase
motor
rating
480 V
General
use
rating
600 V AC
hp
60
A
125
55
75
140
160
V 50/60 Hz
48130
100250
48130
100250
Auxiliary Type
contacts
tted
V DC
2060
48130
100250
2060
48130
100250
0
0
0
0
0
0
0
0
0
0
0
0
AF95-30-00
AF95-30-00
AF95-30-00
AF110-30-00
AF110-30-00
AF110-30-00
Order code
Weight
Pkg
(1 pce)
1SFL437001R7200 (1)
1SFL437001R6900
1SFL437001R7000
1SFL457001R7200 (1)
1SFL457001R6900
1SFL457001R7000
kg
2.030
2.030
2.030
2.030
2.030
2.030
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
Main dimensions
mm, inches
123.5 4.86"
6.5 0.26"
1SFC101008C0201
20 0.79"
10 0.39"
E0784D1
90 3.54"
E0783D
148 5.83"
6 0.24"
AF95, AF110
ABB | 5/19
RV5/..
VE5-2
5
CA5-10
CA5-22E
A.. contactor
CAL18-11
TA
overload relay
Main
poles
A95, A110
1 to 6 x CA5-..
or 1 x CA5-.. (4-pole)
AF95, AF110
1 to 6 x CA5-..
or 1 x CA5-.. (4-pole)
1-pole CA5- ..
Side-mounted accessories
Auxiliary contact blocks
4-pole CA5- ..
2-pole CAL..
Interlock unit
VE5-2
1 to 2 x CAL18-11
or 1 x VE5-2
1 to 2 x CAL18-11
or 1 x VE5-2
+ 2 x 1-pole CA5-..
+1 x CAL18-11
+ 2 x 1-pole CA5-..
+1 x CAL18-11
1SFC101026C0201
The addition of an overload relay on the contactor does not prevent tting of many other accessories as shown above.
(1) Direct mounting - No kit required.
5/20 | ABB
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
CA5-10
1SFC101033F0201
1
2
CA5-10
CA5-01
CA5-22E
1SBN010010R1010
1SBN010010R1001
1SBN010040R1022
10
10
2
0.014
0.014
0.060
CAL18-11
1SFN010720R1011
0.050
VE5-2
1SBN030210R1000
0.146
Type
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-2/50
RC5-2/133
RC5-2/250
RC5-2/440
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050200R1000
1SBN050200R1001
1SBN050200R1002
1SBN050200R1003
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
BEA110/495
1SBN084506R1000
0.124
BEM110-30
1SFN084301R1000
0.450
1SFN094301R1000
0.600
CAL18-11
1SBC574001F0301
Surge suppressors
For contactors
02
02
01
RV5/50
NC
VE5-1, VE5-2
Terminal marking and positioning
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
AC
DC
A2
A1
A2
PN110-21
1SFC101076C0201
A1
For MS495
ABB | 5/21